🇵🇱 Instytut Kolejnictwa PL

PCA AP 024 • Warszawa, Poland • 43 calibration items

Metrology & calibration

Instytut Kolejnictwa is a calibration laboratory accredited by PCA under number AP 024 (Warszawa, Poland). Its accreditation scope covers 43 calibration items in the following areas: Metrology & calibration. Calibrated items include: Multimeters, Calibrators, Power supplies, Analogue and digital ammeters. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Direct method; At permanent location (S), Internal procedure; Indirect method; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 024
  • Calibration items in scope: 43
  • Types of calibrated items: 41
  • Calibration principles used: 10
  • City: Warszawa, Poland
  • Valid until: 19-12-2028
Accreditation number
AP 024
Accreditation body
PCA
Address
ul. Chłopickiego 50, 04-257 Warszawa
City
Warszawa, Poland
Division
Metrology Laboratory
Valid until
19-12-2028

What this laboratory calibrates (41)

Calibration principles (10)

Certificate information

Issue date
24.11.2025
Issue no.
22
Certificate date
16.09.2019
Accreditation cycle
03.12.2024 — 19.12.2028
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (43)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Analogue dial gauges with a scale interval of 0,01 mm Calibration — Length
0 mm to 10,0 mm · CMC 2,6 µm 0 mm to 25,0 mm · CMC 3,7 µm
Length
Internal procedure; Indirect method; At permanent location (S) Internal procedure PP-LMM-15
2 Analogue dial gauges with a scale interval of 0,001 mm Calibration — Length
0 mm to 1,0 mm · CMC 2,0 µm 0 mm to 5,0 mm · CMC 3,5 µm
Length
Internal procedure; Indirect method; At permanent location (S) Internal procedure PP-LMM-15
3 Lever-type analogue dial gauges Calibration — Length
-1 mm to 1 mm · CMC 2,6 µm
Length
Internal procedure; Indirect method; At permanent location (S) Internal procedure PP-LMM-15
4 Digital dial gauges with a resolution of 0,01 mm Calibration — Length
0 mm to 12,7 mm · CMC 8,8 µm 0 mm to 25,4 mm · CMC 8,8 µm
Length
Internal procedure; Indirect method; At permanent location (S) Internal procedure PP-LMM-15
5 Digital dial gauges with a resolution of 0,001 mm Calibration — Length
0 mm to 12,7 mm · CMC 2,1 µm 0 mm to 25,4 mm · CMC 3,4 µm
Length
Internal procedure; Indirect method; At permanent location (S) Internal procedure PP-LMM-15
6 Micrometer depth gauges Calibration — Length
0 mm to 50 mm · CMC 2,1 µm 50 mm do 100 mm · CMC 3,2 µm
Length
Internal procedure; Direct method; At permanent location (S) Internal procedure PP-LMM-10
7 Vernier depth gauges Calibration — Length
0 mm to 200 mm · CMC 0,01 mm 0 mm to 600 mm · CMC 0,02 mm
Length
Internal procedure; Direct method; At permanent location (S) Internal procedure PP-LMM-08
8 External micrometers Calibration — Length
0 mm to 50 mm · CMC 2,1 µm 50 mm do 100 mm · CMC 3,2 µm 100 mm do 150 mm · CMC 4,4 µm 150 mm do 200 mm · CMC 5,7 µm 200 mm do 250 mm · CMC 7,0 µm 250 mm do 300 mm · CMC 8,3 µm 300 mm do 350 mm · CMC 9,7 µm 350 mm do 400 mm · CMC 11 µm 400 mm do 450 mm · CMC 12 µm 450 mm do 500 mm · CMC 14 µm
Length
Internal procedure; Direct method; At permanent location (S) Internal procedure PP-LMM-09
9 Indicating micrometers Calibration — Length
25 mm to 50 mm · CMC 1,6 µm 50 mm do 100 mm · CMC 2,9 µm
Length
Internal procedure; Direct method; At permanent location (S) Internal procedure PP-LMM-13
10 Gauge blocks (classes 0, 1, 2) Calibration — Length
- steel — 0,5 mm to 100 mm · CMC Q[0,07; 1,08∙L] µm - ceramic — 0,5 mm to 100 mm · CMC Q[0,08; 1,44∙L] µm
Length
Internal procedure; Comparison method using gauge blocks and a two-probe comparator; At permanent location (S) Internal procedure PP-LMM-01 based on PN-EN ISO 3650:2000
11 Gauge blocks (classes 0, 1, 2) Calibration — Length
- steel — 125 mm to 500 mm · CMC Q[0,17; 1,10∙L] µm - ceramic — 125 mm to 500 mm · CMC Q[0,16; 1,44∙L] µm
Length
Internal procedure; Comparison method using gauge blocks and an optimeter; At permanent location (S) Internal procedure PP-LMM-02 based on PN-EN ISO 3650:2000
12 Special gauges Calibration — Length
0 mm to 200 mm · CMC 0,03 mm 0 mm do 500 mm · CMC 0,04 mm 0 mm to 1000 mm · CMC 0,05 mm
Length
Internal procedure; Measurement (external and internal dimensions). Direct method; At permanent location (S) Internal procedure PP-LMM-30
13 Instruments for measuring the distance between inner faces of wheelset wheels Calibration — Length
1330 mm to 1465 mm · CMC 0,20 mm
Length
Internal procedure; Direct method; At permanent location (S) Internal procedure PP-LMM-19
14 Instruments for measuring the running circle diameter of wheelset wheels Calibration — Length
800 mm to 1050 mm · CMC 0,04 mm
Length
Internal procedure; Direct method; At permanent location (S) Internal procedure PP-LMM-18
15 Instruments for measuring the buffer axis height above the rail head Calibration — Length
900 mm to 1150 mm · CMC 0,40 mm
Length
Internal procedure; Comparison method; At permanent location (S) Internal procedure PP-LMM-20
16 Vernier calipers Calibration — Length
0 mm to 200 mm · CMC 0,01 mm 0 mm do 625 mm · CMC 0,02 mm 0 mm to 1000 mm · CMC 0,03 mm
Length
Internal procedure; Direct method; At permanent location (S) Internal procedure PP-LMM-06
17 Special vernier instruments Calibration — Length
- flange height Ow — 0 mm to 45 mm · CMC 0,07 mm - flange width Og — 0 mm to 45 mm · CMC 0,07 mm - flange steepness qR — 0 mm to 25 mm · CMC 0,13 mm
Length
Internal procedure; Direct method; At permanent location (S) Internal procedure PP-LMM-17
18 Feeler gauges Calibration — Length
0,03 mm to 2 mm · CMC 0,6 µm
Length
Internal procedure; Comparison method; At permanent location (S) Internal procedure PP-LMM-14
19 Track gauges Calibration — Length
- track gauge — 1415 mm to 1470 mm · CMC 0,20 mm - track cant — -140 mm to 140 mm · CMC 0,50 mm
Length
Internal procedure; Comparison method; At permanent location (S) Internal procedure PP-LMM-23
20 Indicating snap gauges Calibration — Length
25 mm to 50 mm · CMC 1,6 µm 50 mm do 100 mm · CMC 2,9 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure PP-LMM-12
21 Vernier height gauges Calibration — Length
0 mm to 200 mm · CMC 0,01 mm 0 mm to 600 mm · CMC 0,02 mm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure PP-LMM-07
22 Setting standards for external dimensions Calibration — Length
0 mm to 100 mm · CMC 2,6 µm 100 mm to 250 mm · CMC 2,7 µm 250 mm to 500 mm · CMC 4,2 µm 500 mm to 650 mm · CMC 5,2 µm 650 mm to 800 mm · CMC 6,1 µm 800 mm to 1000 mm · CMC 7,5 µm 1000 mm to 1350 mm · CMC 9,8 µm 1350 mm to 1550 mm · CMC 11,1 µm 1550 mm to 1750 mm · CMC 12,5 µm 1750 mm to 2000 mm · CMC 14,2 µm 2000 mm to 2500 mm · CMC 17,5 µm 2500 mm to 3000 mm · CMC 20,9 µm
Length
Internal procedure; Direct method using a length measuring machine; At permanent location (S) Internal procedure PP-LMM-03
23 Optical flats Calibration — Length (surface geometry)
diameter — 0 mm to 100 mm · CMC 0,04 µm
Length (surface geometry)
Internal procedure; Indirect method using optical flats; At permanent location (S) Internal procedure PP-LMM-05
24 Calibrators
Power supplies
Calibration — DC voltage
100 µV to 100 mV · CMC 0,0011 % + 1 µV 100 mV to 1 V · CMC 0,0015 % + 2,5 µV 1 V to 10 V · CMC 0,0015 % + 15 µV 10 V to 100 V · CMC 0,004 % + 0,6 mV 100 V to 1000 V · CMC 0,004 % + 6 mV
DC voltage
Internal procedure; At permanent location (S) Internal procedure PP-LME-04
25 Multimeters
Analogue and digital voltmeters
Voltage probes
Calibration — DC voltage
0 µV · CMC 0,5 µV 100 µV to 220 mV · CMC 0,0009 % + 0,5 µV 220 mV to 2,2 V · CMC 0,0008 % 2,2 V to 22 V · CMC 0,0005 % 22 V to 220 V · CMC 0,0007 % 220 V to 1100 V · CMC 0,0008 %
DC voltage
Internal procedure; At permanent location (S) Internal procedures PP-LME-03 PP-LME-04
26 Calibrators
Power supplies
Calibration — DC current
1 µA to 10 µA · CMC 0,005 % + 0,4 nA 10 µA to 100 µA · CMC 0,006 % + 1,2 nA 100 µA to 1 mA · CMC 0,006 % + 0,012 µA 1 mA to 10 mA · CMC 0,006 % + 0,12 µA 10 mA to 100 mA · CMC 0,013 % + 3,8 µA 100 mA to 1 A · CMC 0,04 % + 0,064 mA 1 A to 3 A · CMC 0,04 % + 0,21 mA 3 A to 10 A · CMC 0,13 % + 4,5 mA
DC current
Internal procedure; At permanent location (S) Internal procedure PP-LME-04
27 Clamp meters Calibration — DC current
0 µA · CMC 6,9 nA 1 µA to 220 µA · CMC 0,004 % + 6 nA 220 µA to 2,2 mA · CMC 0,002 % + 0,06 µA 2,2 mA to 22 mA · CMC 0,0034 % + 0,05 µA 22 mA to 220 mA · CMC 0,0047 % + 0,7 µA 220 mA to 2,2 A · CMC 0,008 % + 0,012 mA 2,2 A to 20 A · CMC 0,012% + 0,002 A 20 A to 100 A · CMC 0,7 % + 0,14 A 100 A to 2500 A · CMC 0,7 % + 0,84 A
DC current
Internal procedure; At permanent location (S) Internal procedure PP-LME-04
28 Multimeters
Analogue and digital ammeters
Calibration — DC current
0 µA · CMC 6,9 nA 1 µA to 220 µA · CMC 0,004 % + 6 nA 220 µA to 2,2 mA · CMC 0,002 % + 0,06 µA 2,2 mA to 22 mA · CMC 0,0034 % + 0,05 µA 22 mA to 220 mA · CMC 0,0047 % + 0,7 µA 220 mA to 2,2 A · CMC 0,008 % + 0,012 mA 2,2 A to 20 A · CMC 0,012% + 0,002 A 20 A to 100 A · CMC 0,012% + 0,01 A
DC current
Internal procedure; At permanent location (S) Internal procedures PP-LME-03 PP-LME-04
29 Calibrators
Power supplies
Calibration — AC voltage
10 Hz to 20 kHz — 1 mV to 100 mV · CMC 0,034 % + 0,035 mV 10 Hz to 20 kHz — 100 mV to 1 V · CMC 0,031 % + 0,38 mV 10 Hz to 20 kHz — 1 V to 10 V · CMC 0,031 % + 3,8 mV 10 Hz to 20 kHz — 10 V to 100 V · CMC 0,031 % + 0,038 V 10 Hz to 20 kHz — 100 V to 700 V · CMC 0,029 % + 0,28 V 20 kHz to 50 kHz — 1 mV to 100 mV · CMC 0,1 % + 0,058 mV 20 kHz to 50 kHz — 100 mV to 1 V · CMC 0,098 % + 0,64 mV 20 kHz to 50 kHz — 1 V to 10 V · CMC 0,098 % + 6,4 mV 20 kHz to 50 kHz — 10 V to 100 V · CMC 0,098 % + 0,064 V 20 kHz to 50 kHz — 100 V to 700 V · CMC 0,094 % + 0,47 V 50 kHz to 100 kHz — 1 mV to 100 mV · CMC 0,6 % + 0,093 mV 50 kHz to 100 kHz — 100 mV to 1 V · CMC 0,6 % + 1 mV 50 kHz to 100 kHz — 1 V to 10 V · CMC 0,6 % + 0,01 V 50 kHz to 100 kHz — 10 V to 100 V · CMC 0,6 % + 0,10 V 50 kHz to 100 kHz — 100 V to 700 V · CMC 0,6 % + 0,75 V
AC voltage
Internal procedure; At permanent location (S) Internal procedure PP-LME-04
30 Analogue and digital voltmeters
Multimeters
Voltage probes
Calibration — AC voltage
40 Hz to 20 kHz — 1 mV to 2,2 mV · CMC 0,0083 % + 4 µV 40 Hz to 20 kHz — 2,2 mV to 22 mV · CMC 0,005 % + 8 µV 40 Hz to 20 kHz — 22 mV to 220 mV · CMC 0,005 % + 7 µV 40 Hz to 20 kHz — 220 mV to 2,2 V · CMC 0,004 % + 0,011 mV 40 Hz to 20 kHz — 2,2 V to 22 V · CMC 0,0042 % + 0,05 mV 40 Hz to 20 kHz — 22 V to 220 V · CMC 0,0052 % + 0,6 mV 20 kHz to 50 kHz — 1 mV to 22 mV · CMC 0,02 % + 4 µV 20 kHz to 50 kHz — 22 mV to 220 mV · CMC 0,012 % + 7 µV 20 kHz to 50 kHz — 220 mV to 2,2 V · CMC 0,0061 % + 0,02 mV 20 kHz to 50 kHz — 2,2 V to 22 V · CMC 0,007 % + 0,02 mV 20 kHz to 50 kHz — 22 V to 220 V · CMC 0,008 % + 1 mV 50 kHz to 100 kHz — 1 mV to 22 mV · CMC 0,05 % + 5 µV 50 kHz to 100 kHz — 22 mV to 220 mV · CMC 0,031 % + 17 µV 50 kHz to 100 kHz — 220 mV to 2,2 V · CMC 0,0081 % + 0,032 mV 50 kHz to 100 kHz — 2,2 V to 22 V · CMC 0,0083 % + 0,2 mV 50 kHz to 100 kHz — 22 V to 220 V · CMC 0,015 % + 2,6 mV 100 kHz to 300 kHz — 1 mV to 22 mV · CMC 0,11 % + 0,01 mV 100 kHz to 300 kHz — 22 mV to 220 mV · CMC 0,065 % + 0,02 mV 100 kHz to 300 kHz — 220 mV to 2,2 V · CMC 0,033 % + 0,08 mV 100 kHz to 300 kHz — 2,2 V to 22 V · CMC 0,025 % + 0,6 mV 100 kHz to 300 kHz — 22 V to 220 V · CMC 0,09 % + 16 mV 40 Hz to 50 Hz — 220 V to 1100 V · CMC 0,03 % + 0,016 V 50 Hz to 1 kHz — 220 V to 1100 V · CMC 0,007 % + 0,004 V 1 kHz to 20 kHz — 220 V to 1100 V · CMC 0,024 % + 0,46 V 20 kHz to 50 kHz — 220 V to 1100 V · CMC 0,053 % + 0,78 V 50 kHz to 100 kHz — 220 V to 1100 V · CMC 0,036 % + 1,8 V
AC voltage
Internal procedure; At permanent location (S) Internal procedures PP-LME-03 PP-LME-04
31 Calibrators Calibration — AC current
10 Hz to 2 kHz — 100 µA to 1 mA · CMC 0,053 % + 0,4 µA 10 Hz to 2 kHz — 1 mA to 10 mA · CMC 0,054 % + 4 µA 10 Hz to 2 kHz — 10 mA to 100 mA · CMC 0,054 % 0,04 mA 10 Hz to 2 kHz — 100 mA to 1 A · CMC 0,18 % 0,51 mA 10 Hz to 2 kHz — 1 A to 3 A · CMC 0,14 % + 2,6 mA 10 Hz to 2 kHz — 3 A to 10 A · CMC 0,38 % + 8,3 mA 2 kHz to 5 kHz — 100 µA to 1 mA · CMC 0,066 % + 0,4 µA 2 kHz to 5 kHz — 1 mA to 10 mA · CMC 0,066 % + 4 µA 2 kHz to 5 kHz — 10 mA to 100 mA · CMC 0,066 % + 0,04 mA 2 kHz to 5 kHz — 100 mA to 1 A · CMC 0,96 % + 0,51 mA 2 kHz to 5 kHz — 1 A to 3 A · CMC 0,93 % + 2,6 mA 2 kHz to 5 kHz — 3 A to 10 A · CMC 0,93 % + 8,2 mA 5 kHz to 10 kHz — 100 µA to 1 mA · CMC 0,066 % + 0,4 µA 5 kHz to 10 kHz — 1 mA to 10 mA · CMC 0,066 % + 4 µA 5 kHz to 10 kHz — 10 mA to 100 mA · CMC 0,0045 % + 8 µA 5 kHz to 10 kHz — 100 mA to 1 A · CMC 0,0045 % + 0,08 mA 5 kHz to 10 kHz — 1 A to 3 A · CMC 2,3 % + 2,1 mA 5 kHz to 10 kHz — 3 A to 10 A · CMC 2,3 % + 8,2 mA
AC current
Internal procedure; At permanent location (S) Internal procedure PP-LME-04
32 Clamp meters Calibration — AC current
40 Hz to 1 kHz — 1 µA to 220 µA · CMC 0,01 % + 0,008 µA 40 Hz to 1 kHz — 220 µA to 2,2 mA · CMC 0,0091 % + 0,06 µA 40 Hz to 1 kHz — 2,2 mA to 22 mA · CMC 0,01 % + 0,35 µA 40 Hz to 1 kHz — 22 mA to 220 mA · CMC 0,01 % + 2,4 µA 40 Hz to 1 kHz — 220 mA to 2,2 A · CMC 0,024 % + 0,04 mA 1 kHz to 5 kHz — 1 µA to 220 µA · CMC 0,028 % + 0,012 µA 1 kHz to 5 kHz — 220 µA to 2,2 mA · CMC 0,02 % + 0,12 µA 1 kHz to 5 kHz — 2,2 mA to 22 mA · CMC 0,02 % + 0,55 µA 1 kHz to 5 kHz — 22 mA to 220 mA · CMC 0,02 % + 3,6 µA 1 kHz to 5 kHz — 220 mA to 2,2 A · CMC 0,045 % + 0,08 mA 10 Hz to 850 Hz — 2,2 A to 20 A · CMC 0,009 % + 0,5 mA 10 Hz to 850 Hz — 20 A to 120 A · CMC 0,009 % + 2,4 mA 850 Hz to 5 kHz — 2,2 A to 20 A · CMC 0,04 % + 0,84 mA 850 Hz to 5 kHz — 20 A to 120 A · CMC 0,04 % + 4,8 mA 10 Hz to 300 Hz — 120 A to 500 A · CMC 0,7 % + 0,14 A 10 Hz to 300 Hz — 500 A to 3000 A · CMC 0,7 % + 0,84 A 300 Hz to 1 kHz — 120 A to 500 A · CMC 0,7 % + 0,14 A 300 Hz to 1 kHz — 500 A to 1000 A · CMC 0,7 % + 0,84 A 1 kHz to 3 kHz — 120 A to 300 A · CMC 0,8 % + 0,2 A
AC current
Internal procedure; At permanent location (S) Internal procedure PP-LME-04
33 Analogue and digital ammeters
Multimeters
Calibration — AC current
40 Hz to 1 kHz — 1 µA to 220 µA · CMC 0,01 % + 0,008 µA 40 Hz to 1 kHz — 220 µA to 2,2 mA · CMC 0,0091 % + 0,06 µA 40 Hz to 1 kHz — 2,2 mA to 22 mA · CMC 0,01 % + 0,35 µA 40 Hz to 1 kHz — 22 mA to 220 mA · CMC 0,01 % + 2,4 µA 40 Hz to 1 kHz — 220 mA to 2,2 A · CMC 0,024 % + 0,04 mA 1 kHz to 5 kHz — 1 µA to 220 µA · CMC 0,028 % + 0,012 µA 1 kHz to 5 kHz — 220 µA to 2,2 mA · CMC 0,02 % + 0,12 µA 1 kHz to 5 kHz — 2,2 mA to 22 mA · CMC 0,02 % + 0,55 µA 1 kHz to 5 kHz — 22 mA to 220 mA · CMC 0,02 % + 3,6 µA 1 kHz to 5 kHz — 220 mA to 2,2 A · CMC 0,045 % + 0,08 mA 10 Hz to 850 Hz — 2,2 A to 20 A · CMC 0,009 % + 0,5 mA 10 Hz to 850 Hz — 20 A to 120 A · CMC 0,009 % + 2,4 mA 850 Hz to 5 kHz — 2,2 A to 20 A · CMC 0,04 % + 0,84 mA 850 Hz to 5 kHz — 20 A to 120 A · CMC 0,04 % + 4,8 mA
AC current
Internal procedure; At permanent location (S) Internal procedures PP-LME-03 PP-LME-04
34 Shunts
Fixed and variable resistors
Calibration — DC resistance
1 µΩ to 100 µΩ · CMC 0,2 µΩ 100 µΩ to 1 mΩ · CMC 0,2 % 1 mΩ to 10 mΩ · CMC 0,037 % 10 mΩ to 100 mΩ · CMC 0,028 % 100 mΩ to 1 Ω · CMC 0,065 % 1 Ω to 10 Ω · CMC 0,0035 % + 0,06 mΩ 10 Ω to 100 Ω · CMC 0,0031 % + 0,46 mΩ 100 Ω to 1 kΩ · CMC 0,0024 % + 3,8 mΩ 1 kΩ to 10 kΩ · CMC 0,0031 % + 0,038 Ω 10 kΩ to 100 kΩ · CMC 0,0031 % + 0,39 Ω 100 kΩ to 1 MΩ · CMC 0,003 % + 5,1 Ω 1 MΩ to 10 MΩ · CMC 0,022 % + 0,13 kΩ 10 MΩ to 100 MΩ · CMC 0,024 % 100 MΩ to 1 GΩ · CMC 0,06 % 1 GΩ to 10 GΩ · CMC 0,45 %
DC resistance
Internal procedure; At permanent location (S) Internal procedure PP-LME-01
35 Calibrators Calibration — DC resistance
0,01 Ω to 1 Ω · CMC 0,0035 % + 0,06 mΩ 1 Ω to 10 Ω · CMC 0,0035 % + 0,06 mΩ 10 Ω to 100 Ω · CMC 0,0031 % + 0,46 mΩ 100 Ω to 1 kΩ · CMC 0,0024 % + 3,8 mΩ 1 kΩ to 10 kΩ · CMC 0,0031 % + 0,038 Ω 10 kΩ to 100 kΩ · CMC 0,0031 % + 0,39 Ω 100 kΩ to 1 MΩ · CMC 0,003 % + 5,1 Ω 1 MΩ to 10 MΩ · CMC 0,022 % + 0,13 kΩ 10 MΩ to 100 MΩ · CMC 0,23 % + 3,9 kΩ 100 MΩ to 1 GΩ · CMC 1,03 % + 0,13 MΩ
DC resistance
Internal procedure; At permanent location (S) Internal procedure PP-LME-04
36 Analogue and digital ohmmeters
Multimeters
Calibration — DC resistance
1 µΩ to 100 µΩ · CMC 0,2 µΩ 100 µΩ to 1 mΩ · CMC 0,2 % 1 mΩ to 10 mΩ · CMC 0,037 % 10 mΩ to 100 mΩ · CMC 0,028 % 100 mΩ to 1 Ω · CMC 0,065 % 1 Ω to 10 Ω · CMC 0,0035 % + 0,06 mΩ 10 Ω to 100 Ω · CMC 0,0031 % + 0,46 mΩ 100 Ω to 1 kΩ · CMC 0,0024 % + 3,8 mΩ 1 kΩ to 10 kΩ · CMC 0,0031 % + 0,038 Ω 10 kΩ to 100 kΩ · CMC 0,0031 % + 0,39 Ω 100 kΩ to 1 MΩ · CMC 0,003 % + 5,1 Ω 1 MΩ to 10 MΩ · CMC 0,022 % + 0,13 kΩ 10 MΩ to 100 MΩ · CMC 0,024 % 100 MΩ to 1 GΩ · CMC 0,06 % 1 GΩ to 10 GΩ · CMC 0,12 % 10 GΩ to 100 GΩ · CMC 0,5 %
DC resistance
Internal procedure; At permanent location (S) Internal procedures PP-LME-04 PP-LME-03
37 Shunts
Digital ohmmeters
Bridges
Fixed and variable resistors
Calibration — AC resistance
40 Hz to 1 kHz — 1 mΩ to 1 Ω · CMC 0,21 % 40 Hz to 1 kHz — 1 Ω to 1 MΩ · CMC 0,02 % 1 kHz — 1 mΩ to 1 Ω · CMC 0,19 % 1 kHz — 1 Ω to 10 Ω · CMC 0,06 % 1 kHz — 10 Ω to 100 kΩ · CMC 0,03 % 1 kHz — 100 kΩ to 1 MΩ · CMC 0,04 % 1 kHz — 1 MΩ to 10 MΩ · CMC 0,13 %
AC resistance
Internal procedure; At permanent location (S) Internal procedures PP-LME-04 PP-LME-01
38 Fixed and variable standard capacitors Calibration — Capacitance
1 kHz — 10 pF · CMC 0,2 % 1 kHz — 20 pF to 50 pF · CMC 0,1 % 1 kHz — 50 pF to 100 pF · CMC 0,06 % 1 kHz — 100 pF to 10 µF · CMC 0,02 % 1 kHz — 10 µF to 100 µF · CMC 0,04 % 1 kHz — 100 µF to 1200 µF · CMC 0,3 % 400 Hz — 10 pF to 50 pF · CMC 0,9 % 400 Hz — 50 pF to 1 nF · CMC 0,2 % 40 Hz to 1 kHz — 1 nF · CMC 0,21 % 40 Hz to 1 kHz — 10 nF to 100 µF · CMC 0,06 % 40 Hz to 1 kHz — 100 µF to 1200 µF · CMC 0,3 %
Capacitance
Internal procedure; At permanent location (S) Internal procedure PP-LME-02
39 Bridges,
Capacitance meters
Multimeters
Calibration — Capacitance
1 kHz — 50 pF to 100 pF · CMC 0,06 % 1 kHz — 100 pF to 10 µF · CMC 0,02 % 1 kHz — 10 µF to 100 µF · CMC 0,04 % 1 kHz — 100 µF to 1200 µF · CMC 0,3 % 400 Hz — 50 pF to 1 nF · CMC 0,2 % 40 Hz to 1 kHz — 1 nF · CMC 0,21 % 40 Hz to 1 kHz — 10 nF to 100 µF · CMC 0,06 % 40 Hz to 1 kHz — 100 µF to 1200 µF · CMC 0,3 %
Capacitance
Internal procedure; At permanent location (S) Internal procedure PP-LME-04
40 Fixed and variable standard inductors Calibration — Inductance
1 kHz — 10 µH to 100 µH · CMC 0,6% 1 kHz — 100 µH to 1 mH · CMC 0,07 % 1 kHz — 1 mH to 65 H · CMC 0,03 % 40 Hz to 1 kHz — 1 mH to 10 mH · CMC 0,6 % 40 Hz to 1 kHz — 10 mH to 100 mH · CMC 0,1 % 40 Hz to 1 kHz — 100 mH to 65 H · CMC 0,07 %
Inductance
Internal procedure; At permanent location (S) Internal procedure PP-LME-02
41 Bridges
Inductance meters
Calibration — Inductance
1 kHz — 10 µH to 100 µH · CMC 0,6 % 1 kHz — 100 µH to 1 mH · CMC 0,13 % 1 kHz — 1 mH to 15 H · CMC 0,07 % 40 Hz to 1 kHz — 1 mH to 10 mH · CMC 0,6 % 40 Hz to 1 kHz — 10 mH to 100 mH · CMC 0,1 % 40 Hz to 1 kHz — 100 mH to 15 H · CMC 0,07 %
Inductance
Internal procedure; At permanent location (S) Internal procedure PP-LME-04
42 Analogue and digital single-phase active power meters Calibration — AC power
40 Hz to 500 Hz; PF = 1; 1,3 V to 750 V; 0,005 A to 150 A — 6,5 mW to 112,5 kW · CMC 0,15 %
AC power
Internal procedure; At permanent location (S) Internal procedures PP-LME-03 PP-LME-04
43 Calibrators
Digital frequency meters
Multimeters
Calibration — Frequency
1 Hz to 1 kHz · CMC 0,004 % 1 kHz to 130 MHz · CMC 0,001 %
Frequency
Internal procedure; At permanent location (S) Internal procedures PP-LME-03 PP-LME-04

Reference standards (24)

PN-EN ISO 3650:2000
PP-LME-01
PP-LME-02
PP-LME-03
PP-LME-04
PP-LMM-01
PP-LMM-02
PP-LMM-03
PP-LMM-05
PP-LMM-06
PP-LMM-07
PP-LMM-08
PP-LMM-09
PP-LMM-10
PP-LMM-12
PP-LMM-13
PP-LMM-14
PP-LMM-15
PP-LMM-17
PP-LMM-18
PP-LMM-19
PP-LMM-20
PP-LMM-23
PP-LMM-30