Okręgowy Urząd Miar w Szczecinie is a calibration laboratory accredited by PCA under number AP 089 (Szczecin, Poland). Its accreditation scope covers 35 calibration items in the following areas: Metrology & calibration. Calibrated items include: Power quality meters, Multimeters, Calibrators, Power supplies. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S), Internal procedure; At permanent location (S), Internal procedure; At permanent location (S) and outside of it (P).

At a glance

  • Accreditation number: PCA AP 089
  • Calibration items in scope: 35
  • Types of calibrated items: 48
  • Calibration principles used: 6
  • City: Szczecin, Poland
  • Valid until: 18-01-2030
Accreditation number
AP 089
Accreditation body
PCA
Address
plac Lotników 4/5, 70-414 Szczecin
City
Szczecin, Poland
Division
Calibration Laboratories Group
Valid until
18-01-2030

What this laboratory calibrates (48)

Calibration principles (6)

Certificate information

Issue date
18.12.2025
Issue no.
18
Certificate date
29.11.2019
Accreditation cycle
18.12.2025 — 18.01.2030
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (35)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 pH meters Calibration — pH
- pH — 0 to 14 · CMC 0,003 - DC voltage — -2000 mV to 2000 mV · CMC 0,2 mV
pH
Internal procedure; Electrical method; At permanent location (S) Internal procedure IWN-F-02
2 Conductivity meters Calibration — Electrolytic conductivity (conductometry)
0,0002 mS/cm to 0,02 mS/cm · CMC 0,000001 mS/cm 0,02 mS/cm to 2,0 mS/cm · CMC 0,06 % 2,0 mS/cm to 200 mS/cm · CMC 0,18 %
Electrolytic conductivity (conductometry)
Internal procedure; Electrical method; At permanent location (S) Internal procedure IWN-F-01
3 Analogue dial gauges with a scale interval ≥ 0,01 mm Calibration — Length
0 mm to 50 mm · CMC 5,0 µm
Length
Internal procedure; At permanent location (S) Internal procedure IWN-L-04
4 Digital dial gauges with a resolution ≥ 0,001 mm Calibration — Length
0 mm to 50 mm · CMC 2,1 µm
Length
Internal procedure; At permanent location (S) Internal procedure IWN-L-04
5 External micrometers Calibration — Length
0 mm to 500 mm · CMC (0,70 + 0,02 ∙ L) µm
Length
Internal procedure; At permanent location (S) Internal procedure IWN-L-03
6 Vernier depth gauges
Vernier calipers
Vernier height gauges
Calibration — Length
0 mm to 300 mm · CMC 0,02 mm 300 mm to 500 mm · CMC 0,03 mm 500 mm to 800 mm · CMC 0,04 mm 800 mm to 1000 mm · CMC 0,05 mm
Length
Internal procedure; At permanent location (S) Internal procedure IWN-L-02
7 Multimeters
Analogue voltmeters
Digital voltmeters
Power quality meters
Calibrators
Power supplies
Reference sources
Calibration — DC voltage
1 mV to 1 V · CMC 8 ∙ 10⁻⁶ ∙ U + 0,6 µV 1 V to 10 V · CMC 8,5 ∙ 10⁻⁶ ∙ U + 7,0 µV 10 V to 100 V · CMC 1,1 ∙ 10⁻⁵ ∙ U + 0,1 mV 100 V to 1000 V · CMC 1,2 ∙ 10⁻⁵ ∙ U + 1,3 mV
DC voltage
Internal procedure; Direct method; At permanent location (S) Internal procedures IWN-E-05 IWN-E-04 IWN-E-05 IWN-E-05 IWN-E-03 IWN-E-07
8 Multimeters
Analogue ammeters
Digital ammeters
Power quality meters
Calibrators
Power supplies
Reference sources
Calibration — DC current
0,5 µA to 10 mA · CMC 2 ∙ 10⁻⁵ ∙ I + 4 nA 10 mA to 100 mA · CMC 0,006 % 0,1 A to 1 A · CMC 0,03 % 1 A to 10 A · CMC 0,07 % 10 A to 20 A · CMC 0,09 %
DC current
Internal procedure; Direct method; At permanent location (S) Internal procedures IWN-E-05 IWN-E-04 IWN-E-05 IWN-E-05 IWN-E-03 IWN-E-07
9 Clamp meters Calibration — DC current
20 A to 1000 A · CMC 0,35 %
DC current
Internal procedure; Direct method; At permanent location (S) Internal procedure IWN-E-08
10 Multimeters
Analogue voltmeters
Digital voltmeters
Power quality meters
Calibrators
Power supplies
Reference sources
Calibration — AC voltage
40 Hz to 10 kHz — 1 mV to 1,4 V · CMC 0,031 % 40 Hz to 10 kHz — 1,4 V to 14 V · CMC 0,041 % 40 Hz to 10 kHz — 14 V to 140 V · CMC 0,053 % 40 Hz to 10 kHz — 140 V to 1000 V · CMC 0,066 %
AC voltage
Internal procedure; Direct method; At permanent location (S) Internal procedures IWN-E-05 IWN-E-04 IWN-E-05 IWN-E-05 IWN-E-03 IWN-E-07
11 Multimeters
Analogue ammeters
Digital ammeters
Calibrators
Power supplies
Reference sources
Power quality meters
Residual current device testers
Calibration — AC current
40 Hz to 1 kHz — 10 µA to 2 A · CMC 0,12 % 40 Hz to 500 Hz — 2 A to 20 A · CMC 0,15 %
AC current
Internal procedure; Direct method; At permanent location (S) Internal procedures IWN-E-05 IWN-E-04 IWN-E-05 IWN-E-07 IWN-E-03
12 Clamp meters Calibration — AC current
50 Hz — 20 A to 1000 A · CMC 0,67 %
AC current
Internal procedure; Direct method; At permanent location (S) Internal procedure IWN-E-08
13 Power quality meters
Insulation resistance meters
Earth resistance meters
Calibration — DC resistance
0,01 Ω to 10 Ω · CMC 5 ∙ 10⁻⁴ ∙ R + 1 mΩ 10 Ω to 100 Ω · CMC 5 ∙ 10⁻⁴ ∙ R + 10 mΩ 100 Ω to 1000 Ω · CMC 5 ∙ 10⁻⁴ ∙ R + 0,1 Ω 1 kΩ to 10 kΩ · CMC 5 ∙ 10⁻⁴ ∙ R + 1 Ω 0,01 MΩ to 1 GΩ · CMC 0,33 %
DC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedure IWN-E-03
14 Multimeters
Digital ohmmeters
Analogue ohmmeters
Calibration — DC resistance
0,001 Ω to 100 Ω · CMC 2 ∙ 10⁻⁵ ∙ R + 0,15 mΩ 100 Ω to 1000 Ω · CMC 1,5 ∙ 10⁻⁵ ∙ R + 1 mΩ 1 kΩ to 10 kΩ · CMC 1,7 ∙ 10⁻⁵ ∙ R + 10 mΩ 10 kΩ to 100 kΩ · CMC 1,8 ∙ 10⁻⁵ ∙ R + 1 Ω 100 kΩ to 1000 kΩ · CMC 2,3 ∙ 10⁻⁵ ∙ R + 2 Ω 1 MΩ to 100 MΩ · CMC 0,01 %
DC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedure IWN-E-05
15 Fixed resistors
Resistance standards
Calibration — DC resistance
0,001 Ω · CMC 0,012 % 0,01 Ω · CMC 0,006 % 0,1 Ω; 1 Ω; 10 Ω; 100 Ω · CMC 0,002 % 1 kΩ; 10 kΩ · CMC 0,002 % 100 kΩ; 1000 kΩ · CMC 0,003 %
DC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedure IWN-E-01
16 Variable resistors
Resistance standards
Resistance calibrators
Calibration — DC resistance
0,001 Ω to 100 Ω · CMC 0,002 ∙ 10⁻² ∙ R + 0,15 mΩ 100 Ω to 1000 Ω · CMC 0,0015 ∙ 10⁻² ∙ R + 1 mΩ 1 kΩ to 10 kΩ · CMC 0,017 ∙ R + 10 mΩ 10 kΩ to 100 kΩ · CMC 0,018 ∙ R + 1 Ω 100 kΩ to 1000 kΩ · CMC 0,023 ∙ R + 2 Ω 1 MΩ to 100 MΩ · CMC 0,01 % 100 MΩ to 1GΩ · CMC 0,1 %
DC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedures IWN-E-02 IWN-E-07
17 Power quality meters
Fault loop resistance meters
Calibration — AC resistance
50 Hz — 0,4 Ω to 1000 Ω · CMC 5,8 ∙ 10⁻³ ∙ R + 0,02 Ω
AC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedure IWN-E-03
18 Analogue single-phase active power meters
Digital single-phase active power meters
Calibration — DC power
1 V to 640 V; 0,1 A to 30 A — 0,1 W to 10 kW · CMC 0,05 %
DC power
Internal procedure; Indirect comparison method; At permanent location (S) Internal procedure IWN-E-06
19 Analogue single-phase active power meters
Digital single-phase active power meters
Analogue three-phase active power meters
Digital three-phase active power meters
Calibration — AC power
50 Hz; 0,5 V to 500 V; 0,001 A to 120 A; cos φ = 1 — 0,1 W to 10 kW (1-phase) · CMC 0,05 % 50 Hz; 0,5 V to 500 V; 0,001 A to 120 A; cos φ = 1 — 0,3 W to 30 kW (3-phase) · CMC 0,05 %
AC power
Internal procedure; Direct comparison method; At permanent location (S) Internal procedure IWN-E-06
20 pH simulators Calibration — Electrical simulation of quantities
- pH — 0 to 14 · CMC 0,0002 - DC voltage — -2000 mV to 2000 mV · CMC 2,5 ∙ 10⁻⁵ ∙ U + 0,01 mV
Electrical simulation of quantities
Internal procedure; Electrical method; At permanent location (S) Internal procedure IWN-F-02
21 Power network parameter meters Calibration — Time (time interval)
20 ms to 430 ms · CMC 1,1 ms
Time (time interval)
Internal procedure; Direct method; At permanent location (S) Internal procedure IWN-E-03
22 Electronic stopwatches Calibration — Time (time interval)
0 h to 24 h · CMC 0,02 s + 4,0 · 10⁻⁷ · τ
Time (time interval)
Internal procedure; Direct method; At permanent location (S) Internal procedure IWN-T-02
23 Electrically controlled electronic timers Calibration — Time (time interval)
0 s to 1000 s · CMC 2,4 ms
Time (time interval)
Internal procedure; Direct method; At permanent location (S) Internal procedure IWN-T-03
24 Mechanical stopwatches Calibration — Time (time interval)
0 h to 1 h · CMC 0,1 s + 2,0 · 10⁻⁵ · τ
Time (time interval)
Internal procedure; Direct method; At permanent location (S) Internal procedure IWN-T-01
25 Hygrometers
Thermohygrometers
Calibration — Relative humidity
15 °C — 38 %rh to 80 %rh · CMC 0,012 ∙ r + 0,8 %rh 20 °C — 27 %rh to 80 %rh · CMC 0,012 ∙ r + 0,8 %rh 25 °C to 50 °C — 20 %rh to 80 %rh · CMC 0,012 ∙ r + 0,8 %rh
Relative humidity
Internal procedure; At permanent location (S) Internal procedure IWN-C-02
26 Spectrophotometers Calibration — Optical density of spectral transmittance
Liquid filters; wavelength: ( 350, 313, 257, 235 ) nm; values given are nominal values — PDC Blank: 0,0366; 0,0395; 0,0439; 0,0508 · CMC 0,004 Liquid filters; wavelength: ( 350, 313, 257, 235 ) nm; values given are nominal values — PDC 20 mg/l: 0,2500; 0,1375; 0,3313; 0,2998 · CMC 0,004 Liquid filters; wavelength: ( 350, 313, 257, 235 ) nm; values given are nominal values — PDC 40 mg/l: 0,4563; 0,2303; 0,6085; 0,5378 · CMC 0,005 Liquid filters; wavelength: ( 350, 313, 257, 235 ) nm; values given are nominal values — PDC 60 mg/l: 0,6745; 0,3267; 0,9024; 0,7897 · CMC 0,006 Liquid filters; wavelength: ( 350, 313, 257, 235 ) nm; values given are nominal values — PDC 80 mg/l: 0,8874; 0,4227; 1,1926; 1,0378 · CMC 0,007 Liquid filters; wavelength: ( 350, 313, 257, 235 ) nm; values given are nominal values — PDC 100 mg/l: 1,1045; 0,5191; 1,4886; 1,2890 · CMC 0,008 spectral range 400 nm to 820 nm — 0 to 0,5 · CMC 0,004 spectral range 400 nm to 820 nm — 0,5 to 1,0 · CMC 0,005 spectral range 400 nm to 820 nm — 1,0 to 1,4 · CMC 0,006
Optical density of spectral transmittance
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure IWN-O-01
27 Spectrophotometers Calibration — Spectral transmittance
spectral range 400 nm to 820 nm — 0,05 to 0,1 · CMC 0,002 spectral range 400 nm to 820 nm — 0,1 to 0,3 · CMC 0,003 spectral range 400 nm to 820 nm — 0,3 to 0,6 · CMC 0,005 spectral range 400 nm to 820 nm — 0,6 to 1,0 · CMC 0,006
Spectral transmittance
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure IWN-O-01
28 Spectrophotometers Calibration — Spectral transmittance
- wavelength — 270 nm to 810 nm · CMC 0,2 nm
Spectral transmittance
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure IWN-O-01
29 Bourdon tube pressure gauges
Electronic pressure gauges
Calibration — Pressure
gauge pressure – negative and positive pressure (gas) — -0,1 MPa to 0,06 MPa · CMC 4 · 10⁻⁵ MPa gauge pressure – negative and positive pressure (gas) — 0,06 MPa to 0,15 MPa · CMC 0,1 % gauge pressure – negative and positive pressure (gas) — 0,15 MPa to 0,6 MPa · CMC 2 · 10⁻⁴ MPa gauge pressure – negative and positive pressure (gas) — 0,6 MPa to 7 MPa · CMC 0,035 % gauge pressure – positive pressure (liquid) — 0,02 MPa to 0,6 MPa · CMC 2,5 · 10⁻⁴ MPa gauge pressure – positive pressure (liquid) — 0,6 MPa to 5 MPa · CMC 0,1 % gauge pressure – positive pressure (liquid) — 5 MPa to 70 MPa · CMC 0,035 % gauge pressure – positive pressure (liquid) — 70 MPa to 100 MPa · CMC 0,05 %
Pressure
Internal procedure; Direct comparison method; At permanent location (S) Internal procedure IWN-P-01
30 Pressure transmitters Calibration — Pressure
gauge pressure – negative and positive pressure (gas) — -0,1 MPa to 0,06 MPa · CMC 4 · 10⁻⁵ MPa + 0,1 % fs gauge pressure – negative and positive pressure (gas) — 0,06 MPa to 0,15 MPa · CMC 0,1 % + 0,04 % fs gauge pressure – negative and positive pressure (gas) — 0,15 MPa to 0,6 MPa · CMC 2 · 10⁻⁴ MPa + 0,01 % fs gauge pressure – negative and positive pressure (gas) — 0,6 MPa to 7 MPa · CMC 0,035 % + 0,01 % fs gauge pressure – positive pressure (liquid) — 0,02 MPa to 0,6 MPa · CMC 2,5 · 10⁻⁴ MPa + 0,04 % fs gauge pressure – positive pressure (liquid) — 0,6 MPa to 5 MPa · CMC 0,1 % + 0,04 % fs gauge pressure – positive pressure (liquid) — 5 MPa to 70 MPa · CMC 0,035 % + 0,04 % fs gauge pressure – positive pressure (liquid) — 70 MPa to 100 MPa · CMC 0,05 % + 0,04 % fs
Pressure
Internal procedure; Direct comparison method; At permanent location (S) Internal procedure IWN-P-01
31 Electrical thermometers (including electronic) for air temperature measurement (calibration in a climatic chamber) Calibration — Temperature (electrical thermometry)
0 °C to 50 °C · CMC 0,25 °C
Temperature (electrical thermometry)
Internal procedure; At permanent location (S) Internal procedure IWN-C-02
32 Non-automatic electronic weighing instruments Calibration — Mass (weighing instruments)
up to 200 g · CMC 7,5 · 10⁻⁵ % 0,2 kg do 30 kg · CMC 2,4 · 10⁻⁴ %
Mass (weighing instruments)
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure IWN-M-02 based on EURAMET cg-18 v 4.0
33 Mass standards and weights of accuracy class F1 Calibration — Mass (weights and mass standards)
1 mg; 2 mg; 5 mg · CMC 0,006 mg 10 mg · CMC 0,008 mg 20 mg · CMC 0,010 mg 50 mg · CMC 0,013 mg 100 mg · CMC 0,015 mg 200 mg · CMC 0,020 mg 500 mg · CMC 0,025 mg 1g · CMC 0,03 mg 2g · CMC 0,04 mg 5g · CMC 0,05 mg 10 g · CMC 0,06 mg 20 g · CMC 0,08 mg 50 g · CMC 0,10 mg 100 g · CMC 0,15 mg 200 g · CMC 0,3 mg 500 g · CMC 0,8 mg 1 kg · CMC 1,5 mg 2 kg · CMC 3 mg 5 kg · CMC 8 mg 10 kg · CMC 15 mg
Mass (weights and mass standards)
Internal procedure; At permanent location (S) Internal procedure IWN-M-01 based on OIML R 111-1:2004 Annex C
34 Mass standards and weights of accuracy class F2 Calibration — Mass (weights and mass standards)
1 mg; 2 mg; 5 mg · CMC 0,020 mg 10 mg · CMC 0,025 mg 20 mg · CMC 0,03 mg 50 mg · CMC 0,04 mg 100 mg · CMC 0,05 mg 200 mg · CMC 0,06 mg 500 mg · CMC 0,08 mg 1g · CMC 0,10 mg 2g · CMC 0,13 mg 5g · CMC 0,15 mg 10 g · CMC 0,20 mg 20 g · CMC 0,25 mg 50 g · CMC 0,3 mg 100 g · CMC 0,5 mg 200 g · CMC 1,0 mg 500 g · CMC 2,5 mg 1 kg · CMC 5 mg 2 kg · CMC 10 mg 5 kg · CMC 25 mg 10 kg · CMC 50 mg
Mass (weights and mass standards)
Internal procedure; At permanent location (S) Internal procedure IWN-M-01 based on OIML R 111-1:2004 Annex C
35 Mass standards and weights of accuracy class M1 Calibration — Mass (weights and mass standards)
1 mg; 2 mg; 5 mg · CMC 0,06 mg 10 mg · CMC 0,08 mg 20 mg · CMC 0,10 mg 50 mg · CMC 0,13 mg 100 mg · CMC 0,15 mg 200 mg · CMC 0,20 mg 500 mg · CMC 0,25 mg 1g · CMC 0,3 mg 2g · CMC 0,4 mg 5g · CMC 0,5 mg 10 g · CMC 0,6 mg 20 g · CMC 0,8 mg 50 g · CMC 1,0 mg 100 g · CMC 1,5 mg 200 g · CMC 3 mg 500 g · CMC 8 mg 1 kg · CMC 15 mg 2 kg · CMC 30 mg 5 kg · CMC 80 mg 10 kg · CMC 150 mg
Mass (weights and mass standards)
Internal procedure; At permanent location (S) Internal procedure IWN-M-01 based on OIML R 111-1:2004 Annex C

Reference standards (23)

EURAMET cg-18 v 4.0
IWN-C-02
IWN-E-01
IWN-E-02
IWN-E-03
IWN-E-04
IWN-E-05
IWN-E-06
IWN-E-07
IWN-E-08
IWN-F-01
IWN-F-02
IWN-L-02
IWN-L-03
IWN-L-04
IWN-M-01
IWN-M-02
IWN-O-01
IWN-P-01
IWN-T-01
IWN-T-02
IWN-T-03
OIML R 111-1:2004 Załącznik C

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20089