🇵🇱 Energetyczne Systemy Pomiarowe Sp. z o. o. PL

PCA AP 090 • Białystok, Poland • 18 calibration items

Metrology & calibration

Energetyczne Systemy Pomiarowe Sp. z o. o. is a calibration laboratory accredited by PCA under number AP 090 (Białystok, Poland). Its accreditation scope covers 18 calibration items in the following areas: Metrology & calibration. Calibrated items include: Power quality meters, Power analysers, Digital voltmeters, Residual current device testers. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S), Internal procedure; Direct and indirect method; At permanent locati…, Internal procedure; Reference meter method; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 090
  • Calibration items in scope: 18
  • Types of calibrated items: 22
  • Calibration principles used: 5
  • City: Białystok, Poland
  • Valid until: 18-01-2030
Accreditation number
AP 090
Accreditation body
PCA
Address
ul. Elektryczna 13, 15-950 Białystok
City
Białystok, Poland
Division
Calibration Laboratory
Valid until
18-01-2030

What this laboratory calibrates (22)

Calibration principles (5)

Certificate information

Issue date
19.12.2025
Issue no.
18
Certificate date
31.12.2019
Accreditation cycle
19.12.2025 — 18.01.2030
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (18)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Digital voltmeters
Power quality meters
Power analysers
Oscilloscopes
Calibration — DC voltage
0,25 mV to 2,1 mV · CMC 5,4 · 10⁻⁵ · U + 0,0059 mV 2,1001 mV to 21 mV · CMC 3,7 · 10⁻⁵ · U + 0,0058 mV 21,0001 mV to 210 mV · CMC 1,2 · 10⁻⁴ · U + 0,0069 mV 0,210001 V to 2,1 V · CMC 6,0 · 10⁻⁵ · U + 0,000034 V 2,10001 V to 21 V · CMC 3,6 · 10⁻⁵ · U + 0,00034 V 21,0001 V to 210 V · CMC 6,0 · 10⁻⁵ · U + 0,0023 V 210,001 V to 1050 V · CMC 1,4 · 10⁻⁴ · U + 0,0058 V
DC voltage
Internal procedure; Direct method; At permanent location (S) PW-02 based on EURAMET cg-15 v.3.0
2 Digital voltmeters Calibration — DC voltage
1,5 mV to 10 mV · CMC 4,6 µV 10 mV to 50 mV · CMC 6,9 µV 50 mV to 500 mV · CMC 0,01 %
DC voltage
Internal procedure; Direct method; At permanent location (S) PW-09
3 Digital ammeters Calibration — DC current
0,25 mA to 2,1 mA · CMC 2,3 · 10⁻⁴ · I + 0,00022 mA 2,1001 mA to 21 mA · CMC 1,4 · 10⁻⁴ · I + 0,0012 mA 21,0001 mA to 210 mA · CMC 2,1 · 10⁻⁴ · I + 0,010 mA 0,210001 A to 2,1 A · CMC 9,6 · 10⁻⁴ · I + 0,00011 A 2,10001 A to 21 A · CMC 2,3 · 10⁻³ · I + 0,0046 A
DC current
Internal procedure; Direct and indirect method; At permanent location (S) PW-02 based on EURAMET cg-15 v.3.0
4 Clamp meters Calibration — DC current
1 A to 10 A · CMC 0,1 A 10 A to 1000 A · CMC 0,60 %
DC current
Internal procedure; Direct and indirect method; At permanent location (S) PW-02 based on EURAMET cg-15 v.3.0
5 Digital voltmeters
Power quality meters
Residual current device testers
Power analysers
Oscilloscopes
Calibration — AC voltage
frequency 50 Hz — 1 mV to 2,1 mV · CMC 9,1 · 10⁻⁴ · U + 0,047 mV frequency 50 Hz — 2,101 mV to 21 mV · CMC 5,8 · 10⁻⁴ · U + 0,036 mV frequency 50 Hz — 21,001 mV to 210 mV · CMC 6,1 · 10⁻⁴ · U + 0,046 mV frequency 50 Hz — 0,21001 V to 2,1 V · CMC 6,2 · 10⁻⁴ · U + 0,00018 V frequency 50 Hz — 2,1001 V to 21 V · CMC 9,6 · 10⁻⁴ · U + 0,0018 V frequency 50 Hz — 21,001 V to 210 V · CMC 6,1 · 10⁻⁴ · U + 0,034 V frequency 50 Hz — 210,001 V to 1050 V · CMC 9,2 · 10⁻⁴ · U + 0,096 V
AC voltage
Internal procedure; Direct method; At permanent location (S) PW-02 based on EURAMET cg-15 v.3.0
6 Digital ammeters
Power quality meters
Power analysers
Calibration — AC current
frequency 50 Hz — 0,25 mA to 2,1 mA · CMC 1,2 · 10⁻³ · I + 0,0023 mA frequency 50 Hz — 2,101 mA to 21 mA · CMC 1,2 · 10⁻³ · I + 0,011 mA frequency 50 Hz — 21,001 mA to 210 mA · CMC 1,2 · 10⁻³ · I + 0,11 mA frequency 50 Hz — 0,21001 A to 2,1 A · CMC 2,9 · 10⁻³ · I + 0,00069 A frequency 50 Hz — 2,1001 A to 21 A · CMC 2,9 · 10⁻³ · I + 0,018 A
AC current
Internal procedure; Direct method; At permanent location (S) PW-02 based on EURAMET cg-15 v.3.0
7 Clamp meters
Power quality meters
Power analysers
Calibration — AC current
frequency 50 Hz — 1 A to 1000 A · CMC 0,60 %
AC current
Internal procedure; Direct and indirect method; At permanent location (S) PW-02 based on EURAMET cg-15 v.3.0
8 Power quality meters
Residual current device testers
Calibration — AC current
frequency 50 Hz — 5 mA to 30 mA · CMC 3,0 % frequency 50 Hz — 30 mA to 500 mA · CMC 2,5 %
AC current
Internal procedure; Direct method; At permanent location (S) PW-07
9 Power quality meters
Earth resistance meters
Insulation resistance meters
Digital ohmmeters
Multimeters
Calibration — DC resistance
0,001 Ω · CMC 0,10 % 0,01 Ω · CMC 0,10 % 0,1 Ω · CMC 0,024 % 1 Ω · CMC 0,024 % 10 Ω · CMC 0,024 % 0,1 Ω to 1 Ω · CMC 0,24 % 1 Ω to 1000 Ω · CMC 0,058 % 10 kΩ to 1000 kΩ · CMC 0,35 % 1 MΩ to 10 MΩ · CMC 0,35 % 10 MΩ to 1000 MΩ · CMC 1,2 % 1 GΩ to 10 GΩ · CMC 1,8 % 10 GΩ to 100 GΩ · CMC 2,1 %
DC resistance
Internal procedure; Direct method; At permanent location (S) PW-05
10 Power quality meters
Fault loop resistance meters
Calibration — AC resistance
frequency 50 Hz — 0,06 Ω to 1 Ω · CMC 0,040 Ω frequency 50 Hz — 1 Ω to 5 Ω · CMC 0,045 Ω frequency 50 Hz — 5 Ω to 10 Ω · CMC 0,050 Ω frequency 50 Hz — 10 Ω to 50 Ω · CMC 0,50 % frequency 50 Hz — 50 Ω to 200 Ω · CMC 0,40 %
AC resistance
Internal procedure; Direct method; At permanent location (S) PW-04
11 Power quality meters
Fault loop impedance meters
Calibration — Impedance
frequency 50 Hz — 0,07 Ω to 1 Ω · CMC 0,040 Ω frequency 50 Hz — 1 Ω to 5 Ω · CMC 0,045 Ω frequency 50 Hz — 5 Ω to 10 Ω · CMC 0,050 Ω frequency 50 Hz — 10 Ω to 50 Ω · CMC 0,50 % frequency 50 Hz — 50 Ω to 200 Ω · CMC 0,40 %
Impedance
Internal procedure; Direct and indirect method; At permanent location (S) PW-04
12 Power analysers
AC active electrical energy meters
Calibration — Energy
frequency 50 Hz; voltage: 58 V to 300 V; current: 0,05 A to 120 A; cos φ: 1 · CMC 0,062 % frequency 50 Hz; voltage: 58 V to 300 V; current: 0,05 A to 120 A; cos φ: 0,5 ind. · CMC 0,13 % frequency 50 Hz; voltage: 58 V to 300 V; current: 0,05 A to 120 A; cos φ: 0,5 poj. · CMC 0,13 %
Energy
Internal procedure; Reference meter method; At permanent location (S) PW-01
13 Power analysers
AC reactive electrical energy meters
Calibration — Energy
frequency 50 Hz; voltage: 58 V to 300 V; current: 0,05 A to 120 A; sin φ: 1 · CMC 0,16 % frequency 50 Hz; voltage: 58 V to 300 V; current: 0,05 A to 120 A; sin φ: 0,5 ind. · CMC 0,32 % frequency 50 Hz; voltage: 58 V to 300 V; current: 0,05 A to 120 A; sin φ: 0,5 poj. · CMC 0,32 %
Energy
Internal procedure; Reference meter method; At permanent location (S) PW-01
14 DC electrical energy meters Calibration — Energy
voltage: 2000 V to 4000 V; time: 0,08 h to 1 h; current (up to 5000 A) depending on the voltage applied to the current circuit: 1,5 mV to 5 mV · CMC 0,35 % voltage: 2000 V to 4000 V; time: 0,08 h to 1 h; current (up to 5000 A) depending on the voltage applied to the current circuit: 5 mV to 500 mV · CMC 0,21 %
Energy
Internal procedure; Power and time method; At permanent location (S) PW-09
15 Breakdown testers
DC and AC voltage sources
Voltmeters
Calibration — High voltage and current
DC and AC voltage (at 50 Hz) — 0,5 kV to 2 kV · CMC 0,05 kV DC and AC voltage (at 50 Hz) — 2 kV to 4 kV · CMC 0,06 kV DC and AC voltage (at 50 Hz) — 4 kV to 5 kV · CMC 0,08 kV
High voltage and current
Internal procedure; Direct method; At permanent location (S) PW-08
16 Kilovoltmeters
Voltmeters
Calibration — High voltage and current
2 kV to 4 kV · CMC 0,2 %
High voltage and current
Internal procedure; Direct method; At permanent location (S) PW-09
17 Power quality meters
Residual current device testers
Calibration — Time (time interval)
20 ms to 400 ms · CMC 2 ms 400 ms to 500 ms · CMC 8,2 ms
Time (time interval)
Internal procedure; Direct method; At permanent location (S) PW-07
18 Torque wrenches
Torque screwdrivers
Calibration — Torque
0,2 Nm to 1 Nm · CMC 1,5 % 1 Nm to 1000 Nm · CMC 1%
Torque
Internal procedure; At permanent location (S) PW-11

Reference standards (9)

EURAMET cg-15 v.3.0
PW-01
PW-02
PW-04
PW-05
PW-07
PW-08
PW-09
PW-11

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20090