🇵🇱 LabStand Sp. z o.o. PL

PCA AP 021 • Poznań, Poland • 30 calibration items

Metrology & calibration

LabStand Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 021 (Poznań, Poland). Its accreditation scope covers 30 calibration items in the following areas: Metrology & calibration. Calibrated items include: Electrical thermometers (data loggers), Electrical thermometers (including electronic), Conductometers, Dispensers. Most frequently used calibration principles: Internal procedure; At permanent location (S), At permanent location (S), At permanent location (S) and outside of it (P).

At a glance

  • Accreditation number: PCA AP 021
  • Calibration items in scope: 30
  • Types of calibrated items: 32
  • Calibration principles used: 12
  • City: Poznań, Poland
  • Valid until: 05-11-2028
Accreditation number
AP 021
Accreditation body
PCA
Address
ul. Grunwaldzka 114, 60-308 Poznań
City
Poznań, Poland
Division
Calibration Laboratory
Valid until
05-11-2028

What this laboratory calibrates (32)

Calibration principles (12)

Certificate information

Issue date
14.10.2026
Issue no.
27
Certificate date
01.06.2022
Accreditation cycle
14.10.2024 — 05.11.2028
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (30)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. and is expressed in measurand units. The measurement uncertainty value for CMC expressed as a percentage is the relative measurement uncertainty and refers to the percentage share in the measured value.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 pH meters Calibration — PH
pH — 0 to 14 · CMC 0,0014
PH
Internal procedure; Electrical method; At permanent location (S) PT 01/400
2 pH meters Calibration — PH
DC voltage — -2000 mV to 2000 mV · CMC 0,13 mV pH — 1 to 13 · CMC 0,01
PH
Internal procedure; Method using reference materials; At permanent location (S) PT 01/400
3 pH electrodes Calibration — PH
slope of the characteristic — 45,0 mV to 65,0 mV · CMC 0,25 mV electrode efficiency — 50,0 % to 110,0 % · CMC 0,3 % zero point (pH for E = 0 mV) — 2,00 to 10,00 · CMC 0,02
PH
Internal procedure; At permanent location (S) PT 01/300
4 Conductometers Calibration — Specific electrical conductivity (conductometry)
0,1 µS/cm to 1,99 µS/cm · CMC 0,001 µS/cm 2 µS/cm to 200 mS/cm · CMC 0,1 %
Specific electrical conductivity (conductometry)
Internal procedure; Electrical method; At permanent location (S) PT 01/700
5 Conductometers Calibration — Specific electrical conductivity (conductometry)
0,08 mS/cm to 0,15 mS/cm · CMC 0,4 % 0,15 mS/cm to 115 mS/cm · CMC 0,2 %
Specific electrical conductivity (conductometry)
Internal procedure; Method using reference materials; At permanent location (S) PT 01/700
6 Conductivity sensors Calibration — Specific electrical conductivity (conductometry)
0,01 cm⁻¹ to 11 cm⁻¹ · CMC 0,2 %
Specific electrical conductivity (conductometry)
Internal procedure; At permanent location (S) PT 01/800
7 Breath alcohol analyzer Calibration — Mass concentration (breath analysis)
0,00 mg/l do 0,40 mg/l · CMC 0,01 mg/l 0,41 mg/l do 1,00 mg/l · CMC 0,02 mg/l 1,01 mg/l to 1,50 mg/l · CMC 0,03 mg/l 1,51 mg/l to 2,00 mg/l · CMC 0,05 mg/l
Mass concentration (breath analysis)
Internal procedure; Mass concentration of ethanol in exhaled air (mg of ethanol in 1 l of air); At permanent location (S) PT 04/200 based on OIML R126-2:2021 A.1.1, A.2
8 Oxygen meters Calibration — Volume fraction, mass fraction (liquid analysis)
0 mg/l · CMC 0,02 mg/l 5 mg/l to 13 mg/l1) · CMC 0,11 mg/l 0 % · CMC 0,3 % 100 % · CMC 1,35 %
Volume fraction, mass fraction (liquid analysis)
At permanent location (S) PN-EN ISO 5814:2013
9 Redox electrodes Calibration — Redox potential
200 mV to 700 mV · CMC 5 mV
Redox potential
Value of the redox potential relative to the Ag/AgCl electrode (3 mol KCI); At permanent location (S) ASTM D1498-14
10 pH reference materials Calibration — Reference materials - measurement
1,00 to 8,00 · CMC 0,01 8,00 to 10,10 · CMC 0,02 10,1 to 12,5 · CMC 0,1
Reference materials - measurement
Internal procedure; At permanent location (S) PP 01/200
11 Viscosity reference materials Calibration — Reference materials - measurement
1 mm²/s to 140 mm²/s · CMC 0,2 % 1 mPa · s to 140 mPa · s · CMC 0,2 % 140 mm²/s to 2000 mm²/s · CMC 0,3 % 140 mPa · s to 2000 mPa · s · CMC 0,3 %
Reference materials - measurement
Internal procedure; At permanent location (S) PP 02/200 PP 02/201
12 Conductivity reference materials Calibration — Reference materials - measurement
0,0004 S/m to 12,0 S/m · CMC 0,4 %
Reference materials - measurement
Internal procedure; At permanent location (S) PP 07/200
13 Redox reference material Calibration — Reference materials - measurement
200 mV to 700 mV · CMC 5 mV
Reference materials - measurement
Value of the redox potential relative to the Ag/AgCl electrode (3 mol KCI); At permanent location (S) ASTM D1498-14
14 Pycnometers Calibration — Density (liquid)
volume — 10 cm³ to 51 cm³ · CMC 0,003 cm³ volume — 51 cm³ to 201 cm³ · CMC 0,01 cm³ volume — 202 cm³ to 2000 cm³ · CMC 0,3 cm³
Density (liquid)
At permanent location (S) PN-EN ISO 2811-1:2023-03
15 Glass capillary viscometers Calibration — Viscosity
0,001 mm²/s² to 10,5 mm²/s² · CMC 0,5 %
Viscosity
Internal procedure; At permanent location (S) PT 02/300
16 Rotational viscometers Calibration — Viscosity
1 mPa · s to 2000 mPa · s · CMC 2 % 2000 mPa · s to 15000 mPa · s · CMC 3 %
Viscosity
At permanent location (S) and outside of it (P) PN-EN ISO 2555:2018-07 DIN 53019-2:2001
17 Hygrometers
Thermohygrometers
Calibration — Relative humidity
temperature — 15 °C to 20 °C · CMC 0,1 °C relative humidity — 20 %rh to 30 %rh · CMC 0,7 %rh temperature — 20 °C to 40 °C · CMC 0,1 °C relative humidity — 20 %rh to 30 %rh · CMC 0,7 %rh temperature — 10 °C to 42 °C · CMC 0,1 °C relative humidity — 30 %rh to 85 %rh · CMC 0,7 %rh temperature — 7 °C to 10 °C · CMC 0,1 °C relative humidity — 30 %rh to 50 %rh · CMC 0,8 %rh temperature — 5 °C to 10 °C · CMC 0,1 °C relative humidity — 50 %rh to 85 %rh · CMC 0,8 %rh temperature — 42 °C to 50 °C · CMC 0,1 °C relative humidity — 20 %rh to 60 %rh · CMC 0,8 %rh
Relative humidity
Internal procedure; Indirect method Direct method; At permanent location (S) PT 09/100
18 Non-automatic electronic weighing instruments
Non-automatic mechanical weighing instruments
Calibration — Mass (scales)
up 1020 g · CMC 1,8 · 10⁻⁴ % 1020 g to 9000 g · CMC 4,6 · 10⁻⁴ % 9 kg to 31 kg · CMC 1,3 · 10⁻³ %
Mass (scales)
At permanent location (S) and outside of it (P) Euramet cg-18 v. 4.0
19 Digital manometers
Pressure gauges
Barometers
Calibration — Pressure
700 hPa to 1100 hPa · CMC 0,25 hPa
Pressure
At permanent location (S) Euramet cg-17 v. 4.1 point 5.2.1 point 5.2.2
20 Climatic chambers
Thermostatic chambers
Calibration — Temperature (electric thermometry)
-80 °C to 180 °C · CMC 0,3 °C2) 180 °C to 250 °C · CMC 1 °C2)
Temperature (electric thermometry)
At permanent location (S) and outside of it (P) Euramet cg-20 v. 5.0
21 Liquid baths Calibration — Temperature (electric thermometry)
-40 °C to 250 °C · CMC 0,3 °C
Temperature (electric thermometry)
At permanent location (S) and outside of it (P) Euramet cg-13 v. 4.0
22 Furnaces Calibration — Temperature (electric thermometry)
30 °C to 170 °C · CMC 0,5 °C 171 °C to 1100 °C · CMC 1,8 °C
Temperature (electric thermometry)
At permanent location (S) and outside of it (P) Euramet cg-13 v. 4.0
23 Electrical thermometers (including electronic)
Electrical thermometers (data loggers)
Calibration — Temperature (electric thermometry)
-40 °C to 80 °C · CMC 0,1 °C 80 °C to 180 °C · CMC 0,2 °C
Temperature (electric thermometry)
Internal procedure; Direct method Calibration in the climate chamber; At permanent location (S) PT 05/100
24 Electrical thermometers (including electronic)
Electrical thermometers (data loggers)
Calibration — Temperature (electric thermometry)
-80 °C to 180 °C · CMC 0,03 °C
Temperature (electric thermometry)
Internal procedure; Direct method Calibration in a liquid thermostat; At permanent location (S) PT 05/100
25 Electrical thermometers (including electronic)
Electrical thermometers (data loggers)
Calibration — Temperature (electric thermometry)
-100 °C to -80 °C · CMC 0,5 °C -80 °C to 30 °C · CMC 0,2 °C 30 °C to 250 °C · CMC 0,2 °C
Temperature (electric thermometry)
Internal procedure; Direct method Calibration in the temperature calibrator; At permanent location (S) and outside of it (P) PT 05/100
26 Electrical thermometers (including electronic)
Electrical thermometers (data loggers)
Calibration — Temperature (electric thermometry)
250°C to 660 °C · CMC 0,2 °C 660°C to 700 °C · CMC 0,8 °C 700°C to 1100 °C · CMC 2,1 °C
Temperature (electric thermometry)
Internal procedure; Direct method Calibration in the temperature calibrator; At permanent location (S) PT 05/100
27 Liquid in glass thermometers Calibration — Temperature (non-electric thermometry)
-40 °C to 180 °C · CMC 0,04 °C
Temperature (non-electric thermometry)
Internal procedure; At permanent location (S) PT 05/100
28 Pyrometers Calibration — Temperature (radiation thermometry)
-15 °C do 0 °C · CMC 1,6 °C 0 °C to 120 °C · CMC 1,4 °C 120 °C do 300 °C · CMC 2,6 °C 300 °C do 500 °C · CMC 2,8 °C
Temperature (radiation thermometry)
At permanent location (S) VDI/VDE 3511 Part 4.4
29 Piston pipettes
Piston burettes
Dispensers
Calibration — Volume
0,1 µl to 2,5 µl · CMC 0,025 µl 2,5 µl to 20 µl · CMC 0,040 µl 20 µl to 200 µl · CMC 0,30 µl 200 µl to 1000 µl · CMC 1,8 µl 1000 µl to 5000 µl · CMC 9 µl 5000 µl to 10000 µl · CMC 14 µl 10000 µl to 20000 µl · CMC 27 µl
Volume
At permanent location (S) PN-EN ISO 8655-6:2022-11
30 Piston burettes
Dispensers
Calibration — Volume
20000 µl to 50000 µl · CMC 35 µl
Volume
At permanent location (S) PN-EN ISO 8655-6:2022-11

Reference standards (24)

ASTM D1498-14
DIN 53019-2:2001
Euramet cg-13 v. 4.0
Euramet cg-17 v. 4.1
Euramet cg-18 v. 4.0
Euramet cg-20 v. 5.0
OIML R126-2:2021 A.1.1, A.2
PN-EN ISO 2555:2018-07
PN-EN ISO 2811-1:2023-03
PN-EN ISO 5814:2013
PN-EN ISO 8655-6:2022-11
PP 01/200
PP 02/200
PP 02/201
PP 07/200
PT 01/300
PT 01/400
PT 01/700
PT 01/800
PT 02/300
PT 04/200
PT 05/100
PT 09/100
VDI/VDE 3511 Part 4.4

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20021