🇵🇱 Instytut Łączności - Państwowy Instytut Badawczy PL
Metrology & calibration
Instytut Łączności - Państwowy Instytut Badawczy is a calibration laboratory accredited by PCA under number AP 015 (Warszawa, Poland). Its accreditation scope covers 120 calibration items in the following areas: Metrology & calibration. Calibrated items include: Radio communication testers, Data acquisition cards, Power network parameter meters, Bridges. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S) and ou…, Internal procedure; At permanent location (S) and outside of it (P), Internal procedure; Direct method; At permanent location (S).
At a glance
- Accreditation number: PCA AP 015
- Calibration items in scope: 120
- Types of calibrated items: 187
- Calibration principles used: 12
- City: Warszawa, Poland
- Valid until: 20-12-2027
- Accreditation number
- AP 015
- Accreditation body
- PCA
- Address
- ul. Szachowa 1, 04-894 Warszawa
- City
- Warszawa, Poland
- Division
- Laboratory of Electrical, Electronic and Optoelectronic Metrology
- Valid until
- 20-12-2027
What this laboratory calibrates (187)
- Radio communication testers — 14 calibration items
- Data acquisition cards — 13 calibration items
- Power network parameter meters — 9 calibration items
- Bridges — 8 calibration items
- Calibrators — 8 calibration items
- Electrical safety testers — 8 calibration items
- Measuring receivers — 8 calibration items
- Multimeters — 8 calibration items
- Optical time-domain reflectometers (OTDR) — 8 calibration items
- Single-mode optical time-domain reflectometers — 8 calibration items
- Attenuation measurement sets — 7 calibration items
- Electronic loads — 7 calibration items
- Line parameter and fault analysers — 7 calibration items
- Multimode optical time-domain reflectometers — 7 calibration items
- Scopemeters — 7 calibration items
- and 172 more
Calibration principles (12)
- Internal procedure; Direct method; At permanent location (S) and outside of it (P) — 60 calibration items
- Internal procedure; At permanent location (S) and outside of it (P) — 21 calibration items
- Internal procedure; Direct method; At permanent location (S) — 13 calibration items
- Internal procedure; At permanent location (S) — 10 calibration items
- Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) — 5 calibration items
- Internal procedure; Outside of permanent location (P) — 5 calibration items
- Direct method; At permanent location (S) and outside of it (P) — 1 calibration item
- Direct method. Measurement according to the method implemented by instruments based on the OCWR technique and described in PN-EN-61280-4-2:2014-11 Annex E and Annex F; At permanent location (S) and outside of it (P) — 1 calibration item
- Internal procedure; Direct or indirect method; At permanent location (S) and outside of it (P) — 1 calibration item
- Internal procedure; Indirect method; At permanent location (S) and outside of it (P) — 1 calibration item
- Internal procedure; Performed in a liquid bath; At permanent location (S) — 1 calibration item
- Internal procedure; Performed in a temperature calibrator; At permanent location (S) and outside of it (P) — 1 calibration item
Certificate information
- Issue date
- 09.12.2025
- Issue no.
- 23
- Certificate date
- 18.10.2019
- Accreditation cycle
- 21.12.2023 — 20.12.2027
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (120)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Calibrators DC voltage sources Data acquisition cards Power supplies Breakdown testers Electrical safety testers Bridges |
Calibration — DC voltage 0 mV to 5 mV · CMC 6·10⁻⁵ · U + 0,03 µV 5 mV to 10 mV · CMC 7·10⁻⁶ · U + 0,1 µV 10 mV to 200 mV · CMC 6·10⁻⁶ · U + 0,1 µV 0,2 V to 2 V · CMC 4·10⁻⁶ · U + 0,5 µV 2 V to 20 V · CMC 4·10⁻⁶ · U + 5 µV 20 V to 200 V · CMC 5·10⁻⁶ · U + 0,03 mV 200 V to 1000 V · CMC 0,0007 % 1 kV to 10 kV · CMC 0,05 % DC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/35 | |
| 2 | Multimeters Digital voltmeters Analogue voltmeters Data acquisition cards Scopemeters Electronic loads Power network parameter meters Electrical safety testers Measuring probes Voltage dividers RF power meters Line parameter and fault analysers |
Calibration — DC voltage 0 mV to 5 mV · CMC 6·10⁻⁵ · U + 0,03 µV 5 mV to 10 mV · CMC 7·10⁻⁶ · U + 0,1 µV 10 mV to 200 mV · CMC 6·10⁻⁶ · U + 0,1 µV 0,2 V to 2 V · CMC 4·10⁻⁶ · U + 0,5 µV 2 V to 20 V · CMC 4·10⁻⁶ · U + 5 µV 20 V to 200 V · CMC 5·10⁻⁶ · U + 0,03 mV 200 V to 1000 V · CMC 0,0007 % DC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/2 based on EURAMET cg-15 v. 3.0 LMEEiO/33 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53 | |
| 3 | Oscilloscopes Data acquisition cards Internal reference source in oscilloscopes |
Calibration — DC voltage 1 mV to 222 V · CMC 3·10⁻⁴· U + 30 µV internal reference source in oscilloscopes — 0 V to 10 V · CMC 0,001 % DC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/13 based on EURAMET cg-7 v. 1.0 | |
| 4 | Calibrators Data acquisition cards DC current sources Power supplies Power network parameter meters Electrical safety testers Bridges |
Calibration — DC current 0 µA to 100 µA · CMC 4·10⁻⁵ · I + 0,02 nA 100 µA to 10 A · CMC 0,002% 10 A to 100 A · CMC 0,008% 100 A to 500 A · CMC 0,01% 500 A to 1000 A · CMC 0,2% DC current |
Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) | LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/35 | |
| 5 | Digital ammeters Analogue ammeters Multimeters Data acquisition cards Scopemeters Clamp meters Electrical safety testers Power network parameter meters Measuring probes Electronic loads Line parameter and fault analysers |
Calibration — DC current 0 µA to 100 µA · CMC 4·10⁻⁵ · I + 0,02 nA 100 µA to 10 A · CMC 0,002% 10 A to 100 A · CMC 0,008% 100 A to 500 A · CMC 0,01% 500 A to 1000 A · CMC 0,2% DC current |
Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) | LMEEiO/2 based on EURAMET cg-15 v. 3.0 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53 | |
| 6 | Calibrators Data acquisition cards Power supplies Bridges Power network parameter meters Electrical safety testers Breakdown testers RF generators |
Calibration — AC voltage 10 Hz to 40 Hz — 0,1 mV to 5 mV · CMC 3,5·10⁻⁴ · U + 3,5 µV 10 Hz to 40 Hz — 5 mV to 12 mV · CMC 1,5·10⁻⁴ · U + 4,7 µV 10 Hz to 40 Hz — 12 mV to 120 mV · CMC 8·10⁻⁵ · U + 4,7 µ 10 Hz to 40 Hz — 0,12 V to 1,2 V · CMC 8·10⁻⁵ · U + 47 µV 10 Hz to 40 Hz — 1,2 V to 12 V · CMC 8·10⁻⁵ · U + 0,47 m 10 Hz to 40 Hz — 12 V to 20 V · CMC 1,2·10⁻⁴ · U + 0,32 mV 10 Hz to 40 Hz — 20 V to 200V · CMC 1,2·10⁻⁴ · U + 2,5 mV 10 Hz to 40 Hz — 200 V to 1000 V · CMC 1,3·10⁻⁴ · U + 23 mV 20 Hz to 40 Hz — 0,22 V to 2,2 V · CMC 8·10⁻⁵ · U + 22 µV 40 Hz to 50 Hz — 200 V to 1000 V · CMC 1,1·10⁻⁴ · U + 23 mV 40 Hz to 1 kHz — 0,1 mV to 12 mV · CMC 2,4·10⁻⁴ · U + 1,3 µV 40 Hz to 1 kHz — 12 mV to 120 mV · CMC 8,2·10⁻⁵ · U + 2,3 µV 1 kHz to 20 kHz — 0,1 mV to 12 mV · CMC 3,5·10⁻⁴ · U + 1,3 µV 1 kHz to 20 kHz — 12 mV to 120 mV · CMC 1,2·10⁻⁴ · U + 4,6 µV 40 Hz to 20 kHz — 120 mV to 220 mV · CMC 6,7·10⁻⁵ · U + 8,1 µV 40 Hz to 20 kHz — 0,22 V to 2,2 V · CMC 4,2·10⁻⁵ · U + 12 µV 40 Hz to 20 kHz — 2,2 V to 22 V · CMC 5,0·10⁻⁵ · U + 60 µV 40 Hz to 20 kHz — 22 V to 220 V · CMC 6,0·10⁻⁵ · U + 0,8 mV 50 Hz to 1 kHz — 220 V to 1000 V · CMC 8,0·10⁻⁵ · U + 4,5 mV 1 kHz to 10 kHz — 220 V to 1000 V · CMC 1,1·10⁻⁴ · U + 23 mV 10 kHz to 33 kHz — 220 V to 1000 V · CMC 1,9·10⁻⁴ · U + 21 mV 20 kHz to 50 kHz — 0,1 mV to 2,2 mV · CMC 3,0·10⁻⁴ · U + 4,6 µV 20 kHz to 50 kHz — 2,2 mV to 22 mV · CMC 2,3·10⁻⁴ · U + 4,7 µV 20 kHz to 50 kHz — 22 mV to 220 mV · CMC 1,4·10⁻⁵ · U + 9 µV 20 kHz to 50 kHz — 0,22 V to 2,2 V · CMC 7,6·10⁻⁵ · U + 13 µV 20 kHz to 50 kHz — 2,2 V to 22 V · CMC 7,8·10⁻⁵ · U + 0,12 mV 20 kHz to 50 kHz — 22 V to 220 V · CMC 9,2·10⁻⁵ · U + 1,2 mV 33 kHz to 100 kHz — 220 V to 1000 V · CMC 6,0·10⁻⁴ · U + 0,23 V 50 kHz to 100 kHz — 0,1 mV to 2,2 mV · CMC 5,0·10⁻⁴ · U + 6 µV 50 kHz to 100 kHz — 2,2 mV to 22 mV · CMC 6,0·10⁻⁴ · U + 5,7 µV 50 kHz to 100 kHz — 22 mV to 220 mV · CMC 3,6·10⁻⁴ · U + 20 µV 50 kHz to 100 kHz — 0,22 V to 2,2 V · CMC 1,0·10⁻⁴ · U + 34 µV 50 kHz to 100 kHz — 2,2 V to 22 V · CMC 9,5·10⁻⁵ · U + 0,23 mV 50 kHz to 100 kHz — 22 V to 220 V · CMC 1,8·10⁻⁴ · U + 2,7 mV 100 kHz to 300 kHz — 0,1 mV to 2,2 mV · CMC 5,0·10⁻⁴ · U + 6 µV 100 kHz to 300 kHz — 2,2 mV to 22 mV · CMC 6,0·10⁻⁴ · U + 5,7 µV 100 kHz to 300 kHz — 22 mV to 220 mV · CMC 3,6·10⁻⁴ · U + 20 µV 100 kHz to 300 kHz — 0,22 V to 2,2 V · CMC 1,0·10⁻⁴ · U + 34 µV 100 kHz to 300 kHz — 2,2 V to 22 V · CMC 9,5·10⁻⁵ · U + 0,23 mV 100 kHz to 300 kHz — 22 V to 220 V · CMC 1,8·10⁻⁴ · U + 2,7 mV 300 kHz to 1 MHz — 2,2 mV to 22 mV · CMC 3,1·10⁻³ · U + 24 µV 300 kHz to 1 MHz — 22 mV to 220 mV · CMC 3,1·10⁻³ · U + 56 µV 300 kHz to 1 MHz — 0,22 V to 2,2 V · CMC 2,0·10⁻³ · U + 0,34 mV 300 kHz to 1 MHz — 2,2 V to 22 V · CMC 1,8·10⁻³ · U + 3,5 mV 50 Hz to 60 Hz — 1 kV to 10 kV · CMC 0,12 % AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/32 LMEEiO/35 LMEEiO/45 | |
| 7 | Sinusoidal measuring signal sources (generators, level generators) - unbalanced output: from 1 mV to 1000 V (0; 50; 75; 100; 135; 150; 600) Ω - balanced output: from 1 mV to 10 V (0; 100; 124; 135; 150; 600) Ω |
Calibration — AC voltage 20 Hz to 50 kHz — 1 mV · CMC 0,16% 20 Hz to 50 kHz — 1 mV to 30 mV · CMC 0,02% 20 Hz to 50 kHz — 0,030 V to 1000 V · CMC 0,03% 50 kHz to 100 kHz — 1 mV · CMC 0,25% 50 kHz to 100 kHz — 1 mV to 1000 V · CMC 0,05% AC voltage |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/10 | |
| 8 | Multimeters Digital voltmeters Analogue voltmeters Data acquisition cards Scopemeters Power network parameter meters Electrical safety testers Voltage dividers Measuring probes RF power meters Radio communication testers Electronic loads Line parameter and fault analysers |
Calibration — AC voltage 10 Hz to 40 Hz — 0,1 mV to 5 mV · CMC 3,5·10⁻⁴ · U + 3,5 µV 10 Hz to 40 Hz — 5 mV to 12 mV · CMC 1,5·10⁻⁴ · U + 4,7 µV 10 Hz to 40 Hz — 12 mV to 120 mV · CMC 8·10⁻⁵ · U + 4,7 µ 10 Hz to 40 Hz — 0,12 V to 1,2 V · CMC 8·10⁻⁵ · U + 47 µV 10 Hz to 40 Hz — 1,2 V to 12 V · CMC 8·10⁻⁵ · U + 0,47 m 10 Hz to 40 Hz — 12 V to 20 V · CMC 1,2·10⁻⁴ · U + 0,32 mV 10 Hz to 40 Hz — 20 V to 200V · CMC 1,2·10⁻⁴ · U + 2,5 mV 10 Hz to 40 Hz — 200 V to 1000 V · CMC 1,3·10⁻⁴ · U + 23 mV 20 Hz to 40 Hz — 0,22 V to 2,2 V · CMC 8·10⁻⁵ · U + 22 µV 40 Hz to 50 Hz — 200 V to 1000 V · CMC 1,1·10⁻⁴ · U + 23 mV 40 Hz to 1 kHz — 0,1 mV to 12 mV · CMC 2,4·10⁻⁴ · U + 1,3 µV 40 Hz to 1 kHz — 12 mV to 120 mV · CMC 8,2·10⁻⁵ · U + 2,3 µV 40 Hz to 20 kHz — 120 mV to 220 mV · CMC 6,7·10⁻⁵ · U + 8,1 µV 40 Hz to 20 kHz — 0,22 V to 2,2 V · CMC 4,2·10⁻⁵ · U + 12 µV 40 Hz to 20 kHz — 2,2 V to 22 V · CMC 5,0·10⁻⁵ · U + 60 µV 40 Hz to 20 kHz — 22 V to 220 V · CMC 6,0·10⁻⁵ · U + 0,8 mV 50 Hz to 1 kHz — 220 V to 1000 V · CMC 8,0·10⁻⁵ · U + 4,5 mV 1 kHz to 10 kHz — 220 V to 1000 V · CMC 1,1·10⁻⁴ · U + 23 mV 1 kHz to 20 kHz — 0,1 mV to 12 mV · CMC 3,5·10⁻⁴ · U + 1,3 µV 1 kHz to 20 kHz — 12 mV to 120 mV · CMC 1,2·10⁻⁴ · U + 4,6 µV 10 kHz to 33 kHz — 220 V to 1000 V · CMC 1,9·10⁻⁴ · U + 21 mV 20 kHz to 50 kHz — 0,1 mV to 2,2 mV · CMC 3,0·10⁻⁴ · U + 4,6 µV 20 kHz to 50 kHz — 2,2 mV to 22 mV · CMC 2,3·10⁻⁴ · U + 4,7 µV 20 kHz to 50 kHz — 22 mV to 220 mV · CMC 1,4·10⁻⁵ · U + 9 µV 20 kHz to 50 kHz — 0,22 V to 2,2 V · CMC 7,6·10⁻⁵ · U + 13 µV 20 kHz to 50 kHz — 2,2 V to 22 V · CMC 7,8·10⁻⁵ · U + 0,12 mV 20 kHz to 50 kHz — 22 V to 220 V · CMC 9,2·10⁻⁵ · U + 1,2 mV 33 kHz to 100 kHz — 220 V to 750 V · CMC 6,0·10⁻⁴ · U + 0,23 V 50 kHz to 100 kHz — 0,1 mV to 2,2 mV · CMC 5,0·10⁻⁴ · U + 6 µV 50 kHz to 100 kHz — 2,2 mV to 22 mV · CMC 6,0·10⁻⁴ · U + 5,7 µV 50 kHz to 100 kHz — 22 mV to 220 mV · CMC 3,6·10⁻⁴ · U + 20 µV 50 kHz to 100 kHz — 0,22 V to 2,2 V · CMC 1,0·10⁻⁴ · U + 34 µV 50 kHz to 100 kHz — 2,2 V to 22 V · CMC 9,5·10⁻⁵ · U + 0,23 mV 50 kHz to 100 kHz — 22 V to 220 V · CMC 1,8·10⁻⁴ · U + 2,7 mV 100 kHz to 300 kHz — 0,1 mV to 2,2 mV · CMC 5,0·10⁻⁴ · U + 6 µV 100 kHz to 300 kHz — 2,2 mV to 22 mV · CMC 6,0·10⁻⁴ · U + 5,7 µV 100 kHz to 300 kHz — 22 mV to 220 mV · CMC 3,6·10⁻⁴ · U + 20 µV 100 kHz to 300 kHz — 0,22 V to 2,2 V · CMC 1,0·10⁻⁴ · U + 34 µV 100 kHz to 300 kHz — 2,2 V to 22 V · CMC 9,5·10⁻⁵ · U + 0,23 mV 100 kHz to 300 kHz — 22 V to 220 V · CMC 1,8·10⁻⁴ · U + 2,7 mV 300 kHz to 1 MHz — 2,2 mV to 22 mV · CMC 3,1·10⁻³ · U + 24 µV 300 kHz to 1 MHz — 22 mV to 220 mV · CMC 3,1·10⁻³ · U + 56 µV 300 kHz to 1 MHz — 0,22 V to 2,2 V · CMC 2,0·10⁻³ · U + 0,34 mV 300 kHz to 1 MHz — 2,2 V to 22 V · CMC 1,8·10⁻³ · U + 3,5 mV AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/2 based on EURAMET cg-15 v. 3.0 LMEEiO/33 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53 | |
| 9 | Power quality analysers - THD U factor |
Calibration — AC voltage 50 Hz — 0% to 540 % · CMC 0,1 % AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/50 | |
| 10 | Power quality analysers - voltage harmonics |
Calibration — AC voltage 50 Hz; up to the 31st harmonic — 0 V to 400 V · CMC 0,1 % AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/50 | |
| 11 | Analogue voltmeters Digital voltmeters - unbalanced input: from 1 mV to 100 V (50; 75; 100; 135; 150; 600) Ω; high impedance - balanced input: from 1 mV to 10 V (100; 124; 135; 150; 600) Ω; high impedance |
Calibration — AC voltage 20 Hz to 30 Hz — 1 mV · CMC 0,72% 20 Hz to 30 Hz — 1 mV to 10 mV · CMC 0,10% 20 Hz to 30 Hz — 10 mV to 100 mV · CMC 0,04% 20 Hz to 30 Hz — 0,1 V to 10 V · CMC 0,02% 20 Hz to 30 Hz — 10 V to 100 V · CMC 0,03% 30 Hz to 30 kHz — 1 mV · CMC 0,72% 30 Hz to 30 kHz — 1 mV to 10 mV · CMC 0,10% 30 Hz to 30 kHz — 10 mV to 100 mV · CMC 0,07% 30 Hz to 30 kHz — 0,1 V to 10 V · CMC 0,02% 30 Hz to 30 kHz — 10 V to 100 V · CMC 0,03% 30 kHz to 100 kHz — 1 mV · CMC 0,81% 30 kHz to 100 kHz — 1 mV to 10 mV · CMC 0,18% 30 kHz to 100 kHz — 10 mV to 100 mV · CMC 0,15% 30 kHz to 100 kHz — 0,1 V to 100 V · CMC 0,04% AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/11 | |
| 12 | Oscilloscopes Data acquisition cards Scopemeters - frequency response flatness relative to the indication in the 50 kHz to 10 MHz band |
Calibration — AC voltage 50 kHz to 10 MHz — 4,44 mV to 5,56 V · CMC 1,8% 100 mHz to 100 MHz — 4,44 mV to 5,56 V · CMC 1,8% 100 MHz to 300 MHz — 4,44 mV to 5,56 V · CMC 2,4% 300 MHz to 550 MHz — 4,44 mV to 5,56 V · CMC 2,9% 550 MHz to 3 GHz — 4,44 mV to 2,224 V · CMC 4,1% 3 GHz to 6 GHz — 22,24 mV to 2,224 V · CMC 5,8% 6 GHz to 10 GHz — 22,24 mV to 2,224 V · CMC 5,5% 10 GHz to 12,4 GHz — 22,24 mV to 2,224 V · CMC 6,3% 12,4 GHz to 20 GHz — 22,24 mV to 2,224 V · CMC 8,6% AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/13 based on EURAMET cg-7 v. 1.0 | |
| 13 | Calibrators Data acquisition cards Leakage current simulators Power supplies Bridges Electrical safety testers Power network parameter meters |
Calibration — AC current 10 Hz to 40 Hz — 10 µA to 200 µA · CMC 2,0·10⁻⁴ · I + 15 nA 10 Hz to 40 Hz — 0,2 mA to 2 mA · CMC 2,0·10⁻⁴ · I + 0,1 µA 10 Hz to 40 Hz — 2 mA to 20 mA · CMC 2,0·10⁻⁴ · I + 1 µA 10 Hz to 40 Hz — 20 mA to 200 mA · CMC 2,0·10⁻⁴ · I + 10 µA 10 Hz to 45 Hz — 0,2 A to 1,2 A · CMC 2,0·10⁻⁴ · I + 0,14 mA 10 Hz to 45 Hz — 1,2 A to 3,1 A · CMC 2,5·10⁻⁴ · I + 0,9 mA 10 Hz to 45 Hz — 3,1 A to 12 A · CMC 3,5·10⁻⁴ · I + 1,1 mA 10 Hz to 45 Hz — 12 A to 30 A · CMC 6,0·10⁻⁴ · I + 20 mA 40 Hz to 1 kHz — 10 µA to 220 µA · CMC 1,2·10⁻⁴ · I + 10 nA 40 Hz to 1 kHz — 0,22 mA to 2,2 mA · CMC 1,2·10⁻⁴ · I + 40 nA 40 Hz to 1 kHz — 2,2 mA to 22 mA · CMC 1,2·10⁻⁴ · I + 0,4 µA 40 Hz to 1 kHz — 22 mA to 220 mA · CMC 1,2·10⁻⁴ · I + 3 µA 45 Hz to 1 kHz — 0,22 A to 1,2 A · CMC 2,0·10⁻⁴ · I + 0,07 mA 45 Hz to 1 kHz — 1,2 A to 3,1 A · CMC 2,0·10⁻⁴ · I + 0,5 mA 45 Hz to 1 kHz — 3,1 A to 12 A · CMC 3,0·10⁻⁴ · I + 0,8 mA 45 Hz to 1 kHz — 12 A to 30 A · CMC 4,0·10⁻⁴ · I + 15 mA 1 kHz to 5 kHz — 10 µA to 120 µA · CMC 2,0·10⁻⁴ · I + 13 nA 1 kHz to 5 kHz — 0,12 mA to 1,2 mA · CMC 2,0·10⁻⁴ · I + 0,1 µA 1 kHz to 5 kHz — 1,2 mA to 12 mA · CMC 2,0·10⁻⁴ · I + 1 µA 1 kHz to 5 kHz — 12 mA to 120 mA · CMC 2,2·10⁻⁴ · I + 9 µA 1 kHz to 5 kHz — 0,12 A to 1,2 A · CMC 2,2·10⁻⁴ · I + 0,1 mA 1 kHz to 5 kHz — 1,2 A to 3,1 A · CMC 2,2·10⁻⁴ · I + 0,7 mA 1 kHz to 5 kHz — 3,1 A to 12 A · CMC 3,3·10⁻⁴ · I + 1 mA 1 kHz to 5 kHz — 12 A to 30 A · CMC 4,0·10⁻³ · I + 20 mA 5 kHz to 10 kHz — 10 µA to 200 µA · CMC 5,4·10⁻⁴ · I + 25 nA 5 kHz to 10 kHz — 0,2 mA to 2 mA · CMC 3,2·10⁻⁴ · I + 0,25 µA 5 kHz to 10 kHz — 2 mA to 20 mA · CMC 3,2·10⁻⁴ · I + 2,5 µA 5 kHz to 10 kHz — 20 mA to 200 mA · CMC 3,0·10⁻⁴ · I + 22 µA 5 kHz to 10 kHz — 0,2 A to 2 A · CMC 8,0·10⁻⁴ · I + 0,25 mA 5 kHz to 10 kHz — 2 A to 3,1 A · CMC 2,2·10⁻³ · I + 0,7 mA 5 kHz to 10 kHz — 3,1 A to 12 A · CMC 2,2·10⁻³ · I + 1,2 mA 10 kHz to 20 kHz — 10 µA to 200 µA · CMC 7,5·10⁻⁴ · I + 25 nA 10 kHz to 20 kHz — 0,2 mA to 2 mA · CMC 7,5·10⁻⁴ · I + 0,25 µA 10 kHz to 20 kHz — 2 mA to 20 mA · CMC 7,5·10⁻⁴ · I + 2,5 µA 10 kHz to 20 kHz — 20 mA to 200 mA · CMC 7,0·10⁻⁴ · I + 23 µA 10 kHz to 20 kHz — 0,2 A to 2 A · CMC 3,3·10⁻³ · I + 0,6 mA 45 Hz to 400 Hz — 10 A to 100 A · CMC 0,065 % 45 Hz to 400 Hz — 100 A to 1000 A · CMC 0,2 % 400 Hz to 1 kHz — 10 A to 100 A · CMC 0,08 % 50 Hz to 60 Hz — 100 A to 500 A · CMC 0,05 % AC current |
Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) | LMEEiO/3 LMEEiO/5 LMEEiO/28 | |
| 14 | Multimeters Digital ammeters Analogue ammeters Data acquisition cards Clamp meters Electrical safety testers Power network parameter meters Electronic loads Measuring probes |
Calibration — AC current 10 Hz to 40 Hz — 10 µA to 200 µA · CMC 2,0·10⁻⁴ · I + 15 nA 10 Hz to 40 Hz — 0,2 mA to 2 mA · CMC 2,0·10⁻⁴ · I + 0,1 µA 10 Hz to 40 Hz — 2 mA to 20 mA · CMC 2,0·10⁻⁴ · I + 1 µA 10 Hz to 40 Hz — 20 mA to 200 mA · CMC 2,0·10⁻⁴ · I + 10 µA 10 Hz to 45 Hz — 0,2 A to 1,2 A · CMC 2,0·10⁻⁴ · I + 0,14 mA 10 Hz to 45 Hz — 1,2 A to 3,1 A · CMC 2,5·10⁻⁴ · I + 0,9 mA 10 Hz to 45 Hz — 3,1 A to 12 A · CMC 3,5·10⁻⁴ · I + 1,1 mA 10 Hz to 45 Hz — 12 A to 30 A · CMC 6,0·10⁻⁴ · I + 20 mA 40 Hz to 1 kHz — 10 µA to 220 µA · CMC 1,2·10⁻⁴ · I + 10 nA 40 Hz to 1 kHz — 0,22 mA to 2,2 mA · CMC 1,2·10⁻⁴ · I + 40 nA 40 Hz to 1 kHz — 2,2 mA to 22 mA · CMC 1,2·10⁻⁴ · I + 0,4 µA 40 Hz to 1 kHz — 22 mA to 220 mA · CMC 1,2·10⁻⁴ · I + 3 µA 45 Hz to 1 kHz — 0,22 A to 1,2 A · CMC 2,0·10⁻⁴ · I + 0,07 mA 45 Hz to 1 kHz — 1,2 A to 3,1 A · CMC 2,0·10⁻⁴ · I + 0,5 mA 45 Hz to 1 kHz — 3,1 A to 12 A · CMC 3,0·10⁻⁴ · I + 0,8 mA 45 Hz to 1 kHz — 12 A to 30 A · CMC 4,0·10⁻⁴ · I + 15 mA 1 kHz to 5 kHz — 10 µA to 120 µA · CMC 2,0·10⁻⁴ · I + 13 nA 1 kHz to 5 kHz — 0,12 mA to 1,2 mA · CMC 2,0·10⁻⁴ · I + 0,1 µA 1 kHz to 5 kHz — 1,2 mA to 12 mA · CMC 2,0·10⁻⁴ · I + 1 µA 1 kHz to 5 kHz — 12 mA to 120 mA · CMC 2,2·10⁻⁴ · I + 9 µA 1 kHz to 5 kHz — 0,12 A to 1,2 A · CMC 2,2·10⁻⁴ · I + 0,1 mA 1 kHz to 5 kHz — 1,2 A to 3,1 A · CMC 2,2·10⁻⁴ · I + 0,7 mA 1 kHz to 5 kHz — 3,1 A to 12 A · CMC 3,3·10⁻⁴ · I + 1 mA 1 kHz to 5 kHz — 12 A to 30 A · CMC 4,0·10⁻³ · I + 20 mA 5 kHz to 10 kHz — 10 µA to 200 µA · CMC 5,4·10⁻⁴ · I + 25 nA 5 kHz to 10 kHz — 0,2 mA to 2 mA · CMC 3,2·10⁻⁴ · I + 0,25 µA 5 kHz to 10 kHz — 2 mA to 20 mA · CMC 3,2·10⁻⁴ · I + 2,5 µA 5 kHz to 10 kHz — 20 mA to 200 mA · CMC 3,0·10⁻⁴ · I + 22 µA 5 kHz to 10 kHz — 0,2 A to 2 A · CMC 8,0·10⁻⁴ · I + 0,25 mA 5 kHz to 10 kHz — 2 A to 3,1 A · CMC 2,2·10⁻³ · I + 0,7 mA 5 kHz to 10 kHz — 3,1 A to 12 A · CMC 2,2·10⁻³ · I + 1,2 mA 10 kHz to 20 kHz — 10 µA to 200 µA · CMC 7,5·10⁻⁴ · I + 25 nA 10 kHz to 20 kHz — 0,2 mA to 2 mA · CMC 7,5·10⁻⁴ · I + 0,25 µA 10 kHz to 20 kHz — 2 mA to 20 mA · CMC 7,5·10⁻⁴ · I + 2,5 µA 10 kHz to 20 kHz — 20 mA to 200 mA · CMC 7,0·10⁻⁴ · I + 23 µA 10 kHz to 20 kHz — 0,2 A to 2 A · CMC 3,3·10⁻³ · I + 0,6 mA 45 Hz to 400 Hz — 10 A to 100 A · CMC 0,065 % 45 Hz to 400 Hz — 100 A to 1000 A · CMC 0,2 % 400 Hz to 1 kHz — 10 A to 100 A · CMC 0,08 % 50 Hz to 60 Hz — 100 A to 500 A · CMC 0,05 % AC current |
Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) | LMEEiO/2 based on EURAMET cg-15 v. 3.0 LMEEiO/5 LMEEiO/35 LMEEiO/45 LMEEiO/53 | |
| 15 | RCD testers | Calibration — AC current 50 Hz — 3 mA to 3000 mA · CMC 1 % AC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/35 | |
| 16 | Leakage current meters | Calibration — AC current 50 Hz — 15 µA to 4 mA · CMC 0,1 % 50 Hz — 4 mA to 1000 mA · CMC 0,03 % AC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/35 | |
| 17 | Power quality analysers - THD I factor |
Calibration — AC current 50 Hz — 0% to 540 % · CMC 0,1 % AC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/50 | |
| 18 | Power quality analysers - current harmonics |
Calibration — AC current 50 Hz; up to the 31st harmonic — 0 A to 20 A · CMC 0,1 % AC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/50 | |
| 19 | Power quality analysers - current under supply asymmetry conditions |
Calibration — AC current 50 Hz; 15% — 0 V to 400 V · CMC 0,05% AC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/50 | |
| 20 | Fixed resistors Variable resistors Calibrators Oscilloscopes Shunts Data acquisition cards |
Calibration — DC resistance 0 Ω to 0,0001 Ω · CMC 2,0·10⁻⁴ · R + 0,02 µΩ 0,0001 Ω · CMC 0,002 % 0,001 Ω · CMC 0,0005 % 0,001 Ω to 0,01 Ω · CMC 1,0·10⁻⁵ · R + 0,02 µΩ 0,01 Ω to 200 kΩ · CMC 0,0002 % 200 kΩ to 2 MΩ · CMC 1,0·10⁻⁵ · R + 1,2 Ω 1 MΩ · CMC 0,0004 % 2 MΩ to 20 MΩ · CMC 1,7·10⁻⁵ · R + 15 Ω 20 MΩ to 200 MΩ · CMC 7,0·10⁻⁵ · R + 1,2 kΩ 200 MΩ to 1 GΩ · CMC 1,7·10⁻⁴ · R + 120 kΩ 1 GΩ to 10 GΩ · CMC 0,04 % 10 GΩ to 100 GΩ · CMC 0,1 % 100 GΩ to 1 TΩ · CMC 0,4 % DC resistance |
Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) | LMEEiO/3 LMEEiO/4 LMEEiO/13 LMEEiO/45 | |
| 21 | Ohmmeters Multimeters Insulation resistance meters RLC meters Bridges Earth resistance meters Power network parameter meters Scopemeters Data acquisition cards Electronic loads Line parameter and fault analysers |
Calibration — DC resistance 0 Ω · CMC 0,05 µΩ 0,00001 Ω · CMC 0,02 % 0,0001 Ω · CMC 0,002 % 0,0001 Ω to 0,001 Ω · CMC 1,0·10⁻⁵ · R + 5 µΩ 0,001 Ω · CMC 0,0005% 0,001 Ω to 0,1 Ω · CMC 1,7·10⁻⁵ · R + 5 µΩ 0,01 Ω · CMC 0,0002 % 0,1 Ω · CMC 0,0002 % 0,1 Ω to 2 Ω · CMC 1,7·10⁻⁵ · R + 5 µΩ 1 Ω · CMC 0,0002 % 2 Ω to 20 Ω · CMC 1,1·10⁻⁵ · R + 15 µΩ 10 Ω · CMC 0,0002 % 20 Ω to 200 Ω · CMC 9,0·10⁻⁶ · R + 50 µΩ 25 Ω · CMC 0,0002 % 100 Ω · CMC 0,0002 % 200 Ω to 2 kΩ · CMC 9,0·10⁻⁶ · R + 0,5 mΩ 1 kΩ · CMC 0,0002 % 2 kΩ to 20 kΩ · CMC 9,0·10⁻⁶ · R + 0,005 Ω 10 kΩ · CMC 0,0002 % 20 kΩ to 200 kΩ · CMC 9,0·10⁻⁶ · R + 0,05 Ω 100 kΩ · CMC 0,0002 % 200 kΩ to 2 MΩ · CMC 1,0·10⁻⁵ · R + 1,2 Ω 1 MΩ · CMC 0,0004 % 2 MΩ to 20 MΩ · CMC 1,7·10⁻⁵ · R + 15 Ω 20 MΩ to 100 MΩ · CMC 7,0·10⁻⁵ · R + 1,2 kΩ 100 MΩ to 1 GΩ · CMC 1,7·10⁻⁴ · R + 120 kΩ 1 GΩ to 10 GΩ · CMC 0,04 % 10 GΩ to 100 GΩ · CMC 0,1 % 100 GΩ to 1 TΩ · CMC 0,4 % DC resistance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/2 based on EURAMET cg-15 v. 3.0 LMEEiO/5 LMEEiO/35 LMEEiO/42 | |
| 22 | Standard resistors Variable/decade resistors Resistance standards Shunts RLC bridges (meters) Impedance bridges (meters) Ohmmeters Electrical installation parameter meters (testers) Loop impedance meters Electronic loads |
Calibration — AC resistance f = 1 kHz — 0,001 Ω to 1 Ω · CMC 0,08 % f = 1 kHz — 1 Ω to 100 Ω · CMC 0,03 % f = 1 kHz — 100 Ω to 1 MΩ · CMC 0,02 % f = 1 kHz — 1 MΩ to 10 MΩ · CMC 0,12 % f = 40 Hz to 100 Hz — 0,01 Ω to 1 Ω · CMC 0,08 % f = 40 Hz to 100 Hz — 1 Ω to 10 Ω · CMC 0,07 % f = 40 Hz to 100 Hz — 10 Ω to 100 Ω · CMC 0,06 % f = 40 Hz to 100 Hz — 100 Ω to 10 kΩ · CMC 0,05 % f = 40 Hz to 100 Hz — 10 kΩ to 100 kΩ · CMC 0,06 % f = 40 Hz to 100 Hz — 100 kΩ to 1 MΩ · CMC 0,09 % f = 40 Hz to 100 Hz — 1 MΩ to 10 MΩ · CMC 0,45 % f = 100 Hz to 1 kHz — 0,01 Ω to 1 Ω · CMC 0,08 % f = 100 Hz to 1 kHz — 1 Ω to 10 Ω · CMC 0,05 % f = 100 Hz to 1 kHz — 10 Ω to 100 Ω · CMC 0,04 % f = 100 Hz to 1 kHz — 100 Ω to 10 kΩ · CMC 0,03 % f = 100 Hz to 1 kHz — 10 kΩ to 100 kΩ · CMC 0,04 % f = 100 Hz to 1 kHz — 100 kΩ to 1 MΩ · CMC 0,05 % f = 100 Hz to 1 kHz — 1 Ω to 10 MΩ · CMC 0,23 % f = 1 kHz to 3 kHz — 0,01 Ω to 1 Ω · CMC 0,13 % f = 1 kHz to 3 kHz — 1 Ω to 10 Ω · CMC 0,09 % f = 1 kHz to 3 kHz — 10 Ω to 100 Ω · CMC 0,04 % f = 1 kHz to 3 kHz — 100 Ω to 10 kΩ · CMC 0,03 % f = 1 kHz to 3 kHz — 10 kΩ to 100 kΩ · CMC 0,04 % f = 1 kHz to 3 kHz — 100 kΩ to 1 MΩ · CMC 0,05 % f = 1 kHz to 3 kHz — 1 MΩ to 10 MΩ · CMC 0,23 % f = 3 kHz to 6 kHz — 0,01 Ω to 1 Ω · CMC 0,23 % f = 3 kHz to 6 kHz — 1 Ω to 10 Ω · CMC 0,09 % f = 3 kHz to 6 kHz — 10 Ω to 100 Ω · CMC 0,04 % f = 3 kHz to 6 kHz — 100 Ω to 10 kΩ · CMC 0,03 % f = 3 kHz to 6 kHz — 10 kΩ to 100 kΩ · CMC 0,08 % f = 3 kHz to 6 kHz — 100 kΩ to 1 MΩ · CMC 0,13 % f = 3 kHz to 6 kHz — 1 MΩ to 10 MΩ · CMC 0,67 % f = 6 kHz to 10 kHz — 0,01 Ω to 1 Ω · CMC 0,23 % f = 6 kHz to 10 kHz — 1 Ω to 10 Ω · CMC 0,17 % f = 6 kHz to 10 kHz — 10 Ω to 100 Ω · CMC 0,07 % f = 6 kHz to 10 kHz — 100 Ω to 10 kΩ · CMC 0,05 % f = 6 kHz to 10 kHz — 10 kΩ to 100 kΩ · CMC 0,19 % f = 6 kHz to 10 kHz — 100 kΩ to 1 MΩ · CMC 0,33 % f = 10 kHz to 20 kHz — 1 Ω to 10 Ω · CMC 0,25 % f = 10 kHz to 20 kHz — 10 Ω to 100 Ω · CMC 0,09 % f = 10 kHz to 20 kHz — 100 Ω to 10 kΩ · CMC 0,07 % f = 10 kHz to 20 kHz — 10 kΩ to 100 kΩ · CMC 0,29 % f = 10 kHz to 20 kHz — 100 kΩ to 1 MΩ · CMC 0,53 % f = 20 kHz to 50 kHz — 1 Ω to 10 Ω · CMC 0,37 % f = 20 kHz to 50 kHz — 10 Ω to 100 Ω · CMC 0,13 % f = 20 kHz to 50 kHz — 100 Ω to 1 kΩ · CMC 0,10 % f = 20 kHz to 50 kHz — 1 kΩ to 10 kΩ · CMC 0,12 % f = 50 kHz to 100 kHz — 1 Ω to 10 Ω · CMC 0,77 % f = 50 kHz to 100 kHz — 10 Ω to 100 Ω · CMC 0,26 % f = 50 kHz to 100 kHz — 100 Ω to 1 kΩ · CMC 0,20 % f = 50 kHz to 100 kHz — 1 kΩ to 10 kΩ · CMC 0,23 % AC resistance |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/5 LMEEiO/14 LMEEiO/35 LMEEiO/53 | |
| 23 | Impedance standards | Calibration — Impedance f = 1 kHz — 1 Ω to 10 Ω · CMC 0,03 % f = 1 kHz — 10 Ω to 100 Ω · CMC 0,03 % f = 1 kHz — 100 Ω to 100 kΩ · CMC 0,02 % f = 1 kHz — 100 kΩ to 1 MΩ · CMC 0,02 % f = 1 kHz — 1 MΩ to 10 MΩ · CMC 0,12 % f = 1 kHz — φ · CMC 0,01 ° f = 40 Hz to 100 Hz — 0,1 Ω to 1 Ω · CMC 0,21 % f = 40 Hz to 100 Hz — 1 Ω to 10 Ω · CMC 0,07 % f = 40 Hz to 100 Hz — 10 Ω to 100 Ω · CMC 0,06 % f = 40 Hz to 100 Hz — 100 Ω to 10 kΩ · CMC 0,05 % f = 40 Hz to 100 Hz — 10 kΩ to 100 kΩ · CMC 0,06 % f = 40 Hz to 100 Hz — 100 kΩ to 1 MΩ · CMC 0,09 % f = 40 Hz to 100 Hz — 1 MΩ to 10 MΩ · CMC 0,45 % f = 40 Hz to 100 Hz — φ · CMC 0,04 ° f = 100 Hz to 250 Hz — 1 Ω to 10 Ω · CMC 0,06 % f = 100 Hz to 250 Hz — 10 Ω to 100 Ω · CMC 0,05 % f = 100 Hz to 250 Hz — 100 Ω to 10 kΩ · CMC 0,04 % f = 100 Hz to 250 Hz — 10 kΩ to 100 kΩ · CMC 0,05 % f = 100 Hz to 250 Hz — 100 kΩ to 1 MΩ · CMC 0,07 % f = 100 Hz to 250 Hz — 1 MΩ to 10 MΩ · CMC 0,34 % f = 100 Hz to 250 Hz — φ · CMC 0,03 ° f = 250 Hz to 1 kHz — 1 Ω to 10 Ω · CMC 0,05 % f = 250 Hz to 1 kHz — 10 Ω to 100 Ω · CMC 0,04 % f = 250 Hz to 1 kHz — 100 Ω to 10 kΩ · CMC 0,03 % f = 250 Hz to 1 kHz — 10 kΩ to 100 kΩ · CMC 0,04 % f = 250 Hz to 1 kHz — 100 kΩ to 1 MΩ · CMC 0,05 % f = 250 Hz to 1 kHz — 1 MΩ to 10 MΩ · CMC 0,23 % f = 250 Hz to 1 kHz — φ · CMC 0,02 ° f = 1 kHz to 3 kHz — 1 Ω to 10 Ω · CMC 0,09 % f = 1 kHz to 3 kHz — 10 Ω to 100 Ω · CMC 0,04 % f = 1 kHz to 3 kHz — 100 Ω to 10 kΩ · CMC 0,03 % f = 1 kHz to 3 kHz — 10 kΩ to 100 kΩ · CMC 0,08 % f = 1 kHz to 3 kHz — 100 kΩ to 1 MΩ · CMC 0,13 % f = 1 kHz to 3 kHz — 1 MΩ to 10 MΩ · CMC 0,67 % f = 1 kHz to 3 kHz — φ · CMC 0,02 ° f = 3 kHz to 6 kHz — 1 Ω to 10 Ω · CMC 0,09 % f = 3 kHz to 6 kHz — 10 Ω to 100 Ω · CMC 0,04 % f = 3 kHz to 6 kHz — 100 Ω to 10 kΩ · CMC 0,03 % f = 3 kHz to 6 kHz — 10 kΩ to 100 kΩ · CMC 0,04 % f = 3 kHz to 6 kHz — 100 kΩ to 1 MΩ · CMC 0,05 % f = 3 kHz to 6 kHz — 1 MΩ to 10 MΩ · CMC 0,23 % f = 3 kHz to 6 kHz — φ · CMC 0,02 ° f = 6 kHz to 10 kHz — 1 Ω to 10 Ω · CMC 0,17 % f = 6 kHz to 10 kHz — 10 Ω to 100 Ω · CMC 0,07 % f = 6 kHz to 10 kHz — 100 Ω to 10 kΩ · CMC 0,05 % f = 6 kHz to 10 kHz — 10 kΩ to 100 kΩ · CMC 0,19 % f = 6 kHz to 10 kHz — 100 kΩ to 1MΩ · CMC 0,33 % f = 6 kHz to 10 kHz — φ · CMC 0,04 ° f = 10 kHz to 20 kHz — 1 Ω to 10 Ω · CMC 0,25 % f = 10 kHz to 20 kHz — 10 Ω to 100 Ω · CMC 0,09 % f = 10 kHz to 20 kHz — 100 Ω to 10 kΩ · CMC 0,07 % f = 10 kHz to 20 kHz — 10 kΩ to 100 kΩ · CMC 0,29 % f = 10 kHz to 20 kHz — 100 kΩ to 1 MΩ · CMC 0,53 % f = 10 kHz to 20 kHz — φ · CMC 0,06 ° f = 20 kHz to 30 kHz — 1 Ω to 10 Ω · CMC 0,37 % f = 20 kHz to 30 kHz — 10 Ω to 100 Ω · CMC 0,13 % f = 20 kHz to 30 kHz — 100 Ω to 1 kΩ · CMC 0,10 % f = 20 kHz to 30 kHz — 1 kΩ to 10 kΩ · CMC 0,12 % f = 20 kHz to 30 kHz — φ · CMC 0,09 ° f = 50 kHz to 100 kHz — 1 Ω to 10 Ω · CMC 0,77 % f = 50 kHz to 100 kHz — 10 Ω to 100 Ω · CMC 0,26 % f = 50 kHz to 100 kHz — 100 Ω to 1 kΩ · CMC 0,20 % f = 50 kHz to 100 kHz — 1 kΩ to 10 kΩ · CMC 0,23 % f = 50 kHz to 100 kHz — φ · CMC 0,20 ° Impedance |
Internal procedure; Direct or indirect method; At permanent location (S) and outside of it (P) | LMEEiO/14 | |
| 24 | Impedance meters Bridges |
Calibration — Impedance f = 1 kHz — 90 Ω to 900 kΩ · CMC 0,02 % f = 1 kHz — φ · CMC 0,01 ° f = 100 kHz — 9 Ω to 9 kΩ · CMC 0,2 % f = 100 kHz — φ · CMC 0,2 ° Impedance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/5 | |
| 25 | Power network parameter meters | Calibration — Impedance f = 50 Hz — 0,1 Ω to 1 Ω · CMC 0,3 % f = 50 Hz — 1 Ω to 1 kΩ · CMC 0,05 % Impedance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/35 | |
| 26 | Self-inductance Fixed standard inductors Variable standard inductors Bridges Multimeters Inductance meters RLC meters |
Calibration — Inductance f = 1 kHz — 1 µH to 10 µH · CMC 0,06 µH f = 1 kHz — 10 µH to 50 µH · CMC 0,07 µH f = 1 kHz — 50 µH to 1 mH · CMC 0,06 % f = 1 kHz — 1 mH to 1 H · CMC 0,03 % f = 40 Hz to 55 Hz — 300 µH to 1 mH · CMC 0,6 % f = 40 Hz to 55 Hz — 1 mH to 90 mH · CMC 0,12 % f = 40 Hz to 55 Hz — 90 mH to 10 H · CMC 0,07 % f = 55 Hz to 6 kHz — 10 µH to 100 µH · CMC 0,07 % f = 55 Hz to 6 kHz — 100 µH to 1 H · CMC 0,04 % f = 55 Hz to 1 kHz — 1 H to 10 H · CMC 0,04% f = 6 kHz to 10 kHz — 10 µH to 100 µH · CMC 0,08 % f = 6 kHz to 10 kHz — 100 µH to 1 H · CMC 0,05 % f = 10 kHz to 20 kHz — 10 µH to 100 µH · CMC 0,09 % f = 10 kHz to 20 kHz — 100 µH to 100 mH · CMC 0,07 % f = 20 kHz to 50 kHz — 10 µH to 10 mH · CMC 0,1 % f = 50 kHz to 100 kHz — 10 µH to 10 mH · CMC 0,2 % Inductance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/14 LMEEiO/5 | |
| 27 | Fixed standard capacitors Variable standard capacitors Calibrators |
Calibration — Capacitance f = 1 kHz — 0,001 pF · CMC 0,00016 pF f = 1 kHz — 0,1 pF · CMC 0,01 % f = 1 kHz — 1 pF · CMC 0,01 % f = 1 kHz — 10 pF · CMC 0,003 % f = 1 kHz — 100 pF · CMC 0,003 % f = 1 kHz — 1000 pF · CMC 0,003 % f = 1 kHz — 1 µF to 10 µF · CMC 0,026 % f = 1 kHz — 10 µF to 100 µF · CMC 0,046 % f = 50 Hz to 1 kHz — 0,1 pF to 1 µF · CMC 0,012 % · C + 0,00003 pF f = 40 Hz to 100 Hz — 1 µF to 100 µF · CMC 0,06 % f = 100 Hz to 250 Hz — 1 µF to 100 µF · CMC 0,053 % f = 250 Hz to 1 kHz — 10 nF to 10 µF · CMC 0,04 % f = 250 Hz to 1 kHz — 10 µF to 100 µF · CMC 0,05 % f = 1 kHz to 6 kHz — 1 pF to 1 µF · CMC 0,02 % f = 1 kHz to 6 kHz — 1 µF to 10 µF · CMC 0,06 % f = 1 kHz to 6 kHz — 10 µF to 100 µF · CMC 0,3 % f = 6 kHz to 10 kHz — 1 pF µF to 1 µF · CMC 0,022 % f = 6 kHz to 10 kHz — 1 µF to 10 µF · CMC 0,15 % f = 6 kHz to 10 kHz — 10 µF to 100 µF · CMC 1 % f = 10 kHz to 20 kHz — 10 pF to 100 pF · CMC 0,14 % f = 10 kHz to 20 kHz — 0,1 nF to 100 nF · CMC 0,08 % f = 10 kHz to 20 kHz — 0,1 µF to 1 µF · CMC 0,11 % f = 10 kHz to 20 kHz — 1 µF to 10 µF · CMC 0,36 % f = 20 kHz to 50 kHz — 0,1 nF to 100 nF · CMC 0,12 % f = 20 kHz to 50 kHz — 0,1 µF to 1 µF · CMC 0,22 % f = 20 kHz to 50 kHz — 1 µF to 10 µF · CMC 1,2 % f = 50 kHz to 100 kHz — 0,1 nF to 10 nF · CMC 0,24 % f = 50 kHz to 100 kHz — 10 nF to 100 nF · CMC 0,28 % f = 50 kHz to 100 kHz — 0,1 µF to 1 µF · CMC 0,67 % Capacitance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/14 | |
| 28 | Bridges RLC meters Multimeters Capacitance meters |
Calibration — Capacitance f = 1 kHz — 0,1 pF · CMC 0,01 % f = 1 kHz — 1 pF · CMC 0,01 % f = 1 kHz — 10 pF · CMC 0,003 % f = 1 kHz — 100 pF · CMC 0,003 % f = 1 kHz — 1000 pF · CMC 0,003 % f = 1 kHz — 1 µF to 10 µF · CMC 0,026 % f = 1 kHz — 10 µF to 100 µF · CMC 0,046 % f = 50 Hz to 1 kHz — 0,1 pF to 1 µF · CMC 0,012 % · C + 0,00003 pF f = 40 Hz to 100 Hz — 1 µF to 100 µF · CMC 0,06 % f = 100 Hz to 250 Hz — 1 µF to 100 µF · CMC 0,053 % f = 250 Hz to 1 kHz — 10 nF to 10 µF · CMC 0,04 % f = 250 Hz to 1 kHz — 10 µF to 100 µF · CMC 0,05 % f = 1 kHz to 6 kHz — 1 pF to 1 µF · CMC 0,02 % f = 1 kHz to 6 kHz — 1 µF to 10 µF · CMC 0,06 % f = 1 kHz to 6 kHz — 10 µF to 100 µF · CMC 0,3 % f = 6 kHz to 10 kHz — 1 pF to 1 µF · CMC 0,022 % f = 6 kHz to 10 kHz — 1 µF to 10 µF · CMC 0,15 % f = 6 kHz to 10 kHz — 10 µF to 100 µF · CMC 1 % f = 10 kHz to 20 kHz — 10 pF to 100 pF · CMC 0,14 % f = 10 kHz to 20 kHz — 0,1 nF to 100 nF · CMC 0,08 % f = 10 kHz to 20 kHz — 0,1 µF to 1 µF · CMC 0,11 % f = 10 kHz to 20 kHz — 1 µF to 10 µF · CMC 0,36 % f = 20 kHz to 50 kHz — 0,1 nF to 100 nF · CMC 0,12 % f = 20 kHz to 50 kHz — 0,1 µF to 1 µF · CMC 0,22 % f = 20 kHz to 50 kHz — 1 µF to 10 µF · CMC 1,2 % f = 50 kHz to 100 kHz — 0,1 nF to 10 nF · CMC 0,24 % f = 50 kHz to 100 kHz — 10 nF to 100 nF · CMC 0,28 % f = 50 kHz to 100 kHz — 0,1 µF to 1 µF · CMC 0,67 % Capacitance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/5 LMEEiO/2 based on EURAMET cg-15 v. 3.0 | |
| 29 | Multimeters | Calibration — Capacitance 11 µF to 11 mF · CMC 0,55 % 11 mF to 33 mF · CMC 0,85 % 33 mF to 110 mF · CMC 1,2 % Capacitance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/5 LMEEiO/2 based on EURAMET cg-15 v. 3.0 | |
| 30 | Line parameter and fault analysers | Calibration — Capacitance 50 nF to 9 µF · CMC 0,1 % Capacitance |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/42 | |
| 31 | Oscilloscopes Scopemeters Data acquisition cards Measuring probes |
Calibration — Capacitance 1 pF to 35 pF · CMC 2 % + 0,25 pF 35 pF to 120 pF · CMC 2,5 % + 0,25 pF Capacitance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/13 based on EURAMET cg-7 v. 1.0 | |
| 32 | Power meters Analysers |
Calibration — Phase angle f = 50 Hz to 60 Hz; 0,1 A to 20 A; 1 V to 600 V — -90° to 90° · CMC 0,02° f = 50 Hz to 60 Hz; 0,1 A to 20 A; 1 V to 600 V; power factor cosφ — -1,0 to -0,5 and 0,5 to 1,0 · CMC 0,04 % f = 50 Hz to 60 Hz; 0,1 A to 20 A; 1 V to 600 V; power factor cosφ — -0,5 to 0,5 · CMC 0,2 % Phase angle |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/46 | |
| 33 | AC active energy meters Power analysers Power meters Power quality analysers |
Calibration — Energy f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 to 20 A — |cosφ| = 1 to 0,5 · CMC 0,04 % f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 to 20 A — |cosφ| = 0,5 to 0,1 · CMC 0,1 % Energy |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/46 | |
| 34 | DC power meters Electronic loads |
Calibration — DC power 5 mW to 10 kW · CMC 0,05 % DC power |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/46 LMEEiO/53 | |
| 35 | AC active power meters Wattmeters |
Calibration — AC power f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 3 W to 12 kW — |cosφ| = 1 to 0,5 · CMC 0,04 % f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 3 W to 12 kW — |cosφ| = 0,5 to 0,1 · CMC 0,1 % f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A — |cosφ| = 1 to 0,9 · CMC 0,05 % f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A — |cosφ| = 0,9 to 0,1 · CMC 0,2 % AC power |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/46 LMEEiO/53 | |
| 36 | AC reactive power meters Varmeters |
Calibration — AC power f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 3 var to 12 kvar — |sinφ| = 1 to 0,5 · CMC 0,04 % f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 3 var to 12 kvar — |sinφ| = 0,5 to 0,1 · CMC 0,1 % f = 50 Hz to 60 Hz; 1 V to 560 V,; 5 mA to 0,1 A i 20 A to 100 A — |sinφ| = 1 to 0,9 · CMC 0,05 % f = 50 Hz to 60 Hz; 1 V to 560 V,; 5 mA to 0,1 A i 20 A to 100 A — |sinφ| = 0,9 to 0,1 · CMC 0,2 % AC power |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/46 LMEEiO/53 | |
| 37 | AC apparent power meters | Calibration — AC power f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A — 3 VA to 12 kVA · CMC 0,04 % f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A — |cosφ| = 1 to 0,9 · CMC 0,05 % f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A — |cosφ| = 0,9 to 0,1 · CMC 0,2 % AC power |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/46 LMEEiO/53 | |
| 38 | Three-phase AC active power meters | Calibration — AC power f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 9 W to 36 kW — |cosφ| = 1 to 0,5 · CMC 0,04 % f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 9 W to 36 kW — |cosφ| = 0,5 to 0,1 · CMC 0,1 % f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A — |cosφ| = 1 to 0,9 · CMC 0,05 % f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A — |cosφ| = 0,9 to 0,1 · CMC 0,2 % AC power |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/46 LMEEiO/53 | |
| 39 | Three-phase AC reactive power meters | Calibration — AC power f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 9 var to 36 kvar — |cosφ| = 1 to 0,5 · CMC 0,04 % f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 9 var to 36 kvar — |cosφ| = 0,5 to 0,1 · CMC 0,1 % f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A — |cosφ| = 1 to 0,9 · CMC 0,05 % f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A — |cosφ| = 0,9 to 0,1 · CMC 0,2 % AC power |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/46 LMEEiO/53 | |
| 40 | Three-phase AC apparent power meters | Calibration — AC power f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A — 9 VA to 36 kVA · CMC 0,04 % f = 50 Hz to 60 Hz; 1 V to 560 V,; 5 mA to 0,1 A i 20 A to 100 A — |cosφ| = 1 to 0,9 · CMC 0,05 % f = 50 Hz to 60 Hz; 1 V to 560 V,; 5 mA to 0,1 A i 20 A to 100 A — |cosφ| = 0,9 to 0,1 · CMC 0,2 % AC power |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/46 LMEEiO/53 | |
| 41 | Temperature indicators (meters) (including controllers) Temperature simulators |
Calibration — Electrical simulation of quantities Simulation of a resistance sensor — -200 °C to 850 °C · CMC 0,005 °C Simulation of a thermocouple — -270 °C to 1820 °C · CMC 0,03 °C Electrical simulation of quantities |
Internal procedure; Indirect method; At permanent location (S) and outside of it (P) | LMEEiO/2 LMEEiO/3 | |
| 42 | Generators Network analysers Spectrum analysers Radio communication testers Measuring receivers Amplifiers - output power level |
Calibration — RF electrical quantities f = 10 Hz to 9 kHz — -40 dBm to -30 dBm · CMC 0,20 dB f = 10 Hz to 9 kHz — -30 dBm to -20 dBm · CMC 0,068 dB f = 10 Hz to 9 kHz — -20 dBm to -10 dBm · CMC 0,029 dB f = 10 Hz to 9 kHz — -10 dBm to 0 dBm · CMC 0,019 dB f = 10 Hz to 9 kHz — 0 dBm to 30 dBm · CMC 0,024 dB f = 9 kHz to 20 kHz — -40 dBm to -30 dBm · CMC 0,14 dB f = 9 kHz to 20 kHz — -30 dBm to -20 dBm · CMC 0,057 dB f = 9 kHz to 20 kHz — -20 dBm to -10 dBm · CMC 0,029 dB f = 9 kHz to 20 kHz — -10 dBm to 0 dBm · CMC 0,019 dB f = 9 kHz to 20 kHz — 0 dBm to 30 dBm · CMC 0,024 dB f = 20 kHz to 50 kHz — -40 dBm to -30 dBm · CMC 0,14 dB f = 20 kHz to 50 kHz — -30 dBm to -20 dBm · CMC 0,057 dB f = 20 kHz to 50 kHz — -20 dBm to -10 dBm · CMC 0,034 dB f = 20 kHz to 50 kHz — -10 dBm to 0 dBm · CMC 0,023 dB f = 20 kHz to 50 kHz — 0 dBm to 30 dBm · CMC 0,033 dB f = 50 kHz to 100 kHz — -40 dBm to -30 dBm · CMC 0,14 dB f = 50 kHz to 100 kHz — -30 dBm to -20 dBm · CMC 0,057 dB f = 50 kHz to 100 kHz — -20 dBm to -10 dBm · CMC 0,041 dB f = 50 kHz to 100 kHz — -10 dBm to 0 dBm · CMC 0,028 dB f = 50 kHz to 100 kHz — 0 dBm to 30 dBm · CMC 0,052 dB f = 100 kHz to 10 MHz — -130 dBm to -120 dBm · CMC 1,2 dB f = 100 kHz to 10 MHz — -120 dBm to -110 dBm · CMC 0,57 dB f = 100 kHz to 10 MHz — -110 dBm to -100 dBm · CMC 0,23 dB f = 100 kHz to 10 MHz — -100 dBm to -90 dBm · CMC 0,11 dB f = 100 kHz to 10 MHz — -90 dBm to -80 dBm · CMC 0,10 dB f = 100 kHz to 10 MHz — -80 dBm to -70 dBm · CMC 0,097 dB f = 100 kHz to 10 MHz — -70 dBm to -60 dBm · CMC 0,093 dB f = 100 kHz to 10 MHz — -60 dBm to -50 dBm · CMC 0,067 dB f = 100 kHz to 10 MHz — -50 dBm to -40 dBm · CMC 0,065 dB f = 100 kHz to 10 MHz — -40 dBm to -30 dBm · CMC 0,062 dB f = 100 kHz to 10 MHz — -30 dBm to -20 dBm · CMC 0,057 dB f = 100 kHz to 10 MHz — -20 dBm to -10 dBm · CMC 0,055 dB f = 100 kHz to 10 MHz — -10 dBm to 0 dBm · CMC 0,055 dB f = 100 kHz to 10 MHz — 0 dBm to 20 dBm · CMC 0,055 dB f = 100 kHz to 10 MHz — 20 dBm to 30 dBm · CMC 0,060 dB f = 100 kHz to 10 MHz — 30 dBm to 45 dBm · CMC 0,18 dB f = 100 kHz to 10 MHz — 45 dBm to 52 dBm · CMC 0,21 dB f = 10 MHz to 3,05 GHz — -130 dBm to -120 dBm · CMC 0,94 dB f = 10 MHz to 3,05 GHz — -120 dBm to -110 dBm · CMC 0,44 dB f = 10 MHz to 3,05 GHz — -110 dBm to -100 dBm · CMC 0,18 dB f = 10 MHz to 3,05 GHz — -100 dBm to -90 dBm · CMC 0,11 dB f = 10 MHz to 3,05 GHz — -90 dBm to -80 dBm · CMC 0,10 dB f = 10 MHz to 3,05 GHz — -80 dBm to -70 dBm · CMC 0,099 dB f = 10 MHz to 3,05 GHz — -70 dBm to -60 dBm · CMC 0,095 dB f = 10 MHz to 3,05 GHz — -60 dBm to -50 dBm · CMC 0,071 dB f = 10 MHz to 3,05 GHz — -50 dBm to -40 dBm · CMC 0,068 dB f = 10 MHz to 3,05 GHz — -40 dBm to -30 dBm · CMC 0,066 dB f = 10 MHz to 3,05 GHz — -30 dBm to -20 dBm · CMC 0,060 dB f = 10 MHz to 3,05 GHz — -20 dBm to -10 dBm · CMC 0,059 dB f = 10 MHz to 3,05 GHz — -10 dBm to 0 dBm · CMC 0,059 dB f = 10 MHz to 3,05 GHz — 0 dBm to 20 dBm · CMC 0,059 dB f = 10 MHz to 3,05 GHz — 20 dBm to 35 dBm · CMC 0,060 dB f = 10 MHz to 3,05 GHz — 35 dBm to 45 dBm · CMC 0,18 dB f = 10 MHz to 3,05 GHz — 45 dBm to 52 dBm · CMC 0,21 dB f = 3,05 GHz to 6,6 GHz — -120 dBm to -110 dBm · CMC 0,82 dB f = 3,05 GHz to 6,6 GHz — -110 dBm to -100 dBm · CMC 0,37 dB f = 3,05 GHz to 6,6 GHz — -100 dBm to -90 dBm · CMC 0,16 dB f = 3,05 GHz to 6,6 GHz — -90 dBm to -80 dBm · CMC 0,10 dB f = 3,05 GHz to 6,6 GHz — -80 dBm to -70 dBm · CMC 0,097 dB f = 3,05 GHz to 6,6 GHz — -70 dBm to -60 dBm · CMC 0,093 dB f = 3,05 GHz to 6,6 GHz — -60 dBm to -50 dBm · CMC 0,089 dB f = 3,05 GHz to 6,6 GHz — -50 dBm to -40 dBm · CMC 0,065 dB f = 3,05 GHz to 6,6 GHz — -40 dBm to -30 dBm · CMC 0,062 dB f = 3,05 GHz to 6,6 GHz — -30 dBm to -20 dBm · CMC 0,057 dB f = 3,05 GHz to 6,6 GHz — -20 dBm to -10 dBm · CMC 0,055 dB f = 3,05 GHz to 6,6 GHz — -10 dBm to 0 dBm · CMC 0,055 dB f = 3,05 GHz to 6,6 GHz — 0 dBm to 20 dBm · CMC 0,055 dB f = 3,05 GHz to 6,6 GHz — 20 dBm to 35 dBm · CMC 0,058 dB f = 3,05 GHz to 6,6 GHz — 35 dBm to 44 dBm · CMC 0,18 dB f = 6,6 GHz to 13,2 GHz — -110 dBm to -100 dBm · CMC 0,76 dB f = 6,6 GHz to 13,2 GHz — -100 dBm to -90 dBm · CMC 0,33 dB f = 6,6 GHz to 13,2 GHz — -90 dBm to -80 dBm · CMC 0,14 dB f = 6,6 GHz to 13,2 GHz — -80 dBm to -70 dBm · CMC 0,097 dB f = 6,6 GHz to 13,2 GHz — -70 dBm to -60 dBm · CMC 0,093 dB f = 6,6 GHz to 13,2 GHz — -60 dBm to -50 dBm · CMC 0,089 dB f = 6,6 GHz to 13,2 GHz — -50 dBm to -40 dBm · CMC 0,065 dB f = 6,6 GHz to 13,2 GHz — -40 dBm to -30 dBm · CMC 0,062 dB f = 6,6 GHz to 13,2 GHz — -30 dBm to -20 dBm · CMC 0,057 dB f = 6,6 GHz to 13,2 GHz — -20 dBm to -10 dBm · CMC 0,055 dB f = 6,6 GHz to 13,2 GHz — -10 dBm to 0 dBm · CMC 0,055 dB f = 6,6 GHz to 13,2 GHz — 0 dBm to 20 dBm · CMC 0,055 dB f = 6,6 GHz to 13,2 GHz — 20 dBm to 30 dBm · CMC 0,060 dB f = 6,6 GHz to 13,2 GHz — 30 dBm to 35 dBm · CMC 0,083 dB f = 6,6 GHz to 13,2 GHz — 35 dBm to 44 dBm · CMC 0,19 dB f = 13,2 GHz to 18 GHz — -100 dBm to -90 dBm · CMC 0,65 dB f = 13,2 GHz to 18 GHz — -90 dBm to -80 dBm · CMC 0,27 dB f = 13,2 GHz to 18 GHz — -80 dBm to -70 dBm · CMC 0,13 dB f = 13,2 GHz to 18 GHz — -70 dBm to -60 dBm · CMC 0,093 dB f = 13,2 GHz to 18 GHz — -60 dBm to -50 dBm · CMC 0,089 dB f = 13,2 GHz to 18 GHz — -50 dBm to -40 dBm · CMC 0,085 dB f = 13,2 GHz to 18 GHz — -40 dBm to -30 dBm · CMC 0,062 dB f = 13,2 GHz to 18 GHz — -30 dBm to -20 dBm · CMC 0,057 dB f = 13,2 GHz to 18 GHz — -20 dBm to -10 dBm · CMC 0,055 dB f = 13,2 GHz to 18 GHz — -10 dBm to 0 dBm · CMC 0,055 dB f = 13,2 GHz to 18 GHz — 0 dBm to 20 dBm · CMC 0,055 dB f = 13,2 GHz to 18 GHz — 20 dBm to 30 dBm · CMC 0,060 dB f = 13,2 GHz to 18 GHz — 30 dBm to 35 dBm · CMC 0,13 dB f = 13,2 GHz to 18 GHz — 35 dBm to 44 dBm · CMC 0,22 dB f = 18 GHz to 19,2 GHz — -100 dBm to -90 dBm · CMC 0,65 dB f = 18 GHz to 19,2 GHz — -90 dBm to -80 dBm · CMC 0,28 dB f = 18 GHz to 19,2 GHz — -80 dBm to -70 dBm · CMC 0,14 dB f = 18 GHz to 19,2 GHz — -70 dBm to -60 dBm · CMC 0,10 dB f = 18 GHz to 19,2 GHz — -60 dBm to -50 dBm · CMC 0,10 dB f = 18 GHz to 19,2 GHz — -50 dBm to -40 dBm · CMC 0,098 dB f = 18 GHz to 19,2 GHz — -40 dBm to -30 dBm · CMC 0,079 dB f = 18 GHz to 19,2 GHz — -30 dBm to -20 dBm · CMC 0,077 dB f = 18 GHz to 19,2 GHz — -20 dBm to -10 dBm · CMC 0,075 dB f = 18 GHz to 19,2 GHz — -10 dBm to 0 dBm · CMC 0,073 dB f = 18 GHz to 19,2 GHz — 0 dBm to 20 dBm · CMC 0,073 dB f = 18 GHz to 19,2 GHz — 20 dBm to 30 dBm · CMC 0,077 dB f = 19,2 GHz to 26,5 GHz — -100 dBm to -90 dBm · CMC 1,1 dB f = 19,2 GHz to 26,5 GHz — -90 dBm to -80 dBm · CMC 0,52 dB f = 19,2 GHz to 26,5 GHz — -80 dBm to -70 dBm · CMC 0,22 dB f = 19,2 GHz to 26,5 GHz — -70 dBm to -60 dBm · CMC 0,12 dB f = 19,2 GHz to 26,5 GHz — -60 dBm to -50 dBm · CMC 0,12 dB f = 19,2 GHz to 26,5 GHz — -50 dBm to -40 dBm · CMC 0,12 dB f = 19,2 GHz to 26,5 GHz — -40 dBm to -30 dBm · CMC 0,11 dB f = 19,2 GHz to 26,5 GHz — -30 dBm to -20 dBm · CMC 0,098 dB f = 19,2 GHz to 26,5 GHz — -20 dBm to -10 dBm · CMC 0,097 dB f = 19,2 GHz to 26,5 GHz — -10 dBm to 0 dBm · CMC 0,095 dB f = 19,2 GHz to 26,5 GHz — 0 dBm to 20 dBm · CMC 0,095 dB f = 19,2 GHz to 26,5 GHz — 20 dBm to 30 dBm · CMC 0,098 dB f = 26,5 GHz to 40 GHz — -80 dBm to -70 dBm · CMC 0,37 dB f = 26,5 GHz to 40 GHz — -70 dBm to -60 dBm · CMC 0,18 dB f = 26,5 GHz to 40 GHz — -60 dBm to -50 dBm · CMC 0,14 dB f = 26,5 GHz to 40 GHz — -50 dBm to -40 dBm · CMC 0,14 dB f = 26,5 GHz to 40 GHz — -40 dBm to -30 dBm · CMC 0,12 dB f = 26,5 GHz to 40 GHz — -30 dBm to -20 dBm · CMC 0,12 dB f = 26,5 GHz to 40 GHz — -20 dBm to -10 dBm · CMC 0,12 dB f = 26,5 GHz to 40 GHz — -10 dBm to 0 dBm · CMC 0,12 dB f = 26,5 GHz to 40 GHz — 0 dBm to 20 dBm · CMC 0,12 dB f = 26,5 GHz to 40 GHz — 20 dBm to 30 dBm · CMC 0,12 dB f = 40 GHz to 50 GHz — -40 dBm to -30 dBm · CMC 0,19 dB f = 40 GHz to 50 GHz — -30 dBm to -20 dBm · CMC 0,19 dB f = 40 GHz to 50 GHz — -20 dBm to -10 dBm · CMC 0,15 dB f = 40 GHz to 50 GHz — -10 dBm to 0 dBm · CMC 0,14 dB f = 40 GHz to 50 GHz — 0 dBm to 20 dBm · CMC 0,14 dB RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/32 LMEEiO/39 LMEEiO/40 LMEEiO/48 | |
| 43 | Power meters - power level at the reference output |
Calibration — RF electrical quantities f = 50 MHz — 1 mW · CMC 0,0049 mW f = 50 MHz — 0 dBm · CMC 0,022 dB RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/33 | |
| 44 | Power meters Power sensors Network analysers Spectrum analysers Antenna and cable system analysers Analogue modulation analysers Radio communication testers Measuring receivers - measured power level |
Calibration — RF electrical quantities f = 50 MHz — -10 dBm to 10 dBm · CMC 0,076 dB f = 10 Hz to 9 kHz — -40 dBm to -30 dBm · CMC 0,21 dB f = 10 Hz to 9 kHz — -30 dBm to -20 dBm · CMC 0,097 dB f = 10 Hz to 9 kHz — -20 dBm to -10 dBm · CMC 0,075 dB f = 10 Hz to 9 kHz — -10 dBm to 0 dBm · CMC 0,072 dB f = 10 Hz to 9 kHz — 0 dBm to 20 dBm · CMC 0,073 dB f = 9 kHz to 100 kHz — -40 dBm to -30 dBm · CMC 0,16 dB f = 9 kHz to 100 kHz — -30 dBm to -20 dBm · CMC 0,090 dB f = 9 kHz to 100 kHz — -20 dBm to -10 dBm · CMC 0,081 dB f = 9 kHz to 100 kHz — -10 dBm to 0 dBm · CMC 0,075 dB f = 9 kHz to 100 kHz — 0 dBm to 20 dBm · CMC 0,087 dB f = 100 kHz to 10 MHz — -130 dBm to -120 dBm · CMC 1,20 dB f = 100 kHz to 10 MHz — -120 dBm to -110 dBm · CMC 0,57 dB f = 100 kHz to 10 MHz — -110 dBm to -100 dBm · CMC 0,24 dB f = 100 kHz to 10 MHz — -100 dBm to -90 dBm · CMC 0,13 dB f = 100 kHz to 10 MHz — -90 dBm to -80 dBm · CMC 0,12 dB f = 100 kHz to 10 MHz — -80 dBm to -70 dBm · CMC 0,12 dB f = 100 kHz to 10 MHz — -70 dBm to -60 dBm · CMC 0,12 dB f = 100 kHz to 10 MHz — -60 dBm to -50 dBm · CMC 0,096 dB f = 100 kHz to 10 MHz — -50 dBm to -40 dBm · CMC 0,095 dB f = 100 kHz to 10 MHz — -40 dBm to -30 dBm · CMC 0,093 dB f = 100 kHz to 10 MHz — -30 dBm to -20 dBm · CMC 0,090 dB f = 100 kHz to 10 MHz — -20 dBm to -10 dBm · CMC 0,088 dB f = 100 kHz to 10 MHz — -10 dBm to 0 dBm · CMC 0,088 dB f = 100 kHz to 10 MHz — 0 dBm to 20 dBm · CMC 0,088 dB f = 100 kHz to 10 MHz — 20 dBm to 30 dBm · CMC 0,092 dB f = 100 kHz to 10 MHz — 30 dBm to 45 dBm · CMC 0,19 dB f = 100 kHz to 10 MHz — 45 dBm to 52 dBm · CMC 0,22 dB f = 10 MHz to 500 MHz — -130 dBm to -120 dBm · CMC 0,94 dB f = 10 MHz to 500 MHz — -120 dBm to -110 dBm · CMC 0,45 dB f = 10 MHz to 500 MHz — -110 dBm to -100 dBm · CMC 0,19 dB f = 10 MHz to 500 MHz — -100 dBm to -90 dBm · CMC 0,13 dB f = 10 MHz to 500 MHz — -90 dBm to -80 dBm · CMC 0,12 dB f = 10 MHz to 500 MHz — -80 dBm to -70 dBm · CMC 0,12 dB f = 10 MHz to 500 MHz — -70 dBm to -60 dBm · CMC 0,12 dB f = 10 MHz to 500 MHz — -60 dBm to -50 dBm · CMC 0,099 dB f = 10 MHz to 500 MHz — -50 dBm to -40 dBm · CMC 0,097 dB f = 10 MHz to 500 MHz — -40 dBm to -30 dBm · CMC 0,096 dB f = 10 MHz to 500 MHz — -30 dBm to -20 dBm · CMC 0,092 dB f = 10 MHz to 500 MHz — -20 dBm to -10 dBm · CMC 0,091 dB f = 10 MHz to 500 MHz — -10 dBm to 0 dBm · CMC 0,086 dB f = 10 MHz to 500 MHz — 0 dBm to 20 dBm · CMC 0,086 dB f = 10 MHz to 500 MHz — 20 dBm to 35 dBm · CMC 0,092 dB f = 10 MHz to 500 MHz — 35 dBm to 45 dBm · CMC 0,19 dB f = 10 MHz to 500 MHz — 45 dBm to 52 dBm · CMC 0,22 dB f = 500 MHz to 3,05 GHz — -130 dBm to -120 dBm · CMC 0,94 dB f = 500 MHz to 3,05 GHz — -120 dBm to -110 dBm · CMC 0,45 dB f = 500 MHz to 3,05 GHz — -110 dBm to -100 dBm · CMC 0,19 dB f = 500 MHz to 3,05 GHz — -100 dBm to -90 dBm · CMC 0,13 dB f = 500 MHz to 3,05 GHz — -90 dBm to -80 dBm · CMC 0,12 dB f = 500 MHz to 3,05 GHz — -80 dBm to -70 dBm · CMC 0,12 dB f = 500 MHz to 3,05 GHz — -70 dBm to -60 dBm · CMC 0,12 dB f = 500 MHz to 3,05 GHz — -60 dBm to -50 dBm · CMC 0,099 dB f = 500 MHz to 3,05 GHz — -50 dBm to -40 dBm · CMC 0,097 dB f = 500 MHz to 3,05 GHz — -40 dBm to -30 dBm · CMC 0,096 dB f = 500 MHz to 3,05 GHz — -30 dBm to -20 dBm · CMC 0,092 dB f = 500 MHz to 3,05 GHz — -20 dBm to -10 dBm · CMC 0,091 dB f = 500 MHz to 3,05 GHz — -10 dBm to 0 dBm · CMC 0,091 dB f = 500 MHz to 3,05 GHz — 0 dBm to 20 dBm · CMC 0,091 dB f = 500 MHz to 3,05 GHz — 20 dBm to 35 dBm · CMC 0,092 dB f = 500 MHz to 3,05 GHz — 35 dBm to 44 dBm · CMC 0,19 dB f = 3,05 GHz to 4 GHz — -120 dBm to -110 dBm · CMC 0,82 dB f = 3,05 GHz to 4 GHz — -110 dBm to -100 dBm · CMC 0,38 dB f = 3,05 GHz to 4 GHz — -100 dBm to -90 dBm · CMC 0,17 dB f = 3,05 GHz to 4 GHz — -90 dBm to -80 dBm · CMC 0,12 dB f = 3,05 GHz to 4 GHz — -80 dBm to -70 dBm · CMC 0,12 dB f = 3,05 GHz to 4 GHz — -70 dBm to -60 dBm · CMC 0,12 dB f = 3,05 GHz to 4 GHz — -60 dBm to -50 dBm · CMC 0,11 dB f = 3,05 GHz to 4 GHz — -50 dBm to -40 dBm · CMC 0,095 dB f = 3,05 GHz to 4 GHz — -40 dBm to -30 dBm · CMC 0,093 dB f = 3,05 GHz to 4 GHz — -30 dBm to -20 dBm · CMC 0,090 dB f = 3,05 GHz to 4 GHz — -20 dBm to -10 dBm · CMC 0,088 dB f = 3,05 GHz to 4 GHz — -10 dBm to 0 dBm · CMC 0,088 dB f = 3,05 GHz to 4 GHz — 0 dBm to 20 dBm · CMC 0,088 dB f = 3,05 GHz to 4 GHz — 20 dBm to 35 dBm · CMC 0,090 dB f = 3,05 GHz to 4 GHz — 35 dBm to 40 dBm · CMC 0,19 dB f = 4 GHz to 6,6 GHz — -120 dBm to -110 dBm · CMC 0,82 dB f = 4 GHz to 6,6 GHz — -110 dBm to -100 dBm · CMC 0,38 dB f = 4 GHz to 6,6 GHz — -100 dBm to -90 dBm · CMC 0,17 dB f = 4 GHz to 6,6 GHz — -90 dBm to -80 dBm · CMC 0,12 dB f = 4 GHz to 6,6 GHz — -80 dBm to -70 dBm · CMC 0,12 dB f = 4 GHz to 6,6 GHz — -70 dBm to -60 dBm · CMC 0,12 dB f = 4 GHz to 6,6 GHz — -60 dBm to -50 dBm · CMC 0,11 dB f = 4 GHz to 6,6 GHz — -50 dBm to -40 dBm · CMC 0,095 dB f = 4 GHz to 6,6 GHz — -40 dBm to -30 dBm · CMC 0,093 dB f = 4 GHz to 6,6 GHz — -30 dBm to -20 dBm · CMC 0,090 dB f = 4 GHz to 6,6 GHz — -20 dBm to -10 dBm · CMC 0,088 dB f = 4 GHz to 6,6 GHz — -10 dBm to 0 dBm · CMC 0,088 dB f = 4 GHz to 6,6 GHz — 0 dBm to 20 dBm · CMC 0,088 dB f = 6,6 GHz to 13,2 GHz — -110 dBm to -100 dBm · CMC 0,76 dB f = 6,6 GHz to 13,2 GHz — -100 dBm to -90 dBm · CMC 0,34 dB f = 6,6 GHz to 13,2 GHz — -90 dBm to -80 dBm · CMC 0,16 dB f = 6,6 GHz to 13,2 GHz — -80 dBm to -70 dBm · CMC 0,12 dB f = 6,6 GHz to 13,2 GHz — -70 dBm to -60 dBm · CMC 0,12 dB f = 6,6 GHz to 13,2 GHz — -60 dBm to -50 dBm · CMC 0,11 dB f = 6,6 GHz to 13,2 GHz — -50 dBm to -40 dBm · CMC 0,095 dB f = 6,6 GHz to 13,2 GHz — -40 dBm to -30 dBm · CMC 0,093 dB f = 6,6 GHz to 13,2 GHz — -30 dBm to -20 dBm · CMC 0,090 dB f = 6,6 GHz to 13,2 GHz — -20 dBm to -10 dBm · CMC 0,088 dB f = 6,6 GHz to 13,2 GHz — -10 dBm to 0 dBm · CMC 0,088 dB f = 6,6 GHz to 13,2 GHz — 0 dBm to 20 dBm · CMC 0,088 dB f = 13,2 GHz to 18 GHz — -100 dBm to -90 dBm · CMC 0,65 dB f = 13,2 GHz to 18 GHz — -90 dBm to -80 dBm · CMC 0,28 dB f = 13,2 GHz to 18 GHz — -80 dBm to -70 dBm · CMC 0,15 dB f = 13,2 GHz to 18 GHz — -70 dBm to -60 dBm · CMC 0,12 dB f = 13,2 GHz to 18 GHz — -60 dBm to -50 dBm · CMC 0,11 dB f = 13,2 GHz to 18 GHz — -50 dBm to -40 dBm · CMC 0,11 dB f = 13,2 GHz to 18 GHz — -40 dBm to -30 dBm · CMC 0,093 dB f = 13,2 GHz to 18 GHz — -30 dBm to -20 dBm · CMC 0,090 dB f = 13,2 GHz to 18 GHz — -20 dBm to -10 dBm · CMC 0,088 dB f = 13,2 GHz to 18 GHz — -10 dBm to 0 dBm · CMC 0,088 dB f = 13,2 GHz to 18 GHz — 0 dBm to 20 dBm · CMC 0,088 dB f = 18 GHz to 19,2 GHz — -100 dBm to -90 dBm · CMC 0,65 dB f = 18 GHz to 19,2 GHz — -90 dBm to -80 dBm · CMC 0,29 dB f = 18 GHz to 19,2 GHz — -80 dBm to -70 dBm · CMC 0,16 dB f = 18 GHz to 19,2 GHz — -70 dBm to -60 dBm · CMC 0,12 dB f = 18 GHz to 19,2 GHz — -60 dBm to -50 dBm · CMC 0,12 dB f = 18 GHz to 19,2 GHz — -50 dBm to -40 dBm · CMC 0,12 dB f = 18 GHz to 19,2 GHz — -40 dBm to -30 dBm · CMC 0,11 dB f = 18 GHz to 19,2 GHz — -30 dBm to -20 dBm · CMC 0,10 dB f = 18 GHz to 19,2 GHz — -20 dBm to -10 dBm · CMC 0,10 dB f = 18 GHz to 19,2 GHz — -10 dBm to 0 dBm · CMC 0,10 dB f = 18 GHz to 19,2 GHz — 0 dBm to 20 dBm · CMC 0,10 dB f = 19,2 GHz to 26,5 GHz — -100 dBm to -90 dBm · CMC 1,1 dB f = 19,2 GHz to 26,5 GHz — -90 dBm to -80 dBm · CMC 0,52 dB f = 19,2 GHz to 26,5 GHz — -80 dBm to -70 dBm · CMC 0,23 dB f = 19,2 GHz to 26,5 GHz — -70 dBm to -60 dBm · CMC 0,14 dB f = 19,2 GHz to 26,5 GHz — -60 dBm to -50 dBm · CMC 0,14 dB f = 19,2 GHz to 26,5 GHz — -50 dBm to -40 dBm · CMC 0,14 dB f = 19,2 GHz to 26,5 GHz — -40 dBm to -30 dBm · CMC 0,13 dB f = 19,2 GHz to 26,5 GHz — -30 dBm to -20 dBm · CMC 0,12 dB f = 19,2 GHz to 26,5 GHz — -20 dBm to -10 dBm · CMC 0,12 dB f = 19,2 GHz to 26,5 GHz — -10 dBm to 0 dBm · CMC 0,12 dB f = 19,2 GHz to 26,5 GHz — 0 dBm to 20 dBm · CMC 0,12 dB f = 26,5 GHz to 40 GHz — -80 dBm to -70 dBm · CMC 0,38 dB f = 26,5 GHz to 40 GHz — -70 dBm to -60 dBm · CMC 0,19 dB f = 26,5 GHz to 40 GHz — -60 dBm to -50 dBm · CMC 0,16 dB f = 26,5 GHz to 40 GHz — -50 dBm to -40 dBm · CMC 0,16 dB f = 26,5 GHz to 40 GHz — -40 dBm to -30 dBm · CMC 0,14 dB f = 26,5 GHz to 40 GHz — -30 dBm to -20 dBm · CMC 0,14 dB f = 26,5 GHz to 40 GHz — -20 dBm to -10 dBm · CMC 0,14 dB f = 26,5 GHz to 40 GHz — -10 dBm to 0 dBm · CMC 0,14 dB f = 26,5 GHz to 40 GHz — 0 dBm to 20 dBm · CMC 0,14 dB f = 40 GHz to 50 GHz — -40 dBm to -30 dBm · CMC 0,20 dB f = 40 GHz to 50 GHz — -30 dBm to -20 dBm · CMC 0,20 dB f = 40 GHz to 50 GHz — -20 dBm to -10 dBm · CMC 0,17 dB f = 40 GHz to 50 GHz — -10 dBm to 0 dBm · CMC 0,16 dB f = 40 GHz to 50 GHz — 0 dBm to 20 dBm · CMC 0,16 dB RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/48 | |
| 45 | Attenuators Couplers Amplifiers - scalar transmission Generators Network analysers Radio communication testers - relative output power level Network analysers Spectrum analysers Antenna and cable system analysers Measuring receivers Radio communication testers - relative measured power level |
Calibration — RF electrical quantities f = 9 kHz to 100 kHz — -60 dB from -50 dB · CMC 0,095 dB f = 9 kHz to 100 kHz — -50 dB from -30 dB · CMC 0,023 dB f = 9 kHz to 100 kHz — 30 dB from 20 dB · CMC 0,016 dB f = 100 kHz to 10 MHz — -131 dB to -101 dB · CMC 0,13 dB + δ f = 100 kHz to 10 MHz — -101 dB to -60 dB · CMC (0,040 + 0,0005 - |P|) dB f = 100 kHz to 10 MHz — -60 dB to 50 dB · CMC (0,009 + 0,0005 - |P|) dB f = 10 MHz to 3,05 GHz — -134 dB to -104 dB · CMC 0,13 dB + δ f = 10 MHz to 3,05 GHz — -104 dB to -61 dB · CMC (0,040 + 0,0005 - |P|) dB f = 10 MHz to 3,05 GHz — -61 dB to 50 dB · CMC (0,009 + 0,0005 - |P|) dB f = 3,05 GHz to 6,6 GHz — -126 dB to -96 dB · CMC 0,13 dB + δ f = 3,05 GHz to 6,6 GHz — -96 dB to -57dB · CMC (0,040 + 0,0005 - |P|) dB f = 3,05 GHz to 6,6 GHz — -57dB to 30 dB · CMC (0,009 + 0,0005 - |P|) dB f = 6,6 GHz to 13,2 GHz — -117 dB to -87 dB · CMC 0,12 dB + δ f = 6,6 GHz to 13,2 GHz — -87 dB to -52 dB · CMC (0,040 + 0,0005 - |P|) dB f = 6,6 GHz to 13,2 GHz — -52 dB to 30 dB · CMC (0,009 + 0,0005 - |P|) dB f = 13,2 GHz to 19,2 GHz — -109 dB to -79 dB · CMC 0,12 dB + δ f = 13,2 GHz to 19,2 GHz — -79 dB to -44 dB · CMC (0,040 + 0,0005 - |P|) dB f = 13,2 GHz to 19,2 GHz — -44 dB to 30 dB · CMC (0,009 + 0,0005 - |P|) dB f = 19,2 GHz to 26,5 GHz — -102 dB to -72 dB · CMC 0,12 dB + δ f = 19,2 GHz to 26,5 GHz — -72 dB to -34 dB · CMC (0,040 + 0,0005 - |P|) dB f = 19,2 GHz to 26,5 GHz — -34 dB to 30 dB · CMC (0,009 + 0,0005 - |P|) dB f = 26,5 GHz to 40 GHz — -96 dB to -66 dB · CMC 0,12 dB + δ f = 26,5 GHz to 40 GHz — -66 dB to -51 dB · CMC (0,040 + 0,0005 - |P|) dB f = 26,5 GHz to 40 GHz — -51 dB to 30 dB · CMC (0,009 + 0,0005 - |P|) dB RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/32 LMEEiO/33 LMEEiO/34 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/44 LMEEiO/48 | |
| 46 | Generators Radio communication testers - generated AM modulation depth Analogue modulation analysers Radio communication testers Measuring receivers - measured AM modulation depth |
Calibration — RF electrical quantities f = 50 kHz to 10 MHz; modulation frequency 20 Hz to 50 kHz; modulation depth — 0 % to 99 % · CMC 0,75 % f = 10 MHz to 3 GHz; modulation frequency 30 Hz to 200 kHz; modulation depth — 0 % to 99 % · CMC 0,5 % f = 3 GHz to 5,2 GHz; modulation frequency 30 Hz to 200 kHz; modulation depth — 0 % to 99 % · CMC 0,8 % f = 5,2 GHz to 26,5 GHz; modulation frequency 50 Hz to 100 kHz; modulation depth — 5 % to 99 % · CMC 1,5 % RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/32 LMEEiO/44 | |
| 47 | Generators Radio communication testers - generated FM frequency deviation Analogue modulation analysers Radio communication testers Measuring receivers - measured FM frequency deviation |
Calibration — RF electrical quantities f = 50 kHz to 10 MHz; modulation frequency 10 Hz to 50 kHz; frequency deviation — 100 Hz to 150 kHz · CMC 0,5 % f = 10 MHz to 5,2 GHz; modulation frequency 10 Hz to 200 kHz; frequency deviation — 100 Hz to 700 kHz · CMC 0,5 % f = 5,2 GHz to 26,5 GHz; modulation frequency 50 Hz to 200 kHz; frequency deviation — 250 kHz to 400 kHz · CMC 1,0 % RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/32 LMEEiO/44 | |
| 48 | Generators Radio communication testers - generated FM phase deviation Analogue modulation analysers Radio communication testers Measuring receivers - measured FM phase deviation |
Calibration — RF electrical quantities f = 50 kHz to 10 MHz; modulation frequency 10 Hz to 20 kHz; phase deviation — 0,01 rad to 450 rad · CMC 1,0 % f = 10 MHz to 5,2 GHz; modulation frequency 10 Hz to 100 kHz; phase deviation — 0,01 rad to 24999 rad · CMC 1,0 % f = 5,2 GHz to 26,5 GHz; modulation frequency 200 Hz to 20 kHz; phase deviation — 0,3 rad to 24999 rad · CMC 1,0 % RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/32 LMEEiO/44 | |
| 49 | Generators Radio communication testers - signal distortion generators |
Calibration — RF electrical quantities -80 dB to 0 dB · CMC 1 dB RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/32 LMEEiO/44 | |
| 50 | Radio communication testers - modulation frequency (AM, FM, PM) |
Calibration — RF electrical quantities 20 Hz to 200 kHz · CMC 0,06 Hz RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/32 LMEEiO/44 | |
| 51 | Distortion analysers Modulation analysers Radio communication testers - measured signal distortion |
Calibration — RF electrical quantities < 50 kHz · CMC 0,5 dB 50 kHz to 100 kHz · CMC 0,7 dB 100 kHz to 300 kHz · CMC 1,5 dB RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/44 | |
| 52 | Power sensors - calibration factor |
Calibration — RF electrical quantities 10 % to 150 % — 9 kHz to 300 MHz · CMC 0,56 % 10 % to 150 % — 300 MHz to 8,5 GHz · CMC 0,71 % 10 % to 150 % — 8,5 GHz to 12,5 GHz · CMC 0,85 % 10 % to 150 % — 12,5 GHz to 18,0 GHz · CMC 0,91 % 10 % to 150 % — 18,0 GHz to 26,5 GHz · CMC 1,7 % 10 % to 150 % — 26,5 GHz to 40 GHz · CMC 2,5 % 10 % to 150 % — 40 GHz to 50 GHz · CMC 3,3 % RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/33 | |
| 53 | Frequency meters Power sensors Fixed loads (terminations, resistors) Fixed attenuators Variable attenuators Filters Directional couplers Switches Antenna and cable system analysers Measuring receivers Amplifiers - reflection coefficient S11 / S22 |
Calibration — RF electrical quantities 9 kHz to 50 GHz — 0,0 to 1,0 · CMC CMC matrix on the following pages CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0 — 9 kHz to 300 kHz · CMC 0,0047 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0 — 300 kHz to 10 MHz · CMC 0,0053 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0 — 10 MHz to 500 MHz · CMC 0,0073 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0 — 500 MHz to 2 GHz · CMC 0,0058 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0 — 2 GHz to 10 GHz · CMC 0,0075 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0 — 10 GHz to 18 GHz · CMC 0,012 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2 — 9 kHz to 300 kHz · CMC 0,0062 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2 — 300 kHz to 10 MHz · CMC 0,0072 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2 — 10 MHz to 500 MHz · CMC 0,0089 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2 — 500 MHz to 2 GHz · CMC 0,0075 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2 — 2 GHz to 10 GHz · CMC 0,0094 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2 — 10 GHz to 18 GHz · CMC 0,015 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6 — 9 kHz to 300 kHz · CMC 0,0096 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6 — 300 kHz to 10 MHz · CMC 0,014 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6 — 10 MHz to 500 MHz · CMC 0,015 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6 — 500 MHz to 2 GHz · CMC 0,013 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6 — 2 GHz to 10 GHz · CMC 0,016 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6 — 10 GHz to 18 GHz · CMC 0,026 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0 — 9 kHz to 300 kHz · CMC 0,015 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0 — 300 kHz to 10 MHz · CMC 0,024 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0 — 10 MHz to 500 MHz · CMC 0,026 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0 — 500 MHz to 2 GHz · CMC 0,021 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0 — 2 GHz to 10 GHz · CMC 0,027 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0 — 10 GHz to 18 GHz · CMC 0,045 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0 — 9 kHz to 300 kHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0 — 300 kHz to 10 MHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0 — 10 MHz to 500 MHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0 — 500 MHz to 2 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0 — 2 GHz to 10 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0 — 10 GHz to 18 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2 — 9 kHz to 300 kHz · CMC 1,8° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2 — 300 kHz to 10 MHz · CMC 2,1° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2 — 10 MHz to 500 MHz · CMC 2,6° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2 — 500 MHz to 2 GHz · CMC 2,2° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2 — 2 GHz to 10 GHz · CMC 2,5° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2 — 10 GHz to 18 GHz · CMC 4,2° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6 — 9 kHz to 300 kHz · CMC 0,91° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6 — 300 kHz to 10 MHz · CMC 1,3° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6 — 10 MHz to 500 MHz · CMC 1,5° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6 — 500 MHz to 2 GHz · CMC 1,2° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6 — 2 GHz to 10 GHz · CMC 1,5° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6 — 10 GHz to 18 GHz · CMC 2,4° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0 — 9 kHz to 300 kHz · CMC 0,82° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0 — 300 kHz to 10 MHz · CMC 1,4° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0 — 10 MHz to 500 MHz · CMC 1,5° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0 — 500 MHz to 2 GHz · CMC 1,2° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0 — 2 GHz to 10 GHz · CMC 1,5° CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0 — 10 GHz to 18 GHz · CMC 2,6° CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,0 — 9 kHz to 30 kHz · CMC 0,0063 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,0 — 30 kHz to 1,3 GHz · CMC 0,0063 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,0 — 1,3 GHz to 3 GHz · CMC 0,011 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,2 — 9 kHz to 30 kHz · CMC 0,0079 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,2 — 30 kHz to 1,3 GHz · CMC 0,0078 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,2 — 1,3 GHz to 3 GHz · CMC 0,014 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,6 — 9 kHz to 30 kHz · CMC 0,013 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,6 — 30 kHz to 1,3 GHz · CMC 0,012 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,6 — 1,3 GHz to 3 GHz · CMC 0,025 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 1,0 — 9 kHz to 30 kHz · CMC 0,019 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 1,0 — 30 kHz to 1,3 GHz · CMC 0,018 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 1,0 — 1,3 GHz to 3 GHz · CMC 0,043 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,0 — 9 kHz to 30 kHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,0 — 30 kHz to 1,3 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,0 — 1,3 GHz to 3 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,2 — 9 kHz to 30 kHz · CMC 2,3° CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,2 — 30 kHz to 1,3 GHz · CMC 2,3° CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,2 — 1,3 GHz to 3 GHz · CMC 3,9° CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,6 — 9 kHz to 30 kHz · CMC 1,2° CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,6 — 30 kHz to 1,3 GHz · CMC 1,2° CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,6 — 1,3 GHz to 3 GHz · CMC 2,4° CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 1,0 — 9 kHz to 30 kHz · CMC 1,1° CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 1,0 — 30 kHz to 1,3 GHz · CMC 1,1° CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 1,0 — 1,3 GHz to 3 GHz · CMC 2,5° CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 — 9 kHz to 10 MHz · CMC 0,012 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 — 10 MHz to 45 MHz · CMC 0,0073 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 — 45 MHz to 500 MHz · CMC 0,0073 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 — 500 MHz to 2 GHz · CMC 0,0025 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 — 2 GHz to 10 GHz · CMC 0,0033 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 — 10 GHz to 20 GHz · CMC 0,0061 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 — 20 GHz to 26,5 GHz · CMC 0,0096 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 — 9 kHz to 10 MHz · CMC 0,014 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 — 10 MHz to 45 MHz · CMC 0,011 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 — 45 MHz to 500 MHz · CMC 0,0096 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 — 500 MHz to 2 GHz · CMC 0,0037 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 — 2 GHz to 10 GHz · CMC 0,0049 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 — 10 GHz to 20 GHz · CMC 0,0081 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 — 20 GHz to 26,5 GHz · CMC 0,013 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 — 9 kHz to 10 MHz · CMC 0,022 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 — 10 MHz to 45 MHz · CMC 0,022 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 — 45 MHz to 500 MHz · CMC 0,017 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 — 500 MHz to 2 GHz · CMC 0,0073 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 — 2 GHz to 10 GHz · CMC 0,0099 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 — 10 GHz to 20 GHz · CMC 0,014 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 — 20 GHz to 26,5 GHz · CMC 0,021 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 — 9 kHz to 10 MHz · CMC 0,036 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 — 10 MHz to 45 MHz · CMC 0,036 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 — 45 MHz to 500 MHz · CMC 0,028 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 — 500 MHz to 2 GHz · CMC 0,013 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 — 2 GHz to 10 GHz · CMC 0,017 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 — 10 GHz to 20 GHz · CMC 0,023 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 — 20 GHz to 26,5 GHz · CMC 0,033 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 — 9 kHz to 10 MHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 — 10 MHz to 45 MHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 — 45 MHz to 500 MHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 — 500 MHz to 2 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 — 2 GHz to 10 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 — 10 GHz to 20 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 — 20 GHz to 26,5 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 — 9 kHz to 10 MHz · CMC 4,0° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 — 10 MHz to 45 MHz · CMC 3,1° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 — 45 MHz to 500 MHz · CMC 2,8° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 — 500 MHz to 2 GHz · CMC 1,1° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 — 2 GHz to 10 GHz · CMC 1,5° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 — 10 GHz to 20 GHz · CMC 2,3° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 — 20 GHz to 26,5 GHz · CMC 3,5° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 — 9 kHz to 10 MHz · CMC 2,1° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 — 10 MHz to 45 MHz · CMC 2,1° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 — 45 MHz to 500 MHz · CMC 1,6° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 — 500 MHz to 2 GHz · CMC 0,70° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 — 2 GHz to 10 GHz · CMC 0,95° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 — 10 GHz to 20 GHz · CMC 1,4° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 — 20 GHz to 26,5 GHz · CMC 2,0° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 — 9 kHz to 10 MHz · CMC 2,1° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 — 10 MHz to 45 MHz · CMC 2,1° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 — 45 MHz to 500 MHz · CMC 1,6° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 — 500 MHz to 2 GHz · CMC 0,73° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 — 2 GHz to 10 GHz · CMC 0,98° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 — 10 GHz to 20 GHz · CMC 1,3° CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 — 20 GHz to 26,5 GHz · CMC 1,9° CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0 — 9 kHz to 45 MHz · CMC 0,015 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0 — 45 MHz to 2 GHz · CMC 0,0042 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0 — 2 GHz to 10 GHz · CMC 0,0055 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0 — 10 GHz to 20 GHz · CMC 0,0084 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0 — 20 GHz to 40 GHz · CMC 0,014 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0 — 40 GHz to 50 GHz · CMC 0,013 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2 — 9 kHz to 45 MHz · CMC 0,017 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2 — 45 MHz to 2 GHz · CMC 0,0058 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2 — 2 GHz to 10 GHz · CMC 0,0076 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2 — 10 GHz to 20 GHz · CMC 0,012 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2 — 20 GHz to 40 GHz · CMC 0,017 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2 — 40 GHz to 50 GHz · CMC 0,017 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6 — 9 kHz to 45 MHz · CMC 0,025 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6 — 45 MHz to 2 GHz · CMC 0,011 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6 — 2 GHz to 10 GHz · CMC 0,015 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6 — 10 GHz to 20 GHz · CMC 0,021 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6 — 20 GHz to 40 GHz · CMC 0,029 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6 — 40 GHz to 50 GHz · CMC 0,030 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0 — 9 kHz to 45 MHz · CMC 0,037 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0 — 45 MHz to 2 GHz · CMC 0,017 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0 — 2 GHz to 10 GHz · CMC 0,024 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0 — 10 GHz to 20 GHz · CMC 0,037 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0 — 20 GHz to 40 GHz · CMC 0,049 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0 — 40 GHz to 50 GHz · CMC 0,051 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0 — 9 kHz to 45 MHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0 — 45 MHz to 2 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0 — 2 GHz to 10 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0 — 10 GHz to 20 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0 — 20 GHz to 40 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0 — 40 GHz to 50 GHz · CMC 180° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2 — 9 kHz to 45 MHz · CMC 4,8° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2 — 45 MHz to 2 GHz · CMC 1,7° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2 — 2 GHz to 10 GHz · CMC 2,2° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2 — 10 GHz to 20 GHz · CMC 3,2° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2 — 20 GHz to 40 GHz · CMC 4,8° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2 — 40 GHz to 50 GHz · CMC 8,0° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6 — 9 kHz to 45 MHz · CMC 2,4° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6 — 45 MHz to 2 GHz · CMC 0,97° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6 — 2 GHz to 10 GHz · CMC 1,4° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6 — 10 GHz to 20 GHz · CMC 2,1° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6 — 20 GHz to 40 GHz · CMC 2,8° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6 — 40 GHz to 50 GHz · CMC 4,3° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0 — 9 kHz to 45 MHz · CMC 2,1° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0 — 45 MHz to 2 GHz · CMC 0,96° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0 — 2 GHz to 10 GHz · CMC 1,4° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0 — 10 GHz to 20 GHz · CMC 2,2° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0 — 20 GHz to 40 GHz · CMC 2,9° CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0 — 40 GHz to 50 GHz · CMC 4,3° RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/34 LMEEiO/48 | |
| 54 | Fixed attenuators Variable attenuators Filters Directional couplers Switches Antenna and cable system analysers Amplifiers - transmission S21 / S12 |
Calibration — RF electrical quantities 9 kHz to 50 GHz — -80 dB to 60 dB · CMC CMC matrix on the following pages CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB — 9 kHz to 300 kHz · CMC 1,4 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB — 300 kHz to 10 MHz · CMC 0,74 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB — 10 MHz to 500 MHz · CMC 0,53 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB — 500 MHz to 2 GHz · CMC 0,38 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB — 2 GHz to 10 GHz · CMC 0,45 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB — 10 GHz to 18 GHz · CMC 0,51 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB — 9 kHz to 300 kHz · CMC 0,28 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB — 300 kHz to 10 MHz · CMC 0,22 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB — 10 MHz to 500 MHz · CMC 0,20 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB — 500 MHz to 2 GHz · CMC 0,090 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB — 2 GHz to 10 GHz · CMC 0,16 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB — 10 GHz to 18 GHz · CMC 0,22 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB — 9 kHz to 300 kHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB — 300 kHz to 10 MHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB — 10 MHz to 500 MHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB — 500 MHz to 2 GHz · CMC 0,050 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB — 2 GHz to 10 GHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB — 10 GHz to 18 GHz · CMC 0,18 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB — 9 kHz to 300 kHz · CMC 0,079 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB — 300 kHz to 10 MHz · CMC 0,079 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB — 10 MHz to 500 MHz · CMC 0,078 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB — 500 MHz to 2 GHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB — 2 GHz to 10 GHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB — 10 GHz to 18 GHz · CMC 0,17 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB — 9 kHz to 300 kHz · CMC 0,047 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB — 300 kHz to 10 MHz · CMC 0,047 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB — 10 MHz to 500 MHz · CMC 0,047 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB — 500 MHz to 2 GHz · CMC 0,024 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB — 2 GHz to 10 GHz · CMC 0,092 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB — 10 GHz to 18 GHz · CMC 0,16 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB — 9 kHz to 300 kHz · CMC 0,071 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB — 300 kHz to 10 MHz · CMC 0,071 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB — 10 MHz to 500 MHz · CMC 0,071 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB — 500 MHz to 2 GHz · CMC 0,034 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB — 2 GHz to 10 GHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB — 10 GHz to 18 GHz · CMC 0,16 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB — 9 kHz to 300 kHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB — 300 kHz to 10 MHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB — 10 MHz to 500 MHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB — 500 MHz to 2 GHz · CMC 0,069 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB — 2 GHz to 10 GHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB — 10 GHz to 18 GHz · CMC 0,20 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB — 9 kHz to 300 kHz · CMC 0,20 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB — 300 kHz to 10 MHz · CMC 0,20 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB — 10 MHz to 500 MHz · CMC 0,20 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB — 500 MHz to 2 GHz · CMC 0,079 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB — 2 GHz to 10 GHz · CMC 0,15 CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB — 10 GHz to 18 GHz · CMC 0,21 CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB — 9 kHz to 300 kHz · CMC 9,6° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB — 300 kHz to 10 MHz · CMC 5,1° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB — 10 MHz to 500 MHz · CMC 3,7° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB — 500 MHz to 2 GHz · CMC 2,6° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB — 2 GHz to 10 GHz · CMC 3,1° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB — 10 GHz to 18 GHz · CMC 3,4° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB — 9 kHz to 300 kHz · CMC 1,9° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB — 300 kHz to 10 MHz · CMC 1,4° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB — 10 MHz to 500 MHz · CMC 1,4° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB — 500 MHz to 2 GHz · CMC 0,60° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB — 2 GHz to 10 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB — 10 GHz to 18 GHz · CMC 1,5° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB — 9 kHz to 300 kHz · CMC 0,86° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB — 300 kHz to 10 MHz · CMC 0,81° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB — 10 MHz to 500 MHz · CMC 0,80° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB — 500 MHz to 2 GHz · CMC 0,34° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB — 2 GHz to 10 GHz · CMC 0,80° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB — 10 GHz to 18 GHz · CMC 1,2° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB — 9 kHz to 300 kHz · CMC 0,55° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB — 300 kHz to 10 MHz · CMC 0,55° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB — 10 MHz to 500 MHz · CMC 0,55° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB — 500 MHz to 2 GHz · CMC 0,24° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB — 2 GHz to 10 GHz · CMC 0,71° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB — 10 GHz to 18 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB — 9 kHz to 300 kHz · CMC 0,31° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB — 300 kHz to 10 MHz · CMC 0,31° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB — 10 MHz to 500 MHz · CMC 0,31° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB — 500 MHz to 2 GHz · CMC 0,16° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB — 2 GHz to 10 GHz · CMC 0,59° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB — 10 GHz to 18 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB — 9 kHz to 300 kHz · CMC 0,47° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB — 300 kHz to 10 MHz · CMC 0,47° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB — 10 MHz to 500 MHz · CMC 0,47° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB — 500 MHz to 2 GHz · CMC 0,23° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB — 2 GHz to 10 GHz · CMC 0,67° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB — 10 GHz to 18 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB — 9 kHz to 300 kHz · CMC 0,75° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB — 300 kHz to 10 MHz · CMC 0,75° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB — 10 MHz to 500 MHz · CMC 0,75° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB — 500 MHz to 2 GHz · CMC 0,49° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB — 2 GHz to 10 GHz · CMC 0,95° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB — 10 GHz to 18 GHz · CMC 1,4° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB — 9 kHz to 300 kHz · CMC 1,4° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB — 300 kHz to 10 MHz · CMC 1,4° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB — 10 MHz to 500 MHz · CMC 1,4° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB — 500 MHz to 2 GHz · CMC 0,57° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB — 2 GHz to 10 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB — 10 GHz to 18 GHz · CMC 1,5° CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -80,0 dB — 9 kHz to 30 kHz · CMC 0,54 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -80,0 dB — 30 kHz to 1,3 GHz · CMC 0,37 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -80,0 dB — 1,3 GHz to 3 GHz · CMC 0,40 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -60,0 dB — 9 kHz to 30 kHz · CMC 0,20 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -60,0 dB — 30 kHz to 1,3 GHz · CMC 0,15 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -60,0 dB — 1,3 GHz to 3 GHz · CMC 0,17 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -40,0 dB — 9 kHz to 30 kHz · CMC 0,13 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -40,0 dB — 30 kHz to 1,3 GHz · CMC 0,10 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -40,0 dB — 1,3 GHz to 3 GHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -20,0 dB — 9 kHz to 30 kHz · CMC 0,081 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -20,0 dB — 30 kHz to 1,3 GHz · CMC 0,073 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -20,0 dB — 1,3 GHz to 3 GHz · CMC 0,093 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 0,0 dB — 9 kHz to 30 kHz · CMC 0,057 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 0,0 dB — 30 kHz to 1,3 GHz · CMC 0,050 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 0,0 dB — 1,3 GHz to 3 GHz · CMC 0,070 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 20,0 dB — 9 kHz to 30 kHz · CMC 0,081 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 20,0 dB — 30 kHz to 1,3 GHz · CMC 0,074 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 20,0 dB — 1,3 GHz to 3 GHz · CMC 0,093 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 40,0 dB — 9 kHz to 30 kHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 40,0 dB — 30 kHz to 1,3 GHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 40,0 dB — 1,3 GHz to 3 GHz · CMC 0,13 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 60,0 dB — 9 kHz to 30 kHz · CMC 0,21 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 60,0 dB — 30 kHz to 1,3 GHz · CMC 0,15 CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 60,0 dB — 1,3 GHz to 3 GHz · CMC 0,18 CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -80,0 dB — 9 kHz to 30 kHz · CMC 3,7° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -80,0 dB — 30 kHz to 1,3 GHz · CMC 2,7° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -80,0 dB — 1,3 GHz to 3 GHz · CMC 2,9° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -60,0 dB — 9 kHz to 30 kHz · CMC 1,4° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -60,0 dB — 30 kHz to 1,3 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -60,0 dB — 1,3 GHz to 3 GHz · CMC 1,2° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -40,0 dB — 9 kHz to 30 kHz · CMC 0,83° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -40,0 dB — 30 kHz to 1,3 GHz · CMC 0,68° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -40,0 dB — 1,3 GHz to 3 GHz · CMC 0,81° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -20,0 dB — 9 kHz to 30 kHz · CMC 0,54° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -20,0 dB — 30 kHz to 1,3 GHz · CMC 0,49° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -20,0 dB — 1,3 GHz to 3 GHz · CMC 0,62° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 0,0 dB — 9 kHz to 30 kHz · CMC 0,38° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 0,0 dB — 30 kHz to 1,3 GHz · CMC 0,33° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 0,0 dB — 1,3 GHz to 3 GHz · CMC 0,47° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 20,0 dB — 9 kHz to 30 kHz · CMC 0,54° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 20,0 dB — 30 kHz to 1,3 GHz · CMC 0,50° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 20,0 dB — 1,3 GHz to 3 GHz · CMC 0,63° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 40,0 dB — 9 kHz to 30 kHz · CMC 0,80° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 40,0 dB — 30 kHz to 1,3 GHz · CMC 0,69° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 40,0 dB — 1,3 GHz to 3 GHz · CMC 0,84° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 60,0 dB — 9 kHz to 30 kHz · CMC 1,4° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 60,0 dB — 30 kHz to 1,3 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 60,0 dB — 1,3 GHz to 3 GHz · CMC 1,4° CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB — 9 kHz to 10 MHz · CMC 0,75 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB — 10 MHz to 45 MHz · CMC 0,55 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB — 45 MHz to 500 MHz · CMC 0,55 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB — 500 MHz to 2 GHz · CMC 0,43 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB — 2 GHz to 10 GHz · CMC 0,46 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB — 10 GHz to 20 GHz · CMC 0,49 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB — 20 GHz to 26,5 GHz · CMC 0,52 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB — 9 kHz to 10 MHz · CMC 0,24 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB — 10 MHz to 45 MHz · CMC 0,22 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB — 45 MHz to 500 MHz · CMC 0,22 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB — 500 MHz to 2 GHz · CMC 0,15 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB — 2 GHz to 10 GHz · CMC 0,17 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB — 10 GHz to 20 GHz · CMC 0,20 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB — 20 GHz to 26,5 GHz · CMC 0,23 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB — 9 kHz to 10 MHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB — 10 MHz to 45 MHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB — 45 MHz to 500 MHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB — 500 MHz to 2 GHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB — 2 GHz to 10 GHz · CMC 0,13 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB — 10 GHz to 20 GHz · CMC 0,17 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB — 20 GHz to 26,5 GHz · CMC 0,20 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB — 9 kHz to 10 MHz · CMC 0,098 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB — 10 MHz to 45 MHz · CMC 0,098 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB — 45 MHz to 500 MHz · CMC 0,098 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB — 500 MHz to 2 GHz · CMC 0,079 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB — 2 GHz to 10 GHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB — 10 GHz to 20 GHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB — 20 GHz to 26,5 GHz · CMC 0,17 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB — 9 kHz to 10 MHz · CMC 0,066 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB — 10 MHz to 45 MHz · CMC 0,066 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB — 45 MHz to 500 MHz · CMC 0,066 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB — 500 MHz to 2 GHz · CMC 0,066 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB — 2 GHz to 10 GHz · CMC 0,092 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB — 10 GHz to 20 GHz · CMC 0,13 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB — 20 GHz to 26,5 GHz · CMC 0,16 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB — 9 kHz to 10 MHz · CMC 0,099 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB — 10 MHz to 45 MHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB — 45 MHz to 500 MHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB — 500 MHz to 2 GHz · CMC 0,097 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB — 2 GHz to 10 GHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB — 10 GHz to 20 GHz · CMC 0,15 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB — 20 GHz to 26,5 GHz · CMC 0,19 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB — 9 kHz to 10 MHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB — 10 MHz to 45 MHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB — 45 MHz to 500 MHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB — 500 MHz to 2 GHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB — 2 GHz to 10 GHz · CMC 0,13 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB — 10 GHz to 20 GHz · CMC 0,17 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB — 20 GHz to 26,5 GHz · CMC 0,20 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB — 9 kHz to 10 MHz · CMC 0,19 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB — 10 MHz to 45 MHz · CMC 0,13 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB — 45 MHz to 500 MHz · CMC 0,13 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB — 500 MHz to 2 GHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB — 2 GHz to 10 GHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB — 10 GHz to 20 GHz · CMC 0,18 CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB — 20 GHz to 26,5 GHz · CMC 0,21 CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB — 9 kHz to 10 MHz · CMC 5,2° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB — 10 MHz to 45 MHz · CMC 3,8° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB — 45 MHz to 500 MHz · CMC 3,8° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB — 500 MHz to 2 GHz · CMC 3,0° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB — 2 GHz to 10 GHz · CMC 3,1° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB — 10 GHz to 20 GHz · CMC 3,3° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB — 20 GHz to 26,5 GHz · CMC 3,5° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB — 9 kHz to 10 MHz · CMC 1,6° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB — 10 MHz to 45 MHz · CMC 11,5° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB — 45 MHz to 500 MHz · CMC 1,5° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB — 500 MHz to 2 GHz · CMC 0,96° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB — 2 GHz to 10 GHz · CMC 1,2° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB — 10 GHz to 20 GHz · CMC 1,4° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB — 20 GHz to 26,5 GHz · CMC 1,6° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB — 9 kHz to 10 MHz · CMC 0,94° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB — 10 MHz to 45 MHz · CMC 0,93° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB — 45 MHz to 500 MHz · CMC 0,93° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB — 500 MHz to 2 GHz · CMC 0,71° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB — 2 GHz to 10 GHz · CMC 0,86° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB — 10 GHz to 20 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB — 20 GHz to 26,5 GHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB — 9 kHz to 10 MHz · CMC 0,68° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB — 10 MHz to 45 MHz · CMC 0,68° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB — 45 MHz to 500 MHz · CMC 0,68° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB — 500 MHz to 2 GHz · CMC 0,53° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB — 2 GHz to 10 GHz · CMC 0,71° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB — 10 GHz to 20 GHz · CMC 0,94° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB — 20 GHz to 26,5 GHz · CMC 1,2° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB — 9 kHz to 10 MHz · CMC 0,44° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB — 10 MHz to 45 MHz · CMC 0,44° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB — 45 MHz to 500 MHz · CMC 0,44° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB — 500 MHz to 2 GHz · CMC 0,44° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB — 2 GHz to 10 GHz · CMC 0,61° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB — 10 GHz to 20 GHz · CMC 0,84° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB — 20 GHz to 26,5 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB — 9 kHz to 10 MHz · CMC 0,68° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB — 10 MHz to 45 MHz · CMC 0,67° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB — 45 MHz to 500 MHz · CMC 0,69° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB — 500 MHz to 2 GHz · CMC 0,69° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB — 2 GHz to 10 GHz · CMC 0,80° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB — 10 GHz to 20 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB — 20 GHz to 26,5 GHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB — 9 kHz to 10 MHz · CMC 0,93° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB — 10 MHz to 45 MHz · CMC 0,74° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB — 45 MHz to 500 MHz · CMC 0,76° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB — 500 MHz to 2 GHz · CMC 0,76° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB — 2 GHz to 10 GHz · CMC 0,87° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB — 10 GHz to 20 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB — 20 GHz to 26,5 GHz · CMC 1,4° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB — 9 kHz to 10 MHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB — 10 MHz to 45 MHz · CMC 0,82° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB — 45 MHz to 500 MHz · CMC 0,83° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB — 500 MHz to 2 GHz · CMC 0,83° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB — 2 GHz to 10 GHz · CMC 0,95° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB — 10 GHz to 20 GHz · CMC 1,2° CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB — 20 GHz to 26,5 GHz · CMC 1,5° CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB — 9 kHz to 10 MHz · CMC 0,75 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB — 10 MHz to 45 MHz · CMC 0,55 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB — 45 MHz to 500 MHz · CMC 0,55 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB — 500 MHz to 2 GHz · CMC 0,41 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB — 2 GHz to 10 GHz · CMC 0,42 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB — 10 GHz to 20 GHz · CMC 0,45 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB — 20 GHz to 35 GHz · CMC 0,48 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB — 35 GHz to 44 GHz · CMC 0,71 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB — 44 GHz to 50 GHz · CMC 1,9 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB — 9 kHz to 10 MHz · CMC 0,24 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB — 10 MHz to 45 MHz · CMC 0,22 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB — 45 MHz to 500 MHz · CMC 0,19 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB — 500 MHz to 2 GHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB — 2 GHz to 10 GHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB — 10 GHz to 20 GHz · CMC 0,16 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB — 20 GHz to 35 GHz · CMC 0,19 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB — 35 GHz to 44 GHz · CMC 0,22 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB — 44 GHz to 50 GHz · CMC 0,39 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB — 9 kHz to 10 MHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB — 10 MHz to 45 MHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB — 45 MHz to 500 MHz · CMC 0,086 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB — 500 MHz to 2 GHz · CMC 0,079 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB — 2 GHz to 10 GHz · CMC 0,093 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB — 10 GHz to 20 GHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB — 20 GHz to 35 GHz · CMC 0,15 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB — 35 GHz to 44 GHz · CMC 0,16 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB — 44 GHz to 50 GHz · CMC 0,23 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB — 9 kHz to 10 MHz · CMC 0,098 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB — 10 MHz to 45 MHz · CMC 0,098 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB — 45 MHz to 500 MHz · CMC 0,065 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB — 500 MHz to 2 GHz · CMC 0,066 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB — 2 GHz to 10 GHz · CMC 0,080 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB — 10 GHz to 20 GHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB — 20 GHz to 35 GHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB — 35 GHz to 44 GHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB — 44 GHz to 50 GHz · CMC 0,20 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB — 9 kHz to 10 MHz · CMC 0,066 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB — 10 MHz to 45 MHz · CMC 0,066 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB — 45 MHz to 500 MHz · CMC 0,056 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB — 500 MHz to 2 GHz · CMC 0,052 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB — 2 GHz to 10 GHz · CMC 0,066 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB — 10 GHz to 20 GHz · CMC 0,089 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB — 20 GHz to 35 GHz · CMC 0,13 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB — 35 GHz to 44 GHz · CMC 0,13 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB — 44 GHz to 50 GHz · CMC 0,19 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB — 9 kHz to 10 MHz · CMC 0,17 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB — 10 MHz to 45 MHz · CMC 0,17 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB — 45 MHz to 500 MHz · CMC 0,064 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB — 500 MHz to 2 GHz · CMC 0,083 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB — 2 GHz to 10 GHz · CMC 0,92 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB — 10 GHz to 20 GHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB — 20 GHz to 35 GHz · CMC 0,16 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB — 35 GHz to 44 GHz · CMC 0,17 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB — 44 GHz to 50 GHz · CMC 0,23 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB — 9 kHz to 10 MHz · CMC 0,20 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB — 10 MHz to 45 MHz · CMC 0,20 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB — 45 MHz to 500 MHz · CMC 0,075 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB — 500 MHz to 2 GHz · CMC 0,095 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB — 2 GHz to 10 GHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB — 10 GHz to 20 GHz · CMC 0,13 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB — 20 GHz to 35 GHz · CMC 0,17 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB — 35 GHz to 44 GHz · CMC 0,18 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB — 44 GHz to 50 GHz · CMC 0,24 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB — 9 kHz to 10 MHz · CMC 0,21 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB — 10 MHz to 45 MHz · CMC 0,21 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB — 45 MHz to 500 MHz · CMC 0,086 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB — 500 MHz to 2 GHz · CMC 0,11 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB — 2 GHz to 10 GHz · CMC 0,12 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB — 10 GHz to 20 GHz · CMC 0,14 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB — 20 GHz to 35 GHz · CMC 0,18 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB — 35 GHz to 44 GHz · CMC 0,19 CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB — 44 GHz to 50 GHz · CMC 0,25 CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB — 9 kHz to 10 MHz · CMC 5,2° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB — 10 MHz to 45 MHz · CMC 3,8° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB — 45 MHz to 500 MHz · CMC 3,8° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB — 500 MHz to 2 GHz · CMC 2,8° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB — 2 GHz to 10 GHz · CMC 2,9° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB — 10 GHz to 20 GHz · CMC 3,0° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB — 20 GHz to 35 GHz · CMC 3,2° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB — 35 GHz to 44 GHz · CMC 4,9° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB — 44 GHz to 50 GHz · CMC 14° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB — 9 kHz to 10 MHz · CMC 1,6° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB — 10 MHz to 45 MHz · CMC 1,5° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB — 45 MHz to 500 MHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB — 500 MHz to 2 GHz · CMC 0,79° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB — 2 GHz to 10 GHz · CMC 0,88° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB — 10 GHz to 20 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB — 20 GHz to 35 GHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB — 35 GHz to 44 GHz · CMC 1,5° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB — 44 GHz to 50 GHz · CMC 2,7° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB — 9 kHz to 10 MHz · CMC 0,94° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB — 10 MHz to 45 MHz · CMC 0,93° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB — 45 MHz to 500 MHz · CMC 0,57° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB — 500 MHz to 2 GHz · CMC 0,53° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB — 2 GHz to 10 GHz · CMC 0,62° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB — 10 GHz to 20 GHz · CMC 0,77° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB — 20 GHz to 35 GHz · CMC 0,97° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB — 35 GHz to 44 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB — 44 GHz to 50 GHz · CMC 1,5° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB — 9 kHz to 10 MHz · CMC 0,68° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB — 10 MHz to 45 MHz · CMC 0,68° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB — 45 MHz to 500 MHz · CMC 0,43° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB — 500 MHz to 2 GHz · CMC 0,44° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB — 2 GHz to 10 GHz · CMC 0,53° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB — 10 GHz to 20 GHz · CMC 0,68° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB — 20 GHz to 35 GHz · CMC 0,88° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB — 35 GHz to 44 GHz · CMC 0,90° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB — 44 GHz to 50 GHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB — 9 kHz to 10 MHz · CMC 0,44° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB — 10 MHz to 45 MHz · CMC 0,44° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB — 45 MHz to 500 MHz · CMC 0,37° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB — 500 MHz to 2 GHz · CMC 0,35° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB — 2 GHz to 10 GHz · CMC 0,44° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB — 10 GHz to 20 GHz · CMC 0,59° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB — 20 GHz to 35 GHz · CMC 0,81° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB — 35 GHz to 44 GHz · CMC 0,82° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB — 44 GHz to 50 GHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB — 9 kHz to 10 MHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB — 10 MHz to 45 MHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB — 45 MHz to 500 MHz · CMC 0,42° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB — 500 MHz to 2 GHz · CMC 0,59° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB — 2 GHz to 10 GHz · CMC 0,63° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB — 10 GHz to 20 GHz · CMC 0,77° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB — 20 GHz to 35 GHz · CMC 1,1° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB — 35 GHz to 44 GHz · CMC 1,2° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB — 44 GHz to 50 GHz · CMC 1,6° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB — 9 kHz to 10 MHz · CMC 1,4° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB — 10 MHz to 45 MHz · CMC 1,4° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB — 45 MHz to 500 MHz · CMC 0,50° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB — 500 MHz to 2 GHz · CMC 0,67° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB — 2 GHz to 10 GHz · CMC 0,70° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB — 10 GHz to 20 GHz · CMC 0,84° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB — 20 GHz to 35 GHz · CMC 1,2° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB — 35 GHz to 44 GHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB — 44 GHz to 50 GHz · CMC 1,7° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB — 9 kHz to 10 MHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB — 10 MHz to 45 MHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB — 45 MHz to 500 MHz · CMC 0,57° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB — 500 MHz to 2 GHz · CMC 0,74° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB — 2 GHz to 10 GHz · CMC 0.77° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB — 10 GHz to 20 GHz · CMC 0,92° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB — 20 GHz to 35 GHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB — 35 GHz to 44 GHz · CMC 1,3° CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB — 44 GHz to 50 GHz · CMC 1,7° RF electrical quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/34 LMEEiO/48 | |
| 55 | Time interval generators | Calibration — Time (time interval) 100 ps to 200 s · CMC 20 ps + 1 · 10⁻¹¹ · t 200 s to 10⁵ s · CMC 1 ns + 7 · 10⁻¹⁴ · t number of averaged periods not less than 10 — average period measurements · CMC 1 · 10⁻¹¹ · t Time (time interval) |
Internal procedure; At permanent location (S) | LMEEiO/7 LMEEiO/9 | |
| 56 | Time interval generators | Calibration — Time (time interval) 100 ps to 10⁵ s · CMC 20 ps + 1 · 10⁻¹⁰ · t number of averaged periods not less than 10 — average period measurements · CMC 1 · 10⁻¹⁰ · t Time (time interval) |
Internal procedure; Outside of permanent location (P) | LMEEiO/7 LMEEiO/9 | |
| 57 | Single-mode and multimode optical time-domain reflectometers | Calibration — Time (time interval) 400 ps to 100 ns · CMC 4,6 · 10⁻⁴ ns 100 ns to 1 µs · CMC 4,9 · 10⁻⁴ ns 1 µs to 10 µs · CMC 7,0 · 10⁻⁴ ns 10 µs to 100 µs · CMC 2,8 · 10⁻³ ns 100 µs to 1 ms · CMC 2,4 · 10⁻² ns 1 ms to 10 ms · CMC 2,3 · 10⁻¹ ns 10 ms to 100 ms · CMC 2,3 ns 100 ms to 1 s · CMC 23 ns Time (time interval) |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/21 | |
| 58 | Optical fibre path length standards Optical recirculating delay lines |
Calibration — Time (time interval) 400 ps to 100 ns · CMC 9,2 · 10⁻⁴ ns 100 ns to 1µs · CMC 9,8 · 10⁻⁴ ns 1 µs to 10 µs · CMC 14 · 10⁻⁴ ns 10 µs to 100 µs · CMC 5,6 · 10⁻³ ns 100 µs to 1 ms · CMC 5 · 10⁻² ns Time (time interval) |
Internal procedure; At permanent location (S) | LMEEiO/47 | |
| 59 | Electrical installation parameter meters (testers) RCD testers |
Calibration — Time (time interval) 10 ms to 5000 ms · CMC 0,02% + 0,25 ms Time (time interval) |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/35 | |
| 60 | Time interval meters | Calibration — Time (time interval) period of a sinusoidal signal — 100 ps to 100 µs · CMC 1·10⁻¹¹ · t for averaging time ≥1s period of a square wave signal; number of averaged periods not less than 10 — 10 ns to 10⁵ s · CMC 1 · 10⁻¹¹ · t for averaging time ≥1s pulse or square wave signal — 100 ps to 200 s · CMC 50 ps + 1 · 10⁻¹¹ · t pulse or square wave signal — 200 s to 10⁵ s · CMC 1 ns + 7 · 10⁻¹⁴ · t Time (time interval) |
Internal procedure; At permanent location (S) | LMEEiO/16 | |
| 61 | Time interval meters | Calibration — Time (time interval) period of a sinusoidal signal — 100 ps to 100 µs · CMC 1·10⁻¹⁰ · t for averaging time ≥1s period of a square wave signal; number of averaged periods not less than 10 — 10 ns to 10⁵ s · CMC 1 · 10⁻¹⁰ · t for averaging time ≥1s pulse or square wave signal — 100 ps to 10⁵ s · CMC 50 ps + 1 · 10⁻¹⁰ · t Time (time interval) |
Internal procedure; Outside of permanent location (P) | LMEEiO/16 | |
| 62 | Time interval meters | Calibration — Time (time interval) period of a sinusoidal signal — 100 ps to 100 µs · CMC 3·10⁻¹⁰ · t for averaging time ≥ 0,1s period of a sinusoidal signal — 100 ps to 100 µs · CMC 0,03 ns for averaging time < 0,1 s period of a sinusoidal signal — 100 µs to 1 ms · CMC 1·10⁻¹⁰ · t period of a sinusoidal signal — 1 ms to 10 ms · CMC 1·10⁻⁹ · t period of a sinusoidal signal — 10 ms to 1 s · CMC 5·10⁻⁸ · t period of a sinusoidal signal — 1 s to 10 s · CMC 1 · 10⁻⁷ · t Time (time interval) |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/16 | |
| 63 | Oscilloscopes Scopemeters |
Calibration — Time (time interval) 909,1 ps to 55 s · CMC 10 ps + 0,3 · 10⁻⁶ · t Time (time interval) |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/13 | |
| 64 | Line parameter and fault analysers | Calibration — Time (time interval) 5 ns to 1600 ns · CMC 10 % Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/42 | |
| 65 | Phase time Time interval error meters (TIE) Phase time comparators |
Calibration — Time (time interval) 2,048 MHz — 1 ns to 100 ms · CMC 0,1 ns + 5 · 10⁻¹⁰ TIE 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz — 1 ns to 1 s · CMC 0,1 ns + 5 · 10⁻¹⁰ · x 1 Hz — 1 ns to 1 s · CMC 0,5 ns Time (time interval) |
Internal procedure; At permanent location (S) | LMEEiO/17 | |
| 66 | Phase time fluctuation (jitter) meters included in receivers of PDH/SDH analysers/testers (peak-to-peak signal values) | Calibration — Time (time interval) For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 2,048 Mb/s — 0 UI to 21,751 UI · CMC 0,003 UI For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 8,448 Mb/s — 0 UI to 21,751 UI · CMC 0,003 UI For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 34,648 Mb/s — 0 UI to 21,751 UI · CMC 0,003 UI For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 139,264 Mb/s — 0 UI to 21,751 UI · CMC 0,003 UI For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 155,520 Mb/s — 0 UI to 21,751 UI · CMC 0,03 UI For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 622,080 Mb/s — 0 UI to 256 UI · CMC 8 % of measured value + 0,02 UI For phase time fluctuation frequencies 100 Hz, 1 kHz, 10kHz, 100 kHz ranges and bit rates as above · CMC 0,003 UI do 0,03 UI For phase time fluctuation frequencies 2 Hz to 20 MHz, ranges and bit rates as above · CMC (8 % do 15 %) w. mierz 0,02 UI Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/30 LMEEiO/27 | |
| 67 | Phase time fluctuation (jitter) generators included in transmitters of PDH/SDH analysers/testers (peak-to-peak signal values) | Calibration — Time (time interval) For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 2,048 Mb/s — 0 UI to 21,751 UI · CMC 0,002 UI For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 8,448 Mb/s — 0 UI to 21,751 UI · CMC 0,002 UI For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 34,648 Mb/s — 0 UI to 21,751 UI · CMC 0,002 UI For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 139,264 Mb/s — 0 UI to 21,751 UI · CMC 0,002 UI For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 155,520 Mb/s — 0 UI to 21,751 UI · CMC 0,02 UI For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 622,080 Mb/s — 0 UI to 800 UI · CMC 5 % of measured value + 0,07 UI For phase time fluctuation frequencies 100 Hz, 1 kHz, 10 kHz, 100 kHz ranges and bit rates as above · CMC 0,002 UI do 0,02 UI For phase time fluctuation frequencies 2 Hz to 20 MHz, ranges and bit rates as above · CMC (5 % do 19 %) w. mierz 0,024 UI do 0,2 UI Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/30 LMEEiO/27 | |
| 68 | High-stability generators, Quartz and non-quartz generators (frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire) |
Calibration — Frequency 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz · CMC 5 · 10⁻¹⁴ · f at averaging time 7d 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz · CMC 5 · 10⁻¹³ · f at averaging time 1 h 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz · CMC 1 · 10⁻¹² · f at averaging time 1000 s 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz · CMC 1 · 10⁻¹¹ · f at averaging time 100 s 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz · CMC 7 · 10⁻¹⁴ · f at averaging time 1d (provided simultaneous remote comparisons with the national measurement standard of GUM) Frequency |
Internal procedure; At permanent location (S) | LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44 | |
| 69 | High-stability generators, Quartz and non-quartz generators (frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire) |
Calibration — Frequency 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz · CMC 1 · 10⁻¹⁰ · f at averaging time 1d 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz · CMC 1 · 10⁻¹⁰ · f at averaging time 1 h 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz · CMC 1·10⁻¹⁰ · f at averaging time 1000 s 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz · CMC 1 · 10⁻¹⁰ · f at averaging time 100 s Frequency |
Internal procedure; Outside of permanent location (P) | LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44 | |
| 70 | High-stability generators, Quartz and non-quartz generators (frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire) |
Calibration — Frequency square wave signal (period measurements in the range 0,001 Hz to 0,1 Hz) — 0,001 Hz to 3 GHz · CMC 1 · 10⁻¹¹ · f at averaging time ≥ 1 s sinusoidal signal — 10 kHz to 40 GHz · CMC 1 · 10⁻¹¹ · f at averaging time ≥ 1 s Frequency |
Internal procedure; At permanent location (S) | LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44 | |
| 71 | High-stability generators, Quartz and non-quartz generators (frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire) |
Calibration — Frequency square wave signal (period measurements in the range 0,001 Hz to 0,1 Hz) — 0,001 Hz to 3 GHz · CMC 1 · 10⁻¹⁰ · f at averaging time ≥ 1 s sinusoidal signal — 10 kHz to 40 GHz · CMC 1 · 10⁻¹⁰ · f at averaging time ≥ 1 s Frequency |
Internal procedure; Outside of permanent location (P) | LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44 | |
| 72 | High-stability generators, Quartz and non-quartz generators (frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire) |
Calibration — Frequency 1 kHz to 10 kHz · CMC 1 · 10⁻¹⁰ · f 100 Hz to 1 kHz · CMC 1 · 10⁻⁹ · f 1 Hz to 100 Hz · CMC 5 · 10⁻⁸ · f 0,1 Hz to 1 Hz · CMC 1 · 10⁻⁷ · f Frequency |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44 | |
| 73 | Transmitters included in digital transmission analysers | Calibration — Frequency 8 kHz to 3 GHz · CMC 1 · 10⁻¹⁰ · f at averaging time ≥ 1 s Frequency |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/7 LMEEiO/27 | |
| 74 | Digital frequency meters (including frequency meters built into e.g. power meters) | Calibration — Frequency square wave signal — 0,001 Hz to 100 MHz · CMC 3 · 10⁻¹⁰ · f at averaging time ≥ 0,1 s sinusoidal signal — 10 kHz to 40 GHz · CMC 3 · 10⁻¹⁰ · f at averaging time ≥ 0,1 s sinusoidal signal — 1 kHz to 10 kHz · CMC 1 · 10⁻¹⁰ · f sinusoidal signal — 100 Hz to 1 kHz · CMC 1 · 10⁻⁹ · f sinusoidal signal — 1 Hz to 100 Hz · CMC 5 · 10⁻⁸ · f sinusoidal signal — 0,1 Hz to 1 Hz · CMC 1 · 10⁻⁷ · f Frequency |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/16 LMEEiO/31 | |
| 75 | Digital frequency meters (including frequency meters built into e.g. power meters) | Calibration — Frequency square wave signal — 0,001 Hz to 100 MHz · CMC 1 · 10⁻¹¹ · f at averaging time ≥ 1 s sinusoidal signal — 10 kHz to 40 GHz · CMC 1 · 10⁻¹¹ · f at averaging time ≥ 1 s Frequency |
Internal procedure; At permanent location (S) | LMEEiO/16 LMEEiO/31 | |
| 76 | Digital frequency meters (including frequency meters built into e.g. power meters) | Calibration — Frequency square wave signal — 0,001 Hz to 100 MHz · CMC 1 · 10⁻¹⁰ · f at averaging time ≥ 1 s sinusoidal signal — 10 kHz to 40 GHz · CMC 1 · 10⁻¹⁰ · f at averaging time ≥ 1 s Frequency |
Internal procedure; Outside of permanent location (P) | LMEEiO/16 LMEEiO/31 | |
| 77 | Digital frequency meters forming part of other measuring instruments, e.g. universal meters | Calibration — Frequency 0,1 Hz to 10 MHz · CMC 0,6 · Δ₁ but not better than 0,001 % Frequency |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/2 | |
| 78 | Frequency comparators - relative frequency deviation |
Calibration — Frequency f = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz — 10⁻¹² to 10⁻⁷ Hz/Hz · CMC 1 · 10⁻¹³ Hz/Hz at averaging time ≥ 1 d f = 0,1 Hz to 1,2 GHz — 10⁻¹⁰ to 10⁻⁷ Hz/Hz · CMC 2 · 10⁻¹² Hz/Hz at averaging time 1000 s f = 0,1 Hz to 1,2 GHz — 10⁻¹⁰ to 10⁻⁷ Hz/Hz · CMC 1 · 10⁻¹¹ Hz/Hz at averaging time 10 s f = 0,1 Hz to 1,2 GHz — 10⁻¹⁰ to 10⁻⁷ Hz/Hz · CMC 5 · 10⁻¹¹ Hz/Hz at averaging time 1 s Frequency |
Internal procedure; At permanent location (S) | LMEEiO/18 | |
| 79 | Oscilloscopes - internal AC reference sources |
Calibration — Frequency 100 Hz to 10 kHz · CMC 0,4 · 10⁻⁶ · f Frequency |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/13 | |
| 80 | Sinusoidal measuring signal sources (generators) Calibrators |
Calibration — Frequency 10 Hz to 100 Hz · CMC 5·10⁻⁶ · f 100 Hz to 100 MHz · CMC 5·10⁻⁸ · f Frequency |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/3LMEEiO/10 LMEEiO/42 | |
| 81 | Sinusoidal measuring signal meters (meters) | Calibration — Frequency 10 Hz to 50 MHz · CMC 0,6 · Δ₂ Frequency |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/11 LMEEiO/42 | |
| 82 | Calibrators RLC meters (bridges) Impedance meters (bridges) |
Calibration — Frequency 10 Hz to 10 MHz · CMC 0,001 % Frequency |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/3 LMEEiO/5 | |
| 83 | Optical radiation sources (modulated and unmodulated) Attenuation measurement sets |
Calibration — Frequency 1 Hz to 2,5 GHz · CMC 3 · 10⁻³ Hz Frequency |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/22 | |
| 84 | Return loss meters | Calibration — Frequency 10 Hz do 100 Hz · CMC 2,3 · 10⁻⁶ Hz 100 Hz do 1 kHz · CMC 2,3 · 10⁻⁵ Hz 1 kHz do 10 kHz · CMC 2,3 · 10⁻⁴ Hz 10 kHz do 100 kHz · CMC 2,4 · 10⁻³ Hz 100 kHz do 10 MHz · CMC 7,0 · 10⁻¹ Hz 10 MHz to 100 MHz · CMC 49 Hz 100 MHz do 1 GHz · CMC 46 · 10² Hz 1 GHz do 2,5 GHz · CMC 46·10⁴ Hz Frequency |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/26 | |
| 85 | Frequency meters and generators of PCM signal analysers |
Calibration — Frequency for level -10 dBm — 20 Hz to 100 Hz · CMC 2,5 · 10⁻⁵ · f for level -10 dBm — 100 Hz to 3403 Hz · CMC 5 · 10⁻⁶ · f Frequency |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/37 | |
| 86 | Digital transmission analysers | Calibration — Frequency 1,544 MHz to 28,6 GHz · CMC 1 · 10⁻⁹ · f Frequency |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/27 LMEEiO/37 | |
| 87 | Digital transmission analysers for data transmission interfaces | Calibration — Frequency 64 kHz to 2048 kHz · CMC 1 · 10⁻⁸ · f Frequency |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/38 | |
| 88 | Spectrum analysers Network analysers Antenna and cable system analysers Measuring receivers |
Calibration — Frequency 9 kHz to 40 GHz · CMC 2 · 10⁻¹⁰ · f at averaging time 1 s 9 kHz to 40 GHz · CMC 4 · 10⁻¹¹ · f at averaging time 0,1 s Frequency |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44 | |
| 89 | Line parameter and fault analysers | Calibration — Frequency 20 kHz to 1200 kHz · CMC 0,001 % Frequency |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/42 | |
| 90 | Power quality analyser - frequency fluctuations |
Calibration — Frequency 45 Hz to 55 Hz · CMC 0,2 % Frequency |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/50 | |
| 91 | Hygrometers Thermohygrometers |
Calibration — Relative humidity temperature range 10 °C to 20 °C — 25 %rh to 95 %rh · CMC 0,9 %rh temperature range 20 °C to 40 °C — 10 %rh to 95 %rh · CMC 1,0 %rh temperature range 40 °C to 60 °C — 10 %rh to 90 %rh · CMC 1,1 %rh Relative humidity |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/54 LMEEiO/55 | |
| 92 | Hygrometers Thermohygrometers |
Calibration — Relative humidity temperature range 60 °C to 80 °C — 10 %rh to 50 %rh · CMC 1,6 %rh Relative humidity |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/54 LMEEiO/55 | |
| 93 | Climatic chambers | Calibration — Relative humidity temperature range 10 °C to 20 °C — 10 %rh to 95 %rh · CMC 2,6 %rh temperature range 20 °C to 40 °C — 10 %rh to 95 %rh · CMC 2,6 %rh temperature range 40 °C to 60 °C — 10 %rh to 95 %rh · CMC 2,7 %rh temperature range 60 °C to 80 °C — 10 %rh to 50 %rh · CMC 2,7 %rh Relative humidity |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/54 LMEEiO/55 | |
| 94 | Optical power (power level) meters Attenuation measurement sets Optical spectrum analysers Wavelength meters Return loss meters - optical radiation power (power level) |
Calibration — Optoelectronic quantities wavelength 850 nm, 1260 nm to 1360 nm, 1480 nm to 1680 nm — 100 pW to 150 µW · CMC 1,26 % wavelength 850 nm, 1260 nm to 1360 nm, 1480 nm to 1680 nm — -70 dBm to -8 dBm · CMC 0,054 dB Optoelectronic quantities |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/21, LMEEiO/22, LMEEiO/24, LMEEiO/26, LMEEiO/ 27 LMEEiO/29, LMEEiO/36 based on PN-EN IEC 61315:2019-10 IEC 62129-1:2016 | |
| 95 | Optical radiation sources Attenuation measurement sets Return loss (reflectance) meters Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers Multimode optical time-domain reflectometers Transmitters included in PDH/SDH analysers/testers - optical radiation power (power level) |
Calibration — Optoelectronic quantities wavelength 350 nm to 400 nm — 100 pW to 500 mW · CMC 7% wavelength 350 nm to 400 nm — -70 dBm to 25 dBm · CMC 0,3 dB Optoelectronic quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/21, LMEEiO/22 LMEEiO/24, LMEEiO/26, LMEEiO/27 based on PN-EN-61280-1-1:2013-10 | |
| 96 | Optical radiation sources Attenuation measurement sets Return loss (reflectance) meters Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers Multimode optical time-domain reflectometers Transmitters included in PDH/SDH analysers/testers - optical radiation power (power level) |
Calibration — Optoelectronic quantities wavelength 450 nm to 1700 nm — 100 pW to 500 mW · CMC 4,0 % wavelength 450 nm to 1700 nm — -70 dBm to 25 dBm · CMC 0,17 dB Optoelectronic quantities |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/21, LMEEiO/22 LMEEiO/24, LMEEiO/26, LMEEiO/27 based on PN-EN-61280-1-1:2013-10 | |
| 97 | Optical power (power level) meters Attenuation measurement sets Optical spectrum analysers Wavelength meters Return loss meters - scale non-linearity in optical radiation power (power level) measurement |
Calibration — Optoelectronic quantities wavelength 850 nm 1260 nm to 1360 nm 1480 nm to 1680 nm — 100 pW to 1 mW · CMC 0,15% wavelength 850 nm 1260 nm to 1360 nm 1480 nm to 1680 nm — -70 dBm to 0 dBm · CMC 0,007 dB Optoelectronic quantities |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/21, LMEEiO/22, LMEEiO/24, LMEEiO/26, LMEEiO/ 27 LMEEiO/29, LMEEiO/36 based on PN-EN IEC 61315:2019-10 IEC 62129-1:2016 | |
| 98 | Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers - optical fibre length |
Calibration — Optoelectronic quantities wavelength 1310 nm — up to 25 km · CMC 0,3 m wavelength 1383 nm — up to 25 km · CMC 0,3 m wavelength 1490 nm — up to 25 km · CMC 0,3 m wavelength 1550 nm — up to 25 km · CMC 0,3 m wavelength 1625 nm — up to 25 km · CMC 0,3 m wavelength 1650 nm — up to 25 km · CMC 0,3 m Optoelectronic quantities |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/21 based on PN-EN 61746-1:2011 | |
| 99 | Multimode optical time-domain reflectometers - optical fibre length |
Calibration — Optoelectronic quantities wavelength 850 nm — up to 5 km · CMC 1,4 m wavelength 1300 nm — up to 5 km · CMC 0,4 m Optoelectronic quantities |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/21 based on PN-EN 61746-2:2011 | |
| 100 | Optical fibre path length standards - optical fibre length |
Calibration — Optoelectronic quantities 0 km to 50 km · CMC 0,15 m Optoelectronic quantities |
Internal procedure; At permanent location (S) | LMEEiO/47 based on PN-EN 61746-1:2011 | |
| 101 | Optical attenuators Optical couplers Optical switches Fibre-optic optoelectronic objects - attenuation |
Calibration — Optoelectronic quantities wavelengths: 850 nm; 1260 nm to 1360 nm 1480 nm to 1680 nm — 0 dB to 70 dB · CMC 0,039 dB wavelengths: 850 nm; 1260 nm to 1360 nm 1480 nm to 1680 nm — 0 dB to 70 dB · CMC 0,9 % Optoelectronic quantities |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/23 based on PN-EN-61280-4-2:2014 Annex C | |
| 102 | Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers - attenuation coefficient |
Calibration — Optoelectronic quantities wavelength 1310 nm — 0,326 dB/km to 0,334 dB/km · CMC 0,008 dB/km wavelength 1550 nm — 0,186 dB/km to 0,194 dB/km · CMC 0,008 dB/km Optoelectronic quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/21 | |
| 103 | Optical time-domain reflectometers (OTDR) Multimode optical time-domain reflectometers - attenuation coefficient |
Calibration — Optoelectronic quantities wavelength 850 nm — 2,566 dB/km to 2,718 dB/km · CMC 0,053 dB/km wavelength 1300 nm — 0,470 dB/km to 0,526 dB/km · CMC 0,021 dB/km Optoelectronic quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/21 | |
| 104 | Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers - attenuation scale linearity (attenuation scale deviation) |
Calibration — Optoelectronic quantities wavelength range 1310 nm; wavelength range 1550 nm · CMC 0,01 dB/dB Optoelectronic quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/21 | |
| 105 | Multimode optical time-domain reflectometers - attenuation scale linearity (attenuation scale deviation) |
Calibration — Optoelectronic quantities wavelength range 850 nm; wavelength range 1300 nm · CMC 0,02 dB/dB Optoelectronic quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/21 | |
| 106 | Return loss (reflectance) meters – return loss (reflectance) |
Calibration — Optoelectronic quantities wavelength: 850 nm, 1300 nm, 1310 nm, 1550 nm — 3,5 dB to 50 dB · CMC 0,32 dB wavelength: 850 nm, 1300 nm, 1310 nm, 1550 nm — 50 dB to 65 dB · CMC 0,66 dB Optoelectronic quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/26 | |
| 107 | Fibre-optic optoelectronic objects - return loss (reflectance) |
Calibration — Optoelectronic quantities 5 dB to 50 dB · CMC 0,38 dB 50 dB to 68 dB · CMC 0,48 dB Optoelectronic quantities |
Direct method. Measurement according to the method implemented by instruments based on the OCWR technique and described in PN-EN-61280-4-2:2014-11 Annex E and Annex F; At permanent location (S) and outside of it (P) | LMEEiO/25 | |
| 108 | Single-mode optical time-domain reflectometers - return loss (reflectance) |
Calibration — Optoelectronic quantities 5 dB to 70 dB · CMC 1 dB Optoelectronic quantities |
Direct method; At permanent location (S) and outside of it (P) | LMEEiO/21 | |
| 109 | Return loss (reflectance) meters Optical spectrum analysers Wavelength meters Optical switches Fibre-optic optoelectronic objects Optical couplers Optical attenuators - polarization dependent loss (PDL), polarization dependence of power readings |
Calibration — Optoelectronic quantities wavelength 1250 nm to 1600 nm — 0 dB to 62 dB · CMC 0,23 % wavelength 1250 nm to 1600 nm — 0 dB to 62 dB · CMC 0,01 dB Optoelectronic quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/21, LMEEiO/26, LMEEiO/29, LMEEiO/36, based on PN-EN 61315:2019-10 and IEC 62129-1:2016 | |
| 110 | Modulated and unmodulated optical radiation sources Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers Multimode optical time-domain reflectometers Return loss (reflectance) meters Attenuation measurement sets Optical transmitters included in digital transmission analysers - optical radiation wavelength |
Calibration — Optoelectronic quantities 350 nm to 700 nm · CMC 0,5 nm 700 nm to 1700 nm · CMC 0,2 pm 1700 nm to 1750 nm · CMC 0,5 nm Optoelectronic quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/21, LMEEiO 22, LMEEiO/26, LMEEiO/27, LMEEiO/29, LMEEiO/36 based on PN-EN-61280-1-3:2022-04 IEC-62522:2014 | |
| 111 | Optical spectrum analysers Wavelength meters - optical radiation wavelength |
Calibration — Optoelectronic quantities 1510 nm to 1540 nm · CMC 0,3 pm 1255 nm to 1351 nm · CMC 0,3 pm 1310 nm · CMC 0,3 pm 1495 nm to 1640 nm · CMC 0,3 pm 1532,8279 nm · CMC 0,2 pm 1532,8329 nm · CMC 0,2 pm 1532,8304 nm · CMC 0,3 pm Optoelectronic quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/21, LMEEiO 22, LMEEiO/26, LMEEiO/27, LMEEiO/29, LMEEiO/36 based on IEC 62129-1:2016 PN-EN-62129-2:2012 | |
| 112 | Modulated and unmodulated optical radiation sources Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers Multimode optical time-domain reflectometers Return loss (reflectance) meters Attenuation measurement sets Optical transmitters included in PDH/SDH analysers/testers - side mode suppression ratio (SMSR) |
Calibration — Optoelectronic quantities wavelengths 350 nm to 1750 nm — 1 dB to 70 dB · CMC 0,49 dB Optoelectronic quantities |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | LMEEiO/21, LMEEiO/22, LMEEiO/26, LMEEiO/27 based on PN-EN-61280-1-3:2022-04 | |
| 113 | Bourdon tube pressure gauges Electronic pressure gauges |
Calibration — Pressure 0 MPa to 0,1 MPa · CMC 0,00009 MPa 0,1 MPa to 1 MPa · CMC 0,0006 MPa 1 MPa to 60 MPa · CMC 0,03 MPa Pressure |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/56 based on EURAMET cg17v4.1 | |
| 114 | Noble metal thermocouples Base metal thermocouples |
Calibration — Temperature (electrical thermometry) -80 °C to 250 °C · CMC 0,5 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) | LMEEiO/51 based on EURAMET cg-8 v. 3.1 | |
| 115 | Resistance thermometer sensors | Calibration — Temperature (electrical thermometry) -80 °C do -50 °C · CMC 0,09 °C -50 °C do -30 °C · CMC 0,06 °C -30 °C to 50 °C · CMC 0,02 °C 50 °C do 250 °C · CMC 0,04 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) | LMEEiO/51 | |
| 116 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) |
Calibration — Temperature (electrical thermometry) -80 °C to -50 °C · CMC 0,15 °C -50 °C to -30 °C · CMC 0,10 °C -30 °C to 140 °C · CMC 0,10 °C Temperature (electrical thermometry) |
Internal procedure; Performed in a temperature calibrator; At permanent location (S) and outside of it (P) | LMEEiO/51 | |
| 117 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) |
Calibration — Temperature (electrical thermometry) -30 °C to 50 °C · CMC 0,02 °C 50 °C do 250 °C · CMC 0,04 °C Temperature (electrical thermometry) |
Internal procedure; Performed in a liquid bath; At permanent location (S) | LMEEiO/51 | |
| 118 | Temperature calibrators | Calibration — Temperature (electrical thermometry) -80 °C to 400 °C · CMC 0,7 °C 400 °C to 1084 °C · CMC 1,0 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/52 based on EURAMET cg-13 v. 4.0 | |
| 119 | Liquid thermostats | Calibration — Temperature (electrical thermometry) -30 °C to 250 °C · CMC 0,06 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/52 | |
| 120 | Thermostatic chambers Climatic chambers |
Calibration — Temperature (electrical thermometry) -70 °C to -50 °C · CMC 0,3 °C -50 °C to 180 °C · CMC 0,2 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) and outside of it (P) | LMEEiO/52 based on EURAMET cg-20 v. 5.0 | |
Reference standards (66)
EURAMET cg-13 v. 4.0
EURAMET cg-15 v. 3.0
EURAMET cg-20 v. 5.0
EURAMET cg-7 v. 1.0
EURAMET cg-8 v. 3.1
EURAMET cg17v4.1
IEC 62129-1:2016
IEC-62522:2014
LMEEiO 22
LMEEiO/ 27
LMEEiO/10
LMEEiO/11
LMEEiO/13
LMEEiO/14
LMEEiO/16
LMEEiO/17
LMEEiO/18
LMEEiO/2
LMEEiO/21
LMEEiO/22
LMEEiO/23
LMEEiO/24
LMEEiO/25
LMEEiO/26
LMEEiO/27
LMEEiO/28
LMEEiO/29
LMEEiO/3
LMEEiO/30
LMEEiO/31
LMEEiO/32
LMEEiO/33
LMEEiO/34
LMEEiO/35
LMEEiO/36
LMEEiO/37
LMEEiO/38
LMEEiO/39
LMEEiO/4
LMEEiO/40
LMEEiO/41
LMEEiO/42
LMEEiO/43
LMEEiO/44
LMEEiO/45
LMEEiO/46
LMEEiO/47
LMEEiO/48
LMEEiO/5
LMEEiO/50
LMEEiO/51
LMEEiO/52
LMEEiO/53
LMEEiO/54
LMEEiO/55
LMEEiO/56
LMEEiO/7
LMEEiO/9
PN-EN 61315:2019-10
PN-EN 61746-1:2011
PN-EN 61746-2:2011
PN-EN IEC 61315:2019-10
PN-EN-61280-1-1:2013-10
PN-EN-61280-1-3:2022-04
PN-EN-61280-4-2:2014
PN-EN-62129-2:2012