🇵🇱 HAIK Sp. z o.o. PL

PCA AP 027 • Swarzędz, Poland • 13 calibration items

Metrology & calibration

HAIK Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 027 (Swarzędz, Poland). Its accreditation scope covers 13 calibration items in the following areas: Metrology & calibration. Calibrated items include: Sound level meters, Automotive exhaust gas analysers, Human-response vibration meters, Machine vibration meters (accelerometers). Most frequently used calibration principles: At permanent location (S), Internal procedure; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 027
  • Calibration items in scope: 13
  • Types of calibrated items: 9
  • Calibration principles used: 2
  • City: Swarzędz, Poland
  • Valid until: 26-09-2029
Accreditation number
AP 027
Accreditation body
PCA
Address
ul. Kórnicka 27, 62-020 Swarzędz
City
Swarzędz, Poland
Division
"HAIK" Measurement Laboratory
Valid until
26-09-2029

What this laboratory calibrates (9)

Calibration principles (2)

Certificate information

Issue date
05.09.2025
Issue no.
20
Certificate date
20.09.2019
Accreditation cycle
05.09.2025 — 26.09.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (13)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Sound level meters Calibration — Sound pressure (airborne sound)
- response of the sound level meter to the signal from a sound calibrator — 90 dB to 130 dB; relative to 20 µPa; frequency range 20 Hz to 20 kHz · CMC 0,2 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 PN-EN 61672-3:2014
2 Sound level meters Calibration — Sound pressure (airborne sound)
- response of the sound level meter to electrical test signals — 0 dB to 140 dB; relative to 20 µPa - for meters with a microphone of nominal sensitivity 50 mV/Pa · CMC 0,1 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 IEC 61672-3:2006
3 Sound level meters Calibration — Sound pressure (airborne sound)
- response of the sound level meter to electrical test signals — frequency range from 20 Hz to 20 kHz; 70 to 165 dB; relative to 20 µPa - for meters with a microphone of nominal sensitivity 4 mV/Pa · CMC 0,1 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 61672-3:2014 EN 61672-3:2013
4 Sound level meters Calibration — Sound pressure (airborne sound)
- free-field frequency response of the sound level meter — 20 Hz to 63 Hz · CMC 0,4 dB - free-field frequency response of the sound level meter — 125 Hz to 2 kHz · CMC 0,2 dB - free-field frequency response of the sound level meter — 2,5 kHz to 8 kHz · CMC 0,3 dB - free-field frequency response of the sound level meter — 10 kHz to 16 kHz · CMC 0,4 dB - free-field frequency response of the sound level meter — 20 kHz · CMC 0,8 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 60651:2002 and PN-EN 60804:2002
5 Sound level meters Calibration — Sound pressure (airborne sound)
- free-field frequency response of the sound level meter — 125 Hz · CMC 0,3 dB - free-field frequency response of the sound level meter — 1 kHz · CMC 0,3 dB - free-field frequency response of the sound level meter — 4 kHz · CMC 0,3 dB - free-field frequency response of the sound level meter — 8 kHz · CMC 0,4 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 61672-3:2007 IEC 61672-3:2006 PN-EN 61672-3:2014 EN 61672-3:2013
6 Sound calibrators Calibration — Sound pressure (airborne sound)
- sound pressure level — 90 dB to 130 dB; relative to 20 µPa, nominal frequencies: 250 Hz, 1 kHz · CMC 0,11 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 60942:2005 PN-EN 60942:2018-06 EN IEC 60942:2018
7 Octave-band and one-third-octave-band filters Calibration — Sound pressure (airborne sound)
- relative attenuation of the filters — 0 dB to 100 dB; ≤ 50 dB; Filter centre frequencies 20 Hz od 20 kHz · CMC 0,2 dB - relative attenuation of the filters — 0 dB to 100 dB; > 50 dB; Filter centre frequencies 20 Hz od 20 kHz · CMC 0,3 dB - response of the sound level meter with band-pass filters to electrical test signals — 0 dB to 145 dB; relative to 20 µPa, filter centre frequency range from 20 Hz to 20 kHz · CMC 0,2 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 61260:2000 PN-EN 61260-1:2015-01
8 Personal sound exposure meters Calibration — Sound pressure (airborne sound)
- response of the sound exposure meter to the signal from a sound calibrator — calibrator sound pressure level 90 dB to 120 dB; measurement time from 60 s to 120 s · CMC 3,90 % - response of the sound exposure meter to electrical test signals — 0,3 Pa²h to 105 Pa²h; frequency range 63 Hz to 8 kHz · CMC 3,30 % - free-field frequency response of the sound exposure meter, expressed in dB relative to 20 µPa — 63 Hz to 4 kHz · CMC 0,4 dB - free-field frequency response of the sound exposure meter, expressed in dB relative to 20 µPa — 8 kHz · CMC 0,5 dB
Sound pressure (airborne sound)
At permanent location (S) PN-EN 61252:2000 EN 61252:1995
9 Human-response vibration meters Calibration — Acceleration of mechanical vibration
- response of the meter to the reference signal for a mechanical signal — for 15,915 Hz; 1 m·s⁻² · CMC 1,8 % - response of the meter to the reference signal for a mechanical signal — for 792,580 Hz; 10 m·s⁻² · CMC 1,8 % - frequency responses of the meter for a mechanical signal for filters Wk, Wd, Wj, Wm, Wb, Wc — 0,5 Hz to 0,63 Hz · CMC 3,3 % - frequency responses of the meter for a mechanical signal for filters Wk, Wd, Wj, Wm, Wb, Wc — 0,8 Hz to 1 Hz · CMC 3,0 % - frequency responses of the meter for a mechanical signal for filters Wk, Wd, Wj, Wm, Wb, Wc — 1,25 Hz to 125 Hz · CMC 2,5 % - frequency responses of the meter for a mechanical signal for filters Wk, Wd, Wj, Wm, Wb, Wc — 160 Hz · CMC 2,7 % - frequency responses of the meter for a mechanical signal for filters Wh — 8 Hz to 20 Hz · CMC 2,5 % - frequency responses of the meter for a mechanical signal for filters Wh — 25 Hz to 500 Hz · CMC 2,2 % - frequency responses of the meter for a mechanical signal for filters Wh — 630 to 1600 Hz · CMC 2,4 % - frequency responses of the meter for a mechanical signal for filters Wh — 2000 Hz · CMC 2,5 % - determination of the linearity errors of the meter using a mechanical signal — for 15,915 Hz; 0,1 m·s⁻² to 10 m·s⁻² · CMC 2,5 % - determination of the linearity errors of the meter using a mechanical signal — for 79,58 Hz; 5 m·s⁻² to 100 m·s⁻² · CMC 2,2 % - response of the meter to electrical test signals — - linearity · CMC 1,6 %
Acceleration of mechanical vibration
At permanent location (S) PN-EN ISO 8041-1:2017 EN ISO 8041-1:2017
10 Vibration transducers Calibration — Acceleration of mechanical vibration
0,1 pC·m⁻¹·s² to 1000 pC·m⁻¹·s² · CMC 1,8 % 0,1 mV· m⁻¹·s² to 1000 mV· m⁻¹·s² · CMC 1,8 % - frequency response — 0,5 Hz to 16 Hz · CMC 2,2 % - frequency response — 20 Hz to 400 Hz · CMC 2,0 % - frequency response — 500 Hz to 1600 Hz · CMC 2,1 % - frequency response — 2000 Hz · CMC 2,2 % - frequency response — 2500 Hz to 4000 Hz · CMC 2,8 % - frequency response — 5000 Hz to 6300 Hz · CMC 3,0 % - frequency response — 8000 Hz · CMC 3,5 % - frequency response — 10000 Hz · CMC 4,0 %
Acceleration of mechanical vibration
At permanent location (S) ISO 16063-21:2003
11 Vibration calibrators Calibration — Acceleration of mechanical vibration
15 Hz to 2 kHz · CMC 1,8 %
Acceleration of mechanical vibration
Internal procedure; At permanent location (S) P-02/11 based on PN-EN ISO 8041-1:2017
12 Machine vibration meters (accelerometers) Calibration — Acceleration of mechanical vibration
- response of the meter to the reference signal for a mechanical signal — for 80 Hz; 10 m·s⁻² · CMC 2,0 % - frequency responses of the meter for a mechanical signal — 0,5 Hz to 16 Hz · CMC 2,2 % - frequency responses of the meter for a mechanical signal — 20 Hz to 400 Hz · CMC 2,0 % - frequency responses of the meter for a mechanical signal — 500 Hz to 1600 Hz · CMC 2,1 % - frequency responses of the meter for a mechanical signal — 2000 Hz · CMC 2,2 %
Acceleration of mechanical vibration
Internal procedure; At permanent location (S) P-02/11 based on ISO 16063-21:2003
13 Automotive exhaust gas analysers Calibration — Mole fraction (gas analysis)
CO — 4 mmol/mol to 6 mmol/mol · CMC 3% CO — 14 mmol/mol to 16 mmol/mol · CMC 2% CO — 29 mmol/mol to 45 mmol/mol · CMC 2% CO₂ — 48 mmol/mol to 71 mmol/mol · CMC 2% CO₂ — 88 mmol/mol to 166 mmol/mol · CMC 2% C₃H₈ — 160 mmol/mol to 240 mmol/mol · CMC 4% C₃H₈ — 540 mmol/mol to 640 mmol/mol · CMC 3% C₃H₈ — 1600 mmol/mol to 2400 mmol/mol · CMC 2%
Mole fraction (gas analysis)
Internal procedure; At permanent location (S) P-02/01

Reference standards (18)

EN 61252:1995
EN 61672-3:2013
EN IEC 60942:2018
EN ISO 8041-1:2017
IEC 61672-3:2006
ISO 16063-21:2003
P-02/01
P-02/11
PN-EN 60651:2002
PN-EN 60804:2002
PN-EN 60942:2005
PN-EN 60942:2018-06
PN-EN 61252:2000
PN-EN 61260-1:2015-01
PN-EN 61260:2000
PN-EN 61672-3:2007
PN-EN 61672-3:2014
PN-EN ISO 8041-1:2017

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20027