Metrology & calibration
ERG95 Spółka z ograniczoną odpowiedzialnością is a calibration laboratory accredited by PCA under number AP 092 (Wrocław, Poland). Its accreditation scope covers 74 calibration items in the following areas: Metrology & calibration. Calibrated items include: Multimeters, Power network parameter meters, Calibrators, Clamp meters. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Outside of permanent location (P), Internal procedure; Direct method; At permanent location (S).
At a glance
- Accreditation number: PCA AP 092
- Calibration items in scope: 74
- Types of calibrated items: 54
- Calibration principles used: 13
- City: Wrocław, Poland
- Valid until: 18-01-2030
- Accreditation number
- AP 092
- Accreditation body
- PCA
- Address
- ul. Gen. Juliana Filipowicza 7, 52-208 Wrocław
- City
- Wrocław, Poland
- Division
- Measurement Laboratory
- Valid until
- 18-01-2030
What this laboratory calibrates (54)
- Multimeters — 10 calibration items
- Power network parameter meters — 10 calibration items
- Calibrators — 8 calibration items
- Clamp meters — 8 calibration items
- Data acquisition cards — 8 calibration items
- Power supplies — 8 calibration items
- Transmitters — 8 calibration items
- Bourdon tube pressure gauges — 6 calibration items
- Pressure transmitters — 6 calibration items
- Analogue ammeters — 4 calibration items
- Analogue voltmeters — 4 calibration items
- Barometers — 4 calibration items
- Breakdown testers — 4 calibration items
- Climatic chambers — 4 calibration items
- Digital ammeters — 4 calibration items
- and 39 more
Calibration principles (13)
- Internal procedure; At permanent location (S) — 16 calibration items
- Internal procedure; Outside of permanent location (P) — 15 calibration items
- Internal procedure; Direct method; At permanent location (S) — 9 calibration items
- Internal procedure; Direct method; Outside of permanent location (P) — 9 calibration items
- Internal procedure; Indirect method; At permanent location (S) — 7 calibration items
- Internal procedure; Indirect method; Outside of permanent location (P) — 7 calibration items
- Internal procedure; Calibration by the electrical method; At permanent location (S) — 3 calibration items
- Internal procedure; Calibration by the electrical method; Outside of permanent location (P) — 3 calibration items
- Internal procedure; Calibration and measurement. Indirect method; At permanent location (S) — 1 calibration item
- Internal procedure; Calibration and measurement. Indirect method; Outside of permanent location (P) — 1 calibration item
- Internal procedure; Calibration of the temperature measurement error only; At permanent location (S) — 1 calibration item
- Internal procedure; Direct and indirect method; At permanent location (S) — 1 calibration item
- Internal procedure; Direct and indirect method; Outside of permanent location (P) — 1 calibration item
Certificate information
- Issue date
- 16.01.2026
- Issue no.
- 25
- Certificate date
- 20.12.2024
- Accreditation cycle
- 16.01.2026 — 18.01.2030
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (74)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Transmitters | Calibration — DC voltage 0,01 mV to 100 mV · CMC 2 µV 0,1 V to 1 V · CMC 5,0·10⁻⁶ · U + 9 µV 1 V to 10 V · CMC 5,0·10⁻⁶ · U + 0,09 mV 10 V to 100 V · CMC 4,0·10⁻⁶ · U + 0,9 mV DC voltage |
Internal procedure; Direct method; At permanent location (S) | Internal procedure PT 401 | |
| 2 | Transmitters | Calibration — DC voltage 0,01 mV to 100 mV · CMC 2 µV 0,1 V to 1 V · CMC 14 µV 1 V to 10 V · CMC 0,14 mV 10 V to 100 V · CMC 1,4 mV DC voltage |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure PT 401 | |
| 3 | Multimeters Analogue voltmeters Digital voltmeters Power network parameter meters Clamp meters Data acquisition cards Breakdown testers Electronic loads |
Calibration — DC voltage 0,0001 mV to 10 mV · CMC 0,9 µV 10 mV to 100 mV · CMC 1,0·10⁻⁵ · U + 0,9 µV 0,1 V to 1 V · CMC 9,0·10⁻⁶ · U + 2 µV 1 V to 10 V · CMC 9,0·10⁻⁶ · U + 7 µV 10 V to 100 V · CMC 7,0·10⁻⁶ · U + 0,095 mV 100 V to 1050 V · CMC 5,0·10⁻⁶ · U + 1 mV DC voltage |
Internal procedure; At permanent location (S) | Internal procedure PT 402 based on EURAMET cg-15 v. 3.0 | |
| 4 | Multimeters Analogue voltmeters Digital voltmeters Power network parameter meters Clamp meters Data acquisition cards Breakdown testers Electronic loads |
Calibration — DC voltage 0,001 mV to 100 mV · CMC 1,9 µV 0,1 V to 1 V · CMC 11 µV 1 V to 10 V · CMC 0,11 mV 10 V to 100 V · CMC 0,92 mV 100 V to 1050 V · CMC 12 mV DC voltage |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 402 based on EURAMET cg-15 v. 3.0 | |
| 5 | Calibrators Power supplies |
Calibration — DC voltage 0,0001 mV to 10 mV · CMC 0,9 µV 10 mV to 100 mV · CMC 1,0·10⁻⁵ · U + 0,9 µV 0,1 V to 1 V · CMC 9,0·10⁻⁶ · U + 2 µV 1 V to 10 V · CMC 9,0·10⁻⁶ · U + 7 µV 10 V to 100 V · CMC 7,0·10⁻⁶ · U + 0,095 mV 100 V to 1050 V · CMC 5,0·10⁻⁶ · U + 1 mV DC voltage |
Internal procedure; At permanent location (S) | Internal procedure PT 403 based on EURAMET cg-15 v. 3.0 | |
| 6 | Calibrators Power supplies |
Calibration — DC voltage 0,001 mV to 100 mV · CMC 1,9 µV 0,1 V to 1 V · CMC 11 µV 1 V to 10 V · CMC 0,11 mV 10 V to 100 V · CMC 0,92 mV 100 V to 1050 V · CMC 12 mV DC voltage |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 403 based on EURAMET cg-15 v. 3.0 | |
| 7 | Transmitters | Calibration — DC current 0,1 µA to 100 µA · CMC 1,2·10⁻⁴ · I + 4 nA 0,1 mA to 1 mA · CMC 6,0·10⁻⁵ · I + 11 nA 1 mA to 10 mA · CMC 6,0·10⁻⁵ · I + 0,15 µA 10 mA to 100 mA · CMC 6,0·10⁻⁵ · I + 1,2 µA 0,1 A to 1 A · CMC 1,6·10⁻⁴ · I + 1 µA 1 A to 3 A · CMC 1,0·10⁻⁴ · I + 0,07 mA 3 A to 10 A · CMC 5,0·10⁻⁴ · I + 0,04 mA DC current |
Internal procedure; Direct method; At permanent location (S) | Internal procedure PT 401 | |
| 8 | Transmitters | Calibration — DC current 0,001 mA to 20 mA · CMC 3,5·10⁻⁴ · I + 1,2 µA 20 mA to 200 mA · CMC 3,5·10⁻⁴ · I + 12 µA 0,2 A to 2 A · CMC 3,5·10⁻⁴ · I + 0,2 mA 2 A to 10 A · CMC 3,5·10⁻⁴ · I + 1,2 mA DC current |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure PT 401 | |
| 9 | Multimeters Analogue ammeters Digital ammeters Power network parameter meters Data acquisition cards Electronic loads |
Calibration — DC current 0,1 µA to 100 µA · CMC 1,2·10⁻⁴ · I + 4 nA 0,1 mA to 1 mA · CMC 6,0·10⁻⁵ · I + 11 nA 1 mA to 10 mA · CMC 6,0·10⁻⁵ · I + 0,15 µA 10 mA to 100 mA · CMC 6,0·10⁻⁵ · I + 1,2 µA 0,1 A to 1 A · CMC 1,6·10⁻⁴ · I + 1 µA 1 A to 3 A · CMC 1,0·10⁻⁴ · I + 0,07 mA 3 A to 10 A · CMC 5,0·10⁻⁴ · I + 0,04 mA DC current |
Internal procedure; At permanent location (S) | Internal procedure PT 402 based on EURAMET cg-15 v. 3.0 | |
| 10 | Multimeters Analogue ammeters Digital ammeters Power network parameter meters Data acquisition cards Electronic loads |
Calibration — DC current 0,001 mA to 20 mA · CMC 3,5·10⁻⁴ · I + 1,2 µA 20 mA to 200 mA · CMC 3,5·10⁻⁴ · I + 12 µA 0,2 A to 2 A · CMC 3,5·10⁻⁴ · I + 0,2 mA 2 A to 10 A · CMC 3,5·10⁻⁴ · I + 1,2 mA DC current |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 402 based on EURAMET cg-15 v. 3.0 | |
| 11 | Clamp meters | Calibration — DC current 0,1 A to 1 A · CMC 0,14 mA 1 A to 10 A · CMC 1,4 mA 10 A to 100 A · CMC 2,4·10⁻³ · I + 0,4 A 100 A to 1000 A · CMC 7,0·10⁻⁴ · I + 1,2 A DC current |
Internal procedure; At permanent location (S) | Internal procedure PT 402 based on EURAMET cg-15 v. 3.0 | |
| 12 | Clamp meters | Calibration — DC current 2 A to 20 A · CMC 2 mA 20 A to 1000 A · CMC 7,0·10⁻⁴ · I + 1,2 A DC current |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 402 based on EURAMET cg-15 v. 3.0 | |
| 13 | Calibrators Power supplies |
Calibration — DC current 0,1 µA to 100 µA · CMC 1,2·10⁻⁴ · I + 4 nA 0,1 mA to 1 mA · CMC 6,0·10⁻⁵ · I + 11 nA 1 mA to 10 mA · CMC 6,0·10⁻⁵ · I + 0,15 µA 10 mA to 100 mA · CMC 6,0·10⁻⁵ · I + 1,2 µA 0,1 A to 1 A · CMC 1,6·10⁻⁴ · I + 1 µA 1 A to 3 A · CMC 1,0·10⁻⁴ · I + 0,07 mA 3 A to 10 A · CMC 5,0·10⁻⁴ · I + 0,04 mA 10 A to 200 A · CMC 4,0·10⁻⁴ · I + 5 mA DC current |
Internal procedure; At permanent location (S) | Internal procedure PT 403 based on EURAMET cg-15 v. 3.0 | |
| 14 | Calibrators Power supplies |
Calibration — DC current 0,001 mA to 20 mA · CMC 3,5·10⁻⁴ · I + 1,2 µA 20 mA to 200 mA · CMC 3,5·10⁻⁴ · I + 12 µA 0,2 A to 2 A · CMC 3,5·10⁻⁴ · I + 0,2 mA 2 A to 10 A · CMC 3,5·10⁻⁴ · I + 1,2 mA 10 A to 200 A · CMC 4,0·10⁻⁴ · I + 5 mA DC current |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 403 based on EURAMET cg-15 v. 3.0 | |
| 15 | Multimeters Clamp meters Analogue voltmeters Digital voltmeters Leakage current meters Power network parameter meters Breakdown voltage meters Residual current device testers Breakdown testers Data acquisition cards |
Calibration — AC voltage 40 Hz to 5000 Hz — 0,1 mV to 10 mV · CMC 9 µV 40 Hz to 5000 Hz — 10 mV to 100 mV · CMC 1,1·10⁻⁴ · U + 8 µV 40 Hz to 5000 Hz — 0,1 V to 1 V · CMC 6,0·10⁻⁵ · U + 0,03 mV 40 Hz to 5000 Hz — 1 V to 10 V · CMC 1,1·10⁻⁴ · U + 0,07 mV 40 Hz to 5000 Hz — 10 V to 100 V · CMC 1,2·10⁻⁴ · U + 0,7 mV 40 Hz to 5000 Hz — 100 V to 1050 V · CMC 9,0·10⁻⁵ · U + 9 mV 5 kHz to 20 kHz — 0,1 mV to 100 mV · CMC 3,0·10⁻⁴ · U + 7 µV 5 kHz to 20 kHz — 0,1 V to 1 V · CMC 6,0·10⁻⁵ · U + 0,04 mV 5 kHz to 20 kHz — 1 V to 10 V · CMC 1,1·10⁻⁴ · U + 0,07 mV 5 kHz to 20 kHz — 10 V to 110 V · CMC 1,2·10⁻⁴ · U + 0,7 mV 20 kHz to 50 kHz — 0,1 mV to 100 mV · CMC 7,0·10⁻⁴ · U + 8 µV 20 kHz to 50 kHz — 0,1 V to 1 V · CMC 1,0·10⁻⁴ · U + 0,07 mV 20 kHz to 50 kHz — 1 V to 10 V · CMC 0,044 % AC voltage |
Internal procedure; At permanent location (S) | Internal procedure PT 402 based on EURAMET cg-15 v. 3.0 | |
| 16 | Multimeters Clamp meters Analogue voltmeters Digital voltmeters Leakage current meters Power network parameter meters Breakdown voltage meters Residual current device testers Breakdown testers Data acquisition cards |
Calibration — AC voltage 40 Hz to 5000 Hz — 0,1 mV to 200 mV · CMC 7,0·10⁻³ · U + 0,05 mV 40 Hz to 5000 Hz — 0,2 V to 2 V · CMC 1,2·10⁻³ · U + 0,5 mV 40 Hz to 5000 Hz — 2 V to 20 V · CMC 1,2·10⁻³ · U + 5 mV 40 Hz to 5000 Hz — 20 V to 200 V · CMC 1,2·10⁻³ · U + 0,05 V 40 Hz to 2000 Hz — 200 V to 1050 V · CMC 1,2·10⁻³ · U + 0,24 V AC voltage |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 402 based on EURAMET cg-15 v. 3.0 | |
| 17 | Calibrators Generators Power supplies |
Calibration — AC voltage 40 Hz to 5000 Hz — 0,1 mV to 10 mV · CMC 9 µV 40 Hz to 5000 Hz — 10 mV to 100 mV · CMC 1,1·10⁻⁴ · U + 8 µV 40 Hz to 5000 Hz — 0,1 V to 1 V · CMC 6,0·10⁻⁵ · U + 0,03 mV 40 Hz to 5000 Hz — 1 V to 10 V · CMC 1,1·10⁻⁴ · U + 0,07 mV 40 Hz to 5000 Hz — 10 V to 100 V · CMC 1,2·10⁻⁴ · U + 0,7 mV 40 Hz to 5000 Hz — 100 V to 1050 V · CMC 9,0·10⁻⁵ · U + 9 mV 5 kHz to 20 kHz — 0,1 mV to 100 mV · CMC 3,0·10⁻⁴ · U + 7 µV 5 kHz to 20 kHz — 0,1 V to 1 V · CMC 6,0·10⁻⁵ · U + 0,04 mV 5 kHz to 20 kHz — 1 V to 10 V · CMC 1,1·10⁻⁴ · U + 0,07 mV 5 kHz to 20 kHz — 10 V to 110 V · CMC 1,2·10⁻⁴ · U + 0,7 mV 20 kHz to 50 kHz — 0,1 mV to 100 mV · CMC 7,0·10⁻⁴ · U + 8 µV 20 kHz to 50 kHz — 0,1 V to 1 V · CMC 1,0·10⁻⁴ · U + 0,07 mV 20 kHz to 50 kHz — 1 V to 10 V · CMC 0,044 % AC voltage |
Internal procedure; At permanent location (S) | Internal procedure PT 403 based on EURAMET cg-15 v. 3.0 | |
| 18 | Calibrators Generators Power supplies |
Calibration — AC voltage 40 Hz to 5000 Hz — 0,1 mV to 200 mV · CMC 1,2·10⁻³ · U + 0,05 mV 40 Hz to 5000 Hz — 0,2 V to 2 V · CMC 1,2·10⁻³ · U + 0,5 mV 40 Hz to 5000 Hz — 2 V to 20 V · CMC 1,2·10⁻³ · U + 5 mV 40 Hz to 5000 Hz — 20 V to 200 V · CMC 1,2·10⁻³ · U + 0,05 V 40 Hz to 2000 Hz — 200 V to 1050 V · CMC 1,2·10⁻³ · U + 0,24 V AC voltage |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 403 based on EURAMET cg-15 v. 3.0 | |
| 19 | Multimeters Analogue ammeters Digital ammeters Leakage current meters Leakage current simulators Power network parameter meters Residual current device testers Data acquisition cards |
Calibration — AC current 40 Hz to 5000 Hz — 10 µA to 100 µA · CMC 1,7·10⁻⁴ · I + 19 nA 40 Hz to 5000 Hz — 0,1 mA to 1 mA · CMC 2,7·10⁻⁴ · I + 0,02 µA 40 Hz to 5000 Hz — 1 mA to 10 mA · CMC 2,7·10⁻⁴ · I + 0,14 µA 40 Hz to 5000 Hz — 10 mA to 100 mA · CMC 2,7·10⁻⁴ · I + 1,4 µA 40 Hz to 5000 Hz — 0,1 A to 1 A · CMC 0,075 % 40 Hz to 5000 Hz — 1 A to 10 A · CMC 0,12 % AC current |
Internal procedure; At permanent location (S) | Internal procedure PT 402 based on EURAMET cg-15 v. 3.0 | |
| 20 | Multimeters Analogue ammeters Digital ammeters Leakage current meters Leakage current simulators Power network parameter meters Residual current device testers Data acquisition cards |
Calibration — AC current 40 Hz to 5000 Hz — 0,1 mA to 20 mA · CMC 2 µA 40 Hz to 5000 Hz — 20 mA to 200 mA · CMC 0,02 mA 40 Hz to 5000 Hz — 0,2 A to 2 A · CMC 0,15 mA 40 Hz to 5000 Hz — 2 A to 10 A · CMC 1 mA AC current |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 402 based on EURAMET cg-15 v. 3.0 | |
| 21 | Clamp meters | Calibration — AC current 45 Hz to 400 Hz — 0,1 A to 1 A · CMC 0,14 mA 45 Hz to 400 Hz — 1 A to 10 A · CMC 1,4 mA 45 Hz to 400 Hz — 10 A to 100 A · CMC 2,4·10⁻³ · I + 0,4 A 45 Hz to 400 Hz — 100 A to 1000 A · CMC 7,0·10⁻⁴ · I + 1,2 A AC current |
Internal procedure; At permanent location (S) | Internal procedure PT 402 based on EURAMET cg-15 v. 3.0 | |
| 22 | Clamp meters | Calibration — AC current 45 Hz to 400 Hz — 2 A to 20 A · CMC 2 mA 45 Hz to 400 Hz — 20 A to 1000 A · CMC 7,0·10⁻⁴ · I + 1,2 A AC current |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 402 based on EURAMET cg-15 v. 3.0 | |
| 23 | Calibrators Generators Power supplies |
Calibration — AC current 40 Hz to 5000 Hz — 10 µA to 100 µA · CMC 1,7·10⁻⁴ · I + 19 nA 40 Hz to 5000 Hz — 0,1 mA to 1 mA · CMC 2,7·10⁻⁴ · I + 0,02 µA 40 Hz to 5000 Hz — 1 mA to 10 mA · CMC 2,7·10⁻⁴ · I + 0,14 µA 40 Hz to 5000 Hz — 10 mA to 100 mA · CMC 2,7·10⁻⁴ · I + 1,4 µA 40 Hz to 5000 Hz — 0,1 A to 1 A · CMC 0,075 % 40 Hz to 5000 Hz — 1 A to 10 A · CMC 0,12 % AC current |
Internal procedure; At permanent location (S) | Internal procedure PT 403 based on EURAMET cg-15 v. 3.0 | |
| 24 | Calibrators Generators Power supplies |
Calibration — AC current 40 Hz to 5000 Hz — 0,1 mA to 20 mA · CMC 2 µA 40 Hz to 5000 Hz — 20 mA to 200 mA · CMC 0,02 mA 40 Hz to 5000 Hz — 0,2 A to 2 A · CMC 0,15 mA 40 Hz to 5000 Hz — 2 A to 10 A · CMC 1 mA AC current |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 403 based on EURAMET cg-15 v. 3.0 | |
| 25 | Analogue ohmmeters Digital ohmmeters Multimeters Transmitters |
Calibration — DC resistance 0,001 Ω to 1 Ω · CMC 2,0·10⁻⁵ · R + 0,6 µΩ 1 Ω to 10 Ω · CMC 2,0·10⁻⁵ · R + 1 µΩ 10 Ω to 100 Ω · CMC 2,0·10⁻⁵ · R + 0,01 mΩ 0,1 kΩ to 1 kΩ · CMC 0,002 % 1 kΩ to 10 kΩ · CMC 0,003 % 10 kΩ to 100 kΩ · CMC 0,003 % 0,1 MΩ to 1 MΩ · CMC 0,004 % 1 MΩ to 10 MΩ · CMC 0,008 % 10 MΩ to 100 MΩ · CMC 0,07 % 0,1 GΩ to 100 GΩ · CMC 0,6 % DC resistance |
Internal procedure; Direct method; At permanent location (S) | Internal procedure PT 401 | |
| 26 | Analogue ohmmeters Digital ohmmeters Multimeters Transmitters |
Calibration — DC resistance 0,001 Ω to 100 Ω · CMC 1,2·10⁻⁴ · R + 0,005 Ω 0,1 kΩ to 1 kΩ · CMC 0,023 % 1 kΩ to 10 kΩ · CMC 0,023 % 10 kΩ to 100 kΩ · CMC 0,023 % 0,1 MΩ to 1 MΩ · CMC 0,023 % 1 MΩ to 10 MΩ · CMC 0,06 % 10 MΩ to 100 MΩ · CMC 0,4 % 0,1 GΩ to 100 GΩ · CMC 1,8 % DC resistance |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure PT 401 | |
| 27 | Resistance calibrators Power network parameter meters Insulation resistance meters |
Calibration — DC resistance 0,001 Ω to 1 Ω · CMC 2,0·10⁻⁵ · R + 0,6 µΩ 1 Ω to 10 Ω · CMC 2,0·10⁻⁵ · R + 1 µΩ 10 Ω to 100 Ω · CMC 2,0·10⁻⁵ · R + 0,01 mΩ 0,1 kΩ to 1 kΩ · CMC 0,002 % 1 kΩ to 10 kΩ · CMC 0,003 % 10 kΩ to 100 kΩ · CMC 0,003 % 0,1 MΩ to 1 MΩ · CMC 0,004 % 1 MΩ to 10 MΩ · CMC 0,008 % 10 MΩ to 100 MΩ · CMC 0,07 % 0,1 GΩ to 100 GΩ · CMC 0,6 % DC resistance |
Internal procedure; At permanent location (S) | Internal procedure PT 402, PT 403 based on EURAMET cg-15 v. 3.0 | |
| 28 | Resistance calibrators Power network parameter meters Insulation resistance meters |
Calibration — DC resistance 0,001 Ω to 100 Ω · CMC 1,2·10⁻⁴ · R + 0,005 Ω 0,1 kΩ to 1 kΩ · CMC 0,023 % 1 kΩ to 10 kΩ · CMC 0,023 % 10 kΩ to 100 kΩ · CMC 0,023 % 0,1 MΩ to 1 MΩ · CMC 0,023 % 1 MΩ to 10 MΩ · CMC 0,06 % 10 MΩ to 100 MΩ · CMC 0,4 % 0,1 GΩ to 100 GΩ · CMC 1,8 % DC resistance |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 402, PT 403 based on EURAMET cg-15 v. 3.0 | |
| 29 | Fixed resistors Variable resistors Resistance standards Shunts |
Calibration — DC resistance 0,001 Ω to 0,1 Ω · CMC 5,0·10⁻³ · R + 0,1 µΩ 0,1 Ω to 10 Ω · CMC 6,0·10⁻⁵ · R + 0,02 mΩ 10 Ω to 100 Ω · CMC 6,0·10⁻⁵ · R + 0,3 mΩ 0,1 kΩ to 1 kΩ · CMC 6,0·10⁻⁵ · R 1 kΩ to 10 kΩ · CMC 6,0·10⁻⁵ · R 10 kΩ to 100 kΩ · CMC 6,0·10⁻⁵ · R 0,1 MΩ to 1 MΩ · CMC 7,0·10⁻⁵ · R 1 MΩ to 10 MΩ · CMC 1,0·10⁻⁴ · R 10 MΩ to 100 MΩ · CMC 6,0·10⁻⁴ · R 100 MΩ to 1000 MΩ · CMC 2,0·10⁻³ · R 1 GΩ to 2 GΩ · CMC 2,0·10⁻³ · R 2 GΩ to 20 GΩ · CMC 5,0·10⁻³ · R 20 GΩ to 100 GΩ · CMC 5,0·10⁻³ · R DC resistance |
Internal procedure; Direct and indirect method; At permanent location (S) | Internal procedure PT 404 | |
| 30 | Fixed resistors Variable resistors Resistance standards Shunts |
Calibration — DC resistance 0,001 Ω to 0,1 Ω · CMC 5,0·10⁻³ · R + 0,1 µΩ 0,1 Ω to 10 Ω · CMC 6,0·10⁻⁵ · R + 0,02 mΩ 10 Ω to 100 Ω · CMC 6,0·10⁻⁵ · R + 0,3 mΩ 0,1 kΩ to 1 kΩ · CMC 6,0·10⁻⁵ · R 1 kΩ to 10 kΩ · CMC 6,0·10⁻⁵ · R 10 kΩ to 100 kΩ · CMC 6,0·10⁻⁵ · R 0,1 MΩ to 1 MΩ · CMC 7,0·10⁻⁵ · R 1 MΩ to 10 MΩ · CMC 1,0·10⁻⁴ · R 10 MΩ to 100 MΩ · CMC 6,0·10⁻⁴ · R 100 MΩ to 1000 MΩ · CMC 2,0·10⁻³ · R DC resistance |
Internal procedure; Direct and indirect method; Outside of permanent location (P) | Internal procedure PT 404 | |
| 31 | Temperature transmitters | Calibration — Electrical simulation of quantities -200 °C to 850 °C · CMC 0,07 oC -200 °C do 1820 °C · CMC 0,24 oC Electrical simulation of quantities |
Internal procedure; Calibration by the electrical method; At permanent location (S) | Internal procedure PT 401 | |
| 32 | Temperature transmitters | Calibration — Electrical simulation of quantities -200 °C to 850 °C · CMC 0,36 °C -200 °C do 1820 °C · CMC 0,98 °C Electrical simulation of quantities |
Internal procedure; Calibration by the electrical method; Outside of permanent location (P) | Internal procedure PT 401 | |
| 33 | Temperature indicators (meters) (including temperature controllers) Temperature recorders |
Calibration — Electrical simulation of quantities -200 °C to 850 °C · CMC 0,07 °C -200 °C do 1820 °C · CMC 0,24 °C Electrical simulation of quantities |
Internal procedure; Calibration by the electrical method; At permanent location (S) | Internal procedure PT 402 | |
| 34 | Temperature indicators (meters) (including temperature controllers) Temperature recorders |
Calibration — Electrical simulation of quantities -200 °C to 850 °C · CMC 0,36 °C -200 °C do 1820 °C · CMC 0,98 °C Electrical simulation of quantities |
Internal procedure; Calibration by the electrical method; Outside of permanent location (P) | Internal procedure PT 402 | |
| 35 | Temperature simulators | Calibration — Electrical simulation of quantities -200 °C to 850 °C · CMC 0,07 oC -200 °C do 1820 °C · CMC 0,24 oC Electrical simulation of quantities |
Internal procedure; Calibration by the electrical method; At permanent location (S) | Internal procedure PT 403 | |
| 36 | Temperature simulators | Calibration — Electrical simulation of quantities -200 °C to 850 °C · CMC 0,36 oC -200 °C do do 1820 °C · CMC 0,98 oC Electrical simulation of quantities |
Internal procedure; Calibration by the electrical method; Outside of permanent location (P) | Internal procedure PT 403 | |
| 37 | Transmitters | Calibration — Relative humidity zakres temperatur 5 °C to 60 °C — 10 %rh to 90 %rh · CMC 2,0 %rh Relative humidity |
Internal procedure; Direct method; At permanent location (S) | Internal procedure PT 501 | |
| 38 | Transmitters | Calibration — Relative humidity zakres temperatur 5 °C to 60 °C — 10 %rh to 90 %rh · CMC 3,0 %rh Relative humidity |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure PT 501 | |
| 39 | Hygrometers Thermohygrometers Thermohygrobarometers |
Calibration — Relative humidity zakres temperatur 5 °C to 60 °C — 10 %rh to 90 %rh · CMC 1,7 %rh Relative humidity |
Internal procedure; Direct method; At permanent location (S) | Internal procedure PT 502 | |
| 40 | Hygrometers Thermohygrometers Thermohygrobarometers |
Calibration — Relative humidity zakres temperatur 5 °C to 60 °C — 10 %rh to 90 %rh · CMC 3,0 %rh Relative humidity |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure PT 502 | |
| 41 | Climatic chambers | Calibration — Relative humidity zakres temperatur 5 °C to 60 °C — 10 % to 90 %rh · CMC 2,5 %rh Relative humidity |
Internal procedure; Direct method; At permanent location (S) | Internal procedure PT 503 based on EURAMET cg-20 v. 5.0 | |
| 42 | Climatic chambers | Calibration — Relative humidity zakres temperatur 5 °C to 60 °C — 10 %rh to 90 %rh · CMC 3,0 %rh Relative humidity |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure PT 503 based on EURAMET cg-20 v. 5.0 | |
| 43 | Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters |
Calibration — Pressure - gauge pressure, negative and positive pressure (gas) — -0,1 MPa to -0,03 MPa · CMC 3,0·10⁻⁵ MPa - gauge pressure, negative and positive pressure (gas) — -0,03 MPa to -0,0024 MPa · CMC 1,1·10⁻⁵ MPa - gauge pressure, negative and positive pressure (gas) — -0,0024 MPa to 0,0024 MPa · CMC 2,0·10⁻⁶ MPa - gauge pressure, negative and positive pressure (gas) — 0,0024 MPa to 0,01 MPa · CMC 6,2·10⁻⁶ MPa - gauge pressure, negative and positive pressure (gas) — 0,01 MPa to 0,03 MPa · CMC 1,1·10⁻⁵ MPa - gauge pressure, negative and positive pressure (gas) — 0,03 MPa to 0,2 MPa · CMC 4,4·10⁻⁵ MPa - gauge pressure, negative and positive pressure (gas) — 0,2 MPa to 1,8 MPa · CMC 6·10⁻⁶ P + 0,0002 MPa Pressure |
Internal procedure; At permanent location (S) | Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0 | |
| 44 | Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters |
Calibration — Pressure - gauge pressure, negative and positive pressure (gas) — -0,1 MPa to -0,005 MPa · CMC 1,2·10⁻⁴ MPa - gauge pressure, negative and positive pressure (gas) — -0,005 MPa to 0 MPa · CMC 5,5·10⁻⁵ MPa - gauge pressure, negative and positive pressure (gas) — 0 MPa to 0,002 MPa · CMC 0,6·10⁻⁵ MPa - gauge pressure, negative and positive pressure (gas) — 0,002 MPa to 0,005 MPa · CMC 5,5·10⁻⁵ MPa - gauge pressure, negative and positive pressure (gas) — 0,005 MPa to 0,3 MPa · CMC 1,2·10⁻⁴ MPa - gauge pressure, negative and positive pressure (gas) — 0,3 MPa to 1,0 MPa · CMC 1,2·10⁻³ MPa Pressure |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0 | |
| 45 | Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters |
Calibration — Pressure - gauge pressure, negative and positive pressure (liquid) — 0 MPa to 0,1 MPa · CMC 3,4·10⁻⁵ MPa - gauge pressure, negative and positive pressure (liquid) — 0,1 MPa to 0,6 MPa · CMC 6,3·10⁻⁵ MPa - gauge pressure, negative and positive pressure (liquid) — 0,6 MPa to 2,0 MPa · CMC 6·10⁻⁶ · P + 0,0002 MPa - gauge pressure, negative and positive pressure (liquid) — 2,0 MPa to 70,0 MPa · CMC 3·10⁻⁶ · P + 0,002 MPa Pressure |
Internal procedure; At permanent location (S) | Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0 | |
| 46 | Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters |
Calibration — Pressure - gauge pressure, negative and positive pressure (liquid) — 0 MPa to 1,0 MPa · CMC 2,3·10⁻⁴ MPa - gauge pressure, negative and positive pressure (liquid) — 1,0 MPa to 3,0 MPa · CMC 4,7·10⁻⁴ MPa - gauge pressure, negative and positive pressure (liquid) — 3,0 MPa to 10,0 MPa · CMC 2,3·10⁻³ MPa - gauge pressure, negative and positive pressure (liquid) — 10,0 MPa to 30,0 MPa · CMC 4,7·10⁻³ MPa - gauge pressure, negative and positive pressure (liquid) — 30,0 MPa to 70,0 MPa · CMC 1,0·10⁻² MPa Pressure |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0 | |
| 47 | Bourdon tube pressure gauges Electronic pressure gauges (including barometers) Pressure transmitters Barometers |
Calibration — Pressure - absolute pressure — 0,0015 MPa abs to 0,12 MPa abs · CMC 1,5·10⁻⁴ MPa - absolute pressure — 0,12 MPa abs to 0,3 MPa abs · CMC 1,8·10⁻⁴ MPa - absolute pressure — 0,3 MPa abs to 0,6 MPa abs · CMC 2,0·10⁻⁴ MPa - absolute pressure — 0,6 MPa abs to 1,0 MPa abs · CMC 2,3·10⁻⁴ MPa - absolute pressure — 1,0 MPa abs to 3,0 MPa abs · CMC 4,7·10⁻⁴ MPa Pressure |
Internal procedure; At permanent location (S) | Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0 | |
| 48 | Bourdon tube pressure gauges Electronic pressure gauges (including barometers) Pressure transmitters Barometers |
Calibration — Pressure - absolute pressure — 0,0015 MPa abs to 0,3 MPa abs · CMC 2,4·10⁻⁴ MPa - absolute pressure — 0,3 MPa abs to 1,0 MPa abs · CMC 6,0·10⁻⁴ MPa - absolute pressure — 1,0 MPa abs to 3,0 MPa abs · CMC 1,8·10⁻³ MPa Pressure |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0 | |
| 49 | Barometers | Calibration — Pressure - absolute pressure — 300 hPa abs to 1200 hPa abs · CMC 1,5 hPa Pressure |
Internal procedure; At permanent location (S) | Internal procedure PT 302 based on EURAMET cg-17 v. 4.0 | |
| 50 | Barometers | Calibration — Pressure - absolute pressure — 300 hPa abs to 1200 hPa abs · CMC 2,4 hPa Pressure |
Internal procedure; Outside of permanent location (P) | Internal procedure PT 302 based on EURAMET cg-17 v. 4.0 | |
| 51 | Resistance thermometer sensors | Calibration — Temperature (electrical thermometry) -100 °C do 100 °C · CMC 0,03 °C 100 °C to 200 °C · CMC 0,05 °C 200 °C do 650 °C · CMC 0,15 °C Temperature (electrical thermometry) |
Internal procedure; Indirect method; At permanent location (S) | Internal procedure PT 201 | |
| 52 | Resistance thermometer sensors | Calibration — Temperature (electrical thermometry) -35 °C to 150 °C · CMC 0,05 °C 150 °C to 650 °C · CMC 0,15 °C Temperature (electrical thermometry) |
Internal procedure; Indirect method; Outside of permanent location (P) | Internal procedure PT 201 | |
| 53 | Noble metal thermocouples Base metal thermocouples |
Calibration — Temperature (electrical thermometry) -100 °C do 100 °C · CMC 0,3 °C 100 °C to 200 °C · CMC 0,4 °C 200 °C do 650 °C · CMC 0,5 °C 650 °C do 1085 °C · CMC 0,7 °C 1085 °C to 1200 °C · CMC 1,2 °C Temperature (electrical thermometry) |
Internal procedure; Indirect method; At permanent location (S) | Internal procedure PT 201 based on EURAMET cg-8 v. 3.1 | |
| 54 | Noble metal thermocouples Base metal thermocouples |
Calibration — Temperature (electrical thermometry) -35 °C do 150 °C · CMC 0,5 °C 150 °C do 650 °C · CMC 0,7 °C 650 °C do 1085 °C · CMC 1,0 °C 1085 °C to 1200 °C · CMC 1,5 °C Temperature (electrical thermometry) |
Internal procedure; Indirect method; Outside of permanent location (P) | Internal procedure PT 201 based on EURAMET cg-8 v. 3.1 | |
| 55 | Temperature transmitters (with temperature sensor) | Calibration — Temperature (electrical thermometry) -100 °C do 100 °C · CMC 0,03 °C 100 °C to 200 °C · CMC 0,05 °C 200 °C do 650 °C · CMC 0,15 °C 650 °C do 1085 °C · CMC 0,7 °C 1085 °C to 1200 °C · CMC 1,2 °C Temperature (electrical thermometry) |
Internal procedure; Indirect method; At permanent location (S) | Internal procedure PT 202 | |
| 56 | Temperature transmitters (with temperature sensor) | Calibration — Temperature (electrical thermometry) -35 °C do 150 °C · CMC 0,1 °C 150 °C do 650 °C · CMC 0,2 °C 650 °C do 1085 °C · CMC 0,7 °C 1085 °C to 1200 °C · CMC 1,2 °C Temperature (electrical thermometry) |
Internal procedure; Indirect method; Outside of permanent location (P) | Internal procedure PT 202 | |
| 57 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) |
Calibration — Temperature (electrical thermometry) -100 °C do 100 °C · CMC 0,03 °C 100 °C to 200 °C · CMC 0,05 °C 200 °C do 650 °C · CMC 0,15 °C 650 °C do 1085 °C · CMC 0,7 °C 1085 °C to 1200 °C · CMC 1,2 °C Temperature (electrical thermometry) |
Internal procedure; Indirect method; At permanent location (S) | Internal procedure PT 203 | |
| 58 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) |
Calibration — Temperature (electrical thermometry) -35 °C do 150 °C · CMC 0,1 °C 150 °C do 650 °C · CMC 0,2 °C 650 °C do 1085 °C · CMC 0,7 °C 1085 °C to 1200 °C · CMC 1,2 °C Temperature (electrical thermometry) |
Internal procedure; Indirect method; Outside of permanent location (P) | Internal procedure PT 203 | |
| 59 | Liquid baths | Calibration — Temperature (electrical thermometry) -100 °C to 100 °C · CMC 0,02 °C 100 °C to 250 °C · CMC 0,03 °C Temperature (electrical thermometry) |
Internal procedure; Indirect method; At permanent location (S) | Internal procedure PT 206 | |
| 60 | Liquid baths | Calibration — Temperature (electrical thermometry) -100 °C to 250 °C · CMC 0,03 °C Temperature (electrical thermometry) |
Internal procedure; Indirect method; Outside of permanent location (P) | Internal procedure PT 206 | |
| 61 | Thermostatic chambers | Calibration — Temperature (electrical thermometry) -100 °C do 100 °C · CMC 0,05 °C 100 °C to 200 °C · CMC 0,1 °C 200 °C to 400 °C · CMC 0,2 °C Temperature (electrical thermometry) |
Internal procedure; Calibration and measurement. Indirect method; At permanent location (S) | Internal procedure PT 206 based on EURAMET cg-20 v. 5.0 | |
| 62 | Thermostatic chambers | Calibration — Temperature (electrical thermometry) -100 °C do 100 °C · CMC 0,05 °C 100 °C to 200 °C · CMC 0,1 °C 200 °C to 400 °C · CMC 0,2 °C Temperature (electrical thermometry) |
Internal procedure; Calibration and measurement. Indirect method; Outside of permanent location (P) | Internal procedure PT 206 based on EURAMET cg-20 v. 5.0 | |
| 63 | Steam sterilisation chambers (e.g. autoclaves) | Calibration — Temperature (electrical thermometry) 0 °C to 200 °C · CMC 0,2 °C Temperature (electrical thermometry) |
Internal procedure; Indirect method; At permanent location (S) | Internal procedure PT 206 | |
| 64 | Steam sterilisation chambers (e.g. autoclaves) | Calibration — Temperature (electrical thermometry) 0 °C to 200 °C · CMC 0,2 °C Temperature (electrical thermometry) |
Internal procedure; Indirect method; Outside of permanent location (P) | Internal procedure PT 206 | |
| 65 | Climatic chambers | Calibration — Temperature (electrical thermometry) -100 °C do 100 °C · CMC 0,05 °C 100 °C to 200 °C · CMC 0,1 °C 200 °C to 400 °C · CMC 0,2 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) | Internal procedure PT 206 based on EURAMET cg-20 v. 5.0 | |
| 66 | Climatic chambers | Calibration — Temperature (electrical thermometry) -100 °C do 100 °C · CMC 0,05 °C 100 °C to 200 °C · CMC 0,1 °C 200 °C to 400 °C · CMC 0,2 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure PT 206 based on EURAMET cg-20 v. 5.0 | |
| 67 | Temperature calibrators | Calibration — Temperature (electrical thermometry) -100 °C do 150 °C · CMC 0,02 °C 150 °C do 420 °C · CMC 0,03 °C 420 °C do 650 °C · CMC 0,07 °C 650 °C do 1085 °C · CMC 0,7 °C 1085 °C to 1200 °C · CMC 1,2 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) | Internal procedure PT 206 based on EURAMET cg-13 v. 4.0 | |
| 68 | Temperature calibrators | Calibration — Temperature (electrical thermometry) -100 °C do 420 °C · CMC 0,1 °C 420 °C do 650 °C · CMC 0,2 °C 650 °C do 1085 °C · CMC 0,7 °C 1085 °C to 1200 °C · CMC 1,2 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure PT 206 based on EURAMET cg-13 v. 4.0 | |
| 69 | Furnaces | Calibration — Temperature (electrical thermometry) 0 °C do 420 °C · CMC 0,03 °C 420 °C do 650 °C · CMC 0,07 °C 650 °C do 1085 °C · CMC 0,7 °C 1085 °C to 1200 °C · CMC 1,2 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) | Internal procedure PT 206 | |
| 70 | Furnaces | Calibration — Temperature (electrical thermometry) 0 °C do 650 °C · CMC 0,2 °C 650 °C do 1085 °C · CMC 0,7 °C 1085 °C to 1200 °C · CMC 1,2 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure PT 206 | |
| 71 | Dial thermometers (pressure-spring and bimetallic) | Calibration — Temperature (non-electrical thermometry) 0 °C to 120 °C · CMC 0,1 °C Temperature (non-electrical thermometry) |
Internal procedure; Indirect method; At permanent location (S) | Internal procedure PT 204 | |
| 72 | Dial thermometers (pressure-spring and bimetallic) | Calibration — Temperature (non-electrical thermometry) 0 °C to 120 °C · CMC 0,2 °C Temperature (non-electrical thermometry) |
Internal procedure; Indirect method; Outside of permanent location (P) | Internal procedure PT 204 | |
| 73 | Pyrometers (including radiation, photoelectric and multiband pyrometers, non-contact temperature measuring systems) | Calibration — Temperature (radiation thermometry) 30 °C to 350 °C · CMC 2,9 °C Temperature (radiation thermometry) |
Internal procedure; At permanent location (S) | Internal procedure PT 205 | |
| 74 | Thermal imaging cameras Line scanners |
Calibration — Temperature (radiation thermometry) 30 °C to 350 °C · CMC 2,9 °C Temperature (radiation thermometry) |
Internal procedure; Calibration of the temperature measurement error only; At permanent location (S) | Internal procedure PT 205 | |
Reference standards (20)
EURAMET cg-13 v. 4.0
EURAMET cg-15 v. 3.0
EURAMET cg-17 v. 4.0
EURAMET cg-20 v. 5.0
EURAMET cg-8 v. 3.1
PT 201
PT 202
PT 203
PT 204
PT 205
PT 206
PT 301
PT 302
PT 401
PT 402
PT 403
PT 404
PT 501
PT 502
PT 503