🇵🇱 PLUM Sp. z o.o. PL

PCA AP 074 • Kleosin, Poland • 32 calibration items

Metrology & calibration

PLUM Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 074 (Kleosin, Poland). Its accreditation scope covers 32 calibration items in the following areas: Metrology & calibration. Calibrated items include: Multimeters, Calibrators, Electrical thermometers, Breakdown testers. Most frequently used calibration principles: Internal procedure; Direct and indirect method; At permanent locati…, Internal procedure; Comparison method; At permanent location (S), Internal procedure; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 074
  • Calibration items in scope: 32
  • Types of calibrated items: 44
  • Calibration principles used: 10
  • City: Kleosin, Poland
  • Valid until: 23-01-2029
Accreditation number
AP 074
Accreditation body
PCA
Address
Ignatki, ul. Wspólna 19, 16-001 Kleosin
City
Kleosin, Poland
Division
Measurement Laboratory
Valid until
23-01-2029

What this laboratory calibrates (44)

Calibration principles (10)

Certificate information

Issue date
12.11.2025
Issue no.
26
Certificate date
14.11.2019
Accreditation cycle
03.01.2025 — 23.01.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (32)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. The value of the uncertainty covered by the CMC expressed as a percentage is the relative measurement uncertainty and refers to the percentage share of the value of the measurand

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Calibrators
Power supplies
Breakdown testers
Reference sources
Breakdown voltage meters
Calibration — DC voltage
0 mV to 100 mV · CMC 5 · 10⁻⁶ · U + 0,0001 mV 0,1 V to 199,99 V · CMC 0,0004 % 1 V · CMC 0,0002 % 10 V · CMC 0,00015 % 199,99 V to 1000 V · CMC 0,0007 % 1000 V to 4000 V · CMC 4,5 · 10⁻³ · U + 10 V
DC voltage
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
2 Multimeters
Digital voltmeters
Oscilloscopes
Electronic loads
Calibration — DC voltage
0 mV · CMC 0,01 µV 0,01 mV to 100 mV · CMC 5 · 10⁻⁶ · U + 0,0001 mV 0,1 V to 19,99 V · CMC 0,0004 % 1 V · CMC 0,0003 % 10 V · CMC 0,0002 % 19,99 V to 199,99 V · CMC 0,0005 % 199,99 V to 1100 V · CMC 0,0006 %
DC voltage
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
3 Calibrators
Power supplies
Electronic loads
Breakdown testers
Breakdown voltage meters
Calibration — DC current
0 µA to 219,99 µA · CMC 1,2 · 10⁻⁵ · I + 0,5 nA 0,21999 mA to 220 mA · CMC 0,0015 % 0,22 A to 2,2 A · CMC 0,0055 % 2,2 A to 20 A · CMC 0,059 %
DC current
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
4 Multimeters
Digital ammeters
Gas volume converters
Clamp meters
Calibration — DC current
0 µA · CMC 0,01 nA 0,01 µA to 10 µA · CMC 1 · 10⁻⁵ · I + 0,43 nA 10 µA to 219,99 µA · CMC 1 · 10⁻⁵ · I + 1,2 nA 0,21999 mA to 219,99 mA · CMC 0,0015 % 0,21999 A to 2,2 A · CMC 0,0057 % 2,2 A to 20 A · CMC 4,5 · 10⁻⁴ · I + 0,0003 A
DC current
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
5 Clamp meters Calibration — DC current
20 A to 1000 A · CMC 5 · 10⁻³ · I + 0,2 A
DC current
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
6 Multimeters
Digital voltmeters
Oscilloscopes
Power quality meters
Calibration — AC voltage
10 Hz to 20 Hz — 1 mV to 2,2 mV · CMC 0,23 % 10 Hz to 20 Hz — 2,2 mV to 22 mV · CMC 0,049 % 10 Hz to 20 Hz — 22 mV to 220 mV · CMC 0,037 % 10 Hz to 20 Hz — 0,22 V to 220 V · CMC 0,029 % 20 Hz to 20 kHz — 1 mV to 2,2 mV · CMC 0,21 % 20 Hz to 20 kHz — 2,2 mV to 22 mV · CMC 0,060 % 20 Hz to 20 kHz — 22 mV to 220 mV · CMC 8 · 10⁻⁵ · U + 0,007 mV 20 Hz to 40 Hz — 0,22 V to 220 V · CMC 0,011 % 40 Hz to 20 kHz — 0,22 V to 219,99 V · CMC 0,007 % 15 Hz to 50 Hz — 219,99 V to 250 V · CMC 0,043 % 50 Hz to 1 kHz — 219,99 V to 1100 V · CMC 7 · 10⁻⁵ · U + 0,004 V 1 kHz to 10 kHz — 219,99 V to 1000 V · CMC 2,5 · 10⁻⁴ · U + 0,035 mV 20 kHz to 50 kHz — 1 mV to 2,2 mV · CMC 0,22 % 20 kHz to 50 kHz — 2,2 mV to 220 mV · CMC 2,5 · 10⁻⁴ · U + 0,004 mV 20 kHz to 50 kHz — 0,22 V to 219,99 V · CMC 1,2 · 10⁻⁴ · U + 0,00005 V 50 kHz to 100 kHz — 1 mV to 2,2 mV · CMC 0,31 % 50 kHz to 100 kHz — 2,2 mV to 220 mV · CMC 7 · 10⁻⁴ · U + 0,004 mV 50 kHz to 100 kHz — 0,22 V to 219,99 V · CMC 2,5 · 10⁻⁴ · U + 0,00005 V 100 kHz to 300 kHz — 1 mV to 2,2 mV · CMC 0,65 % 100 kHz to 300 kHz — 2,2 mV to 220 mV · CMC 0,16 % 100 kHz to 300 kHz — 0,22 V to 2,2 V · CMC 0,051 % 100 kHz to 300 kHz — 2,2 V to 22 V · CMC 0,034 % 300 kHz to 1 MHz — 1 mV to 2,2 mV · CMC 1,6 % 300 kHz to 1 MHz — 2,2 mV to 220 mV · CMC 0,38 % 300 kHz to 1 MHz — 0,22 V to 22 V · CMC 3 · 10⁻³ · U + 0,003 V
AC voltage
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
7 Calibrators
Reference sources
Breakdown testers
Breakdown voltage meters
Generators
Calibration — AC voltage
10 Hz to 40 Hz — 1 mV to 199,99 mV · CMC 2,2 · 10⁻⁴ · U + 0,0057 mV 10 Hz to 40 Hz — 0,2 V to 199,99 V · CMC 0,013 % 10 Hz to 40 Hz — 200 V to 1000 V · CMC 0,021 % 40 Hz to 10 kHz — 1 mV to 199,99 mV · CMC 1,4 · 10⁻⁴ · U + 0,0060 mV 40 Hz to 10 kHz — 0,2 V to 199,99 V · CMC 0,012 % 40 Hz to 10 kHz — 200 V to 1000 V · CMC 1,5 · 10⁻⁴ · U + 0,01 V 10 kHz to 30 kHz — 1 mV to 199,99 mV · CMC 3,5 · 10⁻⁴ · U + 0,0089 mV 10 kHz to 30 kHz — 0,2 V to 199,99 V · CMC 0,025 % 10 kHz to 30 kHz — 200 V to 1000 V · CMC 0,042 % 30 kHz to 100 kHz — 1 mV to 199,99 mV · CMC 8,0 · 10⁻⁴ · U + 0,021 mV 30 kHz to 100 kHz — 0,2 V to 19,99 V · CMC 0,072 % 30 kHz to 100 kHz — 20 V to 199,99 V · CMC 0,085 % 100 kHz to 300 kHz — 0,2 V to 19,99 V · CMC 3,1 % 300 kHz to 500 kHz — 2 V to 19,99 V · CMC 1 · 10⁻² · U + 0,2 V 45 Hz to 65 Hz — 1000 V to 5200 V · CMC 4,5 · 10⁻³ · U + 10 V
AC voltage
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
8 Multimeters
Digital ammeters
Clamp meters
Power quality meters
Calibration — AC current
10 Hz to 20 Hz — 10 µA to 220 µA · CMC 0,042 % 10 Hz to 20 Hz — 0,22 mA to 220 mA · CMC 0,030 % 20 Hz to 1 kHz — 10 µA to 220 µA · CMC 1,3 · 10⁻⁴ · I + 0,009 µA 20 Hz to 1 kHz — 0,22 mA to 220 mA · CMC 0,020 % 20 Hz to 1 kHz — 0,22 A to 2,2 A · CMC 0,031 % 1 kHz to 5 kHz — 10 µA to 220 µA · CMC 2,9 · 10⁻⁴ · I + 0,013 µA 1 kHz to 5 kHz — 0,22 mA to 220 mA · CMC 0,027 % 1 kHz to 5 kHz — 0,22 A to 2,2 A · CMC 0,056 % 5 kHz to 10 kHz — 10 µA to 22 mA · CMC 0,18 % 5 kHz to 10 kHz — 22 mA to 220 mA · CMC 0,12 % 5 kHz to 10 kHz — 0,22 A to 2,2 A · CMC 0,75 % 45 Hz to 2 kHz — 2,2 A to 20 A · CMC 1 · 10⁻³ · I + 0,002 A 2 kHz to 5 kHz — 2,2 A to 20 A · CMC 0,72%
AC current
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
9 Clamp meters Calibration — AC current
50 Hz — 20 A to 1000 A · CMC 2,5 · 10⁻³ · I + 0,1 A
AC current
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
10 Calibrators
Reference sources
Electrical safety testers
Breakdown testers
Breakdown voltage meters
Calibration — AC current
40 Hz to 2 kHz — 10 µA to 1,99 mA · CMC 4,1· 10⁻⁴ · I + 0,015 µA 40 Hz to 2 kHz — 2 mA to 199,99 mA · CMC 4,1· 10⁻⁴ · I + 0,0008 mA 40 Hz to 2 kHz — 0,2 A to 1,99 A · CMC 7,6· 10⁻⁴ · I + 0,00013 A 40 Hz to 2 kHz — 2 A to 19,99 A · CMC 0,11 % 2 kHz to 10 kHz — 10 µA to 19,99 mA · CMC 5,1· 10⁻⁴ · I + 0,012 µA 2 kHz to 10 kHz — 20 mA to 199,99 mA · CMC 3,8· 10⁻⁴ · I + 0,015 mA 2 kHz to 10 kHz — 0,2 A to 1,99 A · CMC 8,9· 10⁻⁴ · I + 0,00011 A 2 kHz to 10 kHz — 2 A to 19,99 A · CMC 0,36 %
AC current
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
11 Calibrators
Reference sources
Electrical safety testers
Calibration — AC current
50 Hz to 60 Hz — 20 A to 25 A · CMC 0,1 A 50 Hz to 60 Hz — 25 A to 30 A · CMC 0,2 A
AC current
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
12 Fixed resistors
Variable resistors
Calibration — DC resistance
0,001 Ω to 0,2 Ω · CMC 0,005 mΩ 0,2 Ω to 5 Ω · CMC 0,001 % 5 Ω to 19,99 Ω · CMC 0,0005 % 20 Ω to 199,99 Ω · CMC 0,0003 % 0,2 kΩ to 1,999 kΩ · CMC 0,0005 % 2 kΩ to 19,99 kΩ · CMC 0,0003 % 20 kΩ to 199,99 kΩ · CMC 0,0005 % 0,2 MΩ to 1,999 MΩ · CMC 0,0012 % 2 MΩ to 19,99 MΩ · CMC 0,003 % 20 MΩ to 199,99 MΩ · CMC 0,01 % 0,2 GΩ to 1,999 GΩ · CMC 0,04 %
DC resistance
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/7 based on EURAMET cg-15 v.3.0
13 Resistance calibrators Calibration — DC resistance
0,001 Ω to 0,2 Ω · CMC 0,005 mΩ 0,2 Ω to 5 Ω · CMC 0,001 % 5 Ω to 19,99 Ω · CMC 0,0005 % 20 Ω to 199,99 Ω · CMC 0,0003 % 0,2 kΩ to 1,999 kΩ · CMC 0,0005 % 2 kΩ to 19,99 kΩ · CMC 0,0003 % 20 kΩ to 199,99 kΩ · CMC 0,0005 % 0,2 MΩ to 1,999 MΩ · CMC 0,0012 % 2 MΩ to 19,99 MΩ · CMC 0,003 % 20 MΩ to 199,99 MΩ · CMC 0,01 % 0,2 GΩ to 1,999 GΩ · CMC 0,04 %
DC resistance
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
14 Multimeters
Digital ohmmeters
Calibration — DC resistance
0 Ω · CMC 0,00005 mΩ 0,001 Ω to 0,2 Ω · CMC 0,008 mΩ 0,001 Ω · CMC 0,12 % 0,01 Ω · CMC 0,012 % 0,1 Ω · CMC 0,0025 % 0,2 Ω to 2 Ω · CMC 0,004 % 1 Ω · CMC 0,00025 % 1,9 Ω · CMC 0,0031 % 2 Ω to 10 Ω · CMC 0,002 % 10 Ω · CMC 0,0008 % 10 Ω to 199,99 Ω · CMC 0,0015 % 19 Ω · CMC 0,00065 % 25 Ω · CMC 0,00028 % 100 Ω · CMC 0,00025 % 190 Ω · CMC 0,00038 % 0,2 kΩ to 199,99 kΩ · CMC 0,0015 % 1 kΩ · CMC 0,00055 % 1,9 kΩ · CMC 0,00058 % 10 kΩ · CMC 0,00025 % 19 kΩ · CMC 0,00038 % 100 kΩ · CMC 0,00055 % 190 kΩ · CMC 0,001 % 0,2 MΩ to 1,999 MΩ · CMC 0,002 % 1 MΩ · CMC 0,0013% 1,9 MΩ · CMC 0,0013 % 2 MΩ to 19,99 MΩ · CMC 0,0035 % 10 MΩ · CMC 0,0028 % 19 MΩ · CMC 0,0034 % 20 MΩ to 199,99 MΩ · CMC 0,015 % 100 MΩ · CMC 0,012 % 0,2 GΩ to 1 GΩ · CMC 0,07 % 1 GΩ · CMC 0,015 % 1 GΩ to 20 GΩ · CMC 1,5· 10⁻³ · R + 0,01 GΩ
DC resistance
Internal procedure; Direct and indirect method; At permanent location (S) ILAJ 5.4/6 based on EURAMET cg-15 v.3.0
15 Digital ohmmeters
Electrical safety testers
Calibration — AC resistance
current up to 30 A, 50 Hz to 60 Hz — 10 mΩ to 102 mΩ · CMC 1 mΩ current up to 30 A, 50 Hz to 60 Hz — 102 mΩ to 210 mΩ · CMC 2 mΩ
AC resistance
Internal procedure; Indirect method; At permanent location (S) ILAJ 5.4/6
16 Multimeters
Capacitance meters
Calibration — Capacitance
0,4 nF to 11 nF · CMC 2 · 10⁻³ · C + 0,02 nF 11 nF to 330 nF · CMC 3 · 10⁻³ · C + 0,1 nF 0,33 µF to 11 µF · CMC 3 · 10⁻³ · C + 1 nF 11 µF to 100 µF · CMC 5 · 10⁻³ · C + 10 nF
Capacitance
Internal procedure; Direct method; At permanent location (S) ILAJ 5.4/6
17 Temperature simulators Calibration — Electrical simulation of quantities
-200 °C to 200 °C · CMC 0,005 °C 200 °C to 500 °C · CMC 0,010 °C 500 °C to 850 °C · CMC 0,015 °C
Electrical simulation of quantities
Internal procedure; Indirect electrical method; At permanent location (S) ILAJ 5.4/7 based on EURAMET cg-11 v.2.0 PN-EN 60751:2022
18 Temperature indicators (meters)
(for use with resistance thermometer sensors)
Calibration — Electrical simulation of quantities
-200 °C to 200 °C · CMC 0,005 °C 200 °C to 500 °C · CMC 0,010 °C 500 °C to 850 °C · CMC 0,015 °C
Electrical simulation of quantities
Internal procedure; Indirect electrical method; At permanent location (S) ILAJ 5.4/8 based on EURAMET cg-11 v.2.0 PN-EN 60751:2022
19 Temperature indicators (meters)
including temperature controllers
Calibration — Electrical simulation of quantities
-200 °C to 1820 °C · CMC (0,04 · Z + 0,5) · 10⁻³ °C
Electrical simulation of quantities
Internal procedure; Indirect electrical method Using the characteristics of temperature transmitters with an analogue voltage or current electrical signal; At permanent location (S) ILAJ 5.4/8 based on EURAMET cg-11 v.2.0 PN-EN 60751:2022
20 Multimeters
Calibrators
Digital frequency meters
Oscilloscopes
Frequency generators
Calibration — Frequency
1 Hz to 1000 Hz · CMC 3 · 10⁻⁶ · f + 0,00001 Hz 1 kHz do 100 MHz · CMC 0,0003 %
Frequency
Internal procedure; Direct method; At permanent location (S) ILAJ 5.4/6
21 Hygrometers
Thermohygrometers
Transmitters
Calibration — Relative humidity
at t = 22 °C to 60 °C and 10 %rh — 10 %rh to 95 %rh · CMC 0,9 %rh at t = 22 °C to 60 °C and 95 %rh — 10 %rh to 95 %rh · CMC 1,2 %rh at t = 10 °C and 22 %rh — 22 %rh to 95 %rh · CMC 1,2 %rh at t = 10 °C and 95 %rh — 22 %rh to 95 %rh · CMC 1,2 %rh
Relative humidity
Internal procedure; Calibration in a climatic chamber; At permanent location (S) ILAJ 5.4/11
22 Electronic pressure gauges (calibrators)
Gas volume converters with pressure measurement function
Pressure transmitters
Bourdon tube pressure gauges
- gauge pressure (gas, liquid)
Calibration — Pressure
-100 kPa to -5 kPa · CMC -4,4·10⁻⁵ · p + 0,0007 kPa -5 kPa to 10 kPa · CMC 0,001 kPa 10 kPa to 170 kPa · CMC 4,1 · 10⁻⁵ · p + 0,0006 kPa 170 kPa to 700 kPa · CMC 3,0 · 10⁻⁵ · p + 0,006 kPa 700 kPa to 1000 kPa · CMC 1,7 · 10⁻⁴ · p - 0,09 kPa 1000 kPa to 7000 kPa · CMC 2,9 · 10⁻⁵ · p + 0,05 kPa 7000 kPa to 10000 kPa · CMC 0,0002 · p 10000 kPa to 14000 kPa · CMC 3,5 kPa 14000 kPa to 35000 kPa · CMC 9,0 kPa 35000 kPa to 70000 kPa · CMC 18 kPa
Pressure
Internal procedure; At permanent location (S) ILAJ 5.4/4 ILAJ 5.4/5 ILAJ 5.4/14
23 Electronic pressure gauges (calibrators)
Gas volume converters with pressure measurement function
Pressure transmitters
Bourdon tube pressure gauges
Barometers
- absolute pressure (gas, liquid)
Calibration — Pressure
1,4 kPa to 80 kPa · CMC 0,004 kPa 80 kPa to 170 kPa · CMC 2,9 · 10⁻⁵ · p + 0,0017 kPa 170 kPa to 700 kPa · CMC 3,5 · 10⁻⁵ · p + 0,0025 kPa 700 kPa to 1000 kPa · CMC 1,4 · 10⁻⁴ · p - 0,07 kPa 1000 kPa to 7000 kPa · CMC 3 · 10⁻⁵ · p + 0,04 kPa 7000 kPa to 10000 kPa · CMC 0,0002 · p 10000 kPa to 14000 kPa · CMC 3,5 kPa 14000 kPa to 35000 kPa · CMC 9,0 kPa 35000 kPa to 70000 kPa · CMC 18 kPa
Pressure
Internal procedure; At permanent location (S) ILAJ 5.4/4 ILAJ 5.4/5 ILAJ 5.4/14
24 Resistance thermometer sensors Calibration — Temperature (electrical thermometry)
-40 °C to 230 °C · CMC 0,008 °C
Temperature (electrical thermometry)
Internal procedure; Comparison method; At permanent location (S) ILAJ 5.4/1
25 Resistance thermometer sensors Calibration — Temperature (electrical thermometry)
-40 °C to 230 °C · CMC 0,010 °C
Temperature (electrical thermometry)
Internal procedure; Comparison method; At permanent location (S) ILAJ 5.4/1
26 Resistance thermometer sensors Calibration — Temperature (electrical thermometry)
-38,8344 °C · CMC 0,0030 °C 0,01 °C · CMC 0,0025 °C 29,7646 °C · CMC 0,0030 °C 156,5985 °C · CMC 0,0040 °C 231,9280 °C · CMC 0,0050 °C
Temperature (electrical thermometry)
Internal procedure; Calibration at fixed points; At permanent location (S) ILAJ 5.4/1
27 Temperature transmitters
(containing temperature sensors)
Calibration — Temperature (electrical thermometry)
-40 °C to 230 °C · CMC 0,010 °C
Temperature (electrical thermometry)
Internal procedure; Comparison method; At permanent location (S) ILAJ 5.4/2
28 Electrical thermometers
(including electronic)
Electrical thermometers
(with temperature recording)
Calibration — Temperature (electrical thermometry)
-40 °C to 230 °C · CMC 0,010 °C
Temperature (electrical thermometry)
Internal procedure; Comparison method; At permanent location (S) ILAJ 5.4/3
29 Electrical thermometers
(including electronic)
Electrical thermometers
(with temperature recording)
Calibration — Temperature (electrical thermometry)
-38,8344 °C · CMC 0,0040 °C 0,01 °C · CMC 0,0035 °C 29,7646 °C · CMC 0,0040 °C 156,5985 °C · CMC 0,0050 °C 231,9280 °C · CMC 0,0060 °C
Temperature (electrical thermometry)
Internal procedure; Calibration at fixed points; At permanent location (S) ILAJ 5.4/3
30 Electrical thermometers
(including electronic)
Electrical thermometers
(with temperature recording)
Temperature transmitters
(containing temperature sensors)
Calibration — Temperature (electrical thermometry)
-30 °C to 80 °C · CMC 0,1 °C
Temperature (electrical thermometry)
Internal procedure; Calibration in a climatic chamber Comparison method; At permanent location (S) ILAJ 5.4/11
31 Temperature calibrators Calibration — Temperature (electrical thermometry)
-40 °C to 160 °C · CMC 0,14 °C
Temperature (electrical thermometry)
Internal procedure; At permanent location (S) ILAJ 5.4/16 based on EURAMET cg-13 v.4.0
32 Photoelectric and radiation pyrometers Calibration — Temperature (radiation thermometry)
-15 °C do 100 °C · CMC 0,8 °C 100 °C to 200 °C · CMC 1,2 °C 200 °C do 300 °C · CMC 1,5 °C 300 °C do 400 °C · CMC 2,0 °C 400 °C do 500 °C · CMC 2,4 °C
Temperature (radiation thermometry)
Internal procedure; Comparison method; At permanent location (S) ILAJ 5.4/15

Reference standards (16)

EURAMET cg-11 v.2.0
EURAMET cg-13 v.4.0
EURAMET cg-15 v.3.0
ILAJ 5.4/1
ILAJ 5.4/11
ILAJ 5.4/14
ILAJ 5.4/15
ILAJ 5.4/16
ILAJ 5.4/2
ILAJ 5.4/3
ILAJ 5.4/4
ILAJ 5.4/5
ILAJ 5.4/6
ILAJ 5.4/7
ILAJ 5.4/8
PN-EN 60751:2022

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20074