{"lab":{"_id":"6afa3b9a8989a133b76445c7","accr_number":"AP 024","country":"PL","imported_at":"2026-11-15T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"ul. Chłopickiego 50, 04-257 Warszawa","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"16.09.2019","city":"Warszawa","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.","cycle_from":"03.12.2024","cycle_to":"19.12.2028","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"6.01","pl":"długość","en":"length","de":"Länge","zh":"长度","cs":"délka"},{"codes":"6.03","pl":"długość (geometria powierzchni)","en":"length (surface geometry)","de":"Länge (Oberflächengeometrie)","zh":"长度（表面几何）","cs":"délka (geometrie povrchu)"},{"codes":"7.01","pl":"napięcie DC","en":"DC voltage","de":"Gleichspannung","zh":"直流电压","cs":"stejnosměrné napětí (DC)"},{"codes":"7.02","pl":"prąd DC","en":"DC current","de":"DC-Strom","zh":"直流电流","cs":"proud DC"},{"codes":"7.03","pl":"napięcie AC","en":"AC voltage","de":"AC-Spannung","zh":"交流电压","cs":"napětí AC"},{"codes":"7.04","pl":"prąd AC","en":"AC current","de":"AC-Strom","zh":"交流电流","cs":"proud AC"},{"codes":"7.05","pl":"rezystancja DC","en":"DC resistance","de":"DC-Widerstand","zh":"直流电阻","cs":"odpor DC"},{"codes":"7.06","pl":"rezystancja AC","en":"AC resistance","de":"Wechselstromwiderstand","zh":"交流电阻","cs":"střídavý odpor"},{"codes":"7.08","pl":"indukcyjność","en":"inductance","de":"Induktivität","zh":"电感","cs":"indukčnost"},{"codes":"7.09","pl":"pojemność","en":"capacitance","de":"Kapazität","zh":"电容","cs":"kapacita"},{"codes":"7.13","pl":"moc AC","en":"AC power","de":"AC-Leistung","zh":"交流功率","cs":"výkon AC"},{"codes":"10.02","pl":"częstotliwość","en":"frequency","de":"Frequenz","zh":"频率","cs":"frekvence"}],"has_en":true,"has_zh":true,"issue":{"no":"22","date":"24.11.2025"},"issue_date":"24.11.2025","issue_number":"22","lab_division":"Laboratorium Metrologii","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[21.1124095,52.2499136]},"map_coord":[52.2499136,21.1124095],"map_geo":"nominatim-street","methods_count":43,"name":"Instytut Kolejnictwa","parse_date":"2026-11-15T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-15T12:00:00.000Z","pdf_files":["AP_024.pdf"],"scope_notes":[{"pl":"Wartość niepewności pomiaru dla CMC wyrażona w postaci równania Q[a; b] oznacza pierwiastek sumy kwadratów wyrazów w nawiasach: Q[a; b] = (a² + b²)^1/2.","en":"A CMC uncertainty value expressed as Q[a; b] means the root sum of squares of the terms in brackets: Q[a; b] = (a² + b²)^1/2."}],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: długość, długość (geometria powierzchni), napięcie DC, prąd DC, napięcie AC, prąd AC, rezystancja DC, rezystancja AC, indukcyjność, pojemność, moc AC, częstotliwość. W stałej lokalizacji (S).","search_text":"instytut kolejnictwa laboratorium metrologii ul. chłopickiego 50, 04-257 warszawa laboratorium wzorcujące. wielkości mierzone: długość, długość (geometria powierzchni), napięcie dc, prąd dc, napięcie ac, prąd ac, rezystancja dc, rezystancja ac, indukcyjność, pojemność, moc ac, częstotliwość. w stałej lokalizacji (s). ap 024 ap024 laboratorium wzorcujące wzorcowanie kalibracja length length (surface geometry) dc voltage dc current ac voltage ac current dc resistance ac resistance inductance capacitance ac power frequency instytut kolejnictwa laboratorium metrologii ul. chlopickiego 50, 04-257 warszawa laboratorium wzorcujace. wielkosci mierzone: dlugosc, dlugosc (geometria powierzchni), napiecie dc, prad dc, napiecie ac, prad ac, rezystancja dc, rezystancja ac, indukcyjnosc, pojemnosc, moc ac, czestotliwosc. w stalej lokalizacji (s). ap 024 ap024 laboratorium wzorcujace wzorcowanie kalibracja length length (surface geometry) dc voltage dc current ac voltage ac current dc resistance ac resistance inductance capacitance ac power frequency","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20024,podmiot.html","source_pdf_sha256":"2c634b5c1e538975c982699cf88fb79ae06b91481d213f50250988ec841f4a7a","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/15/43b80a2ba01c7eaacbddf13ce5162351/AP%20024.pdf","status":"active","updated_at":"2026-11-15T12:00:00.000Z","valid_from":"20-12-2000","valid_until":"19-12-2028","website":"www.ikolej.pl","lab_division_en":"Metrology Laboratory","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"lab_division_de":"Labor für Metrologie","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","lab_division_zh":"计量实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"lab_division_cs":"Laboratoř metrologie","pelny_cs":true},"methods":[{"_id":"63b50580e651aa86076b8dc1","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Czujniki analogowe o wartości działki elementarnej 0,01 mm","test_object_en":"Analogue dial gauges with a scale interval of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10,0 mm","cmc":"2,6 µm"},{"name":"","range":"0 mm do 25,0 mm","cmc":"3,7 µm"}],"parameters_en":[{"name":"","range":"0 mm to 10,0 mm","cmc":"2,6 µm"},{"name":"","range":"0 mm to 25,0 mm","cmc":"3,7 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 10,0 mm CMC 2,6 µm\n0 mm do 25,0 mm CMC 3,7 µm\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-15","norm_bases":["PP-LMM-15"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe o wartości działki elementarnej 0,01 mm Wzorcowanie — Długość\nZakres:\n0 mm do 10,0 mm CMC 2,6 µm\n0 mm do 25,0 mm CMC 3,7 µm\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-15 Czujniki analogowe o wartosci dzialki elementarnej 0,01 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 10,0 mm CMC 2,6 µm\n0 mm do 25,0 mm CMC 3,7 µm\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-15","search_en":"Analogue dial gauges with a scale interval of 0,01 mm Calibration — Length Internal procedure; Indirect method; At permanent location (S) Length Internal procedure Indirect method At permanent location (S) Internal procedure PP-LMM-15","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-15","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 10,0 mm","cmc":"2,6 µm"},{"name":"","range":"0 mm to 25,0 mm","cmc":"3,7 µm"}],"reference_de":"Internes Verfahren PP-LMM-15","regulatory_area_de":"Länge","search_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,01 mm Kalibrierung — Länge Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Länge Internes Verfahren Indirektes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-15","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 10,0 mm","cmc":"2,6 µm"},{"name":"","range":"0 mm to 25,0 mm","cmc":"3,7 µm"}],"reference_zh":"内部程序 PP-LMM-15","regulatory_area_zh":"长度","search_zh":"分度值 0,01 mm 的模拟指示表 校准 — 长度 内部程序；间接方法；固定地点（S） 长度 内部程序 间接法 在固定地点 (S) 内部程序 PP-LMM-15","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"分度值 0,01 mm 的模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 10,0 mm","cmc":"2,6 µm"},{"name":"","range":"0 mm to 25,0 mm","cmc":"3,7 µm"}],"reference_cs":"Vnitřní postup PP-LMM-15","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry s hodnotou dílku 0,01 mm Kalibrace — Délka Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-15","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry s hodnotou dílku 0,01 mm"},{"_id":"2b038819860d393acd36f9e6","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Czujniki analogowe o wartości działki elementarnej 0,001 mm","test_object_en":"Analogue dial gauges with a scale interval of 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 1,0 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm do 5,0 mm","cmc":"3,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 1,0 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm to 5,0 mm","cmc":"3,5 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 1,0 mm CMC 2,0 µm\n0 mm do 5,0 mm CMC 3,5 µm\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-15","norm_bases":["PP-LMM-15"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe o wartości działki elementarnej 0,001 mm Wzorcowanie — Długość\nZakres:\n0 mm do 1,0 mm CMC 2,0 µm\n0 mm do 5,0 mm CMC 3,5 µm\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-15 Czujniki analogowe o wartosci dzialki elementarnej 0,001 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 1,0 mm CMC 2,0 µm\n0 mm do 5,0 mm CMC 3,5 µm\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-15","search_en":"Analogue dial gauges with a scale interval of 0,001 mm Calibration — Length Internal procedure; Indirect method; At permanent location (S) Length Internal procedure Indirect method At permanent location (S) Internal procedure PP-LMM-15","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-15","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 1,0 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm to 5,0 mm","cmc":"3,5 µm"}],"reference_de":"Internes Verfahren PP-LMM-15","regulatory_area_de":"Länge","search_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,001 mm Kalibrierung — Länge Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Länge Internes Verfahren Indirektes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-15","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 1,0 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm to 5,0 mm","cmc":"3,5 µm"}],"reference_zh":"内部程序 PP-LMM-15","regulatory_area_zh":"长度","search_zh":"分度值 0,001 mm 的模拟指示表 校准 — 长度 内部程序；间接方法；固定地点（S） 长度 内部程序 间接法 在固定地点 (S) 内部程序 PP-LMM-15","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"分度值 0,001 mm 的模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 1,0 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm to 5,0 mm","cmc":"3,5 µm"}],"reference_cs":"Vnitřní postup PP-LMM-15","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry s hodnotou dílku 0,001 mm Kalibrace — Délka Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-15","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry s hodnotou dílku 0,001 mm"},{"_id":"193f2bf15576e6ad193c21ba","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Czujniki analogowe z uchylnym trzpieniem","test_object_en":"Lever-type analogue dial gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"-1 mm do 1 mm","cmc":"2,6 µm"}],"parameters_en":[{"name":"","range":"-1 mm to 1 mm","cmc":"2,6 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n-1 mm do 1 mm CMC 2,6 µm\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-15","norm_bases":["PP-LMM-15"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe z uchylnym trzpieniem Wzorcowanie — Długość\n-1 mm do 1 mm CMC 2,6 µm\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-15 Czujniki analogowe z uchylnym trzpieniem Wzorcowanie — Dlugosc\n-1 mm do 1 mm CMC 2,6 µm\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-15","search_en":"Lever-type analogue dial gauges Calibration — Length Internal procedure; Indirect method; At permanent location (S) Length Internal procedure Indirect method At permanent location (S) Internal procedure PP-LMM-15","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-15","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"-1 mm to 1 mm","cmc":"2,6 µm"}],"reference_de":"Internes Verfahren PP-LMM-15","regulatory_area_de":"Länge","search_de":"Analoge Fühlhebelmessgeräte Kalibrierung — Länge Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Länge Internes Verfahren Indirektes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-15","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Fühlhebelmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"-1 mm to 1 mm","cmc":"2,6 µm"}],"reference_zh":"内部程序 PP-LMM-15","regulatory_area_zh":"长度","search_zh":"指针式杠杆千分表 校准 — 长度 内部程序；间接方法；固定地点（S） 长度 内部程序 间接法 在固定地点 (S) 内部程序 PP-LMM-15","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"指针式杠杆千分表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"-1 mm to 1 mm","cmc":"2,6 µm"}],"reference_cs":"Vnitřní postup PP-LMM-15","regulatory_area_cs":"Délka","search_cs":"Analogové páčkové úchylkoměry Kalibrace — Délka Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-15","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové páčkové úchylkoměry"},{"_id":"40ef14df8028ea4023caf03a","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,01 mm","test_object_en":"Digital dial gauges with a resolution of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 12,7 mm","cmc":"8,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"8,8 µm"}],"parameters_en":[{"name":"","range":"0 mm to 12,7 mm","cmc":"8,8 µm"},{"name":"","range":"0 mm to 25,4 mm","cmc":"8,8 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 8,8 µm\n0 mm do 25,4 mm CMC 8,8 µm\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-15","norm_bases":["PP-LMM-15"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,01 mm Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 8,8 µm\n0 mm do 25,4 mm CMC 8,8 µm\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-15 Czujniki cyfrowe o rozdzielczosci 0,01 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 12,7 mm CMC 8,8 µm\n0 mm do 25,4 mm CMC 8,8 µm\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-15","search_en":"Digital dial gauges with a resolution of 0,01 mm Calibration — Length Internal procedure; Indirect method; At permanent location (S) Length Internal procedure Indirect method At permanent location (S) Internal procedure PP-LMM-15","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-15","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 12,7 mm","cmc":"8,8 µm"},{"name":"","range":"0 mm to 25,4 mm","cmc":"8,8 µm"}],"reference_de":"Internes Verfahren PP-LMM-15","regulatory_area_de":"Länge","search_de":"Digitale Messtaster mit einer Auflösung von 0,01 mm Kalibrierung — Länge Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Länge Internes Verfahren Indirektes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-15","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Messtaster mit einer Auflösung von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 12,7 mm","cmc":"8,8 µm"},{"name":"","range":"0 mm to 25,4 mm","cmc":"8,8 µm"}],"reference_zh":"内部程序 PP-LMM-15","regulatory_area_zh":"长度","search_zh":"分辨率 0,01 mm 的数字测微表 校准 — 长度 内部程序；间接方法；固定地点（S） 长度 内部程序 间接法 在固定地点 (S) 内部程序 PP-LMM-15","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"分辨率 0,01 mm 的数字测微表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 12,7 mm","cmc":"8,8 µm"},{"name":"","range":"0 mm to 25,4 mm","cmc":"8,8 µm"}],"reference_cs":"Vnitřní postup PP-LMM-15","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,01 mm Kalibrace — Délka Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-15","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,01 mm"},{"_id":"e11a41239601c0cb2859a0a7","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,001 mm","test_object_en":"Digital dial gauges with a resolution of 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 12,7 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,4 µm"}],"parameters_en":[{"name":"","range":"0 mm to 12,7 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm to 25,4 mm","cmc":"3,4 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 2,1 µm\n0 mm do 25,4 mm CMC 3,4 µm\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-15","norm_bases":["PP-LMM-15"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,001 mm Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 2,1 µm\n0 mm do 25,4 mm CMC 3,4 µm\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-15 Czujniki cyfrowe o rozdzielczosci 0,001 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 12,7 mm CMC 2,1 µm\n0 mm do 25,4 mm CMC 3,4 µm\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-15","search_en":"Digital dial gauges with a resolution of 0,001 mm Calibration — Length Internal procedure; Indirect method; At permanent location (S) Length Internal procedure Indirect method At permanent location (S) Internal procedure PP-LMM-15","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-15","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 12,7 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm to 25,4 mm","cmc":"3,4 µm"}],"reference_de":"Internes Verfahren PP-LMM-15","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,001 mm Kalibrierung — Länge Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Länge Internes Verfahren Indirektes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-15","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 12,7 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm to 25,4 mm","cmc":"3,4 µm"}],"reference_zh":"内部程序 PP-LMM-15","regulatory_area_zh":"长度","search_zh":"分辨力 0,001 mm 的数显指示表 校准 — 长度 内部程序；间接方法；固定地点（S） 长度 内部程序 间接法 在固定地点 (S) 内部程序 PP-LMM-15","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"分辨力 0,001 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 12,7 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm to 25,4 mm","cmc":"3,4 µm"}],"reference_cs":"Vnitřní postup PP-LMM-15","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,001 mm Kalibrace — Délka Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-15","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,001 mm"},{"_id":"faa966a25d51dce88f398371","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Głębokościomierze mikrometryczne","test_object_en":"Micrometer depth gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"3,2 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"3,2 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 2,1 µm\n50 mm do 100 mm CMC 3,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-10","norm_bases":["PP-LMM-10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze mikrometryczne Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 2,1 µm\n50 mm do 100 mm CMC 3,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-10 Glebokosciomierze mikrometryczne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 50 mm CMC 2,1 µm\n50 mm do 100 mm CMC 3,2 µm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-10","search_en":"Micrometer depth gauges Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) Internal procedure PP-LMM-10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-10","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"3,2 µm"}],"reference_de":"Internes Verfahren PP-LMM-10","regulatory_area_de":"Länge","search_de":"Mikrometer-Tiefenmessgeräte Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-10","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Mikrometer-Tiefenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"3,2 µm"}],"reference_zh":"内部程序 PP-LMM-10","regulatory_area_zh":"长度","search_zh":"深度千分尺 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) 内部程序 PP-LMM-10","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"深度千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"3,2 µm"}],"reference_cs":"Vnitřní postup PP-LMM-10","regulatory_area_cs":"Délka","search_cs":"Mikrometrické hloubkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-10","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometrické hloubkoměry"},{"_id":"7418124cee125226bf42a955","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Głębokościomierze suwmiarkowe","test_object_en":"Vernier depth gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm do 600 mm","cmc":"0,02 mm"}],"parameters_en":[{"name":"","range":"0 mm to 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm to 600 mm","cmc":"0,02 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 200 mm CMC 0,01 mm\n0 mm do 600 mm CMC 0,02 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-08","norm_bases":["PP-LMM-08"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze suwmiarkowe Wzorcowanie — Długość\nZakres:\n0 mm do 200 mm CMC 0,01 mm\n0 mm do 600 mm CMC 0,02 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-08 Glebokosciomierze suwmiarkowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 200 mm CMC 0,01 mm\n0 mm do 600 mm CMC 0,02 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-08","search_en":"Vernier depth gauges Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) Internal procedure PP-LMM-08","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-08","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm bis 600 mm","cmc":"0,02 mm"}],"reference_de":"Internes Verfahren PP-LMM-08","regulatory_area_de":"Länge","search_de":"Tiefenmessschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-08","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Tiefenmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm 至 600 mm","cmc":"0,02 mm"}],"reference_zh":"内部程序 PP-LMM-08","regulatory_area_zh":"长度","search_zh":"深度游标卡尺 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) 内部程序 PP-LMM-08","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"深度游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm do 600 mm","cmc":"0,02 mm"}],"reference_cs":"Vnitřní postup PP-LMM-08","regulatory_area_cs":"Délka","search_cs":"Posuvné hloubkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-08","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Posuvné hloubkoměry"},{"_id":"06c4c1a7f6bb9208e31e16e5","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Mikrometry zewnętrzne","test_object_en":"External micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"3,2 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"4,4 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"5,7 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"7,0 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"8,3 µm"},{"name":"","range":"300 mm do 350 mm","cmc":"9,7 µm"},{"name":"","range":"350 mm do 400 mm","cmc":"11 µm"},{"name":"","range":"400 mm do 450 mm","cmc":"12 µm"},{"name":"","range":"450 mm do 500 mm","cmc":"14 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"3,2 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"4,4 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"5,7 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"7,0 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"8,3 µm"},{"name":"","range":"300 mm do 350 mm","cmc":"9,7 µm"},{"name":"","range":"350 mm do 400 mm","cmc":"11 µm"},{"name":"","range":"400 mm do 450 mm","cmc":"12 µm"},{"name":"","range":"450 mm do 500 mm","cmc":"14 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 2,1 µm\n50 mm do 100 mm CMC 3,2 µm\n100 mm do 150 mm CMC 4,4 µm\n150 mm do 200 mm CMC 5,7 µm\n200 mm do 250 mm CMC 7,0 µm\n250 mm do 300 mm CMC 8,3 µm\n300 mm do 350 mm CMC 9,7 µm\n350 mm do 400 mm CMC 11 µm\n400 mm do 450 mm CMC 12 µm\n450 mm do 500 mm CMC 14 µm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-09","norm_bases":["PP-LMM-09"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mikrometry zewnętrzne Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 2,1 µm\n50 mm do 100 mm CMC 3,2 µm\n100 mm do 150 mm CMC 4,4 µm\n150 mm do 200 mm CMC 5,7 µm\n200 mm do 250 mm CMC 7,0 µm\n250 mm do 300 mm CMC 8,3 µm\n300 mm do 350 mm CMC 9,7 µm\n350 mm do 400 mm CMC 11 µm\n400 mm do 450 mm CMC 12 µm\n450 mm do 500 mm CMC 14 µm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-09 Mikrometry zewnetrzne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 50 mm CMC 2,1 µm\n50 mm do 100 mm CMC 3,2 µm\n100 mm do 150 mm CMC 4,4 µm\n150 mm do 200 mm CMC 5,7 µm\n200 mm do 250 mm CMC 7,0 µm\n250 mm do 300 mm CMC 8,3 µm\n300 mm do 350 mm CMC 9,7 µm\n350 mm do 400 mm CMC 11 µm\n400 mm do 450 mm CMC 12 µm\n450 mm do 500 mm CMC 14 µm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-09","search_en":"External micrometers Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) Internal procedure PP-LMM-09","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-09","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"3,2 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"4,4 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"5,7 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"7,0 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"8,3 µm"},{"name":"","range":"300 mm do 350 mm","cmc":"9,7 µm"},{"name":"","range":"350 mm do 400 mm","cmc":"11 µm"},{"name":"","range":"400 mm do 450 mm","cmc":"12 µm"},{"name":"","range":"450 mm do 500 mm","cmc":"14 µm"}],"reference_de":"Internes Verfahren PP-LMM-09","regulatory_area_de":"Länge","search_de":"Bügelmessschrauben Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-09","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Bügelmessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"3,2 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"4,4 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"5,7 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"7,0 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"8,3 µm"},{"name":"","range":"300 mm do 350 mm","cmc":"9,7 µm"},{"name":"","range":"350 mm do 400 mm","cmc":"11 µm"},{"name":"","range":"400 mm do 450 mm","cmc":"12 µm"},{"name":"","range":"450 mm do 500 mm","cmc":"14 µm"}],"reference_zh":"内部程序 PP-LMM-09","regulatory_area_zh":"长度","search_zh":"外径千分尺 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) 内部程序 PP-LMM-09","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"外径千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"3,2 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"4,4 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"5,7 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"7,0 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"8,3 µm"},{"name":"","range":"300 mm do 350 mm","cmc":"9,7 µm"},{"name":"","range":"350 mm do 400 mm","cmc":"11 µm"},{"name":"","range":"400 mm do 450 mm","cmc":"12 µm"},{"name":"","range":"450 mm do 500 mm","cmc":"14 µm"}],"reference_cs":"Vnitřní postup PP-LMM-09","regulatory_area_cs":"Délka","search_cs":"Mikrometry pro vnější měření Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-09","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometry pro vnější měření"},{"_id":"bebcf42690f3527143a50ea3","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Mikrometry z wbudowanym czujnikiem","test_object_en":"Indicating micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"25 mm do 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"2,9 µm"}],"parameters_en":[{"name":"","range":"25 mm to 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"2,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n25 mm do 50 mm CMC 1,6 µm\n50 mm do 100 mm CMC 2,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-13","norm_bases":["PP-LMM-13"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mikrometry z wbudowanym czujnikiem Wzorcowanie — Długość\nZakres:\n25 mm do 50 mm CMC 1,6 µm\n50 mm do 100 mm CMC 2,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-13 Mikrometry z wbudowanym czujnikiem Wzorcowanie — Dlugosc\nZakres:\n25 mm do 50 mm CMC 1,6 µm\n50 mm do 100 mm CMC 2,9 µm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-13","search_en":"Indicating micrometers Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) Internal procedure PP-LMM-13","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-13","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"25 mm bis 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"2,9 µm"}],"reference_de":"Internes Verfahren PP-LMM-13","regulatory_area_de":"Länge","search_de":"Feinzeigermessschrauben Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-13","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Feinzeigermessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"25 mm 至 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"2,9 µm"}],"reference_zh":"内部程序 PP-LMM-13","regulatory_area_zh":"长度","search_zh":"带表千分尺 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) 内部程序 PP-LMM-13","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"带表千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"25 mm do 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"2,9 µm"}],"reference_cs":"Vnitřní postup PP-LMM-13","regulatory_area_cs":"Délka","search_cs":"Mikrometry s vestavěným úchylkoměrem Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-13","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometry s vestavěným úchylkoměrem"},{"_id":"daca925f32a88066396dcb12","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Płytki wzorcowe (klasy 0, 1, 2)","test_object_en":"Gauge blocks (classes 0, 1, 2)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- stalowe","range":"0,5 mm do 100 mm","cmc":"Q[0,07; 1,08∙L] µm"},{"name":"- ceramiczne","range":"0,5 mm do 100 mm","cmc":"Q[0,08; 1,44∙L] µm"}],"parameters_en":[{"name":"- steel","range":"0,5 mm to 100 mm","cmc":"Q[0,07; 1,08∙L] µm"},{"name":"- ceramic","range":"0,5 mm to 100 mm","cmc":"Q[0,08; 1,44∙L] µm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz komparatora dwuczujnikowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparison method using gauge blocks and a two-probe comparator; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem płytek wzorcowych oraz komparatora dwuczujnikowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparison method using gauge blocks and a two-probe comparator","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- stalowe 0,5 mm do 100 mm CMC Q[0,07; 1,08∙L] µm\n- ceramiczne 0,5 mm do 100 mm CMC Q[0,08; 1,44∙L] µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz komparatora dwuczujnikowego; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-01 w oparciu o PN-EN ISO 3650:2000","norm_bases":["PP-LMM-01","PN-EN ISO 3650:2000"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L – wielkość mierzona (m)","note_en":"L – measured quantity (m)","search_text":"Płytki wzorcowe (klasy 0, 1, 2) Wzorcowanie — Długość\nZakres:\n- stalowe 0,5 mm do 100 mm CMC Q[0,07; 1,08∙L] µm\n- ceramiczne 0,5 mm do 100 mm CMC Q[0,08; 1,44∙L] µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz komparatora dwuczujnikowego; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-01 w oparciu o PN-EN ISO 3650:2000 Plytki wzorcowe (klasy 0, 1, 2) Wzorcowanie — Dlugosc\nZakres:\n- stalowe 0,5 mm do 100 mm CMC Q[0,07; 1,08∙L] µm\n- ceramiczne 0,5 mm do 100 mm CMC Q[0,08; 1,44∙L] µm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem plytek wzorcowych oraz komparatora dwuczujnikowego; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-01 w oparciu o PN-EN ISO 3650:2000","search_en":"Gauge blocks (classes 0, 1, 2) Calibration — Length Internal procedure; Comparison method using gauge blocks and a two-probe comparator; At permanent location (S) Length Internal procedure Comparison method using gauge blocks and a two-probe comparator At permanent location (S) - steel - ceramic Internal procedure PP-LMM-01 based on PN-EN ISO 3650:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-01 based on PN-EN ISO 3650:2000","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- aus Stahl","range":"0,5 mm to 100 mm","cmc":"Q[0,07; 1,08∙L] µm"},{"name":"- keramisch","range":"0,5 mm to 100 mm","cmc":"Q[0,08; 1,44∙L] µm"}],"reference_de":"Internes Verfahren PP-LMM-01 auf Grundlage von PN-EN ISO 3650:2000","regulatory_area_de":"Länge","search_de":"Parallelendmaße (Klassen 0, 1, 2) Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit Parallelendmaßen und einem Zweitaster-Komparator; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit Parallelendmaßen und einem Zweitaster-Komparator Am festen Standort (S) - aus Stahl - keramisch Internes Verfahren PP-LMM-01 auf Grundlage von PN-EN ISO 3650:2000","technique_de":"Internes Verfahren; Vergleichsverfahren mit Parallelendmaßen und einem Zweitaster-Komparator; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit Parallelendmaßen und einem Zweitaster-Komparator","Am festen Standort (S)"],"test_object_de":"Parallelendmaße (Klassen 0, 1, 2)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 钢制","range":"0,5 mm to 100 mm","cmc":"Q[0,07; 1,08∙L] µm"},{"name":"- 陶瓷","range":"0,5 mm to 100 mm","cmc":"Q[0,08; 1,44∙L] µm"}],"reference_zh":"内部程序 PP-LMM-01 依据PN-EN ISO 3650:2000","regulatory_area_zh":"长度","search_zh":"量块（0、1、2 级） 校准 — 长度 内部程序；使用量块和双测头比较仪的比较法；在固定地点 (S) 长度 内部程序 使用量块和双测头比较仪的比较法 在固定地点 (S) - 钢制 - 陶瓷 内部程序 PP-LMM-01 依据PN-EN ISO 3650:2000","technique_zh":"内部程序；使用量块和双测头比较仪的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用量块和双测头比较仪的比较法","在固定地点 (S)"],"test_object_zh":"量块（0、1、2 级）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- ocelové","range":"0,5 mm to 100 mm","cmc":"Q[0,07; 1,08∙L] µm"},{"name":"- keramické","range":"0,5 mm to 100 mm","cmc":"Q[0,08; 1,44∙L] µm"}],"reference_cs":"Vnitřní postup PP-LMM-01 na základě PN-EN ISO 3650:2000","regulatory_area_cs":"Délka","search_cs":"Koncové měrky (třídy 0, 1, 2) Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím koncových měrek a dvousnímačového komparátoru; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím koncových měrek a dvousnímačového komparátoru Ve stálé lokalitě (S) - ocelové - keramické Vnitřní postup PP-LMM-01 na základě PN-EN ISO 3650:2000","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím koncových měrek a dvousnímačového komparátoru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím koncových měrek a dvousnímačového komparátoru","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky (třídy 0, 1, 2)"},{"_id":"463fa881a9be5cb65c9d70fb","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Płytki wzorcowe (klasy 0, 1, 2)","test_object_en":"Gauge blocks (classes 0, 1, 2)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- stalowe","range":"125 mm do 500 mm","cmc":"Q[0,17; 1,10∙L] µm"},{"name":"- ceramiczne","range":"125 mm do 500 mm","cmc":"Q[0,16; 1,44∙L] µm"}],"parameters_en":[{"name":"- steel","range":"125 mm to 500 mm","cmc":"Q[0,17; 1,10∙L] µm"},{"name":"- ceramic","range":"125 mm to 500 mm","cmc":"Q[0,16; 1,44∙L] µm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz optimetru; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparison method using gauge blocks and an optimeter; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem płytek wzorcowych oraz optimetru","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparison method using gauge blocks and an optimeter","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- stalowe 125 mm do 500 mm CMC Q[0,17; 1,10∙L] µm\n- ceramiczne 125 mm do 500 mm CMC Q[0,16; 1,44∙L] µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz optimetru; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-02 w oparciu o PN-EN ISO 3650:2000","norm_bases":["PP-LMM-02","PN-EN ISO 3650:2000"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L – wielkość mierzona (m)","note_en":"L – measured quantity (m)","search_text":"Płytki wzorcowe (klasy 0, 1, 2) Wzorcowanie — Długość\nZakres:\n- stalowe 125 mm do 500 mm CMC Q[0,17; 1,10∙L] µm\n- ceramiczne 125 mm do 500 mm CMC Q[0,16; 1,44∙L] µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz optimetru; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-02 w oparciu o PN-EN ISO 3650:2000 Plytki wzorcowe (klasy 0, 1, 2) Wzorcowanie — Dlugosc\nZakres:\n- stalowe 125 mm do 500 mm CMC Q[0,17; 1,10∙L] µm\n- ceramiczne 125 mm do 500 mm CMC Q[0,16; 1,44∙L] µm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem plytek wzorcowych oraz optimetru; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-02 w oparciu o PN-EN ISO 3650:2000","search_en":"Gauge blocks (classes 0, 1, 2) Calibration — Length Internal procedure; Comparison method using gauge blocks and an optimeter; At permanent location (S) Length Internal procedure Comparison method using gauge blocks and an optimeter At permanent location (S) - steel - ceramic Internal procedure PP-LMM-02 based on PN-EN ISO 3650:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-02 based on PN-EN ISO 3650:2000","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- aus Stahl","range":"125 mm to 500 mm","cmc":"Q[0,17; 1,10∙L] µm"},{"name":"- keramisch","range":"125 mm to 500 mm","cmc":"Q[0,16; 1,44∙L] µm"}],"reference_de":"Internes Verfahren PP-LMM-02 auf Grundlage von PN-EN ISO 3650:2000","regulatory_area_de":"Länge","search_de":"Parallelendmaße (Klassen 0, 1, 2) Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit Parallelendmaßen und einem Optimeter; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit Parallelendmaßen und einem Optimeter Am festen Standort (S) - aus Stahl - keramisch Internes Verfahren PP-LMM-02 auf Grundlage von PN-EN ISO 3650:2000","technique_de":"Internes Verfahren; Vergleichsverfahren mit Parallelendmaßen und einem Optimeter; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit Parallelendmaßen und einem Optimeter","Am festen Standort (S)"],"test_object_de":"Parallelendmaße (Klassen 0, 1, 2)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 钢制","range":"125 mm to 500 mm","cmc":"Q[0,17; 1,10∙L] µm"},{"name":"- 陶瓷","range":"125 mm to 500 mm","cmc":"Q[0,16; 1,44∙L] µm"}],"reference_zh":"内部程序 PP-LMM-02 依据PN-EN ISO 3650:2000","regulatory_area_zh":"长度","search_zh":"量块（0、1、2 级） 校准 — 长度 内部程序；使用量块和光学计的比较法；在固定地点 (S) 长度 内部程序 使用量块和光学计的比较法 在固定地点 (S) - 钢制 - 陶瓷 内部程序 PP-LMM-02 依据PN-EN ISO 3650:2000","technique_zh":"内部程序；使用量块和光学计的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用量块和光学计的比较法","在固定地点 (S)"],"test_object_zh":"量块（0、1、2 级）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- ocelové","range":"125 mm to 500 mm","cmc":"Q[0,17; 1,10∙L] µm"},{"name":"- keramické","range":"125 mm to 500 mm","cmc":"Q[0,16; 1,44∙L] µm"}],"reference_cs":"Vnitřní postup PP-LMM-02 na základě PN-EN ISO 3650:2000","regulatory_area_cs":"Délka","search_cs":"Koncové měrky (třídy 0, 1, 2) Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím koncových měrek a optimetru; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím koncových měrek a optimetru Ve stálé lokalitě (S) - ocelové - keramické Vnitřní postup PP-LMM-02 na základě PN-EN ISO 3650:2000","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím koncových měrek a optimetru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím koncových měrek a optimetru","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky (třídy 0, 1, 2)"},{"_id":"15f276b3c83b4f21c440ee31","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Sprawdziany specjalne","test_object_en":"Special gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 200 mm","cmc":"0,03 mm"},{"name":"","range":"0 mm do 500 mm","cmc":"0,04 mm"},{"name":"","range":"0 mm do 1000 mm","cmc":"0,05 mm"}],"parameters_en":[{"name":"","range":"0 mm to 200 mm","cmc":"0,03 mm"},{"name":"","range":"0 mm do 500 mm","cmc":"0,04 mm"},{"name":"","range":"0 mm to 1000 mm","cmc":"0,05 mm"}],"technique":"Procedura wewnętrzna; Pomiar (wymiary zewnętrzne i wewnętrzne). Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Measurement (external and internal dimensions). Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Pomiar (wymiary zewnętrzne i wewnętrzne). Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Measurement (external and internal dimensions). Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 200 mm CMC 0,03 mm\n0 mm do 500 mm CMC 0,04 mm\n0 mm do 1000 mm CMC 0,05 mm\nProcedura wewnętrzna; Pomiar (wymiary zewnętrzne i wewnętrzne). Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-30","norm_bases":["PP-LMM-30"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany specjalne Wzorcowanie — Długość\nZakres:\n0 mm do 200 mm CMC 0,03 mm\n0 mm do 500 mm CMC 0,04 mm\n0 mm do 1000 mm CMC 0,05 mm\nProcedura wewnętrzna; Pomiar (wymiary zewnętrzne i wewnętrzne). Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-30 Sprawdziany specjalne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 200 mm CMC 0,03 mm\n0 mm do 500 mm CMC 0,04 mm\n0 mm do 1000 mm CMC 0,05 mm\nProcedura wewnetrzna; Pomiar (wymiary zewnetrzne i wewnetrzne). Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-30","search_en":"Special gauges Calibration — Length Internal procedure; Measurement (external and internal dimensions). Direct method; At permanent location (S) Length Internal procedure Measurement (external and internal dimensions). Direct method At permanent location (S) Internal procedure PP-LMM-30","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-30","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 200 mm","cmc":"0,03 mm"},{"name":"","range":"0 mm do 500 mm","cmc":"0,04 mm"},{"name":"","range":"0 mm bis 1000 mm","cmc":"0,05 mm"}],"reference_de":"Internes Verfahren PP-LMM-30","regulatory_area_de":"Länge","search_de":"Sonderlehren Kalibrierung — Länge Internes Verfahren; Messung (Außen- und Innenmaße). Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Messung (Außen- und Innenmaße). Direktes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-30","technique_de":"Internes Verfahren; Messung (Außen- und Innenmaße). Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Messung (Außen- und Innenmaße). Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Sonderlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 200 mm","cmc":"0,03 mm"},{"name":"","range":"0 mm do 500 mm","cmc":"0,04 mm"},{"name":"","range":"0 mm 至 1000 mm","cmc":"0,05 mm"}],"reference_zh":"内部程序 PP-LMM-30","regulatory_area_zh":"长度","search_zh":"专用量规 校准 — 长度 内部程序；测量（外尺寸和内尺寸）。直接法；在固定地点 (S) 长度 内部程序 测量（外尺寸和内尺寸）。直接法 在固定地点 (S) 内部程序 PP-LMM-30","technique_zh":"内部程序；测量（外尺寸和内尺寸）。直接法；在固定地点 (S)","techniques_zh":["内部程序","测量（外尺寸和内尺寸）。直接法","在固定地点 (S)"],"test_object_zh":"专用量规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 200 mm","cmc":"0,03 mm"},{"name":"","range":"0 mm do 500 mm","cmc":"0,04 mm"},{"name":"","range":"0 mm do 1000 mm","cmc":"0,05 mm"}],"reference_cs":"Vnitřní postup PP-LMM-30","regulatory_area_cs":"Délka","search_cs":"Speciální kalibry Kalibrace — Délka Vnitřní postup; Měření (vnější a vnitřní rozměry). Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Měření (vnější a vnitřní rozměry). Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-30","technique_cs":"Vnitřní postup; Měření (vnější a vnitřní rozměry). Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Měření (vnější a vnitřní rozměry). Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Speciální kalibry"},{"_id":"e82a5fb24a17e75026876939","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Przyrządy do pomiaru odległości wewnętrznych płaszczyzn kół zestawów kołowych","test_object_en":"Instruments for measuring the distance between inner faces of wheelset wheels","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"1330 mm do 1465 mm","cmc":"0,20 mm"}],"parameters_en":[{"name":"","range":"1330 mm to 1465 mm","cmc":"0,20 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n1330 mm do 1465 mm CMC 0,20 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-19","norm_bases":["PP-LMM-19"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przyrządy do pomiaru odległości wewnętrznych płaszczyzn kół zestawów kołowych Wzorcowanie — Długość\n1330 mm do 1465 mm CMC 0,20 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-19 Przyrzady do pomiaru odleglosci wewnetrznych plaszczyzn kol zestawow kolowych Wzorcowanie — Dlugosc\n1330 mm do 1465 mm CMC 0,20 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-19","search_en":"Instruments for measuring the distance between inner faces of wheelset wheels Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) Internal procedure PP-LMM-19","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-19","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"1330 mm to 1465 mm","cmc":"0,20 mm"}],"reference_de":"Internes Verfahren PP-LMM-19","regulatory_area_de":"Länge","search_de":"Messgeräte für den Abstand der Radinnenflächen von Radsätzen Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-19","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Messgeräte für den Abstand der Radinnenflächen von Radsätzen","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"1330 mm to 1465 mm","cmc":"0,20 mm"}],"reference_zh":"内部程序 PP-LMM-19","regulatory_area_zh":"长度","search_zh":"轮对车轮内侧面距离测量仪 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) 内部程序 PP-LMM-19","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"轮对车轮内侧面距离测量仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"1330 mm to 1465 mm","cmc":"0,20 mm"}],"reference_cs":"Vnitřní postup PP-LMM-19","regulatory_area_cs":"Délka","search_cs":"Přístroje pro měření vzdálenosti vnitřních čel kol dvojkolí Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-19","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Přístroje pro měření vzdálenosti vnitřních čel kol dvojkolí"},{"_id":"27fa1a453f6a659a49d9ac9a","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Przyrządy do pomiaru średnicy okręgu tocznego kół zestawów kołowych","test_object_en":"Instruments for measuring the running circle diameter of wheelset wheels","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"800 mm do 1050 mm","cmc":"0,04 mm"}],"parameters_en":[{"name":"","range":"800 mm to 1050 mm","cmc":"0,04 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n800 mm do 1050 mm CMC 0,04 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-18","norm_bases":["PP-LMM-18"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przyrządy do pomiaru średnicy okręgu tocznego kół zestawów kołowych Wzorcowanie — Długość\n800 mm do 1050 mm CMC 0,04 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-18 Przyrzady do pomiaru srednicy okregu tocznego kol zestawow kolowych Wzorcowanie — Dlugosc\n800 mm do 1050 mm CMC 0,04 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-18","search_en":"Instruments for measuring the running circle diameter of wheelset wheels Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) Internal procedure PP-LMM-18","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-18","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"800 mm to 1050 mm","cmc":"0,04 mm"}],"reference_de":"Internes Verfahren PP-LMM-18","regulatory_area_de":"Länge","search_de":"Messgeräte für den Laufkreisdurchmesser von Radsatzrädern Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-18","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Messgeräte für den Laufkreisdurchmesser von Radsatzrädern","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"800 mm to 1050 mm","cmc":"0,04 mm"}],"reference_zh":"内部程序 PP-LMM-18","regulatory_area_zh":"长度","search_zh":"轮对车轮滚动圆直径测量仪 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) 内部程序 PP-LMM-18","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"轮对车轮滚动圆直径测量仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"800 mm to 1050 mm","cmc":"0,04 mm"}],"reference_cs":"Vnitřní postup PP-LMM-18","regulatory_area_cs":"Délka","search_cs":"Přístroje pro měření průměru jízdní kružnice kol dvojkolí Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-18","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Přístroje pro měření průměru jízdní kružnice kol dvojkolí"},{"_id":"a9fdb238bff0fa1616a92195","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Przyrządy do pomiaru wysokości osi zderzaka nad główką szyny","test_object_en":"Instruments for measuring the buffer axis height above the rail head","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"900 mm do 1150 mm","cmc":"0,40 mm"}],"parameters_en":[{"name":"","range":"900 mm to 1150 mm","cmc":"0,40 mm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparison method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparison method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n900 mm do 1150 mm CMC 0,40 mm\nProcedura wewnętrzna; Metoda porównawcza; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-20","norm_bases":["PP-LMM-20"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przyrządy do pomiaru wysokości osi zderzaka nad główką szyny Wzorcowanie — Długość\n900 mm do 1150 mm CMC 0,40 mm\nProcedura wewnętrzna; Metoda porównawcza; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-20 Przyrzady do pomiaru wysokosci osi zderzaka nad glowka szyny Wzorcowanie — Dlugosc\n900 mm do 1150 mm CMC 0,40 mm\nProcedura wewnetrzna; Metoda porownawcza; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-20","search_en":"Instruments for measuring the buffer axis height above the rail head Calibration — Length Internal procedure; Comparison method; At permanent location (S) Length Internal procedure Comparison method At permanent location (S) Internal procedure PP-LMM-20","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-20","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"900 mm to 1150 mm","cmc":"0,40 mm"}],"reference_de":"Internes Verfahren PP-LMM-20","regulatory_area_de":"Länge","search_de":"Geräte zur Messung der Pufferhöhe über Schienenoberkante Kalibrierung — Länge Interne Verfahrensanweisung; Vergleichsverfahren; am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren Am festen Standort (S) Internes Verfahren PP-LMM-20","technique_de":"Interne Verfahrensanweisung; Vergleichsverfahren; am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren","Am festen Standort (S)"],"test_object_de":"Geräte zur Messung der Pufferhöhe über Schienenoberkante","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"900 mm to 1150 mm","cmc":"0,40 mm"}],"reference_zh":"内部程序 PP-LMM-20","regulatory_area_zh":"长度","search_zh":"缓冲器轴线距轨头高度测量仪 校准 — 长度 内部程序；比较法；在固定地点 (S) 长度 内部程序 比较法 在固定地点 (S) 内部程序 PP-LMM-20","technique_zh":"内部程序；比较法；在固定地点 (S)","techniques_zh":["内部程序","比较法","在固定地点 (S)"],"test_object_zh":"缓冲器轴线距轨头高度测量仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"900 mm to 1150 mm","cmc":"0,40 mm"}],"reference_cs":"Vnitřní postup PP-LMM-20","regulatory_area_cs":"Délka","search_cs":"Přístroje pro měření výšky osy nárazníku nad hlavou kolejnice Kalibrace — Délka Vnitřní postup; Srovnávací metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-20","technique_cs":"Vnitřní postup; Srovnávací metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Přístroje pro měření výšky osy nárazníku nad hlavou kolejnice"},{"_id":"82d8464f44caee17503b6871","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Suwmiarki","test_object_en":"Vernier calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm do 625 mm","cmc":"0,02 mm"},{"name":"","range":"0 mm do 1000 mm","cmc":"0,03 mm"}],"parameters_en":[{"name":"","range":"0 mm to 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm do 625 mm","cmc":"0,02 mm"},{"name":"","range":"0 mm to 1000 mm","cmc":"0,03 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 200 mm CMC 0,01 mm\n0 mm do 625 mm CMC 0,02 mm\n0 mm do 1000 mm CMC 0,03 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-06","norm_bases":["PP-LMM-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Suwmiarki Wzorcowanie — Długość\nZakres:\n0 mm do 200 mm CMC 0,01 mm\n0 mm do 625 mm CMC 0,02 mm\n0 mm do 1000 mm CMC 0,03 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-06 Suwmiarki Wzorcowanie — Dlugosc\nZakres:\n0 mm do 200 mm CMC 0,01 mm\n0 mm do 625 mm CMC 0,02 mm\n0 mm do 1000 mm CMC 0,03 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-06","search_en":"Vernier calipers Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) Internal procedure PP-LMM-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-06","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm do 625 mm","cmc":"0,02 mm"},{"name":"","range":"0 mm bis 1000 mm","cmc":"0,03 mm"}],"reference_de":"Internes Verfahren PP-LMM-06","regulatory_area_de":"Länge","search_de":"Messschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) Internes Verfahren PP-LMM-06","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Messschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm do 625 mm","cmc":"0,02 mm"},{"name":"","range":"0 mm 至 1000 mm","cmc":"0,03 mm"}],"reference_zh":"内部程序 PP-LMM-06","regulatory_area_zh":"长度","search_zh":"游标卡尺 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) 内部程序 PP-LMM-06","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm do 625 mm","cmc":"0,02 mm"},{"name":"","range":"0 mm do 1000 mm","cmc":"0,03 mm"}],"reference_cs":"Vnitřní postup PP-LMM-06","regulatory_area_cs":"Délka","search_cs":"Posuvná měřidla Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-06","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Posuvná měřidla"},{"_id":"b5169da05188a4536eb95982","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Przyrządy suwmiarkowe specjalne","test_object_en":"Special vernier instruments","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- wysokość obrzeża Ow","range":"0 mm do 45 mm","cmc":"0,07 mm"},{"name":"- szerokość obrzeża Og","range":"0 mm do 45 mm","cmc":"0,07 mm"},{"name":"- stromość obrzeża qR","range":"0 mm do 25 mm","cmc":"0,13 mm"}],"parameters_en":[{"name":"- flange height Ow","range":"0 mm to 45 mm","cmc":"0,07 mm"},{"name":"- flange width Og","range":"0 mm to 45 mm","cmc":"0,07 mm"},{"name":"- flange steepness qR","range":"0 mm to 25 mm","cmc":"0,13 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- wysokość obrzeża Ow 0 mm do 45 mm CMC 0,07 mm\n- szerokość obrzeża Og 0 mm do 45 mm CMC 0,07 mm\n- stromość obrzeża qR 0 mm do 25 mm CMC 0,13 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-17","norm_bases":["PP-LMM-17"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przyrządy suwmiarkowe specjalne Wzorcowanie — Długość\nZakres:\n- wysokość obrzeża Ow 0 mm do 45 mm CMC 0,07 mm\n- szerokość obrzeża Og 0 mm do 45 mm CMC 0,07 mm\n- stromość obrzeża qR 0 mm do 25 mm CMC 0,13 mm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-17 Przyrzady suwmiarkowe specjalne Wzorcowanie — Dlugosc\nZakres:\n- wysokosc obrzeza Ow 0 mm do 45 mm CMC 0,07 mm\n- szerokosc obrzeza Og 0 mm do 45 mm CMC 0,07 mm\n- stromosc obrzeza qR 0 mm do 25 mm CMC 0,13 mm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-17","search_en":"Special vernier instruments Calibration — Length Internal procedure; Direct method; At permanent location (S) Length Internal procedure Direct method At permanent location (S) - flange height Ow - flange width Og - flange steepness qR Internal procedure PP-LMM-17","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-17","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Spurkranzhöhe Ow","range":"0 mm to 45 mm","cmc":"0,07 mm"},{"name":"- Spurkranzdicke Og","range":"0 mm to 45 mm","cmc":"0,07 mm"},{"name":"- Spurkranzsteilheit qR","range":"0 mm bis 25 mm","cmc":"0,13 mm"}],"reference_de":"Internes Verfahren PP-LMM-17","regulatory_area_de":"Länge","search_de":"Spezialmessschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren Am festen Standort (S) - Spurkranzhöhe Ow - Spurkranzdicke Og - Spurkranzsteilheit qR Internes Verfahren PP-LMM-17","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Spezialmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 轮缘高度 Ow","range":"0 mm to 45 mm","cmc":"0,07 mm"},{"name":"- 轮缘厚度 Og","range":"0 mm to 45 mm","cmc":"0,07 mm"},{"name":"- 轮缘陡度 qR","range":"0 mm 至 25 mm","cmc":"0,13 mm"}],"reference_zh":"内部程序 PP-LMM-17","regulatory_area_zh":"长度","search_zh":"专用游标量具 校准 — 长度 内部程序；直接法；在固定地点 (S) 长度 内部程序 直接法 在固定地点 (S) - 轮缘高度 Ow - 轮缘厚度 Og - 轮缘陡度 qR 内部程序 PP-LMM-17","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"专用游标量具","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- výška okolku Ow","range":"0 mm to 45 mm","cmc":"0,07 mm"},{"name":"- šířka okolku Og","range":"0 mm to 45 mm","cmc":"0,07 mm"},{"name":"- strmost okolku qR","range":"0 mm do 25 mm","cmc":"0,13 mm"}],"reference_cs":"Vnitřní postup PP-LMM-17","regulatory_area_cs":"Délka","search_cs":"Speciální posuvná měřidla Kalibrace — Délka Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda Ve stálé lokalitě (S) - výška okolku Ow - šířka okolku Og - strmost okolku qR Vnitřní postup PP-LMM-17","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Speciální posuvná měřidla"},{"_id":"04bf5668ca35b8fdfa830205","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Szczelinomierze","test_object_en":"Feeler gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,03 mm do 2 mm","cmc":"0,6 µm"}],"parameters_en":[{"name":"","range":"0,03 mm to 2 mm","cmc":"0,6 µm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparison method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparison method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,03 mm do 2 mm CMC 0,6 µm\nProcedura wewnętrzna; Metoda porównawcza; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-14","norm_bases":["PP-LMM-14"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Szczelinomierze Wzorcowanie — Długość\n0,03 mm do 2 mm CMC 0,6 µm\nProcedura wewnętrzna; Metoda porównawcza; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-14 Szczelinomierze Wzorcowanie — Dlugosc\n0,03 mm do 2 mm CMC 0,6 µm\nProcedura wewnetrzna; Metoda porownawcza; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-14","search_en":"Feeler gauges Calibration — Length Internal procedure; Comparison method; At permanent location (S) Length Internal procedure Comparison method At permanent location (S) Internal procedure PP-LMM-14","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-14","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,03 mm to 2 mm","cmc":"0,6 µm"}],"reference_de":"Internes Verfahren PP-LMM-14","regulatory_area_de":"Länge","search_de":"Fühlerlehren Kalibrierung — Länge Interne Verfahrensanweisung; Vergleichsverfahren; am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren Am festen Standort (S) Internes Verfahren PP-LMM-14","technique_de":"Interne Verfahrensanweisung; Vergleichsverfahren; am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren","Am festen Standort (S)"],"test_object_de":"Fühlerlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,03 mm to 2 mm","cmc":"0,6 µm"}],"reference_zh":"内部程序 PP-LMM-14","regulatory_area_zh":"长度","search_zh":"塞尺 校准 — 长度 内部程序；比较法；在固定地点 (S) 长度 内部程序 比较法 在固定地点 (S) 内部程序 PP-LMM-14","technique_zh":"内部程序；比较法；在固定地点 (S)","techniques_zh":["内部程序","比较法","在固定地点 (S)"],"test_object_zh":"塞尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,03 mm to 2 mm","cmc":"0,6 µm"}],"reference_cs":"Vnitřní postup PP-LMM-14","regulatory_area_cs":"Délka","search_cs":"Spároměry Kalibrace — Délka Vnitřní postup; Srovnávací metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda Ve stálé lokalitě (S) Vnitřní postup PP-LMM-14","technique_cs":"Vnitřní postup; Srovnávací metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Spároměry"},{"_id":"d320df41e1a19ce1b6c21098","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Toromierze","test_object_en":"Track gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- szerokość toru","range":"1415 mm do 1470 mm","cmc":"0,20 mm"},{"name":"- przechyłka toru","range":"-140 mm do 140 mm","cmc":"0,50 mm"}],"parameters_en":[{"name":"- track gauge","range":"1415 mm to 1470 mm","cmc":"0,20 mm"},{"name":"- track cant","range":"-140 mm to 140 mm","cmc":"0,50 mm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparison method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparison method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- szerokość toru 1415 mm do 1470 mm CMC 0,20 mm\n- przechyłka toru -140 mm do 140 mm CMC 0,50 mm\nProcedura wewnętrzna; Metoda porównawcza; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-23","norm_bases":["PP-LMM-23"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Toromierze Wzorcowanie — Długość\nZakres:\n- szerokość toru 1415 mm do 1470 mm CMC 0,20 mm\n- przechyłka toru -140 mm do 140 mm CMC 0,50 mm\nProcedura wewnętrzna; Metoda porównawcza; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-23 Toromierze Wzorcowanie — Dlugosc\nZakres:\n- szerokosc toru 1415 mm do 1470 mm CMC 0,20 mm\n- przechylka toru -140 mm do 140 mm CMC 0,50 mm\nProcedura wewnetrzna; Metoda porownawcza; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-23","search_en":"Track gauges Calibration — Length Internal procedure; Comparison method; At permanent location (S) Length Internal procedure Comparison method At permanent location (S) - track gauge - track cant Internal procedure PP-LMM-23","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-23","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Spurweite","range":"1415 mm to 1470 mm","cmc":"0,20 mm"},{"name":"- Gleisüberhöhung","range":"-140 mm to 140 mm","cmc":"0,50 mm"}],"reference_de":"Internes Verfahren PP-LMM-23","regulatory_area_de":"Länge","search_de":"Spurweitenmessgeräte Kalibrierung — Länge Interne Verfahrensanweisung; Vergleichsverfahren; am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren Am festen Standort (S) - Spurweite - Gleisüberhöhung Internes Verfahren PP-LMM-23","technique_de":"Interne Verfahrensanweisung; Vergleichsverfahren; am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren","Am festen Standort (S)"],"test_object_de":"Spurweitenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 轨距","range":"1415 mm to 1470 mm","cmc":"0,20 mm"},{"name":"- 轨道超高","range":"-140 mm to 140 mm","cmc":"0,50 mm"}],"reference_zh":"内部程序 PP-LMM-23","regulatory_area_zh":"长度","search_zh":"轨距尺 校准 — 长度 内部程序；比较法；在固定地点 (S) 长度 内部程序 比较法 在固定地点 (S) - 轨距 - 轨道超高 内部程序 PP-LMM-23","technique_zh":"内部程序；比较法；在固定地点 (S)","techniques_zh":["内部程序","比较法","在固定地点 (S)"],"test_object_zh":"轨距尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- rozchod koleje","range":"1415 mm to 1470 mm","cmc":"0,20 mm"},{"name":"- převýšení koleje","range":"-140 mm to 140 mm","cmc":"0,50 mm"}],"reference_cs":"Vnitřní postup PP-LMM-23","regulatory_area_cs":"Délka","search_cs":"Rozchodky Kalibrace — Délka Vnitřní postup; Srovnávací metoda; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda Ve stálé lokalitě (S) - rozchod koleje - převýšení koleje Vnitřní postup PP-LMM-23","technique_cs":"Vnitřní postup; Srovnávací metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Rozchodky"},{"_id":"4135142288ed2c55b9a10c1c","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Transametry","test_object_en":"Indicating snap gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"25 mm do 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"2,9 µm"}],"parameters_en":[{"name":"","range":"25 mm to 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"2,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n25 mm do 50 mm CMC 1,6 µm\n50 mm do 100 mm CMC 2,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-12","norm_bases":["PP-LMM-12"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Transametry Wzorcowanie — Długość\nZakres:\n25 mm do 50 mm CMC 1,6 µm\n50 mm do 100 mm CMC 2,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-12 Transametry Wzorcowanie — Dlugosc\nZakres:\n25 mm do 50 mm CMC 1,6 µm\n50 mm do 100 mm CMC 2,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-12","search_en":"Indicating snap gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure PP-LMM-12","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":19,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-12","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"25 mm bis 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"2,9 µm"}],"reference_de":"Internes Verfahren PP-LMM-12","regulatory_area_de":"Länge","search_de":"Transameter Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren PP-LMM-12","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Transameter","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"25 mm 至 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"2,9 µm"}],"reference_zh":"内部程序 PP-LMM-12","regulatory_area_zh":"长度","search_zh":"Transametr 量仪 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 PP-LMM-12","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"Transametr 量仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"25 mm do 50 mm","cmc":"1,6 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"2,9 µm"}],"reference_cs":"Vnitřní postup PP-LMM-12","regulatory_area_cs":"Délka","search_cs":"Pasametry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup PP-LMM-12","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Pasametry"},{"_id":"8f79064b1dd49f0782643ee9","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Wysokościomierze suwmiarkowe","test_object_en":"Vernier height gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm do 600 mm","cmc":"0,02 mm"}],"parameters_en":[{"name":"","range":"0 mm to 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm to 600 mm","cmc":"0,02 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 200 mm CMC 0,01 mm\n0 mm do 600 mm CMC 0,02 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-07","norm_bases":["PP-LMM-07"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wysokościomierze suwmiarkowe Wzorcowanie — Długość\nZakres:\n0 mm do 200 mm CMC 0,01 mm\n0 mm do 600 mm CMC 0,02 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-07 Wysokosciomierze suwmiarkowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 200 mm CMC 0,01 mm\n0 mm do 600 mm CMC 0,02 mm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-07","search_en":"Vernier height gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure PP-LMM-07","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":20,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-07","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm bis 600 mm","cmc":"0,02 mm"}],"reference_de":"Internes Verfahren PP-LMM-07","regulatory_area_de":"Länge","search_de":"Höhenmessschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren PP-LMM-07","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Höhenmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm 至 600 mm","cmc":"0,02 mm"}],"reference_zh":"内部程序 PP-LMM-07","regulatory_area_zh":"长度","search_zh":"游标高度尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 PP-LMM-07","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"游标高度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 200 mm","cmc":"0,01 mm"},{"name":"","range":"0 mm do 600 mm","cmc":"0,02 mm"}],"reference_cs":"Vnitřní postup PP-LMM-07","regulatory_area_cs":"Délka","search_cs":"Posuvné výškoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup PP-LMM-07","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Posuvné výškoměry"},{"_id":"038107f8a4d199beba2fbebe","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Wzorce nastawcze do wymiarów zewnętrznych","test_object_en":"Setting standards for external dimensions","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 100 mm","cmc":"2,6 µm"},{"name":"","range":"100 mm do 250 mm","cmc":"2,7 µm"},{"name":"","range":"250 mm do 500 mm","cmc":"4,2 µm"},{"name":"","range":"500 mm do 650 mm","cmc":"5,2 µm"},{"name":"","range":"650 mm do 800 mm","cmc":"6,1 µm"},{"name":"","range":"800 mm do 1000 mm","cmc":"7,5 µm"},{"name":"","range":"1000 mm do 1350 mm","cmc":"9,8 µm"},{"name":"","range":"1350 mm do 1550 mm","cmc":"11,1 µm"},{"name":"","range":"1550 mm do 1750 mm","cmc":"12,5 µm"},{"name":"","range":"1750 mm do 2000 mm","cmc":"14,2 µm"},{"name":"","range":"2000 mm do 2500 mm","cmc":"17,5 µm"},{"name":"","range":"2500 mm do 3000 mm","cmc":"20,9 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"2,6 µm"},{"name":"","range":"100 mm to 250 mm","cmc":"2,7 µm"},{"name":"","range":"250 mm to 500 mm","cmc":"4,2 µm"},{"name":"","range":"500 mm to 650 mm","cmc":"5,2 µm"},{"name":"","range":"650 mm to 800 mm","cmc":"6,1 µm"},{"name":"","range":"800 mm to 1000 mm","cmc":"7,5 µm"},{"name":"","range":"1000 mm to 1350 mm","cmc":"9,8 µm"},{"name":"","range":"1350 mm to 1550 mm","cmc":"11,1 µm"},{"name":"","range":"1550 mm to 1750 mm","cmc":"12,5 µm"},{"name":"","range":"1750 mm to 2000 mm","cmc":"14,2 µm"},{"name":"","range":"2000 mm to 2500 mm","cmc":"17,5 µm"},{"name":"","range":"2500 mm to 3000 mm","cmc":"20,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem maszyny długościowej; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem maszyny długościowej","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 100 mm CMC 2,6 µm\n100 mm do 250 mm CMC 2,7 µm\n250 mm do 500 mm CMC 4,2 µm\n500 mm do 650 mm CMC 5,2 µm\n650 mm do 800 mm CMC 6,1 µm\n800 mm do 1000 mm CMC 7,5 µm\n1000 mm do 1350 mm CMC 9,8 µm\n1350 mm do 1550 mm CMC 11,1 µm\n1550 mm do 1750 mm CMC 12,5 µm\n1750 mm do 2000 mm CMC 14,2 µm\n2000 mm do 2500 mm CMC 17,5 µm\n2500 mm do 3000 mm CMC 20,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem maszyny długościowej; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-03","norm_bases":["PP-LMM-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce nastawcze do wymiarów zewnętrznych Wzorcowanie — Długość\nZakres:\n0 mm do 100 mm CMC 2,6 µm\n100 mm do 250 mm CMC 2,7 µm\n250 mm do 500 mm CMC 4,2 µm\n500 mm do 650 mm CMC 5,2 µm\n650 mm do 800 mm CMC 6,1 µm\n800 mm do 1000 mm CMC 7,5 µm\n1000 mm do 1350 mm CMC 9,8 µm\n1350 mm do 1550 mm CMC 11,1 µm\n1550 mm do 1750 mm CMC 12,5 µm\n1750 mm do 2000 mm CMC 14,2 µm\n2000 mm do 2500 mm CMC 17,5 µm\n2500 mm do 3000 mm CMC 20,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem maszyny długościowej; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-03 Wzorce nastawcze do wymiarow zewnetrznych Wzorcowanie — Dlugosc\nZakres:\n0 mm do 100 mm CMC 2,6 µm\n100 mm do 250 mm CMC 2,7 µm\n250 mm do 500 mm CMC 4,2 µm\n500 mm do 650 mm CMC 5,2 µm\n650 mm do 800 mm CMC 6,1 µm\n800 mm do 1000 mm CMC 7,5 µm\n1000 mm do 1350 mm CMC 9,8 µm\n1350 mm do 1550 mm CMC 11,1 µm\n1550 mm do 1750 mm CMC 12,5 µm\n1750 mm do 2000 mm CMC 14,2 µm\n2000 mm do 2500 mm CMC 17,5 µm\n2500 mm do 3000 mm CMC 20,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem maszyny dlugosciowej; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-03","search_en":"Setting standards for external dimensions Calibration — Length Internal procedure; Direct method using a length measuring machine; At permanent location (S) Length Internal procedure Direct method using a length measuring machine At permanent location (S) Internal procedure PP-LMM-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":21,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 100 mm","cmc":"2,6 µm"},{"name":"","range":"100 mm to 250 mm","cmc":"2,7 µm"},{"name":"","range":"250 mm to 500 mm","cmc":"4,2 µm"},{"name":"","range":"500 mm to 650 mm","cmc":"5,2 µm"},{"name":"","range":"650 mm to 800 mm","cmc":"6,1 µm"},{"name":"","range":"800 mm to 1000 mm","cmc":"7,5 µm"},{"name":"","range":"1000 mm to 1350 mm","cmc":"9,8 µm"},{"name":"","range":"1350 mm to 1550 mm","cmc":"11,1 µm"},{"name":"","range":"1550 mm to 1750 mm","cmc":"12,5 µm"},{"name":"","range":"1750 mm to 2000 mm","cmc":"14,2 µm"},{"name":"","range":"2000 mm to 2500 mm","cmc":"17,5 µm"},{"name":"","range":"2500 mm to 3000 mm","cmc":"20,9 µm"}],"reference_de":"Internes Verfahren PP-LMM-03","regulatory_area_de":"Länge","search_de":"Einstellnormale für Außenmaße Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einer Längenmessmaschine; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einer Längenmessmaschine Am festen Standort (S) Internes Verfahren PP-LMM-03","technique_de":"Internes Verfahren; Direktes Verfahren mit einer Längenmessmaschine; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einer Längenmessmaschine","Am festen Standort (S)"],"test_object_de":"Einstellnormale für Außenmaße","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 100 mm","cmc":"2,6 µm"},{"name":"","range":"100 mm to 250 mm","cmc":"2,7 µm"},{"name":"","range":"250 mm to 500 mm","cmc":"4,2 µm"},{"name":"","range":"500 mm to 650 mm","cmc":"5,2 µm"},{"name":"","range":"650 mm to 800 mm","cmc":"6,1 µm"},{"name":"","range":"800 mm to 1000 mm","cmc":"7,5 µm"},{"name":"","range":"1000 mm to 1350 mm","cmc":"9,8 µm"},{"name":"","range":"1350 mm to 1550 mm","cmc":"11,1 µm"},{"name":"","range":"1550 mm to 1750 mm","cmc":"12,5 µm"},{"name":"","range":"1750 mm to 2000 mm","cmc":"14,2 µm"},{"name":"","range":"2000 mm to 2500 mm","cmc":"17,5 µm"},{"name":"","range":"2500 mm to 3000 mm","cmc":"20,9 µm"}],"reference_zh":"内部程序 PP-LMM-03","regulatory_area_zh":"长度","search_zh":"外尺寸校对规 校准 — 长度 内部程序；使用测长机的直接法；在固定地点 (S) 长度 内部程序 使用测长机的直接法 在固定地点 (S) 内部程序 PP-LMM-03","technique_zh":"内部程序；使用测长机的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用测长机的直接法","在固定地点 (S)"],"test_object_zh":"外尺寸校对规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 100 mm","cmc":"2,6 µm"},{"name":"","range":"100 mm to 250 mm","cmc":"2,7 µm"},{"name":"","range":"250 mm to 500 mm","cmc":"4,2 µm"},{"name":"","range":"500 mm to 650 mm","cmc":"5,2 µm"},{"name":"","range":"650 mm to 800 mm","cmc":"6,1 µm"},{"name":"","range":"800 mm to 1000 mm","cmc":"7,5 µm"},{"name":"","range":"1000 mm to 1350 mm","cmc":"9,8 µm"},{"name":"","range":"1350 mm to 1550 mm","cmc":"11,1 µm"},{"name":"","range":"1550 mm to 1750 mm","cmc":"12,5 µm"},{"name":"","range":"1750 mm to 2000 mm","cmc":"14,2 µm"},{"name":"","range":"2000 mm to 2500 mm","cmc":"17,5 µm"},{"name":"","range":"2500 mm to 3000 mm","cmc":"20,9 µm"}],"reference_cs":"Vnitřní postup PP-LMM-03","regulatory_area_cs":"Délka","search_cs":"Nastavovací etalony pro vnější rozměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkového měřicího stroje; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkového měřicího stroje Ve stálé lokalitě (S) Vnitřní postup PP-LMM-03","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkového měřicího stroje; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkového měřicího stroje","Ve stálé lokalitě (S)"],"test_object_cs":"Nastavovací etalony pro vnější rozměry"},{"_id":"50950e83258a4b40ab6c82fb","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Płaskie płytki interferencyjne","test_object_en":"Optical flats","methodology":"Wzorcowanie — Długość (geometria powierzchni)","methodology_en":"Calibration — Length (surface geometry)","parameters":[{"name":"średnica","range":"0 mm do 100 mm","cmc":"0,04 µm"}],"parameters_en":[{"name":"diameter","range":"0 mm to 100 mm","cmc":"0,04 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem płytek interferencyjnych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using optical flats; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem płytek interferencyjnych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using optical flats","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (geometria powierzchni)\nśrednica 0 mm do 100 mm CMC 0,04 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem płytek interferencyjnych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LMM-05","norm_bases":["PP-LMM-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (geometria powierzchni)","regulatory_area_en":"Length (surface geometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Płaskie płytki interferencyjne Wzorcowanie — Długość (geometria powierzchni)\nśrednica 0 mm do 100 mm CMC 0,04 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem płytek interferencyjnych; W stałej lokalizacji (S) Procedura wewnętrzna PP-LMM-05 Plaskie plytki interferencyjne Wzorcowanie — Dlugosc (geometria powierzchni)\nsrednica 0 mm do 100 mm CMC 0,04 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem plytek interferencyjnych; W stalej lokalizacji (S) Procedura wewnetrzna PP-LMM-05","search_en":"Optical flats Calibration — Length (surface geometry) Internal procedure; Indirect method using optical flats; At permanent location (S) Length (surface geometry) Internal procedure Indirect method using optical flats At permanent location (S) diameter Internal procedure PP-LMM-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":22,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LMM-05","methodology_de":"Kalibrierung — Länge (Oberflächengeometrie)","parameters_de":[{"name":"Durchmesser","range":"0 mm to 100 mm","cmc":"0,04 µm"}],"reference_de":"Internes Verfahren PP-LMM-05","regulatory_area_de":"Länge (Oberflächengeometrie)","search_de":"Planglasplatten Kalibrierung — Länge (Oberflächengeometrie) Internes Verfahren; Indirektes Verfahren mit Planglasplatten; Am festen Standort (S) Länge (Oberflächengeometrie) Internes Verfahren Indirektes Verfahren mit Planglasplatten Am festen Standort (S) Durchmesser Internes Verfahren PP-LMM-05","technique_de":"Internes Verfahren; Indirektes Verfahren mit Planglasplatten; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit Planglasplatten","Am festen Standort (S)"],"test_object_de":"Planglasplatten","methodology_zh":"校准 — 长度（表面几何）","parameters_zh":[{"name":"直径","range":"0 mm to 100 mm","cmc":"0,04 µm"}],"reference_zh":"内部程序 PP-LMM-05","regulatory_area_zh":"长度（表面几何）","search_zh":"平面平晶 校准 — 长度（表面几何） 内部程序；使用平晶的间接法；在固定地点 (S) 长度（表面几何） 内部程序 使用平晶的间接法 在固定地点 (S) 直径 内部程序 PP-LMM-05","technique_zh":"内部程序；使用平晶的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用平晶的间接法","在固定地点 (S)"],"test_object_zh":"平面平晶","methodology_cs":"Kalibrace — Délka (geometrie povrchu)","parameters_cs":[{"name":"průměr","range":"0 mm to 100 mm","cmc":"0,04 µm"}],"reference_cs":"Vnitřní postup PP-LMM-05","regulatory_area_cs":"Délka (geometrie povrchu)","search_cs":"Rovinné interferenční destičky Kalibrace — Délka (geometrie povrchu) Vnitřní postup; Nepřímá metoda s použitím interferenčních destiček; Ve stálé lokalitě (S) Délka (geometrie povrchu) Vnitřní postup Nepřímá metoda s použitím interferenčních destiček Ve stálé lokalitě (S) průměr Vnitřní postup PP-LMM-05","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím interferenčních destiček; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím interferenčních destiček","Ve stálé lokalitě (S)"],"test_object_cs":"Rovinné interferenční destičky"},{"_id":"c0554662ed09ffcedb002af9","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Kalibratory\nZasilacze","test_object_en":"Calibrators\nPower supplies","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"100 µV do 100 mV","cmc":"0,0011 % + 1 µV"},{"name":"","range":"100 mV do 1 V","cmc":"0,0015 % + 2,5 µV"},{"name":"","range":"1 V do 10 V","cmc":"0,0015 % + 15 µV"},{"name":"","range":"10 V do 100 V","cmc":"0,004 % + 0,6 mV"},{"name":"","range":"100 V do 1000 V","cmc":"0,004 % + 6 mV"}],"parameters_en":[{"name":"","range":"100 µV to 100 mV","cmc":"0,0011 % + 1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"0,0015 % + 2,5 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,0015 % + 15 µV"},{"name":"","range":"10 V to 100 V","cmc":"0,004 % + 0,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"0,004 % + 6 mV"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n100 µV do 100 mV CMC 0,0011 % + 1 µV\n100 mV do 1 V CMC 0,0015 % + 2,5 µV\n1 V do 10 V CMC 0,0015 % + 15 µV\n10 V do 100 V CMC 0,004 % + 0,6 mV\n100 V do 1000 V CMC 0,004 % + 6 mV\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LME-04","norm_bases":["PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kalibratory\nZasilacze Wzorcowanie — Napięcie DC\nZakres:\n100 µV do 100 mV CMC 0,0011 % + 1 µV\n100 mV do 1 V CMC 0,0015 % + 2,5 µV\n1 V do 10 V CMC 0,0015 % + 15 µV\n10 V do 100 V CMC 0,004 % + 0,6 mV\n100 V do 1000 V CMC 0,004 % + 6 mV\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP-LME-04 Kalibratory\nZasilacze Wzorcowanie — Napiecie DC\nZakres:\n100 µV do 100 mV CMC 0,0011 % + 1 µV\n100 mV do 1 V CMC 0,0015 % + 2,5 µV\n1 V do 10 V CMC 0,0015 % + 15 µV\n10 V do 100 V CMC 0,004 % + 0,6 mV\n100 V do 1000 V CMC 0,004 % + 6 mV\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP-LME-04","search_en":"Calibrators Power supplies Calibration — DC voltage Internal procedure; At permanent location (S) DC voltage Internal procedure At permanent location (S) Internal procedure PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":23,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LME-04","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"100 µV to 100 mV","cmc":"0,0011 % + 1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"0,0015 % + 2,5 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,0015 % + 15 µV"},{"name":"","range":"10 V to 100 V","cmc":"0,004 % + 0,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"0,004 % + 6 mV"}],"reference_de":"Internes Verfahren PP-LME-04","regulatory_area_de":"DC-Spannung","search_de":"Kalibratoren Netzgeräte Kalibrierung — DC-Spannung Internes Verfahren; Am festen Standort (S) DC-Spannung Internes Verfahren Am festen Standort (S) Internes Verfahren PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"100 µV to 100 mV","cmc":"0,0011 % + 1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"0,0015 % + 2,5 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,0015 % + 15 µV"},{"name":"","range":"10 V to 100 V","cmc":"0,004 % + 0,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"0,004 % + 6 mV"}],"reference_zh":"内部程序 PP-LME-04","regulatory_area_zh":"直流电压","search_zh":"校准器 电源 校准 — 直流电压 内部程序；在固定地点 (S) 直流电压 内部程序 在固定地点 (S) 内部程序 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器\n电源","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"100 µV to 100 mV","cmc":"0,0011 % + 1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"0,0015 % + 2,5 µV"},{"name":"","range":"1 V to 10 V","cmc":"0,0015 % + 15 µV"},{"name":"","range":"10 V to 100 V","cmc":"0,004 % + 0,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"0,004 % + 6 mV"}],"reference_cs":"Vnitřní postup PP-LME-04","regulatory_area_cs":"Napětí DC","search_cs":"Kalibrátory Napájecí zdroje Kalibrace — Napětí DC Vnitřní postup; Ve stálé lokalitě (S) Napětí DC Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nNapájecí zdroje"},{"_id":"9784ecf34cb6243c6da13f22","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Multimetry\nMierniki napięcia analogowe i cyfrowe\nSondy napięciowe","test_object_en":"Multimeters\nAnalogue and digital voltmeters\nVoltage probes","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0 µV","cmc":"0,5 µV"},{"name":"","range":"100 µV do 220 mV","cmc":"0,0009 % + 0,5 µV"},{"name":"","range":"220 mV do 2,2 V","cmc":"0,0008 %"},{"name":"","range":"2,2 V do 22 V","cmc":"0,0005 %"},{"name":"","range":"22 V do 220 V","cmc":"0,0007 %"},{"name":"","range":"220 V do 1100 V","cmc":"0,0008 %"}],"parameters_en":[{"name":"","range":"0 µV","cmc":"0,5 µV"},{"name":"","range":"100 µV to 220 mV","cmc":"0,0009 % + 0,5 µV"},{"name":"","range":"220 mV to 2,2 V","cmc":"0,0008 %"},{"name":"","range":"2,2 V to 22 V","cmc":"0,0005 %"},{"name":"","range":"22 V to 220 V","cmc":"0,0007 %"},{"name":"","range":"220 V to 1100 V","cmc":"0,0008 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0 µV CMC 0,5 µV\n100 µV do 220 mV CMC 0,0009 % + 0,5 µV\n220 mV do 2,2 V CMC 0,0008 %\n2,2 V do 22 V CMC 0,0005 %\n22 V do 220 V CMC 0,0007 %\n220 V do 1100 V CMC 0,0008 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedury wewnętrzne PP-LME-03 PP-LME-04","norm_bases":["PP-LME-03","PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Multimetry\nMierniki napięcia analogowe i cyfrowe\nSondy napięciowe Wzorcowanie — Napięcie DC\nZakres:\n0 µV CMC 0,5 µV\n100 µV do 220 mV CMC 0,0009 % + 0,5 µV\n220 mV do 2,2 V CMC 0,0008 %\n2,2 V do 22 V CMC 0,0005 %\n22 V do 220 V CMC 0,0007 %\n220 V do 1100 V CMC 0,0008 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedury wewnętrzne PP-LME-03 PP-LME-04 Multimetry\nMierniki napiecia analogowe i cyfrowe\nSondy napieciowe Wzorcowanie — Napiecie DC\nZakres:\n0 µV CMC 0,5 µV\n100 µV do 220 mV CMC 0,0009 % + 0,5 µV\n220 mV do 2,2 V CMC 0,0008 %\n2,2 V do 22 V CMC 0,0005 %\n22 V do 220 V CMC 0,0007 %\n220 V do 1100 V CMC 0,0008 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedury wewnetrzne PP-LME-03 PP-LME-04","search_en":"Multimeters Analogue and digital voltmeters Voltage probes Calibration — DC voltage Internal procedure; At permanent location (S) DC voltage Internal procedure At permanent location (S) Internal procedures PP-LME-03 PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":24,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedures PP-LME-03 PP-LME-04","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0 µV","cmc":"0,5 µV"},{"name":"","range":"100 µV to 220 mV","cmc":"0,0009 % + 0,5 µV"},{"name":"","range":"220 mV to 2,2 V","cmc":"0,0008 %"},{"name":"","range":"2,2 V to 22 V","cmc":"0,0005 %"},{"name":"","range":"22 V to 220 V","cmc":"0,0007 %"},{"name":"","range":"220 V to 1100 V","cmc":"0,0008 %"}],"reference_de":"Interne Verfahren PP-LME-03 PP-LME-04","regulatory_area_de":"DC-Spannung","search_de":"Multimeter Analoge und digitale Spannungsmessgeräte Spannungstastköpfe Kalibrierung — DC-Spannung Internes Verfahren; Am festen Standort (S) DC-Spannung Internes Verfahren Am festen Standort (S) Interne Verfahren PP-LME-03 PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter\nAnaloge und digitale Spannungsmessgeräte\nSpannungstastköpfe","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0 µV","cmc":"0,5 µV"},{"name":"","range":"100 µV to 220 mV","cmc":"0,0009 % + 0,5 µV"},{"name":"","range":"220 mV to 2,2 V","cmc":"0,0008 %"},{"name":"","range":"2,2 V to 22 V","cmc":"0,0005 %"},{"name":"","range":"22 V to 220 V","cmc":"0,0007 %"},{"name":"","range":"220 V to 1100 V","cmc":"0,0008 %"}],"reference_zh":"内部程序 PP-LME-03 PP-LME-04","regulatory_area_zh":"直流电压","search_zh":"万用表 模拟和数字电压表 电压探头 校准 — 直流电压 内部程序；在固定地点 (S) 直流电压 内部程序 在固定地点 (S) 内部程序 PP-LME-03 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"万用表\n模拟和数字电压表\n电压探头","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0 µV","cmc":"0,5 µV"},{"name":"","range":"100 µV to 220 mV","cmc":"0,0009 % + 0,5 µV"},{"name":"","range":"220 mV to 2,2 V","cmc":"0,0008 %"},{"name":"","range":"2,2 V to 22 V","cmc":"0,0005 %"},{"name":"","range":"22 V to 220 V","cmc":"0,0007 %"},{"name":"","range":"220 V to 1100 V","cmc":"0,0008 %"}],"reference_cs":"Interní postupy PP-LME-03 PP-LME-04","regulatory_area_cs":"Napětí DC","search_cs":"Multimetry Analogové a digitální měřiče napětí Napěťové sondy Kalibrace — Napětí DC Vnitřní postup; Ve stálé lokalitě (S) Napětí DC Vnitřní postup Ve stálé lokalitě (S) Interní postupy PP-LME-03 PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry\nAnalogové a digitální měřiče napětí\nNapěťové sondy"},{"_id":"5afa2c5da9529380458cc5bb","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Kalibratory\nZasilacze","test_object_en":"Calibrators\nPower supplies","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"1 µA do 10 µA","cmc":"0,005 % + 0,4 nA"},{"name":"","range":"10 µA do 100 µA","cmc":"0,006 % + 1,2 nA"},{"name":"","range":"100 µA do 1 mA","cmc":"0,006 % + 0,012 µA"},{"name":"","range":"1 mA do 10 mA","cmc":"0,006 % + 0,12 µA"},{"name":"","range":"10 mA do 100 mA","cmc":"0,013 % + 3,8 µA"},{"name":"","range":"100 mA do 1 A","cmc":"0,04 % + 0,064 mA"},{"name":"","range":"1 A do 3 A","cmc":"0,04 % + 0,21 mA"},{"name":"","range":"3 A do 10 A","cmc":"0,13 % + 4,5 mA"}],"parameters_en":[{"name":"","range":"1 µA to 10 µA","cmc":"0,005 % + 0,4 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"0,006 % + 1,2 nA"},{"name":"","range":"100 µA to 1 mA","cmc":"0,006 % + 0,012 µA"},{"name":"","range":"1 mA to 10 mA","cmc":"0,006 % + 0,12 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,013 % + 3,8 µA"},{"name":"","range":"100 mA to 1 A","cmc":"0,04 % + 0,064 mA"},{"name":"","range":"1 A to 3 A","cmc":"0,04 % + 0,21 mA"},{"name":"","range":"3 A to 10 A","cmc":"0,13 % + 4,5 mA"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n1 µA do 10 µA CMC 0,005 % + 0,4 nA\n10 µA do 100 µA CMC 0,006 % + 1,2 nA\n100 µA do 1 mA CMC 0,006 % + 0,012 µA\n1 mA do 10 mA CMC 0,006 % + 0,12 µA\n10 mA do 100 mA CMC 0,013 % + 3,8 µA\n100 mA do 1 A CMC 0,04 % + 0,064 mA\n1 A do 3 A CMC 0,04 % + 0,21 mA\n3 A do 10 A CMC 0,13 % + 4,5 mA\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LME-04","norm_bases":["PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kalibratory\nZasilacze Wzorcowanie — Prąd DC\nZakres:\n1 µA do 10 µA CMC 0,005 % + 0,4 nA\n10 µA do 100 µA CMC 0,006 % + 1,2 nA\n100 µA do 1 mA CMC 0,006 % + 0,012 µA\n1 mA do 10 mA CMC 0,006 % + 0,12 µA\n10 mA do 100 mA CMC 0,013 % + 3,8 µA\n100 mA do 1 A CMC 0,04 % + 0,064 mA\n1 A do 3 A CMC 0,04 % + 0,21 mA\n3 A do 10 A CMC 0,13 % + 4,5 mA\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP-LME-04 Kalibratory\nZasilacze Wzorcowanie — Prad DC\nZakres:\n1 µA do 10 µA CMC 0,005 % + 0,4 nA\n10 µA do 100 µA CMC 0,006 % + 1,2 nA\n100 µA do 1 mA CMC 0,006 % + 0,012 µA\n1 mA do 10 mA CMC 0,006 % + 0,12 µA\n10 mA do 100 mA CMC 0,013 % + 3,8 µA\n100 mA do 1 A CMC 0,04 % + 0,064 mA\n1 A do 3 A CMC 0,04 % + 0,21 mA\n3 A do 10 A CMC 0,13 % + 4,5 mA\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP-LME-04","search_en":"Calibrators Power supplies Calibration — DC current Internal procedure; At permanent location (S) DC current Internal procedure At permanent location (S) Internal procedure PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":25,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LME-04","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"1 µA to 10 µA","cmc":"0,005 % + 0,4 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"0,006 % + 1,2 nA"},{"name":"","range":"100 µA to 1 mA","cmc":"0,006 % + 0,012 µA"},{"name":"","range":"1 mA to 10 mA","cmc":"0,006 % + 0,12 µA"},{"name":"","range":"10 mA bis 100 mA","cmc":"0,013 % + 3,8 µA"},{"name":"","range":"100 mA to 1 A","cmc":"0,04 % + 0,064 mA"},{"name":"","range":"1 A to 3 A","cmc":"0,04 % + 0,21 mA"},{"name":"","range":"3 A to 10 A","cmc":"0,13 % + 4,5 mA"}],"reference_de":"Internes Verfahren PP-LME-04","regulatory_area_de":"DC-Strom","search_de":"Kalibratoren Netzgeräte Kalibrierung — DC-Strom Internes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Am festen Standort (S) Internes Verfahren PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"1 µA to 10 µA","cmc":"0,005 % + 0,4 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"0,006 % + 1,2 nA"},{"name":"","range":"100 µA to 1 mA","cmc":"0,006 % + 0,012 µA"},{"name":"","range":"1 mA to 10 mA","cmc":"0,006 % + 0,12 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,013 % + 3,8 µA"},{"name":"","range":"100 mA to 1 A","cmc":"0,04 % + 0,064 mA"},{"name":"","range":"1 A to 3 A","cmc":"0,04 % + 0,21 mA"},{"name":"","range":"3 A to 10 A","cmc":"0,13 % + 4,5 mA"}],"reference_zh":"内部程序 PP-LME-04","regulatory_area_zh":"直流电流","search_zh":"校准器 电源 校准 — 直流电流 内部程序；在固定地点 (S) 直流电流 内部程序 在固定地点 (S) 内部程序 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器\n电源","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"1 µA to 10 µA","cmc":"0,005 % + 0,4 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"0,006 % + 1,2 nA"},{"name":"","range":"100 µA to 1 mA","cmc":"0,006 % + 0,012 µA"},{"name":"","range":"1 mA to 10 mA","cmc":"0,006 % + 0,12 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,013 % + 3,8 µA"},{"name":"","range":"100 mA to 1 A","cmc":"0,04 % + 0,064 mA"},{"name":"","range":"1 A to 3 A","cmc":"0,04 % + 0,21 mA"},{"name":"","range":"3 A to 10 A","cmc":"0,13 % + 4,5 mA"}],"reference_cs":"Vnitřní postup PP-LME-04","regulatory_area_cs":"Proud DC","search_cs":"Kalibrátory Napájecí zdroje Kalibrace — Proud DC Vnitřní postup; Ve stálé lokalitě (S) Proud DC Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nNapájecí zdroje"},{"_id":"5263f845753c78d1622dc5bc","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0 µA","cmc":"6,9 nA"},{"name":"","range":"1 µA do 220 µA","cmc":"0,004 % + 6 nA"},{"name":"","range":"220 µA do 2,2 mA","cmc":"0,002 % + 0,06 µA"},{"name":"","range":"2,2 mA do 22 mA","cmc":"0,0034 % + 0,05 µA"},{"name":"","range":"22 mA do 220 mA","cmc":"0,0047 % + 0,7 µA"},{"name":"","range":"220 mA do 2,2 A","cmc":"0,008 % + 0,012 mA"},{"name":"","range":"2,2 A do 20 A","cmc":"0,012% + 0,002 A"},{"name":"","range":"20 A do 100 A","cmc":"0,7 % + 0,14 A"},{"name":"","range":"100 A do 2500 A","cmc":"0,7 % + 0,84 A"}],"parameters_en":[{"name":"","range":"0 µA","cmc":"6,9 nA"},{"name":"","range":"1 µA to 220 µA","cmc":"0,004 % + 6 nA"},{"name":"","range":"220 µA to 2,2 mA","cmc":"0,002 % + 0,06 µA"},{"name":"","range":"2,2 mA to 22 mA","cmc":"0,0034 % + 0,05 µA"},{"name":"","range":"22 mA to 220 mA","cmc":"0,0047 % + 0,7 µA"},{"name":"","range":"220 mA to 2,2 A","cmc":"0,008 % + 0,012 mA"},{"name":"","range":"2,2 A to 20 A","cmc":"0,012% + 0,002 A"},{"name":"","range":"20 A to 100 A","cmc":"0,7 % + 0,14 A"},{"name":"","range":"100 A to 2500 A","cmc":"0,7 % + 0,84 A"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0 µA CMC 6,9 nA\n1 µA do 220 µA CMC 0,004 % + 6 nA\n220 µA do 2,2 mA CMC 0,002 % + 0,06 µA\n2,2 mA do 22 mA CMC 0,0034 % + 0,05 µA\n22 mA do 220 mA CMC 0,0047 % + 0,7 µA\n220 mA do 2,2 A CMC 0,008 % + 0,012 mA\n2,2 A do 20 A CMC 0,012% + 0,002 A\n20 A do 100 A CMC 0,7 % + 0,14 A\n100 A do 2500 A CMC 0,7 % + 0,84 A\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LME-04","norm_bases":["PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki cęgowe Wzorcowanie — Prąd DC\nZakres:\n0 µA CMC 6,9 nA\n1 µA do 220 µA CMC 0,004 % + 6 nA\n220 µA do 2,2 mA CMC 0,002 % + 0,06 µA\n2,2 mA do 22 mA CMC 0,0034 % + 0,05 µA\n22 mA do 220 mA CMC 0,0047 % + 0,7 µA\n220 mA do 2,2 A CMC 0,008 % + 0,012 mA\n2,2 A do 20 A CMC 0,012% + 0,002 A\n20 A do 100 A CMC 0,7 % + 0,14 A\n100 A do 2500 A CMC 0,7 % + 0,84 A\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP-LME-04 Mierniki cegowe Wzorcowanie — Prad DC\nZakres:\n0 µA CMC 6,9 nA\n1 µA do 220 µA CMC 0,004 % + 6 nA\n220 µA do 2,2 mA CMC 0,002 % + 0,06 µA\n2,2 mA do 22 mA CMC 0,0034 % + 0,05 µA\n22 mA do 220 mA CMC 0,0047 % + 0,7 µA\n220 mA do 2,2 A CMC 0,008 % + 0,012 mA\n2,2 A do 20 A CMC 0,012% + 0,002 A\n20 A do 100 A CMC 0,7 % + 0,14 A\n100 A do 2500 A CMC 0,7 % + 0,84 A\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP-LME-04","search_en":"Clamp meters Calibration — DC current Internal procedure; At permanent location (S) DC current Internal procedure At permanent location (S) Internal procedure PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":26,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LME-04","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0 µA","cmc":"6,9 nA"},{"name":"","range":"1 µA to 220 µA","cmc":"0,004 % + 6 nA"},{"name":"","range":"220 µA to 2,2 mA","cmc":"0,002 % + 0,06 µA"},{"name":"","range":"2,2 mA to 22 mA","cmc":"0,0034 % + 0,05 µA"},{"name":"","range":"22 mA to 220 mA","cmc":"0,0047 % + 0,7 µA"},{"name":"","range":"220 mA to 2,2 A","cmc":"0,008 % + 0,012 mA"},{"name":"","range":"2,2 A to 20 A","cmc":"0,012% + 0,002 A"},{"name":"","range":"20 A to 100 A","cmc":"0,7 % + 0,14 A"},{"name":"","range":"100 A to 2500 A","cmc":"0,7 % + 0,84 A"}],"reference_de":"Internes Verfahren PP-LME-04","regulatory_area_de":"DC-Strom","search_de":"Zangenmessgeräte Kalibrierung — DC-Strom Internes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Am festen Standort (S) Internes Verfahren PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0 µA","cmc":"6,9 nA"},{"name":"","range":"1 µA to 220 µA","cmc":"0,004 % + 6 nA"},{"name":"","range":"220 µA to 2,2 mA","cmc":"0,002 % + 0,06 µA"},{"name":"","range":"2,2 mA to 22 mA","cmc":"0,0034 % + 0,05 µA"},{"name":"","range":"22 mA to 220 mA","cmc":"0,0047 % + 0,7 µA"},{"name":"","range":"220 mA to 2,2 A","cmc":"0,008 % + 0,012 mA"},{"name":"","range":"2,2 A to 20 A","cmc":"0,012% + 0,002 A"},{"name":"","range":"20 A to 100 A","cmc":"0,7 % + 0,14 A"},{"name":"","range":"100 A to 2500 A","cmc":"0,7 % + 0,84 A"}],"reference_zh":"内部程序 PP-LME-04","regulatory_area_zh":"直流电流","search_zh":"钳形表 校准 — 直流电流 内部程序；在固定地点 (S) 直流电流 内部程序 在固定地点 (S) 内部程序 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0 µA","cmc":"6,9 nA"},{"name":"","range":"1 µA to 220 µA","cmc":"0,004 % + 6 nA"},{"name":"","range":"220 µA to 2,2 mA","cmc":"0,002 % + 0,06 µA"},{"name":"","range":"2,2 mA to 22 mA","cmc":"0,0034 % + 0,05 µA"},{"name":"","range":"22 mA to 220 mA","cmc":"0,0047 % + 0,7 µA"},{"name":"","range":"220 mA to 2,2 A","cmc":"0,008 % + 0,012 mA"},{"name":"","range":"2,2 A to 20 A","cmc":"0,012% + 0,002 A"},{"name":"","range":"20 A to 100 A","cmc":"0,7 % + 0,14 A"},{"name":"","range":"100 A to 2500 A","cmc":"0,7 % + 0,84 A"}],"reference_cs":"Vnitřní postup PP-LME-04","regulatory_area_cs":"Proud DC","search_cs":"Klešťové měřiče Kalibrace — Proud DC Vnitřní postup; Ve stálé lokalitě (S) Proud DC Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Klešťové měřiče"},{"_id":"9d9bc19c1be70e632cc4ee4a","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Multimetry\nMierniki prądu analogowe i cyfrowe","test_object_en":"Multimeters\nAnalogue and digital ammeters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0 µA","cmc":"6,9 nA"},{"name":"","range":"1 µA do 220 µA","cmc":"0,004 % + 6 nA"},{"name":"","range":"220 µA do 2,2 mA","cmc":"0,002 % + 0,06 µA"},{"name":"","range":"2,2 mA do 22 mA","cmc":"0,0034 % + 0,05 µA"},{"name":"","range":"22 mA do 220 mA","cmc":"0,0047 % + 0,7 µA"},{"name":"","range":"220 mA do 2,2 A","cmc":"0,008 % + 0,012 mA"},{"name":"","range":"2,2 A do 20 A","cmc":"0,012% + 0,002 A"},{"name":"","range":"20 A do 100 A","cmc":"0,012% + 0,01 A"}],"parameters_en":[{"name":"","range":"0 µA","cmc":"6,9 nA"},{"name":"","range":"1 µA to 220 µA","cmc":"0,004 % + 6 nA"},{"name":"","range":"220 µA to 2,2 mA","cmc":"0,002 % + 0,06 µA"},{"name":"","range":"2,2 mA to 22 mA","cmc":"0,0034 % + 0,05 µA"},{"name":"","range":"22 mA to 220 mA","cmc":"0,0047 % + 0,7 µA"},{"name":"","range":"220 mA to 2,2 A","cmc":"0,008 % + 0,012 mA"},{"name":"","range":"2,2 A to 20 A","cmc":"0,012% + 0,002 A"},{"name":"","range":"20 A to 100 A","cmc":"0,012% + 0,01 A"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0 µA CMC 6,9 nA\n1 µA do 220 µA CMC 0,004 % + 6 nA\n220 µA do 2,2 mA CMC 0,002 % + 0,06 µA\n2,2 mA do 22 mA CMC 0,0034 % + 0,05 µA\n22 mA do 220 mA CMC 0,0047 % + 0,7 µA\n220 mA do 2,2 A CMC 0,008 % + 0,012 mA\n2,2 A do 20 A CMC 0,012% + 0,002 A\n20 A do 100 A CMC 0,012% + 0,01 A\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedury wewnętrzne PP-LME-03 PP-LME-04","norm_bases":["PP-LME-03","PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Multimetry\nMierniki prądu analogowe i cyfrowe Wzorcowanie — Prąd DC\nZakres:\n0 µA CMC 6,9 nA\n1 µA do 220 µA CMC 0,004 % + 6 nA\n220 µA do 2,2 mA CMC 0,002 % + 0,06 µA\n2,2 mA do 22 mA CMC 0,0034 % + 0,05 µA\n22 mA do 220 mA CMC 0,0047 % + 0,7 µA\n220 mA do 2,2 A CMC 0,008 % + 0,012 mA\n2,2 A do 20 A CMC 0,012% + 0,002 A\n20 A do 100 A CMC 0,012% + 0,01 A\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedury wewnętrzne PP-LME-03 PP-LME-04 Multimetry\nMierniki pradu analogowe i cyfrowe Wzorcowanie — Prad DC\nZakres:\n0 µA CMC 6,9 nA\n1 µA do 220 µA CMC 0,004 % + 6 nA\n220 µA do 2,2 mA CMC 0,002 % + 0,06 µA\n2,2 mA do 22 mA CMC 0,0034 % + 0,05 µA\n22 mA do 220 mA CMC 0,0047 % + 0,7 µA\n220 mA do 2,2 A CMC 0,008 % + 0,012 mA\n2,2 A do 20 A CMC 0,012% + 0,002 A\n20 A do 100 A CMC 0,012% + 0,01 A\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedury wewnetrzne PP-LME-03 PP-LME-04","search_en":"Multimeters Analogue and digital ammeters Calibration — DC current Internal procedure; At permanent location (S) DC current Internal procedure At permanent location (S) Internal procedures PP-LME-03 PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":27,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedures PP-LME-03 PP-LME-04","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0 µA","cmc":"6,9 nA"},{"name":"","range":"1 µA to 220 µA","cmc":"0,004 % + 6 nA"},{"name":"","range":"220 µA to 2,2 mA","cmc":"0,002 % + 0,06 µA"},{"name":"","range":"2,2 mA to 22 mA","cmc":"0,0034 % + 0,05 µA"},{"name":"","range":"22 mA to 220 mA","cmc":"0,0047 % + 0,7 µA"},{"name":"","range":"220 mA to 2,2 A","cmc":"0,008 % + 0,012 mA"},{"name":"","range":"2,2 A to 20 A","cmc":"0,012% + 0,002 A"},{"name":"","range":"20 A to 100 A","cmc":"0,012% + 0,01 A"}],"reference_de":"Interne Verfahren PP-LME-03 PP-LME-04","regulatory_area_de":"DC-Strom","search_de":"Multimeter Analoge und digitale Strommessgeräte Kalibrierung — DC-Strom Internes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Am festen Standort (S) Interne Verfahren PP-LME-03 PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter\nAnaloge und digitale Strommessgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0 µA","cmc":"6,9 nA"},{"name":"","range":"1 µA to 220 µA","cmc":"0,004 % + 6 nA"},{"name":"","range":"220 µA to 2,2 mA","cmc":"0,002 % + 0,06 µA"},{"name":"","range":"2,2 mA to 22 mA","cmc":"0,0034 % + 0,05 µA"},{"name":"","range":"22 mA to 220 mA","cmc":"0,0047 % + 0,7 µA"},{"name":"","range":"220 mA to 2,2 A","cmc":"0,008 % + 0,012 mA"},{"name":"","range":"2,2 A to 20 A","cmc":"0,012% + 0,002 A"},{"name":"","range":"20 A to 100 A","cmc":"0,012% + 0,01 A"}],"reference_zh":"内部程序 PP-LME-03 PP-LME-04","regulatory_area_zh":"直流电流","search_zh":"万用表 模拟和数字电流表 校准 — 直流电流 内部程序；在固定地点 (S) 直流电流 内部程序 在固定地点 (S) 内部程序 PP-LME-03 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"万用表\n模拟和数字电流表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0 µA","cmc":"6,9 nA"},{"name":"","range":"1 µA to 220 µA","cmc":"0,004 % + 6 nA"},{"name":"","range":"220 µA to 2,2 mA","cmc":"0,002 % + 0,06 µA"},{"name":"","range":"2,2 mA to 22 mA","cmc":"0,0034 % + 0,05 µA"},{"name":"","range":"22 mA to 220 mA","cmc":"0,0047 % + 0,7 µA"},{"name":"","range":"220 mA to 2,2 A","cmc":"0,008 % + 0,012 mA"},{"name":"","range":"2,2 A to 20 A","cmc":"0,012% + 0,002 A"},{"name":"","range":"20 A to 100 A","cmc":"0,012% + 0,01 A"}],"reference_cs":"Interní postupy PP-LME-03 PP-LME-04","regulatory_area_cs":"Proud DC","search_cs":"Multimetry Analogové a digitální měřiče proudu Kalibrace — Proud DC Vnitřní postup; Ve stálé lokalitě (S) Proud DC Vnitřní postup Ve stálé lokalitě (S) Interní postupy PP-LME-03 PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry\nAnalogové a digitální měřiče proudu"},{"_id":"30978de2a1dd2695f679e013","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Kalibratory\nZasilacze","test_object_en":"Calibrators\nPower supplies","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"10 Hz do 20 kHz","range":"1 mV do 100 mV","cmc":"0,034 % + 0,035 mV"},{"name":"10 Hz do 20 kHz","range":"100 mV do 1 V","cmc":"0,031 % + 0,38 mV"},{"name":"10 Hz do 20 kHz","range":"1 V do 10 V","cmc":"0,031 % + 3,8 mV"},{"name":"10 Hz do 20 kHz","range":"10 V do 100 V","cmc":"0,031 % + 0,038 V"},{"name":"10 Hz do 20 kHz","range":"100 V do 700 V","cmc":"0,029 % + 0,28 V"},{"name":"20 kHz do 50 kHz","range":"1 mV do 100 mV","cmc":"0,1 % + 0,058 mV"},{"name":"20 kHz do 50 kHz","range":"100 mV do 1 V","cmc":"0,098 % + 0,64 mV"},{"name":"20 kHz do 50 kHz","range":"1 V do 10 V","cmc":"0,098 % + 6,4 mV"},{"name":"20 kHz do 50 kHz","range":"10 V do 100 V","cmc":"0,098 % + 0,064 V"},{"name":"20 kHz do 50 kHz","range":"100 V do 700 V","cmc":"0,094 % + 0,47 V"},{"name":"50 kHz do 100 kHz","range":"1 mV do 100 mV","cmc":"0,6 % + 0,093 mV"},{"name":"50 kHz do 100 kHz","range":"100 mV do 1 V","cmc":"0,6 % + 1 mV"},{"name":"50 kHz do 100 kHz","range":"1 V do 10 V","cmc":"0,6 % + 0,01 V"},{"name":"50 kHz do 100 kHz","range":"10 V do 100 V","cmc":"0,6 % + 0,10 V"},{"name":"50 kHz do 100 kHz","range":"100 V do 700 V","cmc":"0,6 % + 0,75 V"}],"parameters_en":[{"name":"10 Hz to 20 kHz","range":"1 mV to 100 mV","cmc":"0,034 % + 0,035 mV"},{"name":"10 Hz to 20 kHz","range":"100 mV to 1 V","cmc":"0,031 % + 0,38 mV"},{"name":"10 Hz to 20 kHz","range":"1 V to 10 V","cmc":"0,031 % + 3,8 mV"},{"name":"10 Hz to 20 kHz","range":"10 V to 100 V","cmc":"0,031 % + 0,038 V"},{"name":"10 Hz to 20 kHz","range":"100 V to 700 V","cmc":"0,029 % + 0,28 V"},{"name":"20 kHz to 50 kHz","range":"1 mV to 100 mV","cmc":"0,1 % + 0,058 mV"},{"name":"20 kHz to 50 kHz","range":"100 mV to 1 V","cmc":"0,098 % + 0,64 mV"},{"name":"20 kHz to 50 kHz","range":"1 V to 10 V","cmc":"0,098 % + 6,4 mV"},{"name":"20 kHz to 50 kHz","range":"10 V to 100 V","cmc":"0,098 % + 0,064 V"},{"name":"20 kHz to 50 kHz","range":"100 V to 700 V","cmc":"0,094 % + 0,47 V"},{"name":"50 kHz to 100 kHz","range":"1 mV to 100 mV","cmc":"0,6 % + 0,093 mV"},{"name":"50 kHz to 100 kHz","range":"100 mV to 1 V","cmc":"0,6 % + 1 mV"},{"name":"50 kHz to 100 kHz","range":"1 V to 10 V","cmc":"0,6 % + 0,01 V"},{"name":"50 kHz to 100 kHz","range":"10 V to 100 V","cmc":"0,6 % + 0,10 V"},{"name":"50 kHz to 100 kHz","range":"100 V to 700 V","cmc":"0,6 % + 0,75 V"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 20 kHz 1 mV do 100 mV CMC 0,034 % + 0,035 mV\n10 Hz do 20 kHz 100 mV do 1 V CMC 0,031 % + 0,38 mV\n10 Hz do 20 kHz 1 V do 10 V CMC 0,031 % + 3,8 mV\n10 Hz do 20 kHz 10 V do 100 V CMC 0,031 % + 0,038 V\n10 Hz do 20 kHz 100 V do 700 V CMC 0,029 % + 0,28 V\n20 kHz do 50 kHz 1 mV do 100 mV CMC 0,1 % + 0,058 mV\n20 kHz do 50 kHz 100 mV do 1 V CMC 0,098 % + 0,64 mV\n20 kHz do 50 kHz 1 V do 10 V CMC 0,098 % + 6,4 mV\n20 kHz do 50 kHz 10 V do 100 V CMC 0,098 % + 0,064 V\n20 kHz do 50 kHz 100 V do 700 V CMC 0,094 % + 0,47 V\n50 kHz do 100 kHz 1 mV do 100 mV CMC 0,6 % + 0,093 mV\n50 kHz do 100 kHz 100 mV do 1 V CMC 0,6 % + 1 mV\n50 kHz do 100 kHz 1 V do 10 V CMC 0,6 % + 0,01 V\n50 kHz do 100 kHz 10 V do 100 V CMC 0,6 % + 0,10 V\n50 kHz do 100 kHz 100 V do 700 V CMC 0,6 % + 0,75 V\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LME-04","norm_bases":["PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kalibratory\nZasilacze Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 20 kHz 1 mV do 100 mV CMC 0,034 % + 0,035 mV\n10 Hz do 20 kHz 100 mV do 1 V CMC 0,031 % + 0,38 mV\n10 Hz do 20 kHz 1 V do 10 V CMC 0,031 % + 3,8 mV\n10 Hz do 20 kHz 10 V do 100 V CMC 0,031 % + 0,038 V\n10 Hz do 20 kHz 100 V do 700 V CMC 0,029 % + 0,28 V\n20 kHz do 50 kHz 1 mV do 100 mV CMC 0,1 % + 0,058 mV\n20 kHz do 50 kHz 100 mV do 1 V CMC 0,098 % + 0,64 mV\n20 kHz do 50 kHz 1 V do 10 V CMC 0,098 % + 6,4 mV\n20 kHz do 50 kHz 10 V do 100 V CMC 0,098 % + 0,064 V\n20 kHz do 50 kHz 100 V do 700 V CMC 0,094 % + 0,47 V\n50 kHz do 100 kHz 1 mV do 100 mV CMC 0,6 % + 0,093 mV\n50 kHz do 100 kHz 100 mV do 1 V CMC 0,6 % + 1 mV\n50 kHz do 100 kHz 1 V do 10 V CMC 0,6 % + 0,01 V\n50 kHz do 100 kHz 10 V do 100 V CMC 0,6 % + 0,10 V\n50 kHz do 100 kHz 100 V do 700 V CMC 0,6 % + 0,75 V\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP-LME-04 Kalibratory\nZasilacze Wzorcowanie — Napiecie AC\nZakres:\n10 Hz do 20 kHz 1 mV do 100 mV CMC 0,034 % + 0,035 mV\n10 Hz do 20 kHz 100 mV do 1 V CMC 0,031 % + 0,38 mV\n10 Hz do 20 kHz 1 V do 10 V CMC 0,031 % + 3,8 mV\n10 Hz do 20 kHz 10 V do 100 V CMC 0,031 % + 0,038 V\n10 Hz do 20 kHz 100 V do 700 V CMC 0,029 % + 0,28 V\n20 kHz do 50 kHz 1 mV do 100 mV CMC 0,1 % + 0,058 mV\n20 kHz do 50 kHz 100 mV do 1 V CMC 0,098 % + 0,64 mV\n20 kHz do 50 kHz 1 V do 10 V CMC 0,098 % + 6,4 mV\n20 kHz do 50 kHz 10 V do 100 V CMC 0,098 % + 0,064 V\n20 kHz do 50 kHz 100 V do 700 V CMC 0,094 % + 0,47 V\n50 kHz do 100 kHz 1 mV do 100 mV CMC 0,6 % + 0,093 mV\n50 kHz do 100 kHz 100 mV do 1 V CMC 0,6 % + 1 mV\n50 kHz do 100 kHz 1 V do 10 V CMC 0,6 % + 0,01 V\n50 kHz do 100 kHz 10 V do 100 V CMC 0,6 % + 0,10 V\n50 kHz do 100 kHz 100 V do 700 V CMC 0,6 % + 0,75 V\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP-LME-04","search_en":"Calibrators Power supplies Calibration — AC voltage Internal procedure; At permanent location (S) AC voltage Internal procedure At permanent location (S) 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz Internal procedure PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":28,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LME-04","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"10 Hz bis 20 kHz","range":"1 mV to 100 mV","cmc":"0,034 % + 0,035 mV"},{"name":"10 Hz bis 20 kHz","range":"100 mV to 1 V","cmc":"0,031 % + 0,38 mV"},{"name":"10 Hz bis 20 kHz","range":"1 V to 10 V","cmc":"0,031 % + 3,8 mV"},{"name":"10 Hz bis 20 kHz","range":"10 V to 100 V","cmc":"0,031 % + 0,038 V"},{"name":"10 Hz bis 20 kHz","range":"100 V to 700 V","cmc":"0,029 % + 0,28 V"},{"name":"20 kHz bis 50 kHz","range":"1 mV to 100 mV","cmc":"0,1 % + 0,058 mV"},{"name":"20 kHz bis 50 kHz","range":"100 mV to 1 V","cmc":"0,098 % + 0,64 mV"},{"name":"20 kHz bis 50 kHz","range":"1 V to 10 V","cmc":"0,098 % + 6,4 mV"},{"name":"20 kHz bis 50 kHz","range":"10 V to 100 V","cmc":"0,098 % + 0,064 V"},{"name":"20 kHz bis 50 kHz","range":"100 V to 700 V","cmc":"0,094 % + 0,47 V"},{"name":"50 kHz bis 100 kHz","range":"1 mV to 100 mV","cmc":"0,6 % + 0,093 mV"},{"name":"50 kHz bis 100 kHz","range":"100 mV to 1 V","cmc":"0,6 % + 1 mV"},{"name":"50 kHz bis 100 kHz","range":"1 V to 10 V","cmc":"0,6 % + 0,01 V"},{"name":"50 kHz bis 100 kHz","range":"10 V to 100 V","cmc":"0,6 % + 0,10 V"},{"name":"50 kHz bis 100 kHz","range":"100 V to 700 V","cmc":"0,6 % + 0,75 V"}],"reference_de":"Internes Verfahren PP-LME-04","regulatory_area_de":"AC-Spannung","search_de":"Kalibratoren Netzgeräte Kalibrierung — Wechselspannung Internes Verfahren; Am festen Standort (S) AC-Spannung Internes Verfahren Am festen Standort (S) 10 Hz bis 20 kHz 10 Hz bis 20 kHz 10 Hz bis 20 kHz 10 Hz bis 20 kHz 10 Hz bis 20 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz Internes Verfahren PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nNetzgeräte","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"10 Hz 至 20 kHz","range":"1 mV to 100 mV","cmc":"0,034 % + 0,035 mV"},{"name":"10 Hz 至 20 kHz","range":"100 mV to 1 V","cmc":"0,031 % + 0,38 mV"},{"name":"10 Hz 至 20 kHz","range":"1 V to 10 V","cmc":"0,031 % + 3,8 mV"},{"name":"10 Hz 至 20 kHz","range":"10 V to 100 V","cmc":"0,031 % + 0,038 V"},{"name":"10 Hz 至 20 kHz","range":"100 V to 700 V","cmc":"0,029 % + 0,28 V"},{"name":"20 kHz 至 50 kHz","range":"1 mV to 100 mV","cmc":"0,1 % + 0,058 mV"},{"name":"20 kHz 至 50 kHz","range":"100 mV to 1 V","cmc":"0,098 % + 0,64 mV"},{"name":"20 kHz 至 50 kHz","range":"1 V to 10 V","cmc":"0,098 % + 6,4 mV"},{"name":"20 kHz 至 50 kHz","range":"10 V to 100 V","cmc":"0,098 % + 0,064 V"},{"name":"20 kHz 至 50 kHz","range":"100 V to 700 V","cmc":"0,094 % + 0,47 V"},{"name":"50 kHz 至 100 kHz","range":"1 mV to 100 mV","cmc":"0,6 % + 0,093 mV"},{"name":"50 kHz 至 100 kHz","range":"100 mV to 1 V","cmc":"0,6 % + 1 mV"},{"name":"50 kHz 至 100 kHz","range":"1 V to 10 V","cmc":"0,6 % + 0,01 V"},{"name":"50 kHz 至 100 kHz","range":"10 V to 100 V","cmc":"0,6 % + 0,10 V"},{"name":"50 kHz 至 100 kHz","range":"100 V to 700 V","cmc":"0,6 % + 0,75 V"}],"reference_zh":"内部程序 PP-LME-04","regulatory_area_zh":"交流电压","search_zh":"校准器 电源 校准 — 交流电压 内部程序；在固定地点 (S) 交流电压 内部程序 在固定地点 (S) 10 Hz 至 20 kHz 10 Hz 至 20 kHz 10 Hz 至 20 kHz 10 Hz 至 20 kHz 10 Hz 至 20 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 内部程序 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器\n电源","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"10 Hz až 20 kHz","range":"1 mV to 100 mV","cmc":"0,034 % + 0,035 mV"},{"name":"10 Hz až 20 kHz","range":"100 mV to 1 V","cmc":"0,031 % + 0,38 mV"},{"name":"10 Hz až 20 kHz","range":"1 V to 10 V","cmc":"0,031 % + 3,8 mV"},{"name":"10 Hz až 20 kHz","range":"10 V to 100 V","cmc":"0,031 % + 0,038 V"},{"name":"10 Hz až 20 kHz","range":"100 V to 700 V","cmc":"0,029 % + 0,28 V"},{"name":"20 kHz až 50 kHz","range":"1 mV to 100 mV","cmc":"0,1 % + 0,058 mV"},{"name":"20 kHz až 50 kHz","range":"100 mV to 1 V","cmc":"0,098 % + 0,64 mV"},{"name":"20 kHz až 50 kHz","range":"1 V to 10 V","cmc":"0,098 % + 6,4 mV"},{"name":"20 kHz až 50 kHz","range":"10 V to 100 V","cmc":"0,098 % + 0,064 V"},{"name":"20 kHz až 50 kHz","range":"100 V to 700 V","cmc":"0,094 % + 0,47 V"},{"name":"50 kHz až 100 kHz","range":"1 mV to 100 mV","cmc":"0,6 % + 0,093 mV"},{"name":"50 kHz až 100 kHz","range":"100 mV to 1 V","cmc":"0,6 % + 1 mV"},{"name":"50 kHz až 100 kHz","range":"1 V to 10 V","cmc":"0,6 % + 0,01 V"},{"name":"50 kHz až 100 kHz","range":"10 V to 100 V","cmc":"0,6 % + 0,10 V"},{"name":"50 kHz až 100 kHz","range":"100 V to 700 V","cmc":"0,6 % + 0,75 V"}],"reference_cs":"Vnitřní postup PP-LME-04","regulatory_area_cs":"Napětí AC","search_cs":"Kalibrátory Napájecí zdroje Kalibrace — Napětí AC Vnitřní postup; Ve stálé lokalitě (S) Napětí AC Vnitřní postup Ve stálé lokalitě (S) 10 Hz až 20 kHz 10 Hz až 20 kHz 10 Hz až 20 kHz 10 Hz až 20 kHz 10 Hz až 20 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz Vnitřní postup PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nNapájecí zdroje"},{"_id":"6b93921bd9274a7a36eaabd1","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Mierniki napięcia analogowe i cyfrowe\nMultimetry\nSondy napięciowe","test_object_en":"Analogue and digital voltmeters\nMultimeters\nVoltage probes","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"40 Hz do 20 kHz","range":"1 mV do 2,2 mV","cmc":"0,0083 % + 4 µV"},{"name":"40 Hz do 20 kHz","range":"2,2 mV do 22 mV","cmc":"0,005 % + 8 µV"},{"name":"40 Hz do 20 kHz","range":"22 mV do 220 mV","cmc":"0,005 % + 7 µV"},{"name":"40 Hz do 20 kHz","range":"220 mV do 2,2 V","cmc":"0,004 % + 0,011 mV"},{"name":"40 Hz do 20 kHz","range":"2,2 V do 22 V","cmc":"0,0042 % + 0,05 mV"},{"name":"40 Hz do 20 kHz","range":"22 V do 220 V","cmc":"0,0052 % + 0,6 mV"},{"name":"20 kHz do 50 kHz","range":"1 mV do 22 mV","cmc":"0,02 % + 4 µV"},{"name":"20 kHz do 50 kHz","range":"22 mV do 220 mV","cmc":"0,012 % + 7 µV"},{"name":"20 kHz do 50 kHz","range":"220 mV do 2,2 V","cmc":"0,0061 % + 0,02 mV"},{"name":"20 kHz do 50 kHz","range":"2,2 V do 22 V","cmc":"0,007 % + 0,02 mV"},{"name":"20 kHz do 50 kHz","range":"22 V do 220 V","cmc":"0,008 % + 1 mV"},{"name":"50 kHz do 100 kHz","range":"1 mV do 22 mV","cmc":"0,05 % + 5 µV"},{"name":"50 kHz do 100 kHz","range":"22 mV do 220 mV","cmc":"0,031 % + 17 µV"},{"name":"50 kHz do 100 kHz","range":"220 mV do 2,2 V","cmc":"0,0081 % + 0,032 mV"},{"name":"50 kHz do 100 kHz","range":"2,2 V do 22 V","cmc":"0,0083 % + 0,2 mV"},{"name":"50 kHz do 100 kHz","range":"22 V do 220 V","cmc":"0,015 % + 2,6 mV"},{"name":"100 kHz do 300 kHz","range":"1 mV do 22 mV","cmc":"0,11 % + 0,01 mV"},{"name":"100 kHz do 300 kHz","range":"22 mV do 220 mV","cmc":"0,065 % + 0,02 mV"},{"name":"100 kHz do 300 kHz","range":"220 mV do 2,2 V","cmc":"0,033 % + 0,08 mV"},{"name":"100 kHz do 300 kHz","range":"2,2 V do 22 V","cmc":"0,025 % + 0,6 mV"},{"name":"100 kHz do 300 kHz","range":"22 V do 220 V","cmc":"0,09 % + 16 mV"},{"name":"40 Hz do 50 Hz","range":"220 V do 1100 V","cmc":"0,03 % + 0,016 V"},{"name":"50 Hz do 1 kHz","range":"220 V do 1100 V","cmc":"0,007 % + 0,004 V"},{"name":"1 kHz do 20 kHz","range":"220 V do 1100 V","cmc":"0,024 % + 0,46 V"},{"name":"20 kHz do 50 kHz","range":"220 V do 1100 V","cmc":"0,053 % + 0,78 V"},{"name":"50 kHz do 100 kHz","range":"220 V do 1100 V","cmc":"0,036 % + 1,8 V"}],"parameters_en":[{"name":"40 Hz to 20 kHz","range":"1 mV to 2,2 mV","cmc":"0,0083 % + 4 µV"},{"name":"40 Hz to 20 kHz","range":"2,2 mV to 22 mV","cmc":"0,005 % + 8 µV"},{"name":"40 Hz to 20 kHz","range":"22 mV to 220 mV","cmc":"0,005 % + 7 µV"},{"name":"40 Hz to 20 kHz","range":"220 mV to 2,2 V","cmc":"0,004 % + 0,011 mV"},{"name":"40 Hz to 20 kHz","range":"2,2 V to 22 V","cmc":"0,0042 % + 0,05 mV"},{"name":"40 Hz to 20 kHz","range":"22 V to 220 V","cmc":"0,0052 % + 0,6 mV"},{"name":"20 kHz to 50 kHz","range":"1 mV to 22 mV","cmc":"0,02 % + 4 µV"},{"name":"20 kHz to 50 kHz","range":"22 mV to 220 mV","cmc":"0,012 % + 7 µV"},{"name":"20 kHz to 50 kHz","range":"220 mV to 2,2 V","cmc":"0,0061 % + 0,02 mV"},{"name":"20 kHz to 50 kHz","range":"2,2 V to 22 V","cmc":"0,007 % + 0,02 mV"},{"name":"20 kHz to 50 kHz","range":"22 V to 220 V","cmc":"0,008 % + 1 mV"},{"name":"50 kHz to 100 kHz","range":"1 mV to 22 mV","cmc":"0,05 % + 5 µV"},{"name":"50 kHz to 100 kHz","range":"22 mV to 220 mV","cmc":"0,031 % + 17 µV"},{"name":"50 kHz to 100 kHz","range":"220 mV to 2,2 V","cmc":"0,0081 % + 0,032 mV"},{"name":"50 kHz to 100 kHz","range":"2,2 V to 22 V","cmc":"0,0083 % + 0,2 mV"},{"name":"50 kHz to 100 kHz","range":"22 V to 220 V","cmc":"0,015 % + 2,6 mV"},{"name":"100 kHz to 300 kHz","range":"1 mV to 22 mV","cmc":"0,11 % + 0,01 mV"},{"name":"100 kHz to 300 kHz","range":"22 mV to 220 mV","cmc":"0,065 % + 0,02 mV"},{"name":"100 kHz to 300 kHz","range":"220 mV to 2,2 V","cmc":"0,033 % + 0,08 mV"},{"name":"100 kHz to 300 kHz","range":"2,2 V to 22 V","cmc":"0,025 % + 0,6 mV"},{"name":"100 kHz to 300 kHz","range":"22 V to 220 V","cmc":"0,09 % + 16 mV"},{"name":"40 Hz to 50 Hz","range":"220 V to 1100 V","cmc":"0,03 % + 0,016 V"},{"name":"50 Hz to 1 kHz","range":"220 V to 1100 V","cmc":"0,007 % + 0,004 V"},{"name":"1 kHz to 20 kHz","range":"220 V to 1100 V","cmc":"0,024 % + 0,46 V"},{"name":"20 kHz to 50 kHz","range":"220 V to 1100 V","cmc":"0,053 % + 0,78 V"},{"name":"50 kHz to 100 kHz","range":"220 V to 1100 V","cmc":"0,036 % + 1,8 V"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 20 kHz 1 mV do 2,2 mV CMC 0,0083 % + 4 µV\n40 Hz do 20 kHz 2,2 mV do 22 mV CMC 0,005 % + 8 µV\n40 Hz do 20 kHz 22 mV do 220 mV CMC 0,005 % + 7 µV\n40 Hz do 20 kHz 220 mV do 2,2 V CMC 0,004 % + 0,011 mV\n40 Hz do 20 kHz 2,2 V do 22 V CMC 0,0042 % + 0,05 mV\n40 Hz do 20 kHz 22 V do 220 V CMC 0,0052 % + 0,6 mV\n20 kHz do 50 kHz 1 mV do 22 mV CMC 0,02 % + 4 µV\n20 kHz do 50 kHz 22 mV do 220 mV CMC 0,012 % + 7 µV\n20 kHz do 50 kHz 220 mV do 2,2 V CMC 0,0061 % + 0,02 mV\n20 kHz do 50 kHz 2,2 V do 22 V CMC 0,007 % + 0,02 mV\n20 kHz do 50 kHz 22 V do 220 V CMC 0,008 % + 1 mV\n50 kHz do 100 kHz 1 mV do 22 mV CMC 0,05 % + 5 µV\n50 kHz do 100 kHz 22 mV do 220 mV CMC 0,031 % + 17 µV\n50 kHz do 100 kHz 220 mV do 2,2 V CMC 0,0081 % + 0,032 mV\n50 kHz do 100 kHz 2,2 V do 22 V CMC 0,0083 % + 0,2 mV\n50 kHz do 100 kHz 22 V do 220 V CMC 0,015 % + 2,6 mV\n100 kHz do 300 kHz 1 mV do 22 mV CMC 0,11 % + 0,01 mV\n100 kHz do 300 kHz 22 mV do 220 mV CMC 0,065 % + 0,02 mV\n100 kHz do 300 kHz 220 mV do 2,2 V CMC 0,033 % + 0,08 mV\n100 kHz do 300 kHz 2,2 V do 22 V CMC 0,025 % + 0,6 mV\n100 kHz do 300 kHz 22 V do 220 V CMC 0,09 % + 16 mV\n40 Hz do 50 Hz 220 V do 1100 V CMC 0,03 % + 0,016 V\n50 Hz do 1 kHz 220 V do 1100 V CMC 0,007 % + 0,004 V\n1 kHz do 20 kHz 220 V do 1100 V CMC 0,024 % + 0,46 V\n20 kHz do 50 kHz 220 V do 1100 V CMC 0,053 % + 0,78 V\n50 kHz do 100 kHz 220 V do 1100 V CMC 0,036 % + 1,8 V\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedury wewnętrzne PP-LME-03 PP-LME-04","norm_bases":["PP-LME-03","PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki napięcia analogowe i cyfrowe\nMultimetry\nSondy napięciowe Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 20 kHz 1 mV do 2,2 mV CMC 0,0083 % + 4 µV\n40 Hz do 20 kHz 2,2 mV do 22 mV CMC 0,005 % + 8 µV\n40 Hz do 20 kHz 22 mV do 220 mV CMC 0,005 % + 7 µV\n40 Hz do 20 kHz 220 mV do 2,2 V CMC 0,004 % + 0,011 mV\n40 Hz do 20 kHz 2,2 V do 22 V CMC 0,0042 % + 0,05 mV\n40 Hz do 20 kHz 22 V do 220 V CMC 0,0052 % + 0,6 mV\n20 kHz do 50 kHz 1 mV do 22 mV CMC 0,02 % + 4 µV\n20 kHz do 50 kHz 22 mV do 220 mV CMC 0,012 % + 7 µV\n20 kHz do 50 kHz 220 mV do 2,2 V CMC 0,0061 % + 0,02 mV\n20 kHz do 50 kHz 2,2 V do 22 V CMC 0,007 % + 0,02 mV\n20 kHz do 50 kHz 22 V do 220 V CMC 0,008 % + 1 mV\n50 kHz do 100 kHz 1 mV do 22 mV CMC 0,05 % + 5 µV\n50 kHz do 100 kHz 22 mV do 220 mV CMC 0,031 % + 17 µV\n50 kHz do 100 kHz 220 mV do 2,2 V CMC 0,0081 % + 0,032 mV\n50 kHz do 100 kHz 2,2 V do 22 V CMC 0,0083 % + 0,2 mV\n50 kHz do 100 kHz 22 V do 220 V CMC 0,015 % + 2,6 mV\n100 kHz do 300 kHz 1 mV do 22 mV CMC 0,11 % + 0,01 mV\n100 kHz do 300 kHz 22 mV do 220 mV CMC 0,065 % + 0,02 mV\n100 kHz do 300 kHz 220 mV do 2,2 V CMC 0,033 % + 0,08 mV\n100 kHz do 300 kHz 2,2 V do 22 V CMC 0,025 % + 0,6 mV\n100 kHz do 300 kHz 22 V do 220 V CMC 0,09 % + 16 mV\n40 Hz do 50 Hz 220 V do 1100 V CMC 0,03 % + 0,016 V\n50 Hz do 1 kHz 220 V do 1100 V CMC 0,007 % + 0,004 V\n1 kHz do 20 kHz 220 V do 1100 V CMC 0,024 % + 0,46 V\n20 kHz do 50 kHz 220 V do 1100 V CMC 0,053 % + 0,78 V\n50 kHz do 100 kHz 220 V do 1100 V CMC 0,036 % + 1,8 V\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedury wewnętrzne PP-LME-03 PP-LME-04 Mierniki napiecia analogowe i cyfrowe\nMultimetry\nSondy napieciowe Wzorcowanie — Napiecie AC\nZakres:\n40 Hz do 20 kHz 1 mV do 2,2 mV CMC 0,0083 % + 4 µV\n40 Hz do 20 kHz 2,2 mV do 22 mV CMC 0,005 % + 8 µV\n40 Hz do 20 kHz 22 mV do 220 mV CMC 0,005 % + 7 µV\n40 Hz do 20 kHz 220 mV do 2,2 V CMC 0,004 % + 0,011 mV\n40 Hz do 20 kHz 2,2 V do 22 V CMC 0,0042 % + 0,05 mV\n40 Hz do 20 kHz 22 V do 220 V CMC 0,0052 % + 0,6 mV\n20 kHz do 50 kHz 1 mV do 22 mV CMC 0,02 % + 4 µV\n20 kHz do 50 kHz 22 mV do 220 mV CMC 0,012 % + 7 µV\n20 kHz do 50 kHz 220 mV do 2,2 V CMC 0,0061 % + 0,02 mV\n20 kHz do 50 kHz 2,2 V do 22 V CMC 0,007 % + 0,02 mV\n20 kHz do 50 kHz 22 V do 220 V CMC 0,008 % + 1 mV\n50 kHz do 100 kHz 1 mV do 22 mV CMC 0,05 % + 5 µV\n50 kHz do 100 kHz 22 mV do 220 mV CMC 0,031 % + 17 µV\n50 kHz do 100 kHz 220 mV do 2,2 V CMC 0,0081 % + 0,032 mV\n50 kHz do 100 kHz 2,2 V do 22 V CMC 0,0083 % + 0,2 mV\n50 kHz do 100 kHz 22 V do 220 V CMC 0,015 % + 2,6 mV\n100 kHz do 300 kHz 1 mV do 22 mV CMC 0,11 % + 0,01 mV\n100 kHz do 300 kHz 22 mV do 220 mV CMC 0,065 % + 0,02 mV\n100 kHz do 300 kHz 220 mV do 2,2 V CMC 0,033 % + 0,08 mV\n100 kHz do 300 kHz 2,2 V do 22 V CMC 0,025 % + 0,6 mV\n100 kHz do 300 kHz 22 V do 220 V CMC 0,09 % + 16 mV\n40 Hz do 50 Hz 220 V do 1100 V CMC 0,03 % + 0,016 V\n50 Hz do 1 kHz 220 V do 1100 V CMC 0,007 % + 0,004 V\n1 kHz do 20 kHz 220 V do 1100 V CMC 0,024 % + 0,46 V\n20 kHz do 50 kHz 220 V do 1100 V CMC 0,053 % + 0,78 V\n50 kHz do 100 kHz 220 V do 1100 V CMC 0,036 % + 1,8 V\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedury wewnetrzne PP-LME-03 PP-LME-04","search_en":"Analogue and digital voltmeters Multimeters Voltage probes Calibration — AC voltage Internal procedure; At permanent location (S) AC voltage Internal procedure At permanent location (S) 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 40 Hz to 50 Hz 50 Hz to 1 kHz 1 kHz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz Internal procedures PP-LME-03 PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":29,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedures PP-LME-03 PP-LME-04","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"40 Hz bis 20 kHz","range":"1 mV to 2,2 mV","cmc":"0,0083 % + 4 µV"},{"name":"40 Hz bis 20 kHz","range":"2,2 mV to 22 mV","cmc":"0,005 % + 8 µV"},{"name":"40 Hz bis 20 kHz","range":"22 mV to 220 mV","cmc":"0,005 % + 7 µV"},{"name":"40 Hz bis 20 kHz","range":"220 mV to 2,2 V","cmc":"0,004 % + 0,011 mV"},{"name":"40 Hz bis 20 kHz","range":"2,2 V to 22 V","cmc":"0,0042 % + 0,05 mV"},{"name":"40 Hz bis 20 kHz","range":"22 V to 220 V","cmc":"0,0052 % + 0,6 mV"},{"name":"20 kHz bis 50 kHz","range":"1 mV to 22 mV","cmc":"0,02 % + 4 µV"},{"name":"20 kHz bis 50 kHz","range":"22 mV to 220 mV","cmc":"0,012 % + 7 µV"},{"name":"20 kHz bis 50 kHz","range":"220 mV to 2,2 V","cmc":"0,0061 % + 0,02 mV"},{"name":"20 kHz bis 50 kHz","range":"2,2 V to 22 V","cmc":"0,007 % + 0,02 mV"},{"name":"20 kHz bis 50 kHz","range":"22 V to 220 V","cmc":"0,008 % + 1 mV"},{"name":"50 kHz bis 100 kHz","range":"1 mV to 22 mV","cmc":"0,05 % + 5 µV"},{"name":"50 kHz bis 100 kHz","range":"22 mV to 220 mV","cmc":"0,031 % + 17 µV"},{"name":"50 kHz bis 100 kHz","range":"220 mV to 2,2 V","cmc":"0,0081 % + 0,032 mV"},{"name":"50 kHz bis 100 kHz","range":"2,2 V to 22 V","cmc":"0,0083 % + 0,2 mV"},{"name":"50 kHz bis 100 kHz","range":"22 V to 220 V","cmc":"0,015 % + 2,6 mV"},{"name":"100 kHz bis 300 kHz","range":"1 mV to 22 mV","cmc":"0,11 % + 0,01 mV"},{"name":"100 kHz bis 300 kHz","range":"22 mV to 220 mV","cmc":"0,065 % + 0,02 mV"},{"name":"100 kHz bis 300 kHz","range":"220 mV to 2,2 V","cmc":"0,033 % + 0,08 mV"},{"name":"100 kHz bis 300 kHz","range":"2,2 V to 22 V","cmc":"0,025 % + 0,6 mV"},{"name":"100 kHz bis 300 kHz","range":"22 V to 220 V","cmc":"0,09 % + 16 mV"},{"name":"40 Hz bis 50 Hz","range":"220 V to 1100 V","cmc":"0,03 % + 0,016 V"},{"name":"50 Hz bis 1 kHz","range":"220 V to 1100 V","cmc":"0,007 % + 0,004 V"},{"name":"1 kHz bis 20 kHz","range":"220 V to 1100 V","cmc":"0,024 % + 0,46 V"},{"name":"20 kHz bis 50 kHz","range":"220 V to 1100 V","cmc":"0,053 % + 0,78 V"},{"name":"50 kHz bis 100 kHz","range":"220 V to 1100 V","cmc":"0,036 % + 1,8 V"}],"reference_de":"Interne Verfahren PP-LME-03 PP-LME-04","regulatory_area_de":"AC-Spannung","search_de":"Analoge und digitale Spannungsmessgeräte Multimeter Spannungstastköpfe Kalibrierung — Wechselspannung Internes Verfahren; Am festen Standort (S) AC-Spannung Internes Verfahren Am festen Standort (S) 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 40 Hz bis 50 Hz 50 Hz bis 1 kHz 1 kHz bis 20 kHz 20 kHz bis 50 kHz 50 kHz bis 100 kHz Interne Verfahren PP-LME-03 PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge und digitale Spannungsmessgeräte\nMultimeter\nSpannungstastköpfe","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"40 Hz 至 20 kHz","range":"1 mV to 2,2 mV","cmc":"0,0083 % + 4 µV"},{"name":"40 Hz 至 20 kHz","range":"2,2 mV to 22 mV","cmc":"0,005 % + 8 µV"},{"name":"40 Hz 至 20 kHz","range":"22 mV to 220 mV","cmc":"0,005 % + 7 µV"},{"name":"40 Hz 至 20 kHz","range":"220 mV to 2,2 V","cmc":"0,004 % + 0,011 mV"},{"name":"40 Hz 至 20 kHz","range":"2,2 V to 22 V","cmc":"0,0042 % + 0,05 mV"},{"name":"40 Hz 至 20 kHz","range":"22 V to 220 V","cmc":"0,0052 % + 0,6 mV"},{"name":"20 kHz 至 50 kHz","range":"1 mV to 22 mV","cmc":"0,02 % + 4 µV"},{"name":"20 kHz 至 50 kHz","range":"22 mV to 220 mV","cmc":"0,012 % + 7 µV"},{"name":"20 kHz 至 50 kHz","range":"220 mV to 2,2 V","cmc":"0,0061 % + 0,02 mV"},{"name":"20 kHz 至 50 kHz","range":"2,2 V to 22 V","cmc":"0,007 % + 0,02 mV"},{"name":"20 kHz 至 50 kHz","range":"22 V to 220 V","cmc":"0,008 % + 1 mV"},{"name":"50 kHz 至 100 kHz","range":"1 mV to 22 mV","cmc":"0,05 % + 5 µV"},{"name":"50 kHz 至 100 kHz","range":"22 mV to 220 mV","cmc":"0,031 % + 17 µV"},{"name":"50 kHz 至 100 kHz","range":"220 mV to 2,2 V","cmc":"0,0081 % + 0,032 mV"},{"name":"50 kHz 至 100 kHz","range":"2,2 V to 22 V","cmc":"0,0083 % + 0,2 mV"},{"name":"50 kHz 至 100 kHz","range":"22 V to 220 V","cmc":"0,015 % + 2,6 mV"},{"name":"100 kHz 至 300 kHz","range":"1 mV to 22 mV","cmc":"0,11 % + 0,01 mV"},{"name":"100 kHz 至 300 kHz","range":"22 mV to 220 mV","cmc":"0,065 % + 0,02 mV"},{"name":"100 kHz 至 300 kHz","range":"220 mV to 2,2 V","cmc":"0,033 % + 0,08 mV"},{"name":"100 kHz 至 300 kHz","range":"2,2 V to 22 V","cmc":"0,025 % + 0,6 mV"},{"name":"100 kHz 至 300 kHz","range":"22 V to 220 V","cmc":"0,09 % + 16 mV"},{"name":"40 Hz 至 50 Hz","range":"220 V to 1100 V","cmc":"0,03 % + 0,016 V"},{"name":"50 Hz 至 1 kHz","range":"220 V to 1100 V","cmc":"0,007 % + 0,004 V"},{"name":"1 kHz 至 20 kHz","range":"220 V to 1100 V","cmc":"0,024 % + 0,46 V"},{"name":"20 kHz 至 50 kHz","range":"220 V to 1100 V","cmc":"0,053 % + 0,78 V"},{"name":"50 kHz 至 100 kHz","range":"220 V to 1100 V","cmc":"0,036 % + 1,8 V"}],"reference_zh":"内部程序 PP-LME-03 PP-LME-04","regulatory_area_zh":"交流电压","search_zh":"模拟和数字电压表 万用表 电压探头 校准 — 交流电压 内部程序；在固定地点 (S) 交流电压 内部程序 在固定地点 (S) 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 40 Hz 至 50 Hz 50 Hz 至 1 kHz 1 kHz 至 20 kHz 20 kHz 至 50 kHz 50 kHz 至 100 kHz 内部程序 PP-LME-03 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"模拟和数字电压表\n万用表\n电压探头","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"40 Hz až 20 kHz","range":"1 mV to 2,2 mV","cmc":"0,0083 % + 4 µV"},{"name":"40 Hz až 20 kHz","range":"2,2 mV to 22 mV","cmc":"0,005 % + 8 µV"},{"name":"40 Hz až 20 kHz","range":"22 mV to 220 mV","cmc":"0,005 % + 7 µV"},{"name":"40 Hz až 20 kHz","range":"220 mV to 2,2 V","cmc":"0,004 % + 0,011 mV"},{"name":"40 Hz až 20 kHz","range":"2,2 V to 22 V","cmc":"0,0042 % + 0,05 mV"},{"name":"40 Hz až 20 kHz","range":"22 V to 220 V","cmc":"0,0052 % + 0,6 mV"},{"name":"20 kHz až 50 kHz","range":"1 mV to 22 mV","cmc":"0,02 % + 4 µV"},{"name":"20 kHz až 50 kHz","range":"22 mV to 220 mV","cmc":"0,012 % + 7 µV"},{"name":"20 kHz až 50 kHz","range":"220 mV to 2,2 V","cmc":"0,0061 % + 0,02 mV"},{"name":"20 kHz až 50 kHz","range":"2,2 V to 22 V","cmc":"0,007 % + 0,02 mV"},{"name":"20 kHz až 50 kHz","range":"22 V to 220 V","cmc":"0,008 % + 1 mV"},{"name":"50 kHz až 100 kHz","range":"1 mV to 22 mV","cmc":"0,05 % + 5 µV"},{"name":"50 kHz až 100 kHz","range":"22 mV to 220 mV","cmc":"0,031 % + 17 µV"},{"name":"50 kHz až 100 kHz","range":"220 mV to 2,2 V","cmc":"0,0081 % + 0,032 mV"},{"name":"50 kHz až 100 kHz","range":"2,2 V to 22 V","cmc":"0,0083 % + 0,2 mV"},{"name":"50 kHz až 100 kHz","range":"22 V to 220 V","cmc":"0,015 % + 2,6 mV"},{"name":"100 kHz až 300 kHz","range":"1 mV to 22 mV","cmc":"0,11 % + 0,01 mV"},{"name":"100 kHz až 300 kHz","range":"22 mV to 220 mV","cmc":"0,065 % + 0,02 mV"},{"name":"100 kHz až 300 kHz","range":"220 mV to 2,2 V","cmc":"0,033 % + 0,08 mV"},{"name":"100 kHz až 300 kHz","range":"2,2 V to 22 V","cmc":"0,025 % + 0,6 mV"},{"name":"100 kHz až 300 kHz","range":"22 V to 220 V","cmc":"0,09 % + 16 mV"},{"name":"40 Hz až 50 Hz","range":"220 V to 1100 V","cmc":"0,03 % + 0,016 V"},{"name":"50 Hz až 1 kHz","range":"220 V to 1100 V","cmc":"0,007 % + 0,004 V"},{"name":"1 kHz až 20 kHz","range":"220 V to 1100 V","cmc":"0,024 % + 0,46 V"},{"name":"20 kHz až 50 kHz","range":"220 V to 1100 V","cmc":"0,053 % + 0,78 V"},{"name":"50 kHz až 100 kHz","range":"220 V to 1100 V","cmc":"0,036 % + 1,8 V"}],"reference_cs":"Interní postupy PP-LME-03 PP-LME-04","regulatory_area_cs":"Napětí AC","search_cs":"Analogové a digitální měřiče napětí Multimetry Napěťové sondy Kalibrace — Napětí AC Vnitřní postup; Ve stálé lokalitě (S) Napětí AC Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 40 Hz až 50 Hz 50 Hz až 1 kHz 1 kHz až 20 kHz 20 kHz až 50 kHz 50 kHz až 100 kHz Interní postupy PP-LME-03 PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové a digitální měřiče napětí\nMultimetry\nNapěťové sondy"},{"_id":"216d593f1cb135970e8dff8b","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Kalibratory","test_object_en":"Calibrators","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"10 Hz do 2 kHz","range":"100 µA do 1 mA","cmc":"0,053 % + 0,4 µA"},{"name":"10 Hz do 2 kHz","range":"1 mA do 10 mA","cmc":"0,054 % + 4 µA"},{"name":"10 Hz do 2 kHz","range":"10 mA do 100 mA","cmc":"0,054 % 0,04 mA"},{"name":"10 Hz do 2 kHz","range":"100 mA do 1 A","cmc":"0,18 % 0,51 mA"},{"name":"10 Hz do 2 kHz","range":"1 A do 3 A","cmc":"0,14 % + 2,6 mA"},{"name":"10 Hz do 2 kHz","range":"3 A do 10 A","cmc":"0,38 % + 8,3 mA"},{"name":"2 kHz do 5 kHz","range":"100 µA do 1 mA","cmc":"0,066 % + 0,4 µA"},{"name":"2 kHz do 5 kHz","range":"1 mA do 10 mA","cmc":"0,066 % + 4 µA"},{"name":"2 kHz do 5 kHz","range":"10 mA do 100 mA","cmc":"0,066 % + 0,04 mA"},{"name":"2 kHz do 5 kHz","range":"100 mA do 1 A","cmc":"0,96 % + 0,51 mA"},{"name":"2 kHz do 5 kHz","range":"1 A do 3 A","cmc":"0,93 % + 2,6 mA"},{"name":"2 kHz do 5 kHz","range":"3 A do 10 A","cmc":"0,93 % + 8,2 mA"},{"name":"5 kHz do 10 kHz","range":"100 µA do 1 mA","cmc":"0,066 % + 0,4 µA"},{"name":"5 kHz do 10 kHz","range":"1 mA do 10 mA","cmc":"0,066 % + 4 µA"},{"name":"5 kHz do 10 kHz","range":"10 mA do 100 mA","cmc":"0,0045 % + 8 µA"},{"name":"5 kHz do 10 kHz","range":"100 mA do 1 A","cmc":"0,0045 % + 0,08 mA"},{"name":"5 kHz do 10 kHz","range":"1 A do 3 A","cmc":"2,3 % + 2,1 mA"},{"name":"5 kHz do 10 kHz","range":"3 A do 10 A","cmc":"2,3 % + 8,2 mA"}],"parameters_en":[{"name":"10 Hz to 2 kHz","range":"100 µA to 1 mA","cmc":"0,053 % + 0,4 µA"},{"name":"10 Hz to 2 kHz","range":"1 mA to 10 mA","cmc":"0,054 % + 4 µA"},{"name":"10 Hz to 2 kHz","range":"10 mA to 100 mA","cmc":"0,054 % 0,04 mA"},{"name":"10 Hz to 2 kHz","range":"100 mA to 1 A","cmc":"0,18 % 0,51 mA"},{"name":"10 Hz to 2 kHz","range":"1 A to 3 A","cmc":"0,14 % + 2,6 mA"},{"name":"10 Hz to 2 kHz","range":"3 A to 10 A","cmc":"0,38 % + 8,3 mA"},{"name":"2 kHz to 5 kHz","range":"100 µA to 1 mA","cmc":"0,066 % + 0,4 µA"},{"name":"2 kHz to 5 kHz","range":"1 mA to 10 mA","cmc":"0,066 % + 4 µA"},{"name":"2 kHz to 5 kHz","range":"10 mA to 100 mA","cmc":"0,066 % + 0,04 mA"},{"name":"2 kHz to 5 kHz","range":"100 mA to 1 A","cmc":"0,96 % + 0,51 mA"},{"name":"2 kHz to 5 kHz","range":"1 A to 3 A","cmc":"0,93 % + 2,6 mA"},{"name":"2 kHz to 5 kHz","range":"3 A to 10 A","cmc":"0,93 % + 8,2 mA"},{"name":"5 kHz to 10 kHz","range":"100 µA to 1 mA","cmc":"0,066 % + 0,4 µA"},{"name":"5 kHz to 10 kHz","range":"1 mA to 10 mA","cmc":"0,066 % + 4 µA"},{"name":"5 kHz to 10 kHz","range":"10 mA to 100 mA","cmc":"0,0045 % + 8 µA"},{"name":"5 kHz to 10 kHz","range":"100 mA to 1 A","cmc":"0,0045 % + 0,08 mA"},{"name":"5 kHz to 10 kHz","range":"1 A to 3 A","cmc":"2,3 % + 2,1 mA"},{"name":"5 kHz to 10 kHz","range":"3 A to 10 A","cmc":"2,3 % + 8,2 mA"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 2 kHz 100 µA do 1 mA CMC 0,053 % + 0,4 µA\n10 Hz do 2 kHz 1 mA do 10 mA CMC 0,054 % + 4 µA\n10 Hz do 2 kHz 10 mA do 100 mA CMC 0,054 % 0,04 mA\n10 Hz do 2 kHz 100 mA do 1 A CMC 0,18 % 0,51 mA\n10 Hz do 2 kHz 1 A do 3 A CMC 0,14 % + 2,6 mA\n10 Hz do 2 kHz 3 A do 10 A CMC 0,38 % + 8,3 mA\n2 kHz do 5 kHz 100 µA do 1 mA CMC 0,066 % + 0,4 µA\n2 kHz do 5 kHz 1 mA do 10 mA CMC 0,066 % + 4 µA\n2 kHz do 5 kHz 10 mA do 100 mA CMC 0,066 % + 0,04 mA\n2 kHz do 5 kHz 100 mA do 1 A CMC 0,96 % + 0,51 mA\n2 kHz do 5 kHz 1 A do 3 A CMC 0,93 % + 2,6 mA\n2 kHz do 5 kHz 3 A do 10 A CMC 0,93 % + 8,2 mA\n5 kHz do 10 kHz 100 µA do 1 mA CMC 0,066 % + 0,4 µA\n5 kHz do 10 kHz 1 mA do 10 mA CMC 0,066 % + 4 µA\n5 kHz do 10 kHz 10 mA do 100 mA CMC 0,0045 % + 8 µA\n5 kHz do 10 kHz 100 mA do 1 A CMC 0,0045 % + 0,08 mA\n5 kHz do 10 kHz 1 A do 3 A CMC 2,3 % + 2,1 mA\n5 kHz do 10 kHz 3 A do 10 A CMC 2,3 % + 8,2 mA\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LME-04","norm_bases":["PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kalibratory Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 2 kHz 100 µA do 1 mA CMC 0,053 % + 0,4 µA\n10 Hz do 2 kHz 1 mA do 10 mA CMC 0,054 % + 4 µA\n10 Hz do 2 kHz 10 mA do 100 mA CMC 0,054 % 0,04 mA\n10 Hz do 2 kHz 100 mA do 1 A CMC 0,18 % 0,51 mA\n10 Hz do 2 kHz 1 A do 3 A CMC 0,14 % + 2,6 mA\n10 Hz do 2 kHz 3 A do 10 A CMC 0,38 % + 8,3 mA\n2 kHz do 5 kHz 100 µA do 1 mA CMC 0,066 % + 0,4 µA\n2 kHz do 5 kHz 1 mA do 10 mA CMC 0,066 % + 4 µA\n2 kHz do 5 kHz 10 mA do 100 mA CMC 0,066 % + 0,04 mA\n2 kHz do 5 kHz 100 mA do 1 A CMC 0,96 % + 0,51 mA\n2 kHz do 5 kHz 1 A do 3 A CMC 0,93 % + 2,6 mA\n2 kHz do 5 kHz 3 A do 10 A CMC 0,93 % + 8,2 mA\n5 kHz do 10 kHz 100 µA do 1 mA CMC 0,066 % + 0,4 µA\n5 kHz do 10 kHz 1 mA do 10 mA CMC 0,066 % + 4 µA\n5 kHz do 10 kHz 10 mA do 100 mA CMC 0,0045 % + 8 µA\n5 kHz do 10 kHz 100 mA do 1 A CMC 0,0045 % + 0,08 mA\n5 kHz do 10 kHz 1 A do 3 A CMC 2,3 % + 2,1 mA\n5 kHz do 10 kHz 3 A do 10 A CMC 2,3 % + 8,2 mA\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP-LME-04 Kalibratory Wzorcowanie — Prad AC\nZakres:\n10 Hz do 2 kHz 100 µA do 1 mA CMC 0,053 % + 0,4 µA\n10 Hz do 2 kHz 1 mA do 10 mA CMC 0,054 % + 4 µA\n10 Hz do 2 kHz 10 mA do 100 mA CMC 0,054 % 0,04 mA\n10 Hz do 2 kHz 100 mA do 1 A CMC 0,18 % 0,51 mA\n10 Hz do 2 kHz 1 A do 3 A CMC 0,14 % + 2,6 mA\n10 Hz do 2 kHz 3 A do 10 A CMC 0,38 % + 8,3 mA\n2 kHz do 5 kHz 100 µA do 1 mA CMC 0,066 % + 0,4 µA\n2 kHz do 5 kHz 1 mA do 10 mA CMC 0,066 % + 4 µA\n2 kHz do 5 kHz 10 mA do 100 mA CMC 0,066 % + 0,04 mA\n2 kHz do 5 kHz 100 mA do 1 A CMC 0,96 % + 0,51 mA\n2 kHz do 5 kHz 1 A do 3 A CMC 0,93 % + 2,6 mA\n2 kHz do 5 kHz 3 A do 10 A CMC 0,93 % + 8,2 mA\n5 kHz do 10 kHz 100 µA do 1 mA CMC 0,066 % + 0,4 µA\n5 kHz do 10 kHz 1 mA do 10 mA CMC 0,066 % + 4 µA\n5 kHz do 10 kHz 10 mA do 100 mA CMC 0,0045 % + 8 µA\n5 kHz do 10 kHz 100 mA do 1 A CMC 0,0045 % + 0,08 mA\n5 kHz do 10 kHz 1 A do 3 A CMC 2,3 % + 2,1 mA\n5 kHz do 10 kHz 3 A do 10 A CMC 2,3 % + 8,2 mA\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP-LME-04","search_en":"Calibrators Calibration — AC current Internal procedure; At permanent location (S) AC current Internal procedure At permanent location (S) 10 Hz to 2 kHz 10 Hz to 2 kHz 10 Hz to 2 kHz 10 Hz to 2 kHz 10 Hz to 2 kHz 10 Hz to 2 kHz 2 kHz to 5 kHz 2 kHz to 5 kHz 2 kHz to 5 kHz 2 kHz to 5 kHz 2 kHz to 5 kHz 2 kHz to 5 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz Internal procedure PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":30,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LME-04","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"10 Hz bis 2 kHz","range":"100 µA to 1 mA","cmc":"0,053 % + 0,4 µA"},{"name":"10 Hz bis 2 kHz","range":"1 mA to 10 mA","cmc":"0,054 % + 4 µA"},{"name":"10 Hz bis 2 kHz","range":"10 mA bis 100 mA","cmc":"0,054 % 0,04 mA"},{"name":"10 Hz bis 2 kHz","range":"100 mA to 1 A","cmc":"0,18 % 0,51 mA"},{"name":"10 Hz bis 2 kHz","range":"1 A to 3 A","cmc":"0,14 % + 2,6 mA"},{"name":"10 Hz bis 2 kHz","range":"3 A to 10 A","cmc":"0,38 % + 8,3 mA"},{"name":"2 kHz bis 5 kHz","range":"100 µA to 1 mA","cmc":"0,066 % + 0,4 µA"},{"name":"2 kHz bis 5 kHz","range":"1 mA to 10 mA","cmc":"0,066 % + 4 µA"},{"name":"2 kHz bis 5 kHz","range":"10 mA bis 100 mA","cmc":"0,066 % + 0,04 mA"},{"name":"2 kHz bis 5 kHz","range":"100 mA to 1 A","cmc":"0,96 % + 0,51 mA"},{"name":"2 kHz bis 5 kHz","range":"1 A to 3 A","cmc":"0,93 % + 2,6 mA"},{"name":"2 kHz bis 5 kHz","range":"3 A to 10 A","cmc":"0,93 % + 8,2 mA"},{"name":"5 kHz bis 10 kHz","range":"100 µA to 1 mA","cmc":"0,066 % + 0,4 µA"},{"name":"5 kHz bis 10 kHz","range":"1 mA to 10 mA","cmc":"0,066 % + 4 µA"},{"name":"5 kHz bis 10 kHz","range":"10 mA bis 100 mA","cmc":"0,0045 % + 8 µA"},{"name":"5 kHz bis 10 kHz","range":"100 mA to 1 A","cmc":"0,0045 % + 0,08 mA"},{"name":"5 kHz bis 10 kHz","range":"1 A to 3 A","cmc":"2,3 % + 2,1 mA"},{"name":"5 kHz bis 10 kHz","range":"3 A to 10 A","cmc":"2,3 % + 8,2 mA"}],"reference_de":"Internes Verfahren PP-LME-04","regulatory_area_de":"AC-Strom","search_de":"Kalibratoren Kalibrierung — Wechselstrom Internes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Am festen Standort (S) 10 Hz bis 2 kHz 10 Hz bis 2 kHz 10 Hz bis 2 kHz 10 Hz bis 2 kHz 10 Hz bis 2 kHz 10 Hz bis 2 kHz 2 kHz bis 5 kHz 2 kHz bis 5 kHz 2 kHz bis 5 kHz 2 kHz bis 5 kHz 2 kHz bis 5 kHz 2 kHz bis 5 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz Internes Verfahren PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"10 Hz 至 2 kHz","range":"100 µA to 1 mA","cmc":"0,053 % + 0,4 µA"},{"name":"10 Hz 至 2 kHz","range":"1 mA to 10 mA","cmc":"0,054 % + 4 µA"},{"name":"10 Hz 至 2 kHz","range":"10 mA to 100 mA","cmc":"0,054 % 0,04 mA"},{"name":"10 Hz 至 2 kHz","range":"100 mA to 1 A","cmc":"0,18 % 0,51 mA"},{"name":"10 Hz 至 2 kHz","range":"1 A to 3 A","cmc":"0,14 % + 2,6 mA"},{"name":"10 Hz 至 2 kHz","range":"3 A to 10 A","cmc":"0,38 % + 8,3 mA"},{"name":"2 kHz 至 5 kHz","range":"100 µA to 1 mA","cmc":"0,066 % + 0,4 µA"},{"name":"2 kHz 至 5 kHz","range":"1 mA to 10 mA","cmc":"0,066 % + 4 µA"},{"name":"2 kHz 至 5 kHz","range":"10 mA to 100 mA","cmc":"0,066 % + 0,04 mA"},{"name":"2 kHz 至 5 kHz","range":"100 mA to 1 A","cmc":"0,96 % + 0,51 mA"},{"name":"2 kHz 至 5 kHz","range":"1 A to 3 A","cmc":"0,93 % + 2,6 mA"},{"name":"2 kHz 至 5 kHz","range":"3 A to 10 A","cmc":"0,93 % + 8,2 mA"},{"name":"5 kHz 至 10 kHz","range":"100 µA to 1 mA","cmc":"0,066 % + 0,4 µA"},{"name":"5 kHz 至 10 kHz","range":"1 mA to 10 mA","cmc":"0,066 % + 4 µA"},{"name":"5 kHz 至 10 kHz","range":"10 mA to 100 mA","cmc":"0,0045 % + 8 µA"},{"name":"5 kHz 至 10 kHz","range":"100 mA to 1 A","cmc":"0,0045 % + 0,08 mA"},{"name":"5 kHz 至 10 kHz","range":"1 A to 3 A","cmc":"2,3 % + 2,1 mA"},{"name":"5 kHz 至 10 kHz","range":"3 A to 10 A","cmc":"2,3 % + 8,2 mA"}],"reference_zh":"内部程序 PP-LME-04","regulatory_area_zh":"交流电流","search_zh":"校准器 校准 — 交流电流 内部程序；在固定地点 (S) 交流电流 内部程序 在固定地点 (S) 10 Hz 至 2 kHz 10 Hz 至 2 kHz 10 Hz 至 2 kHz 10 Hz 至 2 kHz 10 Hz 至 2 kHz 10 Hz 至 2 kHz 2 kHz 至 5 kHz 2 kHz 至 5 kHz 2 kHz 至 5 kHz 2 kHz 至 5 kHz 2 kHz 至 5 kHz 2 kHz 至 5 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 内部程序 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"10 Hz až 2 kHz","range":"100 µA to 1 mA","cmc":"0,053 % + 0,4 µA"},{"name":"10 Hz až 2 kHz","range":"1 mA to 10 mA","cmc":"0,054 % + 4 µA"},{"name":"10 Hz až 2 kHz","range":"10 mA to 100 mA","cmc":"0,054 % 0,04 mA"},{"name":"10 Hz až 2 kHz","range":"100 mA to 1 A","cmc":"0,18 % 0,51 mA"},{"name":"10 Hz až 2 kHz","range":"1 A to 3 A","cmc":"0,14 % + 2,6 mA"},{"name":"10 Hz až 2 kHz","range":"3 A to 10 A","cmc":"0,38 % + 8,3 mA"},{"name":"2 kHz až 5 kHz","range":"100 µA to 1 mA","cmc":"0,066 % + 0,4 µA"},{"name":"2 kHz až 5 kHz","range":"1 mA to 10 mA","cmc":"0,066 % + 4 µA"},{"name":"2 kHz až 5 kHz","range":"10 mA to 100 mA","cmc":"0,066 % + 0,04 mA"},{"name":"2 kHz až 5 kHz","range":"100 mA to 1 A","cmc":"0,96 % + 0,51 mA"},{"name":"2 kHz až 5 kHz","range":"1 A to 3 A","cmc":"0,93 % + 2,6 mA"},{"name":"2 kHz až 5 kHz","range":"3 A to 10 A","cmc":"0,93 % + 8,2 mA"},{"name":"5 kHz až 10 kHz","range":"100 µA to 1 mA","cmc":"0,066 % + 0,4 µA"},{"name":"5 kHz až 10 kHz","range":"1 mA to 10 mA","cmc":"0,066 % + 4 µA"},{"name":"5 kHz až 10 kHz","range":"10 mA to 100 mA","cmc":"0,0045 % + 8 µA"},{"name":"5 kHz až 10 kHz","range":"100 mA to 1 A","cmc":"0,0045 % + 0,08 mA"},{"name":"5 kHz až 10 kHz","range":"1 A to 3 A","cmc":"2,3 % + 2,1 mA"},{"name":"5 kHz až 10 kHz","range":"3 A to 10 A","cmc":"2,3 % + 8,2 mA"}],"reference_cs":"Vnitřní postup PP-LME-04","regulatory_area_cs":"Proud AC","search_cs":"Kalibrátory Kalibrace — Proud AC Vnitřní postup; Ve stálé lokalitě (S) Proud AC Vnitřní postup Ve stálé lokalitě (S) 10 Hz až 2 kHz 10 Hz až 2 kHz 10 Hz až 2 kHz 10 Hz až 2 kHz 10 Hz až 2 kHz 10 Hz až 2 kHz 2 kHz až 5 kHz 2 kHz až 5 kHz 2 kHz až 5 kHz 2 kHz až 5 kHz 2 kHz až 5 kHz 2 kHz až 5 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz Vnitřní postup PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory"},{"_id":"0be0657e83e10cb1d346b5e8","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"40 Hz do 1 kHz","range":"1 µA do 220 µA","cmc":"0,01 % + 0,008 µA"},{"name":"40 Hz do 1 kHz","range":"220 µA do 2,2 mA","cmc":"0,0091 % + 0,06 µA"},{"name":"40 Hz do 1 kHz","range":"2,2 mA do 22 mA","cmc":"0,01 % + 0,35 µA"},{"name":"40 Hz do 1 kHz","range":"22 mA do 220 mA","cmc":"0,01 % + 2,4 µA"},{"name":"40 Hz do 1 kHz","range":"220 mA do 2,2 A","cmc":"0,024 % + 0,04 mA"},{"name":"1 kHz do 5 kHz","range":"1 µA do 220 µA","cmc":"0,028 % + 0,012 µA"},{"name":"1 kHz do 5 kHz","range":"220 µA do 2,2 mA","cmc":"0,02 % + 0,12 µA"},{"name":"1 kHz do 5 kHz","range":"2,2 mA do 22 mA","cmc":"0,02 % + 0,55 µA"},{"name":"1 kHz do 5 kHz","range":"22 mA do 220 mA","cmc":"0,02 % + 3,6 µA"},{"name":"1 kHz do 5 kHz","range":"220 mA do 2,2 A","cmc":"0,045 % + 0,08 mA"},{"name":"10 Hz do 850 Hz","range":"2,2 A do 20 A","cmc":"0,009 % + 0,5 mA"},{"name":"10 Hz do 850 Hz","range":"20 A do 120 A","cmc":"0,009 % + 2,4 mA"},{"name":"850 Hz do 5 kHz","range":"2,2 A do 20 A","cmc":"0,04 % + 0,84 mA"},{"name":"850 Hz do 5 kHz","range":"20 A do 120 A","cmc":"0,04 % + 4,8 mA"},{"name":"10 Hz do 300 Hz","range":"120 A do 500 A","cmc":"0,7 % + 0,14 A"},{"name":"10 Hz do 300 Hz","range":"500 A do 3000 A","cmc":"0,7 % + 0,84 A"},{"name":"300 Hz do 1 kHz","range":"120 A do 500 A","cmc":"0,7 % + 0,14 A"},{"name":"300 Hz do 1 kHz","range":"500 A do 1000 A","cmc":"0,7 % + 0,84 A"},{"name":"1 kHz do 3 kHz","range":"120 A do 300 A","cmc":"0,8 % + 0,2 A"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"1 µA to 220 µA","cmc":"0,01 % + 0,008 µA"},{"name":"40 Hz to 1 kHz","range":"220 µA to 2,2 mA","cmc":"0,0091 % + 0,06 µA"},{"name":"40 Hz to 1 kHz","range":"2,2 mA to 22 mA","cmc":"0,01 % + 0,35 µA"},{"name":"40 Hz to 1 kHz","range":"22 mA to 220 mA","cmc":"0,01 % + 2,4 µA"},{"name":"40 Hz to 1 kHz","range":"220 mA to 2,2 A","cmc":"0,024 % + 0,04 mA"},{"name":"1 kHz to 5 kHz","range":"1 µA to 220 µA","cmc":"0,028 % + 0,012 µA"},{"name":"1 kHz to 5 kHz","range":"220 µA to 2,2 mA","cmc":"0,02 % + 0,12 µA"},{"name":"1 kHz to 5 kHz","range":"2,2 mA to 22 mA","cmc":"0,02 % + 0,55 µA"},{"name":"1 kHz to 5 kHz","range":"22 mA to 220 mA","cmc":"0,02 % + 3,6 µA"},{"name":"1 kHz to 5 kHz","range":"220 mA to 2,2 A","cmc":"0,045 % + 0,08 mA"},{"name":"10 Hz to 850 Hz","range":"2,2 A to 20 A","cmc":"0,009 % + 0,5 mA"},{"name":"10 Hz to 850 Hz","range":"20 A to 120 A","cmc":"0,009 % + 2,4 mA"},{"name":"850 Hz to 5 kHz","range":"2,2 A to 20 A","cmc":"0,04 % + 0,84 mA"},{"name":"850 Hz to 5 kHz","range":"20 A to 120 A","cmc":"0,04 % + 4,8 mA"},{"name":"10 Hz to 300 Hz","range":"120 A to 500 A","cmc":"0,7 % + 0,14 A"},{"name":"10 Hz to 300 Hz","range":"500 A to 3000 A","cmc":"0,7 % + 0,84 A"},{"name":"300 Hz to 1 kHz","range":"120 A to 500 A","cmc":"0,7 % + 0,14 A"},{"name":"300 Hz to 1 kHz","range":"500 A to 1000 A","cmc":"0,7 % + 0,84 A"},{"name":"1 kHz to 3 kHz","range":"120 A to 300 A","cmc":"0,8 % + 0,2 A"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 1 kHz 1 µA do 220 µA CMC 0,01 % + 0,008 µA\n40 Hz do 1 kHz 220 µA do 2,2 mA CMC 0,0091 % + 0,06 µA\n40 Hz do 1 kHz 2,2 mA do 22 mA CMC 0,01 % + 0,35 µA\n40 Hz do 1 kHz 22 mA do 220 mA CMC 0,01 % + 2,4 µA\n40 Hz do 1 kHz 220 mA do 2,2 A CMC 0,024 % + 0,04 mA\n1 kHz do 5 kHz 1 µA do 220 µA CMC 0,028 % + 0,012 µA\n1 kHz do 5 kHz 220 µA do 2,2 mA CMC 0,02 % + 0,12 µA\n1 kHz do 5 kHz 2,2 mA do 22 mA CMC 0,02 % + 0,55 µA\n1 kHz do 5 kHz 22 mA do 220 mA CMC 0,02 % + 3,6 µA\n1 kHz do 5 kHz 220 mA do 2,2 A CMC 0,045 % + 0,08 mA\n10 Hz do 850 Hz 2,2 A do 20 A CMC 0,009 % + 0,5 mA\n10 Hz do 850 Hz 20 A do 120 A CMC 0,009 % + 2,4 mA\n850 Hz do 5 kHz 2,2 A do 20 A CMC 0,04 % + 0,84 mA\n850 Hz do 5 kHz 20 A do 120 A CMC 0,04 % + 4,8 mA\n10 Hz do 300 Hz 120 A do 500 A CMC 0,7 % + 0,14 A\n10 Hz do 300 Hz 500 A do 3000 A CMC 0,7 % + 0,84 A\n300 Hz do 1 kHz 120 A do 500 A CMC 0,7 % + 0,14 A\n300 Hz do 1 kHz 500 A do 1000 A CMC 0,7 % + 0,84 A\n1 kHz do 3 kHz 120 A do 300 A CMC 0,8 % + 0,2 A\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LME-04","norm_bases":["PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki cęgowe Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 1 kHz 1 µA do 220 µA CMC 0,01 % + 0,008 µA\n40 Hz do 1 kHz 220 µA do 2,2 mA CMC 0,0091 % + 0,06 µA\n40 Hz do 1 kHz 2,2 mA do 22 mA CMC 0,01 % + 0,35 µA\n40 Hz do 1 kHz 22 mA do 220 mA CMC 0,01 % + 2,4 µA\n40 Hz do 1 kHz 220 mA do 2,2 A CMC 0,024 % + 0,04 mA\n1 kHz do 5 kHz 1 µA do 220 µA CMC 0,028 % + 0,012 µA\n1 kHz do 5 kHz 220 µA do 2,2 mA CMC 0,02 % + 0,12 µA\n1 kHz do 5 kHz 2,2 mA do 22 mA CMC 0,02 % + 0,55 µA\n1 kHz do 5 kHz 22 mA do 220 mA CMC 0,02 % + 3,6 µA\n1 kHz do 5 kHz 220 mA do 2,2 A CMC 0,045 % + 0,08 mA\n10 Hz do 850 Hz 2,2 A do 20 A CMC 0,009 % + 0,5 mA\n10 Hz do 850 Hz 20 A do 120 A CMC 0,009 % + 2,4 mA\n850 Hz do 5 kHz 2,2 A do 20 A CMC 0,04 % + 0,84 mA\n850 Hz do 5 kHz 20 A do 120 A CMC 0,04 % + 4,8 mA\n10 Hz do 300 Hz 120 A do 500 A CMC 0,7 % + 0,14 A\n10 Hz do 300 Hz 500 A do 3000 A CMC 0,7 % + 0,84 A\n300 Hz do 1 kHz 120 A do 500 A CMC 0,7 % + 0,14 A\n300 Hz do 1 kHz 500 A do 1000 A CMC 0,7 % + 0,84 A\n1 kHz do 3 kHz 120 A do 300 A CMC 0,8 % + 0,2 A\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP-LME-04 Mierniki cegowe Wzorcowanie — Prad AC\nZakres:\n40 Hz do 1 kHz 1 µA do 220 µA CMC 0,01 % + 0,008 µA\n40 Hz do 1 kHz 220 µA do 2,2 mA CMC 0,0091 % + 0,06 µA\n40 Hz do 1 kHz 2,2 mA do 22 mA CMC 0,01 % + 0,35 µA\n40 Hz do 1 kHz 22 mA do 220 mA CMC 0,01 % + 2,4 µA\n40 Hz do 1 kHz 220 mA do 2,2 A CMC 0,024 % + 0,04 mA\n1 kHz do 5 kHz 1 µA do 220 µA CMC 0,028 % + 0,012 µA\n1 kHz do 5 kHz 220 µA do 2,2 mA CMC 0,02 % + 0,12 µA\n1 kHz do 5 kHz 2,2 mA do 22 mA CMC 0,02 % + 0,55 µA\n1 kHz do 5 kHz 22 mA do 220 mA CMC 0,02 % + 3,6 µA\n1 kHz do 5 kHz 220 mA do 2,2 A CMC 0,045 % + 0,08 mA\n10 Hz do 850 Hz 2,2 A do 20 A CMC 0,009 % + 0,5 mA\n10 Hz do 850 Hz 20 A do 120 A CMC 0,009 % + 2,4 mA\n850 Hz do 5 kHz 2,2 A do 20 A CMC 0,04 % + 0,84 mA\n850 Hz do 5 kHz 20 A do 120 A CMC 0,04 % + 4,8 mA\n10 Hz do 300 Hz 120 A do 500 A CMC 0,7 % + 0,14 A\n10 Hz do 300 Hz 500 A do 3000 A CMC 0,7 % + 0,84 A\n300 Hz do 1 kHz 120 A do 500 A CMC 0,7 % + 0,14 A\n300 Hz do 1 kHz 500 A do 1000 A CMC 0,7 % + 0,84 A\n1 kHz do 3 kHz 120 A do 300 A CMC 0,8 % + 0,2 A\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP-LME-04","search_en":"Clamp meters Calibration — AC current Internal procedure; At permanent location (S) AC current Internal procedure At permanent location (S) 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 10 Hz to 850 Hz 10 Hz to 850 Hz 850 Hz to 5 kHz 850 Hz to 5 kHz 10 Hz to 300 Hz 10 Hz to 300 Hz 300 Hz to 1 kHz 300 Hz to 1 kHz 1 kHz to 3 kHz Internal procedure PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":31,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LME-04","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"40 Hz bis 1 kHz","range":"1 µA to 220 µA","cmc":"0,01 % + 0,008 µA"},{"name":"40 Hz bis 1 kHz","range":"220 µA to 2,2 mA","cmc":"0,0091 % + 0,06 µA"},{"name":"40 Hz bis 1 kHz","range":"2,2 mA to 22 mA","cmc":"0,01 % + 0,35 µA"},{"name":"40 Hz bis 1 kHz","range":"22 mA to 220 mA","cmc":"0,01 % + 2,4 µA"},{"name":"40 Hz bis 1 kHz","range":"220 mA to 2,2 A","cmc":"0,024 % + 0,04 mA"},{"name":"1 kHz bis 5 kHz","range":"1 µA to 220 µA","cmc":"0,028 % + 0,012 µA"},{"name":"1 kHz bis 5 kHz","range":"220 µA to 2,2 mA","cmc":"0,02 % + 0,12 µA"},{"name":"1 kHz bis 5 kHz","range":"2,2 mA to 22 mA","cmc":"0,02 % + 0,55 µA"},{"name":"1 kHz bis 5 kHz","range":"22 mA to 220 mA","cmc":"0,02 % + 3,6 µA"},{"name":"1 kHz bis 5 kHz","range":"220 mA to 2,2 A","cmc":"0,045 % + 0,08 mA"},{"name":"10 Hz bis 850 Hz","range":"2,2 A to 20 A","cmc":"0,009 % + 0,5 mA"},{"name":"10 Hz bis 850 Hz","range":"20 A to 120 A","cmc":"0,009 % + 2,4 mA"},{"name":"850 Hz bis 5 kHz","range":"2,2 A to 20 A","cmc":"0,04 % + 0,84 mA"},{"name":"850 Hz bis 5 kHz","range":"20 A to 120 A","cmc":"0,04 % + 4,8 mA"},{"name":"10 Hz bis 300 Hz","range":"120 A to 500 A","cmc":"0,7 % + 0,14 A"},{"name":"10 Hz bis 300 Hz","range":"500 A to 3000 A","cmc":"0,7 % + 0,84 A"},{"name":"300 Hz bis 1 kHz","range":"120 A to 500 A","cmc":"0,7 % + 0,14 A"},{"name":"300 Hz bis 1 kHz","range":"500 A to 1000 A","cmc":"0,7 % + 0,84 A"},{"name":"1 kHz bis 3 kHz","range":"120 A to 300 A","cmc":"0,8 % + 0,2 A"}],"reference_de":"Internes Verfahren PP-LME-04","regulatory_area_de":"AC-Strom","search_de":"Zangenmessgeräte Kalibrierung — Wechselstrom Internes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Am festen Standort (S) 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 10 Hz bis 850 Hz 10 Hz bis 850 Hz 850 Hz bis 5 kHz 850 Hz bis 5 kHz 10 Hz bis 300 Hz 10 Hz bis 300 Hz 300 Hz bis 1 kHz 300 Hz bis 1 kHz 1 kHz bis 3 kHz Internes Verfahren PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"1 µA to 220 µA","cmc":"0,01 % + 0,008 µA"},{"name":"40 Hz 至 1 kHz","range":"220 µA to 2,2 mA","cmc":"0,0091 % + 0,06 µA"},{"name":"40 Hz 至 1 kHz","range":"2,2 mA to 22 mA","cmc":"0,01 % + 0,35 µA"},{"name":"40 Hz 至 1 kHz","range":"22 mA to 220 mA","cmc":"0,01 % + 2,4 µA"},{"name":"40 Hz 至 1 kHz","range":"220 mA to 2,2 A","cmc":"0,024 % + 0,04 mA"},{"name":"1 kHz 至 5 kHz","range":"1 µA to 220 µA","cmc":"0,028 % + 0,012 µA"},{"name":"1 kHz 至 5 kHz","range":"220 µA to 2,2 mA","cmc":"0,02 % + 0,12 µA"},{"name":"1 kHz 至 5 kHz","range":"2,2 mA to 22 mA","cmc":"0,02 % + 0,55 µA"},{"name":"1 kHz 至 5 kHz","range":"22 mA to 220 mA","cmc":"0,02 % + 3,6 µA"},{"name":"1 kHz 至 5 kHz","range":"220 mA to 2,2 A","cmc":"0,045 % + 0,08 mA"},{"name":"10 Hz 至 850 Hz","range":"2,2 A to 20 A","cmc":"0,009 % + 0,5 mA"},{"name":"10 Hz 至 850 Hz","range":"20 A to 120 A","cmc":"0,009 % + 2,4 mA"},{"name":"850 Hz 至 5 kHz","range":"2,2 A to 20 A","cmc":"0,04 % + 0,84 mA"},{"name":"850 Hz 至 5 kHz","range":"20 A to 120 A","cmc":"0,04 % + 4,8 mA"},{"name":"10 Hz 至 300 Hz","range":"120 A to 500 A","cmc":"0,7 % + 0,14 A"},{"name":"10 Hz 至 300 Hz","range":"500 A to 3000 A","cmc":"0,7 % + 0,84 A"},{"name":"300 Hz 至 1 kHz","range":"120 A to 500 A","cmc":"0,7 % + 0,14 A"},{"name":"300 Hz 至 1 kHz","range":"500 A to 1000 A","cmc":"0,7 % + 0,84 A"},{"name":"1 kHz 至 3 kHz","range":"120 A to 300 A","cmc":"0,8 % + 0,2 A"}],"reference_zh":"内部程序 PP-LME-04","regulatory_area_zh":"交流电流","search_zh":"钳形表 校准 — 交流电流 内部程序；在固定地点 (S) 交流电流 内部程序 在固定地点 (S) 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 10 Hz 至 850 Hz 10 Hz 至 850 Hz 850 Hz 至 5 kHz 850 Hz 至 5 kHz 10 Hz 至 300 Hz 10 Hz 至 300 Hz 300 Hz 至 1 kHz 300 Hz 至 1 kHz 1 kHz 至 3 kHz 内部程序 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"40 Hz až 1 kHz","range":"1 µA to 220 µA","cmc":"0,01 % + 0,008 µA"},{"name":"40 Hz až 1 kHz","range":"220 µA to 2,2 mA","cmc":"0,0091 % + 0,06 µA"},{"name":"40 Hz až 1 kHz","range":"2,2 mA to 22 mA","cmc":"0,01 % + 0,35 µA"},{"name":"40 Hz až 1 kHz","range":"22 mA to 220 mA","cmc":"0,01 % + 2,4 µA"},{"name":"40 Hz až 1 kHz","range":"220 mA to 2,2 A","cmc":"0,024 % + 0,04 mA"},{"name":"1 kHz až 5 kHz","range":"1 µA to 220 µA","cmc":"0,028 % + 0,012 µA"},{"name":"1 kHz až 5 kHz","range":"220 µA to 2,2 mA","cmc":"0,02 % + 0,12 µA"},{"name":"1 kHz až 5 kHz","range":"2,2 mA to 22 mA","cmc":"0,02 % + 0,55 µA"},{"name":"1 kHz až 5 kHz","range":"22 mA to 220 mA","cmc":"0,02 % + 3,6 µA"},{"name":"1 kHz až 5 kHz","range":"220 mA to 2,2 A","cmc":"0,045 % + 0,08 mA"},{"name":"10 Hz až 850 Hz","range":"2,2 A to 20 A","cmc":"0,009 % + 0,5 mA"},{"name":"10 Hz až 850 Hz","range":"20 A to 120 A","cmc":"0,009 % + 2,4 mA"},{"name":"850 Hz až 5 kHz","range":"2,2 A to 20 A","cmc":"0,04 % + 0,84 mA"},{"name":"850 Hz až 5 kHz","range":"20 A to 120 A","cmc":"0,04 % + 4,8 mA"},{"name":"10 Hz až 300 Hz","range":"120 A to 500 A","cmc":"0,7 % + 0,14 A"},{"name":"10 Hz až 300 Hz","range":"500 A to 3000 A","cmc":"0,7 % + 0,84 A"},{"name":"300 Hz až 1 kHz","range":"120 A to 500 A","cmc":"0,7 % + 0,14 A"},{"name":"300 Hz až 1 kHz","range":"500 A to 1000 A","cmc":"0,7 % + 0,84 A"},{"name":"1 kHz až 3 kHz","range":"120 A to 300 A","cmc":"0,8 % + 0,2 A"}],"reference_cs":"Vnitřní postup PP-LME-04","regulatory_area_cs":"Proud AC","search_cs":"Klešťové měřiče Kalibrace — Proud AC Vnitřní postup; Ve stálé lokalitě (S) Proud AC Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 10 Hz až 850 Hz 10 Hz až 850 Hz 850 Hz až 5 kHz 850 Hz až 5 kHz 10 Hz až 300 Hz 10 Hz až 300 Hz 300 Hz až 1 kHz 300 Hz až 1 kHz 1 kHz až 3 kHz Vnitřní postup PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Klešťové měřiče"},{"_id":"948f63e5197c3b5aa70a2432","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Mierniki prądu analogowe i cyfrowe\nMultimetry","test_object_en":"Analogue and digital ammeters\nMultimeters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"40 Hz do 1 kHz","range":"1 µA do 220 µA","cmc":"0,01 % + 0,008 µA"},{"name":"40 Hz do 1 kHz","range":"220 µA do 2,2 mA","cmc":"0,0091 % + 0,06 µA"},{"name":"40 Hz do 1 kHz","range":"2,2 mA do 22 mA","cmc":"0,01 % + 0,35 µA"},{"name":"40 Hz do 1 kHz","range":"22 mA do 220 mA","cmc":"0,01 % + 2,4 µA"},{"name":"40 Hz do 1 kHz","range":"220 mA do 2,2 A","cmc":"0,024 % + 0,04 mA"},{"name":"1 kHz do 5 kHz","range":"1 µA do 220 µA","cmc":"0,028 % + 0,012 µA"},{"name":"1 kHz do 5 kHz","range":"220 µA do 2,2 mA","cmc":"0,02 % + 0,12 µA"},{"name":"1 kHz do 5 kHz","range":"2,2 mA do 22 mA","cmc":"0,02 % + 0,55 µA"},{"name":"1 kHz do 5 kHz","range":"22 mA do 220 mA","cmc":"0,02 % + 3,6 µA"},{"name":"1 kHz do 5 kHz","range":"220 mA do 2,2 A","cmc":"0,045 % + 0,08 mA"},{"name":"10 Hz do 850 Hz","range":"2,2 A do 20 A","cmc":"0,009 % + 0,5 mA"},{"name":"10 Hz do 850 Hz","range":"20 A do 120 A","cmc":"0,009 % + 2,4 mA"},{"name":"850 Hz do 5 kHz","range":"2,2 A do 20 A","cmc":"0,04 % + 0,84 mA"},{"name":"850 Hz do 5 kHz","range":"20 A do 120 A","cmc":"0,04 % + 4,8 mA"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"1 µA to 220 µA","cmc":"0,01 % + 0,008 µA"},{"name":"40 Hz to 1 kHz","range":"220 µA to 2,2 mA","cmc":"0,0091 % + 0,06 µA"},{"name":"40 Hz to 1 kHz","range":"2,2 mA to 22 mA","cmc":"0,01 % + 0,35 µA"},{"name":"40 Hz to 1 kHz","range":"22 mA to 220 mA","cmc":"0,01 % + 2,4 µA"},{"name":"40 Hz to 1 kHz","range":"220 mA to 2,2 A","cmc":"0,024 % + 0,04 mA"},{"name":"1 kHz to 5 kHz","range":"1 µA to 220 µA","cmc":"0,028 % + 0,012 µA"},{"name":"1 kHz to 5 kHz","range":"220 µA to 2,2 mA","cmc":"0,02 % + 0,12 µA"},{"name":"1 kHz to 5 kHz","range":"2,2 mA to 22 mA","cmc":"0,02 % + 0,55 µA"},{"name":"1 kHz to 5 kHz","range":"22 mA to 220 mA","cmc":"0,02 % + 3,6 µA"},{"name":"1 kHz to 5 kHz","range":"220 mA to 2,2 A","cmc":"0,045 % + 0,08 mA"},{"name":"10 Hz to 850 Hz","range":"2,2 A to 20 A","cmc":"0,009 % + 0,5 mA"},{"name":"10 Hz to 850 Hz","range":"20 A to 120 A","cmc":"0,009 % + 2,4 mA"},{"name":"850 Hz to 5 kHz","range":"2,2 A to 20 A","cmc":"0,04 % + 0,84 mA"},{"name":"850 Hz to 5 kHz","range":"20 A to 120 A","cmc":"0,04 % + 4,8 mA"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 1 kHz 1 µA do 220 µA CMC 0,01 % + 0,008 µA\n40 Hz do 1 kHz 220 µA do 2,2 mA CMC 0,0091 % + 0,06 µA\n40 Hz do 1 kHz 2,2 mA do 22 mA CMC 0,01 % + 0,35 µA\n40 Hz do 1 kHz 22 mA do 220 mA CMC 0,01 % + 2,4 µA\n40 Hz do 1 kHz 220 mA do 2,2 A CMC 0,024 % + 0,04 mA\n1 kHz do 5 kHz 1 µA do 220 µA CMC 0,028 % + 0,012 µA\n1 kHz do 5 kHz 220 µA do 2,2 mA CMC 0,02 % + 0,12 µA\n1 kHz do 5 kHz 2,2 mA do 22 mA CMC 0,02 % + 0,55 µA\n1 kHz do 5 kHz 22 mA do 220 mA CMC 0,02 % + 3,6 µA\n1 kHz do 5 kHz 220 mA do 2,2 A CMC 0,045 % + 0,08 mA\n10 Hz do 850 Hz 2,2 A do 20 A CMC 0,009 % + 0,5 mA\n10 Hz do 850 Hz 20 A do 120 A CMC 0,009 % + 2,4 mA\n850 Hz do 5 kHz 2,2 A do 20 A CMC 0,04 % + 0,84 mA\n850 Hz do 5 kHz 20 A do 120 A CMC 0,04 % + 4,8 mA\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedury wewnętrzne PP-LME-03 PP-LME-04","norm_bases":["PP-LME-03","PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki prądu analogowe i cyfrowe\nMultimetry Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 1 kHz 1 µA do 220 µA CMC 0,01 % + 0,008 µA\n40 Hz do 1 kHz 220 µA do 2,2 mA CMC 0,0091 % + 0,06 µA\n40 Hz do 1 kHz 2,2 mA do 22 mA CMC 0,01 % + 0,35 µA\n40 Hz do 1 kHz 22 mA do 220 mA CMC 0,01 % + 2,4 µA\n40 Hz do 1 kHz 220 mA do 2,2 A CMC 0,024 % + 0,04 mA\n1 kHz do 5 kHz 1 µA do 220 µA CMC 0,028 % + 0,012 µA\n1 kHz do 5 kHz 220 µA do 2,2 mA CMC 0,02 % + 0,12 µA\n1 kHz do 5 kHz 2,2 mA do 22 mA CMC 0,02 % + 0,55 µA\n1 kHz do 5 kHz 22 mA do 220 mA CMC 0,02 % + 3,6 µA\n1 kHz do 5 kHz 220 mA do 2,2 A CMC 0,045 % + 0,08 mA\n10 Hz do 850 Hz 2,2 A do 20 A CMC 0,009 % + 0,5 mA\n10 Hz do 850 Hz 20 A do 120 A CMC 0,009 % + 2,4 mA\n850 Hz do 5 kHz 2,2 A do 20 A CMC 0,04 % + 0,84 mA\n850 Hz do 5 kHz 20 A do 120 A CMC 0,04 % + 4,8 mA\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedury wewnętrzne PP-LME-03 PP-LME-04 Mierniki pradu analogowe i cyfrowe\nMultimetry Wzorcowanie — Prad AC\nZakres:\n40 Hz do 1 kHz 1 µA do 220 µA CMC 0,01 % + 0,008 µA\n40 Hz do 1 kHz 220 µA do 2,2 mA CMC 0,0091 % + 0,06 µA\n40 Hz do 1 kHz 2,2 mA do 22 mA CMC 0,01 % + 0,35 µA\n40 Hz do 1 kHz 22 mA do 220 mA CMC 0,01 % + 2,4 µA\n40 Hz do 1 kHz 220 mA do 2,2 A CMC 0,024 % + 0,04 mA\n1 kHz do 5 kHz 1 µA do 220 µA CMC 0,028 % + 0,012 µA\n1 kHz do 5 kHz 220 µA do 2,2 mA CMC 0,02 % + 0,12 µA\n1 kHz do 5 kHz 2,2 mA do 22 mA CMC 0,02 % + 0,55 µA\n1 kHz do 5 kHz 22 mA do 220 mA CMC 0,02 % + 3,6 µA\n1 kHz do 5 kHz 220 mA do 2,2 A CMC 0,045 % + 0,08 mA\n10 Hz do 850 Hz 2,2 A do 20 A CMC 0,009 % + 0,5 mA\n10 Hz do 850 Hz 20 A do 120 A CMC 0,009 % + 2,4 mA\n850 Hz do 5 kHz 2,2 A do 20 A CMC 0,04 % + 0,84 mA\n850 Hz do 5 kHz 20 A do 120 A CMC 0,04 % + 4,8 mA\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedury wewnetrzne PP-LME-03 PP-LME-04","search_en":"Analogue and digital ammeters Multimeters Calibration — AC current Internal procedure; At permanent location (S) AC current Internal procedure At permanent location (S) 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 10 Hz to 850 Hz 10 Hz to 850 Hz 850 Hz to 5 kHz 850 Hz to 5 kHz Internal procedures PP-LME-03 PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":32,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedures PP-LME-03 PP-LME-04","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"40 Hz bis 1 kHz","range":"1 µA to 220 µA","cmc":"0,01 % + 0,008 µA"},{"name":"40 Hz bis 1 kHz","range":"220 µA to 2,2 mA","cmc":"0,0091 % + 0,06 µA"},{"name":"40 Hz bis 1 kHz","range":"2,2 mA to 22 mA","cmc":"0,01 % + 0,35 µA"},{"name":"40 Hz bis 1 kHz","range":"22 mA to 220 mA","cmc":"0,01 % + 2,4 µA"},{"name":"40 Hz bis 1 kHz","range":"220 mA to 2,2 A","cmc":"0,024 % + 0,04 mA"},{"name":"1 kHz bis 5 kHz","range":"1 µA to 220 µA","cmc":"0,028 % + 0,012 µA"},{"name":"1 kHz bis 5 kHz","range":"220 µA to 2,2 mA","cmc":"0,02 % + 0,12 µA"},{"name":"1 kHz bis 5 kHz","range":"2,2 mA to 22 mA","cmc":"0,02 % + 0,55 µA"},{"name":"1 kHz bis 5 kHz","range":"22 mA to 220 mA","cmc":"0,02 % + 3,6 µA"},{"name":"1 kHz bis 5 kHz","range":"220 mA to 2,2 A","cmc":"0,045 % + 0,08 mA"},{"name":"10 Hz bis 850 Hz","range":"2,2 A to 20 A","cmc":"0,009 % + 0,5 mA"},{"name":"10 Hz bis 850 Hz","range":"20 A to 120 A","cmc":"0,009 % + 2,4 mA"},{"name":"850 Hz bis 5 kHz","range":"2,2 A to 20 A","cmc":"0,04 % + 0,84 mA"},{"name":"850 Hz bis 5 kHz","range":"20 A to 120 A","cmc":"0,04 % + 4,8 mA"}],"reference_de":"Interne Verfahren PP-LME-03 PP-LME-04","regulatory_area_de":"AC-Strom","search_de":"Analoge und digitale Strommessgeräte Multimeter Kalibrierung — Wechselstrom Internes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Am festen Standort (S) 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 10 Hz bis 850 Hz 10 Hz bis 850 Hz 850 Hz bis 5 kHz 850 Hz bis 5 kHz Interne Verfahren PP-LME-03 PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge und digitale Strommessgeräte\nMultimeter","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"1 µA to 220 µA","cmc":"0,01 % + 0,008 µA"},{"name":"40 Hz 至 1 kHz","range":"220 µA to 2,2 mA","cmc":"0,0091 % + 0,06 µA"},{"name":"40 Hz 至 1 kHz","range":"2,2 mA to 22 mA","cmc":"0,01 % + 0,35 µA"},{"name":"40 Hz 至 1 kHz","range":"22 mA to 220 mA","cmc":"0,01 % + 2,4 µA"},{"name":"40 Hz 至 1 kHz","range":"220 mA to 2,2 A","cmc":"0,024 % + 0,04 mA"},{"name":"1 kHz 至 5 kHz","range":"1 µA to 220 µA","cmc":"0,028 % + 0,012 µA"},{"name":"1 kHz 至 5 kHz","range":"220 µA to 2,2 mA","cmc":"0,02 % + 0,12 µA"},{"name":"1 kHz 至 5 kHz","range":"2,2 mA to 22 mA","cmc":"0,02 % + 0,55 µA"},{"name":"1 kHz 至 5 kHz","range":"22 mA to 220 mA","cmc":"0,02 % + 3,6 µA"},{"name":"1 kHz 至 5 kHz","range":"220 mA to 2,2 A","cmc":"0,045 % + 0,08 mA"},{"name":"10 Hz 至 850 Hz","range":"2,2 A to 20 A","cmc":"0,009 % + 0,5 mA"},{"name":"10 Hz 至 850 Hz","range":"20 A to 120 A","cmc":"0,009 % + 2,4 mA"},{"name":"850 Hz 至 5 kHz","range":"2,2 A to 20 A","cmc":"0,04 % + 0,84 mA"},{"name":"850 Hz 至 5 kHz","range":"20 A to 120 A","cmc":"0,04 % + 4,8 mA"}],"reference_zh":"内部程序 PP-LME-03 PP-LME-04","regulatory_area_zh":"交流电流","search_zh":"模拟和数字电流表 万用表 校准 — 交流电流 内部程序；在固定地点 (S) 交流电流 内部程序 在固定地点 (S) 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 10 Hz 至 850 Hz 10 Hz 至 850 Hz 850 Hz 至 5 kHz 850 Hz 至 5 kHz 内部程序 PP-LME-03 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"模拟和数字电流表\n万用表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"40 Hz až 1 kHz","range":"1 µA to 220 µA","cmc":"0,01 % + 0,008 µA"},{"name":"40 Hz až 1 kHz","range":"220 µA to 2,2 mA","cmc":"0,0091 % + 0,06 µA"},{"name":"40 Hz až 1 kHz","range":"2,2 mA to 22 mA","cmc":"0,01 % + 0,35 µA"},{"name":"40 Hz až 1 kHz","range":"22 mA to 220 mA","cmc":"0,01 % + 2,4 µA"},{"name":"40 Hz až 1 kHz","range":"220 mA to 2,2 A","cmc":"0,024 % + 0,04 mA"},{"name":"1 kHz až 5 kHz","range":"1 µA to 220 µA","cmc":"0,028 % + 0,012 µA"},{"name":"1 kHz až 5 kHz","range":"220 µA to 2,2 mA","cmc":"0,02 % + 0,12 µA"},{"name":"1 kHz až 5 kHz","range":"2,2 mA to 22 mA","cmc":"0,02 % + 0,55 µA"},{"name":"1 kHz až 5 kHz","range":"22 mA to 220 mA","cmc":"0,02 % + 3,6 µA"},{"name":"1 kHz až 5 kHz","range":"220 mA to 2,2 A","cmc":"0,045 % + 0,08 mA"},{"name":"10 Hz až 850 Hz","range":"2,2 A to 20 A","cmc":"0,009 % + 0,5 mA"},{"name":"10 Hz až 850 Hz","range":"20 A to 120 A","cmc":"0,009 % + 2,4 mA"},{"name":"850 Hz až 5 kHz","range":"2,2 A to 20 A","cmc":"0,04 % + 0,84 mA"},{"name":"850 Hz až 5 kHz","range":"20 A to 120 A","cmc":"0,04 % + 4,8 mA"}],"reference_cs":"Interní postupy PP-LME-03 PP-LME-04","regulatory_area_cs":"Proud AC","search_cs":"Analogové a digitální měřiče proudu Multimetry Kalibrace — Proud AC Vnitřní postup; Ve stálé lokalitě (S) Proud AC Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 10 Hz až 850 Hz 10 Hz až 850 Hz 850 Hz až 5 kHz 850 Hz až 5 kHz Interní postupy PP-LME-03 PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové a digitální měřiče proudu\nMultimetry"},{"_id":"ff7c020d211eeeff67e035f1","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Boczniki\nRezystory stałe i regulowane","test_object_en":"Shunts\nFixed and variable resistors","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"1 µΩ do 100 µΩ","cmc":"0,2 µΩ"},{"name":"","range":"100 µΩ do 1 mΩ","cmc":"0,2 %"},{"name":"","range":"1 mΩ do 10 mΩ","cmc":"0,037 %"},{"name":"","range":"10 mΩ do 100 mΩ","cmc":"0,028 %"},{"name":"","range":"100 mΩ do 1 Ω","cmc":"0,065 %"},{"name":"","range":"1 Ω do 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω do 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω do 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ do 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"0,024 %"},{"name":"","range":"100 MΩ do 1 GΩ","cmc":"0,06 %"},{"name":"","range":"1 GΩ do 10 GΩ","cmc":"0,45 %"}],"parameters_en":[{"name":"","range":"1 µΩ to 100 µΩ","cmc":"0,2 µΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"0,2 %"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"0,037 %"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"0,028 %"},{"name":"","range":"100 mΩ to 1 Ω","cmc":"0,065 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,024 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,06 %"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,45 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n1 µΩ do 100 µΩ CMC 0,2 µΩ\n100 µΩ do 1 mΩ CMC 0,2 %\n1 mΩ do 10 mΩ CMC 0,037 %\n10 mΩ do 100 mΩ CMC 0,028 %\n100 mΩ do 1 Ω CMC 0,065 %\n1 Ω do 10 Ω CMC 0,0035 % + 0,06 mΩ\n10 Ω do 100 Ω CMC 0,0031 % + 0,46 mΩ\n100 Ω do 1 kΩ CMC 0,0024 % + 3,8 mΩ\n1 kΩ do 10 kΩ CMC 0,0031 % + 0,038 Ω\n10 kΩ do 100 kΩ CMC 0,0031 % + 0,39 Ω\n100 kΩ do 1 MΩ CMC 0,003 % + 5,1 Ω\n1 MΩ do 10 MΩ CMC 0,022 % + 0,13 kΩ\n10 MΩ do 100 MΩ CMC 0,024 %\n100 MΩ do 1 GΩ CMC 0,06 %\n1 GΩ do 10 GΩ CMC 0,45 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LME-01","norm_bases":["PP-LME-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Boczniki\nRezystory stałe i regulowane Wzorcowanie — Rezystancja DC\nZakres:\n1 µΩ do 100 µΩ CMC 0,2 µΩ\n100 µΩ do 1 mΩ CMC 0,2 %\n1 mΩ do 10 mΩ CMC 0,037 %\n10 mΩ do 100 mΩ CMC 0,028 %\n100 mΩ do 1 Ω CMC 0,065 %\n1 Ω do 10 Ω CMC 0,0035 % + 0,06 mΩ\n10 Ω do 100 Ω CMC 0,0031 % + 0,46 mΩ\n100 Ω do 1 kΩ CMC 0,0024 % + 3,8 mΩ\n1 kΩ do 10 kΩ CMC 0,0031 % + 0,038 Ω\n10 kΩ do 100 kΩ CMC 0,0031 % + 0,39 Ω\n100 kΩ do 1 MΩ CMC 0,003 % + 5,1 Ω\n1 MΩ do 10 MΩ CMC 0,022 % + 0,13 kΩ\n10 MΩ do 100 MΩ CMC 0,024 %\n100 MΩ do 1 GΩ CMC 0,06 %\n1 GΩ do 10 GΩ CMC 0,45 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP-LME-01 Boczniki\nRezystory stale i regulowane Wzorcowanie — Rezystancja DC\nZakres:\n1 µΩ do 100 µΩ CMC 0,2 µΩ\n100 µΩ do 1 mΩ CMC 0,2 %\n1 mΩ do 10 mΩ CMC 0,037 %\n10 mΩ do 100 mΩ CMC 0,028 %\n100 mΩ do 1 Ω CMC 0,065 %\n1 Ω do 10 Ω CMC 0,0035 % + 0,06 mΩ\n10 Ω do 100 Ω CMC 0,0031 % + 0,46 mΩ\n100 Ω do 1 kΩ CMC 0,0024 % + 3,8 mΩ\n1 kΩ do 10 kΩ CMC 0,0031 % + 0,038 Ω\n10 kΩ do 100 kΩ CMC 0,0031 % + 0,39 Ω\n100 kΩ do 1 MΩ CMC 0,003 % + 5,1 Ω\n1 MΩ do 10 MΩ CMC 0,022 % + 0,13 kΩ\n10 MΩ do 100 MΩ CMC 0,024 %\n100 MΩ do 1 GΩ CMC 0,06 %\n1 GΩ do 10 GΩ CMC 0,45 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP-LME-01","search_en":"Shunts Fixed and variable resistors Calibration — DC resistance Internal procedure; At permanent location (S) DC resistance Internal procedure At permanent location (S) Internal procedure PP-LME-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":33,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LME-01","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"1 µΩ to 100 µΩ","cmc":"0,2 µΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"0,2 %"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"0,037 %"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"0,028 %"},{"name":"","range":"100 mΩ to 1 Ω","cmc":"0,065 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,024 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,06 %"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,45 %"}],"reference_de":"Internes Verfahren PP-LME-01","regulatory_area_de":"DC-Widerstand","search_de":"Shunts Fest- und einstellbare Widerstände Kalibrierung — DC-Widerstand Internes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Am festen Standort (S) Internes Verfahren PP-LME-01","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Shunts\nFest- und einstellbare Widerstände","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"1 µΩ to 100 µΩ","cmc":"0,2 µΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"0,2 %"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"0,037 %"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"0,028 %"},{"name":"","range":"100 mΩ to 1 Ω","cmc":"0,065 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,024 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,06 %"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,45 %"}],"reference_zh":"内部程序 PP-LME-01","regulatory_area_zh":"直流电阻","search_zh":"分流器 固定和可调电阻器 校准 — 直流电阻 内部程序；在固定地点 (S) 直流电阻 内部程序 在固定地点 (S) 内部程序 PP-LME-01","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"分流器\n固定和可调电阻器","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"1 µΩ to 100 µΩ","cmc":"0,2 µΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"0,2 %"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"0,037 %"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"0,028 %"},{"name":"","range":"100 mΩ to 1 Ω","cmc":"0,065 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,024 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,06 %"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,45 %"}],"reference_cs":"Vnitřní postup PP-LME-01","regulatory_area_cs":"Odpor DC","search_cs":"Bočníky Pevné a nastavitelné rezistory Kalibrace — Odpor DC Vnitřní postup; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PP-LME-01","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Bočníky\nPevné a nastavitelné rezistory"},{"_id":"2b4b86023aa93cd7b1578b73","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Kalibratory","test_object_en":"Calibrators","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0,01 Ω do 1 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"1 Ω do 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω do 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω do 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ do 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"0,23 % + 3,9 kΩ"},{"name":"","range":"100 MΩ do 1 GΩ","cmc":"1,03 % + 0,13 MΩ"}],"parameters_en":[{"name":"","range":"0,01 Ω to 1 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,23 % + 3,9 kΩ"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"1,03 % + 0,13 MΩ"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0,01 Ω do 1 Ω CMC 0,0035 % + 0,06 mΩ\n1 Ω do 10 Ω CMC 0,0035 % + 0,06 mΩ\n10 Ω do 100 Ω CMC 0,0031 % + 0,46 mΩ\n100 Ω do 1 kΩ CMC 0,0024 % + 3,8 mΩ\n1 kΩ do 10 kΩ CMC 0,0031 % + 0,038 Ω\n10 kΩ do 100 kΩ CMC 0,0031 % + 0,39 Ω\n100 kΩ do 1 MΩ CMC 0,003 % + 5,1 Ω\n1 MΩ do 10 MΩ CMC 0,022 % + 0,13 kΩ\n10 MΩ do 100 MΩ CMC 0,23 % + 3,9 kΩ\n100 MΩ do 1 GΩ CMC 1,03 % + 0,13 MΩ\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LME-04","norm_bases":["PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kalibratory Wzorcowanie — Rezystancja DC\nZakres:\n0,01 Ω do 1 Ω CMC 0,0035 % + 0,06 mΩ\n1 Ω do 10 Ω CMC 0,0035 % + 0,06 mΩ\n10 Ω do 100 Ω CMC 0,0031 % + 0,46 mΩ\n100 Ω do 1 kΩ CMC 0,0024 % + 3,8 mΩ\n1 kΩ do 10 kΩ CMC 0,0031 % + 0,038 Ω\n10 kΩ do 100 kΩ CMC 0,0031 % + 0,39 Ω\n100 kΩ do 1 MΩ CMC 0,003 % + 5,1 Ω\n1 MΩ do 10 MΩ CMC 0,022 % + 0,13 kΩ\n10 MΩ do 100 MΩ CMC 0,23 % + 3,9 kΩ\n100 MΩ do 1 GΩ CMC 1,03 % + 0,13 MΩ\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP-LME-04 Kalibratory Wzorcowanie — Rezystancja DC\nZakres:\n0,01 Ω do 1 Ω CMC 0,0035 % + 0,06 mΩ\n1 Ω do 10 Ω CMC 0,0035 % + 0,06 mΩ\n10 Ω do 100 Ω CMC 0,0031 % + 0,46 mΩ\n100 Ω do 1 kΩ CMC 0,0024 % + 3,8 mΩ\n1 kΩ do 10 kΩ CMC 0,0031 % + 0,038 Ω\n10 kΩ do 100 kΩ CMC 0,0031 % + 0,39 Ω\n100 kΩ do 1 MΩ CMC 0,003 % + 5,1 Ω\n1 MΩ do 10 MΩ CMC 0,022 % + 0,13 kΩ\n10 MΩ do 100 MΩ CMC 0,23 % + 3,9 kΩ\n100 MΩ do 1 GΩ CMC 1,03 % + 0,13 MΩ\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP-LME-04","search_en":"Calibrators Calibration — DC resistance Internal procedure; At permanent location (S) DC resistance Internal procedure At permanent location (S) Internal procedure PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":34,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LME-04","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0,01 Ω to 1 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,23 % + 3,9 kΩ"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"1,03 % + 0,13 MΩ"}],"reference_de":"Internes Verfahren PP-LME-04","regulatory_area_de":"DC-Widerstand","search_de":"Kalibratoren Kalibrierung — DC-Widerstand Internes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Am festen Standort (S) Internes Verfahren PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0,01 Ω to 1 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,23 % + 3,9 kΩ"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"1,03 % + 0,13 MΩ"}],"reference_zh":"内部程序 PP-LME-04","regulatory_area_zh":"直流电阻","search_zh":"校准器 校准 — 直流电阻 内部程序；在固定地点 (S) 直流电阻 内部程序 在固定地点 (S) 内部程序 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0,01 Ω to 1 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,23 % + 3,9 kΩ"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"1,03 % + 0,13 MΩ"}],"reference_cs":"Vnitřní postup PP-LME-04","regulatory_area_cs":"Odpor DC","search_cs":"Kalibrátory Kalibrace — Odpor DC Vnitřní postup; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory"},{"_id":"f7ecc06df85b4fb47984c71b","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Mierniki rezystancji analogowe i cyfrowe\nMultimetry","test_object_en":"Analogue and digital ohmmeters\nMultimeters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"1 µΩ do 100 µΩ","cmc":"0,2 µΩ"},{"name":"","range":"100 µΩ do 1 mΩ","cmc":"0,2 %"},{"name":"","range":"1 mΩ do 10 mΩ","cmc":"0,037 %"},{"name":"","range":"10 mΩ do 100 mΩ","cmc":"0,028 %"},{"name":"","range":"100 mΩ do 1 Ω","cmc":"0,065 %"},{"name":"","range":"1 Ω do 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω do 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω do 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ do 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"0,024 %"},{"name":"","range":"100 MΩ do 1 GΩ","cmc":"0,06 %"},{"name":"","range":"1 GΩ do 10 GΩ","cmc":"0,12 %"},{"name":"","range":"10 GΩ do 100 GΩ","cmc":"0,5 %"}],"parameters_en":[{"name":"","range":"1 µΩ to 100 µΩ","cmc":"0,2 µΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"0,2 %"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"0,037 %"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"0,028 %"},{"name":"","range":"100 mΩ to 1 Ω","cmc":"0,065 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,024 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,06 %"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,12 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,5 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n1 µΩ do 100 µΩ CMC 0,2 µΩ\n100 µΩ do 1 mΩ CMC 0,2 %\n1 mΩ do 10 mΩ CMC 0,037 %\n10 mΩ do 100 mΩ CMC 0,028 %\n100 mΩ do 1 Ω CMC 0,065 %\n1 Ω do 10 Ω CMC 0,0035 % + 0,06 mΩ\n10 Ω do 100 Ω CMC 0,0031 % + 0,46 mΩ\n100 Ω do 1 kΩ CMC 0,0024 % + 3,8 mΩ\n1 kΩ do 10 kΩ CMC 0,0031 % + 0,038 Ω\n10 kΩ do 100 kΩ CMC 0,0031 % + 0,39 Ω\n100 kΩ do 1 MΩ CMC 0,003 % + 5,1 Ω\n1 MΩ do 10 MΩ CMC 0,022 % + 0,13 kΩ\n10 MΩ do 100 MΩ CMC 0,024 %\n100 MΩ do 1 GΩ CMC 0,06 %\n1 GΩ do 10 GΩ CMC 0,12 %\n10 GΩ do 100 GΩ CMC 0,5 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedury wewnętrzne PP-LME-04 PP-LME-03","norm_bases":["PP-LME-04","PP-LME-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki rezystancji analogowe i cyfrowe\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n1 µΩ do 100 µΩ CMC 0,2 µΩ\n100 µΩ do 1 mΩ CMC 0,2 %\n1 mΩ do 10 mΩ CMC 0,037 %\n10 mΩ do 100 mΩ CMC 0,028 %\n100 mΩ do 1 Ω CMC 0,065 %\n1 Ω do 10 Ω CMC 0,0035 % + 0,06 mΩ\n10 Ω do 100 Ω CMC 0,0031 % + 0,46 mΩ\n100 Ω do 1 kΩ CMC 0,0024 % + 3,8 mΩ\n1 kΩ do 10 kΩ CMC 0,0031 % + 0,038 Ω\n10 kΩ do 100 kΩ CMC 0,0031 % + 0,39 Ω\n100 kΩ do 1 MΩ CMC 0,003 % + 5,1 Ω\n1 MΩ do 10 MΩ CMC 0,022 % + 0,13 kΩ\n10 MΩ do 100 MΩ CMC 0,024 %\n100 MΩ do 1 GΩ CMC 0,06 %\n1 GΩ do 10 GΩ CMC 0,12 %\n10 GΩ do 100 GΩ CMC 0,5 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedury wewnętrzne PP-LME-04 PP-LME-03 Mierniki rezystancji analogowe i cyfrowe\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n1 µΩ do 100 µΩ CMC 0,2 µΩ\n100 µΩ do 1 mΩ CMC 0,2 %\n1 mΩ do 10 mΩ CMC 0,037 %\n10 mΩ do 100 mΩ CMC 0,028 %\n100 mΩ do 1 Ω CMC 0,065 %\n1 Ω do 10 Ω CMC 0,0035 % + 0,06 mΩ\n10 Ω do 100 Ω CMC 0,0031 % + 0,46 mΩ\n100 Ω do 1 kΩ CMC 0,0024 % + 3,8 mΩ\n1 kΩ do 10 kΩ CMC 0,0031 % + 0,038 Ω\n10 kΩ do 100 kΩ CMC 0,0031 % + 0,39 Ω\n100 kΩ do 1 MΩ CMC 0,003 % + 5,1 Ω\n1 MΩ do 10 MΩ CMC 0,022 % + 0,13 kΩ\n10 MΩ do 100 MΩ CMC 0,024 %\n100 MΩ do 1 GΩ CMC 0,06 %\n1 GΩ do 10 GΩ CMC 0,12 %\n10 GΩ do 100 GΩ CMC 0,5 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedury wewnetrzne PP-LME-04 PP-LME-03","search_en":"Analogue and digital ohmmeters Multimeters Calibration — DC resistance Internal procedure; At permanent location (S) DC resistance Internal procedure At permanent location (S) Internal procedures PP-LME-04 PP-LME-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":35,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedures PP-LME-04 PP-LME-03","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"1 µΩ to 100 µΩ","cmc":"0,2 µΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"0,2 %"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"0,037 %"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"0,028 %"},{"name":"","range":"100 mΩ to 1 Ω","cmc":"0,065 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,024 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,06 %"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,12 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,5 %"}],"reference_de":"Interne Verfahren PP-LME-04 PP-LME-03","regulatory_area_de":"DC-Widerstand","search_de":"Analoge und digitale Widerstandsmessgeräte Multimeter Kalibrierung — DC-Widerstand Internes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Am festen Standort (S) Interne Verfahren PP-LME-04 PP-LME-03","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge und digitale Widerstandsmessgeräte\nMultimeter","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"1 µΩ to 100 µΩ","cmc":"0,2 µΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"0,2 %"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"0,037 %"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"0,028 %"},{"name":"","range":"100 mΩ to 1 Ω","cmc":"0,065 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,024 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,06 %"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,12 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,5 %"}],"reference_zh":"内部程序 PP-LME-04 PP-LME-03","regulatory_area_zh":"直流电阻","search_zh":"模拟和数字电阻测量仪 万用表 校准 — 直流电阻 内部程序；在固定地点 (S) 直流电阻 内部程序 在固定地点 (S) 内部程序 PP-LME-04 PP-LME-03","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"模拟和数字电阻测量仪\n万用表","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"1 µΩ to 100 µΩ","cmc":"0,2 µΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"0,2 %"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"0,037 %"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"0,028 %"},{"name":"","range":"100 mΩ to 1 Ω","cmc":"0,065 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,0035 % + 0,06 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,0031 % + 0,46 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0024 % + 3,8 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0031 % + 0,038 Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0031 % + 0,39 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,003 % + 5,1 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,022 % + 0,13 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,024 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,06 %"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,12 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,5 %"}],"reference_cs":"Interní postupy PP-LME-04 PP-LME-03","regulatory_area_cs":"Odpor DC","search_cs":"Analogové a digitální měřiče odporu Multimetry Kalibrace — Odpor DC Vnitřní postup; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Ve stálé lokalitě (S) Interní postupy PP-LME-04 PP-LME-03","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové a digitální měřiče odporu\nMultimetry"},{"_id":"4b45e25d9a35e69cd1ab4038","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Boczniki\nMierniki rezystancji cyfrowe\nMostki\nRezystory stałe i regulowane","test_object_en":"Shunts\nDigital ohmmeters\nBridges\nFixed and variable resistors","methodology":"Wzorcowanie — Rezystancja AC","methodology_en":"Calibration — AC resistance","parameters":[{"name":"40 Hz do 1 kHz","range":"1 mΩ do 1 Ω","cmc":"0,21 %"},{"name":"40 Hz do 1 kHz","range":"1 Ω do 1 MΩ","cmc":"0,02 %"},{"name":"1 kHz","range":"1 mΩ do 1 Ω","cmc":"0,19 %"},{"name":"1 kHz","range":"1 Ω do 10 Ω","cmc":"0,06 %"},{"name":"1 kHz","range":"10 Ω do 100 kΩ","cmc":"0,03 %"},{"name":"1 kHz","range":"100 kΩ do 1 MΩ","cmc":"0,04 %"},{"name":"1 kHz","range":"1 MΩ do 10 MΩ","cmc":"0,13 %"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"1 mΩ to 1 Ω","cmc":"0,21 %"},{"name":"40 Hz to 1 kHz","range":"1 Ω to 1 MΩ","cmc":"0,02 %"},{"name":"1 kHz","range":"1 mΩ to 1 Ω","cmc":"0,19 %"},{"name":"1 kHz","range":"1 Ω to 10 Ω","cmc":"0,06 %"},{"name":"1 kHz","range":"10 Ω to 100 kΩ","cmc":"0,03 %"},{"name":"1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,04 %"},{"name":"1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,13 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja AC\nZakres:\n40 Hz do 1 kHz 1 mΩ do 1 Ω CMC 0,21 %\n40 Hz do 1 kHz 1 Ω do 1 MΩ CMC 0,02 %\n1 kHz 1 mΩ do 1 Ω CMC 0,19 %\n1 kHz 1 Ω do 10 Ω CMC 0,06 %\n1 kHz 10 Ω do 100 kΩ CMC 0,03 %\n1 kHz 100 kΩ do 1 MΩ CMC 0,04 %\n1 kHz 1 MΩ do 10 MΩ CMC 0,13 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedury wewnętrzne PP-LME-04 PP-LME-01","norm_bases":["PP-LME-04","PP-LME-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja AC","regulatory_area_en":"AC resistance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Boczniki\nMierniki rezystancji cyfrowe\nMostki\nRezystory stałe i regulowane Wzorcowanie — Rezystancja AC\nZakres:\n40 Hz do 1 kHz 1 mΩ do 1 Ω CMC 0,21 %\n40 Hz do 1 kHz 1 Ω do 1 MΩ CMC 0,02 %\n1 kHz 1 mΩ do 1 Ω CMC 0,19 %\n1 kHz 1 Ω do 10 Ω CMC 0,06 %\n1 kHz 10 Ω do 100 kΩ CMC 0,03 %\n1 kHz 100 kΩ do 1 MΩ CMC 0,04 %\n1 kHz 1 MΩ do 10 MΩ CMC 0,13 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedury wewnętrzne PP-LME-04 PP-LME-01 Boczniki\nMierniki rezystancji cyfrowe\nMostki\nRezystory stale i regulowane Wzorcowanie — Rezystancja AC\nZakres:\n40 Hz do 1 kHz 1 mΩ do 1 Ω CMC 0,21 %\n40 Hz do 1 kHz 1 Ω do 1 MΩ CMC 0,02 %\n1 kHz 1 mΩ do 1 Ω CMC 0,19 %\n1 kHz 1 Ω do 10 Ω CMC 0,06 %\n1 kHz 10 Ω do 100 kΩ CMC 0,03 %\n1 kHz 100 kΩ do 1 MΩ CMC 0,04 %\n1 kHz 1 MΩ do 10 MΩ CMC 0,13 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedury wewnetrzne PP-LME-04 PP-LME-01","search_en":"Shunts Digital ohmmeters Bridges Fixed and variable resistors Calibration — AC resistance Internal procedure; At permanent location (S) AC resistance Internal procedure At permanent location (S) 40 Hz to 1 kHz 40 Hz to 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz Internal procedures PP-LME-04 PP-LME-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":36,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedures PP-LME-04 PP-LME-01","methodology_de":"Kalibrierung — Wechselstromwiderstand","parameters_de":[{"name":"40 Hz bis 1 kHz","range":"1 mΩ to 1 Ω","cmc":"0,21 %"},{"name":"40 Hz bis 1 kHz","range":"1 Ω to 1 MΩ","cmc":"0,02 %"},{"name":"1 kHz","range":"1 mΩ to 1 Ω","cmc":"0,19 %"},{"name":"1 kHz","range":"1 Ω to 10 Ω","cmc":"0,06 %"},{"name":"1 kHz","range":"10 Ω to 100 kΩ","cmc":"0,03 %"},{"name":"1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,04 %"},{"name":"1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,13 %"}],"reference_de":"Interne Verfahren PP-LME-04 PP-LME-01","regulatory_area_de":"AC-Widerstand","search_de":"Shunts Digitale Widerstandsmessgeräte Messbrücken Fest- und einstellbare Widerstände Kalibrierung — Wechselstromwiderstand Internes Verfahren; Am festen Standort (S) AC-Widerstand Internes Verfahren Am festen Standort (S) 40 Hz bis 1 kHz 40 Hz bis 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz Interne Verfahren PP-LME-04 PP-LME-01","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Shunts\nDigitale Widerstandsmessgeräte\nMessbrücken\nFest- und einstellbare Widerstände","methodology_zh":"校准 — 交流电阻","parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"1 mΩ to 1 Ω","cmc":"0,21 %"},{"name":"40 Hz 至 1 kHz","range":"1 Ω to 1 MΩ","cmc":"0,02 %"},{"name":"1 kHz","range":"1 mΩ to 1 Ω","cmc":"0,19 %"},{"name":"1 kHz","range":"1 Ω to 10 Ω","cmc":"0,06 %"},{"name":"1 kHz","range":"10 Ω to 100 kΩ","cmc":"0,03 %"},{"name":"1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,04 %"},{"name":"1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,13 %"}],"reference_zh":"内部程序 PP-LME-04 PP-LME-01","regulatory_area_zh":"交流电阻","search_zh":"分流器 数字电阻测量仪 电桥 固定和可调电阻器 校准 — 交流电阻 内部程序；在固定地点 (S) 交流电阻 内部程序 在固定地点 (S) 40 Hz 至 1 kHz 40 Hz 至 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 内部程序 PP-LME-04 PP-LME-01","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"分流器\n数字电阻测量仪\n电桥\n固定和可调电阻器","methodology_cs":"Kalibrace — Odpor AC","parameters_cs":[{"name":"40 Hz až 1 kHz","range":"1 mΩ to 1 Ω","cmc":"0,21 %"},{"name":"40 Hz až 1 kHz","range":"1 Ω to 1 MΩ","cmc":"0,02 %"},{"name":"1 kHz","range":"1 mΩ to 1 Ω","cmc":"0,19 %"},{"name":"1 kHz","range":"1 Ω to 10 Ω","cmc":"0,06 %"},{"name":"1 kHz","range":"10 Ω to 100 kΩ","cmc":"0,03 %"},{"name":"1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,04 %"},{"name":"1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,13 %"}],"reference_cs":"Interní postupy PP-LME-04 PP-LME-01","regulatory_area_cs":"Odpor AC","search_cs":"Bočníky Digitální měřiče odporu Můstky Pevné a nastavitelné rezistory Kalibrace — Odpor AC Vnitřní postup; Ve stálé lokalitě (S) Odpor AC Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 1 kHz 40 Hz až 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz Interní postupy PP-LME-04 PP-LME-01","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Bočníky\nDigitální měřiče odporu\nMůstky\nPevné a nastavitelné rezistory"},{"_id":"435a274f7c4103e072e78585","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Kondensatory wzorcowe stałe i regulowane","test_object_en":"Fixed and variable standard capacitors","methodology":"Wzorcowanie — Pojemność","methodology_en":"Calibration — Capacitance","parameters":[{"name":"1 kHz","range":"10 pF","cmc":"0,2 %"},{"name":"1 kHz","range":"20 pF do 50 pF","cmc":"0,1 %"},{"name":"1 kHz","range":"50 pF do 100 pF","cmc":"0,06 %"},{"name":"1 kHz","range":"100 pF do 10 µF","cmc":"0,02 %"},{"name":"1 kHz","range":"10 µF do 100 µF","cmc":"0,04 %"},{"name":"1 kHz","range":"100 µF do 1200 µF","cmc":"0,3 %"},{"name":"400 Hz","range":"10 pF do 50 pF","cmc":"0,9 %"},{"name":"400 Hz","range":"50 pF do 1 nF","cmc":"0,2 %"},{"name":"40 Hz do 1 kHz","range":"1 nF","cmc":"0,21 %"},{"name":"40 Hz do 1 kHz","range":"10 nF do 100 µF","cmc":"0,06 %"},{"name":"40 Hz do 1 kHz","range":"100 µF do 1200 µF","cmc":"0,3 %"}],"parameters_en":[{"name":"1 kHz","range":"10 pF","cmc":"0,2 %"},{"name":"1 kHz","range":"20 pF to 50 pF","cmc":"0,1 %"},{"name":"1 kHz","range":"50 pF to 100 pF","cmc":"0,06 %"},{"name":"1 kHz","range":"100 pF to 10 µF","cmc":"0,02 %"},{"name":"1 kHz","range":"10 µF to 100 µF","cmc":"0,04 %"},{"name":"1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"},{"name":"400 Hz","range":"10 pF to 50 pF","cmc":"0,9 %"},{"name":"400 Hz","range":"50 pF to 1 nF","cmc":"0,2 %"},{"name":"40 Hz to 1 kHz","range":"1 nF","cmc":"0,21 %"},{"name":"40 Hz to 1 kHz","range":"10 nF to 100 µF","cmc":"0,06 %"},{"name":"40 Hz to 1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Pojemność\nZakres:\n1 kHz 10 pF CMC 0,2 %\n1 kHz 20 pF do 50 pF CMC 0,1 %\n1 kHz 50 pF do 100 pF CMC 0,06 %\n1 kHz 100 pF do 10 µF CMC 0,02 %\n1 kHz 10 µF do 100 µF CMC 0,04 %\n1 kHz 100 µF do 1200 µF CMC 0,3 %\n400 Hz 10 pF do 50 pF CMC 0,9 %\n400 Hz 50 pF do 1 nF CMC 0,2 %\n40 Hz do 1 kHz 1 nF CMC 0,21 %\n40 Hz do 1 kHz 10 nF do 100 µF CMC 0,06 %\n40 Hz do 1 kHz 100 µF do 1200 µF CMC 0,3 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LME-02","norm_bases":["PP-LME-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Pojemność","regulatory_area_en":"Capacitance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kondensatory wzorcowe stałe i regulowane Wzorcowanie — Pojemność\nZakres:\n1 kHz 10 pF CMC 0,2 %\n1 kHz 20 pF do 50 pF CMC 0,1 %\n1 kHz 50 pF do 100 pF CMC 0,06 %\n1 kHz 100 pF do 10 µF CMC 0,02 %\n1 kHz 10 µF do 100 µF CMC 0,04 %\n1 kHz 100 µF do 1200 µF CMC 0,3 %\n400 Hz 10 pF do 50 pF CMC 0,9 %\n400 Hz 50 pF do 1 nF CMC 0,2 %\n40 Hz do 1 kHz 1 nF CMC 0,21 %\n40 Hz do 1 kHz 10 nF do 100 µF CMC 0,06 %\n40 Hz do 1 kHz 100 µF do 1200 µF CMC 0,3 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP-LME-02 Kondensatory wzorcowe stale i regulowane Wzorcowanie — Pojemnosc\nZakres:\n1 kHz 10 pF CMC 0,2 %\n1 kHz 20 pF do 50 pF CMC 0,1 %\n1 kHz 50 pF do 100 pF CMC 0,06 %\n1 kHz 100 pF do 10 µF CMC 0,02 %\n1 kHz 10 µF do 100 µF CMC 0,04 %\n1 kHz 100 µF do 1200 µF CMC 0,3 %\n400 Hz 10 pF do 50 pF CMC 0,9 %\n400 Hz 50 pF do 1 nF CMC 0,2 %\n40 Hz do 1 kHz 1 nF CMC 0,21 %\n40 Hz do 1 kHz 10 nF do 100 µF CMC 0,06 %\n40 Hz do 1 kHz 100 µF do 1200 µF CMC 0,3 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP-LME-02","search_en":"Fixed and variable standard capacitors Calibration — Capacitance Internal procedure; At permanent location (S) Capacitance Internal procedure At permanent location (S) 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 400 Hz 400 Hz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz Internal procedure PP-LME-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":37,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LME-02","methodology_de":"Kalibrierung — Kapazität","parameters_de":[{"name":"1 kHz","range":"10 pF","cmc":"0,2 %"},{"name":"1 kHz","range":"20 pF to 50 pF","cmc":"0,1 %"},{"name":"1 kHz","range":"50 pF to 100 pF","cmc":"0,06 %"},{"name":"1 kHz","range":"100 pF to 10 µF","cmc":"0,02 %"},{"name":"1 kHz","range":"10 µF to 100 µF","cmc":"0,04 %"},{"name":"1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"},{"name":"400 Hz","range":"10 pF to 50 pF","cmc":"0,9 %"},{"name":"400 Hz","range":"50 pF to 1 nF","cmc":"0,2 %"},{"name":"40 Hz bis 1 kHz","range":"1 nF","cmc":"0,21 %"},{"name":"40 Hz bis 1 kHz","range":"10 nF to 100 µF","cmc":"0,06 %"},{"name":"40 Hz bis 1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"}],"reference_de":"Internes Verfahren PP-LME-02","regulatory_area_de":"Kapazität","search_de":"Feste und einstellbare Normalkondensatoren Kalibrierung — Kapazität Internes Verfahren; Am festen Standort (S) Kapazität Internes Verfahren Am festen Standort (S) 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 400 Hz 400 Hz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz Internes Verfahren PP-LME-02","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Feste und einstellbare Normalkondensatoren","methodology_zh":"校准 — 电容","parameters_zh":[{"name":"1 kHz","range":"10 pF","cmc":"0,2 %"},{"name":"1 kHz","range":"20 pF to 50 pF","cmc":"0,1 %"},{"name":"1 kHz","range":"50 pF to 100 pF","cmc":"0,06 %"},{"name":"1 kHz","range":"100 pF to 10 µF","cmc":"0,02 %"},{"name":"1 kHz","range":"10 µF to 100 µF","cmc":"0,04 %"},{"name":"1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"},{"name":"400 Hz","range":"10 pF to 50 pF","cmc":"0,9 %"},{"name":"400 Hz","range":"50 pF to 1 nF","cmc":"0,2 %"},{"name":"40 Hz 至 1 kHz","range":"1 nF","cmc":"0,21 %"},{"name":"40 Hz 至 1 kHz","range":"10 nF to 100 µF","cmc":"0,06 %"},{"name":"40 Hz 至 1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"}],"reference_zh":"内部程序 PP-LME-02","regulatory_area_zh":"容量","search_zh":"固定和可调标准电容器 校准 — 电容 内部程序；在固定地点 (S) 容量 内部程序 在固定地点 (S) 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 400 Hz 400 Hz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 内部程序 PP-LME-02","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"固定和可调标准电容器","methodology_cs":"Kalibrace — Kapacita","parameters_cs":[{"name":"1 kHz","range":"10 pF","cmc":"0,2 %"},{"name":"1 kHz","range":"20 pF to 50 pF","cmc":"0,1 %"},{"name":"1 kHz","range":"50 pF to 100 pF","cmc":"0,06 %"},{"name":"1 kHz","range":"100 pF to 10 µF","cmc":"0,02 %"},{"name":"1 kHz","range":"10 µF to 100 µF","cmc":"0,04 %"},{"name":"1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"},{"name":"400 Hz","range":"10 pF to 50 pF","cmc":"0,9 %"},{"name":"400 Hz","range":"50 pF to 1 nF","cmc":"0,2 %"},{"name":"40 Hz až 1 kHz","range":"1 nF","cmc":"0,21 %"},{"name":"40 Hz až 1 kHz","range":"10 nF to 100 µF","cmc":"0,06 %"},{"name":"40 Hz až 1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"}],"reference_cs":"Vnitřní postup PP-LME-02","regulatory_area_cs":"Objem","search_cs":"Pevné a nastavitelné etalony kapacity Kalibrace — Kapacita Vnitřní postup; Ve stálé lokalitě (S) Objem Vnitřní postup Ve stálé lokalitě (S) 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 400 Hz 400 Hz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz Vnitřní postup PP-LME-02","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Pevné a nastavitelné etalony kapacity"},{"_id":"349e1e2b15ddc4181c405231","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Mostki,\nMierniki pojemności\nMultimetry","test_object_en":"Bridges,\nCapacitance meters\nMultimeters","methodology":"Wzorcowanie — Pojemność","methodology_en":"Calibration — Capacitance","parameters":[{"name":"1 kHz","range":"50 pF do 100 pF","cmc":"0,06 %"},{"name":"1 kHz","range":"100 pF do 10 µF","cmc":"0,02 %"},{"name":"1 kHz","range":"10 µF do 100 µF","cmc":"0,04 %"},{"name":"1 kHz","range":"100 µF do 1200 µF","cmc":"0,3 %"},{"name":"400 Hz","range":"50 pF do 1 nF","cmc":"0,2 %"},{"name":"40 Hz do 1 kHz","range":"1 nF","cmc":"0,21 %"},{"name":"40 Hz do 1 kHz","range":"10 nF do 100 µF","cmc":"0,06 %"},{"name":"40 Hz do 1 kHz","range":"100 µF do 1200 µF","cmc":"0,3 %"}],"parameters_en":[{"name":"1 kHz","range":"50 pF to 100 pF","cmc":"0,06 %"},{"name":"1 kHz","range":"100 pF to 10 µF","cmc":"0,02 %"},{"name":"1 kHz","range":"10 µF to 100 µF","cmc":"0,04 %"},{"name":"1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"},{"name":"400 Hz","range":"50 pF to 1 nF","cmc":"0,2 %"},{"name":"40 Hz to 1 kHz","range":"1 nF","cmc":"0,21 %"},{"name":"40 Hz to 1 kHz","range":"10 nF to 100 µF","cmc":"0,06 %"},{"name":"40 Hz to 1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Pojemność\nZakres:\n1 kHz 50 pF do 100 pF CMC 0,06 %\n1 kHz 100 pF do 10 µF CMC 0,02 %\n1 kHz 10 µF do 100 µF CMC 0,04 %\n1 kHz 100 µF do 1200 µF CMC 0,3 %\n400 Hz 50 pF do 1 nF CMC 0,2 %\n40 Hz do 1 kHz 1 nF CMC 0,21 %\n40 Hz do 1 kHz 10 nF do 100 µF CMC 0,06 %\n40 Hz do 1 kHz 100 µF do 1200 µF CMC 0,3 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LME-04","norm_bases":["PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Pojemność","regulatory_area_en":"Capacitance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mostki,\nMierniki pojemności\nMultimetry Wzorcowanie — Pojemność\nZakres:\n1 kHz 50 pF do 100 pF CMC 0,06 %\n1 kHz 100 pF do 10 µF CMC 0,02 %\n1 kHz 10 µF do 100 µF CMC 0,04 %\n1 kHz 100 µF do 1200 µF CMC 0,3 %\n400 Hz 50 pF do 1 nF CMC 0,2 %\n40 Hz do 1 kHz 1 nF CMC 0,21 %\n40 Hz do 1 kHz 10 nF do 100 µF CMC 0,06 %\n40 Hz do 1 kHz 100 µF do 1200 µF CMC 0,3 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP-LME-04 Mostki,\nMierniki pojemnosci\nMultimetry Wzorcowanie — Pojemnosc\nZakres:\n1 kHz 50 pF do 100 pF CMC 0,06 %\n1 kHz 100 pF do 10 µF CMC 0,02 %\n1 kHz 10 µF do 100 µF CMC 0,04 %\n1 kHz 100 µF do 1200 µF CMC 0,3 %\n400 Hz 50 pF do 1 nF CMC 0,2 %\n40 Hz do 1 kHz 1 nF CMC 0,21 %\n40 Hz do 1 kHz 10 nF do 100 µF CMC 0,06 %\n40 Hz do 1 kHz 100 µF do 1200 µF CMC 0,3 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP-LME-04","search_en":"Bridges, Capacitance meters Multimeters Calibration — Capacitance Internal procedure; At permanent location (S) Capacitance Internal procedure At permanent location (S) 1 kHz 1 kHz 1 kHz 1 kHz 400 Hz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz Internal procedure PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":38,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LME-04","methodology_de":"Kalibrierung — Kapazität","parameters_de":[{"name":"1 kHz","range":"50 pF to 100 pF","cmc":"0,06 %"},{"name":"1 kHz","range":"100 pF to 10 µF","cmc":"0,02 %"},{"name":"1 kHz","range":"10 µF to 100 µF","cmc":"0,04 %"},{"name":"1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"},{"name":"400 Hz","range":"50 pF to 1 nF","cmc":"0,2 %"},{"name":"40 Hz bis 1 kHz","range":"1 nF","cmc":"0,21 %"},{"name":"40 Hz bis 1 kHz","range":"10 nF to 100 µF","cmc":"0,06 %"},{"name":"40 Hz bis 1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"}],"reference_de":"Internes Verfahren PP-LME-04","regulatory_area_de":"Kapazität","search_de":"Messbrücken, Kapazitätsmessgeräte Multimeter Kalibrierung — Kapazität Internes Verfahren; Am festen Standort (S) Kapazität Internes Verfahren Am festen Standort (S) 1 kHz 1 kHz 1 kHz 1 kHz 400 Hz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz Internes Verfahren PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Messbrücken,\nKapazitätsmessgeräte\nMultimeter","methodology_zh":"校准 — 电容","parameters_zh":[{"name":"1 kHz","range":"50 pF to 100 pF","cmc":"0,06 %"},{"name":"1 kHz","range":"100 pF to 10 µF","cmc":"0,02 %"},{"name":"1 kHz","range":"10 µF to 100 µF","cmc":"0,04 %"},{"name":"1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"},{"name":"400 Hz","range":"50 pF to 1 nF","cmc":"0,2 %"},{"name":"40 Hz 至 1 kHz","range":"1 nF","cmc":"0,21 %"},{"name":"40 Hz 至 1 kHz","range":"10 nF to 100 µF","cmc":"0,06 %"},{"name":"40 Hz 至 1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"}],"reference_zh":"内部程序 PP-LME-04","regulatory_area_zh":"容量","search_zh":"电桥， 电容表 万用表 校准 — 电容 内部程序；在固定地点 (S) 容量 内部程序 在固定地点 (S) 1 kHz 1 kHz 1 kHz 1 kHz 400 Hz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 内部程序 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电桥，\n电容表\n万用表","methodology_cs":"Kalibrace — Kapacita","parameters_cs":[{"name":"1 kHz","range":"50 pF to 100 pF","cmc":"0,06 %"},{"name":"1 kHz","range":"100 pF to 10 µF","cmc":"0,02 %"},{"name":"1 kHz","range":"10 µF to 100 µF","cmc":"0,04 %"},{"name":"1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"},{"name":"400 Hz","range":"50 pF to 1 nF","cmc":"0,2 %"},{"name":"40 Hz až 1 kHz","range":"1 nF","cmc":"0,21 %"},{"name":"40 Hz až 1 kHz","range":"10 nF to 100 µF","cmc":"0,06 %"},{"name":"40 Hz až 1 kHz","range":"100 µF to 1200 µF","cmc":"0,3 %"}],"reference_cs":"Vnitřní postup PP-LME-04","regulatory_area_cs":"Objem","search_cs":"Můstky, Měřiče kapacity Multimetry Kalibrace — Kapacita Vnitřní postup; Ve stálé lokalitě (S) Objem Vnitřní postup Ve stálé lokalitě (S) 1 kHz 1 kHz 1 kHz 1 kHz 400 Hz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz Vnitřní postup PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Můstky,\nMěřiče kapacity\nMultimetry"},{"_id":"60f864f3e1d15e992701b4af","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Cewki wzorcowe stałe i regulowane","test_object_en":"Fixed and variable standard inductors","methodology":"Wzorcowanie — Indukcyjność","methodology_en":"Calibration — Inductance","parameters":[{"name":"1 kHz","range":"10 µH do 100 µH","cmc":"0,6%"},{"name":"1 kHz","range":"100 µH do 1 mH","cmc":"0,07 %"},{"name":"1 kHz","range":"1 mH do 65 H","cmc":"0,03 %"},{"name":"40 Hz do 1 kHz","range":"1 mH do 10 mH","cmc":"0,6 %"},{"name":"40 Hz do 1 kHz","range":"10 mH do 100 mH","cmc":"0,1 %"},{"name":"40 Hz do 1 kHz","range":"100 mH do 65 H","cmc":"0,07 %"}],"parameters_en":[{"name":"1 kHz","range":"10 µH to 100 µH","cmc":"0,6%"},{"name":"1 kHz","range":"100 µH to 1 mH","cmc":"0,07 %"},{"name":"1 kHz","range":"1 mH to 65 H","cmc":"0,03 %"},{"name":"40 Hz to 1 kHz","range":"1 mH to 10 mH","cmc":"0,6 %"},{"name":"40 Hz to 1 kHz","range":"10 mH to 100 mH","cmc":"0,1 %"},{"name":"40 Hz to 1 kHz","range":"100 mH to 65 H","cmc":"0,07 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Indukcyjność\nZakres:\n1 kHz 10 µH do 100 µH CMC 0,6%\n1 kHz 100 µH do 1 mH CMC 0,07 %\n1 kHz 1 mH do 65 H CMC 0,03 %\n40 Hz do 1 kHz 1 mH do 10 mH CMC 0,6 %\n40 Hz do 1 kHz 10 mH do 100 mH CMC 0,1 %\n40 Hz do 1 kHz 100 mH do 65 H CMC 0,07 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LME-02","norm_bases":["PP-LME-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Indukcyjność","regulatory_area_en":"Inductance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Cewki wzorcowe stałe i regulowane Wzorcowanie — Indukcyjność\nZakres:\n1 kHz 10 µH do 100 µH CMC 0,6%\n1 kHz 100 µH do 1 mH CMC 0,07 %\n1 kHz 1 mH do 65 H CMC 0,03 %\n40 Hz do 1 kHz 1 mH do 10 mH CMC 0,6 %\n40 Hz do 1 kHz 10 mH do 100 mH CMC 0,1 %\n40 Hz do 1 kHz 100 mH do 65 H CMC 0,07 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP-LME-02 Cewki wzorcowe stale i regulowane Wzorcowanie — Indukcyjnosc\nZakres:\n1 kHz 10 µH do 100 µH CMC 0,6%\n1 kHz 100 µH do 1 mH CMC 0,07 %\n1 kHz 1 mH do 65 H CMC 0,03 %\n40 Hz do 1 kHz 1 mH do 10 mH CMC 0,6 %\n40 Hz do 1 kHz 10 mH do 100 mH CMC 0,1 %\n40 Hz do 1 kHz 100 mH do 65 H CMC 0,07 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP-LME-02","search_en":"Fixed and variable standard inductors Calibration — Inductance Internal procedure; At permanent location (S) Inductance Internal procedure At permanent location (S) 1 kHz 1 kHz 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz Internal procedure PP-LME-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":39,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LME-02","methodology_de":"Kalibrierung — Induktivität","parameters_de":[{"name":"1 kHz","range":"10 µH to 100 µH","cmc":"0,6%"},{"name":"1 kHz","range":"100 µH to 1 mH","cmc":"0,07 %"},{"name":"1 kHz","range":"1 mH to 65 H","cmc":"0,03 %"},{"name":"40 Hz bis 1 kHz","range":"1 mH to 10 mH","cmc":"0,6 %"},{"name":"40 Hz bis 1 kHz","range":"10 mH to 100 mH","cmc":"0,1 %"},{"name":"40 Hz bis 1 kHz","range":"100 mH to 65 H","cmc":"0,07 %"}],"reference_de":"Internes Verfahren PP-LME-02","regulatory_area_de":"Induktivität","search_de":"Feste und einstellbare Normalinduktivitäten Kalibrierung — Induktivität Internes Verfahren; Am festen Standort (S) Induktivität Internes Verfahren Am festen Standort (S) 1 kHz 1 kHz 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz Internes Verfahren PP-LME-02","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Feste und einstellbare Normalinduktivitäten","methodology_zh":"校准 — 电感","parameters_zh":[{"name":"1 kHz","range":"10 µH to 100 µH","cmc":"0,6%"},{"name":"1 kHz","range":"100 µH to 1 mH","cmc":"0,07 %"},{"name":"1 kHz","range":"1 mH to 65 H","cmc":"0,03 %"},{"name":"40 Hz 至 1 kHz","range":"1 mH to 10 mH","cmc":"0,6 %"},{"name":"40 Hz 至 1 kHz","range":"10 mH to 100 mH","cmc":"0,1 %"},{"name":"40 Hz 至 1 kHz","range":"100 mH to 65 H","cmc":"0,07 %"}],"reference_zh":"内部程序 PP-LME-02","regulatory_area_zh":"电感","search_zh":"固定和可调标准电感器 校准 — 电感 内部程序；在固定地点 (S) 电感 内部程序 在固定地点 (S) 1 kHz 1 kHz 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 内部程序 PP-LME-02","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"固定和可调标准电感器","methodology_cs":"Kalibrace — Indukčnost","parameters_cs":[{"name":"1 kHz","range":"10 µH to 100 µH","cmc":"0,6%"},{"name":"1 kHz","range":"100 µH to 1 mH","cmc":"0,07 %"},{"name":"1 kHz","range":"1 mH to 65 H","cmc":"0,03 %"},{"name":"40 Hz až 1 kHz","range":"1 mH to 10 mH","cmc":"0,6 %"},{"name":"40 Hz až 1 kHz","range":"10 mH to 100 mH","cmc":"0,1 %"},{"name":"40 Hz až 1 kHz","range":"100 mH to 65 H","cmc":"0,07 %"}],"reference_cs":"Vnitřní postup PP-LME-02","regulatory_area_cs":"Indukčnost","search_cs":"Pevné a nastavitelné etalony indukčnosti Kalibrace — Indukčnost Vnitřní postup; Ve stálé lokalitě (S) Indukčnost Vnitřní postup Ve stálé lokalitě (S) 1 kHz 1 kHz 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz Vnitřní postup PP-LME-02","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Pevné a nastavitelné etalony indukčnosti"},{"_id":"2c89dacf109c29a9d7063405","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Mostki\nMierniki indukcyjności","test_object_en":"Bridges\nInductance meters","methodology":"Wzorcowanie — Indukcyjność","methodology_en":"Calibration — Inductance","parameters":[{"name":"1 kHz","range":"10 µH do 100 µH","cmc":"0,6 %"},{"name":"1 kHz","range":"100 µH do 1 mH","cmc":"0,13 %"},{"name":"1 kHz","range":"1 mH do 15 H","cmc":"0,07 %"},{"name":"40 Hz do 1 kHz","range":"1 mH do 10 mH","cmc":"0,6 %"},{"name":"40 Hz do 1 kHz","range":"10 mH do 100 mH","cmc":"0,1 %"},{"name":"40 Hz do 1 kHz","range":"100 mH do 15 H","cmc":"0,07 %"}],"parameters_en":[{"name":"1 kHz","range":"10 µH to 100 µH","cmc":"0,6 %"},{"name":"1 kHz","range":"100 µH to 1 mH","cmc":"0,13 %"},{"name":"1 kHz","range":"1 mH to 15 H","cmc":"0,07 %"},{"name":"40 Hz to 1 kHz","range":"1 mH to 10 mH","cmc":"0,6 %"},{"name":"40 Hz to 1 kHz","range":"10 mH to 100 mH","cmc":"0,1 %"},{"name":"40 Hz to 1 kHz","range":"100 mH to 15 H","cmc":"0,07 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Indukcyjność\nZakres:\n1 kHz 10 µH do 100 µH CMC 0,6 %\n1 kHz 100 µH do 1 mH CMC 0,13 %\n1 kHz 1 mH do 15 H CMC 0,07 %\n40 Hz do 1 kHz 1 mH do 10 mH CMC 0,6 %\n40 Hz do 1 kHz 10 mH do 100 mH CMC 0,1 %\n40 Hz do 1 kHz 100 mH do 15 H CMC 0,07 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP-LME-04","norm_bases":["PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Indukcyjność","regulatory_area_en":"Inductance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mostki\nMierniki indukcyjności Wzorcowanie — Indukcyjność\nZakres:\n1 kHz 10 µH do 100 µH CMC 0,6 %\n1 kHz 100 µH do 1 mH CMC 0,13 %\n1 kHz 1 mH do 15 H CMC 0,07 %\n40 Hz do 1 kHz 1 mH do 10 mH CMC 0,6 %\n40 Hz do 1 kHz 10 mH do 100 mH CMC 0,1 %\n40 Hz do 1 kHz 100 mH do 15 H CMC 0,07 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP-LME-04 Mostki\nMierniki indukcyjnosci Wzorcowanie — Indukcyjnosc\nZakres:\n1 kHz 10 µH do 100 µH CMC 0,6 %\n1 kHz 100 µH do 1 mH CMC 0,13 %\n1 kHz 1 mH do 15 H CMC 0,07 %\n40 Hz do 1 kHz 1 mH do 10 mH CMC 0,6 %\n40 Hz do 1 kHz 10 mH do 100 mH CMC 0,1 %\n40 Hz do 1 kHz 100 mH do 15 H CMC 0,07 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP-LME-04","search_en":"Bridges Inductance meters Calibration — Inductance Internal procedure; At permanent location (S) Inductance Internal procedure At permanent location (S) 1 kHz 1 kHz 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz Internal procedure PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":40,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP-LME-04","methodology_de":"Kalibrierung — Induktivität","parameters_de":[{"name":"1 kHz","range":"10 µH to 100 µH","cmc":"0,6 %"},{"name":"1 kHz","range":"100 µH to 1 mH","cmc":"0,13 %"},{"name":"1 kHz","range":"1 mH to 15 H","cmc":"0,07 %"},{"name":"40 Hz bis 1 kHz","range":"1 mH to 10 mH","cmc":"0,6 %"},{"name":"40 Hz bis 1 kHz","range":"10 mH to 100 mH","cmc":"0,1 %"},{"name":"40 Hz bis 1 kHz","range":"100 mH to 15 H","cmc":"0,07 %"}],"reference_de":"Internes Verfahren PP-LME-04","regulatory_area_de":"Induktivität","search_de":"Messbrücken Induktivitätsmessgeräte Kalibrierung — Induktivität Internes Verfahren; Am festen Standort (S) Induktivität Internes Verfahren Am festen Standort (S) 1 kHz 1 kHz 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz Internes Verfahren PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Messbrücken\nInduktivitätsmessgeräte","methodology_zh":"校准 — 电感","parameters_zh":[{"name":"1 kHz","range":"10 µH to 100 µH","cmc":"0,6 %"},{"name":"1 kHz","range":"100 µH to 1 mH","cmc":"0,13 %"},{"name":"1 kHz","range":"1 mH to 15 H","cmc":"0,07 %"},{"name":"40 Hz 至 1 kHz","range":"1 mH to 10 mH","cmc":"0,6 %"},{"name":"40 Hz 至 1 kHz","range":"10 mH to 100 mH","cmc":"0,1 %"},{"name":"40 Hz 至 1 kHz","range":"100 mH to 15 H","cmc":"0,07 %"}],"reference_zh":"内部程序 PP-LME-04","regulatory_area_zh":"电感","search_zh":"电桥 电感表 校准 — 电感 内部程序；在固定地点 (S) 电感 内部程序 在固定地点 (S) 1 kHz 1 kHz 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 内部程序 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电桥\n电感表","methodology_cs":"Kalibrace — Indukčnost","parameters_cs":[{"name":"1 kHz","range":"10 µH to 100 µH","cmc":"0,6 %"},{"name":"1 kHz","range":"100 µH to 1 mH","cmc":"0,13 %"},{"name":"1 kHz","range":"1 mH to 15 H","cmc":"0,07 %"},{"name":"40 Hz až 1 kHz","range":"1 mH to 10 mH","cmc":"0,6 %"},{"name":"40 Hz až 1 kHz","range":"10 mH to 100 mH","cmc":"0,1 %"},{"name":"40 Hz až 1 kHz","range":"100 mH to 15 H","cmc":"0,07 %"}],"reference_cs":"Vnitřní postup PP-LME-04","regulatory_area_cs":"Indukčnost","search_cs":"Můstky Měřiče indukčnosti Kalibrace — Indukčnost Vnitřní postup; Ve stálé lokalitě (S) Indukčnost Vnitřní postup Ve stálé lokalitě (S) 1 kHz 1 kHz 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz Vnitřní postup PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Můstky\nMěřiče indukčnosti"},{"_id":"0fb69d0dd6d0f3128435c044","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Mierniki mocy czynnej analogowe i cyfrowe jednofazowe","test_object_en":"Analogue and digital single-phase active power meters","methodology":"Wzorcowanie — Moc AC","methodology_en":"Calibration — AC power","parameters":[{"name":"40 Hz do 500 Hz; PF = 1; 1,3 V do 750 V; 0,005 A do 150 A","range":"6,5 mW do 112,5 kW","cmc":"0,15 %"}],"parameters_en":[{"name":"40 Hz to 500 Hz; PF = 1; 1,3 V to 750 V; 0,005 A to 150 A","range":"6,5 mW to 112,5 kW","cmc":"0,15 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moc AC\n40 Hz do 500 Hz; PF = 1; 1,3 V do 750 V; 0,005 A do 150 A 6,5 mW do 112,5 kW CMC 0,15 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedury wewnętrzne PP-LME-03 PP-LME-04","norm_bases":["PP-LME-03","PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moc AC","regulatory_area_en":"AC power","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki mocy czynnej analogowe i cyfrowe jednofazowe Wzorcowanie — Moc AC\n40 Hz do 500 Hz; PF = 1; 1,3 V do 750 V; 0,005 A do 150 A 6,5 mW do 112,5 kW CMC 0,15 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedury wewnętrzne PP-LME-03 PP-LME-04 Mierniki mocy czynnej analogowe i cyfrowe jednofazowe Wzorcowanie — Moc AC\n40 Hz do 500 Hz; PF = 1; 1,3 V do 750 V; 0,005 A do 150 A 6,5 mW do 112,5 kW CMC 0,15 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedury wewnetrzne PP-LME-03 PP-LME-04","search_en":"Analogue and digital single-phase active power meters Calibration — AC power Internal procedure; At permanent location (S) AC power Internal procedure At permanent location (S) 40 Hz to 500 Hz; PF = 1; 1,3 V to 750 V; 0,005 A to 150 A Internal procedures PP-LME-03 PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":41,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedures PP-LME-03 PP-LME-04","methodology_de":"Kalibrierung — AC-Leistung","parameters_de":[{"name":"40 Hz bis 500 Hz; PF = 1; 1,3 V bis 750 V; 0,005 A bis 150 A","range":"6,5 mW to 112,5 kW","cmc":"0,15 %"}],"reference_de":"Interne Verfahren PP-LME-03 PP-LME-04","regulatory_area_de":"AC-Leistung","search_de":"Analoge und digitale einphasige Wirkleistungsmessgeräte Kalibrierung — AC-Leistung Internes Verfahren; Am festen Standort (S) AC-Leistung Internes Verfahren Am festen Standort (S) 40 Hz bis 500 Hz; PF = 1; 1,3 V bis 750 V; 0,005 A bis 150 A Interne Verfahren PP-LME-03 PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge und digitale einphasige Wirkleistungsmessgeräte","methodology_zh":"校准 — 交流功率","parameters_zh":[{"name":"40 Hz 至 500 Hz；PF = 1；1,3 V 至 750 V；0,005 A 至 150 A","range":"6,5 mW to 112,5 kW","cmc":"0,15 %"}],"reference_zh":"内部程序 PP-LME-03 PP-LME-04","regulatory_area_zh":"交流功率","search_zh":"单相模拟和数字有功功率表 校准 — 交流功率 内部程序；在固定地点 (S) 交流功率 内部程序 在固定地点 (S) 40 Hz 至 500 Hz；PF = 1；1,3 V 至 750 V；0,005 A 至 150 A 内部程序 PP-LME-03 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"单相模拟和数字有功功率表","methodology_cs":"Kalibrace — Výkon AC","parameters_cs":[{"name":"40 Hz až 500 Hz; PF = 1; 1,3 V až 750 V; 0,005 A až 150 A","range":"6,5 mW to 112,5 kW","cmc":"0,15 %"}],"reference_cs":"Interní postupy PP-LME-03 PP-LME-04","regulatory_area_cs":"Výkon AC","search_cs":"Analogové a digitální jednofázové měřiče činného výkonu Kalibrace — Výkon AC Vnitřní postup; Ve stálé lokalitě (S) Výkon AC Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 500 Hz; PF = 1; 1,3 V až 750 V; 0,005 A až 150 A Interní postupy PP-LME-03 PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové a digitální jednofázové měřiče činného výkonu"},{"_id":"b02d1a7543af1186fd1611b4","lab_id":"6afa3b9a8989a133b76445c7","country":"PL","accr_number":"AP 024","accr_body":"PCA","test_object":"Kalibratory\nMierniki częstotliwości cyfrowe\nMultimetry","test_object_en":"Calibrators\nDigital frequency meters\nMultimeters","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"1 Hz do 1 kHz","cmc":"0,004 %"},{"name":"","range":"1 kHz do 130 MHz","cmc":"0,001 %"}],"parameters_en":[{"name":"","range":"1 Hz to 1 kHz","cmc":"0,004 %"},{"name":"","range":"1 kHz to 130 MHz","cmc":"0,001 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\n1 Hz do 1 kHz CMC 0,004 %\n1 kHz do 130 MHz CMC 0,001 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedury wewnętrzne PP-LME-03 PP-LME-04","norm_bases":["PP-LME-03","PP-LME-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kalibratory\nMierniki częstotliwości cyfrowe\nMultimetry Wzorcowanie — Częstotliwość\nZakres:\n1 Hz do 1 kHz CMC 0,004 %\n1 kHz do 130 MHz CMC 0,001 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedury wewnętrzne PP-LME-03 PP-LME-04 Kalibratory\nMierniki czestotliwosci cyfrowe\nMultimetry Wzorcowanie — Czestotliwosc\nZakres:\n1 Hz do 1 kHz CMC 0,004 %\n1 kHz do 130 MHz CMC 0,001 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedury wewnetrzne PP-LME-03 PP-LME-04","search_en":"Calibrators Digital frequency meters Multimeters Calibration — Frequency Internal procedure; At permanent location (S) Frequency Internal procedure At permanent location (S) Internal procedures PP-LME-03 PP-LME-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":42,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedures PP-LME-03 PP-LME-04","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"1 Hz bis 1 kHz","cmc":"0,004 %"},{"name":"","range":"1 kHz to 130 MHz","cmc":"0,001 %"}],"reference_de":"Interne Verfahren PP-LME-03 PP-LME-04","regulatory_area_de":"Frequenz","search_de":"Kalibratoren Digitale Frequenzmesser Multimeter Kalibrierung — Frequenz Internes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Am festen Standort (S) Interne Verfahren PP-LME-03 PP-LME-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nDigitale Frequenzmesser\nMultimeter","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"1 Hz to 1 kHz","cmc":"0,004 %"},{"name":"","range":"1 kHz to 130 MHz","cmc":"0,001 %"}],"reference_zh":"内部程序 PP-LME-03 PP-LME-04","regulatory_area_zh":"频率","search_zh":"校准器 数字频率计 万用表 校准 — 频率 内部程序；在固定地点 (S) 频率 内部程序 在固定地点 (S) 内部程序 PP-LME-03 PP-LME-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器\n数字频率计\n万用表","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"1 Hz to 1 kHz","cmc":"0,004 %"},{"name":"","range":"1 kHz to 130 MHz","cmc":"0,001 %"}],"reference_cs":"Interní postupy PP-LME-03 PP-LME-04","regulatory_area_cs":"Frekvence","search_cs":"Kalibrátory Digitální čítače kmitočtu Multimetry Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) Frekvence Vnitřní postup Ve stálé lokalitě (S) Interní postupy PP-LME-03 PP-LME-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nDigitální čítače kmitočtu\nMultimetry"}],"has_pdf":true}