🇵🇱 LAB-EL Elektronika Laboratoryjna Sp. z o.o. PL

PCA AP 067 • Reguły, Poland • 15 calibration items

Metrology & calibration

LAB-EL Elektronika Laboratoryjna Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 067 (Reguły, Poland). Its accreditation scope covers 15 calibration items in the following areas: Metrology & calibration. Calibrated items include: Electrical thermometers (including electronic), Electrical thermometers (with temperature recording), Temperature transmitters (containing temperature sensors), Climatic chambers. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; At permanent location (S) and outside of it (P), Internal procedure; Calibration in a climatic chamber; At permanent….

At a glance

  • Accreditation number: PCA AP 067
  • Calibration items in scope: 15
  • Types of calibrated items: 21
  • Calibration principles used: 7
  • City: Reguły, Poland
  • Valid until: 03-06-2028
Accreditation number
AP 067
Accreditation body
PCA
Address
ul. Herbaciana 9, 05-816 Reguły
City
Reguły, Poland
Division
LAB-EL Humidity, Temperature and Pressure Laboratory
Valid until
03-06-2028

What this laboratory calibrates (21)

Calibration principles (7)

Certificate information

Issue date
01.09.2025
Issue no.
22
Certificate date
29.05.2020
Accreditation cycle
15.05.2024 — 03.06.2028
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (15)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Anemometers Calibration — Air velocity (flow - gases)
1,0 m/s to 1,5m/s · CMC 0,1 m/s 1,5 m/s to 15,0 m/s · CMC 0,2 m/s 15,0 m/s to 40,0 m/s · CMC 0,2 + 0,025 · (V – 15) m/s; V – measured value (m/s)
Air velocity (flow - gases)
Internal procedure; At permanent location (S) SOP-29 SOP-10.IR.15
2 Thermal anemometers Calibration — Air velocity (flow - gases)
0,3 m/s to 5,0 m/s · CMC 0,1 m/s 5,0 m/s to 15,0 m/s · CMC 0,0469 + 0,0102 · V m/s; V – measured value (m/s) 15,0 m/s to 40,0 m/s · CMC 0,2 + 0,025 · (V – 15) m/s; V – measured value (m/s)
Air velocity (flow - gases)
Internal procedure; At permanent location (S) SOP-29 SOP-10.IR.15
3 Hygrometers Calibration — Dew-point temperature
-10 °C to 40 °C · CMC 0,2 °C
Dew-point temperature
Internal procedure; Calibration in a climatic chamber; At permanent location (S) SOP-22 SOP-10.IR.09
4 Hygrometers
Thermohygrometers
Psychrometers
Transmitters
Calibration — Relative humidity
at temperature -5 °C — 68 %rh · CMC 1,1 %rh at temperature -5 °C — 98 %rh · CMC 1,2 %rh at temperature 0 °C — 47 %rh · CMC 0,6 %rh at temperature 0 °C — 98 %rh · CMC 1,1 %rh at temperature 21 °C — 12 %rh · CMC 0,5 %rh at temperature 21 °C — 98 %rh · CMC 0,8 %rh at temperature 40 °C — 10 %rh · CMC 0,4 %rh at temperature 40 °C — 98 %rh · CMC 0,8 %rh at temperature 60 °C — 10 %rh · CMC 0,5 %rh at temperature 60 °C — 38 %rh · CMC 0,8 %rh
Relative humidity
Internal procedure; Calibration in a climatic chamber in the temperature range -5 °C to 60 °C; At permanent location (S) SOP-14 SOP-10.IR.01
5 Climatic chambers Calibration — Relative humidity
temperature range 5 °C to 60 °C — 10 %rh to 98 %rh · CMC 2,7 %rh
Relative humidity
Internal procedure; At permanent location (S) and outside of it (P) SOP-25 SOP-10.IR.11
6 Barometers
Electronic pressure gauges
Spring pressure gauges
Pressure transmitters
- absolute pressure (gas medium)
Calibration — Pressure
700 hPa to 1100 hPa · CMC 0,2 hPa
Pressure
Internal procedure; At permanent location (S) SOP-18 SOP-10.IR.06
7 Electronic pressure gauges
Spring pressure gauges
Pressure transmitters
- gauge pressure (gas medium)
Calibration — Pressure
-1470 Pa to 1470 Pa · CMC 2,0 Pa -200 Pa to 200 Pa · CMC 0,5 Pa
Pressure
Internal procedure; At permanent location (S) SOP-18 SOP-10.IR.06
8 Electrical thermometers (including electronic)
Electrical thermometers (with temperature recording)
Temperature transmitters (containing temperature sensors)
Calibration — Temperature (electrical thermometry)
-10 °C to 60 °C · CMC 0,12 °C
Temperature (electrical thermometry)
Internal procedure; Calibration in a climatic chamber; At permanent location (S) SOP-14 SOP-10.IR.02 SOP-10.IR.03
9 Resistance thermometer sensors
Electrical thermometers (including electronic)
Electrical thermometers (with temperature recording)
Temperature transmitters (containing temperature sensors)
Calibration — Temperature (electrical thermometry)
-80 °C to 250 °C · CMC 0,02 °C
Temperature (electrical thermometry)
Internal procedure; Calibration in a liquid thermostat; At permanent location (S) SOP-13 SOP-15 SOP-10.IR.02 SOP-10.IR.03 SOP-10.IR.04 SOP-10.IR.05
10 Resistance thermometer sensors
Electrical thermometers (including electronic)
Electrical thermometers (with temperature recording)
Temperature transmitters (containing temperature sensors)
Calibration — Temperature (non-electrical thermometry)
-90 °C to 250 °C · CMC 0,14 °C 250 °C to 420 °C · CMC 0,22 °C 420 °C to 650 °C · CMC 0,37 °C
Temperature (non-electrical thermometry)
Internal procedure; Calibration in a temperature calibrator; At permanent location (S) and outside of it (P) SOP-13 SOP-15 SOP-21 SOP-10.IR.02 SOP-10.IR.03 SOP-10.IR.04 SOP-10.IR.05
11 Electrical thermometers (including electronic)
Electrical thermometers (with temperature recording)
Temperature transmitters (containing temperature sensors)
Calibration — Temperature (non-electrical thermometry)
-195,8 °C · CMC 0,5 °C
Temperature (non-electrical thermometry)
Internal procedure; Calibration at the fixed temperature of liquid nitrogen; At permanent location (S) SOP-13 SOP-15 SOP-21 SOP-27 SOP-10.IR.13
12 Climatic chambers
Thermostatic chambers1)
Calibration — Temperature (non-electrical thermometry)
-90 °C to 250 °C · CMC 0,2 °C
Temperature (non-electrical thermometry)
Internal procedure; At permanent location (S) and outside of it (P) SOP-21 SOP-25 SOP-10.IR.11
13 Liquid thermostats Calibration — Temperature (non-electrical thermometry)
-30 °C to 80 °C · CMC 0,2 °C
Temperature (non-electrical thermometry)
Internal procedure; At permanent location (S) and outside of it (P) SOP-21 SOP-25 SOP-10.IR.11
14 Liquid-in-glass thermometers Calibration — Temperature (non-electrical thermometry)
-50 °C to 150 °C · CMC 0,1 °C
Temperature (non-electrical thermometry)
Internal procedure; At permanent location (S) SOP-30 SOP-10.IR.16
15 Pyrometers (including radiation photoelectric and multiband pyrometers, thermal imaging cameras) Calibration — Temperature (radiation thermometry)
-15 °C do 0 °C · CMC 1,6 °C 0 °C do 50 °C · CMC 1,1 °C 50 °C do 100 °C · CMC 1,4 °C 100 °C to 200 °C · CMC 1,8 °C 200 °C do 350 °C · CMC 2,3 °C 350 °C do 500 °C · CMC 3,0 °C
Temperature (radiation thermometry)
Internal procedure; At permanent location (S) SOP-23 SOP-10.IR.10

Reference standards (23)

SOP-10.IR.01
SOP-10.IR.02
SOP-10.IR.03
SOP-10.IR.04
SOP-10.IR.05
SOP-10.IR.06
SOP-10.IR.09
SOP-10.IR.10
SOP-10.IR.11
SOP-10.IR.13
SOP-10.IR.15
SOP-10.IR.16
SOP-13
SOP-14
SOP-15
SOP-18
SOP-21
SOP-22
SOP-23
SOP-25
SOP-27
SOP-29
SOP-30

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20067