🇵🇱 Okręgowy Urząd Miar w Bydgoszczy PL
Metrology & calibration
Okręgowy Urząd Miar w Bydgoszczy is a calibration laboratory accredited by PCA under number AP 088 (Bydgoszcz, Poland). Its accreditation scope covers 61 calibration items in the following areas: Metrology & calibration. Calibrated items include: Multimeters, Calibrators, Power quality meters, - gauge pressure (liquid). Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S), Internal procedure; At permanent location (S), Internal procedure; At permanent location (S) and outside of it (P).
At a glance
- Accreditation number: PCA AP 088
- Calibration items in scope: 61
- Types of calibrated items: 62
- Calibration principles used: 17
- City: Bydgoszcz, Poland
- Valid until: 18-01-2030
- Accreditation number
- AP 088
- Accreditation body
- PCA
- Address
- ul. Królowej Jadwigi 25, 85-231 Bydgoszcz
- City
- Bydgoszcz, Poland
- Division
- Calibration Laboratories Group
- Valid until
- 18-01-2030
What this laboratory calibrates (62)
- Multimeters — 6 calibration items
- Calibrators — 4 calibration items
- Power quality meters — 4 calibration items
- - gauge pressure (liquid) — 2 calibration items
- Analogue ammeters — 2 calibration items
- Analogue dial indicators — 2 calibration items
- Analogue voltmeters — 2 calibration items
- Bourdon tube pressure gauges — 2 calibration items
- Clamp meters — 2 calibration items
- Digital ammeters — 2 calibration items
- Digital voltmeters — 2 calibration items
- Electrical thermometers (including electronic) — 2 calibration items
- Electrical thermometers (with temperature recording) — 2 calibration items
- Electronic pressure gauges — 2 calibration items
- Gauge blocks of classes 0, 1, 2 (ceramic) — 2 calibration items
- and 47 more
Calibration principles (17)
- Internal procedure; Direct method; At permanent location (S) — 16 calibration items
- Internal procedure; At permanent location (S) — 15 calibration items
- Internal procedure; At permanent location (S) and outside of it (P) — 6 calibration items
- Internal procedure; Direct method using gauge blocks; At permanent location (S) — 6 calibration items
- Internal procedure; Comparison method using a two-probe comparator; At permanent location (S) — 2 calibration items
- Internal procedure; Direct method using angle gauge blocks; At permanent location (S) — 2 calibration items
- Internal procedure; Electrical method; At permanent location (S) — 2 calibration items
- Internal procedure; Indirect method using a goniometer; At permanent location (S) — 2 calibration items
- Internal procedure; Measurement with clamps Direct method; At permanent location (S) — 2 calibration items
- Internal procedure; Comparison method Calibration in a climatic chamber; At permanent location (S) — 1 calibration item
- Internal procedure; Comparison method Calibration in liquid baths; At permanent location (S) — 1 calibration item
- Internal procedure; Direct / indirect method; At permanent location (S) — 1 calibration item
- Internal procedure; Direct method using a micrometer head; At permanent location (S) — 1 calibration item
- Internal procedure; Direct method using roughness specimens; At permanent location (S) — 1 calibration item
- Internal procedure; Indirect method using a contact profilometer; At permanent location (S) — 1 calibration item
- and 2 more
Certificate information
- Issue date
- 19.12.2025
- Issue no.
- 23
- Certificate date
- 28.11.2024
- Accreditation cycle
- 19.12.2025 — 18.01.2030
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (61)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Analogue dial indicators | Calibration — Length 0 mm to 50 mm · CMC 2 µm Length |
Internal procedure; Direct method using a micrometer head; At permanent location (S) | IW/LW1/12 | |
| 2 | Analogue dial indicators | Calibration — Length 0 mm to 50 mm · CMC 0,002 mm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | IW/LW1/12 | |
| 3 | Digital indicators | Calibration — Length 0 mm to 50 mm · CMC 0,002 mm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | IW/LW1/12 | |
| 4 | Internal micrometers | Calibration — Length 5 mm to 30 mm · CMC 1,6 µm 30 mm to 55 mm · CMC 2,1 µm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | IW/LW1/10 | |
| 5 | External micrometers | Calibration — Length 0 mm to 25 mm · CMC 1,3 µm 25 mm to 50 mm · CMC 1,8 µm 50 mm to 75 mm · CMC 2,4 µm 75 mm to 100 mm · CMC 3,1 µm 100 mm to 125 mm · CMC 3,8 µm 125 mm to 150 mm · CMC 4,4 µm 150 mm to 175 mm · CMC 5,1 µm 175 mm to 200 mm · CMC 5,8 µm 200 mm do 225 mm · CMC 6,5 µm 225 mm do 250 mm · CMC 7,1 µm 250 mm do 275 mm · CMC 7,9 µm 275 mm do 300 mm · CMC 8,6 µm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | IW/LW1/10 | |
| 6 | Gauge blocks of classes 0, 1, 2 (steel) | Calibration — Length 0,5 mm to 100 mm · CMC Q[54; 1,23 ∙ L] nm Length |
Internal procedure; At permanent location (S) | IW/LW1/05 based on PN-EN ISO 3650:2000 | |
| 7 | Gauge blocks of classes 0, 1, 2 (ceramic) | Calibration — Length 0,5 mm to 100 mm · CMC Q[59; 1,17 ∙ L] nm Length |
Internal procedure; At permanent location (S) | IW/LW1/05 based on PN-EN ISO 3650:2000 | |
| 8 | Gauge blocks of classes 0, 1, 2 (steel) | Calibration — Length 125 mm to 500 mm · CMC Q[68; 1,25 ∙ L] nm Length |
Internal procedure; Comparison method using a two-probe comparator; At permanent location (S) | IW/LW1/05 | |
| 9 | Gauge blocks of classes 0, 1, 2 (ceramic) | Calibration — Length 125 mm to 500 mm · CMC Q[76; 2,04 ∙ L] nm Length |
Internal procedure; Comparison method using a two-probe comparator; At permanent location (S) | IW/LW1/05 | |
| 10 | Calipers | Calibration — Length 0 mm to 200 mm · CMC 0,014 mm 0 mm do 300 mm · CMC 0,015 mm 0 mm do 350 mm · CMC 0,016 mm 0 mm do 400 mm · CMC 0,017 mm 0 mm do 500 mm · CMC 0,019 mm 0 mm to 600 mm · CMC 0,021 mm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | IW/LW1/09 | |
| 11 | 90° try squares | Calibration — Angle squareness of the right angle: external — up to 400 mm · CMC 8 µm squareness of the right angle: internal — up to 400 mm · CMC 9 µm Angle |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | IW/LW1/02 | |
| 12 | Analogue universal bevel protractors | Calibration — Angle 4 × 90° · CMC 4′ Angle |
Internal procedure; Direct method using angle gauge blocks; At permanent location (S) | IW/LW1/01 | |
| 13 | Universal bevel protractors with digital readout | Calibration — Angle 0° to 360° · CMC 0,9′ Angle |
Internal procedure; Direct method using angle gauge blocks; At permanent location (S) | IW/LW1/01 | |
| 14 | Johansson angle gauge blocks | Calibration — Angle 0° to 360° · CMC 3,8″ Angle |
Internal procedure; Indirect method using a goniometer; At permanent location (S) | IW/LW1/04 | |
| 15 | Kusznikow and wringing angle gauge blocks | Calibration — Angle 0° to 360° · CMC 3,8″ Angle |
Internal procedure; Indirect method using a goniometer; At permanent location (S) | IW/LW1/04 | |
| 16 | Contact profilometers | Calibration — Length (surface geometry) Ra=0,446 µm · CMC 0,031 µm Rz=1,201 µm · CMC 0,229 µm Ra=0,621 µm · CMC 0,035 µm Rz=1,777 µm · CMC 0,190 µm Ra=2,593 µm · CMC 0,081 µm Rz=8,89 µm · CMC 0,284 µm Ra=5,91 µm · CMC 0,191 µm Rz=22,07 µm · CMC 1,647 µm Length (surface geometry) |
Internal procedure; Direct method using roughness specimens; At permanent location (S) | IW/LW1/16 | |
| 17 | Roughness specimens of types C and D | Calibration — Length (surface geometry) Rₐ — 0,05 µm to 30 µm · CMC Q[0,054; 0,039 · Rₐ] Rₚ, Rᵥ, R_z, Rₜ — 0,05 µm to 30 µm · CMC Q[0,09; 0,055 · R] Length (surface geometry) |
Internal procedure; Indirect method using a contact profilometer; At permanent location (S) | IW/LW1/14 | |
| 18 | Hygrometers Thermohygrometers |
Calibration — Relative humidity 10 °C; 50 %rh to 85 %rh — 50 %rh · CMC 0,8 %rh 10 °C; 50 %rh to 85 %rh — 85 %rh · CMC 1,5 %rh 20 °C to 23 °C; 20 %rh to 85 %rh — 20 %rh · CMC 0,5 %rh 20 °C to 23 °C; 20 %rh to 85 %rh — 85 %rh · CMC 1,4 %rh 40 °C; 20 %rh to 60 %rh — 20 %rh · CMC 0,7 %rh 40 °C; 20 %rh to 60 %rh — 60 %rh · CMC 1,3 %rh Relative humidity |
Internal procedure; Indirect method; At permanent location (S) | IW/LW1/15 | |
| 19 | Piston gauges - gauge pressure (liquid) |
Calibration — Pressure 0,02 MPa to 60 MPa · CMC 2,5 · 10⁻⁴ · p Pressure |
Internal procedure; At permanent location (S) | IW/LW1/11 | |
| 20 | Bourdon tube pressure gauges Electronic pressure gauges - gauge pressure (gas) |
Calibration — Pressure -0,05 MPa to -0,001 MPa · CMC 1 · 10⁻⁵ MPa -0,1 MPa to -0,05 MPa · CMC 1 · 10⁻⁵ MPa 0,001 MPa to 0,14 MPa · CMC 1 · 10⁻⁵ MPa 0,15 MPa to 0,2 MPa · CMC 2 · 10⁻⁵ MPa 0,2 MPa to 1 MPa · CMC 1 · 10⁻⁴ MPa Pressure |
Internal procedure; At permanent location (S) | IW/LW1/08 | |
| 21 | Bourdon tube pressure gauges Electronic pressure gauges - gauge pressure (liquid) |
Calibration — Pressure 0,02 MPa to 0,4 MPa · CMC 1 · 10⁻⁴ MPa 0,4 MPa to 1 MPa · CMC 4 · 10⁻⁴ MPa 1 MPa to 3 MPa · CMC 1 · 10⁻³ MPa 3 MPa to 4 MPa · CMC 2 · 10⁻³ MPa 4 MPa to 6 MPa · CMC 4 · 10⁻³ MPa 6 MPa to 10 MPa · CMC 5 · 10⁻³ MPa 10 MPa to 27 MPa · CMC 1 · 10⁻² MPa 28 MPa to 60 MPa · CMC 2 · 10⁻² MPa 60 MPa to 100 MPa · CMC 6 · 10⁻² MPa 100 MPa to 200 MPa · CMC 1 · 10⁻¹ MPa 210 MPa to 250 MPa · CMC 3 · 10⁻¹ MPa Pressure |
Internal procedure; At permanent location (S) | IW/LW1/08 | |
| 22 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) |
Calibration — Temperature (electrical thermometry) -80 °C to -26 °C · CMC 0,030 °C -25 °C to -11 °C · CMC 0,060 °C -10 °C to 99 °C · CMC 0,050 °C 100 °C to 199 °C · CMC 0,060 °C 200 °C to 250 °C · CMC 0,080 °C 0 °C · CMC 0,020 °C Temperature (electrical thermometry) |
Internal procedure; Comparison method Calibration in liquid baths; At permanent location (S) | IW/LW1/07 | |
| 23 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) |
Calibration — Temperature (electrical thermometry) -30 °C to 0 °C · CMC 0,5 °C 1 °C to 40 °C · CMC 0,2 °C 41 °C to 80 °C · CMC 0,3 °C Temperature (electrical thermometry) |
Internal procedure; Comparison method Calibration in a climatic chamber; At permanent location (S) | IW/LW1/15 | |
| 24 | Liquid-in-glass thermometers | Calibration — Temperature (non-electrical thermometry) -50 °C to -26 °C · CMC 0,03 °C -25 °C to -11 °C · CMC 0,05 °C -10 °C to 100 °C · CMC 0,04 °C 101 °C to 199 °C · CMC 0,06 °C 200 °C to 250 °C · CMC 0,08 °C 0 °C · CMC 0,02 °C Temperature (non-electrical thermometry) |
Internal procedure; At permanent location (S) | IW/LW1/06 based on OIML R 133:2002 | |
| 25 | Radiation pyrometers | Calibration — Temperature (radiation thermometry) -15 °C to -1 °C · CMC 1,6 °C 0 °C to 50 °C · CMC 1,1 °C 51 °C to 100 °C · CMC 1,4 °C 101 °C to 163 °C · CMC 2,3 °C 164 °C to 300 °C · CMC 2,4 °C 301 °C to 500 °C · CMC 3,0 °C Temperature (radiation thermometry) |
Internal procedure; At permanent location (S) | IW/LW1/13 | |
| 26 | Non-automatic electronic weighing instruments | Calibration — Mass (weighing instruments) do 1 kg · CMC 5 · 10⁻⁵ % 1 kg to 10 kg · CMC 1,7 · 10⁻⁴ % 10 kg do 50 kg · CMC 8 · 10⁻⁴ % 50 kg do 500 kg · CMC 1,3 · 10⁻³ % Mass (weighing instruments) |
Internal procedure; At permanent location (S) and outside of it (P) | IW/LW2/01 based on EURAMET cg-18 v. 4.0 | |
| 27 | Load weights | Calibration — Mass (weights and mass standards) 1 g to 5 g · CMC 0,04 mg 10 g to 100 g · CMC 0,12 mg 200 g · CMC 0,45 mg 500 g · CMC 1,00 mg 1 kg · CMC 1,73 mg 2 kg · CMC 3,29 mg 5 kg · CMC 8,40 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | IW/LW2/02 based on OIML R 111-1:2004 Annex C | |
| 28 | Mass standards and weights of accuracy class E2 | Calibration — Mass (weights and mass standards) 1 mg · CMC 0,0020 mg 2 mg · CMC 0,0020 mg 5 mg · CMC 0,0020 mg 10 mg · CMC 0,0026 mg 20 mg · CMC 0,003 mg 50 mg · CMC 0,004 mg 100 mg · CMC 0,005 mg 200 mg · CMC 0,006 mg 500 mg · CMC 0,008 mg 1g · CMC 0,010 mg 2g · CMC 0,012 mg 5g · CMC 0,015 mg 10 g · CMC 0,020 mg 20 g · CMC 0,025 mg 50 g · CMC 0,03 mg 100 g · CMC 0,05 mg 200 g · CMC 0,10 mg 500 g · CMC 0,25 mg 1 kg · CMC 0,50 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | IW/LW2/02 based on OIML R 111-1:2004 Annex C | |
| 29 | Mass standards and weights of accuracy class F1 | Calibration — Mass (weights and mass standards) 1 mg, 2 mg, 5 mg · CMC 0,006 mg 10 mg · CMC 0,008 mg 20 mg · CMC 0,010 mg 50 mg · CMC 0,013 mg 100 mg · CMC 0,015 mg 200 mg · CMC 0,020 mg 500 mg · CMC 0,025 mg 1g · CMC 0,03 mg 2g · CMC 0,04 mg 5g · CMC 0,05 mg 10 g · CMC 0,06 mg 20 g · CMC 0,08 mg 50 g · CMC 0,10 mg 100 g · CMC 0,15 mg 200 g · CMC 0,3 mg 500 g · CMC 0,8 mg 1 kg · CMC 1,5 mg 2 kg · CMC 3,0 mg 5 kg · CMC 8 mg 10 kg · CMC 15 mg 20 kg · CMC 30 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | IW/LW2/02 based on OIML R 111-1:2004 Annex C | |
| 30 | Mass standards and weights of accuracy class F2 | Calibration — Mass (weights and mass standards) 1 mg, 2 mg, 5 mg · CMC 0,020 mg 10 mg · CMC 0,025 mg 20 mg · CMC 0,03 mg 50 mg · CMC 0,04 mg 100 mg · CMC 0,05 mg 200 mg · CMC 0,06 mg 500 mg · CMC 0,08 mg 1g · CMC 0,10 mg 2g · CMC 0,13 mg 5g · CMC 0,15 mg 10 g · CMC 0,2 mg 20 g · CMC 0,25 mg 50 g · CMC 0,3 mg 100 g · CMC 0,5 mg 200 g · CMC 1,0 mg 500 g · CMC 2,5 mg 1 kg · CMC 5 mg 2 kg · CMC 10 mg 5 kg · CMC 25 mg 10 kg · CMC 50 mg 20 kg · CMC 100 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | IW/LW2/02 based on OIML R 111-1:2004 Annex C | |
| 31 | Mass standards and weights of accuracy class M1 | Calibration — Mass (weights and mass standards) 1 mg, 2 mg, 5 mg · CMC 0,06 mg 10 mg · CMC 0,08 mg 20 mg · CMC 0,10 mg 50 mg · CMC 0,13 mg 100 mg · CMC 0,15 mg 200 mg · CMC 0,20 mg 500 mg · CMC 0,25 mg 1g · CMC 0,3 mg 2g · CMC 0,4 mg 5g · CMC 0,5 mg 10 g · CMC 0,6 mg 20 g · CMC 0,8 mg 50 g · CMC 1,0 mg 100 g · CMC 1,5 mg 200 g · CMC 3 mg 500 g · CMC 8 mg 1 kg · CMC 15 mg 2 kg · CMC 30 mg 5 kg · CMC 80 mg 10 kg · CMC 150 mg 20 kg · CMC 300 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | IW/LW2/02 based on OIML R 111-1:2004 Annex C | |
| 32 | 25 kg mass standards | Calibration — Mass (weights and mass standards) 25 kg · CMC 380 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | IW/LW2/02 based on OIML R 111-1:2004 Annex C | |
| 33 | Torque wrenches Torque screwdrivers |
Calibration — Torque 0,04 Nm to 1500 Nm · CMC 0,5 % Torque |
Internal procedure; At permanent location (S) | IW/LW2/04 based on PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017 | |
| 34 | pH meters | Calibration — pH pH — 0 to 14 · CMC 0,003 DC voltage — -1400 mV to 1400 mV · CMC 0,2 mV pH |
Internal procedure; Electrical method; At permanent location (S) | IW/LW3/11 | |
| 35 | pH meters pH electrodes |
Calibration — pH pH — 1,00 to 11,00 · CMC 0,04 pH — 11,01 to 13,00 · CMC 0,3 slope of the characteristic — 40,0 mV to 80,0 mV · CMC 0,4 mV electrode efficiency β — 75,0 % to 102,0 % · CMC 0,8 % zero point (pH for E=0 mV) — 2,00 to 10,00 · CMC 0,03 pH |
Internal procedure; Method using reference materials; At permanent location (S) | IW/LW3/19 | |
| 36 | Conductivity meters | Calibration — Specific electrical conductivity (conductometry) 0,1 µS∙cm⁻¹ to 2 µS∙cm⁻¹ · CMC 0,002 µS∙cm⁻¹ 0,002 mS∙cm⁻¹ to 100 mS∙cm⁻¹ · CMC 0,09 % 100 mS∙cm⁻¹ to 200 mS∙cm⁻¹ · CMC 0,13 % Specific electrical conductivity (conductometry) |
Internal procedure; Electrical method; At permanent location (S) | IW/LW3/12 | |
| 37 | Multimeters Digital voltmeters Analogue voltmeters Power quality meters |
Calibration — DC voltage 100 µV to 1 mV · CMC 0,064 % 1 mV to 100 mV · CMC 0,0015 % 100 mV to 1 V · CMC 0,00076 % 1 V to 10 V · CMC 0,00044 % 10 V to 100 V · CMC 0,00077 % 100 V to 1000 V · CMC 0,00088 % DC voltage |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/02 IW/LW3/09 IW/LW3/18 | |
| 38 | Calibrators Power supplies |
Calibration — DC voltage 100 µV to 100 mV · CMC 0,0012 % 100 mV to 1 V · CMC 0,00073 % 1 V to 10 V · CMC 0,00078 % 10 V to 1000 V · CMC 0,0013 % DC voltage |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/01 IW/LW3/16 | |
| 39 | Multimeters Digital ammeters Analogue ammeters Power quality meters |
Calibration — DC current 10 µA to 100 µA · CMC 0,014 % 100 µA to 100 mA · CMC 0,0049 % 100 mA to 1 A · CMC 0,014 % 1 A to 10 A · CMC 0,033 % 10 A to 20 A · CMC 0,1% DC current |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/02 IW/LW3/09 IW/LW3/18 | |
| 40 | Clamp meters | Calibration — DC current 0,2 A to 20 A · CMC 0,12 % 20 A to 525 A · CMC 0,35 % 525 A to 1000 A · CMC 0,44 % DC current |
Internal procedure; Measurement with clamps Direct method; At permanent location (S) | IW/LW3/02 | |
| 41 | Calibrators Power supplies |
Calibration — DC current 10 µA to 10 mA · CMC 0,012 % 10 mA to 100 mA · CMC 0,013 % 100 mA to 1 A · CMC 0,027 % 1 A to 2 A · CMC 0,021 % 2 A to 20 A · CMC 0,046 % DC current |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/01 IW/LW3/16 | |
| 42 | Multimeters Digital voltmeters Analogue voltmeters Power quality meters |
Calibration — AC voltage 10 Hz to 33 kHz — 1 mV to 100 mV · CMC 0,021 % 10 Hz to 33 kHz — 100 mV to 100 V · CMC 0,0064 % 10 Hz to 33 kHz — 100 V to 1000 V · CMC 0,016 % 30 kHz to 100 kHz — 1 mV to 100 mV · CMC 0,06 % 30 kHz to 100 kHz — 100 mV to 10 V · CMC 0,012 % 30 kHz to 100 kHz — 10 to 100 V · CMC 0,019 % 30 kHz to 100 kHz — 100 to 750 V · CMC 0,13 % 100 kHz to 330 kHz — 1 mV to 100 mV · CMC 0,26 % 100 kHz to 330 kHz — 100 mV to 10 V · CMC 0,043 % 100 kHz to 330 kHz — 10 V to 100 V · CMC 0,15 % 300 kHz to 1 MHz — 1 V to 10 V · CMC 0,041 % AC voltage |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/02 IW/LW3/09 IW/LW3/18 | |
| 43 | Calibrators | Calibration — AC voltage 10 Hz to 50 Hz — 10 mV to 100 mV · CMC 0,077 % 10 Hz to 50 Hz — 100 mV to 100 V · CMC 0,021 % 10 Hz to 50 Hz — 100 V to 1000 V · CMC 0,021 % 50 Hz to 10 kHz — 10 mV to 100 mV · CMC 0,032 % 50 Hz to 10 kHz — 100 mV to 100 V · CMC 0,018 % 50 Hz to 10 kHz — 100 V to 1000 V · CMC 0,02 % 10 kHz to 30 kHz — 100 mV to 100 V · CMC 0,034 % 10 kHz to 30 kHz — 100 V to 1000 V · CMC 0,081 % 30 kHz to 100 kHz — 10 mV to 100 V · CMC 0,081 % 100 kHz to 300 kHz — 100 mV to 100 V · CMC 2,65 % AC voltage |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/01 | |
| 44 | Multimeters Digital ammeters Analogue ammeters Power quality meters |
Calibration — AC current 10 Hz to 1 kHz — 10 µA to 100 µA · CMC 0,038 % 10 Hz to 1 kHz — 100 µA to 100 mA · CMC 0,022 % 10 Hz to 1 kHz — 100 mA to 1 A · CMC 0,047 % 10 Hz to 1 kHz — 1 A to 10 A · CMC 0,068 % 10 Hz to 1 kHz — 10 A to 20 A · CMC 0,30 % 1 kHz to 5 kHz — 10 µA to 100 mA · CMC 0,026 % 1 kHz to 5 kHz — 100 mA to 1 A · CMC 0,072 % 1 kHz to 5 kHz — 1 A to 10 A · CMC 0,17 % 1 kHz to 5 kHz — 10 A to 20 A · CMC 0,90 % AC current |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/02 IW/LW3/09 IW/LW3/18 | |
| 45 | Clamp meters | Calibration — AC current 50 Hz — 0,02 A to 20 A · CMC 0,35 % 50 Hz — 20 A to 1000 A · CMC 0,57 % AC current |
Internal procedure; Measurement with clamps Direct method; At permanent location (S) | IW/LW3/02 | |
| 46 | Residual current device testers | Calibration — AC current 50 Hz — 10 mA to 1000 mA · CMC 1,3 % AC current |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/08 | |
| 47 | Calibrators | Calibration — AC current 10 Hz to 5 kHz — 10 µA to 100 mA · CMC 0,062 % 10 Hz to 5 kHz — 100 mA to 1 A · CMC 0,047 % 10 Hz to 5 kHz — 1 A to 2 A · CMC 0,084 % 10 Hz to 2 kHz — 2 A to 20 A · CMC 0,12 % 2 kHz to 5 kHz — 2 A to 20 A · CMC 0,32 % AC current |
Internal procedure; Direct / indirect method; At permanent location (S) | IW/LW3/01 | |
| 48 | Multimeters Digital ohmmeters |
Calibration — DC resistance 0Ω · CMC 23 µΩ 30 µΩ · CMC 2,5 % 0,0001 Ω to 0,01 Ω · CMC 1% 0,01 Ω to 1 Ω · CMC 0,12 ∙ 10⁻³ ∙ R + 0,023 mΩ 1 Ω to 10 Ω · CMC 0,0029 % 10 Ω to 100 Ω · CMC 0,0013 % 100 Ω to 10 kΩ · CMC 0,0011 % 10 kΩ to 100 kΩ · CMC 0,0014 % 100 kΩ to 1 MΩ · CMC 0,0032 % 1 MΩ to 10 MΩ · CMC 0,006 % 10 MΩ to 100 MΩ · CMC 0,021 % DC resistance |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/02 | |
| 49 | Power network parameter meters: Insulation resistance meters Continuity testers |
Calibration — DC resistance 10 kΩ to 10 GΩ · CMC 0,13 % 10 GΩ to 100 GΩ · CMC 1,2 % 0,05 Ω to 10 Ω · CMC 0,9 ∙ 10⁻³ ∙ R + 0,001 Ω 10 Ω to 1 kΩ · CMC 0,9 ∙ 10⁻³ ∙ R + 0,01 Ω DC resistance |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/05 IW/LW3/06 IW/LW3/09 | |
| 50 | Resistance calibrators Variable resistors |
Calibration — DC resistance 0,01 Ω to 0,1 Ω · CMC 1,4 ∙ 10⁻³ ∙ R + 0,014 Ω 0,1 Ω to 1 Ω · CMC 0,015 % 1 Ω to 10 Ω · CMC 0,0020 % 10 Ω to 100 Ω · CMC 0,0014 % 100 Ω to 100 kΩ · CMC 0,0011 % 100 kΩ to 1 MΩ · CMC 0,0017 % 1 MΩ to 10 MΩ · CMC 0,0045 % 10 MΩ to 1 GΩ · CMC 0,045 % DC resistance |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/01 IW/LW3/15 | |
| 51 | Power network parameter meters: Loop impedance meters Earth resistance meters |
Calibration — AC resistance 0,30 Ω to 1000 Ω · CMC 5,8 ∙ 10⁻³ ∙ R + 0,01 Ω 0,3 Ω to 20 kΩ · CMC 1,0 ∙ 10⁻³ ∙ R + 0,01 Ω AC resistance |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/06 IW/LW3/07 | |
| 52 | Residual current device testers | Calibration — Time (time interval) 20 ms to 200 ms · CMC 1,1 ms 210 ms to 400 ms · CMC 1,2 ms 410 ms to 1 s · CMC 8,2 ms Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/08 | |
| 53 | Electronic stopwatches Electronic timers (time dispensers) |
Calibration — Time (time interval) 0 h to 24 h · CMC 0,02 s + 2,8 · 10⁻⁷ · τ Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/13 | |
| 54 | Mechanical stopwatches | Calibration — Time (time interval) 0 h to 1 h · CMC 0,07 s + 1,2 · 10⁻⁵ · τ Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/17 | |
| 55 | Multimeters | Calibration — Frequency 1 Hz to 25 MHz · CMC 3 · 10⁻⁶ · f Frequency |
Internal procedure; Direct method; At permanent location (S) | IW/LW3/02 | |
| 56 | Spectrophotometers (UV) | Calibration — Optical density of spectral transmittance Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 1,0836 · CMC 0,012 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 1,0762 · CMC 0,012 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 1,0672 · CMC 0,012 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,9864 · CMC 0,012 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,9464 · CMC 0,012 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,9500 · CMC 0,012 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,6129 · CMC 0,0097 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,6040 · CMC 0,0097 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,5945 · CMC 0,0096 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,5226 · CMC 0,0096 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,4929 · CMC 0,0096 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,4943 · CMC 0,0096 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,3022 · CMC 0,0081 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,2995 · CMC 0,0081 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,2971 · CMC 0,0081 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,2869 · CMC 0,0081 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,2887 · CMC 0,0081 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,2924 · CMC 0,0081 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,0335 · CMC 0,0069 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,0339 · CMC 0,0069 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,0341 · CMC 0,0069 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,0369 · CMC 0,0070 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,0394 · CMC 0,0070 Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,0416 · CMC 0,0070 Optical density of spectral transmittance |
Internal procedure; At permanent location (S) and outside of it (P) | IW/LW3/10 | |
| 57 | Spectrophotometers (VIS) | Calibration — Optical density of spectral transmittance Zakres widmowy 400 nm to 890 nm — 0 to 0,3 · CMC 0,0036 Zakres widmowy 400 nm to 890 nm — 0,3 to 0,5 · CMC 0,0042 Zakres widmowy 400 nm to 890 nm — 0,5 to 1,0 · CMC 0,0050 Zakres widmowy 400 nm to 890 nm — 1,0 to 1,4 · CMC 0,0077 Optical density of spectral transmittance |
Internal procedure; At permanent location (S) and outside of it (P) | IW/LW3/10 | |
| 58 | Spectrophotometers (UV) | Calibration — Spectral transmittance Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,0825 · CMC 0,0037 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,0839 · CMC 0,0037 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,0857 · CMC 0,0037 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,1032 · CMC 0,0037 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,1131 · CMC 0,0037 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,1122 · CMC 0,0037 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,2438 · CMC 0,0068 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,2489 · CMC 0,0068 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,2544 · CMC 0,0068 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,3002 · CMC 0,0069 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,3214 · CMC 0,0069 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,3204 · CMC 0,0069 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,4986 · CMC 0,0095 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,5018 · CMC 0,0096 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,5046 · CMC 0,0096 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,5165 · CMC 0,0096 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,5144 · CMC 0,0096 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,5100 · CMC 0,0096 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,9258 · CMC 0,014 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,9249 · CMC 0,014 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,9245 · CMC 0,014 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,9185 · CMC 0,014 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,9132 · CMC 0,014 Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values — 0,9086 · CMC 0,014 Spectral transmittance |
Internal procedure; At permanent location (S) and outside of it (P) | IW/LW3/10 | |
| 59 | Spectrophotometers (VIS) | Calibration — Spectral transmittance Zakres widmowy 400 nm to 890 nm — 0,04 to 0,10 · CMC 0,0027 Zakres widmowy 400 nm to 890 nm — 0,1 to 0,3 · CMC 0,0028 Zakres widmowy 400 nm to 890 nm — 0,3 to 0,5 · CMC 0,0038 Zakres widmowy 400 nm to 890 nm — 0,5 to 1,0 · CMC 0,0052 Spectral transmittance |
Internal procedure; At permanent location (S) and outside of it (P) | IW/LW3/10 | |
| 60 | Spectrophotometers | Calibration — Spectral transmittance wavelength — 275 nm to 890 nm · CMC 0,20 nm (achieved for a spectral half-width of the exit slit of 1 nm) Spectral transmittance |
Internal procedure; At permanent location (S) and outside of it (P) | IW/LW3/10 | |
| 61 | Liquid-in-glass thermometers | Calibration — Temperature (non-electrical thermometry) -40 °C to -1 °C · CMC 0,07 °C 1 °C to 100 °C · CMC 0,06 °C 101 °C to 250 °C · CMC 0,13 °C 251 °C to 360 °C · CMC 0,36 °C 0 °C · CMC 0,02 °C Temperature (non-electrical thermometry) |
Internal procedure; At permanent location (S) | IW/LW1/06 based on OIML R 133:2002 | |
Reference standards (40)
EURAMET cg-18 v. 4.0
IW/LW1/01
IW/LW1/02
IW/LW1/04
IW/LW1/05
IW/LW1/06
IW/LW1/07
IW/LW1/08
IW/LW1/09
IW/LW1/10
IW/LW1/11
IW/LW1/12
IW/LW1/13
IW/LW1/14
IW/LW1/15
IW/LW1/16
IW/LW2/01
IW/LW2/02
IW/LW2/04
IW/LW3/01
IW/LW3/02
IW/LW3/05
IW/LW3/06
IW/LW3/07
IW/LW3/08
IW/LW3/09
IW/LW3/10
IW/LW3/11
IW/LW3/12
IW/LW3/13
IW/LW3/15
IW/LW3/16
IW/LW3/17
IW/LW3/18
IW/LW3/19
OIML R 111-1:2004 Załącznik C
OIML R 133:2002
PN-EN ISO 3650:2000
PN-EN ISO 6789-1:2017
PN-EN ISO 6789-2:2017