🇵🇱 Narodowe Centrum Badań Jądrowych PL
Metrology & calibration
Narodowe Centrum Badań Jądrowych is a calibration laboratory accredited by PCA under number AP 070 (Otwock, Poland). Its accreditation scope covers 7 calibration items in the following areas: Metrology & calibration. Calibrated items include: Ionising radiation dosimeters, Passive dosimeters, Dosimetric instruments for gamma radiation measurement, Dosimetric instruments for neutron radiation measurement. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Measurement; At permanent location (S), Internal procedure.
At a glance
- Accreditation number: PCA AP 070
- Calibration items in scope: 7
- Types of calibrated items: 5
- Calibration principles used: 3
- City: Otwock, Poland
- Valid until: 04-11-2028
- Accreditation number
- AP 070
- Accreditation body
- PCA
- Address
- ul. Andrzeja Sołtana 7, 05-400 Otwock
- City
- Otwock, Poland
- Division
- Laboratorium Pomiarów Dozymetrycznych, Dział Kalibracji Aparatury Dozymetrycznej
- Valid until
- 04-11-2028
What this laboratory calibrates (5)
- Ionising radiation dosimeters — 3 calibration items
- Passive dosimeters — 2 calibration items
- Dosimetric instruments for gamma radiation measurement — 1 calibration item
- Dosimetric instruments for neutron radiation measurement — 1 calibration item
- Meters and monitors for alpha and/or beta radioactive contamination measurement — 1 calibration item
Calibration principles (3)
- Internal procedure; At permanent location (S) — 4 calibration items
- Internal procedure; Measurement; At permanent location (S) — 2 calibration items
- Internal procedure — 1 calibration item
Certificate information
- Issue date
- 17.10.2024
- Issue no.
- 19
- Certificate date
- 03.07.2019
- Accreditation cycle
- 17.10.2024 — 04.11.2028
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (7)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Dosimetric instruments for gamma radiation measurement Ionising radiation dosimeters |
Calibration — Dosimetric quantities air kerma rate — 1 μGy·h⁻¹ to 50 mGy·h⁻¹ · CMC 3,5 % ambient dose equivalent rate — 1 μSv·h⁻¹ to 50 mSv·h⁻¹ · CMC 5 % exposure rate — 0,1 mR·h⁻¹ to 5 R·h⁻¹ · CMC 3,5 % air kerma — 1 μGy to 10 Gy · CMC 4 % ambient dose equivalent — 1 μSv to 10 Sv · CMC 5 % personal dose equivalent — 1 μSv to 10 Sv · CMC 5 % exposure — 0,1 mR to 1 kR · CMC 4 % Dosimetric quantities |
Internal procedure; At permanent location (S) | G-1 | |
| 2 | Passive dosimeters | Calibration — Dosimetric quantities air kerma — 10 μGy to 10 Gy · CMC 2,5 % ambient dose equivalent — 10 μSv to 10 Sv · CMC 5,5 % personal dose equivalent — 10 μSv to 10 Sv · CMC 5,5 % Dosimetric quantities |
Internal procedure; Measurement; At permanent location (S) | G-2 | |
| 3 | Ionising radiation dosimeters | Calibration — Dosimetric quantities air kerma — 10 μGy to 10 Gy · CMC 2,5 % ambient dose equivalent — 10 μSv to 10 Sv · CMC 5,5 % personal dose equivalent — 10 μSv to 10 Sv · CMC 5,5 % Dosimetric quantities |
Internal procedure; At permanent location (S) | G-2 | |
| 4 | Dosimetric instruments for neutron radiation measurement | Calibration — Dosimetric quantities fast neutron fluence rate — 3 cm⁻²·s⁻¹ to 900 cm⁻²·s⁻¹ · CMC 3 % neutron ambient dose equivalent rate — 10 μSv·h⁻¹ to 1500 μSv·h⁻¹ · CMC 10 % neutron dose equivalent rate — 1 mrem·h⁻¹ to 150 mrem·h⁻¹ · CMC 10 % Dosimetric quantities |
Internal procedure; At permanent location (S) | N-1 | |
| 5 | Passive dosimeters | Calibration — Dosimetric quantities ambient dose equivalent — 25 μSv to 10 mSv · CMC 10,5 % personal dose equivalent — 25 μSv to 10 mSv · CMC 10,5 % Dosimetric quantities |
Internal procedure; Measurement; At permanent location (S) | N-2 | |
| 6 | Ionising radiation dosimeters | Calibration — Dosimetric quantities ambient dose equivalent — 25 μSv to 10 mSv · CMC 10,5 % personal dose equivalent — 25 μSv to 10 mSv · CMC 10,5 % Dosimetric quantities |
Internal procedure | N-2 | |
| 7 | Meters and monitors for alpha and/or beta radioactive contamination measurement | Calibration — Surface emission of radiation surface emission of radiation, alpha radiation: ²⁴¹Am — 11,6 s⁻¹·cm⁻² · CMC 4,5 % beta radiation: ³⁶Cl — 11,9 s⁻¹·cm⁻² · CMC 4,5 % beta radiation: ⁹⁰Sr — 21,3 s⁻¹·cm⁻² · CMC 4,5 % beta radiation: ¹⁴C — 25,1 s⁻¹·cm⁻² · CMC 4,5 % Surface emission of radiation |
Internal procedure; At permanent location (S) | P-1 | |
Reference standards (5)
G-1
G-2
N-1
N-2
P-1