🇵🇱 Zakład Pomiarowo-Badawczy Energetyki "ENERGOPOMIAR-ELEKTRYKA" Sp. z o.o. PL

PCA AP 063 • Gliwice, Poland • 24 calibration items

Metrology & calibration

Zakład Pomiarowo-Badawczy Energetyki "ENERGOPOMIAR-ELEKTRYKA" Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 063 (Gliwice, Poland). Its accreditation scope covers 24 calibration items in the following areas: Metrology & calibration. Calibrated items include: Multimeters, Power quality (network parameter) meters, Analogue and digital current meters, Analogue and digital resistance meters. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S) and ou…, Internal procedure; Direct method; At permanent location (S), Internal procedure; Direct method; Outside of permanent location (P).

At a glance

  • Accreditation number: PCA AP 063
  • Calibration items in scope: 24
  • Types of calibrated items: 17
  • Calibration principles used: 3
  • City: Gliwice, Poland
  • Valid until: 19-02-2028
Accreditation number
AP 063
Accreditation body
PCA
Address
ul. Świętokrzyska 2, 44-100 Gliwice
City
Gliwice, Poland
Division
Measuring Instruments Laboratory
Valid until
19-02-2028

What this laboratory calibrates (17)

Calibration principles (3)

Certificate information

Issue date
06.12.2024
Issue no.
19
Certificate date
28.09.2023
Accreditation cycle
08.02.2024 — 19.02.2028
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (24)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. A value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand. In other cases the CMC uncertainty is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Analogue and digital voltage meters
Multimeters
Calibration — DC voltage
1 mV to 200 mV · CMC 0,1 % 200 mV to 1000 V · CMC 0,03 %
DC voltage
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-01, PP-02, PP-06 based on EURAMET cg-15 v. 3.0
2 Power supplies
Voltage sources
Calibration — DC voltage
0 V to 1000 V · CMC 0,3 %
DC voltage
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-04
3 Clamp meters Calibration — DC current
10 mA to 1000 A · CMC 0,5 %
DC current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-01, PP-02
4 Analogue and digital current meters
Multimeters
Calibration — DC current
0,01 mA to 20 A · CMC 0,1 %
DC current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-01, PP-02 based on EURAMET cg-15 v. 3.0
5 Power supplies Calibration — DC current
0 A to 400 A · CMC 0,5 %
DC current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-04, PP-06
6 DC current sources Calibration — DC current
0 mA to 24 mA · CMC 0,05 %
DC current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-04
7 Analogue and digital voltage meters
Multimeters
Calibration — AC voltage
f = 50 Hz — 10 mV to 200 mV · CMC 0,2 % f = 50 Hz — 200 mV to 1000 V · CMC 0,1 %
AC voltage
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-01, PP-02
8 Power quality (network parameter) meters Calibration — AC voltage
f = 50 Hz; THD U factor (up to the 50th) — 0 % to 40 % · CMC 1,2 %
AC voltage
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-02
9 Power quality (network parameter) meters Calibration — AC voltage
f = 50 Hz; voltage harmonics (up to the 50th) — 0 V to 300 V · CMC 1,2 %
AC voltage
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-02
10 Transformer turns ratio meters Calibration — AC voltage
1 V/V to 1000 V/V · CMC 0,2 %
AC voltage
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-01, PP-02
11 Clamp meters Calibration — AC current
f = 50 Hz — 10 mA to 1000 A · CMC 0,5 %
AC current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-01, PP-02
12 Analogue and digital current meters
Multimeters
Calibration — AC current
f = 50 Hz — 0,01 mA to 20 A · CMC 0,1 % f = 50 Hz — 20 A to 150 A · CMC 0,2 %
AC current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-01, PP-02 based on EURAMET cg-15 v. 3.0
13 Power quality (network parameter) meters Calibration — AC current
f = 50 Hz; THD I factor (up to the 50th) — 0 % to 40 % · CMC 1,2 % f = 50 Hz; THD I factor (up to the 50th) using a clamp-on transducer — 0 % to 40 % · CMC 1,3 %
AC current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-02
14 Power quality (network parameter) meters Calibration — AC current
f = 50 Hz; current harmonics (up to the 50th) — 0 A to 25 A · CMC 1,2 % f = 50 Hz; current harmonics (up to the 50th) using a clamp-on transducer — 0 A to 1000 A · CMC 1,3 %
AC current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-02
15 Fixed resistors
Shunts
Calibration — DC resistance
0,0001 Ω · CMC 0,05 % 0,001 Ω; 0,01 Ω; 0,1 Ω; 0,3 Ω; 1 Ω; 10 Ω; 100 Ω; 1000 Ω 10000 Ω · CMC 0,005 %
DC resistance
Internal procedure; Direct method; At permanent location (S) PP-03, PP-06
16 Fixed and variable resistors
Shunts
Calibration — DC resistance
0,0001 Ω to 1 Ω · CMC 0,1 % 1 Ω to 1 MΩ · CMC 0,06 %
DC resistance
Internal procedure; Direct method; At permanent location (S) PP-03
17 Analogue and digital resistance meters
Multimeters
Bridges
Calibration — DC resistance
0,0001 Ω to 2 Ω · CMC 0,1 % 2 Ω to 20 MΩ · CMC 0,2 % 20 MΩ to 100 GΩ · CMC 0,5 %
DC resistance
Internal procedure; Direct method; At permanent location (S) PP-01, PP-02, PP-05
18 Analogue and digital resistance meters
Multimeters
Calibration — DC resistance
0,1 Ω to 100 GΩ · CMC 0,5 %
DC resistance
Internal procedure; Direct method; Outside of permanent location (P) PP-01, PP-02
19 Multimeters Calibration — Capacitance
0,001 μF to 0,01 μF · CMC 0,02 nF 0,01 μF to 100 μF · CMC 0,6 %
Capacitance
Internal procedure; Direct method; At permanent location (S) PP-02
20 Power quality (network parameter) meters Calibration — Phase angle
f = 50 Hz — cosφ ±(1 to 0,2) · CMC 1,1 %
Phase angle
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-02
21 Analogue and digital power meters (single-phase and three-phase) Calibration — AC power
30 V do 500 V; 0,1 A do 50 A; cosφ ±1 · CMC 0,1 % 30 V do 500 V; 0,1 A do 50 A; sinφ ±1 · CMC 0,1 % 30 V do 500 V; 50 A do 1000 A; cosφ ±1 · CMC 0,6 % 30 V do 500 V; 50 A do 1000 A; sinφ ±1 · CMC 0,6 % 30 V do 500 V; 0,1 A do 50 A; cosφ ±(1 do 0,5) · CMC 0,4 % 30 V do 500 V; 0,1 A do 50 A; sinφ ±(1 do 0,5) · CMC 0,4 % 30 V do 500 V; 50 A do 1000 A; cosφ ±(1 do 0,5) · CMC 0,7 % 30 V do 500 V; 50 A do 1000 A; sinφ ±(1 do 0,5) · CMC 0,7 %
AC power
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-01, PP-02
22 Breakdown (dielectric strength) testers Calibration — High voltage and current
DC, f = 50 Hz — 0,5 kV to 100 kV · CMC 2,0 %
High voltage and current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-08
23 Temperature indicators (meters) Calibration — Electric quantity simulation
-50 °C to 1350 °C · CMC 1,5 °C
Electric quantity simulation
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-02
24 Multimeters Calibration — Frequency
10 Hz to 10 MHz · CMC 0,001 %
Frequency
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PP-02, PP-06

Reference standards (8)

EURAMET cg-15 v. 3.0
PP-01
PP-02
PP-03
PP-04
PP-05
PP-06
PP-08

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20063