{"lab":{"_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","imported_at":"2026-11-15T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Gen. Juliana Filipowicza 7, 52-208 Wrocław","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"20.12.2024","city":"Wrocław","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.","cycle_from":"16.01.2026","cycle_to":"18.01.2030","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"7.01","pl":"napięcie DC","en":"DC voltage","de":"Gleichspannung","zh":"直流电压","cs":"stejnosměrné napětí (DC)"},{"codes":"7.02","pl":"prąd DC","en":"DC current","de":"DC-Strom","zh":"直流电流","cs":"proud DC"},{"codes":"7.03","pl":"napięcie AC","en":"AC voltage","de":"AC-Spannung","zh":"交流电压","cs":"napětí AC"},{"codes":"7.04","pl":"prąd AC","en":"AC current","de":"AC-Strom","zh":"交流电流","cs":"proud AC"},{"codes":"7.05","pl":"rezystancja DC","en":"DC resistance","de":"DC-Widerstand","zh":"直流电阻","cs":"odpor DC"},{"codes":"7.15","pl":"elektryczna symulacja wielkości","en":"electrical simulation of quantities","de":"elektrische Simulation von Größen","zh":"量值的电模拟","cs":"elektrická simulace veličin"},{"codes":"14.02","pl":"wilgotność względna","en":"relative humidity","de":"relative Feuchte","zh":"相对湿度","cs":"relativní vlhkost"},{"codes":"17.01","pl":"ciśnienie","en":"pressure","de":"Druck","zh":"压力","cs":"tlak"},{"codes":"19.01","pl":"temperatura (termometria elektryczna)","en":"temperature (electrical thermometry)","de":"Temperatur (elektrische Thermometrie)","zh":"温度（电测温）","cs":"teplota (elektrická termometrie)"},{"codes":"19.02","pl":"temperatura (termometria nieelektryczna)","en":"temperature (non-electrical thermometry)","de":"Temperatur (nichtelektrische Thermometrie)","zh":"温度（非电测温）","cs":"teplota (neelektrická termometrie)"},{"codes":"19.03","pl":"temperatura (termometria radiacyjna)","en":"temperature (radiation thermometry)","de":"Temperatur (Strahlungsthermometrie)","zh":"温度（辐射测温）","cs":"teplota (radiační termometrie)"}],"has_en":true,"has_zh":true,"issue":{"no":"25","date":"16.01.2026"},"issue_date":"16.01.2026","issue_number":"25","lab_division":"Laboratorium Pomiarowe","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[17.0140357,51.0569414]},"map_coord":[51.0569414,17.0140357],"map_geo":"nominatim-street","methods_count":74,"name":"ERG95 Spółka z ograniczoną odpowiedzialnością","parse_date":"2026-11-15T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-15T12:00:00.000Z","pdf_files":["AP_092.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: napięcie DC, prąd DC, napięcie AC, prąd AC, rezystancja DC, elektryczna symulacja wielkości, wilgotność względna, ciśnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna), temperatura (termometria radiacyjna). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"erg95 spółka z ograniczoną odpowiedzialnością laboratorium pomiarowe ul. gen. juliana filipowicza 7, 52-208 wrocław laboratorium wzorcujące. wielkości mierzone: napięcie dc, prąd dc, napięcie ac, prąd ac, rezystancja dc, elektryczna symulacja wielkości, wilgotność względna, ciśnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna), temperatura (termometria radiacyjna). w stałej lokalizacji (s) i/lub poza nią (p). ap 092 ap092 laboratorium wzorcujące wzorcowanie kalibracja dc voltage dc current ac voltage ac current dc resistance electrical simulation of quantities relative humidity pressure temperature (electrical thermometry) temperature (non-electrical thermometry) temperature (radiation thermometry) erg95 spolka z ograniczona odpowiedzialnoscia laboratorium pomiarowe ul. gen. juliana filipowicza 7, 52-208 wroclaw laboratorium wzorcujace. wielkosci mierzone: napiecie dc, prad dc, napiecie ac, prad ac, rezystancja dc, elektryczna symulacja wielkosci, wilgotnosc wzgledna, cisnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna), temperatura (termometria radiacyjna). w stalej lokalizacji (s) i/lub poza nia (p). ap 092 ap092 laboratorium wzorcujace wzorcowanie kalibracja dc voltage dc current ac voltage ac current dc resistance electrical simulation of quantities relative humidity pressure temperature (electrical thermometry) temperature (non-electrical thermometry) temperature (radiation thermometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20092,podmiot.html","source_pdf_sha256":"a52e7426e12d838449f82737e3ff53866d2925c0a3f6266fa86b7b253f52a295","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/15/8099796e245564756b97a91dee2510f6/AP%20092.pdf","status":"active","updated_at":"2026-11-15T12:00:00.000Z","valid_from":"19-01-2006","valid_until":"18-01-2030","website":"www.erg95.pl","lab_division_en":"Measurement Laboratory","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"lab_division_de":"Messlabor","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","lab_division_zh":"测量实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"lab_division_cs":"Měřicí laboratoř","pelny_cs":true},"methods":[{"_id":"7de25e8cebf2323c47592f86","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Przetworniki","test_object_en":"Transmitters","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0,01 mV do 100 mV","cmc":"2 µV"},{"name":"","range":"0,1 V do 1 V","cmc":"5,0·10⁻⁶ · U + 9 µV"},{"name":"","range":"1 V do 10 V","cmc":"5,0·10⁻⁶ · U + 0,09 mV"},{"name":"","range":"10 V do 100 V","cmc":"4,0·10⁻⁶ · U + 0,9 mV"}],"parameters_en":[{"name":"","range":"0,01 mV to 100 mV","cmc":"2 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"5,0·10⁻⁶ · U + 9 µV"},{"name":"","range":"1 V to 10 V","cmc":"5,0·10⁻⁶ · U + 0,09 mV"},{"name":"","range":"10 V to 100 V","cmc":"4,0·10⁻⁶ · U + 0,9 mV"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0,01 mV do 100 mV CMC 2 µV\n0,1 V do 1 V CMC 5,0·10⁻⁶ · U + 9 µV\n1 V do 10 V CMC 5,0·10⁻⁶ · U + 0,09 mV\n10 V do 100 V CMC 4,0·10⁻⁶ · U + 0,9 mV\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 401","norm_bases":["PT 401"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":"U – wartość mierzona (V)","note_en":"U – measured value (V)","search_text":"Przetworniki Wzorcowanie — Napięcie DC\nZakres:\n0,01 mV do 100 mV CMC 2 µV\n0,1 V do 1 V CMC 5,0·10⁻⁶ · U + 9 µV\n1 V do 10 V CMC 5,0·10⁻⁶ · U + 0,09 mV\n10 V do 100 V CMC 4,0·10⁻⁶ · U + 0,9 mV\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 401 Przetworniki Wzorcowanie — Napiecie DC\nZakres:\n0,01 mV do 100 mV CMC 2 µV\n0,1 V do 1 V CMC 5,0·10⁻⁶ · U + 9 µV\n1 V do 10 V CMC 5,0·10⁻⁶ · U + 0,09 mV\n10 V do 100 V CMC 4,0·10⁻⁶ · U + 0,9 mV\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 401","search_en":"Transmitters Calibration — DC voltage Internal procedure; Direct method; At permanent location (S) DC voltage Internal procedure Direct method At permanent location (S) Internal procedure PT 401","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 401","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0,01 mV to 100 mV","cmc":"2 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"5,0·10⁻⁶ · U + 9 µV"},{"name":"","range":"1 V to 10 V","cmc":"5,0·10⁻⁶ · U + 0,09 mV"},{"name":"","range":"10 V to 100 V","cmc":"4,0·10⁻⁶ · U + 0,9 mV"}],"reference_de":"Internes Verfahren PT 401","regulatory_area_de":"DC-Spannung","search_de":"Messumformer Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PT 401","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Messumformer","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0,01 mV to 100 mV","cmc":"2 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"5,0·10⁻⁶ · U + 9 µV"},{"name":"","range":"1 V to 10 V","cmc":"5,0·10⁻⁶ · U + 0,09 mV"},{"name":"","range":"10 V to 100 V","cmc":"4,0·10⁻⁶ · U + 0,9 mV"}],"reference_zh":"内部程序 PT 401","regulatory_area_zh":"直流电压","search_zh":"变送器 校准 — 直流电压 内部程序；直接法；在固定地点 (S) 直流电压 内部程序 直接法 在固定地点 (S) 内部程序 PT 401","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"变送器","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0,01 mV to 100 mV","cmc":"2 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"5,0·10⁻⁶ · U + 9 µV"},{"name":"","range":"1 V to 10 V","cmc":"5,0·10⁻⁶ · U + 0,09 mV"},{"name":"","range":"10 V to 100 V","cmc":"4,0·10⁻⁶ · U + 0,9 mV"}],"reference_cs":"Vnitřní postup PT 401","regulatory_area_cs":"Napětí DC","search_cs":"Snímače Kalibrace — Napětí DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Napětí DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 401","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Snímače"},{"_id":"ac005ca29e14dfb0d6f136fe","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Przetworniki","test_object_en":"Transmitters","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0,01 mV do 100 mV","cmc":"2 µV"},{"name":"","range":"0,1 V do 1 V","cmc":"14 µV"},{"name":"","range":"1 V do 10 V","cmc":"0,14 mV"},{"name":"","range":"10 V do 100 V","cmc":"1,4 mV"}],"parameters_en":[{"name":"","range":"0,01 mV to 100 mV","cmc":"2 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"14 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,14 mV"},{"name":"","range":"10 V to 100 V","cmc":"1,4 mV"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0,01 mV do 100 mV CMC 2 µV\n0,1 V do 1 V CMC 14 µV\n1 V do 10 V CMC 0,14 mV\n10 V do 100 V CMC 1,4 mV\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 401","norm_bases":["PT 401"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"P","note":"U – wartość mierzona (V)","note_en":"U – measured value (V)","search_text":"Przetworniki Wzorcowanie — Napięcie DC\nZakres:\n0,01 mV do 100 mV CMC 2 µV\n0,1 V do 1 V CMC 14 µV\n1 V do 10 V CMC 0,14 mV\n10 V do 100 V CMC 1,4 mV\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 401 Przetworniki Wzorcowanie — Napiecie DC\nZakres:\n0,01 mV do 100 mV CMC 2 µV\n0,1 V do 1 V CMC 14 µV\n1 V do 10 V CMC 0,14 mV\n10 V do 100 V CMC 1,4 mV\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 401","search_en":"Transmitters Calibration — DC voltage Internal procedure; Direct method; Outside of permanent location (P) DC voltage Internal procedure Direct method Outside of permanent location (P) Internal procedure PT 401","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 401","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0,01 mV to 100 mV","cmc":"2 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"14 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,14 mV"},{"name":"","range":"10 V to 100 V","cmc":"1,4 mV"}],"reference_de":"Internes Verfahren PT 401","regulatory_area_de":"DC-Spannung","search_de":"Messumformer Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) DC-Spannung Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 401","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Messumformer","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0,01 mV to 100 mV","cmc":"2 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"14 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,14 mV"},{"name":"","range":"10 V to 100 V","cmc":"1,4 mV"}],"reference_zh":"内部程序 PT 401","regulatory_area_zh":"直流电压","search_zh":"变送器 校准 — 直流电压 内部程序；直接法；固定地点以外 (P) 直流电压 内部程序 直接法 固定地点以外 (P) 内部程序 PT 401","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"变送器","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0,01 mV to 100 mV","cmc":"2 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"14 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,14 mV"},{"name":"","range":"10 V to 100 V","cmc":"1,4 mV"}],"reference_cs":"Vnitřní postup PT 401","regulatory_area_cs":"Napětí DC","search_cs":"Snímače Kalibrace — Napětí DC Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Napětí DC Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 401","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Snímače"},{"_id":"69a6ee87d6f7879cfdc9fd0f","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Multimetry\nMierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMierniki parametrów sieci\nMierniki cęgowe\nKarty pomiarowe\nPróbniki przebicia\nObciążenia elektroniczne","test_object_en":"Multimeters\nAnalogue voltmeters\nDigital voltmeters\nPower network parameter meters\nClamp meters\nData acquisition cards\nBreakdown testers\nElectronic loads","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0,0001 mV do 10 mV","cmc":"0,9 µV"},{"name":"","range":"10 mV do 100 mV","cmc":"1,0·10⁻⁵ · U + 0,9 µV"},{"name":"","range":"0,1 V do 1 V","cmc":"9,0·10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V do 10 V","cmc":"9,0·10⁻⁶ · U + 7 µV"},{"name":"","range":"10 V do 100 V","cmc":"7,0·10⁻⁶ · U + 0,095 mV"},{"name":"","range":"100 V do 1050 V","cmc":"5,0·10⁻⁶ · U + 1 mV"}],"parameters_en":[{"name":"","range":"0,0001 mV to 10 mV","cmc":"0,9 µV"},{"name":"","range":"10 mV to 100 mV","cmc":"1,0·10⁻⁵ · U + 0,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"9,0·10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"9,0·10⁻⁶ · U + 7 µV"},{"name":"","range":"10 V to 100 V","cmc":"7,0·10⁻⁶ · U + 0,095 mV"},{"name":"","range":"100 V to 1050 V","cmc":"5,0·10⁻⁶ · U + 1 mV"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0,0001 mV do 10 mV CMC 0,9 µV\n10 mV do 100 mV CMC 1,0·10⁻⁵ · U + 0,9 µV\n0,1 V do 1 V CMC 9,0·10⁻⁶ · U + 2 µV\n1 V do 10 V CMC 9,0·10⁻⁶ · U + 7 µV\n10 V do 100 V CMC 7,0·10⁻⁶ · U + 0,095 mV\n100 V do 1050 V CMC 5,0·10⁻⁶ · U + 1 mV\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":"U – wartość mierzona (V)","note_en":"U – measured value (V)","search_text":"Multimetry\nMierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMierniki parametrów sieci\nMierniki cęgowe\nKarty pomiarowe\nPróbniki przebicia\nObciążenia elektroniczne Wzorcowanie — Napięcie DC\nZakres:\n0,0001 mV do 10 mV CMC 0,9 µV\n10 mV do 100 mV CMC 1,0·10⁻⁵ · U + 0,9 µV\n0,1 V do 1 V CMC 9,0·10⁻⁶ · U + 2 µV\n1 V do 10 V CMC 9,0·10⁻⁶ · U + 7 µV\n10 V do 100 V CMC 7,0·10⁻⁶ · U + 0,095 mV\n100 V do 1050 V CMC 5,0·10⁻⁶ · U + 1 mV\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0 Multimetry\nMierniki napiecia analogowe\nMierniki napiecia cyfrowe\nMierniki parametrow sieci\nMierniki cegowe\nKarty pomiarowe\nProbniki przebicia\nObciazenia elektroniczne Wzorcowanie — Napiecie DC\nZakres:\n0,0001 mV do 10 mV CMC 0,9 µV\n10 mV do 100 mV CMC 1,0·10⁻⁵ · U + 0,9 µV\n0,1 V do 1 V CMC 9,0·10⁻⁶ · U + 2 µV\n1 V do 10 V CMC 9,0·10⁻⁶ · U + 7 µV\n10 V do 100 V CMC 7,0·10⁻⁶ · U + 0,095 mV\n100 V do 1050 V CMC 5,0·10⁻⁶ · U + 1 mV\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Multimeters Analogue voltmeters Digital voltmeters Power network parameter meters Clamp meters Data acquisition cards Breakdown testers Electronic loads Calibration — DC voltage Internal procedure; At permanent location (S) DC voltage Internal procedure At permanent location (S) Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0,0001 mV to 10 mV","cmc":"0,9 µV"},{"name":"","range":"10 mV to 100 mV","cmc":"1,0·10⁻⁵ · U + 0,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"9,0·10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"9,0·10⁻⁶ · U + 7 µV"},{"name":"","range":"10 V to 100 V","cmc":"7,0·10⁻⁶ · U + 0,095 mV"},{"name":"","range":"100 V to 1050 V","cmc":"5,0·10⁻⁶ · U + 1 mV"}],"reference_de":"Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"DC-Spannung","search_de":"Multimeter Analoge Spannungsmessgeräte Digitale Spannungsmessgeräte Netzparametermessgeräte Zangenmessgeräte Messkarten Durchschlagprüfgeräte Elektronische Lasten Kalibrierung — DC-Spannung Internes Verfahren; Am festen Standort (S) DC-Spannung Internes Verfahren Am festen Standort (S) Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter\nAnaloge Spannungsmessgeräte\nDigitale Spannungsmessgeräte\nNetzparametermessgeräte\nZangenmessgeräte\nMesskarten\nDurchschlagprüfgeräte\nElektronische Lasten","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0,0001 mV to 10 mV","cmc":"0,9 µV"},{"name":"","range":"10 mV to 100 mV","cmc":"1,0·10⁻⁵ · U + 0,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"9,0·10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"9,0·10⁻⁶ · U + 7 µV"},{"name":"","range":"10 V to 100 V","cmc":"7,0·10⁻⁶ · U + 0,095 mV"},{"name":"","range":"100 V to 1050 V","cmc":"5,0·10⁻⁶ · U + 1 mV"}],"reference_zh":"内部程序 PT 402 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"直流电压","search_zh":"万用表 模拟电压表 数字电压表 电网参数测量仪 钳形表 测量卡 击穿测试仪 电子负载 校准 — 直流电压 内部程序；在固定地点 (S) 直流电压 内部程序 在固定地点 (S) 内部程序 PT 402 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"万用表\n模拟电压表\n数字电压表\n电网参数测量仪\n钳形表\n测量卡\n击穿测试仪\n电子负载","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0,0001 mV to 10 mV","cmc":"0,9 µV"},{"name":"","range":"10 mV to 100 mV","cmc":"1,0·10⁻⁵ · U + 0,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"9,0·10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"9,0·10⁻⁶ · U + 7 µV"},{"name":"","range":"10 V to 100 V","cmc":"7,0·10⁻⁶ · U + 0,095 mV"},{"name":"","range":"100 V to 1050 V","cmc":"5,0·10⁻⁶ · U + 1 mV"}],"reference_cs":"Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Napětí DC","search_cs":"Multimetry Analogové měřiče napětí Digitální měřiče napětí Měřiče parametrů sítě Klešťové měřiče Měřicí karty Zkoušečky průrazu Elektronické zátěže Kalibrace — Napětí DC Vnitřní postup; Ve stálé lokalitě (S) Napětí DC Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry\nAnalogové měřiče napětí\nDigitální měřiče napětí\nMěřiče parametrů sítě\nKlešťové měřiče\nMěřicí karty\nZkoušečky průrazu\nElektronické zátěže"},{"_id":"c5ceb8ea1d2b8cf95ed381ba","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Multimetry\nMierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMierniki parametrów sieci\nMierniki cęgowe\nKarty pomiarowe\nPróbniki przebicia\nObciążenia elektroniczne","test_object_en":"Multimeters\nAnalogue voltmeters\nDigital voltmeters\nPower network parameter meters\nClamp meters\nData acquisition cards\nBreakdown testers\nElectronic loads","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0,001 mV do 100 mV","cmc":"1,9 µV"},{"name":"","range":"0,1 V do 1 V","cmc":"11 µV"},{"name":"","range":"1 V do 10 V","cmc":"0,11 mV"},{"name":"","range":"10 V do 100 V","cmc":"0,92 mV"},{"name":"","range":"100 V do 1050 V","cmc":"12 mV"}],"parameters_en":[{"name":"","range":"0,001 mV to 100 mV","cmc":"1,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"11 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,11 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,92 mV"},{"name":"","range":"100 V to 1050 V","cmc":"12 mV"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0,001 mV do 100 mV CMC 1,9 µV\n0,1 V do 1 V CMC 11 µV\n1 V do 10 V CMC 0,11 mV\n10 V do 100 V CMC 0,92 mV\n100 V do 1050 V CMC 12 mV\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"P","note":"U – wartość mierzona (V)","note_en":"U – measured value (V)","search_text":"Multimetry\nMierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMierniki parametrów sieci\nMierniki cęgowe\nKarty pomiarowe\nPróbniki przebicia\nObciążenia elektroniczne Wzorcowanie — Napięcie DC\nZakres:\n0,001 mV do 100 mV CMC 1,9 µV\n0,1 V do 1 V CMC 11 µV\n1 V do 10 V CMC 0,11 mV\n10 V do 100 V CMC 0,92 mV\n100 V do 1050 V CMC 12 mV\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0 Multimetry\nMierniki napiecia analogowe\nMierniki napiecia cyfrowe\nMierniki parametrow sieci\nMierniki cegowe\nKarty pomiarowe\nProbniki przebicia\nObciazenia elektroniczne Wzorcowanie — Napiecie DC\nZakres:\n0,001 mV do 100 mV CMC 1,9 µV\n0,1 V do 1 V CMC 11 µV\n1 V do 10 V CMC 0,11 mV\n10 V do 100 V CMC 0,92 mV\n100 V do 1050 V CMC 12 mV\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Multimeters Analogue voltmeters Digital voltmeters Power network parameter meters Clamp meters Data acquisition cards Breakdown testers Electronic loads Calibration — DC voltage Internal procedure; Outside of permanent location (P) DC voltage Internal procedure Outside of permanent location (P) Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0,001 mV to 100 mV","cmc":"1,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"11 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,11 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,92 mV"},{"name":"","range":"100 V to 1050 V","cmc":"12 mV"}],"reference_de":"Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"DC-Spannung","search_de":"Multimeter Analoge Spannungsmessgeräte Digitale Spannungsmessgeräte Netzparametermessgeräte Zangenmessgeräte Messkarten Durchschlagprüfgeräte Elektronische Lasten Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) DC-Spannung Internes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Multimeter\nAnaloge Spannungsmessgeräte\nDigitale Spannungsmessgeräte\nNetzparametermessgeräte\nZangenmessgeräte\nMesskarten\nDurchschlagprüfgeräte\nElektronische Lasten","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0,001 mV to 100 mV","cmc":"1,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"11 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,11 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,92 mV"},{"name":"","range":"100 V to 1050 V","cmc":"12 mV"}],"reference_zh":"内部程序 PT 402 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"直流电压","search_zh":"万用表 模拟电压表 数字电压表 电网参数测量仪 钳形表 测量卡 击穿测试仪 电子负载 校准 — 直流电压 内部程序；固定地点以外 (P) 直流电压 内部程序 固定地点以外 (P) 内部程序 PT 402 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"万用表\n模拟电压表\n数字电压表\n电网参数测量仪\n钳形表\n测量卡\n击穿测试仪\n电子负载","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0,001 mV to 100 mV","cmc":"1,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"11 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,11 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,92 mV"},{"name":"","range":"100 V to 1050 V","cmc":"12 mV"}],"reference_cs":"Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Napětí DC","search_cs":"Multimetry Analogové měřiče napětí Digitální měřiče napětí Měřiče parametrů sítě Klešťové měřiče Měřicí karty Zkoušečky průrazu Elektronické zátěže Kalibrace — Napětí DC Vnitřní postup; Mimo stálé pracoviště (P) Napětí DC Vnitřní postup Mimo stálou lokalitu (P) Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Multimetry\nAnalogové měřiče napětí\nDigitální měřiče napětí\nMěřiče parametrů sítě\nKlešťové měřiče\nMěřicí karty\nZkoušečky průrazu\nElektronické zátěže"},{"_id":"777fa09ea24b1904be651801","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kalibratory\nZasilacze","test_object_en":"Calibrators\nPower supplies","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0,0001 mV do 10 mV","cmc":"0,9 µV"},{"name":"","range":"10 mV do 100 mV","cmc":"1,0·10⁻⁵ · U + 0,9 µV"},{"name":"","range":"0,1 V do 1 V","cmc":"9,0·10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V do 10 V","cmc":"9,0·10⁻⁶ · U + 7 µV"},{"name":"","range":"10 V do 100 V","cmc":"7,0·10⁻⁶ · U + 0,095 mV"},{"name":"","range":"100 V do 1050 V","cmc":"5,0·10⁻⁶ · U + 1 mV"}],"parameters_en":[{"name":"","range":"0,0001 mV to 10 mV","cmc":"0,9 µV"},{"name":"","range":"10 mV to 100 mV","cmc":"1,0·10⁻⁵ · U + 0,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"9,0·10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"9,0·10⁻⁶ · U + 7 µV"},{"name":"","range":"10 V to 100 V","cmc":"7,0·10⁻⁶ · U + 0,095 mV"},{"name":"","range":"100 V to 1050 V","cmc":"5,0·10⁻⁶ · U + 1 mV"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0,0001 mV do 10 mV CMC 0,9 µV\n10 mV do 100 mV CMC 1,0·10⁻⁵ · U + 0,9 µV\n0,1 V do 1 V CMC 9,0·10⁻⁶ · U + 2 µV\n1 V do 10 V CMC 9,0·10⁻⁶ · U + 7 µV\n10 V do 100 V CMC 7,0·10⁻⁶ · U + 0,095 mV\n100 V do 1050 V CMC 5,0·10⁻⁶ · U + 1 mV\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 403","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":"U – wartość mierzona (V)","note_en":"U – measured value (V)","search_text":"Kalibratory\nZasilacze Wzorcowanie — Napięcie DC\nZakres:\n0,0001 mV do 10 mV CMC 0,9 µV\n10 mV do 100 mV CMC 1,0·10⁻⁵ · U + 0,9 µV\n0,1 V do 1 V CMC 9,0·10⁻⁶ · U + 2 µV\n1 V do 10 V CMC 9,0·10⁻⁶ · U + 7 µV\n10 V do 100 V CMC 7,0·10⁻⁶ · U + 0,095 mV\n100 V do 1050 V CMC 5,0·10⁻⁶ · U + 1 mV\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0 Kalibratory\nZasilacze Wzorcowanie — Napiecie DC\nZakres:\n0,0001 mV do 10 mV CMC 0,9 µV\n10 mV do 100 mV CMC 1,0·10⁻⁵ · U + 0,9 µV\n0,1 V do 1 V CMC 9,0·10⁻⁶ · U + 2 µV\n1 V do 10 V CMC 9,0·10⁻⁶ · U + 7 µV\n10 V do 100 V CMC 7,0·10⁻⁶ · U + 0,095 mV\n100 V do 1050 V CMC 5,0·10⁻⁶ · U + 1 mV\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Calibrators Power supplies Calibration — DC voltage Internal procedure; At permanent location (S) DC voltage Internal procedure At permanent location (S) Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0,0001 mV to 10 mV","cmc":"0,9 µV"},{"name":"","range":"10 mV to 100 mV","cmc":"1,0·10⁻⁵ · U + 0,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"9,0·10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"9,0·10⁻⁶ · U + 7 µV"},{"name":"","range":"10 V to 100 V","cmc":"7,0·10⁻⁶ · U + 0,095 mV"},{"name":"","range":"100 V to 1050 V","cmc":"5,0·10⁻⁶ · U + 1 mV"}],"reference_de":"Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"DC-Spannung","search_de":"Kalibratoren Netzgeräte Kalibrierung — DC-Spannung Internes Verfahren; Am festen Standort (S) DC-Spannung Internes Verfahren Am festen Standort (S) Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0,0001 mV to 10 mV","cmc":"0,9 µV"},{"name":"","range":"10 mV to 100 mV","cmc":"1,0·10⁻⁵ · U + 0,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"9,0·10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"9,0·10⁻⁶ · U + 7 µV"},{"name":"","range":"10 V to 100 V","cmc":"7,0·10⁻⁶ · U + 0,095 mV"},{"name":"","range":"100 V to 1050 V","cmc":"5,0·10⁻⁶ · U + 1 mV"}],"reference_zh":"内部程序 PT 403 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"直流电压","search_zh":"校准器 电源 校准 — 直流电压 内部程序；在固定地点 (S) 直流电压 内部程序 在固定地点 (S) 内部程序 PT 403 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器\n电源","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0,0001 mV to 10 mV","cmc":"0,9 µV"},{"name":"","range":"10 mV to 100 mV","cmc":"1,0·10⁻⁵ · U + 0,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"9,0·10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"9,0·10⁻⁶ · U + 7 µV"},{"name":"","range":"10 V to 100 V","cmc":"7,0·10⁻⁶ · U + 0,095 mV"},{"name":"","range":"100 V to 1050 V","cmc":"5,0·10⁻⁶ · U + 1 mV"}],"reference_cs":"Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Napětí DC","search_cs":"Kalibrátory Napájecí zdroje Kalibrace — Napětí DC Vnitřní postup; Ve stálé lokalitě (S) Napětí DC Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nNapájecí zdroje"},{"_id":"25af744896b1c9eb9f018e39","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kalibratory\nZasilacze","test_object_en":"Calibrators\nPower supplies","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0,001 mV do 100 mV","cmc":"1,9 µV"},{"name":"","range":"0,1 V do 1 V","cmc":"11 µV"},{"name":"","range":"1 V do 10 V","cmc":"0,11 mV"},{"name":"","range":"10 V do 100 V","cmc":"0,92 mV"},{"name":"","range":"100 V do 1050 V","cmc":"12 mV"}],"parameters_en":[{"name":"","range":"0,001 mV to 100 mV","cmc":"1,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"11 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,11 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,92 mV"},{"name":"","range":"100 V to 1050 V","cmc":"12 mV"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0,001 mV do 100 mV CMC 1,9 µV\n0,1 V do 1 V CMC 11 µV\n1 V do 10 V CMC 0,11 mV\n10 V do 100 V CMC 0,92 mV\n100 V do 1050 V CMC 12 mV\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 403","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"P","note":"U – wartość mierzona (V)","note_en":"U – measured value (V)","search_text":"Kalibratory\nZasilacze Wzorcowanie — Napięcie DC\nZakres:\n0,001 mV do 100 mV CMC 1,9 µV\n0,1 V do 1 V CMC 11 µV\n1 V do 10 V CMC 0,11 mV\n10 V do 100 V CMC 0,92 mV\n100 V do 1050 V CMC 12 mV\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0 Kalibratory\nZasilacze Wzorcowanie — Napiecie DC\nZakres:\n0,001 mV do 100 mV CMC 1,9 µV\n0,1 V do 1 V CMC 11 µV\n1 V do 10 V CMC 0,11 mV\n10 V do 100 V CMC 0,92 mV\n100 V do 1050 V CMC 12 mV\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Calibrators Power supplies Calibration — DC voltage Internal procedure; Outside of permanent location (P) DC voltage Internal procedure Outside of permanent location (P) Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0,001 mV to 100 mV","cmc":"1,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"11 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,11 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,92 mV"},{"name":"","range":"100 V to 1050 V","cmc":"12 mV"}],"reference_de":"Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"DC-Spannung","search_de":"Kalibratoren Netzgeräte Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) DC-Spannung Internes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Kalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0,001 mV to 100 mV","cmc":"1,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"11 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,11 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,92 mV"},{"name":"","range":"100 V to 1050 V","cmc":"12 mV"}],"reference_zh":"内部程序 PT 403 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"直流电压","search_zh":"校准器 电源 校准 — 直流电压 内部程序；固定地点以外 (P) 直流电压 内部程序 固定地点以外 (P) 内部程序 PT 403 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"校准器\n电源","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0,001 mV to 100 mV","cmc":"1,9 µV"},{"name":"","range":"0,1 V to 1 V","cmc":"11 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,11 mV"},{"name":"","range":"10 V to 100 V","cmc":"0,92 mV"},{"name":"","range":"100 V to 1050 V","cmc":"12 mV"}],"reference_cs":"Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Napětí DC","search_cs":"Kalibrátory Napájecí zdroje Kalibrace — Napětí DC Vnitřní postup; Mimo stálé pracoviště (P) Napětí DC Vnitřní postup Mimo stálou lokalitu (P) Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Kalibrátory\nNapájecí zdroje"},{"_id":"b8f36a0d6fabcc74c69a661e","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Przetworniki","test_object_en":"Transmitters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,1 µA do 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA do 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA do 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA do 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A do 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A do 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A do 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"}],"parameters_en":[{"name":"","range":"0,1 µA to 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A to 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A to 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,1 µA do 100 µA CMC 1,2·10⁻⁴ · I + 4 nA\n0,1 mA do 1 mA CMC 6,0·10⁻⁵ · I + 11 nA\n1 mA do 10 mA CMC 6,0·10⁻⁵ · I + 0,15 µA\n10 mA do 100 mA CMC 6,0·10⁻⁵ · I + 1,2 µA\n0,1 A do 1 A CMC 1,6·10⁻⁴ · I + 1 µA\n1 A do 3 A CMC 1,0·10⁻⁴ · I + 0,07 mA\n3 A do 10 A CMC 5,0·10⁻⁴ · I + 0,04 mA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 401","norm_bases":["PT 401"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Przetworniki Wzorcowanie — Prąd DC\nZakres:\n0,1 µA do 100 µA CMC 1,2·10⁻⁴ · I + 4 nA\n0,1 mA do 1 mA CMC 6,0·10⁻⁵ · I + 11 nA\n1 mA do 10 mA CMC 6,0·10⁻⁵ · I + 0,15 µA\n10 mA do 100 mA CMC 6,0·10⁻⁵ · I + 1,2 µA\n0,1 A do 1 A CMC 1,6·10⁻⁴ · I + 1 µA\n1 A do 3 A CMC 1,0·10⁻⁴ · I + 0,07 mA\n3 A do 10 A CMC 5,0·10⁻⁴ · I + 0,04 mA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 401 Przetworniki Wzorcowanie — Prad DC\nZakres:\n0,1 µA do 100 µA CMC 1,2·10⁻⁴ · I + 4 nA\n0,1 mA do 1 mA CMC 6,0·10⁻⁵ · I + 11 nA\n1 mA do 10 mA CMC 6,0·10⁻⁵ · I + 0,15 µA\n10 mA do 100 mA CMC 6,0·10⁻⁵ · I + 1,2 µA\n0,1 A do 1 A CMC 1,6·10⁻⁴ · I + 1 µA\n1 A do 3 A CMC 1,0·10⁻⁴ · I + 0,07 mA\n3 A do 10 A CMC 5,0·10⁻⁴ · I + 0,04 mA\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 401","search_en":"Transmitters Calibration — DC current Internal procedure; Direct method; At permanent location (S) DC current Internal procedure Direct method At permanent location (S) Internal procedure PT 401","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 401","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,1 µA to 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA bis 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A to 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A to 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"}],"reference_de":"Internes Verfahren PT 401","regulatory_area_de":"DC-Strom","search_de":"Messumformer Kalibrierung — DC-Strom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PT 401","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Messumformer","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,1 µA to 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A to 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A to 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"}],"reference_zh":"内部程序 PT 401","regulatory_area_zh":"直流电流","search_zh":"变送器 校准 — 直流电流 内部程序；直接法；在固定地点 (S) 直流电流 内部程序 直接法 在固定地点 (S) 内部程序 PT 401","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"变送器","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,1 µA to 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A to 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A to 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"}],"reference_cs":"Vnitřní postup PT 401","regulatory_area_cs":"Proud DC","search_cs":"Snímače Kalibrace — Proud DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 401","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Snímače"},{"_id":"f3d5ae1339f0ec39c421dc96","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Przetworniki","test_object_en":"Transmitters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,001 mA do 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA do 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A do 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A do 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"}],"parameters_en":[{"name":"","range":"0,001 mA to 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A to 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,001 mA do 20 mA CMC 3,5·10⁻⁴ · I + 1,2 µA\n20 mA do 200 mA CMC 3,5·10⁻⁴ · I + 12 µA\n0,2 A do 2 A CMC 3,5·10⁻⁴ · I + 0,2 mA\n2 A do 10 A CMC 3,5·10⁻⁴ · I + 1,2 mA\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 401","norm_bases":["PT 401"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":true,"location_of_activity":"P","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Przetworniki Wzorcowanie — Prąd DC\nZakres:\n0,001 mA do 20 mA CMC 3,5·10⁻⁴ · I + 1,2 µA\n20 mA do 200 mA CMC 3,5·10⁻⁴ · I + 12 µA\n0,2 A do 2 A CMC 3,5·10⁻⁴ · I + 0,2 mA\n2 A do 10 A CMC 3,5·10⁻⁴ · I + 1,2 mA\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 401 Przetworniki Wzorcowanie — Prad DC\nZakres:\n0,001 mA do 20 mA CMC 3,5·10⁻⁴ · I + 1,2 µA\n20 mA do 200 mA CMC 3,5·10⁻⁴ · I + 12 µA\n0,2 A do 2 A CMC 3,5·10⁻⁴ · I + 0,2 mA\n2 A do 10 A CMC 3,5·10⁻⁴ · I + 1,2 mA\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 401","search_en":"Transmitters Calibration — DC current Internal procedure; Direct method; Outside of permanent location (P) DC current Internal procedure Direct method Outside of permanent location (P) Internal procedure PT 401","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 401","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,001 mA to 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A to 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"}],"reference_de":"Internes Verfahren PT 401","regulatory_area_de":"DC-Strom","search_de":"Messumformer Kalibrierung — DC-Strom Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) DC-Strom Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 401","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Messumformer","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,001 mA to 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A to 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"}],"reference_zh":"内部程序 PT 401","regulatory_area_zh":"直流电流","search_zh":"变送器 校准 — 直流电流 内部程序；直接法；固定地点以外 (P) 直流电流 内部程序 直接法 固定地点以外 (P) 内部程序 PT 401","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"变送器","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,001 mA to 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A to 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"}],"reference_cs":"Vnitřní postup PT 401","regulatory_area_cs":"Proud DC","search_cs":"Snímače Kalibrace — Proud DC Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Proud DC Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 401","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Snímače"},{"_id":"a181a37577eb19204e62a5e8","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Multimetry\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMierniki parametrów sieci\nKarty pomiarowe\nObciążenia elektroniczne","test_object_en":"Multimeters\nAnalogue ammeters\nDigital ammeters\nPower network parameter meters\nData acquisition cards\nElectronic loads","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,1 µA do 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA do 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA do 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA do 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A do 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A do 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A do 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"}],"parameters_en":[{"name":"","range":"0,1 µA to 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A to 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A to 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,1 µA do 100 µA CMC 1,2·10⁻⁴ · I + 4 nA\n0,1 mA do 1 mA CMC 6,0·10⁻⁵ · I + 11 nA\n1 mA do 10 mA CMC 6,0·10⁻⁵ · I + 0,15 µA\n10 mA do 100 mA CMC 6,0·10⁻⁵ · I + 1,2 µA\n0,1 A do 1 A CMC 1,6·10⁻⁴ · I + 1 µA\n1 A do 3 A CMC 1,0·10⁻⁴ · I + 0,07 mA\n3 A do 10 A CMC 5,0·10⁻⁴ · I + 0,04 mA\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Multimetry\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMierniki parametrów sieci\nKarty pomiarowe\nObciążenia elektroniczne Wzorcowanie — Prąd DC\nZakres:\n0,1 µA do 100 µA CMC 1,2·10⁻⁴ · I + 4 nA\n0,1 mA do 1 mA CMC 6,0·10⁻⁵ · I + 11 nA\n1 mA do 10 mA CMC 6,0·10⁻⁵ · I + 0,15 µA\n10 mA do 100 mA CMC 6,0·10⁻⁵ · I + 1,2 µA\n0,1 A do 1 A CMC 1,6·10⁻⁴ · I + 1 µA\n1 A do 3 A CMC 1,0·10⁻⁴ · I + 0,07 mA\n3 A do 10 A CMC 5,0·10⁻⁴ · I + 0,04 mA\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0 Multimetry\nMierniki pradu analogowe\nMierniki pradu cyfrowe\nMierniki parametrow sieci\nKarty pomiarowe\nObciazenia elektroniczne Wzorcowanie — Prad DC\nZakres:\n0,1 µA do 100 µA CMC 1,2·10⁻⁴ · I + 4 nA\n0,1 mA do 1 mA CMC 6,0·10⁻⁵ · I + 11 nA\n1 mA do 10 mA CMC 6,0·10⁻⁵ · I + 0,15 µA\n10 mA do 100 mA CMC 6,0·10⁻⁵ · I + 1,2 µA\n0,1 A do 1 A CMC 1,6·10⁻⁴ · I + 1 µA\n1 A do 3 A CMC 1,0·10⁻⁴ · I + 0,07 mA\n3 A do 10 A CMC 5,0·10⁻⁴ · I + 0,04 mA\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Multimeters Analogue ammeters Digital ammeters Power network parameter meters Data acquisition cards Electronic loads Calibration — DC current Internal procedure; At permanent location (S) DC current Internal procedure At permanent location (S) Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,1 µA to 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA bis 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A to 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A to 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"}],"reference_de":"Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"DC-Strom","search_de":"Multimeter Analoge Strommessgeräte Digitale Strommessgeräte Netzparametermessgeräte Messkarten Elektronische Lasten Kalibrierung — DC-Strom Internes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Am festen Standort (S) Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter\nAnaloge Strommessgeräte\nDigitale Strommessgeräte\nNetzparametermessgeräte\nMesskarten\nElektronische Lasten","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,1 µA to 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A to 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A to 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"}],"reference_zh":"内部程序 PT 402 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"直流电流","search_zh":"万用表 模拟电流表 数字电流表 电网参数测量仪 测量卡 电子负载 校准 — 直流电流 内部程序；在固定地点 (S) 直流电流 内部程序 在固定地点 (S) 内部程序 PT 402 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"万用表\n模拟电流表\n数字电流表\n电网参数测量仪\n测量卡\n电子负载","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,1 µA to 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A to 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A to 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"}],"reference_cs":"Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Proud DC","search_cs":"Multimetry Analogové měřiče proudu Digitální měřiče proudu Měřiče parametrů sítě Měřicí karty Elektronické zátěže Kalibrace — Proud DC Vnitřní postup; Ve stálé lokalitě (S) Proud DC Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry\nAnalogové měřiče proudu\nDigitální měřiče proudu\nMěřiče parametrů sítě\nMěřicí karty\nElektronické zátěže"},{"_id":"317b8d9e8a72e30d24d48049","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Multimetry\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMierniki parametrów sieci\nKarty pomiarowe\nObciążenia elektroniczne","test_object_en":"Multimeters\nAnalogue ammeters\nDigital ammeters\nPower network parameter meters\nData acquisition cards\nElectronic loads","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,001 mA do 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA do 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A do 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A do 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"}],"parameters_en":[{"name":"","range":"0,001 mA to 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A to 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,001 mA do 20 mA CMC 3,5·10⁻⁴ · I + 1,2 µA\n20 mA do 200 mA CMC 3,5·10⁻⁴ · I + 12 µA\n0,2 A do 2 A CMC 3,5·10⁻⁴ · I + 0,2 mA\n2 A do 10 A CMC 3,5·10⁻⁴ · I + 1,2 mA\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":true,"location_of_activity":"P","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Multimetry\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMierniki parametrów sieci\nKarty pomiarowe\nObciążenia elektroniczne Wzorcowanie — Prąd DC\nZakres:\n0,001 mA do 20 mA CMC 3,5·10⁻⁴ · I + 1,2 µA\n20 mA do 200 mA CMC 3,5·10⁻⁴ · I + 12 µA\n0,2 A do 2 A CMC 3,5·10⁻⁴ · I + 0,2 mA\n2 A do 10 A CMC 3,5·10⁻⁴ · I + 1,2 mA\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0 Multimetry\nMierniki pradu analogowe\nMierniki pradu cyfrowe\nMierniki parametrow sieci\nKarty pomiarowe\nObciazenia elektroniczne Wzorcowanie — Prad DC\nZakres:\n0,001 mA do 20 mA CMC 3,5·10⁻⁴ · I + 1,2 µA\n20 mA do 200 mA CMC 3,5·10⁻⁴ · I + 12 µA\n0,2 A do 2 A CMC 3,5·10⁻⁴ · I + 0,2 mA\n2 A do 10 A CMC 3,5·10⁻⁴ · I + 1,2 mA\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Multimeters Analogue ammeters Digital ammeters Power network parameter meters Data acquisition cards Electronic loads Calibration — DC current Internal procedure; Outside of permanent location (P) DC current Internal procedure Outside of permanent location (P) Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,001 mA to 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A to 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"}],"reference_de":"Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"DC-Strom","search_de":"Multimeter Analoge Strommessgeräte Digitale Strommessgeräte Netzparametermessgeräte Messkarten Elektronische Lasten Kalibrierung — DC-Strom Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) DC-Strom Internes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Multimeter\nAnaloge Strommessgeräte\nDigitale Strommessgeräte\nNetzparametermessgeräte\nMesskarten\nElektronische Lasten","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,001 mA to 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A to 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"}],"reference_zh":"内部程序 PT 402 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"直流电流","search_zh":"万用表 模拟电流表 数字电流表 电网参数测量仪 测量卡 电子负载 校准 — 直流电流 内部程序；固定地点以外 (P) 直流电流 内部程序 固定地点以外 (P) 内部程序 PT 402 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"万用表\n模拟电流表\n数字电流表\n电网参数测量仪\n测量卡\n电子负载","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,001 mA to 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A to 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"}],"reference_cs":"Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Proud DC","search_cs":"Multimetry Analogové měřiče proudu Digitální měřiče proudu Měřiče parametrů sítě Měřicí karty Elektronické zátěže Kalibrace — Proud DC Vnitřní postup; Mimo stálé pracoviště (P) Proud DC Vnitřní postup Mimo stálou lokalitu (P) Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Multimetry\nAnalogové měřiče proudu\nDigitální měřiče proudu\nMěřiče parametrů sítě\nMěřicí karty\nElektronické zátěže"},{"_id":"b1dc0b4cd37852c52715e41f","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,1 A do 1 A","cmc":"0,14 mA"},{"name":"","range":"1 A do 10 A","cmc":"1,4 mA"},{"name":"","range":"10 A do 100 A","cmc":"2,4·10⁻³ · I + 0,4 A"},{"name":"","range":"100 A do 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"parameters_en":[{"name":"","range":"0,1 A to 1 A","cmc":"0,14 mA"},{"name":"","range":"1 A to 10 A","cmc":"1,4 mA"},{"name":"","range":"10 A to 100 A","cmc":"2,4·10⁻³ · I + 0,4 A"},{"name":"","range":"100 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,1 A do 1 A CMC 0,14 mA\n1 A do 10 A CMC 1,4 mA\n10 A do 100 A CMC 2,4·10⁻³ · I + 0,4 A\n100 A do 1000 A CMC 7,0·10⁻⁴ · I + 1,2 A\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Mierniki cęgowe Wzorcowanie — Prąd DC\nZakres:\n0,1 A do 1 A CMC 0,14 mA\n1 A do 10 A CMC 1,4 mA\n10 A do 100 A CMC 2,4·10⁻³ · I + 0,4 A\n100 A do 1000 A CMC 7,0·10⁻⁴ · I + 1,2 A\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0 Mierniki cegowe Wzorcowanie — Prad DC\nZakres:\n0,1 A do 1 A CMC 0,14 mA\n1 A do 10 A CMC 1,4 mA\n10 A do 100 A CMC 2,4·10⁻³ · I + 0,4 A\n100 A do 1000 A CMC 7,0·10⁻⁴ · I + 1,2 A\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Clamp meters Calibration — DC current Internal procedure; At permanent location (S) DC current Internal procedure At permanent location (S) Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,1 A to 1 A","cmc":"0,14 mA"},{"name":"","range":"1 A to 10 A","cmc":"1,4 mA"},{"name":"","range":"10 A to 100 A","cmc":"2,4·10⁻³ · I + 0,4 A"},{"name":"","range":"100 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"reference_de":"Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"DC-Strom","search_de":"Zangenmessgeräte Kalibrierung — DC-Strom Internes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Am festen Standort (S) Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,1 A to 1 A","cmc":"0,14 mA"},{"name":"","range":"1 A to 10 A","cmc":"1,4 mA"},{"name":"","range":"10 A to 100 A","cmc":"2,4·10⁻³ · I + 0,4 A"},{"name":"","range":"100 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"reference_zh":"内部程序 PT 402 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"直流电流","search_zh":"钳形表 校准 — 直流电流 内部程序；在固定地点 (S) 直流电流 内部程序 在固定地点 (S) 内部程序 PT 402 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,1 A to 1 A","cmc":"0,14 mA"},{"name":"","range":"1 A to 10 A","cmc":"1,4 mA"},{"name":"","range":"10 A to 100 A","cmc":"2,4·10⁻³ · I + 0,4 A"},{"name":"","range":"100 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"reference_cs":"Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Proud DC","search_cs":"Klešťové měřiče Kalibrace — Proud DC Vnitřní postup; Ve stálé lokalitě (S) Proud DC Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Klešťové měřiče"},{"_id":"e88d91bc5f3a5bb690ee21ac","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"2 A do 20 A","cmc":"2 mA"},{"name":"","range":"20 A do 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"parameters_en":[{"name":"","range":"2 A to 20 A","cmc":"2 mA"},{"name":"","range":"20 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n2 A do 20 A CMC 2 mA\n20 A do 1000 A CMC 7,0·10⁻⁴ · I + 1,2 A\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":true,"location_of_activity":"P","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Mierniki cęgowe Wzorcowanie — Prąd DC\nZakres:\n2 A do 20 A CMC 2 mA\n20 A do 1000 A CMC 7,0·10⁻⁴ · I + 1,2 A\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0 Mierniki cegowe Wzorcowanie — Prad DC\nZakres:\n2 A do 20 A CMC 2 mA\n20 A do 1000 A CMC 7,0·10⁻⁴ · I + 1,2 A\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Clamp meters Calibration — DC current Internal procedure; Outside of permanent location (P) DC current Internal procedure Outside of permanent location (P) Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"2 A to 20 A","cmc":"2 mA"},{"name":"","range":"20 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"reference_de":"Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"DC-Strom","search_de":"Zangenmessgeräte Kalibrierung — DC-Strom Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) DC-Strom Internes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"2 A to 20 A","cmc":"2 mA"},{"name":"","range":"20 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"reference_zh":"内部程序 PT 402 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"直流电流","search_zh":"钳形表 校准 — 直流电流 内部程序；固定地点以外 (P) 直流电流 内部程序 固定地点以外 (P) 内部程序 PT 402 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"2 A to 20 A","cmc":"2 mA"},{"name":"","range":"20 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"reference_cs":"Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Proud DC","search_cs":"Klešťové měřiče Kalibrace — Proud DC Vnitřní postup; Mimo stálé pracoviště (P) Proud DC Vnitřní postup Mimo stálou lokalitu (P) Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Klešťové měřiče"},{"_id":"66faa8c801fb98279a9d8864","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kalibratory\nZasilacze","test_object_en":"Calibrators\nPower supplies","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,1 µA do 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA do 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA do 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA do 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A do 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A do 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A do 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"},{"name":"","range":"10 A do 200 A","cmc":"4,0·10⁻⁴ · I + 5 mA"}],"parameters_en":[{"name":"","range":"0,1 µA to 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A to 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A to 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"},{"name":"","range":"10 A to 200 A","cmc":"4,0·10⁻⁴ · I + 5 mA"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,1 µA do 100 µA CMC 1,2·10⁻⁴ · I + 4 nA\n0,1 mA do 1 mA CMC 6,0·10⁻⁵ · I + 11 nA\n1 mA do 10 mA CMC 6,0·10⁻⁵ · I + 0,15 µA\n10 mA do 100 mA CMC 6,0·10⁻⁵ · I + 1,2 µA\n0,1 A do 1 A CMC 1,6·10⁻⁴ · I + 1 µA\n1 A do 3 A CMC 1,0·10⁻⁴ · I + 0,07 mA\n3 A do 10 A CMC 5,0·10⁻⁴ · I + 0,04 mA\n10 A do 200 A CMC 4,0·10⁻⁴ · I + 5 mA\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 403","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Kalibratory\nZasilacze Wzorcowanie — Prąd DC\nZakres:\n0,1 µA do 100 µA CMC 1,2·10⁻⁴ · I + 4 nA\n0,1 mA do 1 mA CMC 6,0·10⁻⁵ · I + 11 nA\n1 mA do 10 mA CMC 6,0·10⁻⁵ · I + 0,15 µA\n10 mA do 100 mA CMC 6,0·10⁻⁵ · I + 1,2 µA\n0,1 A do 1 A CMC 1,6·10⁻⁴ · I + 1 µA\n1 A do 3 A CMC 1,0·10⁻⁴ · I + 0,07 mA\n3 A do 10 A CMC 5,0·10⁻⁴ · I + 0,04 mA\n10 A do 200 A CMC 4,0·10⁻⁴ · I + 5 mA\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0 Kalibratory\nZasilacze Wzorcowanie — Prad DC\nZakres:\n0,1 µA do 100 µA CMC 1,2·10⁻⁴ · I + 4 nA\n0,1 mA do 1 mA CMC 6,0·10⁻⁵ · I + 11 nA\n1 mA do 10 mA CMC 6,0·10⁻⁵ · I + 0,15 µA\n10 mA do 100 mA CMC 6,0·10⁻⁵ · I + 1,2 µA\n0,1 A do 1 A CMC 1,6·10⁻⁴ · I + 1 µA\n1 A do 3 A CMC 1,0·10⁻⁴ · I + 0,07 mA\n3 A do 10 A CMC 5,0·10⁻⁴ · I + 0,04 mA\n10 A do 200 A CMC 4,0·10⁻⁴ · I + 5 mA\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Calibrators Power supplies Calibration — DC current Internal procedure; At permanent location (S) DC current Internal procedure At permanent location (S) Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,1 µA to 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA bis 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A to 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A to 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"},{"name":"","range":"10 A to 200 A","cmc":"4,0·10⁻⁴ · I + 5 mA"}],"reference_de":"Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"DC-Strom","search_de":"Kalibratoren Netzgeräte Kalibrierung — DC-Strom Internes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Am festen Standort (S) Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,1 µA to 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A to 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A to 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"},{"name":"","range":"10 A to 200 A","cmc":"4,0·10⁻⁴ · I + 5 mA"}],"reference_zh":"内部程序 PT 403 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"直流电流","search_zh":"校准器 电源 校准 — 直流电流 内部程序；在固定地点 (S) 直流电流 内部程序 在固定地点 (S) 内部程序 PT 403 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器\n电源","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,1 µA to 100 µA","cmc":"1,2·10⁻⁴ · I + 4 nA"},{"name":"","range":"0,1 mA to 1 mA","cmc":"6,0·10⁻⁵ · I + 11 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"6,0·10⁻⁵ · I + 0,15 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"6,0·10⁻⁵ · I + 1,2 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"1,6·10⁻⁴ · I + 1 µA"},{"name":"","range":"1 A to 3 A","cmc":"1,0·10⁻⁴ · I + 0,07 mA"},{"name":"","range":"3 A to 10 A","cmc":"5,0·10⁻⁴ · I + 0,04 mA"},{"name":"","range":"10 A to 200 A","cmc":"4,0·10⁻⁴ · I + 5 mA"}],"reference_cs":"Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Proud DC","search_cs":"Kalibrátory Napájecí zdroje Kalibrace — Proud DC Vnitřní postup; Ve stálé lokalitě (S) Proud DC Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nNapájecí zdroje"},{"_id":"79b5866a7b09d9f8da97a2e0","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kalibratory\nZasilacze","test_object_en":"Calibrators\nPower supplies","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,001 mA do 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA do 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A do 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A do 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"},{"name":"","range":"10 A do 200 A","cmc":"4,0·10⁻⁴ · I + 5 mA"}],"parameters_en":[{"name":"","range":"0,001 mA to 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A to 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"},{"name":"","range":"10 A to 200 A","cmc":"4,0·10⁻⁴ · I + 5 mA"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,001 mA do 20 mA CMC 3,5·10⁻⁴ · I + 1,2 µA\n20 mA do 200 mA CMC 3,5·10⁻⁴ · I + 12 µA\n0,2 A do 2 A CMC 3,5·10⁻⁴ · I + 0,2 mA\n2 A do 10 A CMC 3,5·10⁻⁴ · I + 1,2 mA\n10 A do 200 A CMC 4,0·10⁻⁴ · I + 5 mA\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 403","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":true,"location_of_activity":"P","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Kalibratory\nZasilacze Wzorcowanie — Prąd DC\nZakres:\n0,001 mA do 20 mA CMC 3,5·10⁻⁴ · I + 1,2 µA\n20 mA do 200 mA CMC 3,5·10⁻⁴ · I + 12 µA\n0,2 A do 2 A CMC 3,5·10⁻⁴ · I + 0,2 mA\n2 A do 10 A CMC 3,5·10⁻⁴ · I + 1,2 mA\n10 A do 200 A CMC 4,0·10⁻⁴ · I + 5 mA\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0 Kalibratory\nZasilacze Wzorcowanie — Prad DC\nZakres:\n0,001 mA do 20 mA CMC 3,5·10⁻⁴ · I + 1,2 µA\n20 mA do 200 mA CMC 3,5·10⁻⁴ · I + 12 µA\n0,2 A do 2 A CMC 3,5·10⁻⁴ · I + 0,2 mA\n2 A do 10 A CMC 3,5·10⁻⁴ · I + 1,2 mA\n10 A do 200 A CMC 4,0·10⁻⁴ · I + 5 mA\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Calibrators Power supplies Calibration — DC current Internal procedure; Outside of permanent location (P) DC current Internal procedure Outside of permanent location (P) Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,001 mA to 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A to 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"},{"name":"","range":"10 A to 200 A","cmc":"4,0·10⁻⁴ · I + 5 mA"}],"reference_de":"Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"DC-Strom","search_de":"Kalibratoren Netzgeräte Kalibrierung — DC-Strom Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) DC-Strom Internes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Kalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,001 mA to 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A to 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"},{"name":"","range":"10 A to 200 A","cmc":"4,0·10⁻⁴ · I + 5 mA"}],"reference_zh":"内部程序 PT 403 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"直流电流","search_zh":"校准器 电源 校准 — 直流电流 内部程序；固定地点以外 (P) 直流电流 内部程序 固定地点以外 (P) 内部程序 PT 403 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"校准器\n电源","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,001 mA to 20 mA","cmc":"3,5·10⁻⁴ · I + 1,2 µA"},{"name":"","range":"20 mA to 200 mA","cmc":"3,5·10⁻⁴ · I + 12 µA"},{"name":"","range":"0,2 A to 2 A","cmc":"3,5·10⁻⁴ · I + 0,2 mA"},{"name":"","range":"2 A to 10 A","cmc":"3,5·10⁻⁴ · I + 1,2 mA"},{"name":"","range":"10 A to 200 A","cmc":"4,0·10⁻⁴ · I + 5 mA"}],"reference_cs":"Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Proud DC","search_cs":"Kalibrátory Napájecí zdroje Kalibrace — Proud DC Vnitřní postup; Mimo stálé pracoviště (P) Proud DC Vnitřní postup Mimo stálou lokalitu (P) Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Kalibrátory\nNapájecí zdroje"},{"_id":"d1f5221e6d4dab70e8e3ba44","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Multimetry\nMierniki cęgowe\nMierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMierniki prądu upływu\nMierniki parametrów sieci\nMierniki napięcia przebicia\nMierniki zabezpieczeń różnicowo-prądowych\nPróbniki przebicia\nKarty pomiarowe","test_object_en":"Multimeters\nClamp meters\nAnalogue voltmeters\nDigital voltmeters\nLeakage current meters\nPower network parameter meters\nBreakdown voltage meters\nResidual current device testers\nBreakdown testers\nData acquisition cards","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"40 Hz do 5000 Hz","range":"0,1 mV do 10 mV","cmc":"9 µV"},{"name":"40 Hz do 5000 Hz","range":"10 mV do 100 mV","cmc":"1,1·10⁻⁴ · U + 8 µV"},{"name":"40 Hz do 5000 Hz","range":"0,1 V do 1 V","cmc":"6,0·10⁻⁵ · U + 0,03 mV"},{"name":"40 Hz do 5000 Hz","range":"1 V do 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"40 Hz do 5000 Hz","range":"10 V do 100 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"40 Hz do 5000 Hz","range":"100 V do 1050 V","cmc":"9,0·10⁻⁵ · U + 9 mV"},{"name":"5 kHz do 20 kHz","range":"0,1 mV do 100 mV","cmc":"3,0·10⁻⁴ · U + 7 µV"},{"name":"5 kHz do 20 kHz","range":"0,1 V do 1 V","cmc":"6,0·10⁻⁵ · U + 0,04 mV"},{"name":"5 kHz do 20 kHz","range":"1 V do 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"5 kHz do 20 kHz","range":"10 V do 110 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"20 kHz do 50 kHz","range":"0,1 mV do 100 mV","cmc":"7,0·10⁻⁴ · U + 8 µV"},{"name":"20 kHz do 50 kHz","range":"0,1 V do 1 V","cmc":"1,0·10⁻⁴ · U + 0,07 mV"},{"name":"20 kHz do 50 kHz","range":"1 V do 10 V","cmc":"0,044 %"}],"parameters_en":[{"name":"40 Hz to 5000 Hz","range":"0,1 mV to 10 mV","cmc":"9 µV"},{"name":"40 Hz to 5000 Hz","range":"10 mV to 100 mV","cmc":"1,1·10⁻⁴ · U + 8 µV"},{"name":"40 Hz to 5000 Hz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,03 mV"},{"name":"40 Hz to 5000 Hz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"40 Hz to 5000 Hz","range":"10 V to 100 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"40 Hz to 5000 Hz","range":"100 V to 1050 V","cmc":"9,0·10⁻⁵ · U + 9 mV"},{"name":"5 kHz to 20 kHz","range":"0,1 mV to 100 mV","cmc":"3,0·10⁻⁴ · U + 7 µV"},{"name":"5 kHz to 20 kHz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,04 mV"},{"name":"5 kHz to 20 kHz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"5 kHz to 20 kHz","range":"10 V to 110 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"20 kHz to 50 kHz","range":"0,1 mV to 100 mV","cmc":"7,0·10⁻⁴ · U + 8 µV"},{"name":"20 kHz to 50 kHz","range":"0,1 V to 1 V","cmc":"1,0·10⁻⁴ · U + 0,07 mV"},{"name":"20 kHz to 50 kHz","range":"1 V to 10 V","cmc":"0,044 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 5000 Hz 0,1 mV do 10 mV CMC 9 µV\n40 Hz do 5000 Hz 10 mV do 100 mV CMC 1,1·10⁻⁴ · U + 8 µV\n40 Hz do 5000 Hz 0,1 V do 1 V CMC 6,0·10⁻⁵ · U + 0,03 mV\n40 Hz do 5000 Hz 1 V do 10 V CMC 1,1·10⁻⁴ · U + 0,07 mV\n40 Hz do 5000 Hz 10 V do 100 V CMC 1,2·10⁻⁴ · U + 0,7 mV\n40 Hz do 5000 Hz 100 V do 1050 V CMC 9,0·10⁻⁵ · U + 9 mV\n5 kHz do 20 kHz 0,1 mV do 100 mV CMC 3,0·10⁻⁴ · U + 7 µV\n5 kHz do 20 kHz 0,1 V do 1 V CMC 6,0·10⁻⁵ · U + 0,04 mV\n5 kHz do 20 kHz 1 V do 10 V CMC 1,1·10⁻⁴ · U + 0,07 mV\n5 kHz do 20 kHz 10 V do 110 V CMC 1,2·10⁻⁴ · U + 0,7 mV\n20 kHz do 50 kHz 0,1 mV do 100 mV CMC 7,0·10⁻⁴ · U + 8 µV\n20 kHz do 50 kHz 0,1 V do 1 V CMC 1,0·10⁻⁴ · U + 0,07 mV\n20 kHz do 50 kHz 1 V do 10 V CMC 0,044 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":"U – wartość mierzona (V)","note_en":"U – measured value (V)","search_text":"Multimetry\nMierniki cęgowe\nMierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMierniki prądu upływu\nMierniki parametrów sieci\nMierniki napięcia przebicia\nMierniki zabezpieczeń różnicowo-prądowych\nPróbniki przebicia\nKarty pomiarowe Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 5000 Hz 0,1 mV do 10 mV CMC 9 µV\n40 Hz do 5000 Hz 10 mV do 100 mV CMC 1,1·10⁻⁴ · U + 8 µV\n40 Hz do 5000 Hz 0,1 V do 1 V CMC 6,0·10⁻⁵ · U + 0,03 mV\n40 Hz do 5000 Hz 1 V do 10 V CMC 1,1·10⁻⁴ · U + 0,07 mV\n40 Hz do 5000 Hz 10 V do 100 V CMC 1,2·10⁻⁴ · U + 0,7 mV\n40 Hz do 5000 Hz 100 V do 1050 V CMC 9,0·10⁻⁵ · U + 9 mV\n5 kHz do 20 kHz 0,1 mV do 100 mV CMC 3,0·10⁻⁴ · U + 7 µV\n5 kHz do 20 kHz 0,1 V do 1 V CMC 6,0·10⁻⁵ · U + 0,04 mV\n5 kHz do 20 kHz 1 V do 10 V CMC 1,1·10⁻⁴ · U + 0,07 mV\n5 kHz do 20 kHz 10 V do 110 V CMC 1,2·10⁻⁴ · U + 0,7 mV\n20 kHz do 50 kHz 0,1 mV do 100 mV CMC 7,0·10⁻⁴ · U + 8 µV\n20 kHz do 50 kHz 0,1 V do 1 V CMC 1,0·10⁻⁴ · U + 0,07 mV\n20 kHz do 50 kHz 1 V do 10 V CMC 0,044 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0 Multimetry\nMierniki cegowe\nMierniki napiecia analogowe\nMierniki napiecia cyfrowe\nMierniki pradu uplywu\nMierniki parametrow sieci\nMierniki napiecia przebicia\nMierniki zabezpieczen roznicowo-pradowych\nProbniki przebicia\nKarty pomiarowe Wzorcowanie — Napiecie AC\nZakres:\n40 Hz do 5000 Hz 0,1 mV do 10 mV CMC 9 µV\n40 Hz do 5000 Hz 10 mV do 100 mV CMC 1,1·10⁻⁴ · U + 8 µV\n40 Hz do 5000 Hz 0,1 V do 1 V CMC 6,0·10⁻⁵ · U + 0,03 mV\n40 Hz do 5000 Hz 1 V do 10 V CMC 1,1·10⁻⁴ · U + 0,07 mV\n40 Hz do 5000 Hz 10 V do 100 V CMC 1,2·10⁻⁴ · U + 0,7 mV\n40 Hz do 5000 Hz 100 V do 1050 V CMC 9,0·10⁻⁵ · U + 9 mV\n5 kHz do 20 kHz 0,1 mV do 100 mV CMC 3,0·10⁻⁴ · U + 7 µV\n5 kHz do 20 kHz 0,1 V do 1 V CMC 6,0·10⁻⁵ · U + 0,04 mV\n5 kHz do 20 kHz 1 V do 10 V CMC 1,1·10⁻⁴ · U + 0,07 mV\n5 kHz do 20 kHz 10 V do 110 V CMC 1,2·10⁻⁴ · U + 0,7 mV\n20 kHz do 50 kHz 0,1 mV do 100 mV CMC 7,0·10⁻⁴ · U + 8 µV\n20 kHz do 50 kHz 0,1 V do 1 V CMC 1,0·10⁻⁴ · U + 0,07 mV\n20 kHz do 50 kHz 1 V do 10 V CMC 0,044 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Multimeters Clamp meters Analogue voltmeters Digital voltmeters Leakage current meters Power network parameter meters Breakdown voltage meters Residual current device testers Breakdown testers Data acquisition cards Calibration — AC voltage Internal procedure; At permanent location (S) AC voltage Internal procedure At permanent location (S) 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 5 kHz to 20 kHz 5 kHz to 20 kHz 5 kHz to 20 kHz 5 kHz to 20 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"40 Hz bis 5000 Hz","range":"0,1 mV to 10 mV","cmc":"9 µV"},{"name":"40 Hz bis 5000 Hz","range":"10 mV to 100 mV","cmc":"1,1·10⁻⁴ · U + 8 µV"},{"name":"40 Hz bis 5000 Hz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,03 mV"},{"name":"40 Hz bis 5000 Hz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"40 Hz bis 5000 Hz","range":"10 V to 100 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"40 Hz bis 5000 Hz","range":"100 V to 1050 V","cmc":"9,0·10⁻⁵ · U + 9 mV"},{"name":"5 kHz bis 20 kHz","range":"0,1 mV to 100 mV","cmc":"3,0·10⁻⁴ · U + 7 µV"},{"name":"5 kHz bis 20 kHz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,04 mV"},{"name":"5 kHz bis 20 kHz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"5 kHz bis 20 kHz","range":"10 V to 110 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"20 kHz bis 50 kHz","range":"0,1 mV to 100 mV","cmc":"7,0·10⁻⁴ · U + 8 µV"},{"name":"20 kHz bis 50 kHz","range":"0,1 V to 1 V","cmc":"1,0·10⁻⁴ · U + 0,07 mV"},{"name":"20 kHz bis 50 kHz","range":"1 V to 10 V","cmc":"0,044 %"}],"reference_de":"Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"AC-Spannung","search_de":"Multimeter Zangenmessgeräte Analoge Spannungsmessgeräte Digitale Spannungsmessgeräte Ableitstrommessgeräte Netzparametermessgeräte Durchschlagspannungsmessgeräte Prüfgeräte für Fehlerstrom-Schutzeinrichtungen Durchschlagprüfgeräte Messkarten Kalibrierung — Wechselspannung Internes Verfahren; Am festen Standort (S) AC-Spannung Internes Verfahren Am festen Standort (S) 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 5 kHz bis 20 kHz 5 kHz bis 20 kHz 5 kHz bis 20 kHz 5 kHz bis 20 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter\nZangenmessgeräte\nAnaloge Spannungsmessgeräte\nDigitale Spannungsmessgeräte\nAbleitstrommessgeräte\nNetzparametermessgeräte\nDurchschlagspannungsmessgeräte\nPrüfgeräte für Fehlerstrom-Schutzeinrichtungen\nDurchschlagprüfgeräte\nMesskarten","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"40 Hz 至 5000 Hz","range":"0,1 mV to 10 mV","cmc":"9 µV"},{"name":"40 Hz 至 5000 Hz","range":"10 mV to 100 mV","cmc":"1,1·10⁻⁴ · U + 8 µV"},{"name":"40 Hz 至 5000 Hz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,03 mV"},{"name":"40 Hz 至 5000 Hz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"40 Hz 至 5000 Hz","range":"10 V to 100 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"40 Hz 至 5000 Hz","range":"100 V to 1050 V","cmc":"9,0·10⁻⁵ · U + 9 mV"},{"name":"5 kHz 至 20 kHz","range":"0,1 mV to 100 mV","cmc":"3,0·10⁻⁴ · U + 7 µV"},{"name":"5 kHz 至 20 kHz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,04 mV"},{"name":"5 kHz 至 20 kHz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"5 kHz 至 20 kHz","range":"10 V to 110 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"20 kHz 至 50 kHz","range":"0,1 mV to 100 mV","cmc":"7,0·10⁻⁴ · U + 8 µV"},{"name":"20 kHz 至 50 kHz","range":"0,1 V to 1 V","cmc":"1,0·10⁻⁴ · U + 0,07 mV"},{"name":"20 kHz 至 50 kHz","range":"1 V to 10 V","cmc":"0,044 %"}],"reference_zh":"内部程序 PT 402 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"交流电压","search_zh":"万用表 钳形表 模拟电压表 数字电压表 泄漏电流表 电网参数测量仪 击穿电压测量仪 剩余电流保护装置测试仪 击穿测试仪 测量卡 校准 — 交流电压 内部程序；在固定地点 (S) 交流电压 内部程序 在固定地点 (S) 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 5 kHz 至 20 kHz 5 kHz 至 20 kHz 5 kHz 至 20 kHz 5 kHz 至 20 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 内部程序 PT 402 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"万用表\n钳形表\n模拟电压表\n数字电压表\n泄漏电流表\n电网参数测量仪\n击穿电压测量仪\n剩余电流保护装置测试仪\n击穿测试仪\n测量卡","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"40 Hz až 5000 Hz","range":"0,1 mV to 10 mV","cmc":"9 µV"},{"name":"40 Hz až 5000 Hz","range":"10 mV to 100 mV","cmc":"1,1·10⁻⁴ · U + 8 µV"},{"name":"40 Hz až 5000 Hz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,03 mV"},{"name":"40 Hz až 5000 Hz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"40 Hz až 5000 Hz","range":"10 V to 100 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"40 Hz až 5000 Hz","range":"100 V to 1050 V","cmc":"9,0·10⁻⁵ · U + 9 mV"},{"name":"5 kHz až 20 kHz","range":"0,1 mV to 100 mV","cmc":"3,0·10⁻⁴ · U + 7 µV"},{"name":"5 kHz až 20 kHz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,04 mV"},{"name":"5 kHz až 20 kHz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"5 kHz až 20 kHz","range":"10 V to 110 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"20 kHz až 50 kHz","range":"0,1 mV to 100 mV","cmc":"7,0·10⁻⁴ · U + 8 µV"},{"name":"20 kHz až 50 kHz","range":"0,1 V to 1 V","cmc":"1,0·10⁻⁴ · U + 0,07 mV"},{"name":"20 kHz až 50 kHz","range":"1 V to 10 V","cmc":"0,044 %"}],"reference_cs":"Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Napětí AC","search_cs":"Multimetry Klešťové měřiče Analogové měřiče napětí Digitální měřiče napětí Měřiče unikajícího proudu Měřiče parametrů sítě Měřiče průrazného napětí Zkoušečky proudových chráničů Zkoušečky průrazu Měřicí karty Kalibrace — Napětí AC Vnitřní postup; Ve stálé lokalitě (S) Napětí AC Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 5 kHz až 20 kHz 5 kHz až 20 kHz 5 kHz až 20 kHz 5 kHz až 20 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry\nKlešťové měřiče\nAnalogové měřiče napětí\nDigitální měřiče napětí\nMěřiče unikajícího proudu\nMěřiče parametrů sítě\nMěřiče průrazného napětí\nZkoušečky proudových chráničů\nZkoušečky průrazu\nMěřicí karty"},{"_id":"884a17f1e32130bec0405085","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Multimetry\nMierniki cęgowe\nMierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMierniki prądu upływu\nMierniki parametrów sieci\nMierniki napięcia przebicia\nMierniki zabezpieczeń różnicowo-prądowych\nPróbniki przebicia\nKarty pomiarowe","test_object_en":"Multimeters\nClamp meters\nAnalogue voltmeters\nDigital voltmeters\nLeakage current meters\nPower network parameter meters\nBreakdown voltage meters\nResidual current device testers\nBreakdown testers\nData acquisition cards","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"40 Hz do 5000 Hz","range":"0,1 mV do 200 mV","cmc":"7,0·10⁻³ · U + 0,05 mV"},{"name":"40 Hz do 5000 Hz","range":"0,2 V do 2 V","cmc":"1,2·10⁻³ · U + 0,5 mV"},{"name":"40 Hz do 5000 Hz","range":"2 V do 20 V","cmc":"1,2·10⁻³ · U + 5 mV"},{"name":"40 Hz do 5000 Hz","range":"20 V do 200 V","cmc":"1,2·10⁻³ · U + 0,05 V"},{"name":"40 Hz do 2000 Hz","range":"200 V do 1050 V","cmc":"1,2·10⁻³ · U + 0,24 V"}],"parameters_en":[{"name":"40 Hz to 5000 Hz","range":"0,1 mV to 200 mV","cmc":"7,0·10⁻³ · U + 0,05 mV"},{"name":"40 Hz to 5000 Hz","range":"0,2 V to 2 V","cmc":"1,2·10⁻³ · U + 0,5 mV"},{"name":"40 Hz to 5000 Hz","range":"2 V to 20 V","cmc":"1,2·10⁻³ · U + 5 mV"},{"name":"40 Hz to 5000 Hz","range":"20 V to 200 V","cmc":"1,2·10⁻³ · U + 0,05 V"},{"name":"40 Hz to 2000 Hz","range":"200 V to 1050 V","cmc":"1,2·10⁻³ · U + 0,24 V"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 5000 Hz 0,1 mV do 200 mV CMC 7,0·10⁻³ · U + 0,05 mV\n40 Hz do 5000 Hz 0,2 V do 2 V CMC 1,2·10⁻³ · U + 0,5 mV\n40 Hz do 5000 Hz 2 V do 20 V CMC 1,2·10⁻³ · U + 5 mV\n40 Hz do 5000 Hz 20 V do 200 V CMC 1,2·10⁻³ · U + 0,05 V\n40 Hz do 2000 Hz 200 V do 1050 V CMC 1,2·10⁻³ · U + 0,24 V\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"P","note":"U – wartość mierzona (V)","note_en":"U – measured value (V)","search_text":"Multimetry\nMierniki cęgowe\nMierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMierniki prądu upływu\nMierniki parametrów sieci\nMierniki napięcia przebicia\nMierniki zabezpieczeń różnicowo-prądowych\nPróbniki przebicia\nKarty pomiarowe Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 5000 Hz 0,1 mV do 200 mV CMC 7,0·10⁻³ · U + 0,05 mV\n40 Hz do 5000 Hz 0,2 V do 2 V CMC 1,2·10⁻³ · U + 0,5 mV\n40 Hz do 5000 Hz 2 V do 20 V CMC 1,2·10⁻³ · U + 5 mV\n40 Hz do 5000 Hz 20 V do 200 V CMC 1,2·10⁻³ · U + 0,05 V\n40 Hz do 2000 Hz 200 V do 1050 V CMC 1,2·10⁻³ · U + 0,24 V\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0 Multimetry\nMierniki cegowe\nMierniki napiecia analogowe\nMierniki napiecia cyfrowe\nMierniki pradu uplywu\nMierniki parametrow sieci\nMierniki napiecia przebicia\nMierniki zabezpieczen roznicowo-pradowych\nProbniki przebicia\nKarty pomiarowe Wzorcowanie — Napiecie AC\nZakres:\n40 Hz do 5000 Hz 0,1 mV do 200 mV CMC 7,0·10⁻³ · U + 0,05 mV\n40 Hz do 5000 Hz 0,2 V do 2 V CMC 1,2·10⁻³ · U + 0,5 mV\n40 Hz do 5000 Hz 2 V do 20 V CMC 1,2·10⁻³ · U + 5 mV\n40 Hz do 5000 Hz 20 V do 200 V CMC 1,2·10⁻³ · U + 0,05 V\n40 Hz do 2000 Hz 200 V do 1050 V CMC 1,2·10⁻³ · U + 0,24 V\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Multimeters Clamp meters Analogue voltmeters Digital voltmeters Leakage current meters Power network parameter meters Breakdown voltage meters Residual current device testers Breakdown testers Data acquisition cards Calibration — AC voltage Internal procedure; Outside of permanent location (P) AC voltage Internal procedure Outside of permanent location (P) 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 2000 Hz Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"40 Hz bis 5000 Hz","range":"0,1 mV to 200 mV","cmc":"7,0·10⁻³ · U + 0,05 mV"},{"name":"40 Hz bis 5000 Hz","range":"0,2 V to 2 V","cmc":"1,2·10⁻³ · U + 0,5 mV"},{"name":"40 Hz bis 5000 Hz","range":"2 V to 20 V","cmc":"1,2·10⁻³ · U + 5 mV"},{"name":"40 Hz bis 5000 Hz","range":"20 V to 200 V","cmc":"1,2·10⁻³ · U + 0,05 V"},{"name":"40 Hz bis 2000 Hz","range":"200 V to 1050 V","cmc":"1,2·10⁻³ · U + 0,24 V"}],"reference_de":"Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"AC-Spannung","search_de":"Multimeter Zangenmessgeräte Analoge Spannungsmessgeräte Digitale Spannungsmessgeräte Ableitstrommessgeräte Netzparametermessgeräte Durchschlagspannungsmessgeräte Prüfgeräte für Fehlerstrom-Schutzeinrichtungen Durchschlagprüfgeräte Messkarten Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) AC-Spannung Internes Verfahren Außerhalb des festen Standorts (P) 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 2000 Hz Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Multimeter\nZangenmessgeräte\nAnaloge Spannungsmessgeräte\nDigitale Spannungsmessgeräte\nAbleitstrommessgeräte\nNetzparametermessgeräte\nDurchschlagspannungsmessgeräte\nPrüfgeräte für Fehlerstrom-Schutzeinrichtungen\nDurchschlagprüfgeräte\nMesskarten","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"40 Hz 至 5000 Hz","range":"0,1 mV to 200 mV","cmc":"7,0·10⁻³ · U + 0,05 mV"},{"name":"40 Hz 至 5000 Hz","range":"0,2 V to 2 V","cmc":"1,2·10⁻³ · U + 0,5 mV"},{"name":"40 Hz 至 5000 Hz","range":"2 V to 20 V","cmc":"1,2·10⁻³ · U + 5 mV"},{"name":"40 Hz 至 5000 Hz","range":"20 V to 200 V","cmc":"1,2·10⁻³ · U + 0,05 V"},{"name":"40 Hz 至 2000 Hz","range":"200 V to 1050 V","cmc":"1,2·10⁻³ · U + 0,24 V"}],"reference_zh":"内部程序 PT 402 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"交流电压","search_zh":"万用表 钳形表 模拟电压表 数字电压表 泄漏电流表 电网参数测量仪 击穿电压测量仪 剩余电流保护装置测试仪 击穿测试仪 测量卡 校准 — 交流电压 内部程序；固定地点以外 (P) 交流电压 内部程序 固定地点以外 (P) 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 2000 Hz 内部程序 PT 402 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"万用表\n钳形表\n模拟电压表\n数字电压表\n泄漏电流表\n电网参数测量仪\n击穿电压测量仪\n剩余电流保护装置测试仪\n击穿测试仪\n测量卡","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"40 Hz až 5000 Hz","range":"0,1 mV to 200 mV","cmc":"7,0·10⁻³ · U + 0,05 mV"},{"name":"40 Hz až 5000 Hz","range":"0,2 V to 2 V","cmc":"1,2·10⁻³ · U + 0,5 mV"},{"name":"40 Hz až 5000 Hz","range":"2 V to 20 V","cmc":"1,2·10⁻³ · U + 5 mV"},{"name":"40 Hz až 5000 Hz","range":"20 V to 200 V","cmc":"1,2·10⁻³ · U + 0,05 V"},{"name":"40 Hz až 2000 Hz","range":"200 V to 1050 V","cmc":"1,2·10⁻³ · U + 0,24 V"}],"reference_cs":"Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Napětí AC","search_cs":"Multimetry Klešťové měřiče Analogové měřiče napětí Digitální měřiče napětí Měřiče unikajícího proudu Měřiče parametrů sítě Měřiče průrazného napětí Zkoušečky proudových chráničů Zkoušečky průrazu Měřicí karty Kalibrace — Napětí AC Vnitřní postup; Mimo stálé pracoviště (P) Napětí AC Vnitřní postup Mimo stálou lokalitu (P) 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 2000 Hz Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Multimetry\nKlešťové měřiče\nAnalogové měřiče napětí\nDigitální měřiče napětí\nMěřiče unikajícího proudu\nMěřiče parametrů sítě\nMěřiče průrazného napětí\nZkoušečky proudových chráničů\nZkoušečky průrazu\nMěřicí karty"},{"_id":"edfcb61e3e4bbdf567a6eacf","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kalibratory\nGeneratory\nZasilacze","test_object_en":"Calibrators\nGenerators\nPower supplies","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"40 Hz do 5000 Hz","range":"0,1 mV do 10 mV","cmc":"9 µV"},{"name":"40 Hz do 5000 Hz","range":"10 mV do 100 mV","cmc":"1,1·10⁻⁴ · U + 8 µV"},{"name":"40 Hz do 5000 Hz","range":"0,1 V do 1 V","cmc":"6,0·10⁻⁵ · U + 0,03 mV"},{"name":"40 Hz do 5000 Hz","range":"1 V do 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"40 Hz do 5000 Hz","range":"10 V do 100 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"40 Hz do 5000 Hz","range":"100 V do 1050 V","cmc":"9,0·10⁻⁵ · U + 9 mV"},{"name":"5 kHz do 20 kHz","range":"0,1 mV do 100 mV","cmc":"3,0·10⁻⁴ · U + 7 µV"},{"name":"5 kHz do 20 kHz","range":"0,1 V do 1 V","cmc":"6,0·10⁻⁵ · U + 0,04 mV"},{"name":"5 kHz do 20 kHz","range":"1 V do 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"5 kHz do 20 kHz","range":"10 V do 110 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"20 kHz do 50 kHz","range":"0,1 mV do 100 mV","cmc":"7,0·10⁻⁴ · U + 8 µV"},{"name":"20 kHz do 50 kHz","range":"0,1 V do 1 V","cmc":"1,0·10⁻⁴ · U + 0,07 mV"},{"name":"20 kHz do 50 kHz","range":"1 V do 10 V","cmc":"0,044 %"}],"parameters_en":[{"name":"40 Hz to 5000 Hz","range":"0,1 mV to 10 mV","cmc":"9 µV"},{"name":"40 Hz to 5000 Hz","range":"10 mV to 100 mV","cmc":"1,1·10⁻⁴ · U + 8 µV"},{"name":"40 Hz to 5000 Hz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,03 mV"},{"name":"40 Hz to 5000 Hz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"40 Hz to 5000 Hz","range":"10 V to 100 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"40 Hz to 5000 Hz","range":"100 V to 1050 V","cmc":"9,0·10⁻⁵ · U + 9 mV"},{"name":"5 kHz to 20 kHz","range":"0,1 mV to 100 mV","cmc":"3,0·10⁻⁴ · U + 7 µV"},{"name":"5 kHz to 20 kHz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,04 mV"},{"name":"5 kHz to 20 kHz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"5 kHz to 20 kHz","range":"10 V to 110 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"20 kHz to 50 kHz","range":"0,1 mV to 100 mV","cmc":"7,0·10⁻⁴ · U + 8 µV"},{"name":"20 kHz to 50 kHz","range":"0,1 V to 1 V","cmc":"1,0·10⁻⁴ · U + 0,07 mV"},{"name":"20 kHz to 50 kHz","range":"1 V to 10 V","cmc":"0,044 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 5000 Hz 0,1 mV do 10 mV CMC 9 µV\n40 Hz do 5000 Hz 10 mV do 100 mV CMC 1,1·10⁻⁴ · U + 8 µV\n40 Hz do 5000 Hz 0,1 V do 1 V CMC 6,0·10⁻⁵ · U + 0,03 mV\n40 Hz do 5000 Hz 1 V do 10 V CMC 1,1·10⁻⁴ · U + 0,07 mV\n40 Hz do 5000 Hz 10 V do 100 V CMC 1,2·10⁻⁴ · U + 0,7 mV\n40 Hz do 5000 Hz 100 V do 1050 V CMC 9,0·10⁻⁵ · U + 9 mV\n5 kHz do 20 kHz 0,1 mV do 100 mV CMC 3,0·10⁻⁴ · U + 7 µV\n5 kHz do 20 kHz 0,1 V do 1 V CMC 6,0·10⁻⁵ · U + 0,04 mV\n5 kHz do 20 kHz 1 V do 10 V CMC 1,1·10⁻⁴ · U + 0,07 mV\n5 kHz do 20 kHz 10 V do 110 V CMC 1,2·10⁻⁴ · U + 0,7 mV\n20 kHz do 50 kHz 0,1 mV do 100 mV CMC 7,0·10⁻⁴ · U + 8 µV\n20 kHz do 50 kHz 0,1 V do 1 V CMC 1,0·10⁻⁴ · U + 0,07 mV\n20 kHz do 50 kHz 1 V do 10 V CMC 0,044 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 403","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":"U – wartość mierzona (V)","note_en":"U – measured value (V)","search_text":"Kalibratory\nGeneratory\nZasilacze Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 5000 Hz 0,1 mV do 10 mV CMC 9 µV\n40 Hz do 5000 Hz 10 mV do 100 mV CMC 1,1·10⁻⁴ · U + 8 µV\n40 Hz do 5000 Hz 0,1 V do 1 V CMC 6,0·10⁻⁵ · U + 0,03 mV\n40 Hz do 5000 Hz 1 V do 10 V CMC 1,1·10⁻⁴ · U + 0,07 mV\n40 Hz do 5000 Hz 10 V do 100 V CMC 1,2·10⁻⁴ · U + 0,7 mV\n40 Hz do 5000 Hz 100 V do 1050 V CMC 9,0·10⁻⁵ · U + 9 mV\n5 kHz do 20 kHz 0,1 mV do 100 mV CMC 3,0·10⁻⁴ · U + 7 µV\n5 kHz do 20 kHz 0,1 V do 1 V CMC 6,0·10⁻⁵ · U + 0,04 mV\n5 kHz do 20 kHz 1 V do 10 V CMC 1,1·10⁻⁴ · U + 0,07 mV\n5 kHz do 20 kHz 10 V do 110 V CMC 1,2·10⁻⁴ · U + 0,7 mV\n20 kHz do 50 kHz 0,1 mV do 100 mV CMC 7,0·10⁻⁴ · U + 8 µV\n20 kHz do 50 kHz 0,1 V do 1 V CMC 1,0·10⁻⁴ · U + 0,07 mV\n20 kHz do 50 kHz 1 V do 10 V CMC 0,044 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0 Kalibratory\nGeneratory\nZasilacze Wzorcowanie — Napiecie AC\nZakres:\n40 Hz do 5000 Hz 0,1 mV do 10 mV CMC 9 µV\n40 Hz do 5000 Hz 10 mV do 100 mV CMC 1,1·10⁻⁴ · U + 8 µV\n40 Hz do 5000 Hz 0,1 V do 1 V CMC 6,0·10⁻⁵ · U + 0,03 mV\n40 Hz do 5000 Hz 1 V do 10 V CMC 1,1·10⁻⁴ · U + 0,07 mV\n40 Hz do 5000 Hz 10 V do 100 V CMC 1,2·10⁻⁴ · U + 0,7 mV\n40 Hz do 5000 Hz 100 V do 1050 V CMC 9,0·10⁻⁵ · U + 9 mV\n5 kHz do 20 kHz 0,1 mV do 100 mV CMC 3,0·10⁻⁴ · U + 7 µV\n5 kHz do 20 kHz 0,1 V do 1 V CMC 6,0·10⁻⁵ · U + 0,04 mV\n5 kHz do 20 kHz 1 V do 10 V CMC 1,1·10⁻⁴ · U + 0,07 mV\n5 kHz do 20 kHz 10 V do 110 V CMC 1,2·10⁻⁴ · U + 0,7 mV\n20 kHz do 50 kHz 0,1 mV do 100 mV CMC 7,0·10⁻⁴ · U + 8 µV\n20 kHz do 50 kHz 0,1 V do 1 V CMC 1,0·10⁻⁴ · U + 0,07 mV\n20 kHz do 50 kHz 1 V do 10 V CMC 0,044 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Calibrators Generators Power supplies Calibration — AC voltage Internal procedure; At permanent location (S) AC voltage Internal procedure At permanent location (S) 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 5 kHz to 20 kHz 5 kHz to 20 kHz 5 kHz to 20 kHz 5 kHz to 20 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"40 Hz bis 5000 Hz","range":"0,1 mV to 10 mV","cmc":"9 µV"},{"name":"40 Hz bis 5000 Hz","range":"10 mV to 100 mV","cmc":"1,1·10⁻⁴ · U + 8 µV"},{"name":"40 Hz bis 5000 Hz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,03 mV"},{"name":"40 Hz bis 5000 Hz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"40 Hz bis 5000 Hz","range":"10 V to 100 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"40 Hz bis 5000 Hz","range":"100 V to 1050 V","cmc":"9,0·10⁻⁵ · U + 9 mV"},{"name":"5 kHz bis 20 kHz","range":"0,1 mV to 100 mV","cmc":"3,0·10⁻⁴ · U + 7 µV"},{"name":"5 kHz bis 20 kHz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,04 mV"},{"name":"5 kHz bis 20 kHz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"5 kHz bis 20 kHz","range":"10 V to 110 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"20 kHz bis 50 kHz","range":"0,1 mV to 100 mV","cmc":"7,0·10⁻⁴ · U + 8 µV"},{"name":"20 kHz bis 50 kHz","range":"0,1 V to 1 V","cmc":"1,0·10⁻⁴ · U + 0,07 mV"},{"name":"20 kHz bis 50 kHz","range":"1 V to 10 V","cmc":"0,044 %"}],"reference_de":"Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"AC-Spannung","search_de":"Kalibratoren Generatoren Netzgeräte Kalibrierung — Wechselspannung Internes Verfahren; Am festen Standort (S) AC-Spannung Internes Verfahren Am festen Standort (S) 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 5 kHz bis 20 kHz 5 kHz bis 20 kHz 5 kHz bis 20 kHz 5 kHz bis 20 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nGeneratoren\nNetzgeräte","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"40 Hz 至 5000 Hz","range":"0,1 mV to 10 mV","cmc":"9 µV"},{"name":"40 Hz 至 5000 Hz","range":"10 mV to 100 mV","cmc":"1,1·10⁻⁴ · U + 8 µV"},{"name":"40 Hz 至 5000 Hz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,03 mV"},{"name":"40 Hz 至 5000 Hz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"40 Hz 至 5000 Hz","range":"10 V to 100 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"40 Hz 至 5000 Hz","range":"100 V to 1050 V","cmc":"9,0·10⁻⁵ · U + 9 mV"},{"name":"5 kHz 至 20 kHz","range":"0,1 mV to 100 mV","cmc":"3,0·10⁻⁴ · U + 7 µV"},{"name":"5 kHz 至 20 kHz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,04 mV"},{"name":"5 kHz 至 20 kHz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"5 kHz 至 20 kHz","range":"10 V to 110 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"20 kHz 至 50 kHz","range":"0,1 mV to 100 mV","cmc":"7,0·10⁻⁴ · U + 8 µV"},{"name":"20 kHz 至 50 kHz","range":"0,1 V to 1 V","cmc":"1,0·10⁻⁴ · U + 0,07 mV"},{"name":"20 kHz 至 50 kHz","range":"1 V to 10 V","cmc":"0,044 %"}],"reference_zh":"内部程序 PT 403 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"交流电压","search_zh":"校准器 发生器 电源 校准 — 交流电压 内部程序；在固定地点 (S) 交流电压 内部程序 在固定地点 (S) 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 5 kHz 至 20 kHz 5 kHz 至 20 kHz 5 kHz 至 20 kHz 5 kHz 至 20 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 内部程序 PT 403 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器\n发生器\n电源","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"40 Hz až 5000 Hz","range":"0,1 mV to 10 mV","cmc":"9 µV"},{"name":"40 Hz až 5000 Hz","range":"10 mV to 100 mV","cmc":"1,1·10⁻⁴ · U + 8 µV"},{"name":"40 Hz až 5000 Hz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,03 mV"},{"name":"40 Hz až 5000 Hz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"40 Hz až 5000 Hz","range":"10 V to 100 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"40 Hz až 5000 Hz","range":"100 V to 1050 V","cmc":"9,0·10⁻⁵ · U + 9 mV"},{"name":"5 kHz až 20 kHz","range":"0,1 mV to 100 mV","cmc":"3,0·10⁻⁴ · U + 7 µV"},{"name":"5 kHz až 20 kHz","range":"0,1 V to 1 V","cmc":"6,0·10⁻⁵ · U + 0,04 mV"},{"name":"5 kHz až 20 kHz","range":"1 V to 10 V","cmc":"1,1·10⁻⁴ · U + 0,07 mV"},{"name":"5 kHz až 20 kHz","range":"10 V to 110 V","cmc":"1,2·10⁻⁴ · U + 0,7 mV"},{"name":"20 kHz až 50 kHz","range":"0,1 mV to 100 mV","cmc":"7,0·10⁻⁴ · U + 8 µV"},{"name":"20 kHz až 50 kHz","range":"0,1 V to 1 V","cmc":"1,0·10⁻⁴ · U + 0,07 mV"},{"name":"20 kHz až 50 kHz","range":"1 V to 10 V","cmc":"0,044 %"}],"reference_cs":"Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Napětí AC","search_cs":"Kalibrátory Generátory Napájecí zdroje Kalibrace — Napětí AC Vnitřní postup; Ve stálé lokalitě (S) Napětí AC Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 5 kHz až 20 kHz 5 kHz až 20 kHz 5 kHz až 20 kHz 5 kHz až 20 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nGenerátory\nNapájecí zdroje"},{"_id":"147d99509a00472a78f70f41","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kalibratory\nGeneratory\nZasilacze","test_object_en":"Calibrators\nGenerators\nPower supplies","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"40 Hz do 5000 Hz","range":"0,1 mV do 200 mV","cmc":"1,2·10⁻³ · U + 0,05 mV"},{"name":"40 Hz do 5000 Hz","range":"0,2 V do 2 V","cmc":"1,2·10⁻³ · U + 0,5 mV"},{"name":"40 Hz do 5000 Hz","range":"2 V do 20 V","cmc":"1,2·10⁻³ · U + 5 mV"},{"name":"40 Hz do 5000 Hz","range":"20 V do 200 V","cmc":"1,2·10⁻³ · U + 0,05 V"},{"name":"40 Hz do 2000 Hz","range":"200 V do 1050 V","cmc":"1,2·10⁻³ · U + 0,24 V"}],"parameters_en":[{"name":"40 Hz to 5000 Hz","range":"0,1 mV to 200 mV","cmc":"1,2·10⁻³ · U + 0,05 mV"},{"name":"40 Hz to 5000 Hz","range":"0,2 V to 2 V","cmc":"1,2·10⁻³ · U + 0,5 mV"},{"name":"40 Hz to 5000 Hz","range":"2 V to 20 V","cmc":"1,2·10⁻³ · U + 5 mV"},{"name":"40 Hz to 5000 Hz","range":"20 V to 200 V","cmc":"1,2·10⁻³ · U + 0,05 V"},{"name":"40 Hz to 2000 Hz","range":"200 V to 1050 V","cmc":"1,2·10⁻³ · U + 0,24 V"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 5000 Hz 0,1 mV do 200 mV CMC 1,2·10⁻³ · U + 0,05 mV\n40 Hz do 5000 Hz 0,2 V do 2 V CMC 1,2·10⁻³ · U + 0,5 mV\n40 Hz do 5000 Hz 2 V do 20 V CMC 1,2·10⁻³ · U + 5 mV\n40 Hz do 5000 Hz 20 V do 200 V CMC 1,2·10⁻³ · U + 0,05 V\n40 Hz do 2000 Hz 200 V do 1050 V CMC 1,2·10⁻³ · U + 0,24 V\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 403","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"P","note":"U – wartość mierzona (V)","note_en":"U – measured value (V)","search_text":"Kalibratory\nGeneratory\nZasilacze Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 5000 Hz 0,1 mV do 200 mV CMC 1,2·10⁻³ · U + 0,05 mV\n40 Hz do 5000 Hz 0,2 V do 2 V CMC 1,2·10⁻³ · U + 0,5 mV\n40 Hz do 5000 Hz 2 V do 20 V CMC 1,2·10⁻³ · U + 5 mV\n40 Hz do 5000 Hz 20 V do 200 V CMC 1,2·10⁻³ · U + 0,05 V\n40 Hz do 2000 Hz 200 V do 1050 V CMC 1,2·10⁻³ · U + 0,24 V\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0 Kalibratory\nGeneratory\nZasilacze Wzorcowanie — Napiecie AC\nZakres:\n40 Hz do 5000 Hz 0,1 mV do 200 mV CMC 1,2·10⁻³ · U + 0,05 mV\n40 Hz do 5000 Hz 0,2 V do 2 V CMC 1,2·10⁻³ · U + 0,5 mV\n40 Hz do 5000 Hz 2 V do 20 V CMC 1,2·10⁻³ · U + 5 mV\n40 Hz do 5000 Hz 20 V do 200 V CMC 1,2·10⁻³ · U + 0,05 V\n40 Hz do 2000 Hz 200 V do 1050 V CMC 1,2·10⁻³ · U + 0,24 V\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Calibrators Generators Power supplies Calibration — AC voltage Internal procedure; Outside of permanent location (P) AC voltage Internal procedure Outside of permanent location (P) 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 2000 Hz Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"40 Hz bis 5000 Hz","range":"0,1 mV to 200 mV","cmc":"1,2·10⁻³ · U + 0,05 mV"},{"name":"40 Hz bis 5000 Hz","range":"0,2 V to 2 V","cmc":"1,2·10⁻³ · U + 0,5 mV"},{"name":"40 Hz bis 5000 Hz","range":"2 V to 20 V","cmc":"1,2·10⁻³ · U + 5 mV"},{"name":"40 Hz bis 5000 Hz","range":"20 V to 200 V","cmc":"1,2·10⁻³ · U + 0,05 V"},{"name":"40 Hz bis 2000 Hz","range":"200 V to 1050 V","cmc":"1,2·10⁻³ · U + 0,24 V"}],"reference_de":"Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"AC-Spannung","search_de":"Kalibratoren Generatoren Netzgeräte Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) AC-Spannung Internes Verfahren Außerhalb des festen Standorts (P) 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 2000 Hz Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Kalibratoren\nGeneratoren\nNetzgeräte","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"40 Hz 至 5000 Hz","range":"0,1 mV to 200 mV","cmc":"1,2·10⁻³ · U + 0,05 mV"},{"name":"40 Hz 至 5000 Hz","range":"0,2 V to 2 V","cmc":"1,2·10⁻³ · U + 0,5 mV"},{"name":"40 Hz 至 5000 Hz","range":"2 V to 20 V","cmc":"1,2·10⁻³ · U + 5 mV"},{"name":"40 Hz 至 5000 Hz","range":"20 V to 200 V","cmc":"1,2·10⁻³ · U + 0,05 V"},{"name":"40 Hz 至 2000 Hz","range":"200 V to 1050 V","cmc":"1,2·10⁻³ · U + 0,24 V"}],"reference_zh":"内部程序 PT 403 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"交流电压","search_zh":"校准器 发生器 电源 校准 — 交流电压 内部程序；固定地点以外 (P) 交流电压 内部程序 固定地点以外 (P) 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 2000 Hz 内部程序 PT 403 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"校准器\n发生器\n电源","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"40 Hz až 5000 Hz","range":"0,1 mV to 200 mV","cmc":"1,2·10⁻³ · U + 0,05 mV"},{"name":"40 Hz až 5000 Hz","range":"0,2 V to 2 V","cmc":"1,2·10⁻³ · U + 0,5 mV"},{"name":"40 Hz až 5000 Hz","range":"2 V to 20 V","cmc":"1,2·10⁻³ · U + 5 mV"},{"name":"40 Hz až 5000 Hz","range":"20 V to 200 V","cmc":"1,2·10⁻³ · U + 0,05 V"},{"name":"40 Hz až 2000 Hz","range":"200 V to 1050 V","cmc":"1,2·10⁻³ · U + 0,24 V"}],"reference_cs":"Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Napětí AC","search_cs":"Kalibrátory Generátory Napájecí zdroje Kalibrace — Napětí AC Vnitřní postup; Mimo stálé pracoviště (P) Napětí AC Vnitřní postup Mimo stálou lokalitu (P) 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 2000 Hz Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Kalibrátory\nGenerátory\nNapájecí zdroje"},{"_id":"59d85c1ce6d320679b43d964","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Multimetry\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMierniki prądu upływu\nSymulatory prądu upływu\nMierniki parametrów sieci\nMierniki zabezpieczeń różnicowoprądowych\nKarty pomiarowe","test_object_en":"Multimeters\nAnalogue ammeters\nDigital ammeters\nLeakage current meters\nLeakage current simulators\nPower network parameter meters\nResidual current device testers\nData acquisition cards","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"40 Hz do 5000 Hz","range":"10 µA do 100 µA","cmc":"1,7·10⁻⁴ · I + 19 nA"},{"name":"40 Hz do 5000 Hz","range":"0,1 mA do 1 mA","cmc":"2,7·10⁻⁴ · I + 0,02 µA"},{"name":"40 Hz do 5000 Hz","range":"1 mA do 10 mA","cmc":"2,7·10⁻⁴ · I + 0,14 µA"},{"name":"40 Hz do 5000 Hz","range":"10 mA do 100 mA","cmc":"2,7·10⁻⁴ · I + 1,4 µA"},{"name":"40 Hz do 5000 Hz","range":"0,1 A do 1 A","cmc":"0,075 %"},{"name":"40 Hz do 5000 Hz","range":"1 A do 10 A","cmc":"0,12 %"}],"parameters_en":[{"name":"40 Hz to 5000 Hz","range":"10 µA to 100 µA","cmc":"1,7·10⁻⁴ · I + 19 nA"},{"name":"40 Hz to 5000 Hz","range":"0,1 mA to 1 mA","cmc":"2,7·10⁻⁴ · I + 0,02 µA"},{"name":"40 Hz to 5000 Hz","range":"1 mA to 10 mA","cmc":"2,7·10⁻⁴ · I + 0,14 µA"},{"name":"40 Hz to 5000 Hz","range":"10 mA to 100 mA","cmc":"2,7·10⁻⁴ · I + 1,4 µA"},{"name":"40 Hz to 5000 Hz","range":"0,1 A to 1 A","cmc":"0,075 %"},{"name":"40 Hz to 5000 Hz","range":"1 A to 10 A","cmc":"0,12 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 5000 Hz 10 µA do 100 µA CMC 1,7·10⁻⁴ · I + 19 nA\n40 Hz do 5000 Hz 0,1 mA do 1 mA CMC 2,7·10⁻⁴ · I + 0,02 µA\n40 Hz do 5000 Hz 1 mA do 10 mA CMC 2,7·10⁻⁴ · I + 0,14 µA\n40 Hz do 5000 Hz 10 mA do 100 mA CMC 2,7·10⁻⁴ · I + 1,4 µA\n40 Hz do 5000 Hz 0,1 A do 1 A CMC 0,075 %\n40 Hz do 5000 Hz 1 A do 10 A CMC 0,12 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Multimetry\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMierniki prądu upływu\nSymulatory prądu upływu\nMierniki parametrów sieci\nMierniki zabezpieczeń różnicowoprądowych\nKarty pomiarowe Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 5000 Hz 10 µA do 100 µA CMC 1,7·10⁻⁴ · I + 19 nA\n40 Hz do 5000 Hz 0,1 mA do 1 mA CMC 2,7·10⁻⁴ · I + 0,02 µA\n40 Hz do 5000 Hz 1 mA do 10 mA CMC 2,7·10⁻⁴ · I + 0,14 µA\n40 Hz do 5000 Hz 10 mA do 100 mA CMC 2,7·10⁻⁴ · I + 1,4 µA\n40 Hz do 5000 Hz 0,1 A do 1 A CMC 0,075 %\n40 Hz do 5000 Hz 1 A do 10 A CMC 0,12 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0 Multimetry\nMierniki pradu analogowe\nMierniki pradu cyfrowe\nMierniki pradu uplywu\nSymulatory pradu uplywu\nMierniki parametrow sieci\nMierniki zabezpieczen roznicowopradowych\nKarty pomiarowe Wzorcowanie — Prad AC\nZakres:\n40 Hz do 5000 Hz 10 µA do 100 µA CMC 1,7·10⁻⁴ · I + 19 nA\n40 Hz do 5000 Hz 0,1 mA do 1 mA CMC 2,7·10⁻⁴ · I + 0,02 µA\n40 Hz do 5000 Hz 1 mA do 10 mA CMC 2,7·10⁻⁴ · I + 0,14 µA\n40 Hz do 5000 Hz 10 mA do 100 mA CMC 2,7·10⁻⁴ · I + 1,4 µA\n40 Hz do 5000 Hz 0,1 A do 1 A CMC 0,075 %\n40 Hz do 5000 Hz 1 A do 10 A CMC 0,12 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Multimeters Analogue ammeters Digital ammeters Leakage current meters Leakage current simulators Power network parameter meters Residual current device testers Data acquisition cards Calibration — AC current Internal procedure; At permanent location (S) AC current Internal procedure At permanent location (S) 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"40 Hz bis 5000 Hz","range":"10 µA to 100 µA","cmc":"1,7·10⁻⁴ · I + 19 nA"},{"name":"40 Hz bis 5000 Hz","range":"0,1 mA to 1 mA","cmc":"2,7·10⁻⁴ · I + 0,02 µA"},{"name":"40 Hz bis 5000 Hz","range":"1 mA to 10 mA","cmc":"2,7·10⁻⁴ · I + 0,14 µA"},{"name":"40 Hz bis 5000 Hz","range":"10 mA bis 100 mA","cmc":"2,7·10⁻⁴ · I + 1,4 µA"},{"name":"40 Hz bis 5000 Hz","range":"0,1 A to 1 A","cmc":"0,075 %"},{"name":"40 Hz bis 5000 Hz","range":"1 A to 10 A","cmc":"0,12 %"}],"reference_de":"Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"AC-Strom","search_de":"Multimeter Analoge Strommessgeräte Digitale Strommessgeräte Ableitstrommessgeräte Ableitstromsimulatoren Netzparametermessgeräte Prüfgeräte für Fehlerstrom-Schutzeinrichtungen Messkarten Kalibrierung — Wechselstrom Internes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Am festen Standort (S) 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter\nAnaloge Strommessgeräte\nDigitale Strommessgeräte\nAbleitstrommessgeräte\nAbleitstromsimulatoren\nNetzparametermessgeräte\nPrüfgeräte für Fehlerstrom-Schutzeinrichtungen\nMesskarten","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"40 Hz 至 5000 Hz","range":"10 µA to 100 µA","cmc":"1,7·10⁻⁴ · I + 19 nA"},{"name":"40 Hz 至 5000 Hz","range":"0,1 mA to 1 mA","cmc":"2,7·10⁻⁴ · I + 0,02 µA"},{"name":"40 Hz 至 5000 Hz","range":"1 mA to 10 mA","cmc":"2,7·10⁻⁴ · I + 0,14 µA"},{"name":"40 Hz 至 5000 Hz","range":"10 mA to 100 mA","cmc":"2,7·10⁻⁴ · I + 1,4 µA"},{"name":"40 Hz 至 5000 Hz","range":"0,1 A to 1 A","cmc":"0,075 %"},{"name":"40 Hz 至 5000 Hz","range":"1 A to 10 A","cmc":"0,12 %"}],"reference_zh":"内部程序 PT 402 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"交流电流","search_zh":"万用表 模拟电流表 数字电流表 泄漏电流表 泄漏电流模拟器 电网参数测量仪 剩余电流保护装置测试仪 测量卡 校准 — 交流电流 内部程序；在固定地点 (S) 交流电流 内部程序 在固定地点 (S) 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 内部程序 PT 402 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"万用表\n模拟电流表\n数字电流表\n泄漏电流表\n泄漏电流模拟器\n电网参数测量仪\n剩余电流保护装置测试仪\n测量卡","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"40 Hz až 5000 Hz","range":"10 µA to 100 µA","cmc":"1,7·10⁻⁴ · I + 19 nA"},{"name":"40 Hz až 5000 Hz","range":"0,1 mA to 1 mA","cmc":"2,7·10⁻⁴ · I + 0,02 µA"},{"name":"40 Hz až 5000 Hz","range":"1 mA to 10 mA","cmc":"2,7·10⁻⁴ · I + 0,14 µA"},{"name":"40 Hz až 5000 Hz","range":"10 mA to 100 mA","cmc":"2,7·10⁻⁴ · I + 1,4 µA"},{"name":"40 Hz až 5000 Hz","range":"0,1 A to 1 A","cmc":"0,075 %"},{"name":"40 Hz až 5000 Hz","range":"1 A to 10 A","cmc":"0,12 %"}],"reference_cs":"Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Proud AC","search_cs":"Multimetry Analogové měřiče proudu Digitální měřiče proudu Měřiče unikajícího proudu Simulátory unikajícího proudu Měřiče parametrů sítě Měřiče proudových chráničů Měřicí karty Kalibrace — Proud AC Vnitřní postup; Ve stálé lokalitě (S) Proud AC Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry\nAnalogové měřiče proudu\nDigitální měřiče proudu\nMěřiče unikajícího proudu\nSimulátory unikajícího proudu\nMěřiče parametrů sítě\nMěřiče proudových chráničů\nMěřicí karty"},{"_id":"43baf6be8eb1588398c71e27","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Multimetry\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMierniki prądu upływu\nSymulatory prądu upływu\nMierniki parametrów sieci\nMierniki zabezpieczeń różnicowoprądowych\nKarty pomiarowe","test_object_en":"Multimeters\nAnalogue ammeters\nDigital ammeters\nLeakage current meters\nLeakage current simulators\nPower network parameter meters\nResidual current device testers\nData acquisition cards","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"40 Hz do 5000 Hz","range":"0,1 mA do 20 mA","cmc":"2 µA"},{"name":"40 Hz do 5000 Hz","range":"20 mA do 200 mA","cmc":"0,02 mA"},{"name":"40 Hz do 5000 Hz","range":"0,2 A do 2 A","cmc":"0,15 mA"},{"name":"40 Hz do 5000 Hz","range":"2 A do 10 A","cmc":"1 mA"}],"parameters_en":[{"name":"40 Hz to 5000 Hz","range":"0,1 mA to 20 mA","cmc":"2 µA"},{"name":"40 Hz to 5000 Hz","range":"20 mA to 200 mA","cmc":"0,02 mA"},{"name":"40 Hz to 5000 Hz","range":"0,2 A to 2 A","cmc":"0,15 mA"},{"name":"40 Hz to 5000 Hz","range":"2 A to 10 A","cmc":"1 mA"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 5000 Hz 0,1 mA do 20 mA CMC 2 µA\n40 Hz do 5000 Hz 20 mA do 200 mA CMC 0,02 mA\n40 Hz do 5000 Hz 0,2 A do 2 A CMC 0,15 mA\n40 Hz do 5000 Hz 2 A do 10 A CMC 1 mA\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"P","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Multimetry\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMierniki prądu upływu\nSymulatory prądu upływu\nMierniki parametrów sieci\nMierniki zabezpieczeń różnicowoprądowych\nKarty pomiarowe Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 5000 Hz 0,1 mA do 20 mA CMC 2 µA\n40 Hz do 5000 Hz 20 mA do 200 mA CMC 0,02 mA\n40 Hz do 5000 Hz 0,2 A do 2 A CMC 0,15 mA\n40 Hz do 5000 Hz 2 A do 10 A CMC 1 mA\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0 Multimetry\nMierniki pradu analogowe\nMierniki pradu cyfrowe\nMierniki pradu uplywu\nSymulatory pradu uplywu\nMierniki parametrow sieci\nMierniki zabezpieczen roznicowopradowych\nKarty pomiarowe Wzorcowanie — Prad AC\nZakres:\n40 Hz do 5000 Hz 0,1 mA do 20 mA CMC 2 µA\n40 Hz do 5000 Hz 20 mA do 200 mA CMC 0,02 mA\n40 Hz do 5000 Hz 0,2 A do 2 A CMC 0,15 mA\n40 Hz do 5000 Hz 2 A do 10 A CMC 1 mA\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Multimeters Analogue ammeters Digital ammeters Leakage current meters Leakage current simulators Power network parameter meters Residual current device testers Data acquisition cards Calibration — AC current Internal procedure; Outside of permanent location (P) AC current Internal procedure Outside of permanent location (P) 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":19,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"40 Hz bis 5000 Hz","range":"0,1 mA to 20 mA","cmc":"2 µA"},{"name":"40 Hz bis 5000 Hz","range":"20 mA to 200 mA","cmc":"0,02 mA"},{"name":"40 Hz bis 5000 Hz","range":"0,2 A to 2 A","cmc":"0,15 mA"},{"name":"40 Hz bis 5000 Hz","range":"2 A to 10 A","cmc":"1 mA"}],"reference_de":"Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"AC-Strom","search_de":"Multimeter Analoge Strommessgeräte Digitale Strommessgeräte Ableitstrommessgeräte Ableitstromsimulatoren Netzparametermessgeräte Prüfgeräte für Fehlerstrom-Schutzeinrichtungen Messkarten Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) AC-Strom Internes Verfahren Außerhalb des festen Standorts (P) 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Multimeter\nAnaloge Strommessgeräte\nDigitale Strommessgeräte\nAbleitstrommessgeräte\nAbleitstromsimulatoren\nNetzparametermessgeräte\nPrüfgeräte für Fehlerstrom-Schutzeinrichtungen\nMesskarten","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"40 Hz 至 5000 Hz","range":"0,1 mA to 20 mA","cmc":"2 µA"},{"name":"40 Hz 至 5000 Hz","range":"20 mA to 200 mA","cmc":"0,02 mA"},{"name":"40 Hz 至 5000 Hz","range":"0,2 A to 2 A","cmc":"0,15 mA"},{"name":"40 Hz 至 5000 Hz","range":"2 A to 10 A","cmc":"1 mA"}],"reference_zh":"内部程序 PT 402 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"交流电流","search_zh":"万用表 模拟电流表 数字电流表 泄漏电流表 泄漏电流模拟器 电网参数测量仪 剩余电流保护装置测试仪 测量卡 校准 — 交流电流 内部程序；固定地点以外 (P) 交流电流 内部程序 固定地点以外 (P) 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 内部程序 PT 402 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"万用表\n模拟电流表\n数字电流表\n泄漏电流表\n泄漏电流模拟器\n电网参数测量仪\n剩余电流保护装置测试仪\n测量卡","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"40 Hz až 5000 Hz","range":"0,1 mA to 20 mA","cmc":"2 µA"},{"name":"40 Hz až 5000 Hz","range":"20 mA to 200 mA","cmc":"0,02 mA"},{"name":"40 Hz až 5000 Hz","range":"0,2 A to 2 A","cmc":"0,15 mA"},{"name":"40 Hz až 5000 Hz","range":"2 A to 10 A","cmc":"1 mA"}],"reference_cs":"Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Proud AC","search_cs":"Multimetry Analogové měřiče proudu Digitální měřiče proudu Měřiče unikajícího proudu Simulátory unikajícího proudu Měřiče parametrů sítě Měřiče proudových chráničů Měřicí karty Kalibrace — Proud AC Vnitřní postup; Mimo stálé pracoviště (P) Proud AC Vnitřní postup Mimo stálou lokalitu (P) 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Multimetry\nAnalogové měřiče proudu\nDigitální měřiče proudu\nMěřiče unikajícího proudu\nSimulátory unikajícího proudu\nMěřiče parametrů sítě\nMěřiče proudových chráničů\nMěřicí karty"},{"_id":"1063a0eb286b6210a672b162","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"45 Hz do 400 Hz","range":"0,1 A do 1 A","cmc":"0,14 mA"},{"name":"45 Hz do 400 Hz","range":"1 A do 10 A","cmc":"1,4 mA"},{"name":"45 Hz do 400 Hz","range":"10 A do 100 A","cmc":"2,4·10⁻³ · I + 0,4 A"},{"name":"45 Hz do 400 Hz","range":"100 A do 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"parameters_en":[{"name":"45 Hz to 400 Hz","range":"0,1 A to 1 A","cmc":"0,14 mA"},{"name":"45 Hz to 400 Hz","range":"1 A to 10 A","cmc":"1,4 mA"},{"name":"45 Hz to 400 Hz","range":"10 A to 100 A","cmc":"2,4·10⁻³ · I + 0,4 A"},{"name":"45 Hz to 400 Hz","range":"100 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n45 Hz do 400 Hz 0,1 A do 1 A CMC 0,14 mA\n45 Hz do 400 Hz 1 A do 10 A CMC 1,4 mA\n45 Hz do 400 Hz 10 A do 100 A CMC 2,4·10⁻³ · I + 0,4 A\n45 Hz do 400 Hz 100 A do 1000 A CMC 7,0·10⁻⁴ · I + 1,2 A\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Mierniki cęgowe Wzorcowanie — Prąd AC\nZakres:\n45 Hz do 400 Hz 0,1 A do 1 A CMC 0,14 mA\n45 Hz do 400 Hz 1 A do 10 A CMC 1,4 mA\n45 Hz do 400 Hz 10 A do 100 A CMC 2,4·10⁻³ · I + 0,4 A\n45 Hz do 400 Hz 100 A do 1000 A CMC 7,0·10⁻⁴ · I + 1,2 A\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0 Mierniki cegowe Wzorcowanie — Prad AC\nZakres:\n45 Hz do 400 Hz 0,1 A do 1 A CMC 0,14 mA\n45 Hz do 400 Hz 1 A do 10 A CMC 1,4 mA\n45 Hz do 400 Hz 10 A do 100 A CMC 2,4·10⁻³ · I + 0,4 A\n45 Hz do 400 Hz 100 A do 1000 A CMC 7,0·10⁻⁴ · I + 1,2 A\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Clamp meters Calibration — AC current Internal procedure; At permanent location (S) AC current Internal procedure At permanent location (S) 45 Hz to 400 Hz 45 Hz to 400 Hz 45 Hz to 400 Hz 45 Hz to 400 Hz Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":20,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"45 Hz bis 400 Hz","range":"0,1 A to 1 A","cmc":"0,14 mA"},{"name":"45 Hz bis 400 Hz","range":"1 A to 10 A","cmc":"1,4 mA"},{"name":"45 Hz bis 400 Hz","range":"10 A to 100 A","cmc":"2,4·10⁻³ · I + 0,4 A"},{"name":"45 Hz bis 400 Hz","range":"100 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"reference_de":"Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"AC-Strom","search_de":"Zangenmessgeräte Kalibrierung — Wechselstrom Internes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Am festen Standort (S) 45 Hz bis 400 Hz 45 Hz bis 400 Hz 45 Hz bis 400 Hz 45 Hz bis 400 Hz Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"45 Hz 至 400 Hz","range":"0,1 A to 1 A","cmc":"0,14 mA"},{"name":"45 Hz 至 400 Hz","range":"1 A to 10 A","cmc":"1,4 mA"},{"name":"45 Hz 至 400 Hz","range":"10 A to 100 A","cmc":"2,4·10⁻³ · I + 0,4 A"},{"name":"45 Hz 至 400 Hz","range":"100 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"reference_zh":"内部程序 PT 402 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"交流电流","search_zh":"钳形表 校准 — 交流电流 内部程序；在固定地点 (S) 交流电流 内部程序 在固定地点 (S) 45 Hz 至 400 Hz 45 Hz 至 400 Hz 45 Hz 至 400 Hz 45 Hz 至 400 Hz 内部程序 PT 402 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"45 Hz až 400 Hz","range":"0,1 A to 1 A","cmc":"0,14 mA"},{"name":"45 Hz až 400 Hz","range":"1 A to 10 A","cmc":"1,4 mA"},{"name":"45 Hz až 400 Hz","range":"10 A to 100 A","cmc":"2,4·10⁻³ · I + 0,4 A"},{"name":"45 Hz až 400 Hz","range":"100 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"reference_cs":"Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Proud AC","search_cs":"Klešťové měřiče Kalibrace — Proud AC Vnitřní postup; Ve stálé lokalitě (S) Proud AC Vnitřní postup Ve stálé lokalitě (S) 45 Hz až 400 Hz 45 Hz až 400 Hz 45 Hz až 400 Hz 45 Hz až 400 Hz Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Klešťové měřiče"},{"_id":"622e463bae47308720dcad85","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"45 Hz do 400 Hz","range":"2 A do 20 A","cmc":"2 mA"},{"name":"45 Hz do 400 Hz","range":"20 A do 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"parameters_en":[{"name":"45 Hz to 400 Hz","range":"2 A to 20 A","cmc":"2 mA"},{"name":"45 Hz to 400 Hz","range":"20 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n45 Hz do 400 Hz 2 A do 20 A CMC 2 mA\n45 Hz do 400 Hz 20 A do 1000 A CMC 7,0·10⁻⁴ · I + 1,2 A\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"P","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Mierniki cęgowe Wzorcowanie — Prąd AC\nZakres:\n45 Hz do 400 Hz 2 A do 20 A CMC 2 mA\n45 Hz do 400 Hz 20 A do 1000 A CMC 7,0·10⁻⁴ · I + 1,2 A\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0 Mierniki cegowe Wzorcowanie — Prad AC\nZakres:\n45 Hz do 400 Hz 2 A do 20 A CMC 2 mA\n45 Hz do 400 Hz 20 A do 1000 A CMC 7,0·10⁻⁴ · I + 1,2 A\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 402 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Clamp meters Calibration — AC current Internal procedure; Outside of permanent location (P) AC current Internal procedure Outside of permanent location (P) 45 Hz to 400 Hz 45 Hz to 400 Hz Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":21,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"45 Hz bis 400 Hz","range":"2 A to 20 A","cmc":"2 mA"},{"name":"45 Hz bis 400 Hz","range":"20 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"reference_de":"Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"AC-Strom","search_de":"Zangenmessgeräte Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) AC-Strom Internes Verfahren Außerhalb des festen Standorts (P) 45 Hz bis 400 Hz 45 Hz bis 400 Hz Internes Verfahren PT 402 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"45 Hz 至 400 Hz","range":"2 A to 20 A","cmc":"2 mA"},{"name":"45 Hz 至 400 Hz","range":"20 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"reference_zh":"内部程序 PT 402 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"交流电流","search_zh":"钳形表 校准 — 交流电流 内部程序；固定地点以外 (P) 交流电流 内部程序 固定地点以外 (P) 45 Hz 至 400 Hz 45 Hz 至 400 Hz 内部程序 PT 402 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"45 Hz až 400 Hz","range":"2 A to 20 A","cmc":"2 mA"},{"name":"45 Hz až 400 Hz","range":"20 A to 1000 A","cmc":"7,0·10⁻⁴ · I + 1,2 A"}],"reference_cs":"Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Proud AC","search_cs":"Klešťové měřiče Kalibrace — Proud AC Vnitřní postup; Mimo stálé pracoviště (P) Proud AC Vnitřní postup Mimo stálou lokalitu (P) 45 Hz až 400 Hz 45 Hz až 400 Hz Vnitřní postup PT 402 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Klešťové měřiče"},{"_id":"35e345c56c3bcc18b3b4b07e","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kalibratory\nGeneratory\nZasilacze","test_object_en":"Calibrators\nGenerators\nPower supplies","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"40 Hz do 5000 Hz","range":"10 µA do 100 µA","cmc":"1,7·10⁻⁴ · I + 19 nA"},{"name":"40 Hz do 5000 Hz","range":"0,1 mA do 1 mA","cmc":"2,7·10⁻⁴ · I + 0,02 µA"},{"name":"40 Hz do 5000 Hz","range":"1 mA do 10 mA","cmc":"2,7·10⁻⁴ · I + 0,14 µA"},{"name":"40 Hz do 5000 Hz","range":"10 mA do 100 mA","cmc":"2,7·10⁻⁴ · I + 1,4 µA"},{"name":"40 Hz do 5000 Hz","range":"0,1 A do 1 A","cmc":"0,075 %"},{"name":"40 Hz do 5000 Hz","range":"1 A do 10 A","cmc":"0,12 %"}],"parameters_en":[{"name":"40 Hz to 5000 Hz","range":"10 µA to 100 µA","cmc":"1,7·10⁻⁴ · I + 19 nA"},{"name":"40 Hz to 5000 Hz","range":"0,1 mA to 1 mA","cmc":"2,7·10⁻⁴ · I + 0,02 µA"},{"name":"40 Hz to 5000 Hz","range":"1 mA to 10 mA","cmc":"2,7·10⁻⁴ · I + 0,14 µA"},{"name":"40 Hz to 5000 Hz","range":"10 mA to 100 mA","cmc":"2,7·10⁻⁴ · I + 1,4 µA"},{"name":"40 Hz to 5000 Hz","range":"0,1 A to 1 A","cmc":"0,075 %"},{"name":"40 Hz to 5000 Hz","range":"1 A to 10 A","cmc":"0,12 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 5000 Hz 10 µA do 100 µA CMC 1,7·10⁻⁴ · I + 19 nA\n40 Hz do 5000 Hz 0,1 mA do 1 mA CMC 2,7·10⁻⁴ · I + 0,02 µA\n40 Hz do 5000 Hz 1 mA do 10 mA CMC 2,7·10⁻⁴ · I + 0,14 µA\n40 Hz do 5000 Hz 10 mA do 100 mA CMC 2,7·10⁻⁴ · I + 1,4 µA\n40 Hz do 5000 Hz 0,1 A do 1 A CMC 0,075 %\n40 Hz do 5000 Hz 1 A do 10 A CMC 0,12 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 403","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Kalibratory\nGeneratory\nZasilacze Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 5000 Hz 10 µA do 100 µA CMC 1,7·10⁻⁴ · I + 19 nA\n40 Hz do 5000 Hz 0,1 mA do 1 mA CMC 2,7·10⁻⁴ · I + 0,02 µA\n40 Hz do 5000 Hz 1 mA do 10 mA CMC 2,7·10⁻⁴ · I + 0,14 µA\n40 Hz do 5000 Hz 10 mA do 100 mA CMC 2,7·10⁻⁴ · I + 1,4 µA\n40 Hz do 5000 Hz 0,1 A do 1 A CMC 0,075 %\n40 Hz do 5000 Hz 1 A do 10 A CMC 0,12 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0 Kalibratory\nGeneratory\nZasilacze Wzorcowanie — Prad AC\nZakres:\n40 Hz do 5000 Hz 10 µA do 100 µA CMC 1,7·10⁻⁴ · I + 19 nA\n40 Hz do 5000 Hz 0,1 mA do 1 mA CMC 2,7·10⁻⁴ · I + 0,02 µA\n40 Hz do 5000 Hz 1 mA do 10 mA CMC 2,7·10⁻⁴ · I + 0,14 µA\n40 Hz do 5000 Hz 10 mA do 100 mA CMC 2,7·10⁻⁴ · I + 1,4 µA\n40 Hz do 5000 Hz 0,1 A do 1 A CMC 0,075 %\n40 Hz do 5000 Hz 1 A do 10 A CMC 0,12 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Calibrators Generators Power supplies Calibration — AC current Internal procedure; At permanent location (S) AC current Internal procedure At permanent location (S) 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":22,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"40 Hz bis 5000 Hz","range":"10 µA to 100 µA","cmc":"1,7·10⁻⁴ · I + 19 nA"},{"name":"40 Hz bis 5000 Hz","range":"0,1 mA to 1 mA","cmc":"2,7·10⁻⁴ · I + 0,02 µA"},{"name":"40 Hz bis 5000 Hz","range":"1 mA to 10 mA","cmc":"2,7·10⁻⁴ · I + 0,14 µA"},{"name":"40 Hz bis 5000 Hz","range":"10 mA bis 100 mA","cmc":"2,7·10⁻⁴ · I + 1,4 µA"},{"name":"40 Hz bis 5000 Hz","range":"0,1 A to 1 A","cmc":"0,075 %"},{"name":"40 Hz bis 5000 Hz","range":"1 A to 10 A","cmc":"0,12 %"}],"reference_de":"Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"AC-Strom","search_de":"Kalibratoren Generatoren Netzgeräte Kalibrierung — Wechselstrom Internes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Am festen Standort (S) 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nGeneratoren\nNetzgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"40 Hz 至 5000 Hz","range":"10 µA to 100 µA","cmc":"1,7·10⁻⁴ · I + 19 nA"},{"name":"40 Hz 至 5000 Hz","range":"0,1 mA to 1 mA","cmc":"2,7·10⁻⁴ · I + 0,02 µA"},{"name":"40 Hz 至 5000 Hz","range":"1 mA to 10 mA","cmc":"2,7·10⁻⁴ · I + 0,14 µA"},{"name":"40 Hz 至 5000 Hz","range":"10 mA to 100 mA","cmc":"2,7·10⁻⁴ · I + 1,4 µA"},{"name":"40 Hz 至 5000 Hz","range":"0,1 A to 1 A","cmc":"0,075 %"},{"name":"40 Hz 至 5000 Hz","range":"1 A to 10 A","cmc":"0,12 %"}],"reference_zh":"内部程序 PT 403 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"交流电流","search_zh":"校准器 发生器 电源 校准 — 交流电流 内部程序；在固定地点 (S) 交流电流 内部程序 在固定地点 (S) 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 内部程序 PT 403 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器\n发生器\n电源","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"40 Hz až 5000 Hz","range":"10 µA to 100 µA","cmc":"1,7·10⁻⁴ · I + 19 nA"},{"name":"40 Hz až 5000 Hz","range":"0,1 mA to 1 mA","cmc":"2,7·10⁻⁴ · I + 0,02 µA"},{"name":"40 Hz až 5000 Hz","range":"1 mA to 10 mA","cmc":"2,7·10⁻⁴ · I + 0,14 µA"},{"name":"40 Hz až 5000 Hz","range":"10 mA to 100 mA","cmc":"2,7·10⁻⁴ · I + 1,4 µA"},{"name":"40 Hz až 5000 Hz","range":"0,1 A to 1 A","cmc":"0,075 %"},{"name":"40 Hz až 5000 Hz","range":"1 A to 10 A","cmc":"0,12 %"}],"reference_cs":"Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Proud AC","search_cs":"Kalibrátory Generátory Napájecí zdroje Kalibrace — Proud AC Vnitřní postup; Ve stálé lokalitě (S) Proud AC Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nGenerátory\nNapájecí zdroje"},{"_id":"1421661cb53a64f9cbb73fb1","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kalibratory\nGeneratory\nZasilacze","test_object_en":"Calibrators\nGenerators\nPower supplies","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"40 Hz do 5000 Hz","range":"0,1 mA do 20 mA","cmc":"2 µA"},{"name":"40 Hz do 5000 Hz","range":"20 mA do 200 mA","cmc":"0,02 mA"},{"name":"40 Hz do 5000 Hz","range":"0,2 A do 2 A","cmc":"0,15 mA"},{"name":"40 Hz do 5000 Hz","range":"2 A do 10 A","cmc":"1 mA"}],"parameters_en":[{"name":"40 Hz to 5000 Hz","range":"0,1 mA to 20 mA","cmc":"2 µA"},{"name":"40 Hz to 5000 Hz","range":"20 mA to 200 mA","cmc":"0,02 mA"},{"name":"40 Hz to 5000 Hz","range":"0,2 A to 2 A","cmc":"0,15 mA"},{"name":"40 Hz to 5000 Hz","range":"2 A to 10 A","cmc":"1 mA"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 5000 Hz 0,1 mA do 20 mA CMC 2 µA\n40 Hz do 5000 Hz 20 mA do 200 mA CMC 0,02 mA\n40 Hz do 5000 Hz 0,2 A do 2 A CMC 0,15 mA\n40 Hz do 5000 Hz 2 A do 10 A CMC 1 mA\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 403","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"P","note":"I – wartość mierzona (A)","note_en":"I – measured value (A)","search_text":"Kalibratory\nGeneratory\nZasilacze Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 5000 Hz 0,1 mA do 20 mA CMC 2 µA\n40 Hz do 5000 Hz 20 mA do 200 mA CMC 0,02 mA\n40 Hz do 5000 Hz 0,2 A do 2 A CMC 0,15 mA\n40 Hz do 5000 Hz 2 A do 10 A CMC 1 mA\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0 Kalibratory\nGeneratory\nZasilacze Wzorcowanie — Prad AC\nZakres:\n40 Hz do 5000 Hz 0,1 mA do 20 mA CMC 2 µA\n40 Hz do 5000 Hz 20 mA do 200 mA CMC 0,02 mA\n40 Hz do 5000 Hz 0,2 A do 2 A CMC 0,15 mA\n40 Hz do 5000 Hz 2 A do 10 A CMC 1 mA\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 403 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Calibrators Generators Power supplies Calibration — AC current Internal procedure; Outside of permanent location (P) AC current Internal procedure Outside of permanent location (P) 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz 40 Hz to 5000 Hz Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":23,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 403 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"40 Hz bis 5000 Hz","range":"0,1 mA to 20 mA","cmc":"2 µA"},{"name":"40 Hz bis 5000 Hz","range":"20 mA to 200 mA","cmc":"0,02 mA"},{"name":"40 Hz bis 5000 Hz","range":"0,2 A to 2 A","cmc":"0,15 mA"},{"name":"40 Hz bis 5000 Hz","range":"2 A to 10 A","cmc":"1 mA"}],"reference_de":"Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"AC-Strom","search_de":"Kalibratoren Generatoren Netzgeräte Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) AC-Strom Internes Verfahren Außerhalb des festen Standorts (P) 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz 40 Hz bis 5000 Hz Internes Verfahren PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Kalibratoren\nGeneratoren\nNetzgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"40 Hz 至 5000 Hz","range":"0,1 mA to 20 mA","cmc":"2 µA"},{"name":"40 Hz 至 5000 Hz","range":"20 mA to 200 mA","cmc":"0,02 mA"},{"name":"40 Hz 至 5000 Hz","range":"0,2 A to 2 A","cmc":"0,15 mA"},{"name":"40 Hz 至 5000 Hz","range":"2 A to 10 A","cmc":"1 mA"}],"reference_zh":"内部程序 PT 403 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"交流电流","search_zh":"校准器 发生器 电源 校准 — 交流电流 内部程序；固定地点以外 (P) 交流电流 内部程序 固定地点以外 (P) 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 40 Hz 至 5000 Hz 内部程序 PT 403 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"校准器\n发生器\n电源","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"40 Hz až 5000 Hz","range":"0,1 mA to 20 mA","cmc":"2 µA"},{"name":"40 Hz až 5000 Hz","range":"20 mA to 200 mA","cmc":"0,02 mA"},{"name":"40 Hz až 5000 Hz","range":"0,2 A to 2 A","cmc":"0,15 mA"},{"name":"40 Hz až 5000 Hz","range":"2 A to 10 A","cmc":"1 mA"}],"reference_cs":"Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Proud AC","search_cs":"Kalibrátory Generátory Napájecí zdroje Kalibrace — Proud AC Vnitřní postup; Mimo stálé pracoviště (P) Proud AC Vnitřní postup Mimo stálou lokalitu (P) 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz 40 Hz až 5000 Hz Vnitřní postup PT 403 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Kalibrátory\nGenerátory\nNapájecí zdroje"},{"_id":"31ebfa6490edcec6dfb1983f","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Mierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMultimetry\nPrzetworniki","test_object_en":"Analogue ohmmeters\nDigital ohmmeters\nMultimeters\nTransmitters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0,001 Ω do 1 Ω","cmc":"2,0·10⁻⁵ · R + 0,6 µΩ"},{"name":"","range":"1 Ω do 10 Ω","cmc":"2,0·10⁻⁵ · R + 1 µΩ"},{"name":"","range":"10 Ω do 100 Ω","cmc":"2,0·10⁻⁵ · R + 0,01 mΩ"},{"name":"","range":"0,1 kΩ do 1 kΩ","cmc":"0,002 %"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"0,003 %"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"0,003 %"},{"name":"","range":"0,1 MΩ do 1 MΩ","cmc":"0,004 %"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"0,008 %"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"0,07 %"},{"name":"","range":"0,1 GΩ do 100 GΩ","cmc":"0,6 %"}],"parameters_en":[{"name":"","range":"0,001 Ω to 1 Ω","cmc":"2,0·10⁻⁵ · R + 0,6 µΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"2,0·10⁻⁵ · R + 1 µΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"2,0·10⁻⁵ · R + 0,01 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,002 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,003 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,003 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,004 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,008 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,07 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"0,6 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 1 Ω CMC 2,0·10⁻⁵ · R + 0,6 µΩ\n1 Ω do 10 Ω CMC 2,0·10⁻⁵ · R + 1 µΩ\n10 Ω do 100 Ω CMC 2,0·10⁻⁵ · R + 0,01 mΩ\n0,1 kΩ do 1 kΩ CMC 0,002 %\n1 kΩ do 10 kΩ CMC 0,003 %\n10 kΩ do 100 kΩ CMC 0,003 %\n0,1 MΩ do 1 MΩ CMC 0,004 %\n1 MΩ do 10 MΩ CMC 0,008 %\n10 MΩ do 100 MΩ CMC 0,07 %\n0,1 GΩ do 100 GΩ CMC 0,6 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 401","norm_bases":["PT 401"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":"R – wartość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Mierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMultimetry\nPrzetworniki Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 1 Ω CMC 2,0·10⁻⁵ · R + 0,6 µΩ\n1 Ω do 10 Ω CMC 2,0·10⁻⁵ · R + 1 µΩ\n10 Ω do 100 Ω CMC 2,0·10⁻⁵ · R + 0,01 mΩ\n0,1 kΩ do 1 kΩ CMC 0,002 %\n1 kΩ do 10 kΩ CMC 0,003 %\n10 kΩ do 100 kΩ CMC 0,003 %\n0,1 MΩ do 1 MΩ CMC 0,004 %\n1 MΩ do 10 MΩ CMC 0,008 %\n10 MΩ do 100 MΩ CMC 0,07 %\n0,1 GΩ do 100 GΩ CMC 0,6 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 401 Mierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMultimetry\nPrzetworniki Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 1 Ω CMC 2,0·10⁻⁵ · R + 0,6 µΩ\n1 Ω do 10 Ω CMC 2,0·10⁻⁵ · R + 1 µΩ\n10 Ω do 100 Ω CMC 2,0·10⁻⁵ · R + 0,01 mΩ\n0,1 kΩ do 1 kΩ CMC 0,002 %\n1 kΩ do 10 kΩ CMC 0,003 %\n10 kΩ do 100 kΩ CMC 0,003 %\n0,1 MΩ do 1 MΩ CMC 0,004 %\n1 MΩ do 10 MΩ CMC 0,008 %\n10 MΩ do 100 MΩ CMC 0,07 %\n0,1 GΩ do 100 GΩ CMC 0,6 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 401","search_en":"Analogue ohmmeters Digital ohmmeters Multimeters Transmitters Calibration — DC resistance Internal procedure; Direct method; At permanent location (S) DC resistance Internal procedure Direct method At permanent location (S) Internal procedure PT 401","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":24,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 401","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0,001 Ω to 1 Ω","cmc":"2,0·10⁻⁵ · R + 0,6 µΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"2,0·10⁻⁵ · R + 1 µΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"2,0·10⁻⁵ · R + 0,01 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,002 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,003 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,003 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,004 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,008 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,07 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"0,6 %"}],"reference_de":"Internes Verfahren PT 401","regulatory_area_de":"DC-Widerstand","search_de":"Analoge Widerstandsmessgeräte Digitale Widerstandsmessgeräte Multimeter Messumformer Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PT 401","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Widerstandsmessgeräte\nDigitale Widerstandsmessgeräte\nMultimeter\nMessumformer","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0,001 Ω to 1 Ω","cmc":"2,0·10⁻⁵ · R + 0,6 µΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"2,0·10⁻⁵ · R + 1 µΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"2,0·10⁻⁵ · R + 0,01 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,002 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,003 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,003 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,004 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,008 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,07 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"0,6 %"}],"reference_zh":"内部程序 PT 401","regulatory_area_zh":"直流电阻","search_zh":"模拟式电阻表 数字电阻测量仪 万用表 变送器 校准 — 直流电阻 内部程序；直接法；在固定地点 (S) 直流电阻 内部程序 直接法 在固定地点 (S) 内部程序 PT 401","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"模拟式电阻表\n数字电阻测量仪\n万用表\n变送器","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0,001 Ω to 1 Ω","cmc":"2,0·10⁻⁵ · R + 0,6 µΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"2,0·10⁻⁵ · R + 1 µΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"2,0·10⁻⁵ · R + 0,01 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,002 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,003 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,003 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,004 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,008 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,07 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"0,6 %"}],"reference_cs":"Vnitřní postup PT 401","regulatory_area_cs":"Odpor DC","search_cs":"Analogové měřiče odporu Digitální měřiče odporu Multimetry Snímače Kalibrace — Odpor DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 401","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče odporu\nDigitální měřiče odporu\nMultimetry\nSnímače"},{"_id":"09149014ae3e53a96f088c77","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Mierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMultimetry\nPrzetworniki","test_object_en":"Analogue ohmmeters\nDigital ohmmeters\nMultimeters\nTransmitters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0,001 Ω do 100 Ω","cmc":"1,2·10⁻⁴ · R + 0,005 Ω"},{"name":"","range":"0,1 kΩ do 1 kΩ","cmc":"0,023 %"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"0,023 %"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"0,023 %"},{"name":"","range":"0,1 MΩ do 1 MΩ","cmc":"0,023 %"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"0,06 %"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"0,4 %"},{"name":"","range":"0,1 GΩ do 100 GΩ","cmc":"1,8 %"}],"parameters_en":[{"name":"","range":"0,001 Ω to 100 Ω","cmc":"1,2·10⁻⁴ · R + 0,005 Ω"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,023 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,023 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,023 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,023 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,06 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,4 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"1,8 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 100 Ω CMC 1,2·10⁻⁴ · R + 0,005 Ω\n0,1 kΩ do 1 kΩ CMC 0,023 %\n1 kΩ do 10 kΩ CMC 0,023 %\n10 kΩ do 100 kΩ CMC 0,023 %\n0,1 MΩ do 1 MΩ CMC 0,023 %\n1 MΩ do 10 MΩ CMC 0,06 %\n10 MΩ do 100 MΩ CMC 0,4 %\n0,1 GΩ do 100 GΩ CMC 1,8 %\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 401","norm_bases":["PT 401"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"P","note":"R – wartość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Mierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMultimetry\nPrzetworniki Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 100 Ω CMC 1,2·10⁻⁴ · R + 0,005 Ω\n0,1 kΩ do 1 kΩ CMC 0,023 %\n1 kΩ do 10 kΩ CMC 0,023 %\n10 kΩ do 100 kΩ CMC 0,023 %\n0,1 MΩ do 1 MΩ CMC 0,023 %\n1 MΩ do 10 MΩ CMC 0,06 %\n10 MΩ do 100 MΩ CMC 0,4 %\n0,1 GΩ do 100 GΩ CMC 1,8 %\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 401 Mierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMultimetry\nPrzetworniki Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 100 Ω CMC 1,2·10⁻⁴ · R + 0,005 Ω\n0,1 kΩ do 1 kΩ CMC 0,023 %\n1 kΩ do 10 kΩ CMC 0,023 %\n10 kΩ do 100 kΩ CMC 0,023 %\n0,1 MΩ do 1 MΩ CMC 0,023 %\n1 MΩ do 10 MΩ CMC 0,06 %\n10 MΩ do 100 MΩ CMC 0,4 %\n0,1 GΩ do 100 GΩ CMC 1,8 %\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 401","search_en":"Analogue ohmmeters Digital ohmmeters Multimeters Transmitters Calibration — DC resistance Internal procedure; Direct method; Outside of permanent location (P) DC resistance Internal procedure Direct method Outside of permanent location (P) Internal procedure PT 401","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":25,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 401","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0,001 Ω to 100 Ω","cmc":"1,2·10⁻⁴ · R + 0,005 Ω"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,023 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,023 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,023 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,023 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,06 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,4 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"1,8 %"}],"reference_de":"Internes Verfahren PT 401","regulatory_area_de":"DC-Widerstand","search_de":"Analoge Widerstandsmessgeräte Digitale Widerstandsmessgeräte Multimeter Messumformer Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) DC-Widerstand Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 401","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Analoge Widerstandsmessgeräte\nDigitale Widerstandsmessgeräte\nMultimeter\nMessumformer","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0,001 Ω to 100 Ω","cmc":"1,2·10⁻⁴ · R + 0,005 Ω"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,023 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,023 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,023 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,023 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,06 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,4 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"1,8 %"}],"reference_zh":"内部程序 PT 401","regulatory_area_zh":"直流电阻","search_zh":"模拟式电阻表 数字电阻测量仪 万用表 变送器 校准 — 直流电阻 内部程序；直接法；固定地点以外 (P) 直流电阻 内部程序 直接法 固定地点以外 (P) 内部程序 PT 401","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"模拟式电阻表\n数字电阻测量仪\n万用表\n变送器","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0,001 Ω to 100 Ω","cmc":"1,2·10⁻⁴ · R + 0,005 Ω"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,023 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,023 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,023 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,023 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,06 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,4 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"1,8 %"}],"reference_cs":"Vnitřní postup PT 401","regulatory_area_cs":"Odpor DC","search_cs":"Analogové měřiče odporu Digitální měřiče odporu Multimetry Snímače Kalibrace — Odpor DC Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Odpor DC Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 401","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Analogové měřiče odporu\nDigitální měřiče odporu\nMultimetry\nSnímače"},{"_id":"f956c761f97e3ad4be709fb3","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kalibratory rezystancji\nMierniki parametrów sieci\nMierniki rezystancji izolacji","test_object_en":"Resistance calibrators\nPower network parameter meters\nInsulation resistance meters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0,001 Ω do 1 Ω","cmc":"2,0·10⁻⁵ · R + 0,6 µΩ"},{"name":"","range":"1 Ω do 10 Ω","cmc":"2,0·10⁻⁵ · R + 1 µΩ"},{"name":"","range":"10 Ω do 100 Ω","cmc":"2,0·10⁻⁵ · R + 0,01 mΩ"},{"name":"","range":"0,1 kΩ do 1 kΩ","cmc":"0,002 %"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"0,003 %"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"0,003 %"},{"name":"","range":"0,1 MΩ do 1 MΩ","cmc":"0,004 %"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"0,008 %"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"0,07 %"},{"name":"","range":"0,1 GΩ do 100 GΩ","cmc":"0,6 %"}],"parameters_en":[{"name":"","range":"0,001 Ω to 1 Ω","cmc":"2,0·10⁻⁵ · R + 0,6 µΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"2,0·10⁻⁵ · R + 1 µΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"2,0·10⁻⁵ · R + 0,01 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,002 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,003 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,003 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,004 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,008 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,07 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"0,6 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 1 Ω CMC 2,0·10⁻⁵ · R + 0,6 µΩ\n1 Ω do 10 Ω CMC 2,0·10⁻⁵ · R + 1 µΩ\n10 Ω do 100 Ω CMC 2,0·10⁻⁵ · R + 0,01 mΩ\n0,1 kΩ do 1 kΩ CMC 0,002 %\n1 kΩ do 10 kΩ CMC 0,003 %\n10 kΩ do 100 kΩ CMC 0,003 %\n0,1 MΩ do 1 MΩ CMC 0,004 %\n1 MΩ do 10 MΩ CMC 0,008 %\n10 MΩ do 100 MΩ CMC 0,07 %\n0,1 GΩ do 100 GΩ CMC 0,6 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 402, PT 403 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","PT 403","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":"R – wartość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Kalibratory rezystancji\nMierniki parametrów sieci\nMierniki rezystancji izolacji Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 1 Ω CMC 2,0·10⁻⁵ · R + 0,6 µΩ\n1 Ω do 10 Ω CMC 2,0·10⁻⁵ · R + 1 µΩ\n10 Ω do 100 Ω CMC 2,0·10⁻⁵ · R + 0,01 mΩ\n0,1 kΩ do 1 kΩ CMC 0,002 %\n1 kΩ do 10 kΩ CMC 0,003 %\n10 kΩ do 100 kΩ CMC 0,003 %\n0,1 MΩ do 1 MΩ CMC 0,004 %\n1 MΩ do 10 MΩ CMC 0,008 %\n10 MΩ do 100 MΩ CMC 0,07 %\n0,1 GΩ do 100 GΩ CMC 0,6 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 402, PT 403 w oparciu o EURAMET cg-15 v. 3.0 Kalibratory rezystancji\nMierniki parametrow sieci\nMierniki rezystancji izolacji Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 1 Ω CMC 2,0·10⁻⁵ · R + 0,6 µΩ\n1 Ω do 10 Ω CMC 2,0·10⁻⁵ · R + 1 µΩ\n10 Ω do 100 Ω CMC 2,0·10⁻⁵ · R + 0,01 mΩ\n0,1 kΩ do 1 kΩ CMC 0,002 %\n1 kΩ do 10 kΩ CMC 0,003 %\n10 kΩ do 100 kΩ CMC 0,003 %\n0,1 MΩ do 1 MΩ CMC 0,004 %\n1 MΩ do 10 MΩ CMC 0,008 %\n10 MΩ do 100 MΩ CMC 0,07 %\n0,1 GΩ do 100 GΩ CMC 0,6 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 402, PT 403 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Resistance calibrators Power network parameter meters Insulation resistance meters Calibration — DC resistance Internal procedure; At permanent location (S) DC resistance Internal procedure At permanent location (S) Internal procedure PT 402, PT 403 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":26,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402, PT 403 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0,001 Ω to 1 Ω","cmc":"2,0·10⁻⁵ · R + 0,6 µΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"2,0·10⁻⁵ · R + 1 µΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"2,0·10⁻⁵ · R + 0,01 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,002 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,003 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,003 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,004 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,008 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,07 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"0,6 %"}],"reference_de":"Internes Verfahren PT 402, PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"DC-Widerstand","search_de":"Widerstandskalibratoren Netzparametermessgeräte Isolationswiderstandsmessgeräte Kalibrierung — DC-Widerstand Internes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Am festen Standort (S) Internes Verfahren PT 402, PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Widerstandskalibratoren\nNetzparametermessgeräte\nIsolationswiderstandsmessgeräte","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0,001 Ω to 1 Ω","cmc":"2,0·10⁻⁵ · R + 0,6 µΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"2,0·10⁻⁵ · R + 1 µΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"2,0·10⁻⁵ · R + 0,01 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,002 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,003 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,003 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,004 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,008 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,07 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"0,6 %"}],"reference_zh":"内部程序 PT 402, PT 403 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"直流电阻","search_zh":"电阻校准器 电网参数测量仪 绝缘电阻测量仪 校准 — 直流电阻 内部程序；在固定地点 (S) 直流电阻 内部程序 在固定地点 (S) 内部程序 PT 402, PT 403 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电阻校准器\n电网参数测量仪\n绝缘电阻测量仪","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0,001 Ω to 1 Ω","cmc":"2,0·10⁻⁵ · R + 0,6 µΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"2,0·10⁻⁵ · R + 1 µΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"2,0·10⁻⁵ · R + 0,01 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,002 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,003 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,003 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,004 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,008 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,07 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"0,6 %"}],"reference_cs":"Vnitřní postup PT 402, PT 403 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Odpor DC","search_cs":"Kalibrátory odporu Měřiče parametrů sítě Měřiče izolačního odporu Kalibrace — Odpor DC Vnitřní postup; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PT 402, PT 403 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory odporu\nMěřiče parametrů sítě\nMěřiče izolačního odporu"},{"_id":"2264f8986cd53e50e9dd4d07","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kalibratory rezystancji\nMierniki parametrów sieci\nMierniki rezystancji izolacji","test_object_en":"Resistance calibrators\nPower network parameter meters\nInsulation resistance meters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0,001 Ω do 100 Ω","cmc":"1,2·10⁻⁴ · R + 0,005 Ω"},{"name":"","range":"0,1 kΩ do 1 kΩ","cmc":"0,023 %"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"0,023 %"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"0,023 %"},{"name":"","range":"0,1 MΩ do 1 MΩ","cmc":"0,023 %"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"0,06 %"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"0,4 %"},{"name":"","range":"0,1 GΩ do 100 GΩ","cmc":"1,8 %"}],"parameters_en":[{"name":"","range":"0,001 Ω to 100 Ω","cmc":"1,2·10⁻⁴ · R + 0,005 Ω"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,023 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,023 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,023 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,023 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,06 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,4 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"1,8 %"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 100 Ω CMC 1,2·10⁻⁴ · R + 0,005 Ω\n0,1 kΩ do 1 kΩ CMC 0,023 %\n1 kΩ do 10 kΩ CMC 0,023 %\n10 kΩ do 100 kΩ CMC 0,023 %\n0,1 MΩ do 1 MΩ CMC 0,023 %\n1 MΩ do 10 MΩ CMC 0,06 %\n10 MΩ do 100 MΩ CMC 0,4 %\n0,1 GΩ do 100 GΩ CMC 1,8 %\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 402, PT 403 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["PT 402","PT 403","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"P","note":"R – wartość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Kalibratory rezystancji\nMierniki parametrów sieci\nMierniki rezystancji izolacji Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 100 Ω CMC 1,2·10⁻⁴ · R + 0,005 Ω\n0,1 kΩ do 1 kΩ CMC 0,023 %\n1 kΩ do 10 kΩ CMC 0,023 %\n10 kΩ do 100 kΩ CMC 0,023 %\n0,1 MΩ do 1 MΩ CMC 0,023 %\n1 MΩ do 10 MΩ CMC 0,06 %\n10 MΩ do 100 MΩ CMC 0,4 %\n0,1 GΩ do 100 GΩ CMC 1,8 %\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 402, PT 403 w oparciu o EURAMET cg-15 v. 3.0 Kalibratory rezystancji\nMierniki parametrow sieci\nMierniki rezystancji izolacji Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 100 Ω CMC 1,2·10⁻⁴ · R + 0,005 Ω\n0,1 kΩ do 1 kΩ CMC 0,023 %\n1 kΩ do 10 kΩ CMC 0,023 %\n10 kΩ do 100 kΩ CMC 0,023 %\n0,1 MΩ do 1 MΩ CMC 0,023 %\n1 MΩ do 10 MΩ CMC 0,06 %\n10 MΩ do 100 MΩ CMC 0,4 %\n0,1 GΩ do 100 GΩ CMC 1,8 %\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 402, PT 403 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Resistance calibrators Power network parameter meters Insulation resistance meters Calibration — DC resistance Internal procedure; Outside of permanent location (P) DC resistance Internal procedure Outside of permanent location (P) Internal procedure PT 402, PT 403 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":27,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402, PT 403 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0,001 Ω to 100 Ω","cmc":"1,2·10⁻⁴ · R + 0,005 Ω"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,023 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,023 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,023 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,023 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,06 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,4 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"1,8 %"}],"reference_de":"Internes Verfahren PT 402, PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"DC-Widerstand","search_de":"Widerstandskalibratoren Netzparametermessgeräte Isolationswiderstandsmessgeräte Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) DC-Widerstand Internes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 402, PT 403 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Widerstandskalibratoren\nNetzparametermessgeräte\nIsolationswiderstandsmessgeräte","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0,001 Ω to 100 Ω","cmc":"1,2·10⁻⁴ · R + 0,005 Ω"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,023 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,023 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,023 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,023 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,06 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,4 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"1,8 %"}],"reference_zh":"内部程序 PT 402, PT 403 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"直流电阻","search_zh":"电阻校准器 电网参数测量仪 绝缘电阻测量仪 校准 — 直流电阻 内部程序；固定地点以外 (P) 直流电阻 内部程序 固定地点以外 (P) 内部程序 PT 402, PT 403 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"电阻校准器\n电网参数测量仪\n绝缘电阻测量仪","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0,001 Ω to 100 Ω","cmc":"1,2·10⁻⁴ · R + 0,005 Ω"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"0,023 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,023 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,023 %"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"0,023 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,06 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,4 %"},{"name":"","range":"0,1 GΩ to 100 GΩ","cmc":"1,8 %"}],"reference_cs":"Vnitřní postup PT 402, PT 403 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Odpor DC","search_cs":"Kalibrátory odporu Měřiče parametrů sítě Měřiče izolačního odporu Kalibrace — Odpor DC Vnitřní postup; Mimo stálé pracoviště (P) Odpor DC Vnitřní postup Mimo stálou lokalitu (P) Vnitřní postup PT 402, PT 403 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Kalibrátory odporu\nMěřiče parametrů sítě\nMěřiče izolačního odporu"},{"_id":"466aa241234fa3e996d8034e","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Rezystory stałe\nRezystory regulowane\nWzorce rezystancji\nBoczniki","test_object_en":"Fixed resistors\nVariable resistors\nResistance standards\nShunts","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0,001 Ω do 0,1 Ω","cmc":"5,0·10⁻³ · R + 0,1 µΩ"},{"name":"","range":"0,1 Ω do 10 Ω","cmc":"6,0·10⁻⁵ · R + 0,02 mΩ"},{"name":"","range":"10 Ω do 100 Ω","cmc":"6,0·10⁻⁵ · R + 0,3 mΩ"},{"name":"","range":"0,1 kΩ do 1 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"0,1 MΩ do 1 MΩ","cmc":"7,0·10⁻⁵ · R"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"1,0·10⁻⁴ · R"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"6,0·10⁻⁴ · R"},{"name":"","range":"100 MΩ do 1000 MΩ","cmc":"2,0·10⁻³ · R"},{"name":"","range":"1 GΩ do 2 GΩ","cmc":"2,0·10⁻³ · R"},{"name":"","range":"2 GΩ do 20 GΩ","cmc":"5,0·10⁻³ · R"},{"name":"","range":"20 GΩ do 100 GΩ","cmc":"5,0·10⁻³ · R"}],"parameters_en":[{"name":"","range":"0,001 Ω to 0,1 Ω","cmc":"5,0·10⁻³ · R + 0,1 µΩ"},{"name":"","range":"0,1 Ω to 10 Ω","cmc":"6,0·10⁻⁵ · R + 0,02 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"6,0·10⁻⁵ · R + 0,3 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"7,0·10⁻⁵ · R"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"1,0·10⁻⁴ · R"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"6,0·10⁻⁴ · R"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"2,0·10⁻³ · R"},{"name":"","range":"1 GΩ to 2 GΩ","cmc":"2,0·10⁻³ · R"},{"name":"","range":"2 GΩ to 20 GΩ","cmc":"5,0·10⁻³ · R"},{"name":"","range":"20 GΩ to 100 GΩ","cmc":"5,0·10⁻³ · R"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct and indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct and indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 0,1 Ω CMC 5,0·10⁻³ · R + 0,1 µΩ\n0,1 Ω do 10 Ω CMC 6,0·10⁻⁵ · R + 0,02 mΩ\n10 Ω do 100 Ω CMC 6,0·10⁻⁵ · R + 0,3 mΩ\n0,1 kΩ do 1 kΩ CMC 6,0·10⁻⁵ · R\n1 kΩ do 10 kΩ CMC 6,0·10⁻⁵ · R\n10 kΩ do 100 kΩ CMC 6,0·10⁻⁵ · R\n0,1 MΩ do 1 MΩ CMC 7,0·10⁻⁵ · R\n1 MΩ do 10 MΩ CMC 1,0·10⁻⁴ · R\n10 MΩ do 100 MΩ CMC 6,0·10⁻⁴ · R\n100 MΩ do 1000 MΩ CMC 2,0·10⁻³ · R\n1 GΩ do 2 GΩ CMC 2,0·10⁻³ · R\n2 GΩ do 20 GΩ CMC 5,0·10⁻³ · R\n20 GΩ do 100 GΩ CMC 5,0·10⁻³ · R\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 404","norm_bases":["PT 404"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":"R – wartość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Rezystory stałe\nRezystory regulowane\nWzorce rezystancji\nBoczniki Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 0,1 Ω CMC 5,0·10⁻³ · R + 0,1 µΩ\n0,1 Ω do 10 Ω CMC 6,0·10⁻⁵ · R + 0,02 mΩ\n10 Ω do 100 Ω CMC 6,0·10⁻⁵ · R + 0,3 mΩ\n0,1 kΩ do 1 kΩ CMC 6,0·10⁻⁵ · R\n1 kΩ do 10 kΩ CMC 6,0·10⁻⁵ · R\n10 kΩ do 100 kΩ CMC 6,0·10⁻⁵ · R\n0,1 MΩ do 1 MΩ CMC 7,0·10⁻⁵ · R\n1 MΩ do 10 MΩ CMC 1,0·10⁻⁴ · R\n10 MΩ do 100 MΩ CMC 6,0·10⁻⁴ · R\n100 MΩ do 1000 MΩ CMC 2,0·10⁻³ · R\n1 GΩ do 2 GΩ CMC 2,0·10⁻³ · R\n2 GΩ do 20 GΩ CMC 5,0·10⁻³ · R\n20 GΩ do 100 GΩ CMC 5,0·10⁻³ · R\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 404 Rezystory stale\nRezystory regulowane\nWzorce rezystancji\nBoczniki Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 0,1 Ω CMC 5,0·10⁻³ · R + 0,1 µΩ\n0,1 Ω do 10 Ω CMC 6,0·10⁻⁵ · R + 0,02 mΩ\n10 Ω do 100 Ω CMC 6,0·10⁻⁵ · R + 0,3 mΩ\n0,1 kΩ do 1 kΩ CMC 6,0·10⁻⁵ · R\n1 kΩ do 10 kΩ CMC 6,0·10⁻⁵ · R\n10 kΩ do 100 kΩ CMC 6,0·10⁻⁵ · R\n0,1 MΩ do 1 MΩ CMC 7,0·10⁻⁵ · R\n1 MΩ do 10 MΩ CMC 1,0·10⁻⁴ · R\n10 MΩ do 100 MΩ CMC 6,0·10⁻⁴ · R\n100 MΩ do 1000 MΩ CMC 2,0·10⁻³ · R\n1 GΩ do 2 GΩ CMC 2,0·10⁻³ · R\n2 GΩ do 20 GΩ CMC 5,0·10⁻³ · R\n20 GΩ do 100 GΩ CMC 5,0·10⁻³ · R\nProcedura wewnetrzna; Metoda bezposrednia i posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 404","search_en":"Fixed resistors Variable resistors Resistance standards Shunts Calibration — DC resistance Internal procedure; Direct and indirect method; At permanent location (S) DC resistance Internal procedure Direct and indirect method At permanent location (S) Internal procedure PT 404","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":28,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 404","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0,001 Ω to 0,1 Ω","cmc":"5,0·10⁻³ · R + 0,1 µΩ"},{"name":"","range":"0,1 Ω to 10 Ω","cmc":"6,0·10⁻⁵ · R + 0,02 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"6,0·10⁻⁵ · R + 0,3 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"7,0·10⁻⁵ · R"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"1,0·10⁻⁴ · R"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"6,0·10⁻⁴ · R"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"2,0·10⁻³ · R"},{"name":"","range":"1 GΩ to 2 GΩ","cmc":"2,0·10⁻³ · R"},{"name":"","range":"2 GΩ to 20 GΩ","cmc":"5,0·10⁻³ · R"},{"name":"","range":"20 GΩ to 100 GΩ","cmc":"5,0·10⁻³ · R"}],"reference_de":"Internes Verfahren PT 404","regulatory_area_de":"DC-Widerstand","search_de":"Festwiderstände Einstellbare Widerstände Widerstandsnormale Shunts Kalibrierung — DC-Widerstand Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Direktes und indirektes Verfahren Am festen Standort (S) Internes Verfahren PT 404","technique_de":"Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes und indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Festwiderstände\nEinstellbare Widerstände\nWiderstandsnormale\nShunts","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0,001 Ω to 0,1 Ω","cmc":"5,0·10⁻³ · R + 0,1 µΩ"},{"name":"","range":"0,1 Ω to 10 Ω","cmc":"6,0·10⁻⁵ · R + 0,02 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"6,0·10⁻⁵ · R + 0,3 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"7,0·10⁻⁵ · R"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"1,0·10⁻⁴ · R"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"6,0·10⁻⁴ · R"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"2,0·10⁻³ · R"},{"name":"","range":"1 GΩ to 2 GΩ","cmc":"2,0·10⁻³ · R"},{"name":"","range":"2 GΩ to 20 GΩ","cmc":"5,0·10⁻³ · R"},{"name":"","range":"20 GΩ to 100 GΩ","cmc":"5,0·10⁻³ · R"}],"reference_zh":"内部程序 PT 404","regulatory_area_zh":"直流电阻","search_zh":"固定电阻器 可调电阻器 标准电阻 分流器 校准 — 直流电阻 内部程序；直接法和间接法；在固定地点 (S) 直流电阻 内部程序 直接法和间接法 在固定地点 (S) 内部程序 PT 404","technique_zh":"内部程序；直接法和间接法；在固定地点 (S)","techniques_zh":["内部程序","直接法和间接法","在固定地点 (S)"],"test_object_zh":"固定电阻器\n可调电阻器\n标准电阻\n分流器","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0,001 Ω to 0,1 Ω","cmc":"5,0·10⁻³ · R + 0,1 µΩ"},{"name":"","range":"0,1 Ω to 10 Ω","cmc":"6,0·10⁻⁵ · R + 0,02 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"6,0·10⁻⁵ · R + 0,3 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"7,0·10⁻⁵ · R"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"1,0·10⁻⁴ · R"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"6,0·10⁻⁴ · R"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"2,0·10⁻³ · R"},{"name":"","range":"1 GΩ to 2 GΩ","cmc":"2,0·10⁻³ · R"},{"name":"","range":"2 GΩ to 20 GΩ","cmc":"5,0·10⁻³ · R"},{"name":"","range":"20 GΩ to 100 GΩ","cmc":"5,0·10⁻³ · R"}],"reference_cs":"Vnitřní postup PT 404","regulatory_area_cs":"Odpor DC","search_cs":"Pevné rezistory Nastavitelné rezistory Etalony odporu Bočníky Kalibrace — Odpor DC Vnitřní postup; Přímá a nepřímá metoda; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Přímá a nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 404","technique_cs":"Vnitřní postup; Přímá a nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá a nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Pevné rezistory\nNastavitelné rezistory\nEtalony odporu\nBočníky"},{"_id":"213ac1a2f893d02eb136a8fb","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Rezystory stałe\nRezystory regulowane\nWzorce rezystancji\nBoczniki","test_object_en":"Fixed resistors\nVariable resistors\nResistance standards\nShunts","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0,001 Ω do 0,1 Ω","cmc":"5,0·10⁻³ · R + 0,1 µΩ"},{"name":"","range":"0,1 Ω do 10 Ω","cmc":"6,0·10⁻⁵ · R + 0,02 mΩ"},{"name":"","range":"10 Ω do 100 Ω","cmc":"6,0·10⁻⁵ · R + 0,3 mΩ"},{"name":"","range":"0,1 kΩ do 1 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"0,1 MΩ do 1 MΩ","cmc":"7,0·10⁻⁵ · R"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"1,0·10⁻⁴ · R"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"6,0·10⁻⁴ · R"},{"name":"","range":"100 MΩ do 1000 MΩ","cmc":"2,0·10⁻³ · R"}],"parameters_en":[{"name":"","range":"0,001 Ω to 0,1 Ω","cmc":"5,0·10⁻³ · R + 0,1 µΩ"},{"name":"","range":"0,1 Ω to 10 Ω","cmc":"6,0·10⁻⁵ · R + 0,02 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"6,0·10⁻⁵ · R + 0,3 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"7,0·10⁻⁵ · R"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"1,0·10⁻⁴ · R"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"6,0·10⁻⁴ · R"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"2,0·10⁻³ · R"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia i pośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct and indirect method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia i pośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct and indirect method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 0,1 Ω CMC 5,0·10⁻³ · R + 0,1 µΩ\n0,1 Ω do 10 Ω CMC 6,0·10⁻⁵ · R + 0,02 mΩ\n10 Ω do 100 Ω CMC 6,0·10⁻⁵ · R + 0,3 mΩ\n0,1 kΩ do 1 kΩ CMC 6,0·10⁻⁵ · R\n1 kΩ do 10 kΩ CMC 6,0·10⁻⁵ · R\n10 kΩ do 100 kΩ CMC 6,0·10⁻⁵ · R\n0,1 MΩ do 1 MΩ CMC 7,0·10⁻⁵ · R\n1 MΩ do 10 MΩ CMC 1,0·10⁻⁴ · R\n10 MΩ do 100 MΩ CMC 6,0·10⁻⁴ · R\n100 MΩ do 1000 MΩ CMC 2,0·10⁻³ · R\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 404","norm_bases":["PT 404"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"P","note":"R – wartość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Rezystory stałe\nRezystory regulowane\nWzorce rezystancji\nBoczniki Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 0,1 Ω CMC 5,0·10⁻³ · R + 0,1 µΩ\n0,1 Ω do 10 Ω CMC 6,0·10⁻⁵ · R + 0,02 mΩ\n10 Ω do 100 Ω CMC 6,0·10⁻⁵ · R + 0,3 mΩ\n0,1 kΩ do 1 kΩ CMC 6,0·10⁻⁵ · R\n1 kΩ do 10 kΩ CMC 6,0·10⁻⁵ · R\n10 kΩ do 100 kΩ CMC 6,0·10⁻⁵ · R\n0,1 MΩ do 1 MΩ CMC 7,0·10⁻⁵ · R\n1 MΩ do 10 MΩ CMC 1,0·10⁻⁴ · R\n10 MΩ do 100 MΩ CMC 6,0·10⁻⁴ · R\n100 MΩ do 1000 MΩ CMC 2,0·10⁻³ · R\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 404 Rezystory stale\nRezystory regulowane\nWzorce rezystancji\nBoczniki Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 0,1 Ω CMC 5,0·10⁻³ · R + 0,1 µΩ\n0,1 Ω do 10 Ω CMC 6,0·10⁻⁵ · R + 0,02 mΩ\n10 Ω do 100 Ω CMC 6,0·10⁻⁵ · R + 0,3 mΩ\n0,1 kΩ do 1 kΩ CMC 6,0·10⁻⁵ · R\n1 kΩ do 10 kΩ CMC 6,0·10⁻⁵ · R\n10 kΩ do 100 kΩ CMC 6,0·10⁻⁵ · R\n0,1 MΩ do 1 MΩ CMC 7,0·10⁻⁵ · R\n1 MΩ do 10 MΩ CMC 1,0·10⁻⁴ · R\n10 MΩ do 100 MΩ CMC 6,0·10⁻⁴ · R\n100 MΩ do 1000 MΩ CMC 2,0·10⁻³ · R\nProcedura wewnetrzna; Metoda bezposrednia i posrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 404","search_en":"Fixed resistors Variable resistors Resistance standards Shunts Calibration — DC resistance Internal procedure; Direct and indirect method; Outside of permanent location (P) DC resistance Internal procedure Direct and indirect method Outside of permanent location (P) Internal procedure PT 404","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":29,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 404","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0,001 Ω to 0,1 Ω","cmc":"5,0·10⁻³ · R + 0,1 µΩ"},{"name":"","range":"0,1 Ω to 10 Ω","cmc":"6,0·10⁻⁵ · R + 0,02 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"6,0·10⁻⁵ · R + 0,3 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"7,0·10⁻⁵ · R"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"1,0·10⁻⁴ · R"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"6,0·10⁻⁴ · R"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"2,0·10⁻³ · R"}],"reference_de":"Internes Verfahren PT 404","regulatory_area_de":"DC-Widerstand","search_de":"Festwiderstände Einstellbare Widerstände Widerstandsnormale Shunts Kalibrierung — DC-Widerstand Internes Verfahren; Direktes und indirektes Verfahren; Außerhalb des festen Standorts (P) DC-Widerstand Internes Verfahren Direktes und indirektes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 404","technique_de":"Internes Verfahren; Direktes und indirektes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes und indirektes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Festwiderstände\nEinstellbare Widerstände\nWiderstandsnormale\nShunts","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0,001 Ω to 0,1 Ω","cmc":"5,0·10⁻³ · R + 0,1 µΩ"},{"name":"","range":"0,1 Ω to 10 Ω","cmc":"6,0·10⁻⁵ · R + 0,02 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"6,0·10⁻⁵ · R + 0,3 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"7,0·10⁻⁵ · R"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"1,0·10⁻⁴ · R"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"6,0·10⁻⁴ · R"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"2,0·10⁻³ · R"}],"reference_zh":"内部程序 PT 404","regulatory_area_zh":"直流电阻","search_zh":"固定电阻器 可调电阻器 标准电阻 分流器 校准 — 直流电阻 内部程序；直接法和间接法；固定地点以外 (P) 直流电阻 内部程序 直接法和间接法 固定地点以外 (P) 内部程序 PT 404","technique_zh":"内部程序；直接法和间接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法和间接法","固定地点以外 (P)"],"test_object_zh":"固定电阻器\n可调电阻器\n标准电阻\n分流器","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0,001 Ω to 0,1 Ω","cmc":"5,0·10⁻³ · R + 0,1 µΩ"},{"name":"","range":"0,1 Ω to 10 Ω","cmc":"6,0·10⁻⁵ · R + 0,02 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"6,0·10⁻⁵ · R + 0,3 mΩ"},{"name":"","range":"0,1 kΩ to 1 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"6,0·10⁻⁵ · R"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"7,0·10⁻⁵ · R"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"1,0·10⁻⁴ · R"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"6,0·10⁻⁴ · R"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"2,0·10⁻³ · R"}],"reference_cs":"Vnitřní postup PT 404","regulatory_area_cs":"Odpor DC","search_cs":"Pevné rezistory Nastavitelné rezistory Etalony odporu Bočníky Kalibrace — Odpor DC Vnitřní postup; Přímá a nepřímá metoda; Mimo stálou lokalitu (P) Odpor DC Vnitřní postup Přímá a nepřímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 404","technique_cs":"Vnitřní postup; Přímá a nepřímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá a nepřímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Pevné rezistory\nNastavitelné rezistory\nEtalony odporu\nBočníky"},{"_id":"479f1678597664875c2e2ef2","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Przetworniki temperatury","test_object_en":"Temperature transmitters","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electrical simulation of quantities","parameters":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,07 oC"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 oC"}],"parameters_en":[{"name":"","range":"-200 °C to 850 °C","cmc":"0,07 oC"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 oC"}],"technique":"Procedura wewnętrzna; Wzorcowanie metodą elektryczną; W stałej lokalizacji (S)","technique_en":"Internal procedure; Calibration by the electrical method; At permanent location (S)","techniques":["Procedura wewnętrzna","Wzorcowanie metodą elektryczną","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Calibration by the electrical method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-200 °C do 850 °C CMC 0,07 oC\n-200 °C do 1820 °C CMC 0,24 oC\nProcedura wewnętrzna; Wzorcowanie metodą elektryczną; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 401","norm_bases":["PT 401"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electrical simulation of quantities","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przetworniki temperatury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-200 °C do 850 °C CMC 0,07 oC\n-200 °C do 1820 °C CMC 0,24 oC\nProcedura wewnętrzna; Wzorcowanie metodą elektryczną; W stałej lokalizacji (S) Procedura wewnętrzna PT 401 Przetworniki temperatury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\n-200 °C do 850 °C CMC 0,07 oC\n-200 °C do 1820 °C CMC 0,24 oC\nProcedura wewnetrzna; Wzorcowanie metoda elektryczna; W stalej lokalizacji (S) Procedura wewnetrzna PT 401","search_en":"Temperature transmitters Calibration — Electrical simulation of quantities Internal procedure; Calibration by the electrical method; At permanent location (S) Electrical simulation of quantities Internal procedure Calibration by the electrical method At permanent location (S) Internal procedure PT 401","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":30,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 401","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-200 °C bis 850 °C","cmc":"0,07 oC"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 oC"}],"reference_de":"Internes Verfahren PT 401","regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturmessumformer Kalibrierung — Elektrische Simulation von Größen Internes Verfahren; Kalibrierung mit dem elektrischen Verfahren; Am festen Standort (S) Elektrische Simulation von Größen Internes Verfahren Kalibrierung mit dem elektrischen Verfahren Am festen Standort (S) Internes Verfahren PT 401","technique_de":"Internes Verfahren; Kalibrierung mit dem elektrischen Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Kalibrierung mit dem elektrischen Verfahren","Am festen Standort (S)"],"test_object_de":"Temperaturmessumformer","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-200 °C 至 850 °C","cmc":"0,07 oC"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 oC"}],"reference_zh":"内部程序 PT 401","regulatory_area_zh":"量值的电模拟","search_zh":"温度变送器 校准 — 物理量的电模拟 内部程序；电学法校准；在固定地点 (S) 量值的电模拟 内部程序 电学法校准 在固定地点 (S) 内部程序 PT 401","technique_zh":"内部程序；电学法校准；在固定地点 (S)","techniques_zh":["内部程序","电学法校准","在固定地点 (S)"],"test_object_zh":"温度变送器","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,07 oC"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 oC"}],"reference_cs":"Vnitřní postup PT 401","regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Převodníky teploty Kalibrace — Elektrická simulace veličin Vnitřní postup; Kalibrace elektrickou metodou; Ve stálé lokalitě (S) Elektrická simulace veličin Vnitřní postup Kalibrace elektrickou metodou Ve stálé lokalitě (S) Vnitřní postup PT 401","technique_cs":"Vnitřní postup; Kalibrace elektrickou metodou; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Kalibrace elektrickou metodou","Ve stálé lokalitě (S)"],"test_object_cs":"Převodníky teploty"},{"_id":"c182f261439ebd2f75865db5","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Przetworniki temperatury","test_object_en":"Temperature transmitters","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electrical simulation of quantities","parameters":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,36 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,98 °C"}],"parameters_en":[{"name":"","range":"-200 °C to 850 °C","cmc":"0,36 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,98 °C"}],"technique":"Procedura wewnętrzna; Wzorcowanie metodą elektryczną; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Calibration by the electrical method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Wzorcowanie metodą elektryczną","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Calibration by the electrical method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-200 °C do 850 °C CMC 0,36 °C\n-200 °C do 1820 °C CMC 0,98 °C\nProcedura wewnętrzna; Wzorcowanie metodą elektryczną; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 401","norm_bases":["PT 401"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electrical simulation of quantities","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Przetworniki temperatury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-200 °C do 850 °C CMC 0,36 °C\n-200 °C do 1820 °C CMC 0,98 °C\nProcedura wewnętrzna; Wzorcowanie metodą elektryczną; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 401 Przetworniki temperatury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\n-200 °C do 850 °C CMC 0,36 °C\n-200 °C do 1820 °C CMC 0,98 °C\nProcedura wewnetrzna; Wzorcowanie metoda elektryczna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 401","search_en":"Temperature transmitters Calibration — Electrical simulation of quantities Internal procedure; Calibration by the electrical method; Outside of permanent location (P) Electrical simulation of quantities Internal procedure Calibration by the electrical method Outside of permanent location (P) Internal procedure PT 401","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":31,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 401","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-200 °C bis 850 °C","cmc":"0,36 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,98 °C"}],"reference_de":"Internes Verfahren PT 401","regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturmessumformer Kalibrierung — Elektrische Simulation von Größen Internes Verfahren; Kalibrierung mit dem elektrischen Verfahren; Außerhalb des festen Standorts (P) Elektrische Simulation von Größen Internes Verfahren Kalibrierung mit dem elektrischen Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 401","technique_de":"Internes Verfahren; Kalibrierung mit dem elektrischen Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Kalibrierung mit dem elektrischen Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Temperaturmessumformer","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-200 °C 至 850 °C","cmc":"0,36 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,98 °C"}],"reference_zh":"内部程序 PT 401","regulatory_area_zh":"量值的电模拟","search_zh":"温度变送器 校准 — 物理量的电模拟 内部程序；电学法校准；固定地点以外 (P) 量值的电模拟 内部程序 电学法校准 固定地点以外 (P) 内部程序 PT 401","technique_zh":"内部程序；电学法校准；固定地点以外 (P)","techniques_zh":["内部程序","电学法校准","固定地点以外 (P)"],"test_object_zh":"温度变送器","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,36 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,98 °C"}],"reference_cs":"Vnitřní postup PT 401","regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Převodníky teploty Kalibrace — Elektrická simulace veličin Vnitřní postup; Kalibrace elektrickou metodou; Mimo stálou lokalitu (P) Elektrická simulace veličin Vnitřní postup Kalibrace elektrickou metodou Mimo stálou lokalitu (P) Vnitřní postup PT 401","technique_cs":"Vnitřní postup; Kalibrace elektrickou metodou; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Kalibrace elektrickou metodou","Mimo stálou lokalitu (P)"],"test_object_cs":"Převodníky teploty"},{"_id":"f9e15034f83eab69e2835e9a","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Wskaźniki (mierniki) temperatury (w tym regulatory temperatury)\nRejestratory temperatury","test_object_en":"Temperature indicators (meters) (including temperature controllers)\nTemperature recorders","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electrical simulation of quantities","parameters":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,07 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 °C"}],"parameters_en":[{"name":"","range":"-200 °C to 850 °C","cmc":"0,07 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 °C"}],"technique":"Procedura wewnętrzna; Wzorcowanie metodą elektryczną; W stałej lokalizacji (S)","technique_en":"Internal procedure; Calibration by the electrical method; At permanent location (S)","techniques":["Procedura wewnętrzna","Wzorcowanie metodą elektryczną","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Calibration by the electrical method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-200 °C do 850 °C CMC 0,07 °C\n-200 °C do 1820 °C CMC 0,24 °C\nProcedura wewnętrzna; Wzorcowanie metodą elektryczną; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 402","norm_bases":["PT 402"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electrical simulation of quantities","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wskaźniki (mierniki) temperatury (w tym regulatory temperatury)\nRejestratory temperatury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-200 °C do 850 °C CMC 0,07 °C\n-200 °C do 1820 °C CMC 0,24 °C\nProcedura wewnętrzna; Wzorcowanie metodą elektryczną; W stałej lokalizacji (S) Procedura wewnętrzna PT 402 Wskazniki (mierniki) temperatury (w tym regulatory temperatury)\nRejestratory temperatury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\n-200 °C do 850 °C CMC 0,07 °C\n-200 °C do 1820 °C CMC 0,24 °C\nProcedura wewnetrzna; Wzorcowanie metoda elektryczna; W stalej lokalizacji (S) Procedura wewnetrzna PT 402","search_en":"Temperature indicators (meters) (including temperature controllers) Temperature recorders Calibration — Electrical simulation of quantities Internal procedure; Calibration by the electrical method; At permanent location (S) Electrical simulation of quantities Internal procedure Calibration by the electrical method At permanent location (S) Internal procedure PT 402","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":32,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-200 °C bis 850 °C","cmc":"0,07 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 °C"}],"reference_de":"Internes Verfahren PT 402","regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturanzeiger (-messgeräte) (einschließlich Temperaturregler) Temperaturschreiber Kalibrierung — Elektrische Simulation von Größen Internes Verfahren; Kalibrierung mit dem elektrischen Verfahren; Am festen Standort (S) Elektrische Simulation von Größen Internes Verfahren Kalibrierung mit dem elektrischen Verfahren Am festen Standort (S) Internes Verfahren PT 402","technique_de":"Internes Verfahren; Kalibrierung mit dem elektrischen Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Kalibrierung mit dem elektrischen Verfahren","Am festen Standort (S)"],"test_object_de":"Temperaturanzeiger (-messgeräte) (einschließlich Temperaturregler)\nTemperaturschreiber","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-200 °C 至 850 °C","cmc":"0,07 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 °C"}],"reference_zh":"内部程序 PT 402","regulatory_area_zh":"量值的电模拟","search_zh":"温度指示仪（表）（包括温度控制器） 温度记录仪 校准 — 物理量的电模拟 内部程序；电学法校准；在固定地点 (S) 量值的电模拟 内部程序 电学法校准 在固定地点 (S) 内部程序 PT 402","technique_zh":"内部程序；电学法校准；在固定地点 (S)","techniques_zh":["内部程序","电学法校准","在固定地点 (S)"],"test_object_zh":"温度指示仪（表）（包括温度控制器）\n温度记录仪","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,07 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 °C"}],"reference_cs":"Vnitřní postup PT 402","regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Ukazatele (měřidla) teploty (včetně regulátorů teploty) Záznamníky teploty Kalibrace — Elektrická simulace veličin Vnitřní postup; Kalibrace elektrickou metodou; Ve stálé lokalitě (S) Elektrická simulace veličin Vnitřní postup Kalibrace elektrickou metodou Ve stálé lokalitě (S) Vnitřní postup PT 402","technique_cs":"Vnitřní postup; Kalibrace elektrickou metodou; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Kalibrace elektrickou metodou","Ve stálé lokalitě (S)"],"test_object_cs":"Ukazatele (měřidla) teploty (včetně regulátorů teploty)\nZáznamníky teploty"},{"_id":"74c2f21096ef103139d66b66","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Wskaźniki (mierniki) temperatury (w tym regulatory temperatury)\nRejestratory temperatury","test_object_en":"Temperature indicators (meters) (including temperature controllers)\nTemperature recorders","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electrical simulation of quantities","parameters":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,36 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,98 °C"}],"parameters_en":[{"name":"","range":"-200 °C to 850 °C","cmc":"0,36 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,98 °C"}],"technique":"Procedura wewnętrzna; Wzorcowanie metodą elektryczną; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Calibration by the electrical method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Wzorcowanie metodą elektryczną","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Calibration by the electrical method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-200 °C do 850 °C CMC 0,36 °C\n-200 °C do 1820 °C CMC 0,98 °C\nProcedura wewnętrzna; Wzorcowanie metodą elektryczną; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 402","norm_bases":["PT 402"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electrical simulation of quantities","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Wskaźniki (mierniki) temperatury (w tym regulatory temperatury)\nRejestratory temperatury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-200 °C do 850 °C CMC 0,36 °C\n-200 °C do 1820 °C CMC 0,98 °C\nProcedura wewnętrzna; Wzorcowanie metodą elektryczną; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 402 Wskazniki (mierniki) temperatury (w tym regulatory temperatury)\nRejestratory temperatury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\n-200 °C do 850 °C CMC 0,36 °C\n-200 °C do 1820 °C CMC 0,98 °C\nProcedura wewnetrzna; Wzorcowanie metoda elektryczna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 402","search_en":"Temperature indicators (meters) (including temperature controllers) Temperature recorders Calibration — Electrical simulation of quantities Internal procedure; Calibration by the electrical method; Outside of permanent location (P) Electrical simulation of quantities Internal procedure Calibration by the electrical method Outside of permanent location (P) Internal procedure PT 402","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":33,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 402","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-200 °C bis 850 °C","cmc":"0,36 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,98 °C"}],"reference_de":"Internes Verfahren PT 402","regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturanzeiger (-messgeräte) (einschließlich Temperaturregler) Temperaturschreiber Kalibrierung — Elektrische Simulation von Größen Internes Verfahren; Kalibrierung mit dem elektrischen Verfahren; Außerhalb des festen Standorts (P) Elektrische Simulation von Größen Internes Verfahren Kalibrierung mit dem elektrischen Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 402","technique_de":"Internes Verfahren; Kalibrierung mit dem elektrischen Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Kalibrierung mit dem elektrischen Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Temperaturanzeiger (-messgeräte) (einschließlich Temperaturregler)\nTemperaturschreiber","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-200 °C 至 850 °C","cmc":"0,36 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,98 °C"}],"reference_zh":"内部程序 PT 402","regulatory_area_zh":"量值的电模拟","search_zh":"温度指示仪（表）（包括温度控制器） 温度记录仪 校准 — 物理量的电模拟 内部程序；电学法校准；固定地点以外 (P) 量值的电模拟 内部程序 电学法校准 固定地点以外 (P) 内部程序 PT 402","technique_zh":"内部程序；电学法校准；固定地点以外 (P)","techniques_zh":["内部程序","电学法校准","固定地点以外 (P)"],"test_object_zh":"温度指示仪（表）（包括温度控制器）\n温度记录仪","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,36 °C"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,98 °C"}],"reference_cs":"Vnitřní postup PT 402","regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Ukazatele (měřidla) teploty (včetně regulátorů teploty) Záznamníky teploty Kalibrace — Elektrická simulace veličin Vnitřní postup; Kalibrace elektrickou metodou; Mimo stálou lokalitu (P) Elektrická simulace veličin Vnitřní postup Kalibrace elektrickou metodou Mimo stálou lokalitu (P) Vnitřní postup PT 402","technique_cs":"Vnitřní postup; Kalibrace elektrickou metodou; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Kalibrace elektrickou metodou","Mimo stálou lokalitu (P)"],"test_object_cs":"Ukazatele (měřidla) teploty (včetně regulátorů teploty)\nZáznamníky teploty"},{"_id":"f48dc4867bbdc5b49edae53b","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Symulatory temperatury","test_object_en":"Temperature simulators","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electrical simulation of quantities","parameters":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,07 oC"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 oC"}],"parameters_en":[{"name":"","range":"-200 °C to 850 °C","cmc":"0,07 oC"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 oC"}],"technique":"Procedura wewnętrzna; Wzorcowanie metodą elektryczną; W stałej lokalizacji (S)","technique_en":"Internal procedure; Calibration by the electrical method; At permanent location (S)","techniques":["Procedura wewnętrzna","Wzorcowanie metodą elektryczną","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Calibration by the electrical method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-200 °C do 850 °C CMC 0,07 oC\n-200 °C do 1820 °C CMC 0,24 oC\nProcedura wewnętrzna; Wzorcowanie metodą elektryczną; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 403","norm_bases":["PT 403"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electrical simulation of quantities","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Symulatory temperatury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-200 °C do 850 °C CMC 0,07 oC\n-200 °C do 1820 °C CMC 0,24 oC\nProcedura wewnętrzna; Wzorcowanie metodą elektryczną; W stałej lokalizacji (S) Procedura wewnętrzna PT 403 Symulatory temperatury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\n-200 °C do 850 °C CMC 0,07 oC\n-200 °C do 1820 °C CMC 0,24 oC\nProcedura wewnetrzna; Wzorcowanie metoda elektryczna; W stalej lokalizacji (S) Procedura wewnetrzna PT 403","search_en":"Temperature simulators Calibration — Electrical simulation of quantities Internal procedure; Calibration by the electrical method; At permanent location (S) Electrical simulation of quantities Internal procedure Calibration by the electrical method At permanent location (S) Internal procedure PT 403","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":34,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 403","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-200 °C bis 850 °C","cmc":"0,07 oC"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 oC"}],"reference_de":"Internes Verfahren PT 403","regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperatursimulatoren Kalibrierung — Elektrische Simulation von Größen Internes Verfahren; Kalibrierung mit dem elektrischen Verfahren; Am festen Standort (S) Elektrische Simulation von Größen Internes Verfahren Kalibrierung mit dem elektrischen Verfahren Am festen Standort (S) Internes Verfahren PT 403","technique_de":"Internes Verfahren; Kalibrierung mit dem elektrischen Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Kalibrierung mit dem elektrischen Verfahren","Am festen Standort (S)"],"test_object_de":"Temperatursimulatoren","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-200 °C 至 850 °C","cmc":"0,07 oC"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 oC"}],"reference_zh":"内部程序 PT 403","regulatory_area_zh":"量值的电模拟","search_zh":"温度模拟器 校准 — 物理量的电模拟 内部程序；电学法校准；在固定地点 (S) 量值的电模拟 内部程序 电学法校准 在固定地点 (S) 内部程序 PT 403","technique_zh":"内部程序；电学法校准；在固定地点 (S)","techniques_zh":["内部程序","电学法校准","在固定地点 (S)"],"test_object_zh":"温度模拟器","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,07 oC"},{"name":"","range":"-200 °C do 1820 °C","cmc":"0,24 oC"}],"reference_cs":"Vnitřní postup PT 403","regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Simulátory teploty Kalibrace — Elektrická simulace veličin Vnitřní postup; Kalibrace elektrickou metodou; Ve stálé lokalitě (S) Elektrická simulace veličin Vnitřní postup Kalibrace elektrickou metodou Ve stálé lokalitě (S) Vnitřní postup PT 403","technique_cs":"Vnitřní postup; Kalibrace elektrickou metodou; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Kalibrace elektrickou metodou","Ve stálé lokalitě (S)"],"test_object_cs":"Simulátory teploty"},{"_id":"32a129ed9e5e32e2672bf9c1","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Symulatory temperatury","test_object_en":"Temperature simulators","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electrical simulation of quantities","parameters":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,36 oC"},{"name":"","range":"-200 °C do do 1820 °C","cmc":"0,98 oC"}],"parameters_en":[{"name":"","range":"-200 °C to 850 °C","cmc":"0,36 oC"},{"name":"","range":"-200 °C do do 1820 °C","cmc":"0,98 oC"}],"technique":"Procedura wewnętrzna; Wzorcowanie metodą elektryczną; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Calibration by the electrical method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Wzorcowanie metodą elektryczną","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Calibration by the electrical method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-200 °C do 850 °C CMC 0,36 oC\n-200 °C do do 1820 °C CMC 0,98 oC\nProcedura wewnętrzna; Wzorcowanie metodą elektryczną; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 403","norm_bases":["PT 403"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electrical simulation of quantities","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Symulatory temperatury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-200 °C do 850 °C CMC 0,36 oC\n-200 °C do do 1820 °C CMC 0,98 oC\nProcedura wewnętrzna; Wzorcowanie metodą elektryczną; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 403 Symulatory temperatury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\n-200 °C do 850 °C CMC 0,36 oC\n-200 °C do do 1820 °C CMC 0,98 oC\nProcedura wewnetrzna; Wzorcowanie metoda elektryczna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 403","search_en":"Temperature simulators Calibration — Electrical simulation of quantities Internal procedure; Calibration by the electrical method; Outside of permanent location (P) Electrical simulation of quantities Internal procedure Calibration by the electrical method Outside of permanent location (P) Internal procedure PT 403","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":35,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 403","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-200 °C bis 850 °C","cmc":"0,36 oC"},{"name":"","range":"-200 °C do do 1820 °C","cmc":"0,98 oC"}],"reference_de":"Internes Verfahren PT 403","regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperatursimulatoren Kalibrierung — Elektrische Simulation von Größen Internes Verfahren; Kalibrierung mit dem elektrischen Verfahren; Außerhalb des festen Standorts (P) Elektrische Simulation von Größen Internes Verfahren Kalibrierung mit dem elektrischen Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 403","technique_de":"Internes Verfahren; Kalibrierung mit dem elektrischen Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Kalibrierung mit dem elektrischen Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Temperatursimulatoren","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-200 °C 至 850 °C","cmc":"0,36 oC"},{"name":"","range":"-200 °C do do 1820 °C","cmc":"0,98 oC"}],"reference_zh":"内部程序 PT 403","regulatory_area_zh":"量值的电模拟","search_zh":"温度模拟器 校准 — 物理量的电模拟 内部程序；电学法校准；固定地点以外 (P) 量值的电模拟 内部程序 电学法校准 固定地点以外 (P) 内部程序 PT 403","technique_zh":"内部程序；电学法校准；固定地点以外 (P)","techniques_zh":["内部程序","电学法校准","固定地点以外 (P)"],"test_object_zh":"温度模拟器","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,36 oC"},{"name":"","range":"-200 °C do do 1820 °C","cmc":"0,98 oC"}],"reference_cs":"Vnitřní postup PT 403","regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Simulátory teploty Kalibrace — Elektrická simulace veličin Vnitřní postup; Kalibrace elektrickou metodou; Mimo stálou lokalitu (P) Elektrická simulace veličin Vnitřní postup Kalibrace elektrickou metodou Mimo stálou lokalitu (P) Vnitřní postup PT 403","technique_cs":"Vnitřní postup; Kalibrace elektrickou metodou; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Kalibrace elektrickou metodou","Mimo stálou lokalitu (P)"],"test_object_cs":"Simulátory teploty"},{"_id":"2c1a71b4a0028778a06ed3c2","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Przetworniki","test_object_en":"Transmitters","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"zakres temperatur 5 °C do 60 °C","range":"10 %rh do 90 %rh","cmc":"2,0 %rh"}],"parameters_en":[{"name":"zakres temperatur 5 °C to 60 °C","range":"10 %rh to 90 %rh","cmc":"2,0 %rh"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 2,0 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 501","norm_bases":["PT 501"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przetworniki Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 2,0 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 501 Przetworniki Wzorcowanie — Wilgotnosc wzgledna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 2,0 %rh\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 501","search_en":"Transmitters Calibration — Relative humidity Internal procedure; Direct method; At permanent location (S) Relative humidity Internal procedure Direct method At permanent location (S) zakres temperatur 5 °C to 60 °C Internal procedure PT 501","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":36,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 501","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"Temperaturbereich 5 °C bis 60 °C","range":"10 %rh to 90 %rh","cmc":"2,0 %rh"}],"reference_de":"Internes Verfahren PT 501","regulatory_area_de":"Relative Feuchte","search_de":"Messumformer Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Relative Feuchte Internes Verfahren Direktes Verfahren Am festen Standort (S) Temperaturbereich 5 °C bis 60 °C Internes Verfahren PT 501","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Messumformer","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围 5 °C 至 60 °C","range":"10 %rh to 90 %rh","cmc":"2,0 %rh"}],"reference_zh":"内部程序 PT 501","regulatory_area_zh":"相对湿度","search_zh":"变送器 校准 — 相对湿度 内部程序；直接法；在固定地点 (S) 相对湿度 内部程序 直接法 在固定地点 (S) 温度范围 5 °C 至 60 °C 内部程序 PT 501","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"变送器","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"rozsah teplot 5 °C až 60 °C","range":"10 %rh to 90 %rh","cmc":"2,0 %rh"}],"reference_cs":"Vnitřní postup PT 501","regulatory_area_cs":"Relativní vlhkost","search_cs":"Snímače Kalibrace — Relativní vlhkost Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Relativní vlhkost Vnitřní postup Přímá metoda Ve stálé lokalitě (S) rozsah teplot 5 °C až 60 °C Vnitřní postup PT 501","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Snímače"},{"_id":"fb650a001a77a631cb3f1daa","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Przetworniki","test_object_en":"Transmitters","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"zakres temperatur 5 °C do 60 °C","range":"10 %rh do 90 %rh","cmc":"3,0 %rh"}],"parameters_en":[{"name":"zakres temperatur 5 °C to 60 °C","range":"10 %rh to 90 %rh","cmc":"3,0 %rh"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 3,0 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 501","norm_bases":["PT 501"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Przetworniki Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 3,0 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 501 Przetworniki Wzorcowanie — Wilgotnosc wzgledna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 3,0 %rh\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 501","search_en":"Transmitters Calibration — Relative humidity Internal procedure; Direct method; Outside of permanent location (P) Relative humidity Internal procedure Direct method Outside of permanent location (P) zakres temperatur 5 °C to 60 °C Internal procedure PT 501","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":37,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 501","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"Temperaturbereich 5 °C bis 60 °C","range":"10 %rh to 90 %rh","cmc":"3,0 %rh"}],"reference_de":"Internes Verfahren PT 501","regulatory_area_de":"Relative Feuchte","search_de":"Messumformer Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Relative Feuchte Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) Temperaturbereich 5 °C bis 60 °C Internes Verfahren PT 501","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Messumformer","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围 5 °C 至 60 °C","range":"10 %rh to 90 %rh","cmc":"3,0 %rh"}],"reference_zh":"内部程序 PT 501","regulatory_area_zh":"相对湿度","search_zh":"变送器 校准 — 相对湿度 内部程序；直接法；固定地点以外 (P) 相对湿度 内部程序 直接法 固定地点以外 (P) 温度范围 5 °C 至 60 °C 内部程序 PT 501","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"变送器","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"rozsah teplot 5 °C až 60 °C","range":"10 %rh to 90 %rh","cmc":"3,0 %rh"}],"reference_cs":"Vnitřní postup PT 501","regulatory_area_cs":"Relativní vlhkost","search_cs":"Snímače Kalibrace — Relativní vlhkost Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Relativní vlhkost Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) rozsah teplot 5 °C až 60 °C Vnitřní postup PT 501","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Snímače"},{"_id":"4667c83af5de6c77de748bf0","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Higrometry\nTermohigrometry\nTermohigrobarometry","test_object_en":"Hygrometers\nThermohygrometers\nThermohygrobarometers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"zakres temperatur 5 °C do 60 °C","range":"10 %rh do 90 %rh","cmc":"1,7 %rh"}],"parameters_en":[{"name":"zakres temperatur 5 °C to 60 °C","range":"10 %rh to 90 %rh","cmc":"1,7 %rh"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 1,7 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 502","norm_bases":["PT 502"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Higrometry\nTermohigrometry\nTermohigrobarometry Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 1,7 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 502 Higrometry\nTermohigrometry\nTermohigrobarometry Wzorcowanie — Wilgotnosc wzgledna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 1,7 %rh\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 502","search_en":"Hygrometers Thermohygrometers Thermohygrobarometers Calibration — Relative humidity Internal procedure; Direct method; At permanent location (S) Relative humidity Internal procedure Direct method At permanent location (S) zakres temperatur 5 °C to 60 °C Internal procedure PT 502","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":38,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 502","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"Temperaturbereich 5 °C bis 60 °C","range":"10 %rh to 90 %rh","cmc":"1,7 %rh"}],"reference_de":"Internes Verfahren PT 502","regulatory_area_de":"Relative Feuchte","search_de":"Hygrometer Thermohygrometer Thermohygrobarometer Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Relative Feuchte Internes Verfahren Direktes Verfahren Am festen Standort (S) Temperaturbereich 5 °C bis 60 °C Internes Verfahren PT 502","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Hygrometer\nThermohygrometer\nThermohygrobarometer","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围 5 °C 至 60 °C","range":"10 %rh to 90 %rh","cmc":"1,7 %rh"}],"reference_zh":"内部程序 PT 502","regulatory_area_zh":"相对湿度","search_zh":"湿度计 温湿度计 温湿度气压计 校准 — 相对湿度 内部程序；直接法；在固定地点 (S) 相对湿度 内部程序 直接法 在固定地点 (S) 温度范围 5 °C 至 60 °C 内部程序 PT 502","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"湿度计\n温湿度计\n温湿度气压计","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"rozsah teplot 5 °C až 60 °C","range":"10 %rh to 90 %rh","cmc":"1,7 %rh"}],"reference_cs":"Vnitřní postup PT 502","regulatory_area_cs":"Relativní vlhkost","search_cs":"Vlhkoměry Termohygrometry Termohygrobarometry Kalibrace — Relativní vlhkost Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Relativní vlhkost Vnitřní postup Přímá metoda Ve stálé lokalitě (S) rozsah teplot 5 °C až 60 °C Vnitřní postup PT 502","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Vlhkoměry\nTermohygrometry\nTermohygrobarometry"},{"_id":"24c5aca93c346bd43d9efbb1","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Higrometry\nTermohigrometry\nTermohigrobarometry","test_object_en":"Hygrometers\nThermohygrometers\nThermohygrobarometers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"zakres temperatur 5 °C do 60 °C","range":"10 %rh do 90 %rh","cmc":"3,0 %rh"}],"parameters_en":[{"name":"zakres temperatur 5 °C to 60 °C","range":"10 %rh to 90 %rh","cmc":"3,0 %rh"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 3,0 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 502","norm_bases":["PT 502"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Higrometry\nTermohigrometry\nTermohigrobarometry Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 3,0 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 502 Higrometry\nTermohigrometry\nTermohigrobarometry Wzorcowanie — Wilgotnosc wzgledna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 3,0 %rh\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 502","search_en":"Hygrometers Thermohygrometers Thermohygrobarometers Calibration — Relative humidity Internal procedure; Direct method; Outside of permanent location (P) Relative humidity Internal procedure Direct method Outside of permanent location (P) zakres temperatur 5 °C to 60 °C Internal procedure PT 502","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":39,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 502","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"Temperaturbereich 5 °C bis 60 °C","range":"10 %rh to 90 %rh","cmc":"3,0 %rh"}],"reference_de":"Internes Verfahren PT 502","regulatory_area_de":"Relative Feuchte","search_de":"Hygrometer Thermohygrometer Thermohygrobarometer Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Relative Feuchte Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) Temperaturbereich 5 °C bis 60 °C Internes Verfahren PT 502","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Hygrometer\nThermohygrometer\nThermohygrobarometer","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围 5 °C 至 60 °C","range":"10 %rh to 90 %rh","cmc":"3,0 %rh"}],"reference_zh":"内部程序 PT 502","regulatory_area_zh":"相对湿度","search_zh":"湿度计 温湿度计 温湿度气压计 校准 — 相对湿度 内部程序；直接法；固定地点以外 (P) 相对湿度 内部程序 直接法 固定地点以外 (P) 温度范围 5 °C 至 60 °C 内部程序 PT 502","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"湿度计\n温湿度计\n温湿度气压计","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"rozsah teplot 5 °C až 60 °C","range":"10 %rh to 90 %rh","cmc":"3,0 %rh"}],"reference_cs":"Vnitřní postup PT 502","regulatory_area_cs":"Relativní vlhkost","search_cs":"Vlhkoměry Termohygrometry Termohygrobarometry Kalibrace — Relativní vlhkost Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Relativní vlhkost Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) rozsah teplot 5 °C až 60 °C Vnitřní postup PT 502","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Vlhkoměry\nTermohygrometry\nTermohygrobarometry"},{"_id":"d13024d994d28c3615e445b7","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Komory klimatyczne","test_object_en":"Climatic chambers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"zakres temperatur 5 °C do 60 °C","range":"10 % do 90 %rh","cmc":"2,5 %rh"}],"parameters_en":[{"name":"zakres temperatur 5 °C to 60 °C","range":"10 % to 90 %rh","cmc":"2,5 %rh"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 60 °C 10 % do 90 %rh CMC 2,5 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 503 w oparciu o EURAMET cg-20 v. 5.0","norm_bases":["PT 503","EURAMET cg-20 v. 5.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":false,"location_of_activity":"S","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Komory klimatyczne Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 60 °C 10 % do 90 %rh CMC 2,5 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 503 w oparciu o EURAMET cg-20 v. 5.0 Komory klimatyczne Wzorcowanie — Wilgotnosc wzgledna\nzakres temperatur 5 °C do 60 °C 10 % do 90 %rh CMC 2,5 %rh\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 503 w oparciu o EURAMET cg-20 v. 5.0","search_en":"Climatic chambers Calibration — Relative humidity Internal procedure; Direct method; At permanent location (S) Relative humidity Internal procedure Direct method At permanent location (S) zakres temperatur 5 °C to 60 °C Internal procedure PT 503 based on EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":40,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 503 based on EURAMET cg-20 v. 5.0","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"Temperaturbereich 5 °C bis 60 °C","range":"10 % to 90 %rh","cmc":"2,5 %rh"}],"reference_de":"Internes Verfahren PT 503 auf Grundlage von EURAMET cg-20 v. 5.0","regulatory_area_de":"Relative Feuchte","search_de":"Klimakammern Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Relative Feuchte Internes Verfahren Direktes Verfahren Am festen Standort (S) Temperaturbereich 5 °C bis 60 °C Internes Verfahren PT 503 auf Grundlage von EURAMET cg-20 v. 5.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Klimakammern","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围 5 °C 至 60 °C","range":"10 % to 90 %rh","cmc":"2,5 %rh"}],"reference_zh":"内部程序 PT 503 依据EURAMET cg-20 v. 5.0","regulatory_area_zh":"相对湿度","search_zh":"气候箱 校准 — 相对湿度 内部程序；直接法；在固定地点 (S) 相对湿度 内部程序 直接法 在固定地点 (S) 温度范围 5 °C 至 60 °C 内部程序 PT 503 依据EURAMET cg-20 v. 5.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"气候箱","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"rozsah teplot 5 °C až 60 °C","range":"10 % to 90 %rh","cmc":"2,5 %rh"}],"reference_cs":"Vnitřní postup PT 503 na základě EURAMET cg-20 v. 5.0","regulatory_area_cs":"Relativní vlhkost","search_cs":"Klimatické komory Kalibrace — Relativní vlhkost Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Relativní vlhkost Vnitřní postup Přímá metoda Ve stálé lokalitě (S) rozsah teplot 5 °C až 60 °C Vnitřní postup PT 503 na základě EURAMET cg-20 v. 5.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Klimatické komory"},{"_id":"97aff9bd1f5bce827f841ebe","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Komory klimatyczne","test_object_en":"Climatic chambers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"zakres temperatur 5 °C do 60 °C","range":"10 %rh do 90 %rh","cmc":"3,0 %rh"}],"parameters_en":[{"name":"zakres temperatur 5 °C to 60 °C","range":"10 %rh to 90 %rh","cmc":"3,0 %rh"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 3,0 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 503 w oparciu o EURAMET cg-20 v. 5.0","norm_bases":["PT 503","EURAMET cg-20 v. 5.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":true,"location_of_activity":"P","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Komory klimatyczne Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 3,0 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 503 w oparciu o EURAMET cg-20 v. 5.0 Komory klimatyczne Wzorcowanie — Wilgotnosc wzgledna\nzakres temperatur 5 °C do 60 °C 10 %rh do 90 %rh CMC 3,0 %rh\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 503 w oparciu o EURAMET cg-20 v. 5.0","search_en":"Climatic chambers Calibration — Relative humidity Internal procedure; Direct method; Outside of permanent location (P) Relative humidity Internal procedure Direct method Outside of permanent location (P) zakres temperatur 5 °C to 60 °C Internal procedure PT 503 based on EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":41,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 503 based on EURAMET cg-20 v. 5.0","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"Temperaturbereich 5 °C bis 60 °C","range":"10 %rh to 90 %rh","cmc":"3,0 %rh"}],"reference_de":"Internes Verfahren PT 503 auf Grundlage von EURAMET cg-20 v. 5.0","regulatory_area_de":"Relative Feuchte","search_de":"Klimakammern Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Relative Feuchte Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) Temperaturbereich 5 °C bis 60 °C Internes Verfahren PT 503 auf Grundlage von EURAMET cg-20 v. 5.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Klimakammern","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围 5 °C 至 60 °C","range":"10 %rh to 90 %rh","cmc":"3,0 %rh"}],"reference_zh":"内部程序 PT 503 依据EURAMET cg-20 v. 5.0","regulatory_area_zh":"相对湿度","search_zh":"气候箱 校准 — 相对湿度 内部程序；直接法；固定地点以外 (P) 相对湿度 内部程序 直接法 固定地点以外 (P) 温度范围 5 °C 至 60 °C 内部程序 PT 503 依据EURAMET cg-20 v. 5.0","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"气候箱","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"rozsah teplot 5 °C až 60 °C","range":"10 %rh to 90 %rh","cmc":"3,0 %rh"}],"reference_cs":"Vnitřní postup PT 503 na základě EURAMET cg-20 v. 5.0","regulatory_area_cs":"Relativní vlhkost","search_cs":"Klimatické komory Kalibrace — Relativní vlhkost Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Relativní vlhkost Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) rozsah teplot 5 °C až 60 °C Vnitřní postup PT 503 na základě EURAMET cg-20 v. 5.0","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Klimatické komory"},{"_id":"46bf5637c1f2a83f8c94c2d5","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\nPressure transmitters","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"-0,1 MPa do -0,03 MPa","cmc":"3,0·10⁻⁵ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"-0,03 MPa do -0,0024 MPa","cmc":"1,1·10⁻⁵ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"-0,0024 MPa do 0,0024 MPa","cmc":"2,0·10⁻⁶ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"0,0024 MPa do 0,01 MPa","cmc":"6,2·10⁻⁶ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"0,01 MPa do 0,03 MPa","cmc":"1,1·10⁻⁵ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"0,03 MPa do 0,2 MPa","cmc":"4,4·10⁻⁵ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"0,2 MPa do 1,8 MPa","cmc":"6·10⁻⁶ P + 0,0002 MPa"}],"parameters_en":[{"name":"- gauge pressure, negative and positive pressure (gas)","range":"-0,1 MPa to -0,03 MPa","cmc":"3,0·10⁻⁵ MPa"},{"name":"- gauge pressure, negative and positive pressure (gas)","range":"-0,03 MPa to -0,0024 MPa","cmc":"1,1·10⁻⁵ MPa"},{"name":"- gauge pressure, negative and positive pressure (gas)","range":"-0,0024 MPa to 0,0024 MPa","cmc":"2,0·10⁻⁶ MPa"},{"name":"- gauge pressure, negative and positive pressure (gas)","range":"0,0024 MPa to 0,01 MPa","cmc":"6,2·10⁻⁶ MPa"},{"name":"- gauge pressure, negative and positive pressure (gas)","range":"0,01 MPa to 0,03 MPa","cmc":"1,1·10⁻⁵ MPa"},{"name":"- gauge pressure, negative and positive pressure (gas)","range":"0,03 MPa to 0,2 MPa","cmc":"4,4·10⁻⁵ MPa"},{"name":"- gauge pressure, negative and positive pressure (gas)","range":"0,2 MPa to 1,8 MPa","cmc":"6·10⁻⁶ P + 0,0002 MPa"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) -0,1 MPa do -0,03 MPa CMC 3,0·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) -0,03 MPa do -0,0024 MPa CMC 1,1·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) -0,0024 MPa do 0,0024 MPa CMC 2,0·10⁻⁶ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,0024 MPa do 0,01 MPa CMC 6,2·10⁻⁶ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,01 MPa do 0,03 MPa CMC 1,1·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,03 MPa do 0,2 MPa CMC 4,4·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,2 MPa do 1,8 MPa CMC 6·10⁻⁶ P + 0,0002 MPa\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0","norm_bases":["PT 301","PT 302","EURAMET cg-17 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":"P - wielkość mierzona (MPa)","note_en":"P - measured quantity (MPa)","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) -0,1 MPa do -0,03 MPa CMC 3,0·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) -0,03 MPa do -0,0024 MPa CMC 1,1·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) -0,0024 MPa do 0,0024 MPa CMC 2,0·10⁻⁶ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,0024 MPa do 0,01 MPa CMC 6,2·10⁻⁶ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,01 MPa do 0,03 MPa CMC 1,1·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,03 MPa do 0,2 MPa CMC 4,4·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,2 MPa do 1,8 MPa CMC 6·10⁻⁶ P + 0,0002 MPa\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0 Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\nPrzetworniki cisnienia Wzorcowanie — Cisnienie\nZakres:\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) -0,1 MPa do -0,03 MPa CMC 3,0·10⁻⁵ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) -0,03 MPa do -0,0024 MPa CMC 1,1·10⁻⁵ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) -0,0024 MPa do 0,0024 MPa CMC 2,0·10⁻⁶ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) 0,0024 MPa do 0,01 MPa CMC 6,2·10⁻⁶ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) 0,01 MPa do 0,03 MPa CMC 1,1·10⁻⁵ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) 0,03 MPa do 0,2 MPa CMC 4,4·10⁻⁵ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) 0,2 MPa do 1,8 MPa CMC 6·10⁻⁶ P + 0,0002 MPa\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0","search_en":"Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters Calibration — Pressure Internal procedure; At permanent location (S) Pressure Internal procedure At permanent location (S) - gauge pressure, negative and positive pressure (gas) - gauge pressure, negative and positive pressure (gas) - gauge pressure, negative and positive pressure (gas) - gauge pressure, negative and positive pressure (gas) - gauge pressure, negative and positive pressure (gas) - gauge pressure, negative and positive pressure (gas) - gauge pressure, negative and positive pressure (gas) Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":42,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"-0,1 MPa to -0,03 MPa","cmc":"3,0·10⁻⁵ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"-0,03 MPa to -0,0024 MPa","cmc":"1,1·10⁻⁵ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"-0,0024 MPa to 0,0024 MPa","cmc":"2,0·10⁻⁶ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"0,0024 MPa to 0,01 MPa","cmc":"6,2·10⁻⁶ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"0,01 MPa to 0,03 MPa","cmc":"1,1·10⁻⁵ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"0,03 MPa to 0,2 MPa","cmc":"4,4·10⁻⁵ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"0,2 MPa to 1,8 MPa","cmc":"6·10⁻⁶ P + 0,0002 MPa"}],"reference_de":"Internes Verfahren PT 301, PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte Druckmessumformer Kalibrierung — Druck Internes Verfahren; Am festen Standort (S) Druck Internes Verfahren Am festen Standort (S) - Relativdruck, Unter- und Überdruck (Gas) - Relativdruck, Unter- und Überdruck (Gas) - Relativdruck, Unter- und Überdruck (Gas) - Relativdruck, Unter- und Überdruck (Gas) - Relativdruck, Unter- und Überdruck (Gas) - Relativdruck, Unter- und Überdruck (Gas) - Relativdruck, Unter- und Überdruck (Gas) Internes Verfahren PT 301, PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\nDruckmessumformer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 表压，负压和正压（气体）","range":"-0,1 MPa to -0,03 MPa","cmc":"3,0·10⁻⁵ MPa"},{"name":"- 表压，负压和正压（气体）","range":"-0,03 MPa to -0,0024 MPa","cmc":"1,1·10⁻⁵ MPa"},{"name":"- 表压，负压和正压（气体）","range":"-0,0024 MPa to 0,0024 MPa","cmc":"2,0·10⁻⁶ MPa"},{"name":"- 表压，负压和正压（气体）","range":"0,0024 MPa to 0,01 MPa","cmc":"6,2·10⁻⁶ MPa"},{"name":"- 表压，负压和正压（气体）","range":"0,01 MPa to 0,03 MPa","cmc":"1,1·10⁻⁵ MPa"},{"name":"- 表压，负压和正压（气体）","range":"0,03 MPa to 0,2 MPa","cmc":"4,4·10⁻⁵ MPa"},{"name":"- 表压，负压和正压（气体）","range":"0,2 MPa to 1,8 MPa","cmc":"6·10⁻⁶ P + 0,0002 MPa"}],"reference_zh":"内部程序 PT 301, PT 302 依据EURAMET cg-17 v. 4.0","regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 压力变送器 校准 — 压力 内部程序；在固定地点 (S) 压力 内部程序 在固定地点 (S) - 表压，负压和正压（气体） - 表压，负压和正压（气体） - 表压，负压和正压（气体） - 表压，负压和正压（气体） - 表压，负压和正压（气体） - 表压，负压和正压（气体） - 表压，负压和正压（气体） 内部程序 PT 301, PT 302 依据EURAMET cg-17 v. 4.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"弹簧管压力表\n电子压力计\n压力变送器","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- přetlak, podtlak a přetlak (plyn)","range":"-0,1 MPa to -0,03 MPa","cmc":"3,0·10⁻⁵ MPa"},{"name":"- přetlak, podtlak a přetlak (plyn)","range":"-0,03 MPa to -0,0024 MPa","cmc":"1,1·10⁻⁵ MPa"},{"name":"- přetlak, podtlak a přetlak (plyn)","range":"-0,0024 MPa to 0,0024 MPa","cmc":"2,0·10⁻⁶ MPa"},{"name":"- přetlak, podtlak a přetlak (plyn)","range":"0,0024 MPa to 0,01 MPa","cmc":"6,2·10⁻⁶ MPa"},{"name":"- přetlak, podtlak a přetlak (plyn)","range":"0,01 MPa to 0,03 MPa","cmc":"1,1·10⁻⁵ MPa"},{"name":"- přetlak, podtlak a přetlak (plyn)","range":"0,03 MPa to 0,2 MPa","cmc":"4,4·10⁻⁵ MPa"},{"name":"- přetlak, podtlak a přetlak (plyn)","range":"0,2 MPa to 1,8 MPa","cmc":"6·10⁻⁶ P + 0,0002 MPa"}],"reference_cs":"Vnitřní postup PT 301, PT 302 na základě EURAMET cg-17 v. 4.0","regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry Převodníky tlaku Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) Tlak Vnitřní postup Ve stálé lokalitě (S) - přetlak, podtlak a přetlak (plyn) - přetlak, podtlak a přetlak (plyn) - přetlak, podtlak a přetlak (plyn) - přetlak, podtlak a přetlak (plyn) - přetlak, podtlak a přetlak (plyn) - přetlak, podtlak a přetlak (plyn) - přetlak, podtlak a přetlak (plyn) Vnitřní postup PT 301, PT 302 na základě EURAMET cg-17 v. 4.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\nPřevodníky tlaku"},{"_id":"50fb2f1c4cc5b438f6c72a06","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\nPressure transmitters","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"-0,1 MPa do -0,005 MPa","cmc":"1,2·10⁻⁴ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"-0,005 MPa do 0 MPa","cmc":"5,5·10⁻⁵ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"0 MPa do 0,002 MPa","cmc":"0,6·10⁻⁵ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"0,002 MPa do 0,005 MPa","cmc":"5,5·10⁻⁵ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"0,005 MPa do 0,3 MPa","cmc":"1,2·10⁻⁴ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (gaz)","range":"0,3 MPa do 1,0 MPa","cmc":"1,2·10⁻³ MPa"}],"parameters_en":[{"name":"- gauge pressure, negative and positive pressure (gas)","range":"-0,1 MPa to -0,005 MPa","cmc":"1,2·10⁻⁴ MPa"},{"name":"- gauge pressure, negative and positive pressure (gas)","range":"-0,005 MPa to 0 MPa","cmc":"5,5·10⁻⁵ MPa"},{"name":"- gauge pressure, negative and positive pressure (gas)","range":"0 MPa to 0,002 MPa","cmc":"0,6·10⁻⁵ MPa"},{"name":"- gauge pressure, negative and positive pressure (gas)","range":"0,002 MPa to 0,005 MPa","cmc":"5,5·10⁻⁵ MPa"},{"name":"- gauge pressure, negative and positive pressure (gas)","range":"0,005 MPa to 0,3 MPa","cmc":"1,2·10⁻⁴ MPa"},{"name":"- gauge pressure, negative and positive pressure (gas)","range":"0,3 MPa to 1,0 MPa","cmc":"1,2·10⁻³ MPa"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) -0,1 MPa do -0,005 MPa CMC 1,2·10⁻⁴ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) -0,005 MPa do 0 MPa CMC 5,5·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0 MPa do 0,002 MPa CMC 0,6·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,002 MPa do 0,005 MPa CMC 5,5·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,005 MPa do 0,3 MPa CMC 1,2·10⁻⁴ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,3 MPa do 1,0 MPa CMC 1,2·10⁻³ MPa\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0","norm_bases":["PT 301","PT 302","EURAMET cg-17 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"P","note":"P - wielkość mierzona (MPa)","note_en":"P - measured quantity (MPa)","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) -0,1 MPa do -0,005 MPa CMC 1,2·10⁻⁴ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) -0,005 MPa do 0 MPa CMC 5,5·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0 MPa do 0,002 MPa CMC 0,6·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,002 MPa do 0,005 MPa CMC 5,5·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,005 MPa do 0,3 MPa CMC 1,2·10⁻⁴ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (gaz) 0,3 MPa do 1,0 MPa CMC 1,2·10⁻³ MPa\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0 Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\nPrzetworniki cisnienia Wzorcowanie — Cisnienie\nZakres:\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) -0,1 MPa do -0,005 MPa CMC 1,2·10⁻⁴ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) -0,005 MPa do 0 MPa CMC 5,5·10⁻⁵ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) 0 MPa do 0,002 MPa CMC 0,6·10⁻⁵ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) 0,002 MPa do 0,005 MPa CMC 5,5·10⁻⁵ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) 0,005 MPa do 0,3 MPa CMC 1,2·10⁻⁴ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (gaz) 0,3 MPa do 1,0 MPa CMC 1,2·10⁻³ MPa\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0","search_en":"Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters Calibration — Pressure Internal procedure; Outside of permanent location (P) Pressure Internal procedure Outside of permanent location (P) - gauge pressure, negative and positive pressure (gas) - gauge pressure, negative and positive pressure (gas) - gauge pressure, negative and positive pressure (gas) - gauge pressure, negative and positive pressure (gas) - gauge pressure, negative and positive pressure (gas) - gauge pressure, negative and positive pressure (gas) Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":43,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"-0,1 MPa to -0,005 MPa","cmc":"1,2·10⁻⁴ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"-0,005 MPa to 0 MPa","cmc":"5,5·10⁻⁵ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"0 MPa to 0,002 MPa","cmc":"0,6·10⁻⁵ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"0,002 MPa to 0,005 MPa","cmc":"5,5·10⁻⁵ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"0,005 MPa to 0,3 MPa","cmc":"1,2·10⁻⁴ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Gas)","range":"0,3 MPa to 1,0 MPa","cmc":"1,2·10⁻³ MPa"}],"reference_de":"Internes Verfahren PT 301, PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte Druckmessumformer Kalibrierung — Druck Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Druck Internes Verfahren Außerhalb des festen Standorts (P) - Relativdruck, Unter- und Überdruck (Gas) - Relativdruck, Unter- und Überdruck (Gas) - Relativdruck, Unter- und Überdruck (Gas) - Relativdruck, Unter- und Überdruck (Gas) - Relativdruck, Unter- und Überdruck (Gas) - Relativdruck, Unter- und Überdruck (Gas) Internes Verfahren PT 301, PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\nDruckmessumformer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 表压，负压和正压（气体）","range":"-0,1 MPa to -0,005 MPa","cmc":"1,2·10⁻⁴ MPa"},{"name":"- 表压，负压和正压（气体）","range":"-0,005 MPa to 0 MPa","cmc":"5,5·10⁻⁵ MPa"},{"name":"- 表压，负压和正压（气体）","range":"0 MPa to 0,002 MPa","cmc":"0,6·10⁻⁵ MPa"},{"name":"- 表压，负压和正压（气体）","range":"0,002 MPa to 0,005 MPa","cmc":"5,5·10⁻⁵ MPa"},{"name":"- 表压，负压和正压（气体）","range":"0,005 MPa to 0,3 MPa","cmc":"1,2·10⁻⁴ MPa"},{"name":"- 表压，负压和正压（气体）","range":"0,3 MPa to 1,0 MPa","cmc":"1,2·10⁻³ MPa"}],"reference_zh":"内部程序 PT 301, PT 302 依据EURAMET cg-17 v. 4.0","regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 压力变送器 校准 — 压力 内部程序；固定地点以外 (P) 压力 内部程序 固定地点以外 (P) - 表压，负压和正压（气体） - 表压，负压和正压（气体） - 表压，负压和正压（气体） - 表压，负压和正压（气体） - 表压，负压和正压（气体） - 表压，负压和正压（气体） 内部程序 PT 301, PT 302 依据EURAMET cg-17 v. 4.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"弹簧管压力表\n电子压力计\n压力变送器","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- přetlak, podtlak a přetlak (plyn)","range":"-0,1 MPa to -0,005 MPa","cmc":"1,2·10⁻⁴ MPa"},{"name":"- přetlak, podtlak a přetlak (plyn)","range":"-0,005 MPa to 0 MPa","cmc":"5,5·10⁻⁵ MPa"},{"name":"- přetlak, podtlak a přetlak (plyn)","range":"0 MPa to 0,002 MPa","cmc":"0,6·10⁻⁵ MPa"},{"name":"- přetlak, podtlak a přetlak (plyn)","range":"0,002 MPa to 0,005 MPa","cmc":"5,5·10⁻⁵ MPa"},{"name":"- přetlak, podtlak a přetlak (plyn)","range":"0,005 MPa to 0,3 MPa","cmc":"1,2·10⁻⁴ MPa"},{"name":"- přetlak, podtlak a přetlak (plyn)","range":"0,3 MPa to 1,0 MPa","cmc":"1,2·10⁻³ MPa"}],"reference_cs":"Vnitřní postup PT 301, PT 302 na základě EURAMET cg-17 v. 4.0","regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry Převodníky tlaku Kalibrace — Tlak Vnitřní postup; Mimo stálé pracoviště (P) Tlak Vnitřní postup Mimo stálou lokalitu (P) - přetlak, podtlak a přetlak (plyn) - přetlak, podtlak a přetlak (plyn) - přetlak, podtlak a přetlak (plyn) - přetlak, podtlak a přetlak (plyn) - přetlak, podtlak a přetlak (plyn) - přetlak, podtlak a přetlak (plyn) Vnitřní postup PT 301, PT 302 na základě EURAMET cg-17 v. 4.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\nPřevodníky tlaku"},{"_id":"c95733d69340d0b6c3d51536","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\nPressure transmitters","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (ciecz)","range":"0 MPa do 0,1 MPa","cmc":"3,4·10⁻⁵ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (ciecz)","range":"0,1 MPa do 0,6 MPa","cmc":"6,3·10⁻⁵ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (ciecz)","range":"0,6 MPa do 2,0 MPa","cmc":"6·10⁻⁶ · P + 0,0002 MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (ciecz)","range":"2,0 MPa do 70,0 MPa","cmc":"3·10⁻⁶ · P + 0,002 MPa"}],"parameters_en":[{"name":"- gauge pressure, negative and positive pressure (liquid)","range":"0 MPa to 0,1 MPa","cmc":"3,4·10⁻⁵ MPa"},{"name":"- gauge pressure, negative and positive pressure (liquid)","range":"0,1 MPa to 0,6 MPa","cmc":"6,3·10⁻⁵ MPa"},{"name":"- gauge pressure, negative and positive pressure (liquid)","range":"0,6 MPa to 2,0 MPa","cmc":"6·10⁻⁶ · P + 0,0002 MPa"},{"name":"- gauge pressure, negative and positive pressure (liquid)","range":"2,0 MPa to 70,0 MPa","cmc":"3·10⁻⁶ · P + 0,002 MPa"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 0 MPa do 0,1 MPa CMC 3,4·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 0,1 MPa do 0,6 MPa CMC 6,3·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 0,6 MPa do 2,0 MPa CMC 6·10⁻⁶ · P + 0,0002 MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 2,0 MPa do 70,0 MPa CMC 3·10⁻⁶ · P + 0,002 MPa\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0","norm_bases":["PT 301","PT 302","EURAMET cg-17 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":"P - wielkość mierzona (MPa)","note_en":"P - measured quantity (MPa)","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 0 MPa do 0,1 MPa CMC 3,4·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 0,1 MPa do 0,6 MPa CMC 6,3·10⁻⁵ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 0,6 MPa do 2,0 MPa CMC 6·10⁻⁶ · P + 0,0002 MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 2,0 MPa do 70,0 MPa CMC 3·10⁻⁶ · P + 0,002 MPa\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0 Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\nPrzetworniki cisnienia Wzorcowanie — Cisnienie\nZakres:\n- cisnienie wzgledne, podcisnienie i nadcisnienie (ciecz) 0 MPa do 0,1 MPa CMC 3,4·10⁻⁵ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (ciecz) 0,1 MPa do 0,6 MPa CMC 6,3·10⁻⁵ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (ciecz) 0,6 MPa do 2,0 MPa CMC 6·10⁻⁶ · P + 0,0002 MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (ciecz) 2,0 MPa do 70,0 MPa CMC 3·10⁻⁶ · P + 0,002 MPa\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0","search_en":"Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters Calibration — Pressure Internal procedure; At permanent location (S) Pressure Internal procedure At permanent location (S) - gauge pressure, negative and positive pressure (liquid) - gauge pressure, negative and positive pressure (liquid) - gauge pressure, negative and positive pressure (liquid) - gauge pressure, negative and positive pressure (liquid) Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":44,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Relativdruck, Unter- und Überdruck (Flüssigkeit)","range":"0 MPa to 0,1 MPa","cmc":"3,4·10⁻⁵ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Flüssigkeit)","range":"0,1 MPa to 0,6 MPa","cmc":"6,3·10⁻⁵ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Flüssigkeit)","range":"0,6 MPa to 2,0 MPa","cmc":"6·10⁻⁶ · P + 0,0002 MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Flüssigkeit)","range":"2,0 MPa to 70,0 MPa","cmc":"3·10⁻⁶ · P + 0,002 MPa"}],"reference_de":"Internes Verfahren PT 301, PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte Druckmessumformer Kalibrierung — Druck Internes Verfahren; Am festen Standort (S) Druck Internes Verfahren Am festen Standort (S) - Relativdruck, Unter- und Überdruck (Flüssigkeit) - Relativdruck, Unter- und Überdruck (Flüssigkeit) - Relativdruck, Unter- und Überdruck (Flüssigkeit) - Relativdruck, Unter- und Überdruck (Flüssigkeit) Internes Verfahren PT 301, PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\nDruckmessumformer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 表压，负压和正压（液体）","range":"0 MPa to 0,1 MPa","cmc":"3,4·10⁻⁵ MPa"},{"name":"- 表压，负压和正压（液体）","range":"0,1 MPa to 0,6 MPa","cmc":"6,3·10⁻⁵ MPa"},{"name":"- 表压，负压和正压（液体）","range":"0,6 MPa to 2,0 MPa","cmc":"6·10⁻⁶ · P + 0,0002 MPa"},{"name":"- 表压，负压和正压（液体）","range":"2,0 MPa to 70,0 MPa","cmc":"3·10⁻⁶ · P + 0,002 MPa"}],"reference_zh":"内部程序 PT 301, PT 302 依据EURAMET cg-17 v. 4.0","regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 压力变送器 校准 — 压力 内部程序；在固定地点 (S) 压力 内部程序 在固定地点 (S) - 表压，负压和正压（液体） - 表压，负压和正压（液体） - 表压，负压和正压（液体） - 表压，负压和正压（液体） 内部程序 PT 301, PT 302 依据EURAMET cg-17 v. 4.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"弹簧管压力表\n电子压力计\n压力变送器","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- přetlak, podtlak a přetlak (kapalina)","range":"0 MPa to 0,1 MPa","cmc":"3,4·10⁻⁵ MPa"},{"name":"- přetlak, podtlak a přetlak (kapalina)","range":"0,1 MPa to 0,6 MPa","cmc":"6,3·10⁻⁵ MPa"},{"name":"- přetlak, podtlak a přetlak (kapalina)","range":"0,6 MPa to 2,0 MPa","cmc":"6·10⁻⁶ · P + 0,0002 MPa"},{"name":"- přetlak, podtlak a přetlak (kapalina)","range":"2,0 MPa to 70,0 MPa","cmc":"3·10⁻⁶ · P + 0,002 MPa"}],"reference_cs":"Vnitřní postup PT 301, PT 302 na základě EURAMET cg-17 v. 4.0","regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry Převodníky tlaku Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) Tlak Vnitřní postup Ve stálé lokalitě (S) - přetlak, podtlak a přetlak (kapalina) - přetlak, podtlak a přetlak (kapalina) - přetlak, podtlak a přetlak (kapalina) - přetlak, podtlak a přetlak (kapalina) Vnitřní postup PT 301, PT 302 na základě EURAMET cg-17 v. 4.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\nPřevodníky tlaku"},{"_id":"9d7e342f29a3fc8a54fa5304","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\nPressure transmitters","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (ciecz)","range":"0 MPa do 1,0 MPa","cmc":"2,3·10⁻⁴ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (ciecz)","range":"1,0 MPa do 3,0 MPa","cmc":"4,7·10⁻⁴ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (ciecz)","range":"3,0 MPa do 10,0 MPa","cmc":"2,3·10⁻³ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (ciecz)","range":"10,0 MPa do 30,0 MPa","cmc":"4,7·10⁻³ MPa"},{"name":"- ciśnienie względne, podciśnienie i nadciśnienie (ciecz)","range":"30,0 MPa do 70,0 MPa","cmc":"1,0·10⁻² MPa"}],"parameters_en":[{"name":"- gauge pressure, negative and positive pressure (liquid)","range":"0 MPa to 1,0 MPa","cmc":"2,3·10⁻⁴ MPa"},{"name":"- gauge pressure, negative and positive pressure (liquid)","range":"1,0 MPa to 3,0 MPa","cmc":"4,7·10⁻⁴ MPa"},{"name":"- gauge pressure, negative and positive pressure (liquid)","range":"3,0 MPa to 10,0 MPa","cmc":"2,3·10⁻³ MPa"},{"name":"- gauge pressure, negative and positive pressure (liquid)","range":"10,0 MPa to 30,0 MPa","cmc":"4,7·10⁻³ MPa"},{"name":"- gauge pressure, negative and positive pressure (liquid)","range":"30,0 MPa to 70,0 MPa","cmc":"1,0·10⁻² MPa"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 0 MPa do 1,0 MPa CMC 2,3·10⁻⁴ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 1,0 MPa do 3,0 MPa CMC 4,7·10⁻⁴ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 3,0 MPa do 10,0 MPa CMC 2,3·10⁻³ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 10,0 MPa do 30,0 MPa CMC 4,7·10⁻³ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 30,0 MPa do 70,0 MPa CMC 1,0·10⁻² MPa\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0","norm_bases":["PT 301","PT 302","EURAMET cg-17 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"P","note":"P - wielkość mierzona (MPa)","note_en":"P - measured quantity (MPa)","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 0 MPa do 1,0 MPa CMC 2,3·10⁻⁴ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 1,0 MPa do 3,0 MPa CMC 4,7·10⁻⁴ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 3,0 MPa do 10,0 MPa CMC 2,3·10⁻³ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 10,0 MPa do 30,0 MPa CMC 4,7·10⁻³ MPa\n- ciśnienie względne, podciśnienie i nadciśnienie (ciecz) 30,0 MPa do 70,0 MPa CMC 1,0·10⁻² MPa\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0 Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\nPrzetworniki cisnienia Wzorcowanie — Cisnienie\nZakres:\n- cisnienie wzgledne, podcisnienie i nadcisnienie (ciecz) 0 MPa do 1,0 MPa CMC 2,3·10⁻⁴ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (ciecz) 1,0 MPa do 3,0 MPa CMC 4,7·10⁻⁴ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (ciecz) 3,0 MPa do 10,0 MPa CMC 2,3·10⁻³ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (ciecz) 10,0 MPa do 30,0 MPa CMC 4,7·10⁻³ MPa\n- cisnienie wzgledne, podcisnienie i nadcisnienie (ciecz) 30,0 MPa do 70,0 MPa CMC 1,0·10⁻² MPa\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0","search_en":"Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters Calibration — Pressure Internal procedure; Outside of permanent location (P) Pressure Internal procedure Outside of permanent location (P) - gauge pressure, negative and positive pressure (liquid) - gauge pressure, negative and positive pressure (liquid) - gauge pressure, negative and positive pressure (liquid) - gauge pressure, negative and positive pressure (liquid) - gauge pressure, negative and positive pressure (liquid) Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":45,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Relativdruck, Unter- und Überdruck (Flüssigkeit)","range":"0 MPa to 1,0 MPa","cmc":"2,3·10⁻⁴ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Flüssigkeit)","range":"1,0 MPa to 3,0 MPa","cmc":"4,7·10⁻⁴ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Flüssigkeit)","range":"3,0 MPa to 10,0 MPa","cmc":"2,3·10⁻³ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Flüssigkeit)","range":"10,0 MPa to 30,0 MPa","cmc":"4,7·10⁻³ MPa"},{"name":"- Relativdruck, Unter- und Überdruck (Flüssigkeit)","range":"30,0 MPa to 70,0 MPa","cmc":"1,0·10⁻² MPa"}],"reference_de":"Internes Verfahren PT 301, PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte Druckmessumformer Kalibrierung — Druck Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Druck Internes Verfahren Außerhalb des festen Standorts (P) - Relativdruck, Unter- und Überdruck (Flüssigkeit) - Relativdruck, Unter- und Überdruck (Flüssigkeit) - Relativdruck, Unter- und Überdruck (Flüssigkeit) - Relativdruck, Unter- und Überdruck (Flüssigkeit) - Relativdruck, Unter- und Überdruck (Flüssigkeit) Internes Verfahren PT 301, PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\nDruckmessumformer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 表压，负压和正压（液体）","range":"0 MPa to 1,0 MPa","cmc":"2,3·10⁻⁴ MPa"},{"name":"- 表压，负压和正压（液体）","range":"1,0 MPa to 3,0 MPa","cmc":"4,7·10⁻⁴ MPa"},{"name":"- 表压，负压和正压（液体）","range":"3,0 MPa to 10,0 MPa","cmc":"2,3·10⁻³ MPa"},{"name":"- 表压，负压和正压（液体）","range":"10,0 MPa to 30,0 MPa","cmc":"4,7·10⁻³ MPa"},{"name":"- 表压，负压和正压（液体）","range":"30,0 MPa to 70,0 MPa","cmc":"1,0·10⁻² MPa"}],"reference_zh":"内部程序 PT 301, PT 302 依据EURAMET cg-17 v. 4.0","regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 压力变送器 校准 — 压力 内部程序；固定地点以外 (P) 压力 内部程序 固定地点以外 (P) - 表压，负压和正压（液体） - 表压，负压和正压（液体） - 表压，负压和正压（液体） - 表压，负压和正压（液体） - 表压，负压和正压（液体） 内部程序 PT 301, PT 302 依据EURAMET cg-17 v. 4.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"弹簧管压力表\n电子压力计\n压力变送器","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- přetlak, podtlak a přetlak (kapalina)","range":"0 MPa to 1,0 MPa","cmc":"2,3·10⁻⁴ MPa"},{"name":"- přetlak, podtlak a přetlak (kapalina)","range":"1,0 MPa to 3,0 MPa","cmc":"4,7·10⁻⁴ MPa"},{"name":"- přetlak, podtlak a přetlak (kapalina)","range":"3,0 MPa to 10,0 MPa","cmc":"2,3·10⁻³ MPa"},{"name":"- přetlak, podtlak a přetlak (kapalina)","range":"10,0 MPa to 30,0 MPa","cmc":"4,7·10⁻³ MPa"},{"name":"- přetlak, podtlak a přetlak (kapalina)","range":"30,0 MPa to 70,0 MPa","cmc":"1,0·10⁻² MPa"}],"reference_cs":"Vnitřní postup PT 301, PT 302 na základě EURAMET cg-17 v. 4.0","regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry Převodníky tlaku Kalibrace — Tlak Vnitřní postup; Mimo stálé pracoviště (P) Tlak Vnitřní postup Mimo stálou lokalitu (P) - přetlak, podtlak a přetlak (kapalina) - přetlak, podtlak a přetlak (kapalina) - přetlak, podtlak a přetlak (kapalina) - přetlak, podtlak a přetlak (kapalina) - přetlak, podtlak a přetlak (kapalina) Vnitřní postup PT 301, PT 302 na základě EURAMET cg-17 v. 4.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\nPřevodníky tlaku"},{"_id":"3504afc3b470516ad2b041c6","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne (w tym barometry)\nPrzetworniki ciśnienia\nBarometry","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges (including barometers)\nPressure transmitters\nBarometers","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie absolutne","range":"0,0015 MPa abs do 0,12 MPa abs","cmc":"1,5·10⁻⁴ MPa"},{"name":"- ciśnienie absolutne","range":"0,12 MPa abs do 0,3 MPa abs","cmc":"1,8·10⁻⁴ MPa"},{"name":"- ciśnienie absolutne","range":"0,3 MPa abs do 0,6 MPa abs","cmc":"2,0·10⁻⁴ MPa"},{"name":"- ciśnienie absolutne","range":"0,6 MPa abs do 1,0 MPa abs","cmc":"2,3·10⁻⁴ MPa"},{"name":"- ciśnienie absolutne","range":"1,0 MPa abs do 3,0 MPa abs","cmc":"4,7·10⁻⁴ MPa"}],"parameters_en":[{"name":"- absolute pressure","range":"0,0015 MPa abs to 0,12 MPa abs","cmc":"1,5·10⁻⁴ MPa"},{"name":"- absolute pressure","range":"0,12 MPa abs to 0,3 MPa abs","cmc":"1,8·10⁻⁴ MPa"},{"name":"- absolute pressure","range":"0,3 MPa abs to 0,6 MPa abs","cmc":"2,0·10⁻⁴ MPa"},{"name":"- absolute pressure","range":"0,6 MPa abs to 1,0 MPa abs","cmc":"2,3·10⁻⁴ MPa"},{"name":"- absolute pressure","range":"1,0 MPa abs to 3,0 MPa abs","cmc":"4,7·10⁻⁴ MPa"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie absolutne 0,0015 MPa abs do 0,12 MPa abs CMC 1,5·10⁻⁴ MPa\n- ciśnienie absolutne 0,12 MPa abs do 0,3 MPa abs CMC 1,8·10⁻⁴ MPa\n- ciśnienie absolutne 0,3 MPa abs do 0,6 MPa abs CMC 2,0·10⁻⁴ MPa\n- ciśnienie absolutne 0,6 MPa abs do 1,0 MPa abs CMC 2,3·10⁻⁴ MPa\n- ciśnienie absolutne 1,0 MPa abs do 3,0 MPa abs CMC 4,7·10⁻⁴ MPa\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0","norm_bases":["PT 301","PT 302","EURAMET cg-17 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne (w tym barometry)\nPrzetworniki ciśnienia\nBarometry Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie absolutne 0,0015 MPa abs do 0,12 MPa abs CMC 1,5·10⁻⁴ MPa\n- ciśnienie absolutne 0,12 MPa abs do 0,3 MPa abs CMC 1,8·10⁻⁴ MPa\n- ciśnienie absolutne 0,3 MPa abs do 0,6 MPa abs CMC 2,0·10⁻⁴ MPa\n- ciśnienie absolutne 0,6 MPa abs do 1,0 MPa abs CMC 2,3·10⁻⁴ MPa\n- ciśnienie absolutne 1,0 MPa abs do 3,0 MPa abs CMC 4,7·10⁻⁴ MPa\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0 Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne (w tym barometry)\nPrzetworniki cisnienia\nBarometry Wzorcowanie — Cisnienie\nZakres:\n- cisnienie absolutne 0,0015 MPa abs do 0,12 MPa abs CMC 1,5·10⁻⁴ MPa\n- cisnienie absolutne 0,12 MPa abs do 0,3 MPa abs CMC 1,8·10⁻⁴ MPa\n- cisnienie absolutne 0,3 MPa abs do 0,6 MPa abs CMC 2,0·10⁻⁴ MPa\n- cisnienie absolutne 0,6 MPa abs do 1,0 MPa abs CMC 2,3·10⁻⁴ MPa\n- cisnienie absolutne 1,0 MPa abs do 3,0 MPa abs CMC 4,7·10⁻⁴ MPa\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0","search_en":"Bourdon tube pressure gauges Electronic pressure gauges (including barometers) Pressure transmitters Barometers Calibration — Pressure Internal procedure; At permanent location (S) Pressure Internal procedure At permanent location (S) - absolute pressure - absolute pressure - absolute pressure - absolute pressure - absolute pressure Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":46,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Absolutdruck","range":"0,0015 MPa abs to 0,12 MPa abs","cmc":"1,5·10⁻⁴ MPa"},{"name":"- Absolutdruck","range":"0,12 MPa abs to 0,3 MPa abs","cmc":"1,8·10⁻⁴ MPa"},{"name":"- Absolutdruck","range":"0,3 MPa abs to 0,6 MPa abs","cmc":"2,0·10⁻⁴ MPa"},{"name":"- Absolutdruck","range":"0,6 MPa abs to 1,0 MPa abs","cmc":"2,3·10⁻⁴ MPa"},{"name":"- Absolutdruck","range":"1,0 MPa abs to 3,0 MPa abs","cmc":"4,7·10⁻⁴ MPa"}],"reference_de":"Internes Verfahren PT 301, PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte (einschließlich Barometer) Druckmessumformer Barometer Kalibrierung — Druck Internes Verfahren; Am festen Standort (S) Druck Internes Verfahren Am festen Standort (S) - Absolutdruck - Absolutdruck - Absolutdruck - Absolutdruck - Absolutdruck Internes Verfahren PT 301, PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte (einschließlich Barometer)\nDruckmessumformer\nBarometer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 绝对压力","range":"0,0015 MPa abs to 0,12 MPa abs","cmc":"1,5·10⁻⁴ MPa"},{"name":"- 绝对压力","range":"0,12 MPa abs to 0,3 MPa abs","cmc":"1,8·10⁻⁴ MPa"},{"name":"- 绝对压力","range":"0,3 MPa abs to 0,6 MPa abs","cmc":"2,0·10⁻⁴ MPa"},{"name":"- 绝对压力","range":"0,6 MPa abs to 1,0 MPa abs","cmc":"2,3·10⁻⁴ MPa"},{"name":"- 绝对压力","range":"1,0 MPa abs to 3,0 MPa abs","cmc":"4,7·10⁻⁴ MPa"}],"reference_zh":"内部程序 PT 301, PT 302 依据EURAMET cg-17 v. 4.0","regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计（包括气压计） 压力变送器 气压计 校准 — 压力 内部程序；在固定地点 (S) 压力 内部程序 在固定地点 (S) - 绝对压力 - 绝对压力 - 绝对压力 - 绝对压力 - 绝对压力 内部程序 PT 301, PT 302 依据EURAMET cg-17 v. 4.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"弹簧管压力表\n电子压力计（包括气压计）\n压力变送器\n气压计","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- absolutní tlak","range":"0,0015 MPa abs to 0,12 MPa abs","cmc":"1,5·10⁻⁴ MPa"},{"name":"- absolutní tlak","range":"0,12 MPa abs to 0,3 MPa abs","cmc":"1,8·10⁻⁴ MPa"},{"name":"- absolutní tlak","range":"0,3 MPa abs to 0,6 MPa abs","cmc":"2,0·10⁻⁴ MPa"},{"name":"- absolutní tlak","range":"0,6 MPa abs to 1,0 MPa abs","cmc":"2,3·10⁻⁴ MPa"},{"name":"- absolutní tlak","range":"1,0 MPa abs to 3,0 MPa abs","cmc":"4,7·10⁻⁴ MPa"}],"reference_cs":"Vnitřní postup PT 301, PT 302 na základě EURAMET cg-17 v. 4.0","regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry (včetně barometrů) Převodníky tlaku Barometry Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) Tlak Vnitřní postup Ve stálé lokalitě (S) - absolutní tlak - absolutní tlak - absolutní tlak - absolutní tlak - absolutní tlak Vnitřní postup PT 301, PT 302 na základě EURAMET cg-17 v. 4.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry (včetně barometrů)\nPřevodníky tlaku\nBarometry"},{"_id":"51b8f29f134a615b5151a84d","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne (w tym barometry)\nPrzetworniki ciśnienia\nBarometry","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges (including barometers)\nPressure transmitters\nBarometers","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie absolutne","range":"0,0015 MPa abs do 0,3 MPa abs","cmc":"2,4·10⁻⁴ MPa"},{"name":"- ciśnienie absolutne","range":"0,3 MPa abs do 1,0 MPa abs","cmc":"6,0·10⁻⁴ MPa"},{"name":"- ciśnienie absolutne","range":"1,0 MPa abs do 3,0 MPa abs","cmc":"1,8·10⁻³ MPa"}],"parameters_en":[{"name":"- absolute pressure","range":"0,0015 MPa abs to 0,3 MPa abs","cmc":"2,4·10⁻⁴ MPa"},{"name":"- absolute pressure","range":"0,3 MPa abs to 1,0 MPa abs","cmc":"6,0·10⁻⁴ MPa"},{"name":"- absolute pressure","range":"1,0 MPa abs to 3,0 MPa abs","cmc":"1,8·10⁻³ MPa"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie absolutne 0,0015 MPa abs do 0,3 MPa abs CMC 2,4·10⁻⁴ MPa\n- ciśnienie absolutne 0,3 MPa abs do 1,0 MPa abs CMC 6,0·10⁻⁴ MPa\n- ciśnienie absolutne 1,0 MPa abs do 3,0 MPa abs CMC 1,8·10⁻³ MPa\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0","norm_bases":["PT 301","PT 302","EURAMET cg-17 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne (w tym barometry)\nPrzetworniki ciśnienia\nBarometry Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie absolutne 0,0015 MPa abs do 0,3 MPa abs CMC 2,4·10⁻⁴ MPa\n- ciśnienie absolutne 0,3 MPa abs do 1,0 MPa abs CMC 6,0·10⁻⁴ MPa\n- ciśnienie absolutne 1,0 MPa abs do 3,0 MPa abs CMC 1,8·10⁻³ MPa\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0 Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne (w tym barometry)\nPrzetworniki cisnienia\nBarometry Wzorcowanie — Cisnienie\nZakres:\n- cisnienie absolutne 0,0015 MPa abs do 0,3 MPa abs CMC 2,4·10⁻⁴ MPa\n- cisnienie absolutne 0,3 MPa abs do 1,0 MPa abs CMC 6,0·10⁻⁴ MPa\n- cisnienie absolutne 1,0 MPa abs do 3,0 MPa abs CMC 1,8·10⁻³ MPa\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 301, PT 302 w oparciu o EURAMET cg-17 v. 4.0","search_en":"Bourdon tube pressure gauges Electronic pressure gauges (including barometers) Pressure transmitters Barometers Calibration — Pressure Internal procedure; Outside of permanent location (P) Pressure Internal procedure Outside of permanent location (P) - absolute pressure - absolute pressure - absolute pressure Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":47,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 301, PT 302 based on EURAMET cg-17 v. 4.0","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Absolutdruck","range":"0,0015 MPa abs to 0,3 MPa abs","cmc":"2,4·10⁻⁴ MPa"},{"name":"- Absolutdruck","range":"0,3 MPa abs to 1,0 MPa abs","cmc":"6,0·10⁻⁴ MPa"},{"name":"- Absolutdruck","range":"1,0 MPa abs to 3,0 MPa abs","cmc":"1,8·10⁻³ MPa"}],"reference_de":"Internes Verfahren PT 301, PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte (einschließlich Barometer) Druckmessumformer Barometer Kalibrierung — Druck Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Druck Internes Verfahren Außerhalb des festen Standorts (P) - Absolutdruck - Absolutdruck - Absolutdruck Internes Verfahren PT 301, PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte (einschließlich Barometer)\nDruckmessumformer\nBarometer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 绝对压力","range":"0,0015 MPa abs to 0,3 MPa abs","cmc":"2,4·10⁻⁴ MPa"},{"name":"- 绝对压力","range":"0,3 MPa abs to 1,0 MPa abs","cmc":"6,0·10⁻⁴ MPa"},{"name":"- 绝对压力","range":"1,0 MPa abs to 3,0 MPa abs","cmc":"1,8·10⁻³ MPa"}],"reference_zh":"内部程序 PT 301, PT 302 依据EURAMET cg-17 v. 4.0","regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计（包括气压计） 压力变送器 气压计 校准 — 压力 内部程序；固定地点以外 (P) 压力 内部程序 固定地点以外 (P) - 绝对压力 - 绝对压力 - 绝对压力 内部程序 PT 301, PT 302 依据EURAMET cg-17 v. 4.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"弹簧管压力表\n电子压力计（包括气压计）\n压力变送器\n气压计","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- absolutní tlak","range":"0,0015 MPa abs to 0,3 MPa abs","cmc":"2,4·10⁻⁴ MPa"},{"name":"- absolutní tlak","range":"0,3 MPa abs to 1,0 MPa abs","cmc":"6,0·10⁻⁴ MPa"},{"name":"- absolutní tlak","range":"1,0 MPa abs to 3,0 MPa abs","cmc":"1,8·10⁻³ MPa"}],"reference_cs":"Vnitřní postup PT 301, PT 302 na základě EURAMET cg-17 v. 4.0","regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry (včetně barometrů) Převodníky tlaku Barometry Kalibrace — Tlak Vnitřní postup; Mimo stálé pracoviště (P) Tlak Vnitřní postup Mimo stálou lokalitu (P) - absolutní tlak - absolutní tlak - absolutní tlak Vnitřní postup PT 301, PT 302 na základě EURAMET cg-17 v. 4.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry (včetně barometrů)\nPřevodníky tlaku\nBarometry"},{"_id":"5c9403c3f64272d710e0bdea","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Barometry","test_object_en":"Barometers","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie absolutne","range":"300 hPa abs do 1200 hPa abs","cmc":"1,5 hPa"}],"parameters_en":[{"name":"- absolute pressure","range":"300 hPa abs to 1200 hPa abs","cmc":"1,5 hPa"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\n- ciśnienie absolutne 300 hPa abs do 1200 hPa abs CMC 1,5 hPa\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 302 w oparciu o EURAMET cg-17 v. 4.0","norm_bases":["PT 302","EURAMET cg-17 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Barometry Wzorcowanie — Ciśnienie\n- ciśnienie absolutne 300 hPa abs do 1200 hPa abs CMC 1,5 hPa\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 302 w oparciu o EURAMET cg-17 v. 4.0 Barometry Wzorcowanie — Cisnienie\n- cisnienie absolutne 300 hPa abs do 1200 hPa abs CMC 1,5 hPa\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 302 w oparciu o EURAMET cg-17 v. 4.0","search_en":"Barometers Calibration — Pressure Internal procedure; At permanent location (S) Pressure Internal procedure At permanent location (S) - absolute pressure Internal procedure PT 302 based on EURAMET cg-17 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":48,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 302 based on EURAMET cg-17 v. 4.0","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Absolutdruck","range":"300 hPa abs to 1200 hPa abs","cmc":"1,5 hPa"}],"reference_de":"Internes Verfahren PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","regulatory_area_de":"Druck","search_de":"Barometer Kalibrierung — Druck Internes Verfahren; Am festen Standort (S) Druck Internes Verfahren Am festen Standort (S) - Absolutdruck Internes Verfahren PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Barometer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 绝对压力","range":"300 hPa abs to 1200 hPa abs","cmc":"1,5 hPa"}],"reference_zh":"内部程序 PT 302 依据EURAMET cg-17 v. 4.0","regulatory_area_zh":"压力","search_zh":"气压计 校准 — 压力 内部程序；在固定地点 (S) 压力 内部程序 在固定地点 (S) - 绝对压力 内部程序 PT 302 依据EURAMET cg-17 v. 4.0","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"气压计","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- absolutní tlak","range":"300 hPa abs to 1200 hPa abs","cmc":"1,5 hPa"}],"reference_cs":"Vnitřní postup PT 302 na základě EURAMET cg-17 v. 4.0","regulatory_area_cs":"Tlak","search_cs":"Barometry Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) Tlak Vnitřní postup Ve stálé lokalitě (S) - absolutní tlak Vnitřní postup PT 302 na základě EURAMET cg-17 v. 4.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Barometry"},{"_id":"1b3c010575e37e5caf3d2704","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Barometry","test_object_en":"Barometers","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie absolutne","range":"300 hPa abs do 1200 hPa abs","cmc":"2,4 hPa"}],"parameters_en":[{"name":"- absolute pressure","range":"300 hPa abs to 1200 hPa abs","cmc":"2,4 hPa"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\n- ciśnienie absolutne 300 hPa abs do 1200 hPa abs CMC 2,4 hPa\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 302 w oparciu o EURAMET cg-17 v. 4.0","norm_bases":["PT 302","EURAMET cg-17 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Barometry Wzorcowanie — Ciśnienie\n- ciśnienie absolutne 300 hPa abs do 1200 hPa abs CMC 2,4 hPa\nProcedura wewnętrzna; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 302 w oparciu o EURAMET cg-17 v. 4.0 Barometry Wzorcowanie — Cisnienie\n- cisnienie absolutne 300 hPa abs do 1200 hPa abs CMC 2,4 hPa\nProcedura wewnetrzna; Poza stala lokalizacja (P) Procedura wewnetrzna PT 302 w oparciu o EURAMET cg-17 v. 4.0","search_en":"Barometers Calibration — Pressure Internal procedure; Outside of permanent location (P) Pressure Internal procedure Outside of permanent location (P) - absolute pressure Internal procedure PT 302 based on EURAMET cg-17 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":49,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 302 based on EURAMET cg-17 v. 4.0","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Absolutdruck","range":"300 hPa abs to 1200 hPa abs","cmc":"2,4 hPa"}],"reference_de":"Internes Verfahren PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","regulatory_area_de":"Druck","search_de":"Barometer Kalibrierung — Druck Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Druck Internes Verfahren Außerhalb des festen Standorts (P) - Absolutdruck Internes Verfahren PT 302 auf Grundlage von EURAMET cg-17 v. 4.0","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Barometer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 绝对压力","range":"300 hPa abs to 1200 hPa abs","cmc":"2,4 hPa"}],"reference_zh":"内部程序 PT 302 依据EURAMET cg-17 v. 4.0","regulatory_area_zh":"压力","search_zh":"气压计 校准 — 压力 内部程序；固定地点以外 (P) 压力 内部程序 固定地点以外 (P) - 绝对压力 内部程序 PT 302 依据EURAMET cg-17 v. 4.0","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"气压计","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- absolutní tlak","range":"300 hPa abs to 1200 hPa abs","cmc":"2,4 hPa"}],"reference_cs":"Vnitřní postup PT 302 na základě EURAMET cg-17 v. 4.0","regulatory_area_cs":"Tlak","search_cs":"Barometry Kalibrace — Tlak Vnitřní postup; Mimo stálé pracoviště (P) Tlak Vnitřní postup Mimo stálou lokalitu (P) - absolutní tlak Vnitřní postup PT 302 na základě EURAMET cg-17 v. 4.0","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Barometry"},{"_id":"2a9eb530261ba69266cbfca6","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Czujniki termometrów rezystancyjnych","test_object_en":"Resistance thermometer sensors","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"}],"parameters_en":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,03 °C\n100 °C do 200 °C CMC 0,05 °C\n200 °C do 650 °C CMC 0,15 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 201","norm_bases":["PT 201"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki termometrów rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,03 °C\n100 °C do 200 °C CMC 0,05 °C\n200 °C do 650 °C CMC 0,15 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 201 Czujniki termometrow rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,03 °C\n100 °C do 200 °C CMC 0,05 °C\n200 °C do 650 °C CMC 0,15 °C\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 201","search_en":"Resistance thermometer sensors Calibration — Temperature (electrical thermometry) Internal procedure; Indirect method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Indirect method At permanent location (S) Internal procedure PT 201","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":50,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 201","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C bis 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"}],"reference_de":"Internes Verfahren PT 201","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Fühler von Widerstandsthermometern Kalibrierung — Temperatur (elektrische Thermometrie) Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Indirektes Verfahren Am festen Standort (S) Internes Verfahren PT 201","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Fühler von Widerstandsthermometern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"}],"reference_zh":"内部程序 PT 201","regulatory_area_zh":"温度（电测温）","search_zh":"电阻温度计传感器 校准 — 温度（电测温） 内部程序；间接方法；固定地点（S） 温度（电测温） 内部程序 间接法 在固定地点 (S) 内部程序 PT 201","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"电阻温度计传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"}],"reference_cs":"Vnitřní postup PT 201","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Čidla odporových teploměrů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 201","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Čidla odporových teploměrů"},{"_id":"cd198cb59d23d15ff4bc73c5","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Czujniki termometrów rezystancyjnych","test_object_en":"Resistance thermometer sensors","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,05 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,15 °C"}],"parameters_en":[{"name":"","range":"-35 °C to 150 °C","cmc":"0,05 °C"},{"name":"","range":"150 °C to 650 °C","cmc":"0,15 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Indirect method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda pośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Indirect method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-35 °C do 150 °C CMC 0,05 °C\n150 °C do 650 °C CMC 0,15 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 201","norm_bases":["PT 201"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Czujniki termometrów rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-35 °C do 150 °C CMC 0,05 °C\n150 °C do 650 °C CMC 0,15 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 201 Czujniki termometrow rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-35 °C do 150 °C CMC 0,05 °C\n150 °C do 650 °C CMC 0,15 °C\nProcedura wewnetrzna; Metoda posrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 201","search_en":"Resistance thermometer sensors Calibration — Temperature (electrical thermometry) Internal procedure; Indirect method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Indirect method Outside of permanent location (P) Internal procedure PT 201","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":51,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 201","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-35 °C to 150 °C","cmc":"0,05 °C"},{"name":"","range":"150 °C to 650 °C","cmc":"0,15 °C"}],"reference_de":"Internes Verfahren PT 201","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Fühler von Widerstandsthermometern Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Indirektes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 201","technique_de":"Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Fühler von Widerstandsthermometern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-35 °C to 150 °C","cmc":"0,05 °C"},{"name":"","range":"150 °C to 650 °C","cmc":"0,15 °C"}],"reference_zh":"内部程序 PT 201","regulatory_area_zh":"温度（电测温）","search_zh":"电阻温度计传感器 校准 — 温度（电测温） 内部程序；间接法；固定地点以外 (P) 温度（电测温） 内部程序 间接法 固定地点以外 (P) 内部程序 PT 201","technique_zh":"内部程序；间接法；固定地点以外 (P)","techniques_zh":["内部程序","间接法","固定地点以外 (P)"],"test_object_zh":"电阻温度计传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-35 °C to 150 °C","cmc":"0,05 °C"},{"name":"","range":"150 °C to 650 °C","cmc":"0,15 °C"}],"reference_cs":"Vnitřní postup PT 201","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Čidla odporových teploměrů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Nepřímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 201","technique_cs":"Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Čidla odporových teploměrů"},{"_id":"ddc934d51641b10e954810e3","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych","test_object_en":"Noble metal thermocouples\nBase metal thermocouples","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,3 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,4 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,5 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,3 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,4 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,5 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,2 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,3 °C\n100 °C do 200 °C CMC 0,4 °C\n200 °C do 650 °C CMC 0,5 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 201 w oparciu o EURAMET cg-8 v. 3.1","norm_bases":["PT 201","EURAMET cg-8 v. 3.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,3 °C\n100 °C do 200 °C CMC 0,4 °C\n200 °C do 650 °C CMC 0,5 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 201 w oparciu o EURAMET cg-8 v. 3.1 Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,3 °C\n100 °C do 200 °C CMC 0,4 °C\n200 °C do 650 °C CMC 0,5 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 201 w oparciu o EURAMET cg-8 v. 3.1","search_en":"Noble metal thermocouples Base metal thermocouples Calibration — Temperature (electrical thermometry) Internal procedure; Indirect method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Indirect method At permanent location (S) Internal procedure PT 201 based on EURAMET cg-8 v. 3.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":52,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 201 based on EURAMET cg-8 v. 3.1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,3 °C"},{"name":"","range":"100 °C bis 200 °C","cmc":"0,4 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,5 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,2 °C"}],"reference_de":"Internes Verfahren PT 201 auf Grundlage von EURAMET cg-8 v. 3.1","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Edelmetall-Thermoelemente Thermoelemente aus unedlen Metallen Kalibrierung — Temperatur (elektrische Thermometrie) Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Indirektes Verfahren Am festen Standort (S) Internes Verfahren PT 201 auf Grundlage von EURAMET cg-8 v. 3.1","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Edelmetall-Thermoelemente\nThermoelemente aus unedlen Metallen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,3 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,4 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,5 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,2 °C"}],"reference_zh":"内部程序 PT 201 依据EURAMET cg-8 v. 3.1","regulatory_area_zh":"温度（电测温）","search_zh":"贵金属热电偶 贱金属热电偶传感器 校准 — 温度（电测温） 内部程序；间接方法；固定地点（S） 温度（电测温） 内部程序 间接法 在固定地点 (S) 内部程序 PT 201 依据EURAMET cg-8 v. 3.1","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"贵金属热电偶\n贱金属热电偶传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,3 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,4 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,5 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"reference_cs":"Vnitřní postup PT 201 na základě EURAMET cg-8 v. 3.1","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Termoelektrické snímače z drahých kovů Termoelektrické snímače z obecných kovů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 201 na základě EURAMET cg-8 v. 3.1","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Termoelektrické snímače z drahých kovů\nTermoelektrické snímače z obecných kovů"},{"_id":"f3497f4eaffe47d85c96fbbb","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych","test_object_en":"Noble metal thermocouples\nBase metal thermocouples","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,5 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,7 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"1,0 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,5 °C"}],"parameters_en":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,5 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,7 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"1,0 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,5 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Indirect method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda pośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Indirect method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-35 °C do 150 °C CMC 0,5 °C\n150 °C do 650 °C CMC 0,7 °C\n650 °C do 1085 °C CMC 1,0 °C\n1085 °C do 1200 °C CMC 1,5 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 201 w oparciu o EURAMET cg-8 v. 3.1","norm_bases":["PT 201","EURAMET cg-8 v. 3.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-35 °C do 150 °C CMC 0,5 °C\n150 °C do 650 °C CMC 0,7 °C\n650 °C do 1085 °C CMC 1,0 °C\n1085 °C do 1200 °C CMC 1,5 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 201 w oparciu o EURAMET cg-8 v. 3.1 Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-35 °C do 150 °C CMC 0,5 °C\n150 °C do 650 °C CMC 0,7 °C\n650 °C do 1085 °C CMC 1,0 °C\n1085 °C do 1200 °C CMC 1,5 °C\nProcedura wewnetrzna; Metoda posrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 201 w oparciu o EURAMET cg-8 v. 3.1","search_en":"Noble metal thermocouples Base metal thermocouples Calibration — Temperature (electrical thermometry) Internal procedure; Indirect method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Indirect method Outside of permanent location (P) Internal procedure PT 201 based on EURAMET cg-8 v. 3.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":53,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 201 based on EURAMET cg-8 v. 3.1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,5 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,7 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"1,0 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,5 °C"}],"reference_de":"Internes Verfahren PT 201 auf Grundlage von EURAMET cg-8 v. 3.1","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Edelmetall-Thermoelemente Thermoelemente aus unedlen Metallen Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Indirektes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 201 auf Grundlage von EURAMET cg-8 v. 3.1","technique_de":"Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Edelmetall-Thermoelemente\nThermoelemente aus unedlen Metallen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,5 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,7 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"1,0 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,5 °C"}],"reference_zh":"内部程序 PT 201 依据EURAMET cg-8 v. 3.1","regulatory_area_zh":"温度（电测温）","search_zh":"贵金属热电偶 贱金属热电偶传感器 校准 — 温度（电测温） 内部程序；间接法；固定地点以外 (P) 温度（电测温） 内部程序 间接法 固定地点以外 (P) 内部程序 PT 201 依据EURAMET cg-8 v. 3.1","technique_zh":"内部程序；间接法；固定地点以外 (P)","techniques_zh":["内部程序","间接法","固定地点以外 (P)"],"test_object_zh":"贵金属热电偶\n贱金属热电偶传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,5 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,7 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"1,0 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,5 °C"}],"reference_cs":"Vnitřní postup PT 201 na základě EURAMET cg-8 v. 3.1","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Termoelektrické snímače z drahých kovů Termoelektrické snímače z obecných kovů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Nepřímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 201 na základě EURAMET cg-8 v. 3.1","technique_cs":"Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Termoelektrické snímače z drahých kovů\nTermoelektrické snímače z obecných kovů"},{"_id":"a1319969102acad50a11a59f","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Przetworniki temperatury (z czujnikiem temperatury)","test_object_en":"Temperature transmitters (with temperature sensor)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,2 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,03 °C\n100 °C do 200 °C CMC 0,05 °C\n200 °C do 650 °C CMC 0,15 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 202","norm_bases":["PT 202"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przetworniki temperatury (z czujnikiem temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,03 °C\n100 °C do 200 °C CMC 0,05 °C\n200 °C do 650 °C CMC 0,15 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 202 Przetworniki temperatury (z czujnikiem temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,03 °C\n100 °C do 200 °C CMC 0,05 °C\n200 °C do 650 °C CMC 0,15 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 202","search_en":"Temperature transmitters (with temperature sensor) Calibration — Temperature (electrical thermometry) Internal procedure; Indirect method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Indirect method At permanent location (S) Internal procedure PT 202","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":54,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 202","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C bis 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,2 °C"}],"reference_de":"Internes Verfahren PT 202","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Temperaturmessumformer (mit Temperaturfühler) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Indirektes Verfahren Am festen Standort (S) Internes Verfahren PT 202","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Temperaturmessumformer (mit Temperaturfühler)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,2 °C"}],"reference_zh":"内部程序 PT 202","regulatory_area_zh":"温度（电测温）","search_zh":"温度变送器（带温度传感器） 校准 — 温度（电测温） 内部程序；间接方法；固定地点（S） 温度（电测温） 内部程序 间接法 在固定地点 (S) 内部程序 PT 202","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"温度变送器（带温度传感器）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"reference_cs":"Vnitřní postup PT 202","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Převodníky teploty (s teplotním čidlem) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 202","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Převodníky teploty (s teplotním čidlem)"},{"_id":"ed94caf71ed4e7d109c89eeb","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Przetworniki temperatury (z czujnikiem temperatury)","test_object_en":"Temperature transmitters (with temperature sensor)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,1 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,1 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,2 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Indirect method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda pośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Indirect method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-35 °C do 150 °C CMC 0,1 °C\n150 °C do 650 °C CMC 0,2 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 202","norm_bases":["PT 202"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Przetworniki temperatury (z czujnikiem temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-35 °C do 150 °C CMC 0,1 °C\n150 °C do 650 °C CMC 0,2 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 202 Przetworniki temperatury (z czujnikiem temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-35 °C do 150 °C CMC 0,1 °C\n150 °C do 650 °C CMC 0,2 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnetrzna; Metoda posrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 202","search_en":"Temperature transmitters (with temperature sensor) Calibration — Temperature (electrical thermometry) Internal procedure; Indirect method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Indirect method Outside of permanent location (P) Internal procedure PT 202","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":55,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 202","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,1 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,2 °C"}],"reference_de":"Internes Verfahren PT 202","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Temperaturmessumformer (mit Temperaturfühler) Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Indirektes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 202","technique_de":"Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Temperaturmessumformer (mit Temperaturfühler)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,1 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,2 °C"}],"reference_zh":"内部程序 PT 202","regulatory_area_zh":"温度（电测温）","search_zh":"温度变送器（带温度传感器） 校准 — 温度（电测温） 内部程序；间接法；固定地点以外 (P) 温度（电测温） 内部程序 间接法 固定地点以外 (P) 内部程序 PT 202","technique_zh":"内部程序；间接法；固定地点以外 (P)","techniques_zh":["内部程序","间接法","固定地点以外 (P)"],"test_object_zh":"温度变送器（带温度传感器）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,1 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"reference_cs":"Vnitřní postup PT 202","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Převodníky teploty (s teplotním čidlem) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Nepřímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 202","technique_cs":"Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Převodníky teploty (s teplotním čidlem)"},{"_id":"ac8fa7a57750c08d5cfb3616","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (with temperature recording)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,2 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,03 °C\n100 °C do 200 °C CMC 0,05 °C\n200 °C do 650 °C CMC 0,15 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 203","norm_bases":["PT 203"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,03 °C\n100 °C do 200 °C CMC 0,05 °C\n200 °C do 650 °C CMC 0,15 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 203 Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,03 °C\n100 °C do 200 °C CMC 0,05 °C\n200 °C do 650 °C CMC 0,15 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 203","search_en":"Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Calibration — Temperature (electrical thermometry) Internal procedure; Indirect method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Indirect method At permanent location (S) Internal procedure PT 203","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":56,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 203","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C bis 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,2 °C"}],"reference_de":"Internes Verfahren PT 203","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Indirektes Verfahren Am festen Standort (S) Internes Verfahren PT 203","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,2 °C"}],"reference_zh":"内部程序 PT 203","regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序；间接方法；固定地点（S） 温度（电测温） 内部程序 间接法 在固定地点 (S) 内部程序 PT 203","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,05 °C"},{"name":"","range":"200 °C do 650 °C","cmc":"0,15 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"reference_cs":"Vnitřní postup PT 203","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 203","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"},{"_id":"6ed092d23af3a42184318b22","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (with temperature recording)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,1 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,1 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,2 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Indirect method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda pośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Indirect method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-35 °C do 150 °C CMC 0,1 °C\n150 °C do 650 °C CMC 0,2 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 203","norm_bases":["PT 203"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-35 °C do 150 °C CMC 0,1 °C\n150 °C do 650 °C CMC 0,2 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 203 Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-35 °C do 150 °C CMC 0,1 °C\n150 °C do 650 °C CMC 0,2 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnetrzna; Metoda posrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 203","search_en":"Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Calibration — Temperature (electrical thermometry) Internal procedure; Indirect method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Indirect method Outside of permanent location (P) Internal procedure PT 203","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":57,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 203","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,1 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,2 °C"}],"reference_de":"Internes Verfahren PT 203","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Indirektes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 203","technique_de":"Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,1 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,2 °C"}],"reference_zh":"内部程序 PT 203","regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序；间接法；固定地点以外 (P) 温度（电测温） 内部程序 间接法 固定地点以外 (P) 内部程序 PT 203","technique_zh":"内部程序；间接法；固定地点以外 (P)","techniques_zh":["内部程序","间接法","固定地点以外 (P)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-35 °C do 150 °C","cmc":"0,1 °C"},{"name":"","range":"150 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"reference_cs":"Vnitřní postup PT 203","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Nepřímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 203","technique_cs":"Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"},{"_id":"10ca72fd99f1fa53282eed68","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Termostaty cieczowe","test_object_en":"Liquid baths","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C do 250 °C","cmc":"0,03 °C"}],"parameters_en":[{"name":"","range":"-100 °C to 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C to 250 °C","cmc":"0,03 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,02 °C\n100 °C do 250 °C CMC 0,03 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 206","norm_bases":["PT 206"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,02 °C\n100 °C do 250 °C CMC 0,03 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 206 Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,02 °C\n100 °C do 250 °C CMC 0,03 °C\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 206","search_en":"Liquid baths Calibration — Temperature (electrical thermometry) Internal procedure; Indirect method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Indirect method At permanent location (S) Internal procedure PT 206","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":58,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 206","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C to 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C to 250 °C","cmc":"0,03 °C"}],"reference_de":"Internes Verfahren PT 206","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Flüssigkeitsthermostate Kalibrierung — Temperatur (elektrische Thermometrie) Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Indirektes Verfahren Am festen Standort (S) Internes Verfahren PT 206","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Flüssigkeitsthermostate","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C to 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C to 250 °C","cmc":"0,03 °C"}],"reference_zh":"内部程序 PT 206","regulatory_area_zh":"温度（电测温）","search_zh":"液体恒温槽 校准 — 温度（电测温） 内部程序；间接方法；固定地点（S） 温度（电测温） 内部程序 间接法 在固定地点 (S) 内部程序 PT 206","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"液体恒温槽","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C to 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C to 250 °C","cmc":"0,03 °C"}],"reference_cs":"Vnitřní postup PT 206","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Kapalinové termostaty Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 206","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kapalinové termostaty"},{"_id":"1a09b4386b2d76d39801785e","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Termostaty cieczowe","test_object_en":"Liquid baths","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-100 °C do 250 °C","cmc":"0,03 °C"}],"parameters_en":[{"name":"","range":"-100 °C to 250 °C","cmc":"0,03 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Indirect method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda pośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Indirect method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-100 °C do 250 °C CMC 0,03 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 206","norm_bases":["PT 206"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-100 °C do 250 °C CMC 0,03 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 206 Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-100 °C do 250 °C CMC 0,03 °C\nProcedura wewnetrzna; Metoda posrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 206","search_en":"Liquid baths Calibration — Temperature (electrical thermometry) Internal procedure; Indirect method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Indirect method Outside of permanent location (P) Internal procedure PT 206","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":59,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 206","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C to 250 °C","cmc":"0,03 °C"}],"reference_de":"Internes Verfahren PT 206","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Flüssigkeitsthermostate Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Indirektes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 206","technique_de":"Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Flüssigkeitsthermostate","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C to 250 °C","cmc":"0,03 °C"}],"reference_zh":"内部程序 PT 206","regulatory_area_zh":"温度（电测温）","search_zh":"液体恒温槽 校准 — 温度（电测温） 内部程序；间接法；固定地点以外 (P) 温度（电测温） 内部程序 间接法 固定地点以外 (P) 内部程序 PT 206","technique_zh":"内部程序；间接法；固定地点以外 (P)","techniques_zh":["内部程序","间接法","固定地点以外 (P)"],"test_object_zh":"液体恒温槽","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C to 250 °C","cmc":"0,03 °C"}],"reference_cs":"Vnitřní postup PT 206","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Kapalinové termostaty Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Nepřímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 206","technique_cs":"Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Kapalinové termostaty"},{"_id":"c915fd23d76bf3daae704f79","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Komory termostatyczne","test_object_en":"Thermostatic chambers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C do 400 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C to 400 °C","cmc":"0,2 °C"}],"technique":"Procedura wewnętrzna; Wzorcowanie i pomiar. Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Calibration and measurement. Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Wzorcowanie i pomiar. Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Calibration and measurement. Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,05 °C\n100 °C do 200 °C CMC 0,1 °C\n200 °C do 400 °C CMC 0,2 °C\nProcedura wewnętrzna; Wzorcowanie i pomiar. Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 206 w oparciu o EURAMET cg-20 v. 5.0","norm_bases":["PT 206","EURAMET cg-20 v. 5.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Komory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,05 °C\n100 °C do 200 °C CMC 0,1 °C\n200 °C do 400 °C CMC 0,2 °C\nProcedura wewnętrzna; Wzorcowanie i pomiar. Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 206 w oparciu o EURAMET cg-20 v. 5.0 Komory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,05 °C\n100 °C do 200 °C CMC 0,1 °C\n200 °C do 400 °C CMC 0,2 °C\nProcedura wewnetrzna; Wzorcowanie i pomiar. Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 206 w oparciu o EURAMET cg-20 v. 5.0","search_en":"Thermostatic chambers Calibration — Temperature (electrical thermometry) Internal procedure; Calibration and measurement. Indirect method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Calibration and measurement. Indirect method At permanent location (S) Internal procedure PT 206 based on EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":60,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 206 based on EURAMET cg-20 v. 5.0","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C bis 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C bis 400 °C","cmc":"0,2 °C"}],"reference_de":"Internes Verfahren PT 206 auf Grundlage von EURAMET cg-20 v. 5.0","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Thermostatkammern Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Kalibrierung und Messung. Indirektes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Kalibrierung und Messung. Indirektes Verfahren Am festen Standort (S) Internes Verfahren PT 206 auf Grundlage von EURAMET cg-20 v. 5.0","technique_de":"Internes Verfahren; Kalibrierung und Messung. Indirektes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Kalibrierung und Messung. Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Thermostatkammern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"0,2 °C"}],"reference_zh":"内部程序 PT 206 依据EURAMET cg-20 v. 5.0","regulatory_area_zh":"温度（电测温）","search_zh":"恒温箱 校准 — 温度（电测温） 内部程序；校准和测量。间接法；在固定地点 (S) 温度（电测温） 内部程序 校准和测量。间接法 在固定地点 (S) 内部程序 PT 206 依据EURAMET cg-20 v. 5.0","technique_zh":"内部程序；校准和测量。间接法；在固定地点 (S)","techniques_zh":["内部程序","校准和测量。间接法","在固定地点 (S)"],"test_object_zh":"恒温箱","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C do 400 °C","cmc":"0,2 °C"}],"reference_cs":"Vnitřní postup PT 206 na základě EURAMET cg-20 v. 5.0","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Termostatické komory Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Kalibrace a měření. Nepřímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Kalibrace a měření. Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 206 na základě EURAMET cg-20 v. 5.0","technique_cs":"Vnitřní postup; Kalibrace a měření. Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Kalibrace a měření. Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Termostatické komory"},{"_id":"c3cc9f4a7f2addf651795de6","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Komory termostatyczne","test_object_en":"Thermostatic chambers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C do 400 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C to 400 °C","cmc":"0,2 °C"}],"technique":"Procedura wewnętrzna; Wzorcowanie i pomiar. Metoda pośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Calibration and measurement. Indirect method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Wzorcowanie i pomiar. Metoda pośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Calibration and measurement. Indirect method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,05 °C\n100 °C do 200 °C CMC 0,1 °C\n200 °C do 400 °C CMC 0,2 °C\nProcedura wewnętrzna; Wzorcowanie i pomiar. Metoda pośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 206 w oparciu o EURAMET cg-20 v. 5.0","norm_bases":["PT 206","EURAMET cg-20 v. 5.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Komory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,05 °C\n100 °C do 200 °C CMC 0,1 °C\n200 °C do 400 °C CMC 0,2 °C\nProcedura wewnętrzna; Wzorcowanie i pomiar. Metoda pośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 206 w oparciu o EURAMET cg-20 v. 5.0 Komory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,05 °C\n100 °C do 200 °C CMC 0,1 °C\n200 °C do 400 °C CMC 0,2 °C\nProcedura wewnetrzna; Wzorcowanie i pomiar. Metoda posrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 206 w oparciu o EURAMET cg-20 v. 5.0","search_en":"Thermostatic chambers Calibration — Temperature (electrical thermometry) Internal procedure; Calibration and measurement. Indirect method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Calibration and measurement. Indirect method Outside of permanent location (P) Internal procedure PT 206 based on EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":61,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 206 based on EURAMET cg-20 v. 5.0","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C bis 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C bis 400 °C","cmc":"0,2 °C"}],"reference_de":"Internes Verfahren PT 206 auf Grundlage von EURAMET cg-20 v. 5.0","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Thermostatkammern Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Kalibrierung und Messung. Indirektes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Kalibrierung und Messung. Indirektes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 206 auf Grundlage von EURAMET cg-20 v. 5.0","technique_de":"Internes Verfahren; Kalibrierung und Messung. Indirektes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Kalibrierung und Messung. Indirektes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Thermostatkammern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"0,2 °C"}],"reference_zh":"内部程序 PT 206 依据EURAMET cg-20 v. 5.0","regulatory_area_zh":"温度（电测温）","search_zh":"恒温箱 校准 — 温度（电测温） 内部程序；校准和测量。间接法；固定地点以外 (P) 温度（电测温） 内部程序 校准和测量。间接法 固定地点以外 (P) 内部程序 PT 206 依据EURAMET cg-20 v. 5.0","technique_zh":"内部程序；校准和测量。间接法；固定地点以外 (P)","techniques_zh":["内部程序","校准和测量。间接法","固定地点以外 (P)"],"test_object_zh":"恒温箱","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C do 400 °C","cmc":"0,2 °C"}],"reference_cs":"Vnitřní postup PT 206 na základě EURAMET cg-20 v. 5.0","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Termostatické komory Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Kalibrace a měření. Nepřímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Kalibrace a měření. Nepřímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 206 na základě EURAMET cg-20 v. 5.0","technique_cs":"Vnitřní postup; Kalibrace a měření. Nepřímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Kalibrace a měření. Nepřímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Termostatické komory"},{"_id":"181f1f863b459b33a5bd54a0","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Komory do sterylizacji parowej (np. autoklawy)","test_object_en":"Steam sterilisation chambers (e.g. autoclaves)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"0 °C do 200 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"","range":"0 °C to 200 °C","cmc":"0,2 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n0 °C do 200 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 206","norm_bases":["PT 206"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Komory do sterylizacji parowej (np. autoklawy) Wzorcowanie — Temperatura (termometria elektryczna)\n0 °C do 200 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 206 Komory do sterylizacji parowej (np. autoklawy) Wzorcowanie — Temperatura (termometria elektryczna)\n0 °C do 200 °C CMC 0,2 °C\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 206","search_en":"Steam sterilisation chambers (e.g. autoclaves) Calibration — Temperature (electrical thermometry) Internal procedure; Indirect method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Indirect method At permanent location (S) Internal procedure PT 206","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":62,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 206","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"0 °C to 200 °C","cmc":"0,2 °C"}],"reference_de":"Internes Verfahren PT 206","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Dampfsterilisationskammern (z. B. Autoklaven) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Indirektes Verfahren Am festen Standort (S) Internes Verfahren PT 206","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Dampfsterilisationskammern (z. B. Autoklaven)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"0 °C to 200 °C","cmc":"0,2 °C"}],"reference_zh":"内部程序 PT 206","regulatory_area_zh":"温度（电测温）","search_zh":"蒸汽灭菌室（如高压灭菌器） 校准 — 温度（电测温） 内部程序；间接方法；固定地点（S） 温度（电测温） 内部程序 间接法 在固定地点 (S) 内部程序 PT 206","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"蒸汽灭菌室（如高压灭菌器）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"0 °C to 200 °C","cmc":"0,2 °C"}],"reference_cs":"Vnitřní postup PT 206","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Komory pro parní sterilizaci (např. autoklávy) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 206","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Komory pro parní sterilizaci (např. autoklávy)"},{"_id":"bf2be899ecb07c9352832ce3","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Komory do sterylizacji parowej (np. autoklawy)","test_object_en":"Steam sterilisation chambers (e.g. autoclaves)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"0 °C do 200 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"","range":"0 °C to 200 °C","cmc":"0,2 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Indirect method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda pośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Indirect method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n0 °C do 200 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 206","norm_bases":["PT 206"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Komory do sterylizacji parowej (np. autoklawy) Wzorcowanie — Temperatura (termometria elektryczna)\n0 °C do 200 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 206 Komory do sterylizacji parowej (np. autoklawy) Wzorcowanie — Temperatura (termometria elektryczna)\n0 °C do 200 °C CMC 0,2 °C\nProcedura wewnetrzna; Metoda posrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 206","search_en":"Steam sterilisation chambers (e.g. autoclaves) Calibration — Temperature (electrical thermometry) Internal procedure; Indirect method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Indirect method Outside of permanent location (P) Internal procedure PT 206","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":63,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 206","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"0 °C to 200 °C","cmc":"0,2 °C"}],"reference_de":"Internes Verfahren PT 206","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Dampfsterilisationskammern (z. B. Autoklaven) Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Indirektes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 206","technique_de":"Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Dampfsterilisationskammern (z. B. Autoklaven)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"0 °C to 200 °C","cmc":"0,2 °C"}],"reference_zh":"内部程序 PT 206","regulatory_area_zh":"温度（电测温）","search_zh":"蒸汽灭菌室（如高压灭菌器） 校准 — 温度（电测温） 内部程序；间接法；固定地点以外 (P) 温度（电测温） 内部程序 间接法 固定地点以外 (P) 内部程序 PT 206","technique_zh":"内部程序；间接法；固定地点以外 (P)","techniques_zh":["内部程序","间接法","固定地点以外 (P)"],"test_object_zh":"蒸汽灭菌室（如高压灭菌器）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"0 °C to 200 °C","cmc":"0,2 °C"}],"reference_cs":"Vnitřní postup PT 206","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Komory pro parní sterilizaci (např. autoklávy) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Nepřímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 206","technique_cs":"Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Komory pro parní sterilizaci (např. autoklávy)"},{"_id":"6626f9cd2120fadb85defa14","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Komory klimatyczne","test_object_en":"Climatic chambers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C do 400 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C to 400 °C","cmc":"0,2 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,05 °C\n100 °C do 200 °C CMC 0,1 °C\n200 °C do 400 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 206 w oparciu o EURAMET cg-20 v. 5.0","norm_bases":["PT 206","EURAMET cg-20 v. 5.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Komory klimatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,05 °C\n100 °C do 200 °C CMC 0,1 °C\n200 °C do 400 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 206 w oparciu o EURAMET cg-20 v. 5.0 Komory klimatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,05 °C\n100 °C do 200 °C CMC 0,1 °C\n200 °C do 400 °C CMC 0,2 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 206 w oparciu o EURAMET cg-20 v. 5.0","search_en":"Climatic chambers Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) Internal procedure PT 206 based on EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":64,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 206 based on EURAMET cg-20 v. 5.0","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C bis 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C bis 400 °C","cmc":"0,2 °C"}],"reference_de":"Internes Verfahren PT 206 auf Grundlage von EURAMET cg-20 v. 5.0","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Klimakammern Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PT 206 auf Grundlage von EURAMET cg-20 v. 5.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Klimakammern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"0,2 °C"}],"reference_zh":"内部程序 PT 206 依据EURAMET cg-20 v. 5.0","regulatory_area_zh":"温度（电测温）","search_zh":"气候箱 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 温度（电测温） 内部程序 直接法 在固定地点 (S) 内部程序 PT 206 依据EURAMET cg-20 v. 5.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"气候箱","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C do 400 °C","cmc":"0,2 °C"}],"reference_cs":"Vnitřní postup PT 206 na základě EURAMET cg-20 v. 5.0","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Klimatické komory Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 206 na základě EURAMET cg-20 v. 5.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Klimatické komory"},{"_id":"5603afc9b9d99bf98d521547","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Komory klimatyczne","test_object_en":"Climatic chambers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C do 400 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C to 400 °C","cmc":"0,2 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,05 °C\n100 °C do 200 °C CMC 0,1 °C\n200 °C do 400 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 206 w oparciu o EURAMET cg-20 v. 5.0","norm_bases":["PT 206","EURAMET cg-20 v. 5.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Komory klimatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,05 °C\n100 °C do 200 °C CMC 0,1 °C\n200 °C do 400 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 206 w oparciu o EURAMET cg-20 v. 5.0 Komory klimatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 100 °C CMC 0,05 °C\n100 °C do 200 °C CMC 0,1 °C\n200 °C do 400 °C CMC 0,2 °C\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 206 w oparciu o EURAMET cg-20 v. 5.0","search_en":"Climatic chambers Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Direct method Outside of permanent location (P) Internal procedure PT 206 based on EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":65,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 206 based on EURAMET cg-20 v. 5.0","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C bis 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C bis 400 °C","cmc":"0,2 °C"}],"reference_de":"Internes Verfahren PT 206 auf Grundlage von EURAMET cg-20 v. 5.0","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Klimakammern Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 206 auf Grundlage von EURAMET cg-20 v. 5.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Klimakammern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"0,2 °C"}],"reference_zh":"内部程序 PT 206 依据EURAMET cg-20 v. 5.0","regulatory_area_zh":"温度（电测温）","search_zh":"气候箱 校准 — 温度（电测温） 内部程序；直接法；固定地点以外 (P) 温度（电测温） 内部程序 直接法 固定地点以外 (P) 内部程序 PT 206 依据EURAMET cg-20 v. 5.0","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"气候箱","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"0,1 °C"},{"name":"","range":"200 °C do 400 °C","cmc":"0,2 °C"}],"reference_cs":"Vnitřní postup PT 206 na základě EURAMET cg-20 v. 5.0","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Klimatické komory Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 206 na základě EURAMET cg-20 v. 5.0","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Klimatické komory"},{"_id":"6fc5bc7c84f9f4924141d7da","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kalibratory temperatury","test_object_en":"Temperature calibrators","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-100 °C do 150 °C","cmc":"0,02 °C"},{"name":"","range":"150 °C do 420 °C","cmc":"0,03 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,07 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"-100 °C do 150 °C","cmc":"0,02 °C"},{"name":"","range":"150 °C do 420 °C","cmc":"0,03 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,07 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,2 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 150 °C CMC 0,02 °C\n150 °C do 420 °C CMC 0,03 °C\n420 °C do 650 °C CMC 0,07 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 206 w oparciu o EURAMET cg-13 v. 4.0","norm_bases":["PT 206","EURAMET cg-13 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Kalibratory temperatury Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 150 °C CMC 0,02 °C\n150 °C do 420 °C CMC 0,03 °C\n420 °C do 650 °C CMC 0,07 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 206 w oparciu o EURAMET cg-13 v. 4.0 Kalibratory temperatury Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 150 °C CMC 0,02 °C\n150 °C do 420 °C CMC 0,03 °C\n420 °C do 650 °C CMC 0,07 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 206 w oparciu o EURAMET cg-13 v. 4.0","search_en":"Temperature calibrators Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) Internal procedure PT 206 based on EURAMET cg-13 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":66,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 206 based on EURAMET cg-13 v. 4.0","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C do 150 °C","cmc":"0,02 °C"},{"name":"","range":"150 °C do 420 °C","cmc":"0,03 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,07 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,2 °C"}],"reference_de":"Internes Verfahren PT 206 auf Grundlage von EURAMET cg-13 v. 4.0","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Temperaturkalibratoren Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PT 206 auf Grundlage von EURAMET cg-13 v. 4.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Temperaturkalibratoren","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C do 150 °C","cmc":"0,02 °C"},{"name":"","range":"150 °C do 420 °C","cmc":"0,03 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,07 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,2 °C"}],"reference_zh":"内部程序 PT 206 依据EURAMET cg-13 v. 4.0","regulatory_area_zh":"温度（电测温）","search_zh":"温度校准器 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 温度（电测温） 内部程序 直接法 在固定地点 (S) 内部程序 PT 206 依据EURAMET cg-13 v. 4.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"温度校准器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C do 150 °C","cmc":"0,02 °C"},{"name":"","range":"150 °C do 420 °C","cmc":"0,03 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,07 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"reference_cs":"Vnitřní postup PT 206 na základě EURAMET cg-13 v. 4.0","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Kalibrátory teploty Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 206 na základě EURAMET cg-13 v. 4.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory teploty"},{"_id":"7da532d579efc2f69ea859ed","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kalibratory temperatury","test_object_en":"Temperature calibrators","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-100 °C do 420 °C","cmc":"0,1 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"-100 °C do 420 °C","cmc":"0,1 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,2 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 420 °C CMC 0,1 °C\n420 °C do 650 °C CMC 0,2 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 206 w oparciu o EURAMET cg-13 v. 4.0","norm_bases":["PT 206","EURAMET cg-13 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Kalibratory temperatury Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 420 °C CMC 0,1 °C\n420 °C do 650 °C CMC 0,2 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 206 w oparciu o EURAMET cg-13 v. 4.0 Kalibratory temperatury Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do 420 °C CMC 0,1 °C\n420 °C do 650 °C CMC 0,2 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 206 w oparciu o EURAMET cg-13 v. 4.0","search_en":"Temperature calibrators Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Direct method Outside of permanent location (P) Internal procedure PT 206 based on EURAMET cg-13 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":67,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 206 based on EURAMET cg-13 v. 4.0","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C do 420 °C","cmc":"0,1 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,2 °C"}],"reference_de":"Internes Verfahren PT 206 auf Grundlage von EURAMET cg-13 v. 4.0","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Temperaturkalibratoren Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 206 auf Grundlage von EURAMET cg-13 v. 4.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Temperaturkalibratoren","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C do 420 °C","cmc":"0,1 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,2 °C"}],"reference_zh":"内部程序 PT 206 依据EURAMET cg-13 v. 4.0","regulatory_area_zh":"温度（电测温）","search_zh":"温度校准器 校准 — 温度（电测温） 内部程序；直接法；固定地点以外 (P) 温度（电测温） 内部程序 直接法 固定地点以外 (P) 内部程序 PT 206 依据EURAMET cg-13 v. 4.0","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"温度校准器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C do 420 °C","cmc":"0,1 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"reference_cs":"Vnitřní postup PT 206 na základě EURAMET cg-13 v. 4.0","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Kalibrátory teploty Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 206 na základě EURAMET cg-13 v. 4.0","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Kalibrátory teploty"},{"_id":"435af8544a4f44c39339f16c","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Piece","test_object_en":"Furnaces","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"0 °C do 420 °C","cmc":"0,03 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,07 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"0 °C do 420 °C","cmc":"0,03 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,07 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,2 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n0 °C do 420 °C CMC 0,03 °C\n420 °C do 650 °C CMC 0,07 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 206","norm_bases":["PT 206"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Piece Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n0 °C do 420 °C CMC 0,03 °C\n420 °C do 650 °C CMC 0,07 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 206 Piece Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n0 °C do 420 °C CMC 0,03 °C\n420 °C do 650 °C CMC 0,07 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 206","search_en":"Furnaces Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) Internal procedure PT 206","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":68,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 206","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"0 °C do 420 °C","cmc":"0,03 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,07 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,2 °C"}],"reference_de":"Internes Verfahren PT 206","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Öfen Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PT 206","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Öfen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"0 °C do 420 °C","cmc":"0,03 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,07 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,2 °C"}],"reference_zh":"内部程序 PT 206","regulatory_area_zh":"温度（电测温）","search_zh":"炉具 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 温度（电测温） 内部程序 直接法 在固定地点 (S) 内部程序 PT 206","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"炉具","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"0 °C do 420 °C","cmc":"0,03 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,07 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"reference_cs":"Vnitřní postup PT 206","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Pece Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 206","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Pece"},{"_id":"e555936aca3bd18834e6ed37","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Piece","test_object_en":"Furnaces","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"0 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"0 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,2 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n0 °C do 650 °C CMC 0,2 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 206","norm_bases":["PT 206"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":"Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"The CMC uncertainty value refers to a single measurement point in the space of the equipment","search_text":"Piece Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n0 °C do 650 °C CMC 0,2 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 206 Piece Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n0 °C do 650 °C CMC 0,2 °C\n650 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,2 °C\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 206","search_en":"Furnaces Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Direct method Outside of permanent location (P) Internal procedure PT 206","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":69,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 206","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"0 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,2 °C"}],"reference_de":"Internes Verfahren PT 206","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Öfen Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 206","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Öfen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"0 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,2 °C"}],"reference_zh":"内部程序 PT 206","regulatory_area_zh":"温度（电测温）","search_zh":"炉具 校准 — 温度（电测温） 内部程序；直接法；固定地点以外 (P) 温度（电测温） 内部程序 直接法 固定地点以外 (P) 内部程序 PT 206","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"炉具","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"0 °C do 650 °C","cmc":"0,2 °C"},{"name":"","range":"650 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,2 °C"}],"reference_cs":"Vnitřní postup PT 206","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Pece Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 206","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Pece"},{"_id":"4201e53516c269c27ad10cb3","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Termometry wskazówkowe (manometryczne i bimetalowe)","test_object_en":"Dial thermometers (pressure-spring and bimetallic)","methodology":"Wzorcowanie — Temperatura (termometria nieelektryczna)","methodology_en":"Calibration — Temperature (non-electrical thermometry)","parameters":[{"name":"","range":"0 °C do 120 °C","cmc":"0,1 °C"}],"parameters_en":[{"name":"","range":"0 °C to 120 °C","cmc":"0,1 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria nieelektryczna)\n0 °C do 120 °C CMC 0,1 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 204","norm_bases":["PT 204"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria nieelektryczna)","regulatory_area_en":"Temperature (non-electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry wskazówkowe (manometryczne i bimetalowe) Wzorcowanie — Temperatura (termometria nieelektryczna)\n0 °C do 120 °C CMC 0,1 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PT 204 Termometry wskazowkowe (manometryczne i bimetalowe) Wzorcowanie — Temperatura (termometria nieelektryczna)\n0 °C do 120 °C CMC 0,1 °C\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PT 204","search_en":"Dial thermometers (pressure-spring and bimetallic) Calibration — Temperature (non-electrical thermometry) Internal procedure; Indirect method; At permanent location (S) Temperature (non-electrical thermometry) Internal procedure Indirect method At permanent location (S) Internal procedure PT 204","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":70,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 204","methodology_de":"Kalibrierung — Temperatur (nichtelektrische Thermometrie)","parameters_de":[{"name":"","range":"0 °C bis 120 °C","cmc":"0,1 °C"}],"reference_de":"Internes Verfahren PT 204","regulatory_area_de":"Temperatur (nichtelektrische Thermometrie)","search_de":"Zeigerthermometer (Feder- und Bimetallthermometer) Kalibrierung — Temperatur (nichtelektrische Thermometrie) Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Temperatur (nichtelektrische Thermometrie) Internes Verfahren Indirektes Verfahren Am festen Standort (S) Internes Verfahren PT 204","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Zeigerthermometer (Feder- und Bimetallthermometer)","methodology_zh":"校准 — 温度（非电测温）","parameters_zh":[{"name":"","range":"0 °C 至 120 °C","cmc":"0,1 °C"}],"reference_zh":"内部程序 PT 204","regulatory_area_zh":"温度（非电测温）","search_zh":"指针式温度计（压力式和双金属） 校准 — 温度（非电测温） 内部程序；间接方法；固定地点（S） 温度（非电测温） 内部程序 间接法 在固定地点 (S) 内部程序 PT 204","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"指针式温度计（压力式和双金属）","methodology_cs":"Kalibrace — Teplota (neelektrická termometrie)","parameters_cs":[{"name":"","range":"0 °C do 120 °C","cmc":"0,1 °C"}],"reference_cs":"Vnitřní postup PT 204","regulatory_area_cs":"Teplota (neelektrická termometrie)","search_cs":"Ručkové teploměry (tlakové a bimetalové) Kalibrace — Teplota (neelektrická termometrie) Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Teplota (neelektrická termometrie) Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PT 204","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Ručkové teploměry (tlakové a bimetalové)"},{"_id":"5a7afcd98c787d7c8f4de675","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Termometry wskazówkowe (manometryczne i bimetalowe)","test_object_en":"Dial thermometers (pressure-spring and bimetallic)","methodology":"Wzorcowanie — Temperatura (termometria nieelektryczna)","methodology_en":"Calibration — Temperature (non-electrical thermometry)","parameters":[{"name":"","range":"0 °C do 120 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"","range":"0 °C to 120 °C","cmc":"0,2 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Indirect method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda pośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Indirect method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria nieelektryczna)\n0 °C do 120 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P)","reference":"Procedura wewnętrzna PT 204","norm_bases":["PT 204"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria nieelektryczna)","regulatory_area_en":"Temperature (non-electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Termometry wskazówkowe (manometryczne i bimetalowe) Wzorcowanie — Temperatura (termometria nieelektryczna)\n0 °C do 120 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda pośrednia; Poza stałą lokalizacją (P) Procedura wewnętrzna PT 204 Termometry wskazowkowe (manometryczne i bimetalowe) Wzorcowanie — Temperatura (termometria nieelektryczna)\n0 °C do 120 °C CMC 0,2 °C\nProcedura wewnetrzna; Metoda posrednia; Poza stala lokalizacja (P) Procedura wewnetrzna PT 204","search_en":"Dial thermometers (pressure-spring and bimetallic) Calibration — Temperature (non-electrical thermometry) Internal procedure; Indirect method; Outside of permanent location (P) Temperature (non-electrical thermometry) Internal procedure Indirect method Outside of permanent location (P) Internal procedure PT 204","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":71,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 204","methodology_de":"Kalibrierung — Temperatur (nichtelektrische Thermometrie)","parameters_de":[{"name":"","range":"0 °C bis 120 °C","cmc":"0,2 °C"}],"reference_de":"Internes Verfahren PT 204","regulatory_area_de":"Temperatur (nichtelektrische Thermometrie)","search_de":"Zeigerthermometer (Feder- und Bimetallthermometer) Kalibrierung — Temperatur (nichtelektrische Thermometrie) Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P) Temperatur (nichtelektrische Thermometrie) Internes Verfahren Indirektes Verfahren Außerhalb des festen Standorts (P) Internes Verfahren PT 204","technique_de":"Internes Verfahren; Indirektes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Zeigerthermometer (Feder- und Bimetallthermometer)","methodology_zh":"校准 — 温度（非电测温）","parameters_zh":[{"name":"","range":"0 °C 至 120 °C","cmc":"0,2 °C"}],"reference_zh":"内部程序 PT 204","regulatory_area_zh":"温度（非电测温）","search_zh":"指针式温度计（压力式和双金属） 校准 — 温度（非电测温） 内部程序；间接法；固定地点以外 (P) 温度（非电测温） 内部程序 间接法 固定地点以外 (P) 内部程序 PT 204","technique_zh":"内部程序；间接法；固定地点以外 (P)","techniques_zh":["内部程序","间接法","固定地点以外 (P)"],"test_object_zh":"指针式温度计（压力式和双金属）","methodology_cs":"Kalibrace — Teplota (neelektrická termometrie)","parameters_cs":[{"name":"","range":"0 °C do 120 °C","cmc":"0,2 °C"}],"reference_cs":"Vnitřní postup PT 204","regulatory_area_cs":"Teplota (neelektrická termometrie)","search_cs":"Ručkové teploměry (tlakové a bimetalové) Kalibrace — Teplota (neelektrická termometrie) Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P) Teplota (neelektrická termometrie) Vnitřní postup Nepřímá metoda Mimo stálou lokalitu (P) Vnitřní postup PT 204","technique_cs":"Vnitřní postup; Nepřímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Ručkové teploměry (tlakové a bimetalové)"},{"_id":"27de45df8208110a9cae26de","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Pirometry (w tym pirometry radiacyjne, fotoelektryczne, wielopasmowe, bezstykowe układy pomiaru temperatury)","test_object_en":"Pyrometers (including radiation, photoelectric and multiband pyrometers, non-contact temperature measuring systems)","methodology":"Wzorcowanie — Temperatura (termometria radiacyjna)","methodology_en":"Calibration — Temperature (radiation thermometry)","parameters":[{"name":"","range":"30 °C do 350 °C","cmc":"2,9 °C"}],"parameters_en":[{"name":"","range":"30 °C to 350 °C","cmc":"2,9 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria radiacyjna)\n30 °C do 350 °C CMC 2,9 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 205","norm_bases":["PT 205"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria radiacyjna)","regulatory_area_en":"Temperature (radiation thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pirometry (w tym pirometry radiacyjne, fotoelektryczne, wielopasmowe, bezstykowe układy pomiaru temperatury) Wzorcowanie — Temperatura (termometria radiacyjna)\n30 °C do 350 °C CMC 2,9 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PT 205 Pirometry (w tym pirometry radiacyjne, fotoelektryczne, wielopasmowe, bezstykowe uklady pomiaru temperatury) Wzorcowanie — Temperatura (termometria radiacyjna)\n30 °C do 350 °C CMC 2,9 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PT 205","search_en":"Pyrometers (including radiation, photoelectric and multiband pyrometers, non-contact temperature measuring systems) Calibration — Temperature (radiation thermometry) Internal procedure; At permanent location (S) Temperature (radiation thermometry) Internal procedure At permanent location (S) Internal procedure PT 205","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":72,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 205","methodology_de":"Kalibrierung — Temperatur (Strahlungsthermometrie)","parameters_de":[{"name":"","range":"30 °C to 350 °C","cmc":"2,9 °C"}],"reference_de":"Internes Verfahren PT 205","regulatory_area_de":"Temperatur (Strahlungsthermometrie)","search_de":"Pyrometer (einschließlich Strahlungs-, fotoelektrischer und Mehrband-Pyrometer, berührungsloser Temperaturmesssysteme) Kalibrierung — Temperatur (Strahlungsthermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (Strahlungsthermometrie) Internes Verfahren Am festen Standort (S) Internes Verfahren PT 205","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Pyrometer (einschließlich Strahlungs-, fotoelektrischer und Mehrband-Pyrometer, berührungsloser Temperaturmesssysteme)","methodology_zh":"校准 — 温度（辐射测温）","parameters_zh":[{"name":"","range":"30 °C to 350 °C","cmc":"2,9 °C"}],"reference_zh":"内部程序 PT 205","regulatory_area_zh":"温度（辐射测温）","search_zh":"高温计（包括辐射、光电、多波段高温计及非接触测温系统） 校准 — 温度（辐射测温） 内部程序；在固定地点 (S) 温度（辐射测温） 内部程序 在固定地点 (S) 内部程序 PT 205","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"高温计（包括辐射、光电、多波段高温计及非接触测温系统）","methodology_cs":"Kalibrace — Teplota (radiační termometrie)","parameters_cs":[{"name":"","range":"30 °C to 350 °C","cmc":"2,9 °C"}],"reference_cs":"Vnitřní postup PT 205","regulatory_area_cs":"Teplota (radiační termometrie)","search_cs":"Pyrometry (včetně radiačních, fotoelektrických a vícepásmových pyrometrů, bezkontaktních systémů měření teploty) Kalibrace — Teplota (radiační termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (radiační termometrie) Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PT 205","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Pyrometry (včetně radiačních, fotoelektrických a vícepásmových pyrometrů, bezkontaktních systémů měření teploty)"},{"_id":"b5afcfe338b12b98ef88cc9f","lab_id":"6afa3b988989a133b76445c3","country":"PL","accr_number":"AP 092","accr_body":"PCA","test_object":"Kamery termowizyjne\nSkanery liniowe","test_object_en":"Thermal imaging cameras\nLine scanners","methodology":"Wzorcowanie — Temperatura (termometria radiacyjna)","methodology_en":"Calibration — Temperature (radiation thermometry)","parameters":[{"name":"","range":"30 °C do 350 °C","cmc":"2,9 °C"}],"parameters_en":[{"name":"","range":"30 °C to 350 °C","cmc":"2,9 °C"}],"technique":"Procedura wewnętrzna; Wzorcowanie tylko w zakresie błędu pomiaru temperatury; W stałej lokalizacji (S)","technique_en":"Internal procedure; Calibration of the temperature measurement error only; At permanent location (S)","techniques":["Procedura wewnętrzna","Wzorcowanie tylko w zakresie błędu pomiaru temperatury","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Calibration of the temperature measurement error only","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria radiacyjna)\n30 °C do 350 °C CMC 2,9 °C\nProcedura wewnętrzna; Wzorcowanie tylko w zakresie błędu pomiaru temperatury; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PT 205","norm_bases":["PT 205"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria radiacyjna)","regulatory_area_en":"Temperature (radiation thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kamery termowizyjne\nSkanery liniowe Wzorcowanie — Temperatura (termometria radiacyjna)\n30 °C do 350 °C CMC 2,9 °C\nProcedura wewnętrzna; Wzorcowanie tylko w zakresie błędu pomiaru temperatury; W stałej lokalizacji (S) Procedura wewnętrzna PT 205 Kamery termowizyjne\nSkanery liniowe Wzorcowanie — Temperatura (termometria radiacyjna)\n30 °C do 350 °C CMC 2,9 °C\nProcedura wewnetrzna; Wzorcowanie tylko w zakresie bledu pomiaru temperatury; W stalej lokalizacji (S) Procedura wewnetrzna PT 205","search_en":"Thermal imaging cameras Line scanners Calibration — Temperature (radiation thermometry) Internal procedure; Calibration of the temperature measurement error only; At permanent location (S) Temperature (radiation thermometry) Internal procedure Calibration of the temperature measurement error only At permanent location (S) Internal procedure PT 205","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":73,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PT 205","methodology_de":"Kalibrierung — Temperatur (Strahlungsthermometrie)","parameters_de":[{"name":"","range":"30 °C to 350 °C","cmc":"2,9 °C"}],"reference_de":"Internes Verfahren PT 205","regulatory_area_de":"Temperatur (Strahlungsthermometrie)","search_de":"Wärmebildkameras Linienscanner Kalibrierung — Temperatur (Strahlungsthermometrie) Internes Verfahren; Kalibrierung nur hinsichtlich des Temperaturmessfehlers; Am festen Standort (S) Temperatur (Strahlungsthermometrie) Internes Verfahren Kalibrierung nur hinsichtlich des Temperaturmessfehlers Am festen Standort (S) Internes Verfahren PT 205","technique_de":"Internes Verfahren; Kalibrierung nur hinsichtlich des Temperaturmessfehlers; Am festen Standort (S)","techniques_de":["Internes Verfahren","Kalibrierung nur hinsichtlich des Temperaturmessfehlers","Am festen Standort (S)"],"test_object_de":"Wärmebildkameras\nLinienscanner","methodology_zh":"校准 — 温度（辐射测温）","parameters_zh":[{"name":"","range":"30 °C to 350 °C","cmc":"2,9 °C"}],"reference_zh":"内部程序 PT 205","regulatory_area_zh":"温度（辐射测温）","search_zh":"热像仪 线扫描仪 校准 — 温度（辐射测温） 内部程序；仅校准温度测量误差；在固定地点 (S) 温度（辐射测温） 内部程序 仅校准温度测量误差 在固定地点 (S) 内部程序 PT 205","technique_zh":"内部程序；仅校准温度测量误差；在固定地点 (S)","techniques_zh":["内部程序","仅校准温度测量误差","在固定地点 (S)"],"test_object_zh":"热像仪\n线扫描仪","methodology_cs":"Kalibrace — Teplota (radiační termometrie)","parameters_cs":[{"name":"","range":"30 °C to 350 °C","cmc":"2,9 °C"}],"reference_cs":"Vnitřní postup PT 205","regulatory_area_cs":"Teplota (radiační termometrie)","search_cs":"Termovizní kamery Řádkové skenery Kalibrace — Teplota (radiační termometrie) Vnitřní postup; Kalibrace pouze v rozsahu chyby měření teploty; Ve stálé lokalitě (S) Teplota (radiační termometrie) Vnitřní postup Kalibrace pouze v rozsahu chyby měření teploty Ve stálé lokalitě (S) Vnitřní postup PT 205","technique_cs":"Vnitřní postup; Kalibrace pouze v rozsahu chyby měření teploty; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Kalibrace pouze v rozsahu chyby měření teploty","Ve stálé lokalitě (S)"],"test_object_cs":"Termovizní kamery\nŘádkové skenery"}],"has_pdf":true}