Okręgowy Urząd Miar w Łodzi is a calibration laboratory accredited by PCA under number AP 087 (Łódź, Poland). Its accreditation scope covers 99 calibration items in the following areas: Metrology & calibration. Calibrated items include: Multimeters, Spectrophotometers, Calibrators, Sound level meters. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; At permanent location (S) and outside of it (P), At permanent location (S).

At a glance

  • Accreditation number: PCA AP 087
  • Calibration items in scope: 99
  • Types of calibrated items: 119
  • Calibration principles used: 18
  • City: Łódź, Poland
  • Valid until: 18-01-2030
Accreditation number
AP 087
Accreditation body
PCA
Address
ul. Narutowicza 75, 90-132 Łódź
City
Łódź, Poland
Division
Calibration Laboratories Group
Valid until
18-01-2030

What this laboratory calibrates (119)

Calibration principles (18)

Certificate information

Issue date
15.01.2026
Issue no.
27
Certificate date
30.03.2020
Accreditation cycle
15.01.2026 — 18.01.2030
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (99)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. A value expressed as a percentage is the relative measurement uncertainty and refers to the percentage share of the value of the measurand. In other cases the uncertainty covered by the CMC is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Pure-tone audiometers Calibration — Sound pressure (sounds in air)
air conduction path - sound pressure level expressed as hearing level; frequency range 125 Hz to 8 kHz — 20 dB to 130 dB · CMC 0,6 dB air conduction path - sound pressure level expressed as masking level; for masking noise centre frequencies 125 Hz to 8 kHz — 20 dB to 130 dB · CMC 0,6 dB bone conduction path - dynamic force level expressed as hearing level; re 1 µN, frequency range 250 Hz to 4 kHz — -10 dB to 100 dB · CMC 0,7 dB
Sound pressure (sounds in air)
At permanent location (S) PN-EN 60645-1:2017
2 Octave and 1/3-octave band filters Calibration — Sound pressure (sounds in air)
relative attenuation of filters; 0 dB to 100 dB; filter centre frequencies from 20 Hz from 20 kHz — ≤ 50 dB · CMC 0,2 dB relative attenuation of filters; 0 dB to 100 dB; filter centre frequencies from 20 Hz from 20 kHz — > 50 dB · CMC 0,3 dB response of the sound level meter with band filters to electrical test signals; re 20 µPa, filter centre frequency range from 20 Hz to 20 kHz — 0 dB to 145 dB · CMC 0,2 dB
Sound pressure (sounds in air)
At permanent location (S) PN-EN 61260:2000 PN-EN 61260-3:2016
3 Personal sound exposure meters Calibration — Sound pressure (sounds in air)
response of the sound exposure meter to the sound calibrator signal; sound pressure level of the calibrator — 90 dB to 120 dB, measurement time 60 s to 130 s · CMC 3,8 % response of the sound exposure meter to electrical test signals; sound exposure range; frequency range: 63 Hz to 8 kHz — 0,3 Pa²h to 105 Pa²h · CMC 2,5 % free-field frequency response of the sound exposure meter, expressed in dB re 20 µPa; frequency range: — 63 Hz to 4 kHz · CMC 0,3 dB free-field frequency response of the sound exposure meter, expressed in dB re 20 µPa; frequency range: — 8 kHz · CMC 0,4 dB
Sound pressure (sounds in air)
At permanent location (S) PN-EN 61252:2000
4 Sound calibrator Calibration — Sound pressure (sounds in air)
sound pressure level; re 20 µPa, nominal frequencies 250 Hz, 1 kHz — 90 dB to 130 dB · CMC 0,09 dB
Sound pressure (sounds in air)
At permanent location (S) PN-EN 60942:2005 PN-EN 60942:2018
5 Sound level meters Calibration — Sound pressure (sounds in air)
response of the sound level meter to the sound calibrator signal; re 20 µPa — 90 dB to 130 dB · CMC 0,2 dB
Sound pressure (sounds in air)
At permanent location (S) PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007
6 Sound level meters Calibration — Sound pressure (sounds in air)
response of the sound level meter to electrical test signals; re 20 µPa, frequency range from 20 Hz to 20 kHz — 0 dB to 145 dB · CMC 0,2 dB
Sound pressure (sounds in air)
At permanent location (S) PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007
7 Sound level meters Calibration — Sound pressure (sounds in air)
free-field frequency response of the sound level meter; Frequency range — 20 Hz to 63 Hz, · CMC 0,2 dB free-field frequency response of the sound level meter; Frequency range — 125 Hz to 2 kHz, · CMC 0,2 dB free-field frequency response of the sound level meter; Frequency range — 2,5 kHz to 8 kHz, · CMC 0,2 dB free-field frequency response of the sound level meter; Frequency range — 10 kHz to 16 kHz, · CMC 0,4 dB free-field frequency response of the sound level meter; Frequency range — 20 kHz · CMC 0,5 dB
Sound pressure (sounds in air)
At permanent location (S) PN-EN 60651:2002 PN-EN 60804:2002
8 Sound level meters Calibration — Sound pressure (sounds in air)
free-field frequency response of the sound level meter; Frequencies: — 125 Hz · CMC 0,3 dB free-field frequency response of the sound level meter; Frequencies: — 1 kHz · CMC 0,3 dB free-field frequency response of the sound level meter; Frequencies: — 4 kHz · CMC 0,3 dB free-field frequency response of the sound level meter; Frequencies: — 8 kHz · CMC 0,4 dB
Sound pressure (sounds in air)
At permanent location (S) PN-EN 61672-3:2007
9 Vibration calibrators Calibration — Vibration acceleration
3,16 ms⁻² for 159,2 Hz · CMC 0,8 % 10 ms⁻² for 79,6 Hz · CMC 0,8 % 10 ms⁻² for 159,2 Hz · CMC 0,8 % 1 ms⁻² for 16 Hz · CMC 1,0 %
Vibration acceleration
Internal procedure; Vibration acceleration (RMS or peak acceleration value); At permanent location (S) IW/L14/03/02 based on ISO 16063-21:2003
10 Machine vibration meters
with a transducer of mass up to 300 g
Calibration — Vibration acceleration
0,1 ms⁻² to 400 ms⁻² in the frequency range: — 10 Hz · CMC 1,3 % 0,1 ms⁻² to 400 ms⁻² in the frequency range: — 12,5 Hz to 16 Hz · CMC 1,2 % 0,1 ms⁻² to 400 ms⁻² in the frequency range: — 20 Hz to 200 Hz · CMC 1,1 % 0,1 ms⁻² to 400 ms⁻² in the frequency range: — 250 Hz to 4 kHz · CMC 1,0 %
Vibration acceleration
Internal procedure; Determination of meter indication errors by the mechanical method; At permanent location (S) IW/L14/03/03 based on ISO 16063-21:2003
11 Vibration transducers
with a piezoelectric vibration transducer of mass up to 300 g
Calibration — Vibration transducer sensitivity
0,1 pCm⁻¹s² to 120 pCm⁻¹s² and 0,1 mVm⁻¹s² to 120 mVm⁻¹s² in the frequency range — 10 Hz to 16 Hz · CMC 1,3 % 0,1 pCm⁻¹s² to 120 pCm⁻¹s² and 0,1 mVm⁻¹s² to 120 mVm⁻¹s² in the frequency range — 20 Hz to 1 kHz · CMC 1,2 % 0,1 pCm⁻¹s² to 120 pCm⁻¹s² and 0,1 mVm⁻¹s² to 120 mVm⁻¹s² in the frequency range — 1,25 kHz to 4 kHz · CMC 1,4 %
Vibration transducer sensitivity
Internal procedure; Sensitivity of the vibration transducer / set; At permanent location (S) IW/L14/03/01 based on ISO 16063-21:2003
12 Optical indicators
MOP 02/20
Calibration — Length
-20 µm to 20 µm · CMC 0,09 µm
Length
Internal procedure; At permanent location (S) and outside of it (P) IW/7W11/18/01
13 Abbe horizontal length measuring machines Calibration — Length
0 mm to 100 mm · CMC ext. 0,5 µm; int. 1,0 µm
Length
Internal procedure; At permanent location (S) and outside of it (P) IW/7W11/27/02
14 Caliper depth gauges Calibration — Length
0 mm do 300 mm · CMC 12 µm 0 mm to 600 mm · CMC 18 µm
Length
Internal procedure; At permanent location (S) IW/L11/01/02
15 Gauge blocks of classes 0, 1, 2 Calibration — Length
0,5 mm to 100 mm · CMC Q[0,06; 1,1 · L] µm
Length
Internal procedure; At permanent location (S) IW/L11/11/01
16 Tape measures Calibration — Length
0 mm to 5 m · CMC Q[0,09; 0,018 · L] mm 0 m to 25 m · CMC Q[0,08; 0,022 · L] mm
Length
Internal procedure; At permanent location (S) IW/L11/38/02
17 Calipers Calibration — Length
0 mm do 150 mm · CMC 9 µm 0 mm do 250 mm · CMC 11 µm 0 mm do 400 mm · CMC 14 µm 0 mm do 630 mm · CMC 19 µm 0 mm to 1000 mm · CMC 28 µm
Length
Internal procedure; At permanent location (S) IW/7W11/01/01
18 Dial thickness gauges Calibration — Length
scale interval 0,01 mm; resolution 0,001 mm — 0 mm to 10 mm · CMC 0,8 µm scale interval 0,01 mm; resolution 0,001 mm — 0 mm to 50 mm · CMC 1,5 µm scale interval 0,1 mm; resolution 0,01 mm — 0 mm to 50 mm · CMC 5,8 µm
Length
Internal procedure; At permanent location (S) IW/L11/41/01
19 External micrometers Calibration — Length
0 mm to 50 mm · CMC 1,1 µm 50 mm do 100 mm · CMC 1,7 µm 100 mm do 150 mm · CMC 2,3 µm 150 mm do 200 mm · CMC 3,0 µm 200 mm do 250 mm · CMC 3,6 µm 250 mm do 300 mm · CMC 4,3 µm 300 mm do 400 mm · CMC 4,8 µm 400 mm do 500 mm · CMC 6,2 µm 500 mm do 600 mm · CMC 7,6 µm
Length
Internal procedure; At permanent location (S) IW/L11/02/01
20 Setting rings
using bow attachments
Calibration — Length
12 mm to 34 mm · CMC 1,6 µm 35 mm to 99 mm · CMC 1,7 µm 100 mm to 199 mm · CMC 1,9 µm 200 mm to 300 mm · CMC 2,6 µm
Length
Internal procedure; At permanent location (S) IW/L11/48/01
21 Setting rings
using a measuring head
Calibration — Length
3 mm to 90 mm · CMC 2,2 µm
Length
Internal procedure; At permanent location (S) IW/L11/48/05
22 Optical parallels
- deviation of the central length from the nominal length
Calibration — Length
12 mm to 80 mm · CMC 0,5 µm
Length
Internal procedure; At permanent location (S) IW/L11/16/02
23 Special caliper instruments –
Digital weld gauges
Calibration — Length
measurement of welds on a plane — 0 mm to 10 mm · CMC 8 µm measurement of welds in corners — 0 mm to 10 mm · CMC 18 µm
Length
Internal procedure; At permanent location (S) IW/7W11/01/05
24 Analogue weld gauges Calibration — Length
measurement of welds on a plane — 0 mm to 10 mm · CMC 0,06 mm measurement of welds in corners — 0 mm to 10 mm · CMC 0,07 mm
Length
Internal procedure; At permanent location (S) IW/7W11/01/05
25 Plug gauges Calibration — Length
1 mm to 50 mm · CMC 0,8 µm 50 mm to 100 mm · CMC 1,0 µm
Length
Internal procedure; At permanent location (S) IW/L11/17/02
26 Feeler gauges Calibration — Length
0,03 mm to 2 mm · CMC 1,0 µm
Length
Internal procedure; At permanent location (S) IW/L11/17/03
27 Measuring wires
- for threads
Calibration — Length
0,170 mm to 6,350 mm · CMC 0,40 µm
Length
Internal procedure; At permanent location (S) IW/7W11/21/01
28 Measuring wires
- for holes
Calibration — Length
1,0 mm to 20,0 mm · CMC 0,34 µm
Length
Internal procedure; At permanent location (S) IW/7W11/21/02
29 Height gauges for measuring vehicle wheel height Calibration — Length
0 mm to 1000 mm · CMC 0,5 mm
Length
Internal procedure; At permanent location (S) IW/L11/01/04
30 Caliper height gauges Calibration — Length
0 mm do 400 mm · CMC 14 µm 0 mm do 630 mm · CMC 19 µm 0 mm to 1000 mm · CMC 28 µm
Length
Internal procedure; At permanent location (S) IW/L11/01/03
31 Digital universal bevel protractors Calibration — Angle
360° · CMC 1,2′
Angle
Internal procedure; At permanent location (S) IW/L11/03/01
32 Analogue universal bevel protractors Calibration — Angle
4 x 90° · CMC 3,0′
Angle
Internal procedure; At permanent location (S) IW/L11/03/01
33 90 ° try squares Calibration — Angle
flatness deviation — length of the longer arm from 40 mm to 500 mm · CMC 2,8 µm straightness deviation — length of the longer arm from 40 mm to 500 mm · CMC 1,7 µm parallelism deviation — length of the longer arm from 40 mm to 500 mm · CMC 2,7 µm squareness deviation — length of the longer arm from 40 mm to 500 mm · CMC 1,7 µm
Angle
Internal procedure; At permanent location (S) IW/L11/07/01
34 90 ° try squares Calibration — Angle
flatness deviation — length of the longer arm above 500 mm to 1000 mm · CMC 3,2 µm straightness deviation — length of the longer arm above 500 mm to 1000 mm · CMC 3,2 µm parallelism deviation — length of the longer arm above 500 mm to 1000 mm · CMC 2,9 µm squareness deviation — length of the longer arm above 500 mm to 1000 mm · CMC 15 µm
Angle
Internal procedure; At permanent location (S) IW/L11/47/01
35 Kusznikow angle gauge blocks
Wringing angle gauge blocks
Calibration — Angle
0° to 180° · CMC 4,0″
Angle
Internal procedure; At permanent location (S) IW/L11/15/01
36 Builders' spirit levels Calibration — Angle
length up to 200 cm · CMC 0,2 mm (zero setting error)
Angle
Internal procedure; At permanent location (S) IW/7W11/09/03
37 Optical flats
- flatness deviation
Calibration — Angle
diameter — 40 mm to 100 mm · CMC 0,04 µm
Angle
Internal procedure; At permanent location (S) IW/L11/16/01
38 Optical parallels Calibration — Angle
flatness deviation — 12 mm to 80 mm · CMC 0,06 µm parallelism deviation — 12 mm to 80 mm · CMC 0,16 µm
Angle
Internal procedure; At permanent location (S) IW/L11/16/02
39 Surface straight edges
calibrated with a differential level
- flatness deviation
Calibration — Angle
length — up to 400 mm · CMC 3,2 µm length — 400 mm to 630 mm · CMC 4,5 µm length — 630 mm to 1000 mm · CMC 5,5 µm length — 1000 mm to 2500 mm · CMC 8,9 µm
Angle
Internal procedure; At permanent location (S) and outside of it (P) IW/7W11/33/01
40 Surface plates
calibrated with a differential level
- flatness deviation
Calibration — Angle
size — 250 mm x 250 mm · CMC 2,6 µm length of the longer side — 250 mm to 400 mm · CMC 3,2 µm length of the longer side — 400 mm to 800 mm · CMC 4,9 µm length of the longer side — 800 mm to 1200 mm · CMC 6,1 µm length of the longer side — 1200 mm to 2500 mm · CMC 8,9 µm
Angle
Internal procedure; At permanent location (S) and outside of it (P) IW/L11/33/02
41 Testing machines Calibration — Force
tension — 0,1 N to 200 kN · CMC 0,12 % proving devices cl. 0.5 tension — 0,1 N to 200 kN · CMC 0,24 % proving devices cl. 1 compression — 0,1 N to 3 MN · CMC 0,12 % proving devices cl. 0.5 compression — 0,1 N to 3 MN · CMC 0,24 % proving devices cl. 1
Force
Internal procedure; Outside of permanent location (P) IW/L13/01/01 based on PN-EN ISO 7500-1:2018-05
42 Force gauges Calibration — Force
0,1 N to 5 kN · CMC 0,025 % 200 N to 100 kN · CMC 0,06 %
Force
Internal procedure; At permanent location (S) IW/L13/03/01 IW/L13/03/02
43 Torque wrenches
Torque screwdrivers
Calibration — Torque
torque wrenches — 0,04 Nm to 2500 Nm · CMC 0,3 % torque screwdrivers — 0,04 Nm to 25 Nm · CMC 0,3 %
Torque
Internal procedure; At permanent location (S) IW/L13/06/01 based on PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03
44 Torque transducers Calibration — Torque
0,04 Nm to 1500 Nm · CMC 0,2 %
Torque
Internal procedure; At permanent location (S) IW/L13/06/02
45 Charpy pendulum impact testing machines Calibration — Impact strength
1 J to 300 J · CMC 0,55 Kₙ
Impact strength
Internal procedure; At permanent location (S) and outside of it (P) IW/L13/04/01 based on PN-EN ISO 148-2:2017-02
46 Brinell hardness testers Calibration — Hardness
hardness — HBW2,5/62,5 · CMC 2,2 % hardness — HBW2,5/187,5 · CMC 2,2 % hardness — HBW5/250 · CMC 2,2 % hardness — HBW5/750 · CMC 2,2 % hardness — HBW10/500 · CMC 2,2 % hardness — HBW10/1000 · CMC 2,2 % hardness — HBW10/3000 · CMC 2,2 % force — 1839 N to 29420 N · CMC 0,24 % proving device cl. 1 length — 0 mm to 1 mm · CMC 0,0005 mm length — 1 mm to 7 mm · CMC 0,005 mm
Hardness
Internal procedure; At permanent location (S) and outside of it (P) IW/L13/02/02 based on PN-EN ISO 6506-2:2019-10
47 Rockwell hardness testers Calibration — Hardness
hardness — 45 HRA to 95 HRA · CMC 0,6 HRA hardness — 60 HRB to 100 HRB · CMC 0,7 HRB hardness — 10 HRC to 70 HRC · CMC 0,6 HRC force — 29,42 N to 1471 N · CMC 0,24 % proving device cl. 1
Hardness
Internal procedure; At permanent location (S) and outside of it (P) IW/L13/02/01 based on PN-EN ISO 6508-2:2024-06
48 Vickers hardness testers Calibration — Hardness
hardness — HV3; HV5; HV10; HV30; HV50; HV100 · CMC 2,5 % force — 29,42 N to 980 N · CMC 0,24 % proving device cl. 1 length — 0 mm to 1 mm · CMC 0,0005 mm
Hardness
Internal procedure; At permanent location (S) and outside of it (P) IW/L13/02/03 based on PN-EN ISO 6507-2:2018-05
49 Hygrometers
Thermohygrometers for measuring the relative humidity of air
Electronic psychrometers
Calibration — Relative humidity
50 % to 80 % at t = 10 °C · CMC 0,8 % for 50 % 50 % to 80 % at t = 10 °C · CMC 1,2 % for 80 % 20 % to 80 % at t = 23 °C · CMC 0,5 % for 20 % 20 % to 80 % at t = 23 °C · CMC 0,9 % for 80 % 20 % to 60 % at t = 35 °C · CMC 0,5 % for 20 % 20 % to 60 % at t = 35 °C · CMC 0,9 % for 60 %
Relative humidity
Internal procedure; At permanent location (S) IW/L23/08/01
50 Absolute pressure
Bourdon tube and electronic pressure gauges including barometers
Calibration — Pressure
500 hPa to 1100 hPa · CMC 0,2 hPa
Pressure
Internal procedure; At permanent location (S) IW/L23/06/01
51 Electrical thermometers Calibration — Temperature (electrical thermometry)
- 25 °C to 100 °C · CMC 0,13 °C 100 °C to 300 °C · CMC 0,22 °C 300 °C to 520 °C · CMC 0,41 °C
Temperature (electrical thermometry)
Internal procedure; At permanent location (S) IW/L23/01/01
52 Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry)
-10 °C to 70 °C · CMC 0,1 °C
Temperature (electrical thermometry)
Internal procedure; Performed in a climatic chamber; At permanent location (S) IW/L23/08/01
53 Piston burettes Calibration — Volume
1000 µl to 2500 µl · CMC 2,0 µl 2500 µl to 5000 µl · CMC 6,5 µl 5000 µl to 10000 µl · CMC 12 µl 10000 µl to 12500 µl · CMC 15 µl 12500 µl to 25000 µl · CMC 31 µl 25000 µl to 50000 µl · CMC 58 µl
Volume
Internal procedure; At permanent location (S) IW/L21/01/02 based on PN-EN ISO 8655-6:2022-11
54 Measuring cylinders of classes A and B Calibration — Volume
5 ml · CMC 0,015 ml 10 ml · CMC 0,026 ml 25 ml · CMC 0,060 ml 50 ml · CMC 0,11 ml 100 ml · CMC 0,20 ml 250 ml · CMC 0,35 ml 500 ml · CMC 0,70 ml 1000 ml · CMC 1,1 ml 2000 ml · CMC 2 ml
Volume
Internal procedure; At permanent location (S) IW/L21/01/01 based on PN-EN ISO 4787:2022-06
55 Piston dispensers Calibration — Volume
1000 µl to 5000 µl · CMC 10 µl 5000 µl to 10000 µl · CMC 27 µl 10000 µl to 20000 µl · CMC 49 µl 20000 µl to 30000 µl · CMC 63 µl 30000 µl to 40000 µl · CMC 67 µl 40000 µl to 50000 µl · CMC 87 µl
Volume
Internal procedure; At permanent location (S) IW/L21/01/02 based on PN-EN ISO 8655-6:2022-11
56 One-mark glass volumetric flasks of classes A and B Calibration — Volume
1 ml · CMC 0,0051 ml 2 ml · CMC 0,0051 ml 5 ml · CMC 0,0054 ml 10 ml · CMC 0,0056 ml 25 ml · CMC 0,0085 ml 50 ml · CMC 0,017 ml 100 ml · CMC 0,027 ml 200 ml · CMC 0,051 ml 250 ml · CMC 0,052 ml 500 ml · CMC 0,073 ml 1000 ml · CMC 0,17 ml 2000 ml · CMC 0,19 ml
Volume
Internal procedure; At permanent location (S) IW/L21/01/01 based on PN-EN ISO 4787:2022-06
57 Single-channel piston pipettes Calibration — Volume
1 µl to 10 µl · CMC 0,030 µl 10 µl to 20 µl · CMC 0,040 µl 20 µl to 50 µl · CMC 0,050 µl 50 µl to 100 µl · CMC 0,15 µl 100 µl to 200 µl · CMC 0,28 µl 200 µl to 500 µl · CMC 0,71 µl 500 µl to 1000 µl · CMC 1,6 µl 1000 µl to 2500 µl · CMC 4,0 µl 2500 µl to 5000 µl · CMC 7,3 µl 5000 µl to 10000 µl · CMC 15 µl
Volume
Internal procedure; At permanent location (S) IW/L21/01/02 based on PN-EN ISO 8655-6:2022-11
58 Multi-channel piston pipettes Calibration — Volume
10 µl to 20 µl · CMC 0,050 µl 20 µl to 200 µl · CMC 0,30 µl 200 µl to 300 µl · CMC 0,50 µl 300 µl to 600 µl · CMC 1,8 µl 600 µl to 1200 µl · CMC 2,5 µl
Volume
Internal procedure; At permanent location (S) IW/L21/08/01 based on PN-EN ISO 8655-6:2022-11
59 Reference sources
Digital voltmeters
Analogue voltmeters
Multimeters
Calibrators
Calibration — DC voltage
1V; 1,018 V · CMC 0,0003 % 10 V · CMC 0,00015 % 10 µV to 10 mV · CMC 0,0015 % 10 mV to 100 mV · CMC 0,0012 % 100 mV to 1 V · CMC 0,0005 % 1 V to 10 V · CMC 0,0004 % 10 V to 100 V · CMC 0,0006 % 100 V to 1000 V · CMC 0,0006 % 1000 V to 5000 V · CMC 0,01 %
DC voltage
Internal procedure; Direct or indirect method; At permanent location (S) IW/L31/01/01 IW/L31/01/05 IW/L31/01/06
60 Digital ammeters
Analogue ammeters
Multimeters
Calibrators
Clamp meters
Calibration — DC current
1 µA to 100 µA · CMC 0,01 % 100 µA to 100 mA · CMC 0,005 % 100 mA to 1 A · CMC 0,011 % 1 A to 20 A · CMC 0,02 % 20 A to 1000 A · CMC 0,25 %
DC current
Internal procedure; Direct or indirect method; At permanent location (S) IW/L31/01/01 IW/L31/01/05 IW/L31/01/06 IW/L31/01/07
61 Digital voltmeters
Analogue voltmeters
Multimeters
Calibrators
Calibration — AC voltage
10 Hz to 30 Hz — 100 µV to 100 mV · CMC 2,6 ∙ 10⁻⁴ ∙ U + 5 µV 10 Hz to 30 Hz — 100 mV to 100 V · CMC 0,013 % 30 Hz to 300 Hz — 100 µV to 100 mV · CMC 2,1 ∙ 10⁻⁴ ∙ U + 5 µV 30 Hz to 300 Hz — 100 mV to 10 V · CMC 0,0075 % 30 Hz to 300 Hz — 10 V to 100 V · CMC 0,009 % 45 Hz to 300 Hz — 100 V to 1000 V · CMC 0,02 % 45 Hz to 300 Hz — 1000 V to 3000 V · CMC 0,6 % 300 Hz to 10 kHz — 100 µV to 100 mV · CMC 2,0 ∙ 10⁻⁴ ∙ U + 5 µV 300 Hz to 10 kHz — 100 mV to 10 V · CMC 0,006 % 300 Hz to 10 kHz — 10 V to 100 V · CMC 0,007 % 300 Hz to 10 kHz — 100 V to 1000 V · CMC 0,015 % 10 kHz to 30 kHz — 100 µV to 100 mV · CMC 3,0 ∙ 10⁻⁴ ∙ U + 5 µV 10 kHz to 30 kHz — 100 mV to 10 V · CMC 0,007 % 10 kHz to 30 kHz — 10 V to 100 V · CMC 0,009 % 10 kHz to 30 kHz — 100 V to 1000 V · CMC 0,02 % 30 kHz to 100 kHz — 100 µV to 100 mV · CMC 6,0 ∙ 10⁻⁴ ∙ U + 5 µV 30 kHz to 100 kHz — 100 mV to 10 V · CMC 0,012 % 30 kHz to 100 kHz — 10 V to 100 V · CMC 0,02 % 30 kHz to 100 kHz — 100 V to 750 V · CMC 0,1 % 100 kHz to 200 kHz — 100 µV to 100 mV · CMC 1.3 ∙ 10⁻³ ∙ U + 10 µV 100 kHz to 200 kHz — 100 mV to 10 V · CMC 0,04 % 100 kHz to 200 kHz — 10 V to 100 V · CMC 0,06 % 200 kHz to 300 kHz — 100 µV to 100 mV · CMC 1,3 ∙ 10⁻³ ∙ U + 10 µV 200 kHz to 300 kHz — 100 mV to 10 V · CMC 0,035 % 300 kHz to 1 MHz — 100 µV to 100 mV · CMC 2,9 ∙ 10⁻³ ∙ U + 10 µV 300 kHz to 1 MHz — 100 mV to 10 V · CMC 0,06 %
AC voltage
Internal procedure; Direct or indirect method; At permanent location (S) IW/L31/01/01 IW/L31/01/05 IW/L31/01/06
62 Digital ammeters
Analogue ammeters
Multimeters
Calibrators
Residual current device testers
Calibration — AC current
10 kHz to 1 kHz — 10 µA to 100 µA · CMC 0,025 % 10 kHz to 1 kHz — 100 µA to 100 mA · CMC 0,02 % 10 kHz to 1 kHz — 100 mA to 1 A · CMC 0,038 % 10 kHz to 1 kHz — 1 A to 20 A · CMC 0,045 % 1 kHz to 5 kHz — (10 µA to 100) µA · CMC 0,045 % 1 kHz to 5 kHz — 100 µA to 100 mA · CMC 0,035 % 1 kHz to 5 kHz — 100 mA to 1 A · CMC 0,06 % 1 kHz to 5 kHz — 1 A to 20 A · CMC 0,1 % 5 kHz to 10 kHz — 1 A to 10 A · CMC 0,21 % 10 kHz to 20 kHz — 1 A to 10 A · CMC 0,82 %
AC current
Internal procedure; Direct or indirect method; At permanent location (S) IW/L31/01/01 IW/L31/01/05 IW/L31/01/06 IW/L31/01/07
63 Clamp meters Calibration — AC current
50 Hz — 3,2 A to 1000 A · CMC 0,56 %
AC current
Internal procedure IW/L31/01/07
64 Analogue ohmmeters
Digital ohmmeters
Resistance calibrators
Insulation resistance meters
Loop impedance meters
Earth resistance meters
Bridges
Fixed resistors
Variable resistors
Multimeters
Shunts
Calibration — DC resistance
0,00001 Ω to 0,0001 Ω · CMC 0,02 % 0,001 Ω to 1 Ω · CMC 0,006 % 1 Ω to 10 Ω · CMC 0,0015 % 10 Ω to 100 Ω · CMC 0,0010 % 100 Ω to 100 kΩ · CMC 0,0006 % 100 kΩ to 1 MΩ · CMC 0,0018 % 1 MΩ to 10 MΩ · CMC 0,0055 % 10 MΩ to 100 MΩ · CMC 0,0046 % 100 MΩ to 1000 MΩ · CMC 0,07 % 1 GΩ to 100 GΩ · CMC 0,1 %
DC resistance
Internal procedure; Direct or indirect method; At permanent location (S) IW/L31/01/01 IW/L31/01/05 IW/L31/01/06 IW/L31/04/01 IW/L31/05/01
65 RLC bridges (meters)
Fixed resistors
Variable resistors
Calibration — AC resistance
45 kHz to 55 kHz — 0,1 Ω to 1 Ω · CMC 0,3 % 45 kHz to 55 kHz — 1 Ω to 10 Ω · CMC 0,08 % 45 kHz to 55 kHz — 10 Ω to 100 kΩ · CMC 0,06 % 45 kHz to 55 kHz — 100 kΩ to 1 MΩ · CMC 0,1 % 1 kHz — 0,1 Ω to 1 Ω · CMC 0,13 % 1 kHz — 1 Ω to 100 kΩ · CMC 0,025 % 1 kHz — 100 kΩ to 1 MΩ · CMC 0,035 %
AC resistance
Internal procedure; At permanent location (S) IW/L31/05/06
66 Loop impedance meters Calibration — AC resistance
50 Hz — 0,1 Ω to 1000 Ω · CMC 1,0 ∙ 10⁻³ ∙ R + 0,01 Ω
AC resistance
Internal procedure; Direct method; At permanent location (S) IW/L31/04/01
67 Variable standard inductors
Fixed standard inductors
Bridges
Inductance meters
Calibration — Inductance
1 kHz — 1 H to 10 H · CMC 0,05 % 1 kHz — 1 mH to 1 H · CMC 0,03 % 1 kHz — 300 µH to 1 mH · CMC 0,07 % 1 kHz — 100 µH to 300 µH · CMC 0,1 % 1 kHz — 20 µH to 100 µH · CMC 0,2 % 1 kHz — 2 µH to 20 µH · CMC 2% 1 kHz — 1 µH to 2 µH · CMC 6% 45 Hz to 55 Hz — 100 mH to 10 H · CMC 0,07 % 45 Hz to 55 Hz — 10 mH to 100 mH · CMC 0,12 % 45 Hz to 55 Hz — 3 mH to 10 mH · CMC 0,2 % 45 Hz to 55 Hz — 2 mH to 3 mH · CMC 0,3 % 45 Hz to 55 Hz — 0,3 mH to 2 mH · CMC 0,6 % 400 Hz — 10 mH to 10 H · CMC 0,06 % 400 Hz — 1 mH to 10 mH · CMC 0,08 % 10 kHz — 500 µH to 1 H · CMC 0,07 % 10 kHz — 50 µH to 500 µH · CMC 0,1 %
Inductance
Internal procedure; At permanent location (S) IW/L31/05/05 IW/L31/05/06
68 Variable standard capacitors
Fixed standard capacitors
Bridges
Capacitance meters
Calibration — Capacitance
1 kHz — 10 pF to 100 pF · CMC 0,03 % 1 kHz — 100 pF to 1 µF · CMC 0,025 % 1 kHz — 1 µF to 10 µF · CMC 0,05 % 1 kHz — 100 pF · CMC 0,015 % 1 kHz — 200 pF · CMC 0,015 % 1 kHz — 300 pF · CMC 0,015 % 1 kHz — 400 pF · CMC 0,015 % 1 kHz — 1000 pF · CMC 0,015 % 1 kHz — 3000 pF · CMC 0,015 % 1 kHz — 4000 pF · CMC 0,015 % 1 kHz — 0,01 µF · CMC 0,02 % 1 kHz — 0,02 µF · CMC 0,02 % 1 kHz — 0,03 µF · CMC 0,02 % 1 kHz — 0,04 µF · CMC 0,02 % 1 kHz — 1 µF · CMC 0,02 % 1 kHz — 10 pF · CMC 0,015 % 1 kHz — 20 pF · CMC 0,015 % 1 kHz — 30 pF · CMC 0,015 % 1 kHz — 40 pF · CMC 0,015 %
Capacitance
Internal procedure; At permanent location (S) IW/L31/05/05 IW/L31/05/06
69 AC active electrical energy meters
AC reactive electrical energy meters
Energy meter test equipment
Calibration — Energy
45 Hz to 65 Hz; 30 V to 520 V; 0,02 A to 120 A; cosφ and sinφ of inductive or capacitive character) — cosφ ± 1 · CMC 0,012 % 45 Hz to 65 Hz; 30 V to 520 V; 0,02 A to 120 A; cosφ and sinφ of inductive or capacitive character) — cosφ ± 0,8 · CMC 0,012 % 45 Hz to 65 Hz; 30 V to 520 V; 0,02 A to 120 A; cosφ and sinφ of inductive or capacitive character) — cosφ ± 0,5 · CMC 0,012 % 45 Hz to 65 Hz; 30 V to 520 V; 0,02 A to 120 A; cosφ and sinφ of inductive or capacitive character) — cosφ ± 0,25 · CMC 0,024 % 45 Hz to 65 Hz; 30 V to 520 V; 0,02 A to 120 A; cosφ and sinφ of inductive or capacitive character) — sinφ ± 1 · CMC 0,012 % 45 Hz to 65 Hz; 30 V to 520 V; 0,02 A to 120 A; cosφ and sinφ of inductive or capacitive character) — sinφ ± 0,8 · CMC 0,012 % 45 Hz to 65 Hz; 30 V to 520 V; 0,02 A to 120 A; cosφ and sinφ of inductive or capacitive character) — sinφ ± 0,5 · CMC 0,012 % 45 Hz to 65 Hz; 30 V to 520 V; 0,02 A to 120 A; cosφ and sinφ of inductive or capacitive character) — sinφ ± 0,25 · CMC 0,024 % 45 Hz to 65 Hz; 30 V to 520 V; 0,001 A to 0,020 A; cosφ and sinφ of inductive or capacitive character — cosφ ± 1 · CMC 0,024 % 45 Hz to 65 Hz; 30 V to 520 V; 0,001 A to 0,020 A; cosφ and sinφ of inductive or capacitive character — cosφ ± 0,8 · CMC 0,024 % 45 Hz to 65 Hz; 30 V to 520 V; 0,001 A to 0,020 A; cosφ and sinφ of inductive or capacitive character — cosφ ± 0,5 · CMC 0,024 % 45 Hz to 65 Hz; 30 V to 520 V; 0,001 A to 0,020 A; cosφ and sinφ of inductive or capacitive character — cosφ ± 0,25 · CMC 0,046 % 45 Hz to 65 Hz; 30 V to 520 V; 0,001 A to 0,020 A; cosφ and sinφ of inductive or capacitive character — sinφ ± 1 · CMC 0,024 % 45 Hz to 65 Hz; 30 V to 520 V; 0,001 A to 0,020 A; cosφ and sinφ of inductive or capacitive character — sinφ ± 0,8 · CMC 0,024 % 45 Hz to 65 Hz; 30 V to 520 V; 0,001 A to 0,020 A; cosφ and sinφ of inductive or capacitive character — sinφ ± 0,5 · CMC 0,024 % 45 Hz to 65 Hz; 30 V to 520 V; 0,001 A to 0,020 A; cosφ and sinφ of inductive or capacitive character — sinφ ± 0,25 · CMC 0,046 %
Energy
Internal procedure; Reference meter method; At permanent location (S) and outside of it (P) IW/L31/02/01 IW/L31/02/02
70 DC energy meters Calibration — Energy
100 V to 5000 V — 1 % Iₙ to 10 % Iₙ · CMC 0,07 % 100 V to 5000 V — 10 % Iₙ to 50 % Iₙ · CMC 0,05 % 100 V to 5000 V — 50 % Iₙ to 100 % Iₙ · CMC 0,03 %
Energy
Internal procedure; Technical method; At permanent location (S) IW/L31/01/09
71 Power meters Calibration — AC power
50 Hz; 30 V to 520 V; 0,1 A to 100 A; 0,3 W to 52 kW; 0,3 Var to 52 kVar; cosφ and sinφ of inductive or capacitive character — cosφ ± <1 ÷ 0,5> · CMC 0,012 % 50 Hz; 30 V to 520 V; 0,1 A to 100 A; 0,3 W to 52 kW; 0,3 Var to 52 kVar; cosφ and sinφ of inductive or capacitive character — cosφ ± (0,5 ÷ 0) · CMC 0,012 % / (2cosφ) 50 Hz; 30 V to 520 V; 0,1 A to 100 A; 0,3 W to 52 kW; 0,3 Var to 52 kVar; cosφ and sinφ of inductive or capacitive character — sinφ ± <1 ÷ 0,5> · CMC 0,012 % 50 Hz; 30 V to 520 V; 0,1 A to 100 A; 0,3 W to 52 kW; 0,3 Var to 52 kVar; cosφ and sinφ of inductive or capacitive character — sinφ ± (0,5 ÷ 0) · CMC 0,012% / (2sinφ)
AC power
Internal procedure; Direct method; At permanent location (S) and outside of it (P) IW/L31/01/05 IW/L31/01/06
72 Digital timing comparators Calibration — Time (time interval)
± 999,0 s/d · CMC 0,6 · Δ₁ for Δ₁ ≥ 0,1 s/d ± 19,0 s/d · CMC 0,8 · Δ₁ for Δ₁ < 0,1 s/d
Time (time interval)
Internal procedure; At permanent location (S) IW/L31/03/03
73 Period meters Calibration — Time (time interval)
5 ns to 10 µs · CMC 5·10⁻¹⁰ · T 10 µs to 10 s · CMC 5·10⁻¹⁰ · T
Time (time interval)
Internal procedure; At permanent location (S) IW/L31/03/04
74 Time interval meters Calibration — Time (time interval)
1 µs to 1000 s · CMC 5 ns + 5·10⁻¹⁰ · τ
Time (time interval)
Internal procedure; At permanent location (S) IW/L31/03/04
75 Electronic stopwatches Calibration — Time (time interval)
0 h to 24 h · CMC 0,003 s + 1,8 ·10⁻⁷ · τ
Time (time interval)
Internal procedure; At permanent location (S) IW/L31/03/02
76 Mechanical stopwatches Calibration — Time (time interval)
0 h to 1 h · CMC 0,07 s + 2,0 ·10⁻⁵ · τ
Time (time interval)
Internal procedure; At permanent location (S) IW/L31/03/01
77 Frequency generators Calibration — Frequency
0,1 Hz to 3 GHz · CMC 2·10⁻⁵ Hz + 5·10⁻¹⁰ · f
Frequency
Internal procedure; At permanent location (S) IW/L31/03/05
78 Digital frequency meters
- frequency counters
Calibration — Frequency
sinusoidal waveform — 100 kHz to 1,9 GHz · CMC 5·10⁻¹⁰ · f square waveform — 0,1 Hz to 100 kHz · CMC 5·10⁻¹⁰ · f
Frequency
Internal procedure; At permanent location (S) IW/L31/03/04
79 Tachometers Calibration — Frequency
2,00 rpm to 99,99 rpm · CMC 0,01 rpm 100,0 rpm to 9999,9 rpm · CMC 0,1 rpm 1000 rpm to 99999 rpm · CMC 1 rpm
Frequency
Internal procedure; At permanent location (S) IW/L32/02/01
80 pH meters Calibration — pH
pH — 0 to 14 · CMC 0,003 DC voltage — -1400 mV to 1400 mV · CMC 0,3 mV
pH
Internal procedure; Electrical method; At permanent location (S) IW/L42/03/02
81 pH meters Calibration — pH
pH — 1,00 to 8,00 · CMC 0,03 pH — 8,01 to 11,00 · CMC 0,04 pH — 11,01 to 13,00 · CMC 0,3
pH
Internal procedure; Method using reference materials; At permanent location (S) IW/L42/12/01
82 pH electrodes Calibration — pH
40 mV to 80 mV · CMC 0,4 mV
pH
Internal procedure; Measurement of the characteristic slope; At permanent location (S) IW/L42/12/01
83 Conductivity meters Calibration — Specific electrical conductivity (conductometry)
200 mS/cm · CMC 0,46 % 20,00 mS/cm to 180,00 mS/cm · CMC 0,20 % 2,000 mS/cm to 18,000 mS/cm · CMC 0,005 % 0,2000 mS/cm to 1,8000 mS/cm · CMC 0,0005 % 20,00 µS/cm to 180,00 µS/cm · CMC 0,04 % 2,000 µS/cm to 18,000 µS/cm · CMC 0,003 % 0,100 µS/cm to 1,800 µS/cm · CMC 0,002 %
Specific electrical conductivity (conductometry)
Internal procedure; Electrical method; At permanent location (S) IW/L42/10/01
84 Conductivity meters Calibration — Specific electrical conductivity (conductometry)
0,014 S/m to 0,070 S/m · CMC 0,4 % 0,070 S/m to 11,5 S/m · CMC 0,2 %
Specific electrical conductivity (conductometry)
Internal procedure; Method using reference materials; At permanent location (S) IW/L42/13/02
85 Conductivity sensors Calibration — Specific electrical conductivity (conductometry)
0,1 cm⁻¹ to 2,0 cm⁻¹ · CMC 0,7 %
Specific electrical conductivity (conductometry)
Internal procedure; Measurement of K – the conductivity cell constant; At permanent location (S) IW/L42/13/01
86 Oscillating density meters Calibration — Density (liquid)
T = 20 °C — 0,6 g/cm³ to 1,6 g/cm³ · CMC 5 · 10⁻⁵ g/cm³; 2 · 10⁻⁵ g/cm³
Density (liquid)
Internal procedure; At permanent location (S) and outside of it (P) IW/L42/06/01
87 Refractometers Calibration — Refractive index
refractive index of liquid standards — 1,33 to 1,66 · CMC 0,00003
Refractive index
Internal procedure; At permanent location (S) and outside of it (P) IW/L42/04/01 IP/L42/14 based on OIML R 124:1997
88 Refractometers Calibration — Refractive index
refractive index of solid standards — 1,46 to 1,63 · CMC 0,0002 percentage sucrose content expressed as mass fraction — up to 70,0 % (m/m) · CMC 0,03 % (m/m)
Refractive index
Internal procedure; At permanent location (S) IW/L42/04/01 IP/L42/14 based on OIML R 124:1997
89 Spectrophotometers Calibration — Optical density of spectral transmittance
0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC Blank: 0,0364 · CMC 0,0035 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC Blank: 0,0384 · CMC 0,0035 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC Blank: 0,0418 · CMC 0,0035 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC Blank: 0,0460 · CMC 0,0035 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 20 mg/l: 0,2528 · CMC 0,0039 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 20 mg/l: 0,1384 · CMC 0,0037 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 20 mg/l: 0,3344 · CMC 0,0039 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 20 mg/l: 0,3008 · CMC 0,0039 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 40 mg/l: 0,4551 · CMC 0,0047 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 40 mg/l: 0,2288 · CMC 0,0042 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 40 mg/l: 0,6077 · CMC 0,0047 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 40 mg/l: 0,5353 · CMC 0,0047 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 60 mg/l: 0,6774 · CMC 0,0051 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 60 mg/l: 0,3262 · CMC 0,0047 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 60 mg/l: 0,9060 · CMC 0,0052 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 60 mg/l: 0,7880 · CMC 0,0052 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 80 mg/l: 0,8876 · CMC 0,0059 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 80 mg/l: 0,4245 · CMC 0,0059 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 80 mg/l: 1,1942 · CMC 0,0059 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 80 mg/l: 1,0412 · CMC 0,0059 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 100 mg/l: 1,0979 · CMC 0,0078 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 100 mg/l: 0,5195 · CMC 0,0077 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 100 mg/l: 1,4851 · CMC 0,0078 0,03 to 1,50; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 100 mg/l: 1,2920 · CMC 0,0078
Optical density of spectral transmittance
Internal procedure; At permanent location (S) and outside of it (P) IW/L42/01/01
90 Spectrophotometers Calibration — Optical density of spectral transmittance
zakres widmowy 400 nm to 890 nm — 1,0 to 0,7 · CMC 0,0053 zakres widmowy 400 nm to 890 nm — 0,7 to 0,4 · CMC 0,0047 zakres widmowy 400 nm to 890 nm — 0,4 to 0,2 · CMC 0,0039 zakres widmowy 400 nm to 890 nm — 0,2 to 0,0 · CMC 0,0036
Optical density of spectral transmittance
Internal procedure; At permanent location (S) and outside of it (P) IW/L42/01/01
91 Achromatic standards Calibration — Optical density of spectral transmittance
zakres widmowy 235 nm to 326 nm — 0,0 to 0,5 · CMC 0,0039 zakres widmowy 235 nm to 326 nm — 0,5 to 1,0 · CMC 0,0049 zakres widmowy 235 nm to 326 nm — 1,0 to 1,5 · CMC 0,0065 zakres widmowy 326 nm to 900 nm — 0,0 to 0,5 · CMC 0,0036 zakres widmowy 326 nm to 900 nm — 0,5 to 1,0 · CMC 0,0047 zakres widmowy 326 nm to 900 nm — 1,0 to 1,5 · CMC 0,0063
Optical density of spectral transmittance
Internal procedure; At permanent location (S) IW/L42/02/01
92 Spectrophotometers Calibration — Spectral transmittance
0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC Blank: 0,9196 · CMC 0,0059 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC Blank: 0,9155 · CMC 0,0059 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC Blank: 0,9082 · CMC 0,0059 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC Blank: 0,8995 · CMC 0,0059 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 20 mg/l: 0,5588 · CMC 0,0051 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 20 mg/l: 0,7272 · CMC 0,0050 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 20 mg/l: 0,4630 · CMC 0,0051 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 20 mg/l: 0,5002 · CMC 0,0051 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 40 mg/l: 0,3507 · CMC 0,0049 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 40 mg/l: 0,5905 · CMC 0,0045 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 40 mg/l: 0,2468 · CMC 0,0049 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 40 mg/l: 0,2915 · CMC 0,0049 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 60 mg/l: 0,2102 · CMC 0,0045 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 60 mg/l: 0,4719 · CMC 0,0040 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 60 mg/l: 0,1242 · CMC 0,0046 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 60 mg/l: 0,1629 · CMC 0,0046 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 80 mg/l: 0,1295 · CMC 0,0042 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 80 mg/l: 0,3763 · CMC 0,0042 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 80 mg/l: 0,0639 · CMC 0,0042 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 80 mg/l: 0,0909 · CMC 0,0042 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 100 mg/l: 0,0798 · CMC 0,0040 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 100 mg/l: 0,3024 · CMC 0,0039 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 100 mg/l: 0,0327 · CMC 0,0040 0,92 to 0,03; wavelengths: 350 nm, 313 nm, 257 nm, 235 nm; Realized using liquid standards.; The values given are nominal values — PDC 100 mg/l: 0,0511 · CMC 0,0040
Spectral transmittance
Internal procedure; At permanent location (S) and outside of it (P) IW/L42/01/01
93 Spectrophotometers Calibration — Spectral transmittance
zakres widmowy 400 nm to 890 nm — 0,1 to 0,2 · CMC 0,0037 zakres widmowy 400 nm to 890 nm — 0,2 to 0,4 · CMC 0,0040 zakres widmowy 400 nm to 890 nm — 0,4 to 0,6 · CMC 0,0047 zakres widmowy 400 nm to 890 nm — 0,6 to 1,0 · CMC 0,0051
Spectral transmittance
Internal procedure; At permanent location (S) and outside of it (P) IW/L42/01/01
94 Achromatic standards Calibration — Spectral transmittance
zakres widmowy 235 nm to 326 nm — 0,03 to 0,1 · CMC 0,0023 zakres widmowy 235 nm to 326 nm — 0,1 to 0,3 · CMC 0,0045 zakres widmowy 235 nm to 326 nm — 0,3 to 1,0 · CMC 0,0074 zakres widmowy 326 nm to 900 nm — 0,03 to 0,1 · CMC 0,0022 zakres widmowy 326 nm to 900 nm — 0,1 to 0,3 · CMC 0,0044 zakres widmowy 326 nm to 900 nm — 0,3 to 1,0 · CMC 0,0073
Spectral transmittance
Internal procedure; At permanent location (S) IW/L42/02/01
95 Spectrophotometers Calibration — Spectral transmittance
wavelength (exit slit half-width 1 nm) — 277 nm to 886 nm · CMC 0,2 nm
Spectral transmittance
Internal procedure; At permanent location (S) and outside of it (P) IW/L42/01/01
96 Wavelength standards Calibration — Spectral transmittance
277 nm to 886 nm · CMC 0,25 nm
Spectral transmittance
Internal procedure; At permanent location (S) IW/L42/02/01
97 Lux meters Calibration — Illuminance
0,5 lx to 5 lx · CMC 2,5 % 5 lx to 1 · 10⁴ lx · CMC 2,3 %
Illuminance
Internal procedure; At permanent location (S) IW/L42/08/01
98 Photometric calibrators1) Calibration — Illuminance
85 lx to 115 lx · CMC 3,1 %
Illuminance
Internal procedure; At permanent location (S) IW/L42/11/01
99 Polarimeters Calibration — Angle of rotation of the plane of polarization of light
angle of rotation of the plane of polarization of light — -8,700° to 34,664° · CMC 0,002° angle of rotation of the plane of polarization of light — -25,0°Z to 100,0°Z · CMC 0,01°Z
Angle of rotation of the plane of polarization of light
Internal procedure; At permanent location (S) and outside of it (P) IW/L42/05/01 based on OIML R14:1995

Reference standards (95)

IP/L42/14
ISO 16063-21:2003
IW/7W11/01/01
IW/7W11/01/05
IW/7W11/09/03
IW/7W11/18/01
IW/7W11/21/01
IW/7W11/21/02
IW/7W11/27/02
IW/7W11/33/01
IW/L11/01/02
IW/L11/01/03
IW/L11/01/04
IW/L11/02/01
IW/L11/03/01
IW/L11/07/01
IW/L11/11/01
IW/L11/15/01
IW/L11/16/01
IW/L11/16/02
IW/L11/17/02
IW/L11/17/03
IW/L11/33/02
IW/L11/38/02
IW/L11/41/01
IW/L11/47/01
IW/L11/48/01
IW/L11/48/05
IW/L13/01/01
IW/L13/02/01
IW/L13/02/02
IW/L13/02/03
IW/L13/03/01
IW/L13/03/02
IW/L13/04/01
IW/L13/06/01
IW/L13/06/02
IW/L14/03/01
IW/L14/03/02
IW/L14/03/03
IW/L21/01/01
IW/L21/01/02
IW/L21/08/01
IW/L23/01/01
IW/L23/06/01
IW/L23/08/01
IW/L31/01/01
IW/L31/01/05
IW/L31/01/06
IW/L31/01/07
IW/L31/01/09
IW/L31/02/01
IW/L31/02/02
IW/L31/03/01
IW/L31/03/02
IW/L31/03/03
IW/L31/03/04
IW/L31/03/05
IW/L31/04/01
IW/L31/05/01
IW/L31/05/05
IW/L31/05/06
IW/L32/02/01
IW/L42/01/01
IW/L42/02/01
IW/L42/03/02
IW/L42/04/01
IW/L42/05/01
IW/L42/06/01
IW/L42/08/01
IW/L42/10/01
IW/L42/11/01
IW/L42/12/01
IW/L42/13/01
IW/L42/13/02
OIML R 124:1997
OIML R14:1995
PN-EN 60645-1:2017
PN-EN 60651:2002
PN-EN 60804:2002
PN-EN 60942:2005
PN-EN 60942:2018
PN-EN 61252:2000
PN-EN 61260-3:2016
PN-EN 61260:2000
PN-EN 61672-3:2007
PN-EN ISO 148-2:2017-02
PN-EN ISO 4787:2022-06
PN-EN ISO 6506-2:2019-10
PN-EN ISO 6507-2:2018-05
PN-EN ISO 6508-2:2024-06
PN-EN ISO 6789-1:2017-03
PN-EN ISO 6789-2:2017-03
PN-EN ISO 7500-1:2018-05
PN-EN ISO 8655-6:2022-11