{"lab":{"_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","imported_at":"2026-11-14T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Grunwaldzka 114, 60-308 Poznań","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"01.06.2022","city":"Poznań","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. and is expressed in measurand units. The measurement uncertainty value for CMC expressed as a percentage is the relative measurement uncertainty and refers to the percentage share in the measured value.","cycle_from":"14.10.2024","cycle_to":"05.11.2028","email_source":"PCA","en_official":true,"fields_of_testing":[{"codes":"3.01","pl":"pH","en":"pH","de":"pH","zh":"pH 值","cs":"pH"},{"codes":"3.02","pl":"przewodność elektryczna właściwa (konduktometria)","en":"specific electrical conductivity (conductometry)","de":"spezifische elektrische Leitfähigkeit (Konduktometrie)","zh":"电导率（电导测量）","cs":"měrná elektrická vodivost (konduktometrie)"},{"codes":"3.04","pl":"stężenie masowe (analiza wydechu)","en":"mass concentration (breath analysis)","de":"Massenkonzentration (Atemalkoholanalyse)","zh":"质量浓度（呼气分析）","cs":"hmotnostní koncentrace (analýza dechu)"},{"codes":"3.05","pl":"ułamek objętościowy, ułamek masowy (analiza cieczy)","en":"volume fraction, mass fraction (liquid analysis)","de":"Volumenanteil, Massenanteil (Flüssigkeitsanalyse)","zh":"体积分数、质量分数（液体分析）","cs":"objemový zlomek, hmotnostní zlomek (analýza kapalin)"},{"codes":"3.06","pl":"potencjał redoks","en":"redox potential","de":"Redoxpotential","zh":"氧化还原电位","cs":"redoxní potenciál"},{"codes":"5.02","pl":"gęstość (ciecz)","en":"density (liquid)","de":"Dichte (Flüssigkeit)","zh":"密度（液体）","cs":"hustota (kapalina)"},{"codes":"5.03","pl":"lepkość","en":"viscosity","de":"Viskosität","zh":"黏度","cs":"viskozita"},{"codes":"14.02","pl":"wilgotność względna","en":"relative humidity","de":"relative Feuchte","zh":"相对湿度","cs":"relativní vlhkost"},{"codes":"15.01","pl":"masa (wagi)","en":"mass (weight)","de":"Masse (Waagen)","zh":"质量（衡器）","cs":"hmotnost (váhy)"},{"codes":"17.01","pl":"ciśnienie","en":"pressure","de":"Druck","zh":"压力","cs":"tlak"},{"codes":"19.01","pl":"temperatura (termometria elektryczna)","en":"temperature (electrical thermometry)","de":"Temperatur (elektrische Thermometrie)","zh":"温度（电测温）","cs":"teplota (elektrická termometrie)"},{"codes":"19.02","pl":"temperatura (termometria nieelektryczna)","en":"Temperature (non-electric thermometry)","de":"Temperatur (nichtelektrische Thermometrie)","zh":"温度（非电测温）","cs":"teplota (neelektrická termometrie)"},{"codes":"19.03","pl":"temperatura (termometria radiacyjna)","en":"temperature (radiation thermometry)","de":"Temperatur (Strahlungsthermometrie)","zh":"温度（辐射测温）","cs":"teplota (radiační termometrie)"},{"codes":"20.01","pl":"objętość","en":"volume","de":"Volumen","zh":"体积","cs":"objem"},{"codes":"4.01","pl":"materiały odniesienia","en":"reference materials","de":"Referenzmaterialien","zh":"标准物质","cs":"referenční materiály"}],"has_en":true,"has_zh":true,"issue":{"no":"27","date":"14.10.2026"},"issue_date":"14.10.2026","issue_number":"27","lab_division":"Laboratorium Wzorcujące","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[16.8643301,52.3956624]},"map_coord":[52.3956624,16.8643301],"map_geo":"nominatim-street","methods_count":30,"name":"LabStand Sp. z o.o.","parse_date":"2026-11-14T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-14T12:00:00.000Z","pdf_files":["AP_021.pdf"],"scope_notes":[{"pl":"1) Jeden punkt pomiarowy odpowiadający 100 % nasycenia tlenem.","en":"1) One measuring point corresponding to 100 % oxygen saturation."},{"pl":"2) Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni pomiarowej.","en":"2) The measurement uncertainty value for CMC refers to a single point in the measurement space of the calibrated object."}],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: pH, przewodność elektryczna właściwa (konduktometria), stężenie masowe (analiza wydechu), ułamek objętościowy, ułamek masowy (analiza cieczy), potencjał redoks, gęstość (ciecz), lepkość, wilgotność względna, masa (wagi), ciśnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna), temperatura (termometria radiacyjna), objętość, materiały odniesienia. W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"labstand sp. z o.o. laboratorium wzorcujące ul. grunwaldzka 114, 60-308 poznań laboratorium wzorcujące. wielkości mierzone: ph, przewodność elektryczna właściwa (konduktometria), stężenie masowe (analiza wydechu), ułamek objętościowy, ułamek masowy (analiza cieczy), potencjał redoks, gęstość (ciecz), lepkość, wilgotność względna, masa (wagi), ciśnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna), temperatura (termometria radiacyjna), objętość, materiały odniesienia. w stałej lokalizacji (s) i/lub poza nią (p). ap 021 ap021 laboratorium wzorcujące wzorcowanie kalibracja ph specific electrical conductivity (conductometry) mass concentration (breath analysis) volume fraction, mass fraction (liquid analysis) redox potential density (liquid) viscosity relative humidity mass (weight) pressure temperature (electrical thermometry) temperature (non-electric thermometry) temperature (radiation thermometry) volume reference materials labstand sp. z o.o. laboratorium wzorcujace ul. grunwaldzka 114, 60-308 poznan laboratorium wzorcujace. wielkosci mierzone: ph, przewodnosc elektryczna wlasciwa (konduktometria), stezenie masowe (analiza wydechu), ulamek objetosciowy, ulamek masowy (analiza cieczy), potencjal redoks, gestosc (ciecz), lepkosc, wilgotnosc wzgledna, masa (wagi), cisnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna), temperatura (termometria radiacyjna), objetosc, materialy odniesienia. w stalej lokalizacji (s) i/lub poza nia (p). ap 021 ap021 laboratorium wzorcujace wzorcowanie kalibracja ph specific electrical conductivity (conductometry) mass concentration (breath analysis) volume fraction, mass fraction (liquid analysis) redox potential density (liquid) viscosity relative humidity mass (weight) pressure temperature (electrical thermometry) temperature (non-electric thermometry) temperature (radiation thermometry) volume reference materials","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20021,podmiot.html","source_pdf_sha256":"7a67c8ad9d2d83f27097d18b26ad9dba373076867dfd5444187cce8ec5599445","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/14/03301b2c229ce645d1a1268c9c8653f4/AP%20021.pdf","status":"active","updated_at":"2026-11-14T12:00:00.000Z","valid_from":"06-11-2000","valid_until":"05-11-2028","website":"www.labstand.com.pl","lab_division_en":"Calibration Laboratory","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"lab_division_de":"Kalibrierlaboratorium","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","lab_division_zh":"校准实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"lab_division_cs":"Kalibrační laboratoř","pelny_cs":true},"methods":[{"_id":"6db8359ca0727fa17265cdf3","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Pehametry","test_object_en":"pH meters","methodology":"Wzorcowanie — PH","methodology_en":"Calibration — PH","parameters":[{"name":"- pH","range":"0 do 14","cmc":"0,0014"}],"parameters_en":[{"name":"pH","range":"0 to 14","cmc":"0,0014"}],"technique":"Procedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S)","technique_en":"Internal procedure; Electrical method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda elektryczna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Electrical method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — PH\n- pH 0 do 14 CMC 0,0014\nProcedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S)","reference":"PT 01/400","norm_bases":["PT 01/400"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"PH","regulatory_area_en":"PH","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pehametry Wzorcowanie — PH\n- pH 0 do 14 CMC 0,0014\nProcedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S) PT 01/400 Pehametry Wzorcowanie — PH\n- pH 0 do 14 CMC 0,0014\nProcedura wewnetrzna; Metoda elektryczna; W stalej lokalizacji (S) PT 01/400","search_en":"pH meters Calibration — PH Internal procedure; Electrical method; At permanent location (S) PH Internal procedure Electrical method At permanent location (S) pH PT 01/400","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — PH","parameters_de":[{"name":"- pH","range":"0 to 14","cmc":"0,0014"}],"regulatory_area_de":"PH","search_de":"pH-Meter Kalibrierung — PH Internes Verfahren; Elektrisches Verfahren; Am festen Standort (S) PH Internes Verfahren Elektrisches Verfahren Am festen Standort (S) - pH PT 01/400","technique_de":"Internes Verfahren; Elektrisches Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Elektrisches Verfahren","Am festen Standort (S)"],"test_object_de":"pH-Meter","methodology_zh":"校准 — PH","parameters_zh":[{"name":"- pH","range":"0 to 14","cmc":"0,0014"}],"regulatory_area_zh":"PH","search_zh":"pH 计 校准 — PH 内部程序；电学法；在固定地点 (S) PH 内部程序 电学法 在固定地点 (S) - pH PT 01/400","technique_zh":"内部程序；电学法；在固定地点 (S)","techniques_zh":["内部程序","电学法","在固定地点 (S)"],"test_object_zh":"pH 计","methodology_cs":"Kalibrace — PH","parameters_cs":[{"name":"- pH","range":"0 to 14","cmc":"0,0014"}],"regulatory_area_cs":"PH","search_cs":"pH metry Kalibrace — PH Vnitřní postup; Elektrická metoda; Ve stálé lokalitě (S) PH Vnitřní postup Elektrická metoda Ve stálé lokalitě (S) - pH PT 01/400","technique_cs":"Vnitřní postup; Elektrická metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Elektrická metoda","Ve stálé lokalitě (S)"],"test_object_cs":"pH metry"},{"_id":"f1f566b8633b1b43ab632239","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Pehametry","test_object_en":"pH meters","methodology":"Wzorcowanie — PH","methodology_en":"Calibration — PH","parameters":[{"name":"- napięcie stałe","range":"-2000 mV do 2000 mV","cmc":"0,13 mV"},{"name":"- pH","range":"1 do 13","cmc":"0,01"}],"parameters_en":[{"name":"DC voltage","range":"-2000 mV to 2000 mV","cmc":"0,13 mV"},{"name":"pH","range":"1 to 13","cmc":"0,01"}],"technique":"Procedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Method using reference materials; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda z zastosowaniem materiałów odniesienia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Method using reference materials","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — PH\nZakres:\n- napięcie stałe -2000 mV do 2000 mV CMC 0,13 mV\n- pH 1 do 13 CMC 0,01\nProcedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S)","reference":"PT 01/400","norm_bases":["PT 01/400"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"PH","regulatory_area_en":"PH","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pehametry Wzorcowanie — PH\nZakres:\n- napięcie stałe -2000 mV do 2000 mV CMC 0,13 mV\n- pH 1 do 13 CMC 0,01\nProcedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S) PT 01/400 Pehametry Wzorcowanie — PH\nZakres:\n- napiecie stale -2000 mV do 2000 mV CMC 0,13 mV\n- pH 1 do 13 CMC 0,01\nProcedura wewnetrzna; Metoda z zastosowaniem materialow odniesienia; W stalej lokalizacji (S) PT 01/400","search_en":"pH meters Calibration — PH Internal procedure; Method using reference materials; At permanent location (S) PH Internal procedure Method using reference materials At permanent location (S) DC voltage pH PT 01/400","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — PH","parameters_de":[{"name":"- Gleichspannung","range":"-2000 mV to 2000 mV","cmc":"0,13 mV"},{"name":"- pH","range":"1 to 13","cmc":"0,01"}],"regulatory_area_de":"PH","search_de":"pH-Meter Kalibrierung — PH Internes Verfahren; Verfahren mit Referenzmaterialien; Am festen Standort (S) PH Internes Verfahren Verfahren mit Referenzmaterialien Am festen Standort (S) - Gleichspannung - pH PT 01/400","technique_de":"Internes Verfahren; Verfahren mit Referenzmaterialien; Am festen Standort (S)","techniques_de":["Internes Verfahren","Verfahren mit Referenzmaterialien","Am festen Standort (S)"],"test_object_de":"pH-Meter","methodology_zh":"校准 — PH","parameters_zh":[{"name":"- 直流电压","range":"-2000 mV to 2000 mV","cmc":"0,13 mV"},{"name":"- pH","range":"1 to 13","cmc":"0,01"}],"regulatory_area_zh":"PH","search_zh":"pH 计 校准 — PH 内部程序；使用参考物质的方法；在固定地点 (S) PH 内部程序 使用参考物质的方法 在固定地点 (S) - 直流电压 - pH PT 01/400","technique_zh":"内部程序；使用参考物质的方法；在固定地点 (S)","techniques_zh":["内部程序","使用参考物质的方法","在固定地点 (S)"],"test_object_zh":"pH 计","methodology_cs":"Kalibrace — PH","parameters_cs":[{"name":"- stejnosměrné napětí","range":"-2000 mV to 2000 mV","cmc":"0,13 mV"},{"name":"- pH","range":"1 to 13","cmc":"0,01"}],"regulatory_area_cs":"PH","search_cs":"pH metry Kalibrace — PH Vnitřní postup; Metoda s použitím referenčních materiálů; Ve stálé lokalitě (S) PH Vnitřní postup Metoda s použitím referenčních materiálů Ve stálé lokalitě (S) - stejnosměrné napětí - pH PT 01/400","technique_cs":"Vnitřní postup; Metoda s použitím referenčních materiálů; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Metoda s použitím referenčních materiálů","Ve stálé lokalitě (S)"],"test_object_cs":"pH metry"},{"_id":"8aa5db3e3b3fbf6419db8b96","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Elektrody pehametryczne","test_object_en":"pH electrodes","methodology":"Wzorcowanie — PH","methodology_en":"Calibration — PH","parameters":[{"name":"- nachylenie charakterystyki","range":"45,0 mV do 65,0 mV","cmc":"0,25 mV"},{"name":"- sprawność elektrody","range":"50,0 % do 110,0 %","cmc":"0,3 %"},{"name":"- punkt zerowy (pH dla E = 0 mV)","range":"2,00 do 10,00","cmc":"0,02"}],"parameters_en":[{"name":"slope of the characteristic","range":"45,0 mV to 65,0 mV","cmc":"0,25 mV"},{"name":"electrode efficiency","range":"50,0 % to 110,0 %","cmc":"0,3 %"},{"name":"zero point (pH for E = 0 mV)","range":"2,00 to 10,00","cmc":"0,02"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — PH\nZakres:\n- nachylenie charakterystyki 45,0 mV do 65,0 mV CMC 0,25 mV\n- sprawność elektrody 50,0 % do 110,0 % CMC 0,3 %\n- punkt zerowy (pH dla E = 0 mV) 2,00 do 10,00 CMC 0,02\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PT 01/300","norm_bases":["PT 01/300"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"PH","regulatory_area_en":"PH","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Elektrody pehametryczne Wzorcowanie — PH\nZakres:\n- nachylenie charakterystyki 45,0 mV do 65,0 mV CMC 0,25 mV\n- sprawność elektrody 50,0 % do 110,0 % CMC 0,3 %\n- punkt zerowy (pH dla E = 0 mV) 2,00 do 10,00 CMC 0,02\nProcedura wewnętrzna; W stałej lokalizacji (S) PT 01/300 Elektrody pehametryczne Wzorcowanie — PH\nZakres:\n- nachylenie charakterystyki 45,0 mV do 65,0 mV CMC 0,25 mV\n- sprawnosc elektrody 50,0 % do 110,0 % CMC 0,3 %\n- punkt zerowy (pH dla E = 0 mV) 2,00 do 10,00 CMC 0,02\nProcedura wewnetrzna; W stalej lokalizacji (S) PT 01/300","search_en":"pH electrodes Calibration — PH Internal procedure; At permanent location (S) PH Internal procedure At permanent location (S) slope of the characteristic electrode efficiency zero point (pH for E = 0 mV) PT 01/300","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — PH","parameters_de":[{"name":"- Steilheit der Kennlinie","range":"45,0 mV to 65,0 mV","cmc":"0,25 mV"},{"name":"- Elektrodenwirkungsgrad","range":"50,0 % to 110,0 %","cmc":"0,3 %"},{"name":"- Nullpunkt (pH für E = 0 mV)","range":"2,00 to 10,00","cmc":"0,02"}],"regulatory_area_de":"PH","search_de":"pH-Elektroden Kalibrierung — PH Internes Verfahren; Am festen Standort (S) PH Internes Verfahren Am festen Standort (S) - Steilheit der Kennlinie - Elektrodenwirkungsgrad - Nullpunkt (pH für E = 0 mV) PT 01/300","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"pH-Elektroden","methodology_zh":"校准 — PH","parameters_zh":[{"name":"- 特性曲线斜率","range":"45,0 mV to 65,0 mV","cmc":"0,25 mV"},{"name":"- 电极效率","range":"50,0 % to 110,0 %","cmc":"0,3 %"},{"name":"- 零点（E = 0 mV时的pH）","range":"2,00 to 10,00","cmc":"0,02"}],"regulatory_area_zh":"PH","search_zh":"pH电极 校准 — PH 内部程序；在固定地点 (S) PH 内部程序 在固定地点 (S) - 特性曲线斜率 - 电极效率 - 零点（E = 0 mV时的pH） PT 01/300","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"pH电极","methodology_cs":"Kalibrace — PH","parameters_cs":[{"name":"- strmost charakteristiky","range":"45,0 mV to 65,0 mV","cmc":"0,25 mV"},{"name":"- účinnost elektrody","range":"50,0 % to 110,0 %","cmc":"0,3 %"},{"name":"- nulový bod (pH pro E = 0 mV)","range":"2,00 to 10,00","cmc":"0,02"}],"regulatory_area_cs":"PH","search_cs":"pH elektrody Kalibrace — PH Vnitřní postup; Ve stálé lokalitě (S) PH Vnitřní postup Ve stálé lokalitě (S) - strmost charakteristiky - účinnost elektrody - nulový bod (pH pro E = 0 mV) PT 01/300","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"pH elektrody"},{"_id":"009a0cdc2a23617ce89ae1b5","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Konduktometry","test_object_en":"Conductometers","methodology":"Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)","methodology_en":"Calibration — Specific electrical conductivity (conductometry)","parameters":[{"name":"","range":"0,1 µS/cm do 1,99 µS/cm","cmc":"0,001 µS/cm"},{"name":"","range":"2 µS/cm do 200 mS/cm","cmc":"0,1 %"}],"parameters_en":[{"name":"","range":"0,1 µS/cm to 1,99 µS/cm","cmc":"0,001 µS/cm"},{"name":"","range":"2 µS/cm to 200 mS/cm","cmc":"0,1 %"}],"technique":"Procedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S)","technique_en":"Internal procedure; Electrical method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda elektryczna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Electrical method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)\nZakres:\n0,1 µS/cm do 1,99 µS/cm CMC 0,001 µS/cm\n2 µS/cm do 200 mS/cm CMC 0,1 %\nProcedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S)","reference":"PT 01/700","norm_bases":["PT 01/700"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Przewodność elektryczna właściwa (konduktometria)","regulatory_area_en":"Specific electrical conductivity (conductometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Konduktometry Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)\nZakres:\n0,1 µS/cm do 1,99 µS/cm CMC 0,001 µS/cm\n2 µS/cm do 200 mS/cm CMC 0,1 %\nProcedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S) PT 01/700 Konduktometry Wzorcowanie — Przewodnosc elektryczna wlasciwa (konduktometria)\nZakres:\n0,1 µS/cm do 1,99 µS/cm CMC 0,001 µS/cm\n2 µS/cm do 200 mS/cm CMC 0,1 %\nProcedura wewnetrzna; Metoda elektryczna; W stalej lokalizacji (S) PT 01/700","search_en":"Conductometers Calibration — Specific electrical conductivity (conductometry) Internal procedure; Electrical method; At permanent location (S) Specific electrical conductivity (conductometry) Internal procedure Electrical method At permanent location (S) PT 01/700","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Elektrische Leitfähigkeit (Konduktometrie)","parameters_de":[{"name":"","range":"0,1 µS/cm to 1,99 µS/cm","cmc":"0,001 µS/cm"},{"name":"","range":"2 µS/cm to 200 mS/cm","cmc":"0,1 %"}],"regulatory_area_de":"Spezifische elektrische Leitfähigkeit (Konduktometrie)","search_de":"Leitfähigkeitsmessgeräte Kalibrierung — Elektrische Leitfähigkeit (Konduktometrie) Internes Verfahren; Elektrisches Verfahren; Am festen Standort (S) Spezifische elektrische Leitfähigkeit (Konduktometrie) Internes Verfahren Elektrisches Verfahren Am festen Standort (S) PT 01/700","technique_de":"Internes Verfahren; Elektrisches Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Elektrisches Verfahren","Am festen Standort (S)"],"test_object_de":"Leitfähigkeitsmessgeräte","methodology_zh":"校准 — 电导率（电导法）","parameters_zh":[{"name":"","range":"0,1 µS/cm to 1,99 µS/cm","cmc":"0,001 µS/cm"},{"name":"","range":"2 µS/cm to 200 mS/cm","cmc":"0,1 %"}],"regulatory_area_zh":"电导率（电导法）","search_zh":"电导率仪 校准 — 电导率（电导法） 内部程序；电学法；在固定地点 (S) 电导率（电导法） 内部程序 电学法 在固定地点 (S) PT 01/700","technique_zh":"内部程序；电学法；在固定地点 (S)","techniques_zh":["内部程序","电学法","在固定地点 (S)"],"test_object_zh":"电导率仪","methodology_cs":"Kalibrace — Měrná elektrická vodivost (konduktometrie)","parameters_cs":[{"name":"","range":"0,1 µS/cm to 1,99 µS/cm","cmc":"0,001 µS/cm"},{"name":"","range":"2 µS/cm to 200 mS/cm","cmc":"0,1 %"}],"regulatory_area_cs":"Měrná elektrická vodivost (konduktometrie)","search_cs":"Konduktometry Kalibrace — Měrná elektrická vodivost (konduktometrie) Vnitřní postup; Elektrická metoda; Ve stálé lokalitě (S) Měrná elektrická vodivost (konduktometrie) Vnitřní postup Elektrická metoda Ve stálé lokalitě (S) PT 01/700","technique_cs":"Vnitřní postup; Elektrická metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Elektrická metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Konduktometry"},{"_id":"04b89c546da8c5ba08a089ac","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Konduktometry","test_object_en":"Conductometers","methodology":"Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)","methodology_en":"Calibration — Specific electrical conductivity (conductometry)","parameters":[{"name":"","range":"0,08 mS/cm do 0,15 mS/cm","cmc":"0,4 %"},{"name":"","range":"0,15 mS/cm do 115 mS/cm","cmc":"0,2 %"}],"parameters_en":[{"name":"","range":"0,08 mS/cm to 0,15 mS/cm","cmc":"0,4 %"},{"name":"","range":"0,15 mS/cm to 115 mS/cm","cmc":"0,2 %"}],"technique":"Procedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Method using reference materials; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda z zastosowaniem materiałów odniesienia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Method using reference materials","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)\nZakres:\n0,08 mS/cm do 0,15 mS/cm CMC 0,4 %\n0,15 mS/cm do 115 mS/cm CMC 0,2 %\nProcedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S)","reference":"PT 01/700","norm_bases":["PT 01/700"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Przewodność elektryczna właściwa (konduktometria)","regulatory_area_en":"Specific electrical conductivity (conductometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Konduktometry Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)\nZakres:\n0,08 mS/cm do 0,15 mS/cm CMC 0,4 %\n0,15 mS/cm do 115 mS/cm CMC 0,2 %\nProcedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S) PT 01/700 Konduktometry Wzorcowanie — Przewodnosc elektryczna wlasciwa (konduktometria)\nZakres:\n0,08 mS/cm do 0,15 mS/cm CMC 0,4 %\n0,15 mS/cm do 115 mS/cm CMC 0,2 %\nProcedura wewnetrzna; Metoda z zastosowaniem materialow odniesienia; W stalej lokalizacji (S) PT 01/700","search_en":"Conductometers Calibration — Specific electrical conductivity (conductometry) Internal procedure; Method using reference materials; At permanent location (S) Specific electrical conductivity (conductometry) Internal procedure Method using reference materials At permanent location (S) PT 01/700","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Elektrische Leitfähigkeit (Konduktometrie)","parameters_de":[{"name":"","range":"0,08 mS/cm to 0,15 mS/cm","cmc":"0,4 %"},{"name":"","range":"0,15 mS/cm to 115 mS/cm","cmc":"0,2 %"}],"regulatory_area_de":"Spezifische elektrische Leitfähigkeit (Konduktometrie)","search_de":"Leitfähigkeitsmessgeräte Kalibrierung — Elektrische Leitfähigkeit (Konduktometrie) Internes Verfahren; Verfahren mit Referenzmaterialien; Am festen Standort (S) Spezifische elektrische Leitfähigkeit (Konduktometrie) Internes Verfahren Verfahren mit Referenzmaterialien Am festen Standort (S) PT 01/700","technique_de":"Internes Verfahren; Verfahren mit Referenzmaterialien; Am festen Standort (S)","techniques_de":["Internes Verfahren","Verfahren mit Referenzmaterialien","Am festen Standort (S)"],"test_object_de":"Leitfähigkeitsmessgeräte","methodology_zh":"校准 — 电导率（电导法）","parameters_zh":[{"name":"","range":"0,08 mS/cm to 0,15 mS/cm","cmc":"0,4 %"},{"name":"","range":"0,15 mS/cm to 115 mS/cm","cmc":"0,2 %"}],"regulatory_area_zh":"电导率（电导法）","search_zh":"电导率仪 校准 — 电导率（电导法） 内部程序；使用参考物质的方法；在固定地点 (S) 电导率（电导法） 内部程序 使用参考物质的方法 在固定地点 (S) PT 01/700","technique_zh":"内部程序；使用参考物质的方法；在固定地点 (S)","techniques_zh":["内部程序","使用参考物质的方法","在固定地点 (S)"],"test_object_zh":"电导率仪","methodology_cs":"Kalibrace — Měrná elektrická vodivost (konduktometrie)","parameters_cs":[{"name":"","range":"0,08 mS/cm to 0,15 mS/cm","cmc":"0,4 %"},{"name":"","range":"0,15 mS/cm to 115 mS/cm","cmc":"0,2 %"}],"regulatory_area_cs":"Měrná elektrická vodivost (konduktometrie)","search_cs":"Konduktometry Kalibrace — Měrná elektrická vodivost (konduktometrie) Vnitřní postup; Metoda s použitím referenčních materiálů; Ve stálé lokalitě (S) Měrná elektrická vodivost (konduktometrie) Vnitřní postup Metoda s použitím referenčních materiálů Ve stálé lokalitě (S) PT 01/700","technique_cs":"Vnitřní postup; Metoda s použitím referenčních materiálů; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Metoda s použitím referenčních materiálů","Ve stálé lokalitě (S)"],"test_object_cs":"Konduktometry"},{"_id":"ed5c90ec360e7aac8bdec957","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Czujniki konduktometryczne","test_object_en":"Conductivity sensors","methodology":"Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)","methodology_en":"Calibration — Specific electrical conductivity (conductometry)","parameters":[{"name":"","range":"0,01 cm⁻¹ do 11 cm⁻¹","cmc":"0,2 %"}],"parameters_en":[{"name":"","range":"0,01 cm⁻¹ to 11 cm⁻¹","cmc":"0,2 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)\n0,01 cm⁻¹ do 11 cm⁻¹ CMC 0,2 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PT 01/800","norm_bases":["PT 01/800"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Przewodność elektryczna właściwa (konduktometria)","regulatory_area_en":"Specific electrical conductivity (conductometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki konduktometryczne Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)\n0,01 cm⁻¹ do 11 cm⁻¹ CMC 0,2 %\nProcedura wewnętrzna; W stałej lokalizacji (S) PT 01/800 Czujniki konduktometryczne Wzorcowanie — Przewodnosc elektryczna wlasciwa (konduktometria)\n0,01 cm⁻¹ do 11 cm⁻¹ CMC 0,2 %\nProcedura wewnetrzna; W stalej lokalizacji (S) PT 01/800","search_en":"Conductivity sensors Calibration — Specific electrical conductivity (conductometry) Internal procedure; At permanent location (S) Specific electrical conductivity (conductometry) Internal procedure At permanent location (S) PT 01/800","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Elektrische Leitfähigkeit (Konduktometrie)","parameters_de":[{"name":"","range":"0,01 cm⁻¹ to 11 cm⁻¹","cmc":"0,2 %"}],"regulatory_area_de":"Spezifische elektrische Leitfähigkeit (Konduktometrie)","search_de":"Leitfähigkeitssensoren Kalibrierung — Elektrische Leitfähigkeit (Konduktometrie) Internes Verfahren; Am festen Standort (S) Spezifische elektrische Leitfähigkeit (Konduktometrie) Internes Verfahren Am festen Standort (S) PT 01/800","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Leitfähigkeitssensoren","methodology_zh":"校准 — 电导率（电导法）","parameters_zh":[{"name":"","range":"0,01 cm⁻¹ to 11 cm⁻¹","cmc":"0,2 %"}],"regulatory_area_zh":"电导率（电导法）","search_zh":"电导率传感器 校准 — 电导率（电导法） 内部程序；在固定地点 (S) 电导率（电导法） 内部程序 在固定地点 (S) PT 01/800","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电导率传感器","methodology_cs":"Kalibrace — Měrná elektrická vodivost (konduktometrie)","parameters_cs":[{"name":"","range":"0,01 cm⁻¹ to 11 cm⁻¹","cmc":"0,2 %"}],"regulatory_area_cs":"Měrná elektrická vodivost (konduktometrie)","search_cs":"Konduktometrické senzory Kalibrace — Měrná elektrická vodivost (konduktometrie) Vnitřní postup; Ve stálé lokalitě (S) Měrná elektrická vodivost (konduktometrie) Vnitřní postup Ve stálé lokalitě (S) PT 01/800","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Konduktometrické senzory"},{"_id":"1008cdec7075beb2d0f08405","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Analizatory wydechu","test_object_en":"Breath alcohol analyzer","methodology":"Wzorcowanie — Stężenie masowe (analiza wydechu)","methodology_en":"Calibration — Mass concentration (breath analysis)","parameters":[{"name":"","range":"0,00 mg/l do 0,40 mg/l","cmc":"0,01 mg/l"},{"name":"","range":"0,41 mg/l do 1,00 mg/l","cmc":"0,02 mg/l"},{"name":"","range":"1,01 mg/l do 1,50 mg/l","cmc":"0,03 mg/l"},{"name":"","range":"1,51 mg/l do 2,00 mg/l","cmc":"0,05 mg/l"}],"parameters_en":[{"name":"","range":"0,00 mg/l do 0,40 mg/l","cmc":"0,01 mg/l"},{"name":"","range":"0,41 mg/l do 1,00 mg/l","cmc":"0,02 mg/l"},{"name":"","range":"1,01 mg/l to 1,50 mg/l","cmc":"0,03 mg/l"},{"name":"","range":"1,51 mg/l to 2,00 mg/l","cmc":"0,05 mg/l"}],"technique":"Procedura wewnętrzna; Stężenie masowe etanolu w wydychanym powietrzu (mg etanolu w 1 l powietrza); W stałej lokalizacji (S)","technique_en":"Internal procedure; Mass concentration of ethanol in exhaled air (mg of ethanol in 1 l of air); At permanent location (S)","techniques":["Procedura wewnętrzna","Stężenie masowe etanolu w wydychanym powietrzu (mg etanolu w 1 l powietrza)","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Mass concentration of ethanol in exhaled air (mg of ethanol in 1 l of air)","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Stężenie masowe (analiza wydechu)\nZakres:\n0,00 mg/l do 0,40 mg/l CMC 0,01 mg/l\n0,41 mg/l do 1,00 mg/l CMC 0,02 mg/l\n1,01 mg/l do 1,50 mg/l CMC 0,03 mg/l\n1,51 mg/l do 2,00 mg/l CMC 0,05 mg/l\nProcedura wewnętrzna; Stężenie masowe etanolu w wydychanym powietrzu (mg etanolu w 1 l powietrza); W stałej lokalizacji (S)","reference":"PT 04/200 w oparciu o OIML R126-2:2021 A.1.1, A.2","norm_bases":["PT 04/200","OIML R126-2:2021 A.1.1, A.2"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Stężenie masowe (analiza wydechu)","regulatory_area_en":"Mass concentration (breath analysis)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Analizatory wydechu Wzorcowanie — Stężenie masowe (analiza wydechu)\nZakres:\n0,00 mg/l do 0,40 mg/l CMC 0,01 mg/l\n0,41 mg/l do 1,00 mg/l CMC 0,02 mg/l\n1,01 mg/l do 1,50 mg/l CMC 0,03 mg/l\n1,51 mg/l do 2,00 mg/l CMC 0,05 mg/l\nProcedura wewnętrzna; Stężenie masowe etanolu w wydychanym powietrzu (mg etanolu w 1 l powietrza); W stałej lokalizacji (S) PT 04/200 w oparciu o OIML R126-2:2021 A.1.1, A.2 Analizatory wydechu Wzorcowanie — Stezenie masowe (analiza wydechu)\nZakres:\n0,00 mg/l do 0,40 mg/l CMC 0,01 mg/l\n0,41 mg/l do 1,00 mg/l CMC 0,02 mg/l\n1,01 mg/l do 1,50 mg/l CMC 0,03 mg/l\n1,51 mg/l do 2,00 mg/l CMC 0,05 mg/l\nProcedura wewnetrzna; Stezenie masowe etanolu w wydychanym powietrzu (mg etanolu w 1 l powietrza); W stalej lokalizacji (S) PT 04/200 w oparciu o OIML R126-2:2021 A.1.1, A.2","search_en":"Breath alcohol analyzer Calibration — Mass concentration (breath analysis) Internal procedure; Mass concentration of ethanol in exhaled air (mg of ethanol in 1 l of air); At permanent location (S) Mass concentration (breath analysis) Internal procedure Mass concentration of ethanol in exhaled air (mg of ethanol in 1 l of air) At permanent location (S) PT 04/200 based on OIML R126-2:2021 A.1.1, A.2","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT 04/200 based on OIML R126-2:2021 A.1.1, A.2","methodology_de":"Kalibrierung — Massenkonzentration (Atemanalyse)","parameters_de":[{"name":"","range":"0,00 mg/l do 0,40 mg/l","cmc":"0,01 mg/l"},{"name":"","range":"0,41 mg/l do 1,00 mg/l","cmc":"0,02 mg/l"},{"name":"","range":"1,01 mg/l bis 1,50 mg/l","cmc":"0,03 mg/l"},{"name":"","range":"1,51 mg/l bis 2,00 mg/l","cmc":"0,05 mg/l"}],"reference_de":"PT 04/200 auf Grundlage von OIML R126-2:2021 A.1.1, A.2","regulatory_area_de":"Massenkonzentration (Atemanalyse)","search_de":"Atemalkoholmessgeräte Kalibrierung — Massenkonzentration (Atemanalyse) Internes Verfahren; Massenkonzentration von Ethanol in der Ausatemluft (mg Ethanol in 1 l Luft); Am festen Standort (S) Massenkonzentration (Atemanalyse) Internes Verfahren Massenkonzentration von Ethanol in der Ausatemluft (mg Ethanol in 1 l Luft) Am festen Standort (S) PT 04/200 auf Grundlage von OIML R126-2:2021 A.1.1, A.2","technique_de":"Internes Verfahren; Massenkonzentration von Ethanol in der Ausatemluft (mg Ethanol in 1 l Luft); Am festen Standort (S)","techniques_de":["Internes Verfahren","Massenkonzentration von Ethanol in der Ausatemluft (mg Ethanol in 1 l Luft)","Am festen Standort (S)"],"test_object_de":"Atemalkoholmessgeräte","methodology_zh":"校准 — 质量浓度（呼气分析）","parameters_zh":[{"name":"","range":"0,00 mg/l do 0,40 mg/l","cmc":"0,01 mg/l"},{"name":"","range":"0,41 mg/l do 1,00 mg/l","cmc":"0,02 mg/l"},{"name":"","range":"1,01 mg/l 至 1,50 mg/l","cmc":"0,03 mg/l"},{"name":"","range":"1,51 mg/l 至 2,00 mg/l","cmc":"0,05 mg/l"}],"reference_zh":"PT 04/200 依据OIML R126-2:2021 A.1.1, A.2","regulatory_area_zh":"质量浓度（呼气分析）","search_zh":"呼气分析仪 校准 — 质量浓度（呼气分析） 内部程序；呼出气体中乙醇质量浓度（每 1 l 空气中乙醇的 mg 数）；在固定地点 (S) 质量浓度（呼气分析） 内部程序 呼出气体中乙醇质量浓度（每 1 l 空气中乙醇的 mg 数） 在固定地点 (S) PT 04/200 依据OIML R126-2:2021 A.1.1, A.2","technique_zh":"内部程序；呼出气体中乙醇质量浓度（每 1 l 空气中乙醇的 mg 数）；在固定地点 (S)","techniques_zh":["内部程序","呼出气体中乙醇质量浓度（每 1 l 空气中乙醇的 mg 数）","在固定地点 (S)"],"test_object_zh":"呼气分析仪","methodology_cs":"Kalibrace — Hmotnostní koncentrace (analýza dechu)","parameters_cs":[{"name":"","range":"0,00 mg/l do 0,40 mg/l","cmc":"0,01 mg/l"},{"name":"","range":"0,41 mg/l do 1,00 mg/l","cmc":"0,02 mg/l"},{"name":"","range":"1,01 mg/l do 1,50 mg/l","cmc":"0,03 mg/l"},{"name":"","range":"1,51 mg/l do 2,00 mg/l","cmc":"0,05 mg/l"}],"reference_cs":"PT 04/200 na základě OIML R126-2:2021 A.1.1, A.2","regulatory_area_cs":"Hmotnostní koncentrace (analýza dechu)","search_cs":"Analyzátory dechu Kalibrace — Hmotnostní koncentrace (analýza dechu) Vnitřní postup; Hmotnostní koncentrace ethanolu ve vydechovaném vzduchu (mg ethanolu v 1 l vzduchu); Ve stálé lokalitě (S) Hmotnostní koncentrace (analýza dechu) Vnitřní postup Hmotnostní koncentrace ethanolu ve vydechovaném vzduchu (mg ethanolu v 1 l vzduchu) Ve stálé lokalitě (S) PT 04/200 na základě OIML R126-2:2021 A.1.1, A.2","technique_cs":"Vnitřní postup; Hmotnostní koncentrace ethanolu ve vydechovaném vzduchu (mg ethanolu v 1 l vzduchu); Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Hmotnostní koncentrace ethanolu ve vydechovaném vzduchu (mg ethanolu v 1 l vzduchu)","Ve stálé lokalitě (S)"],"test_object_cs":"Analyzátory dechu"},{"_id":"951267ea81db8f38549971ee","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Tlenomierze","test_object_en":"Oxygen meters","methodology":"Wzorcowanie — Ułamek objętościowy, ułamek masowy (analiza cieczy)","methodology_en":"Calibration — Volume fraction, mass fraction (liquid analysis)","parameters":[{"name":"","range":"0 mg/l","cmc":"0,02 mg/l"},{"name":"","range":"5 mg/l do 13 mg/l1)","cmc":"0,11 mg/l"},{"name":"","range":"0 %","cmc":"0,3 %"},{"name":"","range":"100 %","cmc":"1,35 %"}],"parameters_en":[{"name":"","range":"0 mg/l","cmc":"0,02 mg/l"},{"name":"","range":"5 mg/l to 13 mg/l1)","cmc":"0,11 mg/l"},{"name":"","range":"0 %","cmc":"0,3 %"},{"name":"","range":"100 %","cmc":"1,35 %"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ułamek objętościowy, ułamek masowy (analiza cieczy)\nZakres:\n0 mg/l CMC 0,02 mg/l\n5 mg/l do 13 mg/l1) CMC 0,11 mg/l\n0 % CMC 0,3 %\n100 % CMC 1,35 %\nW stałej lokalizacji (S)","reference":"PN-EN ISO 5814:2013","norm_bases":["PN-EN ISO 5814:2013"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ułamek objętościowy, ułamek masowy (analiza cieczy)","regulatory_area_en":"Volume fraction, mass fraction (liquid analysis)","outside_premises":false,"location_of_activity":"S","note":"1) Jeden punkt pomiarowy odpowiadający 100 % nasycenia tlenem.","note_en":"1) One measuring point corresponding to 100 % oxygen saturation.","search_text":"Tlenomierze Wzorcowanie — Ułamek objętościowy, ułamek masowy (analiza cieczy)\nZakres:\n0 mg/l CMC 0,02 mg/l\n5 mg/l do 13 mg/l1) CMC 0,11 mg/l\n0 % CMC 0,3 %\n100 % CMC 1,35 %\nW stałej lokalizacji (S) PN-EN ISO 5814:2013 Tlenomierze Wzorcowanie — Ulamek objetosciowy, ulamek masowy (analiza cieczy)\nZakres:\n0 mg/l CMC 0,02 mg/l\n5 mg/l do 13 mg/l1) CMC 0,11 mg/l\n0 % CMC 0,3 %\n100 % CMC 1,35 %\nW stalej lokalizacji (S) PN-EN ISO 5814:2013","search_en":"Oxygen meters Calibration — Volume fraction, mass fraction (liquid analysis) At permanent location (S) Volume fraction, mass fraction (liquid analysis) At permanent location (S) PN-EN ISO 5814:2013","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Volumenanteil, Massenanteil (Flüssigkeitsanalyse)","parameters_de":[{"name":"","range":"0 mg/l","cmc":"0,02 mg/l"},{"name":"","range":"5 mg/l to 13 mg/l1)","cmc":"0,11 mg/l"},{"name":"","range":"0 %","cmc":"0,3 %"},{"name":"","range":"100 %","cmc":"1,35 %"}],"regulatory_area_de":"Volumenanteil, Massenanteil (Flüssigkeitsanalyse)","search_de":"Sauerstoffmessgeräte Kalibrierung — Volumenanteil, Massenanteil (Flüssigkeitsanalyse) Am festen Standort (S) Volumenanteil, Massenanteil (Flüssigkeitsanalyse) Am festen Standort (S) PN-EN ISO 5814:2013","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Sauerstoffmessgeräte","methodology_zh":"校准 — 体积分数、质量分数（液体分析）","parameters_zh":[{"name":"","range":"0 mg/l","cmc":"0,02 mg/l"},{"name":"","range":"5 mg/l to 13 mg/l1)","cmc":"0,11 mg/l"},{"name":"","range":"0 %","cmc":"0,3 %"},{"name":"","range":"100 %","cmc":"1,35 %"}],"regulatory_area_zh":"体积分数、质量分数（液体分析）","search_zh":"测氧仪 校准 — 体积分数、质量分数（液体分析） 在固定地点 (S) 体积分数、质量分数（液体分析） 在固定地点 (S) PN-EN ISO 5814:2013","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"测氧仪","methodology_cs":"Kalibrace — Objemový zlomek, hmotnostní zlomek (analýza kapalin)","parameters_cs":[{"name":"","range":"0 mg/l","cmc":"0,02 mg/l"},{"name":"","range":"5 mg/l to 13 mg/l1)","cmc":"0,11 mg/l"},{"name":"","range":"0 %","cmc":"0,3 %"},{"name":"","range":"100 %","cmc":"1,35 %"}],"regulatory_area_cs":"Objemový zlomek, hmotnostní zlomek (analýza kapalin)","search_cs":"Oxymetry Kalibrace — Objemový zlomek, hmotnostní zlomek (analýza kapalin) Ve stálé lokalitě (S) Objemový zlomek, hmotnostní zlomek (analýza kapalin) Ve stálé lokalitě (S) PN-EN ISO 5814:2013","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Oxymetry"},{"_id":"f5229412259610b422199cd1","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Elektrody redoks","test_object_en":"Redox electrodes","methodology":"Wzorcowanie — Potencjał redoks","methodology_en":"Calibration — Redox potential","parameters":[{"name":"","range":"200 mV do 700 mV","cmc":"5 mV"}],"parameters_en":[{"name":"","range":"200 mV to 700 mV","cmc":"5 mV"}],"technique":"Wartość potencjału redoks względem elektrody Ag/AgCl (3 mol KCI); W stałej lokalizacji (S)","technique_en":"Value of the redox potential relative to the Ag/AgCl electrode (3 mol KCI); At permanent location (S)","techniques":["Wartość potencjału redoks względem elektrody Ag/AgCl (3 mol KCI)","W stałej lokalizacji (S)"],"techniques_en":["Value of the redox potential relative to the Ag/AgCl electrode (3 mol KCI)","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Potencjał redoks\n200 mV do 700 mV CMC 5 mV\nWartość potencjału redoks względem elektrody Ag/AgCl (3 mol KCI); W stałej lokalizacji (S)","reference":"ASTM D1498-14","norm_bases":["ASTM D1498-14"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Potencjał redoks","regulatory_area_en":"Redox potential","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Elektrody redoks Wzorcowanie — Potencjał redoks\n200 mV do 700 mV CMC 5 mV\nWartość potencjału redoks względem elektrody Ag/AgCl (3 mol KCI); W stałej lokalizacji (S) ASTM D1498-14 Elektrody redoks Wzorcowanie — Potencjal redoks\n200 mV do 700 mV CMC 5 mV\nWartosc potencjalu redoks wzgledem elektrody Ag/AgCl (3 mol KCI); W stalej lokalizacji (S) ASTM D1498-14","search_en":"Redox electrodes Calibration — Redox potential Value of the redox potential relative to the Ag/AgCl electrode (3 mol KCI); At permanent location (S) Redox potential Value of the redox potential relative to the Ag/AgCl electrode (3 mol KCI) At permanent location (S) ASTM D1498-14","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Redoxpotential","parameters_de":[{"name":"","range":"200 mV to 700 mV","cmc":"5 mV"}],"regulatory_area_de":"Redoxpotential","search_de":"Redoxelektroden Kalibrierung — Redoxpotential Wert des Redoxpotentials gegenüber der Ag/AgCl-Elektrode (3 mol KCI); Am festen Standort (S) Redoxpotential Wert des Redoxpotentials gegenüber der Ag/AgCl-Elektrode (3 mol KCI) Am festen Standort (S) ASTM D1498-14","technique_de":"Wert des Redoxpotentials gegenüber der Ag/AgCl-Elektrode (3 mol KCI); Am festen Standort (S)","techniques_de":["Wert des Redoxpotentials gegenüber der Ag/AgCl-Elektrode (3 mol KCI)","Am festen Standort (S)"],"test_object_de":"Redoxelektroden","methodology_zh":"校准 — 氧化还原电位","parameters_zh":[{"name":"","range":"200 mV to 700 mV","cmc":"5 mV"}],"regulatory_area_zh":"氧化还原电位","search_zh":"氧化还原电极 校准 — 氧化还原电位 相对于Ag/AgCl电极（3 mol KCI）的氧化还原电位值；在固定地点 (S) 氧化还原电位 相对于Ag/AgCl电极（3 mol KCI）的氧化还原电位值 在固定地点 (S) ASTM D1498-14","technique_zh":"相对于Ag/AgCl电极（3 mol KCI）的氧化还原电位值；在固定地点 (S)","techniques_zh":["相对于Ag/AgCl电极（3 mol KCI）的氧化还原电位值","在固定地点 (S)"],"test_object_zh":"氧化还原电极","methodology_cs":"Kalibrace — Redoxní potenciál","parameters_cs":[{"name":"","range":"200 mV to 700 mV","cmc":"5 mV"}],"regulatory_area_cs":"Redoxní potenciál","search_cs":"Redoxní elektrody Kalibrace — Redoxní potenciál Hodnota redoxního potenciálu vůči elektrodě Ag/AgCl (3 mol KCI); Ve stálé lokalitě (S) Redoxní potenciál Hodnota redoxního potenciálu vůči elektrodě Ag/AgCl (3 mol KCI) Ve stálé lokalitě (S) ASTM D1498-14","technique_cs":"Hodnota redoxního potenciálu vůči elektrodě Ag/AgCl (3 mol KCI); Ve stálé lokalitě (S)","techniques_cs":["Hodnota redoxního potenciálu vůči elektrodě Ag/AgCl (3 mol KCI)","Ve stálé lokalitě (S)"],"test_object_cs":"Redoxní elektrody"},{"_id":"1cf514d8b3ffc979402776a5","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Wzorce pehametryczne","test_object_en":"pH reference materials","methodology":"Wzorcowanie — Materiały odniesienia – pomiar","methodology_en":"Calibration — Reference materials - measurement","parameters":[{"name":"","range":"1,00 do 8,00","cmc":"0,01"},{"name":"","range":"8,00 do 10,10","cmc":"0,02"},{"name":"","range":"10,1 do 12,5","cmc":"0,1"}],"parameters_en":[{"name":"","range":"1,00 to 8,00","cmc":"0,01"},{"name":"","range":"8,00 to 10,10","cmc":"0,02"},{"name":"","range":"10,1 to 12,5","cmc":"0,1"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Materiały odniesienia – pomiar\nZakres:\n1,00 do 8,00 CMC 0,01\n8,00 do 10,10 CMC 0,02\n10,1 do 12,5 CMC 0,1\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PP 01/200","norm_bases":["PP 01/200"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Materiały odniesienia – pomiar","regulatory_area_en":"Reference materials - measurement","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce pehametryczne Wzorcowanie — Materiały odniesienia – pomiar\nZakres:\n1,00 do 8,00 CMC 0,01\n8,00 do 10,10 CMC 0,02\n10,1 do 12,5 CMC 0,1\nProcedura wewnętrzna; W stałej lokalizacji (S) PP 01/200 Wzorce pehametryczne Wzorcowanie — Materialy odniesienia – pomiar\nZakres:\n1,00 do 8,00 CMC 0,01\n8,00 do 10,10 CMC 0,02\n10,1 do 12,5 CMC 0,1\nProcedura wewnetrzna; W stalej lokalizacji (S) PP 01/200","search_en":"pH reference materials Calibration — Reference materials - measurement Internal procedure; At permanent location (S) Reference materials - measurement Internal procedure At permanent location (S) PP 01/200","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Referenzmaterialien – Messung","parameters_de":[{"name":"","range":"1,00 to 8,00","cmc":"0,01"},{"name":"","range":"8,00 to 10,10","cmc":"0,02"},{"name":"","range":"10,1 to 12,5","cmc":"0,1"}],"regulatory_area_de":"Referenzmaterialien – Messung","search_de":"pH-Referenzmaterialien Kalibrierung — Referenzmaterialien – Messung Internes Verfahren; Am festen Standort (S) Referenzmaterialien – Messung Internes Verfahren Am festen Standort (S) PP 01/200","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"pH-Referenzmaterialien","methodology_zh":"校准 — 标准物质 – 测量","parameters_zh":[{"name":"","range":"1,00 to 8,00","cmc":"0,01"},{"name":"","range":"8,00 to 10,10","cmc":"0,02"},{"name":"","range":"10,1 to 12,5","cmc":"0,1"}],"regulatory_area_zh":"标准物质 – 测量","search_zh":"pH参考物质 校准 — 标准物质 – 测量 内部程序；在固定地点 (S) 标准物质 – 测量 内部程序 在固定地点 (S) PP 01/200","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"pH参考物质","methodology_cs":"Kalibrace — Referenční materiály – měření","parameters_cs":[{"name":"","range":"1,00 to 8,00","cmc":"0,01"},{"name":"","range":"8,00 to 10,10","cmc":"0,02"},{"name":"","range":"10,1 to 12,5","cmc":"0,1"}],"regulatory_area_cs":"Referenční materiály – měření","search_cs":"pH etalony Kalibrace — Referenční materiály – měření Vnitřní postup; Ve stálé lokalitě (S) Referenční materiály – měření Vnitřní postup Ve stálé lokalitě (S) PP 01/200","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"pH etalony"},{"_id":"693e825636c9c58e359a159a","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Wzorce wiskozymetryczne (lepkości)","test_object_en":"Viscosity reference materials","methodology":"Wzorcowanie — Materiały odniesienia – pomiar","methodology_en":"Calibration — Reference materials - measurement","parameters":[{"name":"","range":"1 mm²/s do 140 mm²/s","cmc":"0,2 %"},{"name":"","range":"1 mPa · s do 140 mPa · s","cmc":"0,2 %"},{"name":"","range":"140 mm²/s do 2000 mm²/s","cmc":"0,3 %"},{"name":"","range":"140 mPa · s do 2000 mPa · s","cmc":"0,3 %"}],"parameters_en":[{"name":"","range":"1 mm²/s to 140 mm²/s","cmc":"0,2 %"},{"name":"","range":"1 mPa · s to 140 mPa · s","cmc":"0,2 %"},{"name":"","range":"140 mm²/s to 2000 mm²/s","cmc":"0,3 %"},{"name":"","range":"140 mPa · s to 2000 mPa · s","cmc":"0,3 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Materiały odniesienia – pomiar\nZakres:\n1 mm²/s do 140 mm²/s CMC 0,2 %\n1 mPa · s do 140 mPa · s CMC 0,2 %\n140 mm²/s do 2000 mm²/s CMC 0,3 %\n140 mPa · s do 2000 mPa · s CMC 0,3 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PP 02/200 PP 02/201","norm_bases":["PP 02/200","PP 02/201"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Materiały odniesienia – pomiar","regulatory_area_en":"Reference materials - measurement","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce wiskozymetryczne (lepkości) Wzorcowanie — Materiały odniesienia – pomiar\nZakres:\n1 mm²/s do 140 mm²/s CMC 0,2 %\n1 mPa · s do 140 mPa · s CMC 0,2 %\n140 mm²/s do 2000 mm²/s CMC 0,3 %\n140 mPa · s do 2000 mPa · s CMC 0,3 %\nProcedura wewnętrzna; W stałej lokalizacji (S) PP 02/200 PP 02/201 Wzorce wiskozymetryczne (lepkosci) Wzorcowanie — Materialy odniesienia – pomiar\nZakres:\n1 mm²/s do 140 mm²/s CMC 0,2 %\n1 mPa · s do 140 mPa · s CMC 0,2 %\n140 mm²/s do 2000 mm²/s CMC 0,3 %\n140 mPa · s do 2000 mPa · s CMC 0,3 %\nProcedura wewnetrzna; W stalej lokalizacji (S) PP 02/200 PP 02/201","search_en":"Viscosity reference materials Calibration — Reference materials - measurement Internal procedure; At permanent location (S) Reference materials - measurement Internal procedure At permanent location (S) PP 02/200 PP 02/201","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Referenzmaterialien – Messung","parameters_de":[{"name":"","range":"1 mm²/s to 140 mm²/s","cmc":"0,2 %"},{"name":"","range":"1 mPa · s to 140 mPa · s","cmc":"0,2 %"},{"name":"","range":"140 mm²/s to 2000 mm²/s","cmc":"0,3 %"},{"name":"","range":"140 mPa · s to 2000 mPa · s","cmc":"0,3 %"}],"regulatory_area_de":"Referenzmaterialien – Messung","search_de":"Viskositätsreferenzmaterialien Kalibrierung — Referenzmaterialien – Messung Internes Verfahren; Am festen Standort (S) Referenzmaterialien – Messung Internes Verfahren Am festen Standort (S) PP 02/200 PP 02/201","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Viskositätsreferenzmaterialien","methodology_zh":"校准 — 标准物质 – 测量","parameters_zh":[{"name":"","range":"1 mm²/s to 140 mm²/s","cmc":"0,2 %"},{"name":"","range":"1 mPa · s to 140 mPa · s","cmc":"0,2 %"},{"name":"","range":"140 mm²/s to 2000 mm²/s","cmc":"0,3 %"},{"name":"","range":"140 mPa · s to 2000 mPa · s","cmc":"0,3 %"}],"regulatory_area_zh":"标准物质 – 测量","search_zh":"黏度参考物质 校准 — 标准物质 – 测量 内部程序；在固定地点 (S) 标准物质 – 测量 内部程序 在固定地点 (S) PP 02/200 PP 02/201","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"黏度参考物质","methodology_cs":"Kalibrace — Referenční materiály – měření","parameters_cs":[{"name":"","range":"1 mm²/s to 140 mm²/s","cmc":"0,2 %"},{"name":"","range":"1 mPa · s to 140 mPa · s","cmc":"0,2 %"},{"name":"","range":"140 mm²/s to 2000 mm²/s","cmc":"0,3 %"},{"name":"","range":"140 mPa · s to 2000 mPa · s","cmc":"0,3 %"}],"regulatory_area_cs":"Referenční materiály – měření","search_cs":"Viskozimetrické etalony (viskozity) Kalibrace — Referenční materiály – měření Vnitřní postup; Ve stálé lokalitě (S) Referenční materiály – měření Vnitřní postup Ve stálé lokalitě (S) PP 02/200 PP 02/201","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Viskozimetrické etalony (viskozity)"},{"_id":"5786717298c94a15cc119c54","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Wzorce konduktometryczne","test_object_en":"Conductivity reference materials","methodology":"Wzorcowanie — Materiały odniesienia – pomiar","methodology_en":"Calibration — Reference materials - measurement","parameters":[{"name":"","range":"0,0004 S/m do 12,0 S/m","cmc":"0,4 %"}],"parameters_en":[{"name":"","range":"0,0004 S/m to 12,0 S/m","cmc":"0,4 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Materiały odniesienia – pomiar\n0,0004 S/m do 12,0 S/m CMC 0,4 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PP 07/200","norm_bases":["PP 07/200"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Materiały odniesienia – pomiar","regulatory_area_en":"Reference materials - measurement","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce konduktometryczne Wzorcowanie — Materiały odniesienia – pomiar\n0,0004 S/m do 12,0 S/m CMC 0,4 %\nProcedura wewnętrzna; W stałej lokalizacji (S) PP 07/200 Wzorce konduktometryczne Wzorcowanie — Materialy odniesienia – pomiar\n0,0004 S/m do 12,0 S/m CMC 0,4 %\nProcedura wewnetrzna; W stalej lokalizacji (S) PP 07/200","search_en":"Conductivity reference materials Calibration — Reference materials - measurement Internal procedure; At permanent location (S) Reference materials - measurement Internal procedure At permanent location (S) PP 07/200","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Referenzmaterialien – Messung","parameters_de":[{"name":"","range":"0,0004 S/m to 12,0 S/m","cmc":"0,4 %"}],"regulatory_area_de":"Referenzmaterialien – Messung","search_de":"Leitfähigkeitsreferenzmaterialien Kalibrierung — Referenzmaterialien – Messung Internes Verfahren; Am festen Standort (S) Referenzmaterialien – Messung Internes Verfahren Am festen Standort (S) PP 07/200","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Leitfähigkeitsreferenzmaterialien","methodology_zh":"校准 — 标准物质 – 测量","parameters_zh":[{"name":"","range":"0,0004 S/m to 12,0 S/m","cmc":"0,4 %"}],"regulatory_area_zh":"标准物质 – 测量","search_zh":"电导率参考物质 校准 — 标准物质 – 测量 内部程序；在固定地点 (S) 标准物质 – 测量 内部程序 在固定地点 (S) PP 07/200","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电导率参考物质","methodology_cs":"Kalibrace — Referenční materiály – měření","parameters_cs":[{"name":"","range":"0,0004 S/m to 12,0 S/m","cmc":"0,4 %"}],"regulatory_area_cs":"Referenční materiály – měření","search_cs":"Konduktometrické etalony Kalibrace — Referenční materiály – měření Vnitřní postup; Ve stálé lokalitě (S) Referenční materiály – měření Vnitřní postup Ve stálé lokalitě (S) PP 07/200","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Konduktometrické etalony"},{"_id":"82b04108de7fe2ee386e4b4c","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Wzorce redoks","test_object_en":"Redox reference material","methodology":"Wzorcowanie — Materiały odniesienia – pomiar","methodology_en":"Calibration — Reference materials - measurement","parameters":[{"name":"","range":"200 mV do 700 mV","cmc":"5 mV"}],"parameters_en":[{"name":"","range":"200 mV to 700 mV","cmc":"5 mV"}],"technique":"Wartość potencjału redoks względem elektrody Ag/AgCl (3 mol KCI); W stałej lokalizacji (S)","technique_en":"Value of the redox potential relative to the Ag/AgCl electrode (3 mol KCI); At permanent location (S)","techniques":["Wartość potencjału redoks względem elektrody Ag/AgCl (3 mol KCI)","W stałej lokalizacji (S)"],"techniques_en":["Value of the redox potential relative to the Ag/AgCl electrode (3 mol KCI)","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Materiały odniesienia – pomiar\n200 mV do 700 mV CMC 5 mV\nWartość potencjału redoks względem elektrody Ag/AgCl (3 mol KCI); W stałej lokalizacji (S)","reference":"ASTM D1498-14","norm_bases":["ASTM D1498-14"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Materiały odniesienia – pomiar","regulatory_area_en":"Reference materials - measurement","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce redoks Wzorcowanie — Materiały odniesienia – pomiar\n200 mV do 700 mV CMC 5 mV\nWartość potencjału redoks względem elektrody Ag/AgCl (3 mol KCI); W stałej lokalizacji (S) ASTM D1498-14 Wzorce redoks Wzorcowanie — Materialy odniesienia – pomiar\n200 mV do 700 mV CMC 5 mV\nWartosc potencjalu redoks wzgledem elektrody Ag/AgCl (3 mol KCI); W stalej lokalizacji (S) ASTM D1498-14","search_en":"Redox reference material Calibration — Reference materials - measurement Value of the redox potential relative to the Ag/AgCl electrode (3 mol KCI); At permanent location (S) Reference materials - measurement Value of the redox potential relative to the Ag/AgCl electrode (3 mol KCI) At permanent location (S) ASTM D1498-14","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Referenzmaterialien – Messung","parameters_de":[{"name":"","range":"200 mV to 700 mV","cmc":"5 mV"}],"regulatory_area_de":"Referenzmaterialien – Messung","search_de":"Redox-Referenzmaterial Kalibrierung — Referenzmaterialien – Messung Wert des Redoxpotentials gegenüber der Ag/AgCl-Elektrode (3 mol KCI); Am festen Standort (S) Referenzmaterialien – Messung Wert des Redoxpotentials gegenüber der Ag/AgCl-Elektrode (3 mol KCI) Am festen Standort (S) ASTM D1498-14","technique_de":"Wert des Redoxpotentials gegenüber der Ag/AgCl-Elektrode (3 mol KCI); Am festen Standort (S)","techniques_de":["Wert des Redoxpotentials gegenüber der Ag/AgCl-Elektrode (3 mol KCI)","Am festen Standort (S)"],"test_object_de":"Redox-Referenzmaterial","methodology_zh":"校准 — 标准物质 – 测量","parameters_zh":[{"name":"","range":"200 mV to 700 mV","cmc":"5 mV"}],"regulatory_area_zh":"标准物质 – 测量","search_zh":"氧化还原参考物质 校准 — 标准物质 – 测量 相对于Ag/AgCl电极（3 mol KCI）的氧化还原电位值；在固定地点 (S) 标准物质 – 测量 相对于Ag/AgCl电极（3 mol KCI）的氧化还原电位值 在固定地点 (S) ASTM D1498-14","technique_zh":"相对于Ag/AgCl电极（3 mol KCI）的氧化还原电位值；在固定地点 (S)","techniques_zh":["相对于Ag/AgCl电极（3 mol KCI）的氧化还原电位值","在固定地点 (S)"],"test_object_zh":"氧化还原参考物质","methodology_cs":"Kalibrace — Referenční materiály – měření","parameters_cs":[{"name":"","range":"200 mV to 700 mV","cmc":"5 mV"}],"regulatory_area_cs":"Referenční materiály – měření","search_cs":"Redoxní etalony Kalibrace — Referenční materiály – měření Hodnota redoxního potenciálu vůči elektrodě Ag/AgCl (3 mol KCI); Ve stálé lokalitě (S) Referenční materiály – měření Hodnota redoxního potenciálu vůči elektrodě Ag/AgCl (3 mol KCI) Ve stálé lokalitě (S) ASTM D1498-14","technique_cs":"Hodnota redoxního potenciálu vůči elektrodě Ag/AgCl (3 mol KCI); Ve stálé lokalitě (S)","techniques_cs":["Hodnota redoxního potenciálu vůči elektrodě Ag/AgCl (3 mol KCI)","Ve stálé lokalitě (S)"],"test_object_cs":"Redoxní etalony"},{"_id":"d93bd78a8e8cfba019386234","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Piknometry","test_object_en":"Pycnometers","methodology":"Wzorcowanie — Gęstość (ciecz)","methodology_en":"Calibration — Density (liquid)","parameters":[{"name":"- objętość","range":"10 cm³ do 51 cm³","cmc":"0,003 cm³"},{"name":"- objętość","range":"51 cm³ do 201 cm³","cmc":"0,01 cm³"},{"name":"- objętość","range":"202 cm³ do 2000 cm³","cmc":"0,3 cm³"}],"parameters_en":[{"name":"volume","range":"10 cm³ to 51 cm³","cmc":"0,003 cm³"},{"name":"volume","range":"51 cm³ to 201 cm³","cmc":"0,01 cm³"},{"name":"volume","range":"202 cm³ to 2000 cm³","cmc":"0,3 cm³"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Gęstość (ciecz)\nZakres:\n- objętość 10 cm³ do 51 cm³ CMC 0,003 cm³\n- objętość 51 cm³ do 201 cm³ CMC 0,01 cm³\n- objętość 202 cm³ do 2000 cm³ CMC 0,3 cm³\nW stałej lokalizacji (S)","reference":"PN-EN ISO 2811-1:2023-03","norm_bases":["PN-EN ISO 2811-1:2023-03"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Gęstość (ciecz)","regulatory_area_en":"Density (liquid)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Piknometry Wzorcowanie — Gęstość (ciecz)\nZakres:\n- objętość 10 cm³ do 51 cm³ CMC 0,003 cm³\n- objętość 51 cm³ do 201 cm³ CMC 0,01 cm³\n- objętość 202 cm³ do 2000 cm³ CMC 0,3 cm³\nW stałej lokalizacji (S) PN-EN ISO 2811-1:2023-03 Piknometry Wzorcowanie — Gestosc (ciecz)\nZakres:\n- objetosc 10 cm³ do 51 cm³ CMC 0,003 cm³\n- objetosc 51 cm³ do 201 cm³ CMC 0,01 cm³\n- objetosc 202 cm³ do 2000 cm³ CMC 0,3 cm³\nW stalej lokalizacji (S) PN-EN ISO 2811-1:2023-03","search_en":"Pycnometers Calibration — Density (liquid) At permanent location (S) Density (liquid) At permanent location (S) volume volume volume PN-EN ISO 2811-1:2023-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Dichte (Flüssigkeit)","parameters_de":[{"name":"- Volumen","range":"10 cm³ to 51 cm³","cmc":"0,003 cm³"},{"name":"- Volumen","range":"51 cm³ to 201 cm³","cmc":"0,01 cm³"},{"name":"- Volumen","range":"202 cm³ to 2000 cm³","cmc":"0,3 cm³"}],"regulatory_area_de":"Dichte (Flüssigkeit)","search_de":"Pyknometer Kalibrierung — Dichte (Flüssigkeit) Am festen Standort (S) Dichte (Flüssigkeit) Am festen Standort (S) - Volumen - Volumen - Volumen PN-EN ISO 2811-1:2023-03","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Pyknometer","methodology_zh":"校准 — 密度（液体）","parameters_zh":[{"name":"- 体积","range":"10 cm³ to 51 cm³","cmc":"0,003 cm³"},{"name":"- 体积","range":"51 cm³ to 201 cm³","cmc":"0,01 cm³"},{"name":"- 体积","range":"202 cm³ to 2000 cm³","cmc":"0,3 cm³"}],"regulatory_area_zh":"密度（液体）","search_zh":"比重瓶 校准 — 密度（液体） 在固定地点 (S) 密度（液体） 在固定地点 (S) - 体积 - 体积 - 体积 PN-EN ISO 2811-1:2023-03","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"比重瓶","methodology_cs":"Kalibrace — Hustota (kapalina)","parameters_cs":[{"name":"- objem","range":"10 cm³ to 51 cm³","cmc":"0,003 cm³"},{"name":"- objem","range":"51 cm³ to 201 cm³","cmc":"0,01 cm³"},{"name":"- objem","range":"202 cm³ to 2000 cm³","cmc":"0,3 cm³"}],"regulatory_area_cs":"Hustota (kapalina)","search_cs":"Pyknometry Kalibrace — Hustota (kapalina) Ve stálé lokalitě (S) Hustota (kapalina) Ve stálé lokalitě (S) - objem - objem - objem PN-EN ISO 2811-1:2023-03","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Pyknometry"},{"_id":"198a58aa3fe27698fc499333","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Wiskozymetry szklane kapilarne","test_object_en":"Glass capillary viscometers","methodology":"Wzorcowanie — Lepkość","methodology_en":"Calibration — Viscosity","parameters":[{"name":"","range":"0,001 mm²/s² do 10,5 mm²/s²","cmc":"0,5 %"}],"parameters_en":[{"name":"","range":"0,001 mm²/s² to 10,5 mm²/s²","cmc":"0,5 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Lepkość\n0,001 mm²/s² do 10,5 mm²/s² CMC 0,5 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PT 02/300","norm_bases":["PT 02/300"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Lepkość","regulatory_area_en":"Viscosity","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wiskozymetry szklane kapilarne Wzorcowanie — Lepkość\n0,001 mm²/s² do 10,5 mm²/s² CMC 0,5 %\nProcedura wewnętrzna; W stałej lokalizacji (S) PT 02/300 Wiskozymetry szklane kapilarne Wzorcowanie — Lepkosc\n0,001 mm²/s² do 10,5 mm²/s² CMC 0,5 %\nProcedura wewnetrzna; W stalej lokalizacji (S) PT 02/300","search_en":"Glass capillary viscometers Calibration — Viscosity Internal procedure; At permanent location (S) Viscosity Internal procedure At permanent location (S) PT 02/300","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Viskosität","parameters_de":[{"name":"","range":"0,001 mm²/s² to 10,5 mm²/s²","cmc":"0,5 %"}],"regulatory_area_de":"Viskosität","search_de":"Glaskapillarviskosimeter Kalibrierung — Viskosität Internes Verfahren; Am festen Standort (S) Viskosität Internes Verfahren Am festen Standort (S) PT 02/300","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Glaskapillarviskosimeter","methodology_zh":"校准 — 黏度","parameters_zh":[{"name":"","range":"0,001 mm²/s² to 10,5 mm²/s²","cmc":"0,5 %"}],"regulatory_area_zh":"黏度","search_zh":"玻璃毛细管黏度计 校准 — 黏度 内部程序；在固定地点 (S) 黏度 内部程序 在固定地点 (S) PT 02/300","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"玻璃毛细管黏度计","methodology_cs":"Kalibrace — Viskozita","parameters_cs":[{"name":"","range":"0,001 mm²/s² to 10,5 mm²/s²","cmc":"0,5 %"}],"regulatory_area_cs":"Viskozita","search_cs":"Skleněné kapilární viskozimetry Kalibrace — Viskozita Vnitřní postup; Ve stálé lokalitě (S) Viskozita Vnitřní postup Ve stálé lokalitě (S) PT 02/300","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Skleněné kapilární viskozimetry"},{"_id":"86377b6aaf6b4ef3e100ea50","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Wiskozymetry rotacyjne","test_object_en":"Rotational viscometers","methodology":"Wzorcowanie — Lepkość","methodology_en":"Calibration — Viscosity","parameters":[{"name":"","range":"1 mPa · s do 2000 mPa · s","cmc":"2 %"},{"name":"","range":"2000 mPa · s do 15000 mPa · s","cmc":"3 %"}],"parameters_en":[{"name":"","range":"1 mPa · s to 2000 mPa · s","cmc":"2 %"},{"name":"","range":"2000 mPa · s to 15000 mPa · s","cmc":"3 %"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Lepkość\nZakres:\n1 mPa · s do 2000 mPa · s CMC 2 %\n2000 mPa · s do 15000 mPa · s CMC 3 %\nW stałej lokalizacji (S) i poza nią (P)","reference":"PN-EN ISO 2555:2018-07 DIN 53019-2:2001","norm_bases":["PN-EN ISO 2555:2018-07","DIN 53019-2:2001"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Lepkość","regulatory_area_en":"Viscosity","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Wiskozymetry rotacyjne Wzorcowanie — Lepkość\nZakres:\n1 mPa · s do 2000 mPa · s CMC 2 %\n2000 mPa · s do 15000 mPa · s CMC 3 %\nW stałej lokalizacji (S) i poza nią (P) PN-EN ISO 2555:2018-07 DIN 53019-2:2001 Wiskozymetry rotacyjne Wzorcowanie — Lepkosc\nZakres:\n1 mPa · s do 2000 mPa · s CMC 2 %\n2000 mPa · s do 15000 mPa · s CMC 3 %\nW stalej lokalizacji (S) i poza nia (P) PN-EN ISO 2555:2018-07 DIN 53019-2:2001","search_en":"Rotational viscometers Calibration — Viscosity At permanent location (S) and outside of it (P) Viscosity At permanent location (S) and outside of it (P) PN-EN ISO 2555:2018-07 DIN 53019-2:2001","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Viskosität","parameters_de":[{"name":"","range":"1 mPa · s to 2000 mPa · s","cmc":"2 %"},{"name":"","range":"2000 mPa · s to 15000 mPa · s","cmc":"3 %"}],"regulatory_area_de":"Viskosität","search_de":"Rotationsviskosimeter Kalibrierung — Viskosität Am festen Standort (S) und außerhalb (P) Viskosität Am festen Standort (S) und außerhalb (P) PN-EN ISO 2555:2018-07 DIN 53019-2:2001","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Rotationsviskosimeter","methodology_zh":"校准 — 黏度","parameters_zh":[{"name":"","range":"1 mPa · s to 2000 mPa · s","cmc":"2 %"},{"name":"","range":"2000 mPa · s to 15000 mPa · s","cmc":"3 %"}],"regulatory_area_zh":"黏度","search_zh":"旋转黏度计 校准 — 黏度 在固定地点 (S) 及固定地点以外 (P) 黏度 在固定地点 (S) 及固定地点以外 (P) PN-EN ISO 2555:2018-07 DIN 53019-2:2001","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"旋转黏度计","methodology_cs":"Kalibrace — Viskozita","parameters_cs":[{"name":"","range":"1 mPa · s to 2000 mPa · s","cmc":"2 %"},{"name":"","range":"2000 mPa · s to 15000 mPa · s","cmc":"3 %"}],"regulatory_area_cs":"Viskozita","search_cs":"Rotační viskozimetry Kalibrace — Viskozita V trvalé lokalitě (S) i mimo ni (P) Viskozita V trvalé lokalitě (S) i mimo ni (P) PN-EN ISO 2555:2018-07 DIN 53019-2:2001","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Rotační viskozimetry"},{"_id":"b8bac1e05044a4a203c6d09e","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Higrometry\nTermohigrometry","test_object_en":"Hygrometers\nThermohygrometers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"temperatura","range":"15 °C do 20 °C","cmc":"0,1 °C"},{"name":"wilgotność względna","range":"20 %rh do 30 %rh","cmc":"0,7 %rh"},{"name":"temperatura","range":"20 °C do 40 °C","cmc":"0,1 °C"},{"name":"wilgotność względna","range":"20 %rh do 30 %rh","cmc":"0,7 %rh"},{"name":"temperatura","range":"10 °C do 42 °C","cmc":"0,1 °C"},{"name":"wilgotność względna","range":"30 %rh do 85 %rh","cmc":"0,7 %rh"},{"name":"temperatura","range":"7 °C do 10 °C","cmc":"0,1 °C"},{"name":"wilgotność względna","range":"30 %rh do 50 %rh","cmc":"0,8 %rh"},{"name":"temperatura","range":"5 °C do 10 °C","cmc":"0,1 °C"},{"name":"wilgotność względna","range":"50 %rh do 85 %rh","cmc":"0,8 %rh"},{"name":"temperatura","range":"42 °C do 50 °C","cmc":"0,1 °C"},{"name":"wilgotność względna","range":"20 %rh do 60 %rh","cmc":"0,8 %rh"}],"parameters_en":[{"name":"temperature","range":"15 °C to 20 °C","cmc":"0,1 °C"},{"name":"relative humidity","range":"20 %rh to 30 %rh","cmc":"0,7 %rh"},{"name":"temperature","range":"20 °C to 40 °C","cmc":"0,1 °C"},{"name":"relative humidity","range":"20 %rh to 30 %rh","cmc":"0,7 %rh"},{"name":"temperature","range":"10 °C to 42 °C","cmc":"0,1 °C"},{"name":"relative humidity","range":"30 %rh to 85 %rh","cmc":"0,7 %rh"},{"name":"temperature","range":"7 °C to 10 °C","cmc":"0,1 °C"},{"name":"relative humidity","range":"30 %rh to 50 %rh","cmc":"0,8 %rh"},{"name":"temperature","range":"5 °C to 10 °C","cmc":"0,1 °C"},{"name":"relative humidity","range":"50 %rh to 85 %rh","cmc":"0,8 %rh"},{"name":"temperature","range":"42 °C to 50 °C","cmc":"0,1 °C"},{"name":"relative humidity","range":"20 %rh to 60 %rh","cmc":"0,8 %rh"}],"technique":"Procedura wewnętrzna; Metoda pośrednia\nMetoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method\nDirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia\nMetoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method\nDirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nZakres:\ntemperatura 15 °C do 20 °C CMC 0,1 °C\nwilgotność względna 20 %rh do 30 %rh CMC 0,7 %rh\ntemperatura 20 °C do 40 °C CMC 0,1 °C\nwilgotność względna 20 %rh do 30 %rh CMC 0,7 %rh\ntemperatura 10 °C do 42 °C CMC 0,1 °C\nwilgotność względna 30 %rh do 85 %rh CMC 0,7 %rh\ntemperatura 7 °C do 10 °C CMC 0,1 °C\nwilgotność względna 30 %rh do 50 %rh CMC 0,8 %rh\ntemperatura 5 °C do 10 °C CMC 0,1 °C\nwilgotność względna 50 %rh do 85 %rh CMC 0,8 %rh\ntemperatura 42 °C do 50 °C CMC 0,1 °C\nwilgotność względna 20 %rh do 60 %rh CMC 0,8 %rh\nProcedura wewnętrzna; Metoda pośrednia\nMetoda bezpośrednia; W stałej lokalizacji (S)","reference":"PT 09/100","norm_bases":["PT 09/100"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Higrometry\nTermohigrometry Wzorcowanie — Wilgotność względna\nZakres:\ntemperatura 15 °C do 20 °C CMC 0,1 °C\nwilgotność względna 20 %rh do 30 %rh CMC 0,7 %rh\ntemperatura 20 °C do 40 °C CMC 0,1 °C\nwilgotność względna 20 %rh do 30 %rh CMC 0,7 %rh\ntemperatura 10 °C do 42 °C CMC 0,1 °C\nwilgotność względna 30 %rh do 85 %rh CMC 0,7 %rh\ntemperatura 7 °C do 10 °C CMC 0,1 °C\nwilgotność względna 30 %rh do 50 %rh CMC 0,8 %rh\ntemperatura 5 °C do 10 °C CMC 0,1 °C\nwilgotność względna 50 %rh do 85 %rh CMC 0,8 %rh\ntemperatura 42 °C do 50 °C CMC 0,1 °C\nwilgotność względna 20 %rh do 60 %rh CMC 0,8 %rh\nProcedura wewnętrzna; Metoda pośrednia\nMetoda bezpośrednia; W stałej lokalizacji (S) PT 09/100 Higrometry\nTermohigrometry Wzorcowanie — Wilgotnosc wzgledna\nZakres:\ntemperatura 15 °C do 20 °C CMC 0,1 °C\nwilgotnosc wzgledna 20 %rh do 30 %rh CMC 0,7 %rh\ntemperatura 20 °C do 40 °C CMC 0,1 °C\nwilgotnosc wzgledna 20 %rh do 30 %rh CMC 0,7 %rh\ntemperatura 10 °C do 42 °C CMC 0,1 °C\nwilgotnosc wzgledna 30 %rh do 85 %rh CMC 0,7 %rh\ntemperatura 7 °C do 10 °C CMC 0,1 °C\nwilgotnosc wzgledna 30 %rh do 50 %rh CMC 0,8 %rh\ntemperatura 5 °C do 10 °C CMC 0,1 °C\nwilgotnosc wzgledna 50 %rh do 85 %rh CMC 0,8 %rh\ntemperatura 42 °C do 50 °C CMC 0,1 °C\nwilgotnosc wzgledna 20 %rh do 60 %rh CMC 0,8 %rh\nProcedura wewnetrzna; Metoda posrednia\nMetoda bezposrednia; W stalej lokalizacji (S) PT 09/100","search_en":"Hygrometers Thermohygrometers Calibration — Relative humidity Internal procedure; Indirect method Direct method; At permanent location (S) Relative humidity Internal procedure Indirect method Direct method At permanent location (S) temperature relative humidity temperature relative humidity temperature relative humidity temperature relative humidity temperature relative humidity temperature relative humidity PT 09/100","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"Temperatur","range":"15 °C to 20 °C","cmc":"0,1 °C"},{"name":"relative Feuchte","range":"20 %rh to 30 %rh","cmc":"0,7 %rh"},{"name":"Temperatur","range":"20 °C bis 40 °C","cmc":"0,1 °C"},{"name":"relative Feuchte","range":"20 %rh to 30 %rh","cmc":"0,7 %rh"},{"name":"Temperatur","range":"10 °C to 42 °C","cmc":"0,1 °C"},{"name":"relative Feuchte","range":"30 %rh to 85 %rh","cmc":"0,7 %rh"},{"name":"Temperatur","range":"7 °C to 10 °C","cmc":"0,1 °C"},{"name":"relative Feuchte","range":"30 %rh to 50 %rh","cmc":"0,8 %rh"},{"name":"Temperatur","range":"5 °C to 10 °C","cmc":"0,1 °C"},{"name":"relative Feuchte","range":"50 %rh to 85 %rh","cmc":"0,8 %rh"},{"name":"Temperatur","range":"42 °C to 50 °C","cmc":"0,1 °C"},{"name":"relative Feuchte","range":"20 %rh to 60 %rh","cmc":"0,8 %rh"}],"regulatory_area_de":"Relative Feuchte","search_de":"Hygrometer Thermohygrometer Kalibrierung — Relative Feuchte Internes Verfahren; Indirektes Verfahren Direktes Verfahren; Am festen Standort (S) Relative Feuchte Internes Verfahren Indirektes Verfahren Direktes Verfahren Am festen Standort (S) Temperatur relative Feuchte Temperatur relative Feuchte Temperatur relative Feuchte Temperatur relative Feuchte Temperatur relative Feuchte Temperatur relative Feuchte PT 09/100","technique_de":"Internes Verfahren; Indirektes Verfahren\nDirektes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren\nDirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Hygrometer\nThermohygrometer","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度","range":"15 °C to 20 °C","cmc":"0,1 °C"},{"name":"相对湿度","range":"20 %rh to 30 %rh","cmc":"0,7 %rh"},{"name":"温度","range":"20 °C 至 40 °C","cmc":"0,1 °C"},{"name":"相对湿度","range":"20 %rh to 30 %rh","cmc":"0,7 %rh"},{"name":"温度","range":"10 °C to 42 °C","cmc":"0,1 °C"},{"name":"相对湿度","range":"30 %rh to 85 %rh","cmc":"0,7 %rh"},{"name":"温度","range":"7 °C to 10 °C","cmc":"0,1 °C"},{"name":"相对湿度","range":"30 %rh to 50 %rh","cmc":"0,8 %rh"},{"name":"温度","range":"5 °C to 10 °C","cmc":"0,1 °C"},{"name":"相对湿度","range":"50 %rh to 85 %rh","cmc":"0,8 %rh"},{"name":"温度","range":"42 °C to 50 °C","cmc":"0,1 °C"},{"name":"相对湿度","range":"20 %rh to 60 %rh","cmc":"0,8 %rh"}],"regulatory_area_zh":"相对湿度","search_zh":"湿度计 温湿度计 校准 — 相对湿度 内部程序；间接法 直接法；在固定地点 (S) 相对湿度 内部程序 间接法 直接法 在固定地点 (S) 温度 相对湿度 温度 相对湿度 温度 相对湿度 温度 相对湿度 温度 相对湿度 温度 相对湿度 PT 09/100","technique_zh":"内部程序；间接法\n直接法；在固定地点 (S)","techniques_zh":["内部程序","间接法\n直接法","在固定地点 (S)"],"test_object_zh":"湿度计\n温湿度计","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"teplota","range":"15 °C to 20 °C","cmc":"0,1 °C"},{"name":"relativní vlhkost","range":"20 %rh to 30 %rh","cmc":"0,7 %rh"},{"name":"teplota","range":"20 °C až 40 °C","cmc":"0,1 °C"},{"name":"relativní vlhkost","range":"20 %rh to 30 %rh","cmc":"0,7 %rh"},{"name":"teplota","range":"10 °C to 42 °C","cmc":"0,1 °C"},{"name":"relativní vlhkost","range":"30 %rh to 85 %rh","cmc":"0,7 %rh"},{"name":"teplota","range":"7 °C to 10 °C","cmc":"0,1 °C"},{"name":"relativní vlhkost","range":"30 %rh to 50 %rh","cmc":"0,8 %rh"},{"name":"teplota","range":"5 °C to 10 °C","cmc":"0,1 °C"},{"name":"relativní vlhkost","range":"50 %rh to 85 %rh","cmc":"0,8 %rh"},{"name":"teplota","range":"42 °C to 50 °C","cmc":"0,1 °C"},{"name":"relativní vlhkost","range":"20 %rh to 60 %rh","cmc":"0,8 %rh"}],"regulatory_area_cs":"Relativní vlhkost","search_cs":"Vlhkoměry Termohygrometry Kalibrace — Relativní vlhkost Vnitřní postup; Nepřímá metoda Přímá metoda; Ve stálé lokalitě (S) Relativní vlhkost Vnitřní postup Nepřímá metoda Přímá metoda Ve stálé lokalitě (S) teplota relativní vlhkost teplota relativní vlhkost teplota relativní vlhkost teplota relativní vlhkost teplota relativní vlhkost teplota relativní vlhkost PT 09/100","technique_cs":"Vnitřní postup; Nepřímá metoda\nPřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda\nPřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Vlhkoměry\nTermohygrometry"},{"_id":"be38ef4b43721839ee7cee5b","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Wagi nieautomatyczne elektroniczne\nWagi nieautomatyczne mechaniczne","test_object_en":"Non-automatic electronic weighing instruments\nNon-automatic mechanical weighing instruments","methodology":"Wzorcowanie — Masa (wagi)","methodology_en":"Calibration — Mass (scales)","parameters":[{"name":"","range":"do 1020 g","cmc":"1,8 · 10⁻⁴ %"},{"name":"","range":"1020 g do 9000 g","cmc":"4,6 · 10⁻⁴ %"},{"name":"","range":"9 kg do 31 kg","cmc":"1,3 · 10⁻³ %"}],"parameters_en":[{"name":"","range":"up 1020 g","cmc":"1,8 · 10⁻⁴ %"},{"name":"","range":"1020 g to 9000 g","cmc":"4,6 · 10⁻⁴ %"},{"name":"","range":"9 kg to 31 kg","cmc":"1,3 · 10⁻³ %"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (wagi)\nZakres:\ndo 1020 g CMC 1,8 · 10⁻⁴ %\n1020 g do 9000 g CMC 4,6 · 10⁻⁴ %\n9 kg do 31 kg CMC 1,3 · 10⁻³ %\nW stałej lokalizacji (S) i poza nią (P)","reference":"Euramet cg-18 v. 4.0","norm_bases":["Euramet cg-18 v. 4.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (wagi)","regulatory_area_en":"Mass (scales)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Wagi nieautomatyczne elektroniczne\nWagi nieautomatyczne mechaniczne Wzorcowanie — Masa (wagi)\nZakres:\ndo 1020 g CMC 1,8 · 10⁻⁴ %\n1020 g do 9000 g CMC 4,6 · 10⁻⁴ %\n9 kg do 31 kg CMC 1,3 · 10⁻³ %\nW stałej lokalizacji (S) i poza nią (P) Euramet cg-18 v. 4.0 Wagi nieautomatyczne elektroniczne\nWagi nieautomatyczne mechaniczne Wzorcowanie — Masa (wagi)\nZakres:\ndo 1020 g CMC 1,8 · 10⁻⁴ %\n1020 g do 9000 g CMC 4,6 · 10⁻⁴ %\n9 kg do 31 kg CMC 1,3 · 10⁻³ %\nW stalej lokalizacji (S) i poza nia (P) Euramet cg-18 v. 4.0","search_en":"Non-automatic electronic weighing instruments Non-automatic mechanical weighing instruments Calibration — Mass (scales) At permanent location (S) and outside of it (P) Mass (scales) At permanent location (S) and outside of it (P) Euramet cg-18 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Masse (Waagen)","parameters_de":[{"name":"","range":"up 1020 g","cmc":"1,8 · 10⁻⁴ %"},{"name":"","range":"1020 g to 9000 g","cmc":"4,6 · 10⁻⁴ %"},{"name":"","range":"9 kg to 31 kg","cmc":"1,3 · 10⁻³ %"}],"regulatory_area_de":"Masse (Waagen)","search_de":"Nichtselbsttätige elektronische Waagen Nichtselbsttätige mechanische Waagen Kalibrierung — Masse (Waagen) Am festen Standort (S) und außerhalb (P) Masse (Waagen) Am festen Standort (S) und außerhalb (P) Euramet cg-18 v. 4.0","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Nichtselbsttätige elektronische Waagen\nNichtselbsttätige mechanische Waagen","methodology_zh":"校准 — 质量（衡器）","parameters_zh":[{"name":"","range":"up 1020 g","cmc":"1,8 · 10⁻⁴ %"},{"name":"","range":"1020 g to 9000 g","cmc":"4,6 · 10⁻⁴ %"},{"name":"","range":"9 kg to 31 kg","cmc":"1,3 · 10⁻³ %"}],"regulatory_area_zh":"质量（衡器）","search_zh":"非自动电子衡器 机械式非自动衡器 校准 — 质量（衡器） 在固定地点 (S) 及固定地点以外 (P) 质量（衡器） 在固定地点 (S) 及固定地点以外 (P) Euramet cg-18 v. 4.0","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"非自动电子衡器\n机械式非自动衡器","methodology_cs":"Kalibrace — Hmotnost (váhy)","parameters_cs":[{"name":"","range":"up 1020 g","cmc":"1,8 · 10⁻⁴ %"},{"name":"","range":"1020 g to 9000 g","cmc":"4,6 · 10⁻⁴ %"},{"name":"","range":"9 kg to 31 kg","cmc":"1,3 · 10⁻³ %"}],"regulatory_area_cs":"Hmotnost (váhy)","search_cs":"Elektronické váhy s neautomatickou činností Mechanické váhy s neautomatickou činností Kalibrace — Hmotnost (váhy) V trvalé lokalitě (S) i mimo ni (P) Hmotnost (váhy) V trvalé lokalitě (S) i mimo ni (P) Euramet cg-18 v. 4.0","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Elektronické váhy s neautomatickou činností\nMechanické váhy s neautomatickou činností"},{"_id":"0890a3ea6ce28bc3eaf7c339","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Ciśnieniomierze elektroniczne\nCiśnieniomierze sprężynowe\nBarometry","test_object_en":"Digital manometers\nPressure gauges\nBarometers","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"700 hPa do 1100 hPa","cmc":"0,25 hPa"}],"parameters_en":[{"name":"","range":"700 hPa to 1100 hPa","cmc":"0,25 hPa"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\n700 hPa do 1100 hPa CMC 0,25 hPa\nW stałej lokalizacji (S)","reference":"Euramet cg-17 v. 4.1 pkt. 5.2.1 pkt. 5.2.2","norm_bases":["Euramet cg-17 v. 4.1"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Ciśnieniomierze elektroniczne\nCiśnieniomierze sprężynowe\nBarometry Wzorcowanie — Ciśnienie\n700 hPa do 1100 hPa CMC 0,25 hPa\nW stałej lokalizacji (S) Euramet cg-17 v. 4.1 pkt. 5.2.1 pkt. 5.2.2 Cisnieniomierze elektroniczne\nCisnieniomierze sprezynowe\nBarometry Wzorcowanie — Cisnienie\n700 hPa do 1100 hPa CMC 0,25 hPa\nW stalej lokalizacji (S) Euramet cg-17 v. 4.1 pkt. 5.2.1 pkt. 5.2.2","search_en":"Digital manometers Pressure gauges Barometers Calibration — Pressure At permanent location (S) Pressure At permanent location (S) Euramet cg-17 v. 4.1 point 5.2.1 point 5.2.2","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Euramet cg-17 v. 4.1 point 5.2.1 point 5.2.2","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"700 hPa to 1100 hPa","cmc":"0,25 hPa"}],"reference_de":"Euramet cg-17 v. 4.1 Pkt. 5.2.1 Pkt. 5.2.2","regulatory_area_de":"Druck","search_de":"Elektronische Druckmessgeräte Federmanometer Barometer Kalibrierung — Druck Am festen Standort (S) Druck Am festen Standort (S) Euramet cg-17 v. 4.1 Pkt. 5.2.1 Pkt. 5.2.2","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Elektronische Druckmessgeräte\nFedermanometer\nBarometer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"700 hPa to 1100 hPa","cmc":"0,25 hPa"}],"reference_zh":"Euramet cg-17 v. 4.1 第5.2.1点 第5.2.2点","regulatory_area_zh":"压力","search_zh":"电子压力计 弹簧管压力表 气压计 校准 — 压力 在固定地点 (S) 压力 在固定地点 (S) Euramet cg-17 v. 4.1 第5.2.1点 第5.2.2点","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"电子压力计\n弹簧管压力表\n气压计","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"700 hPa to 1100 hPa","cmc":"0,25 hPa"}],"reference_cs":"Euramet cg-17 v. 4.1 bod 5.2.1 bod 5.2.2","regulatory_area_cs":"Tlak","search_cs":"Elektronické tlakoměry Deformační tlakoměry Barometry Kalibrace — Tlak Ve stálé lokalitě (S) Tlak Ve stálé lokalitě (S) Euramet cg-17 v. 4.1 bod 5.2.1 bod 5.2.2","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Elektronické tlakoměry\nDeformační tlakoměry\nBarometry"},{"_id":"e1c09c3e9305d81a4830d634","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Komory klimatyczne\nKomory termostatyczne","test_object_en":"Climatic chambers\nThermostatic chambers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electric thermometry)","parameters":[{"name":"","range":"-80 °C do 180 °C","cmc":"0,3 °C2)"},{"name":"","range":"180 °C do 250 °C","cmc":"1 °C2)"}],"parameters_en":[{"name":"","range":"-80 °C to 180 °C","cmc":"0,3 °C2)"},{"name":"","range":"180 °C to 250 °C","cmc":"1 °C2)"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do 180 °C CMC 0,3 °C2)\n180 °C do 250 °C CMC 1 °C2)\nW stałej lokalizacji (S) i poza nią (P)","reference":"Euramet cg-20 v. 5.0","norm_bases":["Euramet cg-20 v. 5.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electric thermometry)","outside_premises":true,"location_of_activity":"S, P","note":"2) Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni pomiarowej.","note_en":"2) The measurement uncertainty value for CMC refers to a single point in the measurement space of the calibrated object.","search_text":"Komory klimatyczne\nKomory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do 180 °C CMC 0,3 °C2)\n180 °C do 250 °C CMC 1 °C2)\nW stałej lokalizacji (S) i poza nią (P) Euramet cg-20 v. 5.0 Komory klimatyczne\nKomory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do 180 °C CMC 0,3 °C2)\n180 °C do 250 °C CMC 1 °C2)\nW stalej lokalizacji (S) i poza nia (P) Euramet cg-20 v. 5.0","search_en":"Climatic chambers Thermostatic chambers Calibration — Temperature (electric thermometry) At permanent location (S) and outside of it (P) Temperature (electric thermometry) At permanent location (S) and outside of it (P) Euramet cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":19,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to 180 °C","cmc":"0,3 °C2)"},{"name":"","range":"180 °C to 250 °C","cmc":"1 °C2)"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Klimakammern Thermostatkammern Kalibrierung — Temperatur (elektrische Thermometrie) Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Am festen Standort (S) und außerhalb (P) Euramet cg-20 v. 5.0","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Klimakammern\nThermostatkammern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C to 180 °C","cmc":"0,3 °C2)"},{"name":"","range":"180 °C to 250 °C","cmc":"1 °C2)"}],"regulatory_area_zh":"温度（电测温）","search_zh":"气候箱 恒温箱 校准 — 温度（电测温） 在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 在固定地点 (S) 及固定地点以外 (P) Euramet cg-20 v. 5.0","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"气候箱\n恒温箱","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to 180 °C","cmc":"0,3 °C2)"},{"name":"","range":"180 °C to 250 °C","cmc":"1 °C2)"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Klimatické komory Termostatické komory Kalibrace — Teplota (elektrická termometrie) V trvalé lokalitě (S) i mimo ni (P) Teplota (elektrická termometrie) V trvalé lokalitě (S) i mimo ni (P) Euramet cg-20 v. 5.0","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Klimatické komory\nTermostatické komory"},{"_id":"ae12291427a0dc58a83abafe","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Termostaty cieczowe","test_object_en":"Liquid baths","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electric thermometry)","parameters":[{"name":"","range":"-40 °C do 250 °C","cmc":"0,3 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 250 °C","cmc":"0,3 °C"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-40 °C do 250 °C CMC 0,3 °C\nW stałej lokalizacji (S) i poza nią (P)","reference":"Euramet cg-13 v. 4.0","norm_bases":["Euramet cg-13 v. 4.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electric thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-40 °C do 250 °C CMC 0,3 °C\nW stałej lokalizacji (S) i poza nią (P) Euramet cg-13 v. 4.0 Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-40 °C do 250 °C CMC 0,3 °C\nW stalej lokalizacji (S) i poza nia (P) Euramet cg-13 v. 4.0","search_en":"Liquid baths Calibration — Temperature (electric thermometry) At permanent location (S) and outside of it (P) Temperature (electric thermometry) At permanent location (S) and outside of it (P) Euramet cg-13 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":20,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-40 °C to 250 °C","cmc":"0,3 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Flüssigkeitsthermostate Kalibrierung — Temperatur (elektrische Thermometrie) Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Am festen Standort (S) und außerhalb (P) Euramet cg-13 v. 4.0","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Flüssigkeitsthermostate","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-40 °C to 250 °C","cmc":"0,3 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"液体恒温槽 校准 — 温度（电测温） 在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 在固定地点 (S) 及固定地点以外 (P) Euramet cg-13 v. 4.0","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"液体恒温槽","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-40 °C to 250 °C","cmc":"0,3 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Kapalinové termostaty Kalibrace — Teplota (elektrická termometrie) V trvalé lokalitě (S) i mimo ni (P) Teplota (elektrická termometrie) V trvalé lokalitě (S) i mimo ni (P) Euramet cg-13 v. 4.0","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kapalinové termostaty"},{"_id":"d1b6982bd3b21342d659a6e6","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Piece","test_object_en":"Furnaces","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electric thermometry)","parameters":[{"name":"","range":"30 °C do 170 °C","cmc":"0,5 °C"},{"name":"","range":"171 °C do 1100 °C","cmc":"1,8 °C"}],"parameters_en":[{"name":"","range":"30 °C to 170 °C","cmc":"0,5 °C"},{"name":"","range":"171 °C to 1100 °C","cmc":"1,8 °C"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n30 °C do 170 °C CMC 0,5 °C\n171 °C do 1100 °C CMC 1,8 °C\nW stałej lokalizacji (S) i poza nią (P)","reference":"Euramet cg-13 v. 4.0","norm_bases":["Euramet cg-13 v. 4.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electric thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Piece Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n30 °C do 170 °C CMC 0,5 °C\n171 °C do 1100 °C CMC 1,8 °C\nW stałej lokalizacji (S) i poza nią (P) Euramet cg-13 v. 4.0 Piece Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n30 °C do 170 °C CMC 0,5 °C\n171 °C do 1100 °C CMC 1,8 °C\nW stalej lokalizacji (S) i poza nia (P) Euramet cg-13 v. 4.0","search_en":"Furnaces Calibration — Temperature (electric thermometry) At permanent location (S) and outside of it (P) Temperature (electric thermometry) At permanent location (S) and outside of it (P) Euramet cg-13 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":21,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"30 °C to 170 °C","cmc":"0,5 °C"},{"name":"","range":"171 °C to 1100 °C","cmc":"1,8 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Öfen Kalibrierung — Temperatur (elektrische Thermometrie) Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Am festen Standort (S) und außerhalb (P) Euramet cg-13 v. 4.0","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Öfen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"30 °C to 170 °C","cmc":"0,5 °C"},{"name":"","range":"171 °C to 1100 °C","cmc":"1,8 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"炉具 校准 — 温度（电测温） 在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 在固定地点 (S) 及固定地点以外 (P) Euramet cg-13 v. 4.0","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"炉具","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"30 °C to 170 °C","cmc":"0,5 °C"},{"name":"","range":"171 °C to 1100 °C","cmc":"1,8 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Pece Kalibrace — Teplota (elektrická termometrie) V trvalé lokalitě (S) i mimo ni (P) Teplota (elektrická termometrie) V trvalé lokalitě (S) i mimo ni (P) Euramet cg-13 v. 4.0","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Pece"},{"_id":"57e2f0ff2954b429019cfc72","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (data loggers)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electric thermometry)","parameters":[{"name":"","range":"-40 °C do 80 °C","cmc":"0,1 °C"},{"name":"","range":"80 °C do 180 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 80 °C","cmc":"0,1 °C"},{"name":"","range":"80 °C to 180 °C","cmc":"0,2 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w komorze klimatycznej; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method\nCalibration in the climate chamber; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia\nWzorcowanie w komorze klimatycznej","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method\nCalibration in the climate chamber","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-40 °C do 80 °C CMC 0,1 °C\n80 °C do 180 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w komorze klimatycznej; W stałej lokalizacji (S)","reference":"PT 05/100","norm_bases":["PT 05/100"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electric thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-40 °C do 80 °C CMC 0,1 °C\n80 °C do 180 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w komorze klimatycznej; W stałej lokalizacji (S) PT 05/100 Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-40 °C do 80 °C CMC 0,1 °C\n80 °C do 180 °C CMC 0,2 °C\nProcedura wewnetrzna; Metoda bezposrednia\nWzorcowanie w komorze klimatycznej; W stalej lokalizacji (S) PT 05/100","search_en":"Electrical thermometers (including electronic) Electrical thermometers (data loggers) Calibration — Temperature (electric thermometry) Internal procedure; Direct method Calibration in the climate chamber; At permanent location (S) Temperature (electric thermometry) Internal procedure Direct method Calibration in the climate chamber At permanent location (S) PT 05/100","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":22,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-40 °C to 80 °C","cmc":"0,1 °C"},{"name":"","range":"80 °C to 180 °C","cmc":"0,2 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren Kalibrierung in einer Klimakammer; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Kalibrierung in einer Klimakammer Am festen Standort (S) PT 05/100","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren\nKalibrierung in einer Klimakammer; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren\nKalibrierung in einer Klimakammer","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-40 °C to 80 °C","cmc":"0,1 °C"},{"name":"","range":"80 °C to 180 °C","cmc":"0,2 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序；直接法 在气候箱中校准；在固定地点 (S) 温度（电测温） 内部程序 直接法 在气候箱中校准 在固定地点 (S) PT 05/100","technique_zh":"内部程序；直接法\n在气候箱中校准；在固定地点 (S)","techniques_zh":["内部程序","直接法\n在气候箱中校准","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-40 °C to 80 °C","cmc":"0,1 °C"},{"name":"","range":"80 °C to 180 °C","cmc":"0,2 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda Kalibrace v klimatické komoře; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Kalibrace v klimatické komoře Ve stálé lokalitě (S) PT 05/100","technique_cs":"Vnitřní postup; Přímá metoda\nKalibrace v klimatické komoře; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda\nKalibrace v klimatické komoře","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"},{"_id":"65c3233a85778c3dfde49b09","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (data loggers)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electric thermometry)","parameters":[{"name":"","range":"-80 °C do 180 °C","cmc":"0,03 °C"}],"parameters_en":[{"name":"","range":"-80 °C to 180 °C","cmc":"0,03 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w termostacie cieczowym; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method\nCalibration in a liquid thermostat; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia\nWzorcowanie w termostacie cieczowym","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method\nCalibration in a liquid thermostat","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 180 °C CMC 0,03 °C\nProcedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w termostacie cieczowym; W stałej lokalizacji (S)","reference":"PT 05/100","norm_bases":["PT 05/100"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electric thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 180 °C CMC 0,03 °C\nProcedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w termostacie cieczowym; W stałej lokalizacji (S) PT 05/100 Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 180 °C CMC 0,03 °C\nProcedura wewnetrzna; Metoda bezposrednia\nWzorcowanie w termostacie cieczowym; W stalej lokalizacji (S) PT 05/100","search_en":"Electrical thermometers (including electronic) Electrical thermometers (data loggers) Calibration — Temperature (electric thermometry) Internal procedure; Direct method Calibration in a liquid thermostat; At permanent location (S) Temperature (electric thermometry) Internal procedure Direct method Calibration in a liquid thermostat At permanent location (S) PT 05/100","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":23,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to 180 °C","cmc":"0,03 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren Kalibrierung in einem Flüssigkeitsthermostat; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Kalibrierung im Flüssigkeitsthermostat Am festen Standort (S) PT 05/100","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren\nKalibrierung in einem Flüssigkeitsthermostat; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren\nKalibrierung im Flüssigkeitsthermostat","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C to 180 °C","cmc":"0,03 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序；直接法 在液体恒温槽中校准；在固定地点 (S) 温度（电测温） 内部程序 直接法 在液体恒温槽中校准 在固定地点 (S) PT 05/100","technique_zh":"内部程序；直接法\n在液体恒温槽中校准；在固定地点 (S)","techniques_zh":["内部程序","直接法\n在液体恒温槽中校准","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to 180 °C","cmc":"0,03 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda Kalibrace v kapalinovém termostatu; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Kalibrace v kapalinovém termostatu Ve stálé lokalitě (S) PT 05/100","technique_cs":"Vnitřní postup; Přímá metoda\nKalibrace v kapalinovém termostatu; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda\nKalibrace v kapalinovém termostatu","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"},{"_id":"7cc537bbec9147f5997a054e","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (data loggers)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electric thermometry)","parameters":[{"name":"","range":"-100 °C do -80 °C","cmc":"0,5 °C"},{"name":"","range":"-80 °C do 30 °C","cmc":"0,2 °C"},{"name":"","range":"30 °C do 250 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"","range":"-100 °C to -80 °C","cmc":"0,5 °C"},{"name":"","range":"-80 °C to 30 °C","cmc":"0,2 °C"},{"name":"","range":"30 °C to 250 °C","cmc":"0,2 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w kalibratorze temperatury; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method\nCalibration in the temperature calibrator; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia\nWzorcowanie w kalibratorze temperatury","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method\nCalibration in the temperature calibrator","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do -80 °C CMC 0,5 °C\n-80 °C do 30 °C CMC 0,2 °C\n30 °C do 250 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w kalibratorze temperatury; W stałej lokalizacji (S) i poza nią (P)","reference":"PT 05/100","norm_bases":["PT 05/100"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electric thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do -80 °C CMC 0,5 °C\n-80 °C do 30 °C CMC 0,2 °C\n30 °C do 250 °C CMC 0,2 °C\nProcedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w kalibratorze temperatury; W stałej lokalizacji (S) i poza nią (P) PT 05/100 Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do -80 °C CMC 0,5 °C\n-80 °C do 30 °C CMC 0,2 °C\n30 °C do 250 °C CMC 0,2 °C\nProcedura wewnetrzna; Metoda bezposrednia\nWzorcowanie w kalibratorze temperatury; W stalej lokalizacji (S) i poza nia (P) PT 05/100","search_en":"Electrical thermometers (including electronic) Electrical thermometers (data loggers) Calibration — Temperature (electric thermometry) Internal procedure; Direct method Calibration in the temperature calibrator; At permanent location (S) and outside of it (P) Temperature (electric thermometry) Internal procedure Direct method Calibration in the temperature calibrator At permanent location (S) and outside of it (P) PT 05/100","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":24,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C to -80 °C","cmc":"0,5 °C"},{"name":"","range":"-80 °C to 30 °C","cmc":"0,2 °C"},{"name":"","range":"30 °C to 250 °C","cmc":"0,2 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren Kalibrierung im Temperaturkalibrator; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Kalibrierung im Temperaturkalibrator Am festen Standort (S) und außerhalb (P) PT 05/100","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren\nKalibrierung im Temperaturkalibrator; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren\nKalibrierung im Temperaturkalibrator","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C to -80 °C","cmc":"0,5 °C"},{"name":"","range":"-80 °C to 30 °C","cmc":"0,2 °C"},{"name":"","range":"30 °C to 250 °C","cmc":"0,2 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序；直接法 在温度校准器中校准；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 直接法 在温度校准器中校准 在固定地点 (S) 及固定地点以外 (P) PT 05/100","technique_zh":"内部程序；直接法\n在温度校准器中校准；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法\n在温度校准器中校准","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C to -80 °C","cmc":"0,5 °C"},{"name":"","range":"-80 °C to 30 °C","cmc":"0,2 °C"},{"name":"","range":"30 °C to 250 °C","cmc":"0,2 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda Kalibrace v kalibrátoru teploty; V trvalé lokalitě (S) i mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Kalibrace v kalibrátoru teploty V trvalé lokalitě (S) i mimo ni (P) PT 05/100","technique_cs":"Vnitřní postup; Přímá metoda\nKalibrace v kalibrátoru teploty; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda\nKalibrace v kalibrátoru teploty","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"},{"_id":"49943004a60c5812ce441d15","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (data loggers)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electric thermometry)","parameters":[{"name":"","range":"250°C do 660 °C","cmc":"0,2 °C"},{"name":"","range":"660°C do 700 °C","cmc":"0,8 °C"},{"name":"","range":"700°C do 1100 °C","cmc":"2,1 °C"}],"parameters_en":[{"name":"","range":"250°C to 660 °C","cmc":"0,2 °C"},{"name":"","range":"660°C to 700 °C","cmc":"0,8 °C"},{"name":"","range":"700°C to 1100 °C","cmc":"2,1 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w kalibratorze temperatury; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method\nCalibration in the temperature calibrator; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia\nWzorcowanie w kalibratorze temperatury","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method\nCalibration in the temperature calibrator","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n250°C do 660 °C CMC 0,2 °C\n660°C do 700 °C CMC 0,8 °C\n700°C do 1100 °C CMC 2,1 °C\nProcedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w kalibratorze temperatury; W stałej lokalizacji (S)","reference":"PT 05/100","norm_bases":["PT 05/100"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electric thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n250°C do 660 °C CMC 0,2 °C\n660°C do 700 °C CMC 0,8 °C\n700°C do 1100 °C CMC 2,1 °C\nProcedura wewnętrzna; Metoda bezpośrednia\nWzorcowanie w kalibratorze temperatury; W stałej lokalizacji (S) PT 05/100 Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n250°C do 660 °C CMC 0,2 °C\n660°C do 700 °C CMC 0,8 °C\n700°C do 1100 °C CMC 2,1 °C\nProcedura wewnetrzna; Metoda bezposrednia\nWzorcowanie w kalibratorze temperatury; W stalej lokalizacji (S) PT 05/100","search_en":"Electrical thermometers (including electronic) Electrical thermometers (data loggers) Calibration — Temperature (electric thermometry) Internal procedure; Direct method Calibration in the temperature calibrator; At permanent location (S) Temperature (electric thermometry) Internal procedure Direct method Calibration in the temperature calibrator At permanent location (S) PT 05/100","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":25,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"250°C to 660 °C","cmc":"0,2 °C"},{"name":"","range":"660°C to 700 °C","cmc":"0,8 °C"},{"name":"","range":"700°C to 1100 °C","cmc":"2,1 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren Kalibrierung im Temperaturkalibrator; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Kalibrierung im Temperaturkalibrator Am festen Standort (S) PT 05/100","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren\nKalibrierung im Temperaturkalibrator; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren\nKalibrierung im Temperaturkalibrator","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"250°C to 660 °C","cmc":"0,2 °C"},{"name":"","range":"660°C to 700 °C","cmc":"0,8 °C"},{"name":"","range":"700°C to 1100 °C","cmc":"2,1 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序；直接法 在温度校准器中校准；在固定地点 (S) 温度（电测温） 内部程序 直接法 在温度校准器中校准 在固定地点 (S) PT 05/100","technique_zh":"内部程序；直接法\n在温度校准器中校准；在固定地点 (S)","techniques_zh":["内部程序","直接法\n在温度校准器中校准","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"250°C to 660 °C","cmc":"0,2 °C"},{"name":"","range":"660°C to 700 °C","cmc":"0,8 °C"},{"name":"","range":"700°C to 1100 °C","cmc":"2,1 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda Kalibrace v kalibrátoru teploty; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Kalibrace v kalibrátoru teploty Ve stálé lokalitě (S) PT 05/100","technique_cs":"Vnitřní postup; Přímá metoda\nKalibrace v kalibrátoru teploty; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda\nKalibrace v kalibrátoru teploty","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"},{"_id":"a1933ca4d6ad960982075b4d","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Termometry szklane cieczowe","test_object_en":"Liquid in glass thermometers","methodology":"Wzorcowanie — Temperatura (termometria nieelektryczna)","methodology_en":"Calibration — Temperature (non-electric thermometry)","parameters":[{"name":"","range":"-40 °C do 180 °C","cmc":"0,04 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 180 °C","cmc":"0,04 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria nieelektryczna)\n-40 °C do 180 °C CMC 0,04 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PT 05/100","norm_bases":["PT 05/100"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria nieelektryczna)","regulatory_area_en":"Temperature (non-electric thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry szklane cieczowe Wzorcowanie — Temperatura (termometria nieelektryczna)\n-40 °C do 180 °C CMC 0,04 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PT 05/100 Termometry szklane cieczowe Wzorcowanie — Temperatura (termometria nieelektryczna)\n-40 °C do 180 °C CMC 0,04 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PT 05/100","search_en":"Liquid in glass thermometers Calibration — Temperature (non-electric thermometry) Internal procedure; At permanent location (S) Temperature (non-electric thermometry) Internal procedure At permanent location (S) PT 05/100","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":26,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (nichtelektrische Thermometrie)","parameters_de":[{"name":"","range":"-40 °C to 180 °C","cmc":"0,04 °C"}],"regulatory_area_de":"Temperatur (nichtelektrische Thermometrie)","search_de":"Flüssigkeits-Glasthermometer Kalibrierung — Temperatur (nichtelektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (nichtelektrische Thermometrie) Internes Verfahren Am festen Standort (S) PT 05/100","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Flüssigkeits-Glasthermometer","methodology_zh":"校准 — 温度（非电测温）","parameters_zh":[{"name":"","range":"-40 °C to 180 °C","cmc":"0,04 °C"}],"regulatory_area_zh":"温度（非电测温）","search_zh":"玻璃液体温度计 校准 — 温度（非电测温） 内部程序；在固定地点 (S) 温度（非电测温） 内部程序 在固定地点 (S) PT 05/100","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"玻璃液体温度计","methodology_cs":"Kalibrace — Teplota (neelektrická termometrie)","parameters_cs":[{"name":"","range":"-40 °C to 180 °C","cmc":"0,04 °C"}],"regulatory_area_cs":"Teplota (neelektrická termometrie)","search_cs":"Skleněné kapalinové teploměry Kalibrace — Teplota (neelektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (neelektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PT 05/100","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Skleněné kapalinové teploměry"},{"_id":"9b6db39145aee12f34d4a249","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Pirometry","test_object_en":"Pyrometers","methodology":"Wzorcowanie — Temperatura (termometria radiacyjna)","methodology_en":"Calibration — Temperature (radiation thermometry)","parameters":[{"name":"","range":"-15 °C do 0 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C do 120 °C","cmc":"1,4 °C"},{"name":"","range":"120 °C do 300 °C","cmc":"2,6 °C"},{"name":"","range":"300 °C do 500 °C","cmc":"2,8 °C"}],"parameters_en":[{"name":"","range":"-15 °C do 0 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C to 120 °C","cmc":"1,4 °C"},{"name":"","range":"120 °C do 300 °C","cmc":"2,6 °C"},{"name":"","range":"300 °C do 500 °C","cmc":"2,8 °C"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-15 °C do 0 °C CMC 1,6 °C\n0 °C do 120 °C CMC 1,4 °C\n120 °C do 300 °C CMC 2,6 °C\n300 °C do 500 °C CMC 2,8 °C\nW stałej lokalizacji (S)","reference":"VDI/VDE 3511 Part 4.4","norm_bases":["VDI/VDE 3511 Part 4.4"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria radiacyjna)","regulatory_area_en":"Temperature (radiation thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pirometry Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-15 °C do 0 °C CMC 1,6 °C\n0 °C do 120 °C CMC 1,4 °C\n120 °C do 300 °C CMC 2,6 °C\n300 °C do 500 °C CMC 2,8 °C\nW stałej lokalizacji (S) VDI/VDE 3511 Part 4.4 Pirometry Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-15 °C do 0 °C CMC 1,6 °C\n0 °C do 120 °C CMC 1,4 °C\n120 °C do 300 °C CMC 2,6 °C\n300 °C do 500 °C CMC 2,8 °C\nW stalej lokalizacji (S) VDI/VDE 3511 Part 4.4","search_en":"Pyrometers Calibration — Temperature (radiation thermometry) At permanent location (S) Temperature (radiation thermometry) At permanent location (S) VDI/VDE 3511 Part 4.4","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":27,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (Strahlungsthermometrie)","parameters_de":[{"name":"","range":"-15 °C do 0 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C bis 120 °C","cmc":"1,4 °C"},{"name":"","range":"120 °C do 300 °C","cmc":"2,6 °C"},{"name":"","range":"300 °C do 500 °C","cmc":"2,8 °C"}],"regulatory_area_de":"Temperatur (Strahlungsthermometrie)","search_de":"Pyrometer Kalibrierung — Temperatur (Strahlungsthermometrie) Am festen Standort (S) Temperatur (Strahlungsthermometrie) Am festen Standort (S) VDI/VDE 3511 Part 4.4","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Pyrometer","methodology_zh":"校准 — 温度（辐射测温）","parameters_zh":[{"name":"","range":"-15 °C do 0 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C 至 120 °C","cmc":"1,4 °C"},{"name":"","range":"120 °C do 300 °C","cmc":"2,6 °C"},{"name":"","range":"300 °C do 500 °C","cmc":"2,8 °C"}],"regulatory_area_zh":"温度（辐射测温）","search_zh":"高温计 校准 — 温度（辐射测温） 在固定地点 (S) 温度（辐射测温） 在固定地点 (S) VDI/VDE 3511 Part 4.4","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"高温计","methodology_cs":"Kalibrace — Teplota (radiační termometrie)","parameters_cs":[{"name":"","range":"-15 °C do 0 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C do 120 °C","cmc":"1,4 °C"},{"name":"","range":"120 °C do 300 °C","cmc":"2,6 °C"},{"name":"","range":"300 °C do 500 °C","cmc":"2,8 °C"}],"regulatory_area_cs":"Teplota (radiační termometrie)","search_cs":"Pyrometry Kalibrace — Teplota (radiační termometrie) Ve stálé lokalitě (S) Teplota (radiační termometrie) Ve stálé lokalitě (S) VDI/VDE 3511 Part 4.4","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Pyrometry"},{"_id":"d2987fc931e634bdc550feab","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Pipety tłokowe\nBiurety tłokowe\nDozowniki","test_object_en":"Piston pipettes\nPiston burettes\nDispensers","methodology":"Wzorcowanie — Objętość","methodology_en":"Calibration — Volume","parameters":[{"name":"","range":"0,1 µl do 2,5 µl","cmc":"0,025 µl"},{"name":"","range":"2,5 µl do 20 µl","cmc":"0,040 µl"},{"name":"","range":"20 µl do 200 µl","cmc":"0,30 µl"},{"name":"","range":"200 µl do 1000 µl","cmc":"1,8 µl"},{"name":"","range":"1000 µl do 5000 µl","cmc":"9 µl"},{"name":"","range":"5000 µl do 10000 µl","cmc":"14 µl"},{"name":"","range":"10000 µl do 20000 µl","cmc":"27 µl"}],"parameters_en":[{"name":"","range":"0,1 µl to 2,5 µl","cmc":"0,025 µl"},{"name":"","range":"2,5 µl to 20 µl","cmc":"0,040 µl"},{"name":"","range":"20 µl to 200 µl","cmc":"0,30 µl"},{"name":"","range":"200 µl to 1000 µl","cmc":"1,8 µl"},{"name":"","range":"1000 µl to 5000 µl","cmc":"9 µl"},{"name":"","range":"5000 µl to 10000 µl","cmc":"14 µl"},{"name":"","range":"10000 µl to 20000 µl","cmc":"27 µl"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Objętość\nZakres:\n0,1 µl do 2,5 µl CMC 0,025 µl\n2,5 µl do 20 µl CMC 0,040 µl\n20 µl do 200 µl CMC 0,30 µl\n200 µl do 1000 µl CMC 1,8 µl\n1000 µl do 5000 µl CMC 9 µl\n5000 µl do 10000 µl CMC 14 µl\n10000 µl do 20000 µl CMC 27 µl\nW stałej lokalizacji (S)","reference":"PN-EN ISO 8655-6:2022-11","norm_bases":["PN-EN ISO 8655-6:2022-11"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Objętość","regulatory_area_en":"Volume","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pipety tłokowe\nBiurety tłokowe\nDozowniki Wzorcowanie — Objętość\nZakres:\n0,1 µl do 2,5 µl CMC 0,025 µl\n2,5 µl do 20 µl CMC 0,040 µl\n20 µl do 200 µl CMC 0,30 µl\n200 µl do 1000 µl CMC 1,8 µl\n1000 µl do 5000 µl CMC 9 µl\n5000 µl do 10000 µl CMC 14 µl\n10000 µl do 20000 µl CMC 27 µl\nW stałej lokalizacji (S) PN-EN ISO 8655-6:2022-11 Pipety tlokowe\nBiurety tlokowe\nDozowniki Wzorcowanie — Objetosc\nZakres:\n0,1 µl do 2,5 µl CMC 0,025 µl\n2,5 µl do 20 µl CMC 0,040 µl\n20 µl do 200 µl CMC 0,30 µl\n200 µl do 1000 µl CMC 1,8 µl\n1000 µl do 5000 µl CMC 9 µl\n5000 µl do 10000 µl CMC 14 µl\n10000 µl do 20000 µl CMC 27 µl\nW stalej lokalizacji (S) PN-EN ISO 8655-6:2022-11","search_en":"Piston pipettes Piston burettes Dispensers Calibration — Volume At permanent location (S) Volume At permanent location (S) PN-EN ISO 8655-6:2022-11","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":28,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Volumen","parameters_de":[{"name":"","range":"0,1 µl to 2,5 µl","cmc":"0,025 µl"},{"name":"","range":"2,5 µl to 20 µl","cmc":"0,040 µl"},{"name":"","range":"20 µl to 200 µl","cmc":"0,30 µl"},{"name":"","range":"200 µl to 1000 µl","cmc":"1,8 µl"},{"name":"","range":"1000 µl to 5000 µl","cmc":"9 µl"},{"name":"","range":"5000 µl to 10000 µl","cmc":"14 µl"},{"name":"","range":"10000 µl to 20000 µl","cmc":"27 µl"}],"regulatory_area_de":"Volumen","search_de":"Kolbenhubpipetten Kolbenbüretten Dosiergeräte Kalibrierung — Volumen Am festen Standort (S) Volumen Am festen Standort (S) PN-EN ISO 8655-6:2022-11","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Kolbenhubpipetten\nKolbenbüretten\nDosiergeräte","methodology_zh":"校准 — 体积","parameters_zh":[{"name":"","range":"0,1 µl to 2,5 µl","cmc":"0,025 µl"},{"name":"","range":"2,5 µl to 20 µl","cmc":"0,040 µl"},{"name":"","range":"20 µl to 200 µl","cmc":"0,30 µl"},{"name":"","range":"200 µl to 1000 µl","cmc":"1,8 µl"},{"name":"","range":"1000 µl to 5000 µl","cmc":"9 µl"},{"name":"","range":"5000 µl to 10000 µl","cmc":"14 µl"},{"name":"","range":"10000 µl to 20000 µl","cmc":"27 µl"}],"regulatory_area_zh":"体积","search_zh":"活塞式移液器 活塞式滴定管 分配器 校准 — 体积 在固定地点 (S) 体积 在固定地点 (S) PN-EN ISO 8655-6:2022-11","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"活塞式移液器\n活塞式滴定管\n分配器","methodology_cs":"Kalibrace — Objem","parameters_cs":[{"name":"","range":"0,1 µl to 2,5 µl","cmc":"0,025 µl"},{"name":"","range":"2,5 µl to 20 µl","cmc":"0,040 µl"},{"name":"","range":"20 µl to 200 µl","cmc":"0,30 µl"},{"name":"","range":"200 µl to 1000 µl","cmc":"1,8 µl"},{"name":"","range":"1000 µl to 5000 µl","cmc":"9 µl"},{"name":"","range":"5000 µl to 10000 µl","cmc":"14 µl"},{"name":"","range":"10000 µl to 20000 µl","cmc":"27 µl"}],"regulatory_area_cs":"Objem","search_cs":"Pístové pipety Pístové byrety Dávkovače Kalibrace — Objem Ve stálé lokalitě (S) Objem Ve stálé lokalitě (S) PN-EN ISO 8655-6:2022-11","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Pístové pipety\nPístové byrety\nDávkovače"},{"_id":"c0485c92b107134cc422a95a","lab_id":"6afa3b8a8989a133b76445aa","country":"PL","accr_number":"AP 021","accr_body":"PCA","test_object":"Biurety tłokowe\nDozowniki","test_object_en":"Piston burettes\nDispensers","methodology":"Wzorcowanie — Objętość","methodology_en":"Calibration — Volume","parameters":[{"name":"","range":"20000 µl do 50000 µl","cmc":"35 µl"}],"parameters_en":[{"name":"","range":"20000 µl to 50000 µl","cmc":"35 µl"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Objętość\n20000 µl do 50000 µl CMC 35 µl\nW stałej lokalizacji (S)","reference":"PN-EN ISO 8655-6:2022-11","norm_bases":["PN-EN ISO 8655-6:2022-11"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Objętość","regulatory_area_en":"Volume","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Biurety tłokowe\nDozowniki Wzorcowanie — Objętość\n20000 µl do 50000 µl CMC 35 µl\nW stałej lokalizacji (S) PN-EN ISO 8655-6:2022-11 Biurety tlokowe\nDozowniki Wzorcowanie — Objetosc\n20000 µl do 50000 µl CMC 35 µl\nW stalej lokalizacji (S) PN-EN ISO 8655-6:2022-11","search_en":"Piston burettes Dispensers Calibration — Volume At permanent location (S) Volume At permanent location (S) PN-EN ISO 8655-6:2022-11","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":29,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Volumen","parameters_de":[{"name":"","range":"20000 µl to 50000 µl","cmc":"35 µl"}],"regulatory_area_de":"Volumen","search_de":"Kolbenbüretten Dosiergeräte Kalibrierung — Volumen Am festen Standort (S) Volumen Am festen Standort (S) PN-EN ISO 8655-6:2022-11","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Kolbenbüretten\nDosiergeräte","methodology_zh":"校准 — 体积","parameters_zh":[{"name":"","range":"20000 µl to 50000 µl","cmc":"35 µl"}],"regulatory_area_zh":"体积","search_zh":"活塞式滴定管 分配器 校准 — 体积 在固定地点 (S) 体积 在固定地点 (S) PN-EN ISO 8655-6:2022-11","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"活塞式滴定管\n分配器","methodology_cs":"Kalibrace — Objem","parameters_cs":[{"name":"","range":"20000 µl to 50000 µl","cmc":"35 µl"}],"regulatory_area_cs":"Objem","search_cs":"Pístové byrety Dávkovače Kalibrace — Objem Ve stálé lokalitě (S) Objem Ve stálé lokalitě (S) PN-EN ISO 8655-6:2022-11","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Pístové byrety\nDávkovače"}],"has_pdf":true}