🇵🇱 Sieć Badawcza Łukasiewicz - Instytut Sztucznej Inteligencji i Cyberbezpieczeństwa PL

PCA AP 051 • Katowice, Poland • 14 calibration items

Metrology & calibration

Sieć Badawcza Łukasiewicz - Instytut Sztucznej Inteligencji i Cyberbezpieczeństwa is a calibration laboratory accredited by PCA under number AP 051 (Katowice, Poland). Its accreditation scope covers 14 calibration items in the following areas: Metrology & calibration. Calibrated items include: Measurement cards, Multimeters, Analogue current meters, Analogue voltage meters. Most frequently used calibration principles: Internal procedure; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 051
  • Calibration items in scope: 14
  • Types of calibrated items: 17
  • Calibration principles used: 1
  • City: Katowice, Poland
  • Valid until: 13-02-2027
Accreditation number
AP 051
Accreditation body
PCA
Address
ul. Leopolda 31, 40-189 Katowice
City
Katowice, Poland
Division
Testing and Certification Centre, Calibration Laboratory
Valid until
13-02-2027

What this laboratory calibrates (17)

Calibration principles (1)

Certificate information

Issue date
05.08.2025
Issue no.
23
Certificate date
05.08.2025
Accreditation cycle
23.01.2023 — 13.02.2027
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (14)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. A value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand. In other cases the CMC uncertainty is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Analogue voltage meters
Digital voltage meters
Multimeters
Measurement cards
Calibration — DC voltage
2 mV to 20 mV · CMC 0,07 % 20 mV to 200 mV · CMC 0,009 % 0,2 V to 1000 V · CMC 0,005 %
DC voltage
Internal procedure; At permanent location (S) L-PW-E01 L-PW-E02 based on EURAMET cg-15 v 3.0
2 Analogue current meters
Digital current meters
Multimeters
Measurement cards
Calibration — DC current
0,02 mA to 0,2 mA · CMC 0,12 % 0,2 mA to 200 mA · CMC 0,02 % 0,2 A to 2 A · CMC 0,03 % 2 A to 20 A · CMC 0,12 %
DC current
Internal procedure; At permanent location (S) L-PW-E01 L-PW-E02 based on EURAMET cg-15 v 3.0
3 Analogue voltage meters
Digital voltage meters
Multimeters
Measurement cards
Calibration — AC voltage
50 Hz to 1 kHz — 2 mV to 20 mV · CMC 0,32 % 50 Hz to 1 kHz — 0,02 V to 200 V · CMC 0,045 % 50 Hz to 1 kHz — 200 V to 1000 V · CMC 0,06 % 1 kHz to 5 kHz — 2 mV to 20 mV · CMC 0,54 % 1 kHz to 5 kHz — 0,02 V to 200 V · CMC 0,06 % 1 kHz to 5 kHz — 200 V to 1000 V · CMC 0,08 % 5 kHz to 100 kHz — 2 mV to 20 mV · CMC 1,5 % 5 kHz to 100 kHz — 0,02 V to 200 V · CMC 0,05 %
AC voltage
Internal procedure; At permanent location (S) L-PW-E01 L-PW-E02 based on EURAMET cg-15 v 3.0
4 Analogue current meters
Digital current meters
Multimeters
Measurement cards
Calibration — AC current
50 Hz to 1 kHz — 0,02 mA to 0,2 mA · CMC 3,0 % 50 Hz to 1 kHz — 0,2 mA to 2 mA · CMC 0,2 % 50 Hz to 1 kHz — 2 mA to 20 mA · CMC 0,08 % 50 Hz to 1 kHz — 0,02 A to 20 A · CMC 0,14 % 1 kHz to 5 kHz — 0,2 mA to 2 mA · CMC 1,3 % 1 kHz to 5 kHz — 2 mA to 20 mA · CMC 0,27 % 1 kHz to 5 kHz — 0,02 A to 2 A · CMC 0,14 %
AC current
Internal procedure; At permanent location (S) L-PW-E01 L-PW-E02 based on EURAMET cg-15 v 3.0
5 Multimeters
Digital resistance meters
Measurement cards
Calibration — DC resistance
0,01 Ω to 0,1 Ω · CMC 0,0058 Ω 0,1 Ω to 5 Ω · CMC 0,1 % 5 Ω MΩ to 1 MΩ · CMC 0,012 % 1 MΩ to 19 MΩ · CMC 0,035 % 19 MΩ to 1 GΩ · CMC 1,8 %
DC resistance
Internal procedure; At permanent location (S) L-PW-E02 based on EURAMET cg-15 v 3.0
6 Digital insulation resistance meters Calibration — DC resistance
0,1 MΩ to 1 GΩ · CMC 1,8 % 1 GΩ to 1 TΩ · CMC 2,1 %
DC resistance
Internal procedure; At permanent location (S) L-PW-E03
7 Fixed resistors
Variable resistors
Calibration — DC resistance
1 Ω to 10 Ω · CMC 0,5 % 10 Ω to 1 kΩ · CMC 0,02 % 1 kΩ to 1 MΩ · CMC 0,013% 1 MΩ to 10 MΩ · CMC 0,05 % 10 MΩ to 100 MΩ · CMC 0,19 %
DC resistance
Internal procedure; At permanent location (S) L-PW-E08 L-PW-E09
8 Electrostatic discharge (ESD) generator Calibration — High-frequency electrical quantities
test voltage — 1 kV to 2 kV · CMC 4,0 % test voltage — 2 kV to 30 kV · CMC 2,1 % rise time — 0,6 ns to 1 ns · CMC 5,8 % peak discharge current — 3 A to 124 A · CMC 6,2 % discharge current after (30 ÷ 65) ns — 2 A to 78 A · CMC 6,8 % discharge current after (65 ÷ 130) ns — 1 A to 39 A · CMC 6,4 % discharge current after (130 ÷ 800) ns — 0 A to 39 A · CMC 6,4 %
High-frequency electrical quantities
Internal procedure; At permanent location (S) L-PW-E20 based on PN-EN 61000-4-2:2011 ISO 10605:2008 + Amd 1:2014 Cor 1:2010 ISO 10605:2023
9 Electrical fast transient/burst (EFT/B) generators Calibration — High-frequency electrical quantities
peak output voltage — 0,2 kV to 5,5 kV · CMC for 50 Ω 5,3 %; for 1000 Ω 6,5 %; at the coupling output 8,0 % pulse rise time — 3 ns to 7 ns · CMC for 50 Ω 4,9 %; for 1000 Ω 6,6 %; at the coupling output 4,9 % pulse duration — 20 ns to 150 ns · CMC for 50 Ω 4,9 %; for 1000 Ω 6,2 %; at the coupling output 4,9 % burst duration — 0,1 ms to 75 ms · CMC 4,8 % pulse repetition frequency — 1 kHz to 1000 kHz · CMC 4,8 % burst period — 200 ms to 400 ms · CMC 4,8 %
High-frequency electrical quantities
Internal procedure; At permanent location (S) L-PW-E21 based on PN-EN 61000-4-4:2010 + A1:2010 PN-EN 61000-4-4:2013-05
10 Combination wave (SURGE) generators Calibration — High-frequency electrical quantities
open-circuit voltages — 0,2 kV to 7 kV · CMC 4,0 % peak short-circuit current — 0,01 kA to 3,5 kA · CMC 4,0 % rise time — 0,5 µs to 8 µs · CMC 4,5 % duration — 10 µs to 1000 µs · CMC 3,0 % front time — 0,5 µs to 15 µs · CMC 3,0 % time to half-value — 15 µs to 1000 µs · CMC 4,5 %
High-frequency electrical quantities
Internal procedure; At permanent location (S) L-PW-E22 based on PN-EN 61000-4-5:2010 PN-EN 61000-4-5:2014-10 + A1:2018-01
11 Voltage dips, short interruptions and voltage variations generators Calibration — High-frequency electrical quantities
no-load output voltage — 20 V to 600 V · CMC 4,0 % peak inrush current drive capability — 200 A to 1000 A · CMC 6,3 % instantaneous peak overshoot/undershoot — 20 V to 600 V · CMC 4,0 % rise and fall time — 1 µs to 5 µs · CMC 3,0 % phase shift — 0° to 360° · CMC 3,0 % zero-crossing control of the generator — -20° to 20° · CMC 3,0 %
High-frequency electrical quantities
Internal procedure; At permanent location (S) L-PW-E23 based on PN-EN 61000-4-11:2007 + A1:2017-09 PN-EN IEC 61000-4-11:2020-11 + AC:2020-12 + AC:2023-01
12 CDN networks Calibration — High-frequency electrical quantities
impedance magnitude (0,01 MHz to 230 MHz) — 150 Ω ±100 Ω · CMC 5% impedance phase (0,01 MHz to 230 MHz) — -30° to 90° · CMC 3° attenuation (0,01 MHz to 230 MHz) — 5 dB to 20 dB · CMC 0,5 dB
High-frequency electrical quantities
Internal procedure; At permanent location (S) L-PW-E26 based on PN-EN 61000-4-6:2024-03 PN-EN 55016-1-2:2014-09 + A1:2018-03
13 Artificial networks Calibration — High-frequency electrical quantities
impedance magnitude (9 kHz to 108 MHz) — 3 Ω to 100 Ω · CMC 6% impedance phase (9 kHz to 150 kHz) — -30° to 90° · CMC 3° impedance phase (150 kHz to 108 MHz) — -30° to 90° · CMC 2,5° voltage division factor (9 kHz to 108 MHz) — 0 dB to 10 dB · CMC 0,2 dB voltage division factor (9 kHz to 108 MHz) — 10 dB to 50 dB · CMC 0,5 dB voltage division factor (9 kHz to 108 MHz) — 50 dB to 90 dB · CMC 3,8 dB attenuation factor (9 kHz to 108 MHz) — 30 dB to 50 dB · CMC 1,0 dB attenuation factor (9 kHz to 108 MHz) — 50 dB to 80 dB · CMC 4,0 dB attenuation factor (9 kHz to 108 MHz) — 80 dB to 90 dB · CMC 5,5 dB
High-frequency electrical quantities
Internal procedure; At permanent location (S) L-PW-E27 based on PN-EN 55016-1-2:2014-09 + A1:2018-03
14 Attenuators, matching networks, adapters, RF cables Calibration — High-frequency electrical quantities
attenuation (9 kHz to 4 GHz) — 0 dB to 30 dB · CMC 0,3 dB attenuation (9 kHz to 4 GHz) — 30 dB to 60 dB · CMC 1,0 dB
High-frequency electrical quantities
Internal procedure; At permanent location (S) L-PW-E28

Reference standards (24)

EURAMET cg-15 v 3.0
ISO 10605:2008 + Amd 1:2014 Cor 1:2010
ISO 10605:2023
L-PW-E01
L-PW-E02
L-PW-E03
L-PW-E08
L-PW-E09
L-PW-E20
L-PW-E21
L-PW-E22
L-PW-E23
L-PW-E26
L-PW-E27
L-PW-E28
PN-EN 55016-1-2:2014-09 + A1:2018-03
PN-EN 61000-4-11:2007 + A1:2017-09
PN-EN 61000-4-2:2011
PN-EN 61000-4-4:2010 + A1:2010
PN-EN 61000-4-4:2013-05
PN-EN 61000-4-5:2010
PN-EN 61000-4-5:2014-10 + A1:2018-01
PN-EN 61000-4-6:2024-03
PN-EN IEC 61000-4-11:2020-11 + AC:2020-12 + AC:2023-01