{"lab":{"_id":"6afad8088989a133b76447c2","accr_number":"AP 088","country":"PL","imported_at":"2026-11-16T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"28.11.2024","city":"Bydgoszcz","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. The value of the uncertainty covered by the CMC expressed as a percentage is the relative measurement uncertainty and refers to the percentage share of the value of the measurand.","cycle_from":"19.12.2025","cycle_to":"18.01.2030","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"3.01","pl":"pH","en":"pH","de":"pH","zh":"pH 值","cs":"pH"},{"codes":"3.02","pl":"przewodność elektryczna właściwa (konduktometria)","en":"specific electrical conductivity (conductometry)","de":"spezifische elektrische Leitfähigkeit (Konduktometrie)","zh":"电导率（电导测量）","cs":"měrná elektrická vodivost (konduktometrie)"},{"codes":"6.01","pl":"długość","en":"length","de":"Länge","zh":"长度","cs":"délka"},{"codes":"6.02","pl":"kąt","en":"angle","de":"Winkel","zh":"角度","cs":"úhel"},{"codes":"6.03","pl":"długość (geometria powierzchni)","en":"length (surface geometry)","de":"Länge (Oberflächengeometrie)","zh":"长度（表面几何）","cs":"délka (geometrie povrchu)"},{"codes":"7.01","pl":"napięcie DC","en":"DC voltage","de":"Gleichspannung","zh":"直流电压","cs":"stejnosměrné napětí (DC)"},{"codes":"7.02","pl":"prąd DC","en":"DC current","de":"DC-Strom","zh":"直流电流","cs":"proud DC"},{"codes":"7.03","pl":"napięcie AC","en":"AC voltage","de":"AC-Spannung","zh":"交流电压","cs":"napětí AC"},{"codes":"7.04","pl":"prąd AC","en":"AC current","de":"AC-Strom","zh":"交流电流","cs":"proud AC"},{"codes":"7.05","pl":"rezystancja DC","en":"DC resistance","de":"DC-Widerstand","zh":"直流电阻","cs":"odpor DC"},{"codes":"7.06","pl":"rezystancja AC","en":"AC resistance","de":"Wechselstromwiderstand","zh":"交流电阻","cs":"střídavý odpor"},{"codes":"10.01","pl":"czas (przedział czasu)","en":"time (time interval)","de":"Zeit (Zeitintervall)","zh":"时间（时间间隔）","cs":"čas (časový interval)"},{"codes":"10.02","pl":"częstotliwość","en":"frequency","de":"Frequenz","zh":"频率","cs":"frekvence"},{"codes":"12.02","pl":"moment siły","en":"torque","de":"Drehmoment","zh":"力矩","cs":"moment síly"},{"codes":"14.02","pl":"wilgotność względna","en":"relative humidity","de":"relative Feuchte","zh":"相对湿度","cs":"relativní vlhkost"},{"codes":"15.01","pl":"masa (wagi)","en":"mass (weighing instruments)","de":"Masse (Waagen)","zh":"质量（衡器）","cs":"hmotnost (váhy)"},{"codes":"15.02","pl":"masa (odważniki i wzorce masy)","en":"mass (weights and mass standards)","de":"Masse (Gewichtstücke und Massenormale)","zh":"质量（砝码和质量标准器）","cs":"hmotnost (závaží a etalony hmotnosti)"},{"codes":"16.03","pl":"gęstość optyczna widmowego współczynnika przepuszczania","en":"optical density of spectral transmittance","de":"optische Dichte des spektralen Transmissionsgrads","zh":"光谱透射比的光密度","cs":"optická hustota spektrální propustnosti"},{"codes":"16.04","pl":"widmowy współczynnik przepuszczania","en":"spectral transmittance","de":"spektraler Transmissionsgrad","zh":"光谱透射比","cs":"spektrální propustnost"},{"codes":"17.01","pl":"ciśnienie","en":"pressure","de":"Druck","zh":"压力","cs":"tlak"},{"codes":"19.01","pl":"temperatura (termometria elektryczna)","en":"temperature (electrical thermometry)","de":"Temperatur (elektrische Thermometrie)","zh":"温度（电测温）","cs":"teplota (elektrická termometrie)"},{"codes":"19.02","pl":"temperatura (termometria nieelektryczne)","en":"temperature (non-electrical thermometry)","de":"Temperatur (nichtelektrische Thermometrie)","zh":"温度（非电测温）","cs":"teplota (neelektrická termometrie)"},{"codes":"19.03","pl":"temperatura (termometria radiacyjna)","en":"temperature (radiation thermometry)","de":"Temperatur (Strahlungsthermometrie)","zh":"温度（辐射测温）","cs":"teplota (radiační termometrie)"}],"has_en":true,"has_zh":true,"issue":{"no":"23","date":"19.12.2025"},"issue_date":"19.12.2025","issue_number":"23","lab_division":"Zespół Laboratoriów Wzorcujących","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[17.9938988,53.1313081]},"map_coord":[53.1313081,17.9938988],"map_geo":"nominatim-street","methods_count":61,"name":"Okręgowy Urząd Miar w Bydgoszczy","parse_date":"2026-11-16T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-16T12:00:00.000Z","pdf_files":["AP_088.pdf"],"scope_notes":[{"pl":"Wartość niepewności pomiaru dla CMC wyrażona w postaci równania Q[a; b] oznacza pierwiastek sumy kwadratów wyrazów w nawiasach: Q[a; b] = (a² + b²)^1/2.","en":"A CMC uncertainty value expressed as Q[a; b] means the root sum of squares of the terms in brackets: Q[a; b] = (a² + b²)^1/2."}],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: pH, przewodność elektryczna właściwa (konduktometria), długość, kąt, długość (geometria powierzchni), napięcie DC, prąd DC, napięcie AC, prąd AC, rezystancja DC, rezystancja AC, czas (przedział czasu), częstotliwość, moment siły, wilgotność względna, masa (wagi), masa (odważniki i wzorce masy), gęstość optyczna widmowego współczynnika przepuszczania, widmowy współczynnik przepuszczania, ciśnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczne), temperatura (termometria radiacyjna). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"okręgowy urząd miar w bydgoszczy zespół laboratoriów wzorcujących ul. królowej jadwigi 25, 85-231 bydgoszcz laboratorium wzorcujące. wielkości mierzone: ph, przewodność elektryczna właściwa (konduktometria), długość, kąt, długość (geometria powierzchni), napięcie dc, prąd dc, napięcie ac, prąd ac, rezystancja dc, rezystancja ac, czas (przedział czasu), częstotliwość, moment siły, wilgotność względna, masa (wagi), masa (odważniki i wzorce masy), gęstość optyczna widmowego współczynnika przepuszczania, widmowy współczynnik przepuszczania, ciśnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczne), temperatura (termometria radiacyjna). w stałej lokalizacji (s) i/lub poza nią (p). ap 088 ap088 laboratorium wzorcujące wzorcowanie kalibracja ph specific electrical conductivity (conductometry) length angle length (surface geometry) dc voltage dc current ac voltage ac current dc resistance ac resistance time (time interval) frequency torque relative humidity mass (weighing instruments) mass (weights and mass standards) optical density of spectral transmittance spectral transmittance pressure temperature (electrical thermometry) temperature (non-electrical thermometry) temperature (radiation thermometry) okregowy urzad miar w bydgoszczy zespol laboratoriow wzorcujacych ul. krolowej jadwigi 25, 85-231 bydgoszcz laboratorium wzorcujace. wielkosci mierzone: ph, przewodnosc elektryczna wlasciwa (konduktometria), dlugosc, kat, dlugosc (geometria powierzchni), napiecie dc, prad dc, napiecie ac, prad ac, rezystancja dc, rezystancja ac, czas (przedzial czasu), czestotliwosc, moment sily, wilgotnosc wzgledna, masa (wagi), masa (odwazniki i wzorce masy), gestosc optyczna widmowego wspolczynnika przepuszczania, widmowy wspolczynnik przepuszczania, cisnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczne), temperatura (termometria radiacyjna). w stalej lokalizacji (s) i/lub poza nia (p). ap 088 ap088 laboratorium wzorcujace wzorcowanie kalibracja ph specific electrical conductivity (conductometry) length angle length (surface geometry) dc voltage dc current ac voltage ac current dc resistance ac resistance time (time interval) frequency torque relative humidity mass (weighing instruments) mass (weights and mass standards) optical density of spectral transmittance spectral transmittance pressure temperature (electrical thermometry) temperature (non-electrical thermometry) temperature (radiation thermometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20088,podmiot.html","source_pdf_sha256":"e8685139f86548334f8ea773646d4ea52b86dec719044ad138fd5b733de64eb4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/16/f45a117cab885427d04d6c2dd7dec110/AP%20088.pdf","status":"active","updated_at":"2026-11-16T12:00:00.000Z","valid_from":"19-01-2006","valid_until":"18-01-2030","website":"bydgoszcz.gum.gov.pl","lab_division_en":"Calibration Laboratories Group","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"lab_division_de":"Kalibrierlaborverbund","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","lab_division_zh":"校准实验室组","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"lab_division_cs":"Soubor kalibračních laboratoří","pelny_cs":true},"methods":[{"_id":"095aec5e16f0ad0805efc511","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Czujniki analogowe","test_object_en":"Analogue dial indicators","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"2 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"2 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a micrometer head; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a micrometer head","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 50 mm CMC 2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej; W stałej lokalizacji (S)","reference":"IW/LW1/12","norm_bases":["IW/LW1/12"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Czujniki analogowe Wzorcowanie — Długość\n0 mm do 50 mm CMC 2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej; W stałej lokalizacji (S) IW/LW1/12 Czujniki analogowe Wzorcowanie — Dlugosc\n0 mm do 50 mm CMC 2 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem glowicy mikrometrycznej; W stalej lokalizacji (S) IW/LW1/12","search_en":"Analogue dial indicators Calibration — Length Internal procedure; Direct method using a micrometer head; At permanent location (S) Length Internal procedure Direct method using a micrometer head At permanent location (S) IW/LW1/12","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"2 µm"}],"regulatory_area_de":"Länge","search_de":"Analoge Messuhren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Messschraubenkopf; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Messschraubenkopf Am festen Standort (S) IW/LW1/12","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Messschraubenkopf; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Messschraubenkopf","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"2 µm"}],"regulatory_area_zh":"长度","search_zh":"模拟指示表 校准 — 长度 内部程序；使用测微头的直接法；在固定地点 (S) 长度 内部程序 使用测微头的直接法 在固定地点 (S) IW/LW1/12","technique_zh":"内部程序；使用测微头的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用测微头的直接法","在固定地点 (S)"],"test_object_zh":"模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"2 µm"}],"regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím mikrometrické hlavice Ve stálé lokalitě (S) IW/LW1/12","technique_cs":"Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím mikrometrické hlavice","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry"},{"_id":"9a4cf057dd48fe17e47ee93c","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Czujniki analogowe","test_object_en":"Analogue dial indicators","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"0,002 mm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"0,002 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 50 mm CMC 0,002 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"IW/LW1/12","norm_bases":["IW/LW1/12"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Czujniki analogowe Wzorcowanie — Długość\n0 mm do 50 mm CMC 0,002 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) IW/LW1/12 Czujniki analogowe Wzorcowanie — Dlugosc\n0 mm do 50 mm CMC 0,002 mm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) IW/LW1/12","search_en":"Analogue dial indicators Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) IW/LW1/12","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"0,002 mm"}],"regulatory_area_de":"Länge","search_de":"Analoge Messuhren Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) IW/LW1/12","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"0,002 mm"}],"regulatory_area_zh":"长度","search_zh":"模拟指示表 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) IW/LW1/12","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"0,002 mm"}],"regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) IW/LW1/12","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry"},{"_id":"f01d8bc8d6f4ac6fa8c095f8","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Czujniki cyfrowe","test_object_en":"Digital indicators","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"0,002 mm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"0,002 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 50 mm CMC 0,002 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"IW/LW1/12","norm_bases":["IW/LW1/12"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Czujniki cyfrowe Wzorcowanie — Długość\n0 mm do 50 mm CMC 0,002 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) IW/LW1/12 Czujniki cyfrowe Wzorcowanie — Dlugosc\n0 mm do 50 mm CMC 0,002 mm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) IW/LW1/12","search_en":"Digital indicators Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) IW/LW1/12","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"0,002 mm"}],"regulatory_area_de":"Länge","search_de":"Digitale Messuhren Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) IW/LW1/12","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"0,002 mm"}],"regulatory_area_zh":"长度","search_zh":"数显指示表 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) IW/LW1/12","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"0,002 mm"}],"regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) IW/LW1/12","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry"},{"_id":"54c944a75d748953b743043b","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Mikrometry wewnętrzne","test_object_en":"Internal micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"5 mm do 30 mm","cmc":"1,6 µm"},{"name":"","range":"30 mm do 55 mm","cmc":"2,1 µm"}],"parameters_en":[{"name":"","range":"5 mm to 30 mm","cmc":"1,6 µm"},{"name":"","range":"30 mm to 55 mm","cmc":"2,1 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n5 mm do 30 mm CMC 1,6 µm\n30 mm do 55 mm CMC 2,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"IW/LW1/10","norm_bases":["IW/LW1/10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Mikrometry wewnętrzne Wzorcowanie — Długość\nZakres:\n5 mm do 30 mm CMC 1,6 µm\n30 mm do 55 mm CMC 2,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) IW/LW1/10 Mikrometry wewnetrzne Wzorcowanie — Dlugosc\nZakres:\n5 mm do 30 mm CMC 1,6 µm\n30 mm do 55 mm CMC 2,1 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) IW/LW1/10","search_en":"Internal micrometers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) IW/LW1/10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"5 mm to 30 mm","cmc":"1,6 µm"},{"name":"","range":"30 mm to 55 mm","cmc":"2,1 µm"}],"regulatory_area_de":"Länge","search_de":"Innenmessschrauben Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) IW/LW1/10","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Innenmessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"5 mm to 30 mm","cmc":"1,6 µm"},{"name":"","range":"30 mm to 55 mm","cmc":"2,1 µm"}],"regulatory_area_zh":"长度","search_zh":"内径千分尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) IW/LW1/10","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"内径千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"5 mm to 30 mm","cmc":"1,6 µm"},{"name":"","range":"30 mm to 55 mm","cmc":"2,1 µm"}],"regulatory_area_cs":"Délka","search_cs":"Vnitřní mikrometry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) IW/LW1/10","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Vnitřní mikrometry"},{"_id":"a2a736464257258baeb591e9","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Mikrometry zewnętrzne","test_object_en":"External micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 25 mm","cmc":"1,3 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,8 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"2,4 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"3,1 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"3,8 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"4,4 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"5,1 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"5,8 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,5 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"7,1 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"1,3 µm"},{"name":"","range":"25 mm to 50 mm","cmc":"1,8 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"2,4 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"3,1 µm"},{"name":"","range":"100 mm to 125 mm","cmc":"3,8 µm"},{"name":"","range":"125 mm to 150 mm","cmc":"4,4 µm"},{"name":"","range":"150 mm to 175 mm","cmc":"5,1 µm"},{"name":"","range":"175 mm to 200 mm","cmc":"5,8 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,5 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"7,1 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 1,3 µm\n25 mm do 50 mm CMC 1,8 µm\n50 mm do 75 mm CMC 2,4 µm\n75 mm do 100 mm CMC 3,1 µm\n100 mm do 125 mm CMC 3,8 µm\n125 mm do 150 mm CMC 4,4 µm\n150 mm do 175 mm CMC 5,1 µm\n175 mm do 200 mm CMC 5,8 µm\n200 mm do 225 mm CMC 6,5 µm\n225 mm do 250 mm CMC 7,1 µm\n250 mm do 275 mm CMC 7,9 µm\n275 mm do 300 mm CMC 8,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"IW/LW1/10","norm_bases":["IW/LW1/10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Mikrometry zewnętrzne Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 1,3 µm\n25 mm do 50 mm CMC 1,8 µm\n50 mm do 75 mm CMC 2,4 µm\n75 mm do 100 mm CMC 3,1 µm\n100 mm do 125 mm CMC 3,8 µm\n125 mm do 150 mm CMC 4,4 µm\n150 mm do 175 mm CMC 5,1 µm\n175 mm do 200 mm CMC 5,8 µm\n200 mm do 225 mm CMC 6,5 µm\n225 mm do 250 mm CMC 7,1 µm\n250 mm do 275 mm CMC 7,9 µm\n275 mm do 300 mm CMC 8,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) IW/LW1/10 Mikrometry zewnetrzne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 25 mm CMC 1,3 µm\n25 mm do 50 mm CMC 1,8 µm\n50 mm do 75 mm CMC 2,4 µm\n75 mm do 100 mm CMC 3,1 µm\n100 mm do 125 mm CMC 3,8 µm\n125 mm do 150 mm CMC 4,4 µm\n150 mm do 175 mm CMC 5,1 µm\n175 mm do 200 mm CMC 5,8 µm\n200 mm do 225 mm CMC 6,5 µm\n225 mm do 250 mm CMC 7,1 µm\n250 mm do 275 mm CMC 7,9 µm\n275 mm do 300 mm CMC 8,6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) IW/LW1/10","search_en":"External micrometers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) IW/LW1/10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 25 mm","cmc":"1,3 µm"},{"name":"","range":"25 mm bis 50 mm","cmc":"1,8 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"2,4 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"3,1 µm"},{"name":"","range":"100 mm bis 125 mm","cmc":"3,8 µm"},{"name":"","range":"125 mm bis 150 mm","cmc":"4,4 µm"},{"name":"","range":"150 mm bis 175 mm","cmc":"5,1 µm"},{"name":"","range":"175 mm bis 200 mm","cmc":"5,8 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,5 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"7,1 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,6 µm"}],"regulatory_area_de":"Länge","search_de":"Bügelmessschrauben Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) IW/LW1/10","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Bügelmessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"1,3 µm"},{"name":"","range":"25 mm 至 50 mm","cmc":"1,8 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"2,4 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"3,1 µm"},{"name":"","range":"100 mm 至 125 mm","cmc":"3,8 µm"},{"name":"","range":"125 mm 至 150 mm","cmc":"4,4 µm"},{"name":"","range":"150 mm 至 175 mm","cmc":"5,1 µm"},{"name":"","range":"175 mm 至 200 mm","cmc":"5,8 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,5 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"7,1 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,6 µm"}],"regulatory_area_zh":"长度","search_zh":"外径千分尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) IW/LW1/10","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"外径千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 25 mm","cmc":"1,3 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,8 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"2,4 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"3,1 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"3,8 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"4,4 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"5,1 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"5,8 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"6,5 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"7,1 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"7,9 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"8,6 µm"}],"regulatory_area_cs":"Délka","search_cs":"Mikrometry pro vnější měření Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) IW/LW1/10","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometry pro vnější měření"},{"_id":"49541a690aad03f541978c0a","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Płytki wzorcowe klasy 0, 1, 2 (stalowe)","test_object_en":"Gauge blocks of classes 0, 1, 2 (steel)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,5 mm do 100 mm","cmc":"Q[54; 1,23 ∙ L] nm"}],"parameters_en":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[54; 1,23 ∙ L] nm"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,5 mm do 100 mm CMC Q[54; 1,23 ∙ L] nm\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW1/05 w oparciu o PN-EN ISO 3650:2000","norm_bases":["IW/LW1/05","PN-EN ISO 3650:2000"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. L – wielkość mierzona (mm)","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. L – measured value (mm)","search_text":"Płytki wzorcowe klasy 0, 1, 2 (stalowe) Wzorcowanie — Długość\n0,5 mm do 100 mm CMC Q[54; 1,23 ∙ L] nm\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW1/05 w oparciu o PN-EN ISO 3650:2000 Plytki wzorcowe klasy 0, 1, 2 (stalowe) Wzorcowanie — Dlugosc\n0,5 mm do 100 mm CMC Q[54; 1,23 ∙ L] nm\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW1/05 w oparciu o PN-EN ISO 3650:2000","search_en":"Gauge blocks of classes 0, 1, 2 (steel) Calibration — Length Internal procedure; At permanent location (S) Length Internal procedure At permanent location (S) IW/LW1/05 based on PN-EN ISO 3650:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"IW/LW1/05 based on PN-EN ISO 3650:2000","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[54; 1,23 ∙ L] nm"}],"reference_de":"IW/LW1/05 auf Grundlage von PN-EN ISO 3650:2000","regulatory_area_de":"Länge","search_de":"Parallelendmaße der Klassen 0, 1, 2 (Stahl) Kalibrierung — Länge Internes Verfahren; Am festen Standort (S) Länge Internes Verfahren Am festen Standort (S) IW/LW1/05 auf Grundlage von PN-EN ISO 3650:2000","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Parallelendmaße der Klassen 0, 1, 2 (Stahl)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[54; 1,23 ∙ L] nm"}],"reference_zh":"IW/LW1/05 依据PN-EN ISO 3650:2000","regulatory_area_zh":"长度","search_zh":"0、1、2 级量块（钢制） 校准 — 长度 内部程序；在固定地点 (S) 长度 内部程序 在固定地点 (S) IW/LW1/05 依据PN-EN ISO 3650:2000","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"0、1、2 级量块（钢制）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[54; 1,23 ∙ L] nm"}],"reference_cs":"IW/LW1/05 na základě PN-EN ISO 3650:2000","regulatory_area_cs":"Délka","search_cs":"Koncové měrky třídy 0, 1, 2 (ocelové) Kalibrace — Délka Vnitřní postup; Ve stálé lokalitě (S) Délka Vnitřní postup Ve stálé lokalitě (S) IW/LW1/05 na základě PN-EN ISO 3650:2000","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky třídy 0, 1, 2 (ocelové)"},{"_id":"9bd0ff8fb21630b808a07918","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Płytki wzorcowe klasy 0, 1, 2 (ceramiczne)","test_object_en":"Gauge blocks of classes 0, 1, 2 (ceramic)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,5 mm do 100 mm","cmc":"Q[59; 1,17 ∙ L] nm"}],"parameters_en":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[59; 1,17 ∙ L] nm"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,5 mm do 100 mm CMC Q[59; 1,17 ∙ L] nm\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW1/05 w oparciu o PN-EN ISO 3650:2000","norm_bases":["IW/LW1/05","PN-EN ISO 3650:2000"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. L – wielkość mierzona (mm)","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. L – measured value (mm)","search_text":"Płytki wzorcowe klasy 0, 1, 2 (ceramiczne) Wzorcowanie — Długość\n0,5 mm do 100 mm CMC Q[59; 1,17 ∙ L] nm\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW1/05 w oparciu o PN-EN ISO 3650:2000 Plytki wzorcowe klasy 0, 1, 2 (ceramiczne) Wzorcowanie — Dlugosc\n0,5 mm do 100 mm CMC Q[59; 1,17 ∙ L] nm\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW1/05 w oparciu o PN-EN ISO 3650:2000","search_en":"Gauge blocks of classes 0, 1, 2 (ceramic) Calibration — Length Internal procedure; At permanent location (S) Length Internal procedure At permanent location (S) IW/LW1/05 based on PN-EN ISO 3650:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"IW/LW1/05 based on PN-EN ISO 3650:2000","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[59; 1,17 ∙ L] nm"}],"reference_de":"IW/LW1/05 auf Grundlage von PN-EN ISO 3650:2000","regulatory_area_de":"Länge","search_de":"Parallelendmaße der Klassen 0, 1, 2 (Keramik) Kalibrierung — Länge Internes Verfahren; Am festen Standort (S) Länge Internes Verfahren Am festen Standort (S) IW/LW1/05 auf Grundlage von PN-EN ISO 3650:2000","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Parallelendmaße der Klassen 0, 1, 2 (Keramik)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[59; 1,17 ∙ L] nm"}],"reference_zh":"IW/LW1/05 依据PN-EN ISO 3650:2000","regulatory_area_zh":"长度","search_zh":"0、1、2 级量块（陶瓷） 校准 — 长度 内部程序；在固定地点 (S) 长度 内部程序 在固定地点 (S) IW/LW1/05 依据PN-EN ISO 3650:2000","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"0、1、2 级量块（陶瓷）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[59; 1,17 ∙ L] nm"}],"reference_cs":"IW/LW1/05 na základě PN-EN ISO 3650:2000","regulatory_area_cs":"Délka","search_cs":"Koncové měrky třídy 0, 1, 2 (keramické) Kalibrace — Délka Vnitřní postup; Ve stálé lokalitě (S) Délka Vnitřní postup Ve stálé lokalitě (S) IW/LW1/05 na základě PN-EN ISO 3650:2000","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky třídy 0, 1, 2 (keramické)"},{"_id":"8745e8c693403bd705803e57","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Płytki wzorcowe klasy 0, 1, 2 (stalowe)","test_object_en":"Gauge blocks of classes 0, 1, 2 (steel)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"125 mm do 500 mm","cmc":"Q[68; 1,25 ∙ L] nm"}],"parameters_en":[{"name":"","range":"125 mm to 500 mm","cmc":"Q[68; 1,25 ∙ L] nm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza za pomocą komparatora dwuczujnikowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparison method using a two-probe comparator; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza za pomocą komparatora dwuczujnikowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparison method using a two-probe comparator","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n125 mm do 500 mm CMC Q[68; 1,25 ∙ L] nm\nProcedura wewnętrzna; Metoda porównawcza za pomocą komparatora dwuczujnikowego; W stałej lokalizacji (S)","reference":"IW/LW1/05","norm_bases":["IW/LW1/05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. L – wielkość mierzona (mm)","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. L – measured value (mm)","search_text":"Płytki wzorcowe klasy 0, 1, 2 (stalowe) Wzorcowanie — Długość\n125 mm do 500 mm CMC Q[68; 1,25 ∙ L] nm\nProcedura wewnętrzna; Metoda porównawcza za pomocą komparatora dwuczujnikowego; W stałej lokalizacji (S) IW/LW1/05 Plytki wzorcowe klasy 0, 1, 2 (stalowe) Wzorcowanie — Dlugosc\n125 mm do 500 mm CMC Q[68; 1,25 ∙ L] nm\nProcedura wewnetrzna; Metoda porownawcza za pomoca komparatora dwuczujnikowego; W stalej lokalizacji (S) IW/LW1/05","search_en":"Gauge blocks of classes 0, 1, 2 (steel) Calibration — Length Internal procedure; Comparison method using a two-probe comparator; At permanent location (S) Length Internal procedure Comparison method using a two-probe comparator At permanent location (S) IW/LW1/05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"125 mm to 500 mm","cmc":"Q[68; 1,25 ∙ L] nm"}],"regulatory_area_de":"Länge","search_de":"Parallelendmaße der Klassen 0, 1, 2 (Stahl) Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit Zweitaster-Komparator; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit Zweitaster-Komparator Am festen Standort (S) IW/LW1/05","technique_de":"Internes Verfahren; Vergleichsverfahren mit Zweitaster-Komparator; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit Zweitaster-Komparator","Am festen Standort (S)"],"test_object_de":"Parallelendmaße der Klassen 0, 1, 2 (Stahl)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"125 mm to 500 mm","cmc":"Q[68; 1,25 ∙ L] nm"}],"regulatory_area_zh":"长度","search_zh":"0、1、2 级量块（钢制） 校准 — 长度 内部程序; 使用双测头比较仪的比较法; 在固定地点 (S) 长度 内部程序 使用双测头比较仪的比较法 在固定地点 (S) IW/LW1/05","technique_zh":"内部程序; 使用双测头比较仪的比较法; 在固定地点 (S)","techniques_zh":["内部程序","使用双测头比较仪的比较法","在固定地点 (S)"],"test_object_zh":"0、1、2 级量块（钢制）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"125 mm to 500 mm","cmc":"Q[68; 1,25 ∙ L] nm"}],"regulatory_area_cs":"Délka","search_cs":"Koncové měrky třídy 0, 1, 2 (ocelové) Kalibrace — Délka Vnitřní postup; Srovnávací metoda pomocí dvoudotykového komparátoru; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda pomocí dvoudotykového komparátoru Ve stálé lokalitě (S) IW/LW1/05","technique_cs":"Vnitřní postup; Srovnávací metoda pomocí dvoudotykového komparátoru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda pomocí dvoudotykového komparátoru","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky třídy 0, 1, 2 (ocelové)"},{"_id":"73bb9bba9641fdd3566ed73e","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Płytki wzorcowe klasy 0, 1, 2 (ceramiczne)","test_object_en":"Gauge blocks of classes 0, 1, 2 (ceramic)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"125 mm do 500 mm","cmc":"Q[76; 2,04 ∙ L] nm"}],"parameters_en":[{"name":"","range":"125 mm to 500 mm","cmc":"Q[76; 2,04 ∙ L] nm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza za pomocą komparatora dwuczujnikowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparison method using a two-probe comparator; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza za pomocą komparatora dwuczujnikowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparison method using a two-probe comparator","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n125 mm do 500 mm CMC Q[76; 2,04 ∙ L] nm\nProcedura wewnętrzna; Metoda porównawcza za pomocą komparatora dwuczujnikowego; W stałej lokalizacji (S)","reference":"IW/LW1/05","norm_bases":["IW/LW1/05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. L – wielkość mierzona (mm)","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. L – measured value (mm)","search_text":"Płytki wzorcowe klasy 0, 1, 2 (ceramiczne) Wzorcowanie — Długość\n125 mm do 500 mm CMC Q[76; 2,04 ∙ L] nm\nProcedura wewnętrzna; Metoda porównawcza za pomocą komparatora dwuczujnikowego; W stałej lokalizacji (S) IW/LW1/05 Plytki wzorcowe klasy 0, 1, 2 (ceramiczne) Wzorcowanie — Dlugosc\n125 mm do 500 mm CMC Q[76; 2,04 ∙ L] nm\nProcedura wewnetrzna; Metoda porownawcza za pomoca komparatora dwuczujnikowego; W stalej lokalizacji (S) IW/LW1/05","search_en":"Gauge blocks of classes 0, 1, 2 (ceramic) Calibration — Length Internal procedure; Comparison method using a two-probe comparator; At permanent location (S) Length Internal procedure Comparison method using a two-probe comparator At permanent location (S) IW/LW1/05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"125 mm to 500 mm","cmc":"Q[76; 2,04 ∙ L] nm"}],"regulatory_area_de":"Länge","search_de":"Parallelendmaße der Klassen 0, 1, 2 (Keramik) Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit Zweitaster-Komparator; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit Zweitaster-Komparator Am festen Standort (S) IW/LW1/05","technique_de":"Internes Verfahren; Vergleichsverfahren mit Zweitaster-Komparator; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit Zweitaster-Komparator","Am festen Standort (S)"],"test_object_de":"Parallelendmaße der Klassen 0, 1, 2 (Keramik)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"125 mm to 500 mm","cmc":"Q[76; 2,04 ∙ L] nm"}],"regulatory_area_zh":"长度","search_zh":"0、1、2 级量块（陶瓷） 校准 — 长度 内部程序; 使用双测头比较仪的比较法; 在固定地点 (S) 长度 内部程序 使用双测头比较仪的比较法 在固定地点 (S) IW/LW1/05","technique_zh":"内部程序; 使用双测头比较仪的比较法; 在固定地点 (S)","techniques_zh":["内部程序","使用双测头比较仪的比较法","在固定地点 (S)"],"test_object_zh":"0、1、2 级量块（陶瓷）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"125 mm to 500 mm","cmc":"Q[76; 2,04 ∙ L] nm"}],"regulatory_area_cs":"Délka","search_cs":"Koncové měrky třídy 0, 1, 2 (keramické) Kalibrace — Délka Vnitřní postup; Srovnávací metoda pomocí dvoudotykového komparátoru; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda pomocí dvoudotykového komparátoru Ve stálé lokalitě (S) IW/LW1/05","technique_cs":"Vnitřní postup; Srovnávací metoda pomocí dvoudotykového komparátoru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda pomocí dvoudotykového komparátoru","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky třídy 0, 1, 2 (keramické)"},{"_id":"ad91648ae92bd416a0d98a4d","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Suwmiarki","test_object_en":"Calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 200 mm","cmc":"0,014 mm"},{"name":"","range":"0 mm do 300 mm","cmc":"0,015 mm"},{"name":"","range":"0 mm do 350 mm","cmc":"0,016 mm"},{"name":"","range":"0 mm do 400 mm","cmc":"0,017 mm"},{"name":"","range":"0 mm do 500 mm","cmc":"0,019 mm"},{"name":"","range":"0 mm do 600 mm","cmc":"0,021 mm"}],"parameters_en":[{"name":"","range":"0 mm to 200 mm","cmc":"0,014 mm"},{"name":"","range":"0 mm do 300 mm","cmc":"0,015 mm"},{"name":"","range":"0 mm do 350 mm","cmc":"0,016 mm"},{"name":"","range":"0 mm do 400 mm","cmc":"0,017 mm"},{"name":"","range":"0 mm do 500 mm","cmc":"0,019 mm"},{"name":"","range":"0 mm to 600 mm","cmc":"0,021 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 200 mm CMC 0,014 mm\n0 mm do 300 mm CMC 0,015 mm\n0 mm do 350 mm CMC 0,016 mm\n0 mm do 400 mm CMC 0,017 mm\n0 mm do 500 mm CMC 0,019 mm\n0 mm do 600 mm CMC 0,021 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"IW/LW1/09","norm_bases":["IW/LW1/09"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Suwmiarki Wzorcowanie — Długość\nZakres:\n0 mm do 200 mm CMC 0,014 mm\n0 mm do 300 mm CMC 0,015 mm\n0 mm do 350 mm CMC 0,016 mm\n0 mm do 400 mm CMC 0,017 mm\n0 mm do 500 mm CMC 0,019 mm\n0 mm do 600 mm CMC 0,021 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) IW/LW1/09 Suwmiarki Wzorcowanie — Dlugosc\nZakres:\n0 mm do 200 mm CMC 0,014 mm\n0 mm do 300 mm CMC 0,015 mm\n0 mm do 350 mm CMC 0,016 mm\n0 mm do 400 mm CMC 0,017 mm\n0 mm do 500 mm CMC 0,019 mm\n0 mm do 600 mm CMC 0,021 mm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) IW/LW1/09","search_en":"Calipers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) IW/LW1/09","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 200 mm","cmc":"0,014 mm"},{"name":"","range":"0 mm do 300 mm","cmc":"0,015 mm"},{"name":"","range":"0 mm do 350 mm","cmc":"0,016 mm"},{"name":"","range":"0 mm do 400 mm","cmc":"0,017 mm"},{"name":"","range":"0 mm do 500 mm","cmc":"0,019 mm"},{"name":"","range":"0 mm bis 600 mm","cmc":"0,021 mm"}],"regulatory_area_de":"Länge","search_de":"Messschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) IW/LW1/09","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Messschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 200 mm","cmc":"0,014 mm"},{"name":"","range":"0 mm do 300 mm","cmc":"0,015 mm"},{"name":"","range":"0 mm do 350 mm","cmc":"0,016 mm"},{"name":"","range":"0 mm do 400 mm","cmc":"0,017 mm"},{"name":"","range":"0 mm do 500 mm","cmc":"0,019 mm"},{"name":"","range":"0 mm 至 600 mm","cmc":"0,021 mm"}],"regulatory_area_zh":"长度","search_zh":"游标卡尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) IW/LW1/09","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 200 mm","cmc":"0,014 mm"},{"name":"","range":"0 mm do 300 mm","cmc":"0,015 mm"},{"name":"","range":"0 mm do 350 mm","cmc":"0,016 mm"},{"name":"","range":"0 mm do 400 mm","cmc":"0,017 mm"},{"name":"","range":"0 mm do 500 mm","cmc":"0,019 mm"},{"name":"","range":"0 mm do 600 mm","cmc":"0,021 mm"}],"regulatory_area_cs":"Délka","search_cs":"Posuvná měřidla Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) IW/LW1/09","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Posuvná měřidla"},{"_id":"a698fecf95fa426701694796","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Kątowniki 90° dwuramienne","test_object_en":"90° try squares","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"-prostopadłość kata prostego: zewnętrznego","range":"do 400 mm","cmc":"8 µm"},{"name":"-prostopadłość kata prostego: wewnętrznego","range":"do 400 mm","cmc":"9 µm"}],"parameters_en":[{"name":"squareness of the right angle: external","range":"up to 400 mm","cmc":"8 µm"},{"name":"squareness of the right angle: internal","range":"up to 400 mm","cmc":"9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\nZakres:\n-prostopadłość kata prostego: zewnętrznego do 400 mm CMC 8 µm\n-prostopadłość kata prostego: wewnętrznego do 400 mm CMC 9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"IW/LW1/02","norm_bases":["IW/LW1/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Kątowniki 90° dwuramienne Wzorcowanie — Kąt\nZakres:\n-prostopadłość kata prostego: zewnętrznego do 400 mm CMC 8 µm\n-prostopadłość kata prostego: wewnętrznego do 400 mm CMC 9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) IW/LW1/02 Katowniki 90° dwuramienne Wzorcowanie — Kat\nZakres:\n-prostopadlosc kata prostego: zewnetrznego do 400 mm CMC 8 µm\n-prostopadlosc kata prostego: wewnetrznego do 400 mm CMC 9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) IW/LW1/02","search_en":"90° try squares Calibration — Angle Internal procedure; Direct method using gauge blocks; At permanent location (S) Angle Internal procedure Direct method using gauge blocks At permanent location (S) squareness of the right angle: external squareness of the right angle: internal IW/LW1/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"-Rechtwinkligkeit des rechten Winkels: außen","range":"bis 400 mm","cmc":"8 µm"},{"name":"-Rechtwinkligkeit des rechten Winkels: innen","range":"bis 400 mm","cmc":"9 µm"}],"regulatory_area_de":"Winkel","search_de":"Zweischenklige 90°-Anschlagwinkel Kalibrierung — Winkel Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) -Rechtwinkligkeit des rechten Winkels: außen -Rechtwinkligkeit des rechten Winkels: innen IW/LW1/02","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Zweischenklige 90°-Anschlagwinkel","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"-直角垂直度：外角","range":"至 400 mm","cmc":"8 µm"},{"name":"-直角垂直度：内角","range":"至 400 mm","cmc":"9 µm"}],"regulatory_area_zh":"角度","search_zh":"90° 宽座直角尺 校准 — 角度 内部程序；使用量块的直接法；在固定地点 (S) 角度 内部程序 使用量块的直接法 在固定地点 (S) -直角垂直度：外角 -直角垂直度：内角 IW/LW1/02","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"90° 宽座直角尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"-kolmost pravého úhlu: vnějšího","range":"do 400 mm","cmc":"8 µm"},{"name":"-kolmost pravého úhlu: vnitřního","range":"do 400 mm","cmc":"9 µm"}],"regulatory_area_cs":"Úhel","search_cs":"Dvouramenné úhelníky 90° Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) -kolmost pravého úhlu: vnějšího -kolmost pravého úhlu: vnitřního IW/LW1/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Dvouramenné úhelníky 90°"},{"_id":"86017e315704ecdf0dfcdeb1","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Kątomierze uniwersalne analogowe","test_object_en":"Analogue universal bevel protractors","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"4 × 90°","cmc":"4′"}],"parameters_en":[{"name":"","range":"4 × 90°","cmc":"4′"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n4 × 90° CMC 4′\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek kątowych; W stałej lokalizacji (S)","reference":"IW/LW1/01","norm_bases":["IW/LW1/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Kątomierze uniwersalne analogowe Wzorcowanie — Kąt\n4 × 90° CMC 4′\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek kątowych; W stałej lokalizacji (S) IW/LW1/01 Katomierze uniwersalne analogowe Wzorcowanie — Kat\n4 × 90° CMC 4′\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek katowych; W stalej lokalizacji (S) IW/LW1/01","search_en":"Analogue universal bevel protractors Calibration — Angle Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Angle Internal procedure Direct method using angle gauge blocks At permanent location (S) IW/LW1/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Winkel","regulatory_area_de":"Winkel","search_de":"Analoge Universalwinkelmesser Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Winkelendmaßen Am festen Standort (S) IW/LW1/01","technique_de":"Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Analoge Universalwinkelmesser","methodology_zh":"校准 — 角度","regulatory_area_zh":"角度","search_zh":"模拟万能角度尺 校准 — 角度 内部程序；使用角度块的直接法；在固定地点 (S) 角度 内部程序 使用角度块的直接法 在固定地点 (S) IW/LW1/01","technique_zh":"内部程序；使用角度块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用角度块的直接法","在固定地点 (S)"],"test_object_zh":"模拟万能角度尺","methodology_cs":"Kalibrace — Úhel","regulatory_area_cs":"Úhel","search_cs":"Analogové univerzální úhloměry Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím úhlových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím úhlových měrek Ve stálé lokalitě (S) IW/LW1/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím úhlových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím úhlových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové univerzální úhloměry"},{"_id":"4c5eda63c42903e40dcd722e","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Kątomierze uniwersalne z odczytem cyfrowym","test_object_en":"Universal bevel protractors with digital readout","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 360°","cmc":"0,9′"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"0,9′"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 360° CMC 0,9′\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek kątowych; W stałej lokalizacji (S)","reference":"IW/LW1/01","norm_bases":["IW/LW1/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Kątomierze uniwersalne z odczytem cyfrowym Wzorcowanie — Kąt\n0° do 360° CMC 0,9′\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek kątowych; W stałej lokalizacji (S) IW/LW1/01 Katomierze uniwersalne z odczytem cyfrowym Wzorcowanie — Kat\n0° do 360° CMC 0,9′\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek katowych; W stalej lokalizacji (S) IW/LW1/01","search_en":"Universal bevel protractors with digital readout Calibration — Angle Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Angle Internal procedure Direct method using angle gauge blocks At permanent location (S) IW/LW1/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° bis 360°","cmc":"0,9′"}],"regulatory_area_de":"Winkel","search_de":"Universalwinkelmesser mit Digitalanzeige Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Winkelendmaßen Am festen Standort (S) IW/LW1/01","technique_de":"Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Universalwinkelmesser mit Digitalanzeige","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"0,9′"}],"regulatory_area_zh":"角度","search_zh":"数显万能角度尺 校准 — 角度 内部程序；使用角度块的直接法；在固定地点 (S) 角度 内部程序 使用角度块的直接法 在固定地点 (S) IW/LW1/01","technique_zh":"内部程序；使用角度块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用角度块的直接法","在固定地点 (S)"],"test_object_zh":"数显万能角度尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° do 360°","cmc":"0,9′"}],"regulatory_area_cs":"Úhel","search_cs":"Univerzální úhloměry s digitálním odečtem Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím úhlových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím úhlových měrek Ve stálé lokalitě (S) IW/LW1/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím úhlových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím úhlových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Univerzální úhloměry s digitálním odečtem"},{"_id":"cbcdc319a1fccacb592e130a","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Płytki kątowe Johanssona","test_object_en":"Johansson angle gauge blocks","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 360°","cmc":"3,8″"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"3,8″"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem goniometru; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using a goniometer; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem goniometru","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using a goniometer","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 360° CMC 3,8″\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem goniometru; W stałej lokalizacji (S)","reference":"IW/LW1/04","norm_bases":["IW/LW1/04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Płytki kątowe Johanssona Wzorcowanie — Kąt\n0° do 360° CMC 3,8″\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem goniometru; W stałej lokalizacji (S) IW/LW1/04 Plytki katowe Johanssona Wzorcowanie — Kat\n0° do 360° CMC 3,8″\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem goniometru; W stalej lokalizacji (S) IW/LW1/04","search_en":"Johansson angle gauge blocks Calibration — Angle Internal procedure; Indirect method using a goniometer; At permanent location (S) Angle Internal procedure Indirect method using a goniometer At permanent location (S) IW/LW1/04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° bis 360°","cmc":"3,8″"}],"regulatory_area_de":"Winkel","search_de":"Johansson-Winkelendmaße Kalibrierung — Winkel Internes Verfahren; Indirektes Verfahren mit Goniometer; Am festen Standort (S) Winkel Internes Verfahren Indirektes Verfahren mit Goniometer Am festen Standort (S) IW/LW1/04","technique_de":"Internes Verfahren; Indirektes Verfahren mit Goniometer; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit Goniometer","Am festen Standort (S)"],"test_object_de":"Johansson-Winkelendmaße","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"3,8″"}],"regulatory_area_zh":"角度","search_zh":"约翰逊角度块 校准 — 角度 内部程序; 使用测角仪的间接法; 在固定地点 (S) 角度 内部程序 使用测角仪的间接法 在固定地点 (S) IW/LW1/04","technique_zh":"内部程序; 使用测角仪的间接法; 在固定地点 (S)","techniques_zh":["内部程序","使用测角仪的间接法","在固定地点 (S)"],"test_object_zh":"约翰逊角度块","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° do 360°","cmc":"3,8″"}],"regulatory_area_cs":"Úhel","search_cs":"Úhlové měrky Johansson Kalibrace — Úhel Vnitřní postup; Nepřímá metoda s použitím goniometru; Ve stálé lokalitě (S) Úhel Vnitřní postup Nepřímá metoda s použitím goniometru Ve stálé lokalitě (S) IW/LW1/04","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím goniometru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím goniometru","Ve stálé lokalitě (S)"],"test_object_cs":"Úhlové měrky Johansson"},{"_id":"51a8af072b9e3ede1adec6e1","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Płytki kątowe Kusznikowa i przywieralne","test_object_en":"Kusznikow and wringing angle gauge blocks","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 360°","cmc":"3,8″"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"3,8″"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem goniometru; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using a goniometer; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem goniometru","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using a goniometer","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 360° CMC 3,8″\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem goniometru; W stałej lokalizacji (S)","reference":"IW/LW1/04","norm_bases":["IW/LW1/04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Płytki kątowe Kusznikowa i przywieralne Wzorcowanie — Kąt\n0° do 360° CMC 3,8″\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem goniometru; W stałej lokalizacji (S) IW/LW1/04 Plytki katowe Kusznikowa i przywieralne Wzorcowanie — Kat\n0° do 360° CMC 3,8″\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem goniometru; W stalej lokalizacji (S) IW/LW1/04","search_en":"Kusznikow and wringing angle gauge blocks Calibration — Angle Internal procedure; Indirect method using a goniometer; At permanent location (S) Angle Internal procedure Indirect method using a goniometer At permanent location (S) IW/LW1/04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° bis 360°","cmc":"3,8″"}],"regulatory_area_de":"Winkel","search_de":"Winkelendmaße nach Kuschnikow und ansprengbare Winkelendmaße Kalibrierung — Winkel Internes Verfahren; Indirektes Verfahren mit Goniometer; Am festen Standort (S) Winkel Internes Verfahren Indirektes Verfahren mit Goniometer Am festen Standort (S) IW/LW1/04","technique_de":"Internes Verfahren; Indirektes Verfahren mit Goniometer; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit Goniometer","Am festen Standort (S)"],"test_object_de":"Winkelendmaße nach Kuschnikow und ansprengbare Winkelendmaße","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"3,8″"}],"regulatory_area_zh":"角度","search_zh":"库什尼科夫角度块和研合式角度块 校准 — 角度 内部程序; 使用测角仪的间接法; 在固定地点 (S) 角度 内部程序 使用测角仪的间接法 在固定地点 (S) IW/LW1/04","technique_zh":"内部程序; 使用测角仪的间接法; 在固定地点 (S)","techniques_zh":["内部程序","使用测角仪的间接法","在固定地点 (S)"],"test_object_zh":"库什尼科夫角度块和研合式角度块","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° do 360°","cmc":"3,8″"}],"regulatory_area_cs":"Úhel","search_cs":"Úhlové měrky Kušnikova a přilnavé Kalibrace — Úhel Vnitřní postup; Nepřímá metoda s použitím goniometru; Ve stálé lokalitě (S) Úhel Vnitřní postup Nepřímá metoda s použitím goniometru Ve stálé lokalitě (S) IW/LW1/04","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím goniometru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím goniometru","Ve stálé lokalitě (S)"],"test_object_cs":"Úhlové měrky Kušnikova a přilnavé"},{"_id":"7651ebc5e5b93b20d68f2fd9","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Profilometry stykowe","test_object_en":"Contact profilometers","methodology":"Wzorcowanie — Długość (geometria powierzchni)","methodology_en":"Calibration — Length (surface geometry)","parameters":[{"name":"","range":"Ra=0,446 µm","cmc":"0,031 µm"},{"name":"","range":"Rz=1,201 µm","cmc":"0,229 µm"},{"name":"","range":"Ra=0,621 µm","cmc":"0,035 µm"},{"name":"","range":"Rz=1,777 µm","cmc":"0,190 µm"},{"name":"","range":"Ra=2,593 µm","cmc":"0,081 µm"},{"name":"","range":"Rz=8,89 µm","cmc":"0,284 µm"},{"name":"","range":"Ra=5,91 µm","cmc":"0,191 µm"},{"name":"","range":"Rz=22,07 µm","cmc":"1,647 µm"}],"parameters_en":[{"name":"","range":"Ra=0,446 µm","cmc":"0,031 µm"},{"name":"","range":"Rz=1,201 µm","cmc":"0,229 µm"},{"name":"","range":"Ra=0,621 µm","cmc":"0,035 µm"},{"name":"","range":"Rz=1,777 µm","cmc":"0,190 µm"},{"name":"","range":"Ra=2,593 µm","cmc":"0,081 µm"},{"name":"","range":"Rz=8,89 µm","cmc":"0,284 µm"},{"name":"","range":"Ra=5,91 µm","cmc":"0,191 µm"},{"name":"","range":"Rz=22,07 µm","cmc":"1,647 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem wzorców chropowatości; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using roughness specimens; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem wzorców chropowatości","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using roughness specimens","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (geometria powierzchni)\nZakres:\nRa=0,446 µm CMC 0,031 µm\nRz=1,201 µm CMC 0,229 µm\nRa=0,621 µm CMC 0,035 µm\nRz=1,777 µm CMC 0,190 µm\nRa=2,593 µm CMC 0,081 µm\nRz=8,89 µm CMC 0,284 µm\nRa=5,91 µm CMC 0,191 µm\nRz=22,07 µm CMC 1,647 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem wzorców chropowatości; W stałej lokalizacji (S)","reference":"IW/LW1/16","norm_bases":["IW/LW1/16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (geometria powierzchni)","regulatory_area_en":"Length (surface geometry)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Profilometry stykowe Wzorcowanie — Długość (geometria powierzchni)\nZakres:\nRa=0,446 µm CMC 0,031 µm\nRz=1,201 µm CMC 0,229 µm\nRa=0,621 µm CMC 0,035 µm\nRz=1,777 µm CMC 0,190 µm\nRa=2,593 µm CMC 0,081 µm\nRz=8,89 µm CMC 0,284 µm\nRa=5,91 µm CMC 0,191 µm\nRz=22,07 µm CMC 1,647 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem wzorców chropowatości; W stałej lokalizacji (S) IW/LW1/16 Profilometry stykowe Wzorcowanie — Dlugosc (geometria powierzchni)\nZakres:\nRa=0,446 µm CMC 0,031 µm\nRz=1,201 µm CMC 0,229 µm\nRa=0,621 µm CMC 0,035 µm\nRz=1,777 µm CMC 0,190 µm\nRa=2,593 µm CMC 0,081 µm\nRz=8,89 µm CMC 0,284 µm\nRa=5,91 µm CMC 0,191 µm\nRz=22,07 µm CMC 1,647 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem wzorcow chropowatosci; W stalej lokalizacji (S) IW/LW1/16","search_en":"Contact profilometers Calibration — Length (surface geometry) Internal procedure; Direct method using roughness specimens; At permanent location (S) Length (surface geometry) Internal procedure Direct method using roughness specimens At permanent location (S) IW/LW1/16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Oberflächengeometrie)","regulatory_area_de":"Länge (Oberflächengeometrie)","search_de":"Taktile Profilometer Kalibrierung — Länge (Oberflächengeometrie) Internes Verfahren; Direktes Verfahren mit Rauheitsnormalen; Am festen Standort (S) Länge (Oberflächengeometrie) Internes Verfahren Direktes Verfahren mit Rauheitsnormalen Am festen Standort (S) IW/LW1/16","technique_de":"Internes Verfahren; Direktes Verfahren mit Rauheitsnormalen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Rauheitsnormalen","Am festen Standort (S)"],"test_object_de":"Taktile Profilometer","methodology_zh":"校准 — 长度（表面几何）","regulatory_area_zh":"长度（表面几何）","search_zh":"接触式轮廓仪 校准 — 长度（表面几何） 内部程序；使用粗糙度标准样块的直接法；在固定地点 (S) 长度（表面几何） 内部程序 使用粗糙度标准样块的直接法 在固定地点 (S) IW/LW1/16","technique_zh":"内部程序；使用粗糙度标准样块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用粗糙度标准样块的直接法","在固定地点 (S)"],"test_object_zh":"接触式轮廓仪","methodology_cs":"Kalibrace — Délka (geometrie povrchu)","regulatory_area_cs":"Délka (geometrie povrchu)","search_cs":"Dotykové profiloměry Kalibrace — Délka (geometrie povrchu) Vnitřní postup; Přímá metoda s použitím etalonů drsnosti; Ve stálé lokalitě (S) Délka (geometrie povrchu) Vnitřní postup Přímá metoda s použitím etalonů drsnosti Ve stálé lokalitě (S) IW/LW1/16","technique_cs":"Vnitřní postup; Přímá metoda s použitím etalonů drsnosti; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím etalonů drsnosti","Ve stálé lokalitě (S)"],"test_object_cs":"Dotykové profiloměry"},{"_id":"6e560d2189bb09eb8ff821e3","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Wzorce chropowatości typu C i D","test_object_en":"Roughness specimens of types C and D","methodology":"Wzorcowanie — Długość (geometria powierzchni)","methodology_en":"Calibration — Length (surface geometry)","parameters":[{"name":"Rₐ","range":"0,05 µm do 30 µm","cmc":"Q[0,054; 0,039 · Rₐ]"},{"name":"Rₚ, Rᵥ, R_z, Rₜ","range":"0,05 µm do 30 µm","cmc":"Q[0,09; 0,055 · R]"}],"parameters_en":[{"name":"Rₐ","range":"0,05 µm to 30 µm","cmc":"Q[0,054; 0,039 · Rₐ]"},{"name":"Rₚ, Rᵥ, R_z, Rₜ","range":"0,05 µm to 30 µm","cmc":"Q[0,09; 0,055 · R]"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem profilometru stykowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using a contact profilometer; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem profilometru stykowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using a contact profilometer","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (geometria powierzchni)\nZakres:\nRₐ 0,05 µm do 30 µm CMC Q[0,054; 0,039 · Rₐ]\nRₚ, Rᵥ, R_z, Rₜ 0,05 µm do 30 µm CMC Q[0,09; 0,055 · R]\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem profilometru stykowego; W stałej lokalizacji (S)","reference":"IW/LW1/14","norm_bases":["IW/LW1/14"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (geometria powierzchni)","regulatory_area_en":"Length (surface geometry)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. Rₐ –wielkość mierzona (µm); Rₚ, Rᵥ, R_z, Rₜ – wielkości mierzone (µm)","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. Rₐ – measured value (µm); Rₚ, Rᵥ, R_z, Rₜ – measured values (µm)","search_text":"Wzorce chropowatości typu C i D Wzorcowanie — Długość (geometria powierzchni)\nZakres:\nRₐ 0,05 µm do 30 µm CMC Q[0,054; 0,039 · Rₐ]\nRₚ, Rᵥ, R_z, Rₜ 0,05 µm do 30 µm CMC Q[0,09; 0,055 · R]\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem profilometru stykowego; W stałej lokalizacji (S) IW/LW1/14 Wzorce chropowatosci typu C i D Wzorcowanie — Dlugosc (geometria powierzchni)\nZakres:\nRₐ 0,05 µm do 30 µm CMC Q[0,054; 0,039 · Rₐ]\nRₚ, Rᵥ, R_z, Rₜ 0,05 µm do 30 µm CMC Q[0,09; 0,055 · R]\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem profilometru stykowego; W stalej lokalizacji (S) IW/LW1/14","search_en":"Roughness specimens of types C and D Calibration — Length (surface geometry) Internal procedure; Indirect method using a contact profilometer; At permanent location (S) Length (surface geometry) Internal procedure Indirect method using a contact profilometer At permanent location (S) Rₐ Rₚ, Rᵥ, R_z, Rₜ IW/LW1/14","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge (Oberflächengeometrie)","parameters_de":[{"name":"Rₐ","range":"0,05 µm to 30 µm","cmc":"Q[0,054; 0,039 · Rₐ]"},{"name":"Rₚ, Rᵥ, R_z, Rₜ","range":"0,05 µm to 30 µm","cmc":"Q[0,09; 0,055 · R]"}],"regulatory_area_de":"Länge (Oberflächengeometrie)","search_de":"Rauheitsnormale Typ C und D Kalibrierung — Länge (Oberflächengeometrie) Internes Verfahren; Indirektes Verfahren mit taktilem Profilometer; Am festen Standort (S) Länge (Oberflächengeometrie) Internes Verfahren Indirektes Verfahren mit taktilem Profilometer Am festen Standort (S) Rₐ Rₚ, Rᵥ, R_z, Rₜ IW/LW1/14","technique_de":"Internes Verfahren; Indirektes Verfahren mit taktilem Profilometer; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit taktilem Profilometer","Am festen Standort (S)"],"test_object_de":"Rauheitsnormale Typ C und D","methodology_zh":"校准 — 长度（表面几何）","parameters_zh":[{"name":"Rₐ","range":"0,05 µm to 30 µm","cmc":"Q[0,054; 0,039 · Rₐ]"},{"name":"Rₚ, Rᵥ, R_z, Rₜ","range":"0,05 µm to 30 µm","cmc":"Q[0,09; 0,055 · R]"}],"regulatory_area_zh":"长度（表面几何）","search_zh":"C 型和 D 型粗糙度标准样块 校准 — 长度（表面几何） 内部程序; 使用接触式轮廓仪的间接法; 在固定地点 (S) 长度（表面几何） 内部程序 使用接触式轮廓仪的间接法 在固定地点 (S) Rₐ Rₚ, Rᵥ, R_z, Rₜ IW/LW1/14","technique_zh":"内部程序; 使用接触式轮廓仪的间接法; 在固定地点 (S)","techniques_zh":["内部程序","使用接触式轮廓仪的间接法","在固定地点 (S)"],"test_object_zh":"C 型和 D 型粗糙度标准样块","methodology_cs":"Kalibrace — Délka (geometrie povrchu)","parameters_cs":[{"name":"Rₐ","range":"0,05 µm to 30 µm","cmc":"Q[0,054; 0,039 · Rₐ]"},{"name":"Rₚ, Rᵥ, R_z, Rₜ","range":"0,05 µm to 30 µm","cmc":"Q[0,09; 0,055 · R]"}],"regulatory_area_cs":"Délka (geometrie povrchu)","search_cs":"Etalony drsnosti typu C a D Kalibrace — Délka (geometrie povrchu) Vnitřní postup; Nepřímá metoda s použitím dotykového profilometru; Ve stálé lokalitě (S) Délka (geometrie povrchu) Vnitřní postup Nepřímá metoda s použitím dotykového profilometru Ve stálé lokalitě (S) Rₐ Rₚ, Rᵥ, R_z, Rₜ IW/LW1/14","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím dotykového profilometru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím dotykového profilometru","Ve stálé lokalitě (S)"],"test_object_cs":"Etalony drsnosti typu C a D"},{"_id":"6c4ba7c55aa4610508cae7d8","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Higrometry\nTermohigrometry","test_object_en":"Hygrometers\nThermohygrometers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"10 °C; 50 %rh do 85 %rh","range":"50 %rh","cmc":"0,8 %rh"},{"name":"10 °C; 50 %rh do 85 %rh","range":"85 %rh","cmc":"1,5 %rh"},{"name":"20 °C do 23 °C; 20 %rh do 85 %rh","range":"20 %rh","cmc":"0,5 %rh"},{"name":"20 °C do 23 °C; 20 %rh do 85 %rh","range":"85 %rh","cmc":"1,4 %rh"},{"name":"40 °C; 20 %rh do 60 %rh","range":"20 %rh","cmc":"0,7 %rh"},{"name":"40 °C; 20 %rh do 60 %rh","range":"60 %rh","cmc":"1,3 %rh"}],"parameters_en":[{"name":"10 °C; 50 %rh to 85 %rh","range":"50 %rh","cmc":"0,8 %rh"},{"name":"10 °C; 50 %rh to 85 %rh","range":"85 %rh","cmc":"1,5 %rh"},{"name":"20 °C to 23 °C; 20 %rh to 85 %rh","range":"20 %rh","cmc":"0,5 %rh"},{"name":"20 °C to 23 °C; 20 %rh to 85 %rh","range":"85 %rh","cmc":"1,4 %rh"},{"name":"40 °C; 20 %rh to 60 %rh","range":"20 %rh","cmc":"0,7 %rh"},{"name":"40 °C; 20 %rh to 60 %rh","range":"60 %rh","cmc":"1,3 %rh"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nZakres:\n10 °C; 50 %rh do 85 %rh 50 %rh CMC 0,8 %rh\n10 °C; 50 %rh do 85 %rh 85 %rh CMC 1,5 %rh\n20 °C do 23 °C; 20 %rh do 85 %rh 20 %rh CMC 0,5 %rh\n20 °C do 23 °C; 20 %rh do 85 %rh 85 %rh CMC 1,4 %rh\n40 °C; 20 %rh do 60 %rh 20 %rh CMC 0,7 %rh\n40 °C; 20 %rh do 60 %rh 60 %rh CMC 1,3 %rh\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"IW/LW1/15","norm_bases":["IW/LW1/15"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Higrometry\nTermohigrometry Wzorcowanie — Wilgotność względna\nZakres:\n10 °C; 50 %rh do 85 %rh 50 %rh CMC 0,8 %rh\n10 °C; 50 %rh do 85 %rh 85 %rh CMC 1,5 %rh\n20 °C do 23 °C; 20 %rh do 85 %rh 20 %rh CMC 0,5 %rh\n20 °C do 23 °C; 20 %rh do 85 %rh 85 %rh CMC 1,4 %rh\n40 °C; 20 %rh do 60 %rh 20 %rh CMC 0,7 %rh\n40 °C; 20 %rh do 60 %rh 60 %rh CMC 1,3 %rh\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) IW/LW1/15 Higrometry\nTermohigrometry Wzorcowanie — Wilgotnosc wzgledna\nZakres:\n10 °C; 50 %rh do 85 %rh 50 %rh CMC 0,8 %rh\n10 °C; 50 %rh do 85 %rh 85 %rh CMC 1,5 %rh\n20 °C do 23 °C; 20 %rh do 85 %rh 20 %rh CMC 0,5 %rh\n20 °C do 23 °C; 20 %rh do 85 %rh 85 %rh CMC 1,4 %rh\n40 °C; 20 %rh do 60 %rh 20 %rh CMC 0,7 %rh\n40 °C; 20 %rh do 60 %rh 60 %rh CMC 1,3 %rh\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) IW/LW1/15","search_en":"Hygrometers Thermohygrometers Calibration — Relative humidity Internal procedure; Indirect method; At permanent location (S) Relative humidity Internal procedure Indirect method At permanent location (S) 10 °C; 50 %rh to 85 %rh 10 °C; 50 %rh to 85 %rh 20 °C to 23 °C; 20 %rh to 85 %rh 20 °C to 23 °C; 20 %rh to 85 %rh 40 °C; 20 %rh to 60 %rh 40 °C; 20 %rh to 60 %rh IW/LW1/15","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"10 °C; 50 %rh bis 85 %rh","range":"50 %rh","cmc":"0,8 %rh"},{"name":"10 °C; 50 %rh bis 85 %rh","range":"85 %rh","cmc":"1,5 %rh"},{"name":"20 °C bis 23 °C; 20 %rh bis 85 %rh","range":"20 %rh","cmc":"0,5 %rh"},{"name":"20 °C bis 23 °C; 20 %rh bis 85 %rh","range":"85 %rh","cmc":"1,4 %rh"},{"name":"40 °C; 20 %rh bis 60 %rh","range":"20 %rh","cmc":"0,7 %rh"},{"name":"40 °C; 20 %rh bis 60 %rh","range":"60 %rh","cmc":"1,3 %rh"}],"regulatory_area_de":"Relative Feuchte","search_de":"Hygrometer Thermohygrometer Kalibrierung — Relative Feuchte Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Relative Feuchte Internes Verfahren Indirektes Verfahren Am festen Standort (S) 10 °C; 50 %rh bis 85 %rh 10 °C; 50 %rh bis 85 %rh 20 °C bis 23 °C; 20 %rh bis 85 %rh 20 °C bis 23 °C; 20 %rh bis 85 %rh 40 °C; 20 %rh bis 60 %rh 40 °C; 20 %rh bis 60 %rh IW/LW1/15","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Hygrometer\nThermohygrometer","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"10 °C; 50 %rh 至 85 %rh","range":"50 %rh","cmc":"0,8 %rh"},{"name":"10 °C; 50 %rh 至 85 %rh","range":"85 %rh","cmc":"1,5 %rh"},{"name":"20 °C 至 23 °C; 20 %rh 至 85 %rh","range":"20 %rh","cmc":"0,5 %rh"},{"name":"20 °C 至 23 °C; 20 %rh 至 85 %rh","range":"85 %rh","cmc":"1,4 %rh"},{"name":"40 °C; 20 %rh 至 60 %rh","range":"20 %rh","cmc":"0,7 %rh"},{"name":"40 °C; 20 %rh 至 60 %rh","range":"60 %rh","cmc":"1,3 %rh"}],"regulatory_area_zh":"相对湿度","search_zh":"湿度计 温湿度计 校准 — 相对湿度 内部程序；间接方法；固定地点（S） 相对湿度 内部程序 间接法 在固定地点 (S) 10 °C; 50 %rh 至 85 %rh 10 °C; 50 %rh 至 85 %rh 20 °C 至 23 °C; 20 %rh 至 85 %rh 20 °C 至 23 °C; 20 %rh 至 85 %rh 40 °C; 20 %rh 至 60 %rh 40 °C; 20 %rh 至 60 %rh IW/LW1/15","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"湿度计\n温湿度计","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"10 °C; 50 %rh až 85 %rh","range":"50 %rh","cmc":"0,8 %rh"},{"name":"10 °C; 50 %rh až 85 %rh","range":"85 %rh","cmc":"1,5 %rh"},{"name":"20 °C až 23 °C; 20 %rh až 85 %rh","range":"20 %rh","cmc":"0,5 %rh"},{"name":"20 °C až 23 °C; 20 %rh až 85 %rh","range":"85 %rh","cmc":"1,4 %rh"},{"name":"40 °C; 20 %rh až 60 %rh","range":"20 %rh","cmc":"0,7 %rh"},{"name":"40 °C; 20 %rh až 60 %rh","range":"60 %rh","cmc":"1,3 %rh"}],"regulatory_area_cs":"Relativní vlhkost","search_cs":"Vlhkoměry Termohygrometry Kalibrace — Relativní vlhkost Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Relativní vlhkost Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) 10 °C; 50 %rh až 85 %rh 10 °C; 50 %rh až 85 %rh 20 °C až 23 °C; 20 %rh až 85 %rh 20 °C až 23 °C; 20 %rh až 85 %rh 40 °C; 20 %rh až 60 %rh 40 °C; 20 %rh až 60 %rh IW/LW1/15","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Vlhkoměry\nTermohygrometry"},{"_id":"44621a356c2ef00014a085fe","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Ciśnieniomierze obciążnikowo-tłokowe\n- ciśnienie względne (ciecz)","test_object_en":"Piston gauges\n- gauge pressure (liquid)","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"0,02 MPa do 60 MPa","cmc":"2,5 · 10⁻⁴ · p"}],"parameters_en":[{"name":"","range":"0,02 MPa to 60 MPa","cmc":"2,5 · 10⁻⁴ · p"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\n0,02 MPa do 60 MPa CMC 2,5 · 10⁻⁴ · p\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW1/11","norm_bases":["IW/LW1/11"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. gdzie p – ciśnienie mierzone","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. where p – measured pressure","search_text":"Ciśnieniomierze obciążnikowo-tłokowe\n- ciśnienie względne (ciecz) Wzorcowanie — Ciśnienie\n0,02 MPa do 60 MPa CMC 2,5 · 10⁻⁴ · p\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW1/11 Cisnieniomierze obciaznikowo-tlokowe\n- cisnienie wzgledne (ciecz) Wzorcowanie — Cisnienie\n0,02 MPa do 60 MPa CMC 2,5 · 10⁻⁴ · p\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW1/11","search_en":"Piston gauges - gauge pressure (liquid) Calibration — Pressure Internal procedure; At permanent location (S) Pressure Internal procedure At permanent location (S) IW/LW1/11","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"0,02 MPa to 60 MPa","cmc":"2,5 · 10⁻⁴ · p"}],"regulatory_area_de":"Druck","search_de":"Kolbenmanometer (Druckwaagen) - Überdruck (Flüssigkeit) Kalibrierung — Druck Internes Verfahren; Am festen Standort (S) Druck Internes Verfahren Am festen Standort (S) IW/LW1/11","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kolbenmanometer (Druckwaagen)\n- Überdruck (Flüssigkeit)","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"0,02 MPa to 60 MPa","cmc":"2,5 · 10⁻⁴ · p"}],"regulatory_area_zh":"压力","search_zh":"活塞式压力计 - 表压（液体） 校准 — 压力 内部程序；在固定地点 (S) 压力 内部程序 在固定地点 (S) IW/LW1/11","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"活塞式压力计\n- 表压（液体）","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"0,02 MPa to 60 MPa","cmc":"2,5 · 10⁻⁴ · p"}],"regulatory_area_cs":"Tlak","search_cs":"Pístové tlakoměry se závažím - přetlak (kapalina) Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) Tlak Vnitřní postup Ve stálé lokalitě (S) IW/LW1/11","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Pístové tlakoměry se závažím\n- přetlak (kapalina)"},{"_id":"52e1d61ac3ce3ff4852b75ca","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\n- ciśnienie względne (gaz)","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\n- gauge pressure (gas)","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"-0,05 MPa do -0,001 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"-0,1 MPa do -0,05 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"0,001 MPa do 0,14 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"0,15 MPa do 0,2 MPa","cmc":"2 · 10⁻⁵ MPa"},{"name":"","range":"0,2 MPa do 1 MPa","cmc":"1 · 10⁻⁴ MPa"}],"parameters_en":[{"name":"","range":"-0,05 MPa to -0,001 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"-0,1 MPa to -0,05 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"0,001 MPa to 0,14 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"0,15 MPa to 0,2 MPa","cmc":"2 · 10⁻⁵ MPa"},{"name":"","range":"0,2 MPa to 1 MPa","cmc":"1 · 10⁻⁴ MPa"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n-0,05 MPa do -0,001 MPa CMC 1 · 10⁻⁵ MPa\n-0,1 MPa do -0,05 MPa CMC 1 · 10⁻⁵ MPa\n0,001 MPa do 0,14 MPa CMC 1 · 10⁻⁵ MPa\n0,15 MPa do 0,2 MPa CMC 2 · 10⁻⁵ MPa\n0,2 MPa do 1 MPa CMC 1 · 10⁻⁴ MPa\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW1/08","norm_bases":["IW/LW1/08"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\n- ciśnienie względne (gaz) Wzorcowanie — Ciśnienie\nZakres:\n-0,05 MPa do -0,001 MPa CMC 1 · 10⁻⁵ MPa\n-0,1 MPa do -0,05 MPa CMC 1 · 10⁻⁵ MPa\n0,001 MPa do 0,14 MPa CMC 1 · 10⁻⁵ MPa\n0,15 MPa do 0,2 MPa CMC 2 · 10⁻⁵ MPa\n0,2 MPa do 1 MPa CMC 1 · 10⁻⁴ MPa\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW1/08 Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\n- cisnienie wzgledne (gaz) Wzorcowanie — Cisnienie\nZakres:\n-0,05 MPa do -0,001 MPa CMC 1 · 10⁻⁵ MPa\n-0,1 MPa do -0,05 MPa CMC 1 · 10⁻⁵ MPa\n0,001 MPa do 0,14 MPa CMC 1 · 10⁻⁵ MPa\n0,15 MPa do 0,2 MPa CMC 2 · 10⁻⁵ MPa\n0,2 MPa do 1 MPa CMC 1 · 10⁻⁴ MPa\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW1/08","search_en":"Bourdon tube pressure gauges Electronic pressure gauges - gauge pressure (gas) Calibration — Pressure Internal procedure; At permanent location (S) Pressure Internal procedure At permanent location (S) IW/LW1/08","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":19,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"-0,05 MPa to -0,001 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"-0,1 MPa to -0,05 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"0,001 MPa to 0,14 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"0,15 MPa to 0,2 MPa","cmc":"2 · 10⁻⁵ MPa"},{"name":"","range":"0,2 MPa to 1 MPa","cmc":"1 · 10⁻⁴ MPa"}],"regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte - Überdruck (Gas) Kalibrierung — Druck Internes Verfahren; Am festen Standort (S) Druck Internes Verfahren Am festen Standort (S) IW/LW1/08","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\n- Überdruck (Gas)","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"-0,05 MPa to -0,001 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"-0,1 MPa to -0,05 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"0,001 MPa to 0,14 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"0,15 MPa to 0,2 MPa","cmc":"2 · 10⁻⁵ MPa"},{"name":"","range":"0,2 MPa to 1 MPa","cmc":"1 · 10⁻⁴ MPa"}],"regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 - 表压（气体） 校准 — 压力 内部程序；在固定地点 (S) 压力 内部程序 在固定地点 (S) IW/LW1/08","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"弹簧管压力表\n电子压力计\n- 表压（气体）","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"-0,05 MPa to -0,001 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"-0,1 MPa to -0,05 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"0,001 MPa to 0,14 MPa","cmc":"1 · 10⁻⁵ MPa"},{"name":"","range":"0,15 MPa to 0,2 MPa","cmc":"2 · 10⁻⁵ MPa"},{"name":"","range":"0,2 MPa to 1 MPa","cmc":"1 · 10⁻⁴ MPa"}],"regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry - přetlak (plyn) Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) Tlak Vnitřní postup Ve stálé lokalitě (S) IW/LW1/08","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\n- přetlak (plyn)"},{"_id":"2bab05d7591218e4ad788cfc","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\n- ciśnienie względne (ciecz)","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\n- gauge pressure (liquid)","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"0,02 MPa do 0,4 MPa","cmc":"1 · 10⁻⁴ MPa"},{"name":"","range":"0,4 MPa do 1 MPa","cmc":"4 · 10⁻⁴ MPa"},{"name":"","range":"1 MPa do 3 MPa","cmc":"1 · 10⁻³ MPa"},{"name":"","range":"3 MPa do 4 MPa","cmc":"2 · 10⁻³ MPa"},{"name":"","range":"4 MPa do 6 MPa","cmc":"4 · 10⁻³ MPa"},{"name":"","range":"6 MPa do 10 MPa","cmc":"5 · 10⁻³ MPa"},{"name":"","range":"10 MPa do 27 MPa","cmc":"1 · 10⁻² MPa"},{"name":"","range":"28 MPa do 60 MPa","cmc":"2 · 10⁻² MPa"},{"name":"","range":"60 MPa do 100 MPa","cmc":"6 · 10⁻² MPa"},{"name":"","range":"100 MPa do 200 MPa","cmc":"1 · 10⁻¹ MPa"},{"name":"","range":"210 MPa do 250 MPa","cmc":"3 · 10⁻¹ MPa"}],"parameters_en":[{"name":"","range":"0,02 MPa to 0,4 MPa","cmc":"1 · 10⁻⁴ MPa"},{"name":"","range":"0,4 MPa to 1 MPa","cmc":"4 · 10⁻⁴ MPa"},{"name":"","range":"1 MPa to 3 MPa","cmc":"1 · 10⁻³ MPa"},{"name":"","range":"3 MPa to 4 MPa","cmc":"2 · 10⁻³ MPa"},{"name":"","range":"4 MPa to 6 MPa","cmc":"4 · 10⁻³ MPa"},{"name":"","range":"6 MPa to 10 MPa","cmc":"5 · 10⁻³ MPa"},{"name":"","range":"10 MPa to 27 MPa","cmc":"1 · 10⁻² MPa"},{"name":"","range":"28 MPa to 60 MPa","cmc":"2 · 10⁻² MPa"},{"name":"","range":"60 MPa to 100 MPa","cmc":"6 · 10⁻² MPa"},{"name":"","range":"100 MPa to 200 MPa","cmc":"1 · 10⁻¹ MPa"},{"name":"","range":"210 MPa to 250 MPa","cmc":"3 · 10⁻¹ MPa"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n0,02 MPa do 0,4 MPa CMC 1 · 10⁻⁴ MPa\n0,4 MPa do 1 MPa CMC 4 · 10⁻⁴ MPa\n1 MPa do 3 MPa CMC 1 · 10⁻³ MPa\n3 MPa do 4 MPa CMC 2 · 10⁻³ MPa\n4 MPa do 6 MPa CMC 4 · 10⁻³ MPa\n6 MPa do 10 MPa CMC 5 · 10⁻³ MPa\n10 MPa do 27 MPa CMC 1 · 10⁻² MPa\n28 MPa do 60 MPa CMC 2 · 10⁻² MPa\n60 MPa do 100 MPa CMC 6 · 10⁻² MPa\n100 MPa do 200 MPa CMC 1 · 10⁻¹ MPa\n210 MPa do 250 MPa CMC 3 · 10⁻¹ MPa\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW1/08","norm_bases":["IW/LW1/08"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\n- ciśnienie względne (ciecz) Wzorcowanie — Ciśnienie\nZakres:\n0,02 MPa do 0,4 MPa CMC 1 · 10⁻⁴ MPa\n0,4 MPa do 1 MPa CMC 4 · 10⁻⁴ MPa\n1 MPa do 3 MPa CMC 1 · 10⁻³ MPa\n3 MPa do 4 MPa CMC 2 · 10⁻³ MPa\n4 MPa do 6 MPa CMC 4 · 10⁻³ MPa\n6 MPa do 10 MPa CMC 5 · 10⁻³ MPa\n10 MPa do 27 MPa CMC 1 · 10⁻² MPa\n28 MPa do 60 MPa CMC 2 · 10⁻² MPa\n60 MPa do 100 MPa CMC 6 · 10⁻² MPa\n100 MPa do 200 MPa CMC 1 · 10⁻¹ MPa\n210 MPa do 250 MPa CMC 3 · 10⁻¹ MPa\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW1/08 Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\n- cisnienie wzgledne (ciecz) Wzorcowanie — Cisnienie\nZakres:\n0,02 MPa do 0,4 MPa CMC 1 · 10⁻⁴ MPa\n0,4 MPa do 1 MPa CMC 4 · 10⁻⁴ MPa\n1 MPa do 3 MPa CMC 1 · 10⁻³ MPa\n3 MPa do 4 MPa CMC 2 · 10⁻³ MPa\n4 MPa do 6 MPa CMC 4 · 10⁻³ MPa\n6 MPa do 10 MPa CMC 5 · 10⁻³ MPa\n10 MPa do 27 MPa CMC 1 · 10⁻² MPa\n28 MPa do 60 MPa CMC 2 · 10⁻² MPa\n60 MPa do 100 MPa CMC 6 · 10⁻² MPa\n100 MPa do 200 MPa CMC 1 · 10⁻¹ MPa\n210 MPa do 250 MPa CMC 3 · 10⁻¹ MPa\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW1/08","search_en":"Bourdon tube pressure gauges Electronic pressure gauges - gauge pressure (liquid) Calibration — Pressure Internal procedure; At permanent location (S) Pressure Internal procedure At permanent location (S) IW/LW1/08","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":20,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"0,02 MPa to 0,4 MPa","cmc":"1 · 10⁻⁴ MPa"},{"name":"","range":"0,4 MPa to 1 MPa","cmc":"4 · 10⁻⁴ MPa"},{"name":"","range":"1 MPa to 3 MPa","cmc":"1 · 10⁻³ MPa"},{"name":"","range":"3 MPa to 4 MPa","cmc":"2 · 10⁻³ MPa"},{"name":"","range":"4 MPa to 6 MPa","cmc":"4 · 10⁻³ MPa"},{"name":"","range":"6 MPa to 10 MPa","cmc":"5 · 10⁻³ MPa"},{"name":"","range":"10 MPa to 27 MPa","cmc":"1 · 10⁻² MPa"},{"name":"","range":"28 MPa to 60 MPa","cmc":"2 · 10⁻² MPa"},{"name":"","range":"60 MPa to 100 MPa","cmc":"6 · 10⁻² MPa"},{"name":"","range":"100 MPa to 200 MPa","cmc":"1 · 10⁻¹ MPa"},{"name":"","range":"210 MPa to 250 MPa","cmc":"3 · 10⁻¹ MPa"}],"regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte - Überdruck (Flüssigkeit) Kalibrierung — Druck Internes Verfahren; Am festen Standort (S) Druck Internes Verfahren Am festen Standort (S) IW/LW1/08","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\n- Überdruck (Flüssigkeit)","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"0,02 MPa to 0,4 MPa","cmc":"1 · 10⁻⁴ MPa"},{"name":"","range":"0,4 MPa to 1 MPa","cmc":"4 · 10⁻⁴ MPa"},{"name":"","range":"1 MPa to 3 MPa","cmc":"1 · 10⁻³ MPa"},{"name":"","range":"3 MPa to 4 MPa","cmc":"2 · 10⁻³ MPa"},{"name":"","range":"4 MPa to 6 MPa","cmc":"4 · 10⁻³ MPa"},{"name":"","range":"6 MPa to 10 MPa","cmc":"5 · 10⁻³ MPa"},{"name":"","range":"10 MPa to 27 MPa","cmc":"1 · 10⁻² MPa"},{"name":"","range":"28 MPa to 60 MPa","cmc":"2 · 10⁻² MPa"},{"name":"","range":"60 MPa to 100 MPa","cmc":"6 · 10⁻² MPa"},{"name":"","range":"100 MPa to 200 MPa","cmc":"1 · 10⁻¹ MPa"},{"name":"","range":"210 MPa to 250 MPa","cmc":"3 · 10⁻¹ MPa"}],"regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 - 表压（液体） 校准 — 压力 内部程序；在固定地点 (S) 压力 内部程序 在固定地点 (S) IW/LW1/08","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"弹簧管压力表\n电子压力计\n- 表压（液体）","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"0,02 MPa to 0,4 MPa","cmc":"1 · 10⁻⁴ MPa"},{"name":"","range":"0,4 MPa to 1 MPa","cmc":"4 · 10⁻⁴ MPa"},{"name":"","range":"1 MPa to 3 MPa","cmc":"1 · 10⁻³ MPa"},{"name":"","range":"3 MPa to 4 MPa","cmc":"2 · 10⁻³ MPa"},{"name":"","range":"4 MPa to 6 MPa","cmc":"4 · 10⁻³ MPa"},{"name":"","range":"6 MPa to 10 MPa","cmc":"5 · 10⁻³ MPa"},{"name":"","range":"10 MPa to 27 MPa","cmc":"1 · 10⁻² MPa"},{"name":"","range":"28 MPa to 60 MPa","cmc":"2 · 10⁻² MPa"},{"name":"","range":"60 MPa to 100 MPa","cmc":"6 · 10⁻² MPa"},{"name":"","range":"100 MPa to 200 MPa","cmc":"1 · 10⁻¹ MPa"},{"name":"","range":"210 MPa to 250 MPa","cmc":"3 · 10⁻¹ MPa"}],"regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry - přetlak (kapalina) Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) Tlak Vnitřní postup Ve stálé lokalitě (S) IW/LW1/08","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\n- přetlak (kapalina)"},{"_id":"54d8371e533b6bdd9cfff017","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (with temperature recording)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do -26 °C","cmc":"0,030 °C"},{"name":"","range":"-25 °C do -11 °C","cmc":"0,060 °C"},{"name":"","range":"-10 °C do 99 °C","cmc":"0,050 °C"},{"name":"","range":"100 °C do 199 °C","cmc":"0,060 °C"},{"name":"","range":"200 °C do 250 °C","cmc":"0,080 °C"},{"name":"","range":"0 °C","cmc":"0,020 °C"}],"parameters_en":[{"name":"","range":"-80 °C to -26 °C","cmc":"0,030 °C"},{"name":"","range":"-25 °C to -11 °C","cmc":"0,060 °C"},{"name":"","range":"-10 °C to 99 °C","cmc":"0,050 °C"},{"name":"","range":"100 °C to 199 °C","cmc":"0,060 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"0,080 °C"},{"name":"","range":"0 °C","cmc":"0,020 °C"}],"technique":"Procedura wewnętrzna; Metoda porównawcza\nWzorcowanie w termostatach cieczowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparison method\nCalibration in liquid baths; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza\nWzorcowanie w termostatach cieczowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparison method\nCalibration in liquid baths","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -26 °C CMC 0,030 °C\n-25 °C do -11 °C CMC 0,060 °C\n-10 °C do 99 °C CMC 0,050 °C\n100 °C do 199 °C CMC 0,060 °C\n200 °C do 250 °C CMC 0,080 °C\n0 °C CMC 0,020 °C\nProcedura wewnętrzna; Metoda porównawcza\nWzorcowanie w termostatach cieczowych; W stałej lokalizacji (S)","reference":"IW/LW1/07","norm_bases":["IW/LW1/07"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -26 °C CMC 0,030 °C\n-25 °C do -11 °C CMC 0,060 °C\n-10 °C do 99 °C CMC 0,050 °C\n100 °C do 199 °C CMC 0,060 °C\n200 °C do 250 °C CMC 0,080 °C\n0 °C CMC 0,020 °C\nProcedura wewnętrzna; Metoda porównawcza\nWzorcowanie w termostatach cieczowych; W stałej lokalizacji (S) IW/LW1/07 Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -26 °C CMC 0,030 °C\n-25 °C do -11 °C CMC 0,060 °C\n-10 °C do 99 °C CMC 0,050 °C\n100 °C do 199 °C CMC 0,060 °C\n200 °C do 250 °C CMC 0,080 °C\n0 °C CMC 0,020 °C\nProcedura wewnetrzna; Metoda porownawcza\nWzorcowanie w termostatach cieczowych; W stalej lokalizacji (S) IW/LW1/07","search_en":"Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Calibration — Temperature (electrical thermometry) Internal procedure; Comparison method Calibration in liquid baths; At permanent location (S) Temperature (electrical thermometry) Internal procedure Comparison method Calibration in liquid baths At permanent location (S) IW/LW1/07","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":21,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to -26 °C","cmc":"0,030 °C"},{"name":"","range":"-25 °C to -11 °C","cmc":"0,060 °C"},{"name":"","range":"-10 °C to 99 °C","cmc":"0,050 °C"},{"name":"","range":"100 °C to 199 °C","cmc":"0,060 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"0,080 °C"},{"name":"","range":"0 °C","cmc":"0,020 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Vergleichsverfahren Kalibrierung in Flüssigkeitsthermostaten; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Vergleichsverfahren Kalibrierung in Flüssigkeitsthermostaten Am festen Standort (S) IW/LW1/07","technique_de":"Interne Verfahrensanweisung; Vergleichsverfahren\nKalibrierung in Flüssigkeitsthermostaten; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren\nKalibrierung in Flüssigkeitsthermostaten","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C to -26 °C","cmc":"0,030 °C"},{"name":"","range":"-25 °C to -11 °C","cmc":"0,060 °C"},{"name":"","range":"-10 °C to 99 °C","cmc":"0,050 °C"},{"name":"","range":"100 °C to 199 °C","cmc":"0,060 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"0,080 °C"},{"name":"","range":"0 °C","cmc":"0,020 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序；比较法 在液体恒温槽中校准; 在固定地点 (S) 温度（电测温） 内部程序 比较法 在液体恒温槽中校准 在固定地点 (S) IW/LW1/07","technique_zh":"内部程序；比较法\n在液体恒温槽中校准; 在固定地点 (S)","techniques_zh":["内部程序","比较法\n在液体恒温槽中校准","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to -26 °C","cmc":"0,030 °C"},{"name":"","range":"-25 °C to -11 °C","cmc":"0,060 °C"},{"name":"","range":"-10 °C to 99 °C","cmc":"0,050 °C"},{"name":"","range":"100 °C to 199 °C","cmc":"0,060 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"0,080 °C"},{"name":"","range":"0 °C","cmc":"0,020 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Srovnávací metoda Kalibrace v kapalinových termostatech; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Srovnávací metoda Kalibrace v kapalinových termostatech Ve stálé lokalitě (S) IW/LW1/07","technique_cs":"Vnitřní postup; Srovnávací metoda\nKalibrace v kapalinových termostatech; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda\nKalibrace v kapalinových termostatech","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"},{"_id":"ccaa94ee55ba2d81f2c05f27","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (with temperature recording)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-30 °C do 0 °C","cmc":"0,5 °C"},{"name":"","range":"1 °C do 40 °C","cmc":"0,2 °C"},{"name":"","range":"41 °C do 80 °C","cmc":"0,3 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 0 °C","cmc":"0,5 °C"},{"name":"","range":"1 °C to 40 °C","cmc":"0,2 °C"},{"name":"","range":"41 °C to 80 °C","cmc":"0,3 °C"}],"technique":"Procedura wewnętrzna; Metoda porównawcza\nWzorcowanie w komorze klimatycznej; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparison method\nCalibration in a climatic chamber; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza\nWzorcowanie w komorze klimatycznej","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparison method\nCalibration in a climatic chamber","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 0 °C CMC 0,5 °C\n1 °C do 40 °C CMC 0,2 °C\n41 °C do 80 °C CMC 0,3 °C\nProcedura wewnętrzna; Metoda porównawcza\nWzorcowanie w komorze klimatycznej; W stałej lokalizacji (S)","reference":"IW/LW1/15","norm_bases":["IW/LW1/15"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 0 °C CMC 0,5 °C\n1 °C do 40 °C CMC 0,2 °C\n41 °C do 80 °C CMC 0,3 °C\nProcedura wewnętrzna; Metoda porównawcza\nWzorcowanie w komorze klimatycznej; W stałej lokalizacji (S) IW/LW1/15 Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 0 °C CMC 0,5 °C\n1 °C do 40 °C CMC 0,2 °C\n41 °C do 80 °C CMC 0,3 °C\nProcedura wewnetrzna; Metoda porownawcza\nWzorcowanie w komorze klimatycznej; W stalej lokalizacji (S) IW/LW1/15","search_en":"Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Calibration — Temperature (electrical thermometry) Internal procedure; Comparison method Calibration in a climatic chamber; At permanent location (S) Temperature (electrical thermometry) Internal procedure Comparison method Calibration in a climatic chamber At permanent location (S) IW/LW1/15","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":22,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-30 °C to 0 °C","cmc":"0,5 °C"},{"name":"","range":"1 °C to 40 °C","cmc":"0,2 °C"},{"name":"","range":"41 °C to 80 °C","cmc":"0,3 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Vergleichsverfahren Kalibrierung in einer Klimakammer; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Vergleichsverfahren Kalibrierung in der Klimakammer Am festen Standort (S) IW/LW1/15","technique_de":"Interne Verfahrensanweisung; Vergleichsverfahren\nKalibrierung in einer Klimakammer; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren\nKalibrierung in der Klimakammer","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-30 °C to 0 °C","cmc":"0,5 °C"},{"name":"","range":"1 °C to 40 °C","cmc":"0,2 °C"},{"name":"","range":"41 °C to 80 °C","cmc":"0,3 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序；比较法 在气候箱中校准；在固定地点 (S) 温度（电测温） 内部程序 比较法 在气候箱中校准 在固定地点 (S) IW/LW1/15","technique_zh":"内部程序；比较法\n在气候箱中校准；在固定地点 (S)","techniques_zh":["内部程序","比较法\n在气候箱中校准","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-30 °C to 0 °C","cmc":"0,5 °C"},{"name":"","range":"1 °C to 40 °C","cmc":"0,2 °C"},{"name":"","range":"41 °C to 80 °C","cmc":"0,3 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Srovnávací metoda Kalibrace v klimatické komoře; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Srovnávací metoda Kalibrace v klimatické komoře Ve stálé lokalitě (S) IW/LW1/15","technique_cs":"Vnitřní postup; Srovnávací metoda\nKalibrace v klimatické komoře; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda\nKalibrace v klimatické komoře","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"},{"_id":"bc1f1dea3a7adc60ab72959a","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Termometry szklane cieczowe","test_object_en":"Liquid-in-glass thermometers","methodology":"Wzorcowanie — Temperatura (termometria nieelektryczna)","methodology_en":"Calibration — Temperature (non-electrical thermometry)","parameters":[{"name":"","range":"-50 °C do -26 °C","cmc":"0,03 °C"},{"name":"","range":"-25 °C do -11 °C","cmc":"0,05 °C"},{"name":"","range":"-10 °C do 100 °C","cmc":"0,04 °C"},{"name":"","range":"101 °C do 199 °C","cmc":"0,06 °C"},{"name":"","range":"200 °C do 250 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,02 °C"}],"parameters_en":[{"name":"","range":"-50 °C to -26 °C","cmc":"0,03 °C"},{"name":"","range":"-25 °C to -11 °C","cmc":"0,05 °C"},{"name":"","range":"-10 °C to 100 °C","cmc":"0,04 °C"},{"name":"","range":"101 °C to 199 °C","cmc":"0,06 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,02 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-50 °C do -26 °C CMC 0,03 °C\n-25 °C do -11 °C CMC 0,05 °C\n-10 °C do 100 °C CMC 0,04 °C\n101 °C do 199 °C CMC 0,06 °C\n200 °C do 250 °C CMC 0,08 °C\n0 °C CMC 0,02 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW1/06 w oparciu o OIML R 133:2002","norm_bases":["IW/LW1/06","OIML R 133:2002"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria nieelektryczna)","regulatory_area_en":"Temperature (non-electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Termometry szklane cieczowe Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-50 °C do -26 °C CMC 0,03 °C\n-25 °C do -11 °C CMC 0,05 °C\n-10 °C do 100 °C CMC 0,04 °C\n101 °C do 199 °C CMC 0,06 °C\n200 °C do 250 °C CMC 0,08 °C\n0 °C CMC 0,02 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW1/06 w oparciu o OIML R 133:2002 Termometry szklane cieczowe Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-50 °C do -26 °C CMC 0,03 °C\n-25 °C do -11 °C CMC 0,05 °C\n-10 °C do 100 °C CMC 0,04 °C\n101 °C do 199 °C CMC 0,06 °C\n200 °C do 250 °C CMC 0,08 °C\n0 °C CMC 0,02 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW1/06 w oparciu o OIML R 133:2002","search_en":"Liquid-in-glass thermometers Calibration — Temperature (non-electrical thermometry) Internal procedure; At permanent location (S) Temperature (non-electrical thermometry) Internal procedure At permanent location (S) IW/LW1/06 based on OIML R 133:2002","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":23,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"IW/LW1/06 based on OIML R 133:2002","methodology_de":"Kalibrierung — Temperatur (nichtelektrische Thermometrie)","parameters_de":[{"name":"","range":"-50 °C to -26 °C","cmc":"0,03 °C"},{"name":"","range":"-25 °C to -11 °C","cmc":"0,05 °C"},{"name":"","range":"-10 °C to 100 °C","cmc":"0,04 °C"},{"name":"","range":"101 °C to 199 °C","cmc":"0,06 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,02 °C"}],"reference_de":"IW/LW1/06 auf Grundlage von OIML R 133:2002","regulatory_area_de":"Temperatur (nichtelektrische Thermometrie)","search_de":"Flüssigkeits-Glasthermometer Kalibrierung — Temperatur (nichtelektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (nichtelektrische Thermometrie) Internes Verfahren Am festen Standort (S) IW/LW1/06 auf Grundlage von OIML R 133:2002","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Flüssigkeits-Glasthermometer","methodology_zh":"校准 — 温度（非电测温）","parameters_zh":[{"name":"","range":"-50 °C to -26 °C","cmc":"0,03 °C"},{"name":"","range":"-25 °C to -11 °C","cmc":"0,05 °C"},{"name":"","range":"-10 °C to 100 °C","cmc":"0,04 °C"},{"name":"","range":"101 °C to 199 °C","cmc":"0,06 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,02 °C"}],"reference_zh":"IW/LW1/06 依据OIML R 133:2002","regulatory_area_zh":"温度（非电测温）","search_zh":"玻璃液体温度计 校准 — 温度（非电测温） 内部程序；在固定地点 (S) 温度（非电测温） 内部程序 在固定地点 (S) IW/LW1/06 依据OIML R 133:2002","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"玻璃液体温度计","methodology_cs":"Kalibrace — Teplota (neelektrická termometrie)","parameters_cs":[{"name":"","range":"-50 °C to -26 °C","cmc":"0,03 °C"},{"name":"","range":"-25 °C to -11 °C","cmc":"0,05 °C"},{"name":"","range":"-10 °C to 100 °C","cmc":"0,04 °C"},{"name":"","range":"101 °C to 199 °C","cmc":"0,06 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"0,08 °C"},{"name":"","range":"0 °C","cmc":"0,02 °C"}],"reference_cs":"IW/LW1/06 na základě OIML R 133:2002","regulatory_area_cs":"Teplota (neelektrická termometrie)","search_cs":"Skleněné kapalinové teploměry Kalibrace — Teplota (neelektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (neelektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) IW/LW1/06 na základě OIML R 133:2002","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Skleněné kapalinové teploměry"},{"_id":"6f7ebd5024f3dacca4882c4e","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Pirometry radiacyjne","test_object_en":"Radiation pyrometers","methodology":"Wzorcowanie — Temperatura (termometria radiacyjna)","methodology_en":"Calibration — Temperature (radiation thermometry)","parameters":[{"name":"","range":"-15 °C do -1 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C do 50 °C","cmc":"1,1 °C"},{"name":"","range":"51 °C do 100 °C","cmc":"1,4 °C"},{"name":"","range":"101 °C do 163 °C","cmc":"2,3 °C"},{"name":"","range":"164 °C do 300 °C","cmc":"2,4 °C"},{"name":"","range":"301 °C do 500 °C","cmc":"3,0 °C"}],"parameters_en":[{"name":"","range":"-15 °C to -1 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C to 50 °C","cmc":"1,1 °C"},{"name":"","range":"51 °C to 100 °C","cmc":"1,4 °C"},{"name":"","range":"101 °C to 163 °C","cmc":"2,3 °C"},{"name":"","range":"164 °C to 300 °C","cmc":"2,4 °C"},{"name":"","range":"301 °C to 500 °C","cmc":"3,0 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-15 °C do -1 °C CMC 1,6 °C\n0 °C do 50 °C CMC 1,1 °C\n51 °C do 100 °C CMC 1,4 °C\n101 °C do 163 °C CMC 2,3 °C\n164 °C do 300 °C CMC 2,4 °C\n301 °C do 500 °C CMC 3,0 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW1/13","norm_bases":["IW/LW1/13"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria radiacyjna)","regulatory_area_en":"Temperature (radiation thermometry)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Długości i Termometrii, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Length and Thermometry Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Pirometry radiacyjne Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-15 °C do -1 °C CMC 1,6 °C\n0 °C do 50 °C CMC 1,1 °C\n51 °C do 100 °C CMC 1,4 °C\n101 °C do 163 °C CMC 2,3 °C\n164 °C do 300 °C CMC 2,4 °C\n301 °C do 500 °C CMC 3,0 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW1/13 Pirometry radiacyjne Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-15 °C do -1 °C CMC 1,6 °C\n0 °C do 50 °C CMC 1,1 °C\n51 °C do 100 °C CMC 1,4 °C\n101 °C do 163 °C CMC 2,3 °C\n164 °C do 300 °C CMC 2,4 °C\n301 °C do 500 °C CMC 3,0 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW1/13","search_en":"Radiation pyrometers Calibration — Temperature (radiation thermometry) Internal procedure; At permanent location (S) Temperature (radiation thermometry) Internal procedure At permanent location (S) IW/LW1/13","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":24,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (Strahlungsthermometrie)","parameters_de":[{"name":"","range":"-15 °C to -1 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C to 50 °C","cmc":"1,1 °C"},{"name":"","range":"51 °C to 100 °C","cmc":"1,4 °C"},{"name":"","range":"101 °C to 163 °C","cmc":"2,3 °C"},{"name":"","range":"164 °C to 300 °C","cmc":"2,4 °C"},{"name":"","range":"301 °C to 500 °C","cmc":"3,0 °C"}],"regulatory_area_de":"Temperatur (Strahlungsthermometrie)","search_de":"Strahlungspyrometer Kalibrierung — Temperatur (Strahlungsthermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (Strahlungsthermometrie) Internes Verfahren Am festen Standort (S) IW/LW1/13","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Strahlungspyrometer","methodology_zh":"校准 — 温度（辐射测温）","parameters_zh":[{"name":"","range":"-15 °C to -1 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C to 50 °C","cmc":"1,1 °C"},{"name":"","range":"51 °C to 100 °C","cmc":"1,4 °C"},{"name":"","range":"101 °C to 163 °C","cmc":"2,3 °C"},{"name":"","range":"164 °C to 300 °C","cmc":"2,4 °C"},{"name":"","range":"301 °C to 500 °C","cmc":"3,0 °C"}],"regulatory_area_zh":"温度（辐射测温）","search_zh":"辐射高温计 校准 — 温度（辐射测温） 内部程序；在固定地点 (S) 温度（辐射测温） 内部程序 在固定地点 (S) IW/LW1/13","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"辐射高温计","methodology_cs":"Kalibrace — Teplota (radiační termometrie)","parameters_cs":[{"name":"","range":"-15 °C to -1 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C to 50 °C","cmc":"1,1 °C"},{"name":"","range":"51 °C to 100 °C","cmc":"1,4 °C"},{"name":"","range":"101 °C to 163 °C","cmc":"2,3 °C"},{"name":"","range":"164 °C to 300 °C","cmc":"2,4 °C"},{"name":"","range":"301 °C to 500 °C","cmc":"3,0 °C"}],"regulatory_area_cs":"Teplota (radiační termometrie)","search_cs":"Radiační pyrometry Kalibrace — Teplota (radiační termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (radiační termometrie) Vnitřní postup Ve stálé lokalitě (S) IW/LW1/13","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Radiační pyrometry"},{"_id":"8153af390dad1e1d045eb3d4","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Wagi nieautomatyczne elektroniczne","test_object_en":"Non-automatic electronic weighing instruments","methodology":"Wzorcowanie — Masa (wagi)","methodology_en":"Calibration — Mass (weighing instruments)","parameters":[{"name":"","range":"do 1 kg","cmc":"5 · 10⁻⁵ %"},{"name":"","range":"1 kg do 10 kg","cmc":"1,7 · 10⁻⁴ %"},{"name":"","range":"10 kg do 50 kg","cmc":"8 · 10⁻⁴ %"},{"name":"","range":"50 kg do 500 kg","cmc":"1,3 · 10⁻³ %"}],"parameters_en":[{"name":"","range":"do 1 kg","cmc":"5 · 10⁻⁵ %"},{"name":"","range":"1 kg to 10 kg","cmc":"1,7 · 10⁻⁴ %"},{"name":"","range":"10 kg do 50 kg","cmc":"8 · 10⁻⁴ %"},{"name":"","range":"50 kg do 500 kg","cmc":"1,3 · 10⁻³ %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (wagi)\nZakres:\ndo 1 kg CMC 5 · 10⁻⁵ %\n1 kg do 10 kg CMC 1,7 · 10⁻⁴ %\n10 kg do 50 kg CMC 8 · 10⁻⁴ %\n50 kg do 500 kg CMC 1,3 · 10⁻³ %\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"IW/LW2/01 w oparciu o EURAMET cg-18 v. 4.0","norm_bases":["IW/LW2/01","EURAMET cg-18 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (wagi)","regulatory_area_en":"Mass (weighing instruments)","outside_premises":true,"location_of_activity":"S, P","note":"Laboratorium Masy, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Mass Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Wagi nieautomatyczne elektroniczne Wzorcowanie — Masa (wagi)\nZakres:\ndo 1 kg CMC 5 · 10⁻⁵ %\n1 kg do 10 kg CMC 1,7 · 10⁻⁴ %\n10 kg do 50 kg CMC 8 · 10⁻⁴ %\n50 kg do 500 kg CMC 1,3 · 10⁻³ %\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) IW/LW2/01 w oparciu o EURAMET cg-18 v. 4.0 Wagi nieautomatyczne elektroniczne Wzorcowanie — Masa (wagi)\nZakres:\ndo 1 kg CMC 5 · 10⁻⁵ %\n1 kg do 10 kg CMC 1,7 · 10⁻⁴ %\n10 kg do 50 kg CMC 8 · 10⁻⁴ %\n50 kg do 500 kg CMC 1,3 · 10⁻³ %\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) IW/LW2/01 w oparciu o EURAMET cg-18 v. 4.0","search_en":"Non-automatic electronic weighing instruments Calibration — Mass (weighing instruments) Internal procedure; At permanent location (S) and outside of it (P) Mass (weighing instruments) Internal procedure At permanent location (S) and outside of it (P) IW/LW2/01 based on EURAMET cg-18 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":25,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"IW/LW2/01 based on EURAMET cg-18 v. 4.0","methodology_de":"Kalibrierung — Masse (Waagen)","parameters_de":[{"name":"","range":"do 1 kg","cmc":"5 · 10⁻⁵ %"},{"name":"","range":"1 kg bis 10 kg","cmc":"1,7 · 10⁻⁴ %"},{"name":"","range":"10 kg do 50 kg","cmc":"8 · 10⁻⁴ %"},{"name":"","range":"50 kg do 500 kg","cmc":"1,3 · 10⁻³ %"}],"reference_de":"IW/LW2/01 auf Grundlage von EURAMET cg-18 v. 4.0","regulatory_area_de":"Masse (Waagen)","search_de":"Nichtselbsttätige elektronische Waagen Kalibrierung — Masse (Waagen) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Masse (Waagen) Internes Verfahren Am festen Standort (S) und außerhalb (P) IW/LW2/01 auf Grundlage von EURAMET cg-18 v. 4.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Nichtselbsttätige elektronische Waagen","methodology_zh":"校准 — 质量（衡器）","parameters_zh":[{"name":"","range":"do 1 kg","cmc":"5 · 10⁻⁵ %"},{"name":"","range":"1 kg 至 10 kg","cmc":"1,7 · 10⁻⁴ %"},{"name":"","range":"10 kg do 50 kg","cmc":"8 · 10⁻⁴ %"},{"name":"","range":"50 kg do 500 kg","cmc":"1,3 · 10⁻³ %"}],"reference_zh":"IW/LW2/01 依据EURAMET cg-18 v. 4.0","regulatory_area_zh":"质量（衡器）","search_zh":"非自动电子衡器 校准 — 质量（衡器） 内部程序；在固定地点 (S) 及固定地点以外 (P) 质量（衡器） 内部程序 在固定地点 (S) 及固定地点以外 (P) IW/LW2/01 依据EURAMET cg-18 v. 4.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"非自动电子衡器","methodology_cs":"Kalibrace — Hmotnost (váhy)","parameters_cs":[{"name":"","range":"do 1 kg","cmc":"5 · 10⁻⁵ %"},{"name":"","range":"1 kg do 10 kg","cmc":"1,7 · 10⁻⁴ %"},{"name":"","range":"10 kg do 50 kg","cmc":"8 · 10⁻⁴ %"},{"name":"","range":"50 kg do 500 kg","cmc":"1,3 · 10⁻³ %"}],"reference_cs":"IW/LW2/01 na základě EURAMET cg-18 v. 4.0","regulatory_area_cs":"Hmotnost (váhy)","search_cs":"Elektronické váhy s neautomatickou činností Kalibrace — Hmotnost (váhy) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Hmotnost (váhy) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) IW/LW2/01 na základě EURAMET cg-18 v. 4.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Elektronické váhy s neautomatickou činností"},{"_id":"a64a9efc35510bded059fe52","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Obciążniki","test_object_en":"Load weights","methodology":"Wzorcowanie — Masa (odważniki i wzorce masy)","methodology_en":"Calibration — Mass (weights and mass standards)","parameters":[{"name":"","range":"1 g do 5 g","cmc":"0,04 mg"},{"name":"","range":"10 g do 100 g","cmc":"0,12 mg"},{"name":"","range":"200 g","cmc":"0,45 mg"},{"name":"","range":"500 g","cmc":"1,00 mg"},{"name":"","range":"1 kg","cmc":"1,73 mg"},{"name":"","range":"2 kg","cmc":"3,29 mg"},{"name":"","range":"5 kg","cmc":"8,40 mg"}],"parameters_en":[{"name":"","range":"1 g to 5 g","cmc":"0,04 mg"},{"name":"","range":"10 g to 100 g","cmc":"0,12 mg"},{"name":"","range":"200 g","cmc":"0,45 mg"},{"name":"","range":"500 g","cmc":"1,00 mg"},{"name":"","range":"1 kg","cmc":"1,73 mg"},{"name":"","range":"2 kg","cmc":"3,29 mg"},{"name":"","range":"5 kg","cmc":"8,40 mg"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (odważniki i wzorce masy)\nZakres:\n1 g do 5 g CMC 0,04 mg\n10 g do 100 g CMC 0,12 mg\n200 g CMC 0,45 mg\n500 g CMC 1,00 mg\n1 kg CMC 1,73 mg\n2 kg CMC 3,29 mg\n5 kg CMC 8,40 mg\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW2/02 w oparciu o OIML R 111-1:2004 Załącznik C","norm_bases":["IW/LW2/02","OIML R 111-1:2004 Załącznik C"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (odważniki i wzorce masy)","regulatory_area_en":"Mass (weights and mass standards)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Masy, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Mass Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Obciążniki Wzorcowanie — Masa (odważniki i wzorce masy)\nZakres:\n1 g do 5 g CMC 0,04 mg\n10 g do 100 g CMC 0,12 mg\n200 g CMC 0,45 mg\n500 g CMC 1,00 mg\n1 kg CMC 1,73 mg\n2 kg CMC 3,29 mg\n5 kg CMC 8,40 mg\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW2/02 w oparciu o OIML R 111-1:2004 Załącznik C Obciazniki Wzorcowanie — Masa (odwazniki i wzorce masy)\nZakres:\n1 g do 5 g CMC 0,04 mg\n10 g do 100 g CMC 0,12 mg\n200 g CMC 0,45 mg\n500 g CMC 1,00 mg\n1 kg CMC 1,73 mg\n2 kg CMC 3,29 mg\n5 kg CMC 8,40 mg\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW2/02 w oparciu o OIML R 111-1:2004 Zalacznik C","search_en":"Load weights Calibration — Mass (weights and mass standards) Internal procedure; At permanent location (S) Mass (weights and mass standards) Internal procedure At permanent location (S) IW/LW2/02 based on OIML R 111-1:2004 Annex C","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":26,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"IW/LW2/02 based on OIML R 111-1:2004 Annex C","methodology_de":"Kalibrierung — Masse (Gewichtstücke und Massenormale)","parameters_de":[{"name":"","range":"1 g to 5 g","cmc":"0,04 mg"},{"name":"","range":"10 g to 100 g","cmc":"0,12 mg"},{"name":"","range":"200 g","cmc":"0,45 mg"},{"name":"","range":"500 g","cmc":"1,00 mg"},{"name":"","range":"1 kg","cmc":"1,73 mg"},{"name":"","range":"2 kg","cmc":"3,29 mg"},{"name":"","range":"5 kg","cmc":"8,40 mg"}],"reference_de":"IW/LW2/02 auf Grundlage von OIML R 111-1:2004 Anhang C","regulatory_area_de":"Masse (Gewichtstücke und Massenormale)","search_de":"Belastungsgewichte Kalibrierung — Masse (Gewichtstücke und Massenormale) Internes Verfahren; Am festen Standort (S) Masse (Gewichtstücke und Massenormale) Internes Verfahren Am festen Standort (S) IW/LW2/02 auf Grundlage von OIML R 111-1:2004 Anhang C","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Belastungsgewichte","methodology_zh":"校准 — 质量（砝码和质量标准器）","parameters_zh":[{"name":"","range":"1 g to 5 g","cmc":"0,04 mg"},{"name":"","range":"10 g to 100 g","cmc":"0,12 mg"},{"name":"","range":"200 g","cmc":"0,45 mg"},{"name":"","range":"500 g","cmc":"1,00 mg"},{"name":"","range":"1 kg","cmc":"1,73 mg"},{"name":"","range":"2 kg","cmc":"3,29 mg"},{"name":"","range":"5 kg","cmc":"8,40 mg"}],"reference_zh":"IW/LW2/02 依据OIML R 111-1:2004附录C","regulatory_area_zh":"质量（砝码和质量标准器）","search_zh":"砝码 校准 — 质量（砝码和质量标准器） 内部程序；在固定地点 (S) 质量（砝码和质量标准器） 内部程序 在固定地点 (S) IW/LW2/02 依据OIML R 111-1:2004附录C","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"砝码","methodology_cs":"Kalibrace — Hmotnost (závaží a etalony hmotnosti)","parameters_cs":[{"name":"","range":"1 g to 5 g","cmc":"0,04 mg"},{"name":"","range":"10 g to 100 g","cmc":"0,12 mg"},{"name":"","range":"200 g","cmc":"0,45 mg"},{"name":"","range":"500 g","cmc":"1,00 mg"},{"name":"","range":"1 kg","cmc":"1,73 mg"},{"name":"","range":"2 kg","cmc":"3,29 mg"},{"name":"","range":"5 kg","cmc":"8,40 mg"}],"reference_cs":"IW/LW2/02 na základě OIML R 111-1:2004 Příloha C","regulatory_area_cs":"Hmotnost (závaží a etalony hmotnosti)","search_cs":"Zatěžovací závaží Kalibrace — Hmotnost (závaží a etalony hmotnosti) Vnitřní postup; Ve stálé lokalitě (S) Hmotnost (závaží a etalony hmotnosti) Vnitřní postup Ve stálé lokalitě (S) IW/LW2/02 na základě OIML R 111-1:2004 Příloha C","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Zatěžovací závaží"},{"_id":"dd19b8d814d4b3a41ee13f33","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Wzorce masy i odważniki klasy dokładności E2","test_object_en":"Mass standards and weights of accuracy class E2","methodology":"Wzorcowanie — Masa (odważniki i wzorce masy)","methodology_en":"Calibration — Mass (weights and mass standards)","parameters":[{"name":"","range":"1 mg","cmc":"0,0020 mg"},{"name":"","range":"2 mg","cmc":"0,0020 mg"},{"name":"","range":"5 mg","cmc":"0,0020 mg"},{"name":"","range":"10 mg","cmc":"0,0026 mg"},{"name":"","range":"20 mg","cmc":"0,003 mg"},{"name":"","range":"50 mg","cmc":"0,004 mg"},{"name":"","range":"100 mg","cmc":"0,005 mg"},{"name":"","range":"200 mg","cmc":"0,006 mg"},{"name":"","range":"500 mg","cmc":"0,008 mg"},{"name":"","range":"1g","cmc":"0,010 mg"},{"name":"","range":"2g","cmc":"0,012 mg"},{"name":"","range":"5g","cmc":"0,015 mg"},{"name":"","range":"10 g","cmc":"0,020 mg"},{"name":"","range":"20 g","cmc":"0,025 mg"},{"name":"","range":"50 g","cmc":"0,03 mg"},{"name":"","range":"100 g","cmc":"0,05 mg"},{"name":"","range":"200 g","cmc":"0,10 mg"},{"name":"","range":"500 g","cmc":"0,25 mg"},{"name":"","range":"1 kg","cmc":"0,50 mg"}],"parameters_en":[{"name":"","range":"1 mg","cmc":"0,0020 mg"},{"name":"","range":"2 mg","cmc":"0,0020 mg"},{"name":"","range":"5 mg","cmc":"0,0020 mg"},{"name":"","range":"10 mg","cmc":"0,0026 mg"},{"name":"","range":"20 mg","cmc":"0,003 mg"},{"name":"","range":"50 mg","cmc":"0,004 mg"},{"name":"","range":"100 mg","cmc":"0,005 mg"},{"name":"","range":"200 mg","cmc":"0,006 mg"},{"name":"","range":"500 mg","cmc":"0,008 mg"},{"name":"","range":"1g","cmc":"0,010 mg"},{"name":"","range":"2g","cmc":"0,012 mg"},{"name":"","range":"5g","cmc":"0,015 mg"},{"name":"","range":"10 g","cmc":"0,020 mg"},{"name":"","range":"20 g","cmc":"0,025 mg"},{"name":"","range":"50 g","cmc":"0,03 mg"},{"name":"","range":"100 g","cmc":"0,05 mg"},{"name":"","range":"200 g","cmc":"0,10 mg"},{"name":"","range":"500 g","cmc":"0,25 mg"},{"name":"","range":"1 kg","cmc":"0,50 mg"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (odważniki i wzorce masy)\nZakres:\n1 mg CMC 0,0020 mg\n2 mg CMC 0,0020 mg\n5 mg CMC 0,0020 mg\n10 mg CMC 0,0026 mg\n20 mg CMC 0,003 mg\n50 mg CMC 0,004 mg\n100 mg CMC 0,005 mg\n200 mg CMC 0,006 mg\n500 mg CMC 0,008 mg\n1g CMC 0,010 mg\n2g CMC 0,012 mg\n5g CMC 0,015 mg\n10 g CMC 0,020 mg\n20 g CMC 0,025 mg\n50 g CMC 0,03 mg\n100 g CMC 0,05 mg\n200 g CMC 0,10 mg\n500 g CMC 0,25 mg\n1 kg CMC 0,50 mg\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW2/02 w oparciu o OIML R 111-1:2004 Załącznik C","norm_bases":["IW/LW2/02","OIML R 111-1:2004 Załącznik C"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (odważniki i wzorce masy)","regulatory_area_en":"Mass (weights and mass standards)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Masy, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Mass Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Wzorce masy i odważniki klasy dokładności E2 Wzorcowanie — Masa (odważniki i wzorce masy)\nZakres:\n1 mg CMC 0,0020 mg\n2 mg CMC 0,0020 mg\n5 mg CMC 0,0020 mg\n10 mg CMC 0,0026 mg\n20 mg CMC 0,003 mg\n50 mg CMC 0,004 mg\n100 mg CMC 0,005 mg\n200 mg CMC 0,006 mg\n500 mg CMC 0,008 mg\n1g CMC 0,010 mg\n2g CMC 0,012 mg\n5g CMC 0,015 mg\n10 g CMC 0,020 mg\n20 g CMC 0,025 mg\n50 g CMC 0,03 mg\n100 g CMC 0,05 mg\n200 g CMC 0,10 mg\n500 g CMC 0,25 mg\n1 kg CMC 0,50 mg\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW2/02 w oparciu o OIML R 111-1:2004 Załącznik C Wzorce masy i odwazniki klasy dokladnosci E2 Wzorcowanie — Masa (odwazniki i wzorce masy)\nZakres:\n1 mg CMC 0,0020 mg\n2 mg CMC 0,0020 mg\n5 mg CMC 0,0020 mg\n10 mg CMC 0,0026 mg\n20 mg CMC 0,003 mg\n50 mg CMC 0,004 mg\n100 mg CMC 0,005 mg\n200 mg CMC 0,006 mg\n500 mg CMC 0,008 mg\n1g CMC 0,010 mg\n2g CMC 0,012 mg\n5g CMC 0,015 mg\n10 g CMC 0,020 mg\n20 g CMC 0,025 mg\n50 g CMC 0,03 mg\n100 g CMC 0,05 mg\n200 g CMC 0,10 mg\n500 g CMC 0,25 mg\n1 kg CMC 0,50 mg\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW2/02 w oparciu o OIML R 111-1:2004 Zalacznik C","search_en":"Mass standards and weights of accuracy class E2 Calibration — Mass (weights and mass standards) Internal procedure; At permanent location (S) Mass (weights and mass standards) Internal procedure At permanent location (S) IW/LW2/02 based on OIML R 111-1:2004 Annex C","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":27,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"IW/LW2/02 based on OIML R 111-1:2004 Annex C","methodology_de":"Kalibrierung — Masse (Gewichtstücke und Massenormale)","reference_de":"IW/LW2/02 auf Grundlage von OIML R 111-1:2004 Anhang C","regulatory_area_de":"Masse (Gewichtstücke und Massenormale)","search_de":"Massenormale und Gewichtstücke der Genauigkeitsklasse E2 Kalibrierung — Masse (Gewichtstücke und Massenormale) Internes Verfahren; Am festen Standort (S) Masse (Gewichtstücke und Massenormale) Internes Verfahren Am festen Standort (S) IW/LW2/02 auf Grundlage von OIML R 111-1:2004 Anhang C","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Massenormale und Gewichtstücke der Genauigkeitsklasse E2","methodology_zh":"校准 — 质量（砝码和质量标准器）","reference_zh":"IW/LW2/02 依据OIML R 111-1:2004附录C","regulatory_area_zh":"质量（砝码和质量标准器）","search_zh":"精度等级为E2的质量标准器和砝码 校准 — 质量（砝码和质量标准器） 内部程序；在固定地点 (S) 质量（砝码和质量标准器） 内部程序 在固定地点 (S) IW/LW2/02 依据OIML R 111-1:2004附录C","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"精度等级为E2的质量标准器和砝码","methodology_cs":"Kalibrace — Hmotnost (závaží a etalony hmotnosti)","reference_cs":"IW/LW2/02 na základě OIML R 111-1:2004 Příloha C","regulatory_area_cs":"Hmotnost (závaží a etalony hmotnosti)","search_cs":"Etalony hmotnosti a závaží třídy přesnosti E2 Kalibrace — Hmotnost (závaží a etalony hmotnosti) Vnitřní postup; Ve stálé lokalitě (S) Hmotnost (závaží a etalony hmotnosti) Vnitřní postup Ve stálé lokalitě (S) IW/LW2/02 na základě OIML R 111-1:2004 Příloha C","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Etalony hmotnosti a závaží třídy přesnosti E2"},{"_id":"f04fcb481423da7494bede53","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Wzorce masy i odważniki klasy dokładności F1","test_object_en":"Mass standards and weights of accuracy class F1","methodology":"Wzorcowanie — Masa (odważniki i wzorce masy)","methodology_en":"Calibration — Mass (weights and mass standards)","parameters":[{"name":"","range":"1 mg, 2 mg, 5 mg","cmc":"0,006 mg"},{"name":"","range":"10 mg","cmc":"0,008 mg"},{"name":"","range":"20 mg","cmc":"0,010 mg"},{"name":"","range":"50 mg","cmc":"0,013 mg"},{"name":"","range":"100 mg","cmc":"0,015 mg"},{"name":"","range":"200 mg","cmc":"0,020 mg"},{"name":"","range":"500 mg","cmc":"0,025 mg"},{"name":"","range":"1g","cmc":"0,03 mg"},{"name":"","range":"2g","cmc":"0,04 mg"},{"name":"","range":"5g","cmc":"0,05 mg"},{"name":"","range":"10 g","cmc":"0,06 mg"},{"name":"","range":"20 g","cmc":"0,08 mg"},{"name":"","range":"50 g","cmc":"0,10 mg"},{"name":"","range":"100 g","cmc":"0,15 mg"},{"name":"","range":"200 g","cmc":"0,3 mg"},{"name":"","range":"500 g","cmc":"0,8 mg"},{"name":"","range":"1 kg","cmc":"1,5 mg"},{"name":"","range":"2 kg","cmc":"3,0 mg"},{"name":"","range":"5 kg","cmc":"8 mg"},{"name":"","range":"10 kg","cmc":"15 mg"},{"name":"","range":"20 kg","cmc":"30 mg"}],"parameters_en":[{"name":"","range":"1 mg, 2 mg, 5 mg","cmc":"0,006 mg"},{"name":"","range":"10 mg","cmc":"0,008 mg"},{"name":"","range":"20 mg","cmc":"0,010 mg"},{"name":"","range":"50 mg","cmc":"0,013 mg"},{"name":"","range":"100 mg","cmc":"0,015 mg"},{"name":"","range":"200 mg","cmc":"0,020 mg"},{"name":"","range":"500 mg","cmc":"0,025 mg"},{"name":"","range":"1g","cmc":"0,03 mg"},{"name":"","range":"2g","cmc":"0,04 mg"},{"name":"","range":"5g","cmc":"0,05 mg"},{"name":"","range":"10 g","cmc":"0,06 mg"},{"name":"","range":"20 g","cmc":"0,08 mg"},{"name":"","range":"50 g","cmc":"0,10 mg"},{"name":"","range":"100 g","cmc":"0,15 mg"},{"name":"","range":"200 g","cmc":"0,3 mg"},{"name":"","range":"500 g","cmc":"0,8 mg"},{"name":"","range":"1 kg","cmc":"1,5 mg"},{"name":"","range":"2 kg","cmc":"3,0 mg"},{"name":"","range":"5 kg","cmc":"8 mg"},{"name":"","range":"10 kg","cmc":"15 mg"},{"name":"","range":"20 kg","cmc":"30 mg"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (odważniki i wzorce masy)\nZakres:\n1 mg, 2 mg, 5 mg CMC 0,006 mg\n10 mg CMC 0,008 mg\n20 mg CMC 0,010 mg\n50 mg CMC 0,013 mg\n100 mg CMC 0,015 mg\n200 mg CMC 0,020 mg\n500 mg CMC 0,025 mg\n1g CMC 0,03 mg\n2g CMC 0,04 mg\n5g CMC 0,05 mg\n10 g CMC 0,06 mg\n20 g CMC 0,08 mg\n50 g CMC 0,10 mg\n100 g CMC 0,15 mg\n200 g CMC 0,3 mg\n500 g CMC 0,8 mg\n1 kg CMC 1,5 mg\n2 kg CMC 3,0 mg\n5 kg CMC 8 mg\n10 kg CMC 15 mg\n20 kg CMC 30 mg\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW2/02 w oparciu o OIML R 111-1:2004 Załącznik C","norm_bases":["IW/LW2/02","OIML R 111-1:2004 Załącznik C"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (odważniki i wzorce masy)","regulatory_area_en":"Mass (weights and mass standards)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Masy, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Mass Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Wzorce masy i odważniki klasy dokładności F1 Wzorcowanie — Masa (odważniki i wzorce masy)\nZakres:\n1 mg, 2 mg, 5 mg CMC 0,006 mg\n10 mg CMC 0,008 mg\n20 mg CMC 0,010 mg\n50 mg CMC 0,013 mg\n100 mg CMC 0,015 mg\n200 mg CMC 0,020 mg\n500 mg CMC 0,025 mg\n1g CMC 0,03 mg\n2g CMC 0,04 mg\n5g CMC 0,05 mg\n10 g CMC 0,06 mg\n20 g CMC 0,08 mg\n50 g CMC 0,10 mg\n100 g CMC 0,15 mg\n200 g CMC 0,3 mg\n500 g CMC 0,8 mg\n1 kg CMC 1,5 mg\n2 kg CMC 3,0 mg\n5 kg CMC 8 mg\n10 kg CMC 15 mg\n20 kg CMC 30 mg\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW2/02 w oparciu o OIML R 111-1:2004 Załącznik C Wzorce masy i odwazniki klasy dokladnosci F1 Wzorcowanie — Masa (odwazniki i wzorce masy)\nZakres:\n1 mg, 2 mg, 5 mg CMC 0,006 mg\n10 mg CMC 0,008 mg\n20 mg CMC 0,010 mg\n50 mg CMC 0,013 mg\n100 mg CMC 0,015 mg\n200 mg CMC 0,020 mg\n500 mg CMC 0,025 mg\n1g CMC 0,03 mg\n2g CMC 0,04 mg\n5g CMC 0,05 mg\n10 g CMC 0,06 mg\n20 g CMC 0,08 mg\n50 g CMC 0,10 mg\n100 g CMC 0,15 mg\n200 g CMC 0,3 mg\n500 g CMC 0,8 mg\n1 kg CMC 1,5 mg\n2 kg CMC 3,0 mg\n5 kg CMC 8 mg\n10 kg CMC 15 mg\n20 kg CMC 30 mg\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW2/02 w oparciu o OIML R 111-1:2004 Zalacznik C","search_en":"Mass standards and weights of accuracy class F1 Calibration — Mass (weights and mass standards) Internal procedure; At permanent location (S) Mass (weights and mass standards) Internal procedure At permanent location (S) IW/LW2/02 based on OIML R 111-1:2004 Annex C","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":28,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"IW/LW2/02 based on OIML R 111-1:2004 Annex C","methodology_de":"Kalibrierung — Masse (Gewichtstücke und Massenormale)","reference_de":"IW/LW2/02 auf Grundlage von OIML R 111-1:2004 Anhang C","regulatory_area_de":"Masse (Gewichtstücke und Massenormale)","search_de":"Massenormale und Gewichtstücke der Genauigkeitsklasse F1 Kalibrierung — Masse (Gewichtstücke und Massenormale) Internes Verfahren; Am festen Standort (S) Masse (Gewichtstücke und Massenormale) Internes Verfahren Am festen Standort (S) IW/LW2/02 auf Grundlage von OIML R 111-1:2004 Anhang C","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Massenormale und Gewichtstücke der Genauigkeitsklasse F1","methodology_zh":"校准 — 质量（砝码和质量标准器）","reference_zh":"IW/LW2/02 依据OIML R 111-1:2004附录C","regulatory_area_zh":"质量（砝码和质量标准器）","search_zh":"精度等级为F1的质量标准器和砝码 校准 — 质量（砝码和质量标准器） 内部程序；在固定地点 (S) 质量（砝码和质量标准器） 内部程序 在固定地点 (S) IW/LW2/02 依据OIML R 111-1:2004附录C","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"精度等级为F1的质量标准器和砝码","methodology_cs":"Kalibrace — Hmotnost (závaží a etalony hmotnosti)","reference_cs":"IW/LW2/02 na základě OIML R 111-1:2004 Příloha C","regulatory_area_cs":"Hmotnost (závaží a etalony hmotnosti)","search_cs":"Etalony hmotnosti a závaží třídy přesnosti F1 Kalibrace — Hmotnost (závaží a etalony hmotnosti) Vnitřní postup; Ve stálé lokalitě (S) Hmotnost (závaží a etalony hmotnosti) Vnitřní postup Ve stálé lokalitě (S) IW/LW2/02 na základě OIML R 111-1:2004 Příloha C","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Etalony hmotnosti a závaží třídy přesnosti F1"},{"_id":"33a95782ce8c1a79cf80462d","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Wzorce masy i odważniki klasy dokładności F2","test_object_en":"Mass standards and weights of accuracy class F2","methodology":"Wzorcowanie — Masa (odważniki i wzorce masy)","methodology_en":"Calibration — Mass (weights and mass standards)","parameters":[{"name":"","range":"1 mg, 2 mg, 5 mg","cmc":"0,020 mg"},{"name":"","range":"10 mg","cmc":"0,025 mg"},{"name":"","range":"20 mg","cmc":"0,03 mg"},{"name":"","range":"50 mg","cmc":"0,04 mg"},{"name":"","range":"100 mg","cmc":"0,05 mg"},{"name":"","range":"200 mg","cmc":"0,06 mg"},{"name":"","range":"500 mg","cmc":"0,08 mg"},{"name":"","range":"1g","cmc":"0,10 mg"},{"name":"","range":"2g","cmc":"0,13 mg"},{"name":"","range":"5g","cmc":"0,15 mg"},{"name":"","range":"10 g","cmc":"0,2 mg"},{"name":"","range":"20 g","cmc":"0,25 mg"},{"name":"","range":"50 g","cmc":"0,3 mg"},{"name":"","range":"100 g","cmc":"0,5 mg"},{"name":"","range":"200 g","cmc":"1,0 mg"},{"name":"","range":"500 g","cmc":"2,5 mg"},{"name":"","range":"1 kg","cmc":"5 mg"},{"name":"","range":"2 kg","cmc":"10 mg"},{"name":"","range":"5 kg","cmc":"25 mg"},{"name":"","range":"10 kg","cmc":"50 mg"},{"name":"","range":"20 kg","cmc":"100 mg"}],"parameters_en":[{"name":"","range":"1 mg, 2 mg, 5 mg","cmc":"0,020 mg"},{"name":"","range":"10 mg","cmc":"0,025 mg"},{"name":"","range":"20 mg","cmc":"0,03 mg"},{"name":"","range":"50 mg","cmc":"0,04 mg"},{"name":"","range":"100 mg","cmc":"0,05 mg"},{"name":"","range":"200 mg","cmc":"0,06 mg"},{"name":"","range":"500 mg","cmc":"0,08 mg"},{"name":"","range":"1g","cmc":"0,10 mg"},{"name":"","range":"2g","cmc":"0,13 mg"},{"name":"","range":"5g","cmc":"0,15 mg"},{"name":"","range":"10 g","cmc":"0,2 mg"},{"name":"","range":"20 g","cmc":"0,25 mg"},{"name":"","range":"50 g","cmc":"0,3 mg"},{"name":"","range":"100 g","cmc":"0,5 mg"},{"name":"","range":"200 g","cmc":"1,0 mg"},{"name":"","range":"500 g","cmc":"2,5 mg"},{"name":"","range":"1 kg","cmc":"5 mg"},{"name":"","range":"2 kg","cmc":"10 mg"},{"name":"","range":"5 kg","cmc":"25 mg"},{"name":"","range":"10 kg","cmc":"50 mg"},{"name":"","range":"20 kg","cmc":"100 mg"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (odważniki i wzorce masy)\nZakres:\n1 mg, 2 mg, 5 mg CMC 0,020 mg\n10 mg CMC 0,025 mg\n20 mg CMC 0,03 mg\n50 mg CMC 0,04 mg\n100 mg CMC 0,05 mg\n200 mg CMC 0,06 mg\n500 mg CMC 0,08 mg\n1g CMC 0,10 mg\n2g CMC 0,13 mg\n5g CMC 0,15 mg\n10 g CMC 0,2 mg\n20 g CMC 0,25 mg\n50 g CMC 0,3 mg\n100 g CMC 0,5 mg\n200 g CMC 1,0 mg\n500 g CMC 2,5 mg\n1 kg CMC 5 mg\n2 kg CMC 10 mg\n5 kg CMC 25 mg\n10 kg CMC 50 mg\n20 kg CMC 100 mg\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW2/02 w oparciu o OIML R 111-1:2004 Załącznik C","norm_bases":["IW/LW2/02","OIML R 111-1:2004 Załącznik C"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (odważniki i wzorce masy)","regulatory_area_en":"Mass (weights and mass standards)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Masy, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Mass Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Wzorce masy i odważniki klasy dokładności F2 Wzorcowanie — Masa (odważniki i wzorce masy)\nZakres:\n1 mg, 2 mg, 5 mg CMC 0,020 mg\n10 mg CMC 0,025 mg\n20 mg CMC 0,03 mg\n50 mg CMC 0,04 mg\n100 mg CMC 0,05 mg\n200 mg CMC 0,06 mg\n500 mg CMC 0,08 mg\n1g CMC 0,10 mg\n2g CMC 0,13 mg\n5g CMC 0,15 mg\n10 g CMC 0,2 mg\n20 g CMC 0,25 mg\n50 g CMC 0,3 mg\n100 g CMC 0,5 mg\n200 g CMC 1,0 mg\n500 g CMC 2,5 mg\n1 kg CMC 5 mg\n2 kg CMC 10 mg\n5 kg CMC 25 mg\n10 kg CMC 50 mg\n20 kg CMC 100 mg\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW2/02 w oparciu o OIML R 111-1:2004 Załącznik C Wzorce masy i odwazniki klasy dokladnosci F2 Wzorcowanie — Masa (odwazniki i wzorce masy)\nZakres:\n1 mg, 2 mg, 5 mg CMC 0,020 mg\n10 mg CMC 0,025 mg\n20 mg CMC 0,03 mg\n50 mg CMC 0,04 mg\n100 mg CMC 0,05 mg\n200 mg CMC 0,06 mg\n500 mg CMC 0,08 mg\n1g CMC 0,10 mg\n2g CMC 0,13 mg\n5g CMC 0,15 mg\n10 g CMC 0,2 mg\n20 g CMC 0,25 mg\n50 g CMC 0,3 mg\n100 g CMC 0,5 mg\n200 g CMC 1,0 mg\n500 g CMC 2,5 mg\n1 kg CMC 5 mg\n2 kg CMC 10 mg\n5 kg CMC 25 mg\n10 kg CMC 50 mg\n20 kg CMC 100 mg\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW2/02 w oparciu o OIML R 111-1:2004 Zalacznik C","search_en":"Mass standards and weights of accuracy class F2 Calibration — Mass (weights and mass standards) Internal procedure; At permanent location (S) Mass (weights and mass standards) Internal procedure At permanent location (S) IW/LW2/02 based on OIML R 111-1:2004 Annex C","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":29,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"IW/LW2/02 based on OIML R 111-1:2004 Annex C","methodology_de":"Kalibrierung — Masse (Gewichtstücke und Massenormale)","reference_de":"IW/LW2/02 auf Grundlage von OIML R 111-1:2004 Anhang C","regulatory_area_de":"Masse (Gewichtstücke und Massenormale)","search_de":"Massenormale und Gewichtstücke der Genauigkeitsklasse F2 Kalibrierung — Masse (Gewichtstücke und Massenormale) Internes Verfahren; Am festen Standort (S) Masse (Gewichtstücke und Massenormale) Internes Verfahren Am festen Standort (S) IW/LW2/02 auf Grundlage von OIML R 111-1:2004 Anhang C","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Massenormale und Gewichtstücke der Genauigkeitsklasse F2","methodology_zh":"校准 — 质量（砝码和质量标准器）","reference_zh":"IW/LW2/02 依据OIML R 111-1:2004附录C","regulatory_area_zh":"质量（砝码和质量标准器）","search_zh":"精度等级为F2的质量标准器和砝码 校准 — 质量（砝码和质量标准器） 内部程序；在固定地点 (S) 质量（砝码和质量标准器） 内部程序 在固定地点 (S) IW/LW2/02 依据OIML R 111-1:2004附录C","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"精度等级为F2的质量标准器和砝码","methodology_cs":"Kalibrace — Hmotnost (závaží a etalony hmotnosti)","reference_cs":"IW/LW2/02 na základě OIML R 111-1:2004 Příloha C","regulatory_area_cs":"Hmotnost (závaží a etalony hmotnosti)","search_cs":"Etalony hmotnosti a závaží třídy přesnosti F2 Kalibrace — Hmotnost (závaží a etalony hmotnosti) Vnitřní postup; Ve stálé lokalitě (S) Hmotnost (závaží a etalony hmotnosti) Vnitřní postup Ve stálé lokalitě (S) IW/LW2/02 na základě OIML R 111-1:2004 Příloha C","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Etalony hmotnosti a závaží třídy přesnosti F2"},{"_id":"33fb4c1b7d895d7d3a6bada6","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Wzorce masy i odważniki klasy dokładności M1","test_object_en":"Mass standards and weights of accuracy class M1","methodology":"Wzorcowanie — Masa (odważniki i wzorce masy)","methodology_en":"Calibration — Mass (weights and mass standards)","parameters":[{"name":"","range":"1 mg, 2 mg, 5 mg","cmc":"0,06 mg"},{"name":"","range":"10 mg","cmc":"0,08 mg"},{"name":"","range":"20 mg","cmc":"0,10 mg"},{"name":"","range":"50 mg","cmc":"0,13 mg"},{"name":"","range":"100 mg","cmc":"0,15 mg"},{"name":"","range":"200 mg","cmc":"0,20 mg"},{"name":"","range":"500 mg","cmc":"0,25 mg"},{"name":"","range":"1g","cmc":"0,3 mg"},{"name":"","range":"2g","cmc":"0,4 mg"},{"name":"","range":"5g","cmc":"0,5 mg"},{"name":"","range":"10 g","cmc":"0,6 mg"},{"name":"","range":"20 g","cmc":"0,8 mg"},{"name":"","range":"50 g","cmc":"1,0 mg"},{"name":"","range":"100 g","cmc":"1,5 mg"},{"name":"","range":"200 g","cmc":"3 mg"},{"name":"","range":"500 g","cmc":"8 mg"},{"name":"","range":"1 kg","cmc":"15 mg"},{"name":"","range":"2 kg","cmc":"30 mg"},{"name":"","range":"5 kg","cmc":"80 mg"},{"name":"","range":"10 kg","cmc":"150 mg"},{"name":"","range":"20 kg","cmc":"300 mg"}],"parameters_en":[{"name":"","range":"1 mg, 2 mg, 5 mg","cmc":"0,06 mg"},{"name":"","range":"10 mg","cmc":"0,08 mg"},{"name":"","range":"20 mg","cmc":"0,10 mg"},{"name":"","range":"50 mg","cmc":"0,13 mg"},{"name":"","range":"100 mg","cmc":"0,15 mg"},{"name":"","range":"200 mg","cmc":"0,20 mg"},{"name":"","range":"500 mg","cmc":"0,25 mg"},{"name":"","range":"1g","cmc":"0,3 mg"},{"name":"","range":"2g","cmc":"0,4 mg"},{"name":"","range":"5g","cmc":"0,5 mg"},{"name":"","range":"10 g","cmc":"0,6 mg"},{"name":"","range":"20 g","cmc":"0,8 mg"},{"name":"","range":"50 g","cmc":"1,0 mg"},{"name":"","range":"100 g","cmc":"1,5 mg"},{"name":"","range":"200 g","cmc":"3 mg"},{"name":"","range":"500 g","cmc":"8 mg"},{"name":"","range":"1 kg","cmc":"15 mg"},{"name":"","range":"2 kg","cmc":"30 mg"},{"name":"","range":"5 kg","cmc":"80 mg"},{"name":"","range":"10 kg","cmc":"150 mg"},{"name":"","range":"20 kg","cmc":"300 mg"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (odważniki i wzorce masy)\nZakres:\n1 mg, 2 mg, 5 mg CMC 0,06 mg\n10 mg CMC 0,08 mg\n20 mg CMC 0,10 mg\n50 mg CMC 0,13 mg\n100 mg CMC 0,15 mg\n200 mg CMC 0,20 mg\n500 mg CMC 0,25 mg\n1g CMC 0,3 mg\n2g CMC 0,4 mg\n5g CMC 0,5 mg\n10 g CMC 0,6 mg\n20 g CMC 0,8 mg\n50 g CMC 1,0 mg\n100 g CMC 1,5 mg\n200 g CMC 3 mg\n500 g CMC 8 mg\n1 kg CMC 15 mg\n2 kg CMC 30 mg\n5 kg CMC 80 mg\n10 kg CMC 150 mg\n20 kg CMC 300 mg\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW2/02 w oparciu o OIML R 111-1:2004 Załącznik C","norm_bases":["IW/LW2/02","OIML R 111-1:2004 Załącznik C"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (odważniki i wzorce masy)","regulatory_area_en":"Mass (weights and mass standards)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Masy, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Mass Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Wzorce masy i odważniki klasy dokładności M1 Wzorcowanie — Masa (odważniki i wzorce masy)\nZakres:\n1 mg, 2 mg, 5 mg CMC 0,06 mg\n10 mg CMC 0,08 mg\n20 mg CMC 0,10 mg\n50 mg CMC 0,13 mg\n100 mg CMC 0,15 mg\n200 mg CMC 0,20 mg\n500 mg CMC 0,25 mg\n1g CMC 0,3 mg\n2g CMC 0,4 mg\n5g CMC 0,5 mg\n10 g CMC 0,6 mg\n20 g CMC 0,8 mg\n50 g CMC 1,0 mg\n100 g CMC 1,5 mg\n200 g CMC 3 mg\n500 g CMC 8 mg\n1 kg CMC 15 mg\n2 kg CMC 30 mg\n5 kg CMC 80 mg\n10 kg CMC 150 mg\n20 kg CMC 300 mg\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW2/02 w oparciu o OIML R 111-1:2004 Załącznik C Wzorce masy i odwazniki klasy dokladnosci M1 Wzorcowanie — Masa (odwazniki i wzorce masy)\nZakres:\n1 mg, 2 mg, 5 mg CMC 0,06 mg\n10 mg CMC 0,08 mg\n20 mg CMC 0,10 mg\n50 mg CMC 0,13 mg\n100 mg CMC 0,15 mg\n200 mg CMC 0,20 mg\n500 mg CMC 0,25 mg\n1g CMC 0,3 mg\n2g CMC 0,4 mg\n5g CMC 0,5 mg\n10 g CMC 0,6 mg\n20 g CMC 0,8 mg\n50 g CMC 1,0 mg\n100 g CMC 1,5 mg\n200 g CMC 3 mg\n500 g CMC 8 mg\n1 kg CMC 15 mg\n2 kg CMC 30 mg\n5 kg CMC 80 mg\n10 kg CMC 150 mg\n20 kg CMC 300 mg\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW2/02 w oparciu o OIML R 111-1:2004 Zalacznik C","search_en":"Mass standards and weights of accuracy class M1 Calibration — Mass (weights and mass standards) Internal procedure; At permanent location (S) Mass (weights and mass standards) Internal procedure At permanent location (S) IW/LW2/02 based on OIML R 111-1:2004 Annex C","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":30,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"IW/LW2/02 based on OIML R 111-1:2004 Annex C","methodology_de":"Kalibrierung — Masse (Gewichtstücke und Massenormale)","reference_de":"IW/LW2/02 auf Grundlage von OIML R 111-1:2004 Anhang C","regulatory_area_de":"Masse (Gewichtstücke und Massenormale)","search_de":"Massenormale und Gewichtstücke der Genauigkeitsklasse M1 Kalibrierung — Masse (Gewichtstücke und Massenormale) Internes Verfahren; Am festen Standort (S) Masse (Gewichtstücke und Massenormale) Internes Verfahren Am festen Standort (S) IW/LW2/02 auf Grundlage von OIML R 111-1:2004 Anhang C","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Massenormale und Gewichtstücke der Genauigkeitsklasse M1","methodology_zh":"校准 — 质量（砝码和质量标准器）","reference_zh":"IW/LW2/02 依据OIML R 111-1:2004附录C","regulatory_area_zh":"质量（砝码和质量标准器）","search_zh":"精度等级为M1的质量标准器和砝码 校准 — 质量（砝码和质量标准器） 内部程序；在固定地点 (S) 质量（砝码和质量标准器） 内部程序 在固定地点 (S) IW/LW2/02 依据OIML R 111-1:2004附录C","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"精度等级为M1的质量标准器和砝码","methodology_cs":"Kalibrace — Hmotnost (závaží a etalony hmotnosti)","reference_cs":"IW/LW2/02 na základě OIML R 111-1:2004 Příloha C","regulatory_area_cs":"Hmotnost (závaží a etalony hmotnosti)","search_cs":"Etalony hmotnosti a závaží třídy přesnosti M1 Kalibrace — Hmotnost (závaží a etalony hmotnosti) Vnitřní postup; Ve stálé lokalitě (S) Hmotnost (závaží a etalony hmotnosti) Vnitřní postup Ve stálé lokalitě (S) IW/LW2/02 na základě OIML R 111-1:2004 Příloha C","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Etalony hmotnosti a závaží třídy přesnosti M1"},{"_id":"ba33a591b18d311624acd6e2","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Wzorce masy 25 kg","test_object_en":"25 kg mass standards","methodology":"Wzorcowanie — Masa (odważniki i wzorce masy)","methodology_en":"Calibration — Mass (weights and mass standards)","parameters":[{"name":"","range":"25 kg","cmc":"380 mg"}],"parameters_en":[{"name":"","range":"25 kg","cmc":"380 mg"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (odważniki i wzorce masy)\n25 kg CMC 380 mg\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW2/02 w oparciu o OIML R 111-1:2004 Załącznik C","norm_bases":["IW/LW2/02","OIML R 111-1:2004 Załącznik C"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (odważniki i wzorce masy)","regulatory_area_en":"Mass (weights and mass standards)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Masy, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Mass Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Wzorce masy 25 kg Wzorcowanie — Masa (odważniki i wzorce masy)\n25 kg CMC 380 mg\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW2/02 w oparciu o OIML R 111-1:2004 Załącznik C Wzorce masy 25 kg Wzorcowanie — Masa (odwazniki i wzorce masy)\n25 kg CMC 380 mg\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW2/02 w oparciu o OIML R 111-1:2004 Zalacznik C","search_en":"25 kg mass standards Calibration — Mass (weights and mass standards) Internal procedure; At permanent location (S) Mass (weights and mass standards) Internal procedure At permanent location (S) IW/LW2/02 based on OIML R 111-1:2004 Annex C","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":31,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"IW/LW2/02 based on OIML R 111-1:2004 Annex C","methodology_de":"Kalibrierung — Masse (Gewichtstücke und Massenormale)","reference_de":"IW/LW2/02 auf Grundlage von OIML R 111-1:2004 Anhang C","regulatory_area_de":"Masse (Gewichtstücke und Massenormale)","search_de":"Massenormale 25 kg Kalibrierung — Masse (Gewichtstücke und Massenormale) Internes Verfahren; Am festen Standort (S) Masse (Gewichtstücke und Massenormale) Internes Verfahren Am festen Standort (S) IW/LW2/02 auf Grundlage von OIML R 111-1:2004 Anhang C","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Massenormale 25 kg","methodology_zh":"校准 — 质量（砝码和质量标准器）","reference_zh":"IW/LW2/02 依据OIML R 111-1:2004附录C","regulatory_area_zh":"质量（砝码和质量标准器）","search_zh":"25 kg 质量标准器 校准 — 质量（砝码和质量标准器） 内部程序；在固定地点 (S) 质量（砝码和质量标准器） 内部程序 在固定地点 (S) IW/LW2/02 依据OIML R 111-1:2004附录C","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"25 kg 质量标准器","methodology_cs":"Kalibrace — Hmotnost (závaží a etalony hmotnosti)","reference_cs":"IW/LW2/02 na základě OIML R 111-1:2004 Příloha C","regulatory_area_cs":"Hmotnost (závaží a etalony hmotnosti)","search_cs":"Etalony hmotnosti 25 kg Kalibrace — Hmotnost (závaží a etalony hmotnosti) Vnitřní postup; Ve stálé lokalitě (S) Hmotnost (závaží a etalony hmotnosti) Vnitřní postup Ve stálé lokalitě (S) IW/LW2/02 na základě OIML R 111-1:2004 Příloha C","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Etalony hmotnosti 25 kg"},{"_id":"a95d1efd3adb5cfd24b6beaa","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Klucze dynamometryczne\nWkrętaki dynamometryczne","test_object_en":"Torque wrenches\nTorque screwdrivers","methodology":"Wzorcowanie — Moment siły","methodology_en":"Calibration — Torque","parameters":[{"name":"","range":"0,04 Nm do 1500 Nm","cmc":"0,5 %"}],"parameters_en":[{"name":"","range":"0,04 Nm to 1500 Nm","cmc":"0,5 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moment siły\n0,04 Nm do 1500 Nm CMC 0,5 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW2/04 w oparciu o PN-EN ISO 6789-1:2017\nPN-EN ISO 6789-2:2017","norm_bases":["IW/LW2/04","PN-EN ISO 6789-1:2017","PN-EN ISO 6789-2:2017"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moment siły","regulatory_area_en":"Torque","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Masy, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Mass Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Klucze dynamometryczne\nWkrętaki dynamometryczne Wzorcowanie — Moment siły\n0,04 Nm do 1500 Nm CMC 0,5 %\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW2/04 w oparciu o PN-EN ISO 6789-1:2017\nPN-EN ISO 6789-2:2017 Klucze dynamometryczne\nWkretaki dynamometryczne Wzorcowanie — Moment sily\n0,04 Nm do 1500 Nm CMC 0,5 %\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW2/04 w oparciu o PN-EN ISO 6789-1:2017\nPN-EN ISO 6789-2:2017","search_en":"Torque wrenches Torque screwdrivers Calibration — Torque Internal procedure; At permanent location (S) Torque Internal procedure At permanent location (S) IW/LW2/04 based on PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":32,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"IW/LW2/04 based on PN-EN ISO 6789-1:2017\nPN-EN ISO 6789-2:2017","methodology_de":"Kalibrierung — Drehmoment","parameters_de":[{"name":"","range":"0,04 Nm to 1500 Nm","cmc":"0,5 %"}],"reference_de":"IW/LW2/04 auf Grundlage von PN-EN ISO 6789-1:2017\nPN-EN ISO 6789-2:2017","regulatory_area_de":"Drehmoment","search_de":"Drehmomentschlüssel Drehmomentschraubendreher Kalibrierung — Drehmoment Internes Verfahren; Am festen Standort (S) Drehmoment Internes Verfahren Am festen Standort (S) IW/LW2/04 auf Grundlage von PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Drehmomentschlüssel\nDrehmomentschraubendreher","methodology_zh":"校准 — 力矩","parameters_zh":[{"name":"","range":"0,04 Nm to 1500 Nm","cmc":"0,5 %"}],"reference_zh":"IW/LW2/04 依据PN-EN ISO 6789-1:2017\nPN-EN ISO 6789-2:2017","regulatory_area_zh":"力矩","search_zh":"扭矩扳手 扭矩螺丝刀 校准 — 力矩 内部程序；在固定地点 (S) 力矩 内部程序 在固定地点 (S) IW/LW2/04 依据PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"扭矩扳手\n扭矩螺丝刀","methodology_cs":"Kalibrace — Moment síly","parameters_cs":[{"name":"","range":"0,04 Nm to 1500 Nm","cmc":"0,5 %"}],"reference_cs":"IW/LW2/04 na základě PN-EN ISO 6789-1:2017\nPN-EN ISO 6789-2:2017","regulatory_area_cs":"Moment síly","search_cs":"Momentové klíče Momentové šroubováky Kalibrace — Moment síly Vnitřní postup; Ve stálé lokalitě (S) Moment síly Vnitřní postup Ve stálé lokalitě (S) IW/LW2/04 na základě PN-EN ISO 6789-1:2017 PN-EN ISO 6789-2:2017","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Momentové klíče\nMomentové šroubováky"},{"_id":"c69c4f46eeab68b2f0997d4b","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Pehametry","test_object_en":"pH meters","methodology":"Wzorcowanie — pH","methodology_en":"Calibration — pH","parameters":[{"name":"- pH","range":"0 do 14","cmc":"0,003"},{"name":"- napięcia stałe","range":"-1400 mV do 1400 mV","cmc":"0,2 mV"}],"parameters_en":[{"name":"pH","range":"0 to 14","cmc":"0,003"},{"name":"DC voltage","range":"-1400 mV to 1400 mV","cmc":"0,2 mV"}],"technique":"Procedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S)","technique_en":"Internal procedure; Electrical method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda elektryczna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Electrical method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — pH\nZakres:\n- pH 0 do 14 CMC 0,003\n- napięcia stałe -1400 mV do 1400 mV CMC 0,2 mV\nProcedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S)","reference":"IW/LW3/11","norm_bases":["IW/LW3/11"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"pH","regulatory_area_en":"pH","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Pehametry Wzorcowanie — pH\nZakres:\n- pH 0 do 14 CMC 0,003\n- napięcia stałe -1400 mV do 1400 mV CMC 0,2 mV\nProcedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S) IW/LW3/11 Pehametry Wzorcowanie — pH\nZakres:\n- pH 0 do 14 CMC 0,003\n- napiecia stale -1400 mV do 1400 mV CMC 0,2 mV\nProcedura wewnetrzna; Metoda elektryczna; W stalej lokalizacji (S) IW/LW3/11","search_en":"pH meters Calibration — pH Internal procedure; Electrical method; At permanent location (S) pH Internal procedure Electrical method At permanent location (S) pH DC voltage IW/LW3/11","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":33,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — pH","parameters_de":[{"name":"- pH","range":"0 to 14","cmc":"0,003"},{"name":"- Gleichspannungen","range":"-1400 mV to 1400 mV","cmc":"0,2 mV"}],"regulatory_area_de":"pH","search_de":"pH-Meter Kalibrierung — pH Internes Verfahren; Elektrisches Verfahren; Am festen Standort (S) pH Internes Verfahren Elektrisches Verfahren Am festen Standort (S) - pH - Gleichspannungen IW/LW3/11","technique_de":"Internes Verfahren; Elektrisches Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Elektrisches Verfahren","Am festen Standort (S)"],"test_object_de":"pH-Meter","methodology_zh":"校准 — pH","parameters_zh":[{"name":"- pH","range":"0 to 14","cmc":"0,003"},{"name":"- 直流电压","range":"-1400 mV to 1400 mV","cmc":"0,2 mV"}],"regulatory_area_zh":"pH 值","search_zh":"pH 计 校准 — pH 内部程序；电学法；在固定地点 (S) pH 值 内部程序 电学法 在固定地点 (S) - pH - 直流电压 IW/LW3/11","technique_zh":"内部程序；电学法；在固定地点 (S)","techniques_zh":["内部程序","电学法","在固定地点 (S)"],"test_object_zh":"pH 计","methodology_cs":"Kalibrace — pH","parameters_cs":[{"name":"- pH","range":"0 to 14","cmc":"0,003"},{"name":"- stejnosměrná napětí","range":"-1400 mV to 1400 mV","cmc":"0,2 mV"}],"regulatory_area_cs":"pH","search_cs":"pH metry Kalibrace — pH Vnitřní postup; Elektrická metoda; Ve stálé lokalitě (S) pH Vnitřní postup Elektrická metoda Ve stálé lokalitě (S) - pH - stejnosměrná napětí IW/LW3/11","technique_cs":"Vnitřní postup; Elektrická metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Elektrická metoda","Ve stálé lokalitě (S)"],"test_object_cs":"pH metry"},{"_id":"ed592f4d82956d718e3404b3","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Pehametry\nElektrody pehametryczne","test_object_en":"pH meters\npH electrodes","methodology":"Wzorcowanie — pH","methodology_en":"Calibration — pH","parameters":[{"name":"- pH","range":"1,00 do 11,00","cmc":"0,04"},{"name":"- pH","range":"11,01 do 13,00","cmc":"0,3"},{"name":"- nachylenie charakterystyki","range":"40,0 mV do 80,0 mV","cmc":"0,4 mV"},{"name":"- sprawność elektrody β","range":"75,0 % do 102,0 %","cmc":"0,8 %"},{"name":"- punkt zerowy (pH dla E=0 mV)","range":"2,00 do 10,00","cmc":"0,03"}],"parameters_en":[{"name":"pH","range":"1,00 to 11,00","cmc":"0,04"},{"name":"pH","range":"11,01 to 13,00","cmc":"0,3"},{"name":"slope of the characteristic","range":"40,0 mV to 80,0 mV","cmc":"0,4 mV"},{"name":"electrode efficiency β","range":"75,0 % to 102,0 %","cmc":"0,8 %"},{"name":"zero point (pH for E=0 mV)","range":"2,00 to 10,00","cmc":"0,03"}],"technique":"Procedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Method using reference materials; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda z zastosowaniem materiałów odniesienia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Method using reference materials","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — pH\nZakres:\n- pH 1,00 do 11,00 CMC 0,04\n- pH 11,01 do 13,00 CMC 0,3\n- nachylenie charakterystyki 40,0 mV do 80,0 mV CMC 0,4 mV\n- sprawność elektrody β 75,0 % do 102,0 % CMC 0,8 %\n- punkt zerowy (pH dla E=0 mV) 2,00 do 10,00 CMC 0,03\nProcedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S)","reference":"IW/LW3/19","norm_bases":["IW/LW3/19"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"pH","regulatory_area_en":"pH","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Pehametry\nElektrody pehametryczne Wzorcowanie — pH\nZakres:\n- pH 1,00 do 11,00 CMC 0,04\n- pH 11,01 do 13,00 CMC 0,3\n- nachylenie charakterystyki 40,0 mV do 80,0 mV CMC 0,4 mV\n- sprawność elektrody β 75,0 % do 102,0 % CMC 0,8 %\n- punkt zerowy (pH dla E=0 mV) 2,00 do 10,00 CMC 0,03\nProcedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S) IW/LW3/19 Pehametry\nElektrody pehametryczne Wzorcowanie — pH\nZakres:\n- pH 1,00 do 11,00 CMC 0,04\n- pH 11,01 do 13,00 CMC 0,3\n- nachylenie charakterystyki 40,0 mV do 80,0 mV CMC 0,4 mV\n- sprawnosc elektrody β 75,0 % do 102,0 % CMC 0,8 %\n- punkt zerowy (pH dla E=0 mV) 2,00 do 10,00 CMC 0,03\nProcedura wewnetrzna; Metoda z zastosowaniem materialow odniesienia; W stalej lokalizacji (S) IW/LW3/19","search_en":"pH meters pH electrodes Calibration — pH Internal procedure; Method using reference materials; At permanent location (S) pH Internal procedure Method using reference materials At permanent location (S) pH pH slope of the characteristic electrode efficiency β zero point (pH for E=0 mV) IW/LW3/19","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":34,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — pH","parameters_de":[{"name":"- pH","range":"1,00 to 11,00","cmc":"0,04"},{"name":"- pH","range":"11,01 to 13,00","cmc":"0,3"},{"name":"- Steilheit der Kennlinie","range":"40,0 mV to 80,0 mV","cmc":"0,4 mV"},{"name":"- Elektrodenwirkungsgrad β","range":"75,0 % to 102,0 %","cmc":"0,8 %"},{"name":"- Nullpunkt (pH für E=0 mV)","range":"2,00 to 10,00","cmc":"0,03"}],"regulatory_area_de":"pH","search_de":"pH-Meter pH-Elektroden Kalibrierung — pH Internes Verfahren; Verfahren mit Referenzmaterialien; Am festen Standort (S) pH Internes Verfahren Verfahren mit Referenzmaterialien Am festen Standort (S) - pH - pH - Steilheit der Kennlinie - Elektrodenwirkungsgrad β - Nullpunkt (pH für E=0 mV) IW/LW3/19","technique_de":"Internes Verfahren; Verfahren mit Referenzmaterialien; Am festen Standort (S)","techniques_de":["Internes Verfahren","Verfahren mit Referenzmaterialien","Am festen Standort (S)"],"test_object_de":"pH-Meter\npH-Elektroden","methodology_zh":"校准 — pH","parameters_zh":[{"name":"- pH","range":"1,00 to 11,00","cmc":"0,04"},{"name":"- pH","range":"11,01 to 13,00","cmc":"0,3"},{"name":"- 特性曲线斜率","range":"40,0 mV to 80,0 mV","cmc":"0,4 mV"},{"name":"- 电极效率 β","range":"75,0 % to 102,0 %","cmc":"0,8 %"},{"name":"- 零点（E=0 mV 时的 pH）","range":"2,00 to 10,00","cmc":"0,03"}],"regulatory_area_zh":"pH 值","search_zh":"pH 计 pH电极 校准 — pH 内部程序；使用参考物质的方法；在固定地点 (S) pH 值 内部程序 使用参考物质的方法 在固定地点 (S) - pH - pH - 特性曲线斜率 - 电极效率 β - 零点（E=0 mV 时的 pH） IW/LW3/19","technique_zh":"内部程序；使用参考物质的方法；在固定地点 (S)","techniques_zh":["内部程序","使用参考物质的方法","在固定地点 (S)"],"test_object_zh":"pH 计\npH电极","methodology_cs":"Kalibrace — pH","parameters_cs":[{"name":"- pH","range":"1,00 to 11,00","cmc":"0,04"},{"name":"- pH","range":"11,01 to 13,00","cmc":"0,3"},{"name":"- strmost charakteristiky","range":"40,0 mV to 80,0 mV","cmc":"0,4 mV"},{"name":"- účinnost elektrody β","range":"75,0 % to 102,0 %","cmc":"0,8 %"},{"name":"- nulový bod (pH pro E=0 mV)","range":"2,00 to 10,00","cmc":"0,03"}],"regulatory_area_cs":"pH","search_cs":"pH metry pH elektrody Kalibrace — pH Vnitřní postup; Metoda s použitím referenčních materiálů; Ve stálé lokalitě (S) pH Vnitřní postup Metoda s použitím referenčních materiálů Ve stálé lokalitě (S) - pH - pH - strmost charakteristiky - účinnost elektrody β - nulový bod (pH pro E=0 mV) IW/LW3/19","technique_cs":"Vnitřní postup; Metoda s použitím referenčních materiálů; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Metoda s použitím referenčních materiálů","Ve stálé lokalitě (S)"],"test_object_cs":"pH metry\npH elektrody"},{"_id":"810b11d2e6e7cbfb3e496916","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Konduktometry","test_object_en":"Conductivity meters","methodology":"Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)","methodology_en":"Calibration — Specific electrical conductivity (conductometry)","parameters":[{"name":"","range":"0,1 µS∙cm⁻¹ do 2 µS∙cm⁻¹","cmc":"0,002 µS∙cm⁻¹"},{"name":"","range":"0,002 mS∙cm⁻¹ do 100 mS∙cm⁻¹","cmc":"0,09 %"},{"name":"","range":"100 mS∙cm⁻¹ do 200 mS∙cm⁻¹","cmc":"0,13 %"}],"parameters_en":[{"name":"","range":"0,1 µS∙cm⁻¹ to 2 µS∙cm⁻¹","cmc":"0,002 µS∙cm⁻¹"},{"name":"","range":"0,002 mS∙cm⁻¹ to 100 mS∙cm⁻¹","cmc":"0,09 %"},{"name":"","range":"100 mS∙cm⁻¹ to 200 mS∙cm⁻¹","cmc":"0,13 %"}],"technique":"Procedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S)","technique_en":"Internal procedure; Electrical method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda elektryczna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Electrical method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)\nZakres:\n0,1 µS∙cm⁻¹ do 2 µS∙cm⁻¹ CMC 0,002 µS∙cm⁻¹\n0,002 mS∙cm⁻¹ do 100 mS∙cm⁻¹ CMC 0,09 %\n100 mS∙cm⁻¹ do 200 mS∙cm⁻¹ CMC 0,13 %\nProcedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S)","reference":"IW/LW3/12","norm_bases":["IW/LW3/12"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Przewodność elektryczna właściwa (konduktometria)","regulatory_area_en":"Specific electrical conductivity (conductometry)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Konduktometry Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)\nZakres:\n0,1 µS∙cm⁻¹ do 2 µS∙cm⁻¹ CMC 0,002 µS∙cm⁻¹\n0,002 mS∙cm⁻¹ do 100 mS∙cm⁻¹ CMC 0,09 %\n100 mS∙cm⁻¹ do 200 mS∙cm⁻¹ CMC 0,13 %\nProcedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S) IW/LW3/12 Konduktometry Wzorcowanie — Przewodnosc elektryczna wlasciwa (konduktometria)\nZakres:\n0,1 µS∙cm⁻¹ do 2 µS∙cm⁻¹ CMC 0,002 µS∙cm⁻¹\n0,002 mS∙cm⁻¹ do 100 mS∙cm⁻¹ CMC 0,09 %\n100 mS∙cm⁻¹ do 200 mS∙cm⁻¹ CMC 0,13 %\nProcedura wewnetrzna; Metoda elektryczna; W stalej lokalizacji (S) IW/LW3/12","search_en":"Conductivity meters Calibration — Specific electrical conductivity (conductometry) Internal procedure; Electrical method; At permanent location (S) Specific electrical conductivity (conductometry) Internal procedure Electrical method At permanent location (S) IW/LW3/12","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":35,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Elektrische Leitfähigkeit (Konduktometrie)","parameters_de":[{"name":"","range":"0,1 µS∙cm⁻¹ to 2 µS∙cm⁻¹","cmc":"0,002 µS∙cm⁻¹"},{"name":"","range":"0,002 mS∙cm⁻¹ to 100 mS∙cm⁻¹","cmc":"0,09 %"},{"name":"","range":"100 mS∙cm⁻¹ to 200 mS∙cm⁻¹","cmc":"0,13 %"}],"regulatory_area_de":"Spezifische elektrische Leitfähigkeit (Konduktometrie)","search_de":"Leitfähigkeitsmessgeräte Kalibrierung — Elektrische Leitfähigkeit (Konduktometrie) Internes Verfahren; Elektrisches Verfahren; Am festen Standort (S) Spezifische elektrische Leitfähigkeit (Konduktometrie) Internes Verfahren Elektrisches Verfahren Am festen Standort (S) IW/LW3/12","technique_de":"Internes Verfahren; Elektrisches Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Elektrisches Verfahren","Am festen Standort (S)"],"test_object_de":"Leitfähigkeitsmessgeräte","methodology_zh":"校准 — 电导率（电导法）","parameters_zh":[{"name":"","range":"0,1 µS∙cm⁻¹ to 2 µS∙cm⁻¹","cmc":"0,002 µS∙cm⁻¹"},{"name":"","range":"0,002 mS∙cm⁻¹ to 100 mS∙cm⁻¹","cmc":"0,09 %"},{"name":"","range":"100 mS∙cm⁻¹ to 200 mS∙cm⁻¹","cmc":"0,13 %"}],"regulatory_area_zh":"电导率（电导法）","search_zh":"电导率仪 校准 — 电导率（电导法） 内部程序；电学法；在固定地点 (S) 电导率（电导法） 内部程序 电学法 在固定地点 (S) IW/LW3/12","technique_zh":"内部程序；电学法；在固定地点 (S)","techniques_zh":["内部程序","电学法","在固定地点 (S)"],"test_object_zh":"电导率仪","methodology_cs":"Kalibrace — Měrná elektrická vodivost (konduktometrie)","parameters_cs":[{"name":"","range":"0,1 µS∙cm⁻¹ to 2 µS∙cm⁻¹","cmc":"0,002 µS∙cm⁻¹"},{"name":"","range":"0,002 mS∙cm⁻¹ to 100 mS∙cm⁻¹","cmc":"0,09 %"},{"name":"","range":"100 mS∙cm⁻¹ to 200 mS∙cm⁻¹","cmc":"0,13 %"}],"regulatory_area_cs":"Měrná elektrická vodivost (konduktometrie)","search_cs":"Konduktometry Kalibrace — Měrná elektrická vodivost (konduktometrie) Vnitřní postup; Elektrická metoda; Ve stálé lokalitě (S) Měrná elektrická vodivost (konduktometrie) Vnitřní postup Elektrická metoda Ve stálé lokalitě (S) IW/LW3/12","technique_cs":"Vnitřní postup; Elektrická metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Elektrická metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Konduktometry"},{"_id":"6455c8439c93c628beca173d","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Multimetry\nMierniki napięcia cyfrowe\nMierniki napięcia analogowe\nMierniki parametrów sieci energetycznych","test_object_en":"Multimeters\nDigital voltmeters\nAnalogue voltmeters\nPower quality meters","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"100 µV do 1 mV","cmc":"0,064 %"},{"name":"","range":"1 mV do 100 mV","cmc":"0,0015 %"},{"name":"","range":"100 mV do 1 V","cmc":"0,00076 %"},{"name":"","range":"1 V do 10 V","cmc":"0,00044 %"},{"name":"","range":"10 V do 100 V","cmc":"0,00077 %"},{"name":"","range":"100 V do 1000 V","cmc":"0,00088 %"}],"parameters_en":[{"name":"","range":"100 µV to 1 mV","cmc":"0,064 %"},{"name":"","range":"1 mV to 100 mV","cmc":"0,0015 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,00076 %"},{"name":"","range":"1 V to 10 V","cmc":"0,00044 %"},{"name":"","range":"10 V to 100 V","cmc":"0,00077 %"},{"name":"","range":"100 V to 1000 V","cmc":"0,00088 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n100 µV do 1 mV CMC 0,064 %\n1 mV do 100 mV CMC 0,0015 %\n100 mV do 1 V CMC 0,00076 %\n1 V do 10 V CMC 0,00044 %\n10 V do 100 V CMC 0,00077 %\n100 V do 1000 V CMC 0,00088 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/02\nIW/LW3/09\nIW/LW3/18","norm_bases":["IW/LW3/02","IW/LW3/09","IW/LW3/18"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Multimetry\nMierniki napięcia cyfrowe\nMierniki napięcia analogowe\nMierniki parametrów sieci energetycznych Wzorcowanie — Napięcie DC\nZakres:\n100 µV do 1 mV CMC 0,064 %\n1 mV do 100 mV CMC 0,0015 %\n100 mV do 1 V CMC 0,00076 %\n1 V do 10 V CMC 0,00044 %\n10 V do 100 V CMC 0,00077 %\n100 V do 1000 V CMC 0,00088 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/02\nIW/LW3/09\nIW/LW3/18 Multimetry\nMierniki napiecia cyfrowe\nMierniki napiecia analogowe\nMierniki parametrow sieci energetycznych Wzorcowanie — Napiecie DC\nZakres:\n100 µV do 1 mV CMC 0,064 %\n1 mV do 100 mV CMC 0,0015 %\n100 mV do 1 V CMC 0,00076 %\n1 V do 10 V CMC 0,00044 %\n10 V do 100 V CMC 0,00077 %\n100 V do 1000 V CMC 0,00088 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/02\nIW/LW3/09\nIW/LW3/18","search_en":"Multimeters Digital voltmeters Analogue voltmeters Power quality meters Calibration — DC voltage Internal procedure; Direct method; At permanent location (S) DC voltage Internal procedure Direct method At permanent location (S) IW/LW3/02 IW/LW3/09 IW/LW3/18","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":36,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"100 µV to 1 mV","cmc":"0,064 %"},{"name":"","range":"1 mV to 100 mV","cmc":"0,0015 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,00076 %"},{"name":"","range":"1 V to 10 V","cmc":"0,00044 %"},{"name":"","range":"10 V to 100 V","cmc":"0,00077 %"},{"name":"","range":"100 V to 1000 V","cmc":"0,00088 %"}],"regulatory_area_de":"DC-Spannung","search_de":"Multimeter Digitale Spannungsmessgeräte Analoge Spannungsmessgeräte Netzanalysatoren für Energienetze Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) IW/LW3/02 IW/LW3/09 IW/LW3/18","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter\nDigitale Spannungsmessgeräte\nAnaloge Spannungsmessgeräte\nNetzanalysatoren für Energienetze","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"100 µV to 1 mV","cmc":"0,064 %"},{"name":"","range":"1 mV to 100 mV","cmc":"0,0015 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,00076 %"},{"name":"","range":"1 V to 10 V","cmc":"0,00044 %"},{"name":"","range":"10 V to 100 V","cmc":"0,00077 %"},{"name":"","range":"100 V to 1000 V","cmc":"0,00088 %"}],"regulatory_area_zh":"直流电压","search_zh":"万用表 数字电压表 模拟电压表 电网参数测量仪 校准 — 直流电压 内部程序；直接法；在固定地点 (S) 直流电压 内部程序 直接法 在固定地点 (S) IW/LW3/02 IW/LW3/09 IW/LW3/18","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"万用表\n数字电压表\n模拟电压表\n电网参数测量仪","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"100 µV to 1 mV","cmc":"0,064 %"},{"name":"","range":"1 mV to 100 mV","cmc":"0,0015 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,00076 %"},{"name":"","range":"1 V to 10 V","cmc":"0,00044 %"},{"name":"","range":"10 V to 100 V","cmc":"0,00077 %"},{"name":"","range":"100 V to 1000 V","cmc":"0,00088 %"}],"regulatory_area_cs":"Napětí DC","search_cs":"Multimetry Digitální měřiče napětí Analogové měřiče napětí Měřiče parametrů energetické sítě Kalibrace — Napětí DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Napětí DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) IW/LW3/02 IW/LW3/09 IW/LW3/18","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry\nDigitální měřiče napětí\nAnalogové měřiče napětí\nMěřiče parametrů energetické sítě"},{"_id":"509d7d7622a5b4dacfd7e2fa","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Kalibratory\nZasilacze","test_object_en":"Calibrators\nPower supplies","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"100 µV do 100 mV","cmc":"0,0012 %"},{"name":"","range":"100 mV do 1 V","cmc":"0,00073 %"},{"name":"","range":"1 V do 10 V","cmc":"0,00078 %"},{"name":"","range":"10 V do 1000 V","cmc":"0,0013 %"}],"parameters_en":[{"name":"","range":"100 µV to 100 mV","cmc":"0,0012 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,00073 %"},{"name":"","range":"1 V to 10 V","cmc":"0,00078 %"},{"name":"","range":"10 V to 1000 V","cmc":"0,0013 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n100 µV do 100 mV CMC 0,0012 %\n100 mV do 1 V CMC 0,00073 %\n1 V do 10 V CMC 0,00078 %\n10 V do 1000 V CMC 0,0013 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/01\nIW/LW3/16","norm_bases":["IW/LW3/01","IW/LW3/16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Kalibratory\nZasilacze Wzorcowanie — Napięcie DC\nZakres:\n100 µV do 100 mV CMC 0,0012 %\n100 mV do 1 V CMC 0,00073 %\n1 V do 10 V CMC 0,00078 %\n10 V do 1000 V CMC 0,0013 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/01\nIW/LW3/16 Kalibratory\nZasilacze Wzorcowanie — Napiecie DC\nZakres:\n100 µV do 100 mV CMC 0,0012 %\n100 mV do 1 V CMC 0,00073 %\n1 V do 10 V CMC 0,00078 %\n10 V do 1000 V CMC 0,0013 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/01\nIW/LW3/16","search_en":"Calibrators Power supplies Calibration — DC voltage Internal procedure; Direct method; At permanent location (S) DC voltage Internal procedure Direct method At permanent location (S) IW/LW3/01 IW/LW3/16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":37,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"100 µV to 100 mV","cmc":"0,0012 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,00073 %"},{"name":"","range":"1 V to 10 V","cmc":"0,00078 %"},{"name":"","range":"10 V to 1000 V","cmc":"0,0013 %"}],"regulatory_area_de":"DC-Spannung","search_de":"Kalibratoren Netzgeräte Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) IW/LW3/01 IW/LW3/16","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"100 µV to 100 mV","cmc":"0,0012 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,00073 %"},{"name":"","range":"1 V to 10 V","cmc":"0,00078 %"},{"name":"","range":"10 V to 1000 V","cmc":"0,0013 %"}],"regulatory_area_zh":"直流电压","search_zh":"校准器 电源 校准 — 直流电压 内部程序；直接法；在固定地点 (S) 直流电压 内部程序 直接法 在固定地点 (S) IW/LW3/01 IW/LW3/16","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"校准器\n电源","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"100 µV to 100 mV","cmc":"0,0012 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,00073 %"},{"name":"","range":"1 V to 10 V","cmc":"0,00078 %"},{"name":"","range":"10 V to 1000 V","cmc":"0,0013 %"}],"regulatory_area_cs":"Napětí DC","search_cs":"Kalibrátory Napájecí zdroje Kalibrace — Napětí DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Napětí DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) IW/LW3/01 IW/LW3/16","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nNapájecí zdroje"},{"_id":"d2adde7d5faa9c532b6c8dae","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Multimetry\nMierniki prądu cyfrowe\nMierniki prądu analogowe\nMierniki parametrów sieci energetycznych","test_object_en":"Multimeters\nDigital ammeters\nAnalogue ammeters\nPower quality meters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"10 µA do 100 µA","cmc":"0,014 %"},{"name":"","range":"100 µA do 100 mA","cmc":"0,0049 %"},{"name":"","range":"100 mA do 1 A","cmc":"0,014 %"},{"name":"","range":"1 A do 10 A","cmc":"0,033 %"},{"name":"","range":"10 A do 20 A","cmc":"0,1%"}],"parameters_en":[{"name":"","range":"10 µA to 100 µA","cmc":"0,014 %"},{"name":"","range":"100 µA to 100 mA","cmc":"0,0049 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,014 %"},{"name":"","range":"1 A to 10 A","cmc":"0,033 %"},{"name":"","range":"10 A to 20 A","cmc":"0,1%"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n10 µA do 100 µA CMC 0,014 %\n100 µA do 100 mA CMC 0,0049 %\n100 mA do 1 A CMC 0,014 %\n1 A do 10 A CMC 0,033 %\n10 A do 20 A CMC 0,1%\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/02\nIW/LW3/09\nIW/LW3/18","norm_bases":["IW/LW3/02","IW/LW3/09","IW/LW3/18"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Multimetry\nMierniki prądu cyfrowe\nMierniki prądu analogowe\nMierniki parametrów sieci energetycznych Wzorcowanie — Prąd DC\nZakres:\n10 µA do 100 µA CMC 0,014 %\n100 µA do 100 mA CMC 0,0049 %\n100 mA do 1 A CMC 0,014 %\n1 A do 10 A CMC 0,033 %\n10 A do 20 A CMC 0,1%\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/02\nIW/LW3/09\nIW/LW3/18 Multimetry\nMierniki pradu cyfrowe\nMierniki pradu analogowe\nMierniki parametrow sieci energetycznych Wzorcowanie — Prad DC\nZakres:\n10 µA do 100 µA CMC 0,014 %\n100 µA do 100 mA CMC 0,0049 %\n100 mA do 1 A CMC 0,014 %\n1 A do 10 A CMC 0,033 %\n10 A do 20 A CMC 0,1%\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/02\nIW/LW3/09\nIW/LW3/18","search_en":"Multimeters Digital ammeters Analogue ammeters Power quality meters Calibration — DC current Internal procedure; Direct method; At permanent location (S) DC current Internal procedure Direct method At permanent location (S) IW/LW3/02 IW/LW3/09 IW/LW3/18","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":38,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"10 µA to 100 µA","cmc":"0,014 %"},{"name":"","range":"100 µA to 100 mA","cmc":"0,0049 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,014 %"},{"name":"","range":"1 A to 10 A","cmc":"0,033 %"},{"name":"","range":"10 A to 20 A","cmc":"0,1%"}],"regulatory_area_de":"DC-Strom","search_de":"Multimeter Digitale Strommessgeräte Analoge Strommessgeräte Netzanalysatoren für Energienetze Kalibrierung — DC-Strom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) IW/LW3/02 IW/LW3/09 IW/LW3/18","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter\nDigitale Strommessgeräte\nAnaloge Strommessgeräte\nNetzanalysatoren für Energienetze","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"10 µA to 100 µA","cmc":"0,014 %"},{"name":"","range":"100 µA to 100 mA","cmc":"0,0049 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,014 %"},{"name":"","range":"1 A to 10 A","cmc":"0,033 %"},{"name":"","range":"10 A to 20 A","cmc":"0,1%"}],"regulatory_area_zh":"直流电流","search_zh":"万用表 数字电流表 模拟电流表 电网参数测量仪 校准 — 直流电流 内部程序；直接法；在固定地点 (S) 直流电流 内部程序 直接法 在固定地点 (S) IW/LW3/02 IW/LW3/09 IW/LW3/18","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"万用表\n数字电流表\n模拟电流表\n电网参数测量仪","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"10 µA to 100 µA","cmc":"0,014 %"},{"name":"","range":"100 µA to 100 mA","cmc":"0,0049 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,014 %"},{"name":"","range":"1 A to 10 A","cmc":"0,033 %"},{"name":"","range":"10 A to 20 A","cmc":"0,1%"}],"regulatory_area_cs":"Proud DC","search_cs":"Multimetry Digitální měřiče proudu Analogové měřiče proudu Měřiče parametrů energetické sítě Kalibrace — Proud DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) IW/LW3/02 IW/LW3/09 IW/LW3/18","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry\nDigitální měřiče proudu\nAnalogové měřiče proudu\nMěřiče parametrů energetické sítě"},{"_id":"107c6207e80ff3d1feb5d9ce","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,2 A do 20 A","cmc":"0,12 %"},{"name":"","range":"20 A do 525 A","cmc":"0,35 %"},{"name":"","range":"525 A do 1000 A","cmc":"0,44 %"}],"parameters_en":[{"name":"","range":"0,2 A to 20 A","cmc":"0,12 %"},{"name":"","range":"20 A to 525 A","cmc":"0,35 %"},{"name":"","range":"525 A to 1000 A","cmc":"0,44 %"}],"technique":"Procedura wewnętrzna; Pomiar z cęgami\nMetoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Measurement with clamps\nDirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Pomiar z cęgami\nMetoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Measurement with clamps\nDirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,2 A do 20 A CMC 0,12 %\n20 A do 525 A CMC 0,35 %\n525 A do 1000 A CMC 0,44 %\nProcedura wewnętrzna; Pomiar z cęgami\nMetoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/02","norm_bases":["IW/LW3/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Mierniki cęgowe Wzorcowanie — Prąd DC\nZakres:\n0,2 A do 20 A CMC 0,12 %\n20 A do 525 A CMC 0,35 %\n525 A do 1000 A CMC 0,44 %\nProcedura wewnętrzna; Pomiar z cęgami\nMetoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/02 Mierniki cegowe Wzorcowanie — Prad DC\nZakres:\n0,2 A do 20 A CMC 0,12 %\n20 A do 525 A CMC 0,35 %\n525 A do 1000 A CMC 0,44 %\nProcedura wewnetrzna; Pomiar z cegami\nMetoda bezposrednia; W stalej lokalizacji (S) IW/LW3/02","search_en":"Clamp meters Calibration — DC current Internal procedure; Measurement with clamps Direct method; At permanent location (S) DC current Internal procedure Measurement with clamps Direct method At permanent location (S) IW/LW3/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":39,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,2 A to 20 A","cmc":"0,12 %"},{"name":"","range":"20 A to 525 A","cmc":"0,35 %"},{"name":"","range":"525 A to 1000 A","cmc":"0,44 %"}],"regulatory_area_de":"DC-Strom","search_de":"Zangenmessgeräte Kalibrierung — DC-Strom Internes Verfahren; Messung mit Stromzange Direktes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Messung mit Stromzange Direktes Verfahren Am festen Standort (S) IW/LW3/02","technique_de":"Internes Verfahren; Messung mit Stromzange\nDirektes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Messung mit Stromzange\nDirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,2 A to 20 A","cmc":"0,12 %"},{"name":"","range":"20 A to 525 A","cmc":"0,35 %"},{"name":"","range":"525 A to 1000 A","cmc":"0,44 %"}],"regulatory_area_zh":"直流电流","search_zh":"钳形表 校准 — 直流电流 内部程序; 使用钳形传感器测量 直接法；在固定地点 (S) 直流电流 内部程序 使用钳形传感器测量 直接法 在固定地点 (S) IW/LW3/02","technique_zh":"内部程序; 使用钳形传感器测量\n直接法；在固定地点 (S)","techniques_zh":["内部程序","使用钳形传感器测量\n直接法","在固定地点 (S)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,2 A to 20 A","cmc":"0,12 %"},{"name":"","range":"20 A to 525 A","cmc":"0,35 %"},{"name":"","range":"525 A to 1000 A","cmc":"0,44 %"}],"regulatory_area_cs":"Proud DC","search_cs":"Klešťové měřiče Kalibrace — Proud DC Vnitřní postup; Měření s klešťmi Přímá metoda; Ve stálé lokalitě (S) Proud DC Vnitřní postup Měření s klešťmi Přímá metoda Ve stálé lokalitě (S) IW/LW3/02","technique_cs":"Vnitřní postup; Měření s klešťmi\nPřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Měření s klešťmi\nPřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Klešťové měřiče"},{"_id":"91eb1c773b46fb21844076c3","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Kalibratory\nZasilacze","test_object_en":"Calibrators\nPower supplies","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"10 µA do 10 mA","cmc":"0,012 %"},{"name":"","range":"10 mA do 100 mA","cmc":"0,013 %"},{"name":"","range":"100 mA do 1 A","cmc":"0,027 %"},{"name":"","range":"1 A do 2 A","cmc":"0,021 %"},{"name":"","range":"2 A do 20 A","cmc":"0,046 %"}],"parameters_en":[{"name":"","range":"10 µA to 10 mA","cmc":"0,012 %"},{"name":"","range":"10 mA to 100 mA","cmc":"0,013 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,027 %"},{"name":"","range":"1 A to 2 A","cmc":"0,021 %"},{"name":"","range":"2 A to 20 A","cmc":"0,046 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n10 µA do 10 mA CMC 0,012 %\n10 mA do 100 mA CMC 0,013 %\n100 mA do 1 A CMC 0,027 %\n1 A do 2 A CMC 0,021 %\n2 A do 20 A CMC 0,046 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/01\nIW/LW3/16","norm_bases":["IW/LW3/01","IW/LW3/16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Kalibratory\nZasilacze Wzorcowanie — Prąd DC\nZakres:\n10 µA do 10 mA CMC 0,012 %\n10 mA do 100 mA CMC 0,013 %\n100 mA do 1 A CMC 0,027 %\n1 A do 2 A CMC 0,021 %\n2 A do 20 A CMC 0,046 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/01\nIW/LW3/16 Kalibratory\nZasilacze Wzorcowanie — Prad DC\nZakres:\n10 µA do 10 mA CMC 0,012 %\n10 mA do 100 mA CMC 0,013 %\n100 mA do 1 A CMC 0,027 %\n1 A do 2 A CMC 0,021 %\n2 A do 20 A CMC 0,046 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/01\nIW/LW3/16","search_en":"Calibrators Power supplies Calibration — DC current Internal procedure; Direct method; At permanent location (S) DC current Internal procedure Direct method At permanent location (S) IW/LW3/01 IW/LW3/16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":40,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"10 µA to 10 mA","cmc":"0,012 %"},{"name":"","range":"10 mA bis 100 mA","cmc":"0,013 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,027 %"},{"name":"","range":"1 A to 2 A","cmc":"0,021 %"},{"name":"","range":"2 A to 20 A","cmc":"0,046 %"}],"regulatory_area_de":"DC-Strom","search_de":"Kalibratoren Netzgeräte Kalibrierung — DC-Strom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) IW/LW3/01 IW/LW3/16","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"10 µA to 10 mA","cmc":"0,012 %"},{"name":"","range":"10 mA to 100 mA","cmc":"0,013 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,027 %"},{"name":"","range":"1 A to 2 A","cmc":"0,021 %"},{"name":"","range":"2 A to 20 A","cmc":"0,046 %"}],"regulatory_area_zh":"直流电流","search_zh":"校准器 电源 校准 — 直流电流 内部程序；直接法；在固定地点 (S) 直流电流 内部程序 直接法 在固定地点 (S) IW/LW3/01 IW/LW3/16","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"校准器\n电源","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"10 µA to 10 mA","cmc":"0,012 %"},{"name":"","range":"10 mA to 100 mA","cmc":"0,013 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,027 %"},{"name":"","range":"1 A to 2 A","cmc":"0,021 %"},{"name":"","range":"2 A to 20 A","cmc":"0,046 %"}],"regulatory_area_cs":"Proud DC","search_cs":"Kalibrátory Napájecí zdroje Kalibrace — Proud DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) IW/LW3/01 IW/LW3/16","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nNapájecí zdroje"},{"_id":"0ea048129e7b64fac9812c05","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Multimetry\nMierniki napięcia cyfrowe\nMierniki napięcia analogowe\nMierniki parametrów sieci energetycznych","test_object_en":"Multimeters\nDigital voltmeters\nAnalogue voltmeters\nPower quality meters","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"10 Hz do 33 kHz","range":"1 mV do 100 mV","cmc":"0,021 %"},{"name":"10 Hz do 33 kHz","range":"100 mV do 100 V","cmc":"0,0064 %"},{"name":"10 Hz do 33 kHz","range":"100 V do 1000 V","cmc":"0,016 %"},{"name":"30 kHz do 100 kHz","range":"1 mV do 100 mV","cmc":"0,06 %"},{"name":"30 kHz do 100 kHz","range":"100 mV do 10 V","cmc":"0,012 %"},{"name":"30 kHz do 100 kHz","range":"10 do 100 V","cmc":"0,019 %"},{"name":"30 kHz do 100 kHz","range":"100 do 750 V","cmc":"0,13 %"},{"name":"100 kHz do 330 kHz","range":"1 mV do 100 mV","cmc":"0,26 %"},{"name":"100 kHz do 330 kHz","range":"100 mV do 10 V","cmc":"0,043 %"},{"name":"100 kHz do 330 kHz","range":"10 V do 100 V","cmc":"0,15 %"},{"name":"300 kHz do 1 MHz","range":"1 V do 10 V","cmc":"0,041 %"}],"parameters_en":[{"name":"10 Hz to 33 kHz","range":"1 mV to 100 mV","cmc":"0,021 %"},{"name":"10 Hz to 33 kHz","range":"100 mV to 100 V","cmc":"0,0064 %"},{"name":"10 Hz to 33 kHz","range":"100 V to 1000 V","cmc":"0,016 %"},{"name":"30 kHz to 100 kHz","range":"1 mV to 100 mV","cmc":"0,06 %"},{"name":"30 kHz to 100 kHz","range":"100 mV to 10 V","cmc":"0,012 %"},{"name":"30 kHz to 100 kHz","range":"10 to 100 V","cmc":"0,019 %"},{"name":"30 kHz to 100 kHz","range":"100 to 750 V","cmc":"0,13 %"},{"name":"100 kHz to 330 kHz","range":"1 mV to 100 mV","cmc":"0,26 %"},{"name":"100 kHz to 330 kHz","range":"100 mV to 10 V","cmc":"0,043 %"},{"name":"100 kHz to 330 kHz","range":"10 V to 100 V","cmc":"0,15 %"},{"name":"300 kHz to 1 MHz","range":"1 V to 10 V","cmc":"0,041 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 33 kHz 1 mV do 100 mV CMC 0,021 %\n10 Hz do 33 kHz 100 mV do 100 V CMC 0,0064 %\n10 Hz do 33 kHz 100 V do 1000 V CMC 0,016 %\n30 kHz do 100 kHz 1 mV do 100 mV CMC 0,06 %\n30 kHz do 100 kHz 100 mV do 10 V CMC 0,012 %\n30 kHz do 100 kHz 10 do 100 V CMC 0,019 %\n30 kHz do 100 kHz 100 do 750 V CMC 0,13 %\n100 kHz do 330 kHz 1 mV do 100 mV CMC 0,26 %\n100 kHz do 330 kHz 100 mV do 10 V CMC 0,043 %\n100 kHz do 330 kHz 10 V do 100 V CMC 0,15 %\n300 kHz do 1 MHz 1 V do 10 V CMC 0,041 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/02\nIW/LW3/09\nIW/LW3/18","norm_bases":["IW/LW3/02","IW/LW3/09","IW/LW3/18"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Multimetry\nMierniki napięcia cyfrowe\nMierniki napięcia analogowe\nMierniki parametrów sieci energetycznych Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 33 kHz 1 mV do 100 mV CMC 0,021 %\n10 Hz do 33 kHz 100 mV do 100 V CMC 0,0064 %\n10 Hz do 33 kHz 100 V do 1000 V CMC 0,016 %\n30 kHz do 100 kHz 1 mV do 100 mV CMC 0,06 %\n30 kHz do 100 kHz 100 mV do 10 V CMC 0,012 %\n30 kHz do 100 kHz 10 do 100 V CMC 0,019 %\n30 kHz do 100 kHz 100 do 750 V CMC 0,13 %\n100 kHz do 330 kHz 1 mV do 100 mV CMC 0,26 %\n100 kHz do 330 kHz 100 mV do 10 V CMC 0,043 %\n100 kHz do 330 kHz 10 V do 100 V CMC 0,15 %\n300 kHz do 1 MHz 1 V do 10 V CMC 0,041 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/02\nIW/LW3/09\nIW/LW3/18 Multimetry\nMierniki napiecia cyfrowe\nMierniki napiecia analogowe\nMierniki parametrow sieci energetycznych Wzorcowanie — Napiecie AC\nZakres:\n10 Hz do 33 kHz 1 mV do 100 mV CMC 0,021 %\n10 Hz do 33 kHz 100 mV do 100 V CMC 0,0064 %\n10 Hz do 33 kHz 100 V do 1000 V CMC 0,016 %\n30 kHz do 100 kHz 1 mV do 100 mV CMC 0,06 %\n30 kHz do 100 kHz 100 mV do 10 V CMC 0,012 %\n30 kHz do 100 kHz 10 do 100 V CMC 0,019 %\n30 kHz do 100 kHz 100 do 750 V CMC 0,13 %\n100 kHz do 330 kHz 1 mV do 100 mV CMC 0,26 %\n100 kHz do 330 kHz 100 mV do 10 V CMC 0,043 %\n100 kHz do 330 kHz 10 V do 100 V CMC 0,15 %\n300 kHz do 1 MHz 1 V do 10 V CMC 0,041 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/02\nIW/LW3/09\nIW/LW3/18","search_en":"Multimeters Digital voltmeters Analogue voltmeters Power quality meters Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) AC voltage Internal procedure Direct method At permanent location (S) 10 Hz to 33 kHz 10 Hz to 33 kHz 10 Hz to 33 kHz 30 kHz to 100 kHz 30 kHz to 100 kHz 30 kHz to 100 kHz 30 kHz to 100 kHz 100 kHz to 330 kHz 100 kHz to 330 kHz 100 kHz to 330 kHz 300 kHz to 1 MHz IW/LW3/02 IW/LW3/09 IW/LW3/18","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":41,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"10 Hz bis 33 kHz","range":"1 mV to 100 mV","cmc":"0,021 %"},{"name":"10 Hz bis 33 kHz","range":"100 mV to 100 V","cmc":"0,0064 %"},{"name":"10 Hz bis 33 kHz","range":"100 V to 1000 V","cmc":"0,016 %"},{"name":"30 kHz bis 100 kHz","range":"1 mV to 100 mV","cmc":"0,06 %"},{"name":"30 kHz bis 100 kHz","range":"100 mV bis 10 V","cmc":"0,012 %"},{"name":"30 kHz bis 100 kHz","range":"10 to 100 V","cmc":"0,019 %"},{"name":"30 kHz bis 100 kHz","range":"100 to 750 V","cmc":"0,13 %"},{"name":"100 kHz bis 330 kHz","range":"1 mV to 100 mV","cmc":"0,26 %"},{"name":"100 kHz bis 330 kHz","range":"100 mV bis 10 V","cmc":"0,043 %"},{"name":"100 kHz bis 330 kHz","range":"10 V to 100 V","cmc":"0,15 %"},{"name":"300 kHz bis 1 MHz","range":"1 V to 10 V","cmc":"0,041 %"}],"regulatory_area_de":"AC-Spannung","search_de":"Multimeter Digitale Spannungsmessgeräte Analoge Spannungsmessgeräte Netzanalysatoren für Energienetze Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) 10 Hz bis 33 kHz 10 Hz bis 33 kHz 10 Hz bis 33 kHz 30 kHz bis 100 kHz 30 kHz bis 100 kHz 30 kHz bis 100 kHz 30 kHz bis 100 kHz 100 kHz bis 330 kHz 100 kHz bis 330 kHz 100 kHz bis 330 kHz 300 kHz bis 1 MHz IW/LW3/02 IW/LW3/09 IW/LW3/18","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter\nDigitale Spannungsmessgeräte\nAnaloge Spannungsmessgeräte\nNetzanalysatoren für Energienetze","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"10 Hz 至 33 kHz","range":"1 mV to 100 mV","cmc":"0,021 %"},{"name":"10 Hz 至 33 kHz","range":"100 mV to 100 V","cmc":"0,0064 %"},{"name":"10 Hz 至 33 kHz","range":"100 V to 1000 V","cmc":"0,016 %"},{"name":"30 kHz 至 100 kHz","range":"1 mV to 100 mV","cmc":"0,06 %"},{"name":"30 kHz 至 100 kHz","range":"100 mV to 10 V","cmc":"0,012 %"},{"name":"30 kHz 至 100 kHz","range":"10 to 100 V","cmc":"0,019 %"},{"name":"30 kHz 至 100 kHz","range":"100 to 750 V","cmc":"0,13 %"},{"name":"100 kHz 至 330 kHz","range":"1 mV to 100 mV","cmc":"0,26 %"},{"name":"100 kHz 至 330 kHz","range":"100 mV to 10 V","cmc":"0,043 %"},{"name":"100 kHz 至 330 kHz","range":"10 V to 100 V","cmc":"0,15 %"},{"name":"300 kHz 至 1 MHz","range":"1 V to 10 V","cmc":"0,041 %"}],"regulatory_area_zh":"交流电压","search_zh":"万用表 数字电压表 模拟电压表 电网参数测量仪 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 交流电压 内部程序 直接法 在固定地点 (S) 10 Hz 至 33 kHz 10 Hz 至 33 kHz 10 Hz 至 33 kHz 30 kHz 至 100 kHz 30 kHz 至 100 kHz 30 kHz 至 100 kHz 30 kHz 至 100 kHz 100 kHz 至 330 kHz 100 kHz 至 330 kHz 100 kHz 至 330 kHz 300 kHz 至 1 MHz IW/LW3/02 IW/LW3/09 IW/LW3/18","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"万用表\n数字电压表\n模拟电压表\n电网参数测量仪","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"10 Hz až 33 kHz","range":"1 mV to 100 mV","cmc":"0,021 %"},{"name":"10 Hz až 33 kHz","range":"100 mV to 100 V","cmc":"0,0064 %"},{"name":"10 Hz až 33 kHz","range":"100 V to 1000 V","cmc":"0,016 %"},{"name":"30 kHz až 100 kHz","range":"1 mV to 100 mV","cmc":"0,06 %"},{"name":"30 kHz až 100 kHz","range":"100 mV to 10 V","cmc":"0,012 %"},{"name":"30 kHz až 100 kHz","range":"10 to 100 V","cmc":"0,019 %"},{"name":"30 kHz až 100 kHz","range":"100 to 750 V","cmc":"0,13 %"},{"name":"100 kHz až 330 kHz","range":"1 mV to 100 mV","cmc":"0,26 %"},{"name":"100 kHz až 330 kHz","range":"100 mV to 10 V","cmc":"0,043 %"},{"name":"100 kHz až 330 kHz","range":"10 V to 100 V","cmc":"0,15 %"},{"name":"300 kHz až 1 MHz","range":"1 V to 10 V","cmc":"0,041 %"}],"regulatory_area_cs":"Napětí AC","search_cs":"Multimetry Digitální měřiče napětí Analogové měřiče napětí Měřiče parametrů energetické sítě Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Napětí AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) 10 Hz až 33 kHz 10 Hz až 33 kHz 10 Hz až 33 kHz 30 kHz až 100 kHz 30 kHz až 100 kHz 30 kHz až 100 kHz 30 kHz až 100 kHz 100 kHz až 330 kHz 100 kHz až 330 kHz 100 kHz až 330 kHz 300 kHz až 1 MHz IW/LW3/02 IW/LW3/09 IW/LW3/18","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry\nDigitální měřiče napětí\nAnalogové měřiče napětí\nMěřiče parametrů energetické sítě"},{"_id":"21bc065171a272bf1d580d19","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Kalibratory","test_object_en":"Calibrators","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"10 Hz do 50 Hz","range":"10 mV do 100 mV","cmc":"0,077 %"},{"name":"10 Hz do 50 Hz","range":"100 mV do 100 V","cmc":"0,021 %"},{"name":"10 Hz do 50 Hz","range":"100 V do 1000 V","cmc":"0,021 %"},{"name":"50 Hz do 10 kHz","range":"10 mV do 100 mV","cmc":"0,032 %"},{"name":"50 Hz do 10 kHz","range":"100 mV do 100 V","cmc":"0,018 %"},{"name":"50 Hz do 10 kHz","range":"100 V do 1000 V","cmc":"0,02 %"},{"name":"10 kHz do 30 kHz","range":"100 mV do 100 V","cmc":"0,034 %"},{"name":"10 kHz do 30 kHz","range":"100 V do 1000 V","cmc":"0,081 %"},{"name":"30 kHz do 100 kHz","range":"10 mV do 100 V","cmc":"0,081 %"},{"name":"100 kHz do 300 kHz","range":"100 mV do 100 V","cmc":"2,65 %"}],"parameters_en":[{"name":"10 Hz to 50 Hz","range":"10 mV to 100 mV","cmc":"0,077 %"},{"name":"10 Hz to 50 Hz","range":"100 mV to 100 V","cmc":"0,021 %"},{"name":"10 Hz to 50 Hz","range":"100 V to 1000 V","cmc":"0,021 %"},{"name":"50 Hz to 10 kHz","range":"10 mV to 100 mV","cmc":"0,032 %"},{"name":"50 Hz to 10 kHz","range":"100 mV to 100 V","cmc":"0,018 %"},{"name":"50 Hz to 10 kHz","range":"100 V to 1000 V","cmc":"0,02 %"},{"name":"10 kHz to 30 kHz","range":"100 mV to 100 V","cmc":"0,034 %"},{"name":"10 kHz to 30 kHz","range":"100 V to 1000 V","cmc":"0,081 %"},{"name":"30 kHz to 100 kHz","range":"10 mV to 100 V","cmc":"0,081 %"},{"name":"100 kHz to 300 kHz","range":"100 mV to 100 V","cmc":"2,65 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 50 Hz 10 mV do 100 mV CMC 0,077 %\n10 Hz do 50 Hz 100 mV do 100 V CMC 0,021 %\n10 Hz do 50 Hz 100 V do 1000 V CMC 0,021 %\n50 Hz do 10 kHz 10 mV do 100 mV CMC 0,032 %\n50 Hz do 10 kHz 100 mV do 100 V CMC 0,018 %\n50 Hz do 10 kHz 100 V do 1000 V CMC 0,02 %\n10 kHz do 30 kHz 100 mV do 100 V CMC 0,034 %\n10 kHz do 30 kHz 100 V do 1000 V CMC 0,081 %\n30 kHz do 100 kHz 10 mV do 100 V CMC 0,081 %\n100 kHz do 300 kHz 100 mV do 100 V CMC 2,65 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/01","norm_bases":["IW/LW3/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Kalibratory Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 50 Hz 10 mV do 100 mV CMC 0,077 %\n10 Hz do 50 Hz 100 mV do 100 V CMC 0,021 %\n10 Hz do 50 Hz 100 V do 1000 V CMC 0,021 %\n50 Hz do 10 kHz 10 mV do 100 mV CMC 0,032 %\n50 Hz do 10 kHz 100 mV do 100 V CMC 0,018 %\n50 Hz do 10 kHz 100 V do 1000 V CMC 0,02 %\n10 kHz do 30 kHz 100 mV do 100 V CMC 0,034 %\n10 kHz do 30 kHz 100 V do 1000 V CMC 0,081 %\n30 kHz do 100 kHz 10 mV do 100 V CMC 0,081 %\n100 kHz do 300 kHz 100 mV do 100 V CMC 2,65 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/01 Kalibratory Wzorcowanie — Napiecie AC\nZakres:\n10 Hz do 50 Hz 10 mV do 100 mV CMC 0,077 %\n10 Hz do 50 Hz 100 mV do 100 V CMC 0,021 %\n10 Hz do 50 Hz 100 V do 1000 V CMC 0,021 %\n50 Hz do 10 kHz 10 mV do 100 mV CMC 0,032 %\n50 Hz do 10 kHz 100 mV do 100 V CMC 0,018 %\n50 Hz do 10 kHz 100 V do 1000 V CMC 0,02 %\n10 kHz do 30 kHz 100 mV do 100 V CMC 0,034 %\n10 kHz do 30 kHz 100 V do 1000 V CMC 0,081 %\n30 kHz do 100 kHz 10 mV do 100 V CMC 0,081 %\n100 kHz do 300 kHz 100 mV do 100 V CMC 2,65 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/01","search_en":"Calibrators Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) AC voltage Internal procedure Direct method At permanent location (S) 10 Hz to 50 Hz 10 Hz to 50 Hz 10 Hz to 50 Hz 50 Hz to 10 kHz 50 Hz to 10 kHz 50 Hz to 10 kHz 10 kHz to 30 kHz 10 kHz to 30 kHz 30 kHz to 100 kHz 100 kHz to 300 kHz IW/LW3/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":42,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"10 Hz bis 50 Hz","range":"10 mV to 100 mV","cmc":"0,077 %"},{"name":"10 Hz bis 50 Hz","range":"100 mV to 100 V","cmc":"0,021 %"},{"name":"10 Hz bis 50 Hz","range":"100 V to 1000 V","cmc":"0,021 %"},{"name":"50 Hz bis 10 kHz","range":"10 mV to 100 mV","cmc":"0,032 %"},{"name":"50 Hz bis 10 kHz","range":"100 mV to 100 V","cmc":"0,018 %"},{"name":"50 Hz bis 10 kHz","range":"100 V to 1000 V","cmc":"0,02 %"},{"name":"10 kHz bis 30 kHz","range":"100 mV to 100 V","cmc":"0,034 %"},{"name":"10 kHz bis 30 kHz","range":"100 V to 1000 V","cmc":"0,081 %"},{"name":"30 kHz bis 100 kHz","range":"10 mV to 100 V","cmc":"0,081 %"},{"name":"100 kHz bis 300 kHz","range":"100 mV to 100 V","cmc":"2,65 %"}],"regulatory_area_de":"AC-Spannung","search_de":"Kalibratoren Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) 10 Hz bis 50 Hz 10 Hz bis 50 Hz 10 Hz bis 50 Hz 50 Hz bis 10 kHz 50 Hz bis 10 kHz 50 Hz bis 10 kHz 10 kHz bis 30 kHz 10 kHz bis 30 kHz 30 kHz bis 100 kHz 100 kHz bis 300 kHz IW/LW3/01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"10 Hz 至 50 Hz","range":"10 mV to 100 mV","cmc":"0,077 %"},{"name":"10 Hz 至 50 Hz","range":"100 mV to 100 V","cmc":"0,021 %"},{"name":"10 Hz 至 50 Hz","range":"100 V to 1000 V","cmc":"0,021 %"},{"name":"50 Hz 至 10 kHz","range":"10 mV to 100 mV","cmc":"0,032 %"},{"name":"50 Hz 至 10 kHz","range":"100 mV to 100 V","cmc":"0,018 %"},{"name":"50 Hz 至 10 kHz","range":"100 V to 1000 V","cmc":"0,02 %"},{"name":"10 kHz 至 30 kHz","range":"100 mV to 100 V","cmc":"0,034 %"},{"name":"10 kHz 至 30 kHz","range":"100 V to 1000 V","cmc":"0,081 %"},{"name":"30 kHz 至 100 kHz","range":"10 mV to 100 V","cmc":"0,081 %"},{"name":"100 kHz 至 300 kHz","range":"100 mV to 100 V","cmc":"2,65 %"}],"regulatory_area_zh":"交流电压","search_zh":"校准器 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 交流电压 内部程序 直接法 在固定地点 (S) 10 Hz 至 50 Hz 10 Hz 至 50 Hz 10 Hz 至 50 Hz 50 Hz 至 10 kHz 50 Hz 至 10 kHz 50 Hz 至 10 kHz 10 kHz 至 30 kHz 10 kHz 至 30 kHz 30 kHz 至 100 kHz 100 kHz 至 300 kHz IW/LW3/01","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"校准器","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"10 Hz až 50 Hz","range":"10 mV to 100 mV","cmc":"0,077 %"},{"name":"10 Hz až 50 Hz","range":"100 mV to 100 V","cmc":"0,021 %"},{"name":"10 Hz až 50 Hz","range":"100 V to 1000 V","cmc":"0,021 %"},{"name":"50 Hz až 10 kHz","range":"10 mV to 100 mV","cmc":"0,032 %"},{"name":"50 Hz až 10 kHz","range":"100 mV to 100 V","cmc":"0,018 %"},{"name":"50 Hz až 10 kHz","range":"100 V to 1000 V","cmc":"0,02 %"},{"name":"10 kHz až 30 kHz","range":"100 mV to 100 V","cmc":"0,034 %"},{"name":"10 kHz až 30 kHz","range":"100 V to 1000 V","cmc":"0,081 %"},{"name":"30 kHz až 100 kHz","range":"10 mV to 100 V","cmc":"0,081 %"},{"name":"100 kHz až 300 kHz","range":"100 mV to 100 V","cmc":"2,65 %"}],"regulatory_area_cs":"Napětí AC","search_cs":"Kalibrátory Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Napětí AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) 10 Hz až 50 Hz 10 Hz až 50 Hz 10 Hz až 50 Hz 50 Hz až 10 kHz 50 Hz až 10 kHz 50 Hz až 10 kHz 10 kHz až 30 kHz 10 kHz až 30 kHz 30 kHz až 100 kHz 100 kHz až 300 kHz IW/LW3/01","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory"},{"_id":"6995446cc1a89e95b85f2733","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Multimetry\nMierniki prądu cyfrowe\nMierniki prądu analogowe\nMierniki parametrów sieci energetycznych","test_object_en":"Multimeters\nDigital ammeters\nAnalogue ammeters\nPower quality meters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"10 Hz do 1 kHz","range":"10 µA do 100 µA","cmc":"0,038 %"},{"name":"10 Hz do 1 kHz","range":"100 µA do 100 mA","cmc":"0,022 %"},{"name":"10 Hz do 1 kHz","range":"100 mA do 1 A","cmc":"0,047 %"},{"name":"10 Hz do 1 kHz","range":"1 A do 10 A","cmc":"0,068 %"},{"name":"10 Hz do 1 kHz","range":"10 A do 20 A","cmc":"0,30 %"},{"name":"1 kHz do 5 kHz","range":"10 µA do 100 mA","cmc":"0,026 %"},{"name":"1 kHz do 5 kHz","range":"100 mA do 1 A","cmc":"0,072 %"},{"name":"1 kHz do 5 kHz","range":"1 A do 10 A","cmc":"0,17 %"},{"name":"1 kHz do 5 kHz","range":"10 A do 20 A","cmc":"0,90 %"}],"parameters_en":[{"name":"10 Hz to 1 kHz","range":"10 µA to 100 µA","cmc":"0,038 %"},{"name":"10 Hz to 1 kHz","range":"100 µA to 100 mA","cmc":"0,022 %"},{"name":"10 Hz to 1 kHz","range":"100 mA to 1 A","cmc":"0,047 %"},{"name":"10 Hz to 1 kHz","range":"1 A to 10 A","cmc":"0,068 %"},{"name":"10 Hz to 1 kHz","range":"10 A to 20 A","cmc":"0,30 %"},{"name":"1 kHz to 5 kHz","range":"10 µA to 100 mA","cmc":"0,026 %"},{"name":"1 kHz to 5 kHz","range":"100 mA to 1 A","cmc":"0,072 %"},{"name":"1 kHz to 5 kHz","range":"1 A to 10 A","cmc":"0,17 %"},{"name":"1 kHz to 5 kHz","range":"10 A to 20 A","cmc":"0,90 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 1 kHz 10 µA do 100 µA CMC 0,038 %\n10 Hz do 1 kHz 100 µA do 100 mA CMC 0,022 %\n10 Hz do 1 kHz 100 mA do 1 A CMC 0,047 %\n10 Hz do 1 kHz 1 A do 10 A CMC 0,068 %\n10 Hz do 1 kHz 10 A do 20 A CMC 0,30 %\n1 kHz do 5 kHz 10 µA do 100 mA CMC 0,026 %\n1 kHz do 5 kHz 100 mA do 1 A CMC 0,072 %\n1 kHz do 5 kHz 1 A do 10 A CMC 0,17 %\n1 kHz do 5 kHz 10 A do 20 A CMC 0,90 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/02\nIW/LW3/09\nIW/LW3/18","norm_bases":["IW/LW3/02","IW/LW3/09","IW/LW3/18"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Multimetry\nMierniki prądu cyfrowe\nMierniki prądu analogowe\nMierniki parametrów sieci energetycznych Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 1 kHz 10 µA do 100 µA CMC 0,038 %\n10 Hz do 1 kHz 100 µA do 100 mA CMC 0,022 %\n10 Hz do 1 kHz 100 mA do 1 A CMC 0,047 %\n10 Hz do 1 kHz 1 A do 10 A CMC 0,068 %\n10 Hz do 1 kHz 10 A do 20 A CMC 0,30 %\n1 kHz do 5 kHz 10 µA do 100 mA CMC 0,026 %\n1 kHz do 5 kHz 100 mA do 1 A CMC 0,072 %\n1 kHz do 5 kHz 1 A do 10 A CMC 0,17 %\n1 kHz do 5 kHz 10 A do 20 A CMC 0,90 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/02\nIW/LW3/09\nIW/LW3/18 Multimetry\nMierniki pradu cyfrowe\nMierniki pradu analogowe\nMierniki parametrow sieci energetycznych Wzorcowanie — Prad AC\nZakres:\n10 Hz do 1 kHz 10 µA do 100 µA CMC 0,038 %\n10 Hz do 1 kHz 100 µA do 100 mA CMC 0,022 %\n10 Hz do 1 kHz 100 mA do 1 A CMC 0,047 %\n10 Hz do 1 kHz 1 A do 10 A CMC 0,068 %\n10 Hz do 1 kHz 10 A do 20 A CMC 0,30 %\n1 kHz do 5 kHz 10 µA do 100 mA CMC 0,026 %\n1 kHz do 5 kHz 100 mA do 1 A CMC 0,072 %\n1 kHz do 5 kHz 1 A do 10 A CMC 0,17 %\n1 kHz do 5 kHz 10 A do 20 A CMC 0,90 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/02\nIW/LW3/09\nIW/LW3/18","search_en":"Multimeters Digital ammeters Analogue ammeters Power quality meters Calibration — AC current Internal procedure; Direct method; At permanent location (S) AC current Internal procedure Direct method At permanent location (S) 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz IW/LW3/02 IW/LW3/09 IW/LW3/18","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":43,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"10 Hz bis 1 kHz","range":"10 µA to 100 µA","cmc":"0,038 %"},{"name":"10 Hz bis 1 kHz","range":"100 µA to 100 mA","cmc":"0,022 %"},{"name":"10 Hz bis 1 kHz","range":"100 mA to 1 A","cmc":"0,047 %"},{"name":"10 Hz bis 1 kHz","range":"1 A to 10 A","cmc":"0,068 %"},{"name":"10 Hz bis 1 kHz","range":"10 A to 20 A","cmc":"0,30 %"},{"name":"1 kHz bis 5 kHz","range":"10 µA to 100 mA","cmc":"0,026 %"},{"name":"1 kHz bis 5 kHz","range":"100 mA to 1 A","cmc":"0,072 %"},{"name":"1 kHz bis 5 kHz","range":"1 A to 10 A","cmc":"0,17 %"},{"name":"1 kHz bis 5 kHz","range":"10 A to 20 A","cmc":"0,90 %"}],"regulatory_area_de":"AC-Strom","search_de":"Multimeter Digitale Strommessgeräte Analoge Strommessgeräte Netzanalysatoren für Energienetze Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) 10 Hz bis 1 kHz 10 Hz bis 1 kHz 10 Hz bis 1 kHz 10 Hz bis 1 kHz 10 Hz bis 1 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz IW/LW3/02 IW/LW3/09 IW/LW3/18","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter\nDigitale Strommessgeräte\nAnaloge Strommessgeräte\nNetzanalysatoren für Energienetze","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"10 Hz 至 1 kHz","range":"10 µA to 100 µA","cmc":"0,038 %"},{"name":"10 Hz 至 1 kHz","range":"100 µA to 100 mA","cmc":"0,022 %"},{"name":"10 Hz 至 1 kHz","range":"100 mA to 1 A","cmc":"0,047 %"},{"name":"10 Hz 至 1 kHz","range":"1 A to 10 A","cmc":"0,068 %"},{"name":"10 Hz 至 1 kHz","range":"10 A to 20 A","cmc":"0,30 %"},{"name":"1 kHz 至 5 kHz","range":"10 µA to 100 mA","cmc":"0,026 %"},{"name":"1 kHz 至 5 kHz","range":"100 mA to 1 A","cmc":"0,072 %"},{"name":"1 kHz 至 5 kHz","range":"1 A to 10 A","cmc":"0,17 %"},{"name":"1 kHz 至 5 kHz","range":"10 A to 20 A","cmc":"0,90 %"}],"regulatory_area_zh":"交流电流","search_zh":"万用表 数字电流表 模拟电流表 电网参数测量仪 校准 — 交流电流 内部程序；直接法；在固定地点 (S) 交流电流 内部程序 直接法 在固定地点 (S) 10 Hz 至 1 kHz 10 Hz 至 1 kHz 10 Hz 至 1 kHz 10 Hz 至 1 kHz 10 Hz 至 1 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz IW/LW3/02 IW/LW3/09 IW/LW3/18","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"万用表\n数字电流表\n模拟电流表\n电网参数测量仪","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"10 Hz až 1 kHz","range":"10 µA to 100 µA","cmc":"0,038 %"},{"name":"10 Hz až 1 kHz","range":"100 µA to 100 mA","cmc":"0,022 %"},{"name":"10 Hz až 1 kHz","range":"100 mA to 1 A","cmc":"0,047 %"},{"name":"10 Hz až 1 kHz","range":"1 A to 10 A","cmc":"0,068 %"},{"name":"10 Hz až 1 kHz","range":"10 A to 20 A","cmc":"0,30 %"},{"name":"1 kHz až 5 kHz","range":"10 µA to 100 mA","cmc":"0,026 %"},{"name":"1 kHz až 5 kHz","range":"100 mA to 1 A","cmc":"0,072 %"},{"name":"1 kHz až 5 kHz","range":"1 A to 10 A","cmc":"0,17 %"},{"name":"1 kHz až 5 kHz","range":"10 A to 20 A","cmc":"0,90 %"}],"regulatory_area_cs":"Proud AC","search_cs":"Multimetry Digitální měřiče proudu Analogové měřiče proudu Měřiče parametrů energetické sítě Kalibrace — Proud AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) 10 Hz až 1 kHz 10 Hz až 1 kHz 10 Hz až 1 kHz 10 Hz až 1 kHz 10 Hz až 1 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz IW/LW3/02 IW/LW3/09 IW/LW3/18","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry\nDigitální měřiče proudu\nAnalogové měřiče proudu\nMěřiče parametrů energetické sítě"},{"_id":"d951d1e84e405fc22cb28fb7","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"50 Hz","range":"0,02 A do 20 A","cmc":"0,35 %"},{"name":"50 Hz","range":"20 A do 1000 A","cmc":"0,57 %"}],"parameters_en":[{"name":"50 Hz","range":"0,02 A to 20 A","cmc":"0,35 %"},{"name":"50 Hz","range":"20 A to 1000 A","cmc":"0,57 %"}],"technique":"Procedura wewnętrzna; Pomiar z cęgami\nMetoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Measurement with clamps\nDirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Pomiar z cęgami\nMetoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Measurement with clamps\nDirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n50 Hz 0,02 A do 20 A CMC 0,35 %\n50 Hz 20 A do 1000 A CMC 0,57 %\nProcedura wewnętrzna; Pomiar z cęgami\nMetoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/02","norm_bases":["IW/LW3/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Mierniki cęgowe Wzorcowanie — Prąd AC\nZakres:\n50 Hz 0,02 A do 20 A CMC 0,35 %\n50 Hz 20 A do 1000 A CMC 0,57 %\nProcedura wewnętrzna; Pomiar z cęgami\nMetoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/02 Mierniki cegowe Wzorcowanie — Prad AC\nZakres:\n50 Hz 0,02 A do 20 A CMC 0,35 %\n50 Hz 20 A do 1000 A CMC 0,57 %\nProcedura wewnetrzna; Pomiar z cegami\nMetoda bezposrednia; W stalej lokalizacji (S) IW/LW3/02","search_en":"Clamp meters Calibration — AC current Internal procedure; Measurement with clamps Direct method; At permanent location (S) AC current Internal procedure Measurement with clamps Direct method At permanent location (S) 50 Hz 50 Hz IW/LW3/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":44,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"50 Hz","range":"0,02 A to 20 A","cmc":"0,35 %"},{"name":"50 Hz","range":"20 A to 1000 A","cmc":"0,57 %"}],"regulatory_area_de":"AC-Strom","search_de":"Zangenmessgeräte Kalibrierung — Wechselstrom Internes Verfahren; Messung mit Stromzange Direktes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Messung mit Stromzange Direktes Verfahren Am festen Standort (S) 50 Hz 50 Hz IW/LW3/02","technique_de":"Internes Verfahren; Messung mit Stromzange\nDirektes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Messung mit Stromzange\nDirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"50 Hz","range":"0,02 A to 20 A","cmc":"0,35 %"},{"name":"50 Hz","range":"20 A to 1000 A","cmc":"0,57 %"}],"regulatory_area_zh":"交流电流","search_zh":"钳形表 校准 — 交流电流 内部程序; 使用钳形传感器测量 直接法；在固定地点 (S) 交流电流 内部程序 使用钳形传感器测量 直接法 在固定地点 (S) 50 Hz 50 Hz IW/LW3/02","technique_zh":"内部程序; 使用钳形传感器测量\n直接法；在固定地点 (S)","techniques_zh":["内部程序","使用钳形传感器测量\n直接法","在固定地点 (S)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"50 Hz","range":"0,02 A to 20 A","cmc":"0,35 %"},{"name":"50 Hz","range":"20 A to 1000 A","cmc":"0,57 %"}],"regulatory_area_cs":"Proud AC","search_cs":"Klešťové měřiče Kalibrace — Proud AC Vnitřní postup; Měření s klešťmi Přímá metoda; Ve stálé lokalitě (S) Proud AC Vnitřní postup Měření s klešťmi Přímá metoda Ve stálé lokalitě (S) 50 Hz 50 Hz IW/LW3/02","technique_cs":"Vnitřní postup; Měření s klešťmi\nPřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Měření s klešťmi\nPřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Klešťové měřiče"},{"_id":"46c1c07f8dc2b450cc65994a","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Mierniki zabezpieczeń różnicowoprądowych","test_object_en":"Residual current device testers","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"50 Hz","range":"10 mA do 1000 mA","cmc":"1,3 %"}],"parameters_en":[{"name":"50 Hz","range":"10 mA to 1000 mA","cmc":"1,3 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\n50 Hz 10 mA do 1000 mA CMC 1,3 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/08","norm_bases":["IW/LW3/08"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Mierniki zabezpieczeń różnicowoprądowych Wzorcowanie — Prąd AC\n50 Hz 10 mA do 1000 mA CMC 1,3 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/08 Mierniki zabezpieczen roznicowopradowych Wzorcowanie — Prad AC\n50 Hz 10 mA do 1000 mA CMC 1,3 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/08","search_en":"Residual current device testers Calibration — AC current Internal procedure; Direct method; At permanent location (S) AC current Internal procedure Direct method At permanent location (S) 50 Hz IW/LW3/08","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":45,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"50 Hz","range":"10 mA to 1000 mA","cmc":"1,3 %"}],"regulatory_area_de":"AC-Strom","search_de":"Prüfgeräte für Fehlerstrom-Schutzeinrichtungen Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) 50 Hz IW/LW3/08","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Prüfgeräte für Fehlerstrom-Schutzeinrichtungen","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"50 Hz","range":"10 mA to 1000 mA","cmc":"1,3 %"}],"regulatory_area_zh":"交流电流","search_zh":"剩余电流保护装置测试仪 校准 — 交流电流 内部程序；直接法；在固定地点 (S) 交流电流 内部程序 直接法 在固定地点 (S) 50 Hz IW/LW3/08","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"剩余电流保护装置测试仪","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"50 Hz","range":"10 mA to 1000 mA","cmc":"1,3 %"}],"regulatory_area_cs":"Proud AC","search_cs":"Měřiče proudových chráničů Kalibrace — Proud AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) 50 Hz IW/LW3/08","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče proudových chráničů"},{"_id":"806c98633c6acf6a40f7fba4","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Kalibratory","test_object_en":"Calibrators","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"10 Hz do 5 kHz","range":"10 µA do 100 mA","cmc":"0,062 %"},{"name":"10 Hz do 5 kHz","range":"100 mA do 1 A","cmc":"0,047 %"},{"name":"10 Hz do 5 kHz","range":"1 A do 2 A","cmc":"0,084 %"},{"name":"10 Hz do 2 kHz","range":"2 A do 20 A","cmc":"0,12 %"},{"name":"2 kHz do 5 kHz","range":"2 A do 20 A","cmc":"0,32 %"}],"parameters_en":[{"name":"10 Hz to 5 kHz","range":"10 µA to 100 mA","cmc":"0,062 %"},{"name":"10 Hz to 5 kHz","range":"100 mA to 1 A","cmc":"0,047 %"},{"name":"10 Hz to 5 kHz","range":"1 A to 2 A","cmc":"0,084 %"},{"name":"10 Hz to 2 kHz","range":"2 A to 20 A","cmc":"0,12 %"},{"name":"2 kHz to 5 kHz","range":"2 A to 20 A","cmc":"0,32 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia / pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct / indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia / pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct / indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 5 kHz 10 µA do 100 mA CMC 0,062 %\n10 Hz do 5 kHz 100 mA do 1 A CMC 0,047 %\n10 Hz do 5 kHz 1 A do 2 A CMC 0,084 %\n10 Hz do 2 kHz 2 A do 20 A CMC 0,12 %\n2 kHz do 5 kHz 2 A do 20 A CMC 0,32 %\nProcedura wewnętrzna; Metoda bezpośrednia / pośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/01","norm_bases":["IW/LW3/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Kalibratory Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 5 kHz 10 µA do 100 mA CMC 0,062 %\n10 Hz do 5 kHz 100 mA do 1 A CMC 0,047 %\n10 Hz do 5 kHz 1 A do 2 A CMC 0,084 %\n10 Hz do 2 kHz 2 A do 20 A CMC 0,12 %\n2 kHz do 5 kHz 2 A do 20 A CMC 0,32 %\nProcedura wewnętrzna; Metoda bezpośrednia / pośrednia; W stałej lokalizacji (S) IW/LW3/01 Kalibratory Wzorcowanie — Prad AC\nZakres:\n10 Hz do 5 kHz 10 µA do 100 mA CMC 0,062 %\n10 Hz do 5 kHz 100 mA do 1 A CMC 0,047 %\n10 Hz do 5 kHz 1 A do 2 A CMC 0,084 %\n10 Hz do 2 kHz 2 A do 20 A CMC 0,12 %\n2 kHz do 5 kHz 2 A do 20 A CMC 0,32 %\nProcedura wewnetrzna; Metoda bezposrednia / posrednia; W stalej lokalizacji (S) IW/LW3/01","search_en":"Calibrators Calibration — AC current Internal procedure; Direct / indirect method; At permanent location (S) AC current Internal procedure Direct / indirect method At permanent location (S) 10 Hz to 5 kHz 10 Hz to 5 kHz 10 Hz to 5 kHz 10 Hz to 2 kHz 2 kHz to 5 kHz IW/LW3/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":46,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"10 Hz bis 5 kHz","range":"10 µA to 100 mA","cmc":"0,062 %"},{"name":"10 Hz bis 5 kHz","range":"100 mA to 1 A","cmc":"0,047 %"},{"name":"10 Hz bis 5 kHz","range":"1 A to 2 A","cmc":"0,084 %"},{"name":"10 Hz bis 2 kHz","range":"2 A to 20 A","cmc":"0,12 %"},{"name":"2 kHz bis 5 kHz","range":"2 A to 20 A","cmc":"0,32 %"}],"regulatory_area_de":"AC-Strom","search_de":"Kalibratoren Kalibrierung — Wechselstrom Internes Verfahren; Direktes / indirektes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Direktes / indirektes Verfahren Am festen Standort (S) 10 Hz bis 5 kHz 10 Hz bis 5 kHz 10 Hz bis 5 kHz 10 Hz bis 2 kHz 2 kHz bis 5 kHz IW/LW3/01","technique_de":"Internes Verfahren; Direktes / indirektes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes / indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"10 Hz 至 5 kHz","range":"10 µA to 100 mA","cmc":"0,062 %"},{"name":"10 Hz 至 5 kHz","range":"100 mA to 1 A","cmc":"0,047 %"},{"name":"10 Hz 至 5 kHz","range":"1 A to 2 A","cmc":"0,084 %"},{"name":"10 Hz 至 2 kHz","range":"2 A to 20 A","cmc":"0,12 %"},{"name":"2 kHz 至 5 kHz","range":"2 A to 20 A","cmc":"0,32 %"}],"regulatory_area_zh":"交流电流","search_zh":"校准器 校准 — 交流电流 内部程序；直接/间接法；在固定地点 (S) 交流电流 内部程序 直接/间接法 在固定地点 (S) 10 Hz 至 5 kHz 10 Hz 至 5 kHz 10 Hz 至 5 kHz 10 Hz 至 2 kHz 2 kHz 至 5 kHz IW/LW3/01","technique_zh":"内部程序；直接/间接法；在固定地点 (S)","techniques_zh":["内部程序","直接/间接法","在固定地点 (S)"],"test_object_zh":"校准器","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"10 Hz až 5 kHz","range":"10 µA to 100 mA","cmc":"0,062 %"},{"name":"10 Hz až 5 kHz","range":"100 mA to 1 A","cmc":"0,047 %"},{"name":"10 Hz až 5 kHz","range":"1 A to 2 A","cmc":"0,084 %"},{"name":"10 Hz až 2 kHz","range":"2 A to 20 A","cmc":"0,12 %"},{"name":"2 kHz až 5 kHz","range":"2 A to 20 A","cmc":"0,32 %"}],"regulatory_area_cs":"Proud AC","search_cs":"Kalibrátory Kalibrace — Proud AC Vnitřní postup; Přímá / nepřímá metoda; Ve stálé lokalitě (S) Proud AC Vnitřní postup Přímá / nepřímá metoda Ve stálé lokalitě (S) 10 Hz až 5 kHz 10 Hz až 5 kHz 10 Hz až 5 kHz 10 Hz až 2 kHz 2 kHz až 5 kHz IW/LW3/01","technique_cs":"Vnitřní postup; Přímá / nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá / nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory"},{"_id":"f8d8be77ac538f11a0863894","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Multimetry\nMierniki rezystancji cyfrowe","test_object_en":"Multimeters\nDigital ohmmeters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0Ω","cmc":"23 µΩ"},{"name":"","range":"30 µΩ","cmc":"2,5 %"},{"name":"","range":"0,0001 Ω do 0,01 Ω","cmc":"1%"},{"name":"","range":"0,01 Ω do 1 Ω","cmc":"0,12 ∙ 10⁻³ ∙ R + 0,023 mΩ"},{"name":"","range":"1 Ω do 10 Ω","cmc":"0,0029 %"},{"name":"","range":"10 Ω do 100 Ω","cmc":"0,0013 %"},{"name":"","range":"100 Ω do 10 kΩ","cmc":"0,0011 %"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"0,0014 %"},{"name":"","range":"100 kΩ do 1 MΩ","cmc":"0,0032 %"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"0,006 %"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"0,021 %"}],"parameters_en":[{"name":"","range":"0Ω","cmc":"23 µΩ"},{"name":"","range":"30 µΩ","cmc":"2,5 %"},{"name":"","range":"0,0001 Ω to 0,01 Ω","cmc":"1%"},{"name":"","range":"0,01 Ω to 1 Ω","cmc":"0,12 ∙ 10⁻³ ∙ R + 0,023 mΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0029 %"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0013 %"},{"name":"","range":"100 Ω to 10 kΩ","cmc":"0,0011 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0014 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,0032 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,006 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,021 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0Ω CMC 23 µΩ\n30 µΩ CMC 2,5 %\n0,0001 Ω do 0,01 Ω CMC 1%\n0,01 Ω do 1 Ω CMC 0,12 ∙ 10⁻³ ∙ R + 0,023 mΩ\n1 Ω do 10 Ω CMC 0,0029 %\n10 Ω do 100 Ω CMC 0,0013 %\n100 Ω do 10 kΩ CMC 0,0011 %\n10 kΩ do 100 kΩ CMC 0,0014 %\n100 kΩ do 1 MΩ CMC 0,0032 %\n1 MΩ do 10 MΩ CMC 0,006 %\n10 MΩ do 100 MΩ CMC 0,021 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/02","norm_bases":["IW/LW3/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. R – wielkość mierzona (Ω)","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. R – measured value (Ω)","search_text":"Multimetry\nMierniki rezystancji cyfrowe Wzorcowanie — Rezystancja DC\nZakres:\n0Ω CMC 23 µΩ\n30 µΩ CMC 2,5 %\n0,0001 Ω do 0,01 Ω CMC 1%\n0,01 Ω do 1 Ω CMC 0,12 ∙ 10⁻³ ∙ R + 0,023 mΩ\n1 Ω do 10 Ω CMC 0,0029 %\n10 Ω do 100 Ω CMC 0,0013 %\n100 Ω do 10 kΩ CMC 0,0011 %\n10 kΩ do 100 kΩ CMC 0,0014 %\n100 kΩ do 1 MΩ CMC 0,0032 %\n1 MΩ do 10 MΩ CMC 0,006 %\n10 MΩ do 100 MΩ CMC 0,021 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/02 Multimetry\nMierniki rezystancji cyfrowe Wzorcowanie — Rezystancja DC\nZakres:\n0Ω CMC 23 µΩ\n30 µΩ CMC 2,5 %\n0,0001 Ω do 0,01 Ω CMC 1%\n0,01 Ω do 1 Ω CMC 0,12 ∙ 10⁻³ ∙ R + 0,023 mΩ\n1 Ω do 10 Ω CMC 0,0029 %\n10 Ω do 100 Ω CMC 0,0013 %\n100 Ω do 10 kΩ CMC 0,0011 %\n10 kΩ do 100 kΩ CMC 0,0014 %\n100 kΩ do 1 MΩ CMC 0,0032 %\n1 MΩ do 10 MΩ CMC 0,006 %\n10 MΩ do 100 MΩ CMC 0,021 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/02","search_en":"Multimeters Digital ohmmeters Calibration — DC resistance Internal procedure; Direct method; At permanent location (S) DC resistance Internal procedure Direct method At permanent location (S) IW/LW3/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":47,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0Ω","cmc":"23 µΩ"},{"name":"","range":"30 µΩ","cmc":"2,5 %"},{"name":"","range":"0,0001 Ω to 0,01 Ω","cmc":"1%"},{"name":"","range":"0,01 Ω to 1 Ω","cmc":"0,12 ∙ 10⁻³ ∙ R + 0,023 mΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0029 %"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0013 %"},{"name":"","range":"100 Ω to 10 kΩ","cmc":"0,0011 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0014 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,0032 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,006 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,021 %"}],"regulatory_area_de":"DC-Widerstand","search_de":"Multimeter Digitale Widerstandsmessgeräte Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Direktes Verfahren Am festen Standort (S) IW/LW3/02","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter\nDigitale Widerstandsmessgeräte","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0Ω","cmc":"23 µΩ"},{"name":"","range":"30 µΩ","cmc":"2,5 %"},{"name":"","range":"0,0001 Ω to 0,01 Ω","cmc":"1%"},{"name":"","range":"0,01 Ω to 1 Ω","cmc":"0,12 ∙ 10⁻³ ∙ R + 0,023 mΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0029 %"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0013 %"},{"name":"","range":"100 Ω to 10 kΩ","cmc":"0,0011 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0014 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,0032 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,006 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,021 %"}],"regulatory_area_zh":"直流电阻","search_zh":"万用表 数字电阻测量仪 校准 — 直流电阻 内部程序；直接法；在固定地点 (S) 直流电阻 内部程序 直接法 在固定地点 (S) IW/LW3/02","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"万用表\n数字电阻测量仪","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0Ω","cmc":"23 µΩ"},{"name":"","range":"30 µΩ","cmc":"2,5 %"},{"name":"","range":"0,0001 Ω to 0,01 Ω","cmc":"1%"},{"name":"","range":"0,01 Ω to 1 Ω","cmc":"0,12 ∙ 10⁻³ ∙ R + 0,023 mΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0029 %"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0013 %"},{"name":"","range":"100 Ω to 10 kΩ","cmc":"0,0011 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0014 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,0032 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,006 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,021 %"}],"regulatory_area_cs":"Odpor DC","search_cs":"Multimetry Digitální měřiče odporu Kalibrace — Odpor DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) IW/LW3/02","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry\nDigitální měřiče odporu"},{"_id":"9ac8a6f9f032c336830edd21","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Mierniki parametrów sieci:\nMierniki rezystancji izolacji\nMierniki ciągłości obwodu","test_object_en":"Power network parameter meters:\nInsulation resistance meters\nContinuity testers","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"10 kΩ do 10 GΩ","cmc":"0,13 %"},{"name":"","range":"10 GΩ do 100 GΩ","cmc":"1,2 %"},{"name":"","range":"0,05 Ω do 10 Ω","cmc":"0,9 ∙ 10⁻³ ∙ R + 0,001 Ω"},{"name":"","range":"10 Ω do 1 kΩ","cmc":"0,9 ∙ 10⁻³ ∙ R + 0,01 Ω"}],"parameters_en":[{"name":"","range":"10 kΩ to 10 GΩ","cmc":"0,13 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"1,2 %"},{"name":"","range":"0,05 Ω to 10 Ω","cmc":"0,9 ∙ 10⁻³ ∙ R + 0,001 Ω"},{"name":"","range":"10 Ω to 1 kΩ","cmc":"0,9 ∙ 10⁻³ ∙ R + 0,01 Ω"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n10 kΩ do 10 GΩ CMC 0,13 %\n10 GΩ do 100 GΩ CMC 1,2 %\n0,05 Ω do 10 Ω CMC 0,9 ∙ 10⁻³ ∙ R + 0,001 Ω\n10 Ω do 1 kΩ CMC 0,9 ∙ 10⁻³ ∙ R + 0,01 Ω\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/05\nIW/LW3/06\nIW/LW3/09","norm_bases":["IW/LW3/05","IW/LW3/06","IW/LW3/09"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. R – wielkość mierzona (Ω)","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. R – measured value (Ω)","search_text":"Mierniki parametrów sieci:\nMierniki rezystancji izolacji\nMierniki ciągłości obwodu Wzorcowanie — Rezystancja DC\nZakres:\n10 kΩ do 10 GΩ CMC 0,13 %\n10 GΩ do 100 GΩ CMC 1,2 %\n0,05 Ω do 10 Ω CMC 0,9 ∙ 10⁻³ ∙ R + 0,001 Ω\n10 Ω do 1 kΩ CMC 0,9 ∙ 10⁻³ ∙ R + 0,01 Ω\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/05\nIW/LW3/06\nIW/LW3/09 Mierniki parametrow sieci:\nMierniki rezystancji izolacji\nMierniki ciaglosci obwodu Wzorcowanie — Rezystancja DC\nZakres:\n10 kΩ do 10 GΩ CMC 0,13 %\n10 GΩ do 100 GΩ CMC 1,2 %\n0,05 Ω do 10 Ω CMC 0,9 ∙ 10⁻³ ∙ R + 0,001 Ω\n10 Ω do 1 kΩ CMC 0,9 ∙ 10⁻³ ∙ R + 0,01 Ω\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/05\nIW/LW3/06\nIW/LW3/09","search_en":"Power network parameter meters: Insulation resistance meters Continuity testers Calibration — DC resistance Internal procedure; Direct method; At permanent location (S) DC resistance Internal procedure Direct method At permanent location (S) IW/LW3/05 IW/LW3/06 IW/LW3/09","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":48,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"10 kΩ to 10 GΩ","cmc":"0,13 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"1,2 %"},{"name":"","range":"0,05 Ω to 10 Ω","cmc":"0,9 ∙ 10⁻³ ∙ R + 0,001 Ω"},{"name":"","range":"10 Ω to 1 kΩ","cmc":"0,9 ∙ 10⁻³ ∙ R + 0,01 Ω"}],"regulatory_area_de":"DC-Widerstand","search_de":"Netzparametermessgeräte: Isolationswiderstandsmessgeräte Durchgangsprüfer Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Direktes Verfahren Am festen Standort (S) IW/LW3/05 IW/LW3/06 IW/LW3/09","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Netzparametermessgeräte:\nIsolationswiderstandsmessgeräte\nDurchgangsprüfer","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"10 kΩ to 10 GΩ","cmc":"0,13 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"1,2 %"},{"name":"","range":"0,05 Ω to 10 Ω","cmc":"0,9 ∙ 10⁻³ ∙ R + 0,001 Ω"},{"name":"","range":"10 Ω to 1 kΩ","cmc":"0,9 ∙ 10⁻³ ∙ R + 0,01 Ω"}],"regulatory_area_zh":"直流电阻","search_zh":"电网参数测量仪： 绝缘电阻测量仪 电路通断测试仪 校准 — 直流电阻 内部程序；直接法；在固定地点 (S) 直流电阻 内部程序 直接法 在固定地点 (S) IW/LW3/05 IW/LW3/06 IW/LW3/09","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"电网参数测量仪：\n绝缘电阻测量仪\n电路通断测试仪","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"10 kΩ to 10 GΩ","cmc":"0,13 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"1,2 %"},{"name":"","range":"0,05 Ω to 10 Ω","cmc":"0,9 ∙ 10⁻³ ∙ R + 0,001 Ω"},{"name":"","range":"10 Ω to 1 kΩ","cmc":"0,9 ∙ 10⁻³ ∙ R + 0,01 Ω"}],"regulatory_area_cs":"Odpor DC","search_cs":"Měřiče parametrů sítě: Měřiče izolačního odporu Měřiče spojitosti obvodu Kalibrace — Odpor DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) IW/LW3/05 IW/LW3/06 IW/LW3/09","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče parametrů sítě:\nMěřiče izolačního odporu\nMěřiče spojitosti obvodu"},{"_id":"cec16d644d06ecf8594c1368","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Kalibratory rezystancji\nRezystory regulowane","test_object_en":"Resistance calibrators\nVariable resistors","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0,01 Ω do 0,1 Ω","cmc":"1,4 ∙ 10⁻³ ∙ R + 0,014 Ω"},{"name":"","range":"0,1 Ω do 1 Ω","cmc":"0,015 %"},{"name":"","range":"1 Ω do 10 Ω","cmc":"0,0020 %"},{"name":"","range":"10 Ω do 100 Ω","cmc":"0,0014 %"},{"name":"","range":"100 Ω do 100 kΩ","cmc":"0,0011 %"},{"name":"","range":"100 kΩ do 1 MΩ","cmc":"0,0017 %"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"0,0045 %"},{"name":"","range":"10 MΩ do 1 GΩ","cmc":"0,045 %"}],"parameters_en":[{"name":"","range":"0,01 Ω to 0,1 Ω","cmc":"1,4 ∙ 10⁻³ ∙ R + 0,014 Ω"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"0,015 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0020 %"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0014 %"},{"name":"","range":"100 Ω to 100 kΩ","cmc":"0,0011 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,0017 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,0045 %"},{"name":"","range":"10 MΩ to 1 GΩ","cmc":"0,045 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0,01 Ω do 0,1 Ω CMC 1,4 ∙ 10⁻³ ∙ R + 0,014 Ω\n0,1 Ω do 1 Ω CMC 0,015 %\n1 Ω do 10 Ω CMC 0,0020 %\n10 Ω do 100 Ω CMC 0,0014 %\n100 Ω do 100 kΩ CMC 0,0011 %\n100 kΩ do 1 MΩ CMC 0,0017 %\n1 MΩ do 10 MΩ CMC 0,0045 %\n10 MΩ do 1 GΩ CMC 0,045 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/01\nIW/LW3/15","norm_bases":["IW/LW3/01","IW/LW3/15"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. R – wielkość mierzona (Ω)","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. R – measured value (Ω)","search_text":"Kalibratory rezystancji\nRezystory regulowane Wzorcowanie — Rezystancja DC\nZakres:\n0,01 Ω do 0,1 Ω CMC 1,4 ∙ 10⁻³ ∙ R + 0,014 Ω\n0,1 Ω do 1 Ω CMC 0,015 %\n1 Ω do 10 Ω CMC 0,0020 %\n10 Ω do 100 Ω CMC 0,0014 %\n100 Ω do 100 kΩ CMC 0,0011 %\n100 kΩ do 1 MΩ CMC 0,0017 %\n1 MΩ do 10 MΩ CMC 0,0045 %\n10 MΩ do 1 GΩ CMC 0,045 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/01\nIW/LW3/15 Kalibratory rezystancji\nRezystory regulowane Wzorcowanie — Rezystancja DC\nZakres:\n0,01 Ω do 0,1 Ω CMC 1,4 ∙ 10⁻³ ∙ R + 0,014 Ω\n0,1 Ω do 1 Ω CMC 0,015 %\n1 Ω do 10 Ω CMC 0,0020 %\n10 Ω do 100 Ω CMC 0,0014 %\n100 Ω do 100 kΩ CMC 0,0011 %\n100 kΩ do 1 MΩ CMC 0,0017 %\n1 MΩ do 10 MΩ CMC 0,0045 %\n10 MΩ do 1 GΩ CMC 0,045 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/01\nIW/LW3/15","search_en":"Resistance calibrators Variable resistors Calibration — DC resistance Internal procedure; Direct method; At permanent location (S) DC resistance Internal procedure Direct method At permanent location (S) IW/LW3/01 IW/LW3/15","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":49,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0,01 Ω to 0,1 Ω","cmc":"1,4 ∙ 10⁻³ ∙ R + 0,014 Ω"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"0,015 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0020 %"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0014 %"},{"name":"","range":"100 Ω to 100 kΩ","cmc":"0,0011 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,0017 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,0045 %"},{"name":"","range":"10 MΩ to 1 GΩ","cmc":"0,045 %"}],"regulatory_area_de":"DC-Widerstand","search_de":"Widerstandskalibratoren Einstellbare Widerstände Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Direktes Verfahren Am festen Standort (S) IW/LW3/01 IW/LW3/15","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Widerstandskalibratoren\nEinstellbare Widerstände","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0,01 Ω to 0,1 Ω","cmc":"1,4 ∙ 10⁻³ ∙ R + 0,014 Ω"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"0,015 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0020 %"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0014 %"},{"name":"","range":"100 Ω to 100 kΩ","cmc":"0,0011 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,0017 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,0045 %"},{"name":"","range":"10 MΩ to 1 GΩ","cmc":"0,045 %"}],"regulatory_area_zh":"直流电阻","search_zh":"电阻校准器 可调电阻器 校准 — 直流电阻 内部程序；直接法；在固定地点 (S) 直流电阻 内部程序 直接法 在固定地点 (S) IW/LW3/01 IW/LW3/15","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"电阻校准器\n可调电阻器","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0,01 Ω to 0,1 Ω","cmc":"1,4 ∙ 10⁻³ ∙ R + 0,014 Ω"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"0,015 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0020 %"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0014 %"},{"name":"","range":"100 Ω to 100 kΩ","cmc":"0,0011 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,0017 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,0045 %"},{"name":"","range":"10 MΩ to 1 GΩ","cmc":"0,045 %"}],"regulatory_area_cs":"Odpor DC","search_cs":"Kalibrátory odporu Nastavitelné rezistory Kalibrace — Odpor DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) IW/LW3/01 IW/LW3/15","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory odporu\nNastavitelné rezistory"},{"_id":"2965f5c07a36dcafc72de6a5","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Mierniki parametrów sieci:\nMierniki rezystancji pętli zwarcia\nMierniki rezystancji uziemienia","test_object_en":"Power network parameter meters:\nLoop impedance meters\nEarth resistance meters","methodology":"Wzorcowanie — Rezystancja AC","methodology_en":"Calibration — AC resistance","parameters":[{"name":"","range":"0,30 Ω do 1000 Ω","cmc":"5,8 ∙ 10⁻³ ∙ R + 0,01 Ω"},{"name":"","range":"0,3 Ω do 20 kΩ","cmc":"1,0 ∙ 10⁻³ ∙ R + 0,01 Ω"}],"parameters_en":[{"name":"","range":"0,30 Ω to 1000 Ω","cmc":"5,8 ∙ 10⁻³ ∙ R + 0,01 Ω"},{"name":"","range":"0,3 Ω to 20 kΩ","cmc":"1,0 ∙ 10⁻³ ∙ R + 0,01 Ω"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja AC\nZakres:\n0,30 Ω do 1000 Ω CMC 5,8 ∙ 10⁻³ ∙ R + 0,01 Ω\n0,3 Ω do 20 kΩ CMC 1,0 ∙ 10⁻³ ∙ R + 0,01 Ω\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/06\nIW/LW3/07","norm_bases":["IW/LW3/06","IW/LW3/07"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja AC","regulatory_area_en":"AC resistance","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. R – wielkość mierzona (Ω)","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. R – measured value (Ω)","search_text":"Mierniki parametrów sieci:\nMierniki rezystancji pętli zwarcia\nMierniki rezystancji uziemienia Wzorcowanie — Rezystancja AC\nZakres:\n0,30 Ω do 1000 Ω CMC 5,8 ∙ 10⁻³ ∙ R + 0,01 Ω\n0,3 Ω do 20 kΩ CMC 1,0 ∙ 10⁻³ ∙ R + 0,01 Ω\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/06\nIW/LW3/07 Mierniki parametrow sieci:\nMierniki rezystancji petli zwarcia\nMierniki rezystancji uziemienia Wzorcowanie — Rezystancja AC\nZakres:\n0,30 Ω do 1000 Ω CMC 5,8 ∙ 10⁻³ ∙ R + 0,01 Ω\n0,3 Ω do 20 kΩ CMC 1,0 ∙ 10⁻³ ∙ R + 0,01 Ω\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/06\nIW/LW3/07","search_en":"Power network parameter meters: Loop impedance meters Earth resistance meters Calibration — AC resistance Internal procedure; Direct method; At permanent location (S) AC resistance Internal procedure Direct method At permanent location (S) IW/LW3/06 IW/LW3/07","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":50,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstromwiderstand","parameters_de":[{"name":"","range":"0,30 Ω to 1000 Ω","cmc":"5,8 ∙ 10⁻³ ∙ R + 0,01 Ω"},{"name":"","range":"0,3 Ω to 20 kΩ","cmc":"1,0 ∙ 10⁻³ ∙ R + 0,01 Ω"}],"regulatory_area_de":"AC-Widerstand","search_de":"Netzparametermessgeräte: Schleifenimpedanz-Messgeräte Erdungswiderstandsmessgeräte Kalibrierung — Wechselstromwiderstand Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Widerstand Internes Verfahren Direktes Verfahren Am festen Standort (S) IW/LW3/06 IW/LW3/07","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Netzparametermessgeräte:\nSchleifenimpedanz-Messgeräte\nErdungswiderstandsmessgeräte","methodology_zh":"校准 — 交流电阻","parameters_zh":[{"name":"","range":"0,30 Ω to 1000 Ω","cmc":"5,8 ∙ 10⁻³ ∙ R + 0,01 Ω"},{"name":"","range":"0,3 Ω to 20 kΩ","cmc":"1,0 ∙ 10⁻³ ∙ R + 0,01 Ω"}],"regulatory_area_zh":"交流电阻","search_zh":"电网参数测量仪： 故障回路阻抗测量仪 接地电阻测量仪 校准 — 交流电阻 内部程序；直接法；在固定地点 (S) 交流电阻 内部程序 直接法 在固定地点 (S) IW/LW3/06 IW/LW3/07","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"电网参数测量仪：\n故障回路阻抗测量仪\n接地电阻测量仪","methodology_cs":"Kalibrace — Odpor AC","parameters_cs":[{"name":"","range":"0,30 Ω to 1000 Ω","cmc":"5,8 ∙ 10⁻³ ∙ R + 0,01 Ω"},{"name":"","range":"0,3 Ω to 20 kΩ","cmc":"1,0 ∙ 10⁻³ ∙ R + 0,01 Ω"}],"regulatory_area_cs":"Odpor AC","search_cs":"Měřiče parametrů sítě: Měřiče impedance smyčky Měřiče zemního odporu Kalibrace — Odpor AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Odpor AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) IW/LW3/06 IW/LW3/07","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče parametrů sítě:\nMěřiče impedance smyčky\nMěřiče zemního odporu"},{"_id":"6bcd71f1031a94b92b0a9fc3","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Mierniki zabezpieczeń różnicowoprądowych","test_object_en":"Residual current device testers","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"20 ms do 200 ms","cmc":"1,1 ms"},{"name":"","range":"210 ms do 400 ms","cmc":"1,2 ms"},{"name":"","range":"410 ms do 1 s","cmc":"8,2 ms"}],"parameters_en":[{"name":"","range":"20 ms to 200 ms","cmc":"1,1 ms"},{"name":"","range":"210 ms to 400 ms","cmc":"1,2 ms"},{"name":"","range":"410 ms to 1 s","cmc":"8,2 ms"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\n20 ms do 200 ms CMC 1,1 ms\n210 ms do 400 ms CMC 1,2 ms\n410 ms do 1 s CMC 8,2 ms\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/08","norm_bases":["IW/LW3/08"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Mierniki zabezpieczeń różnicowoprądowych Wzorcowanie — Czas (przedział czasu)\nZakres:\n20 ms do 200 ms CMC 1,1 ms\n210 ms do 400 ms CMC 1,2 ms\n410 ms do 1 s CMC 8,2 ms\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/08 Mierniki zabezpieczen roznicowopradowych Wzorcowanie — Czas (przedzial czasu)\nZakres:\n20 ms do 200 ms CMC 1,1 ms\n210 ms do 400 ms CMC 1,2 ms\n410 ms do 1 s CMC 8,2 ms\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/08","search_en":"Residual current device testers Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) IW/LW3/08","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":51,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"20 ms to 200 ms","cmc":"1,1 ms"},{"name":"","range":"210 ms to 400 ms","cmc":"1,2 ms"},{"name":"","range":"410 ms to 1 s","cmc":"8,2 ms"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Prüfgeräte für Fehlerstrom-Schutzeinrichtungen Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) IW/LW3/08","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Prüfgeräte für Fehlerstrom-Schutzeinrichtungen","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"20 ms to 200 ms","cmc":"1,1 ms"},{"name":"","range":"210 ms to 400 ms","cmc":"1,2 ms"},{"name":"","range":"410 ms to 1 s","cmc":"8,2 ms"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"剩余电流保护装置测试仪 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) IW/LW3/08","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"剩余电流保护装置测试仪","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"20 ms to 200 ms","cmc":"1,1 ms"},{"name":"","range":"210 ms to 400 ms","cmc":"1,2 ms"},{"name":"","range":"410 ms to 1 s","cmc":"8,2 ms"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Měřiče proudových chráničů Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) IW/LW3/08","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče proudových chráničů"},{"_id":"314ddbba8f75cc88e9c8f945","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Sekundomierze (stopery) elektroniczne\nSekundomierze elektroniczne\n(dawkowniki czasu)","test_object_en":"Electronic stopwatches\nElectronic timers\n(time dispensers)","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"0 h do 24 h","cmc":"0,02 s + 2,8 · 10⁻⁷ · τ"}],"parameters_en":[{"name":"","range":"0 h to 24 h","cmc":"0,02 s + 2,8 · 10⁻⁷ · τ"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\n0 h do 24 h CMC 0,02 s + 2,8 · 10⁻⁷ · τ\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/13","norm_bases":["IW/LW3/13"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. τ - wartość mierzona (s)","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. τ - measured value (s)","search_text":"Sekundomierze (stopery) elektroniczne\nSekundomierze elektroniczne\n(dawkowniki czasu) Wzorcowanie — Czas (przedział czasu)\n0 h do 24 h CMC 0,02 s + 2,8 · 10⁻⁷ · τ\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/13 Sekundomierze (stopery) elektroniczne\nSekundomierze elektroniczne\n(dawkowniki czasu) Wzorcowanie — Czas (przedzial czasu)\n0 h do 24 h CMC 0,02 s + 2,8 · 10⁻⁷ · τ\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/13","search_en":"Electronic stopwatches Electronic timers (time dispensers) Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) IW/LW3/13","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":52,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"0 h to 24 h","cmc":"0,02 s + 2,8 · 10⁻⁷ · τ"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Elektronische Stoppuhren Elektronische Stoppuhren (Zeitdosierer) Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) IW/LW3/13","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Elektronische Stoppuhren\nElektronische Stoppuhren\n(Zeitdosierer)","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"0 h to 24 h","cmc":"0,02 s + 2,8 · 10⁻⁷ · τ"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"电子秒表 电子秒表 （定时器） 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) IW/LW3/13","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"电子秒表\n电子秒表\n（定时器）","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"0 h to 24 h","cmc":"0,02 s + 2,8 · 10⁻⁷ · τ"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Elektronické stopky Elektronické stopky (časovače) Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) IW/LW3/13","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Elektronické stopky\nElektronické stopky\n(časovače)"},{"_id":"0e051df92c5d572dea29c1e3","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Sekundomierze (stopery) mechaniczne","test_object_en":"Mechanical stopwatches","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"0 h do 1 h","cmc":"0,07 s + 1,2 · 10⁻⁵ · τ"}],"parameters_en":[{"name":"","range":"0 h to 1 h","cmc":"0,07 s + 1,2 · 10⁻⁵ · τ"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\n0 h do 1 h CMC 0,07 s + 1,2 · 10⁻⁵ · τ\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/17","norm_bases":["IW/LW3/17"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. τ - wartość mierzona (s)","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. τ - measured value (s)","search_text":"Sekundomierze (stopery) mechaniczne Wzorcowanie — Czas (przedział czasu)\n0 h do 1 h CMC 0,07 s + 1,2 · 10⁻⁵ · τ\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/17 Sekundomierze (stopery) mechaniczne Wzorcowanie — Czas (przedzial czasu)\n0 h do 1 h CMC 0,07 s + 1,2 · 10⁻⁵ · τ\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/17","search_en":"Mechanical stopwatches Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) IW/LW3/17","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":53,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"0 h to 1 h","cmc":"0,07 s + 1,2 · 10⁻⁵ · τ"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Mechanische Stoppuhren Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) IW/LW3/17","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Mechanische Stoppuhren","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"0 h to 1 h","cmc":"0,07 s + 1,2 · 10⁻⁵ · τ"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"机械秒表 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) IW/LW3/17","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"机械秒表","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"0 h to 1 h","cmc":"0,07 s + 1,2 · 10⁻⁵ · τ"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Mechanické stopky Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) IW/LW3/17","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Mechanické stopky"},{"_id":"37d40a3da5644762010a3224","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Multimetry","test_object_en":"Multimeters","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"1 Hz do 25 MHz","cmc":"3 · 10⁻⁶ · f"}],"parameters_en":[{"name":"","range":"1 Hz to 25 MHz","cmc":"3 · 10⁻⁶ · f"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n1 Hz do 25 MHz CMC 3 · 10⁻⁶ · f\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"IW/LW3/02","norm_bases":["IW/LW3/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. f – wartość mierzona (Hz)","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz. f – measured value (Hz)","search_text":"Multimetry Wzorcowanie — Częstotliwość\n1 Hz do 25 MHz CMC 3 · 10⁻⁶ · f\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) IW/LW3/02 Multimetry Wzorcowanie — Czestotliwosc\n1 Hz do 25 MHz CMC 3 · 10⁻⁶ · f\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) IW/LW3/02","search_en":"Multimeters Calibration — Frequency Internal procedure; Direct method; At permanent location (S) Frequency Internal procedure Direct method At permanent location (S) IW/LW3/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":54,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"1 Hz to 25 MHz","cmc":"3 · 10⁻⁶ · f"}],"regulatory_area_de":"Frequenz","search_de":"Multimeter Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) IW/LW3/02","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"1 Hz to 25 MHz","cmc":"3 · 10⁻⁶ · f"}],"regulatory_area_zh":"频率","search_zh":"万用表 校准 — 频率 内部程序；直接法；在固定地点 (S) 频率 内部程序 直接法 在固定地点 (S) IW/LW3/02","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"万用表","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"1 Hz to 25 MHz","cmc":"3 · 10⁻⁶ · f"}],"regulatory_area_cs":"Frekvence","search_cs":"Multimetry Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Frekvence Vnitřní postup Přímá metoda Ve stálé lokalitě (S) IW/LW3/02","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry"},{"_id":"4f407679ab8b8357c8de7011","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Spektrofotometry (UV)","test_object_en":"Spectrophotometers (UV)","methodology":"Wzorcowanie — Gęstość optyczna widmowego współczynnika przepuszczania","methodology_en":"Calibration — Optical density of spectral transmittance","parameters":[{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"1,0836","cmc":"0,012"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"1,0762","cmc":"0,012"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"1,0672","cmc":"0,012"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,9864","cmc":"0,012"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,9464","cmc":"0,012"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,9500","cmc":"0,012"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,6129","cmc":"0,0097"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,6040","cmc":"0,0097"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,5945","cmc":"0,0096"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,5226","cmc":"0,0096"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,4929","cmc":"0,0096"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,4943","cmc":"0,0096"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,3022","cmc":"0,0081"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,2995","cmc":"0,0081"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,2971","cmc":"0,0081"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,2869","cmc":"0,0081"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,2887","cmc":"0,0081"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,2924","cmc":"0,0081"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,0335","cmc":"0,0069"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,0339","cmc":"0,0069"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,0341","cmc":"0,0069"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,0369","cmc":"0,0070"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,0394","cmc":"0,0070"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,0416","cmc":"0,0070"}],"parameters_en":[{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"1,0836","cmc":"0,012"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"1,0762","cmc":"0,012"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"1,0672","cmc":"0,012"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,9864","cmc":"0,012"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,9464","cmc":"0,012"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,9500","cmc":"0,012"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,6129","cmc":"0,0097"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,6040","cmc":"0,0097"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,5945","cmc":"0,0096"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,5226","cmc":"0,0096"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,4929","cmc":"0,0096"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,4943","cmc":"0,0096"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,3022","cmc":"0,0081"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,2995","cmc":"0,0081"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,2971","cmc":"0,0081"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,2869","cmc":"0,0081"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,2887","cmc":"0,0081"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,2924","cmc":"0,0081"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,0335","cmc":"0,0069"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,0339","cmc":"0,0069"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,0341","cmc":"0,0069"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,0369","cmc":"0,0070"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,0394","cmc":"0,0070"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,0416","cmc":"0,0070"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Gęstość optyczna widmowego współczynnika przepuszczania\nZakres:\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 1,0836 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 1,0762 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 1,0672 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9864 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9464 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9500 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,6129 CMC 0,0097\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,6040 CMC 0,0097\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5945 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5226 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,4929 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,4943 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,3022 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2995 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2971 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2869 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2887 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2924 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0335 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0339 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0341 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0369 CMC 0,0070\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0394 CMC 0,0070\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0416 CMC 0,0070\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"IW/LW3/10","norm_bases":["IW/LW3/10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Gęstość optyczna widmowego współczynnika przepuszczania","regulatory_area_en":"Optical density of spectral transmittance","outside_premises":true,"location_of_activity":"S, P","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Spektrofotometry (UV) Wzorcowanie — Gęstość optyczna widmowego współczynnika przepuszczania\nZakres:\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 1,0836 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 1,0762 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 1,0672 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9864 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9464 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9500 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,6129 CMC 0,0097\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,6040 CMC 0,0097\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5945 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5226 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,4929 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,4943 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,3022 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2995 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2971 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2869 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2887 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2924 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0335 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0339 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0341 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0369 CMC 0,0070\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0394 CMC 0,0070\nZakres widmowy 235 nm do 400 nm; Długości fali: (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0416 CMC 0,0070\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) IW/LW3/10 Spektrofotometry (UV) Wzorcowanie — Gestosc optyczna widmowego wspolczynnika przepuszczania\nZakres:\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 1,0836 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 1,0762 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 1,0672 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,9864 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,9464 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,9500 CMC 0,012\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,6129 CMC 0,0097\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,6040 CMC 0,0097\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,5945 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,5226 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,4929 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,4943 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,3022 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,2995 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,2971 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,2869 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,2887 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,2924 CMC 0,0081\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,0335 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,0339 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,0341 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,0369 CMC 0,0070\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,0394 CMC 0,0070\nZakres widmowy 235 nm do 400 nm; Dlugosci fali: (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,0416 CMC 0,0070\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) IW/LW3/10","search_en":"Spectrophotometers (UV) Calibration — Optical density of spectral transmittance Internal procedure; At permanent location (S) and outside of it (P) Optical density of spectral transmittance Internal procedure At permanent location (S) and outside of it (P) Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths: (360, 350, 340, 280, 250, 235) nm; The values given are nominal values IW/LW3/10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":55,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Optische Dichte des spektralen Transmissionsgrads","parameters_de":[{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"1,0836","cmc":"0,012"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"1,0762","cmc":"0,012"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"1,0672","cmc":"0,012"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,9864","cmc":"0,012"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,9464","cmc":"0,012"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,9500","cmc":"0,012"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,6129","cmc":"0,0097"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,6040","cmc":"0,0097"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,5945","cmc":"0,0096"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,5226","cmc":"0,0096"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,4929","cmc":"0,0096"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,4943","cmc":"0,0096"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,3022","cmc":"0,0081"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,2995","cmc":"0,0081"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,2971","cmc":"0,0081"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,2869","cmc":"0,0081"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,2887","cmc":"0,0081"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,2924","cmc":"0,0081"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,0335","cmc":"0,0069"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,0339","cmc":"0,0069"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,0341","cmc":"0,0069"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,0369","cmc":"0,0070"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,0394","cmc":"0,0070"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,0416","cmc":"0,0070"}],"regulatory_area_de":"Optische Dichte des spektralen Transmissionsgrads","search_de":"Spektralphotometer (UV) Kalibrierung — Optische Dichte des spektralen Transmissionsgrads Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Optische Dichte des spektralen Transmissionsgrads Internes Verfahren Am festen Standort (S) und außerhalb (P) Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen: (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte IW/LW3/10","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Spektralphotometer (UV)","methodology_zh":"校准 — 光谱透射比的光密度","parameters_zh":[{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"1,0836","cmc":"0,012"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"1,0762","cmc":"0,012"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"1,0672","cmc":"0,012"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,9864","cmc":"0,012"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,9464","cmc":"0,012"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,9500","cmc":"0,012"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,6129","cmc":"0,0097"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,6040","cmc":"0,0097"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,5945","cmc":"0,0096"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,5226","cmc":"0,0096"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,4929","cmc":"0,0096"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,4943","cmc":"0,0096"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,3022","cmc":"0,0081"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,2995","cmc":"0,0081"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,2971","cmc":"0,0081"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,2869","cmc":"0,0081"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,2887","cmc":"0,0081"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,2924","cmc":"0,0081"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,0335","cmc":"0,0069"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,0339","cmc":"0,0069"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,0341","cmc":"0,0069"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,0369","cmc":"0,0070"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,0394","cmc":"0,0070"},{"name":"光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,0416","cmc":"0,0070"}],"regulatory_area_zh":"光谱透射比的光密度","search_zh":"分光光度计（UV） 校准 — 光谱透射比的光密度 内部程序；在固定地点 (S) 及固定地点以外 (P) 光谱透射比的光密度 内部程序 在固定地点 (S) 及固定地点以外 (P) 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长：(360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 IW/LW3/10","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"分光光度计（UV）","methodology_cs":"Kalibrace — Optická hustota spektrální propustnosti","parameters_cs":[{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"1,0836","cmc":"0,012"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"1,0762","cmc":"0,012"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"1,0672","cmc":"0,012"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,9864","cmc":"0,012"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,9464","cmc":"0,012"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,9500","cmc":"0,012"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,6129","cmc":"0,0097"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,6040","cmc":"0,0097"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,5945","cmc":"0,0096"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,5226","cmc":"0,0096"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,4929","cmc":"0,0096"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,4943","cmc":"0,0096"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,3022","cmc":"0,0081"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,2995","cmc":"0,0081"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,2971","cmc":"0,0081"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,2869","cmc":"0,0081"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,2887","cmc":"0,0081"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,2924","cmc":"0,0081"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,0335","cmc":"0,0069"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,0339","cmc":"0,0069"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,0341","cmc":"0,0069"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,0369","cmc":"0,0070"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,0394","cmc":"0,0070"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,0416","cmc":"0,0070"}],"regulatory_area_cs":"Optická hustota spektrální propustnosti","search_cs":"Spektrofotometry (UV) Kalibrace — Optická hustota spektrální propustnosti Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Optická hustota spektrální propustnosti Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky: (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty IW/LW3/10","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Spektrofotometry (UV)"},{"_id":"2d8a0174b10619c22cd2617b","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Spektrofotometry (VIS)","test_object_en":"Spectrophotometers (VIS)","methodology":"Wzorcowanie — Gęstość optyczna widmowego współczynnika przepuszczania","methodology_en":"Calibration — Optical density of spectral transmittance","parameters":[{"name":"Zakres widmowy 400 nm do 890 nm","range":"0 do 0,3","cmc":"0,0036"},{"name":"Zakres widmowy 400 nm do 890 nm","range":"0,3 do 0,5","cmc":"0,0042"},{"name":"Zakres widmowy 400 nm do 890 nm","range":"0,5 do 1,0","cmc":"0,0050"},{"name":"Zakres widmowy 400 nm do 890 nm","range":"1,0 do 1,4","cmc":"0,0077"}],"parameters_en":[{"name":"Zakres widmowy 400 nm to 890 nm","range":"0 to 0,3","cmc":"0,0036"},{"name":"Zakres widmowy 400 nm to 890 nm","range":"0,3 to 0,5","cmc":"0,0042"},{"name":"Zakres widmowy 400 nm to 890 nm","range":"0,5 to 1,0","cmc":"0,0050"},{"name":"Zakres widmowy 400 nm to 890 nm","range":"1,0 to 1,4","cmc":"0,0077"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Gęstość optyczna widmowego współczynnika przepuszczania\nZakres:\nZakres widmowy 400 nm do 890 nm 0 do 0,3 CMC 0,0036\nZakres widmowy 400 nm do 890 nm 0,3 do 0,5 CMC 0,0042\nZakres widmowy 400 nm do 890 nm 0,5 do 1,0 CMC 0,0050\nZakres widmowy 400 nm do 890 nm 1,0 do 1,4 CMC 0,0077\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"IW/LW3/10","norm_bases":["IW/LW3/10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Gęstość optyczna widmowego współczynnika przepuszczania","regulatory_area_en":"Optical density of spectral transmittance","outside_premises":true,"location_of_activity":"S, P","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Spektrofotometry (VIS) Wzorcowanie — Gęstość optyczna widmowego współczynnika przepuszczania\nZakres:\nZakres widmowy 400 nm do 890 nm 0 do 0,3 CMC 0,0036\nZakres widmowy 400 nm do 890 nm 0,3 do 0,5 CMC 0,0042\nZakres widmowy 400 nm do 890 nm 0,5 do 1,0 CMC 0,0050\nZakres widmowy 400 nm do 890 nm 1,0 do 1,4 CMC 0,0077\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) IW/LW3/10 Spektrofotometry (VIS) Wzorcowanie — Gestosc optyczna widmowego wspolczynnika przepuszczania\nZakres:\nZakres widmowy 400 nm do 890 nm 0 do 0,3 CMC 0,0036\nZakres widmowy 400 nm do 890 nm 0,3 do 0,5 CMC 0,0042\nZakres widmowy 400 nm do 890 nm 0,5 do 1,0 CMC 0,0050\nZakres widmowy 400 nm do 890 nm 1,0 do 1,4 CMC 0,0077\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) IW/LW3/10","search_en":"Spectrophotometers (VIS) Calibration — Optical density of spectral transmittance Internal procedure; At permanent location (S) and outside of it (P) Optical density of spectral transmittance Internal procedure At permanent location (S) and outside of it (P) Zakres widmowy 400 nm to 890 nm Zakres widmowy 400 nm to 890 nm Zakres widmowy 400 nm to 890 nm Zakres widmowy 400 nm to 890 nm IW/LW3/10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":56,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Optische Dichte des spektralen Transmissionsgrads","parameters_de":[{"name":"Spektralbereich 400 nm bis 890 nm","range":"0 to 0,3","cmc":"0,0036"},{"name":"Spektralbereich 400 nm bis 890 nm","range":"0,3 to 0,5","cmc":"0,0042"},{"name":"Spektralbereich 400 nm bis 890 nm","range":"0,5 to 1,0","cmc":"0,0050"},{"name":"Spektralbereich 400 nm bis 890 nm","range":"1,0 to 1,4","cmc":"0,0077"}],"regulatory_area_de":"Optische Dichte des spektralen Transmissionsgrads","search_de":"Spektralphotometer (VIS) Kalibrierung — Optische Dichte des spektralen Transmissionsgrads Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Optische Dichte des spektralen Transmissionsgrads Internes Verfahren Am festen Standort (S) und außerhalb (P) Spektralbereich 400 nm bis 890 nm Spektralbereich 400 nm bis 890 nm Spektralbereich 400 nm bis 890 nm Spektralbereich 400 nm bis 890 nm IW/LW3/10","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Spektralphotometer (VIS)","methodology_zh":"校准 — 光谱透射比的光密度","parameters_zh":[{"name":"光谱范围 400 nm 至 890 nm","range":"0 to 0,3","cmc":"0,0036"},{"name":"光谱范围 400 nm 至 890 nm","range":"0,3 to 0,5","cmc":"0,0042"},{"name":"光谱范围 400 nm 至 890 nm","range":"0,5 to 1,0","cmc":"0,0050"},{"name":"光谱范围 400 nm 至 890 nm","range":"1,0 to 1,4","cmc":"0,0077"}],"regulatory_area_zh":"光谱透射比的光密度","search_zh":"分光光度计（VIS） 校准 — 光谱透射比的光密度 内部程序；在固定地点 (S) 及固定地点以外 (P) 光谱透射比的光密度 内部程序 在固定地点 (S) 及固定地点以外 (P) 光谱范围 400 nm 至 890 nm 光谱范围 400 nm 至 890 nm 光谱范围 400 nm 至 890 nm 光谱范围 400 nm 至 890 nm IW/LW3/10","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"分光光度计（VIS）","methodology_cs":"Kalibrace — Optická hustota spektrální propustnosti","parameters_cs":[{"name":"Spektrální rozsah 400 nm až 890 nm","range":"0 to 0,3","cmc":"0,0036"},{"name":"Spektrální rozsah 400 nm až 890 nm","range":"0,3 to 0,5","cmc":"0,0042"},{"name":"Spektrální rozsah 400 nm až 890 nm","range":"0,5 to 1,0","cmc":"0,0050"},{"name":"Spektrální rozsah 400 nm až 890 nm","range":"1,0 to 1,4","cmc":"0,0077"}],"regulatory_area_cs":"Optická hustota spektrální propustnosti","search_cs":"Spektrofotometry (VIS) Kalibrace — Optická hustota spektrální propustnosti Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Optická hustota spektrální propustnosti Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) Spektrální rozsah 400 nm až 890 nm Spektrální rozsah 400 nm až 890 nm Spektrální rozsah 400 nm až 890 nm Spektrální rozsah 400 nm až 890 nm IW/LW3/10","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Spektrofotometry (VIS)"},{"_id":"947973b52faf683c552c37b2","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Spektrofotometry (UV)","test_object_en":"Spectrophotometers (UV)","methodology":"Wzorcowanie — Widmowy współczynnik przepuszczania","methodology_en":"Calibration — Spectral transmittance","parameters":[{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,0825","cmc":"0,0037"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,0839","cmc":"0,0037"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,0857","cmc":"0,0037"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,1032","cmc":"0,0037"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,1131","cmc":"0,0037"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,1122","cmc":"0,0037"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,2438","cmc":"0,0068"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,2489","cmc":"0,0068"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,2544","cmc":"0,0068"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,3002","cmc":"0,0069"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,3214","cmc":"0,0069"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,3204","cmc":"0,0069"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,4986","cmc":"0,0095"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,5018","cmc":"0,0096"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,5046","cmc":"0,0096"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,5165","cmc":"0,0096"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,5144","cmc":"0,0096"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,5100","cmc":"0,0096"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,9258","cmc":"0,014"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,9249","cmc":"0,014"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,9245","cmc":"0,014"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,9185","cmc":"0,014"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,9132","cmc":"0,014"},{"name":"Zakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi","range":"0,9086","cmc":"0,014"}],"parameters_en":[{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,0825","cmc":"0,0037"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,0839","cmc":"0,0037"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,0857","cmc":"0,0037"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,1032","cmc":"0,0037"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,1131","cmc":"0,0037"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,1122","cmc":"0,0037"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,2438","cmc":"0,0068"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,2489","cmc":"0,0068"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,2544","cmc":"0,0068"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,3002","cmc":"0,0069"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,3214","cmc":"0,0069"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,3204","cmc":"0,0069"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,4986","cmc":"0,0095"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,5018","cmc":"0,0096"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,5046","cmc":"0,0096"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,5165","cmc":"0,0096"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,5144","cmc":"0,0096"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,5100","cmc":"0,0096"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,9258","cmc":"0,014"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,9249","cmc":"0,014"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,9245","cmc":"0,014"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,9185","cmc":"0,014"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,9132","cmc":"0,014"},{"name":"Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values","range":"0,9086","cmc":"0,014"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Widmowy współczynnik przepuszczania\nZakres:\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0825 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0839 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0857 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,1032 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,1131 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,1122 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2438 CMC 0,0068\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2489 CMC 0,0068\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2544 CMC 0,0068\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,3002 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,3214 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,3204 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,4986 CMC 0,0095\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5018 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5046 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5165 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5144 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5100 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9258 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9249 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9245 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9185 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9132 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9086 CMC 0,014\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"IW/LW3/10","norm_bases":["IW/LW3/10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Widmowy współczynnik przepuszczania","regulatory_area_en":"Spectral transmittance","outside_premises":true,"location_of_activity":"S, P","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Spektrofotometry (UV) Wzorcowanie — Widmowy współczynnik przepuszczania\nZakres:\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0825 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0839 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,0857 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,1032 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,1131 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,1122 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2438 CMC 0,0068\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2489 CMC 0,0068\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,2544 CMC 0,0068\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,3002 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,3214 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,3204 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,4986 CMC 0,0095\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5018 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5046 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5165 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5144 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,5100 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9258 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9249 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9245 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9185 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9132 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Długości fali (360, 350, 340, 280, 250, 235) nm; Podane wartości są wartościami nominalnymi 0,9086 CMC 0,014\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) IW/LW3/10 Spektrofotometry (UV) Wzorcowanie — Widmowy wspolczynnik przepuszczania\nZakres:\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,0825 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,0839 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,0857 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,1032 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,1131 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,1122 CMC 0,0037\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,2438 CMC 0,0068\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,2489 CMC 0,0068\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,2544 CMC 0,0068\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,3002 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,3214 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,3204 CMC 0,0069\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,4986 CMC 0,0095\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,5018 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,5046 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,5165 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,5144 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,5100 CMC 0,0096\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,9258 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,9249 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,9245 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,9185 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,9132 CMC 0,014\nZakres widmowy 235 nm do 400 nm; Dlugosci fali (360, 350, 340, 280, 250, 235) nm; Podane wartosci sa wartosciami nominalnymi 0,9086 CMC 0,014\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) IW/LW3/10","search_en":"Spectrophotometers (UV) Calibration — Spectral transmittance Internal procedure; At permanent location (S) and outside of it (P) Spectral transmittance Internal procedure At permanent location (S) and outside of it (P) Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values Spectral range 235 nm to 400 nm; Wavelengths (360, 350, 340, 280, 250, 235) nm; The values given are nominal values IW/LW3/10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":57,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Spektraler Transmissionsgrad","parameters_de":[{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,0825","cmc":"0,0037"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,0839","cmc":"0,0037"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,0857","cmc":"0,0037"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,1032","cmc":"0,0037"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,1131","cmc":"0,0037"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,1122","cmc":"0,0037"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,2438","cmc":"0,0068"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,2489","cmc":"0,0068"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,2544","cmc":"0,0068"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,3002","cmc":"0,0069"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,3214","cmc":"0,0069"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,3204","cmc":"0,0069"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,4986","cmc":"0,0095"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,5018","cmc":"0,0096"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,5046","cmc":"0,0096"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,5165","cmc":"0,0096"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,5144","cmc":"0,0096"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,5100","cmc":"0,0096"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,9258","cmc":"0,014"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,9249","cmc":"0,014"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,9245","cmc":"0,014"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,9185","cmc":"0,014"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,9132","cmc":"0,014"},{"name":"Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte","range":"0,9086","cmc":"0,014"}],"regulatory_area_de":"Spektraler Transmissionsgrad","search_de":"Spektralphotometer (UV) Kalibrierung — Spektraler Transmissionsgrad Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Spektraler Transmissionsgrad Internes Verfahren Am festen Standort (S) und außerhalb (P) Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte Spektralbereich 235 nm bis 400 nm; Wellenlängen (360, 350, 340, 280, 250, 235) nm; Die angegebenen Werte sind Nennwerte IW/LW3/10","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Spektralphotometer (UV)","methodology_zh":"校准 — 光谱透射比","parameters_zh":[{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,0825","cmc":"0,0037"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,0839","cmc":"0,0037"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,0857","cmc":"0,0037"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,1032","cmc":"0,0037"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,1131","cmc":"0,0037"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,1122","cmc":"0,0037"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,2438","cmc":"0,0068"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,2489","cmc":"0,0068"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,2544","cmc":"0,0068"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,3002","cmc":"0,0069"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,3214","cmc":"0,0069"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,3204","cmc":"0,0069"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,4986","cmc":"0,0095"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,5018","cmc":"0,0096"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,5046","cmc":"0,0096"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,5165","cmc":"0,0096"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,5144","cmc":"0,0096"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,5100","cmc":"0,0096"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,9258","cmc":"0,014"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,9249","cmc":"0,014"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,9245","cmc":"0,014"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,9185","cmc":"0,014"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,9132","cmc":"0,014"},{"name":"光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值","range":"0,9086","cmc":"0,014"}],"regulatory_area_zh":"光谱透射比","search_zh":"分光光度计（UV） 校准 — 光谱透射比 内部程序；在固定地点 (S) 及固定地点以外 (P) 光谱透射比 内部程序 在固定地点 (S) 及固定地点以外 (P) 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 光谱范围 235 nm 至 400 nm; 波长 (360, 350, 340, 280, 250, 235) nm; 所给数值为标称值 IW/LW3/10","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"分光光度计（UV）","methodology_cs":"Kalibrace — Spektrální propustnost","parameters_cs":[{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,0825","cmc":"0,0037"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,0839","cmc":"0,0037"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,0857","cmc":"0,0037"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,1032","cmc":"0,0037"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,1131","cmc":"0,0037"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,1122","cmc":"0,0037"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,2438","cmc":"0,0068"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,2489","cmc":"0,0068"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,2544","cmc":"0,0068"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,3002","cmc":"0,0069"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,3214","cmc":"0,0069"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,3204","cmc":"0,0069"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,4986","cmc":"0,0095"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,5018","cmc":"0,0096"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,5046","cmc":"0,0096"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,5165","cmc":"0,0096"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,5144","cmc":"0,0096"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,5100","cmc":"0,0096"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,9258","cmc":"0,014"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,9249","cmc":"0,014"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,9245","cmc":"0,014"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,9185","cmc":"0,014"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,9132","cmc":"0,014"},{"name":"Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty","range":"0,9086","cmc":"0,014"}],"regulatory_area_cs":"Spektrální propustnost","search_cs":"Spektrofotometry (UV) Kalibrace — Spektrální propustnost Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Spektrální propustnost Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty Spektrální rozsah 235 nm až 400 nm; Vlnové délky (360, 350, 340, 280, 250, 235) nm; Uvedené hodnoty jsou jmenovité hodnoty IW/LW3/10","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Spektrofotometry (UV)"},{"_id":"f46b030c374552eda9c70f19","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Spektrofotometry (VIS)","test_object_en":"Spectrophotometers (VIS)","methodology":"Wzorcowanie — Widmowy współczynnik przepuszczania","methodology_en":"Calibration — Spectral transmittance","parameters":[{"name":"Zakres widmowy 400 nm do 890 nm","range":"0,04 do 0,10","cmc":"0,0027"},{"name":"Zakres widmowy 400 nm do 890 nm","range":"0,1 do 0,3","cmc":"0,0028"},{"name":"Zakres widmowy 400 nm do 890 nm","range":"0,3 do 0,5","cmc":"0,0038"},{"name":"Zakres widmowy 400 nm do 890 nm","range":"0,5 do 1,0","cmc":"0,0052"}],"parameters_en":[{"name":"Zakres widmowy 400 nm to 890 nm","range":"0,04 to 0,10","cmc":"0,0027"},{"name":"Zakres widmowy 400 nm to 890 nm","range":"0,1 to 0,3","cmc":"0,0028"},{"name":"Zakres widmowy 400 nm to 890 nm","range":"0,3 to 0,5","cmc":"0,0038"},{"name":"Zakres widmowy 400 nm to 890 nm","range":"0,5 to 1,0","cmc":"0,0052"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Widmowy współczynnik przepuszczania\nZakres:\nZakres widmowy 400 nm do 890 nm 0,04 do 0,10 CMC 0,0027\nZakres widmowy 400 nm do 890 nm 0,1 do 0,3 CMC 0,0028\nZakres widmowy 400 nm do 890 nm 0,3 do 0,5 CMC 0,0038\nZakres widmowy 400 nm do 890 nm 0,5 do 1,0 CMC 0,0052\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"IW/LW3/10","norm_bases":["IW/LW3/10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Widmowy współczynnik przepuszczania","regulatory_area_en":"Spectral transmittance","outside_premises":true,"location_of_activity":"S, P","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Spektrofotometry (VIS) Wzorcowanie — Widmowy współczynnik przepuszczania\nZakres:\nZakres widmowy 400 nm do 890 nm 0,04 do 0,10 CMC 0,0027\nZakres widmowy 400 nm do 890 nm 0,1 do 0,3 CMC 0,0028\nZakres widmowy 400 nm do 890 nm 0,3 do 0,5 CMC 0,0038\nZakres widmowy 400 nm do 890 nm 0,5 do 1,0 CMC 0,0052\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) IW/LW3/10 Spektrofotometry (VIS) Wzorcowanie — Widmowy wspolczynnik przepuszczania\nZakres:\nZakres widmowy 400 nm do 890 nm 0,04 do 0,10 CMC 0,0027\nZakres widmowy 400 nm do 890 nm 0,1 do 0,3 CMC 0,0028\nZakres widmowy 400 nm do 890 nm 0,3 do 0,5 CMC 0,0038\nZakres widmowy 400 nm do 890 nm 0,5 do 1,0 CMC 0,0052\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) IW/LW3/10","search_en":"Spectrophotometers (VIS) Calibration — Spectral transmittance Internal procedure; At permanent location (S) and outside of it (P) Spectral transmittance Internal procedure At permanent location (S) and outside of it (P) Zakres widmowy 400 nm to 890 nm Zakres widmowy 400 nm to 890 nm Zakres widmowy 400 nm to 890 nm Zakres widmowy 400 nm to 890 nm IW/LW3/10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":58,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Spektraler Transmissionsgrad","parameters_de":[{"name":"Spektralbereich 400 nm bis 890 nm","range":"0,04 to 0,10","cmc":"0,0027"},{"name":"Spektralbereich 400 nm bis 890 nm","range":"0,1 to 0,3","cmc":"0,0028"},{"name":"Spektralbereich 400 nm bis 890 nm","range":"0,3 to 0,5","cmc":"0,0038"},{"name":"Spektralbereich 400 nm bis 890 nm","range":"0,5 to 1,0","cmc":"0,0052"}],"regulatory_area_de":"Spektraler Transmissionsgrad","search_de":"Spektralphotometer (VIS) Kalibrierung — Spektraler Transmissionsgrad Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Spektraler Transmissionsgrad Internes Verfahren Am festen Standort (S) und außerhalb (P) Spektralbereich 400 nm bis 890 nm Spektralbereich 400 nm bis 890 nm Spektralbereich 400 nm bis 890 nm Spektralbereich 400 nm bis 890 nm IW/LW3/10","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Spektralphotometer (VIS)","methodology_zh":"校准 — 光谱透射比","parameters_zh":[{"name":"光谱范围 400 nm 至 890 nm","range":"0,04 to 0,10","cmc":"0,0027"},{"name":"光谱范围 400 nm 至 890 nm","range":"0,1 to 0,3","cmc":"0,0028"},{"name":"光谱范围 400 nm 至 890 nm","range":"0,3 to 0,5","cmc":"0,0038"},{"name":"光谱范围 400 nm 至 890 nm","range":"0,5 to 1,0","cmc":"0,0052"}],"regulatory_area_zh":"光谱透射比","search_zh":"分光光度计（VIS） 校准 — 光谱透射比 内部程序；在固定地点 (S) 及固定地点以外 (P) 光谱透射比 内部程序 在固定地点 (S) 及固定地点以外 (P) 光谱范围 400 nm 至 890 nm 光谱范围 400 nm 至 890 nm 光谱范围 400 nm 至 890 nm 光谱范围 400 nm 至 890 nm IW/LW3/10","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"分光光度计（VIS）","methodology_cs":"Kalibrace — Spektrální propustnost","parameters_cs":[{"name":"Spektrální rozsah 400 nm až 890 nm","range":"0,04 to 0,10","cmc":"0,0027"},{"name":"Spektrální rozsah 400 nm až 890 nm","range":"0,1 to 0,3","cmc":"0,0028"},{"name":"Spektrální rozsah 400 nm až 890 nm","range":"0,3 to 0,5","cmc":"0,0038"},{"name":"Spektrální rozsah 400 nm až 890 nm","range":"0,5 to 1,0","cmc":"0,0052"}],"regulatory_area_cs":"Spektrální propustnost","search_cs":"Spektrofotometry (VIS) Kalibrace — Spektrální propustnost Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Spektrální propustnost Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) Spektrální rozsah 400 nm až 890 nm Spektrální rozsah 400 nm až 890 nm Spektrální rozsah 400 nm až 890 nm Spektrální rozsah 400 nm až 890 nm IW/LW3/10","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Spektrofotometry (VIS)"},{"_id":"7deae335276ffd725bc947db","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Spektrofotometry","test_object_en":"Spectrophotometers","methodology":"Wzorcowanie — Widmowy współczynnik przepuszczania","methodology_en":"Calibration — Spectral transmittance","parameters":[{"name":"- długość fali","range":"275 nm do 890 nm","cmc":"0,20 nm (osiągana dla połówkowej szerokości widmowej szczeliny wyjściowej 1 nm)"}],"parameters_en":[{"name":"wavelength","range":"275 nm to 890 nm","cmc":"0,20 nm (achieved for a spectral half-width of the exit slit of 1 nm)"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Widmowy współczynnik przepuszczania\n- długość fali 275 nm do 890 nm CMC 0,20 nm (osiągana dla połówkowej szerokości widmowej szczeliny wyjściowej 1 nm)\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"IW/LW3/10","norm_bases":["IW/LW3/10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Widmowy współczynnik przepuszczania","regulatory_area_en":"Spectral transmittance","outside_premises":true,"location_of_activity":"S, P","note":"Laboratorium Elektryczności, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","note_en":"Electricity Laboratory, ul. Królowej Jadwigi 25, 85-231 Bydgoszcz","search_text":"Spektrofotometry Wzorcowanie — Widmowy współczynnik przepuszczania\n- długość fali 275 nm do 890 nm CMC 0,20 nm (osiągana dla połówkowej szerokości widmowej szczeliny wyjściowej 1 nm)\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) IW/LW3/10 Spektrofotometry Wzorcowanie — Widmowy wspolczynnik przepuszczania\n- dlugosc fali 275 nm do 890 nm CMC 0,20 nm (osiagana dla polowkowej szerokosci widmowej szczeliny wyjsciowej 1 nm)\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) IW/LW3/10","search_en":"Spectrophotometers Calibration — Spectral transmittance Internal procedure; At permanent location (S) and outside of it (P) Spectral transmittance Internal procedure At permanent location (S) and outside of it (P) wavelength IW/LW3/10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":59,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Spektraler Transmissionsgrad","parameters_de":[{"name":"- Wellenlänge","range":"275 nm to 890 nm","cmc":"0,20 nm (erreicht bei einer spektralen Halbwertsbreite des Austrittsspalts von 1 nm)"}],"regulatory_area_de":"Spektraler Transmissionsgrad","search_de":"Spektralphotometer Kalibrierung — Spektraler Transmissionsgrad Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Spektraler Transmissionsgrad Internes Verfahren Am festen Standort (S) und außerhalb (P) - Wellenlänge IW/LW3/10","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Spektralphotometer","methodology_zh":"校准 — 光谱透射比","parameters_zh":[{"name":"- 波长","range":"275 nm to 890 nm","cmc":"0,20 nm（在出射狭缝光谱半宽 1 nm 时达到）"}],"regulatory_area_zh":"光谱透射比","search_zh":"分光光度计 校准 — 光谱透射比 内部程序；在固定地点 (S) 及固定地点以外 (P) 光谱透射比 内部程序 在固定地点 (S) 及固定地点以外 (P) - 波长 IW/LW3/10","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"分光光度计","methodology_cs":"Kalibrace — Spektrální propustnost","parameters_cs":[{"name":"- vlnová délka","range":"275 nm to 890 nm","cmc":"0,20 nm (dosažená při spektrální pološířce výstupní štěrbiny 1 nm)"}],"regulatory_area_cs":"Spektrální propustnost","search_cs":"Spektrofotometry Kalibrace — Spektrální propustnost Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Spektrální propustnost Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) - vlnová délka IW/LW3/10","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Spektrofotometry"},{"_id":"0ba5ae9d01dcc327074f3532","lab_id":"6afad8088989a133b76447c2","country":"PL","accr_number":"AP 088","accr_body":"PCA","test_object":"Termometry szklane cieczowe","test_object_en":"Liquid-in-glass thermometers","methodology":"Wzorcowanie — Temperatura (termometria nieelektryczna)","methodology_en":"Calibration — Temperature (non-electrical thermometry)","parameters":[{"name":"","range":"-40 °C do -1 °C","cmc":"0,07 °C"},{"name":"","range":"1 °C do 100 °C","cmc":"0,06 °C"},{"name":"","range":"101 °C do 250 °C","cmc":"0,13 °C"},{"name":"","range":"251 °C do 360 °C","cmc":"0,36 °C"},{"name":"","range":"0 °C","cmc":"0,02 °C"}],"parameters_en":[{"name":"","range":"-40 °C to -1 °C","cmc":"0,07 °C"},{"name":"","range":"1 °C to 100 °C","cmc":"0,06 °C"},{"name":"","range":"101 °C to 250 °C","cmc":"0,13 °C"},{"name":"","range":"251 °C to 360 °C","cmc":"0,36 °C"},{"name":"","range":"0 °C","cmc":"0,02 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-40 °C do -1 °C CMC 0,07 °C\n1 °C do 100 °C CMC 0,06 °C\n101 °C do 250 °C CMC 0,13 °C\n251 °C do 360 °C CMC 0,36 °C\n0 °C CMC 0,02 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"IW/LW1/06 w oparciu o OIML R 133:2002","norm_bases":["IW/LW1/06","OIML R 133:2002"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria nieelektryczna)","regulatory_area_en":"Temperature (non-electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":"Pracownia Temperatury, ul. Toruńska 104, 87-800 Włocławek","note_en":"Temperature Laboratory, ul. Toruńska 104, 87-800 Włocławek","search_text":"Termometry szklane cieczowe Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-40 °C do -1 °C CMC 0,07 °C\n1 °C do 100 °C CMC 0,06 °C\n101 °C do 250 °C CMC 0,13 °C\n251 °C do 360 °C CMC 0,36 °C\n0 °C CMC 0,02 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) IW/LW1/06 w oparciu o OIML R 133:2002 Termometry szklane cieczowe Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-40 °C do -1 °C CMC 0,07 °C\n1 °C do 100 °C CMC 0,06 °C\n101 °C do 250 °C CMC 0,13 °C\n251 °C do 360 °C CMC 0,36 °C\n0 °C CMC 0,02 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) IW/LW1/06 w oparciu o OIML R 133:2002","search_en":"Liquid-in-glass thermometers Calibration — Temperature (non-electrical thermometry) Internal procedure; At permanent location (S) Temperature (non-electrical thermometry) Internal procedure At permanent location (S) IW/LW1/06 based on OIML R 133:2002","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":60,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"IW/LW1/06 based on OIML R 133:2002","methodology_de":"Kalibrierung — Temperatur (nichtelektrische Thermometrie)","parameters_de":[{"name":"","range":"-40 °C to -1 °C","cmc":"0,07 °C"},{"name":"","range":"1 °C to 100 °C","cmc":"0,06 °C"},{"name":"","range":"101 °C to 250 °C","cmc":"0,13 °C"},{"name":"","range":"251 °C to 360 °C","cmc":"0,36 °C"},{"name":"","range":"0 °C","cmc":"0,02 °C"}],"reference_de":"IW/LW1/06 auf Grundlage von OIML R 133:2002","regulatory_area_de":"Temperatur (nichtelektrische Thermometrie)","search_de":"Flüssigkeits-Glasthermometer Kalibrierung — Temperatur (nichtelektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (nichtelektrische Thermometrie) Internes Verfahren Am festen Standort (S) IW/LW1/06 auf Grundlage von OIML R 133:2002","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Flüssigkeits-Glasthermometer","methodology_zh":"校准 — 温度（非电测温）","parameters_zh":[{"name":"","range":"-40 °C to -1 °C","cmc":"0,07 °C"},{"name":"","range":"1 °C to 100 °C","cmc":"0,06 °C"},{"name":"","range":"101 °C to 250 °C","cmc":"0,13 °C"},{"name":"","range":"251 °C to 360 °C","cmc":"0,36 °C"},{"name":"","range":"0 °C","cmc":"0,02 °C"}],"reference_zh":"IW/LW1/06 依据OIML R 133:2002","regulatory_area_zh":"温度（非电测温）","search_zh":"玻璃液体温度计 校准 — 温度（非电测温） 内部程序；在固定地点 (S) 温度（非电测温） 内部程序 在固定地点 (S) IW/LW1/06 依据OIML R 133:2002","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"玻璃液体温度计","methodology_cs":"Kalibrace — Teplota (neelektrická termometrie)","parameters_cs":[{"name":"","range":"-40 °C to -1 °C","cmc":"0,07 °C"},{"name":"","range":"1 °C to 100 °C","cmc":"0,06 °C"},{"name":"","range":"101 °C to 250 °C","cmc":"0,13 °C"},{"name":"","range":"251 °C to 360 °C","cmc":"0,36 °C"},{"name":"","range":"0 °C","cmc":"0,02 °C"}],"reference_cs":"IW/LW1/06 na základě OIML R 133:2002","regulatory_area_cs":"Teplota (neelektrická termometrie)","search_cs":"Skleněné kapalinové teploměry Kalibrace — Teplota (neelektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (neelektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) IW/LW1/06 na základě OIML R 133:2002","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Skleněné kapalinové teploměry"}],"has_pdf":true}