{"lab":{"_id":"6afa3b8b8989a133b76445ab","accr_number":"AP 027","country":"PL","imported_at":"2026-11-14T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"ul. Kórnicka 27, 62-020 Swarzędz","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"20.09.2019","city":"Swarzędz","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.","cycle_from":"05.09.2025","cycle_to":"26.09.2029","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"2.01","pl":"ciśnienie akustyczne (dźwięki w powietrzu)","en":"sound pressure (airborne sound)","de":"Schalldruck (Luftschall)","zh":"声压（空气声）","cs":"akustický tlak (zvuky ve vzduchu)"},{"codes":"2.03","pl":"przyspieszenie drgań mechanicznych","en":"acceleration of mechanical vibration","de":"Beschleunigung mechanischer Schwingungen","zh":"机械振动加速度","cs":"zrychlení mechanického kmitání"},{"codes":"3.03","pl":"ułamek molowy (analiza gazów)","en":"mole fraction (gas analysis)","de":"Stoffmengenanteil (Gasanalyse)","zh":"摩尔分数（气体分析）","cs":"látkový zlomek (analýza plynů)"}],"has_en":true,"has_zh":true,"issue":{"no":"20","date":"05.09.2025"},"issue_date":"05.09.2025","issue_number":"20","lab_division":"Laboratorium Pomiarowe \"HAIK\"","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[17.078,52.40592]},"map_coord":[52.40592,17.078],"map_geo":"nominatim-street","methods_count":13,"name":"HAIK Sp. z o.o.","parse_date":"2026-11-14T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-14T12:00:00.000Z","pdf_files":["AP_027.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: ciśnienie akustyczne (dźwięki w powietrzu), przyspieszenie drgań mechanicznych, ułamek molowy (analiza gazów). W stałej lokalizacji (S).","search_text":"haik sp. z o.o. laboratorium pomiarowe \"haik\" ul. kórnicka 27, 62-020 swarzędz laboratorium wzorcujące. wielkości mierzone: ciśnienie akustyczne (dźwięki w powietrzu), przyspieszenie drgań mechanicznych, ułamek molowy (analiza gazów). w stałej lokalizacji (s). ap 027 ap027 laboratorium wzorcujące wzorcowanie kalibracja sound pressure (airborne sound) acceleration of mechanical vibration mole fraction (gas analysis) haik sp. z o.o. laboratorium pomiarowe \"haik\" ul. kornicka 27, 62-020 swarzedz laboratorium wzorcujace. wielkosci mierzone: cisnienie akustyczne (dzwieki w powietrzu), przyspieszenie drgan mechanicznych, ulamek molowy (analiza gazow). w stalej lokalizacji (s). ap 027 ap027 laboratorium wzorcujace wzorcowanie kalibracja sound pressure (airborne sound) acceleration of mechanical vibration mole fraction (gas analysis)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20027,podmiot.html","source_pdf_sha256":"22845436cf8c94cb72fccc9e25ac6caa8ee894356fbf6fc504fb55747fd367ab","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/14/6ccf939f40332fa94eca2696f957e16f/AP%20027.pdf","status":"active","updated_at":"2026-11-14T12:00:00.000Z","valid_from":"27-09-2001","valid_until":"26-09-2029","website":"www.analizatory.info.pl","lab_division_en":"\"HAIK\" Measurement Laboratory","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"lab_division_de":"Messlabor \"HAIK\"","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","lab_division_zh":"\"HAIK\"测量实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"lab_division_cs":"Měřicí laboratoř \"HAIK\"","pelny_cs":true},"methods":[{"_id":"39988ba6561b9bdb2f2683de","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Mierniki poziomu dźwięku","test_object_en":"Sound level meters","methodology":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)","methodology_en":"Calibration — Sound pressure (airborne sound)","parameters":[{"name":"- odpowiedź miernika poziomu dźwięku na sygnał z kalibratora akustycznego","range":"90 dB do 130 dB; w odniesieniu do 20 µPa; zakres częstotliwości 20 Hz do 20 kHz","cmc":"0,2 dB"}],"parameters_en":[{"name":"- response of the sound level meter to the signal from a sound calibrator","range":"90 dB to 130 dB; relative to 20 µPa; frequency range 20 Hz to 20 kHz","cmc":"0,2 dB"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\n- odpowiedź miernika poziomu dźwięku na sygnał z kalibratora akustycznego 90 dB do 130 dB; w odniesieniu do 20 µPa; zakres częstotliwości 20 Hz do 20 kHz CMC 0,2 dB\nW stałej lokalizacji (S)","reference":"PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 PN-EN 61672-3:2014","norm_bases":["PN-EN 60651:2002","PN-EN 60804:2002","PN-EN 61672-3:2007","PN-EN 61672-3:2014"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie akustyczne (dźwięki w powietrzu)","regulatory_area_en":"Sound pressure (airborne sound)","outside_premises":false,"location_of_activity":"S","note":"Pracownia Akustyki, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Acoustics Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Mierniki poziomu dźwięku Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\n- odpowiedź miernika poziomu dźwięku na sygnał z kalibratora akustycznego 90 dB do 130 dB; w odniesieniu do 20 µPa; zakres częstotliwości 20 Hz do 20 kHz CMC 0,2 dB\nW stałej lokalizacji (S) PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 PN-EN 61672-3:2014 Mierniki poziomu dzwieku Wzorcowanie — Cisnienie akustyczne (dzwieki w powietrzu)\n- odpowiedz miernika poziomu dzwieku na sygnal z kalibratora akustycznego 90 dB do 130 dB; w odniesieniu do 20 µPa; zakres czestotliwosci 20 Hz do 20 kHz CMC 0,2 dB\nW stalej lokalizacji (S) PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 PN-EN 61672-3:2014","search_en":"Sound level meters Calibration — Sound pressure (airborne sound) At permanent location (S) Sound pressure (airborne sound) At permanent location (S) - response of the sound level meter to the signal from a sound calibrator PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 PN-EN 61672-3:2014","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Schalldruck (Luftschall)","parameters_de":[{"name":"- Reaktion des Schallpegelmessers auf das Signal eines Schallkalibrators","range":"90 dB to 130 dB; relative to 20 µPa; frequency range 20 Hz to 20 kHz","cmc":"0,2 dB"}],"regulatory_area_de":"Schalldruck (Luftschall)","search_de":"Schallpegelmesser Kalibrierung — Schalldruck (Luftschall) Am festen Standort (S) Schalldruck (Luftschall) Am festen Standort (S) - Reaktion des Schallpegelmessers auf das Signal eines Schallkalibrators PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 PN-EN 61672-3:2014","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Schallpegelmesser","methodology_zh":"校准 — 声压（空气中声音）","parameters_zh":[{"name":"- 声级计对声校准器信号的响应","range":"90 dB to 130 dB; relative to 20 µPa; frequency range 20 Hz to 20 kHz","cmc":"0,2 dB"}],"regulatory_area_zh":"声压（空气中声音）","search_zh":"声级计 校准 — 声压（空气中声音） 在固定地点 (S) 声压（空气中声音） 在固定地点 (S) - 声级计对声校准器信号的响应 PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 PN-EN 61672-3:2014","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"声级计","methodology_cs":"Kalibrace — Akustický tlak (zvuk ve vzduchu)","parameters_cs":[{"name":"- odezva zvukoměru na signál z akustického kalibrátoru","range":"90 dB to 130 dB; relative to 20 µPa; frequency range 20 Hz to 20 kHz","cmc":"0,2 dB"}],"regulatory_area_cs":"Akustický tlak (zvuk ve vzduchu)","search_cs":"Zvukoměry Kalibrace — Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) - odezva zvukoměru na signál z akustického kalibrátoru PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 PN-EN 61672-3:2014","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Zvukoměry"},{"_id":"407d3c665e9188a3e9cb1a85","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Mierniki poziomu dźwięku","test_object_en":"Sound level meters","methodology":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)","methodology_en":"Calibration — Sound pressure (airborne sound)","parameters":[{"name":"- odpowiedź miernika poziomu dźwięku na elektryczne sygnały pomiarowe","range":"0 dB do 140 dB; w odniesieniu do 20 µPa - dla mierników z mikrofonem o skuteczności nominalnej 50 mV/Pa","cmc":"0,1 dB"}],"parameters_en":[{"name":"- response of the sound level meter to electrical test signals","range":"0 dB to 140 dB; relative to 20 µPa - for meters with a microphone of nominal sensitivity 50 mV/Pa","cmc":"0,1 dB"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\n- odpowiedź miernika poziomu dźwięku na elektryczne sygnały pomiarowe 0 dB do 140 dB; w odniesieniu do 20 µPa - dla mierników z mikrofonem o skuteczności nominalnej 50 mV/Pa CMC 0,1 dB\nW stałej lokalizacji (S)","reference":"PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 IEC 61672-3:2006","norm_bases":["PN-EN 60651:2002","PN-EN 60804:2002","PN-EN 61672-3:2007","IEC 61672-3:2006"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie akustyczne (dźwięki w powietrzu)","regulatory_area_en":"Sound pressure (airborne sound)","outside_premises":false,"location_of_activity":"S","note":"Pracownia Akustyki, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Acoustics Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Mierniki poziomu dźwięku Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\n- odpowiedź miernika poziomu dźwięku na elektryczne sygnały pomiarowe 0 dB do 140 dB; w odniesieniu do 20 µPa - dla mierników z mikrofonem o skuteczności nominalnej 50 mV/Pa CMC 0,1 dB\nW stałej lokalizacji (S) PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 IEC 61672-3:2006 Mierniki poziomu dzwieku Wzorcowanie — Cisnienie akustyczne (dzwieki w powietrzu)\n- odpowiedz miernika poziomu dzwieku na elektryczne sygnaly pomiarowe 0 dB do 140 dB; w odniesieniu do 20 µPa - dla miernikow z mikrofonem o skutecznosci nominalnej 50 mV/Pa CMC 0,1 dB\nW stalej lokalizacji (S) PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 IEC 61672-3:2006","search_en":"Sound level meters Calibration — Sound pressure (airborne sound) At permanent location (S) Sound pressure (airborne sound) At permanent location (S) - response of the sound level meter to electrical test signals PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 IEC 61672-3:2006","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Schalldruck (Luftschall)","parameters_de":[{"name":"- Reaktion des Schallpegelmessers auf elektrische Prüfsignale","range":"0 dB to 140 dB; relative to 20 µPa - for meters with a microphone of nominal sensitivity 50 mV/Pa","cmc":"0,1 dB"}],"regulatory_area_de":"Schalldruck (Luftschall)","search_de":"Schallpegelmesser Kalibrierung — Schalldruck (Luftschall) Am festen Standort (S) Schalldruck (Luftschall) Am festen Standort (S) - Reaktion des Schallpegelmessers auf elektrische Prüfsignale PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 IEC 61672-3:2006","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Schallpegelmesser","methodology_zh":"校准 — 声压（空气中声音）","parameters_zh":[{"name":"- 声级计对电测试信号的响应","range":"0 dB to 140 dB; relative to 20 µPa - for meters with a microphone of nominal sensitivity 50 mV/Pa","cmc":"0,1 dB"}],"regulatory_area_zh":"声压（空气中声音）","search_zh":"声级计 校准 — 声压（空气中声音） 在固定地点 (S) 声压（空气中声音） 在固定地点 (S) - 声级计对电测试信号的响应 PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 IEC 61672-3:2006","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"声级计","methodology_cs":"Kalibrace — Akustický tlak (zvuk ve vzduchu)","parameters_cs":[{"name":"- odezva zvukoměru na elektrické měřicí signály","range":"0 dB to 140 dB; relative to 20 µPa - for meters with a microphone of nominal sensitivity 50 mV/Pa","cmc":"0,1 dB"}],"regulatory_area_cs":"Akustický tlak (zvuk ve vzduchu)","search_cs":"Zvukoměry Kalibrace — Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) - odezva zvukoměru na elektrické měřicí signály PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-3:2007 IEC 61672-3:2006","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Zvukoměry"},{"_id":"08d80c7a3bbaebfa515b153c","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Mierniki poziomu dźwięku","test_object_en":"Sound level meters","methodology":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)","methodology_en":"Calibration — Sound pressure (airborne sound)","parameters":[{"name":"- odpowiedź miernika poziomu dźwięku na elektryczne sygnały pomiarowe","range":"zakres częstotliwości od 20 Hz do 20 kHz; 70 do 165 dB; w odniesieniu do 20 µPa - dla mierników z mikrofonem o skuteczności nominalnej 4 mV/Pa","cmc":"0,1 dB"}],"parameters_en":[{"name":"- response of the sound level meter to electrical test signals","range":"frequency range from 20 Hz to 20 kHz; 70 to 165 dB; relative to 20 µPa - for meters with a microphone of nominal sensitivity 4 mV/Pa","cmc":"0,1 dB"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\n- odpowiedź miernika poziomu dźwięku na elektryczne sygnały pomiarowe zakres częstotliwości od 20 Hz do 20 kHz; 70 do 165 dB; w odniesieniu do 20 µPa - dla mierników z mikrofonem o skuteczności nominalnej 4 mV/Pa CMC 0,1 dB\nW stałej lokalizacji (S)","reference":"PN-EN 61672-3:2014 EN 61672-3:2013","norm_bases":["PN-EN 61672-3:2014","EN 61672-3:2013"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie akustyczne (dźwięki w powietrzu)","regulatory_area_en":"Sound pressure (airborne sound)","outside_premises":false,"location_of_activity":"S","note":"Pracownia Akustyki, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Acoustics Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Mierniki poziomu dźwięku Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\n- odpowiedź miernika poziomu dźwięku na elektryczne sygnały pomiarowe zakres częstotliwości od 20 Hz do 20 kHz; 70 do 165 dB; w odniesieniu do 20 µPa - dla mierników z mikrofonem o skuteczności nominalnej 4 mV/Pa CMC 0,1 dB\nW stałej lokalizacji (S) PN-EN 61672-3:2014 EN 61672-3:2013 Mierniki poziomu dzwieku Wzorcowanie — Cisnienie akustyczne (dzwieki w powietrzu)\n- odpowiedz miernika poziomu dzwieku na elektryczne sygnaly pomiarowe zakres czestotliwosci od 20 Hz do 20 kHz; 70 do 165 dB; w odniesieniu do 20 µPa - dla miernikow z mikrofonem o skutecznosci nominalnej 4 mV/Pa CMC 0,1 dB\nW stalej lokalizacji (S) PN-EN 61672-3:2014 EN 61672-3:2013","search_en":"Sound level meters Calibration — Sound pressure (airborne sound) At permanent location (S) Sound pressure (airborne sound) At permanent location (S) - response of the sound level meter to electrical test signals PN-EN 61672-3:2014 EN 61672-3:2013","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Schalldruck (Luftschall)","parameters_de":[{"name":"- Reaktion des Schallpegelmessers auf elektrische Prüfsignale","range":"frequency range from 20 Hz to 20 kHz; 70 to 165 dB; relative to 20 µPa - for meters with a microphone of nominal sensitivity 4 mV/Pa","cmc":"0,1 dB"}],"regulatory_area_de":"Schalldruck (Luftschall)","search_de":"Schallpegelmesser Kalibrierung — Schalldruck (Luftschall) Am festen Standort (S) Schalldruck (Luftschall) Am festen Standort (S) - Reaktion des Schallpegelmessers auf elektrische Prüfsignale PN-EN 61672-3:2014 EN 61672-3:2013","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Schallpegelmesser","methodology_zh":"校准 — 声压（空气中声音）","parameters_zh":[{"name":"- 声级计对电测试信号的响应","range":"frequency range from 20 Hz to 20 kHz; 70 to 165 dB; relative to 20 µPa - for meters with a microphone of nominal sensitivity 4 mV/Pa","cmc":"0,1 dB"}],"regulatory_area_zh":"声压（空气中声音）","search_zh":"声级计 校准 — 声压（空气中声音） 在固定地点 (S) 声压（空气中声音） 在固定地点 (S) - 声级计对电测试信号的响应 PN-EN 61672-3:2014 EN 61672-3:2013","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"声级计","methodology_cs":"Kalibrace — Akustický tlak (zvuk ve vzduchu)","parameters_cs":[{"name":"- odezva zvukoměru na elektrické měřicí signály","range":"frequency range from 20 Hz to 20 kHz; 70 to 165 dB; relative to 20 µPa - for meters with a microphone of nominal sensitivity 4 mV/Pa","cmc":"0,1 dB"}],"regulatory_area_cs":"Akustický tlak (zvuk ve vzduchu)","search_cs":"Zvukoměry Kalibrace — Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) - odezva zvukoměru na elektrické měřicí signály PN-EN 61672-3:2014 EN 61672-3:2013","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Zvukoměry"},{"_id":"e0aee638ffee3743789ea1ac","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Mierniki poziomu dźwięku","test_object_en":"Sound level meters","methodology":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)","methodology_en":"Calibration — Sound pressure (airborne sound)","parameters":[{"name":"- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym","range":"20 Hz do 63 Hz","cmc":"0,4 dB"},{"name":"- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym","range":"125 Hz do 2 kHz","cmc":"0,2 dB"},{"name":"- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym","range":"2,5 kHz do 8 kHz","cmc":"0,3 dB"},{"name":"- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym","range":"10 kHz do 16 kHz","cmc":"0,4 dB"},{"name":"- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym","range":"20 kHz","cmc":"0,8 dB"}],"parameters_en":[{"name":"- free-field frequency response of the sound level meter","range":"20 Hz to 63 Hz","cmc":"0,4 dB"},{"name":"- free-field frequency response of the sound level meter","range":"125 Hz to 2 kHz","cmc":"0,2 dB"},{"name":"- free-field frequency response of the sound level meter","range":"2,5 kHz to 8 kHz","cmc":"0,3 dB"},{"name":"- free-field frequency response of the sound level meter","range":"10 kHz to 16 kHz","cmc":"0,4 dB"},{"name":"- free-field frequency response of the sound level meter","range":"20 kHz","cmc":"0,8 dB"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\nZakres:\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 20 Hz do 63 Hz CMC 0,4 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 125 Hz do 2 kHz CMC 0,2 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 2,5 kHz do 8 kHz CMC 0,3 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 10 kHz do 16 kHz CMC 0,4 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 20 kHz CMC 0,8 dB\nW stałej lokalizacji (S)","reference":"PN-EN 60651:2002 i PN-EN 60804:2002","norm_bases":["PN-EN 60651:2002","PN-EN 60804:2002"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie akustyczne (dźwięki w powietrzu)","regulatory_area_en":"Sound pressure (airborne sound)","outside_premises":false,"location_of_activity":"S","note":"Pracownia Akustyki, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Acoustics Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Mierniki poziomu dźwięku Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\nZakres:\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 20 Hz do 63 Hz CMC 0,4 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 125 Hz do 2 kHz CMC 0,2 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 2,5 kHz do 8 kHz CMC 0,3 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 10 kHz do 16 kHz CMC 0,4 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 20 kHz CMC 0,8 dB\nW stałej lokalizacji (S) PN-EN 60651:2002 i PN-EN 60804:2002 Mierniki poziomu dzwieku Wzorcowanie — Cisnienie akustyczne (dzwieki w powietrzu)\nZakres:\n- charakterystyka czestotliwosciowa miernika poziomu dzwieku w polu swobodnym 20 Hz do 63 Hz CMC 0,4 dB\n- charakterystyka czestotliwosciowa miernika poziomu dzwieku w polu swobodnym 125 Hz do 2 kHz CMC 0,2 dB\n- charakterystyka czestotliwosciowa miernika poziomu dzwieku w polu swobodnym 2,5 kHz do 8 kHz CMC 0,3 dB\n- charakterystyka czestotliwosciowa miernika poziomu dzwieku w polu swobodnym 10 kHz do 16 kHz CMC 0,4 dB\n- charakterystyka czestotliwosciowa miernika poziomu dzwieku w polu swobodnym 20 kHz CMC 0,8 dB\nW stalej lokalizacji (S) PN-EN 60651:2002 i PN-EN 60804:2002","search_en":"Sound level meters Calibration — Sound pressure (airborne sound) At permanent location (S) Sound pressure (airborne sound) At permanent location (S) - free-field frequency response of the sound level meter - free-field frequency response of the sound level meter - free-field frequency response of the sound level meter - free-field frequency response of the sound level meter - free-field frequency response of the sound level meter PN-EN 60651:2002 and PN-EN 60804:2002","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PN-EN 60651:2002 and PN-EN 60804:2002","methodology_de":"Kalibrierung — Schalldruck (Luftschall)","parameters_de":[{"name":"- Freifeld-Frequenzgang des Schallpegelmessers","range":"20 Hz to 63 Hz","cmc":"0,4 dB"},{"name":"- Freifeld-Frequenzgang des Schallpegelmessers","range":"125 Hz to 2 kHz","cmc":"0,2 dB"},{"name":"- Freifeld-Frequenzgang des Schallpegelmessers","range":"2,5 kHz to 8 kHz","cmc":"0,3 dB"},{"name":"- Freifeld-Frequenzgang des Schallpegelmessers","range":"10 kHz to 16 kHz","cmc":"0,4 dB"},{"name":"- Freifeld-Frequenzgang des Schallpegelmessers","range":"20 kHz","cmc":"0,8 dB"}],"reference_de":"PN-EN 60651:2002 und PN-EN 60804:2002","regulatory_area_de":"Schalldruck (Luftschall)","search_de":"Schallpegelmesser Kalibrierung — Schalldruck (Luftschall) Am festen Standort (S) Schalldruck (Luftschall) Am festen Standort (S) - Freifeld-Frequenzgang des Schallpegelmessers - Freifeld-Frequenzgang des Schallpegelmessers - Freifeld-Frequenzgang des Schallpegelmessers - Freifeld-Frequenzgang des Schallpegelmessers - Freifeld-Frequenzgang des Schallpegelmessers PN-EN 60651:2002 und PN-EN 60804:2002","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Schallpegelmesser","methodology_zh":"校准 — 声压（空气中声音）","parameters_zh":[{"name":"- 声级计的自由场频率响应","range":"20 Hz to 63 Hz","cmc":"0,4 dB"},{"name":"- 声级计的自由场频率响应","range":"125 Hz to 2 kHz","cmc":"0,2 dB"},{"name":"- 声级计的自由场频率响应","range":"2,5 kHz to 8 kHz","cmc":"0,3 dB"},{"name":"- 声级计的自由场频率响应","range":"10 kHz to 16 kHz","cmc":"0,4 dB"},{"name":"- 声级计的自由场频率响应","range":"20 kHz","cmc":"0,8 dB"}],"reference_zh":"PN-EN 60651:2002 和 PN-EN 60804:2002","regulatory_area_zh":"声压（空气中声音）","search_zh":"声级计 校准 — 声压（空气中声音） 在固定地点 (S) 声压（空气中声音） 在固定地点 (S) - 声级计的自由场频率响应 - 声级计的自由场频率响应 - 声级计的自由场频率响应 - 声级计的自由场频率响应 - 声级计的自由场频率响应 PN-EN 60651:2002 和 PN-EN 60804:2002","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"声级计","methodology_cs":"Kalibrace — Akustický tlak (zvuk ve vzduchu)","parameters_cs":[{"name":"- frekvenční charakteristika zvukoměru ve volném poli","range":"20 Hz to 63 Hz","cmc":"0,4 dB"},{"name":"- frekvenční charakteristika zvukoměru ve volném poli","range":"125 Hz to 2 kHz","cmc":"0,2 dB"},{"name":"- frekvenční charakteristika zvukoměru ve volném poli","range":"2,5 kHz to 8 kHz","cmc":"0,3 dB"},{"name":"- frekvenční charakteristika zvukoměru ve volném poli","range":"10 kHz to 16 kHz","cmc":"0,4 dB"},{"name":"- frekvenční charakteristika zvukoměru ve volném poli","range":"20 kHz","cmc":"0,8 dB"}],"reference_cs":"PN-EN 60651:2002 a PN-EN 60804:2002","regulatory_area_cs":"Akustický tlak (zvuk ve vzduchu)","search_cs":"Zvukoměry Kalibrace — Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) - frekvenční charakteristika zvukoměru ve volném poli - frekvenční charakteristika zvukoměru ve volném poli - frekvenční charakteristika zvukoměru ve volném poli - frekvenční charakteristika zvukoměru ve volném poli - frekvenční charakteristika zvukoměru ve volném poli PN-EN 60651:2002 a PN-EN 60804:2002","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Zvukoměry"},{"_id":"128e4d3c1239d41cebfcdb85","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Mierniki poziomu dźwięku","test_object_en":"Sound level meters","methodology":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)","methodology_en":"Calibration — Sound pressure (airborne sound)","parameters":[{"name":"- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym","range":"125 Hz","cmc":"0,3 dB"},{"name":"- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym","range":"1 kHz","cmc":"0,3 dB"},{"name":"- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym","range":"4 kHz","cmc":"0,3 dB"},{"name":"- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym","range":"8 kHz","cmc":"0,4 dB"}],"parameters_en":[{"name":"- free-field frequency response of the sound level meter","range":"125 Hz","cmc":"0,3 dB"},{"name":"- free-field frequency response of the sound level meter","range":"1 kHz","cmc":"0,3 dB"},{"name":"- free-field frequency response of the sound level meter","range":"4 kHz","cmc":"0,3 dB"},{"name":"- free-field frequency response of the sound level meter","range":"8 kHz","cmc":"0,4 dB"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\nZakres:\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 125 Hz CMC 0,3 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 1 kHz CMC 0,3 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 4 kHz CMC 0,3 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 8 kHz CMC 0,4 dB\nW stałej lokalizacji (S)","reference":"PN-EN 61672-3:2007 IEC 61672-3:2006 PN-EN 61672-3:2014 EN 61672-3:2013","norm_bases":["PN-EN 61672-3:2007","IEC 61672-3:2006","PN-EN 61672-3:2014","EN 61672-3:2013"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie akustyczne (dźwięki w powietrzu)","regulatory_area_en":"Sound pressure (airborne sound)","outside_premises":false,"location_of_activity":"S","note":"Pracownia Akustyki, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Acoustics Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Mierniki poziomu dźwięku Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\nZakres:\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 125 Hz CMC 0,3 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 1 kHz CMC 0,3 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 4 kHz CMC 0,3 dB\n- charakterystyka częstotliwościowa miernika poziomu dźwięku w polu swobodnym 8 kHz CMC 0,4 dB\nW stałej lokalizacji (S) PN-EN 61672-3:2007 IEC 61672-3:2006 PN-EN 61672-3:2014 EN 61672-3:2013 Mierniki poziomu dzwieku Wzorcowanie — Cisnienie akustyczne (dzwieki w powietrzu)\nZakres:\n- charakterystyka czestotliwosciowa miernika poziomu dzwieku w polu swobodnym 125 Hz CMC 0,3 dB\n- charakterystyka czestotliwosciowa miernika poziomu dzwieku w polu swobodnym 1 kHz CMC 0,3 dB\n- charakterystyka czestotliwosciowa miernika poziomu dzwieku w polu swobodnym 4 kHz CMC 0,3 dB\n- charakterystyka czestotliwosciowa miernika poziomu dzwieku w polu swobodnym 8 kHz CMC 0,4 dB\nW stalej lokalizacji (S) PN-EN 61672-3:2007 IEC 61672-3:2006 PN-EN 61672-3:2014 EN 61672-3:2013","search_en":"Sound level meters Calibration — Sound pressure (airborne sound) At permanent location (S) Sound pressure (airborne sound) At permanent location (S) - free-field frequency response of the sound level meter - free-field frequency response of the sound level meter - free-field frequency response of the sound level meter - free-field frequency response of the sound level meter PN-EN 61672-3:2007 IEC 61672-3:2006 PN-EN 61672-3:2014 EN 61672-3:2013","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Schalldruck (Luftschall)","parameters_de":[{"name":"- Freifeld-Frequenzgang des Schallpegelmessers","range":"125 Hz","cmc":"0,3 dB"},{"name":"- Freifeld-Frequenzgang des Schallpegelmessers","range":"1 kHz","cmc":"0,3 dB"},{"name":"- Freifeld-Frequenzgang des Schallpegelmessers","range":"4 kHz","cmc":"0,3 dB"},{"name":"- Freifeld-Frequenzgang des Schallpegelmessers","range":"8 kHz","cmc":"0,4 dB"}],"regulatory_area_de":"Schalldruck (Luftschall)","search_de":"Schallpegelmesser Kalibrierung — Schalldruck (Luftschall) Am festen Standort (S) Schalldruck (Luftschall) Am festen Standort (S) - Freifeld-Frequenzgang des Schallpegelmessers - Freifeld-Frequenzgang des Schallpegelmessers - Freifeld-Frequenzgang des Schallpegelmessers - Freifeld-Frequenzgang des Schallpegelmessers PN-EN 61672-3:2007 IEC 61672-3:2006 PN-EN 61672-3:2014 EN 61672-3:2013","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Schallpegelmesser","methodology_zh":"校准 — 声压（空气中声音）","parameters_zh":[{"name":"- 声级计的自由场频率响应","range":"125 Hz","cmc":"0,3 dB"},{"name":"- 声级计的自由场频率响应","range":"1 kHz","cmc":"0,3 dB"},{"name":"- 声级计的自由场频率响应","range":"4 kHz","cmc":"0,3 dB"},{"name":"- 声级计的自由场频率响应","range":"8 kHz","cmc":"0,4 dB"}],"regulatory_area_zh":"声压（空气中声音）","search_zh":"声级计 校准 — 声压（空气中声音） 在固定地点 (S) 声压（空气中声音） 在固定地点 (S) - 声级计的自由场频率响应 - 声级计的自由场频率响应 - 声级计的自由场频率响应 - 声级计的自由场频率响应 PN-EN 61672-3:2007 IEC 61672-3:2006 PN-EN 61672-3:2014 EN 61672-3:2013","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"声级计","methodology_cs":"Kalibrace — Akustický tlak (zvuk ve vzduchu)","parameters_cs":[{"name":"- frekvenční charakteristika zvukoměru ve volném poli","range":"125 Hz","cmc":"0,3 dB"},{"name":"- frekvenční charakteristika zvukoměru ve volném poli","range":"1 kHz","cmc":"0,3 dB"},{"name":"- frekvenční charakteristika zvukoměru ve volném poli","range":"4 kHz","cmc":"0,3 dB"},{"name":"- frekvenční charakteristika zvukoměru ve volném poli","range":"8 kHz","cmc":"0,4 dB"}],"regulatory_area_cs":"Akustický tlak (zvuk ve vzduchu)","search_cs":"Zvukoměry Kalibrace — Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) - frekvenční charakteristika zvukoměru ve volném poli - frekvenční charakteristika zvukoměru ve volném poli - frekvenční charakteristika zvukoměru ve volném poli - frekvenční charakteristika zvukoměru ve volném poli PN-EN 61672-3:2007 IEC 61672-3:2006 PN-EN 61672-3:2014 EN 61672-3:2013","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Zvukoměry"},{"_id":"ed5e71dd0cf34cc566f0d394","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Kalibratory akustyczne","test_object_en":"Sound calibrators","methodology":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)","methodology_en":"Calibration — Sound pressure (airborne sound)","parameters":[{"name":"- poziom ciśnienia akustycznego","range":"90 dB do 130 dB; w odniesieniu do 20 µPa, częstotliwości nominalne: 250 Hz, 1 kHz","cmc":"0,11 dB"}],"parameters_en":[{"name":"- sound pressure level","range":"90 dB to 130 dB; relative to 20 µPa, nominal frequencies: 250 Hz, 1 kHz","cmc":"0,11 dB"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\n- poziom ciśnienia akustycznego 90 dB do 130 dB; w odniesieniu do 20 µPa, częstotliwości nominalne: 250 Hz, 1 kHz CMC 0,11 dB\nW stałej lokalizacji (S)","reference":"PN-EN 60942:2005 PN-EN 60942:2018-06 EN IEC 60942:2018","norm_bases":["PN-EN 60942:2005","PN-EN 60942:2018-06","EN IEC 60942:2018"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie akustyczne (dźwięki w powietrzu)","regulatory_area_en":"Sound pressure (airborne sound)","outside_premises":false,"location_of_activity":"S","note":"Pracownia Akustyki, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Acoustics Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Kalibratory akustyczne Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\n- poziom ciśnienia akustycznego 90 dB do 130 dB; w odniesieniu do 20 µPa, częstotliwości nominalne: 250 Hz, 1 kHz CMC 0,11 dB\nW stałej lokalizacji (S) PN-EN 60942:2005 PN-EN 60942:2018-06 EN IEC 60942:2018 Kalibratory akustyczne Wzorcowanie — Cisnienie akustyczne (dzwieki w powietrzu)\n- poziom cisnienia akustycznego 90 dB do 130 dB; w odniesieniu do 20 µPa, czestotliwosci nominalne: 250 Hz, 1 kHz CMC 0,11 dB\nW stalej lokalizacji (S) PN-EN 60942:2005 PN-EN 60942:2018-06 EN IEC 60942:2018","search_en":"Sound calibrators Calibration — Sound pressure (airborne sound) At permanent location (S) Sound pressure (airborne sound) At permanent location (S) - sound pressure level PN-EN 60942:2005 PN-EN 60942:2018-06 EN IEC 60942:2018","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Schalldruck (Luftschall)","parameters_de":[{"name":"- Schalldruckpegel","range":"90 dB to 130 dB; relative to 20 µPa, nominal frequencies: 250 Hz, 1 kHz","cmc":"0,11 dB"}],"regulatory_area_de":"Schalldruck (Luftschall)","search_de":"Schallkalibratoren Kalibrierung — Schalldruck (Luftschall) Am festen Standort (S) Schalldruck (Luftschall) Am festen Standort (S) - Schalldruckpegel PN-EN 60942:2005 PN-EN 60942:2018-06 EN IEC 60942:2018","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Schallkalibratoren","methodology_zh":"校准 — 声压（空气中声音）","parameters_zh":[{"name":"- 声压级","range":"90 dB to 130 dB; relative to 20 µPa, nominal frequencies: 250 Hz, 1 kHz","cmc":"0,11 dB"}],"regulatory_area_zh":"声压（空气中声音）","search_zh":"声校准器 校准 — 声压（空气中声音） 在固定地点 (S) 声压（空气中声音） 在固定地点 (S) - 声压级 PN-EN 60942:2005 PN-EN 60942:2018-06 EN IEC 60942:2018","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"声校准器","methodology_cs":"Kalibrace — Akustický tlak (zvuk ve vzduchu)","parameters_cs":[{"name":"- hladina akustického tlaku","range":"90 dB to 130 dB; relative to 20 µPa, nominal frequencies: 250 Hz, 1 kHz","cmc":"0,11 dB"}],"regulatory_area_cs":"Akustický tlak (zvuk ve vzduchu)","search_cs":"Akustické kalibrátory Kalibrace — Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) - hladina akustického tlaku PN-EN 60942:2005 PN-EN 60942:2018-06 EN IEC 60942:2018","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Akustické kalibrátory"},{"_id":"4a1406ef573ee44c8615f425","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Filtry pasmowe o szerokości oktawy i 1/3 oktawy","test_object_en":"Octave-band and one-third-octave-band filters","methodology":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)","methodology_en":"Calibration — Sound pressure (airborne sound)","parameters":[{"name":"- tłumienie względne filtrów","range":"0 dB do 100 dB; ≤ 50 dB; Częstotliwości środkowe filtrów 20 Hz od 20 kHz","cmc":"0,2 dB"},{"name":"- tłumienie względne filtrów","range":"0 dB do 100 dB; > 50 dB; Częstotliwości środkowe filtrów 20 Hz od 20 kHz","cmc":"0,3 dB"},{"name":"- odpowiedź miernika poziomu dźwięku z filtrami pasmowymi na elektryczne sygnały pomiarowe","range":"0 dB do 145 dB; w odniesieniu do 20 µPa, zakres częstotliwości środkowych filtrów od 20 Hz do 20 kHz","cmc":"0,2 dB"}],"parameters_en":[{"name":"- relative attenuation of the filters","range":"0 dB to 100 dB; ≤ 50 dB; Filter centre frequencies 20 Hz od 20 kHz","cmc":"0,2 dB"},{"name":"- relative attenuation of the filters","range":"0 dB to 100 dB; > 50 dB; Filter centre frequencies 20 Hz od 20 kHz","cmc":"0,3 dB"},{"name":"- response of the sound level meter with band-pass filters to electrical test signals","range":"0 dB to 145 dB; relative to 20 µPa, filter centre frequency range from 20 Hz to 20 kHz","cmc":"0,2 dB"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\nZakres:\n- tłumienie względne filtrów 0 dB do 100 dB; ≤ 50 dB; Częstotliwości środkowe filtrów 20 Hz od 20 kHz CMC 0,2 dB\n- tłumienie względne filtrów 0 dB do 100 dB; > 50 dB; Częstotliwości środkowe filtrów 20 Hz od 20 kHz CMC 0,3 dB\n- odpowiedź miernika poziomu dźwięku z filtrami pasmowymi na elektryczne sygnały pomiarowe 0 dB do 145 dB; w odniesieniu do 20 µPa, zakres częstotliwości środkowych filtrów od 20 Hz do 20 kHz CMC 0,2 dB\nW stałej lokalizacji (S)","reference":"PN-EN 61260:2000 PN-EN 61260-1:2015-01","norm_bases":["PN-EN 61260:2000","PN-EN 61260-1:2015-01"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie akustyczne (dźwięki w powietrzu)","regulatory_area_en":"Sound pressure (airborne sound)","outside_premises":false,"location_of_activity":"S","note":"Pracownia Akustyki, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Acoustics Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Filtry pasmowe o szerokości oktawy i 1/3 oktawy Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\nZakres:\n- tłumienie względne filtrów 0 dB do 100 dB; ≤ 50 dB; Częstotliwości środkowe filtrów 20 Hz od 20 kHz CMC 0,2 dB\n- tłumienie względne filtrów 0 dB do 100 dB; > 50 dB; Częstotliwości środkowe filtrów 20 Hz od 20 kHz CMC 0,3 dB\n- odpowiedź miernika poziomu dźwięku z filtrami pasmowymi na elektryczne sygnały pomiarowe 0 dB do 145 dB; w odniesieniu do 20 µPa, zakres częstotliwości środkowych filtrów od 20 Hz do 20 kHz CMC 0,2 dB\nW stałej lokalizacji (S) PN-EN 61260:2000 PN-EN 61260-1:2015-01 Filtry pasmowe o szerokosci oktawy i 1/3 oktawy Wzorcowanie — Cisnienie akustyczne (dzwieki w powietrzu)\nZakres:\n- tlumienie wzgledne filtrow 0 dB do 100 dB; ≤ 50 dB; Czestotliwosci srodkowe filtrow 20 Hz od 20 kHz CMC 0,2 dB\n- tlumienie wzgledne filtrow 0 dB do 100 dB; > 50 dB; Czestotliwosci srodkowe filtrow 20 Hz od 20 kHz CMC 0,3 dB\n- odpowiedz miernika poziomu dzwieku z filtrami pasmowymi na elektryczne sygnaly pomiarowe 0 dB do 145 dB; w odniesieniu do 20 µPa, zakres czestotliwosci srodkowych filtrow od 20 Hz do 20 kHz CMC 0,2 dB\nW stalej lokalizacji (S) PN-EN 61260:2000 PN-EN 61260-1:2015-01","search_en":"Octave-band and one-third-octave-band filters Calibration — Sound pressure (airborne sound) At permanent location (S) Sound pressure (airborne sound) At permanent location (S) - relative attenuation of the filters - relative attenuation of the filters - response of the sound level meter with band-pass filters to electrical test signals PN-EN 61260:2000 PN-EN 61260-1:2015-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Schalldruck (Luftschall)","parameters_de":[{"name":"- relative Dämpfung der Filter","range":"0 dB to 100 dB; ≤ 50 dB; Filter centre frequencies 20 Hz od 20 kHz","cmc":"0,2 dB"},{"name":"- relative Dämpfung der Filter","range":"0 dB to 100 dB; > 50 dB; Filter centre frequencies 20 Hz od 20 kHz","cmc":"0,3 dB"},{"name":"- Ansprechen des Schallpegelmessers mit Bandfiltern auf elektrische Prüfsignale","range":"0 dB to 145 dB; relative to 20 µPa, filter centre frequency range from 20 Hz to 20 kHz","cmc":"0,2 dB"}],"regulatory_area_de":"Schalldruck (Luftschall)","search_de":"Oktav- und Terzbandfilter Kalibrierung — Schalldruck (Luftschall) Am festen Standort (S) Schalldruck (Luftschall) Am festen Standort (S) - relative Dämpfung der Filter - relative Dämpfung der Filter - Ansprechen des Schallpegelmessers mit Bandfiltern auf elektrische Prüfsignale PN-EN 61260:2000 PN-EN 61260-1:2015-01","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Oktav- und Terzbandfilter","methodology_zh":"校准 — 声压（空气中声音）","parameters_zh":[{"name":"- 滤波器相对衰减","range":"0 dB to 100 dB; ≤ 50 dB; Filter centre frequencies 20 Hz od 20 kHz","cmc":"0,2 dB"},{"name":"- 滤波器相对衰减","range":"0 dB to 100 dB; > 50 dB; Filter centre frequencies 20 Hz od 20 kHz","cmc":"0,3 dB"},{"name":"- 带通滤波器声级计对电测试信号的响应","range":"0 dB to 145 dB; relative to 20 µPa, filter centre frequency range from 20 Hz to 20 kHz","cmc":"0,2 dB"}],"regulatory_area_zh":"声压（空气中声音）","search_zh":"倍频程和 1/3 倍频程带通滤波器 校准 — 声压（空气中声音） 在固定地点 (S) 声压（空气中声音） 在固定地点 (S) - 滤波器相对衰减 - 滤波器相对衰减 - 带通滤波器声级计对电测试信号的响应 PN-EN 61260:2000 PN-EN 61260-1:2015-01","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"倍频程和 1/3 倍频程带通滤波器","methodology_cs":"Kalibrace — Akustický tlak (zvuk ve vzduchu)","parameters_cs":[{"name":"- relativní útlum filtrů","range":"0 dB to 100 dB; ≤ 50 dB; Filter centre frequencies 20 Hz od 20 kHz","cmc":"0,2 dB"},{"name":"- relativní útlum filtrů","range":"0 dB to 100 dB; > 50 dB; Filter centre frequencies 20 Hz od 20 kHz","cmc":"0,3 dB"},{"name":"- odezva zvukoměru s pásmovými filtry na elektrické zkušební signály","range":"0 dB to 145 dB; relative to 20 µPa, filter centre frequency range from 20 Hz to 20 kHz","cmc":"0,2 dB"}],"regulatory_area_cs":"Akustický tlak (zvuk ve vzduchu)","search_cs":"Oktávové a třetinooktávové pásmové filtry Kalibrace — Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) - relativní útlum filtrů - relativní útlum filtrů - odezva zvukoměru s pásmovými filtry na elektrické zkušební signály PN-EN 61260:2000 PN-EN 61260-1:2015-01","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Oktávové a třetinooktávové pásmové filtry"},{"_id":"a5fcdd80c9b66fad145acb4d","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Indywidualne mierniki ekspozycji na dźwięk","test_object_en":"Personal sound exposure meters","methodology":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)","methodology_en":"Calibration — Sound pressure (airborne sound)","parameters":[{"name":"- odpowiedź miernika ekspozycji na dźwięk na sygnał z kalibratora akustycznego","range":"poziom ciśnienia akustycznego kalibratora 90 dB do 120 dB; czas pomiaru od 60 s do 120 s","cmc":"3,90 %"},{"name":"- odpowiedź miernika ekspozycji na dźwięk na elektryczne sygnały pomiarowe","range":"0,3 Pa²h do 105 Pa²h; zakres częstotliwości 63 Hz do 8 kHz","cmc":"3,30 %"},{"name":"- charakterystyka częstotliwościowa miernika ekspozycji na dźwięk w polu swobodnym, wyrażona w dB w odniesieniu do 20 µPa","range":"63 Hz do 4 kHz","cmc":"0,4 dB"},{"name":"- charakterystyka częstotliwościowa miernika ekspozycji na dźwięk w polu swobodnym, wyrażona w dB w odniesieniu do 20 µPa","range":"8 kHz","cmc":"0,5 dB"}],"parameters_en":[{"name":"- response of the sound exposure meter to the signal from a sound calibrator","range":"calibrator sound pressure level 90 dB to 120 dB; measurement time from 60 s to 120 s","cmc":"3,90 %"},{"name":"- response of the sound exposure meter to electrical test signals","range":"0,3 Pa²h to 105 Pa²h; frequency range 63 Hz to 8 kHz","cmc":"3,30 %"},{"name":"- free-field frequency response of the sound exposure meter, expressed in dB relative to 20 µPa","range":"63 Hz to 4 kHz","cmc":"0,4 dB"},{"name":"- free-field frequency response of the sound exposure meter, expressed in dB relative to 20 µPa","range":"8 kHz","cmc":"0,5 dB"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\nZakres:\n- odpowiedź miernika ekspozycji na dźwięk na sygnał z kalibratora akustycznego poziom ciśnienia akustycznego kalibratora 90 dB do 120 dB; czas pomiaru od 60 s do 120 s CMC 3,90 %\n- odpowiedź miernika ekspozycji na dźwięk na elektryczne sygnały pomiarowe 0,3 Pa²h do 105 Pa²h; zakres częstotliwości 63 Hz do 8 kHz CMC 3,30 %\n- charakterystyka częstotliwościowa miernika ekspozycji na dźwięk w polu swobodnym, wyrażona w dB w odniesieniu do 20 µPa 63 Hz do 4 kHz CMC 0,4 dB\n- charakterystyka częstotliwościowa miernika ekspozycji na dźwięk w polu swobodnym, wyrażona w dB w odniesieniu do 20 µPa 8 kHz CMC 0,5 dB\nW stałej lokalizacji (S)","reference":"PN-EN 61252:2000 EN 61252:1995","norm_bases":["PN-EN 61252:2000","EN 61252:1995"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie akustyczne (dźwięki w powietrzu)","regulatory_area_en":"Sound pressure (airborne sound)","outside_premises":false,"location_of_activity":"S","note":"Pracownia Akustyki, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Acoustics Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Indywidualne mierniki ekspozycji na dźwięk Wzorcowanie — Ciśnienie akustyczne (dźwięki w powietrzu)\nZakres:\n- odpowiedź miernika ekspozycji na dźwięk na sygnał z kalibratora akustycznego poziom ciśnienia akustycznego kalibratora 90 dB do 120 dB; czas pomiaru od 60 s do 120 s CMC 3,90 %\n- odpowiedź miernika ekspozycji na dźwięk na elektryczne sygnały pomiarowe 0,3 Pa²h do 105 Pa²h; zakres częstotliwości 63 Hz do 8 kHz CMC 3,30 %\n- charakterystyka częstotliwościowa miernika ekspozycji na dźwięk w polu swobodnym, wyrażona w dB w odniesieniu do 20 µPa 63 Hz do 4 kHz CMC 0,4 dB\n- charakterystyka częstotliwościowa miernika ekspozycji na dźwięk w polu swobodnym, wyrażona w dB w odniesieniu do 20 µPa 8 kHz CMC 0,5 dB\nW stałej lokalizacji (S) PN-EN 61252:2000 EN 61252:1995 Indywidualne mierniki ekspozycji na dzwiek Wzorcowanie — Cisnienie akustyczne (dzwieki w powietrzu)\nZakres:\n- odpowiedz miernika ekspozycji na dzwiek na sygnal z kalibratora akustycznego poziom cisnienia akustycznego kalibratora 90 dB do 120 dB; czas pomiaru od 60 s do 120 s CMC 3,90 %\n- odpowiedz miernika ekspozycji na dzwiek na elektryczne sygnaly pomiarowe 0,3 Pa²h do 105 Pa²h; zakres czestotliwosci 63 Hz do 8 kHz CMC 3,30 %\n- charakterystyka czestotliwosciowa miernika ekspozycji na dzwiek w polu swobodnym, wyrazona w dB w odniesieniu do 20 µPa 63 Hz do 4 kHz CMC 0,4 dB\n- charakterystyka czestotliwosciowa miernika ekspozycji na dzwiek w polu swobodnym, wyrazona w dB w odniesieniu do 20 µPa 8 kHz CMC 0,5 dB\nW stalej lokalizacji (S) PN-EN 61252:2000 EN 61252:1995","search_en":"Personal sound exposure meters Calibration — Sound pressure (airborne sound) At permanent location (S) Sound pressure (airborne sound) At permanent location (S) - response of the sound exposure meter to the signal from a sound calibrator - response of the sound exposure meter to electrical test signals - free-field frequency response of the sound exposure meter, expressed in dB relative to 20 µPa - free-field frequency response of the sound exposure meter, expressed in dB relative to 20 µPa PN-EN 61252:2000 EN 61252:1995","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Schalldruck (Luftschall)","parameters_de":[{"name":"- Reaktion des Schallexposimeters auf das Signal eines Schallkalibrators","range":"calibrator sound pressure level 90 dB to 120 dB; measurement time from 60 s to 120 s","cmc":"3,90 %"},{"name":"- Reaktion des Schallexposimeters auf elektrische Prüfsignale","range":"0,3 Pa²h to 105 Pa²h; frequency range 63 Hz to 8 kHz","cmc":"3,30 %"},{"name":"- Freifeld-Frequenzgang des Schallexpositionsmessers, ausgedrückt in dB bezogen auf 20 µPa","range":"63 Hz to 4 kHz","cmc":"0,4 dB"},{"name":"- Freifeld-Frequenzgang des Schallexpositionsmessers, ausgedrückt in dB bezogen auf 20 µPa","range":"8 kHz","cmc":"0,5 dB"}],"regulatory_area_de":"Schalldruck (Luftschall)","search_de":"Personen-Schallexpositionsmesser Kalibrierung — Schalldruck (Luftschall) Am festen Standort (S) Schalldruck (Luftschall) Am festen Standort (S) - Reaktion des Schallexposimeters auf das Signal eines Schallkalibrators - Reaktion des Schallexposimeters auf elektrische Prüfsignale - Freifeld-Frequenzgang des Schallexpositionsmessers, ausgedrückt in dB bezogen auf 20 µPa - Freifeld-Frequenzgang des Schallexpositionsmessers, ausgedrückt in dB bezogen auf 20 µPa PN-EN 61252:2000 EN 61252:1995","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Personen-Schallexpositionsmesser","methodology_zh":"校准 — 声压（空气中声音）","parameters_zh":[{"name":"- 声暴露计对声校准器信号的响应","range":"calibrator sound pressure level 90 dB to 120 dB; measurement time from 60 s to 120 s","cmc":"3,90 %"},{"name":"- 声暴露计对电测试信号的响应","range":"0,3 Pa²h to 105 Pa²h; frequency range 63 Hz to 8 kHz","cmc":"3,30 %"},{"name":"- 声暴露计的自由场频率响应，以dB表示，基准20 µPa","range":"63 Hz to 4 kHz","cmc":"0,4 dB"},{"name":"- 声暴露计的自由场频率响应，以dB表示，基准20 µPa","range":"8 kHz","cmc":"0,5 dB"}],"regulatory_area_zh":"声压（空气中声音）","search_zh":"个人声暴露计 校准 — 声压（空气中声音） 在固定地点 (S) 声压（空气中声音） 在固定地点 (S) - 声暴露计对声校准器信号的响应 - 声暴露计对电测试信号的响应 - 声暴露计的自由场频率响应，以dB表示，基准20 µPa - 声暴露计的自由场频率响应，以dB表示，基准20 µPa PN-EN 61252:2000 EN 61252:1995","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"个人声暴露计","methodology_cs":"Kalibrace — Akustický tlak (zvuk ve vzduchu)","parameters_cs":[{"name":"- odezva měřiče expozice hluku na signál z akustického kalibrátoru","range":"calibrator sound pressure level 90 dB to 120 dB; measurement time from 60 s to 120 s","cmc":"3,90 %"},{"name":"- odezva měřiče expozice hluku na elektrické měřicí signály","range":"0,3 Pa²h to 105 Pa²h; frequency range 63 Hz to 8 kHz","cmc":"3,30 %"},{"name":"- kmitočtová charakteristika měřiče expozice hluku ve volném poli, vyjádřená v dB vzhledem k 20 µPa","range":"63 Hz to 4 kHz","cmc":"0,4 dB"},{"name":"- kmitočtová charakteristika měřiče expozice hluku ve volném poli, vyjádřená v dB vzhledem k 20 µPa","range":"8 kHz","cmc":"0,5 dB"}],"regulatory_area_cs":"Akustický tlak (zvuk ve vzduchu)","search_cs":"Osobní měřiče expozice hluku Kalibrace — Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) Akustický tlak (zvuk ve vzduchu) Ve stálé lokalitě (S) - odezva měřiče expozice hluku na signál z akustického kalibrátoru - odezva měřiče expozice hluku na elektrické měřicí signály - kmitočtová charakteristika měřiče expozice hluku ve volném poli, vyjádřená v dB vzhledem k 20 µPa - kmitočtová charakteristika měřiče expozice hluku ve volném poli, vyjádřená v dB vzhledem k 20 µPa PN-EN 61252:2000 EN 61252:1995","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Osobní měřiče expozice hluku"},{"_id":"15bcbe62b5960585a23aaa63","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Mierniki drgań mechanicznych działających na człowieka","test_object_en":"Human-response vibration meters","methodology":"Wzorcowanie — Przyspieszenie drgań mechanicznych","methodology_en":"Calibration — Acceleration of mechanical vibration","parameters":[{"name":"- odpowiedź miernika na sygnał odniesienia dla sygnału mechanicznego","range":"dla 15,915 Hz; 1 m·s⁻²","cmc":"1,8 %"},{"name":"- odpowiedź miernika na sygnał odniesienia dla sygnału mechanicznego","range":"dla 792,580 Hz; 10 m·s⁻²","cmc":"1,8 %"},{"name":"- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wk, Wd, Wj, Wm, Wb, Wc","range":"0,5 Hz do 0,63 Hz","cmc":"3,3 %"},{"name":"- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wk, Wd, Wj, Wm, Wb, Wc","range":"0,8 Hz do 1 Hz","cmc":"3,0 %"},{"name":"- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wk, Wd, Wj, Wm, Wb, Wc","range":"1,25 Hz do 125 Hz","cmc":"2,5 %"},{"name":"- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wk, Wd, Wj, Wm, Wb, Wc","range":"160 Hz","cmc":"2,7 %"},{"name":"- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wh","range":"8 Hz do 20 Hz","cmc":"2,5 %"},{"name":"- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wh","range":"25 Hz do 500 Hz","cmc":"2,2 %"},{"name":"- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wh","range":"630 do 1600 Hz","cmc":"2,4 %"},{"name":"- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wh","range":"2000 Hz","cmc":"2,5 %"},{"name":"- wyznaczenie błędów liniowości miernika za pomocą sygnału mechanicznego","range":"dla 15,915 Hz; 0,1 m·s⁻² do 10 m·s⁻²","cmc":"2,5 %"},{"name":"- wyznaczenie błędów liniowości miernika za pomocą sygnału mechanicznego","range":"dla 79,58 Hz; 5 m·s⁻² do 100 m·s⁻²","cmc":"2,2 %"},{"name":"- odpowiedź miernika na elektryczne sygnały pomiarowe","range":"- liniowość","cmc":"1,6 %"}],"parameters_en":[{"name":"- response of the meter to the reference signal for a mechanical signal","range":"for 15,915 Hz; 1 m·s⁻²","cmc":"1,8 %"},{"name":"- response of the meter to the reference signal for a mechanical signal","range":"for 792,580 Hz; 10 m·s⁻²","cmc":"1,8 %"},{"name":"- frequency responses of the meter for a mechanical signal for filters Wk, Wd, Wj, Wm, Wb, Wc","range":"0,5 Hz to 0,63 Hz","cmc":"3,3 %"},{"name":"- frequency responses of the meter for a mechanical signal for filters Wk, Wd, Wj, Wm, Wb, Wc","range":"0,8 Hz to 1 Hz","cmc":"3,0 %"},{"name":"- frequency responses of the meter for a mechanical signal for filters Wk, Wd, Wj, Wm, Wb, Wc","range":"1,25 Hz to 125 Hz","cmc":"2,5 %"},{"name":"- frequency responses of the meter for a mechanical signal for filters Wk, Wd, Wj, Wm, Wb, Wc","range":"160 Hz","cmc":"2,7 %"},{"name":"- frequency responses of the meter for a mechanical signal for filters Wh","range":"8 Hz to 20 Hz","cmc":"2,5 %"},{"name":"- frequency responses of the meter for a mechanical signal for filters Wh","range":"25 Hz to 500 Hz","cmc":"2,2 %"},{"name":"- frequency responses of the meter for a mechanical signal for filters Wh","range":"630 to 1600 Hz","cmc":"2,4 %"},{"name":"- frequency responses of the meter for a mechanical signal for filters Wh","range":"2000 Hz","cmc":"2,5 %"},{"name":"- determination of the linearity errors of the meter using a mechanical signal","range":"for 15,915 Hz; 0,1 m·s⁻² to 10 m·s⁻²","cmc":"2,5 %"},{"name":"- determination of the linearity errors of the meter using a mechanical signal","range":"for 79,58 Hz; 5 m·s⁻² to 100 m·s⁻²","cmc":"2,2 %"},{"name":"- response of the meter to electrical test signals","range":"- linearity","cmc":"1,6 %"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Przyspieszenie drgań mechanicznych\nZakres:\n- odpowiedź miernika na sygnał odniesienia dla sygnału mechanicznego dla 15,915 Hz; 1 m·s⁻² CMC 1,8 %\n- odpowiedź miernika na sygnał odniesienia dla sygnału mechanicznego dla 792,580 Hz; 10 m·s⁻² CMC 1,8 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wk, Wd, Wj, Wm, Wb, Wc 0,5 Hz do 0,63 Hz CMC 3,3 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wk, Wd, Wj, Wm, Wb, Wc 0,8 Hz do 1 Hz CMC 3,0 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wk, Wd, Wj, Wm, Wb, Wc 1,25 Hz do 125 Hz CMC 2,5 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wk, Wd, Wj, Wm, Wb, Wc 160 Hz CMC 2,7 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wh 8 Hz do 20 Hz CMC 2,5 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wh 25 Hz do 500 Hz CMC 2,2 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wh 630 do 1600 Hz CMC 2,4 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wh 2000 Hz CMC 2,5 %\n- wyznaczenie błędów liniowości miernika za pomocą sygnału mechanicznego dla 15,915 Hz; 0,1 m·s⁻² do 10 m·s⁻² CMC 2,5 %\n- wyznaczenie błędów liniowości miernika za pomocą sygnału mechanicznego dla 79,58 Hz; 5 m·s⁻² do 100 m·s⁻² CMC 2,2 %\n- odpowiedź miernika na elektryczne sygnały pomiarowe - liniowość CMC 1,6 %\nW stałej lokalizacji (S)","reference":"PN-EN ISO 8041-1:2017 EN ISO 8041-1:2017","norm_bases":["PN-EN ISO 8041-1:2017","EN ISO 8041-1:2017"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Przyspieszenie drgań mechanicznych","regulatory_area_en":"Acceleration of mechanical vibration","outside_premises":false,"location_of_activity":"S","note":"Pracownia Akustyki, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Acoustics Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Mierniki drgań mechanicznych działających na człowieka Wzorcowanie — Przyspieszenie drgań mechanicznych\nZakres:\n- odpowiedź miernika na sygnał odniesienia dla sygnału mechanicznego dla 15,915 Hz; 1 m·s⁻² CMC 1,8 %\n- odpowiedź miernika na sygnał odniesienia dla sygnału mechanicznego dla 792,580 Hz; 10 m·s⁻² CMC 1,8 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wk, Wd, Wj, Wm, Wb, Wc 0,5 Hz do 0,63 Hz CMC 3,3 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wk, Wd, Wj, Wm, Wb, Wc 0,8 Hz do 1 Hz CMC 3,0 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wk, Wd, Wj, Wm, Wb, Wc 1,25 Hz do 125 Hz CMC 2,5 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wk, Wd, Wj, Wm, Wb, Wc 160 Hz CMC 2,7 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wh 8 Hz do 20 Hz CMC 2,5 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wh 25 Hz do 500 Hz CMC 2,2 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wh 630 do 1600 Hz CMC 2,4 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego dla filtrów Wh 2000 Hz CMC 2,5 %\n- wyznaczenie błędów liniowości miernika za pomocą sygnału mechanicznego dla 15,915 Hz; 0,1 m·s⁻² do 10 m·s⁻² CMC 2,5 %\n- wyznaczenie błędów liniowości miernika za pomocą sygnału mechanicznego dla 79,58 Hz; 5 m·s⁻² do 100 m·s⁻² CMC 2,2 %\n- odpowiedź miernika na elektryczne sygnały pomiarowe - liniowość CMC 1,6 %\nW stałej lokalizacji (S) PN-EN ISO 8041-1:2017 EN ISO 8041-1:2017 Mierniki drgan mechanicznych dzialajacych na czlowieka Wzorcowanie — Przyspieszenie drgan mechanicznych\nZakres:\n- odpowiedz miernika na sygnal odniesienia dla sygnalu mechanicznego dla 15,915 Hz; 1 m·s⁻² CMC 1,8 %\n- odpowiedz miernika na sygnal odniesienia dla sygnalu mechanicznego dla 792,580 Hz; 10 m·s⁻² CMC 1,8 %\n- charakterystyki czestotliwosciowe miernika dla sygnalu mechanicznego dla filtrow Wk, Wd, Wj, Wm, Wb, Wc 0,5 Hz do 0,63 Hz CMC 3,3 %\n- charakterystyki czestotliwosciowe miernika dla sygnalu mechanicznego dla filtrow Wk, Wd, Wj, Wm, Wb, Wc 0,8 Hz do 1 Hz CMC 3,0 %\n- charakterystyki czestotliwosciowe miernika dla sygnalu mechanicznego dla filtrow Wk, Wd, Wj, Wm, Wb, Wc 1,25 Hz do 125 Hz CMC 2,5 %\n- charakterystyki czestotliwosciowe miernika dla sygnalu mechanicznego dla filtrow Wk, Wd, Wj, Wm, Wb, Wc 160 Hz CMC 2,7 %\n- charakterystyki czestotliwosciowe miernika dla sygnalu mechanicznego dla filtrow Wh 8 Hz do 20 Hz CMC 2,5 %\n- charakterystyki czestotliwosciowe miernika dla sygnalu mechanicznego dla filtrow Wh 25 Hz do 500 Hz CMC 2,2 %\n- charakterystyki czestotliwosciowe miernika dla sygnalu mechanicznego dla filtrow Wh 630 do 1600 Hz CMC 2,4 %\n- charakterystyki czestotliwosciowe miernika dla sygnalu mechanicznego dla filtrow Wh 2000 Hz CMC 2,5 %\n- wyznaczenie bledow liniowosci miernika za pomoca sygnalu mechanicznego dla 15,915 Hz; 0,1 m·s⁻² do 10 m·s⁻² CMC 2,5 %\n- wyznaczenie bledow liniowosci miernika za pomoca sygnalu mechanicznego dla 79,58 Hz; 5 m·s⁻² do 100 m·s⁻² CMC 2,2 %\n- odpowiedz miernika na elektryczne sygnaly pomiarowe - liniowosc CMC 1,6 %\nW stalej lokalizacji (S) PN-EN ISO 8041-1:2017 EN ISO 8041-1:2017","search_en":"Human-response vibration meters Calibration — Acceleration of mechanical vibration At permanent location (S) Acceleration of mechanical vibration At permanent location (S) - response of the meter to the reference signal for a mechanical signal - response of the meter to the reference signal for a mechanical signal - frequency responses of the meter for a mechanical signal for filters Wk, Wd, Wj, Wm, Wb, Wc - frequency responses of the meter for a mechanical signal for filters Wk, Wd, Wj, Wm, Wb, Wc - frequency responses of the meter for a mechanical signal for filters Wk, Wd, Wj, Wm, Wb, Wc - frequency responses of the meter for a mechanical signal for filters Wk, Wd, Wj, Wm, Wb, Wc - frequency responses of the meter for a mechanical signal for filters Wh - frequency responses of the meter for a mechanical signal for filters Wh - frequency responses of the meter for a mechanical signal for filters Wh - frequency responses of the meter for a mechanical signal for filters Wh - determination of the linearity errors of the meter using a mechanical signal - determination of the linearity errors of the meter using a mechanical signal - response of the meter to electrical test signals PN-EN ISO 8041-1:2017 EN ISO 8041-1:2017","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Beschleunigung mechanischer Schwingungen","parameters_de":[{"name":"- Reaktion des Messgeräts auf das Bezugssignal für ein mechanisches Signal","range":"for 15,915 Hz; 1 m·s⁻²","cmc":"1,8 %"},{"name":"- Reaktion des Messgeräts auf das Bezugssignal für ein mechanisches Signal","range":"for 792,580 Hz; 10 m·s⁻²","cmc":"1,8 %"},{"name":"- Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wk, Wd, Wj, Wm, Wb, Wc","range":"0,5 Hz to 0,63 Hz","cmc":"3,3 %"},{"name":"- Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wk, Wd, Wj, Wm, Wb, Wc","range":"0,8 Hz to 1 Hz","cmc":"3,0 %"},{"name":"- Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wk, Wd, Wj, Wm, Wb, Wc","range":"1,25 Hz to 125 Hz","cmc":"2,5 %"},{"name":"- Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wk, Wd, Wj, Wm, Wb, Wc","range":"160 Hz","cmc":"2,7 %"},{"name":"- Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wh","range":"8 Hz to 20 Hz","cmc":"2,5 %"},{"name":"- Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wh","range":"25 Hz to 500 Hz","cmc":"2,2 %"},{"name":"- Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wh","range":"630 to 1600 Hz","cmc":"2,4 %"},{"name":"- Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wh","range":"2000 Hz","cmc":"2,5 %"},{"name":"- Bestimmung der Linearitätsabweichungen des Messgeräts mit einem mechanischen Signal","range":"for 15,915 Hz; 0,1 m·s⁻² to 10 m·s⁻²","cmc":"2,5 %"},{"name":"- Bestimmung der Linearitätsabweichungen des Messgeräts mit einem mechanischen Signal","range":"for 79,58 Hz; 5 m·s⁻² to 100 m·s⁻²","cmc":"2,2 %"},{"name":"- Ansprechen des Messgeräts auf elektrische Prüfsignale","range":"- linearity","cmc":"1,6 %"}],"regulatory_area_de":"Beschleunigung mechanischer Schwingungen","search_de":"Messgeräte für Humanschwingungen Kalibrierung — Beschleunigung mechanischer Schwingungen Am festen Standort (S) Beschleunigung mechanischer Schwingungen Am festen Standort (S) - Reaktion des Messgeräts auf das Bezugssignal für ein mechanisches Signal - Reaktion des Messgeräts auf das Bezugssignal für ein mechanisches Signal - Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wk, Wd, Wj, Wm, Wb, Wc - Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wk, Wd, Wj, Wm, Wb, Wc - Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wk, Wd, Wj, Wm, Wb, Wc - Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wk, Wd, Wj, Wm, Wb, Wc - Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wh - Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wh - Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wh - Frequenzgänge des Messgeräts für ein mechanisches Signal für die Filter Wh - Bestimmung der Linearitätsabweichungen des Messgeräts mit einem mechanischen Signal - Bestimmung der Linearitätsabweichungen des Messgeräts mit einem mechanischen Signal - Ansprechen des Messgeräts auf elektrische Prüfsignale PN-EN ISO 8041-1:2017 EN ISO 8041-1:2017","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Messgeräte für Humanschwingungen","methodology_zh":"校准 — 机械振动加速度","parameters_zh":[{"name":"- 仪器对机械参考信号的响应","range":"for 15,915 Hz; 1 m·s⁻²","cmc":"1,8 %"},{"name":"- 仪器对机械参考信号的响应","range":"for 792,580 Hz; 10 m·s⁻²","cmc":"1,8 %"},{"name":"- 仪表对机械信号的频率响应（Wk、Wd、Wj、Wm、Wb、Wc滤波器）","range":"0,5 Hz to 0,63 Hz","cmc":"3,3 %"},{"name":"- 仪表对机械信号的频率响应（Wk、Wd、Wj、Wm、Wb、Wc滤波器）","range":"0,8 Hz to 1 Hz","cmc":"3,0 %"},{"name":"- 仪表对机械信号的频率响应（Wk、Wd、Wj、Wm、Wb、Wc滤波器）","range":"1,25 Hz to 125 Hz","cmc":"2,5 %"},{"name":"- 仪表对机械信号的频率响应（Wk、Wd、Wj、Wm、Wb、Wc滤波器）","range":"160 Hz","cmc":"2,7 %"},{"name":"- 仪表对机械信号的频率响应（Wh滤波器）","range":"8 Hz to 20 Hz","cmc":"2,5 %"},{"name":"- 仪表对机械信号的频率响应（Wh滤波器）","range":"25 Hz to 500 Hz","cmc":"2,2 %"},{"name":"- 仪表对机械信号的频率响应（Wh滤波器）","range":"630 to 1600 Hz","cmc":"2,4 %"},{"name":"- 仪表对机械信号的频率响应（Wh滤波器）","range":"2000 Hz","cmc":"2,5 %"},{"name":"- 用机械信号测定仪表线性误差","range":"for 15,915 Hz; 0,1 m·s⁻² to 10 m·s⁻²","cmc":"2,5 %"},{"name":"- 用机械信号测定仪表线性误差","range":"for 79,58 Hz; 5 m·s⁻² to 100 m·s⁻²","cmc":"2,2 %"},{"name":"- 仪表对电测试信号的响应","range":"- linearity","cmc":"1,6 %"}],"regulatory_area_zh":"机械振动加速度","search_zh":"人体振动测量仪 校准 — 机械振动加速度 在固定地点 (S) 机械振动加速度 在固定地点 (S) - 仪器对机械参考信号的响应 - 仪器对机械参考信号的响应 - 仪表对机械信号的频率响应（Wk、Wd、Wj、Wm、Wb、Wc滤波器） - 仪表对机械信号的频率响应（Wk、Wd、Wj、Wm、Wb、Wc滤波器） - 仪表对机械信号的频率响应（Wk、Wd、Wj、Wm、Wb、Wc滤波器） - 仪表对机械信号的频率响应（Wk、Wd、Wj、Wm、Wb、Wc滤波器） - 仪表对机械信号的频率响应（Wh滤波器） - 仪表对机械信号的频率响应（Wh滤波器） - 仪表对机械信号的频率响应（Wh滤波器） - 仪表对机械信号的频率响应（Wh滤波器） - 用机械信号测定仪表线性误差 - 用机械信号测定仪表线性误差 - 仪表对电测试信号的响应 PN-EN ISO 8041-1:2017 EN ISO 8041-1:2017","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"人体振动测量仪","methodology_cs":"Kalibrace — Zrychlení mechanického kmitání","parameters_cs":[{"name":"- odezva měřiče na referenční signál pro mechanický signál","range":"for 15,915 Hz; 1 m·s⁻²","cmc":"1,8 %"},{"name":"- odezva měřiče na referenční signál pro mechanický signál","range":"for 792,580 Hz; 10 m·s⁻²","cmc":"1,8 %"},{"name":"- kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wk, Wd, Wj, Wm, Wb, Wc","range":"0,5 Hz to 0,63 Hz","cmc":"3,3 %"},{"name":"- kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wk, Wd, Wj, Wm, Wb, Wc","range":"0,8 Hz to 1 Hz","cmc":"3,0 %"},{"name":"- kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wk, Wd, Wj, Wm, Wb, Wc","range":"1,25 Hz to 125 Hz","cmc":"2,5 %"},{"name":"- kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wk, Wd, Wj, Wm, Wb, Wc","range":"160 Hz","cmc":"2,7 %"},{"name":"- kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wh","range":"8 Hz to 20 Hz","cmc":"2,5 %"},{"name":"- kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wh","range":"25 Hz to 500 Hz","cmc":"2,2 %"},{"name":"- kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wh","range":"630 to 1600 Hz","cmc":"2,4 %"},{"name":"- kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wh","range":"2000 Hz","cmc":"2,5 %"},{"name":"- stanovení chyb linearity měřidla mechanickým signálem","range":"for 15,915 Hz; 0,1 m·s⁻² to 10 m·s⁻²","cmc":"2,5 %"},{"name":"- stanovení chyb linearity měřidla mechanickým signálem","range":"for 79,58 Hz; 5 m·s⁻² to 100 m·s⁻²","cmc":"2,2 %"},{"name":"- odezva měřidla na elektrické zkušební signály","range":"- linearity","cmc":"1,6 %"}],"regulatory_area_cs":"Zrychlení mechanického kmitání","search_cs":"Měřiče vibrací působících na člověka Kalibrace — Zrychlení mechanického kmitání Ve stálé lokalitě (S) Zrychlení mechanického kmitání Ve stálé lokalitě (S) - odezva měřiče na referenční signál pro mechanický signál - odezva měřiče na referenční signál pro mechanický signál - kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wk, Wd, Wj, Wm, Wb, Wc - kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wk, Wd, Wj, Wm, Wb, Wc - kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wk, Wd, Wj, Wm, Wb, Wc - kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wk, Wd, Wj, Wm, Wb, Wc - kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wh - kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wh - kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wh - kmitočtové charakteristiky měřidla pro mechanický signál pro filtry Wh - stanovení chyb linearity měřidla mechanickým signálem - stanovení chyb linearity měřidla mechanickým signálem - odezva měřidla na elektrické zkušební signály PN-EN ISO 8041-1:2017 EN ISO 8041-1:2017","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče vibrací působících na člověka"},{"_id":"bde392251cb6261bd385a2bf","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Przetworniki drgań mechanicznych","test_object_en":"Vibration transducers","methodology":"Wzorcowanie — Przyspieszenie drgań mechanicznych","methodology_en":"Calibration — Acceleration of mechanical vibration","parameters":[{"name":"","range":"0,1 pC·m⁻¹·s² do 1000 pC·m⁻¹·s²","cmc":"1,8 %"},{"name":"","range":"0,1 mV· m⁻¹·s² do 1000 mV· m⁻¹·s²","cmc":"1,8 %"},{"name":"- charakterystyka częstotliwościowa","range":"0,5 Hz do 16 Hz","cmc":"2,2 %"},{"name":"- charakterystyka częstotliwościowa","range":"20 Hz do 400 Hz","cmc":"2,0 %"},{"name":"- charakterystyka częstotliwościowa","range":"500 Hz do 1600 Hz","cmc":"2,1 %"},{"name":"- charakterystyka częstotliwościowa","range":"2000 Hz","cmc":"2,2 %"},{"name":"- charakterystyka częstotliwościowa","range":"2500 Hz do 4000 Hz","cmc":"2,8 %"},{"name":"- charakterystyka częstotliwościowa","range":"5000 Hz do 6300 Hz","cmc":"3,0 %"},{"name":"- charakterystyka częstotliwościowa","range":"8000 Hz","cmc":"3,5 %"},{"name":"- charakterystyka częstotliwościowa","range":"10000 Hz","cmc":"4,0 %"}],"parameters_en":[{"name":"","range":"0,1 pC·m⁻¹·s² to 1000 pC·m⁻¹·s²","cmc":"1,8 %"},{"name":"","range":"0,1 mV· m⁻¹·s² to 1000 mV· m⁻¹·s²","cmc":"1,8 %"},{"name":"- frequency response","range":"0,5 Hz to 16 Hz","cmc":"2,2 %"},{"name":"- frequency response","range":"20 Hz to 400 Hz","cmc":"2,0 %"},{"name":"- frequency response","range":"500 Hz to 1600 Hz","cmc":"2,1 %"},{"name":"- frequency response","range":"2000 Hz","cmc":"2,2 %"},{"name":"- frequency response","range":"2500 Hz to 4000 Hz","cmc":"2,8 %"},{"name":"- frequency response","range":"5000 Hz to 6300 Hz","cmc":"3,0 %"},{"name":"- frequency response","range":"8000 Hz","cmc":"3,5 %"},{"name":"- frequency response","range":"10000 Hz","cmc":"4,0 %"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Przyspieszenie drgań mechanicznych\nZakres:\n0,1 pC·m⁻¹·s² do 1000 pC·m⁻¹·s² CMC 1,8 %\n0,1 mV· m⁻¹·s² do 1000 mV· m⁻¹·s² CMC 1,8 %\n- charakterystyka częstotliwościowa 0,5 Hz do 16 Hz CMC 2,2 %\n- charakterystyka częstotliwościowa 20 Hz do 400 Hz CMC 2,0 %\n- charakterystyka częstotliwościowa 500 Hz do 1600 Hz CMC 2,1 %\n- charakterystyka częstotliwościowa 2000 Hz CMC 2,2 %\n- charakterystyka częstotliwościowa 2500 Hz do 4000 Hz CMC 2,8 %\n- charakterystyka częstotliwościowa 5000 Hz do 6300 Hz CMC 3,0 %\n- charakterystyka częstotliwościowa 8000 Hz CMC 3,5 %\n- charakterystyka częstotliwościowa 10000 Hz CMC 4,0 %\nW stałej lokalizacji (S)","reference":"ISO 16063-21:2003","norm_bases":["ISO 16063-21:2003"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Przyspieszenie drgań mechanicznych","regulatory_area_en":"Acceleration of mechanical vibration","outside_premises":false,"location_of_activity":"S","note":"Pracownia Akustyki, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Acoustics Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Przetworniki drgań mechanicznych Wzorcowanie — Przyspieszenie drgań mechanicznych\nZakres:\n0,1 pC·m⁻¹·s² do 1000 pC·m⁻¹·s² CMC 1,8 %\n0,1 mV· m⁻¹·s² do 1000 mV· m⁻¹·s² CMC 1,8 %\n- charakterystyka częstotliwościowa 0,5 Hz do 16 Hz CMC 2,2 %\n- charakterystyka częstotliwościowa 20 Hz do 400 Hz CMC 2,0 %\n- charakterystyka częstotliwościowa 500 Hz do 1600 Hz CMC 2,1 %\n- charakterystyka częstotliwościowa 2000 Hz CMC 2,2 %\n- charakterystyka częstotliwościowa 2500 Hz do 4000 Hz CMC 2,8 %\n- charakterystyka częstotliwościowa 5000 Hz do 6300 Hz CMC 3,0 %\n- charakterystyka częstotliwościowa 8000 Hz CMC 3,5 %\n- charakterystyka częstotliwościowa 10000 Hz CMC 4,0 %\nW stałej lokalizacji (S) ISO 16063-21:2003 Przetworniki drgan mechanicznych Wzorcowanie — Przyspieszenie drgan mechanicznych\nZakres:\n0,1 pC·m⁻¹·s² do 1000 pC·m⁻¹·s² CMC 1,8 %\n0,1 mV· m⁻¹·s² do 1000 mV· m⁻¹·s² CMC 1,8 %\n- charakterystyka czestotliwosciowa 0,5 Hz do 16 Hz CMC 2,2 %\n- charakterystyka czestotliwosciowa 20 Hz do 400 Hz CMC 2,0 %\n- charakterystyka czestotliwosciowa 500 Hz do 1600 Hz CMC 2,1 %\n- charakterystyka czestotliwosciowa 2000 Hz CMC 2,2 %\n- charakterystyka czestotliwosciowa 2500 Hz do 4000 Hz CMC 2,8 %\n- charakterystyka czestotliwosciowa 5000 Hz do 6300 Hz CMC 3,0 %\n- charakterystyka czestotliwosciowa 8000 Hz CMC 3,5 %\n- charakterystyka czestotliwosciowa 10000 Hz CMC 4,0 %\nW stalej lokalizacji (S) ISO 16063-21:2003","search_en":"Vibration transducers Calibration — Acceleration of mechanical vibration At permanent location (S) Acceleration of mechanical vibration At permanent location (S) - frequency response - frequency response - frequency response - frequency response - frequency response - frequency response - frequency response - frequency response ISO 16063-21:2003","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Beschleunigung mechanischer Schwingungen","parameters_de":[{"name":"","range":"0,1 pC·m⁻¹·s² to 1000 pC·m⁻¹·s²","cmc":"1,8 %"},{"name":"","range":"0,1 mV· m⁻¹·s² to 1000 mV· m⁻¹·s²","cmc":"1,8 %"},{"name":"- Frequenzgang","range":"0,5 Hz to 16 Hz","cmc":"2,2 %"},{"name":"- Frequenzgang","range":"20 Hz bis 400 Hz","cmc":"2,0 %"},{"name":"- Frequenzgang","range":"500 Hz to 1600 Hz","cmc":"2,1 %"},{"name":"- Frequenzgang","range":"2000 Hz","cmc":"2,2 %"},{"name":"- Frequenzgang","range":"2500 Hz to 4000 Hz","cmc":"2,8 %"},{"name":"- Frequenzgang","range":"5000 Hz to 6300 Hz","cmc":"3,0 %"},{"name":"- Frequenzgang","range":"8000 Hz","cmc":"3,5 %"},{"name":"- Frequenzgang","range":"10000 Hz","cmc":"4,0 %"}],"regulatory_area_de":"Beschleunigung mechanischer Schwingungen","search_de":"Schwingungsaufnehmer Kalibrierung — Beschleunigung mechanischer Schwingungen Am festen Standort (S) Beschleunigung mechanischer Schwingungen Am festen Standort (S) - Frequenzgang - Frequenzgang - Frequenzgang - Frequenzgang - Frequenzgang - Frequenzgang - Frequenzgang - Frequenzgang ISO 16063-21:2003","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Schwingungsaufnehmer","methodology_zh":"校准 — 机械振动加速度","parameters_zh":[{"name":"","range":"0,1 pC·m⁻¹·s² to 1000 pC·m⁻¹·s²","cmc":"1,8 %"},{"name":"","range":"0,1 mV· m⁻¹·s² to 1000 mV· m⁻¹·s²","cmc":"1,8 %"},{"name":"- 频率响应","range":"0,5 Hz to 16 Hz","cmc":"2,2 %"},{"name":"- 频率响应","range":"20 Hz to 400 Hz","cmc":"2,0 %"},{"name":"- 频率响应","range":"500 Hz to 1600 Hz","cmc":"2,1 %"},{"name":"- 频率响应","range":"2000 Hz","cmc":"2,2 %"},{"name":"- 频率响应","range":"2500 Hz to 4000 Hz","cmc":"2,8 %"},{"name":"- 频率响应","range":"5000 Hz to 6300 Hz","cmc":"3,0 %"},{"name":"- 频率响应","range":"8000 Hz","cmc":"3,5 %"},{"name":"- 频率响应","range":"10000 Hz","cmc":"4,0 %"}],"regulatory_area_zh":"机械振动加速度","search_zh":"机械振动传感器 校准 — 机械振动加速度 在固定地点 (S) 机械振动加速度 在固定地点 (S) - 频率响应 - 频率响应 - 频率响应 - 频率响应 - 频率响应 - 频率响应 - 频率响应 - 频率响应 ISO 16063-21:2003","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"机械振动传感器","methodology_cs":"Kalibrace — Zrychlení mechanického kmitání","parameters_cs":[{"name":"","range":"0,1 pC·m⁻¹·s² to 1000 pC·m⁻¹·s²","cmc":"1,8 %"},{"name":"","range":"0,1 mV· m⁻¹·s² to 1000 mV· m⁻¹·s²","cmc":"1,8 %"},{"name":"- frekvenční charakteristika","range":"0,5 Hz to 16 Hz","cmc":"2,2 %"},{"name":"- frekvenční charakteristika","range":"20 Hz to 400 Hz","cmc":"2,0 %"},{"name":"- frekvenční charakteristika","range":"500 Hz to 1600 Hz","cmc":"2,1 %"},{"name":"- frekvenční charakteristika","range":"2000 Hz","cmc":"2,2 %"},{"name":"- frekvenční charakteristika","range":"2500 Hz to 4000 Hz","cmc":"2,8 %"},{"name":"- frekvenční charakteristika","range":"5000 Hz to 6300 Hz","cmc":"3,0 %"},{"name":"- frekvenční charakteristika","range":"8000 Hz","cmc":"3,5 %"},{"name":"- frekvenční charakteristika","range":"10000 Hz","cmc":"4,0 %"}],"regulatory_area_cs":"Zrychlení mechanického kmitání","search_cs":"Snímače mechanického kmitání Kalibrace — Zrychlení mechanického kmitání Ve stálé lokalitě (S) Zrychlení mechanického kmitání Ve stálé lokalitě (S) - frekvenční charakteristika - frekvenční charakteristika - frekvenční charakteristika - frekvenční charakteristika - frekvenční charakteristika - frekvenční charakteristika - frekvenční charakteristika - frekvenční charakteristika ISO 16063-21:2003","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Snímače mechanického kmitání"},{"_id":"60d71cabd7140ad8ae415ac1","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Kalibratory drgań mechanicznych","test_object_en":"Vibration calibrators","methodology":"Wzorcowanie — Przyspieszenie drgań mechanicznych","methodology_en":"Calibration — Acceleration of mechanical vibration","parameters":[{"name":"","range":"15 Hz do 2 kHz","cmc":"1,8 %"}],"parameters_en":[{"name":"","range":"15 Hz to 2 kHz","cmc":"1,8 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Przyspieszenie drgań mechanicznych\n15 Hz do 2 kHz CMC 1,8 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"P-02/11 w oparciu o PN-EN ISO 8041-1:2017","norm_bases":["P-02/11","PN-EN ISO 8041-1:2017"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Przyspieszenie drgań mechanicznych","regulatory_area_en":"Acceleration of mechanical vibration","outside_premises":false,"location_of_activity":"S","note":"Pracownia Akustyki, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Acoustics Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Kalibratory drgań mechanicznych Wzorcowanie — Przyspieszenie drgań mechanicznych\n15 Hz do 2 kHz CMC 1,8 %\nProcedura wewnętrzna; W stałej lokalizacji (S) P-02/11 w oparciu o PN-EN ISO 8041-1:2017 Kalibratory drgan mechanicznych Wzorcowanie — Przyspieszenie drgan mechanicznych\n15 Hz do 2 kHz CMC 1,8 %\nProcedura wewnetrzna; W stalej lokalizacji (S) P-02/11 w oparciu o PN-EN ISO 8041-1:2017","search_en":"Vibration calibrators Calibration — Acceleration of mechanical vibration Internal procedure; At permanent location (S) Acceleration of mechanical vibration Internal procedure At permanent location (S) P-02/11 based on PN-EN ISO 8041-1:2017","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"P-02/11 based on PN-EN ISO 8041-1:2017","methodology_de":"Kalibrierung — Beschleunigung mechanischer Schwingungen","parameters_de":[{"name":"","range":"15 Hz to 2 kHz","cmc":"1,8 %"}],"reference_de":"P-02/11 auf Grundlage von PN-EN ISO 8041-1:2017","regulatory_area_de":"Beschleunigung mechanischer Schwingungen","search_de":"Schwingungskalibratoren Kalibrierung — Beschleunigung mechanischer Schwingungen Internes Verfahren; Am festen Standort (S) Beschleunigung mechanischer Schwingungen Internes Verfahren Am festen Standort (S) P-02/11 auf Grundlage von PN-EN ISO 8041-1:2017","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Schwingungskalibratoren","methodology_zh":"校准 — 机械振动加速度","parameters_zh":[{"name":"","range":"15 Hz to 2 kHz","cmc":"1,8 %"}],"reference_zh":"P-02/11 依据PN-EN ISO 8041-1:2017","regulatory_area_zh":"机械振动加速度","search_zh":"振动校准器 校准 — 机械振动加速度 内部程序；在固定地点 (S) 机械振动加速度 内部程序 在固定地点 (S) P-02/11 依据PN-EN ISO 8041-1:2017","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"振动校准器","methodology_cs":"Kalibrace — Zrychlení mechanického kmitání","parameters_cs":[{"name":"","range":"15 Hz to 2 kHz","cmc":"1,8 %"}],"reference_cs":"P-02/11 na základě PN-EN ISO 8041-1:2017","regulatory_area_cs":"Zrychlení mechanického kmitání","search_cs":"Kalibrátory mechanického kmitání Kalibrace — Zrychlení mechanického kmitání Vnitřní postup; Ve stálé lokalitě (S) Zrychlení mechanického kmitání Vnitřní postup Ve stálé lokalitě (S) P-02/11 na základě PN-EN ISO 8041-1:2017","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory mechanického kmitání"},{"_id":"eeb8f2cfa10261579d5fa424","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Mierniki drgań maszyn (mierniki przyspieszenia)","test_object_en":"Machine vibration meters (accelerometers)","methodology":"Wzorcowanie — Przyspieszenie drgań mechanicznych","methodology_en":"Calibration — Acceleration of mechanical vibration","parameters":[{"name":"- odpowiedź miernika na sygnał odniesienia dla sygnału mechanicznego","range":"dla 80 Hz; 10 m·s⁻²","cmc":"2,0 %"},{"name":"- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego","range":"0,5 Hz do 16 Hz","cmc":"2,2 %"},{"name":"- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego","range":"20 Hz do 400 Hz","cmc":"2,0 %"},{"name":"- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego","range":"500 Hz do 1600 Hz","cmc":"2,1 %"},{"name":"- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego","range":"2000 Hz","cmc":"2,2 %"}],"parameters_en":[{"name":"- response of the meter to the reference signal for a mechanical signal","range":"for 80 Hz; 10 m·s⁻²","cmc":"2,0 %"},{"name":"- frequency responses of the meter for a mechanical signal","range":"0,5 Hz to 16 Hz","cmc":"2,2 %"},{"name":"- frequency responses of the meter for a mechanical signal","range":"20 Hz to 400 Hz","cmc":"2,0 %"},{"name":"- frequency responses of the meter for a mechanical signal","range":"500 Hz to 1600 Hz","cmc":"2,1 %"},{"name":"- frequency responses of the meter for a mechanical signal","range":"2000 Hz","cmc":"2,2 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Przyspieszenie drgań mechanicznych\nZakres:\n- odpowiedź miernika na sygnał odniesienia dla sygnału mechanicznego dla 80 Hz; 10 m·s⁻² CMC 2,0 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego 0,5 Hz do 16 Hz CMC 2,2 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego 20 Hz do 400 Hz CMC 2,0 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego 500 Hz do 1600 Hz CMC 2,1 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego 2000 Hz CMC 2,2 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"P-02/11 w oparciu o ISO 16063-21:2003","norm_bases":["P-02/11","ISO 16063-21:2003"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Przyspieszenie drgań mechanicznych","regulatory_area_en":"Acceleration of mechanical vibration","outside_premises":false,"location_of_activity":"S","note":"Pracownia Akustyki, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Acoustics Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Mierniki drgań maszyn (mierniki przyspieszenia) Wzorcowanie — Przyspieszenie drgań mechanicznych\nZakres:\n- odpowiedź miernika na sygnał odniesienia dla sygnału mechanicznego dla 80 Hz; 10 m·s⁻² CMC 2,0 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego 0,5 Hz do 16 Hz CMC 2,2 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego 20 Hz do 400 Hz CMC 2,0 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego 500 Hz do 1600 Hz CMC 2,1 %\n- charakterystyki częstotliwościowe miernika dla sygnału mechanicznego 2000 Hz CMC 2,2 %\nProcedura wewnętrzna; W stałej lokalizacji (S) P-02/11 w oparciu o ISO 16063-21:2003 Mierniki drgan maszyn (mierniki przyspieszenia) Wzorcowanie — Przyspieszenie drgan mechanicznych\nZakres:\n- odpowiedz miernika na sygnal odniesienia dla sygnalu mechanicznego dla 80 Hz; 10 m·s⁻² CMC 2,0 %\n- charakterystyki czestotliwosciowe miernika dla sygnalu mechanicznego 0,5 Hz do 16 Hz CMC 2,2 %\n- charakterystyki czestotliwosciowe miernika dla sygnalu mechanicznego 20 Hz do 400 Hz CMC 2,0 %\n- charakterystyki czestotliwosciowe miernika dla sygnalu mechanicznego 500 Hz do 1600 Hz CMC 2,1 %\n- charakterystyki czestotliwosciowe miernika dla sygnalu mechanicznego 2000 Hz CMC 2,2 %\nProcedura wewnetrzna; W stalej lokalizacji (S) P-02/11 w oparciu o ISO 16063-21:2003","search_en":"Machine vibration meters (accelerometers) Calibration — Acceleration of mechanical vibration Internal procedure; At permanent location (S) Acceleration of mechanical vibration Internal procedure At permanent location (S) - response of the meter to the reference signal for a mechanical signal - frequency responses of the meter for a mechanical signal - frequency responses of the meter for a mechanical signal - frequency responses of the meter for a mechanical signal - frequency responses of the meter for a mechanical signal P-02/11 based on ISO 16063-21:2003","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"P-02/11 based on ISO 16063-21:2003","methodology_de":"Kalibrierung — Beschleunigung mechanischer Schwingungen","parameters_de":[{"name":"- Reaktion des Messgeräts auf das Bezugssignal für ein mechanisches Signal","range":"for 80 Hz; 10 m·s⁻²","cmc":"2,0 %"},{"name":"- Frequenzgänge des Messgeräts für ein mechanisches Signal","range":"0,5 Hz to 16 Hz","cmc":"2,2 %"},{"name":"- Frequenzgänge des Messgeräts für ein mechanisches Signal","range":"20 Hz bis 400 Hz","cmc":"2,0 %"},{"name":"- Frequenzgänge des Messgeräts für ein mechanisches Signal","range":"500 Hz to 1600 Hz","cmc":"2,1 %"},{"name":"- Frequenzgänge des Messgeräts für ein mechanisches Signal","range":"2000 Hz","cmc":"2,2 %"}],"reference_de":"P-02/11 auf Grundlage von ISO 16063-21:2003","regulatory_area_de":"Beschleunigung mechanischer Schwingungen","search_de":"Maschinenschwingungsmesser (Beschleunigungsmesser) Kalibrierung — Beschleunigung mechanischer Schwingungen Internes Verfahren; Am festen Standort (S) Beschleunigung mechanischer Schwingungen Internes Verfahren Am festen Standort (S) - Reaktion des Messgeräts auf das Bezugssignal für ein mechanisches Signal - Frequenzgänge des Messgeräts für ein mechanisches Signal - Frequenzgänge des Messgeräts für ein mechanisches Signal - Frequenzgänge des Messgeräts für ein mechanisches Signal - Frequenzgänge des Messgeräts für ein mechanisches Signal P-02/11 auf Grundlage von ISO 16063-21:2003","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Maschinenschwingungsmesser (Beschleunigungsmesser)","methodology_zh":"校准 — 机械振动加速度","parameters_zh":[{"name":"- 仪器对机械参考信号的响应","range":"for 80 Hz; 10 m·s⁻²","cmc":"2,0 %"},{"name":"- 仪器对机械信号的频率响应","range":"0,5 Hz to 16 Hz","cmc":"2,2 %"},{"name":"- 仪器对机械信号的频率响应","range":"20 Hz to 400 Hz","cmc":"2,0 %"},{"name":"- 仪器对机械信号的频率响应","range":"500 Hz to 1600 Hz","cmc":"2,1 %"},{"name":"- 仪器对机械信号的频率响应","range":"2000 Hz","cmc":"2,2 %"}],"reference_zh":"P-02/11 依据ISO 16063-21:2003","regulatory_area_zh":"机械振动加速度","search_zh":"机器振动测量仪（加速度计） 校准 — 机械振动加速度 内部程序；在固定地点 (S) 机械振动加速度 内部程序 在固定地点 (S) - 仪器对机械参考信号的响应 - 仪器对机械信号的频率响应 - 仪器对机械信号的频率响应 - 仪器对机械信号的频率响应 - 仪器对机械信号的频率响应 P-02/11 依据ISO 16063-21:2003","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"机器振动测量仪（加速度计）","methodology_cs":"Kalibrace — Zrychlení mechanického kmitání","parameters_cs":[{"name":"- odezva měřiče na referenční signál pro mechanický signál","range":"for 80 Hz; 10 m·s⁻²","cmc":"2,0 %"},{"name":"- frekvenční charakteristiky měřiče pro mechanický signál","range":"0,5 Hz to 16 Hz","cmc":"2,2 %"},{"name":"- frekvenční charakteristiky měřiče pro mechanický signál","range":"20 Hz to 400 Hz","cmc":"2,0 %"},{"name":"- frekvenční charakteristiky měřiče pro mechanický signál","range":"500 Hz to 1600 Hz","cmc":"2,1 %"},{"name":"- frekvenční charakteristiky měřiče pro mechanický signál","range":"2000 Hz","cmc":"2,2 %"}],"reference_cs":"P-02/11 na základě ISO 16063-21:2003","regulatory_area_cs":"Zrychlení mechanického kmitání","search_cs":"Měřiče vibrací strojů (měřiče zrychlení) Kalibrace — Zrychlení mechanického kmitání Vnitřní postup; Ve stálé lokalitě (S) Zrychlení mechanického kmitání Vnitřní postup Ve stálé lokalitě (S) - odezva měřiče na referenční signál pro mechanický signál - frekvenční charakteristiky měřiče pro mechanický signál - frekvenční charakteristiky měřiče pro mechanický signál - frekvenční charakteristiky měřiče pro mechanický signál - frekvenční charakteristiky měřiče pro mechanický signál P-02/11 na základě ISO 16063-21:2003","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče vibrací strojů (měřiče zrychlení)"},{"_id":"d9a1bb6feef5c73c34ce716b","lab_id":"6afa3b8b8989a133b76445ab","country":"PL","accr_number":"AP 027","accr_body":"PCA","test_object":"Analizatory spalin samochodowych","test_object_en":"Automotive exhaust gas analysers","methodology":"Wzorcowanie — Ułamek molowy (analiza gazów)","methodology_en":"Calibration — Mole fraction (gas analysis)","parameters":[{"name":"CO","range":"4 mmol/mol do 6 mmol/mol","cmc":"3%"},{"name":"CO","range":"14 mmol/mol do 16 mmol/mol","cmc":"2%"},{"name":"CO","range":"29 mmol/mol do 45 mmol/mol","cmc":"2%"},{"name":"CO₂","range":"48 mmol/mol do 71 mmol/mol","cmc":"2%"},{"name":"CO₂","range":"88 mmol/mol do 166 mmol/mol","cmc":"2%"},{"name":"C₃H₈","range":"160 mmol/mol do 240 mmol/mol","cmc":"4%"},{"name":"C₃H₈","range":"540 mmol/mol do 640 mmol/mol","cmc":"3%"},{"name":"C₃H₈","range":"1600 mmol/mol do 2400 mmol/mol","cmc":"2%"}],"parameters_en":[{"name":"CO","range":"4 mmol/mol to 6 mmol/mol","cmc":"3%"},{"name":"CO","range":"14 mmol/mol to 16 mmol/mol","cmc":"2%"},{"name":"CO","range":"29 mmol/mol to 45 mmol/mol","cmc":"2%"},{"name":"CO₂","range":"48 mmol/mol to 71 mmol/mol","cmc":"2%"},{"name":"CO₂","range":"88 mmol/mol to 166 mmol/mol","cmc":"2%"},{"name":"C₃H₈","range":"160 mmol/mol to 240 mmol/mol","cmc":"4%"},{"name":"C₃H₈","range":"540 mmol/mol to 640 mmol/mol","cmc":"3%"},{"name":"C₃H₈","range":"1600 mmol/mol to 2400 mmol/mol","cmc":"2%"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ułamek molowy (analiza gazów)\nZakres:\nCO 4 mmol/mol do 6 mmol/mol CMC 3%\nCO 14 mmol/mol do 16 mmol/mol CMC 2%\nCO 29 mmol/mol do 45 mmol/mol CMC 2%\nCO₂ 48 mmol/mol do 71 mmol/mol CMC 2%\nCO₂ 88 mmol/mol do 166 mmol/mol CMC 2%\nC₃H₈ 160 mmol/mol do 240 mmol/mol CMC 4%\nC₃H₈ 540 mmol/mol do 640 mmol/mol CMC 3%\nC₃H₈ 1600 mmol/mol do 2400 mmol/mol CMC 2%\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"P-02/01","norm_bases":["P-02/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ułamek molowy (analiza gazów)","regulatory_area_en":"Mole fraction (gas analysis)","outside_premises":false,"location_of_activity":"S","note":"Pracownia Analizatorów Spalin, ul. Kórnicka 27, 62-020 Swarzędz","note_en":"Exhaust Gas Analyser Workshop, ul. Kórnicka 27, 62-020 Swarzędz","search_text":"Analizatory spalin samochodowych Wzorcowanie — Ułamek molowy (analiza gazów)\nZakres:\nCO 4 mmol/mol do 6 mmol/mol CMC 3%\nCO 14 mmol/mol do 16 mmol/mol CMC 2%\nCO 29 mmol/mol do 45 mmol/mol CMC 2%\nCO₂ 48 mmol/mol do 71 mmol/mol CMC 2%\nCO₂ 88 mmol/mol do 166 mmol/mol CMC 2%\nC₃H₈ 160 mmol/mol do 240 mmol/mol CMC 4%\nC₃H₈ 540 mmol/mol do 640 mmol/mol CMC 3%\nC₃H₈ 1600 mmol/mol do 2400 mmol/mol CMC 2%\nProcedura wewnętrzna; W stałej lokalizacji (S) P-02/01 Analizatory spalin samochodowych Wzorcowanie — Ulamek molowy (analiza gazow)\nZakres:\nCO 4 mmol/mol do 6 mmol/mol CMC 3%\nCO 14 mmol/mol do 16 mmol/mol CMC 2%\nCO 29 mmol/mol do 45 mmol/mol CMC 2%\nCO₂ 48 mmol/mol do 71 mmol/mol CMC 2%\nCO₂ 88 mmol/mol do 166 mmol/mol CMC 2%\nC₃H₈ 160 mmol/mol do 240 mmol/mol CMC 4%\nC₃H₈ 540 mmol/mol do 640 mmol/mol CMC 3%\nC₃H₈ 1600 mmol/mol do 2400 mmol/mol CMC 2%\nProcedura wewnetrzna; W stalej lokalizacji (S) P-02/01","search_en":"Automotive exhaust gas analysers Calibration — Mole fraction (gas analysis) Internal procedure; At permanent location (S) Mole fraction (gas analysis) Internal procedure At permanent location (S) CO CO CO CO₂ CO₂ C₃H₈ C₃H₈ C₃H₈ P-02/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Stoffmengenanteil (Gasanalyse)","parameters_de":[{"name":"CO","range":"4 mmol/mol bis 6 mmol/mol","cmc":"3%"},{"name":"CO","range":"14 mmol/mol to 16 mmol/mol","cmc":"2%"},{"name":"CO","range":"29 mmol/mol to 45 mmol/mol","cmc":"2%"},{"name":"CO₂","range":"48 mmol/mol bis 71 mmol/mol","cmc":"2%"},{"name":"CO₂","range":"88 mmol/mol to 166 mmol/mol","cmc":"2%"},{"name":"C₃H₈","range":"160 mmol/mol to 240 mmol/mol","cmc":"4%"},{"name":"C₃H₈","range":"540 mmol/mol to 640 mmol/mol","cmc":"3%"},{"name":"C₃H₈","range":"1600 mmol/mol to 2400 mmol/mol","cmc":"2%"}],"regulatory_area_de":"Stoffmengenanteil (Gasanalyse)","search_de":"Abgasanalysatoren für Kraftfahrzeuge Kalibrierung — Stoffmengenanteil (Gasanalyse) Internes Verfahren; Am festen Standort (S) Stoffmengenanteil (Gasanalyse) Internes Verfahren Am festen Standort (S) CO CO CO CO₂ CO₂ C₃H₈ C₃H₈ C₃H₈ P-02/01","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Abgasanalysatoren für Kraftfahrzeuge","methodology_zh":"校准 — 摩尔分数（气体分析）","parameters_zh":[{"name":"CO","range":"4 mmol/mol 至 6 mmol/mol","cmc":"3%"},{"name":"CO","range":"14 mmol/mol to 16 mmol/mol","cmc":"2%"},{"name":"CO","range":"29 mmol/mol to 45 mmol/mol","cmc":"2%"},{"name":"CO₂","range":"48 mmol/mol 至 71 mmol/mol","cmc":"2%"},{"name":"CO₂","range":"88 mmol/mol to 166 mmol/mol","cmc":"2%"},{"name":"C₃H₈","range":"160 mmol/mol to 240 mmol/mol","cmc":"4%"},{"name":"C₃H₈","range":"540 mmol/mol to 640 mmol/mol","cmc":"3%"},{"name":"C₃H₈","range":"1600 mmol/mol to 2400 mmol/mol","cmc":"2%"}],"regulatory_area_zh":"摩尔分数（气体分析）","search_zh":"汽车尾气分析仪 校准 — 摩尔分数（气体分析） 内部程序；在固定地点 (S) 摩尔分数（气体分析） 内部程序 在固定地点 (S) CO CO CO CO₂ CO₂ C₃H₈ C₃H₈ C₃H₈ P-02/01","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"汽车尾气分析仪","methodology_cs":"Kalibrace — Látkový zlomek (analýza plynů)","parameters_cs":[{"name":"CO","range":"4 mmol/mol do 6 mmol/mol","cmc":"3%"},{"name":"CO","range":"14 mmol/mol to 16 mmol/mol","cmc":"2%"},{"name":"CO","range":"29 mmol/mol to 45 mmol/mol","cmc":"2%"},{"name":"CO₂","range":"48 mmol/mol do 71 mmol/mol","cmc":"2%"},{"name":"CO₂","range":"88 mmol/mol to 166 mmol/mol","cmc":"2%"},{"name":"C₃H₈","range":"160 mmol/mol to 240 mmol/mol","cmc":"4%"},{"name":"C₃H₈","range":"540 mmol/mol to 640 mmol/mol","cmc":"3%"},{"name":"C₃H₈","range":"1600 mmol/mol to 2400 mmol/mol","cmc":"2%"}],"regulatory_area_cs":"Látkový zlomek (analýza plynů)","search_cs":"Analyzátory výfukových plynů automobilů Kalibrace — Látkový zlomek (analýza plynů) Vnitřní postup; Ve stálé lokalitě (S) Látkový zlomek (analýza plynů) Vnitřní postup Ve stálé lokalitě (S) CO CO CO CO₂ CO₂ C₃H₈ C₃H₈ C₃H₈ P-02/01","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Analyzátory výfukových plynů automobilů"}],"has_pdf":true}