{"lab":{"_id":"6afad80b8989a133b76447c7","accr_number":"AP 015","country":"PL","imported_at":"2026-11-16T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Szachowa 1, 04-894 Warszawa","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"18.10.2019","city":"Warszawa","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. The value of the uncertainty covered by the CMC expressed as a percentage is the relative measurement uncertainty and refers to the percentage share of the value of the measurand.","cycle_from":"21.12.2023","cycle_to":"20.12.2027","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"7.01","pl":"Napięcie DC","en":"DC voltage","de":"DC-Spannung","zh":"直流电压","cs":"Napětí DC"},{"codes":"7.02","pl":"Prąd DC","en":"DC current","de":"DC-Strom","zh":"直流电流","cs":"Proud DC"},{"codes":"7.03","pl":"Napięcie AC","en":"AC voltage","de":"AC-Spannung","zh":"交流电压","cs":"Napětí AC"},{"codes":"7.04","pl":"Prąd AC","en":"AC current","de":"AC-Strom","zh":"交流电流","cs":"Proud AC"},{"codes":"7.05","pl":"Rezystancja DC","en":"DC resistance","de":"DC-Widerstand","zh":"直流电阻","cs":"Odpor DC"},{"codes":"7.06","pl":"Rezystancja AC","en":"AC resistance","de":"AC-Widerstand","zh":"交流电阻","cs":"Odpor AC"},{"codes":"7.07","pl":"Impedancja","en":"Impedance","de":"Impedanz","zh":"阻抗","cs":"Impedance"},{"codes":"7.08","pl":"Indukcyjność","en":"Inductance","de":"Induktivität","zh":"电感","cs":"Indukčnost"},{"codes":"7.09","pl":"Pojemność","en":"Capacitance","de":"Kapazität","zh":"容量","cs":"Objem"},{"codes":"7.10","pl":"Kąt przesunięcia fazowego","en":"Phase angle","de":"Phasenverschiebungswinkel","zh":"相位角","cs":"Fázový úhel"},{"codes":"7.11","pl":"Energia","en":"Energy","de":"Energie","zh":"能量","cs":"Energie"},{"codes":"7.12","pl":"Moc DC","en":"DC power","de":"DC-Leistung","zh":"直流功率","cs":"Stejnosměrný výkon"},{"codes":"7.13","pl":"Moc AC","en":"AC power","de":"AC-Leistung","zh":"交流功率","cs":"Výkon AC"},{"codes":"7.15","pl":"Elektryczna symulacja wielkości","en":"Electrical simulation of quantities","de":"Elektrische Simulation von Größen","zh":"量值的电模拟","cs":"Elektrická simulace veličin"},{"codes":"8.01","pl":"Wielkości elektryczne w.cz.","en":"RF electrical quantities","de":"Elektrische HF-Größen","zh":"射频电学量","cs":"Vysokofrekvenční elektrické veličiny"},{"codes":"10.01","pl":"Czas (przedział czasu)","en":"Time (time interval)","de":"Zeit (Zeitintervall)","zh":"时间（时间间隔）","cs":"Čas (časový interval)"},{"codes":"10.02","pl":"Częstotliwość","en":"Frequency","de":"Frequenz","zh":"频率","cs":"Frekvence"},{"codes":"14.02","pl":"Wilgotność względna","en":"Relative humidity","de":"Relative Feuchte","zh":"相对湿度","cs":"Relativní vlhkost"},{"codes":"16.01","pl":"Wielkości optoelektroniczne","en":"Optoelectronic quantities","de":"Optoelektronische Größen","zh":"光电量","cs":"Optoelektronické veličiny"},{"codes":"17.01","pl":"Ciśnienie","en":"Pressure","de":"Druck","zh":"压力","cs":"Tlak"},{"codes":"19.01","pl":"Temperatura (termometria elektryczna)","en":"Temperature (electrical thermometry)","de":"Temperatur (elektrische Thermometrie)","zh":"温度（电测温）","cs":"Teplota (elektrická termometrie)"}],"has_en":true,"has_zh":true,"issue":{"no":"23","date":"09.12.2025"},"issue_date":"09.12.2025","issue_number":"23","lab_division":"Laboratorium Metrologii Elektrycznej, Elektronicznej i Optoelektronicznej","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[21.1951879,52.1725492]},"map_coord":[52.1725492,21.1951879],"map_geo":"nominatim-street","methods_count":120,"name":"Instytut Łączności - Państwowy Instytut Badawczy","parse_date":"2026-11-16T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-16T12:00:00.000Z","pdf_files":["AP_015.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: Napięcie DC, Prąd DC, Napięcie AC, Prąd AC, Rezystancja DC, Rezystancja AC, Impedancja, Indukcyjność, Pojemność, Kąt przesunięcia fazowego, Energia, Moc DC, Moc AC, Elektryczna symulacja wielkości, Wielkości elektryczne w.cz., Czas (przedział czasu), Częstotliwość, Wilgotność względna, Wielkości optoelektroniczne, Ciśnienie, Temperatura (termometria elektryczna). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"instytut łączności - państwowy instytut badawczy laboratorium metrologii elektrycznej, elektronicznej i optoelektronicznej ul. szachowa 1, 04-894 warszawa laboratorium wzorcujące. wielkości mierzone: napięcie dc, prąd dc, napięcie ac, prąd ac, rezystancja dc, rezystancja ac, impedancja, indukcyjność, pojemność, kąt przesunięcia fazowego, energia, moc dc, moc ac, elektryczna symulacja wielkości, wielkości elektryczne w.cz., czas (przedział czasu), częstotliwość, wilgotność względna, wielkości optoelektroniczne, ciśnienie, temperatura (termometria elektryczna). w stałej lokalizacji (s) i/lub poza nią (p). ap 015 ap015 laboratorium wzorcujące wzorcowanie kalibracja dc voltage dc current ac voltage ac current dc resistance ac resistance impedance inductance capacitance phase angle energy dc power ac power electrical simulation of quantities rf electrical quantities time (time interval) frequency relative humidity optoelectronic quantities pressure temperature (electrical thermometry) instytut lacznosci - panstwowy instytut badawczy laboratorium metrologii elektrycznej, elektronicznej i optoelektronicznej ul. szachowa 1, 04-894 warszawa laboratorium wzorcujace. wielkosci mierzone: napiecie dc, prad dc, napiecie ac, prad ac, rezystancja dc, rezystancja ac, impedancja, indukcyjnosc, pojemnosc, kat przesuniecia fazowego, energia, moc dc, moc ac, elektryczna symulacja wielkosci, wielkosci elektryczne w.cz., czas (przedzial czasu), czestotliwosc, wilgotnosc wzgledna, wielkosci optoelektroniczne, cisnienie, temperatura (termometria elektryczna). w stalej lokalizacji (s) i/lub poza nia (p). ap 015 ap015 laboratorium wzorcujace wzorcowanie kalibracja dc voltage dc current ac voltage ac current dc resistance ac resistance impedance inductance capacitance phase angle energy dc power ac power electrical simulation of quantities rf electrical quantities time (time interval) frequency relative humidity optoelectronic quantities pressure temperature (electrical thermometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20015,podmiot.html","source_pdf_sha256":"104d4119911bfd0d23952ce12bd815e308d17d59d86d7435280c47400c265023","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/16/b4789bc84c930d33b15b43f56d9a91b2/AP%20015.pdf","status":"active","updated_at":"2026-11-16T12:00:00.000Z","valid_from":"21-12-1999","valid_until":"20-12-2027","website":"www.gov.pl/web/instytut-lacznosci/lmeeio","lab_division_en":"Laboratory of Electrical, Electronic and Optoelectronic Metrology","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"lab_division_de":"Labor für elektrische, elektronische und optoelektronische Metrologie","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","lab_division_zh":"电学、电子与光电计量实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"lab_division_cs":"Laboratoř elektrické, elektronické a optoelektronické metrologie","pelny_cs":true},"methods":[{"_id":"67e3687fe352ba03142c3596","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Kalibratory\nŹródła napięcia stałego\nKarty pomiarowe\nZasilacze\nPróbniki przebicia\nTestery bezpieczeństwa elektrycznego\nMostki","test_object_en":"Calibrators\nDC voltage sources\nData acquisition cards\nPower supplies\nBreakdown testers\nElectrical safety testers\nBridges","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0 mV do 5 mV","cmc":"6·10⁻⁵ · U + 0,03 µV"},{"name":"","range":"5 mV do 10 mV","cmc":"7·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"10 mV do 200 mV","cmc":"6·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"0,2 V do 2 V","cmc":"4·10⁻⁶ · U + 0,5 µV"},{"name":"","range":"2 V do 20 V","cmc":"4·10⁻⁶ · U + 5 µV"},{"name":"","range":"20 V do 200 V","cmc":"5·10⁻⁶ · U + 0,03 mV"},{"name":"","range":"200 V do 1000 V","cmc":"0,0007 %"},{"name":"","range":"1 kV do 10 kV","cmc":"0,05 %"}],"parameters_en":[{"name":"","range":"0 mV to 5 mV","cmc":"6·10⁻⁵ · U + 0,03 µV"},{"name":"","range":"5 mV to 10 mV","cmc":"7·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"10 mV to 200 mV","cmc":"6·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"0,2 V to 2 V","cmc":"4·10⁻⁶ · U + 0,5 µV"},{"name":"","range":"2 V to 20 V","cmc":"4·10⁻⁶ · U + 5 µV"},{"name":"","range":"20 V to 200 V","cmc":"5·10⁻⁶ · U + 0,03 mV"},{"name":"","range":"200 V to 1000 V","cmc":"0,0007 %"},{"name":"","range":"1 kV to 10 kV","cmc":"0,05 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0 mV do 5 mV CMC 6·10⁻⁵ · U + 0,03 µV\n5 mV do 10 mV CMC 7·10⁻⁶ · U + 0,1 µV\n10 mV do 200 mV CMC 6·10⁻⁶ · U + 0,1 µV\n0,2 V do 2 V CMC 4·10⁻⁶ · U + 0,5 µV\n2 V do 20 V CMC 4·10⁻⁶ · U + 5 µV\n20 V do 200 V CMC 5·10⁻⁶ · U + 0,03 mV\n200 V do 1000 V CMC 0,0007 %\n1 kV do 10 kV CMC 0,05 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/3\nLMEEiO/5\nLMEEiO/28\nLMEEiO/35","norm_bases":["LMEEiO/3","LMEEiO/5","LMEEiO/28","LMEEiO/35"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured value (V)","search_text":"Kalibratory\nŹródła napięcia stałego\nKarty pomiarowe\nZasilacze\nPróbniki przebicia\nTestery bezpieczeństwa elektrycznego\nMostki Wzorcowanie — Napięcie DC\nZakres:\n0 mV do 5 mV CMC 6·10⁻⁵ · U + 0,03 µV\n5 mV do 10 mV CMC 7·10⁻⁶ · U + 0,1 µV\n10 mV do 200 mV CMC 6·10⁻⁶ · U + 0,1 µV\n0,2 V do 2 V CMC 4·10⁻⁶ · U + 0,5 µV\n2 V do 20 V CMC 4·10⁻⁶ · U + 5 µV\n20 V do 200 V CMC 5·10⁻⁶ · U + 0,03 mV\n200 V do 1000 V CMC 0,0007 %\n1 kV do 10 kV CMC 0,05 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/3\nLMEEiO/5\nLMEEiO/28\nLMEEiO/35 Kalibratory\nZrodla napiecia stalego\nKarty pomiarowe\nZasilacze\nProbniki przebicia\nTestery bezpieczenstwa elektrycznego\nMostki Wzorcowanie — Napiecie DC\nZakres:\n0 mV do 5 mV CMC 6·10⁻⁵ · U + 0,03 µV\n5 mV do 10 mV CMC 7·10⁻⁶ · U + 0,1 µV\n10 mV do 200 mV CMC 6·10⁻⁶ · U + 0,1 µV\n0,2 V do 2 V CMC 4·10⁻⁶ · U + 0,5 µV\n2 V do 20 V CMC 4·10⁻⁶ · U + 5 µV\n20 V do 200 V CMC 5·10⁻⁶ · U + 0,03 mV\n200 V do 1000 V CMC 0,0007 %\n1 kV do 10 kV CMC 0,05 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/3\nLMEEiO/5\nLMEEiO/28\nLMEEiO/35","search_en":"Calibrators DC voltage sources Data acquisition cards Power supplies Breakdown testers Electrical safety testers Bridges Calibration — DC voltage Internal procedure; Direct method; At permanent location (S) and outside of it (P) DC voltage Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/35","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0 mV to 5 mV","cmc":"6·10⁻⁵ · U + 0,03 µV"},{"name":"","range":"5 mV to 10 mV","cmc":"7·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"10 mV to 200 mV","cmc":"6·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"0,2 V to 2 V","cmc":"4·10⁻⁶ · U + 0,5 µV"},{"name":"","range":"2 V to 20 V","cmc":"4·10⁻⁶ · U + 5 µV"},{"name":"","range":"20 V to 200 V","cmc":"5·10⁻⁶ · U + 0,03 mV"},{"name":"","range":"200 V to 1000 V","cmc":"0,0007 %"},{"name":"","range":"1 kV to 10 kV","cmc":"0,05 %"}],"regulatory_area_de":"DC-Spannung","search_de":"Kalibratoren Gleichspannungsquellen Messkarten Netzgeräte Durchschlagprüfgeräte Prüfgeräte für elektrische Sicherheit Messbrücken Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/35","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nGleichspannungsquellen\nMesskarten\nNetzgeräte\nDurchschlagprüfgeräte\nPrüfgeräte für elektrische Sicherheit\nMessbrücken","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0 mV to 5 mV","cmc":"6·10⁻⁵ · U + 0,03 µV"},{"name":"","range":"5 mV to 10 mV","cmc":"7·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"10 mV to 200 mV","cmc":"6·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"0,2 V to 2 V","cmc":"4·10⁻⁶ · U + 0,5 µV"},{"name":"","range":"2 V to 20 V","cmc":"4·10⁻⁶ · U + 5 µV"},{"name":"","range":"20 V to 200 V","cmc":"5·10⁻⁶ · U + 0,03 mV"},{"name":"","range":"200 V to 1000 V","cmc":"0,0007 %"},{"name":"","range":"1 kV to 10 kV","cmc":"0,05 %"}],"regulatory_area_zh":"直流电压","search_zh":"校准器 直流电压源 测量卡 电源 击穿测试仪 电气安全测试仪 电桥 校准 — 直流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 直流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/35","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n直流电压源\n测量卡\n电源\n击穿测试仪\n电气安全测试仪\n电桥","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0 mV to 5 mV","cmc":"6·10⁻⁵ · U + 0,03 µV"},{"name":"","range":"5 mV to 10 mV","cmc":"7·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"10 mV to 200 mV","cmc":"6·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"0,2 V to 2 V","cmc":"4·10⁻⁶ · U + 0,5 µV"},{"name":"","range":"2 V to 20 V","cmc":"4·10⁻⁶ · U + 5 µV"},{"name":"","range":"20 V to 200 V","cmc":"5·10⁻⁶ · U + 0,03 mV"},{"name":"","range":"200 V to 1000 V","cmc":"0,0007 %"},{"name":"","range":"1 kV to 10 kV","cmc":"0,05 %"}],"regulatory_area_cs":"Napětí DC","search_cs":"Kalibrátory Zdroje stejnosměrného napětí Měřicí karty Napájecí zdroje Zkoušečky průrazu Testery elektrické bezpečnosti Můstky Kalibrace — Napětí DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí DC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/35","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nZdroje stejnosměrného napětí\nMěřicí karty\nNapájecí zdroje\nZkoušečky průrazu\nTestery elektrické bezpečnosti\nMůstky"},{"_id":"18873b8bfc9081d41249350f","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Multimetry\nMierniki napięcia cyfrowe\nMierniki napięcia analogowe\nKarty pomiarowe\nSkopometry\nObciążenia elektroniczne\nMierniki parametrów sieci\nTestery bezpieczeństwa elektrycznego\nSondy pomiarowe\nDzielniki napięcia\nMierniki mocy w.cz\nAnalizatory parametrów i uszkodzeń linii","test_object_en":"Multimeters\nDigital voltmeters\nAnalogue voltmeters\nData acquisition cards\nScopemeters\nElectronic loads\nPower network parameter meters\nElectrical safety testers\nMeasuring probes\nVoltage dividers\nRF power meters\nLine parameter and fault analysers","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0 mV do 5 mV","cmc":"6·10⁻⁵ · U + 0,03 µV"},{"name":"","range":"5 mV do 10 mV","cmc":"7·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"10 mV do 200 mV","cmc":"6·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"0,2 V do 2 V","cmc":"4·10⁻⁶ · U + 0,5 µV"},{"name":"","range":"2 V do 20 V","cmc":"4·10⁻⁶ · U + 5 µV"},{"name":"","range":"20 V do 200 V","cmc":"5·10⁻⁶ · U + 0,03 mV"},{"name":"","range":"200 V do 1000 V","cmc":"0,0007 %"}],"parameters_en":[{"name":"","range":"0 mV to 5 mV","cmc":"6·10⁻⁵ · U + 0,03 µV"},{"name":"","range":"5 mV to 10 mV","cmc":"7·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"10 mV to 200 mV","cmc":"6·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"0,2 V to 2 V","cmc":"4·10⁻⁶ · U + 0,5 µV"},{"name":"","range":"2 V to 20 V","cmc":"4·10⁻⁶ · U + 5 µV"},{"name":"","range":"20 V to 200 V","cmc":"5·10⁻⁶ · U + 0,03 mV"},{"name":"","range":"200 V to 1000 V","cmc":"0,0007 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0 mV do 5 mV CMC 6·10⁻⁵ · U + 0,03 µV\n5 mV do 10 mV CMC 7·10⁻⁶ · U + 0,1 µV\n10 mV do 200 mV CMC 6·10⁻⁶ · U + 0,1 µV\n0,2 V do 2 V CMC 4·10⁻⁶ · U + 0,5 µV\n2 V do 20 V CMC 4·10⁻⁶ · U + 5 µV\n20 V do 200 V CMC 5·10⁻⁶ · U + 0,03 mV\n200 V do 1000 V CMC 0,0007 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","norm_bases":["LMEEiO/2","EURAMET cg-15 v. 3.0","LMEEiO/33","LMEEiO/35","LMEEiO/42","LMEEiO/45","LMEEiO/53"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V). Analizatory parametrów i uszkodzeń linii — wyłącznie w stałej lokalizacji (S)","note_en":"U – measured value (V). Line parameter and fault analysers — at permanent location only (S)","search_text":"Multimetry\nMierniki napięcia cyfrowe\nMierniki napięcia analogowe\nKarty pomiarowe\nSkopometry\nObciążenia elektroniczne\nMierniki parametrów sieci\nTestery bezpieczeństwa elektrycznego\nSondy pomiarowe\nDzielniki napięcia\nMierniki mocy w.cz\nAnalizatory parametrów i uszkodzeń linii Wzorcowanie — Napięcie DC\nZakres:\n0 mV do 5 mV CMC 6·10⁻⁵ · U + 0,03 µV\n5 mV do 10 mV CMC 7·10⁻⁶ · U + 0,1 µV\n10 mV do 200 mV CMC 6·10⁻⁶ · U + 0,1 µV\n0,2 V do 2 V CMC 4·10⁻⁶ · U + 0,5 µV\n2 V do 20 V CMC 4·10⁻⁶ · U + 5 µV\n20 V do 200 V CMC 5·10⁻⁶ · U + 0,03 mV\n200 V do 1000 V CMC 0,0007 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53 Multimetry\nMierniki napiecia cyfrowe\nMierniki napiecia analogowe\nKarty pomiarowe\nSkopometry\nObciazenia elektroniczne\nMierniki parametrow sieci\nTestery bezpieczenstwa elektrycznego\nSondy pomiarowe\nDzielniki napiecia\nMierniki mocy w.cz\nAnalizatory parametrow i uszkodzen linii Wzorcowanie — Napiecie DC\nZakres:\n0 mV do 5 mV CMC 6·10⁻⁵ · U + 0,03 µV\n5 mV do 10 mV CMC 7·10⁻⁶ · U + 0,1 µV\n10 mV do 200 mV CMC 6·10⁻⁶ · U + 0,1 µV\n0,2 V do 2 V CMC 4·10⁻⁶ · U + 0,5 µV\n2 V do 20 V CMC 4·10⁻⁶ · U + 5 µV\n20 V do 200 V CMC 5·10⁻⁶ · U + 0,03 mV\n200 V do 1000 V CMC 0,0007 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","search_en":"Multimeters Digital voltmeters Analogue voltmeters Data acquisition cards Scopemeters Electronic loads Power network parameter meters Electrical safety testers Measuring probes Voltage dividers RF power meters Line parameter and fault analysers Calibration — DC voltage Internal procedure; Direct method; At permanent location (S) and outside of it (P) DC voltage Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/2 based on EURAMET cg-15 v. 3.0 LMEEiO/33 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/2 based on EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0 mV to 5 mV","cmc":"6·10⁻⁵ · U + 0,03 µV"},{"name":"","range":"5 mV to 10 mV","cmc":"7·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"10 mV to 200 mV","cmc":"6·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"0,2 V to 2 V","cmc":"4·10⁻⁶ · U + 0,5 µV"},{"name":"","range":"2 V to 20 V","cmc":"4·10⁻⁶ · U + 5 µV"},{"name":"","range":"20 V to 200 V","cmc":"5·10⁻⁶ · U + 0,03 mV"},{"name":"","range":"200 V to 1000 V","cmc":"0,0007 %"}],"reference_de":"LMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","regulatory_area_de":"DC-Spannung","search_de":"Multimeter Digitale Spannungsmessgeräte Analoge Spannungsmessgeräte Messkarten Scopemeter Elektronische Lasten Netzparametermessgeräte Prüfgeräte für elektrische Sicherheit Messsonden Spannungsteiler HF-Leistungsmesser Leitungsparameter- und Fehleranalysatoren Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0 LMEEiO/33 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Multimeter\nDigitale Spannungsmessgeräte\nAnaloge Spannungsmessgeräte\nMesskarten\nScopemeter\nElektronische Lasten\nNetzparametermessgeräte\nPrüfgeräte für elektrische Sicherheit\nMesssonden\nSpannungsteiler\nHF-Leistungsmesser\nLeitungsparameter- und Fehleranalysatoren","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0 mV to 5 mV","cmc":"6·10⁻⁵ · U + 0,03 µV"},{"name":"","range":"5 mV to 10 mV","cmc":"7·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"10 mV to 200 mV","cmc":"6·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"0,2 V to 2 V","cmc":"4·10⁻⁶ · U + 0,5 µV"},{"name":"","range":"2 V to 20 V","cmc":"4·10⁻⁶ · U + 5 µV"},{"name":"","range":"20 V to 200 V","cmc":"5·10⁻⁶ · U + 0,03 mV"},{"name":"","range":"200 V to 1000 V","cmc":"0,0007 %"}],"reference_zh":"LMEEiO/2 依据EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","regulatory_area_zh":"直流电压","search_zh":"万用表 数字电压表 模拟电压表 测量卡 手持示波表 电子负载 电网参数测量仪 电气安全测试仪 测量探头 分压器 射频功率计 线路参数与故障分析仪 校准 — 直流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 直流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/2 依据EURAMET cg-15 v. 3.0 LMEEiO/33 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"万用表\n数字电压表\n模拟电压表\n测量卡\n手持示波表\n电子负载\n电网参数测量仪\n电气安全测试仪\n测量探头\n分压器\n射频功率计\n线路参数与故障分析仪","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0 mV to 5 mV","cmc":"6·10⁻⁵ · U + 0,03 µV"},{"name":"","range":"5 mV to 10 mV","cmc":"7·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"10 mV to 200 mV","cmc":"6·10⁻⁶ · U + 0,1 µV"},{"name":"","range":"0,2 V to 2 V","cmc":"4·10⁻⁶ · U + 0,5 µV"},{"name":"","range":"2 V to 20 V","cmc":"4·10⁻⁶ · U + 5 µV"},{"name":"","range":"20 V to 200 V","cmc":"5·10⁻⁶ · U + 0,03 mV"},{"name":"","range":"200 V to 1000 V","cmc":"0,0007 %"}],"reference_cs":"LMEEiO/2 na základě EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","regulatory_area_cs":"Napětí DC","search_cs":"Multimetry Digitální měřiče napětí Analogové měřiče napětí Měřicí karty Skopmetry Elektronické zátěže Měřiče parametrů sítě Testery elektrické bezpečnosti Měřicí sondy Děliče napětí Měřiče VF výkonu Analyzátory parametrů a poruch vedení Kalibrace — Napětí DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí DC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/2 na základě EURAMET cg-15 v. 3.0 LMEEiO/33 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Multimetry\nDigitální měřiče napětí\nAnalogové měřiče napětí\nMěřicí karty\nSkopmetry\nElektronické zátěže\nMěřiče parametrů sítě\nTestery elektrické bezpečnosti\nMěřicí sondy\nDěliče napětí\nMěřiče VF výkonu\nAnalyzátory parametrů a poruch vedení"},{"_id":"6a4c2c79bf3920b284ad6583","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Oscyloskopy\nKarty pomiarowe\nWewnętrzne źródło odniesienia w oscyloskopach","test_object_en":"Oscilloscopes\nData acquisition cards\nInternal reference source in oscilloscopes","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"1 mV do 222 V","cmc":"3·10⁻⁴· U + 30 µV"},{"name":"wewnętrzne źródło odniesienia w oscyloskopach","range":"0 V do 10 V","cmc":"0,001 %"}],"parameters_en":[{"name":"","range":"1 mV to 222 V","cmc":"3·10⁻⁴· U + 30 µV"},{"name":"internal reference source in oscilloscopes","range":"0 V to 10 V","cmc":"0,001 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n1 mV do 222 V CMC 3·10⁻⁴· U + 30 µV\nwewnętrzne źródło odniesienia w oscyloskopach 0 V do 10 V CMC 0,001 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/13 w oparciu o EURAMET cg-7 v. 1.0","norm_bases":["LMEEiO/13","EURAMET cg-7 v. 1.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured value (V)","search_text":"Oscyloskopy\nKarty pomiarowe\nWewnętrzne źródło odniesienia w oscyloskopach Wzorcowanie — Napięcie DC\nZakres:\n1 mV do 222 V CMC 3·10⁻⁴· U + 30 µV\nwewnętrzne źródło odniesienia w oscyloskopach 0 V do 10 V CMC 0,001 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/13 w oparciu o EURAMET cg-7 v. 1.0 Oscyloskopy\nKarty pomiarowe\nWewnetrzne zrodlo odniesienia w oscyloskopach Wzorcowanie — Napiecie DC\nZakres:\n1 mV do 222 V CMC 3·10⁻⁴· U + 30 µV\nwewnetrzne zrodlo odniesienia w oscyloskopach 0 V do 10 V CMC 0,001 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/13 w oparciu o EURAMET cg-7 v. 1.0","search_en":"Oscilloscopes Data acquisition cards Internal reference source in oscilloscopes Calibration — DC voltage Internal procedure; Direct method; At permanent location (S) and outside of it (P) DC voltage Internal procedure Direct method At permanent location (S) and outside of it (P) internal reference source in oscilloscopes LMEEiO/13 based on EURAMET cg-7 v. 1.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/13 based on EURAMET cg-7 v. 1.0","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"1 mV to 222 V","cmc":"3·10⁻⁴· U + 30 µV"},{"name":"interne Referenzquelle in Oszilloskopen","range":"0 V to 10 V","cmc":"0,001 %"}],"reference_de":"LMEEiO/13 auf Grundlage von EURAMET cg-7 v. 1.0","regulatory_area_de":"DC-Spannung","search_de":"Oszilloskope Messkarten Interne Referenzquelle in Oszilloskopen Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) interne Referenzquelle in Oszilloskopen LMEEiO/13 auf Grundlage von EURAMET cg-7 v. 1.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Oszilloskope\nMesskarten\nInterne Referenzquelle in Oszilloskopen","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"1 mV to 222 V","cmc":"3·10⁻⁴· U + 30 µV"},{"name":"示波器内部参考源","range":"0 V to 10 V","cmc":"0,001 %"}],"reference_zh":"LMEEiO/13 依据EURAMET cg-7 v. 1.0","regulatory_area_zh":"直流电压","search_zh":"示波器 测量卡 示波器内部参考源 校准 — 直流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 直流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 示波器内部参考源 LMEEiO/13 依据EURAMET cg-7 v. 1.0","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"示波器\n测量卡\n示波器内部参考源","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"1 mV to 222 V","cmc":"3·10⁻⁴· U + 30 µV"},{"name":"vnitřní referenční zdroj v osciloskopech","range":"0 V to 10 V","cmc":"0,001 %"}],"reference_cs":"LMEEiO/13 na základě EURAMET cg-7 v. 1.0","regulatory_area_cs":"Napětí DC","search_cs":"Osciloskopy Měřicí karty Vnitřní referenční zdroj v osciloskopech Kalibrace — Napětí DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí DC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) vnitřní referenční zdroj v osciloskopech LMEEiO/13 na základě EURAMET cg-7 v. 1.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Osciloskopy\nMěřicí karty\nVnitřní referenční zdroj v osciloskopech"},{"_id":"e1804fc168ebcbe783af5adb","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Kalibratory\nKarty pomiarowe\nŹródła prądu stałego\nZasilacze\nMierniki parametrów sieci\nTestery bezpieczeństwa elektrycznego\nMostki","test_object_en":"Calibrators\nData acquisition cards\nDC current sources\nPower supplies\nPower network parameter meters\nElectrical safety testers\nBridges","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0 µA do 100 µA","cmc":"4·10⁻⁵ · I + 0,02 nA"},{"name":"","range":"100 µA do 10 A","cmc":"0,002%"},{"name":"","range":"10 A do 100 A","cmc":"0,008%"},{"name":"","range":"100 A do 500 A","cmc":"0,01%"},{"name":"","range":"500 A do 1000 A","cmc":"0,2%"}],"parameters_en":[{"name":"","range":"0 µA to 100 µA","cmc":"4·10⁻⁵ · I + 0,02 nA"},{"name":"","range":"100 µA to 10 A","cmc":"0,002%"},{"name":"","range":"10 A to 100 A","cmc":"0,008%"},{"name":"","range":"100 A to 500 A","cmc":"0,01%"},{"name":"","range":"500 A to 1000 A","cmc":"0,2%"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct and indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0 µA do 100 µA CMC 4·10⁻⁵ · I + 0,02 nA\n100 µA do 10 A CMC 0,002%\n10 A do 100 A CMC 0,008%\n100 A do 500 A CMC 0,01%\n500 A do 1000 A CMC 0,2%\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/3\nLMEEiO/5\nLMEEiO/28\nLMEEiO/35","norm_bases":["LMEEiO/3","LMEEiO/5","LMEEiO/28","LMEEiO/35"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Kalibratory\nKarty pomiarowe\nŹródła prądu stałego\nZasilacze\nMierniki parametrów sieci\nTestery bezpieczeństwa elektrycznego\nMostki Wzorcowanie — Prąd DC\nZakres:\n0 µA do 100 µA CMC 4·10⁻⁵ · I + 0,02 nA\n100 µA do 10 A CMC 0,002%\n10 A do 100 A CMC 0,008%\n100 A do 500 A CMC 0,01%\n500 A do 1000 A CMC 0,2%\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/3\nLMEEiO/5\nLMEEiO/28\nLMEEiO/35 Kalibratory\nKarty pomiarowe\nZrodla pradu stalego\nZasilacze\nMierniki parametrow sieci\nTestery bezpieczenstwa elektrycznego\nMostki Wzorcowanie — Prad DC\nZakres:\n0 µA do 100 µA CMC 4·10⁻⁵ · I + 0,02 nA\n100 µA do 10 A CMC 0,002%\n10 A do 100 A CMC 0,008%\n100 A do 500 A CMC 0,01%\n500 A do 1000 A CMC 0,2%\nProcedura wewnetrzna; Metoda bezposrednia i posrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/3\nLMEEiO/5\nLMEEiO/28\nLMEEiO/35","search_en":"Calibrators Data acquisition cards DC current sources Power supplies Power network parameter meters Electrical safety testers Bridges Calibration — DC current Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) DC current Internal procedure Direct and indirect method At permanent location (S) and outside of it (P) LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/35","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0 µA to 100 µA","cmc":"4·10⁻⁵ · I + 0,02 nA"},{"name":"","range":"100 µA to 10 A","cmc":"0,002%"},{"name":"","range":"10 A to 100 A","cmc":"0,008%"},{"name":"","range":"100 A to 500 A","cmc":"0,01%"},{"name":"","range":"500 A to 1000 A","cmc":"0,2%"}],"regulatory_area_de":"DC-Strom","search_de":"Kalibratoren Messkarten Gleichstromquellen Netzgeräte Netzparametermessgeräte Prüfgeräte für elektrische Sicherheit Messbrücken Kalibrierung — DC-Strom Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Strom Internes Verfahren Direktes und indirektes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/35","technique_de":"Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes und indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nMesskarten\nGleichstromquellen\nNetzgeräte\nNetzparametermessgeräte\nPrüfgeräte für elektrische Sicherheit\nMessbrücken","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0 µA to 100 µA","cmc":"4·10⁻⁵ · I + 0,02 nA"},{"name":"","range":"100 µA to 10 A","cmc":"0,002%"},{"name":"","range":"10 A to 100 A","cmc":"0,008%"},{"name":"","range":"100 A to 500 A","cmc":"0,01%"},{"name":"","range":"500 A to 1000 A","cmc":"0,2%"}],"regulatory_area_zh":"直流电流","search_zh":"校准器 测量卡 直流电流源 电源 电网参数测量仪 电气安全测试仪 电桥 校准 — 直流电流 内部程序；直接法和间接法；在固定地点 (S) 及固定地点以外 (P) 直流电流 内部程序 直接法和间接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/35","technique_zh":"内部程序；直接法和间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法和间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n测量卡\n直流电流源\n电源\n电网参数测量仪\n电气安全测试仪\n电桥","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0 µA to 100 µA","cmc":"4·10⁻⁵ · I + 0,02 nA"},{"name":"","range":"100 µA to 10 A","cmc":"0,002%"},{"name":"","range":"10 A to 100 A","cmc":"0,008%"},{"name":"","range":"100 A to 500 A","cmc":"0,01%"},{"name":"","range":"500 A to 1000 A","cmc":"0,2%"}],"regulatory_area_cs":"Proud DC","search_cs":"Kalibrátory Měřicí karty Zdroje stejnosměrného proudu Napájecí zdroje Měřiče parametrů sítě Testery elektrické bezpečnosti Můstky Kalibrace — Proud DC Vnitřní postup; Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P) Proud DC Vnitřní postup Přímá a nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/35","technique_cs":"Vnitřní postup; Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá a nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nMěřicí karty\nZdroje stejnosměrného proudu\nNapájecí zdroje\nMěřiče parametrů sítě\nTestery elektrické bezpečnosti\nMůstky"},{"_id":"6702d441da6dee181b6fd772","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki prądu cyfrowe\nMierniki prądu analogowe\nMultimetry\nKarty pomiarowe\nSkopometry\nMierniki cęgowe\nTestery bezpieczeństwa elektrycznego\nMierniki parametrów sieci\nSondy pomiarowe\nObciążenia elektroniczne\nAnalizatory parametrów i uszkodzeń linii","test_object_en":"Digital ammeters\nAnalogue ammeters\nMultimeters\nData acquisition cards\nScopemeters\nClamp meters\nElectrical safety testers\nPower network parameter meters\nMeasuring probes\nElectronic loads\nLine parameter and fault analysers","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0 µA do 100 µA","cmc":"4·10⁻⁵ · I + 0,02 nA"},{"name":"","range":"100 µA do 10 A","cmc":"0,002%"},{"name":"","range":"10 A do 100 A","cmc":"0,008%"},{"name":"","range":"100 A do 500 A","cmc":"0,01%"},{"name":"","range":"500 A do 1000 A","cmc":"0,2%"}],"parameters_en":[{"name":"","range":"0 µA to 100 µA","cmc":"4·10⁻⁵ · I + 0,02 nA"},{"name":"","range":"100 µA to 10 A","cmc":"0,002%"},{"name":"","range":"10 A to 100 A","cmc":"0,008%"},{"name":"","range":"100 A to 500 A","cmc":"0,01%"},{"name":"","range":"500 A to 1000 A","cmc":"0,2%"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct and indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0 µA do 100 µA CMC 4·10⁻⁵ · I + 0,02 nA\n100 µA do 10 A CMC 0,002%\n10 A do 100 A CMC 0,008%\n100 A do 500 A CMC 0,01%\n500 A do 1000 A CMC 0,2%\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","norm_bases":["LMEEiO/2","EURAMET cg-15 v. 3.0","LMEEiO/35","LMEEiO/42","LMEEiO/45","LMEEiO/53"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A). Analizatory parametrów i uszkodzeń linii — wyłącznie w stałej lokalizacji (S)","note_en":"I – measured value (A). Line parameter and fault analysers — at permanent location only (S)","search_text":"Mierniki prądu cyfrowe\nMierniki prądu analogowe\nMultimetry\nKarty pomiarowe\nSkopometry\nMierniki cęgowe\nTestery bezpieczeństwa elektrycznego\nMierniki parametrów sieci\nSondy pomiarowe\nObciążenia elektroniczne\nAnalizatory parametrów i uszkodzeń linii Wzorcowanie — Prąd DC\nZakres:\n0 µA do 100 µA CMC 4·10⁻⁵ · I + 0,02 nA\n100 µA do 10 A CMC 0,002%\n10 A do 100 A CMC 0,008%\n100 A do 500 A CMC 0,01%\n500 A do 1000 A CMC 0,2%\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53 Mierniki pradu cyfrowe\nMierniki pradu analogowe\nMultimetry\nKarty pomiarowe\nSkopometry\nMierniki cegowe\nTestery bezpieczenstwa elektrycznego\nMierniki parametrow sieci\nSondy pomiarowe\nObciazenia elektroniczne\nAnalizatory parametrow i uszkodzen linii Wzorcowanie — Prad DC\nZakres:\n0 µA do 100 µA CMC 4·10⁻⁵ · I + 0,02 nA\n100 µA do 10 A CMC 0,002%\n10 A do 100 A CMC 0,008%\n100 A do 500 A CMC 0,01%\n500 A do 1000 A CMC 0,2%\nProcedura wewnetrzna; Metoda bezposrednia i posrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","search_en":"Digital ammeters Analogue ammeters Multimeters Data acquisition cards Scopemeters Clamp meters Electrical safety testers Power network parameter meters Measuring probes Electronic loads Line parameter and fault analysers Calibration — DC current Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) DC current Internal procedure Direct and indirect method At permanent location (S) and outside of it (P) LMEEiO/2 based on EURAMET cg-15 v. 3.0 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/2 based on EURAMET cg-15 v. 3.0\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0 µA to 100 µA","cmc":"4·10⁻⁵ · I + 0,02 nA"},{"name":"","range":"100 µA to 10 A","cmc":"0,002%"},{"name":"","range":"10 A to 100 A","cmc":"0,008%"},{"name":"","range":"100 A to 500 A","cmc":"0,01%"},{"name":"","range":"500 A to 1000 A","cmc":"0,2%"}],"reference_de":"LMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","regulatory_area_de":"DC-Strom","search_de":"Digitale Strommessgeräte Analoge Strommessgeräte Multimeter Messkarten Scopemeter Zangenmessgeräte Prüfgeräte für elektrische Sicherheit Netzparametermessgeräte Messsonden Elektronische Lasten Leitungsparameter- und Fehleranalysatoren Kalibrierung — DC-Strom Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Strom Internes Verfahren Direktes und indirektes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53","technique_de":"Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes und indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Digitale Strommessgeräte\nAnaloge Strommessgeräte\nMultimeter\nMesskarten\nScopemeter\nZangenmessgeräte\nPrüfgeräte für elektrische Sicherheit\nNetzparametermessgeräte\nMesssonden\nElektronische Lasten\nLeitungsparameter- und Fehleranalysatoren","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0 µA to 100 µA","cmc":"4·10⁻⁵ · I + 0,02 nA"},{"name":"","range":"100 µA to 10 A","cmc":"0,002%"},{"name":"","range":"10 A to 100 A","cmc":"0,008%"},{"name":"","range":"100 A to 500 A","cmc":"0,01%"},{"name":"","range":"500 A to 1000 A","cmc":"0,2%"}],"reference_zh":"LMEEiO/2 依据EURAMET cg-15 v. 3.0\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","regulatory_area_zh":"直流电流","search_zh":"数字电流表 模拟电流表 万用表 测量卡 手持示波表 钳形表 电气安全测试仪 电网参数测量仪 测量探头 电子负载 线路参数与故障分析仪 校准 — 直流电流 内部程序；直接法和间接法；在固定地点 (S) 及固定地点以外 (P) 直流电流 内部程序 直接法和间接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/2 依据EURAMET cg-15 v. 3.0 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53","technique_zh":"内部程序；直接法和间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法和间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"数字电流表\n模拟电流表\n万用表\n测量卡\n手持示波表\n钳形表\n电气安全测试仪\n电网参数测量仪\n测量探头\n电子负载\n线路参数与故障分析仪","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0 µA to 100 µA","cmc":"4·10⁻⁵ · I + 0,02 nA"},{"name":"","range":"100 µA to 10 A","cmc":"0,002%"},{"name":"","range":"10 A to 100 A","cmc":"0,008%"},{"name":"","range":"100 A to 500 A","cmc":"0,01%"},{"name":"","range":"500 A to 1000 A","cmc":"0,2%"}],"reference_cs":"LMEEiO/2 na základě EURAMET cg-15 v. 3.0\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","regulatory_area_cs":"Proud DC","search_cs":"Digitální měřiče proudu Analogové měřiče proudu Multimetry Měřicí karty Skopmetry Klešťové měřiče Testery elektrické bezpečnosti Měřiče parametrů sítě Měřicí sondy Elektronické zátěže Analyzátory parametrů a poruch vedení Kalibrace — Proud DC Vnitřní postup; Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P) Proud DC Vnitřní postup Přímá a nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/2 na základě EURAMET cg-15 v. 3.0 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53","technique_cs":"Vnitřní postup; Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá a nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Digitální měřiče proudu\nAnalogové měřiče proudu\nMultimetry\nMěřicí karty\nSkopmetry\nKlešťové měřiče\nTestery elektrické bezpečnosti\nMěřiče parametrů sítě\nMěřicí sondy\nElektronické zátěže\nAnalyzátory parametrů a poruch vedení"},{"_id":"6a0ca563af4f915307ef46b9","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Kalibratory\nKarty pomiarowe\nZasilacze\nMostki\nMierniki parametrów sieci\nTestery bezpieczeństwa elektrycznego\nPróbniki przebicia\nGeneratory w.cz.","test_object_en":"Calibrators\nData acquisition cards\nPower supplies\nBridges\nPower network parameter meters\nElectrical safety testers\nBreakdown testers\nRF generators","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"10 Hz do 40 Hz","range":"0,1 mV do 5 mV","cmc":"3,5·10⁻⁴ · U + 3,5 µV"},{"name":"10 Hz do 40 Hz","range":"5 mV do 12 mV","cmc":"1,5·10⁻⁴ · U + 4,7 µV"},{"name":"10 Hz do 40 Hz","range":"12 mV do 120 mV","cmc":"8·10⁻⁵ · U + 4,7 µ"},{"name":"10 Hz do 40 Hz","range":"0,12 V do 1,2 V","cmc":"8·10⁻⁵ · U + 47 µV"},{"name":"10 Hz do 40 Hz","range":"1,2 V do 12 V","cmc":"8·10⁻⁵ · U + 0,47 m"},{"name":"10 Hz do 40 Hz","range":"12 V do 20 V","cmc":"1,2·10⁻⁴ · U + 0,32 mV"},{"name":"10 Hz do 40 Hz","range":"20 V do 200V","cmc":"1,2·10⁻⁴ · U + 2,5 mV"},{"name":"10 Hz do 40 Hz","range":"200 V do 1000 V","cmc":"1,3·10⁻⁴ · U + 23 mV"},{"name":"20 Hz do 40 Hz","range":"0,22 V do 2,2 V","cmc":"8·10⁻⁵ · U + 22 µV"},{"name":"40 Hz do 50 Hz","range":"200 V do 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"40 Hz do 1 kHz","range":"0,1 mV do 12 mV","cmc":"2,4·10⁻⁴ · U + 1,3 µV"},{"name":"40 Hz do 1 kHz","range":"12 mV do 120 mV","cmc":"8,2·10⁻⁵ · U + 2,3 µV"},{"name":"1 kHz do 20 kHz","range":"0,1 mV do 12 mV","cmc":"3,5·10⁻⁴ · U + 1,3 µV"},{"name":"1 kHz do 20 kHz","range":"12 mV do 120 mV","cmc":"1,2·10⁻⁴ · U + 4,6 µV"},{"name":"40 Hz do 20 kHz","range":"120 mV do 220 mV","cmc":"6,7·10⁻⁵ · U + 8,1 µV"},{"name":"40 Hz do 20 kHz","range":"0,22 V do 2,2 V","cmc":"4,2·10⁻⁵ · U + 12 µV"},{"name":"40 Hz do 20 kHz","range":"2,2 V do 22 V","cmc":"5,0·10⁻⁵ · U + 60 µV"},{"name":"40 Hz do 20 kHz","range":"22 V do 220 V","cmc":"6,0·10⁻⁵ · U + 0,8 mV"},{"name":"50 Hz do 1 kHz","range":"220 V do 1000 V","cmc":"8,0·10⁻⁵ · U + 4,5 mV"},{"name":"1 kHz do 10 kHz","range":"220 V do 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"10 kHz do 33 kHz","range":"220 V do 1000 V","cmc":"1,9·10⁻⁴ · U + 21 mV"},{"name":"20 kHz do 50 kHz","range":"0,1 mV do 2,2 mV","cmc":"3,0·10⁻⁴ · U + 4,6 µV"},{"name":"20 kHz do 50 kHz","range":"2,2 mV do 22 mV","cmc":"2,3·10⁻⁴ · U + 4,7 µV"},{"name":"20 kHz do 50 kHz","range":"22 mV do 220 mV","cmc":"1,4·10⁻⁵ · U + 9 µV"},{"name":"20 kHz do 50 kHz","range":"0,22 V do 2,2 V","cmc":"7,6·10⁻⁵ · U + 13 µV"},{"name":"20 kHz do 50 kHz","range":"2,2 V do 22 V","cmc":"7,8·10⁻⁵ · U + 0,12 mV"},{"name":"20 kHz do 50 kHz","range":"22 V do 220 V","cmc":"9,2·10⁻⁵ · U + 1,2 mV"},{"name":"33 kHz do 100 kHz","range":"220 V do 1000 V","cmc":"6,0·10⁻⁴ · U + 0,23 V"},{"name":"50 kHz do 100 kHz","range":"0,1 mV do 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"50 kHz do 100 kHz","range":"2,2 mV do 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"50 kHz do 100 kHz","range":"22 mV do 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"50 kHz do 100 kHz","range":"0,22 V do 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"50 kHz do 100 kHz","range":"2,2 V do 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"50 kHz do 100 kHz","range":"22 V do 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"100 kHz do 300 kHz","range":"0,1 mV do 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"100 kHz do 300 kHz","range":"2,2 mV do 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"100 kHz do 300 kHz","range":"22 mV do 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"100 kHz do 300 kHz","range":"0,22 V do 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"100 kHz do 300 kHz","range":"2,2 V do 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"100 kHz do 300 kHz","range":"22 V do 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"300 kHz do 1 MHz","range":"2,2 mV do 22 mV","cmc":"3,1·10⁻³ · U + 24 µV"},{"name":"300 kHz do 1 MHz","range":"22 mV do 220 mV","cmc":"3,1·10⁻³ · U + 56 µV"},{"name":"300 kHz do 1 MHz","range":"0,22 V do 2,2 V","cmc":"2,0·10⁻³ · U + 0,34 mV"},{"name":"300 kHz do 1 MHz","range":"2,2 V do 22 V","cmc":"1,8·10⁻³ · U + 3,5 mV"},{"name":"50 Hz do 60 Hz","range":"1 kV do 10 kV","cmc":"0,12 %"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"0,1 mV to 5 mV","cmc":"3,5·10⁻⁴ · U + 3,5 µV"},{"name":"10 Hz to 40 Hz","range":"5 mV to 12 mV","cmc":"1,5·10⁻⁴ · U + 4,7 µV"},{"name":"10 Hz to 40 Hz","range":"12 mV to 120 mV","cmc":"8·10⁻⁵ · U + 4,7 µ"},{"name":"10 Hz to 40 Hz","range":"0,12 V to 1,2 V","cmc":"8·10⁻⁵ · U + 47 µV"},{"name":"10 Hz to 40 Hz","range":"1,2 V to 12 V","cmc":"8·10⁻⁵ · U + 0,47 m"},{"name":"10 Hz to 40 Hz","range":"12 V to 20 V","cmc":"1,2·10⁻⁴ · U + 0,32 mV"},{"name":"10 Hz to 40 Hz","range":"20 V to 200V","cmc":"1,2·10⁻⁴ · U + 2,5 mV"},{"name":"10 Hz to 40 Hz","range":"200 V to 1000 V","cmc":"1,3·10⁻⁴ · U + 23 mV"},{"name":"20 Hz to 40 Hz","range":"0,22 V to 2,2 V","cmc":"8·10⁻⁵ · U + 22 µV"},{"name":"40 Hz to 50 Hz","range":"200 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"40 Hz to 1 kHz","range":"0,1 mV to 12 mV","cmc":"2,4·10⁻⁴ · U + 1,3 µV"},{"name":"40 Hz to 1 kHz","range":"12 mV to 120 mV","cmc":"8,2·10⁻⁵ · U + 2,3 µV"},{"name":"1 kHz to 20 kHz","range":"0,1 mV to 12 mV","cmc":"3,5·10⁻⁴ · U + 1,3 µV"},{"name":"1 kHz to 20 kHz","range":"12 mV to 120 mV","cmc":"1,2·10⁻⁴ · U + 4,6 µV"},{"name":"40 Hz to 20 kHz","range":"120 mV to 220 mV","cmc":"6,7·10⁻⁵ · U + 8,1 µV"},{"name":"40 Hz to 20 kHz","range":"0,22 V to 2,2 V","cmc":"4,2·10⁻⁵ · U + 12 µV"},{"name":"40 Hz to 20 kHz","range":"2,2 V to 22 V","cmc":"5,0·10⁻⁵ · U + 60 µV"},{"name":"40 Hz to 20 kHz","range":"22 V to 220 V","cmc":"6,0·10⁻⁵ · U + 0,8 mV"},{"name":"50 Hz to 1 kHz","range":"220 V to 1000 V","cmc":"8,0·10⁻⁵ · U + 4,5 mV"},{"name":"1 kHz to 10 kHz","range":"220 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"10 kHz to 33 kHz","range":"220 V to 1000 V","cmc":"1,9·10⁻⁴ · U + 21 mV"},{"name":"20 kHz to 50 kHz","range":"0,1 mV to 2,2 mV","cmc":"3,0·10⁻⁴ · U + 4,6 µV"},{"name":"20 kHz to 50 kHz","range":"2,2 mV to 22 mV","cmc":"2,3·10⁻⁴ · U + 4,7 µV"},{"name":"20 kHz to 50 kHz","range":"22 mV to 220 mV","cmc":"1,4·10⁻⁵ · U + 9 µV"},{"name":"20 kHz to 50 kHz","range":"0,22 V to 2,2 V","cmc":"7,6·10⁻⁵ · U + 13 µV"},{"name":"20 kHz to 50 kHz","range":"2,2 V to 22 V","cmc":"7,8·10⁻⁵ · U + 0,12 mV"},{"name":"20 kHz to 50 kHz","range":"22 V to 220 V","cmc":"9,2·10⁻⁵ · U + 1,2 mV"},{"name":"33 kHz to 100 kHz","range":"220 V to 1000 V","cmc":"6,0·10⁻⁴ · U + 0,23 V"},{"name":"50 kHz to 100 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"50 kHz to 100 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"50 kHz to 100 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"50 kHz to 100 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"50 kHz to 100 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"50 kHz to 100 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"100 kHz to 300 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"100 kHz to 300 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"100 kHz to 300 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"100 kHz to 300 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"100 kHz to 300 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"100 kHz to 300 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"300 kHz to 1 MHz","range":"2,2 mV to 22 mV","cmc":"3,1·10⁻³ · U + 24 µV"},{"name":"300 kHz to 1 MHz","range":"22 mV to 220 mV","cmc":"3,1·10⁻³ · U + 56 µV"},{"name":"300 kHz to 1 MHz","range":"0,22 V to 2,2 V","cmc":"2,0·10⁻³ · U + 0,34 mV"},{"name":"300 kHz to 1 MHz","range":"2,2 V to 22 V","cmc":"1,8·10⁻³ · U + 3,5 mV"},{"name":"50 Hz to 60 Hz","range":"1 kV to 10 kV","cmc":"0,12 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 40 Hz 0,1 mV do 5 mV CMC 3,5·10⁻⁴ · U + 3,5 µV\n10 Hz do 40 Hz 5 mV do 12 mV CMC 1,5·10⁻⁴ · U + 4,7 µV\n10 Hz do 40 Hz 12 mV do 120 mV CMC 8·10⁻⁵ · U + 4,7 µ\n10 Hz do 40 Hz 0,12 V do 1,2 V CMC 8·10⁻⁵ · U + 47 µV\n10 Hz do 40 Hz 1,2 V do 12 V CMC 8·10⁻⁵ · U + 0,47 m\n10 Hz do 40 Hz 12 V do 20 V CMC 1,2·10⁻⁴ · U + 0,32 mV\n10 Hz do 40 Hz 20 V do 200V CMC 1,2·10⁻⁴ · U + 2,5 mV\n10 Hz do 40 Hz 200 V do 1000 V CMC 1,3·10⁻⁴ · U + 23 mV\n20 Hz do 40 Hz 0,22 V do 2,2 V CMC 8·10⁻⁵ · U + 22 µV\n40 Hz do 50 Hz 200 V do 1000 V CMC 1,1·10⁻⁴ · U + 23 mV\n40 Hz do 1 kHz 0,1 mV do 12 mV CMC 2,4·10⁻⁴ · U + 1,3 µV\n40 Hz do 1 kHz 12 mV do 120 mV CMC 8,2·10⁻⁵ · U + 2,3 µV\n1 kHz do 20 kHz 0,1 mV do 12 mV CMC 3,5·10⁻⁴ · U + 1,3 µV\n1 kHz do 20 kHz 12 mV do 120 mV CMC 1,2·10⁻⁴ · U + 4,6 µV\n40 Hz do 20 kHz 120 mV do 220 mV CMC 6,7·10⁻⁵ · U + 8,1 µV\n40 Hz do 20 kHz 0,22 V do 2,2 V CMC 4,2·10⁻⁵ · U + 12 µV\n40 Hz do 20 kHz 2,2 V do 22 V CMC 5,0·10⁻⁵ · U + 60 µV\n40 Hz do 20 kHz 22 V do 220 V CMC 6,0·10⁻⁵ · U + 0,8 mV\n50 Hz do 1 kHz 220 V do 1000 V CMC 8,0·10⁻⁵ · U + 4,5 mV\n1 kHz do 10 kHz 220 V do 1000 V CMC 1,1·10⁻⁴ · U + 23 mV\n10 kHz do 33 kHz 220 V do 1000 V CMC 1,9·10⁻⁴ · U + 21 mV\n20 kHz do 50 kHz 0,1 mV do 2,2 mV CMC 3,0·10⁻⁴ · U + 4,6 µV\n20 kHz do 50 kHz 2,2 mV do 22 mV CMC 2,3·10⁻⁴ · U + 4,7 µV\n20 kHz do 50 kHz 22 mV do 220 mV CMC 1,4·10⁻⁵ · U + 9 µV\n20 kHz do 50 kHz 0,22 V do 2,2 V CMC 7,6·10⁻⁵ · U + 13 µV\n20 kHz do 50 kHz 2,2 V do 22 V CMC 7,8·10⁻⁵ · U + 0,12 mV\n20 kHz do 50 kHz 22 V do 220 V CMC 9,2·10⁻⁵ · U + 1,2 mV\n33 kHz do 100 kHz 220 V do 1000 V CMC 6,0·10⁻⁴ · U + 0,23 V\n50 kHz do 100 kHz 0,1 mV do 2,2 mV CMC 5,0·10⁻⁴ · U + 6 µV\n50 kHz do 100 kHz 2,2 mV do 22 mV CMC 6,0·10⁻⁴ · U + 5,7 µV\n50 kHz do 100 kHz 22 mV do 220 mV CMC 3,6·10⁻⁴ · U + 20 µV\n50 kHz do 100 kHz 0,22 V do 2,2 V CMC 1,0·10⁻⁴ · U + 34 µV\n50 kHz do 100 kHz 2,2 V do 22 V CMC 9,5·10⁻⁵ · U + 0,23 mV\n50 kHz do 100 kHz 22 V do 220 V CMC 1,8·10⁻⁴ · U + 2,7 mV\n100 kHz do 300 kHz 0,1 mV do 2,2 mV CMC 5,0·10⁻⁴ · U + 6 µV\n100 kHz do 300 kHz 2,2 mV do 22 mV CMC 6,0·10⁻⁴ · U + 5,7 µV\n100 kHz do 300 kHz 22 mV do 220 mV CMC 3,6·10⁻⁴ · U + 20 µV\n100 kHz do 300 kHz 0,22 V do 2,2 V CMC 1,0·10⁻⁴ · U + 34 µV\n100 kHz do 300 kHz 2,2 V do 22 V CMC 9,5·10⁻⁵ · U + 0,23 mV\n100 kHz do 300 kHz 22 V do 220 V CMC 1,8·10⁻⁴ · U + 2,7 mV\n300 kHz do 1 MHz 2,2 mV do 22 mV CMC 3,1·10⁻³ · U + 24 µV\n300 kHz do 1 MHz 22 mV do 220 mV CMC 3,1·10⁻³ · U + 56 µV\n300 kHz do 1 MHz 0,22 V do 2,2 V CMC 2,0·10⁻³ · U + 0,34 mV\n300 kHz do 1 MHz 2,2 V do 22 V CMC 1,8·10⁻³ · U + 3,5 mV\n50 Hz do 60 Hz 1 kV do 10 kV CMC 0,12 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/3\nLMEEiO/5\nLMEEiO/28\nLMEEiO/32\nLMEEiO/35\nLMEEiO/45","norm_bases":["LMEEiO/3","LMEEiO/5","LMEEiO/28","LMEEiO/32","LMEEiO/35","LMEEiO/45"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured value (V)","search_text":"Kalibratory\nKarty pomiarowe\nZasilacze\nMostki\nMierniki parametrów sieci\nTestery bezpieczeństwa elektrycznego\nPróbniki przebicia\nGeneratory w.cz. Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 40 Hz 0,1 mV do 5 mV CMC 3,5·10⁻⁴ · U + 3,5 µV\n10 Hz do 40 Hz 5 mV do 12 mV CMC 1,5·10⁻⁴ · U + 4,7 µV\n10 Hz do 40 Hz 12 mV do 120 mV CMC 8·10⁻⁵ · U + 4,7 µ\n10 Hz do 40 Hz 0,12 V do 1,2 V CMC 8·10⁻⁵ · U + 47 µV\n10 Hz do 40 Hz 1,2 V do 12 V CMC 8·10⁻⁵ · U + 0,47 m\n10 Hz do 40 Hz 12 V do 20 V CMC 1,2·10⁻⁴ · U + 0,32 mV\n10 Hz do 40 Hz 20 V do 200V CMC 1,2·10⁻⁴ · U + 2,5 mV\n10 Hz do 40 Hz 200 V do 1000 V CMC 1,3·10⁻⁴ · U + 23 mV\n20 Hz do 40 Hz 0,22 V do 2,2 V CMC 8·10⁻⁵ · U + 22 µV\n40 Hz do 50 Hz 200 V do 1000 V CMC 1,1·10⁻⁴ · U + 23 mV\n40 Hz do 1 kHz 0,1 mV do 12 mV CMC 2,4·10⁻⁴ · U + 1,3 µV\n40 Hz do 1 kHz 12 mV do 120 mV CMC 8,2·10⁻⁵ · U + 2,3 µV\n1 kHz do 20 kHz 0,1 mV do 12 mV CMC 3,5·10⁻⁴ · U + 1,3 µV\n1 kHz do 20 kHz 12 mV do 120 mV CMC 1,2·10⁻⁴ · U + 4,6 µV\n40 Hz do 20 kHz 120 mV do 220 mV CMC 6,7·10⁻⁵ · U + 8,1 µV\n40 Hz do 20 kHz 0,22 V do 2,2 V CMC 4,2·10⁻⁵ · U + 12 µV\n40 Hz do 20 kHz 2,2 V do 22 V CMC 5,0·10⁻⁵ · U + 60 µV\n40 Hz do 20 kHz 22 V do 220 V CMC 6,0·10⁻⁵ · U + 0,8 mV\n50 Hz do 1 kHz 220 V do 1000 V CMC 8,0·10⁻⁵ · U + 4,5 mV\n1 kHz do 10 kHz 220 V do 1000 V CMC 1,1·10⁻⁴ · U + 23 mV\n10 kHz do 33 kHz 220 V do 1000 V CMC 1,9·10⁻⁴ · U + 21 mV\n20 kHz do 50 kHz 0,1 mV do 2,2 mV CMC 3,0·10⁻⁴ · U + 4,6 µV\n20 kHz do 50 kHz 2,2 mV do 22 mV CMC 2,3·10⁻⁴ · U + 4,7 µV\n20 kHz do 50 kHz 22 mV do 220 mV CMC 1,4·10⁻⁵ · U + 9 µV\n20 kHz do 50 kHz 0,22 V do 2,2 V CMC 7,6·10⁻⁵ · U + 13 µV\n20 kHz do 50 kHz 2,2 V do 22 V CMC 7,8·10⁻⁵ · U + 0,12 mV\n20 kHz do 50 kHz 22 V do 220 V CMC 9,2·10⁻⁵ · U + 1,2 mV\n33 kHz do 100 kHz 220 V do 1000 V CMC 6,0·10⁻⁴ · U + 0,23 V\n50 kHz do 100 kHz 0,1 mV do 2,2 mV CMC 5,0·10⁻⁴ · U + 6 µV\n50 kHz do 100 kHz 2,2 mV do 22 mV CMC 6,0·10⁻⁴ · U + 5,7 µV\n50 kHz do 100 kHz 22 mV do 220 mV CMC 3,6·10⁻⁴ · U + 20 µV\n50 kHz do 100 kHz 0,22 V do 2,2 V CMC 1,0·10⁻⁴ · U + 34 µV\n50 kHz do 100 kHz 2,2 V do 22 V CMC 9,5·10⁻⁵ · U + 0,23 mV\n50 kHz do 100 kHz 22 V do 220 V CMC 1,8·10⁻⁴ · U + 2,7 mV\n100 kHz do 300 kHz 0,1 mV do 2,2 mV CMC 5,0·10⁻⁴ · U + 6 µV\n100 kHz do 300 kHz 2,2 mV do 22 mV CMC 6,0·10⁻⁴ · U + 5,7 µV\n100 kHz do 300 kHz 22 mV do 220 mV CMC 3,6·10⁻⁴ · U + 20 µV\n100 kHz do 300 kHz 0,22 V do 2,2 V CMC 1,0·10⁻⁴ · U + 34 µV\n100 kHz do 300 kHz 2,2 V do 22 V CMC 9,5·10⁻⁵ · U + 0,23 mV\n100 kHz do 300 kHz 22 V do 220 V CMC 1,8·10⁻⁴ · U + 2,7 mV\n300 kHz do 1 MHz 2,2 mV do 22 mV CMC 3,1·10⁻³ · U + 24 µV\n300 kHz do 1 MHz 22 mV do 220 mV CMC 3,1·10⁻³ · U + 56 µV\n300 kHz do 1 MHz 0,22 V do 2,2 V CMC 2,0·10⁻³ · U + 0,34 mV\n300 kHz do 1 MHz 2,2 V do 22 V CMC 1,8·10⁻³ · U + 3,5 mV\n50 Hz do 60 Hz 1 kV do 10 kV CMC 0,12 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/3\nLMEEiO/5\nLMEEiO/28\nLMEEiO/32\nLMEEiO/35\nLMEEiO/45 Kalibratory\nKarty pomiarowe\nZasilacze\nMostki\nMierniki parametrow sieci\nTestery bezpieczenstwa elektrycznego\nProbniki przebicia\nGeneratory w.cz. Wzorcowanie — Napiecie AC\nZakres:\n10 Hz do 40 Hz 0,1 mV do 5 mV CMC 3,5·10⁻⁴ · U + 3,5 µV\n10 Hz do 40 Hz 5 mV do 12 mV CMC 1,5·10⁻⁴ · U + 4,7 µV\n10 Hz do 40 Hz 12 mV do 120 mV CMC 8·10⁻⁵ · U + 4,7 µ\n10 Hz do 40 Hz 0,12 V do 1,2 V CMC 8·10⁻⁵ · U + 47 µV\n10 Hz do 40 Hz 1,2 V do 12 V CMC 8·10⁻⁵ · U + 0,47 m\n10 Hz do 40 Hz 12 V do 20 V CMC 1,2·10⁻⁴ · U + 0,32 mV\n10 Hz do 40 Hz 20 V do 200V CMC 1,2·10⁻⁴ · U + 2,5 mV\n10 Hz do 40 Hz 200 V do 1000 V CMC 1,3·10⁻⁴ · U + 23 mV\n20 Hz do 40 Hz 0,22 V do 2,2 V CMC 8·10⁻⁵ · U + 22 µV\n40 Hz do 50 Hz 200 V do 1000 V CMC 1,1·10⁻⁴ · U + 23 mV\n40 Hz do 1 kHz 0,1 mV do 12 mV CMC 2,4·10⁻⁴ · U + 1,3 µV\n40 Hz do 1 kHz 12 mV do 120 mV CMC 8,2·10⁻⁵ · U + 2,3 µV\n1 kHz do 20 kHz 0,1 mV do 12 mV CMC 3,5·10⁻⁴ · U + 1,3 µV\n1 kHz do 20 kHz 12 mV do 120 mV CMC 1,2·10⁻⁴ · U + 4,6 µV\n40 Hz do 20 kHz 120 mV do 220 mV CMC 6,7·10⁻⁵ · U + 8,1 µV\n40 Hz do 20 kHz 0,22 V do 2,2 V CMC 4,2·10⁻⁵ · U + 12 µV\n40 Hz do 20 kHz 2,2 V do 22 V CMC 5,0·10⁻⁵ · U + 60 µV\n40 Hz do 20 kHz 22 V do 220 V CMC 6,0·10⁻⁵ · U + 0,8 mV\n50 Hz do 1 kHz 220 V do 1000 V CMC 8,0·10⁻⁵ · U + 4,5 mV\n1 kHz do 10 kHz 220 V do 1000 V CMC 1,1·10⁻⁴ · U + 23 mV\n10 kHz do 33 kHz 220 V do 1000 V CMC 1,9·10⁻⁴ · U + 21 mV\n20 kHz do 50 kHz 0,1 mV do 2,2 mV CMC 3,0·10⁻⁴ · U + 4,6 µV\n20 kHz do 50 kHz 2,2 mV do 22 mV CMC 2,3·10⁻⁴ · U + 4,7 µV\n20 kHz do 50 kHz 22 mV do 220 mV CMC 1,4·10⁻⁵ · U + 9 µV\n20 kHz do 50 kHz 0,22 V do 2,2 V CMC 7,6·10⁻⁵ · U + 13 µV\n20 kHz do 50 kHz 2,2 V do 22 V CMC 7,8·10⁻⁵ · U + 0,12 mV\n20 kHz do 50 kHz 22 V do 220 V CMC 9,2·10⁻⁵ · U + 1,2 mV\n33 kHz do 100 kHz 220 V do 1000 V CMC 6,0·10⁻⁴ · U + 0,23 V\n50 kHz do 100 kHz 0,1 mV do 2,2 mV CMC 5,0·10⁻⁴ · U + 6 µV\n50 kHz do 100 kHz 2,2 mV do 22 mV CMC 6,0·10⁻⁴ · U + 5,7 µV\n50 kHz do 100 kHz 22 mV do 220 mV CMC 3,6·10⁻⁴ · U + 20 µV\n50 kHz do 100 kHz 0,22 V do 2,2 V CMC 1,0·10⁻⁴ · U + 34 µV\n50 kHz do 100 kHz 2,2 V do 22 V CMC 9,5·10⁻⁵ · U + 0,23 mV\n50 kHz do 100 kHz 22 V do 220 V CMC 1,8·10⁻⁴ · U + 2,7 mV\n100 kHz do 300 kHz 0,1 mV do 2,2 mV CMC 5,0·10⁻⁴ · U + 6 µV\n100 kHz do 300 kHz 2,2 mV do 22 mV CMC 6,0·10⁻⁴ · U + 5,7 µV\n100 kHz do 300 kHz 22 mV do 220 mV CMC 3,6·10⁻⁴ · U + 20 µV\n100 kHz do 300 kHz 0,22 V do 2,2 V CMC 1,0·10⁻⁴ · U + 34 µV\n100 kHz do 300 kHz 2,2 V do 22 V CMC 9,5·10⁻⁵ · U + 0,23 mV\n100 kHz do 300 kHz 22 V do 220 V CMC 1,8·10⁻⁴ · U + 2,7 mV\n300 kHz do 1 MHz 2,2 mV do 22 mV CMC 3,1·10⁻³ · U + 24 µV\n300 kHz do 1 MHz 22 mV do 220 mV CMC 3,1·10⁻³ · U + 56 µV\n300 kHz do 1 MHz 0,22 V do 2,2 V CMC 2,0·10⁻³ · U + 0,34 mV\n300 kHz do 1 MHz 2,2 V do 22 V CMC 1,8·10⁻³ · U + 3,5 mV\n50 Hz do 60 Hz 1 kV do 10 kV CMC 0,12 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/3\nLMEEiO/5\nLMEEiO/28\nLMEEiO/32\nLMEEiO/35\nLMEEiO/45","search_en":"Calibrators Data acquisition cards Power supplies Bridges Power network parameter meters Electrical safety testers Breakdown testers RF generators Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC voltage Internal procedure Direct method At permanent location (S) and outside of it (P) 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 20 Hz to 40 Hz 40 Hz to 50 Hz 40 Hz to 1 kHz 40 Hz to 1 kHz 1 kHz to 20 kHz 1 kHz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 50 Hz to 1 kHz 1 kHz to 10 kHz 10 kHz to 33 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 33 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 300 kHz to 1 MHz 300 kHz to 1 MHz 300 kHz to 1 MHz 300 kHz to 1 MHz 50 Hz to 60 Hz LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/32 LMEEiO/35 LMEEiO/45","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"10 Hz bis 40 Hz","range":"0,1 mV to 5 mV","cmc":"3,5·10⁻⁴ · U + 3,5 µV"},{"name":"10 Hz bis 40 Hz","range":"5 mV to 12 mV","cmc":"1,5·10⁻⁴ · U + 4,7 µV"},{"name":"10 Hz bis 40 Hz","range":"12 mV to 120 mV","cmc":"8·10⁻⁵ · U + 4,7 µ"},{"name":"10 Hz bis 40 Hz","range":"0,12 V to 1,2 V","cmc":"8·10⁻⁵ · U + 47 µV"},{"name":"10 Hz bis 40 Hz","range":"1,2 V to 12 V","cmc":"8·10⁻⁵ · U + 0,47 m"},{"name":"10 Hz bis 40 Hz","range":"12 V to 20 V","cmc":"1,2·10⁻⁴ · U + 0,32 mV"},{"name":"10 Hz bis 40 Hz","range":"20 V to 200V","cmc":"1,2·10⁻⁴ · U + 2,5 mV"},{"name":"10 Hz bis 40 Hz","range":"200 V to 1000 V","cmc":"1,3·10⁻⁴ · U + 23 mV"},{"name":"20 Hz bis 40 Hz","range":"0,22 V to 2,2 V","cmc":"8·10⁻⁵ · U + 22 µV"},{"name":"40 Hz bis 50 Hz","range":"200 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"40 Hz bis 1 kHz","range":"0,1 mV to 12 mV","cmc":"2,4·10⁻⁴ · U + 1,3 µV"},{"name":"40 Hz bis 1 kHz","range":"12 mV to 120 mV","cmc":"8,2·10⁻⁵ · U + 2,3 µV"},{"name":"1 kHz bis 20 kHz","range":"0,1 mV to 12 mV","cmc":"3,5·10⁻⁴ · U + 1,3 µV"},{"name":"1 kHz bis 20 kHz","range":"12 mV to 120 mV","cmc":"1,2·10⁻⁴ · U + 4,6 µV"},{"name":"40 Hz bis 20 kHz","range":"120 mV to 220 mV","cmc":"6,7·10⁻⁵ · U + 8,1 µV"},{"name":"40 Hz bis 20 kHz","range":"0,22 V to 2,2 V","cmc":"4,2·10⁻⁵ · U + 12 µV"},{"name":"40 Hz bis 20 kHz","range":"2,2 V to 22 V","cmc":"5,0·10⁻⁵ · U + 60 µV"},{"name":"40 Hz bis 20 kHz","range":"22 V to 220 V","cmc":"6,0·10⁻⁵ · U + 0,8 mV"},{"name":"50 Hz bis 1 kHz","range":"220 V to 1000 V","cmc":"8,0·10⁻⁵ · U + 4,5 mV"},{"name":"1 kHz bis 10 kHz","range":"220 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"10 kHz bis 33 kHz","range":"220 V to 1000 V","cmc":"1,9·10⁻⁴ · U + 21 mV"},{"name":"20 kHz bis 50 kHz","range":"0,1 mV to 2,2 mV","cmc":"3,0·10⁻⁴ · U + 4,6 µV"},{"name":"20 kHz bis 50 kHz","range":"2,2 mV to 22 mV","cmc":"2,3·10⁻⁴ · U + 4,7 µV"},{"name":"20 kHz bis 50 kHz","range":"22 mV to 220 mV","cmc":"1,4·10⁻⁵ · U + 9 µV"},{"name":"20 kHz bis 50 kHz","range":"0,22 V to 2,2 V","cmc":"7,6·10⁻⁵ · U + 13 µV"},{"name":"20 kHz bis 50 kHz","range":"2,2 V to 22 V","cmc":"7,8·10⁻⁵ · U + 0,12 mV"},{"name":"20 kHz bis 50 kHz","range":"22 V to 220 V","cmc":"9,2·10⁻⁵ · U + 1,2 mV"},{"name":"33 kHz bis 100 kHz","range":"220 V to 1000 V","cmc":"6,0·10⁻⁴ · U + 0,23 V"},{"name":"50 kHz bis 100 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"50 kHz bis 100 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"50 kHz bis 100 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"50 kHz bis 100 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"50 kHz bis 100 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"50 kHz bis 100 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"100 kHz bis 300 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"100 kHz bis 300 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"100 kHz bis 300 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"100 kHz bis 300 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"100 kHz bis 300 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"100 kHz bis 300 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"300 kHz bis 1 MHz","range":"2,2 mV to 22 mV","cmc":"3,1·10⁻³ · U + 24 µV"},{"name":"300 kHz bis 1 MHz","range":"22 mV to 220 mV","cmc":"3,1·10⁻³ · U + 56 µV"},{"name":"300 kHz bis 1 MHz","range":"0,22 V to 2,2 V","cmc":"2,0·10⁻³ · U + 0,34 mV"},{"name":"300 kHz bis 1 MHz","range":"2,2 V to 22 V","cmc":"1,8·10⁻³ · U + 3,5 mV"},{"name":"50 Hz bis 60 Hz","range":"1 kV to 10 kV","cmc":"0,12 %"}],"regulatory_area_de":"AC-Spannung","search_de":"Kalibratoren Messkarten Netzgeräte Messbrücken Netzparametermessgeräte Prüfgeräte für elektrische Sicherheit Durchschlagprüfgeräte HF-Generatoren Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 20 Hz bis 40 Hz 40 Hz bis 50 Hz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 1 kHz bis 20 kHz 1 kHz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 50 Hz bis 1 kHz 1 kHz bis 10 kHz 10 kHz bis 33 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 33 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 300 kHz bis 1 MHz 300 kHz bis 1 MHz 300 kHz bis 1 MHz 300 kHz bis 1 MHz 50 Hz bis 60 Hz LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/32 LMEEiO/35 LMEEiO/45","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nMesskarten\nNetzgeräte\nMessbrücken\nNetzparametermessgeräte\nPrüfgeräte für elektrische Sicherheit\nDurchschlagprüfgeräte\nHF-Generatoren","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"0,1 mV to 5 mV","cmc":"3,5·10⁻⁴ · U + 3,5 µV"},{"name":"10 Hz 至 40 Hz","range":"5 mV to 12 mV","cmc":"1,5·10⁻⁴ · U + 4,7 µV"},{"name":"10 Hz 至 40 Hz","range":"12 mV to 120 mV","cmc":"8·10⁻⁵ · U + 4,7 µ"},{"name":"10 Hz 至 40 Hz","range":"0,12 V to 1,2 V","cmc":"8·10⁻⁵ · U + 47 µV"},{"name":"10 Hz 至 40 Hz","range":"1,2 V to 12 V","cmc":"8·10⁻⁵ · U + 0,47 m"},{"name":"10 Hz 至 40 Hz","range":"12 V to 20 V","cmc":"1,2·10⁻⁴ · U + 0,32 mV"},{"name":"10 Hz 至 40 Hz","range":"20 V to 200V","cmc":"1,2·10⁻⁴ · U + 2,5 mV"},{"name":"10 Hz 至 40 Hz","range":"200 V to 1000 V","cmc":"1,3·10⁻⁴ · U + 23 mV"},{"name":"20 Hz 至 40 Hz","range":"0,22 V to 2,2 V","cmc":"8·10⁻⁵ · U + 22 µV"},{"name":"40 Hz 至 50 Hz","range":"200 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"40 Hz 至 1 kHz","range":"0,1 mV to 12 mV","cmc":"2,4·10⁻⁴ · U + 1,3 µV"},{"name":"40 Hz 至 1 kHz","range":"12 mV to 120 mV","cmc":"8,2·10⁻⁵ · U + 2,3 µV"},{"name":"1 kHz 至 20 kHz","range":"0,1 mV to 12 mV","cmc":"3,5·10⁻⁴ · U + 1,3 µV"},{"name":"1 kHz 至 20 kHz","range":"12 mV to 120 mV","cmc":"1,2·10⁻⁴ · U + 4,6 µV"},{"name":"40 Hz 至 20 kHz","range":"120 mV to 220 mV","cmc":"6,7·10⁻⁵ · U + 8,1 µV"},{"name":"40 Hz 至 20 kHz","range":"0,22 V to 2,2 V","cmc":"4,2·10⁻⁵ · U + 12 µV"},{"name":"40 Hz 至 20 kHz","range":"2,2 V to 22 V","cmc":"5,0·10⁻⁵ · U + 60 µV"},{"name":"40 Hz 至 20 kHz","range":"22 V to 220 V","cmc":"6,0·10⁻⁵ · U + 0,8 mV"},{"name":"50 Hz 至 1 kHz","range":"220 V to 1000 V","cmc":"8,0·10⁻⁵ · U + 4,5 mV"},{"name":"1 kHz 至 10 kHz","range":"220 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"10 kHz 至 33 kHz","range":"220 V to 1000 V","cmc":"1,9·10⁻⁴ · U + 21 mV"},{"name":"20 kHz 至 50 kHz","range":"0,1 mV to 2,2 mV","cmc":"3,0·10⁻⁴ · U + 4,6 µV"},{"name":"20 kHz 至 50 kHz","range":"2,2 mV to 22 mV","cmc":"2,3·10⁻⁴ · U + 4,7 µV"},{"name":"20 kHz 至 50 kHz","range":"22 mV to 220 mV","cmc":"1,4·10⁻⁵ · U + 9 µV"},{"name":"20 kHz 至 50 kHz","range":"0,22 V to 2,2 V","cmc":"7,6·10⁻⁵ · U + 13 µV"},{"name":"20 kHz 至 50 kHz","range":"2,2 V to 22 V","cmc":"7,8·10⁻⁵ · U + 0,12 mV"},{"name":"20 kHz 至 50 kHz","range":"22 V to 220 V","cmc":"9,2·10⁻⁵ · U + 1,2 mV"},{"name":"33 kHz 至 100 kHz","range":"220 V to 1000 V","cmc":"6,0·10⁻⁴ · U + 0,23 V"},{"name":"50 kHz 至 100 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"50 kHz 至 100 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"50 kHz 至 100 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"50 kHz 至 100 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"50 kHz 至 100 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"50 kHz 至 100 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"100 kHz 至 300 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"100 kHz 至 300 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"100 kHz 至 300 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"100 kHz 至 300 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"100 kHz 至 300 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"100 kHz 至 300 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"300 kHz 至 1 MHz","range":"2,2 mV to 22 mV","cmc":"3,1·10⁻³ · U + 24 µV"},{"name":"300 kHz 至 1 MHz","range":"22 mV to 220 mV","cmc":"3,1·10⁻³ · U + 56 µV"},{"name":"300 kHz 至 1 MHz","range":"0,22 V to 2,2 V","cmc":"2,0·10⁻³ · U + 0,34 mV"},{"name":"300 kHz 至 1 MHz","range":"2,2 V to 22 V","cmc":"1,8·10⁻³ · U + 3,5 mV"},{"name":"50 Hz 至 60 Hz","range":"1 kV to 10 kV","cmc":"0,12 %"}],"regulatory_area_zh":"交流电压","search_zh":"校准器 测量卡 电源 电桥 电网参数测量仪 电气安全测试仪 击穿测试仪 射频发生器 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 20 Hz 至 40 Hz 40 Hz 至 50 Hz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 1 kHz 至 20 kHz 1 kHz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 50 Hz 至 1 kHz 1 kHz 至 10 kHz 10 kHz 至 33 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 33 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 300 kHz 至 1 MHz 300 kHz 至 1 MHz 300 kHz 至 1 MHz 300 kHz 至 1 MHz 50 Hz 至 60 Hz LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/32 LMEEiO/35 LMEEiO/45","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n测量卡\n电源\n电桥\n电网参数测量仪\n电气安全测试仪\n击穿测试仪\n射频发生器","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"10 Hz až 40 Hz","range":"0,1 mV to 5 mV","cmc":"3,5·10⁻⁴ · U + 3,5 µV"},{"name":"10 Hz až 40 Hz","range":"5 mV to 12 mV","cmc":"1,5·10⁻⁴ · U + 4,7 µV"},{"name":"10 Hz až 40 Hz","range":"12 mV to 120 mV","cmc":"8·10⁻⁵ · U + 4,7 µ"},{"name":"10 Hz až 40 Hz","range":"0,12 V to 1,2 V","cmc":"8·10⁻⁵ · U + 47 µV"},{"name":"10 Hz až 40 Hz","range":"1,2 V to 12 V","cmc":"8·10⁻⁵ · U + 0,47 m"},{"name":"10 Hz až 40 Hz","range":"12 V to 20 V","cmc":"1,2·10⁻⁴ · U + 0,32 mV"},{"name":"10 Hz až 40 Hz","range":"20 V to 200V","cmc":"1,2·10⁻⁴ · U + 2,5 mV"},{"name":"10 Hz až 40 Hz","range":"200 V to 1000 V","cmc":"1,3·10⁻⁴ · U + 23 mV"},{"name":"20 Hz až 40 Hz","range":"0,22 V to 2,2 V","cmc":"8·10⁻⁵ · U + 22 µV"},{"name":"40 Hz až 50 Hz","range":"200 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"40 Hz až 1 kHz","range":"0,1 mV to 12 mV","cmc":"2,4·10⁻⁴ · U + 1,3 µV"},{"name":"40 Hz až 1 kHz","range":"12 mV to 120 mV","cmc":"8,2·10⁻⁵ · U + 2,3 µV"},{"name":"1 kHz až 20 kHz","range":"0,1 mV to 12 mV","cmc":"3,5·10⁻⁴ · U + 1,3 µV"},{"name":"1 kHz až 20 kHz","range":"12 mV to 120 mV","cmc":"1,2·10⁻⁴ · U + 4,6 µV"},{"name":"40 Hz až 20 kHz","range":"120 mV to 220 mV","cmc":"6,7·10⁻⁵ · U + 8,1 µV"},{"name":"40 Hz až 20 kHz","range":"0,22 V to 2,2 V","cmc":"4,2·10⁻⁵ · U + 12 µV"},{"name":"40 Hz až 20 kHz","range":"2,2 V to 22 V","cmc":"5,0·10⁻⁵ · U + 60 µV"},{"name":"40 Hz až 20 kHz","range":"22 V to 220 V","cmc":"6,0·10⁻⁵ · U + 0,8 mV"},{"name":"50 Hz až 1 kHz","range":"220 V to 1000 V","cmc":"8,0·10⁻⁵ · U + 4,5 mV"},{"name":"1 kHz až 10 kHz","range":"220 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"10 kHz až 33 kHz","range":"220 V to 1000 V","cmc":"1,9·10⁻⁴ · U + 21 mV"},{"name":"20 kHz až 50 kHz","range":"0,1 mV to 2,2 mV","cmc":"3,0·10⁻⁴ · U + 4,6 µV"},{"name":"20 kHz až 50 kHz","range":"2,2 mV to 22 mV","cmc":"2,3·10⁻⁴ · U + 4,7 µV"},{"name":"20 kHz až 50 kHz","range":"22 mV to 220 mV","cmc":"1,4·10⁻⁵ · U + 9 µV"},{"name":"20 kHz až 50 kHz","range":"0,22 V to 2,2 V","cmc":"7,6·10⁻⁵ · U + 13 µV"},{"name":"20 kHz až 50 kHz","range":"2,2 V to 22 V","cmc":"7,8·10⁻⁵ · U + 0,12 mV"},{"name":"20 kHz až 50 kHz","range":"22 V to 220 V","cmc":"9,2·10⁻⁵ · U + 1,2 mV"},{"name":"33 kHz až 100 kHz","range":"220 V to 1000 V","cmc":"6,0·10⁻⁴ · U + 0,23 V"},{"name":"50 kHz až 100 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"50 kHz až 100 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"50 kHz až 100 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"50 kHz až 100 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"50 kHz až 100 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"50 kHz až 100 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"100 kHz až 300 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"100 kHz až 300 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"100 kHz až 300 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"100 kHz až 300 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"100 kHz až 300 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"100 kHz až 300 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"300 kHz až 1 MHz","range":"2,2 mV to 22 mV","cmc":"3,1·10⁻³ · U + 24 µV"},{"name":"300 kHz až 1 MHz","range":"22 mV to 220 mV","cmc":"3,1·10⁻³ · U + 56 µV"},{"name":"300 kHz až 1 MHz","range":"0,22 V to 2,2 V","cmc":"2,0·10⁻³ · U + 0,34 mV"},{"name":"300 kHz až 1 MHz","range":"2,2 V to 22 V","cmc":"1,8·10⁻³ · U + 3,5 mV"},{"name":"50 Hz až 60 Hz","range":"1 kV to 10 kV","cmc":"0,12 %"}],"regulatory_area_cs":"Napětí AC","search_cs":"Kalibrátory Měřicí karty Napájecí zdroje Můstky Měřiče parametrů sítě Testery elektrické bezpečnosti Zkoušečky průrazu VF generátory Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 20 Hz až 40 Hz 40 Hz až 50 Hz 40 Hz až 1 kHz 40 Hz až 1 kHz 1 kHz až 20 kHz 1 kHz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 50 Hz až 1 kHz 1 kHz až 10 kHz 10 kHz až 33 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 33 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 300 kHz až 1 MHz 300 kHz až 1 MHz 300 kHz až 1 MHz 300 kHz až 1 MHz 50 Hz až 60 Hz LMEEiO/3 LMEEiO/5 LMEEiO/28 LMEEiO/32 LMEEiO/35 LMEEiO/45","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nMěřicí karty\nNapájecí zdroje\nMůstky\nMěřiče parametrů sítě\nTestery elektrické bezpečnosti\nZkoušečky průrazu\nVF generátory"},{"_id":"fcb34ae43d5a68332bd21922","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Źródła sinusoidalnych sygnałów pomiarowych (generatory, generatory poziomu)\n- wyjście asymetryczne: od 1 mV do 1000 V (0; 50; 75; 100; 135; 150; 600) Ω\n- wyjście symetryczne: od 1 mV do 10 V (0; 100; 124; 135; 150; 600) Ω","test_object_en":"Sinusoidal measuring signal sources (generators, level generators)\n- unbalanced output: from 1 mV to 1000 V (0; 50; 75; 100; 135; 150; 600) Ω\n- balanced output: from 1 mV to 10 V (0; 100; 124; 135; 150; 600) Ω","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"20 Hz do 50 kHz","range":"1 mV","cmc":"0,16%"},{"name":"20 Hz do 50 kHz","range":"1 mV do 30 mV","cmc":"0,02%"},{"name":"20 Hz do 50 kHz","range":"0,030 V do 1000 V","cmc":"0,03%"},{"name":"50 kHz do 100 kHz","range":"1 mV","cmc":"0,25%"},{"name":"50 kHz do 100 kHz","range":"1 mV do 1000 V","cmc":"0,05%"}],"parameters_en":[{"name":"20 Hz to 50 kHz","range":"1 mV","cmc":"0,16%"},{"name":"20 Hz to 50 kHz","range":"1 mV to 30 mV","cmc":"0,02%"},{"name":"20 Hz to 50 kHz","range":"0,030 V to 1000 V","cmc":"0,03%"},{"name":"50 kHz to 100 kHz","range":"1 mV","cmc":"0,25%"},{"name":"50 kHz to 100 kHz","range":"1 mV to 1000 V","cmc":"0,05%"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n20 Hz do 50 kHz 1 mV CMC 0,16%\n20 Hz do 50 kHz 1 mV do 30 mV CMC 0,02%\n20 Hz do 50 kHz 0,030 V do 1000 V CMC 0,03%\n50 kHz do 100 kHz 1 mV CMC 0,25%\n50 kHz do 100 kHz 1 mV do 1000 V CMC 0,05%\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/10","norm_bases":["LMEEiO/10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Źródła sinusoidalnych sygnałów pomiarowych (generatory, generatory poziomu)\n- wyjście asymetryczne: od 1 mV do 1000 V (0; 50; 75; 100; 135; 150; 600) Ω\n- wyjście symetryczne: od 1 mV do 10 V (0; 100; 124; 135; 150; 600) Ω Wzorcowanie — Napięcie AC\nZakres:\n20 Hz do 50 kHz 1 mV CMC 0,16%\n20 Hz do 50 kHz 1 mV do 30 mV CMC 0,02%\n20 Hz do 50 kHz 0,030 V do 1000 V CMC 0,03%\n50 kHz do 100 kHz 1 mV CMC 0,25%\n50 kHz do 100 kHz 1 mV do 1000 V CMC 0,05%\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/10 Zrodla sinusoidalnych sygnalow pomiarowych (generatory, generatory poziomu)\n- wyjscie asymetryczne: od 1 mV do 1000 V (0; 50; 75; 100; 135; 150; 600) Ω\n- wyjscie symetryczne: od 1 mV do 10 V (0; 100; 124; 135; 150; 600) Ω Wzorcowanie — Napiecie AC\nZakres:\n20 Hz do 50 kHz 1 mV CMC 0,16%\n20 Hz do 50 kHz 1 mV do 30 mV CMC 0,02%\n20 Hz do 50 kHz 0,030 V do 1000 V CMC 0,03%\n50 kHz do 100 kHz 1 mV CMC 0,25%\n50 kHz do 100 kHz 1 mV do 1000 V CMC 0,05%\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/10","search_en":"Sinusoidal measuring signal sources (generators, level generators) - unbalanced output: from 1 mV to 1000 V (0; 50; 75; 100; 135; 150; 600) Ω - balanced output: from 1 mV to 10 V (0; 100; 124; 135; 150; 600) Ω Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) AC voltage Internal procedure Direct method At permanent location (S) 20 Hz to 50 kHz 20 Hz to 50 kHz 20 Hz to 50 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz LMEEiO/10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"20 Hz bis 50 kHz","range":"1 mV","cmc":"0,16%"},{"name":"20 Hz bis 50 kHz","range":"1 mV to 30 mV","cmc":"0,02%"},{"name":"20 Hz bis 50 kHz","range":"0,030 V to 1000 V","cmc":"0,03%"},{"name":"50 kHz bis 100 kHz","range":"1 mV","cmc":"0,25%"},{"name":"50 kHz bis 100 kHz","range":"1 mV bis 1000 V","cmc":"0,05%"}],"regulatory_area_de":"AC-Spannung","search_de":"Quellen sinusförmiger Messsignale (Generatoren, Pegelgeneratoren) - unsymmetrischer Ausgang: von 1 mV bis 1000 V (0; 50; 75; 100; 135; 150; 600) Ω - symmetrischer Ausgang: von 1 mV bis 10 V (0; 100; 124; 135; 150; 600) Ω Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) 20 Hz bis 50 kHz 20 Hz bis 50 kHz 20 Hz bis 50 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz LMEEiO/10","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Quellen sinusförmiger Messsignale (Generatoren, Pegelgeneratoren)\n- unsymmetrischer Ausgang: von 1 mV bis 1000 V (0; 50; 75; 100; 135; 150; 600) Ω\n- symmetrischer Ausgang: von 1 mV bis 10 V (0; 100; 124; 135; 150; 600) Ω","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"20 Hz 至 50 kHz","range":"1 mV","cmc":"0,16%"},{"name":"20 Hz 至 50 kHz","range":"1 mV to 30 mV","cmc":"0,02%"},{"name":"20 Hz 至 50 kHz","range":"0,030 V to 1000 V","cmc":"0,03%"},{"name":"50 kHz 至 100 kHz","range":"1 mV","cmc":"0,25%"},{"name":"50 kHz 至 100 kHz","range":"1 mV 至 1000 V","cmc":"0,05%"}],"regulatory_area_zh":"交流电压","search_zh":"正弦测量信号源（发生器、电平发生器） - 不平衡输出：1 mV 至 1000 V（0；50；75；100；135；150；600）Ω - 平衡输出：1 mV 至 10 V（0；100；124；135；150；600）Ω 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 交流电压 内部程序 直接法 在固定地点 (S) 20 Hz 至 50 kHz 20 Hz 至 50 kHz 20 Hz 至 50 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz LMEEiO/10","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"正弦测量信号源（发生器、电平发生器）\n- 不平衡输出：1 mV 至 1000 V（0；50；75；100；135；150；600）Ω\n- 平衡输出：1 mV 至 10 V（0；100；124；135；150；600）Ω","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"20 Hz až 50 kHz","range":"1 mV","cmc":"0,16%"},{"name":"20 Hz až 50 kHz","range":"1 mV to 30 mV","cmc":"0,02%"},{"name":"20 Hz až 50 kHz","range":"0,030 V to 1000 V","cmc":"0,03%"},{"name":"50 kHz až 100 kHz","range":"1 mV","cmc":"0,25%"},{"name":"50 kHz až 100 kHz","range":"1 mV do 1000 V","cmc":"0,05%"}],"regulatory_area_cs":"Napětí AC","search_cs":"Zdroje sinusových měřicích signálů (generátory, generátory úrovně) - nesymetrický výstup: od 1 mV do 1000 V (0; 50; 75; 100; 135; 150; 600) Ω - symetrický výstup: od 1 mV do 10 V (0; 100; 124; 135; 150; 600) Ω Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Napětí AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) 20 Hz až 50 kHz 20 Hz až 50 kHz 20 Hz až 50 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz LMEEiO/10","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Zdroje sinusových měřicích signálů (generátory, generátory úrovně)\n- nesymetrický výstup: od 1 mV do 1000 V (0; 50; 75; 100; 135; 150; 600) Ω\n- symetrický výstup: od 1 mV do 10 V (0; 100; 124; 135; 150; 600) Ω"},{"_id":"d6228218639c317a37106260","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Multimetry\nMierniki napięcia cyfrowe\nMierniki napięcia analogowe\nKarty pomiarowe\nSkopometry\nMierniki parametrów sieci\nTestery bezpieczeństwa elektrycznego\nDzielniki napięcia\nSondy pomiarowe\nMierniki mocy w.cz.\nTestery radiokomunikacyjne\nObciążenia elektroniczne\nAnalizatory parametrów i uszkodzeń linii","test_object_en":"Multimeters\nDigital voltmeters\nAnalogue voltmeters\nData acquisition cards\nScopemeters\nPower network parameter meters\nElectrical safety testers\nVoltage dividers\nMeasuring probes\nRF power meters\nRadio communication testers\nElectronic loads\nLine parameter and fault analysers","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"10 Hz do 40 Hz","range":"0,1 mV do 5 mV","cmc":"3,5·10⁻⁴ · U + 3,5 µV"},{"name":"10 Hz do 40 Hz","range":"5 mV do 12 mV","cmc":"1,5·10⁻⁴ · U + 4,7 µV"},{"name":"10 Hz do 40 Hz","range":"12 mV do 120 mV","cmc":"8·10⁻⁵ · U + 4,7 µ"},{"name":"10 Hz do 40 Hz","range":"0,12 V do 1,2 V","cmc":"8·10⁻⁵ · U + 47 µV"},{"name":"10 Hz do 40 Hz","range":"1,2 V do 12 V","cmc":"8·10⁻⁵ · U + 0,47 m"},{"name":"10 Hz do 40 Hz","range":"12 V do 20 V","cmc":"1,2·10⁻⁴ · U + 0,32 mV"},{"name":"10 Hz do 40 Hz","range":"20 V do 200V","cmc":"1,2·10⁻⁴ · U + 2,5 mV"},{"name":"10 Hz do 40 Hz","range":"200 V do 1000 V","cmc":"1,3·10⁻⁴ · U + 23 mV"},{"name":"20 Hz do 40 Hz","range":"0,22 V do 2,2 V","cmc":"8·10⁻⁵ · U + 22 µV"},{"name":"40 Hz do 50 Hz","range":"200 V do 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"40 Hz do 1 kHz","range":"0,1 mV do 12 mV","cmc":"2,4·10⁻⁴ · U + 1,3 µV"},{"name":"40 Hz do 1 kHz","range":"12 mV do 120 mV","cmc":"8,2·10⁻⁵ · U + 2,3 µV"},{"name":"40 Hz do 20 kHz","range":"120 mV do 220 mV","cmc":"6,7·10⁻⁵ · U + 8,1 µV"},{"name":"40 Hz do 20 kHz","range":"0,22 V do 2,2 V","cmc":"4,2·10⁻⁵ · U + 12 µV"},{"name":"40 Hz do 20 kHz","range":"2,2 V do 22 V","cmc":"5,0·10⁻⁵ · U + 60 µV"},{"name":"40 Hz do 20 kHz","range":"22 V do 220 V","cmc":"6,0·10⁻⁵ · U + 0,8 mV"},{"name":"50 Hz do 1 kHz","range":"220 V do 1000 V","cmc":"8,0·10⁻⁵ · U + 4,5 mV"},{"name":"1 kHz do 10 kHz","range":"220 V do 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"1 kHz do 20 kHz","range":"0,1 mV do 12 mV","cmc":"3,5·10⁻⁴ · U + 1,3 µV"},{"name":"1 kHz do 20 kHz","range":"12 mV do 120 mV","cmc":"1,2·10⁻⁴ · U + 4,6 µV"},{"name":"10 kHz do 33 kHz","range":"220 V do 1000 V","cmc":"1,9·10⁻⁴ · U + 21 mV"},{"name":"20 kHz do 50 kHz","range":"0,1 mV do 2,2 mV","cmc":"3,0·10⁻⁴ · U + 4,6 µV"},{"name":"20 kHz do 50 kHz","range":"2,2 mV do 22 mV","cmc":"2,3·10⁻⁴ · U + 4,7 µV"},{"name":"20 kHz do 50 kHz","range":"22 mV do 220 mV","cmc":"1,4·10⁻⁵ · U + 9 µV"},{"name":"20 kHz do 50 kHz","range":"0,22 V do 2,2 V","cmc":"7,6·10⁻⁵ · U + 13 µV"},{"name":"20 kHz do 50 kHz","range":"2,2 V do 22 V","cmc":"7,8·10⁻⁵ · U + 0,12 mV"},{"name":"20 kHz do 50 kHz","range":"22 V do 220 V","cmc":"9,2·10⁻⁵ · U + 1,2 mV"},{"name":"33 kHz do 100 kHz","range":"220 V do 750 V","cmc":"6,0·10⁻⁴ · U + 0,23 V"},{"name":"50 kHz do 100 kHz","range":"0,1 mV do 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"50 kHz do 100 kHz","range":"2,2 mV do 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"50 kHz do 100 kHz","range":"22 mV do 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"50 kHz do 100 kHz","range":"0,22 V do 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"50 kHz do 100 kHz","range":"2,2 V do 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"50 kHz do 100 kHz","range":"22 V do 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"100 kHz do 300 kHz","range":"0,1 mV do 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"100 kHz do 300 kHz","range":"2,2 mV do 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"100 kHz do 300 kHz","range":"22 mV do 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"100 kHz do 300 kHz","range":"0,22 V do 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"100 kHz do 300 kHz","range":"2,2 V do 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"100 kHz do 300 kHz","range":"22 V do 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"300 kHz do 1 MHz","range":"2,2 mV do 22 mV","cmc":"3,1·10⁻³ · U + 24 µV"},{"name":"300 kHz do 1 MHz","range":"22 mV do 220 mV","cmc":"3,1·10⁻³ · U + 56 µV"},{"name":"300 kHz do 1 MHz","range":"0,22 V do 2,2 V","cmc":"2,0·10⁻³ · U + 0,34 mV"},{"name":"300 kHz do 1 MHz","range":"2,2 V do 22 V","cmc":"1,8·10⁻³ · U + 3,5 mV"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"0,1 mV to 5 mV","cmc":"3,5·10⁻⁴ · U + 3,5 µV"},{"name":"10 Hz to 40 Hz","range":"5 mV to 12 mV","cmc":"1,5·10⁻⁴ · U + 4,7 µV"},{"name":"10 Hz to 40 Hz","range":"12 mV to 120 mV","cmc":"8·10⁻⁵ · U + 4,7 µ"},{"name":"10 Hz to 40 Hz","range":"0,12 V to 1,2 V","cmc":"8·10⁻⁵ · U + 47 µV"},{"name":"10 Hz to 40 Hz","range":"1,2 V to 12 V","cmc":"8·10⁻⁵ · U + 0,47 m"},{"name":"10 Hz to 40 Hz","range":"12 V to 20 V","cmc":"1,2·10⁻⁴ · U + 0,32 mV"},{"name":"10 Hz to 40 Hz","range":"20 V to 200V","cmc":"1,2·10⁻⁴ · U + 2,5 mV"},{"name":"10 Hz to 40 Hz","range":"200 V to 1000 V","cmc":"1,3·10⁻⁴ · U + 23 mV"},{"name":"20 Hz to 40 Hz","range":"0,22 V to 2,2 V","cmc":"8·10⁻⁵ · U + 22 µV"},{"name":"40 Hz to 50 Hz","range":"200 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"40 Hz to 1 kHz","range":"0,1 mV to 12 mV","cmc":"2,4·10⁻⁴ · U + 1,3 µV"},{"name":"40 Hz to 1 kHz","range":"12 mV to 120 mV","cmc":"8,2·10⁻⁵ · U + 2,3 µV"},{"name":"40 Hz to 20 kHz","range":"120 mV to 220 mV","cmc":"6,7·10⁻⁵ · U + 8,1 µV"},{"name":"40 Hz to 20 kHz","range":"0,22 V to 2,2 V","cmc":"4,2·10⁻⁵ · U + 12 µV"},{"name":"40 Hz to 20 kHz","range":"2,2 V to 22 V","cmc":"5,0·10⁻⁵ · U + 60 µV"},{"name":"40 Hz to 20 kHz","range":"22 V to 220 V","cmc":"6,0·10⁻⁵ · U + 0,8 mV"},{"name":"50 Hz to 1 kHz","range":"220 V to 1000 V","cmc":"8,0·10⁻⁵ · U + 4,5 mV"},{"name":"1 kHz to 10 kHz","range":"220 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"1 kHz to 20 kHz","range":"0,1 mV to 12 mV","cmc":"3,5·10⁻⁴ · U + 1,3 µV"},{"name":"1 kHz to 20 kHz","range":"12 mV to 120 mV","cmc":"1,2·10⁻⁴ · U + 4,6 µV"},{"name":"10 kHz to 33 kHz","range":"220 V to 1000 V","cmc":"1,9·10⁻⁴ · U + 21 mV"},{"name":"20 kHz to 50 kHz","range":"0,1 mV to 2,2 mV","cmc":"3,0·10⁻⁴ · U + 4,6 µV"},{"name":"20 kHz to 50 kHz","range":"2,2 mV to 22 mV","cmc":"2,3·10⁻⁴ · U + 4,7 µV"},{"name":"20 kHz to 50 kHz","range":"22 mV to 220 mV","cmc":"1,4·10⁻⁵ · U + 9 µV"},{"name":"20 kHz to 50 kHz","range":"0,22 V to 2,2 V","cmc":"7,6·10⁻⁵ · U + 13 µV"},{"name":"20 kHz to 50 kHz","range":"2,2 V to 22 V","cmc":"7,8·10⁻⁵ · U + 0,12 mV"},{"name":"20 kHz to 50 kHz","range":"22 V to 220 V","cmc":"9,2·10⁻⁵ · U + 1,2 mV"},{"name":"33 kHz to 100 kHz","range":"220 V to 750 V","cmc":"6,0·10⁻⁴ · U + 0,23 V"},{"name":"50 kHz to 100 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"50 kHz to 100 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"50 kHz to 100 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"50 kHz to 100 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"50 kHz to 100 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"50 kHz to 100 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"100 kHz to 300 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"100 kHz to 300 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"100 kHz to 300 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"100 kHz to 300 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"100 kHz to 300 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"100 kHz to 300 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"300 kHz to 1 MHz","range":"2,2 mV to 22 mV","cmc":"3,1·10⁻³ · U + 24 µV"},{"name":"300 kHz to 1 MHz","range":"22 mV to 220 mV","cmc":"3,1·10⁻³ · U + 56 µV"},{"name":"300 kHz to 1 MHz","range":"0,22 V to 2,2 V","cmc":"2,0·10⁻³ · U + 0,34 mV"},{"name":"300 kHz to 1 MHz","range":"2,2 V to 22 V","cmc":"1,8·10⁻³ · U + 3,5 mV"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 40 Hz 0,1 mV do 5 mV CMC 3,5·10⁻⁴ · U + 3,5 µV\n10 Hz do 40 Hz 5 mV do 12 mV CMC 1,5·10⁻⁴ · U + 4,7 µV\n10 Hz do 40 Hz 12 mV do 120 mV CMC 8·10⁻⁵ · U + 4,7 µ\n10 Hz do 40 Hz 0,12 V do 1,2 V CMC 8·10⁻⁵ · U + 47 µV\n10 Hz do 40 Hz 1,2 V do 12 V CMC 8·10⁻⁵ · U + 0,47 m\n10 Hz do 40 Hz 12 V do 20 V CMC 1,2·10⁻⁴ · U + 0,32 mV\n10 Hz do 40 Hz 20 V do 200V CMC 1,2·10⁻⁴ · U + 2,5 mV\n10 Hz do 40 Hz 200 V do 1000 V CMC 1,3·10⁻⁴ · U + 23 mV\n20 Hz do 40 Hz 0,22 V do 2,2 V CMC 8·10⁻⁵ · U + 22 µV\n40 Hz do 50 Hz 200 V do 1000 V CMC 1,1·10⁻⁴ · U + 23 mV\n40 Hz do 1 kHz 0,1 mV do 12 mV CMC 2,4·10⁻⁴ · U + 1,3 µV\n40 Hz do 1 kHz 12 mV do 120 mV CMC 8,2·10⁻⁵ · U + 2,3 µV\n40 Hz do 20 kHz 120 mV do 220 mV CMC 6,7·10⁻⁵ · U + 8,1 µV\n40 Hz do 20 kHz 0,22 V do 2,2 V CMC 4,2·10⁻⁵ · U + 12 µV\n40 Hz do 20 kHz 2,2 V do 22 V CMC 5,0·10⁻⁵ · U + 60 µV\n40 Hz do 20 kHz 22 V do 220 V CMC 6,0·10⁻⁵ · U + 0,8 mV\n50 Hz do 1 kHz 220 V do 1000 V CMC 8,0·10⁻⁵ · U + 4,5 mV\n1 kHz do 10 kHz 220 V do 1000 V CMC 1,1·10⁻⁴ · U + 23 mV\n1 kHz do 20 kHz 0,1 mV do 12 mV CMC 3,5·10⁻⁴ · U + 1,3 µV\n1 kHz do 20 kHz 12 mV do 120 mV CMC 1,2·10⁻⁴ · U + 4,6 µV\n10 kHz do 33 kHz 220 V do 1000 V CMC 1,9·10⁻⁴ · U + 21 mV\n20 kHz do 50 kHz 0,1 mV do 2,2 mV CMC 3,0·10⁻⁴ · U + 4,6 µV\n20 kHz do 50 kHz 2,2 mV do 22 mV CMC 2,3·10⁻⁴ · U + 4,7 µV\n20 kHz do 50 kHz 22 mV do 220 mV CMC 1,4·10⁻⁵ · U + 9 µV\n20 kHz do 50 kHz 0,22 V do 2,2 V CMC 7,6·10⁻⁵ · U + 13 µV\n20 kHz do 50 kHz 2,2 V do 22 V CMC 7,8·10⁻⁵ · U + 0,12 mV\n20 kHz do 50 kHz 22 V do 220 V CMC 9,2·10⁻⁵ · U + 1,2 mV\n33 kHz do 100 kHz 220 V do 750 V CMC 6,0·10⁻⁴ · U + 0,23 V\n50 kHz do 100 kHz 0,1 mV do 2,2 mV CMC 5,0·10⁻⁴ · U + 6 µV\n50 kHz do 100 kHz 2,2 mV do 22 mV CMC 6,0·10⁻⁴ · U + 5,7 µV\n50 kHz do 100 kHz 22 mV do 220 mV CMC 3,6·10⁻⁴ · U + 20 µV\n50 kHz do 100 kHz 0,22 V do 2,2 V CMC 1,0·10⁻⁴ · U + 34 µV\n50 kHz do 100 kHz 2,2 V do 22 V CMC 9,5·10⁻⁵ · U + 0,23 mV\n50 kHz do 100 kHz 22 V do 220 V CMC 1,8·10⁻⁴ · U + 2,7 mV\n100 kHz do 300 kHz 0,1 mV do 2,2 mV CMC 5,0·10⁻⁴ · U + 6 µV\n100 kHz do 300 kHz 2,2 mV do 22 mV CMC 6,0·10⁻⁴ · U + 5,7 µV\n100 kHz do 300 kHz 22 mV do 220 mV CMC 3,6·10⁻⁴ · U + 20 µV\n100 kHz do 300 kHz 0,22 V do 2,2 V CMC 1,0·10⁻⁴ · U + 34 µV\n100 kHz do 300 kHz 2,2 V do 22 V CMC 9,5·10⁻⁵ · U + 0,23 mV\n100 kHz do 300 kHz 22 V do 220 V CMC 1,8·10⁻⁴ · U + 2,7 mV\n300 kHz do 1 MHz 2,2 mV do 22 mV CMC 3,1·10⁻³ · U + 24 µV\n300 kHz do 1 MHz 22 mV do 220 mV CMC 3,1·10⁻³ · U + 56 µV\n300 kHz do 1 MHz 0,22 V do 2,2 V CMC 2,0·10⁻³ · U + 0,34 mV\n300 kHz do 1 MHz 2,2 V do 22 V CMC 1,8·10⁻³ · U + 3,5 mV\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","norm_bases":["LMEEiO/2","EURAMET cg-15 v. 3.0","LMEEiO/33","LMEEiO/35","LMEEiO/42","LMEEiO/45","LMEEiO/53"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V). Analizatory parametrów i uszkodzeń linii — wyłącznie w stałej lokalizacji (S)","note_en":"U – measured value (V). Line parameter and fault analysers — at permanent location only (S)","search_text":"Multimetry\nMierniki napięcia cyfrowe\nMierniki napięcia analogowe\nKarty pomiarowe\nSkopometry\nMierniki parametrów sieci\nTestery bezpieczeństwa elektrycznego\nDzielniki napięcia\nSondy pomiarowe\nMierniki mocy w.cz.\nTestery radiokomunikacyjne\nObciążenia elektroniczne\nAnalizatory parametrów i uszkodzeń linii Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 40 Hz 0,1 mV do 5 mV CMC 3,5·10⁻⁴ · U + 3,5 µV\n10 Hz do 40 Hz 5 mV do 12 mV CMC 1,5·10⁻⁴ · U + 4,7 µV\n10 Hz do 40 Hz 12 mV do 120 mV CMC 8·10⁻⁵ · U + 4,7 µ\n10 Hz do 40 Hz 0,12 V do 1,2 V CMC 8·10⁻⁵ · U + 47 µV\n10 Hz do 40 Hz 1,2 V do 12 V CMC 8·10⁻⁵ · U + 0,47 m\n10 Hz do 40 Hz 12 V do 20 V CMC 1,2·10⁻⁴ · U + 0,32 mV\n10 Hz do 40 Hz 20 V do 200V CMC 1,2·10⁻⁴ · U + 2,5 mV\n10 Hz do 40 Hz 200 V do 1000 V CMC 1,3·10⁻⁴ · U + 23 mV\n20 Hz do 40 Hz 0,22 V do 2,2 V CMC 8·10⁻⁵ · U + 22 µV\n40 Hz do 50 Hz 200 V do 1000 V CMC 1,1·10⁻⁴ · U + 23 mV\n40 Hz do 1 kHz 0,1 mV do 12 mV CMC 2,4·10⁻⁴ · U + 1,3 µV\n40 Hz do 1 kHz 12 mV do 120 mV CMC 8,2·10⁻⁵ · U + 2,3 µV\n40 Hz do 20 kHz 120 mV do 220 mV CMC 6,7·10⁻⁵ · U + 8,1 µV\n40 Hz do 20 kHz 0,22 V do 2,2 V CMC 4,2·10⁻⁵ · U + 12 µV\n40 Hz do 20 kHz 2,2 V do 22 V CMC 5,0·10⁻⁵ · U + 60 µV\n40 Hz do 20 kHz 22 V do 220 V CMC 6,0·10⁻⁵ · U + 0,8 mV\n50 Hz do 1 kHz 220 V do 1000 V CMC 8,0·10⁻⁵ · U + 4,5 mV\n1 kHz do 10 kHz 220 V do 1000 V CMC 1,1·10⁻⁴ · U + 23 mV\n1 kHz do 20 kHz 0,1 mV do 12 mV CMC 3,5·10⁻⁴ · U + 1,3 µV\n1 kHz do 20 kHz 12 mV do 120 mV CMC 1,2·10⁻⁴ · U + 4,6 µV\n10 kHz do 33 kHz 220 V do 1000 V CMC 1,9·10⁻⁴ · U + 21 mV\n20 kHz do 50 kHz 0,1 mV do 2,2 mV CMC 3,0·10⁻⁴ · U + 4,6 µV\n20 kHz do 50 kHz 2,2 mV do 22 mV CMC 2,3·10⁻⁴ · U + 4,7 µV\n20 kHz do 50 kHz 22 mV do 220 mV CMC 1,4·10⁻⁵ · U + 9 µV\n20 kHz do 50 kHz 0,22 V do 2,2 V CMC 7,6·10⁻⁵ · U + 13 µV\n20 kHz do 50 kHz 2,2 V do 22 V CMC 7,8·10⁻⁵ · U + 0,12 mV\n20 kHz do 50 kHz 22 V do 220 V CMC 9,2·10⁻⁵ · U + 1,2 mV\n33 kHz do 100 kHz 220 V do 750 V CMC 6,0·10⁻⁴ · U + 0,23 V\n50 kHz do 100 kHz 0,1 mV do 2,2 mV CMC 5,0·10⁻⁴ · U + 6 µV\n50 kHz do 100 kHz 2,2 mV do 22 mV CMC 6,0·10⁻⁴ · U + 5,7 µV\n50 kHz do 100 kHz 22 mV do 220 mV CMC 3,6·10⁻⁴ · U + 20 µV\n50 kHz do 100 kHz 0,22 V do 2,2 V CMC 1,0·10⁻⁴ · U + 34 µV\n50 kHz do 100 kHz 2,2 V do 22 V CMC 9,5·10⁻⁵ · U + 0,23 mV\n50 kHz do 100 kHz 22 V do 220 V CMC 1,8·10⁻⁴ · U + 2,7 mV\n100 kHz do 300 kHz 0,1 mV do 2,2 mV CMC 5,0·10⁻⁴ · U + 6 µV\n100 kHz do 300 kHz 2,2 mV do 22 mV CMC 6,0·10⁻⁴ · U + 5,7 µV\n100 kHz do 300 kHz 22 mV do 220 mV CMC 3,6·10⁻⁴ · U + 20 µV\n100 kHz do 300 kHz 0,22 V do 2,2 V CMC 1,0·10⁻⁴ · U + 34 µV\n100 kHz do 300 kHz 2,2 V do 22 V CMC 9,5·10⁻⁵ · U + 0,23 mV\n100 kHz do 300 kHz 22 V do 220 V CMC 1,8·10⁻⁴ · U + 2,7 mV\n300 kHz do 1 MHz 2,2 mV do 22 mV CMC 3,1·10⁻³ · U + 24 µV\n300 kHz do 1 MHz 22 mV do 220 mV CMC 3,1·10⁻³ · U + 56 µV\n300 kHz do 1 MHz 0,22 V do 2,2 V CMC 2,0·10⁻³ · U + 0,34 mV\n300 kHz do 1 MHz 2,2 V do 22 V CMC 1,8·10⁻³ · U + 3,5 mV\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53 Multimetry\nMierniki napiecia cyfrowe\nMierniki napiecia analogowe\nKarty pomiarowe\nSkopometry\nMierniki parametrow sieci\nTestery bezpieczenstwa elektrycznego\nDzielniki napiecia\nSondy pomiarowe\nMierniki mocy w.cz.\nTestery radiokomunikacyjne\nObciazenia elektroniczne\nAnalizatory parametrow i uszkodzen linii Wzorcowanie — Napiecie AC\nZakres:\n10 Hz do 40 Hz 0,1 mV do 5 mV CMC 3,5·10⁻⁴ · U + 3,5 µV\n10 Hz do 40 Hz 5 mV do 12 mV CMC 1,5·10⁻⁴ · U + 4,7 µV\n10 Hz do 40 Hz 12 mV do 120 mV CMC 8·10⁻⁵ · U + 4,7 µ\n10 Hz do 40 Hz 0,12 V do 1,2 V CMC 8·10⁻⁵ · U + 47 µV\n10 Hz do 40 Hz 1,2 V do 12 V CMC 8·10⁻⁵ · U + 0,47 m\n10 Hz do 40 Hz 12 V do 20 V CMC 1,2·10⁻⁴ · U + 0,32 mV\n10 Hz do 40 Hz 20 V do 200V CMC 1,2·10⁻⁴ · U + 2,5 mV\n10 Hz do 40 Hz 200 V do 1000 V CMC 1,3·10⁻⁴ · U + 23 mV\n20 Hz do 40 Hz 0,22 V do 2,2 V CMC 8·10⁻⁵ · U + 22 µV\n40 Hz do 50 Hz 200 V do 1000 V CMC 1,1·10⁻⁴ · U + 23 mV\n40 Hz do 1 kHz 0,1 mV do 12 mV CMC 2,4·10⁻⁴ · U + 1,3 µV\n40 Hz do 1 kHz 12 mV do 120 mV CMC 8,2·10⁻⁵ · U + 2,3 µV\n40 Hz do 20 kHz 120 mV do 220 mV CMC 6,7·10⁻⁵ · U + 8,1 µV\n40 Hz do 20 kHz 0,22 V do 2,2 V CMC 4,2·10⁻⁵ · U + 12 µV\n40 Hz do 20 kHz 2,2 V do 22 V CMC 5,0·10⁻⁵ · U + 60 µV\n40 Hz do 20 kHz 22 V do 220 V CMC 6,0·10⁻⁵ · U + 0,8 mV\n50 Hz do 1 kHz 220 V do 1000 V CMC 8,0·10⁻⁵ · U + 4,5 mV\n1 kHz do 10 kHz 220 V do 1000 V CMC 1,1·10⁻⁴ · U + 23 mV\n1 kHz do 20 kHz 0,1 mV do 12 mV CMC 3,5·10⁻⁴ · U + 1,3 µV\n1 kHz do 20 kHz 12 mV do 120 mV CMC 1,2·10⁻⁴ · U + 4,6 µV\n10 kHz do 33 kHz 220 V do 1000 V CMC 1,9·10⁻⁴ · U + 21 mV\n20 kHz do 50 kHz 0,1 mV do 2,2 mV CMC 3,0·10⁻⁴ · U + 4,6 µV\n20 kHz do 50 kHz 2,2 mV do 22 mV CMC 2,3·10⁻⁴ · U + 4,7 µV\n20 kHz do 50 kHz 22 mV do 220 mV CMC 1,4·10⁻⁵ · U + 9 µV\n20 kHz do 50 kHz 0,22 V do 2,2 V CMC 7,6·10⁻⁵ · U + 13 µV\n20 kHz do 50 kHz 2,2 V do 22 V CMC 7,8·10⁻⁵ · U + 0,12 mV\n20 kHz do 50 kHz 22 V do 220 V CMC 9,2·10⁻⁵ · U + 1,2 mV\n33 kHz do 100 kHz 220 V do 750 V CMC 6,0·10⁻⁴ · U + 0,23 V\n50 kHz do 100 kHz 0,1 mV do 2,2 mV CMC 5,0·10⁻⁴ · U + 6 µV\n50 kHz do 100 kHz 2,2 mV do 22 mV CMC 6,0·10⁻⁴ · U + 5,7 µV\n50 kHz do 100 kHz 22 mV do 220 mV CMC 3,6·10⁻⁴ · U + 20 µV\n50 kHz do 100 kHz 0,22 V do 2,2 V CMC 1,0·10⁻⁴ · U + 34 µV\n50 kHz do 100 kHz 2,2 V do 22 V CMC 9,5·10⁻⁵ · U + 0,23 mV\n50 kHz do 100 kHz 22 V do 220 V CMC 1,8·10⁻⁴ · U + 2,7 mV\n100 kHz do 300 kHz 0,1 mV do 2,2 mV CMC 5,0·10⁻⁴ · U + 6 µV\n100 kHz do 300 kHz 2,2 mV do 22 mV CMC 6,0·10⁻⁴ · U + 5,7 µV\n100 kHz do 300 kHz 22 mV do 220 mV CMC 3,6·10⁻⁴ · U + 20 µV\n100 kHz do 300 kHz 0,22 V do 2,2 V CMC 1,0·10⁻⁴ · U + 34 µV\n100 kHz do 300 kHz 2,2 V do 22 V CMC 9,5·10⁻⁵ · U + 0,23 mV\n100 kHz do 300 kHz 22 V do 220 V CMC 1,8·10⁻⁴ · U + 2,7 mV\n300 kHz do 1 MHz 2,2 mV do 22 mV CMC 3,1·10⁻³ · U + 24 µV\n300 kHz do 1 MHz 22 mV do 220 mV CMC 3,1·10⁻³ · U + 56 µV\n300 kHz do 1 MHz 0,22 V do 2,2 V CMC 2,0·10⁻³ · U + 0,34 mV\n300 kHz do 1 MHz 2,2 V do 22 V CMC 1,8·10⁻³ · U + 3,5 mV\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","search_en":"Multimeters Digital voltmeters Analogue voltmeters Data acquisition cards Scopemeters Power network parameter meters Electrical safety testers Voltage dividers Measuring probes RF power meters Radio communication testers Electronic loads Line parameter and fault analysers Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC voltage Internal procedure Direct method At permanent location (S) and outside of it (P) 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 20 Hz to 40 Hz 40 Hz to 50 Hz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 50 Hz to 1 kHz 1 kHz to 10 kHz 1 kHz to 20 kHz 1 kHz to 20 kHz 10 kHz to 33 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 33 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 300 kHz to 1 MHz 300 kHz to 1 MHz 300 kHz to 1 MHz 300 kHz to 1 MHz LMEEiO/2 based on EURAMET cg-15 v. 3.0 LMEEiO/33 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/2 based on EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"10 Hz bis 40 Hz","range":"0,1 mV to 5 mV","cmc":"3,5·10⁻⁴ · U + 3,5 µV"},{"name":"10 Hz bis 40 Hz","range":"5 mV to 12 mV","cmc":"1,5·10⁻⁴ · U + 4,7 µV"},{"name":"10 Hz bis 40 Hz","range":"12 mV to 120 mV","cmc":"8·10⁻⁵ · U + 4,7 µ"},{"name":"10 Hz bis 40 Hz","range":"0,12 V to 1,2 V","cmc":"8·10⁻⁵ · U + 47 µV"},{"name":"10 Hz bis 40 Hz","range":"1,2 V to 12 V","cmc":"8·10⁻⁵ · U + 0,47 m"},{"name":"10 Hz bis 40 Hz","range":"12 V to 20 V","cmc":"1,2·10⁻⁴ · U + 0,32 mV"},{"name":"10 Hz bis 40 Hz","range":"20 V to 200V","cmc":"1,2·10⁻⁴ · U + 2,5 mV"},{"name":"10 Hz bis 40 Hz","range":"200 V to 1000 V","cmc":"1,3·10⁻⁴ · U + 23 mV"},{"name":"20 Hz bis 40 Hz","range":"0,22 V to 2,2 V","cmc":"8·10⁻⁵ · U + 22 µV"},{"name":"40 Hz bis 50 Hz","range":"200 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"40 Hz bis 1 kHz","range":"0,1 mV to 12 mV","cmc":"2,4·10⁻⁴ · U + 1,3 µV"},{"name":"40 Hz bis 1 kHz","range":"12 mV to 120 mV","cmc":"8,2·10⁻⁵ · U + 2,3 µV"},{"name":"40 Hz bis 20 kHz","range":"120 mV to 220 mV","cmc":"6,7·10⁻⁵ · U + 8,1 µV"},{"name":"40 Hz bis 20 kHz","range":"0,22 V to 2,2 V","cmc":"4,2·10⁻⁵ · U + 12 µV"},{"name":"40 Hz bis 20 kHz","range":"2,2 V to 22 V","cmc":"5,0·10⁻⁵ · U + 60 µV"},{"name":"40 Hz bis 20 kHz","range":"22 V to 220 V","cmc":"6,0·10⁻⁵ · U + 0,8 mV"},{"name":"50 Hz bis 1 kHz","range":"220 V to 1000 V","cmc":"8,0·10⁻⁵ · U + 4,5 mV"},{"name":"1 kHz bis 10 kHz","range":"220 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"1 kHz bis 20 kHz","range":"0,1 mV to 12 mV","cmc":"3,5·10⁻⁴ · U + 1,3 µV"},{"name":"1 kHz bis 20 kHz","range":"12 mV to 120 mV","cmc":"1,2·10⁻⁴ · U + 4,6 µV"},{"name":"10 kHz bis 33 kHz","range":"220 V to 1000 V","cmc":"1,9·10⁻⁴ · U + 21 mV"},{"name":"20 kHz bis 50 kHz","range":"0,1 mV to 2,2 mV","cmc":"3,0·10⁻⁴ · U + 4,6 µV"},{"name":"20 kHz bis 50 kHz","range":"2,2 mV to 22 mV","cmc":"2,3·10⁻⁴ · U + 4,7 µV"},{"name":"20 kHz bis 50 kHz","range":"22 mV to 220 mV","cmc":"1,4·10⁻⁵ · U + 9 µV"},{"name":"20 kHz bis 50 kHz","range":"0,22 V to 2,2 V","cmc":"7,6·10⁻⁵ · U + 13 µV"},{"name":"20 kHz bis 50 kHz","range":"2,2 V to 22 V","cmc":"7,8·10⁻⁵ · U + 0,12 mV"},{"name":"20 kHz bis 50 kHz","range":"22 V to 220 V","cmc":"9,2·10⁻⁵ · U + 1,2 mV"},{"name":"33 kHz bis 100 kHz","range":"220 V to 750 V","cmc":"6,0·10⁻⁴ · U + 0,23 V"},{"name":"50 kHz bis 100 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"50 kHz bis 100 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"50 kHz bis 100 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"50 kHz bis 100 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"50 kHz bis 100 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"50 kHz bis 100 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"100 kHz bis 300 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"100 kHz bis 300 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"100 kHz bis 300 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"100 kHz bis 300 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"100 kHz bis 300 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"100 kHz bis 300 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"300 kHz bis 1 MHz","range":"2,2 mV to 22 mV","cmc":"3,1·10⁻³ · U + 24 µV"},{"name":"300 kHz bis 1 MHz","range":"22 mV to 220 mV","cmc":"3,1·10⁻³ · U + 56 µV"},{"name":"300 kHz bis 1 MHz","range":"0,22 V to 2,2 V","cmc":"2,0·10⁻³ · U + 0,34 mV"},{"name":"300 kHz bis 1 MHz","range":"2,2 V to 22 V","cmc":"1,8·10⁻³ · U + 3,5 mV"}],"reference_de":"LMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","regulatory_area_de":"AC-Spannung","search_de":"Multimeter Digitale Spannungsmessgeräte Analoge Spannungsmessgeräte Messkarten Scopemeter Netzparametermessgeräte Prüfgeräte für elektrische Sicherheit Spannungsteiler Messsonden HF-Leistungsmesser Funkkommunikationstester Elektronische Lasten Leitungsparameter- und Fehleranalysatoren Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 20 Hz bis 40 Hz 40 Hz bis 50 Hz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 50 Hz bis 1 kHz 1 kHz bis 10 kHz 1 kHz bis 20 kHz 1 kHz bis 20 kHz 10 kHz bis 33 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 33 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 300 kHz bis 1 MHz 300 kHz bis 1 MHz 300 kHz bis 1 MHz 300 kHz bis 1 MHz LMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0 LMEEiO/33 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Multimeter\nDigitale Spannungsmessgeräte\nAnaloge Spannungsmessgeräte\nMesskarten\nScopemeter\nNetzparametermessgeräte\nPrüfgeräte für elektrische Sicherheit\nSpannungsteiler\nMesssonden\nHF-Leistungsmesser\nFunkkommunikationstester\nElektronische Lasten\nLeitungsparameter- und Fehleranalysatoren","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"0,1 mV to 5 mV","cmc":"3,5·10⁻⁴ · U + 3,5 µV"},{"name":"10 Hz 至 40 Hz","range":"5 mV to 12 mV","cmc":"1,5·10⁻⁴ · U + 4,7 µV"},{"name":"10 Hz 至 40 Hz","range":"12 mV to 120 mV","cmc":"8·10⁻⁵ · U + 4,7 µ"},{"name":"10 Hz 至 40 Hz","range":"0,12 V to 1,2 V","cmc":"8·10⁻⁵ · U + 47 µV"},{"name":"10 Hz 至 40 Hz","range":"1,2 V to 12 V","cmc":"8·10⁻⁵ · U + 0,47 m"},{"name":"10 Hz 至 40 Hz","range":"12 V to 20 V","cmc":"1,2·10⁻⁴ · U + 0,32 mV"},{"name":"10 Hz 至 40 Hz","range":"20 V to 200V","cmc":"1,2·10⁻⁴ · U + 2,5 mV"},{"name":"10 Hz 至 40 Hz","range":"200 V to 1000 V","cmc":"1,3·10⁻⁴ · U + 23 mV"},{"name":"20 Hz 至 40 Hz","range":"0,22 V to 2,2 V","cmc":"8·10⁻⁵ · U + 22 µV"},{"name":"40 Hz 至 50 Hz","range":"200 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"40 Hz 至 1 kHz","range":"0,1 mV to 12 mV","cmc":"2,4·10⁻⁴ · U + 1,3 µV"},{"name":"40 Hz 至 1 kHz","range":"12 mV to 120 mV","cmc":"8,2·10⁻⁵ · U + 2,3 µV"},{"name":"40 Hz 至 20 kHz","range":"120 mV to 220 mV","cmc":"6,7·10⁻⁵ · U + 8,1 µV"},{"name":"40 Hz 至 20 kHz","range":"0,22 V to 2,2 V","cmc":"4,2·10⁻⁵ · U + 12 µV"},{"name":"40 Hz 至 20 kHz","range":"2,2 V to 22 V","cmc":"5,0·10⁻⁵ · U + 60 µV"},{"name":"40 Hz 至 20 kHz","range":"22 V to 220 V","cmc":"6,0·10⁻⁵ · U + 0,8 mV"},{"name":"50 Hz 至 1 kHz","range":"220 V to 1000 V","cmc":"8,0·10⁻⁵ · U + 4,5 mV"},{"name":"1 kHz 至 10 kHz","range":"220 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"1 kHz 至 20 kHz","range":"0,1 mV to 12 mV","cmc":"3,5·10⁻⁴ · U + 1,3 µV"},{"name":"1 kHz 至 20 kHz","range":"12 mV to 120 mV","cmc":"1,2·10⁻⁴ · U + 4,6 µV"},{"name":"10 kHz 至 33 kHz","range":"220 V to 1000 V","cmc":"1,9·10⁻⁴ · U + 21 mV"},{"name":"20 kHz 至 50 kHz","range":"0,1 mV to 2,2 mV","cmc":"3,0·10⁻⁴ · U + 4,6 µV"},{"name":"20 kHz 至 50 kHz","range":"2,2 mV to 22 mV","cmc":"2,3·10⁻⁴ · U + 4,7 µV"},{"name":"20 kHz 至 50 kHz","range":"22 mV to 220 mV","cmc":"1,4·10⁻⁵ · U + 9 µV"},{"name":"20 kHz 至 50 kHz","range":"0,22 V to 2,2 V","cmc":"7,6·10⁻⁵ · U + 13 µV"},{"name":"20 kHz 至 50 kHz","range":"2,2 V to 22 V","cmc":"7,8·10⁻⁵ · U + 0,12 mV"},{"name":"20 kHz 至 50 kHz","range":"22 V to 220 V","cmc":"9,2·10⁻⁵ · U + 1,2 mV"},{"name":"33 kHz 至 100 kHz","range":"220 V to 750 V","cmc":"6,0·10⁻⁴ · U + 0,23 V"},{"name":"50 kHz 至 100 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"50 kHz 至 100 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"50 kHz 至 100 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"50 kHz 至 100 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"50 kHz 至 100 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"50 kHz 至 100 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"100 kHz 至 300 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"100 kHz 至 300 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"100 kHz 至 300 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"100 kHz 至 300 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"100 kHz 至 300 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"100 kHz 至 300 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"300 kHz 至 1 MHz","range":"2,2 mV to 22 mV","cmc":"3,1·10⁻³ · U + 24 µV"},{"name":"300 kHz 至 1 MHz","range":"22 mV to 220 mV","cmc":"3,1·10⁻³ · U + 56 µV"},{"name":"300 kHz 至 1 MHz","range":"0,22 V to 2,2 V","cmc":"2,0·10⁻³ · U + 0,34 mV"},{"name":"300 kHz 至 1 MHz","range":"2,2 V to 22 V","cmc":"1,8·10⁻³ · U + 3,5 mV"}],"reference_zh":"LMEEiO/2 依据EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","regulatory_area_zh":"交流电压","search_zh":"万用表 数字电压表 模拟电压表 测量卡 手持示波表 电网参数测量仪 电气安全测试仪 分压器 测量探头 射频功率计 无线电通信测试仪 电子负载 线路参数与故障分析仪 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 20 Hz 至 40 Hz 40 Hz 至 50 Hz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 50 Hz 至 1 kHz 1 kHz 至 10 kHz 1 kHz 至 20 kHz 1 kHz 至 20 kHz 10 kHz 至 33 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 33 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 300 kHz 至 1 MHz 300 kHz 至 1 MHz 300 kHz 至 1 MHz 300 kHz 至 1 MHz LMEEiO/2 依据EURAMET cg-15 v. 3.0 LMEEiO/33 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"万用表\n数字电压表\n模拟电压表\n测量卡\n手持示波表\n电网参数测量仪\n电气安全测试仪\n分压器\n测量探头\n射频功率计\n无线电通信测试仪\n电子负载\n线路参数与故障分析仪","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"10 Hz až 40 Hz","range":"0,1 mV to 5 mV","cmc":"3,5·10⁻⁴ · U + 3,5 µV"},{"name":"10 Hz až 40 Hz","range":"5 mV to 12 mV","cmc":"1,5·10⁻⁴ · U + 4,7 µV"},{"name":"10 Hz až 40 Hz","range":"12 mV to 120 mV","cmc":"8·10⁻⁵ · U + 4,7 µ"},{"name":"10 Hz až 40 Hz","range":"0,12 V to 1,2 V","cmc":"8·10⁻⁵ · U + 47 µV"},{"name":"10 Hz až 40 Hz","range":"1,2 V to 12 V","cmc":"8·10⁻⁵ · U + 0,47 m"},{"name":"10 Hz až 40 Hz","range":"12 V to 20 V","cmc":"1,2·10⁻⁴ · U + 0,32 mV"},{"name":"10 Hz až 40 Hz","range":"20 V to 200V","cmc":"1,2·10⁻⁴ · U + 2,5 mV"},{"name":"10 Hz až 40 Hz","range":"200 V to 1000 V","cmc":"1,3·10⁻⁴ · U + 23 mV"},{"name":"20 Hz až 40 Hz","range":"0,22 V to 2,2 V","cmc":"8·10⁻⁵ · U + 22 µV"},{"name":"40 Hz až 50 Hz","range":"200 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"40 Hz až 1 kHz","range":"0,1 mV to 12 mV","cmc":"2,4·10⁻⁴ · U + 1,3 µV"},{"name":"40 Hz až 1 kHz","range":"12 mV to 120 mV","cmc":"8,2·10⁻⁵ · U + 2,3 µV"},{"name":"40 Hz až 20 kHz","range":"120 mV to 220 mV","cmc":"6,7·10⁻⁵ · U + 8,1 µV"},{"name":"40 Hz až 20 kHz","range":"0,22 V to 2,2 V","cmc":"4,2·10⁻⁵ · U + 12 µV"},{"name":"40 Hz až 20 kHz","range":"2,2 V to 22 V","cmc":"5,0·10⁻⁵ · U + 60 µV"},{"name":"40 Hz až 20 kHz","range":"22 V to 220 V","cmc":"6,0·10⁻⁵ · U + 0,8 mV"},{"name":"50 Hz až 1 kHz","range":"220 V to 1000 V","cmc":"8,0·10⁻⁵ · U + 4,5 mV"},{"name":"1 kHz až 10 kHz","range":"220 V to 1000 V","cmc":"1,1·10⁻⁴ · U + 23 mV"},{"name":"1 kHz až 20 kHz","range":"0,1 mV to 12 mV","cmc":"3,5·10⁻⁴ · U + 1,3 µV"},{"name":"1 kHz až 20 kHz","range":"12 mV to 120 mV","cmc":"1,2·10⁻⁴ · U + 4,6 µV"},{"name":"10 kHz až 33 kHz","range":"220 V to 1000 V","cmc":"1,9·10⁻⁴ · U + 21 mV"},{"name":"20 kHz až 50 kHz","range":"0,1 mV to 2,2 mV","cmc":"3,0·10⁻⁴ · U + 4,6 µV"},{"name":"20 kHz až 50 kHz","range":"2,2 mV to 22 mV","cmc":"2,3·10⁻⁴ · U + 4,7 µV"},{"name":"20 kHz až 50 kHz","range":"22 mV to 220 mV","cmc":"1,4·10⁻⁵ · U + 9 µV"},{"name":"20 kHz až 50 kHz","range":"0,22 V to 2,2 V","cmc":"7,6·10⁻⁵ · U + 13 µV"},{"name":"20 kHz až 50 kHz","range":"2,2 V to 22 V","cmc":"7,8·10⁻⁵ · U + 0,12 mV"},{"name":"20 kHz až 50 kHz","range":"22 V to 220 V","cmc":"9,2·10⁻⁵ · U + 1,2 mV"},{"name":"33 kHz až 100 kHz","range":"220 V to 750 V","cmc":"6,0·10⁻⁴ · U + 0,23 V"},{"name":"50 kHz až 100 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"50 kHz až 100 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"50 kHz až 100 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"50 kHz až 100 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"50 kHz až 100 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"50 kHz až 100 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"100 kHz až 300 kHz","range":"0,1 mV to 2,2 mV","cmc":"5,0·10⁻⁴ · U + 6 µV"},{"name":"100 kHz až 300 kHz","range":"2,2 mV to 22 mV","cmc":"6,0·10⁻⁴ · U + 5,7 µV"},{"name":"100 kHz až 300 kHz","range":"22 mV to 220 mV","cmc":"3,6·10⁻⁴ · U + 20 µV"},{"name":"100 kHz až 300 kHz","range":"0,22 V to 2,2 V","cmc":"1,0·10⁻⁴ · U + 34 µV"},{"name":"100 kHz až 300 kHz","range":"2,2 V to 22 V","cmc":"9,5·10⁻⁵ · U + 0,23 mV"},{"name":"100 kHz až 300 kHz","range":"22 V to 220 V","cmc":"1,8·10⁻⁴ · U + 2,7 mV"},{"name":"300 kHz až 1 MHz","range":"2,2 mV to 22 mV","cmc":"3,1·10⁻³ · U + 24 µV"},{"name":"300 kHz až 1 MHz","range":"22 mV to 220 mV","cmc":"3,1·10⁻³ · U + 56 µV"},{"name":"300 kHz až 1 MHz","range":"0,22 V to 2,2 V","cmc":"2,0·10⁻³ · U + 0,34 mV"},{"name":"300 kHz až 1 MHz","range":"2,2 V to 22 V","cmc":"1,8·10⁻³ · U + 3,5 mV"}],"reference_cs":"LMEEiO/2 na základě EURAMET cg-15 v. 3.0\nLMEEiO/33\nLMEEiO/35\nLMEEiO/42\nLMEEiO/45\nLMEEiO/53","regulatory_area_cs":"Napětí AC","search_cs":"Multimetry Digitální měřiče napětí Analogové měřiče napětí Měřicí karty Skopmetry Měřiče parametrů sítě Testery elektrické bezpečnosti Děliče napětí Měřicí sondy Měřiče VF výkonu Radiokomunikační testery Elektronické zátěže Analyzátory parametrů a poruch vedení Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 20 Hz až 40 Hz 40 Hz až 50 Hz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 50 Hz až 1 kHz 1 kHz až 10 kHz 1 kHz až 20 kHz 1 kHz až 20 kHz 10 kHz až 33 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 33 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 300 kHz až 1 MHz 300 kHz až 1 MHz 300 kHz až 1 MHz 300 kHz až 1 MHz LMEEiO/2 na základě EURAMET cg-15 v. 3.0 LMEEiO/33 LMEEiO/35 LMEEiO/42 LMEEiO/45 LMEEiO/53","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Multimetry\nDigitální měřiče napětí\nAnalogové měřiče napětí\nMěřicí karty\nSkopmetry\nMěřiče parametrů sítě\nTestery elektrické bezpečnosti\nDěliče napětí\nMěřicí sondy\nMěřiče VF výkonu\nRadiokomunikační testery\nElektronické zátěže\nAnalyzátory parametrů a poruch vedení"},{"_id":"abec58eac1c3458d50f0a9b1","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory jakości energii\n- współczynnik THD U","test_object_en":"Power quality analysers\n- THD U factor","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"50 Hz","range":"0% do 540 %","cmc":"0,1 %"}],"parameters_en":[{"name":"50 Hz","range":"0% to 540 %","cmc":"0,1 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\n50 Hz 0% do 540 % CMC 0,1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/50","norm_bases":["LMEEiO/50"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Analizatory jakości energii\n- współczynnik THD U Wzorcowanie — Napięcie AC\n50 Hz 0% do 540 % CMC 0,1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/50 Analizatory jakosci energii\n- wspolczynnik THD U Wzorcowanie — Napiecie AC\n50 Hz 0% do 540 % CMC 0,1 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/50","search_en":"Power quality analysers - THD U factor Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC voltage Internal procedure Direct method At permanent location (S) and outside of it (P) 50 Hz LMEEiO/50","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"50 Hz","range":"0% to 540 %","cmc":"0,1 %"}],"regulatory_area_de":"AC-Spannung","search_de":"Netzqualitätsanalysatoren - THD-U-Faktor Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 50 Hz LMEEiO/50","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Netzqualitätsanalysatoren\n- THD-U-Faktor","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"50 Hz","range":"0% to 540 %","cmc":"0,1 %"}],"regulatory_area_zh":"交流电压","search_zh":"电能质量分析仪 - 电压总谐波畸变率 THD U 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 50 Hz LMEEiO/50","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电能质量分析仪\n- 电压总谐波畸变率 THD U","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"50 Hz","range":"0% to 540 %","cmc":"0,1 %"}],"regulatory_area_cs":"Napětí AC","search_cs":"Analyzátory kvality elektrické energie - činitel THD U Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 Hz LMEEiO/50","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analyzátory kvality elektrické energie\n- činitel THD U"},{"_id":"438cd6255e208c600a50d1e0","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory jakości energii\n- wyższe harmoniczne napięcia","test_object_en":"Power quality analysers\n- voltage harmonics","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"50 Hz; do 31 harmonicznej","range":"0 V do 400 V","cmc":"0,1 %"}],"parameters_en":[{"name":"50 Hz; up to the 31st harmonic","range":"0 V to 400 V","cmc":"0,1 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\n50 Hz; do 31 harmonicznej 0 V do 400 V CMC 0,1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/50","norm_bases":["LMEEiO/50"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Analizatory jakości energii\n- wyższe harmoniczne napięcia Wzorcowanie — Napięcie AC\n50 Hz; do 31 harmonicznej 0 V do 400 V CMC 0,1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/50 Analizatory jakosci energii\n- wyzsze harmoniczne napiecia Wzorcowanie — Napiecie AC\n50 Hz; do 31 harmonicznej 0 V do 400 V CMC 0,1 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/50","search_en":"Power quality analysers - voltage harmonics Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC voltage Internal procedure Direct method At permanent location (S) and outside of it (P) 50 Hz; up to the 31st harmonic LMEEiO/50","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"50 Hz; bis zur 31. Harmonischen","range":"0 V to 400 V","cmc":"0,1 %"}],"regulatory_area_de":"AC-Spannung","search_de":"Netzqualitätsanalysatoren - Spannungsoberschwingungen Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 50 Hz; bis zur 31. Harmonischen LMEEiO/50","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Netzqualitätsanalysatoren\n- Spannungsoberschwingungen","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"50 Hz; 至 31 次谐波","range":"0 V to 400 V","cmc":"0,1 %"}],"regulatory_area_zh":"交流电压","search_zh":"电能质量分析仪 - 电压谐波 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 50 Hz; 至 31 次谐波 LMEEiO/50","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电能质量分析仪\n- 电压谐波","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"50 Hz; do 31. harmonické","range":"0 V to 400 V","cmc":"0,1 %"}],"regulatory_area_cs":"Napětí AC","search_cs":"Analyzátory kvality elektrické energie - vyšší harmonické napětí Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 Hz; do 31. harmonické LMEEiO/50","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analyzátory kvality elektrické energie\n- vyšší harmonické napětí"},{"_id":"f065cfa081305dfaceda690a","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki napięcia analogowe\nMierniki napięcia cyfrowe\n- wejście asymetryczne: od 1 mV do 100 V (50; 75; 100; 135; 150; 600) Ω; wysokoomowe\n- wejście symetryczne: od 1 mV do 10 V (100; 124; 135; 150; 600) Ω; wysokoomowe","test_object_en":"Analogue voltmeters\nDigital voltmeters\n- unbalanced input: from 1 mV to 100 V (50; 75; 100; 135; 150; 600) Ω; high impedance\n- balanced input: from 1 mV to 10 V (100; 124; 135; 150; 600) Ω; high impedance","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"20 Hz do 30 Hz","range":"1 mV","cmc":"0,72%"},{"name":"20 Hz do 30 Hz","range":"1 mV do 10 mV","cmc":"0,10%"},{"name":"20 Hz do 30 Hz","range":"10 mV do 100 mV","cmc":"0,04%"},{"name":"20 Hz do 30 Hz","range":"0,1 V do 10 V","cmc":"0,02%"},{"name":"20 Hz do 30 Hz","range":"10 V do 100 V","cmc":"0,03%"},{"name":"30 Hz do 30 kHz","range":"1 mV","cmc":"0,72%"},{"name":"30 Hz do 30 kHz","range":"1 mV do 10 mV","cmc":"0,10%"},{"name":"30 Hz do 30 kHz","range":"10 mV do 100 mV","cmc":"0,07%"},{"name":"30 Hz do 30 kHz","range":"0,1 V do 10 V","cmc":"0,02%"},{"name":"30 Hz do 30 kHz","range":"10 V do 100 V","cmc":"0,03%"},{"name":"30 kHz do 100 kHz","range":"1 mV","cmc":"0,81%"},{"name":"30 kHz do 100 kHz","range":"1 mV do 10 mV","cmc":"0,18%"},{"name":"30 kHz do 100 kHz","range":"10 mV do 100 mV","cmc":"0,15%"},{"name":"30 kHz do 100 kHz","range":"0,1 V do 100 V","cmc":"0,04%"}],"parameters_en":[{"name":"20 Hz to 30 Hz","range":"1 mV","cmc":"0,72%"},{"name":"20 Hz to 30 Hz","range":"1 mV to 10 mV","cmc":"0,10%"},{"name":"20 Hz to 30 Hz","range":"10 mV to 100 mV","cmc":"0,04%"},{"name":"20 Hz to 30 Hz","range":"0,1 V to 10 V","cmc":"0,02%"},{"name":"20 Hz to 30 Hz","range":"10 V to 100 V","cmc":"0,03%"},{"name":"30 Hz to 30 kHz","range":"1 mV","cmc":"0,72%"},{"name":"30 Hz to 30 kHz","range":"1 mV to 10 mV","cmc":"0,10%"},{"name":"30 Hz to 30 kHz","range":"10 mV to 100 mV","cmc":"0,07%"},{"name":"30 Hz to 30 kHz","range":"0,1 V to 10 V","cmc":"0,02%"},{"name":"30 Hz to 30 kHz","range":"10 V to 100 V","cmc":"0,03%"},{"name":"30 kHz to 100 kHz","range":"1 mV","cmc":"0,81%"},{"name":"30 kHz to 100 kHz","range":"1 mV to 10 mV","cmc":"0,18%"},{"name":"30 kHz to 100 kHz","range":"10 mV to 100 mV","cmc":"0,15%"},{"name":"30 kHz to 100 kHz","range":"0,1 V to 100 V","cmc":"0,04%"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n20 Hz do 30 Hz 1 mV CMC 0,72%\n20 Hz do 30 Hz 1 mV do 10 mV CMC 0,10%\n20 Hz do 30 Hz 10 mV do 100 mV CMC 0,04%\n20 Hz do 30 Hz 0,1 V do 10 V CMC 0,02%\n20 Hz do 30 Hz 10 V do 100 V CMC 0,03%\n30 Hz do 30 kHz 1 mV CMC 0,72%\n30 Hz do 30 kHz 1 mV do 10 mV CMC 0,10%\n30 Hz do 30 kHz 10 mV do 100 mV CMC 0,07%\n30 Hz do 30 kHz 0,1 V do 10 V CMC 0,02%\n30 Hz do 30 kHz 10 V do 100 V CMC 0,03%\n30 kHz do 100 kHz 1 mV CMC 0,81%\n30 kHz do 100 kHz 1 mV do 10 mV CMC 0,18%\n30 kHz do 100 kHz 10 mV do 100 mV CMC 0,15%\n30 kHz do 100 kHz 0,1 V do 100 V CMC 0,04%\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/11","norm_bases":["LMEEiO/11"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki napięcia analogowe\nMierniki napięcia cyfrowe\n- wejście asymetryczne: od 1 mV do 100 V (50; 75; 100; 135; 150; 600) Ω; wysokoomowe\n- wejście symetryczne: od 1 mV do 10 V (100; 124; 135; 150; 600) Ω; wysokoomowe Wzorcowanie — Napięcie AC\nZakres:\n20 Hz do 30 Hz 1 mV CMC 0,72%\n20 Hz do 30 Hz 1 mV do 10 mV CMC 0,10%\n20 Hz do 30 Hz 10 mV do 100 mV CMC 0,04%\n20 Hz do 30 Hz 0,1 V do 10 V CMC 0,02%\n20 Hz do 30 Hz 10 V do 100 V CMC 0,03%\n30 Hz do 30 kHz 1 mV CMC 0,72%\n30 Hz do 30 kHz 1 mV do 10 mV CMC 0,10%\n30 Hz do 30 kHz 10 mV do 100 mV CMC 0,07%\n30 Hz do 30 kHz 0,1 V do 10 V CMC 0,02%\n30 Hz do 30 kHz 10 V do 100 V CMC 0,03%\n30 kHz do 100 kHz 1 mV CMC 0,81%\n30 kHz do 100 kHz 1 mV do 10 mV CMC 0,18%\n30 kHz do 100 kHz 10 mV do 100 mV CMC 0,15%\n30 kHz do 100 kHz 0,1 V do 100 V CMC 0,04%\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/11 Mierniki napiecia analogowe\nMierniki napiecia cyfrowe\n- wejscie asymetryczne: od 1 mV do 100 V (50; 75; 100; 135; 150; 600) Ω; wysokoomowe\n- wejscie symetryczne: od 1 mV do 10 V (100; 124; 135; 150; 600) Ω; wysokoomowe Wzorcowanie — Napiecie AC\nZakres:\n20 Hz do 30 Hz 1 mV CMC 0,72%\n20 Hz do 30 Hz 1 mV do 10 mV CMC 0,10%\n20 Hz do 30 Hz 10 mV do 100 mV CMC 0,04%\n20 Hz do 30 Hz 0,1 V do 10 V CMC 0,02%\n20 Hz do 30 Hz 10 V do 100 V CMC 0,03%\n30 Hz do 30 kHz 1 mV CMC 0,72%\n30 Hz do 30 kHz 1 mV do 10 mV CMC 0,10%\n30 Hz do 30 kHz 10 mV do 100 mV CMC 0,07%\n30 Hz do 30 kHz 0,1 V do 10 V CMC 0,02%\n30 Hz do 30 kHz 10 V do 100 V CMC 0,03%\n30 kHz do 100 kHz 1 mV CMC 0,81%\n30 kHz do 100 kHz 1 mV do 10 mV CMC 0,18%\n30 kHz do 100 kHz 10 mV do 100 mV CMC 0,15%\n30 kHz do 100 kHz 0,1 V do 100 V CMC 0,04%\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/11","search_en":"Analogue voltmeters Digital voltmeters - unbalanced input: from 1 mV to 100 V (50; 75; 100; 135; 150; 600) Ω; high impedance - balanced input: from 1 mV to 10 V (100; 124; 135; 150; 600) Ω; high impedance Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC voltage Internal procedure Direct method At permanent location (S) and outside of it (P) 20 Hz to 30 Hz 20 Hz to 30 Hz 20 Hz to 30 Hz 20 Hz to 30 Hz 20 Hz to 30 Hz 30 Hz to 30 kHz 30 Hz to 30 kHz 30 Hz to 30 kHz 30 Hz to 30 kHz 30 Hz to 30 kHz 30 kHz to 100 kHz 30 kHz to 100 kHz 30 kHz to 100 kHz 30 kHz to 100 kHz LMEEiO/11","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"20 Hz bis 30 Hz","range":"1 mV","cmc":"0,72%"},{"name":"20 Hz bis 30 Hz","range":"1 mV to 10 mV","cmc":"0,10%"},{"name":"20 Hz bis 30 Hz","range":"10 mV to 100 mV","cmc":"0,04%"},{"name":"20 Hz bis 30 Hz","range":"0,1 V bis 10 V","cmc":"0,02%"},{"name":"20 Hz bis 30 Hz","range":"10 V to 100 V","cmc":"0,03%"},{"name":"30 Hz bis 30 kHz","range":"1 mV","cmc":"0,72%"},{"name":"30 Hz bis 30 kHz","range":"1 mV to 10 mV","cmc":"0,10%"},{"name":"30 Hz bis 30 kHz","range":"10 mV to 100 mV","cmc":"0,07%"},{"name":"30 Hz bis 30 kHz","range":"0,1 V bis 10 V","cmc":"0,02%"},{"name":"30 Hz bis 30 kHz","range":"10 V to 100 V","cmc":"0,03%"},{"name":"30 kHz bis 100 kHz","range":"1 mV","cmc":"0,81%"},{"name":"30 kHz bis 100 kHz","range":"1 mV to 10 mV","cmc":"0,18%"},{"name":"30 kHz bis 100 kHz","range":"10 mV to 100 mV","cmc":"0,15%"},{"name":"30 kHz bis 100 kHz","range":"0,1 V to 100 V","cmc":"0,04%"}],"regulatory_area_de":"AC-Spannung","search_de":"Analoge Spannungsmessgeräte Digitale Spannungsmessgeräte - unsymmetrischer Eingang: von 1 mV bis 100 V (50; 75; 100; 135; 150; 600) Ω; hochohmig - symmetrischer Eingang: von 1 mV bis 10 V (100; 124; 135; 150; 600) Ω; hochohmig Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 20 Hz bis 30 Hz 20 Hz bis 30 Hz 20 Hz bis 30 Hz 20 Hz bis 30 Hz 20 Hz bis 30 Hz 30 Hz bis 30 kHz 30 Hz bis 30 kHz 30 Hz bis 30 kHz 30 Hz bis 30 kHz 30 Hz bis 30 kHz 30 kHz bis 100 kHz 30 kHz bis 100 kHz 30 kHz bis 100 kHz 30 kHz bis 100 kHz LMEEiO/11","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Analoge Spannungsmessgeräte\nDigitale Spannungsmessgeräte\n- unsymmetrischer Eingang: von 1 mV bis 100 V (50; 75; 100; 135; 150; 600) Ω; hochohmig\n- symmetrischer Eingang: von 1 mV bis 10 V (100; 124; 135; 150; 600) Ω; hochohmig","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"20 Hz 至 30 Hz","range":"1 mV","cmc":"0,72%"},{"name":"20 Hz 至 30 Hz","range":"1 mV to 10 mV","cmc":"0,10%"},{"name":"20 Hz 至 30 Hz","range":"10 mV to 100 mV","cmc":"0,04%"},{"name":"20 Hz 至 30 Hz","range":"0,1 V to 10 V","cmc":"0,02%"},{"name":"20 Hz 至 30 Hz","range":"10 V to 100 V","cmc":"0,03%"},{"name":"30 Hz 至 30 kHz","range":"1 mV","cmc":"0,72%"},{"name":"30 Hz 至 30 kHz","range":"1 mV to 10 mV","cmc":"0,10%"},{"name":"30 Hz 至 30 kHz","range":"10 mV to 100 mV","cmc":"0,07%"},{"name":"30 Hz 至 30 kHz","range":"0,1 V to 10 V","cmc":"0,02%"},{"name":"30 Hz 至 30 kHz","range":"10 V to 100 V","cmc":"0,03%"},{"name":"30 kHz 至 100 kHz","range":"1 mV","cmc":"0,81%"},{"name":"30 kHz 至 100 kHz","range":"1 mV to 10 mV","cmc":"0,18%"},{"name":"30 kHz 至 100 kHz","range":"10 mV to 100 mV","cmc":"0,15%"},{"name":"30 kHz 至 100 kHz","range":"0,1 V to 100 V","cmc":"0,04%"}],"regulatory_area_zh":"交流电压","search_zh":"模拟电压表 数字电压表 - 不平衡输入：1 mV 至 100 V（50；75；100；135；150；600）Ω；高阻 - 平衡输入：1 mV 至 10 V（100；124；135；150；600）Ω；高阻 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 20 Hz 至 30 Hz 20 Hz 至 30 Hz 20 Hz 至 30 Hz 20 Hz 至 30 Hz 20 Hz 至 30 Hz 30 Hz 至 30 kHz 30 Hz 至 30 kHz 30 Hz 至 30 kHz 30 Hz 至 30 kHz 30 Hz 至 30 kHz 30 kHz 至 100 kHz 30 kHz 至 100 kHz 30 kHz 至 100 kHz 30 kHz 至 100 kHz LMEEiO/11","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"模拟电压表\n数字电压表\n- 不平衡输入：1 mV 至 100 V（50；75；100；135；150；600）Ω；高阻\n- 平衡输入：1 mV 至 10 V（100；124；135；150；600）Ω；高阻","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"20 Hz až 30 Hz","range":"1 mV","cmc":"0,72%"},{"name":"20 Hz až 30 Hz","range":"1 mV to 10 mV","cmc":"0,10%"},{"name":"20 Hz až 30 Hz","range":"10 mV to 100 mV","cmc":"0,04%"},{"name":"20 Hz až 30 Hz","range":"0,1 V to 10 V","cmc":"0,02%"},{"name":"20 Hz až 30 Hz","range":"10 V to 100 V","cmc":"0,03%"},{"name":"30 Hz až 30 kHz","range":"1 mV","cmc":"0,72%"},{"name":"30 Hz až 30 kHz","range":"1 mV to 10 mV","cmc":"0,10%"},{"name":"30 Hz až 30 kHz","range":"10 mV to 100 mV","cmc":"0,07%"},{"name":"30 Hz až 30 kHz","range":"0,1 V to 10 V","cmc":"0,02%"},{"name":"30 Hz až 30 kHz","range":"10 V to 100 V","cmc":"0,03%"},{"name":"30 kHz až 100 kHz","range":"1 mV","cmc":"0,81%"},{"name":"30 kHz až 100 kHz","range":"1 mV to 10 mV","cmc":"0,18%"},{"name":"30 kHz až 100 kHz","range":"10 mV to 100 mV","cmc":"0,15%"},{"name":"30 kHz až 100 kHz","range":"0,1 V to 100 V","cmc":"0,04%"}],"regulatory_area_cs":"Napětí AC","search_cs":"Analogové měřiče napětí Digitální měřiče napětí - nesymetrický vstup: od 1 mV do 100 V (50; 75; 100; 135; 150; 600) Ω; vysokoimpedanční - symetrický vstup: od 1 mV do 10 V (100; 124; 135; 150; 600) Ω; vysokoimpedanční Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 20 Hz až 30 Hz 20 Hz až 30 Hz 20 Hz až 30 Hz 20 Hz až 30 Hz 20 Hz až 30 Hz 30 Hz až 30 kHz 30 Hz až 30 kHz 30 Hz až 30 kHz 30 Hz až 30 kHz 30 Hz až 30 kHz 30 kHz až 100 kHz 30 kHz až 100 kHz 30 kHz až 100 kHz 30 kHz až 100 kHz LMEEiO/11","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analogové měřiče napětí\nDigitální měřiče napětí\n- nesymetrický vstup: od 1 mV do 100 V (50; 75; 100; 135; 150; 600) Ω; vysokoimpedanční\n- symetrický vstup: od 1 mV do 10 V (100; 124; 135; 150; 600) Ω; vysokoimpedanční"},{"_id":"408ae4c4a80ebe244bbd84dc","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Oscyloskopy\nKarty pomiarowe\nSkopometry\n- nierówność charakterystyki częstotliwościowej odniesiona do wskazania w paśmie 50 kHz do 10 MHz","test_object_en":"Oscilloscopes\nData acquisition cards\nScopemeters\n- frequency response flatness relative to the indication in the 50 kHz to 10 MHz band","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"50 kHz do 10 MHz","range":"4,44 mV do 5,56 V","cmc":"1,8%"},{"name":"100 mHz do 100 MHz","range":"4,44 mV do 5,56 V","cmc":"1,8%"},{"name":"100 MHz do 300 MHz","range":"4,44 mV do 5,56 V","cmc":"2,4%"},{"name":"300 MHz do 550 MHz","range":"4,44 mV do 5,56 V","cmc":"2,9%"},{"name":"550 MHz do 3 GHz","range":"4,44 mV do 2,224 V","cmc":"4,1%"},{"name":"3 GHz do 6 GHz","range":"22,24 mV do 2,224 V","cmc":"5,8%"},{"name":"6 GHz do 10 GHz","range":"22,24 mV do 2,224 V","cmc":"5,5%"},{"name":"10 GHz do 12,4 GHz","range":"22,24 mV do 2,224 V","cmc":"6,3%"},{"name":"12,4 GHz do 20 GHz","range":"22,24 mV do 2,224 V","cmc":"8,6%"}],"parameters_en":[{"name":"50 kHz to 10 MHz","range":"4,44 mV to 5,56 V","cmc":"1,8%"},{"name":"100 mHz to 100 MHz","range":"4,44 mV to 5,56 V","cmc":"1,8%"},{"name":"100 MHz to 300 MHz","range":"4,44 mV to 5,56 V","cmc":"2,4%"},{"name":"300 MHz to 550 MHz","range":"4,44 mV to 5,56 V","cmc":"2,9%"},{"name":"550 MHz to 3 GHz","range":"4,44 mV to 2,224 V","cmc":"4,1%"},{"name":"3 GHz to 6 GHz","range":"22,24 mV to 2,224 V","cmc":"5,8%"},{"name":"6 GHz to 10 GHz","range":"22,24 mV to 2,224 V","cmc":"5,5%"},{"name":"10 GHz to 12,4 GHz","range":"22,24 mV to 2,224 V","cmc":"6,3%"},{"name":"12,4 GHz to 20 GHz","range":"22,24 mV to 2,224 V","cmc":"8,6%"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n50 kHz do 10 MHz 4,44 mV do 5,56 V CMC 1,8%\n100 mHz do 100 MHz 4,44 mV do 5,56 V CMC 1,8%\n100 MHz do 300 MHz 4,44 mV do 5,56 V CMC 2,4%\n300 MHz do 550 MHz 4,44 mV do 5,56 V CMC 2,9%\n550 MHz do 3 GHz 4,44 mV do 2,224 V CMC 4,1%\n3 GHz do 6 GHz 22,24 mV do 2,224 V CMC 5,8%\n6 GHz do 10 GHz 22,24 mV do 2,224 V CMC 5,5%\n10 GHz do 12,4 GHz 22,24 mV do 2,224 V CMC 6,3%\n12,4 GHz do 20 GHz 22,24 mV do 2,224 V CMC 8,6%\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/13 w oparciu o EURAMET cg-7 v. 1.0","norm_bases":["LMEEiO/13","EURAMET cg-7 v. 1.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Oscyloskopy\nKarty pomiarowe\nSkopometry\n- nierówność charakterystyki częstotliwościowej odniesiona do wskazania w paśmie 50 kHz do 10 MHz Wzorcowanie — Napięcie AC\nZakres:\n50 kHz do 10 MHz 4,44 mV do 5,56 V CMC 1,8%\n100 mHz do 100 MHz 4,44 mV do 5,56 V CMC 1,8%\n100 MHz do 300 MHz 4,44 mV do 5,56 V CMC 2,4%\n300 MHz do 550 MHz 4,44 mV do 5,56 V CMC 2,9%\n550 MHz do 3 GHz 4,44 mV do 2,224 V CMC 4,1%\n3 GHz do 6 GHz 22,24 mV do 2,224 V CMC 5,8%\n6 GHz do 10 GHz 22,24 mV do 2,224 V CMC 5,5%\n10 GHz do 12,4 GHz 22,24 mV do 2,224 V CMC 6,3%\n12,4 GHz do 20 GHz 22,24 mV do 2,224 V CMC 8,6%\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/13 w oparciu o EURAMET cg-7 v. 1.0 Oscyloskopy\nKarty pomiarowe\nSkopometry\n- nierownosc charakterystyki czestotliwosciowej odniesiona do wskazania w pasmie 50 kHz do 10 MHz Wzorcowanie — Napiecie AC\nZakres:\n50 kHz do 10 MHz 4,44 mV do 5,56 V CMC 1,8%\n100 mHz do 100 MHz 4,44 mV do 5,56 V CMC 1,8%\n100 MHz do 300 MHz 4,44 mV do 5,56 V CMC 2,4%\n300 MHz do 550 MHz 4,44 mV do 5,56 V CMC 2,9%\n550 MHz do 3 GHz 4,44 mV do 2,224 V CMC 4,1%\n3 GHz do 6 GHz 22,24 mV do 2,224 V CMC 5,8%\n6 GHz do 10 GHz 22,24 mV do 2,224 V CMC 5,5%\n10 GHz do 12,4 GHz 22,24 mV do 2,224 V CMC 6,3%\n12,4 GHz do 20 GHz 22,24 mV do 2,224 V CMC 8,6%\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/13 w oparciu o EURAMET cg-7 v. 1.0","search_en":"Oscilloscopes Data acquisition cards Scopemeters - frequency response flatness relative to the indication in the 50 kHz to 10 MHz band Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC voltage Internal procedure Direct method At permanent location (S) and outside of it (P) 50 kHz to 10 MHz 100 mHz to 100 MHz 100 MHz to 300 MHz 300 MHz to 550 MHz 550 MHz to 3 GHz 3 GHz to 6 GHz 6 GHz to 10 GHz 10 GHz to 12,4 GHz 12,4 GHz to 20 GHz LMEEiO/13 based on EURAMET cg-7 v. 1.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/13 based on EURAMET cg-7 v. 1.0","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"50 kHz bis 10 MHz","range":"4,44 mV to 5,56 V","cmc":"1,8%"},{"name":"100 mHz bis 100 MHz","range":"4,44 mV to 5,56 V","cmc":"1,8%"},{"name":"100 MHz bis 300 MHz","range":"4,44 mV to 5,56 V","cmc":"2,4%"},{"name":"300 MHz bis 550 MHz","range":"4,44 mV to 5,56 V","cmc":"2,9%"},{"name":"550 MHz bis 3 GHz","range":"4,44 mV to 2,224 V","cmc":"4,1%"},{"name":"3 GHz bis 6 GHz","range":"22,24 mV to 2,224 V","cmc":"5,8%"},{"name":"6 GHz bis 10 GHz","range":"22,24 mV to 2,224 V","cmc":"5,5%"},{"name":"10 GHz bis 12,4 GHz","range":"22,24 mV to 2,224 V","cmc":"6,3%"},{"name":"12,4 GHz bis 20 GHz","range":"22,24 mV to 2,224 V","cmc":"8,6%"}],"reference_de":"LMEEiO/13 auf Grundlage von EURAMET cg-7 v. 1.0","regulatory_area_de":"AC-Spannung","search_de":"Oszilloskope Messkarten Scopemeter - Welligkeit des Frequenzgangs bezogen auf die Anzeige im Band 50 kHz bis 10 MHz Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 50 kHz bis 10 MHz 100 mHz bis 100 MHz 100 MHz bis 300 MHz 300 MHz bis 550 MHz 550 MHz bis 3 GHz 3 GHz bis 6 GHz 6 GHz bis 10 GHz 10 GHz bis 12,4 GHz 12,4 GHz bis 20 GHz LMEEiO/13 auf Grundlage von EURAMET cg-7 v. 1.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Oszilloskope\nMesskarten\nScopemeter\n- Welligkeit des Frequenzgangs bezogen auf die Anzeige im Band 50 kHz bis 10 MHz","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"50 kHz 至 10 MHz","range":"4,44 mV to 5,56 V","cmc":"1,8%"},{"name":"100 mHz 至 100 MHz","range":"4,44 mV to 5,56 V","cmc":"1,8%"},{"name":"100 MHz 至 300 MHz","range":"4,44 mV to 5,56 V","cmc":"2,4%"},{"name":"300 MHz 至 550 MHz","range":"4,44 mV to 5,56 V","cmc":"2,9%"},{"name":"550 MHz 至 3 GHz","range":"4,44 mV to 2,224 V","cmc":"4,1%"},{"name":"3 GHz 至 6 GHz","range":"22,24 mV to 2,224 V","cmc":"5,8%"},{"name":"6 GHz 至 10 GHz","range":"22,24 mV to 2,224 V","cmc":"5,5%"},{"name":"10 GHz 至 12,4 GHz","range":"22,24 mV to 2,224 V","cmc":"6,3%"},{"name":"12,4 GHz 至 20 GHz","range":"22,24 mV to 2,224 V","cmc":"8,6%"}],"reference_zh":"LMEEiO/13 依据EURAMET cg-7 v. 1.0","regulatory_area_zh":"交流电压","search_zh":"示波器 测量卡 手持示波表 - 频率响应平坦度（相对于 50 kHz 至 10 MHz 频带内的示值） 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 50 kHz 至 10 MHz 100 mHz 至 100 MHz 100 MHz 至 300 MHz 300 MHz 至 550 MHz 550 MHz 至 3 GHz 3 GHz 至 6 GHz 6 GHz 至 10 GHz 10 GHz 至 12,4 GHz 12,4 GHz 至 20 GHz LMEEiO/13 依据EURAMET cg-7 v. 1.0","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"示波器\n测量卡\n手持示波表\n- 频率响应平坦度（相对于 50 kHz 至 10 MHz 频带内的示值）","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"50 kHz až 10 MHz","range":"4,44 mV to 5,56 V","cmc":"1,8%"},{"name":"100 mHz až 100 MHz","range":"4,44 mV to 5,56 V","cmc":"1,8%"},{"name":"100 MHz až 300 MHz","range":"4,44 mV to 5,56 V","cmc":"2,4%"},{"name":"300 MHz až 550 MHz","range":"4,44 mV to 5,56 V","cmc":"2,9%"},{"name":"550 MHz až 3 GHz","range":"4,44 mV to 2,224 V","cmc":"4,1%"},{"name":"3 GHz až 6 GHz","range":"22,24 mV to 2,224 V","cmc":"5,8%"},{"name":"6 GHz až 10 GHz","range":"22,24 mV to 2,224 V","cmc":"5,5%"},{"name":"10 GHz až 12,4 GHz","range":"22,24 mV to 2,224 V","cmc":"6,3%"},{"name":"12,4 GHz až 20 GHz","range":"22,24 mV to 2,224 V","cmc":"8,6%"}],"reference_cs":"LMEEiO/13 na základě EURAMET cg-7 v. 1.0","regulatory_area_cs":"Napětí AC","search_cs":"Osciloskopy Měřicí karty Skopmetry - nerovnoměrnost kmitočtové charakteristiky vztažená k údaji v pásmu 50 kHz až 10 MHz Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 kHz až 10 MHz 100 mHz až 100 MHz 100 MHz až 300 MHz 300 MHz až 550 MHz 550 MHz až 3 GHz 3 GHz až 6 GHz 6 GHz až 10 GHz 10 GHz až 12,4 GHz 12,4 GHz až 20 GHz LMEEiO/13 na základě EURAMET cg-7 v. 1.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Osciloskopy\nMěřicí karty\nSkopmetry\n- nerovnoměrnost kmitočtové charakteristiky vztažená k údaji v pásmu 50 kHz až 10 MHz"},{"_id":"bef5367c3e37876d450a9e61","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Kalibratory\nKarty pomiarowe\nSymulatory prądu upływu\nZasilacze\nMostki\nTestery bezpieczeństwa elektrycznego\nMierniki parametrów sieci","test_object_en":"Calibrators\nData acquisition cards\nLeakage current simulators\nPower supplies\nBridges\nElectrical safety testers\nPower network parameter meters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"10 Hz do 40 Hz","range":"10 µA do 200 µA","cmc":"2,0·10⁻⁴ · I + 15 nA"},{"name":"10 Hz do 40 Hz","range":"0,2 mA do 2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"10 Hz do 40 Hz","range":"2 mA do 20 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"10 Hz do 40 Hz","range":"20 mA do 200 mA","cmc":"2,0·10⁻⁴ · I + 10 µA"},{"name":"10 Hz do 45 Hz","range":"0,2 A do 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,14 mA"},{"name":"10 Hz do 45 Hz","range":"1,2 A do 3,1 A","cmc":"2,5·10⁻⁴ · I + 0,9 mA"},{"name":"10 Hz do 45 Hz","range":"3,1 A do 12 A","cmc":"3,5·10⁻⁴ · I + 1,1 mA"},{"name":"10 Hz do 45 Hz","range":"12 A do 30 A","cmc":"6,0·10⁻⁴ · I + 20 mA"},{"name":"40 Hz do 1 kHz","range":"10 µA do 220 µA","cmc":"1,2·10⁻⁴ · I + 10 nA"},{"name":"40 Hz do 1 kHz","range":"0,22 mA do 2,2 mA","cmc":"1,2·10⁻⁴ · I + 40 nA"},{"name":"40 Hz do 1 kHz","range":"2,2 mA do 22 mA","cmc":"1,2·10⁻⁴ · I + 0,4 µA"},{"name":"40 Hz do 1 kHz","range":"22 mA do 220 mA","cmc":"1,2·10⁻⁴ · I + 3 µA"},{"name":"45 Hz do 1 kHz","range":"0,22 A do 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,07 mA"},{"name":"45 Hz do 1 kHz","range":"1,2 A do 3,1 A","cmc":"2,0·10⁻⁴ · I + 0,5 mA"},{"name":"45 Hz do 1 kHz","range":"3,1 A do 12 A","cmc":"3,0·10⁻⁴ · I + 0,8 mA"},{"name":"45 Hz do 1 kHz","range":"12 A do 30 A","cmc":"4,0·10⁻⁴ · I + 15 mA"},{"name":"1 kHz do 5 kHz","range":"10 µA do 120 µA","cmc":"2,0·10⁻⁴ · I + 13 nA"},{"name":"1 kHz do 5 kHz","range":"0,12 mA do 1,2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"1 kHz do 5 kHz","range":"1,2 mA do 12 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"1 kHz do 5 kHz","range":"12 mA do 120 mA","cmc":"2,2·10⁻⁴ · I + 9 µA"},{"name":"1 kHz do 5 kHz","range":"0,12 A do 1,2 A","cmc":"2,2·10⁻⁴ · I + 0,1 mA"},{"name":"1 kHz do 5 kHz","range":"1,2 A do 3,1 A","cmc":"2,2·10⁻⁴ · I + 0,7 mA"},{"name":"1 kHz do 5 kHz","range":"3,1 A do 12 A","cmc":"3,3·10⁻⁴ · I + 1 mA"},{"name":"1 kHz do 5 kHz","range":"12 A do 30 A","cmc":"4,0·10⁻³ · I + 20 mA"},{"name":"5 kHz do 10 kHz","range":"10 µA do 200 µA","cmc":"5,4·10⁻⁴ · I + 25 nA"},{"name":"5 kHz do 10 kHz","range":"0,2 mA do 2 mA","cmc":"3,2·10⁻⁴ · I + 0,25 µA"},{"name":"5 kHz do 10 kHz","range":"2 mA do 20 mA","cmc":"3,2·10⁻⁴ · I + 2,5 µA"},{"name":"5 kHz do 10 kHz","range":"20 mA do 200 mA","cmc":"3,0·10⁻⁴ · I + 22 µA"},{"name":"5 kHz do 10 kHz","range":"0,2 A do 2 A","cmc":"8,0·10⁻⁴ · I + 0,25 mA"},{"name":"5 kHz do 10 kHz","range":"2 A do 3,1 A","cmc":"2,2·10⁻³ · I + 0,7 mA"},{"name":"5 kHz do 10 kHz","range":"3,1 A do 12 A","cmc":"2,2·10⁻³ · I + 1,2 mA"},{"name":"10 kHz do 20 kHz","range":"10 µA do 200 µA","cmc":"7,5·10⁻⁴ · I + 25 nA"},{"name":"10 kHz do 20 kHz","range":"0,2 mA do 2 mA","cmc":"7,5·10⁻⁴ · I + 0,25 µA"},{"name":"10 kHz do 20 kHz","range":"2 mA do 20 mA","cmc":"7,5·10⁻⁴ · I + 2,5 µA"},{"name":"10 kHz do 20 kHz","range":"20 mA do 200 mA","cmc":"7,0·10⁻⁴ · I + 23 µA"},{"name":"10 kHz do 20 kHz","range":"0,2 A do 2 A","cmc":"3,3·10⁻³ · I + 0,6 mA"},{"name":"45 Hz do 400 Hz","range":"10 A do 100 A","cmc":"0,065 %"},{"name":"45 Hz do 400 Hz","range":"100 A do 1000 A","cmc":"0,2 %"},{"name":"400 Hz do 1 kHz","range":"10 A do 100 A","cmc":"0,08 %"},{"name":"50 Hz do 60 Hz","range":"100 A do 500 A","cmc":"0,05 %"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"10 µA to 200 µA","cmc":"2,0·10⁻⁴ · I + 15 nA"},{"name":"10 Hz to 40 Hz","range":"0,2 mA to 2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"10 Hz to 40 Hz","range":"2 mA to 20 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"10 Hz to 40 Hz","range":"20 mA to 200 mA","cmc":"2,0·10⁻⁴ · I + 10 µA"},{"name":"10 Hz to 45 Hz","range":"0,2 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,14 mA"},{"name":"10 Hz to 45 Hz","range":"1,2 A to 3,1 A","cmc":"2,5·10⁻⁴ · I + 0,9 mA"},{"name":"10 Hz to 45 Hz","range":"3,1 A to 12 A","cmc":"3,5·10⁻⁴ · I + 1,1 mA"},{"name":"10 Hz to 45 Hz","range":"12 A to 30 A","cmc":"6,0·10⁻⁴ · I + 20 mA"},{"name":"40 Hz to 1 kHz","range":"10 µA to 220 µA","cmc":"1,2·10⁻⁴ · I + 10 nA"},{"name":"40 Hz to 1 kHz","range":"0,22 mA to 2,2 mA","cmc":"1,2·10⁻⁴ · I + 40 nA"},{"name":"40 Hz to 1 kHz","range":"2,2 mA to 22 mA","cmc":"1,2·10⁻⁴ · I + 0,4 µA"},{"name":"40 Hz to 1 kHz","range":"22 mA to 220 mA","cmc":"1,2·10⁻⁴ · I + 3 µA"},{"name":"45 Hz to 1 kHz","range":"0,22 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,07 mA"},{"name":"45 Hz to 1 kHz","range":"1,2 A to 3,1 A","cmc":"2,0·10⁻⁴ · I + 0,5 mA"},{"name":"45 Hz to 1 kHz","range":"3,1 A to 12 A","cmc":"3,0·10⁻⁴ · I + 0,8 mA"},{"name":"45 Hz to 1 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻⁴ · I + 15 mA"},{"name":"1 kHz to 5 kHz","range":"10 µA to 120 µA","cmc":"2,0·10⁻⁴ · I + 13 nA"},{"name":"1 kHz to 5 kHz","range":"0,12 mA to 1,2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"1 kHz to 5 kHz","range":"1,2 mA to 12 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"1 kHz to 5 kHz","range":"12 mA to 120 mA","cmc":"2,2·10⁻⁴ · I + 9 µA"},{"name":"1 kHz to 5 kHz","range":"0,12 A to 1,2 A","cmc":"2,2·10⁻⁴ · I + 0,1 mA"},{"name":"1 kHz to 5 kHz","range":"1,2 A to 3,1 A","cmc":"2,2·10⁻⁴ · I + 0,7 mA"},{"name":"1 kHz to 5 kHz","range":"3,1 A to 12 A","cmc":"3,3·10⁻⁴ · I + 1 mA"},{"name":"1 kHz to 5 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻³ · I + 20 mA"},{"name":"5 kHz to 10 kHz","range":"10 µA to 200 µA","cmc":"5,4·10⁻⁴ · I + 25 nA"},{"name":"5 kHz to 10 kHz","range":"0,2 mA to 2 mA","cmc":"3,2·10⁻⁴ · I + 0,25 µA"},{"name":"5 kHz to 10 kHz","range":"2 mA to 20 mA","cmc":"3,2·10⁻⁴ · I + 2,5 µA"},{"name":"5 kHz to 10 kHz","range":"20 mA to 200 mA","cmc":"3,0·10⁻⁴ · I + 22 µA"},{"name":"5 kHz to 10 kHz","range":"0,2 A to 2 A","cmc":"8,0·10⁻⁴ · I + 0,25 mA"},{"name":"5 kHz to 10 kHz","range":"2 A to 3,1 A","cmc":"2,2·10⁻³ · I + 0,7 mA"},{"name":"5 kHz to 10 kHz","range":"3,1 A to 12 A","cmc":"2,2·10⁻³ · I + 1,2 mA"},{"name":"10 kHz to 20 kHz","range":"10 µA to 200 µA","cmc":"7,5·10⁻⁴ · I + 25 nA"},{"name":"10 kHz to 20 kHz","range":"0,2 mA to 2 mA","cmc":"7,5·10⁻⁴ · I + 0,25 µA"},{"name":"10 kHz to 20 kHz","range":"2 mA to 20 mA","cmc":"7,5·10⁻⁴ · I + 2,5 µA"},{"name":"10 kHz to 20 kHz","range":"20 mA to 200 mA","cmc":"7,0·10⁻⁴ · I + 23 µA"},{"name":"10 kHz to 20 kHz","range":"0,2 A to 2 A","cmc":"3,3·10⁻³ · I + 0,6 mA"},{"name":"45 Hz to 400 Hz","range":"10 A to 100 A","cmc":"0,065 %"},{"name":"45 Hz to 400 Hz","range":"100 A to 1000 A","cmc":"0,2 %"},{"name":"400 Hz to 1 kHz","range":"10 A to 100 A","cmc":"0,08 %"},{"name":"50 Hz to 60 Hz","range":"100 A to 500 A","cmc":"0,05 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct and indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 40 Hz 10 µA do 200 µA CMC 2,0·10⁻⁴ · I + 15 nA\n10 Hz do 40 Hz 0,2 mA do 2 mA CMC 2,0·10⁻⁴ · I + 0,1 µA\n10 Hz do 40 Hz 2 mA do 20 mA CMC 2,0·10⁻⁴ · I + 1 µA\n10 Hz do 40 Hz 20 mA do 200 mA CMC 2,0·10⁻⁴ · I + 10 µA\n10 Hz do 45 Hz 0,2 A do 1,2 A CMC 2,0·10⁻⁴ · I + 0,14 mA\n10 Hz do 45 Hz 1,2 A do 3,1 A CMC 2,5·10⁻⁴ · I + 0,9 mA\n10 Hz do 45 Hz 3,1 A do 12 A CMC 3,5·10⁻⁴ · I + 1,1 mA\n10 Hz do 45 Hz 12 A do 30 A CMC 6,0·10⁻⁴ · I + 20 mA\n40 Hz do 1 kHz 10 µA do 220 µA CMC 1,2·10⁻⁴ · I + 10 nA\n40 Hz do 1 kHz 0,22 mA do 2,2 mA CMC 1,2·10⁻⁴ · I + 40 nA\n40 Hz do 1 kHz 2,2 mA do 22 mA CMC 1,2·10⁻⁴ · I + 0,4 µA\n40 Hz do 1 kHz 22 mA do 220 mA CMC 1,2·10⁻⁴ · I + 3 µA\n45 Hz do 1 kHz 0,22 A do 1,2 A CMC 2,0·10⁻⁴ · I + 0,07 mA\n45 Hz do 1 kHz 1,2 A do 3,1 A CMC 2,0·10⁻⁴ · I + 0,5 mA\n45 Hz do 1 kHz 3,1 A do 12 A CMC 3,0·10⁻⁴ · I + 0,8 mA\n45 Hz do 1 kHz 12 A do 30 A CMC 4,0·10⁻⁴ · I + 15 mA\n1 kHz do 5 kHz 10 µA do 120 µA CMC 2,0·10⁻⁴ · I + 13 nA\n1 kHz do 5 kHz 0,12 mA do 1,2 mA CMC 2,0·10⁻⁴ · I + 0,1 µA\n1 kHz do 5 kHz 1,2 mA do 12 mA CMC 2,0·10⁻⁴ · I + 1 µA\n1 kHz do 5 kHz 12 mA do 120 mA CMC 2,2·10⁻⁴ · I + 9 µA\n1 kHz do 5 kHz 0,12 A do 1,2 A CMC 2,2·10⁻⁴ · I + 0,1 mA\n1 kHz do 5 kHz 1,2 A do 3,1 A CMC 2,2·10⁻⁴ · I + 0,7 mA\n1 kHz do 5 kHz 3,1 A do 12 A CMC 3,3·10⁻⁴ · I + 1 mA\n1 kHz do 5 kHz 12 A do 30 A CMC 4,0·10⁻³ · I + 20 mA\n5 kHz do 10 kHz 10 µA do 200 µA CMC 5,4·10⁻⁴ · I + 25 nA\n5 kHz do 10 kHz 0,2 mA do 2 mA CMC 3,2·10⁻⁴ · I + 0,25 µA\n5 kHz do 10 kHz 2 mA do 20 mA CMC 3,2·10⁻⁴ · I + 2,5 µA\n5 kHz do 10 kHz 20 mA do 200 mA CMC 3,0·10⁻⁴ · I + 22 µA\n5 kHz do 10 kHz 0,2 A do 2 A CMC 8,0·10⁻⁴ · I + 0,25 mA\n5 kHz do 10 kHz 2 A do 3,1 A CMC 2,2·10⁻³ · I + 0,7 mA\n5 kHz do 10 kHz 3,1 A do 12 A CMC 2,2·10⁻³ · I + 1,2 mA\n10 kHz do 20 kHz 10 µA do 200 µA CMC 7,5·10⁻⁴ · I + 25 nA\n10 kHz do 20 kHz 0,2 mA do 2 mA CMC 7,5·10⁻⁴ · I + 0,25 µA\n10 kHz do 20 kHz 2 mA do 20 mA CMC 7,5·10⁻⁴ · I + 2,5 µA\n10 kHz do 20 kHz 20 mA do 200 mA CMC 7,0·10⁻⁴ · I + 23 µA\n10 kHz do 20 kHz 0,2 A do 2 A CMC 3,3·10⁻³ · I + 0,6 mA\n45 Hz do 400 Hz 10 A do 100 A CMC 0,065 %\n45 Hz do 400 Hz 100 A do 1000 A CMC 0,2 %\n400 Hz do 1 kHz 10 A do 100 A CMC 0,08 %\n50 Hz do 60 Hz 100 A do 500 A CMC 0,05 %\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/3\nLMEEiO/5\nLMEEiO/28","norm_bases":["LMEEiO/3","LMEEiO/5","LMEEiO/28"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Kalibratory\nKarty pomiarowe\nSymulatory prądu upływu\nZasilacze\nMostki\nTestery bezpieczeństwa elektrycznego\nMierniki parametrów sieci Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 40 Hz 10 µA do 200 µA CMC 2,0·10⁻⁴ · I + 15 nA\n10 Hz do 40 Hz 0,2 mA do 2 mA CMC 2,0·10⁻⁴ · I + 0,1 µA\n10 Hz do 40 Hz 2 mA do 20 mA CMC 2,0·10⁻⁴ · I + 1 µA\n10 Hz do 40 Hz 20 mA do 200 mA CMC 2,0·10⁻⁴ · I + 10 µA\n10 Hz do 45 Hz 0,2 A do 1,2 A CMC 2,0·10⁻⁴ · I + 0,14 mA\n10 Hz do 45 Hz 1,2 A do 3,1 A CMC 2,5·10⁻⁴ · I + 0,9 mA\n10 Hz do 45 Hz 3,1 A do 12 A CMC 3,5·10⁻⁴ · I + 1,1 mA\n10 Hz do 45 Hz 12 A do 30 A CMC 6,0·10⁻⁴ · I + 20 mA\n40 Hz do 1 kHz 10 µA do 220 µA CMC 1,2·10⁻⁴ · I + 10 nA\n40 Hz do 1 kHz 0,22 mA do 2,2 mA CMC 1,2·10⁻⁴ · I + 40 nA\n40 Hz do 1 kHz 2,2 mA do 22 mA CMC 1,2·10⁻⁴ · I + 0,4 µA\n40 Hz do 1 kHz 22 mA do 220 mA CMC 1,2·10⁻⁴ · I + 3 µA\n45 Hz do 1 kHz 0,22 A do 1,2 A CMC 2,0·10⁻⁴ · I + 0,07 mA\n45 Hz do 1 kHz 1,2 A do 3,1 A CMC 2,0·10⁻⁴ · I + 0,5 mA\n45 Hz do 1 kHz 3,1 A do 12 A CMC 3,0·10⁻⁴ · I + 0,8 mA\n45 Hz do 1 kHz 12 A do 30 A CMC 4,0·10⁻⁴ · I + 15 mA\n1 kHz do 5 kHz 10 µA do 120 µA CMC 2,0·10⁻⁴ · I + 13 nA\n1 kHz do 5 kHz 0,12 mA do 1,2 mA CMC 2,0·10⁻⁴ · I + 0,1 µA\n1 kHz do 5 kHz 1,2 mA do 12 mA CMC 2,0·10⁻⁴ · I + 1 µA\n1 kHz do 5 kHz 12 mA do 120 mA CMC 2,2·10⁻⁴ · I + 9 µA\n1 kHz do 5 kHz 0,12 A do 1,2 A CMC 2,2·10⁻⁴ · I + 0,1 mA\n1 kHz do 5 kHz 1,2 A do 3,1 A CMC 2,2·10⁻⁴ · I + 0,7 mA\n1 kHz do 5 kHz 3,1 A do 12 A CMC 3,3·10⁻⁴ · I + 1 mA\n1 kHz do 5 kHz 12 A do 30 A CMC 4,0·10⁻³ · I + 20 mA\n5 kHz do 10 kHz 10 µA do 200 µA CMC 5,4·10⁻⁴ · I + 25 nA\n5 kHz do 10 kHz 0,2 mA do 2 mA CMC 3,2·10⁻⁴ · I + 0,25 µA\n5 kHz do 10 kHz 2 mA do 20 mA CMC 3,2·10⁻⁴ · I + 2,5 µA\n5 kHz do 10 kHz 20 mA do 200 mA CMC 3,0·10⁻⁴ · I + 22 µA\n5 kHz do 10 kHz 0,2 A do 2 A CMC 8,0·10⁻⁴ · I + 0,25 mA\n5 kHz do 10 kHz 2 A do 3,1 A CMC 2,2·10⁻³ · I + 0,7 mA\n5 kHz do 10 kHz 3,1 A do 12 A CMC 2,2·10⁻³ · I + 1,2 mA\n10 kHz do 20 kHz 10 µA do 200 µA CMC 7,5·10⁻⁴ · I + 25 nA\n10 kHz do 20 kHz 0,2 mA do 2 mA CMC 7,5·10⁻⁴ · I + 0,25 µA\n10 kHz do 20 kHz 2 mA do 20 mA CMC 7,5·10⁻⁴ · I + 2,5 µA\n10 kHz do 20 kHz 20 mA do 200 mA CMC 7,0·10⁻⁴ · I + 23 µA\n10 kHz do 20 kHz 0,2 A do 2 A CMC 3,3·10⁻³ · I + 0,6 mA\n45 Hz do 400 Hz 10 A do 100 A CMC 0,065 %\n45 Hz do 400 Hz 100 A do 1000 A CMC 0,2 %\n400 Hz do 1 kHz 10 A do 100 A CMC 0,08 %\n50 Hz do 60 Hz 100 A do 500 A CMC 0,05 %\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/3\nLMEEiO/5\nLMEEiO/28 Kalibratory\nKarty pomiarowe\nSymulatory pradu uplywu\nZasilacze\nMostki\nTestery bezpieczenstwa elektrycznego\nMierniki parametrow sieci Wzorcowanie — Prad AC\nZakres:\n10 Hz do 40 Hz 10 µA do 200 µA CMC 2,0·10⁻⁴ · I + 15 nA\n10 Hz do 40 Hz 0,2 mA do 2 mA CMC 2,0·10⁻⁴ · I + 0,1 µA\n10 Hz do 40 Hz 2 mA do 20 mA CMC 2,0·10⁻⁴ · I + 1 µA\n10 Hz do 40 Hz 20 mA do 200 mA CMC 2,0·10⁻⁴ · I + 10 µA\n10 Hz do 45 Hz 0,2 A do 1,2 A CMC 2,0·10⁻⁴ · I + 0,14 mA\n10 Hz do 45 Hz 1,2 A do 3,1 A CMC 2,5·10⁻⁴ · I + 0,9 mA\n10 Hz do 45 Hz 3,1 A do 12 A CMC 3,5·10⁻⁴ · I + 1,1 mA\n10 Hz do 45 Hz 12 A do 30 A CMC 6,0·10⁻⁴ · I + 20 mA\n40 Hz do 1 kHz 10 µA do 220 µA CMC 1,2·10⁻⁴ · I + 10 nA\n40 Hz do 1 kHz 0,22 mA do 2,2 mA CMC 1,2·10⁻⁴ · I + 40 nA\n40 Hz do 1 kHz 2,2 mA do 22 mA CMC 1,2·10⁻⁴ · I + 0,4 µA\n40 Hz do 1 kHz 22 mA do 220 mA CMC 1,2·10⁻⁴ · I + 3 µA\n45 Hz do 1 kHz 0,22 A do 1,2 A CMC 2,0·10⁻⁴ · I + 0,07 mA\n45 Hz do 1 kHz 1,2 A do 3,1 A CMC 2,0·10⁻⁴ · I + 0,5 mA\n45 Hz do 1 kHz 3,1 A do 12 A CMC 3,0·10⁻⁴ · I + 0,8 mA\n45 Hz do 1 kHz 12 A do 30 A CMC 4,0·10⁻⁴ · I + 15 mA\n1 kHz do 5 kHz 10 µA do 120 µA CMC 2,0·10⁻⁴ · I + 13 nA\n1 kHz do 5 kHz 0,12 mA do 1,2 mA CMC 2,0·10⁻⁴ · I + 0,1 µA\n1 kHz do 5 kHz 1,2 mA do 12 mA CMC 2,0·10⁻⁴ · I + 1 µA\n1 kHz do 5 kHz 12 mA do 120 mA CMC 2,2·10⁻⁴ · I + 9 µA\n1 kHz do 5 kHz 0,12 A do 1,2 A CMC 2,2·10⁻⁴ · I + 0,1 mA\n1 kHz do 5 kHz 1,2 A do 3,1 A CMC 2,2·10⁻⁴ · I + 0,7 mA\n1 kHz do 5 kHz 3,1 A do 12 A CMC 3,3·10⁻⁴ · I + 1 mA\n1 kHz do 5 kHz 12 A do 30 A CMC 4,0·10⁻³ · I + 20 mA\n5 kHz do 10 kHz 10 µA do 200 µA CMC 5,4·10⁻⁴ · I + 25 nA\n5 kHz do 10 kHz 0,2 mA do 2 mA CMC 3,2·10⁻⁴ · I + 0,25 µA\n5 kHz do 10 kHz 2 mA do 20 mA CMC 3,2·10⁻⁴ · I + 2,5 µA\n5 kHz do 10 kHz 20 mA do 200 mA CMC 3,0·10⁻⁴ · I + 22 µA\n5 kHz do 10 kHz 0,2 A do 2 A CMC 8,0·10⁻⁴ · I + 0,25 mA\n5 kHz do 10 kHz 2 A do 3,1 A CMC 2,2·10⁻³ · I + 0,7 mA\n5 kHz do 10 kHz 3,1 A do 12 A CMC 2,2·10⁻³ · I + 1,2 mA\n10 kHz do 20 kHz 10 µA do 200 µA CMC 7,5·10⁻⁴ · I + 25 nA\n10 kHz do 20 kHz 0,2 mA do 2 mA CMC 7,5·10⁻⁴ · I + 0,25 µA\n10 kHz do 20 kHz 2 mA do 20 mA CMC 7,5·10⁻⁴ · I + 2,5 µA\n10 kHz do 20 kHz 20 mA do 200 mA CMC 7,0·10⁻⁴ · I + 23 µA\n10 kHz do 20 kHz 0,2 A do 2 A CMC 3,3·10⁻³ · I + 0,6 mA\n45 Hz do 400 Hz 10 A do 100 A CMC 0,065 %\n45 Hz do 400 Hz 100 A do 1000 A CMC 0,2 %\n400 Hz do 1 kHz 10 A do 100 A CMC 0,08 %\n50 Hz do 60 Hz 100 A do 500 A CMC 0,05 %\nProcedura wewnetrzna; Metoda bezposrednia i posrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/3\nLMEEiO/5\nLMEEiO/28","search_en":"Calibrators Data acquisition cards Leakage current simulators Power supplies Bridges Electrical safety testers Power network parameter meters Calibration — AC current Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) AC current Internal procedure Direct and indirect method At permanent location (S) and outside of it (P) 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 45 Hz 10 Hz to 45 Hz 10 Hz to 45 Hz 10 Hz to 45 Hz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 10 kHz to 20 kHz 10 kHz to 20 kHz 10 kHz to 20 kHz 10 kHz to 20 kHz 10 kHz to 20 kHz 45 Hz to 400 Hz 45 Hz to 400 Hz 400 Hz to 1 kHz 50 Hz to 60 Hz LMEEiO/3 LMEEiO/5 LMEEiO/28","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"10 Hz bis 40 Hz","range":"10 µA to 200 µA","cmc":"2,0·10⁻⁴ · I + 15 nA"},{"name":"10 Hz bis 40 Hz","range":"0,2 mA to 2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"10 Hz bis 40 Hz","range":"2 mA to 20 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"10 Hz bis 40 Hz","range":"20 mA to 200 mA","cmc":"2,0·10⁻⁴ · I + 10 µA"},{"name":"10 Hz bis 45 Hz","range":"0,2 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,14 mA"},{"name":"10 Hz bis 45 Hz","range":"1,2 A to 3,1 A","cmc":"2,5·10⁻⁴ · I + 0,9 mA"},{"name":"10 Hz bis 45 Hz","range":"3,1 A to 12 A","cmc":"3,5·10⁻⁴ · I + 1,1 mA"},{"name":"10 Hz bis 45 Hz","range":"12 A to 30 A","cmc":"6,0·10⁻⁴ · I + 20 mA"},{"name":"40 Hz bis 1 kHz","range":"10 µA to 220 µA","cmc":"1,2·10⁻⁴ · I + 10 nA"},{"name":"40 Hz bis 1 kHz","range":"0,22 mA to 2,2 mA","cmc":"1,2·10⁻⁴ · I + 40 nA"},{"name":"40 Hz bis 1 kHz","range":"2,2 mA to 22 mA","cmc":"1,2·10⁻⁴ · I + 0,4 µA"},{"name":"40 Hz bis 1 kHz","range":"22 mA to 220 mA","cmc":"1,2·10⁻⁴ · I + 3 µA"},{"name":"45 Hz bis 1 kHz","range":"0,22 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,07 mA"},{"name":"45 Hz bis 1 kHz","range":"1,2 A to 3,1 A","cmc":"2,0·10⁻⁴ · I + 0,5 mA"},{"name":"45 Hz bis 1 kHz","range":"3,1 A to 12 A","cmc":"3,0·10⁻⁴ · I + 0,8 mA"},{"name":"45 Hz bis 1 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻⁴ · I + 15 mA"},{"name":"1 kHz bis 5 kHz","range":"10 µA to 120 µA","cmc":"2,0·10⁻⁴ · I + 13 nA"},{"name":"1 kHz bis 5 kHz","range":"0,12 mA to 1,2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"1 kHz bis 5 kHz","range":"1,2 mA to 12 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"1 kHz bis 5 kHz","range":"12 mA to 120 mA","cmc":"2,2·10⁻⁴ · I + 9 µA"},{"name":"1 kHz bis 5 kHz","range":"0,12 A to 1,2 A","cmc":"2,2·10⁻⁴ · I + 0,1 mA"},{"name":"1 kHz bis 5 kHz","range":"1,2 A to 3,1 A","cmc":"2,2·10⁻⁴ · I + 0,7 mA"},{"name":"1 kHz bis 5 kHz","range":"3,1 A to 12 A","cmc":"3,3·10⁻⁴ · I + 1 mA"},{"name":"1 kHz bis 5 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻³ · I + 20 mA"},{"name":"5 kHz bis 10 kHz","range":"10 µA to 200 µA","cmc":"5,4·10⁻⁴ · I + 25 nA"},{"name":"5 kHz bis 10 kHz","range":"0,2 mA to 2 mA","cmc":"3,2·10⁻⁴ · I + 0,25 µA"},{"name":"5 kHz bis 10 kHz","range":"2 mA to 20 mA","cmc":"3,2·10⁻⁴ · I + 2,5 µA"},{"name":"5 kHz bis 10 kHz","range":"20 mA to 200 mA","cmc":"3,0·10⁻⁴ · I + 22 µA"},{"name":"5 kHz bis 10 kHz","range":"0,2 A to 2 A","cmc":"8,0·10⁻⁴ · I + 0,25 mA"},{"name":"5 kHz bis 10 kHz","range":"2 A to 3,1 A","cmc":"2,2·10⁻³ · I + 0,7 mA"},{"name":"5 kHz bis 10 kHz","range":"3,1 A to 12 A","cmc":"2,2·10⁻³ · I + 1,2 mA"},{"name":"10 kHz bis 20 kHz","range":"10 µA to 200 µA","cmc":"7,5·10⁻⁴ · I + 25 nA"},{"name":"10 kHz bis 20 kHz","range":"0,2 mA to 2 mA","cmc":"7,5·10⁻⁴ · I + 0,25 µA"},{"name":"10 kHz bis 20 kHz","range":"2 mA to 20 mA","cmc":"7,5·10⁻⁴ · I + 2,5 µA"},{"name":"10 kHz bis 20 kHz","range":"20 mA to 200 mA","cmc":"7,0·10⁻⁴ · I + 23 µA"},{"name":"10 kHz bis 20 kHz","range":"0,2 A to 2 A","cmc":"3,3·10⁻³ · I + 0,6 mA"},{"name":"45 Hz bis 400 Hz","range":"10 A to 100 A","cmc":"0,065 %"},{"name":"45 Hz bis 400 Hz","range":"100 A to 1000 A","cmc":"0,2 %"},{"name":"400 Hz bis 1 kHz","range":"10 A to 100 A","cmc":"0,08 %"},{"name":"50 Hz bis 60 Hz","range":"100 A to 500 A","cmc":"0,05 %"}],"regulatory_area_de":"AC-Strom","search_de":"Kalibratoren Messkarten Ableitstromsimulatoren Netzgeräte Messbrücken Prüfgeräte für elektrische Sicherheit Netzparametermessgeräte Kalibrierung — Wechselstrom Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Strom Internes Verfahren Direktes und indirektes Verfahren Am festen Standort (S) und außerhalb (P) 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 45 Hz 10 Hz bis 45 Hz 10 Hz bis 45 Hz 10 Hz bis 45 Hz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 45 Hz bis 1 kHz 45 Hz bis 1 kHz 45 Hz bis 1 kHz 45 Hz bis 1 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 10 kHz bis 20 kHz 10 kHz bis 20 kHz 10 kHz bis 20 kHz 10 kHz bis 20 kHz 10 kHz bis 20 kHz 45 Hz bis 400 Hz 45 Hz bis 400 Hz 400 Hz bis 1 kHz 50 Hz bis 60 Hz LMEEiO/3 LMEEiO/5 LMEEiO/28","technique_de":"Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes und indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nMesskarten\nAbleitstromsimulatoren\nNetzgeräte\nMessbrücken\nPrüfgeräte für elektrische Sicherheit\nNetzparametermessgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"10 µA to 200 µA","cmc":"2,0·10⁻⁴ · I + 15 nA"},{"name":"10 Hz 至 40 Hz","range":"0,2 mA to 2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"10 Hz 至 40 Hz","range":"2 mA to 20 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"10 Hz 至 40 Hz","range":"20 mA to 200 mA","cmc":"2,0·10⁻⁴ · I + 10 µA"},{"name":"10 Hz 至 45 Hz","range":"0,2 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,14 mA"},{"name":"10 Hz 至 45 Hz","range":"1,2 A to 3,1 A","cmc":"2,5·10⁻⁴ · I + 0,9 mA"},{"name":"10 Hz 至 45 Hz","range":"3,1 A to 12 A","cmc":"3,5·10⁻⁴ · I + 1,1 mA"},{"name":"10 Hz 至 45 Hz","range":"12 A to 30 A","cmc":"6,0·10⁻⁴ · I + 20 mA"},{"name":"40 Hz 至 1 kHz","range":"10 µA to 220 µA","cmc":"1,2·10⁻⁴ · I + 10 nA"},{"name":"40 Hz 至 1 kHz","range":"0,22 mA to 2,2 mA","cmc":"1,2·10⁻⁴ · I + 40 nA"},{"name":"40 Hz 至 1 kHz","range":"2,2 mA to 22 mA","cmc":"1,2·10⁻⁴ · I + 0,4 µA"},{"name":"40 Hz 至 1 kHz","range":"22 mA to 220 mA","cmc":"1,2·10⁻⁴ · I + 3 µA"},{"name":"45 Hz 至 1 kHz","range":"0,22 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,07 mA"},{"name":"45 Hz 至 1 kHz","range":"1,2 A to 3,1 A","cmc":"2,0·10⁻⁴ · I + 0,5 mA"},{"name":"45 Hz 至 1 kHz","range":"3,1 A to 12 A","cmc":"3,0·10⁻⁴ · I + 0,8 mA"},{"name":"45 Hz 至 1 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻⁴ · I + 15 mA"},{"name":"1 kHz 至 5 kHz","range":"10 µA to 120 µA","cmc":"2,0·10⁻⁴ · I + 13 nA"},{"name":"1 kHz 至 5 kHz","range":"0,12 mA to 1,2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"1 kHz 至 5 kHz","range":"1,2 mA to 12 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"1 kHz 至 5 kHz","range":"12 mA to 120 mA","cmc":"2,2·10⁻⁴ · I + 9 µA"},{"name":"1 kHz 至 5 kHz","range":"0,12 A to 1,2 A","cmc":"2,2·10⁻⁴ · I + 0,1 mA"},{"name":"1 kHz 至 5 kHz","range":"1,2 A to 3,1 A","cmc":"2,2·10⁻⁴ · I + 0,7 mA"},{"name":"1 kHz 至 5 kHz","range":"3,1 A to 12 A","cmc":"3,3·10⁻⁴ · I + 1 mA"},{"name":"1 kHz 至 5 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻³ · I + 20 mA"},{"name":"5 kHz 至 10 kHz","range":"10 µA to 200 µA","cmc":"5,4·10⁻⁴ · I + 25 nA"},{"name":"5 kHz 至 10 kHz","range":"0,2 mA to 2 mA","cmc":"3,2·10⁻⁴ · I + 0,25 µA"},{"name":"5 kHz 至 10 kHz","range":"2 mA to 20 mA","cmc":"3,2·10⁻⁴ · I + 2,5 µA"},{"name":"5 kHz 至 10 kHz","range":"20 mA to 200 mA","cmc":"3,0·10⁻⁴ · I + 22 µA"},{"name":"5 kHz 至 10 kHz","range":"0,2 A to 2 A","cmc":"8,0·10⁻⁴ · I + 0,25 mA"},{"name":"5 kHz 至 10 kHz","range":"2 A to 3,1 A","cmc":"2,2·10⁻³ · I + 0,7 mA"},{"name":"5 kHz 至 10 kHz","range":"3,1 A to 12 A","cmc":"2,2·10⁻³ · I + 1,2 mA"},{"name":"10 kHz 至 20 kHz","range":"10 µA to 200 µA","cmc":"7,5·10⁻⁴ · I + 25 nA"},{"name":"10 kHz 至 20 kHz","range":"0,2 mA to 2 mA","cmc":"7,5·10⁻⁴ · I + 0,25 µA"},{"name":"10 kHz 至 20 kHz","range":"2 mA to 20 mA","cmc":"7,5·10⁻⁴ · I + 2,5 µA"},{"name":"10 kHz 至 20 kHz","range":"20 mA to 200 mA","cmc":"7,0·10⁻⁴ · I + 23 µA"},{"name":"10 kHz 至 20 kHz","range":"0,2 A to 2 A","cmc":"3,3·10⁻³ · I + 0,6 mA"},{"name":"45 Hz 至 400 Hz","range":"10 A to 100 A","cmc":"0,065 %"},{"name":"45 Hz 至 400 Hz","range":"100 A to 1000 A","cmc":"0,2 %"},{"name":"400 Hz 至 1 kHz","range":"10 A to 100 A","cmc":"0,08 %"},{"name":"50 Hz 至 60 Hz","range":"100 A to 500 A","cmc":"0,05 %"}],"regulatory_area_zh":"交流电流","search_zh":"校准器 测量卡 泄漏电流模拟器 电源 电桥 电气安全测试仪 电网参数测量仪 校准 — 交流电流 内部程序；直接法和间接法；在固定地点 (S) 及固定地点以外 (P) 交流电流 内部程序 直接法和间接法 在固定地点 (S) 及固定地点以外 (P) 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 45 Hz 10 Hz 至 45 Hz 10 Hz 至 45 Hz 10 Hz 至 45 Hz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 45 Hz 至 1 kHz 45 Hz 至 1 kHz 45 Hz 至 1 kHz 45 Hz 至 1 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 10 kHz 至 20 kHz 10 kHz 至 20 kHz 10 kHz 至 20 kHz 10 kHz 至 20 kHz 10 kHz 至 20 kHz 45 Hz 至 400 Hz 45 Hz 至 400 Hz 400 Hz 至 1 kHz 50 Hz 至 60 Hz LMEEiO/3 LMEEiO/5 LMEEiO/28","technique_zh":"内部程序；直接法和间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法和间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n测量卡\n泄漏电流模拟器\n电源\n电桥\n电气安全测试仪\n电网参数测量仪","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"10 Hz až 40 Hz","range":"10 µA to 200 µA","cmc":"2,0·10⁻⁴ · I + 15 nA"},{"name":"10 Hz až 40 Hz","range":"0,2 mA to 2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"10 Hz až 40 Hz","range":"2 mA to 20 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"10 Hz až 40 Hz","range":"20 mA to 200 mA","cmc":"2,0·10⁻⁴ · I + 10 µA"},{"name":"10 Hz až 45 Hz","range":"0,2 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,14 mA"},{"name":"10 Hz až 45 Hz","range":"1,2 A to 3,1 A","cmc":"2,5·10⁻⁴ · I + 0,9 mA"},{"name":"10 Hz až 45 Hz","range":"3,1 A to 12 A","cmc":"3,5·10⁻⁴ · I + 1,1 mA"},{"name":"10 Hz až 45 Hz","range":"12 A to 30 A","cmc":"6,0·10⁻⁴ · I + 20 mA"},{"name":"40 Hz až 1 kHz","range":"10 µA to 220 µA","cmc":"1,2·10⁻⁴ · I + 10 nA"},{"name":"40 Hz až 1 kHz","range":"0,22 mA to 2,2 mA","cmc":"1,2·10⁻⁴ · I + 40 nA"},{"name":"40 Hz až 1 kHz","range":"2,2 mA to 22 mA","cmc":"1,2·10⁻⁴ · I + 0,4 µA"},{"name":"40 Hz až 1 kHz","range":"22 mA to 220 mA","cmc":"1,2·10⁻⁴ · I + 3 µA"},{"name":"45 Hz až 1 kHz","range":"0,22 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,07 mA"},{"name":"45 Hz až 1 kHz","range":"1,2 A to 3,1 A","cmc":"2,0·10⁻⁴ · I + 0,5 mA"},{"name":"45 Hz až 1 kHz","range":"3,1 A to 12 A","cmc":"3,0·10⁻⁴ · I + 0,8 mA"},{"name":"45 Hz až 1 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻⁴ · I + 15 mA"},{"name":"1 kHz až 5 kHz","range":"10 µA to 120 µA","cmc":"2,0·10⁻⁴ · I + 13 nA"},{"name":"1 kHz až 5 kHz","range":"0,12 mA to 1,2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"1 kHz až 5 kHz","range":"1,2 mA to 12 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"1 kHz až 5 kHz","range":"12 mA to 120 mA","cmc":"2,2·10⁻⁴ · I + 9 µA"},{"name":"1 kHz až 5 kHz","range":"0,12 A to 1,2 A","cmc":"2,2·10⁻⁴ · I + 0,1 mA"},{"name":"1 kHz až 5 kHz","range":"1,2 A to 3,1 A","cmc":"2,2·10⁻⁴ · I + 0,7 mA"},{"name":"1 kHz až 5 kHz","range":"3,1 A to 12 A","cmc":"3,3·10⁻⁴ · I + 1 mA"},{"name":"1 kHz až 5 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻³ · I + 20 mA"},{"name":"5 kHz až 10 kHz","range":"10 µA to 200 µA","cmc":"5,4·10⁻⁴ · I + 25 nA"},{"name":"5 kHz až 10 kHz","range":"0,2 mA to 2 mA","cmc":"3,2·10⁻⁴ · I + 0,25 µA"},{"name":"5 kHz až 10 kHz","range":"2 mA to 20 mA","cmc":"3,2·10⁻⁴ · I + 2,5 µA"},{"name":"5 kHz až 10 kHz","range":"20 mA to 200 mA","cmc":"3,0·10⁻⁴ · I + 22 µA"},{"name":"5 kHz až 10 kHz","range":"0,2 A to 2 A","cmc":"8,0·10⁻⁴ · I + 0,25 mA"},{"name":"5 kHz až 10 kHz","range":"2 A to 3,1 A","cmc":"2,2·10⁻³ · I + 0,7 mA"},{"name":"5 kHz až 10 kHz","range":"3,1 A to 12 A","cmc":"2,2·10⁻³ · I + 1,2 mA"},{"name":"10 kHz až 20 kHz","range":"10 µA to 200 µA","cmc":"7,5·10⁻⁴ · I + 25 nA"},{"name":"10 kHz až 20 kHz","range":"0,2 mA to 2 mA","cmc":"7,5·10⁻⁴ · I + 0,25 µA"},{"name":"10 kHz až 20 kHz","range":"2 mA to 20 mA","cmc":"7,5·10⁻⁴ · I + 2,5 µA"},{"name":"10 kHz až 20 kHz","range":"20 mA to 200 mA","cmc":"7,0·10⁻⁴ · I + 23 µA"},{"name":"10 kHz až 20 kHz","range":"0,2 A to 2 A","cmc":"3,3·10⁻³ · I + 0,6 mA"},{"name":"45 Hz až 400 Hz","range":"10 A to 100 A","cmc":"0,065 %"},{"name":"45 Hz až 400 Hz","range":"100 A to 1000 A","cmc":"0,2 %"},{"name":"400 Hz až 1 kHz","range":"10 A to 100 A","cmc":"0,08 %"},{"name":"50 Hz až 60 Hz","range":"100 A to 500 A","cmc":"0,05 %"}],"regulatory_area_cs":"Proud AC","search_cs":"Kalibrátory Měřicí karty Simulátory unikajícího proudu Napájecí zdroje Můstky Testery elektrické bezpečnosti Měřiče parametrů sítě Kalibrace — Proud AC Vnitřní postup; Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P) Proud AC Vnitřní postup Přímá a nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 45 Hz 10 Hz až 45 Hz 10 Hz až 45 Hz 10 Hz až 45 Hz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 45 Hz až 1 kHz 45 Hz až 1 kHz 45 Hz až 1 kHz 45 Hz až 1 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 10 kHz až 20 kHz 10 kHz až 20 kHz 10 kHz až 20 kHz 10 kHz až 20 kHz 10 kHz až 20 kHz 45 Hz až 400 Hz 45 Hz až 400 Hz 400 Hz až 1 kHz 50 Hz až 60 Hz LMEEiO/3 LMEEiO/5 LMEEiO/28","technique_cs":"Vnitřní postup; Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá a nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nMěřicí karty\nSimulátory unikajícího proudu\nNapájecí zdroje\nMůstky\nTestery elektrické bezpečnosti\nMěřiče parametrů sítě"},{"_id":"4a67d1cf5641db310aa1fa78","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Multimetry\nMierniki prądu cyfrowe\nMierniki prądu analogowe\nKarty pomiarowe\nMierniki cęgowe\nTestery bezpieczeństwa elektrycznego\nMierniki parametrów sieci\nObciążenia elektroniczne\nSondy pomiarowe","test_object_en":"Multimeters\nDigital ammeters\nAnalogue ammeters\nData acquisition cards\nClamp meters\nElectrical safety testers\nPower network parameter meters\nElectronic loads\nMeasuring probes","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"10 Hz do 40 Hz","range":"10 µA do 200 µA","cmc":"2,0·10⁻⁴ · I + 15 nA"},{"name":"10 Hz do 40 Hz","range":"0,2 mA do 2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"10 Hz do 40 Hz","range":"2 mA do 20 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"10 Hz do 40 Hz","range":"20 mA do 200 mA","cmc":"2,0·10⁻⁴ · I + 10 µA"},{"name":"10 Hz do 45 Hz","range":"0,2 A do 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,14 mA"},{"name":"10 Hz do 45 Hz","range":"1,2 A do 3,1 A","cmc":"2,5·10⁻⁴ · I + 0,9 mA"},{"name":"10 Hz do 45 Hz","range":"3,1 A do 12 A","cmc":"3,5·10⁻⁴ · I + 1,1 mA"},{"name":"10 Hz do 45 Hz","range":"12 A do 30 A","cmc":"6,0·10⁻⁴ · I + 20 mA"},{"name":"40 Hz do 1 kHz","range":"10 µA do 220 µA","cmc":"1,2·10⁻⁴ · I + 10 nA"},{"name":"40 Hz do 1 kHz","range":"0,22 mA do 2,2 mA","cmc":"1,2·10⁻⁴ · I + 40 nA"},{"name":"40 Hz do 1 kHz","range":"2,2 mA do 22 mA","cmc":"1,2·10⁻⁴ · I + 0,4 µA"},{"name":"40 Hz do 1 kHz","range":"22 mA do 220 mA","cmc":"1,2·10⁻⁴ · I + 3 µA"},{"name":"45 Hz do 1 kHz","range":"0,22 A do 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,07 mA"},{"name":"45 Hz do 1 kHz","range":"1,2 A do 3,1 A","cmc":"2,0·10⁻⁴ · I + 0,5 mA"},{"name":"45 Hz do 1 kHz","range":"3,1 A do 12 A","cmc":"3,0·10⁻⁴ · I + 0,8 mA"},{"name":"45 Hz do 1 kHz","range":"12 A do 30 A","cmc":"4,0·10⁻⁴ · I + 15 mA"},{"name":"1 kHz do 5 kHz","range":"10 µA do 120 µA","cmc":"2,0·10⁻⁴ · I + 13 nA"},{"name":"1 kHz do 5 kHz","range":"0,12 mA do 1,2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"1 kHz do 5 kHz","range":"1,2 mA do 12 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"1 kHz do 5 kHz","range":"12 mA do 120 mA","cmc":"2,2·10⁻⁴ · I + 9 µA"},{"name":"1 kHz do 5 kHz","range":"0,12 A do 1,2 A","cmc":"2,2·10⁻⁴ · I + 0,1 mA"},{"name":"1 kHz do 5 kHz","range":"1,2 A do 3,1 A","cmc":"2,2·10⁻⁴ · I + 0,7 mA"},{"name":"1 kHz do 5 kHz","range":"3,1 A do 12 A","cmc":"3,3·10⁻⁴ · I + 1 mA"},{"name":"1 kHz do 5 kHz","range":"12 A do 30 A","cmc":"4,0·10⁻³ · I + 20 mA"},{"name":"5 kHz do 10 kHz","range":"10 µA do 200 µA","cmc":"5,4·10⁻⁴ · I + 25 nA"},{"name":"5 kHz do 10 kHz","range":"0,2 mA do 2 mA","cmc":"3,2·10⁻⁴ · I + 0,25 µA"},{"name":"5 kHz do 10 kHz","range":"2 mA do 20 mA","cmc":"3,2·10⁻⁴ · I + 2,5 µA"},{"name":"5 kHz do 10 kHz","range":"20 mA do 200 mA","cmc":"3,0·10⁻⁴ · I + 22 µA"},{"name":"5 kHz do 10 kHz","range":"0,2 A do 2 A","cmc":"8,0·10⁻⁴ · I + 0,25 mA"},{"name":"5 kHz do 10 kHz","range":"2 A do 3,1 A","cmc":"2,2·10⁻³ · I + 0,7 mA"},{"name":"5 kHz do 10 kHz","range":"3,1 A do 12 A","cmc":"2,2·10⁻³ · I + 1,2 mA"},{"name":"10 kHz do 20 kHz","range":"10 µA do 200 µA","cmc":"7,5·10⁻⁴ · I + 25 nA"},{"name":"10 kHz do 20 kHz","range":"0,2 mA do 2 mA","cmc":"7,5·10⁻⁴ · I + 0,25 µA"},{"name":"10 kHz do 20 kHz","range":"2 mA do 20 mA","cmc":"7,5·10⁻⁴ · I + 2,5 µA"},{"name":"10 kHz do 20 kHz","range":"20 mA do 200 mA","cmc":"7,0·10⁻⁴ · I + 23 µA"},{"name":"10 kHz do 20 kHz","range":"0,2 A do 2 A","cmc":"3,3·10⁻³ · I + 0,6 mA"},{"name":"45 Hz do 400 Hz","range":"10 A do 100 A","cmc":"0,065 %"},{"name":"45 Hz do 400 Hz","range":"100 A do 1000 A","cmc":"0,2 %"},{"name":"400 Hz do 1 kHz","range":"10 A do 100 A","cmc":"0,08 %"},{"name":"50 Hz do 60 Hz","range":"100 A do 500 A","cmc":"0,05 %"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"10 µA to 200 µA","cmc":"2,0·10⁻⁴ · I + 15 nA"},{"name":"10 Hz to 40 Hz","range":"0,2 mA to 2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"10 Hz to 40 Hz","range":"2 mA to 20 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"10 Hz to 40 Hz","range":"20 mA to 200 mA","cmc":"2,0·10⁻⁴ · I + 10 µA"},{"name":"10 Hz to 45 Hz","range":"0,2 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,14 mA"},{"name":"10 Hz to 45 Hz","range":"1,2 A to 3,1 A","cmc":"2,5·10⁻⁴ · I + 0,9 mA"},{"name":"10 Hz to 45 Hz","range":"3,1 A to 12 A","cmc":"3,5·10⁻⁴ · I + 1,1 mA"},{"name":"10 Hz to 45 Hz","range":"12 A to 30 A","cmc":"6,0·10⁻⁴ · I + 20 mA"},{"name":"40 Hz to 1 kHz","range":"10 µA to 220 µA","cmc":"1,2·10⁻⁴ · I + 10 nA"},{"name":"40 Hz to 1 kHz","range":"0,22 mA to 2,2 mA","cmc":"1,2·10⁻⁴ · I + 40 nA"},{"name":"40 Hz to 1 kHz","range":"2,2 mA to 22 mA","cmc":"1,2·10⁻⁴ · I + 0,4 µA"},{"name":"40 Hz to 1 kHz","range":"22 mA to 220 mA","cmc":"1,2·10⁻⁴ · I + 3 µA"},{"name":"45 Hz to 1 kHz","range":"0,22 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,07 mA"},{"name":"45 Hz to 1 kHz","range":"1,2 A to 3,1 A","cmc":"2,0·10⁻⁴ · I + 0,5 mA"},{"name":"45 Hz to 1 kHz","range":"3,1 A to 12 A","cmc":"3,0·10⁻⁴ · I + 0,8 mA"},{"name":"45 Hz to 1 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻⁴ · I + 15 mA"},{"name":"1 kHz to 5 kHz","range":"10 µA to 120 µA","cmc":"2,0·10⁻⁴ · I + 13 nA"},{"name":"1 kHz to 5 kHz","range":"0,12 mA to 1,2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"1 kHz to 5 kHz","range":"1,2 mA to 12 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"1 kHz to 5 kHz","range":"12 mA to 120 mA","cmc":"2,2·10⁻⁴ · I + 9 µA"},{"name":"1 kHz to 5 kHz","range":"0,12 A to 1,2 A","cmc":"2,2·10⁻⁴ · I + 0,1 mA"},{"name":"1 kHz to 5 kHz","range":"1,2 A to 3,1 A","cmc":"2,2·10⁻⁴ · I + 0,7 mA"},{"name":"1 kHz to 5 kHz","range":"3,1 A to 12 A","cmc":"3,3·10⁻⁴ · I + 1 mA"},{"name":"1 kHz to 5 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻³ · I + 20 mA"},{"name":"5 kHz to 10 kHz","range":"10 µA to 200 µA","cmc":"5,4·10⁻⁴ · I + 25 nA"},{"name":"5 kHz to 10 kHz","range":"0,2 mA to 2 mA","cmc":"3,2·10⁻⁴ · I + 0,25 µA"},{"name":"5 kHz to 10 kHz","range":"2 mA to 20 mA","cmc":"3,2·10⁻⁴ · I + 2,5 µA"},{"name":"5 kHz to 10 kHz","range":"20 mA to 200 mA","cmc":"3,0·10⁻⁴ · I + 22 µA"},{"name":"5 kHz to 10 kHz","range":"0,2 A to 2 A","cmc":"8,0·10⁻⁴ · I + 0,25 mA"},{"name":"5 kHz to 10 kHz","range":"2 A to 3,1 A","cmc":"2,2·10⁻³ · I + 0,7 mA"},{"name":"5 kHz to 10 kHz","range":"3,1 A to 12 A","cmc":"2,2·10⁻³ · I + 1,2 mA"},{"name":"10 kHz to 20 kHz","range":"10 µA to 200 µA","cmc":"7,5·10⁻⁴ · I + 25 nA"},{"name":"10 kHz to 20 kHz","range":"0,2 mA to 2 mA","cmc":"7,5·10⁻⁴ · I + 0,25 µA"},{"name":"10 kHz to 20 kHz","range":"2 mA to 20 mA","cmc":"7,5·10⁻⁴ · I + 2,5 µA"},{"name":"10 kHz to 20 kHz","range":"20 mA to 200 mA","cmc":"7,0·10⁻⁴ · I + 23 µA"},{"name":"10 kHz to 20 kHz","range":"0,2 A to 2 A","cmc":"3,3·10⁻³ · I + 0,6 mA"},{"name":"45 Hz to 400 Hz","range":"10 A to 100 A","cmc":"0,065 %"},{"name":"45 Hz to 400 Hz","range":"100 A to 1000 A","cmc":"0,2 %"},{"name":"400 Hz to 1 kHz","range":"10 A to 100 A","cmc":"0,08 %"},{"name":"50 Hz to 60 Hz","range":"100 A to 500 A","cmc":"0,05 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct and indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 40 Hz 10 µA do 200 µA CMC 2,0·10⁻⁴ · I + 15 nA\n10 Hz do 40 Hz 0,2 mA do 2 mA CMC 2,0·10⁻⁴ · I + 0,1 µA\n10 Hz do 40 Hz 2 mA do 20 mA CMC 2,0·10⁻⁴ · I + 1 µA\n10 Hz do 40 Hz 20 mA do 200 mA CMC 2,0·10⁻⁴ · I + 10 µA\n10 Hz do 45 Hz 0,2 A do 1,2 A CMC 2,0·10⁻⁴ · I + 0,14 mA\n10 Hz do 45 Hz 1,2 A do 3,1 A CMC 2,5·10⁻⁴ · I + 0,9 mA\n10 Hz do 45 Hz 3,1 A do 12 A CMC 3,5·10⁻⁴ · I + 1,1 mA\n10 Hz do 45 Hz 12 A do 30 A CMC 6,0·10⁻⁴ · I + 20 mA\n40 Hz do 1 kHz 10 µA do 220 µA CMC 1,2·10⁻⁴ · I + 10 nA\n40 Hz do 1 kHz 0,22 mA do 2,2 mA CMC 1,2·10⁻⁴ · I + 40 nA\n40 Hz do 1 kHz 2,2 mA do 22 mA CMC 1,2·10⁻⁴ · I + 0,4 µA\n40 Hz do 1 kHz 22 mA do 220 mA CMC 1,2·10⁻⁴ · I + 3 µA\n45 Hz do 1 kHz 0,22 A do 1,2 A CMC 2,0·10⁻⁴ · I + 0,07 mA\n45 Hz do 1 kHz 1,2 A do 3,1 A CMC 2,0·10⁻⁴ · I + 0,5 mA\n45 Hz do 1 kHz 3,1 A do 12 A CMC 3,0·10⁻⁴ · I + 0,8 mA\n45 Hz do 1 kHz 12 A do 30 A CMC 4,0·10⁻⁴ · I + 15 mA\n1 kHz do 5 kHz 10 µA do 120 µA CMC 2,0·10⁻⁴ · I + 13 nA\n1 kHz do 5 kHz 0,12 mA do 1,2 mA CMC 2,0·10⁻⁴ · I + 0,1 µA\n1 kHz do 5 kHz 1,2 mA do 12 mA CMC 2,0·10⁻⁴ · I + 1 µA\n1 kHz do 5 kHz 12 mA do 120 mA CMC 2,2·10⁻⁴ · I + 9 µA\n1 kHz do 5 kHz 0,12 A do 1,2 A CMC 2,2·10⁻⁴ · I + 0,1 mA\n1 kHz do 5 kHz 1,2 A do 3,1 A CMC 2,2·10⁻⁴ · I + 0,7 mA\n1 kHz do 5 kHz 3,1 A do 12 A CMC 3,3·10⁻⁴ · I + 1 mA\n1 kHz do 5 kHz 12 A do 30 A CMC 4,0·10⁻³ · I + 20 mA\n5 kHz do 10 kHz 10 µA do 200 µA CMC 5,4·10⁻⁴ · I + 25 nA\n5 kHz do 10 kHz 0,2 mA do 2 mA CMC 3,2·10⁻⁴ · I + 0,25 µA\n5 kHz do 10 kHz 2 mA do 20 mA CMC 3,2·10⁻⁴ · I + 2,5 µA\n5 kHz do 10 kHz 20 mA do 200 mA CMC 3,0·10⁻⁴ · I + 22 µA\n5 kHz do 10 kHz 0,2 A do 2 A CMC 8,0·10⁻⁴ · I + 0,25 mA\n5 kHz do 10 kHz 2 A do 3,1 A CMC 2,2·10⁻³ · I + 0,7 mA\n5 kHz do 10 kHz 3,1 A do 12 A CMC 2,2·10⁻³ · I + 1,2 mA\n10 kHz do 20 kHz 10 µA do 200 µA CMC 7,5·10⁻⁴ · I + 25 nA\n10 kHz do 20 kHz 0,2 mA do 2 mA CMC 7,5·10⁻⁴ · I + 0,25 µA\n10 kHz do 20 kHz 2 mA do 20 mA CMC 7,5·10⁻⁴ · I + 2,5 µA\n10 kHz do 20 kHz 20 mA do 200 mA CMC 7,0·10⁻⁴ · I + 23 µA\n10 kHz do 20 kHz 0,2 A do 2 A CMC 3,3·10⁻³ · I + 0,6 mA\n45 Hz do 400 Hz 10 A do 100 A CMC 0,065 %\n45 Hz do 400 Hz 100 A do 1000 A CMC 0,2 %\n400 Hz do 1 kHz 10 A do 100 A CMC 0,08 %\n50 Hz do 60 Hz 100 A do 500 A CMC 0,05 %\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/45\nLMEEiO/53","norm_bases":["LMEEiO/2","EURAMET cg-15 v. 3.0","LMEEiO/5","LMEEiO/35","LMEEiO/45","LMEEiO/53"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Multimetry\nMierniki prądu cyfrowe\nMierniki prądu analogowe\nKarty pomiarowe\nMierniki cęgowe\nTestery bezpieczeństwa elektrycznego\nMierniki parametrów sieci\nObciążenia elektroniczne\nSondy pomiarowe Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 40 Hz 10 µA do 200 µA CMC 2,0·10⁻⁴ · I + 15 nA\n10 Hz do 40 Hz 0,2 mA do 2 mA CMC 2,0·10⁻⁴ · I + 0,1 µA\n10 Hz do 40 Hz 2 mA do 20 mA CMC 2,0·10⁻⁴ · I + 1 µA\n10 Hz do 40 Hz 20 mA do 200 mA CMC 2,0·10⁻⁴ · I + 10 µA\n10 Hz do 45 Hz 0,2 A do 1,2 A CMC 2,0·10⁻⁴ · I + 0,14 mA\n10 Hz do 45 Hz 1,2 A do 3,1 A CMC 2,5·10⁻⁴ · I + 0,9 mA\n10 Hz do 45 Hz 3,1 A do 12 A CMC 3,5·10⁻⁴ · I + 1,1 mA\n10 Hz do 45 Hz 12 A do 30 A CMC 6,0·10⁻⁴ · I + 20 mA\n40 Hz do 1 kHz 10 µA do 220 µA CMC 1,2·10⁻⁴ · I + 10 nA\n40 Hz do 1 kHz 0,22 mA do 2,2 mA CMC 1,2·10⁻⁴ · I + 40 nA\n40 Hz do 1 kHz 2,2 mA do 22 mA CMC 1,2·10⁻⁴ · I + 0,4 µA\n40 Hz do 1 kHz 22 mA do 220 mA CMC 1,2·10⁻⁴ · I + 3 µA\n45 Hz do 1 kHz 0,22 A do 1,2 A CMC 2,0·10⁻⁴ · I + 0,07 mA\n45 Hz do 1 kHz 1,2 A do 3,1 A CMC 2,0·10⁻⁴ · I + 0,5 mA\n45 Hz do 1 kHz 3,1 A do 12 A CMC 3,0·10⁻⁴ · I + 0,8 mA\n45 Hz do 1 kHz 12 A do 30 A CMC 4,0·10⁻⁴ · I + 15 mA\n1 kHz do 5 kHz 10 µA do 120 µA CMC 2,0·10⁻⁴ · I + 13 nA\n1 kHz do 5 kHz 0,12 mA do 1,2 mA CMC 2,0·10⁻⁴ · I + 0,1 µA\n1 kHz do 5 kHz 1,2 mA do 12 mA CMC 2,0·10⁻⁴ · I + 1 µA\n1 kHz do 5 kHz 12 mA do 120 mA CMC 2,2·10⁻⁴ · I + 9 µA\n1 kHz do 5 kHz 0,12 A do 1,2 A CMC 2,2·10⁻⁴ · I + 0,1 mA\n1 kHz do 5 kHz 1,2 A do 3,1 A CMC 2,2·10⁻⁴ · I + 0,7 mA\n1 kHz do 5 kHz 3,1 A do 12 A CMC 3,3·10⁻⁴ · I + 1 mA\n1 kHz do 5 kHz 12 A do 30 A CMC 4,0·10⁻³ · I + 20 mA\n5 kHz do 10 kHz 10 µA do 200 µA CMC 5,4·10⁻⁴ · I + 25 nA\n5 kHz do 10 kHz 0,2 mA do 2 mA CMC 3,2·10⁻⁴ · I + 0,25 µA\n5 kHz do 10 kHz 2 mA do 20 mA CMC 3,2·10⁻⁴ · I + 2,5 µA\n5 kHz do 10 kHz 20 mA do 200 mA CMC 3,0·10⁻⁴ · I + 22 µA\n5 kHz do 10 kHz 0,2 A do 2 A CMC 8,0·10⁻⁴ · I + 0,25 mA\n5 kHz do 10 kHz 2 A do 3,1 A CMC 2,2·10⁻³ · I + 0,7 mA\n5 kHz do 10 kHz 3,1 A do 12 A CMC 2,2·10⁻³ · I + 1,2 mA\n10 kHz do 20 kHz 10 µA do 200 µA CMC 7,5·10⁻⁴ · I + 25 nA\n10 kHz do 20 kHz 0,2 mA do 2 mA CMC 7,5·10⁻⁴ · I + 0,25 µA\n10 kHz do 20 kHz 2 mA do 20 mA CMC 7,5·10⁻⁴ · I + 2,5 µA\n10 kHz do 20 kHz 20 mA do 200 mA CMC 7,0·10⁻⁴ · I + 23 µA\n10 kHz do 20 kHz 0,2 A do 2 A CMC 3,3·10⁻³ · I + 0,6 mA\n45 Hz do 400 Hz 10 A do 100 A CMC 0,065 %\n45 Hz do 400 Hz 100 A do 1000 A CMC 0,2 %\n400 Hz do 1 kHz 10 A do 100 A CMC 0,08 %\n50 Hz do 60 Hz 100 A do 500 A CMC 0,05 %\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/45\nLMEEiO/53 Multimetry\nMierniki pradu cyfrowe\nMierniki pradu analogowe\nKarty pomiarowe\nMierniki cegowe\nTestery bezpieczenstwa elektrycznego\nMierniki parametrow sieci\nObciazenia elektroniczne\nSondy pomiarowe Wzorcowanie — Prad AC\nZakres:\n10 Hz do 40 Hz 10 µA do 200 µA CMC 2,0·10⁻⁴ · I + 15 nA\n10 Hz do 40 Hz 0,2 mA do 2 mA CMC 2,0·10⁻⁴ · I + 0,1 µA\n10 Hz do 40 Hz 2 mA do 20 mA CMC 2,0·10⁻⁴ · I + 1 µA\n10 Hz do 40 Hz 20 mA do 200 mA CMC 2,0·10⁻⁴ · I + 10 µA\n10 Hz do 45 Hz 0,2 A do 1,2 A CMC 2,0·10⁻⁴ · I + 0,14 mA\n10 Hz do 45 Hz 1,2 A do 3,1 A CMC 2,5·10⁻⁴ · I + 0,9 mA\n10 Hz do 45 Hz 3,1 A do 12 A CMC 3,5·10⁻⁴ · I + 1,1 mA\n10 Hz do 45 Hz 12 A do 30 A CMC 6,0·10⁻⁴ · I + 20 mA\n40 Hz do 1 kHz 10 µA do 220 µA CMC 1,2·10⁻⁴ · I + 10 nA\n40 Hz do 1 kHz 0,22 mA do 2,2 mA CMC 1,2·10⁻⁴ · I + 40 nA\n40 Hz do 1 kHz 2,2 mA do 22 mA CMC 1,2·10⁻⁴ · I + 0,4 µA\n40 Hz do 1 kHz 22 mA do 220 mA CMC 1,2·10⁻⁴ · I + 3 µA\n45 Hz do 1 kHz 0,22 A do 1,2 A CMC 2,0·10⁻⁴ · I + 0,07 mA\n45 Hz do 1 kHz 1,2 A do 3,1 A CMC 2,0·10⁻⁴ · I + 0,5 mA\n45 Hz do 1 kHz 3,1 A do 12 A CMC 3,0·10⁻⁴ · I + 0,8 mA\n45 Hz do 1 kHz 12 A do 30 A CMC 4,0·10⁻⁴ · I + 15 mA\n1 kHz do 5 kHz 10 µA do 120 µA CMC 2,0·10⁻⁴ · I + 13 nA\n1 kHz do 5 kHz 0,12 mA do 1,2 mA CMC 2,0·10⁻⁴ · I + 0,1 µA\n1 kHz do 5 kHz 1,2 mA do 12 mA CMC 2,0·10⁻⁴ · I + 1 µA\n1 kHz do 5 kHz 12 mA do 120 mA CMC 2,2·10⁻⁴ · I + 9 µA\n1 kHz do 5 kHz 0,12 A do 1,2 A CMC 2,2·10⁻⁴ · I + 0,1 mA\n1 kHz do 5 kHz 1,2 A do 3,1 A CMC 2,2·10⁻⁴ · I + 0,7 mA\n1 kHz do 5 kHz 3,1 A do 12 A CMC 3,3·10⁻⁴ · I + 1 mA\n1 kHz do 5 kHz 12 A do 30 A CMC 4,0·10⁻³ · I + 20 mA\n5 kHz do 10 kHz 10 µA do 200 µA CMC 5,4·10⁻⁴ · I + 25 nA\n5 kHz do 10 kHz 0,2 mA do 2 mA CMC 3,2·10⁻⁴ · I + 0,25 µA\n5 kHz do 10 kHz 2 mA do 20 mA CMC 3,2·10⁻⁴ · I + 2,5 µA\n5 kHz do 10 kHz 20 mA do 200 mA CMC 3,0·10⁻⁴ · I + 22 µA\n5 kHz do 10 kHz 0,2 A do 2 A CMC 8,0·10⁻⁴ · I + 0,25 mA\n5 kHz do 10 kHz 2 A do 3,1 A CMC 2,2·10⁻³ · I + 0,7 mA\n5 kHz do 10 kHz 3,1 A do 12 A CMC 2,2·10⁻³ · I + 1,2 mA\n10 kHz do 20 kHz 10 µA do 200 µA CMC 7,5·10⁻⁴ · I + 25 nA\n10 kHz do 20 kHz 0,2 mA do 2 mA CMC 7,5·10⁻⁴ · I + 0,25 µA\n10 kHz do 20 kHz 2 mA do 20 mA CMC 7,5·10⁻⁴ · I + 2,5 µA\n10 kHz do 20 kHz 20 mA do 200 mA CMC 7,0·10⁻⁴ · I + 23 µA\n10 kHz do 20 kHz 0,2 A do 2 A CMC 3,3·10⁻³ · I + 0,6 mA\n45 Hz do 400 Hz 10 A do 100 A CMC 0,065 %\n45 Hz do 400 Hz 100 A do 1000 A CMC 0,2 %\n400 Hz do 1 kHz 10 A do 100 A CMC 0,08 %\n50 Hz do 60 Hz 100 A do 500 A CMC 0,05 %\nProcedura wewnetrzna; Metoda bezposrednia i posrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/45\nLMEEiO/53","search_en":"Multimeters Digital ammeters Analogue ammeters Data acquisition cards Clamp meters Electrical safety testers Power network parameter meters Electronic loads Measuring probes Calibration — AC current Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) AC current Internal procedure Direct and indirect method At permanent location (S) and outside of it (P) 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 45 Hz 10 Hz to 45 Hz 10 Hz to 45 Hz 10 Hz to 45 Hz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 1 kHz to 5 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 5 kHz to 10 kHz 10 kHz to 20 kHz 10 kHz to 20 kHz 10 kHz to 20 kHz 10 kHz to 20 kHz 10 kHz to 20 kHz 45 Hz to 400 Hz 45 Hz to 400 Hz 400 Hz to 1 kHz 50 Hz to 60 Hz LMEEiO/2 based on EURAMET cg-15 v. 3.0 LMEEiO/5 LMEEiO/35 LMEEiO/45 LMEEiO/53","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/2 based on EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/45\nLMEEiO/53","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"10 Hz bis 40 Hz","range":"10 µA to 200 µA","cmc":"2,0·10⁻⁴ · I + 15 nA"},{"name":"10 Hz bis 40 Hz","range":"0,2 mA to 2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"10 Hz bis 40 Hz","range":"2 mA to 20 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"10 Hz bis 40 Hz","range":"20 mA to 200 mA","cmc":"2,0·10⁻⁴ · I + 10 µA"},{"name":"10 Hz bis 45 Hz","range":"0,2 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,14 mA"},{"name":"10 Hz bis 45 Hz","range":"1,2 A to 3,1 A","cmc":"2,5·10⁻⁴ · I + 0,9 mA"},{"name":"10 Hz bis 45 Hz","range":"3,1 A to 12 A","cmc":"3,5·10⁻⁴ · I + 1,1 mA"},{"name":"10 Hz bis 45 Hz","range":"12 A to 30 A","cmc":"6,0·10⁻⁴ · I + 20 mA"},{"name":"40 Hz bis 1 kHz","range":"10 µA to 220 µA","cmc":"1,2·10⁻⁴ · I + 10 nA"},{"name":"40 Hz bis 1 kHz","range":"0,22 mA to 2,2 mA","cmc":"1,2·10⁻⁴ · I + 40 nA"},{"name":"40 Hz bis 1 kHz","range":"2,2 mA to 22 mA","cmc":"1,2·10⁻⁴ · I + 0,4 µA"},{"name":"40 Hz bis 1 kHz","range":"22 mA to 220 mA","cmc":"1,2·10⁻⁴ · I + 3 µA"},{"name":"45 Hz bis 1 kHz","range":"0,22 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,07 mA"},{"name":"45 Hz bis 1 kHz","range":"1,2 A to 3,1 A","cmc":"2,0·10⁻⁴ · I + 0,5 mA"},{"name":"45 Hz bis 1 kHz","range":"3,1 A to 12 A","cmc":"3,0·10⁻⁴ · I + 0,8 mA"},{"name":"45 Hz bis 1 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻⁴ · I + 15 mA"},{"name":"1 kHz bis 5 kHz","range":"10 µA to 120 µA","cmc":"2,0·10⁻⁴ · I + 13 nA"},{"name":"1 kHz bis 5 kHz","range":"0,12 mA to 1,2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"1 kHz bis 5 kHz","range":"1,2 mA to 12 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"1 kHz bis 5 kHz","range":"12 mA to 120 mA","cmc":"2,2·10⁻⁴ · I + 9 µA"},{"name":"1 kHz bis 5 kHz","range":"0,12 A to 1,2 A","cmc":"2,2·10⁻⁴ · I + 0,1 mA"},{"name":"1 kHz bis 5 kHz","range":"1,2 A to 3,1 A","cmc":"2,2·10⁻⁴ · I + 0,7 mA"},{"name":"1 kHz bis 5 kHz","range":"3,1 A to 12 A","cmc":"3,3·10⁻⁴ · I + 1 mA"},{"name":"1 kHz bis 5 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻³ · I + 20 mA"},{"name":"5 kHz bis 10 kHz","range":"10 µA to 200 µA","cmc":"5,4·10⁻⁴ · I + 25 nA"},{"name":"5 kHz bis 10 kHz","range":"0,2 mA to 2 mA","cmc":"3,2·10⁻⁴ · I + 0,25 µA"},{"name":"5 kHz bis 10 kHz","range":"2 mA to 20 mA","cmc":"3,2·10⁻⁴ · I + 2,5 µA"},{"name":"5 kHz bis 10 kHz","range":"20 mA to 200 mA","cmc":"3,0·10⁻⁴ · I + 22 µA"},{"name":"5 kHz bis 10 kHz","range":"0,2 A to 2 A","cmc":"8,0·10⁻⁴ · I + 0,25 mA"},{"name":"5 kHz bis 10 kHz","range":"2 A to 3,1 A","cmc":"2,2·10⁻³ · I + 0,7 mA"},{"name":"5 kHz bis 10 kHz","range":"3,1 A to 12 A","cmc":"2,2·10⁻³ · I + 1,2 mA"},{"name":"10 kHz bis 20 kHz","range":"10 µA to 200 µA","cmc":"7,5·10⁻⁴ · I + 25 nA"},{"name":"10 kHz bis 20 kHz","range":"0,2 mA to 2 mA","cmc":"7,5·10⁻⁴ · I + 0,25 µA"},{"name":"10 kHz bis 20 kHz","range":"2 mA to 20 mA","cmc":"7,5·10⁻⁴ · I + 2,5 µA"},{"name":"10 kHz bis 20 kHz","range":"20 mA to 200 mA","cmc":"7,0·10⁻⁴ · I + 23 µA"},{"name":"10 kHz bis 20 kHz","range":"0,2 A to 2 A","cmc":"3,3·10⁻³ · I + 0,6 mA"},{"name":"45 Hz bis 400 Hz","range":"10 A to 100 A","cmc":"0,065 %"},{"name":"45 Hz bis 400 Hz","range":"100 A to 1000 A","cmc":"0,2 %"},{"name":"400 Hz bis 1 kHz","range":"10 A to 100 A","cmc":"0,08 %"},{"name":"50 Hz bis 60 Hz","range":"100 A to 500 A","cmc":"0,05 %"}],"reference_de":"LMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/45\nLMEEiO/53","regulatory_area_de":"AC-Strom","search_de":"Multimeter Digitale Strommessgeräte Analoge Strommessgeräte Messkarten Zangenmessgeräte Prüfgeräte für elektrische Sicherheit Netzparametermessgeräte Elektronische Lasten Messsonden Kalibrierung — Wechselstrom Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Strom Internes Verfahren Direktes und indirektes Verfahren Am festen Standort (S) und außerhalb (P) 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 45 Hz 10 Hz bis 45 Hz 10 Hz bis 45 Hz 10 Hz bis 45 Hz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 45 Hz bis 1 kHz 45 Hz bis 1 kHz 45 Hz bis 1 kHz 45 Hz bis 1 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 1 kHz bis 5 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 5 kHz bis 10 kHz 10 kHz bis 20 kHz 10 kHz bis 20 kHz 10 kHz bis 20 kHz 10 kHz bis 20 kHz 10 kHz bis 20 kHz 45 Hz bis 400 Hz 45 Hz bis 400 Hz 400 Hz bis 1 kHz 50 Hz bis 60 Hz LMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0 LMEEiO/5 LMEEiO/35 LMEEiO/45 LMEEiO/53","technique_de":"Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes und indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Multimeter\nDigitale Strommessgeräte\nAnaloge Strommessgeräte\nMesskarten\nZangenmessgeräte\nPrüfgeräte für elektrische Sicherheit\nNetzparametermessgeräte\nElektronische Lasten\nMesssonden","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"10 µA to 200 µA","cmc":"2,0·10⁻⁴ · I + 15 nA"},{"name":"10 Hz 至 40 Hz","range":"0,2 mA to 2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"10 Hz 至 40 Hz","range":"2 mA to 20 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"10 Hz 至 40 Hz","range":"20 mA to 200 mA","cmc":"2,0·10⁻⁴ · I + 10 µA"},{"name":"10 Hz 至 45 Hz","range":"0,2 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,14 mA"},{"name":"10 Hz 至 45 Hz","range":"1,2 A to 3,1 A","cmc":"2,5·10⁻⁴ · I + 0,9 mA"},{"name":"10 Hz 至 45 Hz","range":"3,1 A to 12 A","cmc":"3,5·10⁻⁴ · I + 1,1 mA"},{"name":"10 Hz 至 45 Hz","range":"12 A to 30 A","cmc":"6,0·10⁻⁴ · I + 20 mA"},{"name":"40 Hz 至 1 kHz","range":"10 µA to 220 µA","cmc":"1,2·10⁻⁴ · I + 10 nA"},{"name":"40 Hz 至 1 kHz","range":"0,22 mA to 2,2 mA","cmc":"1,2·10⁻⁴ · I + 40 nA"},{"name":"40 Hz 至 1 kHz","range":"2,2 mA to 22 mA","cmc":"1,2·10⁻⁴ · I + 0,4 µA"},{"name":"40 Hz 至 1 kHz","range":"22 mA to 220 mA","cmc":"1,2·10⁻⁴ · I + 3 µA"},{"name":"45 Hz 至 1 kHz","range":"0,22 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,07 mA"},{"name":"45 Hz 至 1 kHz","range":"1,2 A to 3,1 A","cmc":"2,0·10⁻⁴ · I + 0,5 mA"},{"name":"45 Hz 至 1 kHz","range":"3,1 A to 12 A","cmc":"3,0·10⁻⁴ · I + 0,8 mA"},{"name":"45 Hz 至 1 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻⁴ · I + 15 mA"},{"name":"1 kHz 至 5 kHz","range":"10 µA to 120 µA","cmc":"2,0·10⁻⁴ · I + 13 nA"},{"name":"1 kHz 至 5 kHz","range":"0,12 mA to 1,2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"1 kHz 至 5 kHz","range":"1,2 mA to 12 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"1 kHz 至 5 kHz","range":"12 mA to 120 mA","cmc":"2,2·10⁻⁴ · I + 9 µA"},{"name":"1 kHz 至 5 kHz","range":"0,12 A to 1,2 A","cmc":"2,2·10⁻⁴ · I + 0,1 mA"},{"name":"1 kHz 至 5 kHz","range":"1,2 A to 3,1 A","cmc":"2,2·10⁻⁴ · I + 0,7 mA"},{"name":"1 kHz 至 5 kHz","range":"3,1 A to 12 A","cmc":"3,3·10⁻⁴ · I + 1 mA"},{"name":"1 kHz 至 5 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻³ · I + 20 mA"},{"name":"5 kHz 至 10 kHz","range":"10 µA to 200 µA","cmc":"5,4·10⁻⁴ · I + 25 nA"},{"name":"5 kHz 至 10 kHz","range":"0,2 mA to 2 mA","cmc":"3,2·10⁻⁴ · I + 0,25 µA"},{"name":"5 kHz 至 10 kHz","range":"2 mA to 20 mA","cmc":"3,2·10⁻⁴ · I + 2,5 µA"},{"name":"5 kHz 至 10 kHz","range":"20 mA to 200 mA","cmc":"3,0·10⁻⁴ · I + 22 µA"},{"name":"5 kHz 至 10 kHz","range":"0,2 A to 2 A","cmc":"8,0·10⁻⁴ · I + 0,25 mA"},{"name":"5 kHz 至 10 kHz","range":"2 A to 3,1 A","cmc":"2,2·10⁻³ · I + 0,7 mA"},{"name":"5 kHz 至 10 kHz","range":"3,1 A to 12 A","cmc":"2,2·10⁻³ · I + 1,2 mA"},{"name":"10 kHz 至 20 kHz","range":"10 µA to 200 µA","cmc":"7,5·10⁻⁴ · I + 25 nA"},{"name":"10 kHz 至 20 kHz","range":"0,2 mA to 2 mA","cmc":"7,5·10⁻⁴ · I + 0,25 µA"},{"name":"10 kHz 至 20 kHz","range":"2 mA to 20 mA","cmc":"7,5·10⁻⁴ · I + 2,5 µA"},{"name":"10 kHz 至 20 kHz","range":"20 mA to 200 mA","cmc":"7,0·10⁻⁴ · I + 23 µA"},{"name":"10 kHz 至 20 kHz","range":"0,2 A to 2 A","cmc":"3,3·10⁻³ · I + 0,6 mA"},{"name":"45 Hz 至 400 Hz","range":"10 A to 100 A","cmc":"0,065 %"},{"name":"45 Hz 至 400 Hz","range":"100 A to 1000 A","cmc":"0,2 %"},{"name":"400 Hz 至 1 kHz","range":"10 A to 100 A","cmc":"0,08 %"},{"name":"50 Hz 至 60 Hz","range":"100 A to 500 A","cmc":"0,05 %"}],"reference_zh":"LMEEiO/2 依据EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/45\nLMEEiO/53","regulatory_area_zh":"交流电流","search_zh":"万用表 数字电流表 模拟电流表 测量卡 钳形表 电气安全测试仪 电网参数测量仪 电子负载 测量探头 校准 — 交流电流 内部程序；直接法和间接法；在固定地点 (S) 及固定地点以外 (P) 交流电流 内部程序 直接法和间接法 在固定地点 (S) 及固定地点以外 (P) 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 45 Hz 10 Hz 至 45 Hz 10 Hz 至 45 Hz 10 Hz 至 45 Hz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 45 Hz 至 1 kHz 45 Hz 至 1 kHz 45 Hz 至 1 kHz 45 Hz 至 1 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 1 kHz 至 5 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 5 kHz 至 10 kHz 10 kHz 至 20 kHz 10 kHz 至 20 kHz 10 kHz 至 20 kHz 10 kHz 至 20 kHz 10 kHz 至 20 kHz 45 Hz 至 400 Hz 45 Hz 至 400 Hz 400 Hz 至 1 kHz 50 Hz 至 60 Hz LMEEiO/2 依据EURAMET cg-15 v. 3.0 LMEEiO/5 LMEEiO/35 LMEEiO/45 LMEEiO/53","technique_zh":"内部程序；直接法和间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法和间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"万用表\n数字电流表\n模拟电流表\n测量卡\n钳形表\n电气安全测试仪\n电网参数测量仪\n电子负载\n测量探头","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"10 Hz až 40 Hz","range":"10 µA to 200 µA","cmc":"2,0·10⁻⁴ · I + 15 nA"},{"name":"10 Hz až 40 Hz","range":"0,2 mA to 2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"10 Hz až 40 Hz","range":"2 mA to 20 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"10 Hz až 40 Hz","range":"20 mA to 200 mA","cmc":"2,0·10⁻⁴ · I + 10 µA"},{"name":"10 Hz až 45 Hz","range":"0,2 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,14 mA"},{"name":"10 Hz až 45 Hz","range":"1,2 A to 3,1 A","cmc":"2,5·10⁻⁴ · I + 0,9 mA"},{"name":"10 Hz až 45 Hz","range":"3,1 A to 12 A","cmc":"3,5·10⁻⁴ · I + 1,1 mA"},{"name":"10 Hz až 45 Hz","range":"12 A to 30 A","cmc":"6,0·10⁻⁴ · I + 20 mA"},{"name":"40 Hz až 1 kHz","range":"10 µA to 220 µA","cmc":"1,2·10⁻⁴ · I + 10 nA"},{"name":"40 Hz až 1 kHz","range":"0,22 mA to 2,2 mA","cmc":"1,2·10⁻⁴ · I + 40 nA"},{"name":"40 Hz až 1 kHz","range":"2,2 mA to 22 mA","cmc":"1,2·10⁻⁴ · I + 0,4 µA"},{"name":"40 Hz až 1 kHz","range":"22 mA to 220 mA","cmc":"1,2·10⁻⁴ · I + 3 µA"},{"name":"45 Hz až 1 kHz","range":"0,22 A to 1,2 A","cmc":"2,0·10⁻⁴ · I + 0,07 mA"},{"name":"45 Hz až 1 kHz","range":"1,2 A to 3,1 A","cmc":"2,0·10⁻⁴ · I + 0,5 mA"},{"name":"45 Hz až 1 kHz","range":"3,1 A to 12 A","cmc":"3,0·10⁻⁴ · I + 0,8 mA"},{"name":"45 Hz až 1 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻⁴ · I + 15 mA"},{"name":"1 kHz až 5 kHz","range":"10 µA to 120 µA","cmc":"2,0·10⁻⁴ · I + 13 nA"},{"name":"1 kHz až 5 kHz","range":"0,12 mA to 1,2 mA","cmc":"2,0·10⁻⁴ · I + 0,1 µA"},{"name":"1 kHz až 5 kHz","range":"1,2 mA to 12 mA","cmc":"2,0·10⁻⁴ · I + 1 µA"},{"name":"1 kHz až 5 kHz","range":"12 mA to 120 mA","cmc":"2,2·10⁻⁴ · I + 9 µA"},{"name":"1 kHz až 5 kHz","range":"0,12 A to 1,2 A","cmc":"2,2·10⁻⁴ · I + 0,1 mA"},{"name":"1 kHz až 5 kHz","range":"1,2 A to 3,1 A","cmc":"2,2·10⁻⁴ · I + 0,7 mA"},{"name":"1 kHz až 5 kHz","range":"3,1 A to 12 A","cmc":"3,3·10⁻⁴ · I + 1 mA"},{"name":"1 kHz až 5 kHz","range":"12 A to 30 A","cmc":"4,0·10⁻³ · I + 20 mA"},{"name":"5 kHz až 10 kHz","range":"10 µA to 200 µA","cmc":"5,4·10⁻⁴ · I + 25 nA"},{"name":"5 kHz až 10 kHz","range":"0,2 mA to 2 mA","cmc":"3,2·10⁻⁴ · I + 0,25 µA"},{"name":"5 kHz až 10 kHz","range":"2 mA to 20 mA","cmc":"3,2·10⁻⁴ · I + 2,5 µA"},{"name":"5 kHz až 10 kHz","range":"20 mA to 200 mA","cmc":"3,0·10⁻⁴ · I + 22 µA"},{"name":"5 kHz až 10 kHz","range":"0,2 A to 2 A","cmc":"8,0·10⁻⁴ · I + 0,25 mA"},{"name":"5 kHz až 10 kHz","range":"2 A to 3,1 A","cmc":"2,2·10⁻³ · I + 0,7 mA"},{"name":"5 kHz až 10 kHz","range":"3,1 A to 12 A","cmc":"2,2·10⁻³ · I + 1,2 mA"},{"name":"10 kHz až 20 kHz","range":"10 µA to 200 µA","cmc":"7,5·10⁻⁴ · I + 25 nA"},{"name":"10 kHz až 20 kHz","range":"0,2 mA to 2 mA","cmc":"7,5·10⁻⁴ · I + 0,25 µA"},{"name":"10 kHz až 20 kHz","range":"2 mA to 20 mA","cmc":"7,5·10⁻⁴ · I + 2,5 µA"},{"name":"10 kHz až 20 kHz","range":"20 mA to 200 mA","cmc":"7,0·10⁻⁴ · I + 23 µA"},{"name":"10 kHz až 20 kHz","range":"0,2 A to 2 A","cmc":"3,3·10⁻³ · I + 0,6 mA"},{"name":"45 Hz až 400 Hz","range":"10 A to 100 A","cmc":"0,065 %"},{"name":"45 Hz až 400 Hz","range":"100 A to 1000 A","cmc":"0,2 %"},{"name":"400 Hz až 1 kHz","range":"10 A to 100 A","cmc":"0,08 %"},{"name":"50 Hz až 60 Hz","range":"100 A to 500 A","cmc":"0,05 %"}],"reference_cs":"LMEEiO/2 na základě EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/45\nLMEEiO/53","regulatory_area_cs":"Proud AC","search_cs":"Multimetry Digitální měřiče proudu Analogové měřiče proudu Měřicí karty Klešťové měřiče Testery elektrické bezpečnosti Měřiče parametrů sítě Elektronické zátěže Měřicí sondy Kalibrace — Proud AC Vnitřní postup; Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P) Proud AC Vnitřní postup Přímá a nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 45 Hz 10 Hz až 45 Hz 10 Hz až 45 Hz 10 Hz až 45 Hz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 45 Hz až 1 kHz 45 Hz až 1 kHz 45 Hz až 1 kHz 45 Hz až 1 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 1 kHz až 5 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 5 kHz až 10 kHz 10 kHz až 20 kHz 10 kHz až 20 kHz 10 kHz až 20 kHz 10 kHz až 20 kHz 10 kHz až 20 kHz 45 Hz až 400 Hz 45 Hz až 400 Hz 400 Hz až 1 kHz 50 Hz až 60 Hz LMEEiO/2 na základě EURAMET cg-15 v. 3.0 LMEEiO/5 LMEEiO/35 LMEEiO/45 LMEEiO/53","technique_cs":"Vnitřní postup; Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá a nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Multimetry\nDigitální měřiče proudu\nAnalogové měřiče proudu\nMěřicí karty\nKlešťové měřiče\nTestery elektrické bezpečnosti\nMěřiče parametrů sítě\nElektronické zátěže\nMěřicí sondy"},{"_id":"375450c2bf8ac9241ea021ea","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Testery wyłączników RCD","test_object_en":"RCD testers","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"50 Hz","range":"3 mA do 3000 mA","cmc":"1 %"}],"parameters_en":[{"name":"50 Hz","range":"3 mA to 3000 mA","cmc":"1 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\n50 Hz 3 mA do 3000 mA CMC 1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/35","norm_bases":["LMEEiO/35"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Testery wyłączników RCD Wzorcowanie — Prąd AC\n50 Hz 3 mA do 3000 mA CMC 1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/35 Testery wylacznikow RCD Wzorcowanie — Prad AC\n50 Hz 3 mA do 3000 mA CMC 1 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/35","search_en":"RCD testers Calibration — AC current Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC current Internal procedure Direct method At permanent location (S) and outside of it (P) 50 Hz LMEEiO/35","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"50 Hz","range":"3 mA to 3000 mA","cmc":"1 %"}],"regulatory_area_de":"AC-Strom","search_de":"RCD-Prüfgeräte Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 50 Hz LMEEiO/35","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"RCD-Prüfgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"50 Hz","range":"3 mA to 3000 mA","cmc":"1 %"}],"regulatory_area_zh":"交流电流","search_zh":"RCD 测试仪 校准 — 交流电流 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电流 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 50 Hz LMEEiO/35","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"RCD 测试仪","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"50 Hz","range":"3 mA to 3000 mA","cmc":"1 %"}],"regulatory_area_cs":"Proud AC","search_cs":"Testery proudových chráničů RCD Kalibrace — Proud AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Proud AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 Hz LMEEiO/35","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Testery proudových chráničů RCD"},{"_id":"a5e8f2755a1d553f8cea486b","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki prądu upływu","test_object_en":"Leakage current meters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"50 Hz","range":"15 µA do 4 mA","cmc":"0,1 %"},{"name":"50 Hz","range":"4 mA do 1000 mA","cmc":"0,03 %"}],"parameters_en":[{"name":"50 Hz","range":"15 µA to 4 mA","cmc":"0,1 %"},{"name":"50 Hz","range":"4 mA to 1000 mA","cmc":"0,03 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n50 Hz 15 µA do 4 mA CMC 0,1 %\n50 Hz 4 mA do 1000 mA CMC 0,03 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/35","norm_bases":["LMEEiO/35"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki prądu upływu Wzorcowanie — Prąd AC\nZakres:\n50 Hz 15 µA do 4 mA CMC 0,1 %\n50 Hz 4 mA do 1000 mA CMC 0,03 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/35 Mierniki pradu uplywu Wzorcowanie — Prad AC\nZakres:\n50 Hz 15 µA do 4 mA CMC 0,1 %\n50 Hz 4 mA do 1000 mA CMC 0,03 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/35","search_en":"Leakage current meters Calibration — AC current Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC current Internal procedure Direct method At permanent location (S) and outside of it (P) 50 Hz 50 Hz LMEEiO/35","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"50 Hz","range":"15 µA to 4 mA","cmc":"0,1 %"},{"name":"50 Hz","range":"4 mA to 1000 mA","cmc":"0,03 %"}],"regulatory_area_de":"AC-Strom","search_de":"Ableitstrommessgeräte Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 50 Hz 50 Hz LMEEiO/35","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Ableitstrommessgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"50 Hz","range":"15 µA to 4 mA","cmc":"0,1 %"},{"name":"50 Hz","range":"4 mA to 1000 mA","cmc":"0,03 %"}],"regulatory_area_zh":"交流电流","search_zh":"泄漏电流表 校准 — 交流电流 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电流 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 50 Hz 50 Hz LMEEiO/35","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"泄漏电流表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"50 Hz","range":"15 µA to 4 mA","cmc":"0,1 %"},{"name":"50 Hz","range":"4 mA to 1000 mA","cmc":"0,03 %"}],"regulatory_area_cs":"Proud AC","search_cs":"Měřiče unikajícího proudu Kalibrace — Proud AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Proud AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 Hz 50 Hz LMEEiO/35","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče unikajícího proudu"},{"_id":"e5d3034ae84eb01d79bd6608","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory jakości energii\n- współczynnik THD I","test_object_en":"Power quality analysers\n- THD I factor","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"50 Hz","range":"0% do 540 %","cmc":"0,1 %"}],"parameters_en":[{"name":"50 Hz","range":"0% to 540 %","cmc":"0,1 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\n50 Hz 0% do 540 % CMC 0,1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/50","norm_bases":["LMEEiO/50"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Analizatory jakości energii\n- współczynnik THD I Wzorcowanie — Prąd AC\n50 Hz 0% do 540 % CMC 0,1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/50 Analizatory jakosci energii\n- wspolczynnik THD I Wzorcowanie — Prad AC\n50 Hz 0% do 540 % CMC 0,1 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/50","search_en":"Power quality analysers - THD I factor Calibration — AC current Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC current Internal procedure Direct method At permanent location (S) and outside of it (P) 50 Hz LMEEiO/50","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"50 Hz","range":"0% to 540 %","cmc":"0,1 %"}],"regulatory_area_de":"AC-Strom","search_de":"Netzqualitätsanalysatoren - THD-I-Faktor Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 50 Hz LMEEiO/50","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Netzqualitätsanalysatoren\n- THD-I-Faktor","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"50 Hz","range":"0% to 540 %","cmc":"0,1 %"}],"regulatory_area_zh":"交流电流","search_zh":"电能质量分析仪 - 电流总谐波畸变率 THD I 校准 — 交流电流 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电流 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 50 Hz LMEEiO/50","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电能质量分析仪\n- 电流总谐波畸变率 THD I","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"50 Hz","range":"0% to 540 %","cmc":"0,1 %"}],"regulatory_area_cs":"Proud AC","search_cs":"Analyzátory kvality elektrické energie - činitel THD I Kalibrace — Proud AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Proud AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 Hz LMEEiO/50","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analyzátory kvality elektrické energie\n- činitel THD I"},{"_id":"9b4edea9d2fbc7bdb058355f","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory jakości energii\n- wyższe harmoniczne prądu","test_object_en":"Power quality analysers\n- current harmonics","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"50 Hz; do 31 harmonicznej","range":"0 A do 20 A","cmc":"0,1 %"}],"parameters_en":[{"name":"50 Hz; up to the 31st harmonic","range":"0 A to 20 A","cmc":"0,1 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\n50 Hz; do 31 harmonicznej 0 A do 20 A CMC 0,1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/50","norm_bases":["LMEEiO/50"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Analizatory jakości energii\n- wyższe harmoniczne prądu Wzorcowanie — Prąd AC\n50 Hz; do 31 harmonicznej 0 A do 20 A CMC 0,1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/50 Analizatory jakosci energii\n- wyzsze harmoniczne pradu Wzorcowanie — Prad AC\n50 Hz; do 31 harmonicznej 0 A do 20 A CMC 0,1 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/50","search_en":"Power quality analysers - current harmonics Calibration — AC current Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC current Internal procedure Direct method At permanent location (S) and outside of it (P) 50 Hz; up to the 31st harmonic LMEEiO/50","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"50 Hz; bis zur 31. Harmonischen","range":"0 A to 20 A","cmc":"0,1 %"}],"regulatory_area_de":"AC-Strom","search_de":"Netzqualitätsanalysatoren - Stromoberschwingungen Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 50 Hz; bis zur 31. Harmonischen LMEEiO/50","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Netzqualitätsanalysatoren\n- Stromoberschwingungen","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"50 Hz; 至 31 次谐波","range":"0 A to 20 A","cmc":"0,1 %"}],"regulatory_area_zh":"交流电流","search_zh":"电能质量分析仪 - 电流谐波 校准 — 交流电流 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电流 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 50 Hz; 至 31 次谐波 LMEEiO/50","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电能质量分析仪\n- 电流谐波","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"50 Hz; do 31. harmonické","range":"0 A to 20 A","cmc":"0,1 %"}],"regulatory_area_cs":"Proud AC","search_cs":"Analyzátory kvality elektrické energie - vyšší harmonické proudu Kalibrace — Proud AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Proud AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 Hz; do 31. harmonické LMEEiO/50","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analyzátory kvality elektrické energie\n- vyšší harmonické proudu"},{"_id":"a9cded665705e993451eadce","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory jakości energii\n- prąd w warunkach asymetrii zasilania","test_object_en":"Power quality analysers\n- current under supply asymmetry conditions","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"50 Hz; 15%","range":"0 V do 400 V","cmc":"0,05%"}],"parameters_en":[{"name":"50 Hz; 15%","range":"0 V to 400 V","cmc":"0,05%"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\n50 Hz; 15% 0 V do 400 V CMC 0,05%\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/50","norm_bases":["LMEEiO/50"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Analizatory jakości energii\n- prąd w warunkach asymetrii zasilania Wzorcowanie — Prąd AC\n50 Hz; 15% 0 V do 400 V CMC 0,05%\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/50 Analizatory jakosci energii\n- prad w warunkach asymetrii zasilania Wzorcowanie — Prad AC\n50 Hz; 15% 0 V do 400 V CMC 0,05%\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/50","search_en":"Power quality analysers - current under supply asymmetry conditions Calibration — AC current Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC current Internal procedure Direct method At permanent location (S) and outside of it (P) 50 Hz; 15% LMEEiO/50","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"50 Hz; 15%","range":"0 V to 400 V","cmc":"0,05%"}],"regulatory_area_de":"AC-Strom","search_de":"Netzqualitätsanalysatoren - Strom bei unsymmetrischer Versorgung Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 50 Hz; 15% LMEEiO/50","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Netzqualitätsanalysatoren\n- Strom bei unsymmetrischer Versorgung","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"50 Hz; 15%","range":"0 V to 400 V","cmc":"0,05%"}],"regulatory_area_zh":"交流电流","search_zh":"电能质量分析仪 - 供电不对称条件下的电流 校准 — 交流电流 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电流 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 50 Hz; 15% LMEEiO/50","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电能质量分析仪\n- 供电不对称条件下的电流","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"50 Hz; 15%","range":"0 V to 400 V","cmc":"0,05%"}],"regulatory_area_cs":"Proud AC","search_cs":"Analyzátory kvality elektrické energie - proud při nesymetrii napájení Kalibrace — Proud AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Proud AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 Hz; 15% LMEEiO/50","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analyzátory kvality elektrické energie\n- proud při nesymetrii napájení"},{"_id":"6e8e8bfeb4f8f2b59061a8c8","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Rezystory stałe\nRezystory regulowane\nKalibratory\nOscyloskopy\nBoczniki\nKarty pomiarowe","test_object_en":"Fixed resistors\nVariable resistors\nCalibrators\nOscilloscopes\nShunts\nData acquisition cards","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0 Ω do 0,0001 Ω","cmc":"2,0·10⁻⁴ · R + 0,02 µΩ"},{"name":"","range":"0,0001 Ω","cmc":"0,002 %"},{"name":"","range":"0,001 Ω","cmc":"0,0005 %"},{"name":"","range":"0,001 Ω do 0,01 Ω","cmc":"1,0·10⁻⁵ · R + 0,02 µΩ"},{"name":"","range":"0,01 Ω do 200 kΩ","cmc":"0,0002 %"},{"name":"","range":"200 kΩ do 2 MΩ","cmc":"1,0·10⁻⁵ · R + 1,2 Ω"},{"name":"","range":"1 MΩ","cmc":"0,0004 %"},{"name":"","range":"2 MΩ do 20 MΩ","cmc":"1,7·10⁻⁵ · R + 15 Ω"},{"name":"","range":"20 MΩ do 200 MΩ","cmc":"7,0·10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"200 MΩ do 1 GΩ","cmc":"1,7·10⁻⁴ · R + 120 kΩ"},{"name":"","range":"1 GΩ do 10 GΩ","cmc":"0,04 %"},{"name":"","range":"10 GΩ do 100 GΩ","cmc":"0,1 %"},{"name":"","range":"100 GΩ do 1 TΩ","cmc":"0,4 %"}],"parameters_en":[{"name":"","range":"0 Ω to 0,0001 Ω","cmc":"2,0·10⁻⁴ · R + 0,02 µΩ"},{"name":"","range":"0,0001 Ω","cmc":"0,002 %"},{"name":"","range":"0,001 Ω","cmc":"0,0005 %"},{"name":"","range":"0,001 Ω to 0,01 Ω","cmc":"1,0·10⁻⁵ · R + 0,02 µΩ"},{"name":"","range":"0,01 Ω to 200 kΩ","cmc":"0,0002 %"},{"name":"","range":"200 kΩ to 2 MΩ","cmc":"1,0·10⁻⁵ · R + 1,2 Ω"},{"name":"","range":"1 MΩ","cmc":"0,0004 %"},{"name":"","range":"2 MΩ to 20 MΩ","cmc":"1,7·10⁻⁵ · R + 15 Ω"},{"name":"","range":"20 MΩ to 200 MΩ","cmc":"7,0·10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"200 MΩ to 1 GΩ","cmc":"1,7·10⁻⁴ · R + 120 kΩ"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,04 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,1 %"},{"name":"","range":"100 GΩ to 1 TΩ","cmc":"0,4 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct and indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0 Ω do 0,0001 Ω CMC 2,0·10⁻⁴ · R + 0,02 µΩ\n0,0001 Ω CMC 0,002 %\n0,001 Ω CMC 0,0005 %\n0,001 Ω do 0,01 Ω CMC 1,0·10⁻⁵ · R + 0,02 µΩ\n0,01 Ω do 200 kΩ CMC 0,0002 %\n200 kΩ do 2 MΩ CMC 1,0·10⁻⁵ · R + 1,2 Ω\n1 MΩ CMC 0,0004 %\n2 MΩ do 20 MΩ CMC 1,7·10⁻⁵ · R + 15 Ω\n20 MΩ do 200 MΩ CMC 7,0·10⁻⁵ · R + 1,2 kΩ\n200 MΩ do 1 GΩ CMC 1,7·10⁻⁴ · R + 120 kΩ\n1 GΩ do 10 GΩ CMC 0,04 %\n10 GΩ do 100 GΩ CMC 0,1 %\n100 GΩ do 1 TΩ CMC 0,4 %\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/3\nLMEEiO/4\nLMEEiO/13\nLMEEiO/45","norm_bases":["LMEEiO/3","LMEEiO/4","LMEEiO/13","LMEEiO/45"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"S, P","note":"R – wielkość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Rezystory stałe\nRezystory regulowane\nKalibratory\nOscyloskopy\nBoczniki\nKarty pomiarowe Wzorcowanie — Rezystancja DC\nZakres:\n0 Ω do 0,0001 Ω CMC 2,0·10⁻⁴ · R + 0,02 µΩ\n0,0001 Ω CMC 0,002 %\n0,001 Ω CMC 0,0005 %\n0,001 Ω do 0,01 Ω CMC 1,0·10⁻⁵ · R + 0,02 µΩ\n0,01 Ω do 200 kΩ CMC 0,0002 %\n200 kΩ do 2 MΩ CMC 1,0·10⁻⁵ · R + 1,2 Ω\n1 MΩ CMC 0,0004 %\n2 MΩ do 20 MΩ CMC 1,7·10⁻⁵ · R + 15 Ω\n20 MΩ do 200 MΩ CMC 7,0·10⁻⁵ · R + 1,2 kΩ\n200 MΩ do 1 GΩ CMC 1,7·10⁻⁴ · R + 120 kΩ\n1 GΩ do 10 GΩ CMC 0,04 %\n10 GΩ do 100 GΩ CMC 0,1 %\n100 GΩ do 1 TΩ CMC 0,4 %\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/3\nLMEEiO/4\nLMEEiO/13\nLMEEiO/45 Rezystory stale\nRezystory regulowane\nKalibratory\nOscyloskopy\nBoczniki\nKarty pomiarowe Wzorcowanie — Rezystancja DC\nZakres:\n0 Ω do 0,0001 Ω CMC 2,0·10⁻⁴ · R + 0,02 µΩ\n0,0001 Ω CMC 0,002 %\n0,001 Ω CMC 0,0005 %\n0,001 Ω do 0,01 Ω CMC 1,0·10⁻⁵ · R + 0,02 µΩ\n0,01 Ω do 200 kΩ CMC 0,0002 %\n200 kΩ do 2 MΩ CMC 1,0·10⁻⁵ · R + 1,2 Ω\n1 MΩ CMC 0,0004 %\n2 MΩ do 20 MΩ CMC 1,7·10⁻⁵ · R + 15 Ω\n20 MΩ do 200 MΩ CMC 7,0·10⁻⁵ · R + 1,2 kΩ\n200 MΩ do 1 GΩ CMC 1,7·10⁻⁴ · R + 120 kΩ\n1 GΩ do 10 GΩ CMC 0,04 %\n10 GΩ do 100 GΩ CMC 0,1 %\n100 GΩ do 1 TΩ CMC 0,4 %\nProcedura wewnetrzna; Metoda bezposrednia i posrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/3\nLMEEiO/4\nLMEEiO/13\nLMEEiO/45","search_en":"Fixed resistors Variable resistors Calibrators Oscilloscopes Shunts Data acquisition cards Calibration — DC resistance Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) DC resistance Internal procedure Direct and indirect method At permanent location (S) and outside of it (P) LMEEiO/3 LMEEiO/4 LMEEiO/13 LMEEiO/45","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":19,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0 Ω to 0,0001 Ω","cmc":"2,0·10⁻⁴ · R + 0,02 µΩ"},{"name":"","range":"0,0001 Ω","cmc":"0,002 %"},{"name":"","range":"0,001 Ω","cmc":"0,0005 %"},{"name":"","range":"0,001 Ω to 0,01 Ω","cmc":"1,0·10⁻⁵ · R + 0,02 µΩ"},{"name":"","range":"0,01 Ω to 200 kΩ","cmc":"0,0002 %"},{"name":"","range":"200 kΩ to 2 MΩ","cmc":"1,0·10⁻⁵ · R + 1,2 Ω"},{"name":"","range":"1 MΩ","cmc":"0,0004 %"},{"name":"","range":"2 MΩ to 20 MΩ","cmc":"1,7·10⁻⁵ · R + 15 Ω"},{"name":"","range":"20 MΩ to 200 MΩ","cmc":"7,0·10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"200 MΩ to 1 GΩ","cmc":"1,7·10⁻⁴ · R + 120 kΩ"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,04 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,1 %"},{"name":"","range":"100 GΩ to 1 TΩ","cmc":"0,4 %"}],"regulatory_area_de":"DC-Widerstand","search_de":"Festwiderstände Einstellbare Widerstände Kalibratoren Oszilloskope Shunts Messkarten Kalibrierung — DC-Widerstand Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Widerstand Internes Verfahren Direktes und indirektes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/3 LMEEiO/4 LMEEiO/13 LMEEiO/45","technique_de":"Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes und indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Festwiderstände\nEinstellbare Widerstände\nKalibratoren\nOszilloskope\nShunts\nMesskarten","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0 Ω to 0,0001 Ω","cmc":"2,0·10⁻⁴ · R + 0,02 µΩ"},{"name":"","range":"0,0001 Ω","cmc":"0,002 %"},{"name":"","range":"0,001 Ω","cmc":"0,0005 %"},{"name":"","range":"0,001 Ω to 0,01 Ω","cmc":"1,0·10⁻⁵ · R + 0,02 µΩ"},{"name":"","range":"0,01 Ω to 200 kΩ","cmc":"0,0002 %"},{"name":"","range":"200 kΩ to 2 MΩ","cmc":"1,0·10⁻⁵ · R + 1,2 Ω"},{"name":"","range":"1 MΩ","cmc":"0,0004 %"},{"name":"","range":"2 MΩ to 20 MΩ","cmc":"1,7·10⁻⁵ · R + 15 Ω"},{"name":"","range":"20 MΩ to 200 MΩ","cmc":"7,0·10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"200 MΩ to 1 GΩ","cmc":"1,7·10⁻⁴ · R + 120 kΩ"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,04 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,1 %"},{"name":"","range":"100 GΩ to 1 TΩ","cmc":"0,4 %"}],"regulatory_area_zh":"直流电阻","search_zh":"固定电阻器 可调电阻器 校准器 示波器 分流器 测量卡 校准 — 直流电阻 内部程序；直接法和间接法；在固定地点 (S) 及固定地点以外 (P) 直流电阻 内部程序 直接法和间接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/3 LMEEiO/4 LMEEiO/13 LMEEiO/45","technique_zh":"内部程序；直接法和间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法和间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"固定电阻器\n可调电阻器\n校准器\n示波器\n分流器\n测量卡","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0 Ω to 0,0001 Ω","cmc":"2,0·10⁻⁴ · R + 0,02 µΩ"},{"name":"","range":"0,0001 Ω","cmc":"0,002 %"},{"name":"","range":"0,001 Ω","cmc":"0,0005 %"},{"name":"","range":"0,001 Ω to 0,01 Ω","cmc":"1,0·10⁻⁵ · R + 0,02 µΩ"},{"name":"","range":"0,01 Ω to 200 kΩ","cmc":"0,0002 %"},{"name":"","range":"200 kΩ to 2 MΩ","cmc":"1,0·10⁻⁵ · R + 1,2 Ω"},{"name":"","range":"1 MΩ","cmc":"0,0004 %"},{"name":"","range":"2 MΩ to 20 MΩ","cmc":"1,7·10⁻⁵ · R + 15 Ω"},{"name":"","range":"20 MΩ to 200 MΩ","cmc":"7,0·10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"200 MΩ to 1 GΩ","cmc":"1,7·10⁻⁴ · R + 120 kΩ"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,04 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,1 %"},{"name":"","range":"100 GΩ to 1 TΩ","cmc":"0,4 %"}],"regulatory_area_cs":"Odpor DC","search_cs":"Pevné rezistory Nastavitelné rezistory Kalibrátory Osciloskopy Bočníky Měřicí karty Kalibrace — Odpor DC Vnitřní postup; Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P) Odpor DC Vnitřní postup Přímá a nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/3 LMEEiO/4 LMEEiO/13 LMEEiO/45","technique_cs":"Vnitřní postup; Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá a nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Pevné rezistory\nNastavitelné rezistory\nKalibrátory\nOsciloskopy\nBočníky\nMěřicí karty"},{"_id":"b66c95d3850126421480628a","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki rezystancji\nMultimetry\nMierniki rezystancji izolacji\nMierniki RLC\nMostki\nMierniki rezystancji uziemienia\nMierniki parametrów sieci\nSkopometry\nKarty pomiarowe\nObciążenia elektroniczne\nAnalizatory parametrów i uszkodzeń linii","test_object_en":"Ohmmeters\nMultimeters\nInsulation resistance meters\nRLC meters\nBridges\nEarth resistance meters\nPower network parameter meters\nScopemeters\nData acquisition cards\nElectronic loads\nLine parameter and fault analysers","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0 Ω","cmc":"0,05 µΩ"},{"name":"","range":"0,00001 Ω","cmc":"0,02 %"},{"name":"","range":"0,0001 Ω","cmc":"0,002 %"},{"name":"","range":"0,0001 Ω do 0,001 Ω","cmc":"1,0·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"0,001 Ω","cmc":"0,0005%"},{"name":"","range":"0,001 Ω do 0,1 Ω","cmc":"1,7·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"0,01 Ω","cmc":"0,0002 %"},{"name":"","range":"0,1 Ω","cmc":"0,0002 %"},{"name":"","range":"0,1 Ω do 2 Ω","cmc":"1,7·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"1 Ω","cmc":"0,0002 %"},{"name":"","range":"2 Ω do 20 Ω","cmc":"1,1·10⁻⁵ · R + 15 µΩ"},{"name":"","range":"10 Ω","cmc":"0,0002 %"},{"name":"","range":"20 Ω do 200 Ω","cmc":"9,0·10⁻⁶ · R + 50 µΩ"},{"name":"","range":"25 Ω","cmc":"0,0002 %"},{"name":"","range":"100 Ω","cmc":"0,0002 %"},{"name":"","range":"200 Ω do 2 kΩ","cmc":"9,0·10⁻⁶ · R + 0,5 mΩ"},{"name":"","range":"1 kΩ","cmc":"0,0002 %"},{"name":"","range":"2 kΩ do 20 kΩ","cmc":"9,0·10⁻⁶ · R + 0,005 Ω"},{"name":"","range":"10 kΩ","cmc":"0,0002 %"},{"name":"","range":"20 kΩ do 200 kΩ","cmc":"9,0·10⁻⁶ · R + 0,05 Ω"},{"name":"","range":"100 kΩ","cmc":"0,0002 %"},{"name":"","range":"200 kΩ do 2 MΩ","cmc":"1,0·10⁻⁵ · R + 1,2 Ω"},{"name":"","range":"1 MΩ","cmc":"0,0004 %"},{"name":"","range":"2 MΩ do 20 MΩ","cmc":"1,7·10⁻⁵ · R + 15 Ω"},{"name":"","range":"20 MΩ do 100 MΩ","cmc":"7,0·10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"100 MΩ do 1 GΩ","cmc":"1,7·10⁻⁴ · R + 120 kΩ"},{"name":"","range":"1 GΩ do 10 GΩ","cmc":"0,04 %"},{"name":"","range":"10 GΩ do 100 GΩ","cmc":"0,1 %"},{"name":"","range":"100 GΩ do 1 TΩ","cmc":"0,4 %"}],"parameters_en":[{"name":"","range":"0 Ω","cmc":"0,05 µΩ"},{"name":"","range":"0,00001 Ω","cmc":"0,02 %"},{"name":"","range":"0,0001 Ω","cmc":"0,002 %"},{"name":"","range":"0,0001 Ω to 0,001 Ω","cmc":"1,0·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"0,001 Ω","cmc":"0,0005%"},{"name":"","range":"0,001 Ω to 0,1 Ω","cmc":"1,7·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"0,01 Ω","cmc":"0,0002 %"},{"name":"","range":"0,1 Ω","cmc":"0,0002 %"},{"name":"","range":"0,1 Ω to 2 Ω","cmc":"1,7·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"1 Ω","cmc":"0,0002 %"},{"name":"","range":"2 Ω to 20 Ω","cmc":"1,1·10⁻⁵ · R + 15 µΩ"},{"name":"","range":"10 Ω","cmc":"0,0002 %"},{"name":"","range":"20 Ω to 200 Ω","cmc":"9,0·10⁻⁶ · R + 50 µΩ"},{"name":"","range":"25 Ω","cmc":"0,0002 %"},{"name":"","range":"100 Ω","cmc":"0,0002 %"},{"name":"","range":"200 Ω to 2 kΩ","cmc":"9,0·10⁻⁶ · R + 0,5 mΩ"},{"name":"","range":"1 kΩ","cmc":"0,0002 %"},{"name":"","range":"2 kΩ to 20 kΩ","cmc":"9,0·10⁻⁶ · R + 0,005 Ω"},{"name":"","range":"10 kΩ","cmc":"0,0002 %"},{"name":"","range":"20 kΩ to 200 kΩ","cmc":"9,0·10⁻⁶ · R + 0,05 Ω"},{"name":"","range":"100 kΩ","cmc":"0,0002 %"},{"name":"","range":"200 kΩ to 2 MΩ","cmc":"1,0·10⁻⁵ · R + 1,2 Ω"},{"name":"","range":"1 MΩ","cmc":"0,0004 %"},{"name":"","range":"2 MΩ to 20 MΩ","cmc":"1,7·10⁻⁵ · R + 15 Ω"},{"name":"","range":"20 MΩ to 100 MΩ","cmc":"7,0·10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"1,7·10⁻⁴ · R + 120 kΩ"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,04 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,1 %"},{"name":"","range":"100 GΩ to 1 TΩ","cmc":"0,4 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0 Ω CMC 0,05 µΩ\n0,00001 Ω CMC 0,02 %\n0,0001 Ω CMC 0,002 %\n0,0001 Ω do 0,001 Ω CMC 1,0·10⁻⁵ · R + 5 µΩ\n0,001 Ω CMC 0,0005%\n0,001 Ω do 0,1 Ω CMC 1,7·10⁻⁵ · R + 5 µΩ\n0,01 Ω CMC 0,0002 %\n0,1 Ω CMC 0,0002 %\n0,1 Ω do 2 Ω CMC 1,7·10⁻⁵ · R + 5 µΩ\n1 Ω CMC 0,0002 %\n2 Ω do 20 Ω CMC 1,1·10⁻⁵ · R + 15 µΩ\n10 Ω CMC 0,0002 %\n20 Ω do 200 Ω CMC 9,0·10⁻⁶ · R + 50 µΩ\n25 Ω CMC 0,0002 %\n100 Ω CMC 0,0002 %\n200 Ω do 2 kΩ CMC 9,0·10⁻⁶ · R + 0,5 mΩ\n1 kΩ CMC 0,0002 %\n2 kΩ do 20 kΩ CMC 9,0·10⁻⁶ · R + 0,005 Ω\n10 kΩ CMC 0,0002 %\n20 kΩ do 200 kΩ CMC 9,0·10⁻⁶ · R + 0,05 Ω\n100 kΩ CMC 0,0002 %\n200 kΩ do 2 MΩ CMC 1,0·10⁻⁵ · R + 1,2 Ω\n1 MΩ CMC 0,0004 %\n2 MΩ do 20 MΩ CMC 1,7·10⁻⁵ · R + 15 Ω\n20 MΩ do 100 MΩ CMC 7,0·10⁻⁵ · R + 1,2 kΩ\n100 MΩ do 1 GΩ CMC 1,7·10⁻⁴ · R + 120 kΩ\n1 GΩ do 10 GΩ CMC 0,04 %\n10 GΩ do 100 GΩ CMC 0,1 %\n100 GΩ do 1 TΩ CMC 0,4 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/42","norm_bases":["LMEEiO/2","EURAMET cg-15 v. 3.0","LMEEiO/5","LMEEiO/35","LMEEiO/42"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"S, P","note":"R – wielkość mierzona (Ω). Analizatory parametrów i uszkodzeń linii — wyłącznie w stałej lokalizacji (S)","note_en":"R – measured value (Ω). Line parameter and fault analysers — at permanent location only (S)","search_text":"Mierniki rezystancji\nMultimetry\nMierniki rezystancji izolacji\nMierniki RLC\nMostki\nMierniki rezystancji uziemienia\nMierniki parametrów sieci\nSkopometry\nKarty pomiarowe\nObciążenia elektroniczne\nAnalizatory parametrów i uszkodzeń linii Wzorcowanie — Rezystancja DC\nZakres:\n0 Ω CMC 0,05 µΩ\n0,00001 Ω CMC 0,02 %\n0,0001 Ω CMC 0,002 %\n0,0001 Ω do 0,001 Ω CMC 1,0·10⁻⁵ · R + 5 µΩ\n0,001 Ω CMC 0,0005%\n0,001 Ω do 0,1 Ω CMC 1,7·10⁻⁵ · R + 5 µΩ\n0,01 Ω CMC 0,0002 %\n0,1 Ω CMC 0,0002 %\n0,1 Ω do 2 Ω CMC 1,7·10⁻⁵ · R + 5 µΩ\n1 Ω CMC 0,0002 %\n2 Ω do 20 Ω CMC 1,1·10⁻⁵ · R + 15 µΩ\n10 Ω CMC 0,0002 %\n20 Ω do 200 Ω CMC 9,0·10⁻⁶ · R + 50 µΩ\n25 Ω CMC 0,0002 %\n100 Ω CMC 0,0002 %\n200 Ω do 2 kΩ CMC 9,0·10⁻⁶ · R + 0,5 mΩ\n1 kΩ CMC 0,0002 %\n2 kΩ do 20 kΩ CMC 9,0·10⁻⁶ · R + 0,005 Ω\n10 kΩ CMC 0,0002 %\n20 kΩ do 200 kΩ CMC 9,0·10⁻⁶ · R + 0,05 Ω\n100 kΩ CMC 0,0002 %\n200 kΩ do 2 MΩ CMC 1,0·10⁻⁵ · R + 1,2 Ω\n1 MΩ CMC 0,0004 %\n2 MΩ do 20 MΩ CMC 1,7·10⁻⁵ · R + 15 Ω\n20 MΩ do 100 MΩ CMC 7,0·10⁻⁵ · R + 1,2 kΩ\n100 MΩ do 1 GΩ CMC 1,7·10⁻⁴ · R + 120 kΩ\n1 GΩ do 10 GΩ CMC 0,04 %\n10 GΩ do 100 GΩ CMC 0,1 %\n100 GΩ do 1 TΩ CMC 0,4 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/42 Mierniki rezystancji\nMultimetry\nMierniki rezystancji izolacji\nMierniki RLC\nMostki\nMierniki rezystancji uziemienia\nMierniki parametrow sieci\nSkopometry\nKarty pomiarowe\nObciazenia elektroniczne\nAnalizatory parametrow i uszkodzen linii Wzorcowanie — Rezystancja DC\nZakres:\n0 Ω CMC 0,05 µΩ\n0,00001 Ω CMC 0,02 %\n0,0001 Ω CMC 0,002 %\n0,0001 Ω do 0,001 Ω CMC 1,0·10⁻⁵ · R + 5 µΩ\n0,001 Ω CMC 0,0005%\n0,001 Ω do 0,1 Ω CMC 1,7·10⁻⁵ · R + 5 µΩ\n0,01 Ω CMC 0,0002 %\n0,1 Ω CMC 0,0002 %\n0,1 Ω do 2 Ω CMC 1,7·10⁻⁵ · R + 5 µΩ\n1 Ω CMC 0,0002 %\n2 Ω do 20 Ω CMC 1,1·10⁻⁵ · R + 15 µΩ\n10 Ω CMC 0,0002 %\n20 Ω do 200 Ω CMC 9,0·10⁻⁶ · R + 50 µΩ\n25 Ω CMC 0,0002 %\n100 Ω CMC 0,0002 %\n200 Ω do 2 kΩ CMC 9,0·10⁻⁶ · R + 0,5 mΩ\n1 kΩ CMC 0,0002 %\n2 kΩ do 20 kΩ CMC 9,0·10⁻⁶ · R + 0,005 Ω\n10 kΩ CMC 0,0002 %\n20 kΩ do 200 kΩ CMC 9,0·10⁻⁶ · R + 0,05 Ω\n100 kΩ CMC 0,0002 %\n200 kΩ do 2 MΩ CMC 1,0·10⁻⁵ · R + 1,2 Ω\n1 MΩ CMC 0,0004 %\n2 MΩ do 20 MΩ CMC 1,7·10⁻⁵ · R + 15 Ω\n20 MΩ do 100 MΩ CMC 7,0·10⁻⁵ · R + 1,2 kΩ\n100 MΩ do 1 GΩ CMC 1,7·10⁻⁴ · R + 120 kΩ\n1 GΩ do 10 GΩ CMC 0,04 %\n10 GΩ do 100 GΩ CMC 0,1 %\n100 GΩ do 1 TΩ CMC 0,4 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/42","search_en":"Ohmmeters Multimeters Insulation resistance meters RLC meters Bridges Earth resistance meters Power network parameter meters Scopemeters Data acquisition cards Electronic loads Line parameter and fault analysers Calibration — DC resistance Internal procedure; Direct method; At permanent location (S) and outside of it (P) DC resistance Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/2 based on EURAMET cg-15 v. 3.0 LMEEiO/5 LMEEiO/35 LMEEiO/42","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":20,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/2 based on EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/42","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0 Ω","cmc":"0,05 µΩ"},{"name":"","range":"0,00001 Ω","cmc":"0,02 %"},{"name":"","range":"0,0001 Ω","cmc":"0,002 %"},{"name":"","range":"0,0001 Ω to 0,001 Ω","cmc":"1,0·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"0,001 Ω","cmc":"0,0005%"},{"name":"","range":"0,001 Ω to 0,1 Ω","cmc":"1,7·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"0,01 Ω","cmc":"0,0002 %"},{"name":"","range":"0,1 Ω","cmc":"0,0002 %"},{"name":"","range":"0,1 Ω to 2 Ω","cmc":"1,7·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"1 Ω","cmc":"0,0002 %"},{"name":"","range":"2 Ω to 20 Ω","cmc":"1,1·10⁻⁵ · R + 15 µΩ"},{"name":"","range":"10 Ω","cmc":"0,0002 %"},{"name":"","range":"20 Ω to 200 Ω","cmc":"9,0·10⁻⁶ · R + 50 µΩ"},{"name":"","range":"25 Ω","cmc":"0,0002 %"},{"name":"","range":"100 Ω","cmc":"0,0002 %"},{"name":"","range":"200 Ω to 2 kΩ","cmc":"9,0·10⁻⁶ · R + 0,5 mΩ"},{"name":"","range":"1 kΩ","cmc":"0,0002 %"},{"name":"","range":"2 kΩ to 20 kΩ","cmc":"9,0·10⁻⁶ · R + 0,005 Ω"},{"name":"","range":"10 kΩ","cmc":"0,0002 %"},{"name":"","range":"20 kΩ to 200 kΩ","cmc":"9,0·10⁻⁶ · R + 0,05 Ω"},{"name":"","range":"100 kΩ","cmc":"0,0002 %"},{"name":"","range":"200 kΩ to 2 MΩ","cmc":"1,0·10⁻⁵ · R + 1,2 Ω"},{"name":"","range":"1 MΩ","cmc":"0,0004 %"},{"name":"","range":"2 MΩ to 20 MΩ","cmc":"1,7·10⁻⁵ · R + 15 Ω"},{"name":"","range":"20 MΩ to 100 MΩ","cmc":"7,0·10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"1,7·10⁻⁴ · R + 120 kΩ"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,04 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,1 %"},{"name":"","range":"100 GΩ to 1 TΩ","cmc":"0,4 %"}],"reference_de":"LMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/42","regulatory_area_de":"DC-Widerstand","search_de":"Widerstandsmessgeräte Multimeter Isolationswiderstandsmessgeräte RLC-Messgeräte Messbrücken Erdungswiderstandsmessgeräte Netzparametermessgeräte Scopemeter Messkarten Elektronische Lasten Leitungsparameter- und Fehleranalysatoren Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Widerstand Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0 LMEEiO/5 LMEEiO/35 LMEEiO/42","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Widerstandsmessgeräte\nMultimeter\nIsolationswiderstandsmessgeräte\nRLC-Messgeräte\nMessbrücken\nErdungswiderstandsmessgeräte\nNetzparametermessgeräte\nScopemeter\nMesskarten\nElektronische Lasten\nLeitungsparameter- und Fehleranalysatoren","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0 Ω","cmc":"0,05 µΩ"},{"name":"","range":"0,00001 Ω","cmc":"0,02 %"},{"name":"","range":"0,0001 Ω","cmc":"0,002 %"},{"name":"","range":"0,0001 Ω to 0,001 Ω","cmc":"1,0·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"0,001 Ω","cmc":"0,0005%"},{"name":"","range":"0,001 Ω to 0,1 Ω","cmc":"1,7·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"0,01 Ω","cmc":"0,0002 %"},{"name":"","range":"0,1 Ω","cmc":"0,0002 %"},{"name":"","range":"0,1 Ω to 2 Ω","cmc":"1,7·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"1 Ω","cmc":"0,0002 %"},{"name":"","range":"2 Ω to 20 Ω","cmc":"1,1·10⁻⁵ · R + 15 µΩ"},{"name":"","range":"10 Ω","cmc":"0,0002 %"},{"name":"","range":"20 Ω to 200 Ω","cmc":"9,0·10⁻⁶ · R + 50 µΩ"},{"name":"","range":"25 Ω","cmc":"0,0002 %"},{"name":"","range":"100 Ω","cmc":"0,0002 %"},{"name":"","range":"200 Ω to 2 kΩ","cmc":"9,0·10⁻⁶ · R + 0,5 mΩ"},{"name":"","range":"1 kΩ","cmc":"0,0002 %"},{"name":"","range":"2 kΩ to 20 kΩ","cmc":"9,0·10⁻⁶ · R + 0,005 Ω"},{"name":"","range":"10 kΩ","cmc":"0,0002 %"},{"name":"","range":"20 kΩ to 200 kΩ","cmc":"9,0·10⁻⁶ · R + 0,05 Ω"},{"name":"","range":"100 kΩ","cmc":"0,0002 %"},{"name":"","range":"200 kΩ to 2 MΩ","cmc":"1,0·10⁻⁵ · R + 1,2 Ω"},{"name":"","range":"1 MΩ","cmc":"0,0004 %"},{"name":"","range":"2 MΩ to 20 MΩ","cmc":"1,7·10⁻⁵ · R + 15 Ω"},{"name":"","range":"20 MΩ to 100 MΩ","cmc":"7,0·10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"1,7·10⁻⁴ · R + 120 kΩ"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,04 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,1 %"},{"name":"","range":"100 GΩ to 1 TΩ","cmc":"0,4 %"}],"reference_zh":"LMEEiO/2 依据EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/42","regulatory_area_zh":"直流电阻","search_zh":"电阻表 万用表 绝缘电阻测量仪 RLC 测量仪 电桥 接地电阻测量仪 电网参数测量仪 手持示波表 测量卡 电子负载 线路参数与故障分析仪 校准 — 直流电阻 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 直流电阻 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/2 依据EURAMET cg-15 v. 3.0 LMEEiO/5 LMEEiO/35 LMEEiO/42","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电阻表\n万用表\n绝缘电阻测量仪\nRLC 测量仪\n电桥\n接地电阻测量仪\n电网参数测量仪\n手持示波表\n测量卡\n电子负载\n线路参数与故障分析仪","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0 Ω","cmc":"0,05 µΩ"},{"name":"","range":"0,00001 Ω","cmc":"0,02 %"},{"name":"","range":"0,0001 Ω","cmc":"0,002 %"},{"name":"","range":"0,0001 Ω to 0,001 Ω","cmc":"1,0·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"0,001 Ω","cmc":"0,0005%"},{"name":"","range":"0,001 Ω to 0,1 Ω","cmc":"1,7·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"0,01 Ω","cmc":"0,0002 %"},{"name":"","range":"0,1 Ω","cmc":"0,0002 %"},{"name":"","range":"0,1 Ω to 2 Ω","cmc":"1,7·10⁻⁵ · R + 5 µΩ"},{"name":"","range":"1 Ω","cmc":"0,0002 %"},{"name":"","range":"2 Ω to 20 Ω","cmc":"1,1·10⁻⁵ · R + 15 µΩ"},{"name":"","range":"10 Ω","cmc":"0,0002 %"},{"name":"","range":"20 Ω to 200 Ω","cmc":"9,0·10⁻⁶ · R + 50 µΩ"},{"name":"","range":"25 Ω","cmc":"0,0002 %"},{"name":"","range":"100 Ω","cmc":"0,0002 %"},{"name":"","range":"200 Ω to 2 kΩ","cmc":"9,0·10⁻⁶ · R + 0,5 mΩ"},{"name":"","range":"1 kΩ","cmc":"0,0002 %"},{"name":"","range":"2 kΩ to 20 kΩ","cmc":"9,0·10⁻⁶ · R + 0,005 Ω"},{"name":"","range":"10 kΩ","cmc":"0,0002 %"},{"name":"","range":"20 kΩ to 200 kΩ","cmc":"9,0·10⁻⁶ · R + 0,05 Ω"},{"name":"","range":"100 kΩ","cmc":"0,0002 %"},{"name":"","range":"200 kΩ to 2 MΩ","cmc":"1,0·10⁻⁵ · R + 1,2 Ω"},{"name":"","range":"1 MΩ","cmc":"0,0004 %"},{"name":"","range":"2 MΩ to 20 MΩ","cmc":"1,7·10⁻⁵ · R + 15 Ω"},{"name":"","range":"20 MΩ to 100 MΩ","cmc":"7,0·10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"1,7·10⁻⁴ · R + 120 kΩ"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"0,04 %"},{"name":"","range":"10 GΩ to 100 GΩ","cmc":"0,1 %"},{"name":"","range":"100 GΩ to 1 TΩ","cmc":"0,4 %"}],"reference_cs":"LMEEiO/2 na základě EURAMET cg-15 v. 3.0\nLMEEiO/5\nLMEEiO/35\nLMEEiO/42","regulatory_area_cs":"Odpor DC","search_cs":"Měřiče odporu Multimetry Měřiče izolačního odporu Měřiče RLC Můstky Měřiče zemního odporu Měřiče parametrů sítě Skopmetry Měřicí karty Elektronické zátěže Analyzátory parametrů a poruch vedení Kalibrace — Odpor DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Odpor DC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/2 na základě EURAMET cg-15 v. 3.0 LMEEiO/5 LMEEiO/35 LMEEiO/42","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče odporu\nMultimetry\nMěřiče izolačního odporu\nMěřiče RLC\nMůstky\nMěřiče zemního odporu\nMěřiče parametrů sítě\nSkopmetry\nMěřicí karty\nElektronické zátěže\nAnalyzátory parametrů a poruch vedení"},{"_id":"a1b5248f3382a0e51dd475e8","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Rezystory wzorcowe\nRezystory regulowane/dekadowe\nWzorce rezystancji\nBoczniki\nMostki (mierniki) RLC\nMostki (mierniki) impedancji\nMierniki rezystancji\nMierniki (testery) parametrów instalacji elektrycznych\nMierniki rezystancji pętli zwarcia\nObciążenia elektroniczne","test_object_en":"Standard resistors\nVariable/decade resistors\nResistance standards\nShunts\nRLC bridges (meters)\nImpedance bridges (meters)\nOhmmeters\nElectrical installation parameter meters (testers)\nLoop impedance meters\nElectronic loads","methodology":"Wzorcowanie — Rezystancja AC","methodology_en":"Calibration — AC resistance","parameters":[{"name":"f = 1 kHz","range":"0,001 Ω do 1 Ω","cmc":"0,08 %"},{"name":"f = 1 kHz","range":"1 Ω do 100 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"100 Ω do 1 MΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"1 MΩ do 10 MΩ","cmc":"0,12 %"},{"name":"f = 40 Hz do 100 Hz","range":"0,01 Ω do 1 Ω","cmc":"0,08 %"},{"name":"f = 40 Hz do 100 Hz","range":"1 Ω do 10 Ω","cmc":"0,07 %"},{"name":"f = 40 Hz do 100 Hz","range":"10 Ω do 100 Ω","cmc":"0,06 %"},{"name":"f = 40 Hz do 100 Hz","range":"100 Ω do 10 kΩ","cmc":"0,05 %"},{"name":"f = 40 Hz do 100 Hz","range":"10 kΩ do 100 kΩ","cmc":"0,06 %"},{"name":"f = 40 Hz do 100 Hz","range":"100 kΩ do 1 MΩ","cmc":"0,09 %"},{"name":"f = 40 Hz do 100 Hz","range":"1 MΩ do 10 MΩ","cmc":"0,45 %"},{"name":"f = 100 Hz do 1 kHz","range":"0,01 Ω do 1 Ω","cmc":"0,08 %"},{"name":"f = 100 Hz do 1 kHz","range":"1 Ω do 10 Ω","cmc":"0,05 %"},{"name":"f = 100 Hz do 1 kHz","range":"10 Ω do 100 Ω","cmc":"0,04 %"},{"name":"f = 100 Hz do 1 kHz","range":"100 Ω do 10 kΩ","cmc":"0,03 %"},{"name":"f = 100 Hz do 1 kHz","range":"10 kΩ do 100 kΩ","cmc":"0,04 %"},{"name":"f = 100 Hz do 1 kHz","range":"100 kΩ do 1 MΩ","cmc":"0,05 %"},{"name":"f = 100 Hz do 1 kHz","range":"1 Ω do 10 MΩ","cmc":"0,23 %"},{"name":"f = 1 kHz do 3 kHz","range":"0,01 Ω do 1 Ω","cmc":"0,13 %"},{"name":"f = 1 kHz do 3 kHz","range":"1 Ω do 10 Ω","cmc":"0,09 %"},{"name":"f = 1 kHz do 3 kHz","range":"10 Ω do 100 Ω","cmc":"0,04 %"},{"name":"f = 1 kHz do 3 kHz","range":"100 Ω do 10 kΩ","cmc":"0,03 %"},{"name":"f = 1 kHz do 3 kHz","range":"10 kΩ do 100 kΩ","cmc":"0,04 %"},{"name":"f = 1 kHz do 3 kHz","range":"100 kΩ do 1 MΩ","cmc":"0,05 %"},{"name":"f = 1 kHz do 3 kHz","range":"1 MΩ do 10 MΩ","cmc":"0,23 %"},{"name":"f = 3 kHz do 6 kHz","range":"0,01 Ω do 1 Ω","cmc":"0,23 %"},{"name":"f = 3 kHz do 6 kHz","range":"1 Ω do 10 Ω","cmc":"0,09 %"},{"name":"f = 3 kHz do 6 kHz","range":"10 Ω do 100 Ω","cmc":"0,04 %"},{"name":"f = 3 kHz do 6 kHz","range":"100 Ω do 10 kΩ","cmc":"0,03 %"},{"name":"f = 3 kHz do 6 kHz","range":"10 kΩ do 100 kΩ","cmc":"0,08 %"},{"name":"f = 3 kHz do 6 kHz","range":"100 kΩ do 1 MΩ","cmc":"0,13 %"},{"name":"f = 3 kHz do 6 kHz","range":"1 MΩ do 10 MΩ","cmc":"0,67 %"},{"name":"f = 6 kHz do 10 kHz","range":"0,01 Ω do 1 Ω","cmc":"0,23 %"},{"name":"f = 6 kHz do 10 kHz","range":"1 Ω do 10 Ω","cmc":"0,17 %"},{"name":"f = 6 kHz do 10 kHz","range":"10 Ω do 100 Ω","cmc":"0,07 %"},{"name":"f = 6 kHz do 10 kHz","range":"100 Ω do 10 kΩ","cmc":"0,05 %"},{"name":"f = 6 kHz do 10 kHz","range":"10 kΩ do 100 kΩ","cmc":"0,19 %"},{"name":"f = 6 kHz do 10 kHz","range":"100 kΩ do 1 MΩ","cmc":"0,33 %"},{"name":"f = 10 kHz do 20 kHz","range":"1 Ω do 10 Ω","cmc":"0,25 %"},{"name":"f = 10 kHz do 20 kHz","range":"10 Ω do 100 Ω","cmc":"0,09 %"},{"name":"f = 10 kHz do 20 kHz","range":"100 Ω do 10 kΩ","cmc":"0,07 %"},{"name":"f = 10 kHz do 20 kHz","range":"10 kΩ do 100 kΩ","cmc":"0,29 %"},{"name":"f = 10 kHz do 20 kHz","range":"100 kΩ do 1 MΩ","cmc":"0,53 %"},{"name":"f = 20 kHz do 50 kHz","range":"1 Ω do 10 Ω","cmc":"0,37 %"},{"name":"f = 20 kHz do 50 kHz","range":"10 Ω do 100 Ω","cmc":"0,13 %"},{"name":"f = 20 kHz do 50 kHz","range":"100 Ω do 1 kΩ","cmc":"0,10 %"},{"name":"f = 20 kHz do 50 kHz","range":"1 kΩ do 10 kΩ","cmc":"0,12 %"},{"name":"f = 50 kHz do 100 kHz","range":"1 Ω do 10 Ω","cmc":"0,77 %"},{"name":"f = 50 kHz do 100 kHz","range":"10 Ω do 100 Ω","cmc":"0,26 %"},{"name":"f = 50 kHz do 100 kHz","range":"100 Ω do 1 kΩ","cmc":"0,20 %"},{"name":"f = 50 kHz do 100 kHz","range":"1 kΩ do 10 kΩ","cmc":"0,23 %"}],"parameters_en":[{"name":"f = 1 kHz","range":"0,001 Ω to 1 Ω","cmc":"0,08 %"},{"name":"f = 1 kHz","range":"1 Ω to 100 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"100 Ω to 1 MΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,12 %"},{"name":"f = 40 Hz to 100 Hz","range":"0,01 Ω to 1 Ω","cmc":"0,08 %"},{"name":"f = 40 Hz to 100 Hz","range":"1 Ω to 10 Ω","cmc":"0,07 %"},{"name":"f = 40 Hz to 100 Hz","range":"10 Ω to 100 Ω","cmc":"0,06 %"},{"name":"f = 40 Hz to 100 Hz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 40 Hz to 100 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,06 %"},{"name":"f = 40 Hz to 100 Hz","range":"100 kΩ to 1 MΩ","cmc":"0,09 %"},{"name":"f = 40 Hz to 100 Hz","range":"1 MΩ to 10 MΩ","cmc":"0,45 %"},{"name":"f = 100 Hz to 1 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,08 %"},{"name":"f = 100 Hz to 1 kHz","range":"1 Ω to 10 Ω","cmc":"0,05 %"},{"name":"f = 100 Hz to 1 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 100 Hz to 1 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 100 Hz to 1 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 100 Hz to 1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 100 Hz to 1 kHz","range":"1 Ω to 10 MΩ","cmc":"0,23 %"},{"name":"f = 1 kHz to 3 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,13 %"},{"name":"f = 1 kHz to 3 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 1 kHz to 3 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 1 kHz to 3 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 1 kHz to 3 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 1 kHz to 3 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 1 kHz to 3 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,23 %"},{"name":"f = 3 kHz to 6 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,23 %"},{"name":"f = 3 kHz to 6 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 3 kHz to 6 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 3 kHz to 6 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 3 kHz to 6 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,08 %"},{"name":"f = 3 kHz to 6 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,13 %"},{"name":"f = 3 kHz to 6 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,67 %"},{"name":"f = 6 kHz to 10 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,23 %"},{"name":"f = 6 kHz to 10 kHz","range":"1 Ω to 10 Ω","cmc":"0,17 %"},{"name":"f = 6 kHz to 10 kHz","range":"10 Ω to 100 Ω","cmc":"0,07 %"},{"name":"f = 6 kHz to 10 kHz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 6 kHz to 10 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,19 %"},{"name":"f = 6 kHz to 10 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,33 %"},{"name":"f = 10 kHz to 20 kHz","range":"1 Ω to 10 Ω","cmc":"0,25 %"},{"name":"f = 10 kHz to 20 kHz","range":"10 Ω to 100 Ω","cmc":"0,09 %"},{"name":"f = 10 kHz to 20 kHz","range":"100 Ω to 10 kΩ","cmc":"0,07 %"},{"name":"f = 10 kHz to 20 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,29 %"},{"name":"f = 10 kHz to 20 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,53 %"},{"name":"f = 20 kHz to 50 kHz","range":"1 Ω to 10 Ω","cmc":"0,37 %"},{"name":"f = 20 kHz to 50 kHz","range":"10 Ω to 100 Ω","cmc":"0,13 %"},{"name":"f = 20 kHz to 50 kHz","range":"100 Ω to 1 kΩ","cmc":"0,10 %"},{"name":"f = 20 kHz to 50 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,12 %"},{"name":"f = 50 kHz to 100 kHz","range":"1 Ω to 10 Ω","cmc":"0,77 %"},{"name":"f = 50 kHz to 100 kHz","range":"10 Ω to 100 Ω","cmc":"0,26 %"},{"name":"f = 50 kHz to 100 kHz","range":"100 Ω to 1 kΩ","cmc":"0,20 %"},{"name":"f = 50 kHz to 100 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,23 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja AC\nZakres:\nf = 1 kHz 0,001 Ω do 1 Ω CMC 0,08 %\nf = 1 kHz 1 Ω do 100 Ω CMC 0,03 %\nf = 1 kHz 100 Ω do 1 MΩ CMC 0,02 %\nf = 1 kHz 1 MΩ do 10 MΩ CMC 0,12 %\nf = 40 Hz do 100 Hz 0,01 Ω do 1 Ω CMC 0,08 %\nf = 40 Hz do 100 Hz 1 Ω do 10 Ω CMC 0,07 %\nf = 40 Hz do 100 Hz 10 Ω do 100 Ω CMC 0,06 %\nf = 40 Hz do 100 Hz 100 Ω do 10 kΩ CMC 0,05 %\nf = 40 Hz do 100 Hz 10 kΩ do 100 kΩ CMC 0,06 %\nf = 40 Hz do 100 Hz 100 kΩ do 1 MΩ CMC 0,09 %\nf = 40 Hz do 100 Hz 1 MΩ do 10 MΩ CMC 0,45 %\nf = 100 Hz do 1 kHz 0,01 Ω do 1 Ω CMC 0,08 %\nf = 100 Hz do 1 kHz 1 Ω do 10 Ω CMC 0,05 %\nf = 100 Hz do 1 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 100 Hz do 1 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 100 Hz do 1 kHz 10 kΩ do 100 kΩ CMC 0,04 %\nf = 100 Hz do 1 kHz 100 kΩ do 1 MΩ CMC 0,05 %\nf = 100 Hz do 1 kHz 1 Ω do 10 MΩ CMC 0,23 %\nf = 1 kHz do 3 kHz 0,01 Ω do 1 Ω CMC 0,13 %\nf = 1 kHz do 3 kHz 1 Ω do 10 Ω CMC 0,09 %\nf = 1 kHz do 3 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 1 kHz do 3 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 1 kHz do 3 kHz 10 kΩ do 100 kΩ CMC 0,04 %\nf = 1 kHz do 3 kHz 100 kΩ do 1 MΩ CMC 0,05 %\nf = 1 kHz do 3 kHz 1 MΩ do 10 MΩ CMC 0,23 %\nf = 3 kHz do 6 kHz 0,01 Ω do 1 Ω CMC 0,23 %\nf = 3 kHz do 6 kHz 1 Ω do 10 Ω CMC 0,09 %\nf = 3 kHz do 6 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 3 kHz do 6 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 3 kHz do 6 kHz 10 kΩ do 100 kΩ CMC 0,08 %\nf = 3 kHz do 6 kHz 100 kΩ do 1 MΩ CMC 0,13 %\nf = 3 kHz do 6 kHz 1 MΩ do 10 MΩ CMC 0,67 %\nf = 6 kHz do 10 kHz 0,01 Ω do 1 Ω CMC 0,23 %\nf = 6 kHz do 10 kHz 1 Ω do 10 Ω CMC 0,17 %\nf = 6 kHz do 10 kHz 10 Ω do 100 Ω CMC 0,07 %\nf = 6 kHz do 10 kHz 100 Ω do 10 kΩ CMC 0,05 %\nf = 6 kHz do 10 kHz 10 kΩ do 100 kΩ CMC 0,19 %\nf = 6 kHz do 10 kHz 100 kΩ do 1 MΩ CMC 0,33 %\nf = 10 kHz do 20 kHz 1 Ω do 10 Ω CMC 0,25 %\nf = 10 kHz do 20 kHz 10 Ω do 100 Ω CMC 0,09 %\nf = 10 kHz do 20 kHz 100 Ω do 10 kΩ CMC 0,07 %\nf = 10 kHz do 20 kHz 10 kΩ do 100 kΩ CMC 0,29 %\nf = 10 kHz do 20 kHz 100 kΩ do 1 MΩ CMC 0,53 %\nf = 20 kHz do 50 kHz 1 Ω do 10 Ω CMC 0,37 %\nf = 20 kHz do 50 kHz 10 Ω do 100 Ω CMC 0,13 %\nf = 20 kHz do 50 kHz 100 Ω do 1 kΩ CMC 0,10 %\nf = 20 kHz do 50 kHz 1 kΩ do 10 kΩ CMC 0,12 %\nf = 50 kHz do 100 kHz 1 Ω do 10 Ω CMC 0,77 %\nf = 50 kHz do 100 kHz 10 Ω do 100 Ω CMC 0,26 %\nf = 50 kHz do 100 kHz 100 Ω do 1 kΩ CMC 0,20 %\nf = 50 kHz do 100 kHz 1 kΩ do 10 kΩ CMC 0,23 %\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/5\nLMEEiO/14\nLMEEiO/35\nLMEEiO/53","norm_bases":["LMEEiO/5","LMEEiO/14","LMEEiO/35","LMEEiO/53"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja AC","regulatory_area_en":"AC resistance","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Rezystory wzorcowe\nRezystory regulowane/dekadowe\nWzorce rezystancji\nBoczniki\nMostki (mierniki) RLC\nMostki (mierniki) impedancji\nMierniki rezystancji\nMierniki (testery) parametrów instalacji elektrycznych\nMierniki rezystancji pętli zwarcia\nObciążenia elektroniczne Wzorcowanie — Rezystancja AC\nZakres:\nf = 1 kHz 0,001 Ω do 1 Ω CMC 0,08 %\nf = 1 kHz 1 Ω do 100 Ω CMC 0,03 %\nf = 1 kHz 100 Ω do 1 MΩ CMC 0,02 %\nf = 1 kHz 1 MΩ do 10 MΩ CMC 0,12 %\nf = 40 Hz do 100 Hz 0,01 Ω do 1 Ω CMC 0,08 %\nf = 40 Hz do 100 Hz 1 Ω do 10 Ω CMC 0,07 %\nf = 40 Hz do 100 Hz 10 Ω do 100 Ω CMC 0,06 %\nf = 40 Hz do 100 Hz 100 Ω do 10 kΩ CMC 0,05 %\nf = 40 Hz do 100 Hz 10 kΩ do 100 kΩ CMC 0,06 %\nf = 40 Hz do 100 Hz 100 kΩ do 1 MΩ CMC 0,09 %\nf = 40 Hz do 100 Hz 1 MΩ do 10 MΩ CMC 0,45 %\nf = 100 Hz do 1 kHz 0,01 Ω do 1 Ω CMC 0,08 %\nf = 100 Hz do 1 kHz 1 Ω do 10 Ω CMC 0,05 %\nf = 100 Hz do 1 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 100 Hz do 1 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 100 Hz do 1 kHz 10 kΩ do 100 kΩ CMC 0,04 %\nf = 100 Hz do 1 kHz 100 kΩ do 1 MΩ CMC 0,05 %\nf = 100 Hz do 1 kHz 1 Ω do 10 MΩ CMC 0,23 %\nf = 1 kHz do 3 kHz 0,01 Ω do 1 Ω CMC 0,13 %\nf = 1 kHz do 3 kHz 1 Ω do 10 Ω CMC 0,09 %\nf = 1 kHz do 3 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 1 kHz do 3 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 1 kHz do 3 kHz 10 kΩ do 100 kΩ CMC 0,04 %\nf = 1 kHz do 3 kHz 100 kΩ do 1 MΩ CMC 0,05 %\nf = 1 kHz do 3 kHz 1 MΩ do 10 MΩ CMC 0,23 %\nf = 3 kHz do 6 kHz 0,01 Ω do 1 Ω CMC 0,23 %\nf = 3 kHz do 6 kHz 1 Ω do 10 Ω CMC 0,09 %\nf = 3 kHz do 6 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 3 kHz do 6 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 3 kHz do 6 kHz 10 kΩ do 100 kΩ CMC 0,08 %\nf = 3 kHz do 6 kHz 100 kΩ do 1 MΩ CMC 0,13 %\nf = 3 kHz do 6 kHz 1 MΩ do 10 MΩ CMC 0,67 %\nf = 6 kHz do 10 kHz 0,01 Ω do 1 Ω CMC 0,23 %\nf = 6 kHz do 10 kHz 1 Ω do 10 Ω CMC 0,17 %\nf = 6 kHz do 10 kHz 10 Ω do 100 Ω CMC 0,07 %\nf = 6 kHz do 10 kHz 100 Ω do 10 kΩ CMC 0,05 %\nf = 6 kHz do 10 kHz 10 kΩ do 100 kΩ CMC 0,19 %\nf = 6 kHz do 10 kHz 100 kΩ do 1 MΩ CMC 0,33 %\nf = 10 kHz do 20 kHz 1 Ω do 10 Ω CMC 0,25 %\nf = 10 kHz do 20 kHz 10 Ω do 100 Ω CMC 0,09 %\nf = 10 kHz do 20 kHz 100 Ω do 10 kΩ CMC 0,07 %\nf = 10 kHz do 20 kHz 10 kΩ do 100 kΩ CMC 0,29 %\nf = 10 kHz do 20 kHz 100 kΩ do 1 MΩ CMC 0,53 %\nf = 20 kHz do 50 kHz 1 Ω do 10 Ω CMC 0,37 %\nf = 20 kHz do 50 kHz 10 Ω do 100 Ω CMC 0,13 %\nf = 20 kHz do 50 kHz 100 Ω do 1 kΩ CMC 0,10 %\nf = 20 kHz do 50 kHz 1 kΩ do 10 kΩ CMC 0,12 %\nf = 50 kHz do 100 kHz 1 Ω do 10 Ω CMC 0,77 %\nf = 50 kHz do 100 kHz 10 Ω do 100 Ω CMC 0,26 %\nf = 50 kHz do 100 kHz 100 Ω do 1 kΩ CMC 0,20 %\nf = 50 kHz do 100 kHz 1 kΩ do 10 kΩ CMC 0,23 %\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/5\nLMEEiO/14\nLMEEiO/35\nLMEEiO/53 Rezystory wzorcowe\nRezystory regulowane/dekadowe\nWzorce rezystancji\nBoczniki\nMostki (mierniki) RLC\nMostki (mierniki) impedancji\nMierniki rezystancji\nMierniki (testery) parametrow instalacji elektrycznych\nMierniki rezystancji petli zwarcia\nObciazenia elektroniczne Wzorcowanie — Rezystancja AC\nZakres:\nf = 1 kHz 0,001 Ω do 1 Ω CMC 0,08 %\nf = 1 kHz 1 Ω do 100 Ω CMC 0,03 %\nf = 1 kHz 100 Ω do 1 MΩ CMC 0,02 %\nf = 1 kHz 1 MΩ do 10 MΩ CMC 0,12 %\nf = 40 Hz do 100 Hz 0,01 Ω do 1 Ω CMC 0,08 %\nf = 40 Hz do 100 Hz 1 Ω do 10 Ω CMC 0,07 %\nf = 40 Hz do 100 Hz 10 Ω do 100 Ω CMC 0,06 %\nf = 40 Hz do 100 Hz 100 Ω do 10 kΩ CMC 0,05 %\nf = 40 Hz do 100 Hz 10 kΩ do 100 kΩ CMC 0,06 %\nf = 40 Hz do 100 Hz 100 kΩ do 1 MΩ CMC 0,09 %\nf = 40 Hz do 100 Hz 1 MΩ do 10 MΩ CMC 0,45 %\nf = 100 Hz do 1 kHz 0,01 Ω do 1 Ω CMC 0,08 %\nf = 100 Hz do 1 kHz 1 Ω do 10 Ω CMC 0,05 %\nf = 100 Hz do 1 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 100 Hz do 1 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 100 Hz do 1 kHz 10 kΩ do 100 kΩ CMC 0,04 %\nf = 100 Hz do 1 kHz 100 kΩ do 1 MΩ CMC 0,05 %\nf = 100 Hz do 1 kHz 1 Ω do 10 MΩ CMC 0,23 %\nf = 1 kHz do 3 kHz 0,01 Ω do 1 Ω CMC 0,13 %\nf = 1 kHz do 3 kHz 1 Ω do 10 Ω CMC 0,09 %\nf = 1 kHz do 3 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 1 kHz do 3 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 1 kHz do 3 kHz 10 kΩ do 100 kΩ CMC 0,04 %\nf = 1 kHz do 3 kHz 100 kΩ do 1 MΩ CMC 0,05 %\nf = 1 kHz do 3 kHz 1 MΩ do 10 MΩ CMC 0,23 %\nf = 3 kHz do 6 kHz 0,01 Ω do 1 Ω CMC 0,23 %\nf = 3 kHz do 6 kHz 1 Ω do 10 Ω CMC 0,09 %\nf = 3 kHz do 6 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 3 kHz do 6 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 3 kHz do 6 kHz 10 kΩ do 100 kΩ CMC 0,08 %\nf = 3 kHz do 6 kHz 100 kΩ do 1 MΩ CMC 0,13 %\nf = 3 kHz do 6 kHz 1 MΩ do 10 MΩ CMC 0,67 %\nf = 6 kHz do 10 kHz 0,01 Ω do 1 Ω CMC 0,23 %\nf = 6 kHz do 10 kHz 1 Ω do 10 Ω CMC 0,17 %\nf = 6 kHz do 10 kHz 10 Ω do 100 Ω CMC 0,07 %\nf = 6 kHz do 10 kHz 100 Ω do 10 kΩ CMC 0,05 %\nf = 6 kHz do 10 kHz 10 kΩ do 100 kΩ CMC 0,19 %\nf = 6 kHz do 10 kHz 100 kΩ do 1 MΩ CMC 0,33 %\nf = 10 kHz do 20 kHz 1 Ω do 10 Ω CMC 0,25 %\nf = 10 kHz do 20 kHz 10 Ω do 100 Ω CMC 0,09 %\nf = 10 kHz do 20 kHz 100 Ω do 10 kΩ CMC 0,07 %\nf = 10 kHz do 20 kHz 10 kΩ do 100 kΩ CMC 0,29 %\nf = 10 kHz do 20 kHz 100 kΩ do 1 MΩ CMC 0,53 %\nf = 20 kHz do 50 kHz 1 Ω do 10 Ω CMC 0,37 %\nf = 20 kHz do 50 kHz 10 Ω do 100 Ω CMC 0,13 %\nf = 20 kHz do 50 kHz 100 Ω do 1 kΩ CMC 0,10 %\nf = 20 kHz do 50 kHz 1 kΩ do 10 kΩ CMC 0,12 %\nf = 50 kHz do 100 kHz 1 Ω do 10 Ω CMC 0,77 %\nf = 50 kHz do 100 kHz 10 Ω do 100 Ω CMC 0,26 %\nf = 50 kHz do 100 kHz 100 Ω do 1 kΩ CMC 0,20 %\nf = 50 kHz do 100 kHz 1 kΩ do 10 kΩ CMC 0,23 %\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/5\nLMEEiO/14\nLMEEiO/35\nLMEEiO/53","search_en":"Standard resistors Variable/decade resistors Resistance standards Shunts RLC bridges (meters) Impedance bridges (meters) Ohmmeters Electrical installation parameter meters (testers) Loop impedance meters Electronic loads Calibration — AC resistance Internal procedure; At permanent location (S) and outside of it (P) AC resistance Internal procedure At permanent location (S) and outside of it (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 100 Hz to 1 kHz f = 100 Hz to 1 kHz f = 100 Hz to 1 kHz f = 100 Hz to 1 kHz f = 100 Hz to 1 kHz f = 100 Hz to 1 kHz f = 100 Hz to 1 kHz f = 1 kHz to 3 kHz f = 1 kHz to 3 kHz f = 1 kHz to 3 kHz f = 1 kHz to 3 kHz f = 1 kHz to 3 kHz f = 1 kHz to 3 kHz f = 1 kHz to 3 kHz f = 3 kHz to 6 kHz f = 3 kHz to 6 kHz f = 3 kHz to 6 kHz f = 3 kHz to 6 kHz f = 3 kHz to 6 kHz f = 3 kHz to 6 kHz f = 3 kHz to 6 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz LMEEiO/5 LMEEiO/14 LMEEiO/35 LMEEiO/53","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":21,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstromwiderstand","parameters_de":[{"name":"f = 1 kHz","range":"0,001 Ω to 1 Ω","cmc":"0,08 %"},{"name":"f = 1 kHz","range":"1 Ω to 100 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"100 Ω to 1 MΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,12 %"},{"name":"f = 40 Hz bis 100 Hz","range":"0,01 Ω to 1 Ω","cmc":"0,08 %"},{"name":"f = 40 Hz bis 100 Hz","range":"1 Ω to 10 Ω","cmc":"0,07 %"},{"name":"f = 40 Hz bis 100 Hz","range":"10 Ω to 100 Ω","cmc":"0,06 %"},{"name":"f = 40 Hz bis 100 Hz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 40 Hz bis 100 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,06 %"},{"name":"f = 40 Hz bis 100 Hz","range":"100 kΩ to 1 MΩ","cmc":"0,09 %"},{"name":"f = 40 Hz bis 100 Hz","range":"1 MΩ to 10 MΩ","cmc":"0,45 %"},{"name":"f = 100 Hz bis 1 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,08 %"},{"name":"f = 100 Hz bis 1 kHz","range":"1 Ω to 10 Ω","cmc":"0,05 %"},{"name":"f = 100 Hz bis 1 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 100 Hz bis 1 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 100 Hz bis 1 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 100 Hz bis 1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 100 Hz bis 1 kHz","range":"1 Ω to 10 MΩ","cmc":"0,23 %"},{"name":"f = 1 kHz bis 3 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,13 %"},{"name":"f = 1 kHz bis 3 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 1 kHz bis 3 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 1 kHz bis 3 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 1 kHz bis 3 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 1 kHz bis 3 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 1 kHz bis 3 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,23 %"},{"name":"f = 3 kHz bis 6 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,23 %"},{"name":"f = 3 kHz bis 6 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 3 kHz bis 6 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 3 kHz bis 6 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 3 kHz bis 6 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,08 %"},{"name":"f = 3 kHz bis 6 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,13 %"},{"name":"f = 3 kHz bis 6 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,67 %"},{"name":"f = 6 kHz bis 10 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,23 %"},{"name":"f = 6 kHz bis 10 kHz","range":"1 Ω to 10 Ω","cmc":"0,17 %"},{"name":"f = 6 kHz bis 10 kHz","range":"10 Ω to 100 Ω","cmc":"0,07 %"},{"name":"f = 6 kHz bis 10 kHz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 6 kHz bis 10 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,19 %"},{"name":"f = 6 kHz bis 10 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,33 %"},{"name":"f = 10 kHz bis 20 kHz","range":"1 Ω to 10 Ω","cmc":"0,25 %"},{"name":"f = 10 kHz bis 20 kHz","range":"10 Ω to 100 Ω","cmc":"0,09 %"},{"name":"f = 10 kHz bis 20 kHz","range":"100 Ω to 10 kΩ","cmc":"0,07 %"},{"name":"f = 10 kHz bis 20 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,29 %"},{"name":"f = 10 kHz bis 20 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,53 %"},{"name":"f = 20 kHz bis 50 kHz","range":"1 Ω to 10 Ω","cmc":"0,37 %"},{"name":"f = 20 kHz bis 50 kHz","range":"10 Ω to 100 Ω","cmc":"0,13 %"},{"name":"f = 20 kHz bis 50 kHz","range":"100 Ω to 1 kΩ","cmc":"0,10 %"},{"name":"f = 20 kHz bis 50 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,12 %"},{"name":"f = 50 kHz bis 100 kHz","range":"1 Ω to 10 Ω","cmc":"0,77 %"},{"name":"f = 50 kHz bis 100 kHz","range":"10 Ω to 100 Ω","cmc":"0,26 %"},{"name":"f = 50 kHz bis 100 kHz","range":"100 Ω to 1 kΩ","cmc":"0,20 %"},{"name":"f = 50 kHz bis 100 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,23 %"}],"regulatory_area_de":"AC-Widerstand","search_de":"Normalwiderstände Einstellbare Widerstände/Dekadenwiderstände Widerstandsnormale Shunts RLC-Messbrücken (Messgeräte) Impedanzmessbrücken (Messgeräte) Widerstandsmessgeräte Messgeräte (Prüfgeräte) für Elektroinstallationsparameter Schleifenimpedanz-Messgeräte Elektronische Lasten Kalibrierung — Wechselstromwiderstand Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) AC-Widerstand Internes Verfahren Am festen Standort (S) und außerhalb (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 100 Hz bis 1 kHz f = 100 Hz bis 1 kHz f = 100 Hz bis 1 kHz f = 100 Hz bis 1 kHz f = 100 Hz bis 1 kHz f = 100 Hz bis 1 kHz f = 100 Hz bis 1 kHz f = 1 kHz bis 3 kHz f = 1 kHz bis 3 kHz f = 1 kHz bis 3 kHz f = 1 kHz bis 3 kHz f = 1 kHz bis 3 kHz f = 1 kHz bis 3 kHz f = 1 kHz bis 3 kHz f = 3 kHz bis 6 kHz f = 3 kHz bis 6 kHz f = 3 kHz bis 6 kHz f = 3 kHz bis 6 kHz f = 3 kHz bis 6 kHz f = 3 kHz bis 6 kHz f = 3 kHz bis 6 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz LMEEiO/5 LMEEiO/14 LMEEiO/35 LMEEiO/53","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Normalwiderstände\nEinstellbare Widerstände/Dekadenwiderstände\nWiderstandsnormale\nShunts\nRLC-Messbrücken (Messgeräte)\nImpedanzmessbrücken (Messgeräte)\nWiderstandsmessgeräte\nMessgeräte (Prüfgeräte) für Elektroinstallationsparameter\nSchleifenimpedanz-Messgeräte\nElektronische Lasten","methodology_zh":"校准 — 交流电阻","parameters_zh":[{"name":"f = 1 kHz","range":"0,001 Ω to 1 Ω","cmc":"0,08 %"},{"name":"f = 1 kHz","range":"1 Ω to 100 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"100 Ω to 1 MΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,12 %"},{"name":"f = 40 Hz 至 100 Hz","range":"0,01 Ω to 1 Ω","cmc":"0,08 %"},{"name":"f = 40 Hz 至 100 Hz","range":"1 Ω to 10 Ω","cmc":"0,07 %"},{"name":"f = 40 Hz 至 100 Hz","range":"10 Ω to 100 Ω","cmc":"0,06 %"},{"name":"f = 40 Hz 至 100 Hz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 40 Hz 至 100 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,06 %"},{"name":"f = 40 Hz 至 100 Hz","range":"100 kΩ to 1 MΩ","cmc":"0,09 %"},{"name":"f = 40 Hz 至 100 Hz","range":"1 MΩ to 10 MΩ","cmc":"0,45 %"},{"name":"f = 100 Hz 至 1 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,08 %"},{"name":"f = 100 Hz 至 1 kHz","range":"1 Ω to 10 Ω","cmc":"0,05 %"},{"name":"f = 100 Hz 至 1 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 100 Hz 至 1 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 100 Hz 至 1 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 100 Hz 至 1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 100 Hz 至 1 kHz","range":"1 Ω to 10 MΩ","cmc":"0,23 %"},{"name":"f = 1 kHz 至 3 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,13 %"},{"name":"f = 1 kHz 至 3 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 1 kHz 至 3 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 1 kHz 至 3 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 1 kHz 至 3 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 1 kHz 至 3 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 1 kHz 至 3 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,23 %"},{"name":"f = 3 kHz 至 6 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,23 %"},{"name":"f = 3 kHz 至 6 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 3 kHz 至 6 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 3 kHz 至 6 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 3 kHz 至 6 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,08 %"},{"name":"f = 3 kHz 至 6 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,13 %"},{"name":"f = 3 kHz 至 6 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,67 %"},{"name":"f = 6 kHz 至 10 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,23 %"},{"name":"f = 6 kHz 至 10 kHz","range":"1 Ω to 10 Ω","cmc":"0,17 %"},{"name":"f = 6 kHz 至 10 kHz","range":"10 Ω to 100 Ω","cmc":"0,07 %"},{"name":"f = 6 kHz 至 10 kHz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 6 kHz 至 10 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,19 %"},{"name":"f = 6 kHz 至 10 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,33 %"},{"name":"f = 10 kHz 至 20 kHz","range":"1 Ω to 10 Ω","cmc":"0,25 %"},{"name":"f = 10 kHz 至 20 kHz","range":"10 Ω to 100 Ω","cmc":"0,09 %"},{"name":"f = 10 kHz 至 20 kHz","range":"100 Ω to 10 kΩ","cmc":"0,07 %"},{"name":"f = 10 kHz 至 20 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,29 %"},{"name":"f = 10 kHz 至 20 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,53 %"},{"name":"f = 20 kHz 至 50 kHz","range":"1 Ω to 10 Ω","cmc":"0,37 %"},{"name":"f = 20 kHz 至 50 kHz","range":"10 Ω to 100 Ω","cmc":"0,13 %"},{"name":"f = 20 kHz 至 50 kHz","range":"100 Ω to 1 kΩ","cmc":"0,10 %"},{"name":"f = 20 kHz 至 50 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,12 %"},{"name":"f = 50 kHz 至 100 kHz","range":"1 Ω to 10 Ω","cmc":"0,77 %"},{"name":"f = 50 kHz 至 100 kHz","range":"10 Ω to 100 Ω","cmc":"0,26 %"},{"name":"f = 50 kHz 至 100 kHz","range":"100 Ω to 1 kΩ","cmc":"0,20 %"},{"name":"f = 50 kHz 至 100 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,23 %"}],"regulatory_area_zh":"交流电阻","search_zh":"标准电阻器 可调电阻器/十进电阻箱 标准电阻 分流器 RLC 电桥（测量仪） 阻抗电桥（测量仪） 电阻表 电气装置参数测量仪（测试仪） 故障回路阻抗测量仪 电子负载 校准 — 交流电阻 内部程序；在固定地点 (S) 及固定地点以外 (P) 交流电阻 内部程序 在固定地点 (S) 及固定地点以外 (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 100 Hz 至 1 kHz f = 100 Hz 至 1 kHz f = 100 Hz 至 1 kHz f = 100 Hz 至 1 kHz f = 100 Hz 至 1 kHz f = 100 Hz 至 1 kHz f = 100 Hz 至 1 kHz f = 1 kHz 至 3 kHz f = 1 kHz 至 3 kHz f = 1 kHz 至 3 kHz f = 1 kHz 至 3 kHz f = 1 kHz 至 3 kHz f = 1 kHz 至 3 kHz f = 1 kHz 至 3 kHz f = 3 kHz 至 6 kHz f = 3 kHz 至 6 kHz f = 3 kHz 至 6 kHz f = 3 kHz 至 6 kHz f = 3 kHz 至 6 kHz f = 3 kHz 至 6 kHz f = 3 kHz 至 6 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz LMEEiO/5 LMEEiO/14 LMEEiO/35 LMEEiO/53","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"标准电阻器\n可调电阻器/十进电阻箱\n标准电阻\n分流器\nRLC 电桥（测量仪）\n阻抗电桥（测量仪）\n电阻表\n电气装置参数测量仪（测试仪）\n故障回路阻抗测量仪\n电子负载","methodology_cs":"Kalibrace — Odpor AC","parameters_cs":[{"name":"f = 1 kHz","range":"0,001 Ω to 1 Ω","cmc":"0,08 %"},{"name":"f = 1 kHz","range":"1 Ω to 100 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"100 Ω to 1 MΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,12 %"},{"name":"f = 40 Hz až 100 Hz","range":"0,01 Ω to 1 Ω","cmc":"0,08 %"},{"name":"f = 40 Hz až 100 Hz","range":"1 Ω to 10 Ω","cmc":"0,07 %"},{"name":"f = 40 Hz až 100 Hz","range":"10 Ω to 100 Ω","cmc":"0,06 %"},{"name":"f = 40 Hz až 100 Hz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 40 Hz až 100 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,06 %"},{"name":"f = 40 Hz až 100 Hz","range":"100 kΩ to 1 MΩ","cmc":"0,09 %"},{"name":"f = 40 Hz až 100 Hz","range":"1 MΩ to 10 MΩ","cmc":"0,45 %"},{"name":"f = 100 Hz až 1 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,08 %"},{"name":"f = 100 Hz až 1 kHz","range":"1 Ω to 10 Ω","cmc":"0,05 %"},{"name":"f = 100 Hz až 1 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 100 Hz až 1 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 100 Hz až 1 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 100 Hz až 1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 100 Hz až 1 kHz","range":"1 Ω to 10 MΩ","cmc":"0,23 %"},{"name":"f = 1 kHz až 3 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,13 %"},{"name":"f = 1 kHz až 3 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 1 kHz až 3 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 1 kHz až 3 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 1 kHz až 3 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 1 kHz až 3 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 1 kHz až 3 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,23 %"},{"name":"f = 3 kHz až 6 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,23 %"},{"name":"f = 3 kHz až 6 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 3 kHz až 6 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 3 kHz až 6 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 3 kHz až 6 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,08 %"},{"name":"f = 3 kHz až 6 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,13 %"},{"name":"f = 3 kHz až 6 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,67 %"},{"name":"f = 6 kHz až 10 kHz","range":"0,01 Ω to 1 Ω","cmc":"0,23 %"},{"name":"f = 6 kHz až 10 kHz","range":"1 Ω to 10 Ω","cmc":"0,17 %"},{"name":"f = 6 kHz až 10 kHz","range":"10 Ω to 100 Ω","cmc":"0,07 %"},{"name":"f = 6 kHz až 10 kHz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 6 kHz až 10 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,19 %"},{"name":"f = 6 kHz až 10 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,33 %"},{"name":"f = 10 kHz až 20 kHz","range":"1 Ω to 10 Ω","cmc":"0,25 %"},{"name":"f = 10 kHz až 20 kHz","range":"10 Ω to 100 Ω","cmc":"0,09 %"},{"name":"f = 10 kHz až 20 kHz","range":"100 Ω to 10 kΩ","cmc":"0,07 %"},{"name":"f = 10 kHz až 20 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,29 %"},{"name":"f = 10 kHz až 20 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,53 %"},{"name":"f = 20 kHz až 50 kHz","range":"1 Ω to 10 Ω","cmc":"0,37 %"},{"name":"f = 20 kHz až 50 kHz","range":"10 Ω to 100 Ω","cmc":"0,13 %"},{"name":"f = 20 kHz až 50 kHz","range":"100 Ω to 1 kΩ","cmc":"0,10 %"},{"name":"f = 20 kHz až 50 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,12 %"},{"name":"f = 50 kHz až 100 kHz","range":"1 Ω to 10 Ω","cmc":"0,77 %"},{"name":"f = 50 kHz až 100 kHz","range":"10 Ω to 100 Ω","cmc":"0,26 %"},{"name":"f = 50 kHz až 100 kHz","range":"100 Ω to 1 kΩ","cmc":"0,20 %"},{"name":"f = 50 kHz až 100 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,23 %"}],"regulatory_area_cs":"Odpor AC","search_cs":"Etalonové rezistory Nastavitelné/dekádové rezistory Etalony odporu Bočníky Můstky (měřiče) RLC Můstky (měřiče) impedance Měřiče odporu Měřiče (testery) parametrů elektrických instalací Měřiče impedance smyčky Elektronické zátěže Kalibrace — Odpor AC Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Odpor AC Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 100 Hz až 1 kHz f = 100 Hz až 1 kHz f = 100 Hz až 1 kHz f = 100 Hz až 1 kHz f = 100 Hz až 1 kHz f = 100 Hz až 1 kHz f = 100 Hz až 1 kHz f = 1 kHz až 3 kHz f = 1 kHz až 3 kHz f = 1 kHz až 3 kHz f = 1 kHz až 3 kHz f = 1 kHz až 3 kHz f = 1 kHz až 3 kHz f = 1 kHz až 3 kHz f = 3 kHz až 6 kHz f = 3 kHz až 6 kHz f = 3 kHz až 6 kHz f = 3 kHz až 6 kHz f = 3 kHz až 6 kHz f = 3 kHz až 6 kHz f = 3 kHz až 6 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz LMEEiO/5 LMEEiO/14 LMEEiO/35 LMEEiO/53","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Etalonové rezistory\nNastavitelné/dekádové rezistory\nEtalony odporu\nBočníky\nMůstky (měřiče) RLC\nMůstky (měřiče) impedance\nMěřiče odporu\nMěřiče (testery) parametrů elektrických instalací\nMěřiče impedance smyčky\nElektronické zátěže"},{"_id":"16d06b488449fd62d1c5eeb6","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Wzorce impedancji","test_object_en":"Impedance standards","methodology":"Wzorcowanie — Impedancja","methodology_en":"Calibration — Impedance","parameters":[{"name":"f = 1 kHz","range":"1 Ω do 10 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"10 Ω do 100 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"100 Ω do 100 kΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"100 kΩ do 1 MΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"1 MΩ do 10 MΩ","cmc":"0,12 %"},{"name":"f = 1 kHz","range":"φ","cmc":"0,01 °"},{"name":"f = 40 Hz do 100 Hz","range":"0,1 Ω do 1 Ω","cmc":"0,21 %"},{"name":"f = 40 Hz do 100 Hz","range":"1 Ω do 10 Ω","cmc":"0,07 %"},{"name":"f = 40 Hz do 100 Hz","range":"10 Ω do 100 Ω","cmc":"0,06 %"},{"name":"f = 40 Hz do 100 Hz","range":"100 Ω do 10 kΩ","cmc":"0,05 %"},{"name":"f = 40 Hz do 100 Hz","range":"10 kΩ do 100 kΩ","cmc":"0,06 %"},{"name":"f = 40 Hz do 100 Hz","range":"100 kΩ do 1 MΩ","cmc":"0,09 %"},{"name":"f = 40 Hz do 100 Hz","range":"1 MΩ do 10 MΩ","cmc":"0,45 %"},{"name":"f = 40 Hz do 100 Hz","range":"φ","cmc":"0,04 °"},{"name":"f = 100 Hz do 250 Hz","range":"1 Ω do 10 Ω","cmc":"0,06 %"},{"name":"f = 100 Hz do 250 Hz","range":"10 Ω do 100 Ω","cmc":"0,05 %"},{"name":"f = 100 Hz do 250 Hz","range":"100 Ω do 10 kΩ","cmc":"0,04 %"},{"name":"f = 100 Hz do 250 Hz","range":"10 kΩ do 100 kΩ","cmc":"0,05 %"},{"name":"f = 100 Hz do 250 Hz","range":"100 kΩ do 1 MΩ","cmc":"0,07 %"},{"name":"f = 100 Hz do 250 Hz","range":"1 MΩ do 10 MΩ","cmc":"0,34 %"},{"name":"f = 100 Hz do 250 Hz","range":"φ","cmc":"0,03 °"},{"name":"f = 250 Hz do 1 kHz","range":"1 Ω do 10 Ω","cmc":"0,05 %"},{"name":"f = 250 Hz do 1 kHz","range":"10 Ω do 100 Ω","cmc":"0,04 %"},{"name":"f = 250 Hz do 1 kHz","range":"100 Ω do 10 kΩ","cmc":"0,03 %"},{"name":"f = 250 Hz do 1 kHz","range":"10 kΩ do 100 kΩ","cmc":"0,04 %"},{"name":"f = 250 Hz do 1 kHz","range":"100 kΩ do 1 MΩ","cmc":"0,05 %"},{"name":"f = 250 Hz do 1 kHz","range":"1 MΩ do 10 MΩ","cmc":"0,23 %"},{"name":"f = 250 Hz do 1 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 1 kHz do 3 kHz","range":"1 Ω do 10 Ω","cmc":"0,09 %"},{"name":"f = 1 kHz do 3 kHz","range":"10 Ω do 100 Ω","cmc":"0,04 %"},{"name":"f = 1 kHz do 3 kHz","range":"100 Ω do 10 kΩ","cmc":"0,03 %"},{"name":"f = 1 kHz do 3 kHz","range":"10 kΩ do 100 kΩ","cmc":"0,08 %"},{"name":"f = 1 kHz do 3 kHz","range":"100 kΩ do 1 MΩ","cmc":"0,13 %"},{"name":"f = 1 kHz do 3 kHz","range":"1 MΩ do 10 MΩ","cmc":"0,67 %"},{"name":"f = 1 kHz do 3 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 3 kHz do 6 kHz","range":"1 Ω do 10 Ω","cmc":"0,09 %"},{"name":"f = 3 kHz do 6 kHz","range":"10 Ω do 100 Ω","cmc":"0,04 %"},{"name":"f = 3 kHz do 6 kHz","range":"100 Ω do 10 kΩ","cmc":"0,03 %"},{"name":"f = 3 kHz do 6 kHz","range":"10 kΩ do 100 kΩ","cmc":"0,04 %"},{"name":"f = 3 kHz do 6 kHz","range":"100 kΩ do 1 MΩ","cmc":"0,05 %"},{"name":"f = 3 kHz do 6 kHz","range":"1 MΩ do 10 MΩ","cmc":"0,23 %"},{"name":"f = 3 kHz do 6 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 6 kHz do 10 kHz","range":"1 Ω do 10 Ω","cmc":"0,17 %"},{"name":"f = 6 kHz do 10 kHz","range":"10 Ω do 100 Ω","cmc":"0,07 %"},{"name":"f = 6 kHz do 10 kHz","range":"100 Ω do 10 kΩ","cmc":"0,05 %"},{"name":"f = 6 kHz do 10 kHz","range":"10 kΩ do 100 kΩ","cmc":"0,19 %"},{"name":"f = 6 kHz do 10 kHz","range":"100 kΩ do 1MΩ","cmc":"0,33 %"},{"name":"f = 6 kHz do 10 kHz","range":"φ","cmc":"0,04 °"},{"name":"f = 10 kHz do 20 kHz","range":"1 Ω do 10 Ω","cmc":"0,25 %"},{"name":"f = 10 kHz do 20 kHz","range":"10 Ω do 100 Ω","cmc":"0,09 %"},{"name":"f = 10 kHz do 20 kHz","range":"100 Ω do 10 kΩ","cmc":"0,07 %"},{"name":"f = 10 kHz do 20 kHz","range":"10 kΩ do 100 kΩ","cmc":"0,29 %"},{"name":"f = 10 kHz do 20 kHz","range":"100 kΩ do 1 MΩ","cmc":"0,53 %"},{"name":"f = 10 kHz do 20 kHz","range":"φ","cmc":"0,06 °"},{"name":"f = 20 kHz do 30 kHz","range":"1 Ω do 10 Ω","cmc":"0,37 %"},{"name":"f = 20 kHz do 30 kHz","range":"10 Ω do 100 Ω","cmc":"0,13 %"},{"name":"f = 20 kHz do 30 kHz","range":"100 Ω do 1 kΩ","cmc":"0,10 %"},{"name":"f = 20 kHz do 30 kHz","range":"1 kΩ do 10 kΩ","cmc":"0,12 %"},{"name":"f = 20 kHz do 30 kHz","range":"φ","cmc":"0,09 °"},{"name":"f = 50 kHz do 100 kHz","range":"1 Ω do 10 Ω","cmc":"0,77 %"},{"name":"f = 50 kHz do 100 kHz","range":"10 Ω do 100 Ω","cmc":"0,26 %"},{"name":"f = 50 kHz do 100 kHz","range":"100 Ω do 1 kΩ","cmc":"0,20 %"},{"name":"f = 50 kHz do 100 kHz","range":"1 kΩ do 10 kΩ","cmc":"0,23 %"},{"name":"f = 50 kHz do 100 kHz","range":"φ","cmc":"0,20 °"}],"parameters_en":[{"name":"f = 1 kHz","range":"1 Ω to 10 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"10 Ω to 100 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"100 Ω to 100 kΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,12 %"},{"name":"f = 1 kHz","range":"φ","cmc":"0,01 °"},{"name":"f = 40 Hz to 100 Hz","range":"0,1 Ω to 1 Ω","cmc":"0,21 %"},{"name":"f = 40 Hz to 100 Hz","range":"1 Ω to 10 Ω","cmc":"0,07 %"},{"name":"f = 40 Hz to 100 Hz","range":"10 Ω to 100 Ω","cmc":"0,06 %"},{"name":"f = 40 Hz to 100 Hz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 40 Hz to 100 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,06 %"},{"name":"f = 40 Hz to 100 Hz","range":"100 kΩ to 1 MΩ","cmc":"0,09 %"},{"name":"f = 40 Hz to 100 Hz","range":"1 MΩ to 10 MΩ","cmc":"0,45 %"},{"name":"f = 40 Hz to 100 Hz","range":"φ","cmc":"0,04 °"},{"name":"f = 100 Hz to 250 Hz","range":"1 Ω to 10 Ω","cmc":"0,06 %"},{"name":"f = 100 Hz to 250 Hz","range":"10 Ω to 100 Ω","cmc":"0,05 %"},{"name":"f = 100 Hz to 250 Hz","range":"100 Ω to 10 kΩ","cmc":"0,04 %"},{"name":"f = 100 Hz to 250 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,05 %"},{"name":"f = 100 Hz to 250 Hz","range":"100 kΩ to 1 MΩ","cmc":"0,07 %"},{"name":"f = 100 Hz to 250 Hz","range":"1 MΩ to 10 MΩ","cmc":"0,34 %"},{"name":"f = 100 Hz to 250 Hz","range":"φ","cmc":"0,03 °"},{"name":"f = 250 Hz to 1 kHz","range":"1 Ω to 10 Ω","cmc":"0,05 %"},{"name":"f = 250 Hz to 1 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 250 Hz to 1 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 250 Hz to 1 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 250 Hz to 1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 250 Hz to 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,23 %"},{"name":"f = 250 Hz to 1 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 1 kHz to 3 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 1 kHz to 3 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 1 kHz to 3 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 1 kHz to 3 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,08 %"},{"name":"f = 1 kHz to 3 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,13 %"},{"name":"f = 1 kHz to 3 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,67 %"},{"name":"f = 1 kHz to 3 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 3 kHz to 6 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 3 kHz to 6 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 3 kHz to 6 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 3 kHz to 6 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 3 kHz to 6 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 3 kHz to 6 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,23 %"},{"name":"f = 3 kHz to 6 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 6 kHz to 10 kHz","range":"1 Ω to 10 Ω","cmc":"0,17 %"},{"name":"f = 6 kHz to 10 kHz","range":"10 Ω to 100 Ω","cmc":"0,07 %"},{"name":"f = 6 kHz to 10 kHz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 6 kHz to 10 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,19 %"},{"name":"f = 6 kHz to 10 kHz","range":"100 kΩ to 1MΩ","cmc":"0,33 %"},{"name":"f = 6 kHz to 10 kHz","range":"φ","cmc":"0,04 °"},{"name":"f = 10 kHz to 20 kHz","range":"1 Ω to 10 Ω","cmc":"0,25 %"},{"name":"f = 10 kHz to 20 kHz","range":"10 Ω to 100 Ω","cmc":"0,09 %"},{"name":"f = 10 kHz to 20 kHz","range":"100 Ω to 10 kΩ","cmc":"0,07 %"},{"name":"f = 10 kHz to 20 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,29 %"},{"name":"f = 10 kHz to 20 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,53 %"},{"name":"f = 10 kHz to 20 kHz","range":"φ","cmc":"0,06 °"},{"name":"f = 20 kHz to 30 kHz","range":"1 Ω to 10 Ω","cmc":"0,37 %"},{"name":"f = 20 kHz to 30 kHz","range":"10 Ω to 100 Ω","cmc":"0,13 %"},{"name":"f = 20 kHz to 30 kHz","range":"100 Ω to 1 kΩ","cmc":"0,10 %"},{"name":"f = 20 kHz to 30 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,12 %"},{"name":"f = 20 kHz to 30 kHz","range":"φ","cmc":"0,09 °"},{"name":"f = 50 kHz to 100 kHz","range":"1 Ω to 10 Ω","cmc":"0,77 %"},{"name":"f = 50 kHz to 100 kHz","range":"10 Ω to 100 Ω","cmc":"0,26 %"},{"name":"f = 50 kHz to 100 kHz","range":"100 Ω to 1 kΩ","cmc":"0,20 %"},{"name":"f = 50 kHz to 100 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,23 %"},{"name":"f = 50 kHz to 100 kHz","range":"φ","cmc":"0,20 °"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia lub pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct or indirect method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia lub pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct or indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Impedancja\nZakres:\nf = 1 kHz 1 Ω do 10 Ω CMC 0,03 %\nf = 1 kHz 10 Ω do 100 Ω CMC 0,03 %\nf = 1 kHz 100 Ω do 100 kΩ CMC 0,02 %\nf = 1 kHz 100 kΩ do 1 MΩ CMC 0,02 %\nf = 1 kHz 1 MΩ do 10 MΩ CMC 0,12 %\nf = 1 kHz φ CMC 0,01 °\nf = 40 Hz do 100 Hz 0,1 Ω do 1 Ω CMC 0,21 %\nf = 40 Hz do 100 Hz 1 Ω do 10 Ω CMC 0,07 %\nf = 40 Hz do 100 Hz 10 Ω do 100 Ω CMC 0,06 %\nf = 40 Hz do 100 Hz 100 Ω do 10 kΩ CMC 0,05 %\nf = 40 Hz do 100 Hz 10 kΩ do 100 kΩ CMC 0,06 %\nf = 40 Hz do 100 Hz 100 kΩ do 1 MΩ CMC 0,09 %\nf = 40 Hz do 100 Hz 1 MΩ do 10 MΩ CMC 0,45 %\nf = 40 Hz do 100 Hz φ CMC 0,04 °\nf = 100 Hz do 250 Hz 1 Ω do 10 Ω CMC 0,06 %\nf = 100 Hz do 250 Hz 10 Ω do 100 Ω CMC 0,05 %\nf = 100 Hz do 250 Hz 100 Ω do 10 kΩ CMC 0,04 %\nf = 100 Hz do 250 Hz 10 kΩ do 100 kΩ CMC 0,05 %\nf = 100 Hz do 250 Hz 100 kΩ do 1 MΩ CMC 0,07 %\nf = 100 Hz do 250 Hz 1 MΩ do 10 MΩ CMC 0,34 %\nf = 100 Hz do 250 Hz φ CMC 0,03 °\nf = 250 Hz do 1 kHz 1 Ω do 10 Ω CMC 0,05 %\nf = 250 Hz do 1 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 250 Hz do 1 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 250 Hz do 1 kHz 10 kΩ do 100 kΩ CMC 0,04 %\nf = 250 Hz do 1 kHz 100 kΩ do 1 MΩ CMC 0,05 %\nf = 250 Hz do 1 kHz 1 MΩ do 10 MΩ CMC 0,23 %\nf = 250 Hz do 1 kHz φ CMC 0,02 °\nf = 1 kHz do 3 kHz 1 Ω do 10 Ω CMC 0,09 %\nf = 1 kHz do 3 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 1 kHz do 3 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 1 kHz do 3 kHz 10 kΩ do 100 kΩ CMC 0,08 %\nf = 1 kHz do 3 kHz 100 kΩ do 1 MΩ CMC 0,13 %\nf = 1 kHz do 3 kHz 1 MΩ do 10 MΩ CMC 0,67 %\nf = 1 kHz do 3 kHz φ CMC 0,02 °\nf = 3 kHz do 6 kHz 1 Ω do 10 Ω CMC 0,09 %\nf = 3 kHz do 6 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 3 kHz do 6 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 3 kHz do 6 kHz 10 kΩ do 100 kΩ CMC 0,04 %\nf = 3 kHz do 6 kHz 100 kΩ do 1 MΩ CMC 0,05 %\nf = 3 kHz do 6 kHz 1 MΩ do 10 MΩ CMC 0,23 %\nf = 3 kHz do 6 kHz φ CMC 0,02 °\nf = 6 kHz do 10 kHz 1 Ω do 10 Ω CMC 0,17 %\nf = 6 kHz do 10 kHz 10 Ω do 100 Ω CMC 0,07 %\nf = 6 kHz do 10 kHz 100 Ω do 10 kΩ CMC 0,05 %\nf = 6 kHz do 10 kHz 10 kΩ do 100 kΩ CMC 0,19 %\nf = 6 kHz do 10 kHz 100 kΩ do 1MΩ CMC 0,33 %\nf = 6 kHz do 10 kHz φ CMC 0,04 °\nf = 10 kHz do 20 kHz 1 Ω do 10 Ω CMC 0,25 %\nf = 10 kHz do 20 kHz 10 Ω do 100 Ω CMC 0,09 %\nf = 10 kHz do 20 kHz 100 Ω do 10 kΩ CMC 0,07 %\nf = 10 kHz do 20 kHz 10 kΩ do 100 kΩ CMC 0,29 %\nf = 10 kHz do 20 kHz 100 kΩ do 1 MΩ CMC 0,53 %\nf = 10 kHz do 20 kHz φ CMC 0,06 °\nf = 20 kHz do 30 kHz 1 Ω do 10 Ω CMC 0,37 %\nf = 20 kHz do 30 kHz 10 Ω do 100 Ω CMC 0,13 %\nf = 20 kHz do 30 kHz 100 Ω do 1 kΩ CMC 0,10 %\nf = 20 kHz do 30 kHz 1 kΩ do 10 kΩ CMC 0,12 %\nf = 20 kHz do 30 kHz φ CMC 0,09 °\nf = 50 kHz do 100 kHz 1 Ω do 10 Ω CMC 0,77 %\nf = 50 kHz do 100 kHz 10 Ω do 100 Ω CMC 0,26 %\nf = 50 kHz do 100 kHz 100 Ω do 1 kΩ CMC 0,20 %\nf = 50 kHz do 100 kHz 1 kΩ do 10 kΩ CMC 0,23 %\nf = 50 kHz do 100 kHz φ CMC 0,20 °\nProcedura wewnętrzna; Metoda bezpośrednia lub pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/14","norm_bases":["LMEEiO/14"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Impedancja","regulatory_area_en":"Impedance","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Wzorce impedancji Wzorcowanie — Impedancja\nZakres:\nf = 1 kHz 1 Ω do 10 Ω CMC 0,03 %\nf = 1 kHz 10 Ω do 100 Ω CMC 0,03 %\nf = 1 kHz 100 Ω do 100 kΩ CMC 0,02 %\nf = 1 kHz 100 kΩ do 1 MΩ CMC 0,02 %\nf = 1 kHz 1 MΩ do 10 MΩ CMC 0,12 %\nf = 1 kHz φ CMC 0,01 °\nf = 40 Hz do 100 Hz 0,1 Ω do 1 Ω CMC 0,21 %\nf = 40 Hz do 100 Hz 1 Ω do 10 Ω CMC 0,07 %\nf = 40 Hz do 100 Hz 10 Ω do 100 Ω CMC 0,06 %\nf = 40 Hz do 100 Hz 100 Ω do 10 kΩ CMC 0,05 %\nf = 40 Hz do 100 Hz 10 kΩ do 100 kΩ CMC 0,06 %\nf = 40 Hz do 100 Hz 100 kΩ do 1 MΩ CMC 0,09 %\nf = 40 Hz do 100 Hz 1 MΩ do 10 MΩ CMC 0,45 %\nf = 40 Hz do 100 Hz φ CMC 0,04 °\nf = 100 Hz do 250 Hz 1 Ω do 10 Ω CMC 0,06 %\nf = 100 Hz do 250 Hz 10 Ω do 100 Ω CMC 0,05 %\nf = 100 Hz do 250 Hz 100 Ω do 10 kΩ CMC 0,04 %\nf = 100 Hz do 250 Hz 10 kΩ do 100 kΩ CMC 0,05 %\nf = 100 Hz do 250 Hz 100 kΩ do 1 MΩ CMC 0,07 %\nf = 100 Hz do 250 Hz 1 MΩ do 10 MΩ CMC 0,34 %\nf = 100 Hz do 250 Hz φ CMC 0,03 °\nf = 250 Hz do 1 kHz 1 Ω do 10 Ω CMC 0,05 %\nf = 250 Hz do 1 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 250 Hz do 1 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 250 Hz do 1 kHz 10 kΩ do 100 kΩ CMC 0,04 %\nf = 250 Hz do 1 kHz 100 kΩ do 1 MΩ CMC 0,05 %\nf = 250 Hz do 1 kHz 1 MΩ do 10 MΩ CMC 0,23 %\nf = 250 Hz do 1 kHz φ CMC 0,02 °\nf = 1 kHz do 3 kHz 1 Ω do 10 Ω CMC 0,09 %\nf = 1 kHz do 3 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 1 kHz do 3 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 1 kHz do 3 kHz 10 kΩ do 100 kΩ CMC 0,08 %\nf = 1 kHz do 3 kHz 100 kΩ do 1 MΩ CMC 0,13 %\nf = 1 kHz do 3 kHz 1 MΩ do 10 MΩ CMC 0,67 %\nf = 1 kHz do 3 kHz φ CMC 0,02 °\nf = 3 kHz do 6 kHz 1 Ω do 10 Ω CMC 0,09 %\nf = 3 kHz do 6 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 3 kHz do 6 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 3 kHz do 6 kHz 10 kΩ do 100 kΩ CMC 0,04 %\nf = 3 kHz do 6 kHz 100 kΩ do 1 MΩ CMC 0,05 %\nf = 3 kHz do 6 kHz 1 MΩ do 10 MΩ CMC 0,23 %\nf = 3 kHz do 6 kHz φ CMC 0,02 °\nf = 6 kHz do 10 kHz 1 Ω do 10 Ω CMC 0,17 %\nf = 6 kHz do 10 kHz 10 Ω do 100 Ω CMC 0,07 %\nf = 6 kHz do 10 kHz 100 Ω do 10 kΩ CMC 0,05 %\nf = 6 kHz do 10 kHz 10 kΩ do 100 kΩ CMC 0,19 %\nf = 6 kHz do 10 kHz 100 kΩ do 1MΩ CMC 0,33 %\nf = 6 kHz do 10 kHz φ CMC 0,04 °\nf = 10 kHz do 20 kHz 1 Ω do 10 Ω CMC 0,25 %\nf = 10 kHz do 20 kHz 10 Ω do 100 Ω CMC 0,09 %\nf = 10 kHz do 20 kHz 100 Ω do 10 kΩ CMC 0,07 %\nf = 10 kHz do 20 kHz 10 kΩ do 100 kΩ CMC 0,29 %\nf = 10 kHz do 20 kHz 100 kΩ do 1 MΩ CMC 0,53 %\nf = 10 kHz do 20 kHz φ CMC 0,06 °\nf = 20 kHz do 30 kHz 1 Ω do 10 Ω CMC 0,37 %\nf = 20 kHz do 30 kHz 10 Ω do 100 Ω CMC 0,13 %\nf = 20 kHz do 30 kHz 100 Ω do 1 kΩ CMC 0,10 %\nf = 20 kHz do 30 kHz 1 kΩ do 10 kΩ CMC 0,12 %\nf = 20 kHz do 30 kHz φ CMC 0,09 °\nf = 50 kHz do 100 kHz 1 Ω do 10 Ω CMC 0,77 %\nf = 50 kHz do 100 kHz 10 Ω do 100 Ω CMC 0,26 %\nf = 50 kHz do 100 kHz 100 Ω do 1 kΩ CMC 0,20 %\nf = 50 kHz do 100 kHz 1 kΩ do 10 kΩ CMC 0,23 %\nf = 50 kHz do 100 kHz φ CMC 0,20 °\nProcedura wewnętrzna; Metoda bezpośrednia lub pośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/14 Wzorce impedancji Wzorcowanie — Impedancja\nZakres:\nf = 1 kHz 1 Ω do 10 Ω CMC 0,03 %\nf = 1 kHz 10 Ω do 100 Ω CMC 0,03 %\nf = 1 kHz 100 Ω do 100 kΩ CMC 0,02 %\nf = 1 kHz 100 kΩ do 1 MΩ CMC 0,02 %\nf = 1 kHz 1 MΩ do 10 MΩ CMC 0,12 %\nf = 1 kHz φ CMC 0,01 °\nf = 40 Hz do 100 Hz 0,1 Ω do 1 Ω CMC 0,21 %\nf = 40 Hz do 100 Hz 1 Ω do 10 Ω CMC 0,07 %\nf = 40 Hz do 100 Hz 10 Ω do 100 Ω CMC 0,06 %\nf = 40 Hz do 100 Hz 100 Ω do 10 kΩ CMC 0,05 %\nf = 40 Hz do 100 Hz 10 kΩ do 100 kΩ CMC 0,06 %\nf = 40 Hz do 100 Hz 100 kΩ do 1 MΩ CMC 0,09 %\nf = 40 Hz do 100 Hz 1 MΩ do 10 MΩ CMC 0,45 %\nf = 40 Hz do 100 Hz φ CMC 0,04 °\nf = 100 Hz do 250 Hz 1 Ω do 10 Ω CMC 0,06 %\nf = 100 Hz do 250 Hz 10 Ω do 100 Ω CMC 0,05 %\nf = 100 Hz do 250 Hz 100 Ω do 10 kΩ CMC 0,04 %\nf = 100 Hz do 250 Hz 10 kΩ do 100 kΩ CMC 0,05 %\nf = 100 Hz do 250 Hz 100 kΩ do 1 MΩ CMC 0,07 %\nf = 100 Hz do 250 Hz 1 MΩ do 10 MΩ CMC 0,34 %\nf = 100 Hz do 250 Hz φ CMC 0,03 °\nf = 250 Hz do 1 kHz 1 Ω do 10 Ω CMC 0,05 %\nf = 250 Hz do 1 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 250 Hz do 1 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 250 Hz do 1 kHz 10 kΩ do 100 kΩ CMC 0,04 %\nf = 250 Hz do 1 kHz 100 kΩ do 1 MΩ CMC 0,05 %\nf = 250 Hz do 1 kHz 1 MΩ do 10 MΩ CMC 0,23 %\nf = 250 Hz do 1 kHz φ CMC 0,02 °\nf = 1 kHz do 3 kHz 1 Ω do 10 Ω CMC 0,09 %\nf = 1 kHz do 3 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 1 kHz do 3 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 1 kHz do 3 kHz 10 kΩ do 100 kΩ CMC 0,08 %\nf = 1 kHz do 3 kHz 100 kΩ do 1 MΩ CMC 0,13 %\nf = 1 kHz do 3 kHz 1 MΩ do 10 MΩ CMC 0,67 %\nf = 1 kHz do 3 kHz φ CMC 0,02 °\nf = 3 kHz do 6 kHz 1 Ω do 10 Ω CMC 0,09 %\nf = 3 kHz do 6 kHz 10 Ω do 100 Ω CMC 0,04 %\nf = 3 kHz do 6 kHz 100 Ω do 10 kΩ CMC 0,03 %\nf = 3 kHz do 6 kHz 10 kΩ do 100 kΩ CMC 0,04 %\nf = 3 kHz do 6 kHz 100 kΩ do 1 MΩ CMC 0,05 %\nf = 3 kHz do 6 kHz 1 MΩ do 10 MΩ CMC 0,23 %\nf = 3 kHz do 6 kHz φ CMC 0,02 °\nf = 6 kHz do 10 kHz 1 Ω do 10 Ω CMC 0,17 %\nf = 6 kHz do 10 kHz 10 Ω do 100 Ω CMC 0,07 %\nf = 6 kHz do 10 kHz 100 Ω do 10 kΩ CMC 0,05 %\nf = 6 kHz do 10 kHz 10 kΩ do 100 kΩ CMC 0,19 %\nf = 6 kHz do 10 kHz 100 kΩ do 1MΩ CMC 0,33 %\nf = 6 kHz do 10 kHz φ CMC 0,04 °\nf = 10 kHz do 20 kHz 1 Ω do 10 Ω CMC 0,25 %\nf = 10 kHz do 20 kHz 10 Ω do 100 Ω CMC 0,09 %\nf = 10 kHz do 20 kHz 100 Ω do 10 kΩ CMC 0,07 %\nf = 10 kHz do 20 kHz 10 kΩ do 100 kΩ CMC 0,29 %\nf = 10 kHz do 20 kHz 100 kΩ do 1 MΩ CMC 0,53 %\nf = 10 kHz do 20 kHz φ CMC 0,06 °\nf = 20 kHz do 30 kHz 1 Ω do 10 Ω CMC 0,37 %\nf = 20 kHz do 30 kHz 10 Ω do 100 Ω CMC 0,13 %\nf = 20 kHz do 30 kHz 100 Ω do 1 kΩ CMC 0,10 %\nf = 20 kHz do 30 kHz 1 kΩ do 10 kΩ CMC 0,12 %\nf = 20 kHz do 30 kHz φ CMC 0,09 °\nf = 50 kHz do 100 kHz 1 Ω do 10 Ω CMC 0,77 %\nf = 50 kHz do 100 kHz 10 Ω do 100 Ω CMC 0,26 %\nf = 50 kHz do 100 kHz 100 Ω do 1 kΩ CMC 0,20 %\nf = 50 kHz do 100 kHz 1 kΩ do 10 kΩ CMC 0,23 %\nf = 50 kHz do 100 kHz φ CMC 0,20 °\nProcedura wewnetrzna; Metoda bezposrednia lub posrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/14","search_en":"Impedance standards Calibration — Impedance Internal procedure; Direct or indirect method; At permanent location (S) and outside of it (P) Impedance Internal procedure Direct or indirect method At permanent location (S) and outside of it (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 40 Hz to 100 Hz f = 100 Hz to 250 Hz f = 100 Hz to 250 Hz f = 100 Hz to 250 Hz f = 100 Hz to 250 Hz f = 100 Hz to 250 Hz f = 100 Hz to 250 Hz f = 100 Hz to 250 Hz f = 250 Hz to 1 kHz f = 250 Hz to 1 kHz f = 250 Hz to 1 kHz f = 250 Hz to 1 kHz f = 250 Hz to 1 kHz f = 250 Hz to 1 kHz f = 250 Hz to 1 kHz f = 1 kHz to 3 kHz f = 1 kHz to 3 kHz f = 1 kHz to 3 kHz f = 1 kHz to 3 kHz f = 1 kHz to 3 kHz f = 1 kHz to 3 kHz f = 1 kHz to 3 kHz f = 3 kHz to 6 kHz f = 3 kHz to 6 kHz f = 3 kHz to 6 kHz f = 3 kHz to 6 kHz f = 3 kHz to 6 kHz f = 3 kHz to 6 kHz f = 3 kHz to 6 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 20 kHz to 30 kHz f = 20 kHz to 30 kHz f = 20 kHz to 30 kHz f = 20 kHz to 30 kHz f = 20 kHz to 30 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz LMEEiO/14","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":22,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Impedanz","parameters_de":[{"name":"f = 1 kHz","range":"1 Ω to 10 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"10 Ω to 100 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"100 Ω to 100 kΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,12 %"},{"name":"f = 1 kHz","range":"φ","cmc":"0,01 °"},{"name":"f = 40 Hz bis 100 Hz","range":"0,1 Ω to 1 Ω","cmc":"0,21 %"},{"name":"f = 40 Hz bis 100 Hz","range":"1 Ω to 10 Ω","cmc":"0,07 %"},{"name":"f = 40 Hz bis 100 Hz","range":"10 Ω to 100 Ω","cmc":"0,06 %"},{"name":"f = 40 Hz bis 100 Hz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 40 Hz bis 100 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,06 %"},{"name":"f = 40 Hz bis 100 Hz","range":"100 kΩ to 1 MΩ","cmc":"0,09 %"},{"name":"f = 40 Hz bis 100 Hz","range":"1 MΩ to 10 MΩ","cmc":"0,45 %"},{"name":"f = 40 Hz bis 100 Hz","range":"φ","cmc":"0,04 °"},{"name":"f = 100 Hz bis 250 Hz","range":"1 Ω to 10 Ω","cmc":"0,06 %"},{"name":"f = 100 Hz bis 250 Hz","range":"10 Ω to 100 Ω","cmc":"0,05 %"},{"name":"f = 100 Hz bis 250 Hz","range":"100 Ω to 10 kΩ","cmc":"0,04 %"},{"name":"f = 100 Hz bis 250 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,05 %"},{"name":"f = 100 Hz bis 250 Hz","range":"100 kΩ to 1 MΩ","cmc":"0,07 %"},{"name":"f = 100 Hz bis 250 Hz","range":"1 MΩ to 10 MΩ","cmc":"0,34 %"},{"name":"f = 100 Hz bis 250 Hz","range":"φ","cmc":"0,03 °"},{"name":"f = 250 Hz bis 1 kHz","range":"1 Ω to 10 Ω","cmc":"0,05 %"},{"name":"f = 250 Hz bis 1 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 250 Hz bis 1 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 250 Hz bis 1 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 250 Hz bis 1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 250 Hz bis 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,23 %"},{"name":"f = 250 Hz bis 1 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 1 kHz bis 3 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 1 kHz bis 3 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 1 kHz bis 3 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 1 kHz bis 3 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,08 %"},{"name":"f = 1 kHz bis 3 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,13 %"},{"name":"f = 1 kHz bis 3 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,67 %"},{"name":"f = 1 kHz bis 3 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 3 kHz bis 6 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 3 kHz bis 6 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 3 kHz bis 6 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 3 kHz bis 6 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 3 kHz bis 6 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 3 kHz bis 6 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,23 %"},{"name":"f = 3 kHz bis 6 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 6 kHz bis 10 kHz","range":"1 Ω to 10 Ω","cmc":"0,17 %"},{"name":"f = 6 kHz bis 10 kHz","range":"10 Ω to 100 Ω","cmc":"0,07 %"},{"name":"f = 6 kHz bis 10 kHz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 6 kHz bis 10 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,19 %"},{"name":"f = 6 kHz bis 10 kHz","range":"100 kΩ to 1MΩ","cmc":"0,33 %"},{"name":"f = 6 kHz bis 10 kHz","range":"φ","cmc":"0,04 °"},{"name":"f = 10 kHz bis 20 kHz","range":"1 Ω to 10 Ω","cmc":"0,25 %"},{"name":"f = 10 kHz bis 20 kHz","range":"10 Ω to 100 Ω","cmc":"0,09 %"},{"name":"f = 10 kHz bis 20 kHz","range":"100 Ω to 10 kΩ","cmc":"0,07 %"},{"name":"f = 10 kHz bis 20 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,29 %"},{"name":"f = 10 kHz bis 20 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,53 %"},{"name":"f = 10 kHz bis 20 kHz","range":"φ","cmc":"0,06 °"},{"name":"f = 20 kHz bis 30 kHz","range":"1 Ω to 10 Ω","cmc":"0,37 %"},{"name":"f = 20 kHz bis 30 kHz","range":"10 Ω to 100 Ω","cmc":"0,13 %"},{"name":"f = 20 kHz bis 30 kHz","range":"100 Ω to 1 kΩ","cmc":"0,10 %"},{"name":"f = 20 kHz bis 30 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,12 %"},{"name":"f = 20 kHz bis 30 kHz","range":"φ","cmc":"0,09 °"},{"name":"f = 50 kHz bis 100 kHz","range":"1 Ω to 10 Ω","cmc":"0,77 %"},{"name":"f = 50 kHz bis 100 kHz","range":"10 Ω to 100 Ω","cmc":"0,26 %"},{"name":"f = 50 kHz bis 100 kHz","range":"100 Ω to 1 kΩ","cmc":"0,20 %"},{"name":"f = 50 kHz bis 100 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,23 %"},{"name":"f = 50 kHz bis 100 kHz","range":"φ","cmc":"0,20 °"}],"regulatory_area_de":"Impedanz","search_de":"Impedanznormale Kalibrierung — Impedanz Internes Verfahren; Direktes oder indirektes Verfahren; Am festen Standort (S) und außerhalb (P) Impedanz Internes Verfahren Direktes oder indirektes Verfahren Am festen Standort (S) und außerhalb (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 40 Hz bis 100 Hz f = 100 Hz bis 250 Hz f = 100 Hz bis 250 Hz f = 100 Hz bis 250 Hz f = 100 Hz bis 250 Hz f = 100 Hz bis 250 Hz f = 100 Hz bis 250 Hz f = 100 Hz bis 250 Hz f = 250 Hz bis 1 kHz f = 250 Hz bis 1 kHz f = 250 Hz bis 1 kHz f = 250 Hz bis 1 kHz f = 250 Hz bis 1 kHz f = 250 Hz bis 1 kHz f = 250 Hz bis 1 kHz f = 1 kHz bis 3 kHz f = 1 kHz bis 3 kHz f = 1 kHz bis 3 kHz f = 1 kHz bis 3 kHz f = 1 kHz bis 3 kHz f = 1 kHz bis 3 kHz f = 1 kHz bis 3 kHz f = 3 kHz bis 6 kHz f = 3 kHz bis 6 kHz f = 3 kHz bis 6 kHz f = 3 kHz bis 6 kHz f = 3 kHz bis 6 kHz f = 3 kHz bis 6 kHz f = 3 kHz bis 6 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 20 kHz bis 30 kHz f = 20 kHz bis 30 kHz f = 20 kHz bis 30 kHz f = 20 kHz bis 30 kHz f = 20 kHz bis 30 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz LMEEiO/14","technique_de":"Internes Verfahren; Direktes oder indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes oder indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Impedanznormale","methodology_zh":"校准 — 阻抗","parameters_zh":[{"name":"f = 1 kHz","range":"1 Ω to 10 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"10 Ω to 100 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"100 Ω to 100 kΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,12 %"},{"name":"f = 1 kHz","range":"φ","cmc":"0,01 °"},{"name":"f = 40 Hz 至 100 Hz","range":"0,1 Ω to 1 Ω","cmc":"0,21 %"},{"name":"f = 40 Hz 至 100 Hz","range":"1 Ω to 10 Ω","cmc":"0,07 %"},{"name":"f = 40 Hz 至 100 Hz","range":"10 Ω to 100 Ω","cmc":"0,06 %"},{"name":"f = 40 Hz 至 100 Hz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 40 Hz 至 100 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,06 %"},{"name":"f = 40 Hz 至 100 Hz","range":"100 kΩ to 1 MΩ","cmc":"0,09 %"},{"name":"f = 40 Hz 至 100 Hz","range":"1 MΩ to 10 MΩ","cmc":"0,45 %"},{"name":"f = 40 Hz 至 100 Hz","range":"φ","cmc":"0,04 °"},{"name":"f = 100 Hz 至 250 Hz","range":"1 Ω to 10 Ω","cmc":"0,06 %"},{"name":"f = 100 Hz 至 250 Hz","range":"10 Ω to 100 Ω","cmc":"0,05 %"},{"name":"f = 100 Hz 至 250 Hz","range":"100 Ω to 10 kΩ","cmc":"0,04 %"},{"name":"f = 100 Hz 至 250 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,05 %"},{"name":"f = 100 Hz 至 250 Hz","range":"100 kΩ to 1 MΩ","cmc":"0,07 %"},{"name":"f = 100 Hz 至 250 Hz","range":"1 MΩ to 10 MΩ","cmc":"0,34 %"},{"name":"f = 100 Hz 至 250 Hz","range":"φ","cmc":"0,03 °"},{"name":"f = 250 Hz 至 1 kHz","range":"1 Ω to 10 Ω","cmc":"0,05 %"},{"name":"f = 250 Hz 至 1 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 250 Hz 至 1 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 250 Hz 至 1 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 250 Hz 至 1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 250 Hz 至 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,23 %"},{"name":"f = 250 Hz 至 1 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 1 kHz 至 3 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 1 kHz 至 3 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 1 kHz 至 3 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 1 kHz 至 3 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,08 %"},{"name":"f = 1 kHz 至 3 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,13 %"},{"name":"f = 1 kHz 至 3 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,67 %"},{"name":"f = 1 kHz 至 3 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 3 kHz 至 6 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 3 kHz 至 6 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 3 kHz 至 6 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 3 kHz 至 6 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 3 kHz 至 6 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 3 kHz 至 6 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,23 %"},{"name":"f = 3 kHz 至 6 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 6 kHz 至 10 kHz","range":"1 Ω to 10 Ω","cmc":"0,17 %"},{"name":"f = 6 kHz 至 10 kHz","range":"10 Ω to 100 Ω","cmc":"0,07 %"},{"name":"f = 6 kHz 至 10 kHz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 6 kHz 至 10 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,19 %"},{"name":"f = 6 kHz 至 10 kHz","range":"100 kΩ to 1MΩ","cmc":"0,33 %"},{"name":"f = 6 kHz 至 10 kHz","range":"φ","cmc":"0,04 °"},{"name":"f = 10 kHz 至 20 kHz","range":"1 Ω to 10 Ω","cmc":"0,25 %"},{"name":"f = 10 kHz 至 20 kHz","range":"10 Ω to 100 Ω","cmc":"0,09 %"},{"name":"f = 10 kHz 至 20 kHz","range":"100 Ω to 10 kΩ","cmc":"0,07 %"},{"name":"f = 10 kHz 至 20 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,29 %"},{"name":"f = 10 kHz 至 20 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,53 %"},{"name":"f = 10 kHz 至 20 kHz","range":"φ","cmc":"0,06 °"},{"name":"f = 20 kHz 至 30 kHz","range":"1 Ω to 10 Ω","cmc":"0,37 %"},{"name":"f = 20 kHz 至 30 kHz","range":"10 Ω to 100 Ω","cmc":"0,13 %"},{"name":"f = 20 kHz 至 30 kHz","range":"100 Ω to 1 kΩ","cmc":"0,10 %"},{"name":"f = 20 kHz 至 30 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,12 %"},{"name":"f = 20 kHz 至 30 kHz","range":"φ","cmc":"0,09 °"},{"name":"f = 50 kHz 至 100 kHz","range":"1 Ω to 10 Ω","cmc":"0,77 %"},{"name":"f = 50 kHz 至 100 kHz","range":"10 Ω to 100 Ω","cmc":"0,26 %"},{"name":"f = 50 kHz 至 100 kHz","range":"100 Ω to 1 kΩ","cmc":"0,20 %"},{"name":"f = 50 kHz 至 100 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,23 %"},{"name":"f = 50 kHz 至 100 kHz","range":"φ","cmc":"0,20 °"}],"regulatory_area_zh":"阻抗","search_zh":"标准阻抗 校准 — 阻抗 内部程序; 直接法或间接法; 在固定地点 (S) 及固定地点以外 (P) 阻抗 内部程序 直接法或间接法 在固定地点 (S) 及固定地点以外 (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 40 Hz 至 100 Hz f = 100 Hz 至 250 Hz f = 100 Hz 至 250 Hz f = 100 Hz 至 250 Hz f = 100 Hz 至 250 Hz f = 100 Hz 至 250 Hz f = 100 Hz 至 250 Hz f = 100 Hz 至 250 Hz f = 250 Hz 至 1 kHz f = 250 Hz 至 1 kHz f = 250 Hz 至 1 kHz f = 250 Hz 至 1 kHz f = 250 Hz 至 1 kHz f = 250 Hz 至 1 kHz f = 250 Hz 至 1 kHz f = 1 kHz 至 3 kHz f = 1 kHz 至 3 kHz f = 1 kHz 至 3 kHz f = 1 kHz 至 3 kHz f = 1 kHz 至 3 kHz f = 1 kHz 至 3 kHz f = 1 kHz 至 3 kHz f = 3 kHz 至 6 kHz f = 3 kHz 至 6 kHz f = 3 kHz 至 6 kHz f = 3 kHz 至 6 kHz f = 3 kHz 至 6 kHz f = 3 kHz 至 6 kHz f = 3 kHz 至 6 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 20 kHz 至 30 kHz f = 20 kHz 至 30 kHz f = 20 kHz 至 30 kHz f = 20 kHz 至 30 kHz f = 20 kHz 至 30 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz LMEEiO/14","technique_zh":"内部程序; 直接法或间接法; 在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法或间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"标准阻抗","methodology_cs":"Kalibrace — Impedance","parameters_cs":[{"name":"f = 1 kHz","range":"1 Ω to 10 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"10 Ω to 100 Ω","cmc":"0,03 %"},{"name":"f = 1 kHz","range":"100 Ω to 100 kΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,12 %"},{"name":"f = 1 kHz","range":"φ","cmc":"0,01 °"},{"name":"f = 40 Hz až 100 Hz","range":"0,1 Ω to 1 Ω","cmc":"0,21 %"},{"name":"f = 40 Hz až 100 Hz","range":"1 Ω to 10 Ω","cmc":"0,07 %"},{"name":"f = 40 Hz až 100 Hz","range":"10 Ω to 100 Ω","cmc":"0,06 %"},{"name":"f = 40 Hz až 100 Hz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 40 Hz až 100 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,06 %"},{"name":"f = 40 Hz až 100 Hz","range":"100 kΩ to 1 MΩ","cmc":"0,09 %"},{"name":"f = 40 Hz až 100 Hz","range":"1 MΩ to 10 MΩ","cmc":"0,45 %"},{"name":"f = 40 Hz až 100 Hz","range":"φ","cmc":"0,04 °"},{"name":"f = 100 Hz až 250 Hz","range":"1 Ω to 10 Ω","cmc":"0,06 %"},{"name":"f = 100 Hz až 250 Hz","range":"10 Ω to 100 Ω","cmc":"0,05 %"},{"name":"f = 100 Hz až 250 Hz","range":"100 Ω to 10 kΩ","cmc":"0,04 %"},{"name":"f = 100 Hz až 250 Hz","range":"10 kΩ to 100 kΩ","cmc":"0,05 %"},{"name":"f = 100 Hz až 250 Hz","range":"100 kΩ to 1 MΩ","cmc":"0,07 %"},{"name":"f = 100 Hz až 250 Hz","range":"1 MΩ to 10 MΩ","cmc":"0,34 %"},{"name":"f = 100 Hz až 250 Hz","range":"φ","cmc":"0,03 °"},{"name":"f = 250 Hz až 1 kHz","range":"1 Ω to 10 Ω","cmc":"0,05 %"},{"name":"f = 250 Hz až 1 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 250 Hz až 1 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 250 Hz až 1 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 250 Hz až 1 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 250 Hz až 1 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,23 %"},{"name":"f = 250 Hz až 1 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 1 kHz až 3 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 1 kHz až 3 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 1 kHz až 3 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 1 kHz až 3 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,08 %"},{"name":"f = 1 kHz až 3 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,13 %"},{"name":"f = 1 kHz až 3 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,67 %"},{"name":"f = 1 kHz až 3 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 3 kHz až 6 kHz","range":"1 Ω to 10 Ω","cmc":"0,09 %"},{"name":"f = 3 kHz až 6 kHz","range":"10 Ω to 100 Ω","cmc":"0,04 %"},{"name":"f = 3 kHz až 6 kHz","range":"100 Ω to 10 kΩ","cmc":"0,03 %"},{"name":"f = 3 kHz až 6 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,04 %"},{"name":"f = 3 kHz až 6 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,05 %"},{"name":"f = 3 kHz až 6 kHz","range":"1 MΩ to 10 MΩ","cmc":"0,23 %"},{"name":"f = 3 kHz až 6 kHz","range":"φ","cmc":"0,02 °"},{"name":"f = 6 kHz až 10 kHz","range":"1 Ω to 10 Ω","cmc":"0,17 %"},{"name":"f = 6 kHz až 10 kHz","range":"10 Ω to 100 Ω","cmc":"0,07 %"},{"name":"f = 6 kHz až 10 kHz","range":"100 Ω to 10 kΩ","cmc":"0,05 %"},{"name":"f = 6 kHz až 10 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,19 %"},{"name":"f = 6 kHz až 10 kHz","range":"100 kΩ to 1MΩ","cmc":"0,33 %"},{"name":"f = 6 kHz až 10 kHz","range":"φ","cmc":"0,04 °"},{"name":"f = 10 kHz až 20 kHz","range":"1 Ω to 10 Ω","cmc":"0,25 %"},{"name":"f = 10 kHz až 20 kHz","range":"10 Ω to 100 Ω","cmc":"0,09 %"},{"name":"f = 10 kHz až 20 kHz","range":"100 Ω to 10 kΩ","cmc":"0,07 %"},{"name":"f = 10 kHz až 20 kHz","range":"10 kΩ to 100 kΩ","cmc":"0,29 %"},{"name":"f = 10 kHz až 20 kHz","range":"100 kΩ to 1 MΩ","cmc":"0,53 %"},{"name":"f = 10 kHz až 20 kHz","range":"φ","cmc":"0,06 °"},{"name":"f = 20 kHz až 30 kHz","range":"1 Ω to 10 Ω","cmc":"0,37 %"},{"name":"f = 20 kHz až 30 kHz","range":"10 Ω to 100 Ω","cmc":"0,13 %"},{"name":"f = 20 kHz až 30 kHz","range":"100 Ω to 1 kΩ","cmc":"0,10 %"},{"name":"f = 20 kHz až 30 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,12 %"},{"name":"f = 20 kHz až 30 kHz","range":"φ","cmc":"0,09 °"},{"name":"f = 50 kHz až 100 kHz","range":"1 Ω to 10 Ω","cmc":"0,77 %"},{"name":"f = 50 kHz až 100 kHz","range":"10 Ω to 100 Ω","cmc":"0,26 %"},{"name":"f = 50 kHz až 100 kHz","range":"100 Ω to 1 kΩ","cmc":"0,20 %"},{"name":"f = 50 kHz až 100 kHz","range":"1 kΩ to 10 kΩ","cmc":"0,23 %"},{"name":"f = 50 kHz až 100 kHz","range":"φ","cmc":"0,20 °"}],"regulatory_area_cs":"Impedance","search_cs":"Etalony impedance Kalibrace — Impedance Vnitřní postup; Přímá nebo nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P) Impedance Vnitřní postup Přímá nebo nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 40 Hz až 100 Hz f = 100 Hz až 250 Hz f = 100 Hz až 250 Hz f = 100 Hz až 250 Hz f = 100 Hz až 250 Hz f = 100 Hz až 250 Hz f = 100 Hz až 250 Hz f = 100 Hz až 250 Hz f = 250 Hz až 1 kHz f = 250 Hz až 1 kHz f = 250 Hz až 1 kHz f = 250 Hz až 1 kHz f = 250 Hz až 1 kHz f = 250 Hz až 1 kHz f = 250 Hz až 1 kHz f = 1 kHz až 3 kHz f = 1 kHz až 3 kHz f = 1 kHz až 3 kHz f = 1 kHz až 3 kHz f = 1 kHz až 3 kHz f = 1 kHz až 3 kHz f = 1 kHz až 3 kHz f = 3 kHz až 6 kHz f = 3 kHz až 6 kHz f = 3 kHz až 6 kHz f = 3 kHz až 6 kHz f = 3 kHz až 6 kHz f = 3 kHz až 6 kHz f = 3 kHz až 6 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 20 kHz až 30 kHz f = 20 kHz až 30 kHz f = 20 kHz až 30 kHz f = 20 kHz až 30 kHz f = 20 kHz až 30 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz LMEEiO/14","technique_cs":"Vnitřní postup; Přímá nebo nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá nebo nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Etalony impedance"},{"_id":"a09153f84047371a658ab757","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki impedancji\nMostki","test_object_en":"Impedance meters\nBridges","methodology":"Wzorcowanie — Impedancja","methodology_en":"Calibration — Impedance","parameters":[{"name":"f = 1 kHz","range":"90 Ω do 900 kΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"φ","cmc":"0,01 °"},{"name":"f = 100 kHz","range":"9 Ω do 9 kΩ","cmc":"0,2 %"},{"name":"f = 100 kHz","range":"φ","cmc":"0,2 °"}],"parameters_en":[{"name":"f = 1 kHz","range":"90 Ω to 900 kΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"φ","cmc":"0,01 °"},{"name":"f = 100 kHz","range":"9 Ω to 9 kΩ","cmc":"0,2 %"},{"name":"f = 100 kHz","range":"φ","cmc":"0,2 °"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Impedancja\nZakres:\nf = 1 kHz 90 Ω do 900 kΩ CMC 0,02 %\nf = 1 kHz φ CMC 0,01 °\nf = 100 kHz 9 Ω do 9 kΩ CMC 0,2 %\nf = 100 kHz φ CMC 0,2 °\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/5","norm_bases":["LMEEiO/5"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Impedancja","regulatory_area_en":"Impedance","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki impedancji\nMostki Wzorcowanie — Impedancja\nZakres:\nf = 1 kHz 90 Ω do 900 kΩ CMC 0,02 %\nf = 1 kHz φ CMC 0,01 °\nf = 100 kHz 9 Ω do 9 kΩ CMC 0,2 %\nf = 100 kHz φ CMC 0,2 °\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/5 Mierniki impedancji\nMostki Wzorcowanie — Impedancja\nZakres:\nf = 1 kHz 90 Ω do 900 kΩ CMC 0,02 %\nf = 1 kHz φ CMC 0,01 °\nf = 100 kHz 9 Ω do 9 kΩ CMC 0,2 %\nf = 100 kHz φ CMC 0,2 °\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/5","search_en":"Impedance meters Bridges Calibration — Impedance Internal procedure; Direct method; At permanent location (S) and outside of it (P) Impedance Internal procedure Direct method At permanent location (S) and outside of it (P) f = 1 kHz f = 1 kHz f = 100 kHz f = 100 kHz LMEEiO/5","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":23,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Impedanz","parameters_de":[{"name":"f = 1 kHz","range":"90 Ω to 900 kΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"φ","cmc":"0,01 °"},{"name":"f = 100 kHz","range":"9 Ω to 9 kΩ","cmc":"0,2 %"},{"name":"f = 100 kHz","range":"φ","cmc":"0,2 °"}],"regulatory_area_de":"Impedanz","search_de":"Impedanzmessgeräte Messbrücken Kalibrierung — Impedanz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Impedanz Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 1 kHz f = 1 kHz f = 100 kHz f = 100 kHz LMEEiO/5","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Impedanzmessgeräte\nMessbrücken","methodology_zh":"校准 — 阻抗","parameters_zh":[{"name":"f = 1 kHz","range":"90 Ω to 900 kΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"φ","cmc":"0,01 °"},{"name":"f = 100 kHz","range":"9 Ω to 9 kΩ","cmc":"0,2 %"},{"name":"f = 100 kHz","range":"φ","cmc":"0,2 °"}],"regulatory_area_zh":"阻抗","search_zh":"阻抗表 电桥 校准 — 阻抗 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 阻抗 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 1 kHz f = 1 kHz f = 100 kHz f = 100 kHz LMEEiO/5","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"阻抗表\n电桥","methodology_cs":"Kalibrace — Impedance","parameters_cs":[{"name":"f = 1 kHz","range":"90 Ω to 900 kΩ","cmc":"0,02 %"},{"name":"f = 1 kHz","range":"φ","cmc":"0,01 °"},{"name":"f = 100 kHz","range":"9 Ω to 9 kΩ","cmc":"0,2 %"},{"name":"f = 100 kHz","range":"φ","cmc":"0,2 °"}],"regulatory_area_cs":"Impedance","search_cs":"Měřiče impedance Můstky Kalibrace — Impedance Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Impedance Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 1 kHz f = 1 kHz f = 100 kHz f = 100 kHz LMEEiO/5","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče impedance\nMůstky"},{"_id":"7004a511a95d6578f2fce285","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki parametrów sieci","test_object_en":"Power network parameter meters","methodology":"Wzorcowanie — Impedancja","methodology_en":"Calibration — Impedance","parameters":[{"name":"f = 50 Hz","range":"0,1 Ω do 1 Ω","cmc":"0,3 %"},{"name":"f = 50 Hz","range":"1 Ω do 1 kΩ","cmc":"0,05 %"}],"parameters_en":[{"name":"f = 50 Hz","range":"0,1 Ω to 1 Ω","cmc":"0,3 %"},{"name":"f = 50 Hz","range":"1 Ω to 1 kΩ","cmc":"0,05 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Impedancja\nZakres:\nf = 50 Hz 0,1 Ω do 1 Ω CMC 0,3 %\nf = 50 Hz 1 Ω do 1 kΩ CMC 0,05 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/35","norm_bases":["LMEEiO/35"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Impedancja","regulatory_area_en":"Impedance","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki parametrów sieci Wzorcowanie — Impedancja\nZakres:\nf = 50 Hz 0,1 Ω do 1 Ω CMC 0,3 %\nf = 50 Hz 1 Ω do 1 kΩ CMC 0,05 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/35 Mierniki parametrow sieci Wzorcowanie — Impedancja\nZakres:\nf = 50 Hz 0,1 Ω do 1 Ω CMC 0,3 %\nf = 50 Hz 1 Ω do 1 kΩ CMC 0,05 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/35","search_en":"Power network parameter meters Calibration — Impedance Internal procedure; Direct method; At permanent location (S) and outside of it (P) Impedance Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 Hz f = 50 Hz LMEEiO/35","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":24,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Impedanz","parameters_de":[{"name":"f = 50 Hz","range":"0,1 Ω to 1 Ω","cmc":"0,3 %"},{"name":"f = 50 Hz","range":"1 Ω to 1 kΩ","cmc":"0,05 %"}],"regulatory_area_de":"Impedanz","search_de":"Netzparametermessgeräte Kalibrierung — Impedanz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Impedanz Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 Hz f = 50 Hz LMEEiO/35","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Netzparametermessgeräte","methodology_zh":"校准 — 阻抗","parameters_zh":[{"name":"f = 50 Hz","range":"0,1 Ω to 1 Ω","cmc":"0,3 %"},{"name":"f = 50 Hz","range":"1 Ω to 1 kΩ","cmc":"0,05 %"}],"regulatory_area_zh":"阻抗","search_zh":"电网参数测量仪 校准 — 阻抗 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 阻抗 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 Hz f = 50 Hz LMEEiO/35","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电网参数测量仪","methodology_cs":"Kalibrace — Impedance","parameters_cs":[{"name":"f = 50 Hz","range":"0,1 Ω to 1 Ω","cmc":"0,3 %"},{"name":"f = 50 Hz","range":"1 Ω to 1 kΩ","cmc":"0,05 %"}],"regulatory_area_cs":"Impedance","search_cs":"Měřiče parametrů sítě Kalibrace — Impedance Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Impedance Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 Hz f = 50 Hz LMEEiO/35","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče parametrů sítě"},{"_id":"03bab70ee6d7d6a8a21a9519","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Indukcyjność własna\nCewki wzorcowe stałe\nCewki wzorcowe regulowane\nMostki\nMultimetry\nMierniki indukcyjności\nMierniki RLC","test_object_en":"Self-inductance\nFixed standard inductors\nVariable standard inductors\nBridges\nMultimeters\nInductance meters\nRLC meters","methodology":"Wzorcowanie — Indukcyjność","methodology_en":"Calibration — Inductance","parameters":[{"name":"f = 1 kHz","range":"1 µH do 10 µH","cmc":"0,06 µH"},{"name":"f = 1 kHz","range":"10 µH do 50 µH","cmc":"0,07 µH"},{"name":"f = 1 kHz","range":"50 µH do 1 mH","cmc":"0,06 %"},{"name":"f = 1 kHz","range":"1 mH do 1 H","cmc":"0,03 %"},{"name":"f = 40 Hz do 55 Hz","range":"300 µH do 1 mH","cmc":"0,6 %"},{"name":"f = 40 Hz do 55 Hz","range":"1 mH do 90 mH","cmc":"0,12 %"},{"name":"f = 40 Hz do 55 Hz","range":"90 mH do 10 H","cmc":"0,07 %"},{"name":"f = 55 Hz do 6 kHz","range":"10 µH do 100 µH","cmc":"0,07 %"},{"name":"f = 55 Hz do 6 kHz","range":"100 µH do 1 H","cmc":"0,04 %"},{"name":"f = 55 Hz do 1 kHz","range":"1 H do 10 H","cmc":"0,04%"},{"name":"f = 6 kHz do 10 kHz","range":"10 µH do 100 µH","cmc":"0,08 %"},{"name":"f = 6 kHz do 10 kHz","range":"100 µH do 1 H","cmc":"0,05 %"},{"name":"f = 10 kHz do 20 kHz","range":"10 µH do 100 µH","cmc":"0,09 %"},{"name":"f = 10 kHz do 20 kHz","range":"100 µH do 100 mH","cmc":"0,07 %"},{"name":"f = 20 kHz do 50 kHz","range":"10 µH do 10 mH","cmc":"0,1 %"},{"name":"f = 50 kHz do 100 kHz","range":"10 µH do 10 mH","cmc":"0,2 %"}],"parameters_en":[{"name":"f = 1 kHz","range":"1 µH to 10 µH","cmc":"0,06 µH"},{"name":"f = 1 kHz","range":"10 µH to 50 µH","cmc":"0,07 µH"},{"name":"f = 1 kHz","range":"50 µH to 1 mH","cmc":"0,06 %"},{"name":"f = 1 kHz","range":"1 mH to 1 H","cmc":"0,03 %"},{"name":"f = 40 Hz to 55 Hz","range":"300 µH to 1 mH","cmc":"0,6 %"},{"name":"f = 40 Hz to 55 Hz","range":"1 mH to 90 mH","cmc":"0,12 %"},{"name":"f = 40 Hz to 55 Hz","range":"90 mH to 10 H","cmc":"0,07 %"},{"name":"f = 55 Hz to 6 kHz","range":"10 µH to 100 µH","cmc":"0,07 %"},{"name":"f = 55 Hz to 6 kHz","range":"100 µH to 1 H","cmc":"0,04 %"},{"name":"f = 55 Hz to 1 kHz","range":"1 H to 10 H","cmc":"0,04%"},{"name":"f = 6 kHz to 10 kHz","range":"10 µH to 100 µH","cmc":"0,08 %"},{"name":"f = 6 kHz to 10 kHz","range":"100 µH to 1 H","cmc":"0,05 %"},{"name":"f = 10 kHz to 20 kHz","range":"10 µH to 100 µH","cmc":"0,09 %"},{"name":"f = 10 kHz to 20 kHz","range":"100 µH to 100 mH","cmc":"0,07 %"},{"name":"f = 20 kHz to 50 kHz","range":"10 µH to 10 mH","cmc":"0,1 %"},{"name":"f = 50 kHz to 100 kHz","range":"10 µH to 10 mH","cmc":"0,2 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Indukcyjność\nZakres:\nf = 1 kHz 1 µH do 10 µH CMC 0,06 µH\nf = 1 kHz 10 µH do 50 µH CMC 0,07 µH\nf = 1 kHz 50 µH do 1 mH CMC 0,06 %\nf = 1 kHz 1 mH do 1 H CMC 0,03 %\nf = 40 Hz do 55 Hz 300 µH do 1 mH CMC 0,6 %\nf = 40 Hz do 55 Hz 1 mH do 90 mH CMC 0,12 %\nf = 40 Hz do 55 Hz 90 mH do 10 H CMC 0,07 %\nf = 55 Hz do 6 kHz 10 µH do 100 µH CMC 0,07 %\nf = 55 Hz do 6 kHz 100 µH do 1 H CMC 0,04 %\nf = 55 Hz do 1 kHz 1 H do 10 H CMC 0,04%\nf = 6 kHz do 10 kHz 10 µH do 100 µH CMC 0,08 %\nf = 6 kHz do 10 kHz 100 µH do 1 H CMC 0,05 %\nf = 10 kHz do 20 kHz 10 µH do 100 µH CMC 0,09 %\nf = 10 kHz do 20 kHz 100 µH do 100 mH CMC 0,07 %\nf = 20 kHz do 50 kHz 10 µH do 10 mH CMC 0,1 %\nf = 50 kHz do 100 kHz 10 µH do 10 mH CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/14\nLMEEiO/5","norm_bases":["LMEEiO/14","LMEEiO/5"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Indukcyjność","regulatory_area_en":"Inductance","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Indukcyjność własna\nCewki wzorcowe stałe\nCewki wzorcowe regulowane\nMostki\nMultimetry\nMierniki indukcyjności\nMierniki RLC Wzorcowanie — Indukcyjność\nZakres:\nf = 1 kHz 1 µH do 10 µH CMC 0,06 µH\nf = 1 kHz 10 µH do 50 µH CMC 0,07 µH\nf = 1 kHz 50 µH do 1 mH CMC 0,06 %\nf = 1 kHz 1 mH do 1 H CMC 0,03 %\nf = 40 Hz do 55 Hz 300 µH do 1 mH CMC 0,6 %\nf = 40 Hz do 55 Hz 1 mH do 90 mH CMC 0,12 %\nf = 40 Hz do 55 Hz 90 mH do 10 H CMC 0,07 %\nf = 55 Hz do 6 kHz 10 µH do 100 µH CMC 0,07 %\nf = 55 Hz do 6 kHz 100 µH do 1 H CMC 0,04 %\nf = 55 Hz do 1 kHz 1 H do 10 H CMC 0,04%\nf = 6 kHz do 10 kHz 10 µH do 100 µH CMC 0,08 %\nf = 6 kHz do 10 kHz 100 µH do 1 H CMC 0,05 %\nf = 10 kHz do 20 kHz 10 µH do 100 µH CMC 0,09 %\nf = 10 kHz do 20 kHz 100 µH do 100 mH CMC 0,07 %\nf = 20 kHz do 50 kHz 10 µH do 10 mH CMC 0,1 %\nf = 50 kHz do 100 kHz 10 µH do 10 mH CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/14\nLMEEiO/5 Indukcyjnosc wlasna\nCewki wzorcowe stale\nCewki wzorcowe regulowane\nMostki\nMultimetry\nMierniki indukcyjnosci\nMierniki RLC Wzorcowanie — Indukcyjnosc\nZakres:\nf = 1 kHz 1 µH do 10 µH CMC 0,06 µH\nf = 1 kHz 10 µH do 50 µH CMC 0,07 µH\nf = 1 kHz 50 µH do 1 mH CMC 0,06 %\nf = 1 kHz 1 mH do 1 H CMC 0,03 %\nf = 40 Hz do 55 Hz 300 µH do 1 mH CMC 0,6 %\nf = 40 Hz do 55 Hz 1 mH do 90 mH CMC 0,12 %\nf = 40 Hz do 55 Hz 90 mH do 10 H CMC 0,07 %\nf = 55 Hz do 6 kHz 10 µH do 100 µH CMC 0,07 %\nf = 55 Hz do 6 kHz 100 µH do 1 H CMC 0,04 %\nf = 55 Hz do 1 kHz 1 H do 10 H CMC 0,04%\nf = 6 kHz do 10 kHz 10 µH do 100 µH CMC 0,08 %\nf = 6 kHz do 10 kHz 100 µH do 1 H CMC 0,05 %\nf = 10 kHz do 20 kHz 10 µH do 100 µH CMC 0,09 %\nf = 10 kHz do 20 kHz 100 µH do 100 mH CMC 0,07 %\nf = 20 kHz do 50 kHz 10 µH do 10 mH CMC 0,1 %\nf = 50 kHz do 100 kHz 10 µH do 10 mH CMC 0,2 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/14\nLMEEiO/5","search_en":"Self-inductance Fixed standard inductors Variable standard inductors Bridges Multimeters Inductance meters RLC meters Calibration — Inductance Internal procedure; Direct method; At permanent location (S) and outside of it (P) Inductance Internal procedure Direct method At permanent location (S) and outside of it (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 40 Hz to 55 Hz f = 40 Hz to 55 Hz f = 40 Hz to 55 Hz f = 55 Hz to 6 kHz f = 55 Hz to 6 kHz f = 55 Hz to 1 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 20 kHz to 50 kHz f = 50 kHz to 100 kHz LMEEiO/14 LMEEiO/5","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":25,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Induktivität","parameters_de":[{"name":"f = 1 kHz","range":"1 µH to 10 µH","cmc":"0,06 µH"},{"name":"f = 1 kHz","range":"10 µH to 50 µH","cmc":"0,07 µH"},{"name":"f = 1 kHz","range":"50 µH to 1 mH","cmc":"0,06 %"},{"name":"f = 1 kHz","range":"1 mH to 1 H","cmc":"0,03 %"},{"name":"f = 40 Hz bis 55 Hz","range":"300 µH to 1 mH","cmc":"0,6 %"},{"name":"f = 40 Hz bis 55 Hz","range":"1 mH to 90 mH","cmc":"0,12 %"},{"name":"f = 40 Hz bis 55 Hz","range":"90 mH to 10 H","cmc":"0,07 %"},{"name":"f = 55 Hz bis 6 kHz","range":"10 µH to 100 µH","cmc":"0,07 %"},{"name":"f = 55 Hz bis 6 kHz","range":"100 µH to 1 H","cmc":"0,04 %"},{"name":"f = 55 Hz bis 1 kHz","range":"1 H to 10 H","cmc":"0,04%"},{"name":"f = 6 kHz bis 10 kHz","range":"10 µH to 100 µH","cmc":"0,08 %"},{"name":"f = 6 kHz bis 10 kHz","range":"100 µH to 1 H","cmc":"0,05 %"},{"name":"f = 10 kHz bis 20 kHz","range":"10 µH to 100 µH","cmc":"0,09 %"},{"name":"f = 10 kHz bis 20 kHz","range":"100 µH to 100 mH","cmc":"0,07 %"},{"name":"f = 20 kHz bis 50 kHz","range":"10 µH to 10 mH","cmc":"0,1 %"},{"name":"f = 50 kHz bis 100 kHz","range":"10 µH to 10 mH","cmc":"0,2 %"}],"regulatory_area_de":"Induktivität","search_de":"Eigeninduktivität Feste Induktivitätsnormale Einstellbare Induktivitätsnormale Messbrücken Multimeter Induktivitätsmessgeräte RLC-Messgeräte Kalibrierung — Induktivität Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Induktivität Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 40 Hz bis 55 Hz f = 40 Hz bis 55 Hz f = 40 Hz bis 55 Hz f = 55 Hz bis 6 kHz f = 55 Hz bis 6 kHz f = 55 Hz bis 1 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 20 kHz bis 50 kHz f = 50 kHz bis 100 kHz LMEEiO/14 LMEEiO/5","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Eigeninduktivität\nFeste Induktivitätsnormale\nEinstellbare Induktivitätsnormale\nMessbrücken\nMultimeter\nInduktivitätsmessgeräte\nRLC-Messgeräte","methodology_zh":"校准 — 电感","parameters_zh":[{"name":"f = 1 kHz","range":"1 µH to 10 µH","cmc":"0,06 µH"},{"name":"f = 1 kHz","range":"10 µH to 50 µH","cmc":"0,07 µH"},{"name":"f = 1 kHz","range":"50 µH to 1 mH","cmc":"0,06 %"},{"name":"f = 1 kHz","range":"1 mH to 1 H","cmc":"0,03 %"},{"name":"f = 40 Hz 至 55 Hz","range":"300 µH to 1 mH","cmc":"0,6 %"},{"name":"f = 40 Hz 至 55 Hz","range":"1 mH to 90 mH","cmc":"0,12 %"},{"name":"f = 40 Hz 至 55 Hz","range":"90 mH to 10 H","cmc":"0,07 %"},{"name":"f = 55 Hz 至 6 kHz","range":"10 µH to 100 µH","cmc":"0,07 %"},{"name":"f = 55 Hz 至 6 kHz","range":"100 µH to 1 H","cmc":"0,04 %"},{"name":"f = 55 Hz 至 1 kHz","range":"1 H to 10 H","cmc":"0,04%"},{"name":"f = 6 kHz 至 10 kHz","range":"10 µH to 100 µH","cmc":"0,08 %"},{"name":"f = 6 kHz 至 10 kHz","range":"100 µH to 1 H","cmc":"0,05 %"},{"name":"f = 10 kHz 至 20 kHz","range":"10 µH to 100 µH","cmc":"0,09 %"},{"name":"f = 10 kHz 至 20 kHz","range":"100 µH to 100 mH","cmc":"0,07 %"},{"name":"f = 20 kHz 至 50 kHz","range":"10 µH to 10 mH","cmc":"0,1 %"},{"name":"f = 50 kHz 至 100 kHz","range":"10 µH to 10 mH","cmc":"0,2 %"}],"regulatory_area_zh":"电感","search_zh":"自感 固定标准电感 可调标准电感 电桥 万用表 电感表 RLC 测量仪 校准 — 电感 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 电感 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 40 Hz 至 55 Hz f = 40 Hz 至 55 Hz f = 40 Hz 至 55 Hz f = 55 Hz 至 6 kHz f = 55 Hz 至 6 kHz f = 55 Hz 至 1 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 20 kHz 至 50 kHz f = 50 kHz 至 100 kHz LMEEiO/14 LMEEiO/5","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"自感\n固定标准电感\n可调标准电感\n电桥\n万用表\n电感表\nRLC 测量仪","methodology_cs":"Kalibrace — Indukčnost","parameters_cs":[{"name":"f = 1 kHz","range":"1 µH to 10 µH","cmc":"0,06 µH"},{"name":"f = 1 kHz","range":"10 µH to 50 µH","cmc":"0,07 µH"},{"name":"f = 1 kHz","range":"50 µH to 1 mH","cmc":"0,06 %"},{"name":"f = 1 kHz","range":"1 mH to 1 H","cmc":"0,03 %"},{"name":"f = 40 Hz až 55 Hz","range":"300 µH to 1 mH","cmc":"0,6 %"},{"name":"f = 40 Hz až 55 Hz","range":"1 mH to 90 mH","cmc":"0,12 %"},{"name":"f = 40 Hz až 55 Hz","range":"90 mH to 10 H","cmc":"0,07 %"},{"name":"f = 55 Hz až 6 kHz","range":"10 µH to 100 µH","cmc":"0,07 %"},{"name":"f = 55 Hz až 6 kHz","range":"100 µH to 1 H","cmc":"0,04 %"},{"name":"f = 55 Hz až 1 kHz","range":"1 H to 10 H","cmc":"0,04%"},{"name":"f = 6 kHz až 10 kHz","range":"10 µH to 100 µH","cmc":"0,08 %"},{"name":"f = 6 kHz až 10 kHz","range":"100 µH to 1 H","cmc":"0,05 %"},{"name":"f = 10 kHz až 20 kHz","range":"10 µH to 100 µH","cmc":"0,09 %"},{"name":"f = 10 kHz až 20 kHz","range":"100 µH to 100 mH","cmc":"0,07 %"},{"name":"f = 20 kHz až 50 kHz","range":"10 µH to 10 mH","cmc":"0,1 %"},{"name":"f = 50 kHz až 100 kHz","range":"10 µH to 10 mH","cmc":"0,2 %"}],"regulatory_area_cs":"Indukčnost","search_cs":"Vlastní indukčnost Pevné etalonové cívky Nastavitelné etalonové cívky Můstky Multimetry Měřiče indukčnosti Měřiče RLC Kalibrace — Indukčnost Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Indukčnost Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 40 Hz až 55 Hz f = 40 Hz až 55 Hz f = 40 Hz až 55 Hz f = 55 Hz až 6 kHz f = 55 Hz až 6 kHz f = 55 Hz až 1 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 20 kHz až 50 kHz f = 50 kHz až 100 kHz LMEEiO/14 LMEEiO/5","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Vlastní indukčnost\nPevné etalonové cívky\nNastavitelné etalonové cívky\nMůstky\nMultimetry\nMěřiče indukčnosti\nMěřiče RLC"},{"_id":"c2da59b740acb436d3bed6f2","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Kondensatory wzorcowe stałe\nKondensatory wzorcowe regulowane\nKalibratory","test_object_en":"Fixed standard capacitors\nVariable standard capacitors\nCalibrators","methodology":"Wzorcowanie — Pojemność","methodology_en":"Calibration — Capacitance","parameters":[{"name":"f = 1 kHz","range":"0,001 pF","cmc":"0,00016 pF"},{"name":"f = 1 kHz","range":"0,1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"10 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"100 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1000 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1 µF do 10 µF","cmc":"0,026 %"},{"name":"f = 1 kHz","range":"10 µF do 100 µF","cmc":"0,046 %"},{"name":"f = 50 Hz do 1 kHz","range":"0,1 pF do 1 µF","cmc":"0,012 % · C + 0,00003 pF"},{"name":"f = 40 Hz do 100 Hz","range":"1 µF do 100 µF","cmc":"0,06 %"},{"name":"f = 100 Hz do 250 Hz","range":"1 µF do 100 µF","cmc":"0,053 %"},{"name":"f = 250 Hz do 1 kHz","range":"10 nF do 10 µF","cmc":"0,04 %"},{"name":"f = 250 Hz do 1 kHz","range":"10 µF do 100 µF","cmc":"0,05 %"},{"name":"f = 1 kHz do 6 kHz","range":"1 pF do 1 µF","cmc":"0,02 %"},{"name":"f = 1 kHz do 6 kHz","range":"1 µF do 10 µF","cmc":"0,06 %"},{"name":"f = 1 kHz do 6 kHz","range":"10 µF do 100 µF","cmc":"0,3 %"},{"name":"f = 6 kHz do 10 kHz","range":"1 pF µF do 1 µF","cmc":"0,022 %"},{"name":"f = 6 kHz do 10 kHz","range":"1 µF do 10 µF","cmc":"0,15 %"},{"name":"f = 6 kHz do 10 kHz","range":"10 µF do 100 µF","cmc":"1 %"},{"name":"f = 10 kHz do 20 kHz","range":"10 pF do 100 pF","cmc":"0,14 %"},{"name":"f = 10 kHz do 20 kHz","range":"0,1 nF do 100 nF","cmc":"0,08 %"},{"name":"f = 10 kHz do 20 kHz","range":"0,1 µF do 1 µF","cmc":"0,11 %"},{"name":"f = 10 kHz do 20 kHz","range":"1 µF do 10 µF","cmc":"0,36 %"},{"name":"f = 20 kHz do 50 kHz","range":"0,1 nF do 100 nF","cmc":"0,12 %"},{"name":"f = 20 kHz do 50 kHz","range":"0,1 µF do 1 µF","cmc":"0,22 %"},{"name":"f = 20 kHz do 50 kHz","range":"1 µF do 10 µF","cmc":"1,2 %"},{"name":"f = 50 kHz do 100 kHz","range":"0,1 nF do 10 nF","cmc":"0,24 %"},{"name":"f = 50 kHz do 100 kHz","range":"10 nF do 100 nF","cmc":"0,28 %"},{"name":"f = 50 kHz do 100 kHz","range":"0,1 µF do 1 µF","cmc":"0,67 %"}],"parameters_en":[{"name":"f = 1 kHz","range":"0,001 pF","cmc":"0,00016 pF"},{"name":"f = 1 kHz","range":"0,1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"10 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"100 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1000 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1 µF to 10 µF","cmc":"0,026 %"},{"name":"f = 1 kHz","range":"10 µF to 100 µF","cmc":"0,046 %"},{"name":"f = 50 Hz to 1 kHz","range":"0,1 pF to 1 µF","cmc":"0,012 % · C + 0,00003 pF"},{"name":"f = 40 Hz to 100 Hz","range":"1 µF to 100 µF","cmc":"0,06 %"},{"name":"f = 100 Hz to 250 Hz","range":"1 µF to 100 µF","cmc":"0,053 %"},{"name":"f = 250 Hz to 1 kHz","range":"10 nF to 10 µF","cmc":"0,04 %"},{"name":"f = 250 Hz to 1 kHz","range":"10 µF to 100 µF","cmc":"0,05 %"},{"name":"f = 1 kHz to 6 kHz","range":"1 pF to 1 µF","cmc":"0,02 %"},{"name":"f = 1 kHz to 6 kHz","range":"1 µF to 10 µF","cmc":"0,06 %"},{"name":"f = 1 kHz to 6 kHz","range":"10 µF to 100 µF","cmc":"0,3 %"},{"name":"f = 6 kHz to 10 kHz","range":"1 pF µF to 1 µF","cmc":"0,022 %"},{"name":"f = 6 kHz to 10 kHz","range":"1 µF to 10 µF","cmc":"0,15 %"},{"name":"f = 6 kHz to 10 kHz","range":"10 µF to 100 µF","cmc":"1 %"},{"name":"f = 10 kHz to 20 kHz","range":"10 pF to 100 pF","cmc":"0,14 %"},{"name":"f = 10 kHz to 20 kHz","range":"0,1 nF to 100 nF","cmc":"0,08 %"},{"name":"f = 10 kHz to 20 kHz","range":"0,1 µF to 1 µF","cmc":"0,11 %"},{"name":"f = 10 kHz to 20 kHz","range":"1 µF to 10 µF","cmc":"0,36 %"},{"name":"f = 20 kHz to 50 kHz","range":"0,1 nF to 100 nF","cmc":"0,12 %"},{"name":"f = 20 kHz to 50 kHz","range":"0,1 µF to 1 µF","cmc":"0,22 %"},{"name":"f = 20 kHz to 50 kHz","range":"1 µF to 10 µF","cmc":"1,2 %"},{"name":"f = 50 kHz to 100 kHz","range":"0,1 nF to 10 nF","cmc":"0,24 %"},{"name":"f = 50 kHz to 100 kHz","range":"10 nF to 100 nF","cmc":"0,28 %"},{"name":"f = 50 kHz to 100 kHz","range":"0,1 µF to 1 µF","cmc":"0,67 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Pojemność\nZakres:\nf = 1 kHz 0,001 pF CMC 0,00016 pF\nf = 1 kHz 0,1 pF CMC 0,01 %\nf = 1 kHz 1 pF CMC 0,01 %\nf = 1 kHz 10 pF CMC 0,003 %\nf = 1 kHz 100 pF CMC 0,003 %\nf = 1 kHz 1000 pF CMC 0,003 %\nf = 1 kHz 1 µF do 10 µF CMC 0,026 %\nf = 1 kHz 10 µF do 100 µF CMC 0,046 %\nf = 50 Hz do 1 kHz 0,1 pF do 1 µF CMC 0,012 % · C + 0,00003 pF\nf = 40 Hz do 100 Hz 1 µF do 100 µF CMC 0,06 %\nf = 100 Hz do 250 Hz 1 µF do 100 µF CMC 0,053 %\nf = 250 Hz do 1 kHz 10 nF do 10 µF CMC 0,04 %\nf = 250 Hz do 1 kHz 10 µF do 100 µF CMC 0,05 %\nf = 1 kHz do 6 kHz 1 pF do 1 µF CMC 0,02 %\nf = 1 kHz do 6 kHz 1 µF do 10 µF CMC 0,06 %\nf = 1 kHz do 6 kHz 10 µF do 100 µF CMC 0,3 %\nf = 6 kHz do 10 kHz 1 pF µF do 1 µF CMC 0,022 %\nf = 6 kHz do 10 kHz 1 µF do 10 µF CMC 0,15 %\nf = 6 kHz do 10 kHz 10 µF do 100 µF CMC 1 %\nf = 10 kHz do 20 kHz 10 pF do 100 pF CMC 0,14 %\nf = 10 kHz do 20 kHz 0,1 nF do 100 nF CMC 0,08 %\nf = 10 kHz do 20 kHz 0,1 µF do 1 µF CMC 0,11 %\nf = 10 kHz do 20 kHz 1 µF do 10 µF CMC 0,36 %\nf = 20 kHz do 50 kHz 0,1 nF do 100 nF CMC 0,12 %\nf = 20 kHz do 50 kHz 0,1 µF do 1 µF CMC 0,22 %\nf = 20 kHz do 50 kHz 1 µF do 10 µF CMC 1,2 %\nf = 50 kHz do 100 kHz 0,1 nF do 10 nF CMC 0,24 %\nf = 50 kHz do 100 kHz 10 nF do 100 nF CMC 0,28 %\nf = 50 kHz do 100 kHz 0,1 µF do 1 µF CMC 0,67 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/14","norm_bases":["LMEEiO/14"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Pojemność","regulatory_area_en":"Capacitance","outside_premises":true,"location_of_activity":"S, P","note":"C – wielkość mierzona (F)","note_en":"C – measured value (F)","search_text":"Kondensatory wzorcowe stałe\nKondensatory wzorcowe regulowane\nKalibratory Wzorcowanie — Pojemność\nZakres:\nf = 1 kHz 0,001 pF CMC 0,00016 pF\nf = 1 kHz 0,1 pF CMC 0,01 %\nf = 1 kHz 1 pF CMC 0,01 %\nf = 1 kHz 10 pF CMC 0,003 %\nf = 1 kHz 100 pF CMC 0,003 %\nf = 1 kHz 1000 pF CMC 0,003 %\nf = 1 kHz 1 µF do 10 µF CMC 0,026 %\nf = 1 kHz 10 µF do 100 µF CMC 0,046 %\nf = 50 Hz do 1 kHz 0,1 pF do 1 µF CMC 0,012 % · C + 0,00003 pF\nf = 40 Hz do 100 Hz 1 µF do 100 µF CMC 0,06 %\nf = 100 Hz do 250 Hz 1 µF do 100 µF CMC 0,053 %\nf = 250 Hz do 1 kHz 10 nF do 10 µF CMC 0,04 %\nf = 250 Hz do 1 kHz 10 µF do 100 µF CMC 0,05 %\nf = 1 kHz do 6 kHz 1 pF do 1 µF CMC 0,02 %\nf = 1 kHz do 6 kHz 1 µF do 10 µF CMC 0,06 %\nf = 1 kHz do 6 kHz 10 µF do 100 µF CMC 0,3 %\nf = 6 kHz do 10 kHz 1 pF µF do 1 µF CMC 0,022 %\nf = 6 kHz do 10 kHz 1 µF do 10 µF CMC 0,15 %\nf = 6 kHz do 10 kHz 10 µF do 100 µF CMC 1 %\nf = 10 kHz do 20 kHz 10 pF do 100 pF CMC 0,14 %\nf = 10 kHz do 20 kHz 0,1 nF do 100 nF CMC 0,08 %\nf = 10 kHz do 20 kHz 0,1 µF do 1 µF CMC 0,11 %\nf = 10 kHz do 20 kHz 1 µF do 10 µF CMC 0,36 %\nf = 20 kHz do 50 kHz 0,1 nF do 100 nF CMC 0,12 %\nf = 20 kHz do 50 kHz 0,1 µF do 1 µF CMC 0,22 %\nf = 20 kHz do 50 kHz 1 µF do 10 µF CMC 1,2 %\nf = 50 kHz do 100 kHz 0,1 nF do 10 nF CMC 0,24 %\nf = 50 kHz do 100 kHz 10 nF do 100 nF CMC 0,28 %\nf = 50 kHz do 100 kHz 0,1 µF do 1 µF CMC 0,67 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/14 Kondensatory wzorcowe stale\nKondensatory wzorcowe regulowane\nKalibratory Wzorcowanie — Pojemnosc\nZakres:\nf = 1 kHz 0,001 pF CMC 0,00016 pF\nf = 1 kHz 0,1 pF CMC 0,01 %\nf = 1 kHz 1 pF CMC 0,01 %\nf = 1 kHz 10 pF CMC 0,003 %\nf = 1 kHz 100 pF CMC 0,003 %\nf = 1 kHz 1000 pF CMC 0,003 %\nf = 1 kHz 1 µF do 10 µF CMC 0,026 %\nf = 1 kHz 10 µF do 100 µF CMC 0,046 %\nf = 50 Hz do 1 kHz 0,1 pF do 1 µF CMC 0,012 % · C + 0,00003 pF\nf = 40 Hz do 100 Hz 1 µF do 100 µF CMC 0,06 %\nf = 100 Hz do 250 Hz 1 µF do 100 µF CMC 0,053 %\nf = 250 Hz do 1 kHz 10 nF do 10 µF CMC 0,04 %\nf = 250 Hz do 1 kHz 10 µF do 100 µF CMC 0,05 %\nf = 1 kHz do 6 kHz 1 pF do 1 µF CMC 0,02 %\nf = 1 kHz do 6 kHz 1 µF do 10 µF CMC 0,06 %\nf = 1 kHz do 6 kHz 10 µF do 100 µF CMC 0,3 %\nf = 6 kHz do 10 kHz 1 pF µF do 1 µF CMC 0,022 %\nf = 6 kHz do 10 kHz 1 µF do 10 µF CMC 0,15 %\nf = 6 kHz do 10 kHz 10 µF do 100 µF CMC 1 %\nf = 10 kHz do 20 kHz 10 pF do 100 pF CMC 0,14 %\nf = 10 kHz do 20 kHz 0,1 nF do 100 nF CMC 0,08 %\nf = 10 kHz do 20 kHz 0,1 µF do 1 µF CMC 0,11 %\nf = 10 kHz do 20 kHz 1 µF do 10 µF CMC 0,36 %\nf = 20 kHz do 50 kHz 0,1 nF do 100 nF CMC 0,12 %\nf = 20 kHz do 50 kHz 0,1 µF do 1 µF CMC 0,22 %\nf = 20 kHz do 50 kHz 1 µF do 10 µF CMC 1,2 %\nf = 50 kHz do 100 kHz 0,1 nF do 10 nF CMC 0,24 %\nf = 50 kHz do 100 kHz 10 nF do 100 nF CMC 0,28 %\nf = 50 kHz do 100 kHz 0,1 µF do 1 µF CMC 0,67 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/14","search_en":"Fixed standard capacitors Variable standard capacitors Calibrators Calibration — Capacitance Internal procedure; Direct method; At permanent location (S) and outside of it (P) Capacitance Internal procedure Direct method At permanent location (S) and outside of it (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 50 Hz to 1 kHz f = 40 Hz to 100 Hz f = 100 Hz to 250 Hz f = 250 Hz to 1 kHz f = 250 Hz to 1 kHz f = 1 kHz to 6 kHz f = 1 kHz to 6 kHz f = 1 kHz to 6 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz LMEEiO/14","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":26,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Kapazität","parameters_de":[{"name":"f = 1 kHz","range":"0,001 pF","cmc":"0,00016 pF"},{"name":"f = 1 kHz","range":"0,1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"10 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"100 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1000 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1 µF to 10 µF","cmc":"0,026 %"},{"name":"f = 1 kHz","range":"10 µF to 100 µF","cmc":"0,046 %"},{"name":"f = 50 Hz bis 1 kHz","range":"0,1 pF to 1 µF","cmc":"0,012 % · C + 0,00003 pF"},{"name":"f = 40 Hz bis 100 Hz","range":"1 µF to 100 µF","cmc":"0,06 %"},{"name":"f = 100 Hz bis 250 Hz","range":"1 µF to 100 µF","cmc":"0,053 %"},{"name":"f = 250 Hz bis 1 kHz","range":"10 nF to 10 µF","cmc":"0,04 %"},{"name":"f = 250 Hz bis 1 kHz","range":"10 µF to 100 µF","cmc":"0,05 %"},{"name":"f = 1 kHz bis 6 kHz","range":"1 pF to 1 µF","cmc":"0,02 %"},{"name":"f = 1 kHz bis 6 kHz","range":"1 µF to 10 µF","cmc":"0,06 %"},{"name":"f = 1 kHz bis 6 kHz","range":"10 µF to 100 µF","cmc":"0,3 %"},{"name":"f = 6 kHz bis 10 kHz","range":"1 pF µF to 1 µF","cmc":"0,022 %"},{"name":"f = 6 kHz bis 10 kHz","range":"1 µF to 10 µF","cmc":"0,15 %"},{"name":"f = 6 kHz bis 10 kHz","range":"10 µF to 100 µF","cmc":"1 %"},{"name":"f = 10 kHz bis 20 kHz","range":"10 pF to 100 pF","cmc":"0,14 %"},{"name":"f = 10 kHz bis 20 kHz","range":"0,1 nF to 100 nF","cmc":"0,08 %"},{"name":"f = 10 kHz bis 20 kHz","range":"0,1 µF to 1 µF","cmc":"0,11 %"},{"name":"f = 10 kHz bis 20 kHz","range":"1 µF to 10 µF","cmc":"0,36 %"},{"name":"f = 20 kHz bis 50 kHz","range":"0,1 nF to 100 nF","cmc":"0,12 %"},{"name":"f = 20 kHz bis 50 kHz","range":"0,1 µF to 1 µF","cmc":"0,22 %"},{"name":"f = 20 kHz bis 50 kHz","range":"1 µF to 10 µF","cmc":"1,2 %"},{"name":"f = 50 kHz bis 100 kHz","range":"0,1 nF to 10 nF","cmc":"0,24 %"},{"name":"f = 50 kHz bis 100 kHz","range":"10 nF to 100 nF","cmc":"0,28 %"},{"name":"f = 50 kHz bis 100 kHz","range":"0,1 µF to 1 µF","cmc":"0,67 %"}],"regulatory_area_de":"Kapazität","search_de":"Feste Kapazitätsnormale Einstellbare Kapazitätsnormale Kalibratoren Kalibrierung — Kapazität Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Kapazität Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 50 Hz bis 1 kHz f = 40 Hz bis 100 Hz f = 100 Hz bis 250 Hz f = 250 Hz bis 1 kHz f = 250 Hz bis 1 kHz f = 1 kHz bis 6 kHz f = 1 kHz bis 6 kHz f = 1 kHz bis 6 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz LMEEiO/14","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Feste Kapazitätsnormale\nEinstellbare Kapazitätsnormale\nKalibratoren","methodology_zh":"校准 — 电容","parameters_zh":[{"name":"f = 1 kHz","range":"0,001 pF","cmc":"0,00016 pF"},{"name":"f = 1 kHz","range":"0,1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"10 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"100 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1000 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1 µF to 10 µF","cmc":"0,026 %"},{"name":"f = 1 kHz","range":"10 µF to 100 µF","cmc":"0,046 %"},{"name":"f = 50 Hz 至 1 kHz","range":"0,1 pF to 1 µF","cmc":"0,012 % · C + 0,00003 pF"},{"name":"f = 40 Hz 至 100 Hz","range":"1 µF to 100 µF","cmc":"0,06 %"},{"name":"f = 100 Hz 至 250 Hz","range":"1 µF to 100 µF","cmc":"0,053 %"},{"name":"f = 250 Hz 至 1 kHz","range":"10 nF to 10 µF","cmc":"0,04 %"},{"name":"f = 250 Hz 至 1 kHz","range":"10 µF to 100 µF","cmc":"0,05 %"},{"name":"f = 1 kHz 至 6 kHz","range":"1 pF to 1 µF","cmc":"0,02 %"},{"name":"f = 1 kHz 至 6 kHz","range":"1 µF to 10 µF","cmc":"0,06 %"},{"name":"f = 1 kHz 至 6 kHz","range":"10 µF to 100 µF","cmc":"0,3 %"},{"name":"f = 6 kHz 至 10 kHz","range":"1 pF µF to 1 µF","cmc":"0,022 %"},{"name":"f = 6 kHz 至 10 kHz","range":"1 µF to 10 µF","cmc":"0,15 %"},{"name":"f = 6 kHz 至 10 kHz","range":"10 µF to 100 µF","cmc":"1 %"},{"name":"f = 10 kHz 至 20 kHz","range":"10 pF to 100 pF","cmc":"0,14 %"},{"name":"f = 10 kHz 至 20 kHz","range":"0,1 nF to 100 nF","cmc":"0,08 %"},{"name":"f = 10 kHz 至 20 kHz","range":"0,1 µF to 1 µF","cmc":"0,11 %"},{"name":"f = 10 kHz 至 20 kHz","range":"1 µF to 10 µF","cmc":"0,36 %"},{"name":"f = 20 kHz 至 50 kHz","range":"0,1 nF to 100 nF","cmc":"0,12 %"},{"name":"f = 20 kHz 至 50 kHz","range":"0,1 µF to 1 µF","cmc":"0,22 %"},{"name":"f = 20 kHz 至 50 kHz","range":"1 µF to 10 µF","cmc":"1,2 %"},{"name":"f = 50 kHz 至 100 kHz","range":"0,1 nF to 10 nF","cmc":"0,24 %"},{"name":"f = 50 kHz 至 100 kHz","range":"10 nF to 100 nF","cmc":"0,28 %"},{"name":"f = 50 kHz 至 100 kHz","range":"0,1 µF to 1 µF","cmc":"0,67 %"}],"regulatory_area_zh":"容量","search_zh":"固定标准电容器 可调标准电容器 校准器 校准 — 电容 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 容量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 50 Hz 至 1 kHz f = 40 Hz 至 100 Hz f = 100 Hz 至 250 Hz f = 250 Hz 至 1 kHz f = 250 Hz 至 1 kHz f = 1 kHz 至 6 kHz f = 1 kHz 至 6 kHz f = 1 kHz 至 6 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz LMEEiO/14","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"固定标准电容器\n可调标准电容器\n校准器","methodology_cs":"Kalibrace — Kapacita","parameters_cs":[{"name":"f = 1 kHz","range":"0,001 pF","cmc":"0,00016 pF"},{"name":"f = 1 kHz","range":"0,1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"10 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"100 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1000 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1 µF to 10 µF","cmc":"0,026 %"},{"name":"f = 1 kHz","range":"10 µF to 100 µF","cmc":"0,046 %"},{"name":"f = 50 Hz až 1 kHz","range":"0,1 pF to 1 µF","cmc":"0,012 % · C + 0,00003 pF"},{"name":"f = 40 Hz až 100 Hz","range":"1 µF to 100 µF","cmc":"0,06 %"},{"name":"f = 100 Hz až 250 Hz","range":"1 µF to 100 µF","cmc":"0,053 %"},{"name":"f = 250 Hz až 1 kHz","range":"10 nF to 10 µF","cmc":"0,04 %"},{"name":"f = 250 Hz až 1 kHz","range":"10 µF to 100 µF","cmc":"0,05 %"},{"name":"f = 1 kHz až 6 kHz","range":"1 pF to 1 µF","cmc":"0,02 %"},{"name":"f = 1 kHz až 6 kHz","range":"1 µF to 10 µF","cmc":"0,06 %"},{"name":"f = 1 kHz až 6 kHz","range":"10 µF to 100 µF","cmc":"0,3 %"},{"name":"f = 6 kHz až 10 kHz","range":"1 pF µF to 1 µF","cmc":"0,022 %"},{"name":"f = 6 kHz až 10 kHz","range":"1 µF to 10 µF","cmc":"0,15 %"},{"name":"f = 6 kHz až 10 kHz","range":"10 µF to 100 µF","cmc":"1 %"},{"name":"f = 10 kHz až 20 kHz","range":"10 pF to 100 pF","cmc":"0,14 %"},{"name":"f = 10 kHz až 20 kHz","range":"0,1 nF to 100 nF","cmc":"0,08 %"},{"name":"f = 10 kHz až 20 kHz","range":"0,1 µF to 1 µF","cmc":"0,11 %"},{"name":"f = 10 kHz až 20 kHz","range":"1 µF to 10 µF","cmc":"0,36 %"},{"name":"f = 20 kHz až 50 kHz","range":"0,1 nF to 100 nF","cmc":"0,12 %"},{"name":"f = 20 kHz až 50 kHz","range":"0,1 µF to 1 µF","cmc":"0,22 %"},{"name":"f = 20 kHz až 50 kHz","range":"1 µF to 10 µF","cmc":"1,2 %"},{"name":"f = 50 kHz až 100 kHz","range":"0,1 nF to 10 nF","cmc":"0,24 %"},{"name":"f = 50 kHz až 100 kHz","range":"10 nF to 100 nF","cmc":"0,28 %"},{"name":"f = 50 kHz až 100 kHz","range":"0,1 µF to 1 µF","cmc":"0,67 %"}],"regulatory_area_cs":"Objem","search_cs":"Pevné etalonové kondenzátory Nastavitelné etalonové kondenzátory Kalibrátory Kalibrace — Kapacita Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Objem Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 50 Hz až 1 kHz f = 40 Hz až 100 Hz f = 100 Hz až 250 Hz f = 250 Hz až 1 kHz f = 250 Hz až 1 kHz f = 1 kHz až 6 kHz f = 1 kHz až 6 kHz f = 1 kHz až 6 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz LMEEiO/14","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Pevné etalonové kondenzátory\nNastavitelné etalonové kondenzátory\nKalibrátory"},{"_id":"c07a6f79fe1cee6f46a7b7bb","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mostki\nMierniki RLC\nMultimetry\nMierniki pojemności","test_object_en":"Bridges\nRLC meters\nMultimeters\nCapacitance meters","methodology":"Wzorcowanie — Pojemność","methodology_en":"Calibration — Capacitance","parameters":[{"name":"f = 1 kHz","range":"0,1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"10 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"100 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1000 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1 µF do 10 µF","cmc":"0,026 %"},{"name":"f = 1 kHz","range":"10 µF do 100 µF","cmc":"0,046 %"},{"name":"f = 50 Hz do 1 kHz","range":"0,1 pF do 1 µF","cmc":"0,012 % · C + 0,00003 pF"},{"name":"f = 40 Hz do 100 Hz","range":"1 µF do 100 µF","cmc":"0,06 %"},{"name":"f = 100 Hz do 250 Hz","range":"1 µF do 100 µF","cmc":"0,053 %"},{"name":"f = 250 Hz do 1 kHz","range":"10 nF do 10 µF","cmc":"0,04 %"},{"name":"f = 250 Hz do 1 kHz","range":"10 µF do 100 µF","cmc":"0,05 %"},{"name":"f = 1 kHz do 6 kHz","range":"1 pF do 1 µF","cmc":"0,02 %"},{"name":"f = 1 kHz do 6 kHz","range":"1 µF do 10 µF","cmc":"0,06 %"},{"name":"f = 1 kHz do 6 kHz","range":"10 µF do 100 µF","cmc":"0,3 %"},{"name":"f = 6 kHz do 10 kHz","range":"1 pF do 1 µF","cmc":"0,022 %"},{"name":"f = 6 kHz do 10 kHz","range":"1 µF do 10 µF","cmc":"0,15 %"},{"name":"f = 6 kHz do 10 kHz","range":"10 µF do 100 µF","cmc":"1 %"},{"name":"f = 10 kHz do 20 kHz","range":"10 pF do 100 pF","cmc":"0,14 %"},{"name":"f = 10 kHz do 20 kHz","range":"0,1 nF do 100 nF","cmc":"0,08 %"},{"name":"f = 10 kHz do 20 kHz","range":"0,1 µF do 1 µF","cmc":"0,11 %"},{"name":"f = 10 kHz do 20 kHz","range":"1 µF do 10 µF","cmc":"0,36 %"},{"name":"f = 20 kHz do 50 kHz","range":"0,1 nF do 100 nF","cmc":"0,12 %"},{"name":"f = 20 kHz do 50 kHz","range":"0,1 µF do 1 µF","cmc":"0,22 %"},{"name":"f = 20 kHz do 50 kHz","range":"1 µF do 10 µF","cmc":"1,2 %"},{"name":"f = 50 kHz do 100 kHz","range":"0,1 nF do 10 nF","cmc":"0,24 %"},{"name":"f = 50 kHz do 100 kHz","range":"10 nF do 100 nF","cmc":"0,28 %"},{"name":"f = 50 kHz do 100 kHz","range":"0,1 µF do 1 µF","cmc":"0,67 %"}],"parameters_en":[{"name":"f = 1 kHz","range":"0,1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"10 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"100 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1000 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1 µF to 10 µF","cmc":"0,026 %"},{"name":"f = 1 kHz","range":"10 µF to 100 µF","cmc":"0,046 %"},{"name":"f = 50 Hz to 1 kHz","range":"0,1 pF to 1 µF","cmc":"0,012 % · C + 0,00003 pF"},{"name":"f = 40 Hz to 100 Hz","range":"1 µF to 100 µF","cmc":"0,06 %"},{"name":"f = 100 Hz to 250 Hz","range":"1 µF to 100 µF","cmc":"0,053 %"},{"name":"f = 250 Hz to 1 kHz","range":"10 nF to 10 µF","cmc":"0,04 %"},{"name":"f = 250 Hz to 1 kHz","range":"10 µF to 100 µF","cmc":"0,05 %"},{"name":"f = 1 kHz to 6 kHz","range":"1 pF to 1 µF","cmc":"0,02 %"},{"name":"f = 1 kHz to 6 kHz","range":"1 µF to 10 µF","cmc":"0,06 %"},{"name":"f = 1 kHz to 6 kHz","range":"10 µF to 100 µF","cmc":"0,3 %"},{"name":"f = 6 kHz to 10 kHz","range":"1 pF to 1 µF","cmc":"0,022 %"},{"name":"f = 6 kHz to 10 kHz","range":"1 µF to 10 µF","cmc":"0,15 %"},{"name":"f = 6 kHz to 10 kHz","range":"10 µF to 100 µF","cmc":"1 %"},{"name":"f = 10 kHz to 20 kHz","range":"10 pF to 100 pF","cmc":"0,14 %"},{"name":"f = 10 kHz to 20 kHz","range":"0,1 nF to 100 nF","cmc":"0,08 %"},{"name":"f = 10 kHz to 20 kHz","range":"0,1 µF to 1 µF","cmc":"0,11 %"},{"name":"f = 10 kHz to 20 kHz","range":"1 µF to 10 µF","cmc":"0,36 %"},{"name":"f = 20 kHz to 50 kHz","range":"0,1 nF to 100 nF","cmc":"0,12 %"},{"name":"f = 20 kHz to 50 kHz","range":"0,1 µF to 1 µF","cmc":"0,22 %"},{"name":"f = 20 kHz to 50 kHz","range":"1 µF to 10 µF","cmc":"1,2 %"},{"name":"f = 50 kHz to 100 kHz","range":"0,1 nF to 10 nF","cmc":"0,24 %"},{"name":"f = 50 kHz to 100 kHz","range":"10 nF to 100 nF","cmc":"0,28 %"},{"name":"f = 50 kHz to 100 kHz","range":"0,1 µF to 1 µF","cmc":"0,67 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Pojemność\nZakres:\nf = 1 kHz 0,1 pF CMC 0,01 %\nf = 1 kHz 1 pF CMC 0,01 %\nf = 1 kHz 10 pF CMC 0,003 %\nf = 1 kHz 100 pF CMC 0,003 %\nf = 1 kHz 1000 pF CMC 0,003 %\nf = 1 kHz 1 µF do 10 µF CMC 0,026 %\nf = 1 kHz 10 µF do 100 µF CMC 0,046 %\nf = 50 Hz do 1 kHz 0,1 pF do 1 µF CMC 0,012 % · C + 0,00003 pF\nf = 40 Hz do 100 Hz 1 µF do 100 µF CMC 0,06 %\nf = 100 Hz do 250 Hz 1 µF do 100 µF CMC 0,053 %\nf = 250 Hz do 1 kHz 10 nF do 10 µF CMC 0,04 %\nf = 250 Hz do 1 kHz 10 µF do 100 µF CMC 0,05 %\nf = 1 kHz do 6 kHz 1 pF do 1 µF CMC 0,02 %\nf = 1 kHz do 6 kHz 1 µF do 10 µF CMC 0,06 %\nf = 1 kHz do 6 kHz 10 µF do 100 µF CMC 0,3 %\nf = 6 kHz do 10 kHz 1 pF do 1 µF CMC 0,022 %\nf = 6 kHz do 10 kHz 1 µF do 10 µF CMC 0,15 %\nf = 6 kHz do 10 kHz 10 µF do 100 µF CMC 1 %\nf = 10 kHz do 20 kHz 10 pF do 100 pF CMC 0,14 %\nf = 10 kHz do 20 kHz 0,1 nF do 100 nF CMC 0,08 %\nf = 10 kHz do 20 kHz 0,1 µF do 1 µF CMC 0,11 %\nf = 10 kHz do 20 kHz 1 µF do 10 µF CMC 0,36 %\nf = 20 kHz do 50 kHz 0,1 nF do 100 nF CMC 0,12 %\nf = 20 kHz do 50 kHz 0,1 µF do 1 µF CMC 0,22 %\nf = 20 kHz do 50 kHz 1 µF do 10 µF CMC 1,2 %\nf = 50 kHz do 100 kHz 0,1 nF do 10 nF CMC 0,24 %\nf = 50 kHz do 100 kHz 10 nF do 100 nF CMC 0,28 %\nf = 50 kHz do 100 kHz 0,1 µF do 1 µF CMC 0,67 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/5\nLMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["LMEEiO/5","LMEEiO/2","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Pojemność","regulatory_area_en":"Capacitance","outside_premises":true,"location_of_activity":"S, P","note":"C – wielkość mierzona (F)","note_en":"C – measured value (F)","search_text":"Mostki\nMierniki RLC\nMultimetry\nMierniki pojemności Wzorcowanie — Pojemność\nZakres:\nf = 1 kHz 0,1 pF CMC 0,01 %\nf = 1 kHz 1 pF CMC 0,01 %\nf = 1 kHz 10 pF CMC 0,003 %\nf = 1 kHz 100 pF CMC 0,003 %\nf = 1 kHz 1000 pF CMC 0,003 %\nf = 1 kHz 1 µF do 10 µF CMC 0,026 %\nf = 1 kHz 10 µF do 100 µF CMC 0,046 %\nf = 50 Hz do 1 kHz 0,1 pF do 1 µF CMC 0,012 % · C + 0,00003 pF\nf = 40 Hz do 100 Hz 1 µF do 100 µF CMC 0,06 %\nf = 100 Hz do 250 Hz 1 µF do 100 µF CMC 0,053 %\nf = 250 Hz do 1 kHz 10 nF do 10 µF CMC 0,04 %\nf = 250 Hz do 1 kHz 10 µF do 100 µF CMC 0,05 %\nf = 1 kHz do 6 kHz 1 pF do 1 µF CMC 0,02 %\nf = 1 kHz do 6 kHz 1 µF do 10 µF CMC 0,06 %\nf = 1 kHz do 6 kHz 10 µF do 100 µF CMC 0,3 %\nf = 6 kHz do 10 kHz 1 pF do 1 µF CMC 0,022 %\nf = 6 kHz do 10 kHz 1 µF do 10 µF CMC 0,15 %\nf = 6 kHz do 10 kHz 10 µF do 100 µF CMC 1 %\nf = 10 kHz do 20 kHz 10 pF do 100 pF CMC 0,14 %\nf = 10 kHz do 20 kHz 0,1 nF do 100 nF CMC 0,08 %\nf = 10 kHz do 20 kHz 0,1 µF do 1 µF CMC 0,11 %\nf = 10 kHz do 20 kHz 1 µF do 10 µF CMC 0,36 %\nf = 20 kHz do 50 kHz 0,1 nF do 100 nF CMC 0,12 %\nf = 20 kHz do 50 kHz 0,1 µF do 1 µF CMC 0,22 %\nf = 20 kHz do 50 kHz 1 µF do 10 µF CMC 1,2 %\nf = 50 kHz do 100 kHz 0,1 nF do 10 nF CMC 0,24 %\nf = 50 kHz do 100 kHz 10 nF do 100 nF CMC 0,28 %\nf = 50 kHz do 100 kHz 0,1 µF do 1 µF CMC 0,67 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/5\nLMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0 Mostki\nMierniki RLC\nMultimetry\nMierniki pojemnosci Wzorcowanie — Pojemnosc\nZakres:\nf = 1 kHz 0,1 pF CMC 0,01 %\nf = 1 kHz 1 pF CMC 0,01 %\nf = 1 kHz 10 pF CMC 0,003 %\nf = 1 kHz 100 pF CMC 0,003 %\nf = 1 kHz 1000 pF CMC 0,003 %\nf = 1 kHz 1 µF do 10 µF CMC 0,026 %\nf = 1 kHz 10 µF do 100 µF CMC 0,046 %\nf = 50 Hz do 1 kHz 0,1 pF do 1 µF CMC 0,012 % · C + 0,00003 pF\nf = 40 Hz do 100 Hz 1 µF do 100 µF CMC 0,06 %\nf = 100 Hz do 250 Hz 1 µF do 100 µF CMC 0,053 %\nf = 250 Hz do 1 kHz 10 nF do 10 µF CMC 0,04 %\nf = 250 Hz do 1 kHz 10 µF do 100 µF CMC 0,05 %\nf = 1 kHz do 6 kHz 1 pF do 1 µF CMC 0,02 %\nf = 1 kHz do 6 kHz 1 µF do 10 µF CMC 0,06 %\nf = 1 kHz do 6 kHz 10 µF do 100 µF CMC 0,3 %\nf = 6 kHz do 10 kHz 1 pF do 1 µF CMC 0,022 %\nf = 6 kHz do 10 kHz 1 µF do 10 µF CMC 0,15 %\nf = 6 kHz do 10 kHz 10 µF do 100 µF CMC 1 %\nf = 10 kHz do 20 kHz 10 pF do 100 pF CMC 0,14 %\nf = 10 kHz do 20 kHz 0,1 nF do 100 nF CMC 0,08 %\nf = 10 kHz do 20 kHz 0,1 µF do 1 µF CMC 0,11 %\nf = 10 kHz do 20 kHz 1 µF do 10 µF CMC 0,36 %\nf = 20 kHz do 50 kHz 0,1 nF do 100 nF CMC 0,12 %\nf = 20 kHz do 50 kHz 0,1 µF do 1 µF CMC 0,22 %\nf = 20 kHz do 50 kHz 1 µF do 10 µF CMC 1,2 %\nf = 50 kHz do 100 kHz 0,1 nF do 10 nF CMC 0,24 %\nf = 50 kHz do 100 kHz 10 nF do 100 nF CMC 0,28 %\nf = 50 kHz do 100 kHz 0,1 µF do 1 µF CMC 0,67 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/5\nLMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Bridges RLC meters Multimeters Capacitance meters Calibration — Capacitance Internal procedure; Direct method; At permanent location (S) and outside of it (P) Capacitance Internal procedure Direct method At permanent location (S) and outside of it (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 50 Hz to 1 kHz f = 40 Hz to 100 Hz f = 100 Hz to 250 Hz f = 250 Hz to 1 kHz f = 250 Hz to 1 kHz f = 1 kHz to 6 kHz f = 1 kHz to 6 kHz f = 1 kHz to 6 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 6 kHz to 10 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 10 kHz to 20 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz LMEEiO/5 LMEEiO/2 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":27,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/5\nLMEEiO/2 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — Kapazität","parameters_de":[{"name":"f = 1 kHz","range":"0,1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"10 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"100 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1000 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1 µF to 10 µF","cmc":"0,026 %"},{"name":"f = 1 kHz","range":"10 µF to 100 µF","cmc":"0,046 %"},{"name":"f = 50 Hz bis 1 kHz","range":"0,1 pF to 1 µF","cmc":"0,012 % · C + 0,00003 pF"},{"name":"f = 40 Hz bis 100 Hz","range":"1 µF to 100 µF","cmc":"0,06 %"},{"name":"f = 100 Hz bis 250 Hz","range":"1 µF to 100 µF","cmc":"0,053 %"},{"name":"f = 250 Hz bis 1 kHz","range":"10 nF to 10 µF","cmc":"0,04 %"},{"name":"f = 250 Hz bis 1 kHz","range":"10 µF to 100 µF","cmc":"0,05 %"},{"name":"f = 1 kHz bis 6 kHz","range":"1 pF to 1 µF","cmc":"0,02 %"},{"name":"f = 1 kHz bis 6 kHz","range":"1 µF to 10 µF","cmc":"0,06 %"},{"name":"f = 1 kHz bis 6 kHz","range":"10 µF to 100 µF","cmc":"0,3 %"},{"name":"f = 6 kHz bis 10 kHz","range":"1 pF to 1 µF","cmc":"0,022 %"},{"name":"f = 6 kHz bis 10 kHz","range":"1 µF to 10 µF","cmc":"0,15 %"},{"name":"f = 6 kHz bis 10 kHz","range":"10 µF to 100 µF","cmc":"1 %"},{"name":"f = 10 kHz bis 20 kHz","range":"10 pF to 100 pF","cmc":"0,14 %"},{"name":"f = 10 kHz bis 20 kHz","range":"0,1 nF to 100 nF","cmc":"0,08 %"},{"name":"f = 10 kHz bis 20 kHz","range":"0,1 µF to 1 µF","cmc":"0,11 %"},{"name":"f = 10 kHz bis 20 kHz","range":"1 µF to 10 µF","cmc":"0,36 %"},{"name":"f = 20 kHz bis 50 kHz","range":"0,1 nF to 100 nF","cmc":"0,12 %"},{"name":"f = 20 kHz bis 50 kHz","range":"0,1 µF to 1 µF","cmc":"0,22 %"},{"name":"f = 20 kHz bis 50 kHz","range":"1 µF to 10 µF","cmc":"1,2 %"},{"name":"f = 50 kHz bis 100 kHz","range":"0,1 nF to 10 nF","cmc":"0,24 %"},{"name":"f = 50 kHz bis 100 kHz","range":"10 nF to 100 nF","cmc":"0,28 %"},{"name":"f = 50 kHz bis 100 kHz","range":"0,1 µF to 1 µF","cmc":"0,67 %"}],"reference_de":"LMEEiO/5\nLMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"Kapazität","search_de":"Messbrücken RLC-Messgeräte Multimeter Kapazitätsmessgeräte Kalibrierung — Kapazität Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Kapazität Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 50 Hz bis 1 kHz f = 40 Hz bis 100 Hz f = 100 Hz bis 250 Hz f = 250 Hz bis 1 kHz f = 250 Hz bis 1 kHz f = 1 kHz bis 6 kHz f = 1 kHz bis 6 kHz f = 1 kHz bis 6 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 6 kHz bis 10 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 10 kHz bis 20 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz LMEEiO/5 LMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Messbrücken\nRLC-Messgeräte\nMultimeter\nKapazitätsmessgeräte","methodology_zh":"校准 — 电容","parameters_zh":[{"name":"f = 1 kHz","range":"0,1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"10 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"100 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1000 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1 µF to 10 µF","cmc":"0,026 %"},{"name":"f = 1 kHz","range":"10 µF to 100 µF","cmc":"0,046 %"},{"name":"f = 50 Hz 至 1 kHz","range":"0,1 pF to 1 µF","cmc":"0,012 % · C + 0,00003 pF"},{"name":"f = 40 Hz 至 100 Hz","range":"1 µF to 100 µF","cmc":"0,06 %"},{"name":"f = 100 Hz 至 250 Hz","range":"1 µF to 100 µF","cmc":"0,053 %"},{"name":"f = 250 Hz 至 1 kHz","range":"10 nF to 10 µF","cmc":"0,04 %"},{"name":"f = 250 Hz 至 1 kHz","range":"10 µF to 100 µF","cmc":"0,05 %"},{"name":"f = 1 kHz 至 6 kHz","range":"1 pF to 1 µF","cmc":"0,02 %"},{"name":"f = 1 kHz 至 6 kHz","range":"1 µF to 10 µF","cmc":"0,06 %"},{"name":"f = 1 kHz 至 6 kHz","range":"10 µF to 100 µF","cmc":"0,3 %"},{"name":"f = 6 kHz 至 10 kHz","range":"1 pF to 1 µF","cmc":"0,022 %"},{"name":"f = 6 kHz 至 10 kHz","range":"1 µF to 10 µF","cmc":"0,15 %"},{"name":"f = 6 kHz 至 10 kHz","range":"10 µF to 100 µF","cmc":"1 %"},{"name":"f = 10 kHz 至 20 kHz","range":"10 pF to 100 pF","cmc":"0,14 %"},{"name":"f = 10 kHz 至 20 kHz","range":"0,1 nF to 100 nF","cmc":"0,08 %"},{"name":"f = 10 kHz 至 20 kHz","range":"0,1 µF to 1 µF","cmc":"0,11 %"},{"name":"f = 10 kHz 至 20 kHz","range":"1 µF to 10 µF","cmc":"0,36 %"},{"name":"f = 20 kHz 至 50 kHz","range":"0,1 nF to 100 nF","cmc":"0,12 %"},{"name":"f = 20 kHz 至 50 kHz","range":"0,1 µF to 1 µF","cmc":"0,22 %"},{"name":"f = 20 kHz 至 50 kHz","range":"1 µF to 10 µF","cmc":"1,2 %"},{"name":"f = 50 kHz 至 100 kHz","range":"0,1 nF to 10 nF","cmc":"0,24 %"},{"name":"f = 50 kHz 至 100 kHz","range":"10 nF to 100 nF","cmc":"0,28 %"},{"name":"f = 50 kHz 至 100 kHz","range":"0,1 µF to 1 µF","cmc":"0,67 %"}],"reference_zh":"LMEEiO/5\nLMEEiO/2 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"容量","search_zh":"电桥 RLC 测量仪 万用表 电容表 校准 — 电容 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 容量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 50 Hz 至 1 kHz f = 40 Hz 至 100 Hz f = 100 Hz 至 250 Hz f = 250 Hz 至 1 kHz f = 250 Hz 至 1 kHz f = 1 kHz 至 6 kHz f = 1 kHz 至 6 kHz f = 1 kHz 至 6 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 6 kHz 至 10 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 10 kHz 至 20 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz LMEEiO/5 LMEEiO/2 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电桥\nRLC 测量仪\n万用表\n电容表","methodology_cs":"Kalibrace — Kapacita","parameters_cs":[{"name":"f = 1 kHz","range":"0,1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"1 pF","cmc":"0,01 %"},{"name":"f = 1 kHz","range":"10 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"100 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1000 pF","cmc":"0,003 %"},{"name":"f = 1 kHz","range":"1 µF to 10 µF","cmc":"0,026 %"},{"name":"f = 1 kHz","range":"10 µF to 100 µF","cmc":"0,046 %"},{"name":"f = 50 Hz až 1 kHz","range":"0,1 pF to 1 µF","cmc":"0,012 % · C + 0,00003 pF"},{"name":"f = 40 Hz až 100 Hz","range":"1 µF to 100 µF","cmc":"0,06 %"},{"name":"f = 100 Hz až 250 Hz","range":"1 µF to 100 µF","cmc":"0,053 %"},{"name":"f = 250 Hz až 1 kHz","range":"10 nF to 10 µF","cmc":"0,04 %"},{"name":"f = 250 Hz až 1 kHz","range":"10 µF to 100 µF","cmc":"0,05 %"},{"name":"f = 1 kHz až 6 kHz","range":"1 pF to 1 µF","cmc":"0,02 %"},{"name":"f = 1 kHz až 6 kHz","range":"1 µF to 10 µF","cmc":"0,06 %"},{"name":"f = 1 kHz až 6 kHz","range":"10 µF to 100 µF","cmc":"0,3 %"},{"name":"f = 6 kHz až 10 kHz","range":"1 pF to 1 µF","cmc":"0,022 %"},{"name":"f = 6 kHz až 10 kHz","range":"1 µF to 10 µF","cmc":"0,15 %"},{"name":"f = 6 kHz až 10 kHz","range":"10 µF to 100 µF","cmc":"1 %"},{"name":"f = 10 kHz až 20 kHz","range":"10 pF to 100 pF","cmc":"0,14 %"},{"name":"f = 10 kHz až 20 kHz","range":"0,1 nF to 100 nF","cmc":"0,08 %"},{"name":"f = 10 kHz až 20 kHz","range":"0,1 µF to 1 µF","cmc":"0,11 %"},{"name":"f = 10 kHz až 20 kHz","range":"1 µF to 10 µF","cmc":"0,36 %"},{"name":"f = 20 kHz až 50 kHz","range":"0,1 nF to 100 nF","cmc":"0,12 %"},{"name":"f = 20 kHz až 50 kHz","range":"0,1 µF to 1 µF","cmc":"0,22 %"},{"name":"f = 20 kHz až 50 kHz","range":"1 µF to 10 µF","cmc":"1,2 %"},{"name":"f = 50 kHz až 100 kHz","range":"0,1 nF to 10 nF","cmc":"0,24 %"},{"name":"f = 50 kHz až 100 kHz","range":"10 nF to 100 nF","cmc":"0,28 %"},{"name":"f = 50 kHz až 100 kHz","range":"0,1 µF to 1 µF","cmc":"0,67 %"}],"reference_cs":"LMEEiO/5\nLMEEiO/2 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Objem","search_cs":"Můstky Měřiče RLC Multimetry Měřiče kapacity Kalibrace — Kapacita Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Objem Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 1 kHz f = 50 Hz až 1 kHz f = 40 Hz až 100 Hz f = 100 Hz až 250 Hz f = 250 Hz až 1 kHz f = 250 Hz až 1 kHz f = 1 kHz až 6 kHz f = 1 kHz až 6 kHz f = 1 kHz až 6 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 6 kHz až 10 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 10 kHz až 20 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz LMEEiO/5 LMEEiO/2 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Můstky\nMěřiče RLC\nMultimetry\nMěřiče kapacity"},{"_id":"d83f8eddf1afc83682b22bce","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Multimetry","test_object_en":"Multimeters","methodology":"Wzorcowanie — Pojemność","methodology_en":"Calibration — Capacitance","parameters":[{"name":"","range":"11 µF do 11 mF","cmc":"0,55 %"},{"name":"","range":"11 mF do 33 mF","cmc":"0,85 %"},{"name":"","range":"33 mF do 110 mF","cmc":"1,2 %"}],"parameters_en":[{"name":"","range":"11 µF to 11 mF","cmc":"0,55 %"},{"name":"","range":"11 mF to 33 mF","cmc":"0,85 %"},{"name":"","range":"33 mF to 110 mF","cmc":"1,2 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Pojemność\nZakres:\n11 µF do 11 mF CMC 0,55 %\n11 mF do 33 mF CMC 0,85 %\n33 mF do 110 mF CMC 1,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/5\nLMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0","norm_bases":["LMEEiO/5","LMEEiO/2","EURAMET cg-15 v. 3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Pojemność","regulatory_area_en":"Capacitance","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Multimetry Wzorcowanie — Pojemność\nZakres:\n11 µF do 11 mF CMC 0,55 %\n11 mF do 33 mF CMC 0,85 %\n33 mF do 110 mF CMC 1,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/5\nLMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0 Multimetry Wzorcowanie — Pojemnosc\nZakres:\n11 µF do 11 mF CMC 0,55 %\n11 mF do 33 mF CMC 0,85 %\n33 mF do 110 mF CMC 1,2 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/5\nLMEEiO/2 w oparciu o EURAMET cg-15 v. 3.0","search_en":"Multimeters Calibration — Capacitance Internal procedure; Direct method; At permanent location (S) and outside of it (P) Capacitance Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/5 LMEEiO/2 based on EURAMET cg-15 v. 3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":28,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/5\nLMEEiO/2 based on EURAMET cg-15 v. 3.0","methodology_de":"Kalibrierung — Kapazität","parameters_de":[{"name":"","range":"11 µF to 11 mF","cmc":"0,55 %"},{"name":"","range":"11 mF to 33 mF","cmc":"0,85 %"},{"name":"","range":"33 mF to 110 mF","cmc":"1,2 %"}],"reference_de":"LMEEiO/5\nLMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0","regulatory_area_de":"Kapazität","search_de":"Multimeter Kalibrierung — Kapazität Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Kapazität Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/5 LMEEiO/2 auf Grundlage von EURAMET cg-15 v. 3.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Multimeter","methodology_zh":"校准 — 电容","parameters_zh":[{"name":"","range":"11 µF to 11 mF","cmc":"0,55 %"},{"name":"","range":"11 mF to 33 mF","cmc":"0,85 %"},{"name":"","range":"33 mF to 110 mF","cmc":"1,2 %"}],"reference_zh":"LMEEiO/5\nLMEEiO/2 依据EURAMET cg-15 v. 3.0","regulatory_area_zh":"容量","search_zh":"万用表 校准 — 电容 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 容量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/5 LMEEiO/2 依据EURAMET cg-15 v. 3.0","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"万用表","methodology_cs":"Kalibrace — Kapacita","parameters_cs":[{"name":"","range":"11 µF to 11 mF","cmc":"0,55 %"},{"name":"","range":"11 mF to 33 mF","cmc":"0,85 %"},{"name":"","range":"33 mF to 110 mF","cmc":"1,2 %"}],"reference_cs":"LMEEiO/5\nLMEEiO/2 na základě EURAMET cg-15 v. 3.0","regulatory_area_cs":"Objem","search_cs":"Multimetry Kalibrace — Kapacita Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Objem Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/5 LMEEiO/2 na základě EURAMET cg-15 v. 3.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Multimetry"},{"_id":"4aad084e35488ee479032a10","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory parametrów i uszkodzeń linii","test_object_en":"Line parameter and fault analysers","methodology":"Wzorcowanie — Pojemność","methodology_en":"Calibration — Capacitance","parameters":[{"name":"","range":"50 nF do 9 µF","cmc":"0,1 %"}],"parameters_en":[{"name":"","range":"50 nF to 9 µF","cmc":"0,1 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Pojemność\n50 nF do 9 µF CMC 0,1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/42","norm_bases":["LMEEiO/42"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Pojemność","regulatory_area_en":"Capacitance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Analizatory parametrów i uszkodzeń linii Wzorcowanie — Pojemność\n50 nF do 9 µF CMC 0,1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/42 Analizatory parametrow i uszkodzen linii Wzorcowanie — Pojemnosc\n50 nF do 9 µF CMC 0,1 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/42","search_en":"Line parameter and fault analysers Calibration — Capacitance Internal procedure; Direct method; At permanent location (S) Capacitance Internal procedure Direct method At permanent location (S) LMEEiO/42","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":29,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Kapazität","parameters_de":[{"name":"","range":"50 nF to 9 µF","cmc":"0,1 %"}],"regulatory_area_de":"Kapazität","search_de":"Leitungsparameter- und Fehleranalysatoren Kalibrierung — Kapazität Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Kapazität Internes Verfahren Direktes Verfahren Am festen Standort (S) LMEEiO/42","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Leitungsparameter- und Fehleranalysatoren","methodology_zh":"校准 — 电容","parameters_zh":[{"name":"","range":"50 nF to 9 µF","cmc":"0,1 %"}],"regulatory_area_zh":"容量","search_zh":"线路参数与故障分析仪 校准 — 电容 内部程序；直接法；在固定地点 (S) 容量 内部程序 直接法 在固定地点 (S) LMEEiO/42","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"线路参数与故障分析仪","methodology_cs":"Kalibrace — Kapacita","parameters_cs":[{"name":"","range":"50 nF to 9 µF","cmc":"0,1 %"}],"regulatory_area_cs":"Objem","search_cs":"Analyzátory parametrů a poruch vedení Kalibrace — Kapacita Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Objem Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LMEEiO/42","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analyzátory parametrů a poruch vedení"},{"_id":"b9d565e2c0fd3aa3f8bc2e2f","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Oscyloskopy\nSkopometry\nKarty pomiarowe\nSondy pomiarowe","test_object_en":"Oscilloscopes\nScopemeters\nData acquisition cards\nMeasuring probes","methodology":"Wzorcowanie — Pojemność","methodology_en":"Calibration — Capacitance","parameters":[{"name":"","range":"1 pF do 35 pF","cmc":"2 % + 0,25 pF"},{"name":"","range":"35 pF do 120 pF","cmc":"2,5 % + 0,25 pF"}],"parameters_en":[{"name":"","range":"1 pF to 35 pF","cmc":"2 % + 0,25 pF"},{"name":"","range":"35 pF to 120 pF","cmc":"2,5 % + 0,25 pF"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Pojemność\nZakres:\n1 pF do 35 pF CMC 2 % + 0,25 pF\n35 pF do 120 pF CMC 2,5 % + 0,25 pF\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/13 w oparciu o EURAMET cg-7 v. 1.0","norm_bases":["LMEEiO/13","EURAMET cg-7 v. 1.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Pojemność","regulatory_area_en":"Capacitance","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Oscyloskopy\nSkopometry\nKarty pomiarowe\nSondy pomiarowe Wzorcowanie — Pojemność\nZakres:\n1 pF do 35 pF CMC 2 % + 0,25 pF\n35 pF do 120 pF CMC 2,5 % + 0,25 pF\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/13 w oparciu o EURAMET cg-7 v. 1.0 Oscyloskopy\nSkopometry\nKarty pomiarowe\nSondy pomiarowe Wzorcowanie — Pojemnosc\nZakres:\n1 pF do 35 pF CMC 2 % + 0,25 pF\n35 pF do 120 pF CMC 2,5 % + 0,25 pF\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/13 w oparciu o EURAMET cg-7 v. 1.0","search_en":"Oscilloscopes Scopemeters Data acquisition cards Measuring probes Calibration — Capacitance Internal procedure; Direct method; At permanent location (S) and outside of it (P) Capacitance Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/13 based on EURAMET cg-7 v. 1.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":30,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/13 based on EURAMET cg-7 v. 1.0","methodology_de":"Kalibrierung — Kapazität","parameters_de":[{"name":"","range":"1 pF to 35 pF","cmc":"2 % + 0,25 pF"},{"name":"","range":"35 pF to 120 pF","cmc":"2,5 % + 0,25 pF"}],"reference_de":"LMEEiO/13 auf Grundlage von EURAMET cg-7 v. 1.0","regulatory_area_de":"Kapazität","search_de":"Oszilloskope Scopemeter Messkarten Messsonden Kalibrierung — Kapazität Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Kapazität Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/13 auf Grundlage von EURAMET cg-7 v. 1.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Oszilloskope\nScopemeter\nMesskarten\nMesssonden","methodology_zh":"校准 — 电容","parameters_zh":[{"name":"","range":"1 pF to 35 pF","cmc":"2 % + 0,25 pF"},{"name":"","range":"35 pF to 120 pF","cmc":"2,5 % + 0,25 pF"}],"reference_zh":"LMEEiO/13 依据EURAMET cg-7 v. 1.0","regulatory_area_zh":"容量","search_zh":"示波器 手持示波表 测量卡 测量探头 校准 — 电容 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 容量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/13 依据EURAMET cg-7 v. 1.0","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"示波器\n手持示波表\n测量卡\n测量探头","methodology_cs":"Kalibrace — Kapacita","parameters_cs":[{"name":"","range":"1 pF to 35 pF","cmc":"2 % + 0,25 pF"},{"name":"","range":"35 pF to 120 pF","cmc":"2,5 % + 0,25 pF"}],"reference_cs":"LMEEiO/13 na základě EURAMET cg-7 v. 1.0","regulatory_area_cs":"Objem","search_cs":"Osciloskopy Skopmetry Měřicí karty Měřicí sondy Kalibrace — Kapacita Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Objem Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/13 na základě EURAMET cg-7 v. 1.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Osciloskopy\nSkopmetry\nMěřicí karty\nMěřicí sondy"},{"_id":"ca9931d61be7af96194d81fa","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki mocy\nAnalizatory","test_object_en":"Power meters\nAnalysers","methodology":"Wzorcowanie — Kąt przesunięcia fazowego","methodology_en":"Calibration — Phase angle","parameters":[{"name":"f = 50 Hz do 60 Hz; 0,1 A do 20 A; 1 V do 600 V","range":"-90° do 90°","cmc":"0,02°"},{"name":"f = 50 Hz do 60 Hz; 0,1 A do 20 A; 1 V do 600 V; współczynnik mocy cosφ","range":"-1,0 do -0,5 i 0,5 do 1,0","cmc":"0,04 %"},{"name":"f = 50 Hz do 60 Hz; 0,1 A do 20 A; 1 V do 600 V; współczynnik mocy cosφ","range":"-0,5 do 0,5","cmc":"0,2 %"}],"parameters_en":[{"name":"f = 50 Hz to 60 Hz; 0,1 A to 20 A; 1 V to 600 V","range":"-90° to 90°","cmc":"0,02°"},{"name":"f = 50 Hz to 60 Hz; 0,1 A to 20 A; 1 V to 600 V; power factor cosφ","range":"-1,0 to -0,5 and 0,5 to 1,0","cmc":"0,04 %"},{"name":"f = 50 Hz to 60 Hz; 0,1 A to 20 A; 1 V to 600 V; power factor cosφ","range":"-0,5 to 0,5","cmc":"0,2 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt przesunięcia fazowego\nZakres:\nf = 50 Hz do 60 Hz; 0,1 A do 20 A; 1 V do 600 V -90° do 90° CMC 0,02°\nf = 50 Hz do 60 Hz; 0,1 A do 20 A; 1 V do 600 V; współczynnik mocy cosφ -1,0 do -0,5 i 0,5 do 1,0 CMC 0,04 %\nf = 50 Hz do 60 Hz; 0,1 A do 20 A; 1 V do 600 V; współczynnik mocy cosφ -0,5 do 0,5 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/46","norm_bases":["LMEEiO/46"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt przesunięcia fazowego","regulatory_area_en":"Phase angle","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy\nAnalizatory Wzorcowanie — Kąt przesunięcia fazowego\nZakres:\nf = 50 Hz do 60 Hz; 0,1 A do 20 A; 1 V do 600 V -90° do 90° CMC 0,02°\nf = 50 Hz do 60 Hz; 0,1 A do 20 A; 1 V do 600 V; współczynnik mocy cosφ -1,0 do -0,5 i 0,5 do 1,0 CMC 0,04 %\nf = 50 Hz do 60 Hz; 0,1 A do 20 A; 1 V do 600 V; współczynnik mocy cosφ -0,5 do 0,5 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/46 Mierniki mocy\nAnalizatory Wzorcowanie — Kat przesuniecia fazowego\nZakres:\nf = 50 Hz do 60 Hz; 0,1 A do 20 A; 1 V do 600 V -90° do 90° CMC 0,02°\nf = 50 Hz do 60 Hz; 0,1 A do 20 A; 1 V do 600 V; wspolczynnik mocy cosφ -1,0 do -0,5 i 0,5 do 1,0 CMC 0,04 %\nf = 50 Hz do 60 Hz; 0,1 A do 20 A; 1 V do 600 V; wspolczynnik mocy cosφ -0,5 do 0,5 CMC 0,2 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/46","search_en":"Power meters Analysers Calibration — Phase angle Internal procedure; Direct method; At permanent location (S) and outside of it (P) Phase angle Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 Hz to 60 Hz; 0,1 A to 20 A; 1 V to 600 V f = 50 Hz to 60 Hz; 0,1 A to 20 A; 1 V to 600 V; power factor cosφ f = 50 Hz to 60 Hz; 0,1 A to 20 A; 1 V to 600 V; power factor cosφ LMEEiO/46","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":31,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Phasenverschiebungswinkel","parameters_de":[{"name":"f = 50 Hz bis 60 Hz; 0,1 A bis 20 A; 1 V bis 600 V","range":"-90° to 90°","cmc":"0,02°"},{"name":"f = 50 Hz bis 60 Hz; 0,1 A bis 20 A; 1 V bis 600 V; Leistungsfaktor cosφ","range":"-1,0 to -0,5 and 0,5 to 1,0","cmc":"0,04 %"},{"name":"f = 50 Hz bis 60 Hz; 0,1 A bis 20 A; 1 V bis 600 V; Leistungsfaktor cosφ","range":"-0,5 to 0,5","cmc":"0,2 %"}],"regulatory_area_de":"Phasenverschiebungswinkel","search_de":"Leistungsmesser Analysatoren Kalibrierung — Phasenverschiebungswinkel Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Phasenverschiebungswinkel Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 Hz bis 60 Hz; 0,1 A bis 20 A; 1 V bis 600 V f = 50 Hz bis 60 Hz; 0,1 A bis 20 A; 1 V bis 600 V; Leistungsfaktor cosφ f = 50 Hz bis 60 Hz; 0,1 A bis 20 A; 1 V bis 600 V; Leistungsfaktor cosφ LMEEiO/46","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Leistungsmesser\nAnalysatoren","methodology_zh":"校准 — 相位角","parameters_zh":[{"name":"f = 50 Hz 至 60 Hz; 0,1 A 至 20 A; 1 V 至 600 V","range":"-90° to 90°","cmc":"0,02°"},{"name":"f = 50 Hz 至 60 Hz; 0,1 A 至 20 A; 1 V 至 600 V; 功率因数 cosφ","range":"-1,0 to -0,5 and 0,5 to 1,0","cmc":"0,04 %"},{"name":"f = 50 Hz 至 60 Hz; 0,1 A 至 20 A; 1 V 至 600 V; 功率因数 cosφ","range":"-0,5 to 0,5","cmc":"0,2 %"}],"regulatory_area_zh":"相位角","search_zh":"功率计 分析仪 校准 — 相位角 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 相位角 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 Hz 至 60 Hz; 0,1 A 至 20 A; 1 V 至 600 V f = 50 Hz 至 60 Hz; 0,1 A 至 20 A; 1 V 至 600 V; 功率因数 cosφ f = 50 Hz 至 60 Hz; 0,1 A 至 20 A; 1 V 至 600 V; 功率因数 cosφ LMEEiO/46","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"功率计\n分析仪","methodology_cs":"Kalibrace — Fázový úhel","parameters_cs":[{"name":"f = 50 Hz až 60 Hz; 0,1 A až 20 A; 1 V až 600 V","range":"-90° to 90°","cmc":"0,02°"},{"name":"f = 50 Hz až 60 Hz; 0,1 A až 20 A; 1 V až 600 V; účiník cosφ","range":"-1,0 to -0,5 and 0,5 to 1,0","cmc":"0,04 %"},{"name":"f = 50 Hz až 60 Hz; 0,1 A až 20 A; 1 V až 600 V; účiník cosφ","range":"-0,5 to 0,5","cmc":"0,2 %"}],"regulatory_area_cs":"Fázový úhel","search_cs":"Měřiče výkonu Analyzátory Kalibrace — Fázový úhel Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Fázový úhel Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 Hz až 60 Hz; 0,1 A až 20 A; 1 V až 600 V f = 50 Hz až 60 Hz; 0,1 A až 20 A; 1 V až 600 V; účiník cosφ f = 50 Hz až 60 Hz; 0,1 A až 20 A; 1 V až 600 V; účiník cosφ LMEEiO/46","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče výkonu\nAnalyzátory"},{"_id":"17c80c22a6ed50cb8ce2fafb","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Liczniki energii czynnej prądu przemiennego\nAnalizatory mocy\nMierniki mocy\nAnalizatory jakości energii","test_object_en":"AC active energy meters\nPower analysers\nPower meters\nPower quality analysers","methodology":"Wzorcowanie — Energia","methodology_en":"Calibration — Energy","parameters":[{"name":"f = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 do 20 A","range":"|cosφ| = 1 do 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 do 20 A","range":"|cosφ| = 0,5 do 0,1","cmc":"0,1 %"}],"parameters_en":[{"name":"f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 to 20 A","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 to 20 A","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Energia\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 do 20 A |cosφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 do 20 A |cosφ| = 0,5 do 0,1 CMC 0,1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/46","norm_bases":["LMEEiO/46"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Energia","regulatory_area_en":"Energy","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Liczniki energii czynnej prądu przemiennego\nAnalizatory mocy\nMierniki mocy\nAnalizatory jakości energii Wzorcowanie — Energia\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 do 20 A |cosφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 do 20 A |cosφ| = 0,5 do 0,1 CMC 0,1 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/46 Liczniki energii czynnej pradu przemiennego\nAnalizatory mocy\nMierniki mocy\nAnalizatory jakosci energii Wzorcowanie — Energia\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 do 20 A |cosφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 do 20 A |cosφ| = 0,5 do 0,1 CMC 0,1 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/46","search_en":"AC active energy meters Power analysers Power meters Power quality analysers Calibration — Energy Internal procedure; Direct method; At permanent location (S) and outside of it (P) Energy Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 to 20 A f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 to 20 A LMEEiO/46","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":32,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Energie","parameters_de":[{"name":"f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 bis 20 A","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 bis 20 A","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"}],"regulatory_area_de":"Energie","search_de":"Wechselstrom-Wirkenergiezähler Leistungsanalysatoren Leistungsmesser Netzqualitätsanalysatoren Kalibrierung — Energie Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Energie Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 bis 20 A f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 bis 20 A LMEEiO/46","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Wechselstrom-Wirkenergiezähler\nLeistungsanalysatoren\nLeistungsmesser\nNetzqualitätsanalysatoren","methodology_zh":"校准 — 能量","parameters_zh":[{"name":"f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 至 20 A","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 至 20 A","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"}],"regulatory_area_zh":"能量","search_zh":"交流有功电能表 功率分析仪 功率计 电能质量分析仪 校准 — 能量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 能量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 至 20 A f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 至 20 A LMEEiO/46","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"交流有功电能表\n功率分析仪\n功率计\n电能质量分析仪","methodology_cs":"Kalibrace — Energie","parameters_cs":[{"name":"f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 až 20 A","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 až 20 A","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"}],"regulatory_area_cs":"Energie","search_cs":"Elektroměry činné energie střídavého proudu Analyzátory výkonu Měřiče výkonu Analyzátory kvality elektrické energie Kalibrace — Energie Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Energie Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 až 20 A f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 až 20 A LMEEiO/46","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Elektroměry činné energie střídavého proudu\nAnalyzátory výkonu\nMěřiče výkonu\nAnalyzátory kvality elektrické energie"},{"_id":"7a7939829effee9474b9b942","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki mocy DC\nObciążenia elektroniczne","test_object_en":"DC power meters\nElectronic loads","methodology":"Wzorcowanie — Moc DC","methodology_en":"Calibration — DC power","parameters":[{"name":"","range":"5 mW do 10 kW","cmc":"0,05 %"}],"parameters_en":[{"name":"","range":"5 mW to 10 kW","cmc":"0,05 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moc DC\n5 mW do 10 kW CMC 0,05 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/46\nLMEEiO/53","norm_bases":["LMEEiO/46","LMEEiO/53"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moc DC","regulatory_area_en":"DC power","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy DC\nObciążenia elektroniczne Wzorcowanie — Moc DC\n5 mW do 10 kW CMC 0,05 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/46\nLMEEiO/53 Mierniki mocy DC\nObciazenia elektroniczne Wzorcowanie — Moc DC\n5 mW do 10 kW CMC 0,05 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/46\nLMEEiO/53","search_en":"DC power meters Electronic loads Calibration — DC power Internal procedure; Direct method; At permanent location (S) and outside of it (P) DC power Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/46 LMEEiO/53","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":33,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Leistung","parameters_de":[{"name":"","range":"5 mW to 10 kW","cmc":"0,05 %"}],"regulatory_area_de":"DC-Leistung","search_de":"DC-Leistungsmesser Elektronische Lasten Kalibrierung — DC-Leistung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Leistung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/46 LMEEiO/53","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"DC-Leistungsmesser\nElektronische Lasten","methodology_zh":"校准 — 直流功率","parameters_zh":[{"name":"","range":"5 mW to 10 kW","cmc":"0,05 %"}],"regulatory_area_zh":"直流功率","search_zh":"直流功率计 电子负载 校准 — 直流功率 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 直流功率 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/46 LMEEiO/53","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"直流功率计\n电子负载","methodology_cs":"Kalibrace — Stejnosměrný výkon","parameters_cs":[{"name":"","range":"5 mW to 10 kW","cmc":"0,05 %"}],"regulatory_area_cs":"Stejnosměrný výkon","search_cs":"Měřiče stejnosměrného výkonu Elektronické zátěže Kalibrace — Stejnosměrný výkon Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Stejnosměrný výkon Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/46 LMEEiO/53","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče stejnosměrného výkonu\nElektronické zátěže"},{"_id":"3fb25831b5b27b5b7d03fafa","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki mocy czynnej AC\nWatomierze","test_object_en":"AC active power meters\nWattmeters","methodology":"Wzorcowanie — Moc AC","methodology_en":"Calibration — AC power","parameters":[{"name":"f = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 W do 12 kW","range":"|cosφ| = 1 do 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 W do 12 kW","range":"|cosφ| = 0,5 do 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A","range":"|cosφ| = 1 do 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A","range":"|cosφ| = 0,9 do 0,1","cmc":"0,2 %"}],"parameters_en":[{"name":"f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 3 W to 12 kW","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 3 W to 12 kW","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 W do 12 kW |cosφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 W do 12 kW |cosφ| = 0,5 do 0,1 CMC 0,1 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/46\nLMEEiO/53","norm_bases":["LMEEiO/46","LMEEiO/53"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moc AC","regulatory_area_en":"AC power","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy czynnej AC\nWatomierze Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 W do 12 kW |cosφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 W do 12 kW |cosφ| = 0,5 do 0,1 CMC 0,1 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/46\nLMEEiO/53 Mierniki mocy czynnej AC\nWatomierze Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 W do 12 kW |cosφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 W do 12 kW |cosφ| = 0,5 do 0,1 CMC 0,1 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/46\nLMEEiO/53","search_en":"AC active power meters Wattmeters Calibration — AC power Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC power Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 3 W to 12 kW f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 3 W to 12 kW f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A LMEEiO/46 LMEEiO/53","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":34,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — AC-Leistung","parameters_de":[{"name":"f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 3 W bis 12 kW","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 3 W bis 12 kW","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_de":"AC-Leistung","search_de":"AC-Wirkleistungsmesser Wattmeter Kalibrierung — AC-Leistung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Leistung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 3 W bis 12 kW f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 3 W bis 12 kW f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A LMEEiO/46 LMEEiO/53","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"AC-Wirkleistungsmesser\nWattmeter","methodology_zh":"校准 — 交流功率","parameters_zh":[{"name":"f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 3 W 至 12 kW","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 3 W 至 12 kW","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_zh":"交流功率","search_zh":"交流有功功率计 功率表 校准 — 交流功率 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流功率 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 3 W 至 12 kW f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 3 W 至 12 kW f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A LMEEiO/46 LMEEiO/53","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"交流有功功率计\n功率表","methodology_cs":"Kalibrace — Výkon AC","parameters_cs":[{"name":"f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 3 W až 12 kW","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 3 W až 12 kW","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_cs":"Výkon AC","search_cs":"Měřiče střídavého činného výkonu Wattmetry Kalibrace — Výkon AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Výkon AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 3 W až 12 kW f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 3 W až 12 kW f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A LMEEiO/46 LMEEiO/53","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče střídavého činného výkonu\nWattmetry"},{"_id":"857d69414fbdfb07f2de87af","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki mocy biernej AC\nWaromierze","test_object_en":"AC reactive power meters\nVarmeters","methodology":"Wzorcowanie — Moc AC","methodology_en":"Calibration — AC power","parameters":[{"name":"f = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 var do 12 kvar","range":"|sinφ| = 1 do 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 var do 12 kvar","range":"|sinφ| = 0,5 do 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A","range":"|sinφ| = 1 do 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A","range":"|sinφ| = 0,9 do 0,1","cmc":"0,2 %"}],"parameters_en":[{"name":"f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 3 var to 12 kvar","range":"|sinφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 3 var to 12 kvar","range":"|sinφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz to 60 Hz; 1 V to 560 V,; 5 mA to 0,1 A i 20 A to 100 A","range":"|sinφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz to 60 Hz; 1 V to 560 V,; 5 mA to 0,1 A i 20 A to 100 A","range":"|sinφ| = 0,9 to 0,1","cmc":"0,2 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 var do 12 kvar |sinφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 var do 12 kvar |sinφ| = 0,5 do 0,1 CMC 0,1 %\nf = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A |sinφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A |sinφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/46\nLMEEiO/53","norm_bases":["LMEEiO/46","LMEEiO/53"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moc AC","regulatory_area_en":"AC power","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy biernej AC\nWaromierze Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 var do 12 kvar |sinφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 var do 12 kvar |sinφ| = 0,5 do 0,1 CMC 0,1 %\nf = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A |sinφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A |sinφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/46\nLMEEiO/53 Mierniki mocy biernej AC\nWaromierze Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 var do 12 kvar |sinφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 3 var do 12 kvar |sinφ| = 0,5 do 0,1 CMC 0,1 %\nf = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A |sinφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A |sinφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/46\nLMEEiO/53","search_en":"AC reactive power meters Varmeters Calibration — AC power Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC power Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 3 var to 12 kvar f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 3 var to 12 kvar f = 50 Hz to 60 Hz; 1 V to 560 V,; 5 mA to 0,1 A i 20 A to 100 A f = 50 Hz to 60 Hz; 1 V to 560 V,; 5 mA to 0,1 A i 20 A to 100 A LMEEiO/46 LMEEiO/53","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":35,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — AC-Leistung","parameters_de":[{"name":"f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 3 var bis 12 kvar","range":"|sinφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 3 var bis 12 kvar","range":"|sinφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz bis 60 Hz; 1 V bis 560 V,; 5 mA bis 0,1 A und 20 A bis 100 A","range":"|sinφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz bis 60 Hz; 1 V bis 560 V,; 5 mA bis 0,1 A und 20 A bis 100 A","range":"|sinφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_de":"AC-Leistung","search_de":"AC-Blindleistungsmesser Varmeter Kalibrierung — AC-Leistung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Leistung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 3 var bis 12 kvar f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 3 var bis 12 kvar f = 50 Hz bis 60 Hz; 1 V bis 560 V,; 5 mA bis 0,1 A und 20 A bis 100 A f = 50 Hz bis 60 Hz; 1 V bis 560 V,; 5 mA bis 0,1 A und 20 A bis 100 A LMEEiO/46 LMEEiO/53","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"AC-Blindleistungsmesser\nVarmeter","methodology_zh":"校准 — 交流功率","parameters_zh":[{"name":"f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 3 var 至 12 kvar","range":"|sinφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 3 var 至 12 kvar","range":"|sinφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz 至 60 Hz; 1 V 至 560 V,; 5 mA 至 0,1 A 和 20 A 至 100 A","range":"|sinφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz 至 60 Hz; 1 V 至 560 V,; 5 mA 至 0,1 A 和 20 A 至 100 A","range":"|sinφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_zh":"交流功率","search_zh":"交流无功功率计 无功功率表 校准 — 交流功率 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流功率 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 3 var 至 12 kvar f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 3 var 至 12 kvar f = 50 Hz 至 60 Hz; 1 V 至 560 V,; 5 mA 至 0,1 A 和 20 A 至 100 A f = 50 Hz 至 60 Hz; 1 V 至 560 V,; 5 mA 至 0,1 A 和 20 A 至 100 A LMEEiO/46 LMEEiO/53","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"交流无功功率计\n无功功率表","methodology_cs":"Kalibrace — Výkon AC","parameters_cs":[{"name":"f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 3 var až 12 kvar","range":"|sinφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 3 var až 12 kvar","range":"|sinφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz až 60 Hz; 1 V až 560 V,; 5 mA až 0,1 A a 20 A až 100 A","range":"|sinφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz až 60 Hz; 1 V až 560 V,; 5 mA až 0,1 A a 20 A až 100 A","range":"|sinφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_cs":"Výkon AC","search_cs":"Měřiče střídavého jalového výkonu Varmetry Kalibrace — Výkon AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Výkon AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 3 var až 12 kvar f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 3 var až 12 kvar f = 50 Hz až 60 Hz; 1 V až 560 V,; 5 mA až 0,1 A a 20 A až 100 A f = 50 Hz až 60 Hz; 1 V až 560 V,; 5 mA až 0,1 A a 20 A až 100 A LMEEiO/46 LMEEiO/53","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče střídavého jalového výkonu\nVarmetry"},{"_id":"8711a3542ec0b1f577231e1d","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki mocy pozornej AC","test_object_en":"AC apparent power meters","methodology":"Wzorcowanie — Moc AC","methodology_en":"Calibration — AC power","parameters":[{"name":"f = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A","range":"3 VA do 12 kVA","cmc":"0,04 %"},{"name":"f = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A","range":"|cosφ| = 1 do 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A","range":"|cosφ| = 0,9 do 0,1","cmc":"0,2 %"}],"parameters_en":[{"name":"f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A","range":"3 VA to 12 kVA","cmc":"0,04 %"},{"name":"f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A 3 VA do 12 kVA CMC 0,04 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/46\nLMEEiO/53","norm_bases":["LMEEiO/46","LMEEiO/53"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moc AC","regulatory_area_en":"AC power","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy pozornej AC Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A 3 VA do 12 kVA CMC 0,04 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/46\nLMEEiO/53 Mierniki mocy pozornej AC Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A 3 VA do 12 kVA CMC 0,04 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/46\nLMEEiO/53","search_en":"AC apparent power meters Calibration — AC power Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC power Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A LMEEiO/46 LMEEiO/53","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":36,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — AC-Leistung","parameters_de":[{"name":"f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A","range":"3 VA to 12 kVA","cmc":"0,04 %"},{"name":"f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_de":"AC-Leistung","search_de":"AC-Scheinleistungsmesser Kalibrierung — AC-Leistung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Leistung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A LMEEiO/46 LMEEiO/53","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"AC-Scheinleistungsmesser","methodology_zh":"校准 — 交流功率","parameters_zh":[{"name":"f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A","range":"3 VA to 12 kVA","cmc":"0,04 %"},{"name":"f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_zh":"交流功率","search_zh":"交流视在功率计 校准 — 交流功率 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流功率 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A LMEEiO/46 LMEEiO/53","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"交流视在功率计","methodology_cs":"Kalibrace — Výkon AC","parameters_cs":[{"name":"f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A","range":"3 VA to 12 kVA","cmc":"0,04 %"},{"name":"f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_cs":"Výkon AC","search_cs":"Měřiče střídavého zdánlivého výkonu Kalibrace — Výkon AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Výkon AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A LMEEiO/46 LMEEiO/53","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče střídavého zdánlivého výkonu"},{"_id":"712ae8c17d9200b3ef900783","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki mocy czynnej AC w systemie trójfazowym","test_object_en":"Three-phase AC active power meters","methodology":"Wzorcowanie — Moc AC","methodology_en":"Calibration — AC power","parameters":[{"name":"f = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 W do 36 kW","range":"|cosφ| = 1 do 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 W do 36 kW","range":"|cosφ| = 0,5 do 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A","range":"|cosφ| = 1 do 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A","range":"|cosφ| = 0,9 do 0,1","cmc":"0,2 %"}],"parameters_en":[{"name":"f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 9 W to 36 kW","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 9 W to 36 kW","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 W do 36 kW |cosφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 W do 36 kW |cosφ| = 0,5 do 0,1 CMC 0,1 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/46\nLMEEiO/53","norm_bases":["LMEEiO/46","LMEEiO/53"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moc AC","regulatory_area_en":"AC power","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy czynnej AC w systemie trójfazowym Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 W do 36 kW |cosφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 W do 36 kW |cosφ| = 0,5 do 0,1 CMC 0,1 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/46\nLMEEiO/53 Mierniki mocy czynnej AC w systemie trojfazowym Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 W do 36 kW |cosφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 W do 36 kW |cosφ| = 0,5 do 0,1 CMC 0,1 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/46\nLMEEiO/53","search_en":"Three-phase AC active power meters Calibration — AC power Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC power Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 9 W to 36 kW f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 9 W to 36 kW f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A LMEEiO/46 LMEEiO/53","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":37,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — AC-Leistung","parameters_de":[{"name":"f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 9 W bis 36 kW","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 9 W bis 36 kW","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_de":"AC-Leistung","search_de":"AC-Wirkleistungsmesser im Drehstromsystem Kalibrierung — AC-Leistung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Leistung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 9 W bis 36 kW f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 9 W bis 36 kW f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A LMEEiO/46 LMEEiO/53","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"AC-Wirkleistungsmesser im Drehstromsystem","methodology_zh":"校准 — 交流功率","parameters_zh":[{"name":"f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 9 W 至 36 kW","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 9 W 至 36 kW","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_zh":"交流功率","search_zh":"三相交流有功功率计 校准 — 交流功率 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流功率 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 9 W 至 36 kW f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 9 W 至 36 kW f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A LMEEiO/46 LMEEiO/53","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"三相交流有功功率计","methodology_cs":"Kalibrace — Výkon AC","parameters_cs":[{"name":"f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 9 W až 36 kW","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 9 W až 36 kW","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_cs":"Výkon AC","search_cs":"Měřiče střídavého činného výkonu v trojfázové soustavě Kalibrace — Výkon AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Výkon AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 9 W až 36 kW f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 9 W až 36 kW f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A LMEEiO/46 LMEEiO/53","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče střídavého činného výkonu v trojfázové soustavě"},{"_id":"cc707e9cc97d99a1c72917d5","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki mocy biernej AC w systemie trójfazowym","test_object_en":"Three-phase AC reactive power meters","methodology":"Wzorcowanie — Moc AC","methodology_en":"Calibration — AC power","parameters":[{"name":"f = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 var do 36 kvar","range":"|cosφ| = 1 do 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 var do 36 kvar","range":"|cosφ| = 0,5 do 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A","range":"|cosφ| = 1 do 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A","range":"|cosφ| = 0,9 do 0,1","cmc":"0,2 %"}],"parameters_en":[{"name":"f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 9 var to 36 kvar","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 9 var to 36 kvar","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 var do 36 kvar |cosφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 var do 36 kvar |cosφ| = 0,5 do 0,1 CMC 0,1 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/46\nLMEEiO/53","norm_bases":["LMEEiO/46","LMEEiO/53"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moc AC","regulatory_area_en":"AC power","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy biernej AC w systemie trójfazowym Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 var do 36 kvar |cosφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 var do 36 kvar |cosφ| = 0,5 do 0,1 CMC 0,1 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/46\nLMEEiO/53 Mierniki mocy biernej AC w systemie trojfazowym Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 var do 36 kvar |cosφ| = 1 do 0,5 CMC 0,04 %\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A; 9 var do 36 kvar |cosφ| = 0,5 do 0,1 CMC 0,1 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/46\nLMEEiO/53","search_en":"Three-phase AC reactive power meters Calibration — AC power Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC power Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 9 var to 36 kvar f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A; 9 var to 36 kvar f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A f = 50 Hz to 60 Hz; 1 V to 560 V; 5 mA to 0,1 A i 20 A to 100 A LMEEiO/46 LMEEiO/53","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":38,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — AC-Leistung","parameters_de":[{"name":"f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 9 var bis 36 kvar","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 9 var bis 36 kvar","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_de":"AC-Leistung","search_de":"AC-Blindleistungsmesser im Drehstromsystem Kalibrierung — AC-Leistung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Leistung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 9 var bis 36 kvar f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A; 9 var bis 36 kvar f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A f = 50 Hz bis 60 Hz; 1 V bis 560 V; 5 mA bis 0,1 A und 20 A bis 100 A LMEEiO/46 LMEEiO/53","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"AC-Blindleistungsmesser im Drehstromsystem","methodology_zh":"校准 — 交流功率","parameters_zh":[{"name":"f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 9 var 至 36 kvar","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 9 var 至 36 kvar","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_zh":"交流功率","search_zh":"三相交流无功功率计 校准 — 交流功率 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流功率 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 9 var 至 36 kvar f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A; 9 var 至 36 kvar f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A f = 50 Hz 至 60 Hz; 1 V 至 560 V; 5 mA 至 0,1 A 和 20 A 至 100 A LMEEiO/46 LMEEiO/53","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"三相交流无功功率计","methodology_cs":"Kalibrace — Výkon AC","parameters_cs":[{"name":"f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 9 var až 36 kvar","range":"|cosφ| = 1 to 0,5","cmc":"0,04 %"},{"name":"f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 9 var až 36 kvar","range":"|cosφ| = 0,5 to 0,1","cmc":"0,1 %"},{"name":"f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_cs":"Výkon AC","search_cs":"Měřiče střídavého jalového výkonu v trojfázové soustavě Kalibrace — Výkon AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Výkon AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 9 var až 36 kvar f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A; 9 var až 36 kvar f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A f = 50 Hz až 60 Hz; 1 V až 560 V; 5 mA až 0,1 A a 20 A až 100 A LMEEiO/46 LMEEiO/53","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče střídavého jalového výkonu v trojfázové soustavě"},{"_id":"f57693918f6fb94621c9c4e8","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki mocy pozornej AC w systemie trójfazowym","test_object_en":"Three-phase AC apparent power meters","methodology":"Wzorcowanie — Moc AC","methodology_en":"Calibration — AC power","parameters":[{"name":"f = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A","range":"9 VA do 36 kVA","cmc":"0,04 %"},{"name":"f = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A","range":"|cosφ| = 1 do 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A","range":"|cosφ| = 0,9 do 0,1","cmc":"0,2 %"}],"parameters_en":[{"name":"f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A","range":"9 VA to 36 kVA","cmc":"0,04 %"},{"name":"f = 50 Hz to 60 Hz; 1 V to 560 V,; 5 mA to 0,1 A i 20 A to 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz to 60 Hz; 1 V to 560 V,; 5 mA to 0,1 A i 20 A to 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A 9 VA do 36 kVA CMC 0,04 %\nf = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/46\nLMEEiO/53","norm_bases":["LMEEiO/46","LMEEiO/53"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moc AC","regulatory_area_en":"AC power","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy pozornej AC w systemie trójfazowym Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A 9 VA do 36 kVA CMC 0,04 %\nf = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/46\nLMEEiO/53 Mierniki mocy pozornej AC w systemie trojfazowym Wzorcowanie — Moc AC\nZakres:\nf = 50 Hz do 60 Hz; 30 V do 600 V; 0,1 A do 20 A 9 VA do 36 kVA CMC 0,04 %\nf = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 1 do 0,9 CMC 0,05 %\nf = 50 Hz do 60 Hz; 1 V do 560 V,; 5 mA do 0,1 A i 20 A do 100 A |cosφ| = 0,9 do 0,1 CMC 0,2 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/46\nLMEEiO/53","search_en":"Three-phase AC apparent power meters Calibration — AC power Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC power Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 Hz to 60 Hz; 30 V to 600 V; 0,1 A to 20 A f = 50 Hz to 60 Hz; 1 V to 560 V,; 5 mA to 0,1 A i 20 A to 100 A f = 50 Hz to 60 Hz; 1 V to 560 V,; 5 mA to 0,1 A i 20 A to 100 A LMEEiO/46 LMEEiO/53","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":39,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — AC-Leistung","parameters_de":[{"name":"f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A","range":"9 VA to 36 kVA","cmc":"0,04 %"},{"name":"f = 50 Hz bis 60 Hz; 1 V bis 560 V,; 5 mA bis 0,1 A und 20 A bis 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz bis 60 Hz; 1 V bis 560 V,; 5 mA bis 0,1 A und 20 A bis 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_de":"AC-Leistung","search_de":"AC-Scheinleistungsmesser im Drehstromsystem Kalibrierung — AC-Leistung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Leistung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 Hz bis 60 Hz; 30 V bis 600 V; 0,1 A bis 20 A f = 50 Hz bis 60 Hz; 1 V bis 560 V,; 5 mA bis 0,1 A und 20 A bis 100 A f = 50 Hz bis 60 Hz; 1 V bis 560 V,; 5 mA bis 0,1 A und 20 A bis 100 A LMEEiO/46 LMEEiO/53","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"AC-Scheinleistungsmesser im Drehstromsystem","methodology_zh":"校准 — 交流功率","parameters_zh":[{"name":"f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A","range":"9 VA to 36 kVA","cmc":"0,04 %"},{"name":"f = 50 Hz 至 60 Hz; 1 V 至 560 V,; 5 mA 至 0,1 A 和 20 A 至 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz 至 60 Hz; 1 V 至 560 V,; 5 mA 至 0,1 A 和 20 A 至 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_zh":"交流功率","search_zh":"三相交流视在功率计 校准 — 交流功率 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流功率 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 Hz 至 60 Hz; 30 V 至 600 V; 0,1 A 至 20 A f = 50 Hz 至 60 Hz; 1 V 至 560 V,; 5 mA 至 0,1 A 和 20 A 至 100 A f = 50 Hz 至 60 Hz; 1 V 至 560 V,; 5 mA 至 0,1 A 和 20 A 至 100 A LMEEiO/46 LMEEiO/53","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"三相交流视在功率计","methodology_cs":"Kalibrace — Výkon AC","parameters_cs":[{"name":"f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A","range":"9 VA to 36 kVA","cmc":"0,04 %"},{"name":"f = 50 Hz až 60 Hz; 1 V až 560 V,; 5 mA až 0,1 A a 20 A až 100 A","range":"|cosφ| = 1 to 0,9","cmc":"0,05 %"},{"name":"f = 50 Hz až 60 Hz; 1 V až 560 V,; 5 mA až 0,1 A a 20 A až 100 A","range":"|cosφ| = 0,9 to 0,1","cmc":"0,2 %"}],"regulatory_area_cs":"Výkon AC","search_cs":"Měřiče střídavého zdánlivého výkonu v trojfázové soustavě Kalibrace — Výkon AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Výkon AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 Hz až 60 Hz; 30 V až 600 V; 0,1 A až 20 A f = 50 Hz až 60 Hz; 1 V až 560 V,; 5 mA až 0,1 A a 20 A až 100 A f = 50 Hz až 60 Hz; 1 V až 560 V,; 5 mA až 0,1 A a 20 A až 100 A LMEEiO/46 LMEEiO/53","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče střídavého zdánlivého výkonu v trojfázové soustavě"},{"_id":"54792d27edebf59c6e81dab0","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Wskaźniki (mierniki) temperatury (w tym regulatory)\nSymulatory temperaury","test_object_en":"Temperature indicators (meters) (including controllers)\nTemperature simulators","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electrical simulation of quantities","parameters":[{"name":"Symulacja czujnika rezystancyjnego","range":"-200 °C do 850 °C","cmc":"0,005 °C"},{"name":"Symulacja termoelementu","range":"-270 °C do 1820 °C","cmc":"0,03 °C"}],"parameters_en":[{"name":"Simulation of a resistance sensor","range":"-200 °C to 850 °C","cmc":"0,005 °C"},{"name":"Simulation of a thermocouple","range":"-270 °C to 1820 °C","cmc":"0,03 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Indirect method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\nSymulacja czujnika rezystancyjnego -200 °C do 850 °C CMC 0,005 °C\nSymulacja termoelementu -270 °C do 1820 °C CMC 0,03 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/2\nLMEEiO/3","norm_bases":["LMEEiO/2","LMEEiO/3"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electrical simulation of quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Wskaźniki (mierniki) temperatury (w tym regulatory)\nSymulatory temperaury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\nSymulacja czujnika rezystancyjnego -200 °C do 850 °C CMC 0,005 °C\nSymulacja termoelementu -270 °C do 1820 °C CMC 0,03 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/2\nLMEEiO/3 Wskazniki (mierniki) temperatury (w tym regulatory)\nSymulatory temperaury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\nSymulacja czujnika rezystancyjnego -200 °C do 850 °C CMC 0,005 °C\nSymulacja termoelementu -270 °C do 1820 °C CMC 0,03 °C\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/2\nLMEEiO/3","search_en":"Temperature indicators (meters) (including controllers) Temperature simulators Calibration — Electrical simulation of quantities Internal procedure; Indirect method; At permanent location (S) and outside of it (P) Electrical simulation of quantities Internal procedure Indirect method At permanent location (S) and outside of it (P) Simulation of a resistance sensor Simulation of a thermocouple LMEEiO/2 LMEEiO/3","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":40,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"Simulation eines Widerstandsfühlers","range":"-200 °C bis 850 °C","cmc":"0,005 °C"},{"name":"Simulation eines Thermoelements","range":"-270 °C to 1820 °C","cmc":"0,03 °C"}],"regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturanzeiger (-messgeräte) (einschließlich Regler) Temperatursimulatoren Kalibrierung — Elektrische Simulation von Größen Interne Verfahrensanweisung; Indirektes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische Simulation von Größen Internes Verfahren Indirektes Verfahren Am festen Standort (S) und außerhalb (P) Simulation eines Widerstandsfühlers Simulation eines Thermoelements LMEEiO/2 LMEEiO/3","technique_de":"Interne Verfahrensanweisung; Indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Temperaturanzeiger (-messgeräte) (einschließlich Regler)\nTemperatursimulatoren","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"电阻传感器模拟","range":"-200 °C 至 850 °C","cmc":"0,005 °C"},{"name":"热电偶模拟","range":"-270 °C to 1820 °C","cmc":"0,03 °C"}],"regulatory_area_zh":"量值的电模拟","search_zh":"温度指示仪（测量仪）（包括调节器） 温度模拟器 校准 — 物理量的电模拟 内部程序；间接法；在固定地点 (S) 及固定地点以外 (P) 量值的电模拟 内部程序 间接法 在固定地点 (S) 及固定地点以外 (P) 电阻传感器模拟 热电偶模拟 LMEEiO/2 LMEEiO/3","technique_zh":"内部程序；间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"温度指示仪（测量仪）（包括调节器）\n温度模拟器","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"Simulace odporového čidla","range":"-200 °C do 850 °C","cmc":"0,005 °C"},{"name":"Simulace termočlánku","range":"-270 °C to 1820 °C","cmc":"0,03 °C"}],"regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Ukazatele (měřiče) teploty (včetně regulátorů) Simulátory teploty Kalibrace — Elektrická simulace veličin Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Elektrická simulace veličin Vnitřní postup Nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) Simulace odporového čidla Simulace termočlánku LMEEiO/2 LMEEiO/3","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Ukazatele (měřiče) teploty (včetně regulátorů)\nSimulátory teploty"},{"_id":"155ae568eaee72a2aa757c4d","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory\nAnalizatory obwodów\nAnalizatory widma\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\nWzmacniacze\n- poziom mocy wyjściowej","test_object_en":"Generators\nNetwork analysers\nSpectrum analysers\nRadio communication testers\nMeasuring receivers\nAmplifiers\n- output power level","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"f = 10 Hz do 9 kHz","range":"-40 dBm do -30 dBm","cmc":"0,20 dB"},{"name":"f = 10 Hz do 9 kHz","range":"-30 dBm do -20 dBm","cmc":"0,068 dB"},{"name":"f = 10 Hz do 9 kHz","range":"-20 dBm do -10 dBm","cmc":"0,029 dB"},{"name":"f = 10 Hz do 9 kHz","range":"-10 dBm do 0 dBm","cmc":"0,019 dB"},{"name":"f = 10 Hz do 9 kHz","range":"0 dBm do 30 dBm","cmc":"0,024 dB"},{"name":"f = 9 kHz do 20 kHz","range":"-40 dBm do -30 dBm","cmc":"0,14 dB"},{"name":"f = 9 kHz do 20 kHz","range":"-30 dBm do -20 dBm","cmc":"0,057 dB"},{"name":"f = 9 kHz do 20 kHz","range":"-20 dBm do -10 dBm","cmc":"0,029 dB"},{"name":"f = 9 kHz do 20 kHz","range":"-10 dBm do 0 dBm","cmc":"0,019 dB"},{"name":"f = 9 kHz do 20 kHz","range":"0 dBm do 30 dBm","cmc":"0,024 dB"},{"name":"f = 20 kHz do 50 kHz","range":"-40 dBm do -30 dBm","cmc":"0,14 dB"},{"name":"f = 20 kHz do 50 kHz","range":"-30 dBm do -20 dBm","cmc":"0,057 dB"},{"name":"f = 20 kHz do 50 kHz","range":"-20 dBm do -10 dBm","cmc":"0,034 dB"},{"name":"f = 20 kHz do 50 kHz","range":"-10 dBm do 0 dBm","cmc":"0,023 dB"},{"name":"f = 20 kHz do 50 kHz","range":"0 dBm do 30 dBm","cmc":"0,033 dB"},{"name":"f = 50 kHz do 100 kHz","range":"-40 dBm do -30 dBm","cmc":"0,14 dB"},{"name":"f = 50 kHz do 100 kHz","range":"-30 dBm do -20 dBm","cmc":"0,057 dB"},{"name":"f = 50 kHz do 100 kHz","range":"-20 dBm do -10 dBm","cmc":"0,041 dB"},{"name":"f = 50 kHz do 100 kHz","range":"-10 dBm do 0 dBm","cmc":"0,028 dB"},{"name":"f = 50 kHz do 100 kHz","range":"0 dBm do 30 dBm","cmc":"0,052 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-130 dBm do -120 dBm","cmc":"1,2 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-120 dBm do -110 dBm","cmc":"0,57 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-110 dBm do -100 dBm","cmc":"0,23 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-100 dBm do -90 dBm","cmc":"0,11 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-90 dBm do -80 dBm","cmc":"0,10 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-80 dBm do -70 dBm","cmc":"0,097 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-70 dBm do -60 dBm","cmc":"0,093 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-60 dBm do -50 dBm","cmc":"0,067 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-50 dBm do -40 dBm","cmc":"0,065 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-40 dBm do -30 dBm","cmc":"0,062 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-30 dBm do -20 dBm","cmc":"0,057 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-20 dBm do -10 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-10 dBm do 0 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz do 10 MHz","range":"0 dBm do 20 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz do 10 MHz","range":"20 dBm do 30 dBm","cmc":"0,060 dB"},{"name":"f = 100 kHz do 10 MHz","range":"30 dBm do 45 dBm","cmc":"0,18 dB"},{"name":"f = 100 kHz do 10 MHz","range":"45 dBm do 52 dBm","cmc":"0,21 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-130 dBm do -120 dBm","cmc":"0,94 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-120 dBm do -110 dBm","cmc":"0,44 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-110 dBm do -100 dBm","cmc":"0,18 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-100 dBm do -90 dBm","cmc":"0,11 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-90 dBm do -80 dBm","cmc":"0,10 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-80 dBm do -70 dBm","cmc":"0,099 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-70 dBm do -60 dBm","cmc":"0,095 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-60 dBm do -50 dBm","cmc":"0,071 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-50 dBm do -40 dBm","cmc":"0,068 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-40 dBm do -30 dBm","cmc":"0,066 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-30 dBm do -20 dBm","cmc":"0,060 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-20 dBm do -10 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-10 dBm do 0 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"0 dBm do 20 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"20 dBm do 35 dBm","cmc":"0,060 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"35 dBm do 45 dBm","cmc":"0,18 dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"45 dBm do 52 dBm","cmc":"0,21 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-120 dBm do -110 dBm","cmc":"0,82 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-110 dBm do -100 dBm","cmc":"0,37 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-100 dBm do -90 dBm","cmc":"0,16 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-90 dBm do -80 dBm","cmc":"0,10 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-80 dBm do -70 dBm","cmc":"0,097 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-70 dBm do -60 dBm","cmc":"0,093 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-60 dBm do -50 dBm","cmc":"0,089 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-50 dBm do -40 dBm","cmc":"0,065 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-40 dBm do -30 dBm","cmc":"0,062 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-30 dBm do -20 dBm","cmc":"0,057 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-20 dBm do -10 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-10 dBm do 0 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"0 dBm do 20 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"20 dBm do 35 dBm","cmc":"0,058 dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"35 dBm do 44 dBm","cmc":"0,18 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-110 dBm do -100 dBm","cmc":"0,76 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-100 dBm do -90 dBm","cmc":"0,33 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-90 dBm do -80 dBm","cmc":"0,14 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-80 dBm do -70 dBm","cmc":"0,097 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-70 dBm do -60 dBm","cmc":"0,093 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-60 dBm do -50 dBm","cmc":"0,089 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-50 dBm do -40 dBm","cmc":"0,065 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-40 dBm do -30 dBm","cmc":"0,062 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-30 dBm do -20 dBm","cmc":"0,057 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-20 dBm do -10 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-10 dBm do 0 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"0 dBm do 20 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"20 dBm do 30 dBm","cmc":"0,060 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"30 dBm do 35 dBm","cmc":"0,083 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"35 dBm do 44 dBm","cmc":"0,19 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-100 dBm do -90 dBm","cmc":"0,65 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-90 dBm do -80 dBm","cmc":"0,27 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-80 dBm do -70 dBm","cmc":"0,13 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-70 dBm do -60 dBm","cmc":"0,093 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-60 dBm do -50 dBm","cmc":"0,089 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-50 dBm do -40 dBm","cmc":"0,085 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-40 dBm do -30 dBm","cmc":"0,062 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-30 dBm do -20 dBm","cmc":"0,057 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-20 dBm do -10 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-10 dBm do 0 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"0 dBm do 20 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"20 dBm do 30 dBm","cmc":"0,060 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"30 dBm do 35 dBm","cmc":"0,13 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"35 dBm do 44 dBm","cmc":"0,22 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-100 dBm do -90 dBm","cmc":"0,65 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-90 dBm do -80 dBm","cmc":"0,28 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-80 dBm do -70 dBm","cmc":"0,14 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-70 dBm do -60 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-60 dBm do -50 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-50 dBm do -40 dBm","cmc":"0,098 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-40 dBm do -30 dBm","cmc":"0,079 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-30 dBm do -20 dBm","cmc":"0,077 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-20 dBm do -10 dBm","cmc":"0,075 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-10 dBm do 0 dBm","cmc":"0,073 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"0 dBm do 20 dBm","cmc":"0,073 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"20 dBm do 30 dBm","cmc":"0,077 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-100 dBm do -90 dBm","cmc":"1,1 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-90 dBm do -80 dBm","cmc":"0,52 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-80 dBm do -70 dBm","cmc":"0,22 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-70 dBm do -60 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-60 dBm do -50 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-50 dBm do -40 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-40 dBm do -30 dBm","cmc":"0,11 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-30 dBm do -20 dBm","cmc":"0,098 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-20 dBm do -10 dBm","cmc":"0,097 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-10 dBm do 0 dBm","cmc":"0,095 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"0 dBm do 20 dBm","cmc":"0,095 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"20 dBm do 30 dBm","cmc":"0,098 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-80 dBm do -70 dBm","cmc":"0,37 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-70 dBm do -60 dBm","cmc":"0,18 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-60 dBm do -50 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-50 dBm do -40 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-40 dBm do -30 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-30 dBm do -20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-20 dBm do -10 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-10 dBm do 0 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"0 dBm do 20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"20 dBm do 30 dBm","cmc":"0,12 dB"},{"name":"f = 40 GHz do 50 GHz","range":"-40 dBm do -30 dBm","cmc":"0,19 dB"},{"name":"f = 40 GHz do 50 GHz","range":"-30 dBm do -20 dBm","cmc":"0,19 dB"},{"name":"f = 40 GHz do 50 GHz","range":"-20 dBm do -10 dBm","cmc":"0,15 dB"},{"name":"f = 40 GHz do 50 GHz","range":"-10 dBm do 0 dBm","cmc":"0,14 dB"},{"name":"f = 40 GHz do 50 GHz","range":"0 dBm do 20 dBm","cmc":"0,14 dB"}],"parameters_en":[{"name":"f = 10 Hz to 9 kHz","range":"-40 dBm to -30 dBm","cmc":"0,20 dB"},{"name":"f = 10 Hz to 9 kHz","range":"-30 dBm to -20 dBm","cmc":"0,068 dB"},{"name":"f = 10 Hz to 9 kHz","range":"-20 dBm to -10 dBm","cmc":"0,029 dB"},{"name":"f = 10 Hz to 9 kHz","range":"-10 dBm to 0 dBm","cmc":"0,019 dB"},{"name":"f = 10 Hz to 9 kHz","range":"0 dBm to 30 dBm","cmc":"0,024 dB"},{"name":"f = 9 kHz to 20 kHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 9 kHz to 20 kHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 9 kHz to 20 kHz","range":"-20 dBm to -10 dBm","cmc":"0,029 dB"},{"name":"f = 9 kHz to 20 kHz","range":"-10 dBm to 0 dBm","cmc":"0,019 dB"},{"name":"f = 9 kHz to 20 kHz","range":"0 dBm to 30 dBm","cmc":"0,024 dB"},{"name":"f = 20 kHz to 50 kHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 20 kHz to 50 kHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 20 kHz to 50 kHz","range":"-20 dBm to -10 dBm","cmc":"0,034 dB"},{"name":"f = 20 kHz to 50 kHz","range":"-10 dBm to 0 dBm","cmc":"0,023 dB"},{"name":"f = 20 kHz to 50 kHz","range":"0 dBm to 30 dBm","cmc":"0,033 dB"},{"name":"f = 50 kHz to 100 kHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 50 kHz to 100 kHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 50 kHz to 100 kHz","range":"-20 dBm to -10 dBm","cmc":"0,041 dB"},{"name":"f = 50 kHz to 100 kHz","range":"-10 dBm to 0 dBm","cmc":"0,028 dB"},{"name":"f = 50 kHz to 100 kHz","range":"0 dBm to 30 dBm","cmc":"0,052 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-130 dBm to -120 dBm","cmc":"1,2 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-120 dBm to -110 dBm","cmc":"0,57 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-110 dBm to -100 dBm","cmc":"0,23 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-100 dBm to -90 dBm","cmc":"0,11 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-90 dBm to -80 dBm","cmc":"0,10 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-80 dBm to -70 dBm","cmc":"0,097 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-60 dBm to -50 dBm","cmc":"0,067 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-50 dBm to -40 dBm","cmc":"0,065 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz to 10 MHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz to 10 MHz","range":"20 dBm to 30 dBm","cmc":"0,060 dB"},{"name":"f = 100 kHz to 10 MHz","range":"30 dBm to 45 dBm","cmc":"0,18 dB"},{"name":"f = 100 kHz to 10 MHz","range":"45 dBm to 52 dBm","cmc":"0,21 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-130 dBm to -120 dBm","cmc":"0,94 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-120 dBm to -110 dBm","cmc":"0,44 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-110 dBm to -100 dBm","cmc":"0,18 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-100 dBm to -90 dBm","cmc":"0,11 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-90 dBm to -80 dBm","cmc":"0,10 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-80 dBm to -70 dBm","cmc":"0,099 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-70 dBm to -60 dBm","cmc":"0,095 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-60 dBm to -50 dBm","cmc":"0,071 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-50 dBm to -40 dBm","cmc":"0,068 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-40 dBm to -30 dBm","cmc":"0,066 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-30 dBm to -20 dBm","cmc":"0,060 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-20 dBm to -10 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-10 dBm to 0 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"0 dBm to 20 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"20 dBm to 35 dBm","cmc":"0,060 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"35 dBm to 45 dBm","cmc":"0,18 dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"45 dBm to 52 dBm","cmc":"0,21 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-120 dBm to -110 dBm","cmc":"0,82 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-110 dBm to -100 dBm","cmc":"0,37 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-100 dBm to -90 dBm","cmc":"0,16 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-90 dBm to -80 dBm","cmc":"0,10 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-80 dBm to -70 dBm","cmc":"0,097 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-60 dBm to -50 dBm","cmc":"0,089 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-50 dBm to -40 dBm","cmc":"0,065 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"20 dBm to 35 dBm","cmc":"0,058 dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"35 dBm to 44 dBm","cmc":"0,18 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-110 dBm to -100 dBm","cmc":"0,76 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,33 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,14 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,097 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,089 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,065 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"20 dBm to 30 dBm","cmc":"0,060 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"30 dBm to 35 dBm","cmc":"0,083 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"35 dBm to 44 dBm","cmc":"0,19 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-90 dBm to -80 dBm","cmc":"0,27 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-80 dBm to -70 dBm","cmc":"0,13 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-60 dBm to -50 dBm","cmc":"0,089 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-50 dBm to -40 dBm","cmc":"0,085 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"20 dBm to 30 dBm","cmc":"0,060 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"30 dBm to 35 dBm","cmc":"0,13 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"35 dBm to 44 dBm","cmc":"0,22 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,28 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,14 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,098 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,079 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,077 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,075 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,073 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,073 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"20 dBm to 30 dBm","cmc":"0,077 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-100 dBm to -90 dBm","cmc":"1,1 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-90 dBm to -80 dBm","cmc":"0,52 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-80 dBm to -70 dBm","cmc":"0,22 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-60 dBm to -50 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-50 dBm to -40 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-40 dBm to -30 dBm","cmc":"0,11 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-30 dBm to -20 dBm","cmc":"0,098 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-20 dBm to -10 dBm","cmc":"0,097 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-10 dBm to 0 dBm","cmc":"0,095 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"0 dBm to 20 dBm","cmc":"0,095 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"20 dBm to 30 dBm","cmc":"0,098 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-80 dBm to -70 dBm","cmc":"0,37 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-70 dBm to -60 dBm","cmc":"0,18 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-60 dBm to -50 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-50 dBm to -40 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-40 dBm to -30 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-30 dBm to -20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-20 dBm to -10 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-10 dBm to 0 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"0 dBm to 20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"20 dBm to 30 dBm","cmc":"0,12 dB"},{"name":"f = 40 GHz to 50 GHz","range":"-40 dBm to -30 dBm","cmc":"0,19 dB"},{"name":"f = 40 GHz to 50 GHz","range":"-30 dBm to -20 dBm","cmc":"0,19 dB"},{"name":"f = 40 GHz to 50 GHz","range":"-20 dBm to -10 dBm","cmc":"0,15 dB"},{"name":"f = 40 GHz to 50 GHz","range":"-10 dBm to 0 dBm","cmc":"0,14 dB"},{"name":"f = 40 GHz to 50 GHz","range":"0 dBm to 20 dBm","cmc":"0,14 dB"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 10 Hz do 9 kHz -40 dBm do -30 dBm CMC 0,20 dB\nf = 10 Hz do 9 kHz -30 dBm do -20 dBm CMC 0,068 dB\nf = 10 Hz do 9 kHz -20 dBm do -10 dBm CMC 0,029 dB\nf = 10 Hz do 9 kHz -10 dBm do 0 dBm CMC 0,019 dB\nf = 10 Hz do 9 kHz 0 dBm do 30 dBm CMC 0,024 dB\nf = 9 kHz do 20 kHz -40 dBm do -30 dBm CMC 0,14 dB\nf = 9 kHz do 20 kHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 9 kHz do 20 kHz -20 dBm do -10 dBm CMC 0,029 dB\nf = 9 kHz do 20 kHz -10 dBm do 0 dBm CMC 0,019 dB\nf = 9 kHz do 20 kHz 0 dBm do 30 dBm CMC 0,024 dB\nf = 20 kHz do 50 kHz -40 dBm do -30 dBm CMC 0,14 dB\nf = 20 kHz do 50 kHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 20 kHz do 50 kHz -20 dBm do -10 dBm CMC 0,034 dB\nf = 20 kHz do 50 kHz -10 dBm do 0 dBm CMC 0,023 dB\nf = 20 kHz do 50 kHz 0 dBm do 30 dBm CMC 0,033 dB\nf = 50 kHz do 100 kHz -40 dBm do -30 dBm CMC 0,14 dB\nf = 50 kHz do 100 kHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 50 kHz do 100 kHz -20 dBm do -10 dBm CMC 0,041 dB\nf = 50 kHz do 100 kHz -10 dBm do 0 dBm CMC 0,028 dB\nf = 50 kHz do 100 kHz 0 dBm do 30 dBm CMC 0,052 dB\nf = 100 kHz do 10 MHz -130 dBm do -120 dBm CMC 1,2 dB\nf = 100 kHz do 10 MHz -120 dBm do -110 dBm CMC 0,57 dB\nf = 100 kHz do 10 MHz -110 dBm do -100 dBm CMC 0,23 dB\nf = 100 kHz do 10 MHz -100 dBm do -90 dBm CMC 0,11 dB\nf = 100 kHz do 10 MHz -90 dBm do -80 dBm CMC 0,10 dB\nf = 100 kHz do 10 MHz -80 dBm do -70 dBm CMC 0,097 dB\nf = 100 kHz do 10 MHz -70 dBm do -60 dBm CMC 0,093 dB\nf = 100 kHz do 10 MHz -60 dBm do -50 dBm CMC 0,067 dB\nf = 100 kHz do 10 MHz -50 dBm do -40 dBm CMC 0,065 dB\nf = 100 kHz do 10 MHz -40 dBm do -30 dBm CMC 0,062 dB\nf = 100 kHz do 10 MHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 100 kHz do 10 MHz -20 dBm do -10 dBm CMC 0,055 dB\nf = 100 kHz do 10 MHz -10 dBm do 0 dBm CMC 0,055 dB\nf = 100 kHz do 10 MHz 0 dBm do 20 dBm CMC 0,055 dB\nf = 100 kHz do 10 MHz 20 dBm do 30 dBm CMC 0,060 dB\nf = 100 kHz do 10 MHz 30 dBm do 45 dBm CMC 0,18 dB\nf = 100 kHz do 10 MHz 45 dBm do 52 dBm CMC 0,21 dB\nf = 10 MHz do 3,05 GHz -130 dBm do -120 dBm CMC 0,94 dB\nf = 10 MHz do 3,05 GHz -120 dBm do -110 dBm CMC 0,44 dB\nf = 10 MHz do 3,05 GHz -110 dBm do -100 dBm CMC 0,18 dB\nf = 10 MHz do 3,05 GHz -100 dBm do -90 dBm CMC 0,11 dB\nf = 10 MHz do 3,05 GHz -90 dBm do -80 dBm CMC 0,10 dB\nf = 10 MHz do 3,05 GHz -80 dBm do -70 dBm CMC 0,099 dB\nf = 10 MHz do 3,05 GHz -70 dBm do -60 dBm CMC 0,095 dB\nf = 10 MHz do 3,05 GHz -60 dBm do -50 dBm CMC 0,071 dB\nf = 10 MHz do 3,05 GHz -50 dBm do -40 dBm CMC 0,068 dB\nf = 10 MHz do 3,05 GHz -40 dBm do -30 dBm CMC 0,066 dB\nf = 10 MHz do 3,05 GHz -30 dBm do -20 dBm CMC 0,060 dB\nf = 10 MHz do 3,05 GHz -20 dBm do -10 dBm CMC 0,059 dB\nf = 10 MHz do 3,05 GHz -10 dBm do 0 dBm CMC 0,059 dB\nf = 10 MHz do 3,05 GHz 0 dBm do 20 dBm CMC 0,059 dB\nf = 10 MHz do 3,05 GHz 20 dBm do 35 dBm CMC 0,060 dB\nf = 10 MHz do 3,05 GHz 35 dBm do 45 dBm CMC 0,18 dB\nf = 10 MHz do 3,05 GHz 45 dBm do 52 dBm CMC 0,21 dB\nf = 3,05 GHz do 6,6 GHz -120 dBm do -110 dBm CMC 0,82 dB\nf = 3,05 GHz do 6,6 GHz -110 dBm do -100 dBm CMC 0,37 dB\nf = 3,05 GHz do 6,6 GHz -100 dBm do -90 dBm CMC 0,16 dB\nf = 3,05 GHz do 6,6 GHz -90 dBm do -80 dBm CMC 0,10 dB\nf = 3,05 GHz do 6,6 GHz -80 dBm do -70 dBm CMC 0,097 dB\nf = 3,05 GHz do 6,6 GHz -70 dBm do -60 dBm CMC 0,093 dB\nf = 3,05 GHz do 6,6 GHz -60 dBm do -50 dBm CMC 0,089 dB\nf = 3,05 GHz do 6,6 GHz -50 dBm do -40 dBm CMC 0,065 dB\nf = 3,05 GHz do 6,6 GHz -40 dBm do -30 dBm CMC 0,062 dB\nf = 3,05 GHz do 6,6 GHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 3,05 GHz do 6,6 GHz -20 dBm do -10 dBm CMC 0,055 dB\nf = 3,05 GHz do 6,6 GHz -10 dBm do 0 dBm CMC 0,055 dB\nf = 3,05 GHz do 6,6 GHz 0 dBm do 20 dBm CMC 0,055 dB\nf = 3,05 GHz do 6,6 GHz 20 dBm do 35 dBm CMC 0,058 dB\nf = 3,05 GHz do 6,6 GHz 35 dBm do 44 dBm CMC 0,18 dB\nf = 6,6 GHz do 13,2 GHz -110 dBm do -100 dBm CMC 0,76 dB\nf = 6,6 GHz do 13,2 GHz -100 dBm do -90 dBm CMC 0,33 dB\nf = 6,6 GHz do 13,2 GHz -90 dBm do -80 dBm CMC 0,14 dB\nf = 6,6 GHz do 13,2 GHz -80 dBm do -70 dBm CMC 0,097 dB\nf = 6,6 GHz do 13,2 GHz -70 dBm do -60 dBm CMC 0,093 dB\nf = 6,6 GHz do 13,2 GHz -60 dBm do -50 dBm CMC 0,089 dB\nf = 6,6 GHz do 13,2 GHz -50 dBm do -40 dBm CMC 0,065 dB\nf = 6,6 GHz do 13,2 GHz -40 dBm do -30 dBm CMC 0,062 dB\nf = 6,6 GHz do 13,2 GHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 6,6 GHz do 13,2 GHz -20 dBm do -10 dBm CMC 0,055 dB\nf = 6,6 GHz do 13,2 GHz -10 dBm do 0 dBm CMC 0,055 dB\nf = 6,6 GHz do 13,2 GHz 0 dBm do 20 dBm CMC 0,055 dB\nf = 6,6 GHz do 13,2 GHz 20 dBm do 30 dBm CMC 0,060 dB\nf = 6,6 GHz do 13,2 GHz 30 dBm do 35 dBm CMC 0,083 dB\nf = 6,6 GHz do 13,2 GHz 35 dBm do 44 dBm CMC 0,19 dB\nf = 13,2 GHz do 18 GHz -100 dBm do -90 dBm CMC 0,65 dB\nf = 13,2 GHz do 18 GHz -90 dBm do -80 dBm CMC 0,27 dB\nf = 13,2 GHz do 18 GHz -80 dBm do -70 dBm CMC 0,13 dB\nf = 13,2 GHz do 18 GHz -70 dBm do -60 dBm CMC 0,093 dB\nf = 13,2 GHz do 18 GHz -60 dBm do -50 dBm CMC 0,089 dB\nf = 13,2 GHz do 18 GHz -50 dBm do -40 dBm CMC 0,085 dB\nf = 13,2 GHz do 18 GHz -40 dBm do -30 dBm CMC 0,062 dB\nf = 13,2 GHz do 18 GHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 13,2 GHz do 18 GHz -20 dBm do -10 dBm CMC 0,055 dB\nf = 13,2 GHz do 18 GHz -10 dBm do 0 dBm CMC 0,055 dB\nf = 13,2 GHz do 18 GHz 0 dBm do 20 dBm CMC 0,055 dB\nf = 13,2 GHz do 18 GHz 20 dBm do 30 dBm CMC 0,060 dB\nf = 13,2 GHz do 18 GHz 30 dBm do 35 dBm CMC 0,13 dB\nf = 13,2 GHz do 18 GHz 35 dBm do 44 dBm CMC 0,22 dB\nf = 18 GHz do 19,2 GHz -100 dBm do -90 dBm CMC 0,65 dB\nf = 18 GHz do 19,2 GHz -90 dBm do -80 dBm CMC 0,28 dB\nf = 18 GHz do 19,2 GHz -80 dBm do -70 dBm CMC 0,14 dB\nf = 18 GHz do 19,2 GHz -70 dBm do -60 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz -60 dBm do -50 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz -50 dBm do -40 dBm CMC 0,098 dB\nf = 18 GHz do 19,2 GHz -40 dBm do -30 dBm CMC 0,079 dB\nf = 18 GHz do 19,2 GHz -30 dBm do -20 dBm CMC 0,077 dB\nf = 18 GHz do 19,2 GHz -20 dBm do -10 dBm CMC 0,075 dB\nf = 18 GHz do 19,2 GHz -10 dBm do 0 dBm CMC 0,073 dB\nf = 18 GHz do 19,2 GHz 0 dBm do 20 dBm CMC 0,073 dB\nf = 18 GHz do 19,2 GHz 20 dBm do 30 dBm CMC 0,077 dB\nf = 19,2 GHz do 26,5 GHz -100 dBm do -90 dBm CMC 1,1 dB\nf = 19,2 GHz do 26,5 GHz -90 dBm do -80 dBm CMC 0,52 dB\nf = 19,2 GHz do 26,5 GHz -80 dBm do -70 dBm CMC 0,22 dB\nf = 19,2 GHz do 26,5 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -60 dBm do -50 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -50 dBm do -40 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -40 dBm do -30 dBm CMC 0,11 dB\nf = 19,2 GHz do 26,5 GHz -30 dBm do -20 dBm CMC 0,098 dB\nf = 19,2 GHz do 26,5 GHz -20 dBm do -10 dBm CMC 0,097 dB\nf = 19,2 GHz do 26,5 GHz -10 dBm do 0 dBm CMC 0,095 dB\nf = 19,2 GHz do 26,5 GHz 0 dBm do 20 dBm CMC 0,095 dB\nf = 19,2 GHz do 26,5 GHz 20 dBm do 30 dBm CMC 0,098 dB\nf = 26,5 GHz do 40 GHz -80 dBm do -70 dBm CMC 0,37 dB\nf = 26,5 GHz do 40 GHz -70 dBm do -60 dBm CMC 0,18 dB\nf = 26,5 GHz do 40 GHz -60 dBm do -50 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -50 dBm do -40 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -40 dBm do -30 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz -30 dBm do -20 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz -20 dBm do -10 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz -10 dBm do 0 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz 0 dBm do 20 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz 20 dBm do 30 dBm CMC 0,12 dB\nf = 40 GHz do 50 GHz -40 dBm do -30 dBm CMC 0,19 dB\nf = 40 GHz do 50 GHz -30 dBm do -20 dBm CMC 0,19 dB\nf = 40 GHz do 50 GHz -20 dBm do -10 dBm CMC 0,15 dB\nf = 40 GHz do 50 GHz -10 dBm do 0 dBm CMC 0,14 dB\nf = 40 GHz do 50 GHz 0 dBm do 20 dBm CMC 0,14 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/32\nLMEEiO/39\nLMEEiO/40\nLMEEiO/48","norm_bases":["LMEEiO/32","LMEEiO/39","LMEEiO/40","LMEEiO/48"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Generatory\nAnalizatory obwodów\nAnalizatory widma\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\nWzmacniacze\n- poziom mocy wyjściowej Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 10 Hz do 9 kHz -40 dBm do -30 dBm CMC 0,20 dB\nf = 10 Hz do 9 kHz -30 dBm do -20 dBm CMC 0,068 dB\nf = 10 Hz do 9 kHz -20 dBm do -10 dBm CMC 0,029 dB\nf = 10 Hz do 9 kHz -10 dBm do 0 dBm CMC 0,019 dB\nf = 10 Hz do 9 kHz 0 dBm do 30 dBm CMC 0,024 dB\nf = 9 kHz do 20 kHz -40 dBm do -30 dBm CMC 0,14 dB\nf = 9 kHz do 20 kHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 9 kHz do 20 kHz -20 dBm do -10 dBm CMC 0,029 dB\nf = 9 kHz do 20 kHz -10 dBm do 0 dBm CMC 0,019 dB\nf = 9 kHz do 20 kHz 0 dBm do 30 dBm CMC 0,024 dB\nf = 20 kHz do 50 kHz -40 dBm do -30 dBm CMC 0,14 dB\nf = 20 kHz do 50 kHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 20 kHz do 50 kHz -20 dBm do -10 dBm CMC 0,034 dB\nf = 20 kHz do 50 kHz -10 dBm do 0 dBm CMC 0,023 dB\nf = 20 kHz do 50 kHz 0 dBm do 30 dBm CMC 0,033 dB\nf = 50 kHz do 100 kHz -40 dBm do -30 dBm CMC 0,14 dB\nf = 50 kHz do 100 kHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 50 kHz do 100 kHz -20 dBm do -10 dBm CMC 0,041 dB\nf = 50 kHz do 100 kHz -10 dBm do 0 dBm CMC 0,028 dB\nf = 50 kHz do 100 kHz 0 dBm do 30 dBm CMC 0,052 dB\nf = 100 kHz do 10 MHz -130 dBm do -120 dBm CMC 1,2 dB\nf = 100 kHz do 10 MHz -120 dBm do -110 dBm CMC 0,57 dB\nf = 100 kHz do 10 MHz -110 dBm do -100 dBm CMC 0,23 dB\nf = 100 kHz do 10 MHz -100 dBm do -90 dBm CMC 0,11 dB\nf = 100 kHz do 10 MHz -90 dBm do -80 dBm CMC 0,10 dB\nf = 100 kHz do 10 MHz -80 dBm do -70 dBm CMC 0,097 dB\nf = 100 kHz do 10 MHz -70 dBm do -60 dBm CMC 0,093 dB\nf = 100 kHz do 10 MHz -60 dBm do -50 dBm CMC 0,067 dB\nf = 100 kHz do 10 MHz -50 dBm do -40 dBm CMC 0,065 dB\nf = 100 kHz do 10 MHz -40 dBm do -30 dBm CMC 0,062 dB\nf = 100 kHz do 10 MHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 100 kHz do 10 MHz -20 dBm do -10 dBm CMC 0,055 dB\nf = 100 kHz do 10 MHz -10 dBm do 0 dBm CMC 0,055 dB\nf = 100 kHz do 10 MHz 0 dBm do 20 dBm CMC 0,055 dB\nf = 100 kHz do 10 MHz 20 dBm do 30 dBm CMC 0,060 dB\nf = 100 kHz do 10 MHz 30 dBm do 45 dBm CMC 0,18 dB\nf = 100 kHz do 10 MHz 45 dBm do 52 dBm CMC 0,21 dB\nf = 10 MHz do 3,05 GHz -130 dBm do -120 dBm CMC 0,94 dB\nf = 10 MHz do 3,05 GHz -120 dBm do -110 dBm CMC 0,44 dB\nf = 10 MHz do 3,05 GHz -110 dBm do -100 dBm CMC 0,18 dB\nf = 10 MHz do 3,05 GHz -100 dBm do -90 dBm CMC 0,11 dB\nf = 10 MHz do 3,05 GHz -90 dBm do -80 dBm CMC 0,10 dB\nf = 10 MHz do 3,05 GHz -80 dBm do -70 dBm CMC 0,099 dB\nf = 10 MHz do 3,05 GHz -70 dBm do -60 dBm CMC 0,095 dB\nf = 10 MHz do 3,05 GHz -60 dBm do -50 dBm CMC 0,071 dB\nf = 10 MHz do 3,05 GHz -50 dBm do -40 dBm CMC 0,068 dB\nf = 10 MHz do 3,05 GHz -40 dBm do -30 dBm CMC 0,066 dB\nf = 10 MHz do 3,05 GHz -30 dBm do -20 dBm CMC 0,060 dB\nf = 10 MHz do 3,05 GHz -20 dBm do -10 dBm CMC 0,059 dB\nf = 10 MHz do 3,05 GHz -10 dBm do 0 dBm CMC 0,059 dB\nf = 10 MHz do 3,05 GHz 0 dBm do 20 dBm CMC 0,059 dB\nf = 10 MHz do 3,05 GHz 20 dBm do 35 dBm CMC 0,060 dB\nf = 10 MHz do 3,05 GHz 35 dBm do 45 dBm CMC 0,18 dB\nf = 10 MHz do 3,05 GHz 45 dBm do 52 dBm CMC 0,21 dB\nf = 3,05 GHz do 6,6 GHz -120 dBm do -110 dBm CMC 0,82 dB\nf = 3,05 GHz do 6,6 GHz -110 dBm do -100 dBm CMC 0,37 dB\nf = 3,05 GHz do 6,6 GHz -100 dBm do -90 dBm CMC 0,16 dB\nf = 3,05 GHz do 6,6 GHz -90 dBm do -80 dBm CMC 0,10 dB\nf = 3,05 GHz do 6,6 GHz -80 dBm do -70 dBm CMC 0,097 dB\nf = 3,05 GHz do 6,6 GHz -70 dBm do -60 dBm CMC 0,093 dB\nf = 3,05 GHz do 6,6 GHz -60 dBm do -50 dBm CMC 0,089 dB\nf = 3,05 GHz do 6,6 GHz -50 dBm do -40 dBm CMC 0,065 dB\nf = 3,05 GHz do 6,6 GHz -40 dBm do -30 dBm CMC 0,062 dB\nf = 3,05 GHz do 6,6 GHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 3,05 GHz do 6,6 GHz -20 dBm do -10 dBm CMC 0,055 dB\nf = 3,05 GHz do 6,6 GHz -10 dBm do 0 dBm CMC 0,055 dB\nf = 3,05 GHz do 6,6 GHz 0 dBm do 20 dBm CMC 0,055 dB\nf = 3,05 GHz do 6,6 GHz 20 dBm do 35 dBm CMC 0,058 dB\nf = 3,05 GHz do 6,6 GHz 35 dBm do 44 dBm CMC 0,18 dB\nf = 6,6 GHz do 13,2 GHz -110 dBm do -100 dBm CMC 0,76 dB\nf = 6,6 GHz do 13,2 GHz -100 dBm do -90 dBm CMC 0,33 dB\nf = 6,6 GHz do 13,2 GHz -90 dBm do -80 dBm CMC 0,14 dB\nf = 6,6 GHz do 13,2 GHz -80 dBm do -70 dBm CMC 0,097 dB\nf = 6,6 GHz do 13,2 GHz -70 dBm do -60 dBm CMC 0,093 dB\nf = 6,6 GHz do 13,2 GHz -60 dBm do -50 dBm CMC 0,089 dB\nf = 6,6 GHz do 13,2 GHz -50 dBm do -40 dBm CMC 0,065 dB\nf = 6,6 GHz do 13,2 GHz -40 dBm do -30 dBm CMC 0,062 dB\nf = 6,6 GHz do 13,2 GHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 6,6 GHz do 13,2 GHz -20 dBm do -10 dBm CMC 0,055 dB\nf = 6,6 GHz do 13,2 GHz -10 dBm do 0 dBm CMC 0,055 dB\nf = 6,6 GHz do 13,2 GHz 0 dBm do 20 dBm CMC 0,055 dB\nf = 6,6 GHz do 13,2 GHz 20 dBm do 30 dBm CMC 0,060 dB\nf = 6,6 GHz do 13,2 GHz 30 dBm do 35 dBm CMC 0,083 dB\nf = 6,6 GHz do 13,2 GHz 35 dBm do 44 dBm CMC 0,19 dB\nf = 13,2 GHz do 18 GHz -100 dBm do -90 dBm CMC 0,65 dB\nf = 13,2 GHz do 18 GHz -90 dBm do -80 dBm CMC 0,27 dB\nf = 13,2 GHz do 18 GHz -80 dBm do -70 dBm CMC 0,13 dB\nf = 13,2 GHz do 18 GHz -70 dBm do -60 dBm CMC 0,093 dB\nf = 13,2 GHz do 18 GHz -60 dBm do -50 dBm CMC 0,089 dB\nf = 13,2 GHz do 18 GHz -50 dBm do -40 dBm CMC 0,085 dB\nf = 13,2 GHz do 18 GHz -40 dBm do -30 dBm CMC 0,062 dB\nf = 13,2 GHz do 18 GHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 13,2 GHz do 18 GHz -20 dBm do -10 dBm CMC 0,055 dB\nf = 13,2 GHz do 18 GHz -10 dBm do 0 dBm CMC 0,055 dB\nf = 13,2 GHz do 18 GHz 0 dBm do 20 dBm CMC 0,055 dB\nf = 13,2 GHz do 18 GHz 20 dBm do 30 dBm CMC 0,060 dB\nf = 13,2 GHz do 18 GHz 30 dBm do 35 dBm CMC 0,13 dB\nf = 13,2 GHz do 18 GHz 35 dBm do 44 dBm CMC 0,22 dB\nf = 18 GHz do 19,2 GHz -100 dBm do -90 dBm CMC 0,65 dB\nf = 18 GHz do 19,2 GHz -90 dBm do -80 dBm CMC 0,28 dB\nf = 18 GHz do 19,2 GHz -80 dBm do -70 dBm CMC 0,14 dB\nf = 18 GHz do 19,2 GHz -70 dBm do -60 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz -60 dBm do -50 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz -50 dBm do -40 dBm CMC 0,098 dB\nf = 18 GHz do 19,2 GHz -40 dBm do -30 dBm CMC 0,079 dB\nf = 18 GHz do 19,2 GHz -30 dBm do -20 dBm CMC 0,077 dB\nf = 18 GHz do 19,2 GHz -20 dBm do -10 dBm CMC 0,075 dB\nf = 18 GHz do 19,2 GHz -10 dBm do 0 dBm CMC 0,073 dB\nf = 18 GHz do 19,2 GHz 0 dBm do 20 dBm CMC 0,073 dB\nf = 18 GHz do 19,2 GHz 20 dBm do 30 dBm CMC 0,077 dB\nf = 19,2 GHz do 26,5 GHz -100 dBm do -90 dBm CMC 1,1 dB\nf = 19,2 GHz do 26,5 GHz -90 dBm do -80 dBm CMC 0,52 dB\nf = 19,2 GHz do 26,5 GHz -80 dBm do -70 dBm CMC 0,22 dB\nf = 19,2 GHz do 26,5 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -60 dBm do -50 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -50 dBm do -40 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -40 dBm do -30 dBm CMC 0,11 dB\nf = 19,2 GHz do 26,5 GHz -30 dBm do -20 dBm CMC 0,098 dB\nf = 19,2 GHz do 26,5 GHz -20 dBm do -10 dBm CMC 0,097 dB\nf = 19,2 GHz do 26,5 GHz -10 dBm do 0 dBm CMC 0,095 dB\nf = 19,2 GHz do 26,5 GHz 0 dBm do 20 dBm CMC 0,095 dB\nf = 19,2 GHz do 26,5 GHz 20 dBm do 30 dBm CMC 0,098 dB\nf = 26,5 GHz do 40 GHz -80 dBm do -70 dBm CMC 0,37 dB\nf = 26,5 GHz do 40 GHz -70 dBm do -60 dBm CMC 0,18 dB\nf = 26,5 GHz do 40 GHz -60 dBm do -50 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -50 dBm do -40 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -40 dBm do -30 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz -30 dBm do -20 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz -20 dBm do -10 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz -10 dBm do 0 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz 0 dBm do 20 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz 20 dBm do 30 dBm CMC 0,12 dB\nf = 40 GHz do 50 GHz -40 dBm do -30 dBm CMC 0,19 dB\nf = 40 GHz do 50 GHz -30 dBm do -20 dBm CMC 0,19 dB\nf = 40 GHz do 50 GHz -20 dBm do -10 dBm CMC 0,15 dB\nf = 40 GHz do 50 GHz -10 dBm do 0 dBm CMC 0,14 dB\nf = 40 GHz do 50 GHz 0 dBm do 20 dBm CMC 0,14 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/32\nLMEEiO/39\nLMEEiO/40\nLMEEiO/48 Generatory\nAnalizatory obwodow\nAnalizatory widma\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\nWzmacniacze\n- poziom mocy wyjsciowej Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\nf = 10 Hz do 9 kHz -40 dBm do -30 dBm CMC 0,20 dB\nf = 10 Hz do 9 kHz -30 dBm do -20 dBm CMC 0,068 dB\nf = 10 Hz do 9 kHz -20 dBm do -10 dBm CMC 0,029 dB\nf = 10 Hz do 9 kHz -10 dBm do 0 dBm CMC 0,019 dB\nf = 10 Hz do 9 kHz 0 dBm do 30 dBm CMC 0,024 dB\nf = 9 kHz do 20 kHz -40 dBm do -30 dBm CMC 0,14 dB\nf = 9 kHz do 20 kHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 9 kHz do 20 kHz -20 dBm do -10 dBm CMC 0,029 dB\nf = 9 kHz do 20 kHz -10 dBm do 0 dBm CMC 0,019 dB\nf = 9 kHz do 20 kHz 0 dBm do 30 dBm CMC 0,024 dB\nf = 20 kHz do 50 kHz -40 dBm do -30 dBm CMC 0,14 dB\nf = 20 kHz do 50 kHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 20 kHz do 50 kHz -20 dBm do -10 dBm CMC 0,034 dB\nf = 20 kHz do 50 kHz -10 dBm do 0 dBm CMC 0,023 dB\nf = 20 kHz do 50 kHz 0 dBm do 30 dBm CMC 0,033 dB\nf = 50 kHz do 100 kHz -40 dBm do -30 dBm CMC 0,14 dB\nf = 50 kHz do 100 kHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 50 kHz do 100 kHz -20 dBm do -10 dBm CMC 0,041 dB\nf = 50 kHz do 100 kHz -10 dBm do 0 dBm CMC 0,028 dB\nf = 50 kHz do 100 kHz 0 dBm do 30 dBm CMC 0,052 dB\nf = 100 kHz do 10 MHz -130 dBm do -120 dBm CMC 1,2 dB\nf = 100 kHz do 10 MHz -120 dBm do -110 dBm CMC 0,57 dB\nf = 100 kHz do 10 MHz -110 dBm do -100 dBm CMC 0,23 dB\nf = 100 kHz do 10 MHz -100 dBm do -90 dBm CMC 0,11 dB\nf = 100 kHz do 10 MHz -90 dBm do -80 dBm CMC 0,10 dB\nf = 100 kHz do 10 MHz -80 dBm do -70 dBm CMC 0,097 dB\nf = 100 kHz do 10 MHz -70 dBm do -60 dBm CMC 0,093 dB\nf = 100 kHz do 10 MHz -60 dBm do -50 dBm CMC 0,067 dB\nf = 100 kHz do 10 MHz -50 dBm do -40 dBm CMC 0,065 dB\nf = 100 kHz do 10 MHz -40 dBm do -30 dBm CMC 0,062 dB\nf = 100 kHz do 10 MHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 100 kHz do 10 MHz -20 dBm do -10 dBm CMC 0,055 dB\nf = 100 kHz do 10 MHz -10 dBm do 0 dBm CMC 0,055 dB\nf = 100 kHz do 10 MHz 0 dBm do 20 dBm CMC 0,055 dB\nf = 100 kHz do 10 MHz 20 dBm do 30 dBm CMC 0,060 dB\nf = 100 kHz do 10 MHz 30 dBm do 45 dBm CMC 0,18 dB\nf = 100 kHz do 10 MHz 45 dBm do 52 dBm CMC 0,21 dB\nf = 10 MHz do 3,05 GHz -130 dBm do -120 dBm CMC 0,94 dB\nf = 10 MHz do 3,05 GHz -120 dBm do -110 dBm CMC 0,44 dB\nf = 10 MHz do 3,05 GHz -110 dBm do -100 dBm CMC 0,18 dB\nf = 10 MHz do 3,05 GHz -100 dBm do -90 dBm CMC 0,11 dB\nf = 10 MHz do 3,05 GHz -90 dBm do -80 dBm CMC 0,10 dB\nf = 10 MHz do 3,05 GHz -80 dBm do -70 dBm CMC 0,099 dB\nf = 10 MHz do 3,05 GHz -70 dBm do -60 dBm CMC 0,095 dB\nf = 10 MHz do 3,05 GHz -60 dBm do -50 dBm CMC 0,071 dB\nf = 10 MHz do 3,05 GHz -50 dBm do -40 dBm CMC 0,068 dB\nf = 10 MHz do 3,05 GHz -40 dBm do -30 dBm CMC 0,066 dB\nf = 10 MHz do 3,05 GHz -30 dBm do -20 dBm CMC 0,060 dB\nf = 10 MHz do 3,05 GHz -20 dBm do -10 dBm CMC 0,059 dB\nf = 10 MHz do 3,05 GHz -10 dBm do 0 dBm CMC 0,059 dB\nf = 10 MHz do 3,05 GHz 0 dBm do 20 dBm CMC 0,059 dB\nf = 10 MHz do 3,05 GHz 20 dBm do 35 dBm CMC 0,060 dB\nf = 10 MHz do 3,05 GHz 35 dBm do 45 dBm CMC 0,18 dB\nf = 10 MHz do 3,05 GHz 45 dBm do 52 dBm CMC 0,21 dB\nf = 3,05 GHz do 6,6 GHz -120 dBm do -110 dBm CMC 0,82 dB\nf = 3,05 GHz do 6,6 GHz -110 dBm do -100 dBm CMC 0,37 dB\nf = 3,05 GHz do 6,6 GHz -100 dBm do -90 dBm CMC 0,16 dB\nf = 3,05 GHz do 6,6 GHz -90 dBm do -80 dBm CMC 0,10 dB\nf = 3,05 GHz do 6,6 GHz -80 dBm do -70 dBm CMC 0,097 dB\nf = 3,05 GHz do 6,6 GHz -70 dBm do -60 dBm CMC 0,093 dB\nf = 3,05 GHz do 6,6 GHz -60 dBm do -50 dBm CMC 0,089 dB\nf = 3,05 GHz do 6,6 GHz -50 dBm do -40 dBm CMC 0,065 dB\nf = 3,05 GHz do 6,6 GHz -40 dBm do -30 dBm CMC 0,062 dB\nf = 3,05 GHz do 6,6 GHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 3,05 GHz do 6,6 GHz -20 dBm do -10 dBm CMC 0,055 dB\nf = 3,05 GHz do 6,6 GHz -10 dBm do 0 dBm CMC 0,055 dB\nf = 3,05 GHz do 6,6 GHz 0 dBm do 20 dBm CMC 0,055 dB\nf = 3,05 GHz do 6,6 GHz 20 dBm do 35 dBm CMC 0,058 dB\nf = 3,05 GHz do 6,6 GHz 35 dBm do 44 dBm CMC 0,18 dB\nf = 6,6 GHz do 13,2 GHz -110 dBm do -100 dBm CMC 0,76 dB\nf = 6,6 GHz do 13,2 GHz -100 dBm do -90 dBm CMC 0,33 dB\nf = 6,6 GHz do 13,2 GHz -90 dBm do -80 dBm CMC 0,14 dB\nf = 6,6 GHz do 13,2 GHz -80 dBm do -70 dBm CMC 0,097 dB\nf = 6,6 GHz do 13,2 GHz -70 dBm do -60 dBm CMC 0,093 dB\nf = 6,6 GHz do 13,2 GHz -60 dBm do -50 dBm CMC 0,089 dB\nf = 6,6 GHz do 13,2 GHz -50 dBm do -40 dBm CMC 0,065 dB\nf = 6,6 GHz do 13,2 GHz -40 dBm do -30 dBm CMC 0,062 dB\nf = 6,6 GHz do 13,2 GHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 6,6 GHz do 13,2 GHz -20 dBm do -10 dBm CMC 0,055 dB\nf = 6,6 GHz do 13,2 GHz -10 dBm do 0 dBm CMC 0,055 dB\nf = 6,6 GHz do 13,2 GHz 0 dBm do 20 dBm CMC 0,055 dB\nf = 6,6 GHz do 13,2 GHz 20 dBm do 30 dBm CMC 0,060 dB\nf = 6,6 GHz do 13,2 GHz 30 dBm do 35 dBm CMC 0,083 dB\nf = 6,6 GHz do 13,2 GHz 35 dBm do 44 dBm CMC 0,19 dB\nf = 13,2 GHz do 18 GHz -100 dBm do -90 dBm CMC 0,65 dB\nf = 13,2 GHz do 18 GHz -90 dBm do -80 dBm CMC 0,27 dB\nf = 13,2 GHz do 18 GHz -80 dBm do -70 dBm CMC 0,13 dB\nf = 13,2 GHz do 18 GHz -70 dBm do -60 dBm CMC 0,093 dB\nf = 13,2 GHz do 18 GHz -60 dBm do -50 dBm CMC 0,089 dB\nf = 13,2 GHz do 18 GHz -50 dBm do -40 dBm CMC 0,085 dB\nf = 13,2 GHz do 18 GHz -40 dBm do -30 dBm CMC 0,062 dB\nf = 13,2 GHz do 18 GHz -30 dBm do -20 dBm CMC 0,057 dB\nf = 13,2 GHz do 18 GHz -20 dBm do -10 dBm CMC 0,055 dB\nf = 13,2 GHz do 18 GHz -10 dBm do 0 dBm CMC 0,055 dB\nf = 13,2 GHz do 18 GHz 0 dBm do 20 dBm CMC 0,055 dB\nf = 13,2 GHz do 18 GHz 20 dBm do 30 dBm CMC 0,060 dB\nf = 13,2 GHz do 18 GHz 30 dBm do 35 dBm CMC 0,13 dB\nf = 13,2 GHz do 18 GHz 35 dBm do 44 dBm CMC 0,22 dB\nf = 18 GHz do 19,2 GHz -100 dBm do -90 dBm CMC 0,65 dB\nf = 18 GHz do 19,2 GHz -90 dBm do -80 dBm CMC 0,28 dB\nf = 18 GHz do 19,2 GHz -80 dBm do -70 dBm CMC 0,14 dB\nf = 18 GHz do 19,2 GHz -70 dBm do -60 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz -60 dBm do -50 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz -50 dBm do -40 dBm CMC 0,098 dB\nf = 18 GHz do 19,2 GHz -40 dBm do -30 dBm CMC 0,079 dB\nf = 18 GHz do 19,2 GHz -30 dBm do -20 dBm CMC 0,077 dB\nf = 18 GHz do 19,2 GHz -20 dBm do -10 dBm CMC 0,075 dB\nf = 18 GHz do 19,2 GHz -10 dBm do 0 dBm CMC 0,073 dB\nf = 18 GHz do 19,2 GHz 0 dBm do 20 dBm CMC 0,073 dB\nf = 18 GHz do 19,2 GHz 20 dBm do 30 dBm CMC 0,077 dB\nf = 19,2 GHz do 26,5 GHz -100 dBm do -90 dBm CMC 1,1 dB\nf = 19,2 GHz do 26,5 GHz -90 dBm do -80 dBm CMC 0,52 dB\nf = 19,2 GHz do 26,5 GHz -80 dBm do -70 dBm CMC 0,22 dB\nf = 19,2 GHz do 26,5 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -60 dBm do -50 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -50 dBm do -40 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -40 dBm do -30 dBm CMC 0,11 dB\nf = 19,2 GHz do 26,5 GHz -30 dBm do -20 dBm CMC 0,098 dB\nf = 19,2 GHz do 26,5 GHz -20 dBm do -10 dBm CMC 0,097 dB\nf = 19,2 GHz do 26,5 GHz -10 dBm do 0 dBm CMC 0,095 dB\nf = 19,2 GHz do 26,5 GHz 0 dBm do 20 dBm CMC 0,095 dB\nf = 19,2 GHz do 26,5 GHz 20 dBm do 30 dBm CMC 0,098 dB\nf = 26,5 GHz do 40 GHz -80 dBm do -70 dBm CMC 0,37 dB\nf = 26,5 GHz do 40 GHz -70 dBm do -60 dBm CMC 0,18 dB\nf = 26,5 GHz do 40 GHz -60 dBm do -50 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -50 dBm do -40 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -40 dBm do -30 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz -30 dBm do -20 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz -20 dBm do -10 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz -10 dBm do 0 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz 0 dBm do 20 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz 20 dBm do 30 dBm CMC 0,12 dB\nf = 40 GHz do 50 GHz -40 dBm do -30 dBm CMC 0,19 dB\nf = 40 GHz do 50 GHz -30 dBm do -20 dBm CMC 0,19 dB\nf = 40 GHz do 50 GHz -20 dBm do -10 dBm CMC 0,15 dB\nf = 40 GHz do 50 GHz -10 dBm do 0 dBm CMC 0,14 dB\nf = 40 GHz do 50 GHz 0 dBm do 20 dBm CMC 0,14 dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/32\nLMEEiO/39\nLMEEiO/40\nLMEEiO/48","search_en":"Generators Network analysers Spectrum analysers Radio communication testers Measuring receivers Amplifiers - output power level Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) f = 10 Hz to 9 kHz f = 10 Hz to 9 kHz f = 10 Hz to 9 kHz f = 10 Hz to 9 kHz f = 10 Hz to 9 kHz f = 9 kHz to 20 kHz f = 9 kHz to 20 kHz f = 9 kHz to 20 kHz f = 9 kHz to 20 kHz f = 9 kHz to 20 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 40 GHz to 50 GHz f = 40 GHz to 50 GHz f = 40 GHz to 50 GHz f = 40 GHz to 50 GHz f = 40 GHz to 50 GHz LMEEiO/32 LMEEiO/39 LMEEiO/40 LMEEiO/48","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":41,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"f = 10 Hz bis 9 kHz","range":"-40 dBm to -30 dBm","cmc":"0,20 dB"},{"name":"f = 10 Hz bis 9 kHz","range":"-30 dBm to -20 dBm","cmc":"0,068 dB"},{"name":"f = 10 Hz bis 9 kHz","range":"-20 dBm to -10 dBm","cmc":"0,029 dB"},{"name":"f = 10 Hz bis 9 kHz","range":"-10 dBm to 0 dBm","cmc":"0,019 dB"},{"name":"f = 10 Hz bis 9 kHz","range":"0 dBm to 30 dBm","cmc":"0,024 dB"},{"name":"f = 9 kHz bis 20 kHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 9 kHz bis 20 kHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 9 kHz bis 20 kHz","range":"-20 dBm to -10 dBm","cmc":"0,029 dB"},{"name":"f = 9 kHz bis 20 kHz","range":"-10 dBm to 0 dBm","cmc":"0,019 dB"},{"name":"f = 9 kHz bis 20 kHz","range":"0 dBm to 30 dBm","cmc":"0,024 dB"},{"name":"f = 20 kHz bis 50 kHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 20 kHz bis 50 kHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 20 kHz bis 50 kHz","range":"-20 dBm to -10 dBm","cmc":"0,034 dB"},{"name":"f = 20 kHz bis 50 kHz","range":"-10 dBm to 0 dBm","cmc":"0,023 dB"},{"name":"f = 20 kHz bis 50 kHz","range":"0 dBm to 30 dBm","cmc":"0,033 dB"},{"name":"f = 50 kHz bis 100 kHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 50 kHz bis 100 kHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 50 kHz bis 100 kHz","range":"-20 dBm to -10 dBm","cmc":"0,041 dB"},{"name":"f = 50 kHz bis 100 kHz","range":"-10 dBm to 0 dBm","cmc":"0,028 dB"},{"name":"f = 50 kHz bis 100 kHz","range":"0 dBm to 30 dBm","cmc":"0,052 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-130 dBm to -120 dBm","cmc":"1,2 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-120 dBm to -110 dBm","cmc":"0,57 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-110 dBm to -100 dBm","cmc":"0,23 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-100 dBm to -90 dBm","cmc":"0,11 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-90 dBm to -80 dBm","cmc":"0,10 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-80 dBm to -70 dBm","cmc":"0,097 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-60 dBm to -50 dBm","cmc":"0,067 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-50 dBm to -40 dBm","cmc":"0,065 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"20 dBm to 30 dBm","cmc":"0,060 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"30 dBm to 45 dBm","cmc":"0,18 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"45 dBm to 52 dBm","cmc":"0,21 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-130 dBm to -120 dBm","cmc":"0,94 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-120 dBm to -110 dBm","cmc":"0,44 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-110 dBm to -100 dBm","cmc":"0,18 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-100 dBm to -90 dBm","cmc":"0,11 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-90 dBm to -80 dBm","cmc":"0,10 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-80 dBm to -70 dBm","cmc":"0,099 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-70 dBm to -60 dBm","cmc":"0,095 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-60 dBm to -50 dBm","cmc":"0,071 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-50 dBm to -40 dBm","cmc":"0,068 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-40 dBm to -30 dBm","cmc":"0,066 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-30 dBm to -20 dBm","cmc":"0,060 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-20 dBm to -10 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-10 dBm to 0 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"0 dBm to 20 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"20 dBm to 35 dBm","cmc":"0,060 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"35 dBm to 45 dBm","cmc":"0,18 dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"45 dBm to 52 dBm","cmc":"0,21 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-120 dBm to -110 dBm","cmc":"0,82 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-110 dBm to -100 dBm","cmc":"0,37 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-100 dBm to -90 dBm","cmc":"0,16 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-90 dBm to -80 dBm","cmc":"0,10 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-80 dBm to -70 dBm","cmc":"0,097 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-60 dBm to -50 dBm","cmc":"0,089 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-50 dBm to -40 dBm","cmc":"0,065 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"20 dBm to 35 dBm","cmc":"0,058 dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"35 dBm to 44 dBm","cmc":"0,18 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-110 dBm to -100 dBm","cmc":"0,76 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,33 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,14 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,097 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,089 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,065 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"20 dBm to 30 dBm","cmc":"0,060 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"30 dBm to 35 dBm","cmc":"0,083 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"35 dBm to 44 dBm","cmc":"0,19 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-90 dBm to -80 dBm","cmc":"0,27 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-80 dBm to -70 dBm","cmc":"0,13 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-60 dBm to -50 dBm","cmc":"0,089 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-50 dBm to -40 dBm","cmc":"0,085 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"20 dBm to 30 dBm","cmc":"0,060 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"30 dBm to 35 dBm","cmc":"0,13 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"35 dBm to 44 dBm","cmc":"0,22 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,28 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,14 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,098 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,079 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,077 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,075 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,073 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,073 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"20 dBm to 30 dBm","cmc":"0,077 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-100 dBm to -90 dBm","cmc":"1,1 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-90 dBm to -80 dBm","cmc":"0,52 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-80 dBm to -70 dBm","cmc":"0,22 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-60 dBm to -50 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-50 dBm to -40 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-40 dBm to -30 dBm","cmc":"0,11 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-30 dBm to -20 dBm","cmc":"0,098 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-20 dBm to -10 dBm","cmc":"0,097 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-10 dBm to 0 dBm","cmc":"0,095 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"0 dBm to 20 dBm","cmc":"0,095 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"20 dBm to 30 dBm","cmc":"0,098 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-80 dBm to -70 dBm","cmc":"0,37 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-70 dBm to -60 dBm","cmc":"0,18 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-60 dBm to -50 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-50 dBm to -40 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-40 dBm to -30 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-30 dBm to -20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-20 dBm to -10 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-10 dBm to 0 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"0 dBm to 20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"20 dBm to 30 dBm","cmc":"0,12 dB"},{"name":"f = 40 GHz bis 50 GHz","range":"-40 dBm to -30 dBm","cmc":"0,19 dB"},{"name":"f = 40 GHz bis 50 GHz","range":"-30 dBm to -20 dBm","cmc":"0,19 dB"},{"name":"f = 40 GHz bis 50 GHz","range":"-20 dBm to -10 dBm","cmc":"0,15 dB"},{"name":"f = 40 GHz bis 50 GHz","range":"-10 dBm to 0 dBm","cmc":"0,14 dB"},{"name":"f = 40 GHz bis 50 GHz","range":"0 dBm to 20 dBm","cmc":"0,14 dB"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Generatoren Netzwerkanalysatoren Spektrumanalysatoren Funkkommunikationstester Messempfänger Verstärker - Ausgangsleistungspegel Kalibrierung — elektrische HF-Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 10 Hz bis 9 kHz f = 10 Hz bis 9 kHz f = 10 Hz bis 9 kHz f = 10 Hz bis 9 kHz f = 10 Hz bis 9 kHz f = 9 kHz bis 20 kHz f = 9 kHz bis 20 kHz f = 9 kHz bis 20 kHz f = 9 kHz bis 20 kHz f = 9 kHz bis 20 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 40 GHz bis 50 GHz f = 40 GHz bis 50 GHz f = 40 GHz bis 50 GHz f = 40 GHz bis 50 GHz f = 40 GHz bis 50 GHz LMEEiO/32 LMEEiO/39 LMEEiO/40 LMEEiO/48","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Generatoren\nNetzwerkanalysatoren\nSpektrumanalysatoren\nFunkkommunikationstester\nMessempfänger\nVerstärker\n- Ausgangsleistungspegel","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"f = 10 Hz 至 9 kHz","range":"-40 dBm to -30 dBm","cmc":"0,20 dB"},{"name":"f = 10 Hz 至 9 kHz","range":"-30 dBm to -20 dBm","cmc":"0,068 dB"},{"name":"f = 10 Hz 至 9 kHz","range":"-20 dBm to -10 dBm","cmc":"0,029 dB"},{"name":"f = 10 Hz 至 9 kHz","range":"-10 dBm to 0 dBm","cmc":"0,019 dB"},{"name":"f = 10 Hz 至 9 kHz","range":"0 dBm to 30 dBm","cmc":"0,024 dB"},{"name":"f = 9 kHz 至 20 kHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 9 kHz 至 20 kHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 9 kHz 至 20 kHz","range":"-20 dBm to -10 dBm","cmc":"0,029 dB"},{"name":"f = 9 kHz 至 20 kHz","range":"-10 dBm to 0 dBm","cmc":"0,019 dB"},{"name":"f = 9 kHz 至 20 kHz","range":"0 dBm to 30 dBm","cmc":"0,024 dB"},{"name":"f = 20 kHz 至 50 kHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 20 kHz 至 50 kHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 20 kHz 至 50 kHz","range":"-20 dBm to -10 dBm","cmc":"0,034 dB"},{"name":"f = 20 kHz 至 50 kHz","range":"-10 dBm to 0 dBm","cmc":"0,023 dB"},{"name":"f = 20 kHz 至 50 kHz","range":"0 dBm to 30 dBm","cmc":"0,033 dB"},{"name":"f = 50 kHz 至 100 kHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 50 kHz 至 100 kHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 50 kHz 至 100 kHz","range":"-20 dBm to -10 dBm","cmc":"0,041 dB"},{"name":"f = 50 kHz 至 100 kHz","range":"-10 dBm to 0 dBm","cmc":"0,028 dB"},{"name":"f = 50 kHz 至 100 kHz","range":"0 dBm to 30 dBm","cmc":"0,052 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-130 dBm to -120 dBm","cmc":"1,2 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-120 dBm to -110 dBm","cmc":"0,57 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-110 dBm to -100 dBm","cmc":"0,23 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-100 dBm to -90 dBm","cmc":"0,11 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-90 dBm to -80 dBm","cmc":"0,10 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-80 dBm to -70 dBm","cmc":"0,097 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-60 dBm to -50 dBm","cmc":"0,067 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-50 dBm to -40 dBm","cmc":"0,065 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"20 dBm to 30 dBm","cmc":"0,060 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"30 dBm to 45 dBm","cmc":"0,18 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"45 dBm to 52 dBm","cmc":"0,21 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-130 dBm to -120 dBm","cmc":"0,94 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-120 dBm to -110 dBm","cmc":"0,44 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-110 dBm to -100 dBm","cmc":"0,18 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-100 dBm to -90 dBm","cmc":"0,11 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-90 dBm to -80 dBm","cmc":"0,10 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-80 dBm to -70 dBm","cmc":"0,099 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-70 dBm to -60 dBm","cmc":"0,095 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-60 dBm to -50 dBm","cmc":"0,071 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-50 dBm to -40 dBm","cmc":"0,068 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-40 dBm to -30 dBm","cmc":"0,066 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-30 dBm to -20 dBm","cmc":"0,060 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-20 dBm to -10 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-10 dBm to 0 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"0 dBm to 20 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"20 dBm to 35 dBm","cmc":"0,060 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"35 dBm to 45 dBm","cmc":"0,18 dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"45 dBm to 52 dBm","cmc":"0,21 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-120 dBm to -110 dBm","cmc":"0,82 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-110 dBm to -100 dBm","cmc":"0,37 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-100 dBm to -90 dBm","cmc":"0,16 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-90 dBm to -80 dBm","cmc":"0,10 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-80 dBm to -70 dBm","cmc":"0,097 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-60 dBm to -50 dBm","cmc":"0,089 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-50 dBm to -40 dBm","cmc":"0,065 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"20 dBm to 35 dBm","cmc":"0,058 dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"35 dBm to 44 dBm","cmc":"0,18 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-110 dBm to -100 dBm","cmc":"0,76 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,33 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,14 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,097 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,089 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,065 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"20 dBm to 30 dBm","cmc":"0,060 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"30 dBm to 35 dBm","cmc":"0,083 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"35 dBm to 44 dBm","cmc":"0,19 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-90 dBm to -80 dBm","cmc":"0,27 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-80 dBm to -70 dBm","cmc":"0,13 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-60 dBm to -50 dBm","cmc":"0,089 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-50 dBm to -40 dBm","cmc":"0,085 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"20 dBm to 30 dBm","cmc":"0,060 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"30 dBm to 35 dBm","cmc":"0,13 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"35 dBm to 44 dBm","cmc":"0,22 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,28 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,14 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,098 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,079 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,077 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,075 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,073 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,073 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"20 dBm to 30 dBm","cmc":"0,077 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-100 dBm to -90 dBm","cmc":"1,1 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-90 dBm to -80 dBm","cmc":"0,52 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-80 dBm to -70 dBm","cmc":"0,22 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-60 dBm to -50 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-50 dBm to -40 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-40 dBm to -30 dBm","cmc":"0,11 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-30 dBm to -20 dBm","cmc":"0,098 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-20 dBm to -10 dBm","cmc":"0,097 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-10 dBm to 0 dBm","cmc":"0,095 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"0 dBm to 20 dBm","cmc":"0,095 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"20 dBm to 30 dBm","cmc":"0,098 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-80 dBm to -70 dBm","cmc":"0,37 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-70 dBm to -60 dBm","cmc":"0,18 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-60 dBm to -50 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-50 dBm to -40 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-40 dBm to -30 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-30 dBm to -20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-20 dBm to -10 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-10 dBm to 0 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"0 dBm to 20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"20 dBm to 30 dBm","cmc":"0,12 dB"},{"name":"f = 40 GHz 至 50 GHz","range":"-40 dBm to -30 dBm","cmc":"0,19 dB"},{"name":"f = 40 GHz 至 50 GHz","range":"-30 dBm to -20 dBm","cmc":"0,19 dB"},{"name":"f = 40 GHz 至 50 GHz","range":"-20 dBm to -10 dBm","cmc":"0,15 dB"},{"name":"f = 40 GHz 至 50 GHz","range":"-10 dBm to 0 dBm","cmc":"0,14 dB"},{"name":"f = 40 GHz 至 50 GHz","range":"0 dBm to 20 dBm","cmc":"0,14 dB"}],"regulatory_area_zh":"射频电学量","search_zh":"发生器 网络分析仪 频谱分析仪 无线电通信测试仪 测量接收机 放大器 - 输出功率电平 校准 — 射频电学量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 10 Hz 至 9 kHz f = 10 Hz 至 9 kHz f = 10 Hz 至 9 kHz f = 10 Hz 至 9 kHz f = 10 Hz 至 9 kHz f = 9 kHz 至 20 kHz f = 9 kHz 至 20 kHz f = 9 kHz 至 20 kHz f = 9 kHz 至 20 kHz f = 9 kHz 至 20 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 40 GHz 至 50 GHz f = 40 GHz 至 50 GHz f = 40 GHz 至 50 GHz f = 40 GHz 至 50 GHz f = 40 GHz 至 50 GHz LMEEiO/32 LMEEiO/39 LMEEiO/40 LMEEiO/48","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"发生器\n网络分析仪\n频谱分析仪\n无线电通信测试仪\n测量接收机\n放大器\n- 输出功率电平","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"f = 10 Hz až 9 kHz","range":"-40 dBm to -30 dBm","cmc":"0,20 dB"},{"name":"f = 10 Hz až 9 kHz","range":"-30 dBm to -20 dBm","cmc":"0,068 dB"},{"name":"f = 10 Hz až 9 kHz","range":"-20 dBm to -10 dBm","cmc":"0,029 dB"},{"name":"f = 10 Hz až 9 kHz","range":"-10 dBm to 0 dBm","cmc":"0,019 dB"},{"name":"f = 10 Hz až 9 kHz","range":"0 dBm to 30 dBm","cmc":"0,024 dB"},{"name":"f = 9 kHz až 20 kHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 9 kHz až 20 kHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 9 kHz až 20 kHz","range":"-20 dBm to -10 dBm","cmc":"0,029 dB"},{"name":"f = 9 kHz až 20 kHz","range":"-10 dBm to 0 dBm","cmc":"0,019 dB"},{"name":"f = 9 kHz až 20 kHz","range":"0 dBm to 30 dBm","cmc":"0,024 dB"},{"name":"f = 20 kHz až 50 kHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 20 kHz až 50 kHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 20 kHz až 50 kHz","range":"-20 dBm to -10 dBm","cmc":"0,034 dB"},{"name":"f = 20 kHz až 50 kHz","range":"-10 dBm to 0 dBm","cmc":"0,023 dB"},{"name":"f = 20 kHz až 50 kHz","range":"0 dBm to 30 dBm","cmc":"0,033 dB"},{"name":"f = 50 kHz až 100 kHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 50 kHz až 100 kHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 50 kHz až 100 kHz","range":"-20 dBm to -10 dBm","cmc":"0,041 dB"},{"name":"f = 50 kHz až 100 kHz","range":"-10 dBm to 0 dBm","cmc":"0,028 dB"},{"name":"f = 50 kHz až 100 kHz","range":"0 dBm to 30 dBm","cmc":"0,052 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-130 dBm to -120 dBm","cmc":"1,2 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-120 dBm to -110 dBm","cmc":"0,57 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-110 dBm to -100 dBm","cmc":"0,23 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-100 dBm to -90 dBm","cmc":"0,11 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-90 dBm to -80 dBm","cmc":"0,10 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-80 dBm to -70 dBm","cmc":"0,097 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-60 dBm to -50 dBm","cmc":"0,067 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-50 dBm to -40 dBm","cmc":"0,065 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz až 10 MHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 100 kHz až 10 MHz","range":"20 dBm to 30 dBm","cmc":"0,060 dB"},{"name":"f = 100 kHz až 10 MHz","range":"30 dBm to 45 dBm","cmc":"0,18 dB"},{"name":"f = 100 kHz až 10 MHz","range":"45 dBm to 52 dBm","cmc":"0,21 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-130 dBm to -120 dBm","cmc":"0,94 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-120 dBm to -110 dBm","cmc":"0,44 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-110 dBm to -100 dBm","cmc":"0,18 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-100 dBm to -90 dBm","cmc":"0,11 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-90 dBm to -80 dBm","cmc":"0,10 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-80 dBm to -70 dBm","cmc":"0,099 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-70 dBm to -60 dBm","cmc":"0,095 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-60 dBm to -50 dBm","cmc":"0,071 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-50 dBm to -40 dBm","cmc":"0,068 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-40 dBm to -30 dBm","cmc":"0,066 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-30 dBm to -20 dBm","cmc":"0,060 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-20 dBm to -10 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-10 dBm to 0 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"0 dBm to 20 dBm","cmc":"0,059 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"20 dBm to 35 dBm","cmc":"0,060 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"35 dBm to 45 dBm","cmc":"0,18 dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"45 dBm to 52 dBm","cmc":"0,21 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-120 dBm to -110 dBm","cmc":"0,82 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-110 dBm to -100 dBm","cmc":"0,37 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-100 dBm to -90 dBm","cmc":"0,16 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-90 dBm to -80 dBm","cmc":"0,10 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-80 dBm to -70 dBm","cmc":"0,097 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-60 dBm to -50 dBm","cmc":"0,089 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-50 dBm to -40 dBm","cmc":"0,065 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"20 dBm to 35 dBm","cmc":"0,058 dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"35 dBm to 44 dBm","cmc":"0,18 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-110 dBm to -100 dBm","cmc":"0,76 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,33 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,14 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,097 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,089 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,065 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"20 dBm to 30 dBm","cmc":"0,060 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"30 dBm to 35 dBm","cmc":"0,083 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"35 dBm to 44 dBm","cmc":"0,19 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-90 dBm to -80 dBm","cmc":"0,27 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-80 dBm to -70 dBm","cmc":"0,13 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-70 dBm to -60 dBm","cmc":"0,093 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-60 dBm to -50 dBm","cmc":"0,089 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-50 dBm to -40 dBm","cmc":"0,085 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-40 dBm to -30 dBm","cmc":"0,062 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-30 dBm to -20 dBm","cmc":"0,057 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-20 dBm to -10 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-10 dBm to 0 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"0 dBm to 20 dBm","cmc":"0,055 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"20 dBm to 30 dBm","cmc":"0,060 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"30 dBm to 35 dBm","cmc":"0,13 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"35 dBm to 44 dBm","cmc":"0,22 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,28 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,14 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,098 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,079 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,077 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,075 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,073 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,073 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"20 dBm to 30 dBm","cmc":"0,077 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-100 dBm to -90 dBm","cmc":"1,1 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-90 dBm to -80 dBm","cmc":"0,52 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-80 dBm to -70 dBm","cmc":"0,22 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-60 dBm to -50 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-50 dBm to -40 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-40 dBm to -30 dBm","cmc":"0,11 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-30 dBm to -20 dBm","cmc":"0,098 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-20 dBm to -10 dBm","cmc":"0,097 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-10 dBm to 0 dBm","cmc":"0,095 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"0 dBm to 20 dBm","cmc":"0,095 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"20 dBm to 30 dBm","cmc":"0,098 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-80 dBm to -70 dBm","cmc":"0,37 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-70 dBm to -60 dBm","cmc":"0,18 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-60 dBm to -50 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-50 dBm to -40 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-40 dBm to -30 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-30 dBm to -20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-20 dBm to -10 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-10 dBm to 0 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"0 dBm to 20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"20 dBm to 30 dBm","cmc":"0,12 dB"},{"name":"f = 40 GHz až 50 GHz","range":"-40 dBm to -30 dBm","cmc":"0,19 dB"},{"name":"f = 40 GHz až 50 GHz","range":"-30 dBm to -20 dBm","cmc":"0,19 dB"},{"name":"f = 40 GHz až 50 GHz","range":"-20 dBm to -10 dBm","cmc":"0,15 dB"},{"name":"f = 40 GHz až 50 GHz","range":"-10 dBm to 0 dBm","cmc":"0,14 dB"},{"name":"f = 40 GHz až 50 GHz","range":"0 dBm to 20 dBm","cmc":"0,14 dB"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Generátory Obvodové analyzátory Spektrální analyzátory Radiokomunikační testery Měřicí přijímače Zesilovače - úroveň výstupního výkonu Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 10 Hz až 9 kHz f = 10 Hz až 9 kHz f = 10 Hz až 9 kHz f = 10 Hz až 9 kHz f = 10 Hz až 9 kHz f = 9 kHz až 20 kHz f = 9 kHz až 20 kHz f = 9 kHz až 20 kHz f = 9 kHz až 20 kHz f = 9 kHz až 20 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 40 GHz až 50 GHz f = 40 GHz až 50 GHz f = 40 GHz až 50 GHz f = 40 GHz až 50 GHz f = 40 GHz až 50 GHz LMEEiO/32 LMEEiO/39 LMEEiO/40 LMEEiO/48","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Generátory\nObvodové analyzátory\nSpektrální analyzátory\nRadiokomunikační testery\nMěřicí přijímače\nZesilovače\n- úroveň výstupního výkonu"},{"_id":"1f934ce3fe3d5a2a6f3e25b4","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki mocy\n- poziom mocy na wyjściu odniesienia","test_object_en":"Power meters\n- power level at the reference output","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"f = 50 MHz","range":"1 mW","cmc":"0,0049 mW"},{"name":"f = 50 MHz","range":"0 dBm","cmc":"0,022 dB"}],"parameters_en":[{"name":"f = 50 MHz","range":"1 mW","cmc":"0,0049 mW"},{"name":"f = 50 MHz","range":"0 dBm","cmc":"0,022 dB"}],"technique":"Procedura wewnętrzna; Metoda bezposrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezposrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 50 MHz 1 mW CMC 0,0049 mW\nf = 50 MHz 0 dBm CMC 0,022 dB\nProcedura wewnętrzna; Metoda bezposrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/33","norm_bases":["LMEEiO/33"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy\n- poziom mocy na wyjściu odniesienia Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 50 MHz 1 mW CMC 0,0049 mW\nf = 50 MHz 0 dBm CMC 0,022 dB\nProcedura wewnętrzna; Metoda bezposrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/33 Mierniki mocy\n- poziom mocy na wyjsciu odniesienia Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\nf = 50 MHz 1 mW CMC 0,0049 mW\nf = 50 MHz 0 dBm CMC 0,022 dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/33","search_en":"Power meters - power level at the reference output Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 MHz f = 50 MHz LMEEiO/33","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":42,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"f = 50 MHz","range":"1 mW","cmc":"0,0049 mW"},{"name":"f = 50 MHz","range":"0 dBm","cmc":"0,022 dB"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Leistungsmesser - Leistungspegel am Referenzausgang Kalibrierung — elektrische HF-Größen Internes Verfahren; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 MHz f = 50 MHz LMEEiO/33","technique_de":"Internes Verfahren; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Leistungsmesser\n- Leistungspegel am Referenzausgang","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"f = 50 MHz","range":"1 mW","cmc":"0,0049 mW"},{"name":"f = 50 MHz","range":"0 dBm","cmc":"0,022 dB"}],"regulatory_area_zh":"射频电学量","search_zh":"功率计 - 参考输出端功率电平 校准 — 射频电学量 内部程序; 直接法; 在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 MHz f = 50 MHz LMEEiO/33","technique_zh":"内部程序; 直接法; 在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"功率计\n- 参考输出端功率电平","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"f = 50 MHz","range":"1 mW","cmc":"0,0049 mW"},{"name":"f = 50 MHz","range":"0 dBm","cmc":"0,022 dB"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Měřiče výkonu - úroveň výkonu na referenčním výstupu Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; V trvalé lokalitě (S) i mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 MHz f = 50 MHz LMEEiO/33","technique_cs":"Vnitřní postup; Přímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče výkonu\n- úroveň výkonu na referenčním výstupu"},{"_id":"7ca0acab49162c1b13c4fd24","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki mocy\nCzujniki mocy\nAnalizatory obwodów\nAnalizatory widma\nAnalizatory systemów antenowych i kablowych\nAnalizatory modulacji analogowych\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\n- poziom mocy mierzonej","test_object_en":"Power meters\nPower sensors\nNetwork analysers\nSpectrum analysers\nAntenna and cable system analysers\nAnalogue modulation analysers\nRadio communication testers\nMeasuring receivers\n- measured power level","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"f = 50 MHz","range":"-10 dBm do 10 dBm","cmc":"0,076 dB"},{"name":"f = 10 Hz do 9 kHz","range":"-40 dBm do -30 dBm","cmc":"0,21 dB"},{"name":"f = 10 Hz do 9 kHz","range":"-30 dBm do -20 dBm","cmc":"0,097 dB"},{"name":"f = 10 Hz do 9 kHz","range":"-20 dBm do -10 dBm","cmc":"0,075 dB"},{"name":"f = 10 Hz do 9 kHz","range":"-10 dBm do 0 dBm","cmc":"0,072 dB"},{"name":"f = 10 Hz do 9 kHz","range":"0 dBm do 20 dBm","cmc":"0,073 dB"},{"name":"f = 9 kHz do 100 kHz","range":"-40 dBm do -30 dBm","cmc":"0,16 dB"},{"name":"f = 9 kHz do 100 kHz","range":"-30 dBm do -20 dBm","cmc":"0,090 dB"},{"name":"f = 9 kHz do 100 kHz","range":"-20 dBm do -10 dBm","cmc":"0,081 dB"},{"name":"f = 9 kHz do 100 kHz","range":"-10 dBm do 0 dBm","cmc":"0,075 dB"},{"name":"f = 9 kHz do 100 kHz","range":"0 dBm do 20 dBm","cmc":"0,087 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-130 dBm do -120 dBm","cmc":"1,20 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-120 dBm do -110 dBm","cmc":"0,57 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-110 dBm do -100 dBm","cmc":"0,24 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-100 dBm do -90 dBm","cmc":"0,13 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-90 dBm do -80 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-80 dBm do -70 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-70 dBm do -60 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-60 dBm do -50 dBm","cmc":"0,096 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-50 dBm do -40 dBm","cmc":"0,095 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-40 dBm do -30 dBm","cmc":"0,093 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-30 dBm do -20 dBm","cmc":"0,090 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-20 dBm do -10 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-10 dBm do 0 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz do 10 MHz","range":"0 dBm do 20 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz do 10 MHz","range":"20 dBm do 30 dBm","cmc":"0,092 dB"},{"name":"f = 100 kHz do 10 MHz","range":"30 dBm do 45 dBm","cmc":"0,19 dB"},{"name":"f = 100 kHz do 10 MHz","range":"45 dBm do 52 dBm","cmc":"0,22 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-130 dBm do -120 dBm","cmc":"0,94 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-120 dBm do -110 dBm","cmc":"0,45 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-110 dBm do -100 dBm","cmc":"0,19 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-100 dBm do -90 dBm","cmc":"0,13 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-90 dBm do -80 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-80 dBm do -70 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-70 dBm do -60 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-60 dBm do -50 dBm","cmc":"0,099 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-50 dBm do -40 dBm","cmc":"0,097 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-40 dBm do -30 dBm","cmc":"0,096 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-30 dBm do -20 dBm","cmc":"0,092 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-20 dBm do -10 dBm","cmc":"0,091 dB"},{"name":"f = 10 MHz do 500 MHz","range":"-10 dBm do 0 dBm","cmc":"0,086 dB"},{"name":"f = 10 MHz do 500 MHz","range":"0 dBm do 20 dBm","cmc":"0,086 dB"},{"name":"f = 10 MHz do 500 MHz","range":"20 dBm do 35 dBm","cmc":"0,092 dB"},{"name":"f = 10 MHz do 500 MHz","range":"35 dBm do 45 dBm","cmc":"0,19 dB"},{"name":"f = 10 MHz do 500 MHz","range":"45 dBm do 52 dBm","cmc":"0,22 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-130 dBm do -120 dBm","cmc":"0,94 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-120 dBm do -110 dBm","cmc":"0,45 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-110 dBm do -100 dBm","cmc":"0,19 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-100 dBm do -90 dBm","cmc":"0,13 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-90 dBm do -80 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-80 dBm do -70 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-70 dBm do -60 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-60 dBm do -50 dBm","cmc":"0,099 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-50 dBm do -40 dBm","cmc":"0,097 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-40 dBm do -30 dBm","cmc":"0,096 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-30 dBm do -20 dBm","cmc":"0,092 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-20 dBm do -10 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"-10 dBm do 0 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"0 dBm do 20 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"20 dBm do 35 dBm","cmc":"0,092 dB"},{"name":"f = 500 MHz do 3,05 GHz","range":"35 dBm do 44 dBm","cmc":"0,19 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"-120 dBm do -110 dBm","cmc":"0,82 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"-110 dBm do -100 dBm","cmc":"0,38 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"-100 dBm do -90 dBm","cmc":"0,17 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"-90 dBm do -80 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"-80 dBm do -70 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"-70 dBm do -60 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"-60 dBm do -50 dBm","cmc":"0,11 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"-50 dBm do -40 dBm","cmc":"0,095 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"-40 dBm do -30 dBm","cmc":"0,093 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"-30 dBm do -20 dBm","cmc":"0,090 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"-20 dBm do -10 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"-10 dBm do 0 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"0 dBm do 20 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"20 dBm do 35 dBm","cmc":"0,090 dB"},{"name":"f = 3,05 GHz do 4 GHz","range":"35 dBm do 40 dBm","cmc":"0,19 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"-120 dBm do -110 dBm","cmc":"0,82 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"-110 dBm do -100 dBm","cmc":"0,38 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"-100 dBm do -90 dBm","cmc":"0,17 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"-90 dBm do -80 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"-80 dBm do -70 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"-70 dBm do -60 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"-60 dBm do -50 dBm","cmc":"0,11 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"-50 dBm do -40 dBm","cmc":"0,095 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"-40 dBm do -30 dBm","cmc":"0,093 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"-30 dBm do -20 dBm","cmc":"0,090 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"-20 dBm do -10 dBm","cmc":"0,088 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"-10 dBm do 0 dBm","cmc":"0,088 dB"},{"name":"f = 4 GHz do 6,6 GHz","range":"0 dBm do 20 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-110 dBm do -100 dBm","cmc":"0,76 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-100 dBm do -90 dBm","cmc":"0,34 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-90 dBm do -80 dBm","cmc":"0,16 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-80 dBm do -70 dBm","cmc":"0,12 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-70 dBm do -60 dBm","cmc":"0,12 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-60 dBm do -50 dBm","cmc":"0,11 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-50 dBm do -40 dBm","cmc":"0,095 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-40 dBm do -30 dBm","cmc":"0,093 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-30 dBm do -20 dBm","cmc":"0,090 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-20 dBm do -10 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-10 dBm do 0 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"0 dBm do 20 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-100 dBm do -90 dBm","cmc":"0,65 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-90 dBm do -80 dBm","cmc":"0,28 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-80 dBm do -70 dBm","cmc":"0,15 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-70 dBm do -60 dBm","cmc":"0,12 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-60 dBm do -50 dBm","cmc":"0,11 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-50 dBm do -40 dBm","cmc":"0,11 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-40 dBm do -30 dBm","cmc":"0,093 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-30 dBm do -20 dBm","cmc":"0,090 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-20 dBm do -10 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"-10 dBm do 0 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz do 18 GHz","range":"0 dBm do 20 dBm","cmc":"0,088 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-100 dBm do -90 dBm","cmc":"0,65 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-90 dBm do -80 dBm","cmc":"0,29 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-80 dBm do -70 dBm","cmc":"0,16 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-70 dBm do -60 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-60 dBm do -50 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-50 dBm do -40 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-40 dBm do -30 dBm","cmc":"0,11 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-30 dBm do -20 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-20 dBm do -10 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"-10 dBm do 0 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz do 19,2 GHz","range":"0 dBm do 20 dBm","cmc":"0,10 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-100 dBm do -90 dBm","cmc":"1,1 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-90 dBm do -80 dBm","cmc":"0,52 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-80 dBm do -70 dBm","cmc":"0,23 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-70 dBm do -60 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-60 dBm do -50 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-50 dBm do -40 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-40 dBm do -30 dBm","cmc":"0,13 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-30 dBm do -20 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-20 dBm do -10 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-10 dBm do 0 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"0 dBm do 20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-80 dBm do -70 dBm","cmc":"0,38 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-70 dBm do -60 dBm","cmc":"0,19 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-60 dBm do -50 dBm","cmc":"0,16 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-50 dBm do -40 dBm","cmc":"0,16 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-40 dBm do -30 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-30 dBm do -20 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-20 dBm do -10 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-10 dBm do 0 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"0 dBm do 20 dBm","cmc":"0,14 dB"},{"name":"f = 40 GHz do 50 GHz","range":"-40 dBm do -30 dBm","cmc":"0,20 dB"},{"name":"f = 40 GHz do 50 GHz","range":"-30 dBm do -20 dBm","cmc":"0,20 dB"},{"name":"f = 40 GHz do 50 GHz","range":"-20 dBm do -10 dBm","cmc":"0,17 dB"},{"name":"f = 40 GHz do 50 GHz","range":"-10 dBm do 0 dBm","cmc":"0,16 dB"},{"name":"f = 40 GHz do 50 GHz","range":"0 dBm do 20 dBm","cmc":"0,16 dB"}],"parameters_en":[{"name":"f = 50 MHz","range":"-10 dBm to 10 dBm","cmc":"0,076 dB"},{"name":"f = 10 Hz to 9 kHz","range":"-40 dBm to -30 dBm","cmc":"0,21 dB"},{"name":"f = 10 Hz to 9 kHz","range":"-30 dBm to -20 dBm","cmc":"0,097 dB"},{"name":"f = 10 Hz to 9 kHz","range":"-20 dBm to -10 dBm","cmc":"0,075 dB"},{"name":"f = 10 Hz to 9 kHz","range":"-10 dBm to 0 dBm","cmc":"0,072 dB"},{"name":"f = 10 Hz to 9 kHz","range":"0 dBm to 20 dBm","cmc":"0,073 dB"},{"name":"f = 9 kHz to 100 kHz","range":"-40 dBm to -30 dBm","cmc":"0,16 dB"},{"name":"f = 9 kHz to 100 kHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 9 kHz to 100 kHz","range":"-20 dBm to -10 dBm","cmc":"0,081 dB"},{"name":"f = 9 kHz to 100 kHz","range":"-10 dBm to 0 dBm","cmc":"0,075 dB"},{"name":"f = 9 kHz to 100 kHz","range":"0 dBm to 20 dBm","cmc":"0,087 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-130 dBm to -120 dBm","cmc":"1,20 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-120 dBm to -110 dBm","cmc":"0,57 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-110 dBm to -100 dBm","cmc":"0,24 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-100 dBm to -90 dBm","cmc":"0,13 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-60 dBm to -50 dBm","cmc":"0,096 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz to 10 MHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz to 10 MHz","range":"20 dBm to 30 dBm","cmc":"0,092 dB"},{"name":"f = 100 kHz to 10 MHz","range":"30 dBm to 45 dBm","cmc":"0,19 dB"},{"name":"f = 100 kHz to 10 MHz","range":"45 dBm to 52 dBm","cmc":"0,22 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-130 dBm to -120 dBm","cmc":"0,94 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-120 dBm to -110 dBm","cmc":"0,45 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-110 dBm to -100 dBm","cmc":"0,19 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-100 dBm to -90 dBm","cmc":"0,13 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-60 dBm to -50 dBm","cmc":"0,099 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-50 dBm to -40 dBm","cmc":"0,097 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-40 dBm to -30 dBm","cmc":"0,096 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-30 dBm to -20 dBm","cmc":"0,092 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-20 dBm to -10 dBm","cmc":"0,091 dB"},{"name":"f = 10 MHz to 500 MHz","range":"-10 dBm to 0 dBm","cmc":"0,086 dB"},{"name":"f = 10 MHz to 500 MHz","range":"0 dBm to 20 dBm","cmc":"0,086 dB"},{"name":"f = 10 MHz to 500 MHz","range":"20 dBm to 35 dBm","cmc":"0,092 dB"},{"name":"f = 10 MHz to 500 MHz","range":"35 dBm to 45 dBm","cmc":"0,19 dB"},{"name":"f = 10 MHz to 500 MHz","range":"45 dBm to 52 dBm","cmc":"0,22 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-130 dBm to -120 dBm","cmc":"0,94 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-120 dBm to -110 dBm","cmc":"0,45 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-110 dBm to -100 dBm","cmc":"0,19 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-100 dBm to -90 dBm","cmc":"0,13 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-60 dBm to -50 dBm","cmc":"0,099 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-50 dBm to -40 dBm","cmc":"0,097 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-40 dBm to -30 dBm","cmc":"0,096 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-30 dBm to -20 dBm","cmc":"0,092 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-20 dBm to -10 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"-10 dBm to 0 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"0 dBm to 20 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"20 dBm to 35 dBm","cmc":"0,092 dB"},{"name":"f = 500 MHz to 3,05 GHz","range":"35 dBm to 44 dBm","cmc":"0,19 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"-120 dBm to -110 dBm","cmc":"0,82 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"-110 dBm to -100 dBm","cmc":"0,38 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"-100 dBm to -90 dBm","cmc":"0,17 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"20 dBm to 35 dBm","cmc":"0,090 dB"},{"name":"f = 3,05 GHz to 4 GHz","range":"35 dBm to 40 dBm","cmc":"0,19 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"-120 dBm to -110 dBm","cmc":"0,82 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"-110 dBm to -100 dBm","cmc":"0,38 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"-100 dBm to -90 dBm","cmc":"0,17 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 4 GHz to 6,6 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-110 dBm to -100 dBm","cmc":"0,76 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,34 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,16 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-90 dBm to -80 dBm","cmc":"0,28 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-80 dBm to -70 dBm","cmc":"0,15 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-50 dBm to -40 dBm","cmc":"0,11 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz to 18 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,29 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,16 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,11 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz to 19,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,10 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-100 dBm to -90 dBm","cmc":"1,1 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-90 dBm to -80 dBm","cmc":"0,52 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-80 dBm to -70 dBm","cmc":"0,23 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-70 dBm to -60 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-60 dBm to -50 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-50 dBm to -40 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-40 dBm to -30 dBm","cmc":"0,13 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-30 dBm to -20 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-20 dBm to -10 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-10 dBm to 0 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"0 dBm to 20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-80 dBm to -70 dBm","cmc":"0,38 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-70 dBm to -60 dBm","cmc":"0,19 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-60 dBm to -50 dBm","cmc":"0,16 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-50 dBm to -40 dBm","cmc":"0,16 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-30 dBm to -20 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-20 dBm to -10 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-10 dBm to 0 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"0 dBm to 20 dBm","cmc":"0,14 dB"},{"name":"f = 40 GHz to 50 GHz","range":"-40 dBm to -30 dBm","cmc":"0,20 dB"},{"name":"f = 40 GHz to 50 GHz","range":"-30 dBm to -20 dBm","cmc":"0,20 dB"},{"name":"f = 40 GHz to 50 GHz","range":"-20 dBm to -10 dBm","cmc":"0,17 dB"},{"name":"f = 40 GHz to 50 GHz","range":"-10 dBm to 0 dBm","cmc":"0,16 dB"},{"name":"f = 40 GHz to 50 GHz","range":"0 dBm to 20 dBm","cmc":"0,16 dB"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 50 MHz -10 dBm do 10 dBm CMC 0,076 dB\nf = 10 Hz do 9 kHz -40 dBm do -30 dBm CMC 0,21 dB\nf = 10 Hz do 9 kHz -30 dBm do -20 dBm CMC 0,097 dB\nf = 10 Hz do 9 kHz -20 dBm do -10 dBm CMC 0,075 dB\nf = 10 Hz do 9 kHz -10 dBm do 0 dBm CMC 0,072 dB\nf = 10 Hz do 9 kHz 0 dBm do 20 dBm CMC 0,073 dB\nf = 9 kHz do 100 kHz -40 dBm do -30 dBm CMC 0,16 dB\nf = 9 kHz do 100 kHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 9 kHz do 100 kHz -20 dBm do -10 dBm CMC 0,081 dB\nf = 9 kHz do 100 kHz -10 dBm do 0 dBm CMC 0,075 dB\nf = 9 kHz do 100 kHz 0 dBm do 20 dBm CMC 0,087 dB\nf = 100 kHz do 10 MHz -130 dBm do -120 dBm CMC 1,20 dB\nf = 100 kHz do 10 MHz -120 dBm do -110 dBm CMC 0,57 dB\nf = 100 kHz do 10 MHz -110 dBm do -100 dBm CMC 0,24 dB\nf = 100 kHz do 10 MHz -100 dBm do -90 dBm CMC 0,13 dB\nf = 100 kHz do 10 MHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 100 kHz do 10 MHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 100 kHz do 10 MHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 100 kHz do 10 MHz -60 dBm do -50 dBm CMC 0,096 dB\nf = 100 kHz do 10 MHz -50 dBm do -40 dBm CMC 0,095 dB\nf = 100 kHz do 10 MHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 100 kHz do 10 MHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 100 kHz do 10 MHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 100 kHz do 10 MHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 100 kHz do 10 MHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 100 kHz do 10 MHz 20 dBm do 30 dBm CMC 0,092 dB\nf = 100 kHz do 10 MHz 30 dBm do 45 dBm CMC 0,19 dB\nf = 100 kHz do 10 MHz 45 dBm do 52 dBm CMC 0,22 dB\nf = 10 MHz do 500 MHz -130 dBm do -120 dBm CMC 0,94 dB\nf = 10 MHz do 500 MHz -120 dBm do -110 dBm CMC 0,45 dB\nf = 10 MHz do 500 MHz -110 dBm do -100 dBm CMC 0,19 dB\nf = 10 MHz do 500 MHz -100 dBm do -90 dBm CMC 0,13 dB\nf = 10 MHz do 500 MHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 10 MHz do 500 MHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 10 MHz do 500 MHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 10 MHz do 500 MHz -60 dBm do -50 dBm CMC 0,099 dB\nf = 10 MHz do 500 MHz -50 dBm do -40 dBm CMC 0,097 dB\nf = 10 MHz do 500 MHz -40 dBm do -30 dBm CMC 0,096 dB\nf = 10 MHz do 500 MHz -30 dBm do -20 dBm CMC 0,092 dB\nf = 10 MHz do 500 MHz -20 dBm do -10 dBm CMC 0,091 dB\nf = 10 MHz do 500 MHz -10 dBm do 0 dBm CMC 0,086 dB\nf = 10 MHz do 500 MHz 0 dBm do 20 dBm CMC 0,086 dB\nf = 10 MHz do 500 MHz 20 dBm do 35 dBm CMC 0,092 dB\nf = 10 MHz do 500 MHz 35 dBm do 45 dBm CMC 0,19 dB\nf = 10 MHz do 500 MHz 45 dBm do 52 dBm CMC 0,22 dB\nf = 500 MHz do 3,05 GHz -130 dBm do -120 dBm CMC 0,94 dB\nf = 500 MHz do 3,05 GHz -120 dBm do -110 dBm CMC 0,45 dB\nf = 500 MHz do 3,05 GHz -110 dBm do -100 dBm CMC 0,19 dB\nf = 500 MHz do 3,05 GHz -100 dBm do -90 dBm CMC 0,13 dB\nf = 500 MHz do 3,05 GHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 500 MHz do 3,05 GHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 500 MHz do 3,05 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 500 MHz do 3,05 GHz -60 dBm do -50 dBm CMC 0,099 dB\nf = 500 MHz do 3,05 GHz -50 dBm do -40 dBm CMC 0,097 dB\nf = 500 MHz do 3,05 GHz -40 dBm do -30 dBm CMC 0,096 dB\nf = 500 MHz do 3,05 GHz -30 dBm do -20 dBm CMC 0,092 dB\nf = 500 MHz do 3,05 GHz -20 dBm do -10 dBm CMC 0,091 dB\nf = 500 MHz do 3,05 GHz -10 dBm do 0 dBm CMC 0,091 dB\nf = 500 MHz do 3,05 GHz 0 dBm do 20 dBm CMC 0,091 dB\nf = 500 MHz do 3,05 GHz 20 dBm do 35 dBm CMC 0,092 dB\nf = 500 MHz do 3,05 GHz 35 dBm do 44 dBm CMC 0,19 dB\nf = 3,05 GHz do 4 GHz -120 dBm do -110 dBm CMC 0,82 dB\nf = 3,05 GHz do 4 GHz -110 dBm do -100 dBm CMC 0,38 dB\nf = 3,05 GHz do 4 GHz -100 dBm do -90 dBm CMC 0,17 dB\nf = 3,05 GHz do 4 GHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 3,05 GHz do 4 GHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 3,05 GHz do 4 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 3,05 GHz do 4 GHz -60 dBm do -50 dBm CMC 0,11 dB\nf = 3,05 GHz do 4 GHz -50 dBm do -40 dBm CMC 0,095 dB\nf = 3,05 GHz do 4 GHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 3,05 GHz do 4 GHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 3,05 GHz do 4 GHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 3,05 GHz do 4 GHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 3,05 GHz do 4 GHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 3,05 GHz do 4 GHz 20 dBm do 35 dBm CMC 0,090 dB\nf = 3,05 GHz do 4 GHz 35 dBm do 40 dBm CMC 0,19 dB\nf = 4 GHz do 6,6 GHz -120 dBm do -110 dBm CMC 0,82 dB\nf = 4 GHz do 6,6 GHz -110 dBm do -100 dBm CMC 0,38 dB\nf = 4 GHz do 6,6 GHz -100 dBm do -90 dBm CMC 0,17 dB\nf = 4 GHz do 6,6 GHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 4 GHz do 6,6 GHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 4 GHz do 6,6 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 4 GHz do 6,6 GHz -60 dBm do -50 dBm CMC 0,11 dB\nf = 4 GHz do 6,6 GHz -50 dBm do -40 dBm CMC 0,095 dB\nf = 4 GHz do 6,6 GHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 4 GHz do 6,6 GHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 4 GHz do 6,6 GHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 4 GHz do 6,6 GHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 4 GHz do 6,6 GHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 6,6 GHz do 13,2 GHz -110 dBm do -100 dBm CMC 0,76 dB\nf = 6,6 GHz do 13,2 GHz -100 dBm do -90 dBm CMC 0,34 dB\nf = 6,6 GHz do 13,2 GHz -90 dBm do -80 dBm CMC 0,16 dB\nf = 6,6 GHz do 13,2 GHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 6,6 GHz do 13,2 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 6,6 GHz do 13,2 GHz -60 dBm do -50 dBm CMC 0,11 dB\nf = 6,6 GHz do 13,2 GHz -50 dBm do -40 dBm CMC 0,095 dB\nf = 6,6 GHz do 13,2 GHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 6,6 GHz do 13,2 GHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 6,6 GHz do 13,2 GHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 6,6 GHz do 13,2 GHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 6,6 GHz do 13,2 GHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 13,2 GHz do 18 GHz -100 dBm do -90 dBm CMC 0,65 dB\nf = 13,2 GHz do 18 GHz -90 dBm do -80 dBm CMC 0,28 dB\nf = 13,2 GHz do 18 GHz -80 dBm do -70 dBm CMC 0,15 dB\nf = 13,2 GHz do 18 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 13,2 GHz do 18 GHz -60 dBm do -50 dBm CMC 0,11 dB\nf = 13,2 GHz do 18 GHz -50 dBm do -40 dBm CMC 0,11 dB\nf = 13,2 GHz do 18 GHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 13,2 GHz do 18 GHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 13,2 GHz do 18 GHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 13,2 GHz do 18 GHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 13,2 GHz do 18 GHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 18 GHz do 19,2 GHz -100 dBm do -90 dBm CMC 0,65 dB\nf = 18 GHz do 19,2 GHz -90 dBm do -80 dBm CMC 0,29 dB\nf = 18 GHz do 19,2 GHz -80 dBm do -70 dBm CMC 0,16 dB\nf = 18 GHz do 19,2 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 18 GHz do 19,2 GHz -60 dBm do -50 dBm CMC 0,12 dB\nf = 18 GHz do 19,2 GHz -50 dBm do -40 dBm CMC 0,12 dB\nf = 18 GHz do 19,2 GHz -40 dBm do -30 dBm CMC 0,11 dB\nf = 18 GHz do 19,2 GHz -30 dBm do -20 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz -20 dBm do -10 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz -10 dBm do 0 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz 0 dBm do 20 dBm CMC 0,10 dB\nf = 19,2 GHz do 26,5 GHz -100 dBm do -90 dBm CMC 1,1 dB\nf = 19,2 GHz do 26,5 GHz -90 dBm do -80 dBm CMC 0,52 dB\nf = 19,2 GHz do 26,5 GHz -80 dBm do -70 dBm CMC 0,23 dB\nf = 19,2 GHz do 26,5 GHz -70 dBm do -60 dBm CMC 0,14 dB\nf = 19,2 GHz do 26,5 GHz -60 dBm do -50 dBm CMC 0,14 dB\nf = 19,2 GHz do 26,5 GHz -50 dBm do -40 dBm CMC 0,14 dB\nf = 19,2 GHz do 26,5 GHz -40 dBm do -30 dBm CMC 0,13 dB\nf = 19,2 GHz do 26,5 GHz -30 dBm do -20 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -20 dBm do -10 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -10 dBm do 0 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz 0 dBm do 20 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz -80 dBm do -70 dBm CMC 0,38 dB\nf = 26,5 GHz do 40 GHz -70 dBm do -60 dBm CMC 0,19 dB\nf = 26,5 GHz do 40 GHz -60 dBm do -50 dBm CMC 0,16 dB\nf = 26,5 GHz do 40 GHz -50 dBm do -40 dBm CMC 0,16 dB\nf = 26,5 GHz do 40 GHz -40 dBm do -30 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -30 dBm do -20 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -20 dBm do -10 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -10 dBm do 0 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz 0 dBm do 20 dBm CMC 0,14 dB\nf = 40 GHz do 50 GHz -40 dBm do -30 dBm CMC 0,20 dB\nf = 40 GHz do 50 GHz -30 dBm do -20 dBm CMC 0,20 dB\nf = 40 GHz do 50 GHz -20 dBm do -10 dBm CMC 0,17 dB\nf = 40 GHz do 50 GHz -10 dBm do 0 dBm CMC 0,16 dB\nf = 40 GHz do 50 GHz 0 dBm do 20 dBm CMC 0,16 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/48","norm_bases":["LMEEiO/32","LMEEiO/33","LMEEiO/39","LMEEiO/40","LMEEiO/48"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy\nCzujniki mocy\nAnalizatory obwodów\nAnalizatory widma\nAnalizatory systemów antenowych i kablowych\nAnalizatory modulacji analogowych\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\n- poziom mocy mierzonej Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 50 MHz -10 dBm do 10 dBm CMC 0,076 dB\nf = 10 Hz do 9 kHz -40 dBm do -30 dBm CMC 0,21 dB\nf = 10 Hz do 9 kHz -30 dBm do -20 dBm CMC 0,097 dB\nf = 10 Hz do 9 kHz -20 dBm do -10 dBm CMC 0,075 dB\nf = 10 Hz do 9 kHz -10 dBm do 0 dBm CMC 0,072 dB\nf = 10 Hz do 9 kHz 0 dBm do 20 dBm CMC 0,073 dB\nf = 9 kHz do 100 kHz -40 dBm do -30 dBm CMC 0,16 dB\nf = 9 kHz do 100 kHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 9 kHz do 100 kHz -20 dBm do -10 dBm CMC 0,081 dB\nf = 9 kHz do 100 kHz -10 dBm do 0 dBm CMC 0,075 dB\nf = 9 kHz do 100 kHz 0 dBm do 20 dBm CMC 0,087 dB\nf = 100 kHz do 10 MHz -130 dBm do -120 dBm CMC 1,20 dB\nf = 100 kHz do 10 MHz -120 dBm do -110 dBm CMC 0,57 dB\nf = 100 kHz do 10 MHz -110 dBm do -100 dBm CMC 0,24 dB\nf = 100 kHz do 10 MHz -100 dBm do -90 dBm CMC 0,13 dB\nf = 100 kHz do 10 MHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 100 kHz do 10 MHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 100 kHz do 10 MHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 100 kHz do 10 MHz -60 dBm do -50 dBm CMC 0,096 dB\nf = 100 kHz do 10 MHz -50 dBm do -40 dBm CMC 0,095 dB\nf = 100 kHz do 10 MHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 100 kHz do 10 MHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 100 kHz do 10 MHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 100 kHz do 10 MHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 100 kHz do 10 MHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 100 kHz do 10 MHz 20 dBm do 30 dBm CMC 0,092 dB\nf = 100 kHz do 10 MHz 30 dBm do 45 dBm CMC 0,19 dB\nf = 100 kHz do 10 MHz 45 dBm do 52 dBm CMC 0,22 dB\nf = 10 MHz do 500 MHz -130 dBm do -120 dBm CMC 0,94 dB\nf = 10 MHz do 500 MHz -120 dBm do -110 dBm CMC 0,45 dB\nf = 10 MHz do 500 MHz -110 dBm do -100 dBm CMC 0,19 dB\nf = 10 MHz do 500 MHz -100 dBm do -90 dBm CMC 0,13 dB\nf = 10 MHz do 500 MHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 10 MHz do 500 MHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 10 MHz do 500 MHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 10 MHz do 500 MHz -60 dBm do -50 dBm CMC 0,099 dB\nf = 10 MHz do 500 MHz -50 dBm do -40 dBm CMC 0,097 dB\nf = 10 MHz do 500 MHz -40 dBm do -30 dBm CMC 0,096 dB\nf = 10 MHz do 500 MHz -30 dBm do -20 dBm CMC 0,092 dB\nf = 10 MHz do 500 MHz -20 dBm do -10 dBm CMC 0,091 dB\nf = 10 MHz do 500 MHz -10 dBm do 0 dBm CMC 0,086 dB\nf = 10 MHz do 500 MHz 0 dBm do 20 dBm CMC 0,086 dB\nf = 10 MHz do 500 MHz 20 dBm do 35 dBm CMC 0,092 dB\nf = 10 MHz do 500 MHz 35 dBm do 45 dBm CMC 0,19 dB\nf = 10 MHz do 500 MHz 45 dBm do 52 dBm CMC 0,22 dB\nf = 500 MHz do 3,05 GHz -130 dBm do -120 dBm CMC 0,94 dB\nf = 500 MHz do 3,05 GHz -120 dBm do -110 dBm CMC 0,45 dB\nf = 500 MHz do 3,05 GHz -110 dBm do -100 dBm CMC 0,19 dB\nf = 500 MHz do 3,05 GHz -100 dBm do -90 dBm CMC 0,13 dB\nf = 500 MHz do 3,05 GHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 500 MHz do 3,05 GHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 500 MHz do 3,05 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 500 MHz do 3,05 GHz -60 dBm do -50 dBm CMC 0,099 dB\nf = 500 MHz do 3,05 GHz -50 dBm do -40 dBm CMC 0,097 dB\nf = 500 MHz do 3,05 GHz -40 dBm do -30 dBm CMC 0,096 dB\nf = 500 MHz do 3,05 GHz -30 dBm do -20 dBm CMC 0,092 dB\nf = 500 MHz do 3,05 GHz -20 dBm do -10 dBm CMC 0,091 dB\nf = 500 MHz do 3,05 GHz -10 dBm do 0 dBm CMC 0,091 dB\nf = 500 MHz do 3,05 GHz 0 dBm do 20 dBm CMC 0,091 dB\nf = 500 MHz do 3,05 GHz 20 dBm do 35 dBm CMC 0,092 dB\nf = 500 MHz do 3,05 GHz 35 dBm do 44 dBm CMC 0,19 dB\nf = 3,05 GHz do 4 GHz -120 dBm do -110 dBm CMC 0,82 dB\nf = 3,05 GHz do 4 GHz -110 dBm do -100 dBm CMC 0,38 dB\nf = 3,05 GHz do 4 GHz -100 dBm do -90 dBm CMC 0,17 dB\nf = 3,05 GHz do 4 GHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 3,05 GHz do 4 GHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 3,05 GHz do 4 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 3,05 GHz do 4 GHz -60 dBm do -50 dBm CMC 0,11 dB\nf = 3,05 GHz do 4 GHz -50 dBm do -40 dBm CMC 0,095 dB\nf = 3,05 GHz do 4 GHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 3,05 GHz do 4 GHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 3,05 GHz do 4 GHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 3,05 GHz do 4 GHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 3,05 GHz do 4 GHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 3,05 GHz do 4 GHz 20 dBm do 35 dBm CMC 0,090 dB\nf = 3,05 GHz do 4 GHz 35 dBm do 40 dBm CMC 0,19 dB\nf = 4 GHz do 6,6 GHz -120 dBm do -110 dBm CMC 0,82 dB\nf = 4 GHz do 6,6 GHz -110 dBm do -100 dBm CMC 0,38 dB\nf = 4 GHz do 6,6 GHz -100 dBm do -90 dBm CMC 0,17 dB\nf = 4 GHz do 6,6 GHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 4 GHz do 6,6 GHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 4 GHz do 6,6 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 4 GHz do 6,6 GHz -60 dBm do -50 dBm CMC 0,11 dB\nf = 4 GHz do 6,6 GHz -50 dBm do -40 dBm CMC 0,095 dB\nf = 4 GHz do 6,6 GHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 4 GHz do 6,6 GHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 4 GHz do 6,6 GHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 4 GHz do 6,6 GHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 4 GHz do 6,6 GHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 6,6 GHz do 13,2 GHz -110 dBm do -100 dBm CMC 0,76 dB\nf = 6,6 GHz do 13,2 GHz -100 dBm do -90 dBm CMC 0,34 dB\nf = 6,6 GHz do 13,2 GHz -90 dBm do -80 dBm CMC 0,16 dB\nf = 6,6 GHz do 13,2 GHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 6,6 GHz do 13,2 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 6,6 GHz do 13,2 GHz -60 dBm do -50 dBm CMC 0,11 dB\nf = 6,6 GHz do 13,2 GHz -50 dBm do -40 dBm CMC 0,095 dB\nf = 6,6 GHz do 13,2 GHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 6,6 GHz do 13,2 GHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 6,6 GHz do 13,2 GHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 6,6 GHz do 13,2 GHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 6,6 GHz do 13,2 GHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 13,2 GHz do 18 GHz -100 dBm do -90 dBm CMC 0,65 dB\nf = 13,2 GHz do 18 GHz -90 dBm do -80 dBm CMC 0,28 dB\nf = 13,2 GHz do 18 GHz -80 dBm do -70 dBm CMC 0,15 dB\nf = 13,2 GHz do 18 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 13,2 GHz do 18 GHz -60 dBm do -50 dBm CMC 0,11 dB\nf = 13,2 GHz do 18 GHz -50 dBm do -40 dBm CMC 0,11 dB\nf = 13,2 GHz do 18 GHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 13,2 GHz do 18 GHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 13,2 GHz do 18 GHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 13,2 GHz do 18 GHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 13,2 GHz do 18 GHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 18 GHz do 19,2 GHz -100 dBm do -90 dBm CMC 0,65 dB\nf = 18 GHz do 19,2 GHz -90 dBm do -80 dBm CMC 0,29 dB\nf = 18 GHz do 19,2 GHz -80 dBm do -70 dBm CMC 0,16 dB\nf = 18 GHz do 19,2 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 18 GHz do 19,2 GHz -60 dBm do -50 dBm CMC 0,12 dB\nf = 18 GHz do 19,2 GHz -50 dBm do -40 dBm CMC 0,12 dB\nf = 18 GHz do 19,2 GHz -40 dBm do -30 dBm CMC 0,11 dB\nf = 18 GHz do 19,2 GHz -30 dBm do -20 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz -20 dBm do -10 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz -10 dBm do 0 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz 0 dBm do 20 dBm CMC 0,10 dB\nf = 19,2 GHz do 26,5 GHz -100 dBm do -90 dBm CMC 1,1 dB\nf = 19,2 GHz do 26,5 GHz -90 dBm do -80 dBm CMC 0,52 dB\nf = 19,2 GHz do 26,5 GHz -80 dBm do -70 dBm CMC 0,23 dB\nf = 19,2 GHz do 26,5 GHz -70 dBm do -60 dBm CMC 0,14 dB\nf = 19,2 GHz do 26,5 GHz -60 dBm do -50 dBm CMC 0,14 dB\nf = 19,2 GHz do 26,5 GHz -50 dBm do -40 dBm CMC 0,14 dB\nf = 19,2 GHz do 26,5 GHz -40 dBm do -30 dBm CMC 0,13 dB\nf = 19,2 GHz do 26,5 GHz -30 dBm do -20 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -20 dBm do -10 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -10 dBm do 0 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz 0 dBm do 20 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz -80 dBm do -70 dBm CMC 0,38 dB\nf = 26,5 GHz do 40 GHz -70 dBm do -60 dBm CMC 0,19 dB\nf = 26,5 GHz do 40 GHz -60 dBm do -50 dBm CMC 0,16 dB\nf = 26,5 GHz do 40 GHz -50 dBm do -40 dBm CMC 0,16 dB\nf = 26,5 GHz do 40 GHz -40 dBm do -30 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -30 dBm do -20 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -20 dBm do -10 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -10 dBm do 0 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz 0 dBm do 20 dBm CMC 0,14 dB\nf = 40 GHz do 50 GHz -40 dBm do -30 dBm CMC 0,20 dB\nf = 40 GHz do 50 GHz -30 dBm do -20 dBm CMC 0,20 dB\nf = 40 GHz do 50 GHz -20 dBm do -10 dBm CMC 0,17 dB\nf = 40 GHz do 50 GHz -10 dBm do 0 dBm CMC 0,16 dB\nf = 40 GHz do 50 GHz 0 dBm do 20 dBm CMC 0,16 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/48 Mierniki mocy\nCzujniki mocy\nAnalizatory obwodow\nAnalizatory widma\nAnalizatory systemow antenowych i kablowych\nAnalizatory modulacji analogowych\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\n- poziom mocy mierzonej Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\nf = 50 MHz -10 dBm do 10 dBm CMC 0,076 dB\nf = 10 Hz do 9 kHz -40 dBm do -30 dBm CMC 0,21 dB\nf = 10 Hz do 9 kHz -30 dBm do -20 dBm CMC 0,097 dB\nf = 10 Hz do 9 kHz -20 dBm do -10 dBm CMC 0,075 dB\nf = 10 Hz do 9 kHz -10 dBm do 0 dBm CMC 0,072 dB\nf = 10 Hz do 9 kHz 0 dBm do 20 dBm CMC 0,073 dB\nf = 9 kHz do 100 kHz -40 dBm do -30 dBm CMC 0,16 dB\nf = 9 kHz do 100 kHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 9 kHz do 100 kHz -20 dBm do -10 dBm CMC 0,081 dB\nf = 9 kHz do 100 kHz -10 dBm do 0 dBm CMC 0,075 dB\nf = 9 kHz do 100 kHz 0 dBm do 20 dBm CMC 0,087 dB\nf = 100 kHz do 10 MHz -130 dBm do -120 dBm CMC 1,20 dB\nf = 100 kHz do 10 MHz -120 dBm do -110 dBm CMC 0,57 dB\nf = 100 kHz do 10 MHz -110 dBm do -100 dBm CMC 0,24 dB\nf = 100 kHz do 10 MHz -100 dBm do -90 dBm CMC 0,13 dB\nf = 100 kHz do 10 MHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 100 kHz do 10 MHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 100 kHz do 10 MHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 100 kHz do 10 MHz -60 dBm do -50 dBm CMC 0,096 dB\nf = 100 kHz do 10 MHz -50 dBm do -40 dBm CMC 0,095 dB\nf = 100 kHz do 10 MHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 100 kHz do 10 MHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 100 kHz do 10 MHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 100 kHz do 10 MHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 100 kHz do 10 MHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 100 kHz do 10 MHz 20 dBm do 30 dBm CMC 0,092 dB\nf = 100 kHz do 10 MHz 30 dBm do 45 dBm CMC 0,19 dB\nf = 100 kHz do 10 MHz 45 dBm do 52 dBm CMC 0,22 dB\nf = 10 MHz do 500 MHz -130 dBm do -120 dBm CMC 0,94 dB\nf = 10 MHz do 500 MHz -120 dBm do -110 dBm CMC 0,45 dB\nf = 10 MHz do 500 MHz -110 dBm do -100 dBm CMC 0,19 dB\nf = 10 MHz do 500 MHz -100 dBm do -90 dBm CMC 0,13 dB\nf = 10 MHz do 500 MHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 10 MHz do 500 MHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 10 MHz do 500 MHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 10 MHz do 500 MHz -60 dBm do -50 dBm CMC 0,099 dB\nf = 10 MHz do 500 MHz -50 dBm do -40 dBm CMC 0,097 dB\nf = 10 MHz do 500 MHz -40 dBm do -30 dBm CMC 0,096 dB\nf = 10 MHz do 500 MHz -30 dBm do -20 dBm CMC 0,092 dB\nf = 10 MHz do 500 MHz -20 dBm do -10 dBm CMC 0,091 dB\nf = 10 MHz do 500 MHz -10 dBm do 0 dBm CMC 0,086 dB\nf = 10 MHz do 500 MHz 0 dBm do 20 dBm CMC 0,086 dB\nf = 10 MHz do 500 MHz 20 dBm do 35 dBm CMC 0,092 dB\nf = 10 MHz do 500 MHz 35 dBm do 45 dBm CMC 0,19 dB\nf = 10 MHz do 500 MHz 45 dBm do 52 dBm CMC 0,22 dB\nf = 500 MHz do 3,05 GHz -130 dBm do -120 dBm CMC 0,94 dB\nf = 500 MHz do 3,05 GHz -120 dBm do -110 dBm CMC 0,45 dB\nf = 500 MHz do 3,05 GHz -110 dBm do -100 dBm CMC 0,19 dB\nf = 500 MHz do 3,05 GHz -100 dBm do -90 dBm CMC 0,13 dB\nf = 500 MHz do 3,05 GHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 500 MHz do 3,05 GHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 500 MHz do 3,05 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 500 MHz do 3,05 GHz -60 dBm do -50 dBm CMC 0,099 dB\nf = 500 MHz do 3,05 GHz -50 dBm do -40 dBm CMC 0,097 dB\nf = 500 MHz do 3,05 GHz -40 dBm do -30 dBm CMC 0,096 dB\nf = 500 MHz do 3,05 GHz -30 dBm do -20 dBm CMC 0,092 dB\nf = 500 MHz do 3,05 GHz -20 dBm do -10 dBm CMC 0,091 dB\nf = 500 MHz do 3,05 GHz -10 dBm do 0 dBm CMC 0,091 dB\nf = 500 MHz do 3,05 GHz 0 dBm do 20 dBm CMC 0,091 dB\nf = 500 MHz do 3,05 GHz 20 dBm do 35 dBm CMC 0,092 dB\nf = 500 MHz do 3,05 GHz 35 dBm do 44 dBm CMC 0,19 dB\nf = 3,05 GHz do 4 GHz -120 dBm do -110 dBm CMC 0,82 dB\nf = 3,05 GHz do 4 GHz -110 dBm do -100 dBm CMC 0,38 dB\nf = 3,05 GHz do 4 GHz -100 dBm do -90 dBm CMC 0,17 dB\nf = 3,05 GHz do 4 GHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 3,05 GHz do 4 GHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 3,05 GHz do 4 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 3,05 GHz do 4 GHz -60 dBm do -50 dBm CMC 0,11 dB\nf = 3,05 GHz do 4 GHz -50 dBm do -40 dBm CMC 0,095 dB\nf = 3,05 GHz do 4 GHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 3,05 GHz do 4 GHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 3,05 GHz do 4 GHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 3,05 GHz do 4 GHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 3,05 GHz do 4 GHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 3,05 GHz do 4 GHz 20 dBm do 35 dBm CMC 0,090 dB\nf = 3,05 GHz do 4 GHz 35 dBm do 40 dBm CMC 0,19 dB\nf = 4 GHz do 6,6 GHz -120 dBm do -110 dBm CMC 0,82 dB\nf = 4 GHz do 6,6 GHz -110 dBm do -100 dBm CMC 0,38 dB\nf = 4 GHz do 6,6 GHz -100 dBm do -90 dBm CMC 0,17 dB\nf = 4 GHz do 6,6 GHz -90 dBm do -80 dBm CMC 0,12 dB\nf = 4 GHz do 6,6 GHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 4 GHz do 6,6 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 4 GHz do 6,6 GHz -60 dBm do -50 dBm CMC 0,11 dB\nf = 4 GHz do 6,6 GHz -50 dBm do -40 dBm CMC 0,095 dB\nf = 4 GHz do 6,6 GHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 4 GHz do 6,6 GHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 4 GHz do 6,6 GHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 4 GHz do 6,6 GHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 4 GHz do 6,6 GHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 6,6 GHz do 13,2 GHz -110 dBm do -100 dBm CMC 0,76 dB\nf = 6,6 GHz do 13,2 GHz -100 dBm do -90 dBm CMC 0,34 dB\nf = 6,6 GHz do 13,2 GHz -90 dBm do -80 dBm CMC 0,16 dB\nf = 6,6 GHz do 13,2 GHz -80 dBm do -70 dBm CMC 0,12 dB\nf = 6,6 GHz do 13,2 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 6,6 GHz do 13,2 GHz -60 dBm do -50 dBm CMC 0,11 dB\nf = 6,6 GHz do 13,2 GHz -50 dBm do -40 dBm CMC 0,095 dB\nf = 6,6 GHz do 13,2 GHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 6,6 GHz do 13,2 GHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 6,6 GHz do 13,2 GHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 6,6 GHz do 13,2 GHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 6,6 GHz do 13,2 GHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 13,2 GHz do 18 GHz -100 dBm do -90 dBm CMC 0,65 dB\nf = 13,2 GHz do 18 GHz -90 dBm do -80 dBm CMC 0,28 dB\nf = 13,2 GHz do 18 GHz -80 dBm do -70 dBm CMC 0,15 dB\nf = 13,2 GHz do 18 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 13,2 GHz do 18 GHz -60 dBm do -50 dBm CMC 0,11 dB\nf = 13,2 GHz do 18 GHz -50 dBm do -40 dBm CMC 0,11 dB\nf = 13,2 GHz do 18 GHz -40 dBm do -30 dBm CMC 0,093 dB\nf = 13,2 GHz do 18 GHz -30 dBm do -20 dBm CMC 0,090 dB\nf = 13,2 GHz do 18 GHz -20 dBm do -10 dBm CMC 0,088 dB\nf = 13,2 GHz do 18 GHz -10 dBm do 0 dBm CMC 0,088 dB\nf = 13,2 GHz do 18 GHz 0 dBm do 20 dBm CMC 0,088 dB\nf = 18 GHz do 19,2 GHz -100 dBm do -90 dBm CMC 0,65 dB\nf = 18 GHz do 19,2 GHz -90 dBm do -80 dBm CMC 0,29 dB\nf = 18 GHz do 19,2 GHz -80 dBm do -70 dBm CMC 0,16 dB\nf = 18 GHz do 19,2 GHz -70 dBm do -60 dBm CMC 0,12 dB\nf = 18 GHz do 19,2 GHz -60 dBm do -50 dBm CMC 0,12 dB\nf = 18 GHz do 19,2 GHz -50 dBm do -40 dBm CMC 0,12 dB\nf = 18 GHz do 19,2 GHz -40 dBm do -30 dBm CMC 0,11 dB\nf = 18 GHz do 19,2 GHz -30 dBm do -20 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz -20 dBm do -10 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz -10 dBm do 0 dBm CMC 0,10 dB\nf = 18 GHz do 19,2 GHz 0 dBm do 20 dBm CMC 0,10 dB\nf = 19,2 GHz do 26,5 GHz -100 dBm do -90 dBm CMC 1,1 dB\nf = 19,2 GHz do 26,5 GHz -90 dBm do -80 dBm CMC 0,52 dB\nf = 19,2 GHz do 26,5 GHz -80 dBm do -70 dBm CMC 0,23 dB\nf = 19,2 GHz do 26,5 GHz -70 dBm do -60 dBm CMC 0,14 dB\nf = 19,2 GHz do 26,5 GHz -60 dBm do -50 dBm CMC 0,14 dB\nf = 19,2 GHz do 26,5 GHz -50 dBm do -40 dBm CMC 0,14 dB\nf = 19,2 GHz do 26,5 GHz -40 dBm do -30 dBm CMC 0,13 dB\nf = 19,2 GHz do 26,5 GHz -30 dBm do -20 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -20 dBm do -10 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz -10 dBm do 0 dBm CMC 0,12 dB\nf = 19,2 GHz do 26,5 GHz 0 dBm do 20 dBm CMC 0,12 dB\nf = 26,5 GHz do 40 GHz -80 dBm do -70 dBm CMC 0,38 dB\nf = 26,5 GHz do 40 GHz -70 dBm do -60 dBm CMC 0,19 dB\nf = 26,5 GHz do 40 GHz -60 dBm do -50 dBm CMC 0,16 dB\nf = 26,5 GHz do 40 GHz -50 dBm do -40 dBm CMC 0,16 dB\nf = 26,5 GHz do 40 GHz -40 dBm do -30 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -30 dBm do -20 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -20 dBm do -10 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz -10 dBm do 0 dBm CMC 0,14 dB\nf = 26,5 GHz do 40 GHz 0 dBm do 20 dBm CMC 0,14 dB\nf = 40 GHz do 50 GHz -40 dBm do -30 dBm CMC 0,20 dB\nf = 40 GHz do 50 GHz -30 dBm do -20 dBm CMC 0,20 dB\nf = 40 GHz do 50 GHz -20 dBm do -10 dBm CMC 0,17 dB\nf = 40 GHz do 50 GHz -10 dBm do 0 dBm CMC 0,16 dB\nf = 40 GHz do 50 GHz 0 dBm do 20 dBm CMC 0,16 dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/48","search_en":"Power meters Power sensors Network analysers Spectrum analysers Antenna and cable system analysers Analogue modulation analysers Radio communication testers Measuring receivers - measured power level Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 MHz f = 10 Hz to 9 kHz f = 10 Hz to 9 kHz f = 10 Hz to 9 kHz f = 10 Hz to 9 kHz f = 10 Hz to 9 kHz f = 9 kHz to 100 kHz f = 9 kHz to 100 kHz f = 9 kHz to 100 kHz f = 9 kHz to 100 kHz f = 9 kHz to 100 kHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 10 MHz to 500 MHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 500 MHz to 3,05 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 3,05 GHz to 4 GHz f = 4 GHz to 6,6 GHz f = 4 GHz to 6,6 GHz f = 4 GHz to 6,6 GHz f = 4 GHz to 6,6 GHz f = 4 GHz to 6,6 GHz f = 4 GHz to 6,6 GHz f = 4 GHz to 6,6 GHz f = 4 GHz to 6,6 GHz f = 4 GHz to 6,6 GHz f = 4 GHz to 6,6 GHz f = 4 GHz to 6,6 GHz f = 4 GHz to 6,6 GHz f = 4 GHz to 6,6 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 13,2 GHz to 18 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 18 GHz to 19,2 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 40 GHz to 50 GHz f = 40 GHz to 50 GHz f = 40 GHz to 50 GHz f = 40 GHz to 50 GHz f = 40 GHz to 50 GHz LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/48","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":43,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"f = 50 MHz","range":"-10 dBm to 10 dBm","cmc":"0,076 dB"},{"name":"f = 10 Hz bis 9 kHz","range":"-40 dBm to -30 dBm","cmc":"0,21 dB"},{"name":"f = 10 Hz bis 9 kHz","range":"-30 dBm to -20 dBm","cmc":"0,097 dB"},{"name":"f = 10 Hz bis 9 kHz","range":"-20 dBm to -10 dBm","cmc":"0,075 dB"},{"name":"f = 10 Hz bis 9 kHz","range":"-10 dBm to 0 dBm","cmc":"0,072 dB"},{"name":"f = 10 Hz bis 9 kHz","range":"0 dBm to 20 dBm","cmc":"0,073 dB"},{"name":"f = 9 kHz bis 100 kHz","range":"-40 dBm to -30 dBm","cmc":"0,16 dB"},{"name":"f = 9 kHz bis 100 kHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 9 kHz bis 100 kHz","range":"-20 dBm to -10 dBm","cmc":"0,081 dB"},{"name":"f = 9 kHz bis 100 kHz","range":"-10 dBm to 0 dBm","cmc":"0,075 dB"},{"name":"f = 9 kHz bis 100 kHz","range":"0 dBm to 20 dBm","cmc":"0,087 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-130 dBm to -120 dBm","cmc":"1,20 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-120 dBm to -110 dBm","cmc":"0,57 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-110 dBm to -100 dBm","cmc":"0,24 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-100 dBm to -90 dBm","cmc":"0,13 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-60 dBm to -50 dBm","cmc":"0,096 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"20 dBm to 30 dBm","cmc":"0,092 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"30 dBm to 45 dBm","cmc":"0,19 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"45 dBm to 52 dBm","cmc":"0,22 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-130 dBm to -120 dBm","cmc":"0,94 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-120 dBm to -110 dBm","cmc":"0,45 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-110 dBm to -100 dBm","cmc":"0,19 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-100 dBm to -90 dBm","cmc":"0,13 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-60 dBm to -50 dBm","cmc":"0,099 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-50 dBm to -40 dBm","cmc":"0,097 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-40 dBm to -30 dBm","cmc":"0,096 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-30 dBm to -20 dBm","cmc":"0,092 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-20 dBm to -10 dBm","cmc":"0,091 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"-10 dBm to 0 dBm","cmc":"0,086 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"0 dBm to 20 dBm","cmc":"0,086 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"20 dBm to 35 dBm","cmc":"0,092 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"35 dBm to 45 dBm","cmc":"0,19 dB"},{"name":"f = 10 MHz bis 500 MHz","range":"45 dBm to 52 dBm","cmc":"0,22 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-130 dBm to -120 dBm","cmc":"0,94 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-120 dBm to -110 dBm","cmc":"0,45 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-110 dBm to -100 dBm","cmc":"0,19 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-100 dBm to -90 dBm","cmc":"0,13 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-60 dBm to -50 dBm","cmc":"0,099 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-50 dBm to -40 dBm","cmc":"0,097 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-40 dBm to -30 dBm","cmc":"0,096 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-30 dBm to -20 dBm","cmc":"0,092 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-20 dBm to -10 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"-10 dBm to 0 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"0 dBm to 20 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"20 dBm to 35 dBm","cmc":"0,092 dB"},{"name":"f = 500 MHz bis 3,05 GHz","range":"35 dBm to 44 dBm","cmc":"0,19 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"-120 dBm to -110 dBm","cmc":"0,82 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"-110 dBm to -100 dBm","cmc":"0,38 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"-100 dBm to -90 dBm","cmc":"0,17 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"20 dBm to 35 dBm","cmc":"0,090 dB"},{"name":"f = 3,05 GHz bis 4 GHz","range":"35 dBm to 40 dBm","cmc":"0,19 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"-120 dBm to -110 dBm","cmc":"0,82 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"-110 dBm to -100 dBm","cmc":"0,38 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"-100 dBm to -90 dBm","cmc":"0,17 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 4 GHz bis 6,6 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-110 dBm to -100 dBm","cmc":"0,76 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,34 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,16 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-90 dBm to -80 dBm","cmc":"0,28 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-80 dBm to -70 dBm","cmc":"0,15 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-50 dBm to -40 dBm","cmc":"0,11 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz bis 18 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,29 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,16 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,11 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz bis 19,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,10 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-100 dBm to -90 dBm","cmc":"1,1 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-90 dBm to -80 dBm","cmc":"0,52 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-80 dBm to -70 dBm","cmc":"0,23 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-70 dBm to -60 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-60 dBm to -50 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-50 dBm to -40 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-40 dBm to -30 dBm","cmc":"0,13 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-30 dBm to -20 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-20 dBm to -10 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-10 dBm to 0 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"0 dBm to 20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-80 dBm to -70 dBm","cmc":"0,38 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-70 dBm to -60 dBm","cmc":"0,19 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-60 dBm to -50 dBm","cmc":"0,16 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-50 dBm to -40 dBm","cmc":"0,16 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-30 dBm to -20 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-20 dBm to -10 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-10 dBm to 0 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"0 dBm to 20 dBm","cmc":"0,14 dB"},{"name":"f = 40 GHz bis 50 GHz","range":"-40 dBm to -30 dBm","cmc":"0,20 dB"},{"name":"f = 40 GHz bis 50 GHz","range":"-30 dBm to -20 dBm","cmc":"0,20 dB"},{"name":"f = 40 GHz bis 50 GHz","range":"-20 dBm to -10 dBm","cmc":"0,17 dB"},{"name":"f = 40 GHz bis 50 GHz","range":"-10 dBm to 0 dBm","cmc":"0,16 dB"},{"name":"f = 40 GHz bis 50 GHz","range":"0 dBm to 20 dBm","cmc":"0,16 dB"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Leistungsmesser Leistungssensoren Netzwerkanalysatoren Spektrumanalysatoren Analysatoren für Antennen- und Kabelsysteme Analysatoren für analoge Modulation Funkkommunikationstester Messempfänger - gemessener Leistungspegel Kalibrierung — elektrische HF-Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 MHz f = 10 Hz bis 9 kHz f = 10 Hz bis 9 kHz f = 10 Hz bis 9 kHz f = 10 Hz bis 9 kHz f = 10 Hz bis 9 kHz f = 9 kHz bis 100 kHz f = 9 kHz bis 100 kHz f = 9 kHz bis 100 kHz f = 9 kHz bis 100 kHz f = 9 kHz bis 100 kHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 10 MHz bis 500 MHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 500 MHz bis 3,05 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 3,05 GHz bis 4 GHz f = 4 GHz bis 6,6 GHz f = 4 GHz bis 6,6 GHz f = 4 GHz bis 6,6 GHz f = 4 GHz bis 6,6 GHz f = 4 GHz bis 6,6 GHz f = 4 GHz bis 6,6 GHz f = 4 GHz bis 6,6 GHz f = 4 GHz bis 6,6 GHz f = 4 GHz bis 6,6 GHz f = 4 GHz bis 6,6 GHz f = 4 GHz bis 6,6 GHz f = 4 GHz bis 6,6 GHz f = 4 GHz bis 6,6 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 13,2 GHz bis 18 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 18 GHz bis 19,2 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 40 GHz bis 50 GHz f = 40 GHz bis 50 GHz f = 40 GHz bis 50 GHz f = 40 GHz bis 50 GHz f = 40 GHz bis 50 GHz LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/48","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Leistungsmesser\nLeistungssensoren\nNetzwerkanalysatoren\nSpektrumanalysatoren\nAnalysatoren für Antennen- und Kabelsysteme\nAnalysatoren für analoge Modulation\nFunkkommunikationstester\nMessempfänger\n- gemessener Leistungspegel","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"f = 50 MHz","range":"-10 dBm to 10 dBm","cmc":"0,076 dB"},{"name":"f = 10 Hz 至 9 kHz","range":"-40 dBm to -30 dBm","cmc":"0,21 dB"},{"name":"f = 10 Hz 至 9 kHz","range":"-30 dBm to -20 dBm","cmc":"0,097 dB"},{"name":"f = 10 Hz 至 9 kHz","range":"-20 dBm to -10 dBm","cmc":"0,075 dB"},{"name":"f = 10 Hz 至 9 kHz","range":"-10 dBm to 0 dBm","cmc":"0,072 dB"},{"name":"f = 10 Hz 至 9 kHz","range":"0 dBm to 20 dBm","cmc":"0,073 dB"},{"name":"f = 9 kHz 至 100 kHz","range":"-40 dBm to -30 dBm","cmc":"0,16 dB"},{"name":"f = 9 kHz 至 100 kHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 9 kHz 至 100 kHz","range":"-20 dBm to -10 dBm","cmc":"0,081 dB"},{"name":"f = 9 kHz 至 100 kHz","range":"-10 dBm to 0 dBm","cmc":"0,075 dB"},{"name":"f = 9 kHz 至 100 kHz","range":"0 dBm to 20 dBm","cmc":"0,087 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-130 dBm to -120 dBm","cmc":"1,20 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-120 dBm to -110 dBm","cmc":"0,57 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-110 dBm to -100 dBm","cmc":"0,24 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-100 dBm to -90 dBm","cmc":"0,13 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-60 dBm to -50 dBm","cmc":"0,096 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"20 dBm to 30 dBm","cmc":"0,092 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"30 dBm to 45 dBm","cmc":"0,19 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"45 dBm to 52 dBm","cmc":"0,22 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-130 dBm to -120 dBm","cmc":"0,94 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-120 dBm to -110 dBm","cmc":"0,45 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-110 dBm to -100 dBm","cmc":"0,19 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-100 dBm to -90 dBm","cmc":"0,13 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-60 dBm to -50 dBm","cmc":"0,099 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-50 dBm to -40 dBm","cmc":"0,097 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-40 dBm to -30 dBm","cmc":"0,096 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-30 dBm to -20 dBm","cmc":"0,092 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-20 dBm to -10 dBm","cmc":"0,091 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"-10 dBm to 0 dBm","cmc":"0,086 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"0 dBm to 20 dBm","cmc":"0,086 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"20 dBm to 35 dBm","cmc":"0,092 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"35 dBm to 45 dBm","cmc":"0,19 dB"},{"name":"f = 10 MHz 至 500 MHz","range":"45 dBm to 52 dBm","cmc":"0,22 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-130 dBm to -120 dBm","cmc":"0,94 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-120 dBm to -110 dBm","cmc":"0,45 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-110 dBm to -100 dBm","cmc":"0,19 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-100 dBm to -90 dBm","cmc":"0,13 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-60 dBm to -50 dBm","cmc":"0,099 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-50 dBm to -40 dBm","cmc":"0,097 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-40 dBm to -30 dBm","cmc":"0,096 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-30 dBm to -20 dBm","cmc":"0,092 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-20 dBm to -10 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"-10 dBm to 0 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"0 dBm to 20 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"20 dBm to 35 dBm","cmc":"0,092 dB"},{"name":"f = 500 MHz 至 3,05 GHz","range":"35 dBm to 44 dBm","cmc":"0,19 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"-120 dBm to -110 dBm","cmc":"0,82 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"-110 dBm to -100 dBm","cmc":"0,38 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"-100 dBm to -90 dBm","cmc":"0,17 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"20 dBm to 35 dBm","cmc":"0,090 dB"},{"name":"f = 3,05 GHz 至 4 GHz","range":"35 dBm to 40 dBm","cmc":"0,19 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"-120 dBm to -110 dBm","cmc":"0,82 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"-110 dBm to -100 dBm","cmc":"0,38 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"-100 dBm to -90 dBm","cmc":"0,17 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 4 GHz 至 6,6 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-110 dBm to -100 dBm","cmc":"0,76 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,34 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,16 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-90 dBm to -80 dBm","cmc":"0,28 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-80 dBm to -70 dBm","cmc":"0,15 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-50 dBm to -40 dBm","cmc":"0,11 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz 至 18 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,29 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,16 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,11 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz 至 19,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,10 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-100 dBm to -90 dBm","cmc":"1,1 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-90 dBm to -80 dBm","cmc":"0,52 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-80 dBm to -70 dBm","cmc":"0,23 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-70 dBm to -60 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-60 dBm to -50 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-50 dBm to -40 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-40 dBm to -30 dBm","cmc":"0,13 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-30 dBm to -20 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-20 dBm to -10 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-10 dBm to 0 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"0 dBm to 20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-80 dBm to -70 dBm","cmc":"0,38 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-70 dBm to -60 dBm","cmc":"0,19 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-60 dBm to -50 dBm","cmc":"0,16 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-50 dBm to -40 dBm","cmc":"0,16 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-30 dBm to -20 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-20 dBm to -10 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-10 dBm to 0 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"0 dBm to 20 dBm","cmc":"0,14 dB"},{"name":"f = 40 GHz 至 50 GHz","range":"-40 dBm to -30 dBm","cmc":"0,20 dB"},{"name":"f = 40 GHz 至 50 GHz","range":"-30 dBm to -20 dBm","cmc":"0,20 dB"},{"name":"f = 40 GHz 至 50 GHz","range":"-20 dBm to -10 dBm","cmc":"0,17 dB"},{"name":"f = 40 GHz 至 50 GHz","range":"-10 dBm to 0 dBm","cmc":"0,16 dB"},{"name":"f = 40 GHz 至 50 GHz","range":"0 dBm to 20 dBm","cmc":"0,16 dB"}],"regulatory_area_zh":"射频电学量","search_zh":"功率计 功率传感器 网络分析仪 频谱分析仪 天线与电缆系统分析仪 模拟调制分析仪 无线电通信测试仪 测量接收机 - 测量功率电平 校准 — 射频电学量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 MHz f = 10 Hz 至 9 kHz f = 10 Hz 至 9 kHz f = 10 Hz 至 9 kHz f = 10 Hz 至 9 kHz f = 10 Hz 至 9 kHz f = 9 kHz 至 100 kHz f = 9 kHz 至 100 kHz f = 9 kHz 至 100 kHz f = 9 kHz 至 100 kHz f = 9 kHz 至 100 kHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 10 MHz 至 500 MHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 500 MHz 至 3,05 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 3,05 GHz 至 4 GHz f = 4 GHz 至 6,6 GHz f = 4 GHz 至 6,6 GHz f = 4 GHz 至 6,6 GHz f = 4 GHz 至 6,6 GHz f = 4 GHz 至 6,6 GHz f = 4 GHz 至 6,6 GHz f = 4 GHz 至 6,6 GHz f = 4 GHz 至 6,6 GHz f = 4 GHz 至 6,6 GHz f = 4 GHz 至 6,6 GHz f = 4 GHz 至 6,6 GHz f = 4 GHz 至 6,6 GHz f = 4 GHz 至 6,6 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 13,2 GHz 至 18 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 18 GHz 至 19,2 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 40 GHz 至 50 GHz f = 40 GHz 至 50 GHz f = 40 GHz 至 50 GHz f = 40 GHz 至 50 GHz f = 40 GHz 至 50 GHz LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/48","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"功率计\n功率传感器\n网络分析仪\n频谱分析仪\n天线与电缆系统分析仪\n模拟调制分析仪\n无线电通信测试仪\n测量接收机\n- 测量功率电平","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"f = 50 MHz","range":"-10 dBm to 10 dBm","cmc":"0,076 dB"},{"name":"f = 10 Hz až 9 kHz","range":"-40 dBm to -30 dBm","cmc":"0,21 dB"},{"name":"f = 10 Hz až 9 kHz","range":"-30 dBm to -20 dBm","cmc":"0,097 dB"},{"name":"f = 10 Hz až 9 kHz","range":"-20 dBm to -10 dBm","cmc":"0,075 dB"},{"name":"f = 10 Hz až 9 kHz","range":"-10 dBm to 0 dBm","cmc":"0,072 dB"},{"name":"f = 10 Hz až 9 kHz","range":"0 dBm to 20 dBm","cmc":"0,073 dB"},{"name":"f = 9 kHz až 100 kHz","range":"-40 dBm to -30 dBm","cmc":"0,16 dB"},{"name":"f = 9 kHz až 100 kHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 9 kHz až 100 kHz","range":"-20 dBm to -10 dBm","cmc":"0,081 dB"},{"name":"f = 9 kHz až 100 kHz","range":"-10 dBm to 0 dBm","cmc":"0,075 dB"},{"name":"f = 9 kHz až 100 kHz","range":"0 dBm to 20 dBm","cmc":"0,087 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-130 dBm to -120 dBm","cmc":"1,20 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-120 dBm to -110 dBm","cmc":"0,57 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-110 dBm to -100 dBm","cmc":"0,24 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-100 dBm to -90 dBm","cmc":"0,13 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-60 dBm to -50 dBm","cmc":"0,096 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz až 10 MHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 100 kHz až 10 MHz","range":"20 dBm to 30 dBm","cmc":"0,092 dB"},{"name":"f = 100 kHz až 10 MHz","range":"30 dBm to 45 dBm","cmc":"0,19 dB"},{"name":"f = 100 kHz až 10 MHz","range":"45 dBm to 52 dBm","cmc":"0,22 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-130 dBm to -120 dBm","cmc":"0,94 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-120 dBm to -110 dBm","cmc":"0,45 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-110 dBm to -100 dBm","cmc":"0,19 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-100 dBm to -90 dBm","cmc":"0,13 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-60 dBm to -50 dBm","cmc":"0,099 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-50 dBm to -40 dBm","cmc":"0,097 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-40 dBm to -30 dBm","cmc":"0,096 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-30 dBm to -20 dBm","cmc":"0,092 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-20 dBm to -10 dBm","cmc":"0,091 dB"},{"name":"f = 10 MHz až 500 MHz","range":"-10 dBm to 0 dBm","cmc":"0,086 dB"},{"name":"f = 10 MHz až 500 MHz","range":"0 dBm to 20 dBm","cmc":"0,086 dB"},{"name":"f = 10 MHz až 500 MHz","range":"20 dBm to 35 dBm","cmc":"0,092 dB"},{"name":"f = 10 MHz až 500 MHz","range":"35 dBm to 45 dBm","cmc":"0,19 dB"},{"name":"f = 10 MHz až 500 MHz","range":"45 dBm to 52 dBm","cmc":"0,22 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-130 dBm to -120 dBm","cmc":"0,94 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-120 dBm to -110 dBm","cmc":"0,45 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-110 dBm to -100 dBm","cmc":"0,19 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-100 dBm to -90 dBm","cmc":"0,13 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-60 dBm to -50 dBm","cmc":"0,099 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-50 dBm to -40 dBm","cmc":"0,097 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-40 dBm to -30 dBm","cmc":"0,096 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-30 dBm to -20 dBm","cmc":"0,092 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-20 dBm to -10 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"-10 dBm to 0 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"0 dBm to 20 dBm","cmc":"0,091 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"20 dBm to 35 dBm","cmc":"0,092 dB"},{"name":"f = 500 MHz až 3,05 GHz","range":"35 dBm to 44 dBm","cmc":"0,19 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"-120 dBm to -110 dBm","cmc":"0,82 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"-110 dBm to -100 dBm","cmc":"0,38 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"-100 dBm to -90 dBm","cmc":"0,17 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"20 dBm to 35 dBm","cmc":"0,090 dB"},{"name":"f = 3,05 GHz až 4 GHz","range":"35 dBm to 40 dBm","cmc":"0,19 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"-120 dBm to -110 dBm","cmc":"0,82 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"-110 dBm to -100 dBm","cmc":"0,38 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"-100 dBm to -90 dBm","cmc":"0,17 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"-90 dBm to -80 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 4 GHz až 6,6 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-110 dBm to -100 dBm","cmc":"0,76 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,34 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,16 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,12 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,095 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-90 dBm to -80 dBm","cmc":"0,28 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-80 dBm to -70 dBm","cmc":"0,15 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-60 dBm to -50 dBm","cmc":"0,11 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-50 dBm to -40 dBm","cmc":"0,11 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-40 dBm to -30 dBm","cmc":"0,093 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-30 dBm to -20 dBm","cmc":"0,090 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-20 dBm to -10 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"-10 dBm to 0 dBm","cmc":"0,088 dB"},{"name":"f = 13,2 GHz až 18 GHz","range":"0 dBm to 20 dBm","cmc":"0,088 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-100 dBm to -90 dBm","cmc":"0,65 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-90 dBm to -80 dBm","cmc":"0,29 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-80 dBm to -70 dBm","cmc":"0,16 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-70 dBm to -60 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-60 dBm to -50 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-50 dBm to -40 dBm","cmc":"0,12 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-40 dBm to -30 dBm","cmc":"0,11 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-30 dBm to -20 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-20 dBm to -10 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"-10 dBm to 0 dBm","cmc":"0,10 dB"},{"name":"f = 18 GHz až 19,2 GHz","range":"0 dBm to 20 dBm","cmc":"0,10 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-100 dBm to -90 dBm","cmc":"1,1 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-90 dBm to -80 dBm","cmc":"0,52 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-80 dBm to -70 dBm","cmc":"0,23 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-70 dBm to -60 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-60 dBm to -50 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-50 dBm to -40 dBm","cmc":"0,14 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-40 dBm to -30 dBm","cmc":"0,13 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-30 dBm to -20 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-20 dBm to -10 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-10 dBm to 0 dBm","cmc":"0,12 dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"0 dBm to 20 dBm","cmc":"0,12 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-80 dBm to -70 dBm","cmc":"0,38 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-70 dBm to -60 dBm","cmc":"0,19 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-60 dBm to -50 dBm","cmc":"0,16 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-50 dBm to -40 dBm","cmc":"0,16 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-40 dBm to -30 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-30 dBm to -20 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-20 dBm to -10 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-10 dBm to 0 dBm","cmc":"0,14 dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"0 dBm to 20 dBm","cmc":"0,14 dB"},{"name":"f = 40 GHz až 50 GHz","range":"-40 dBm to -30 dBm","cmc":"0,20 dB"},{"name":"f = 40 GHz až 50 GHz","range":"-30 dBm to -20 dBm","cmc":"0,20 dB"},{"name":"f = 40 GHz až 50 GHz","range":"-20 dBm to -10 dBm","cmc":"0,17 dB"},{"name":"f = 40 GHz až 50 GHz","range":"-10 dBm to 0 dBm","cmc":"0,16 dB"},{"name":"f = 40 GHz až 50 GHz","range":"0 dBm to 20 dBm","cmc":"0,16 dB"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Měřiče výkonu Čidla výkonu Obvodové analyzátory Spektrální analyzátory Analyzátory anténních a kabelových systémů Analyzátory analogové modulace Radiokomunikační testery Měřicí přijímače - úroveň měřeného výkonu Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 MHz f = 10 Hz až 9 kHz f = 10 Hz až 9 kHz f = 10 Hz až 9 kHz f = 10 Hz až 9 kHz f = 10 Hz až 9 kHz f = 9 kHz až 100 kHz f = 9 kHz až 100 kHz f = 9 kHz až 100 kHz f = 9 kHz až 100 kHz f = 9 kHz až 100 kHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 10 MHz až 500 MHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 500 MHz až 3,05 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 3,05 GHz až 4 GHz f = 4 GHz až 6,6 GHz f = 4 GHz až 6,6 GHz f = 4 GHz až 6,6 GHz f = 4 GHz až 6,6 GHz f = 4 GHz až 6,6 GHz f = 4 GHz až 6,6 GHz f = 4 GHz až 6,6 GHz f = 4 GHz až 6,6 GHz f = 4 GHz až 6,6 GHz f = 4 GHz až 6,6 GHz f = 4 GHz až 6,6 GHz f = 4 GHz až 6,6 GHz f = 4 GHz až 6,6 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 13,2 GHz až 18 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 18 GHz až 19,2 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 40 GHz až 50 GHz f = 40 GHz až 50 GHz f = 40 GHz až 50 GHz f = 40 GHz až 50 GHz f = 40 GHz až 50 GHz LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/48","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče výkonu\nČidla výkonu\nObvodové analyzátory\nSpektrální analyzátory\nAnalyzátory anténních a kabelových systémů\nAnalyzátory analogové modulace\nRadiokomunikační testery\nMěřicí přijímače\n- úroveň měřeného výkonu"},{"_id":"fe0638b3596aa9ecf91d1081","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Tłumiki\nSprzęgacze\nWzmacniacze\n- transmisja skalarna\nGeneratory\nAnalizatory obwodów\nTestery radiokomunikacyjne\n- względny poziom mocy wyjściowej\nAnalizatory obwodów\nAnalizatory widma\nAnalizatory systemów antenowych i kablowych\nOdbiorniki pomiarowe\nTestery radiokomunikacyjne\n- względny poziom mocy mierzonej","test_object_en":"Attenuators\nCouplers\nAmplifiers\n- scalar transmission\nGenerators\nNetwork analysers\nRadio communication testers\n- relative output power level\nNetwork analysers\nSpectrum analysers\nAntenna and cable system analysers\nMeasuring receivers\nRadio communication testers\n- relative measured power level","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"f = 9 kHz do 100 kHz","range":"-60 dB od -50 dB","cmc":"0,095 dB"},{"name":"f = 9 kHz do 100 kHz","range":"-50 dB od -30 dB","cmc":"0,023 dB"},{"name":"f = 9 kHz do 100 kHz","range":"30 dB od 20 dB","cmc":"0,016 dB"},{"name":"f = 100 kHz do 10 MHz","range":"-131 dB do -101 dB","cmc":"0,13 dB + δ"},{"name":"f = 100 kHz do 10 MHz","range":"-101 dB do -60 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 100 kHz do 10 MHz","range":"-60 dB do 50 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-134 dB do -104 dB","cmc":"0,13 dB + δ"},{"name":"f = 10 MHz do 3,05 GHz","range":"-104 dB do -61 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 10 MHz do 3,05 GHz","range":"-61 dB do 50 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-126 dB do -96 dB","cmc":"0,13 dB + δ"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-96 dB do -57dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 3,05 GHz do 6,6 GHz","range":"-57dB do 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-117 dB do -87 dB","cmc":"0,12 dB + δ"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-87 dB do -52 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 6,6 GHz do 13,2 GHz","range":"-52 dB do 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 13,2 GHz do 19,2 GHz","range":"-109 dB do -79 dB","cmc":"0,12 dB + δ"},{"name":"f = 13,2 GHz do 19,2 GHz","range":"-79 dB do -44 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 13,2 GHz do 19,2 GHz","range":"-44 dB do 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-102 dB do -72 dB","cmc":"0,12 dB + δ"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-72 dB do -34 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 19,2 GHz do 26,5 GHz","range":"-34 dB do 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-96 dB do -66 dB","cmc":"0,12 dB + δ"},{"name":"f = 26,5 GHz do 40 GHz","range":"-66 dB do -51 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 26,5 GHz do 40 GHz","range":"-51 dB do 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"}],"parameters_en":[{"name":"f = 9 kHz to 100 kHz","range":"-60 dB from -50 dB","cmc":"0,095 dB"},{"name":"f = 9 kHz to 100 kHz","range":"-50 dB from -30 dB","cmc":"0,023 dB"},{"name":"f = 9 kHz to 100 kHz","range":"30 dB from 20 dB","cmc":"0,016 dB"},{"name":"f = 100 kHz to 10 MHz","range":"-131 dB to -101 dB","cmc":"0,13 dB + δ"},{"name":"f = 100 kHz to 10 MHz","range":"-101 dB to -60 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 100 kHz to 10 MHz","range":"-60 dB to 50 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-134 dB to -104 dB","cmc":"0,13 dB + δ"},{"name":"f = 10 MHz to 3,05 GHz","range":"-104 dB to -61 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 10 MHz to 3,05 GHz","range":"-61 dB to 50 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-126 dB to -96 dB","cmc":"0,13 dB + δ"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-96 dB to -57dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 3,05 GHz to 6,6 GHz","range":"-57dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-117 dB to -87 dB","cmc":"0,12 dB + δ"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-87 dB to -52 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 6,6 GHz to 13,2 GHz","range":"-52 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 13,2 GHz to 19,2 GHz","range":"-109 dB to -79 dB","cmc":"0,12 dB + δ"},{"name":"f = 13,2 GHz to 19,2 GHz","range":"-79 dB to -44 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 13,2 GHz to 19,2 GHz","range":"-44 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-102 dB to -72 dB","cmc":"0,12 dB + δ"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-72 dB to -34 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 19,2 GHz to 26,5 GHz","range":"-34 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-96 dB to -66 dB","cmc":"0,12 dB + δ"},{"name":"f = 26,5 GHz to 40 GHz","range":"-66 dB to -51 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 26,5 GHz to 40 GHz","range":"-51 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 9 kHz do 100 kHz -60 dB od -50 dB CMC 0,095 dB\nf = 9 kHz do 100 kHz -50 dB od -30 dB CMC 0,023 dB\nf = 9 kHz do 100 kHz 30 dB od 20 dB CMC 0,016 dB\nf = 100 kHz do 10 MHz -131 dB do -101 dB CMC 0,13 dB + δ\nf = 100 kHz do 10 MHz -101 dB do -60 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 100 kHz do 10 MHz -60 dB do 50 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 10 MHz do 3,05 GHz -134 dB do -104 dB CMC 0,13 dB + δ\nf = 10 MHz do 3,05 GHz -104 dB do -61 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 10 MHz do 3,05 GHz -61 dB do 50 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 3,05 GHz do 6,6 GHz -126 dB do -96 dB CMC 0,13 dB + δ\nf = 3,05 GHz do 6,6 GHz -96 dB do -57dB CMC (0,040 + 0,0005 - |P|) dB\nf = 3,05 GHz do 6,6 GHz -57dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 6,6 GHz do 13,2 GHz -117 dB do -87 dB CMC 0,12 dB + δ\nf = 6,6 GHz do 13,2 GHz -87 dB do -52 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 6,6 GHz do 13,2 GHz -52 dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 13,2 GHz do 19,2 GHz -109 dB do -79 dB CMC 0,12 dB + δ\nf = 13,2 GHz do 19,2 GHz -79 dB do -44 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 13,2 GHz do 19,2 GHz -44 dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 19,2 GHz do 26,5 GHz -102 dB do -72 dB CMC 0,12 dB + δ\nf = 19,2 GHz do 26,5 GHz -72 dB do -34 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 19,2 GHz do 26,5 GHz -34 dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 26,5 GHz do 40 GHz -96 dB do -66 dB CMC 0,12 dB + δ\nf = 26,5 GHz do 40 GHz -66 dB do -51 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 26,5 GHz do 40 GHz -51 dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/32\nLMEEiO/33\nLMEEiO/34\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/44\nLMEEiO/48","norm_bases":["LMEEiO/32","LMEEiO/33","LMEEiO/34","LMEEiO/39","LMEEiO/40","LMEEiO/41","LMEEiO/44","LMEEiO/48"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":"P [dBm] – wartość wielkości zmierzona; δ=0,0012·(P – N)²; N = Pₘᵢₙ + 30 dB; Pₘᵢₙ [dBm] – wartość minimalna zakresu pomiarowego","note_en":"P [dBm] – measured value of the quantity; δ=0,0012·(P – N)²; N = Pₘᵢₙ + 30 dB; Pₘᵢₙ [dBm] – minimum value of the measuring range","search_text":"Tłumiki\nSprzęgacze\nWzmacniacze\n- transmisja skalarna\nGeneratory\nAnalizatory obwodów\nTestery radiokomunikacyjne\n- względny poziom mocy wyjściowej\nAnalizatory obwodów\nAnalizatory widma\nAnalizatory systemów antenowych i kablowych\nOdbiorniki pomiarowe\nTestery radiokomunikacyjne\n- względny poziom mocy mierzonej Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 9 kHz do 100 kHz -60 dB od -50 dB CMC 0,095 dB\nf = 9 kHz do 100 kHz -50 dB od -30 dB CMC 0,023 dB\nf = 9 kHz do 100 kHz 30 dB od 20 dB CMC 0,016 dB\nf = 100 kHz do 10 MHz -131 dB do -101 dB CMC 0,13 dB + δ\nf = 100 kHz do 10 MHz -101 dB do -60 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 100 kHz do 10 MHz -60 dB do 50 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 10 MHz do 3,05 GHz -134 dB do -104 dB CMC 0,13 dB + δ\nf = 10 MHz do 3,05 GHz -104 dB do -61 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 10 MHz do 3,05 GHz -61 dB do 50 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 3,05 GHz do 6,6 GHz -126 dB do -96 dB CMC 0,13 dB + δ\nf = 3,05 GHz do 6,6 GHz -96 dB do -57dB CMC (0,040 + 0,0005 - |P|) dB\nf = 3,05 GHz do 6,6 GHz -57dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 6,6 GHz do 13,2 GHz -117 dB do -87 dB CMC 0,12 dB + δ\nf = 6,6 GHz do 13,2 GHz -87 dB do -52 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 6,6 GHz do 13,2 GHz -52 dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 13,2 GHz do 19,2 GHz -109 dB do -79 dB CMC 0,12 dB + δ\nf = 13,2 GHz do 19,2 GHz -79 dB do -44 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 13,2 GHz do 19,2 GHz -44 dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 19,2 GHz do 26,5 GHz -102 dB do -72 dB CMC 0,12 dB + δ\nf = 19,2 GHz do 26,5 GHz -72 dB do -34 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 19,2 GHz do 26,5 GHz -34 dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 26,5 GHz do 40 GHz -96 dB do -66 dB CMC 0,12 dB + δ\nf = 26,5 GHz do 40 GHz -66 dB do -51 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 26,5 GHz do 40 GHz -51 dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/32\nLMEEiO/33\nLMEEiO/34\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/44\nLMEEiO/48 Tlumiki\nSprzegacze\nWzmacniacze\n- transmisja skalarna\nGeneratory\nAnalizatory obwodow\nTestery radiokomunikacyjne\n- wzgledny poziom mocy wyjsciowej\nAnalizatory obwodow\nAnalizatory widma\nAnalizatory systemow antenowych i kablowych\nOdbiorniki pomiarowe\nTestery radiokomunikacyjne\n- wzgledny poziom mocy mierzonej Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\nf = 9 kHz do 100 kHz -60 dB od -50 dB CMC 0,095 dB\nf = 9 kHz do 100 kHz -50 dB od -30 dB CMC 0,023 dB\nf = 9 kHz do 100 kHz 30 dB od 20 dB CMC 0,016 dB\nf = 100 kHz do 10 MHz -131 dB do -101 dB CMC 0,13 dB + δ\nf = 100 kHz do 10 MHz -101 dB do -60 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 100 kHz do 10 MHz -60 dB do 50 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 10 MHz do 3,05 GHz -134 dB do -104 dB CMC 0,13 dB + δ\nf = 10 MHz do 3,05 GHz -104 dB do -61 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 10 MHz do 3,05 GHz -61 dB do 50 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 3,05 GHz do 6,6 GHz -126 dB do -96 dB CMC 0,13 dB + δ\nf = 3,05 GHz do 6,6 GHz -96 dB do -57dB CMC (0,040 + 0,0005 - |P|) dB\nf = 3,05 GHz do 6,6 GHz -57dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 6,6 GHz do 13,2 GHz -117 dB do -87 dB CMC 0,12 dB + δ\nf = 6,6 GHz do 13,2 GHz -87 dB do -52 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 6,6 GHz do 13,2 GHz -52 dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 13,2 GHz do 19,2 GHz -109 dB do -79 dB CMC 0,12 dB + δ\nf = 13,2 GHz do 19,2 GHz -79 dB do -44 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 13,2 GHz do 19,2 GHz -44 dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 19,2 GHz do 26,5 GHz -102 dB do -72 dB CMC 0,12 dB + δ\nf = 19,2 GHz do 26,5 GHz -72 dB do -34 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 19,2 GHz do 26,5 GHz -34 dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nf = 26,5 GHz do 40 GHz -96 dB do -66 dB CMC 0,12 dB + δ\nf = 26,5 GHz do 40 GHz -66 dB do -51 dB CMC (0,040 + 0,0005 - |P|) dB\nf = 26,5 GHz do 40 GHz -51 dB do 30 dB CMC (0,009 + 0,0005 - |P|) dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/32\nLMEEiO/33\nLMEEiO/34\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/44\nLMEEiO/48","search_en":"Attenuators Couplers Amplifiers - scalar transmission Generators Network analysers Radio communication testers - relative output power level Network analysers Spectrum analysers Antenna and cable system analysers Measuring receivers Radio communication testers - relative measured power level Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) f = 9 kHz to 100 kHz f = 9 kHz to 100 kHz f = 9 kHz to 100 kHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 100 kHz to 10 MHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 10 MHz to 3,05 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 3,05 GHz to 6,6 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 6,6 GHz to 13,2 GHz f = 13,2 GHz to 19,2 GHz f = 13,2 GHz to 19,2 GHz f = 13,2 GHz to 19,2 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 19,2 GHz to 26,5 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz f = 26,5 GHz to 40 GHz LMEEiO/32 LMEEiO/33 LMEEiO/34 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/44 LMEEiO/48","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":44,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"f = 9 kHz bis 100 kHz","range":"-60 dB from -50 dB","cmc":"0,095 dB"},{"name":"f = 9 kHz bis 100 kHz","range":"-50 dB from -30 dB","cmc":"0,023 dB"},{"name":"f = 9 kHz bis 100 kHz","range":"30 dB from 20 dB","cmc":"0,016 dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-131 dB to -101 dB","cmc":"0,13 dB + δ"},{"name":"f = 100 kHz bis 10 MHz","range":"-101 dB to -60 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 100 kHz bis 10 MHz","range":"-60 dB to 50 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-134 dB to -104 dB","cmc":"0,13 dB + δ"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-104 dB to -61 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 10 MHz bis 3,05 GHz","range":"-61 dB to 50 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-126 dB to -96 dB","cmc":"0,13 dB + δ"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-96 dB to -57dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 3,05 GHz bis 6,6 GHz","range":"-57dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-117 dB to -87 dB","cmc":"0,12 dB + δ"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-87 dB to -52 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 6,6 GHz bis 13,2 GHz","range":"-52 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 13,2 GHz bis 19,2 GHz","range":"-109 dB to -79 dB","cmc":"0,12 dB + δ"},{"name":"f = 13,2 GHz bis 19,2 GHz","range":"-79 dB to -44 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 13,2 GHz bis 19,2 GHz","range":"-44 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-102 dB to -72 dB","cmc":"0,12 dB + δ"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-72 dB to -34 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 19,2 GHz bis 26,5 GHz","range":"-34 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-96 dB to -66 dB","cmc":"0,12 dB + δ"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-66 dB to -51 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 26,5 GHz bis 40 GHz","range":"-51 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Schalldämpfer Koppler Verstärker - skalare Transmission Generatoren Netzwerkanalysatoren Funkkommunikationstester - relativer Ausgangsleistungspegel Netzwerkanalysatoren Spektrumanalysatoren Analysatoren für Antennen- und Kabelsysteme Messempfänger Funkkommunikationstester - relativer gemessener Leistungspegel Kalibrierung — elektrische HF-Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 9 kHz bis 100 kHz f = 9 kHz bis 100 kHz f = 9 kHz bis 100 kHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 100 kHz bis 10 MHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 10 MHz bis 3,05 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 3,05 GHz bis 6,6 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 6,6 GHz bis 13,2 GHz f = 13,2 GHz bis 19,2 GHz f = 13,2 GHz bis 19,2 GHz f = 13,2 GHz bis 19,2 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 19,2 GHz bis 26,5 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz f = 26,5 GHz bis 40 GHz LMEEiO/32 LMEEiO/33 LMEEiO/34 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/44 LMEEiO/48","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Schalldämpfer\nKoppler\nVerstärker\n- skalare Transmission\nGeneratoren\nNetzwerkanalysatoren\nFunkkommunikationstester\n- relativer Ausgangsleistungspegel\nNetzwerkanalysatoren\nSpektrumanalysatoren\nAnalysatoren für Antennen- und Kabelsysteme\nMessempfänger\nFunkkommunikationstester\n- relativer gemessener Leistungspegel","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"f = 9 kHz 至 100 kHz","range":"-60 dB from -50 dB","cmc":"0,095 dB"},{"name":"f = 9 kHz 至 100 kHz","range":"-50 dB from -30 dB","cmc":"0,023 dB"},{"name":"f = 9 kHz 至 100 kHz","range":"30 dB from 20 dB","cmc":"0,016 dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-131 dB to -101 dB","cmc":"0,13 dB + δ"},{"name":"f = 100 kHz 至 10 MHz","range":"-101 dB to -60 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 100 kHz 至 10 MHz","range":"-60 dB to 50 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-134 dB to -104 dB","cmc":"0,13 dB + δ"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-104 dB to -61 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 10 MHz 至 3,05 GHz","range":"-61 dB to 50 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-126 dB to -96 dB","cmc":"0,13 dB + δ"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-96 dB to -57dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 3,05 GHz 至 6,6 GHz","range":"-57dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-117 dB to -87 dB","cmc":"0,12 dB + δ"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-87 dB to -52 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 6,6 GHz 至 13,2 GHz","range":"-52 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 13,2 GHz 至 19,2 GHz","range":"-109 dB to -79 dB","cmc":"0,12 dB + δ"},{"name":"f = 13,2 GHz 至 19,2 GHz","range":"-79 dB to -44 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 13,2 GHz 至 19,2 GHz","range":"-44 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-102 dB to -72 dB","cmc":"0,12 dB + δ"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-72 dB to -34 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 19,2 GHz 至 26,5 GHz","range":"-34 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-96 dB to -66 dB","cmc":"0,12 dB + δ"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-66 dB to -51 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 26,5 GHz 至 40 GHz","range":"-51 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"}],"regulatory_area_zh":"射频电学量","search_zh":"衰减器 耦合器 放大器 - 标量传输 发生器 网络分析仪 无线电通信测试仪 - 相对输出功率电平 网络分析仪 频谱分析仪 天线与电缆系统分析仪 测量接收机 无线电通信测试仪 - 相对测量功率电平 校准 — 射频电学量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 9 kHz 至 100 kHz f = 9 kHz 至 100 kHz f = 9 kHz 至 100 kHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 100 kHz 至 10 MHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 10 MHz 至 3,05 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 3,05 GHz 至 6,6 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 6,6 GHz 至 13,2 GHz f = 13,2 GHz 至 19,2 GHz f = 13,2 GHz 至 19,2 GHz f = 13,2 GHz 至 19,2 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 19,2 GHz 至 26,5 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz f = 26,5 GHz 至 40 GHz LMEEiO/32 LMEEiO/33 LMEEiO/34 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/44 LMEEiO/48","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"衰减器\n耦合器\n放大器\n- 标量传输\n发生器\n网络分析仪\n无线电通信测试仪\n- 相对输出功率电平\n网络分析仪\n频谱分析仪\n天线与电缆系统分析仪\n测量接收机\n无线电通信测试仪\n- 相对测量功率电平","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"f = 9 kHz až 100 kHz","range":"-60 dB from -50 dB","cmc":"0,095 dB"},{"name":"f = 9 kHz až 100 kHz","range":"-50 dB from -30 dB","cmc":"0,023 dB"},{"name":"f = 9 kHz až 100 kHz","range":"30 dB from 20 dB","cmc":"0,016 dB"},{"name":"f = 100 kHz až 10 MHz","range":"-131 dB to -101 dB","cmc":"0,13 dB + δ"},{"name":"f = 100 kHz až 10 MHz","range":"-101 dB to -60 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 100 kHz až 10 MHz","range":"-60 dB to 50 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-134 dB to -104 dB","cmc":"0,13 dB + δ"},{"name":"f = 10 MHz až 3,05 GHz","range":"-104 dB to -61 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 10 MHz až 3,05 GHz","range":"-61 dB to 50 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-126 dB to -96 dB","cmc":"0,13 dB + δ"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-96 dB to -57dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 3,05 GHz až 6,6 GHz","range":"-57dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-117 dB to -87 dB","cmc":"0,12 dB + δ"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-87 dB to -52 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 6,6 GHz až 13,2 GHz","range":"-52 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 13,2 GHz až 19,2 GHz","range":"-109 dB to -79 dB","cmc":"0,12 dB + δ"},{"name":"f = 13,2 GHz až 19,2 GHz","range":"-79 dB to -44 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 13,2 GHz až 19,2 GHz","range":"-44 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-102 dB to -72 dB","cmc":"0,12 dB + δ"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-72 dB to -34 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 19,2 GHz až 26,5 GHz","range":"-34 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-96 dB to -66 dB","cmc":"0,12 dB + δ"},{"name":"f = 26,5 GHz až 40 GHz","range":"-66 dB to -51 dB","cmc":"(0,040 + 0,0005 - |P|) dB"},{"name":"f = 26,5 GHz až 40 GHz","range":"-51 dB to 30 dB","cmc":"(0,009 + 0,0005 - |P|) dB"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Útlumové články Vazební členy Zesilovače - skalární přenos Generátory Obvodové analyzátory Radiokomunikační testery - relativní úroveň výstupního výkonu Obvodové analyzátory Spektrální analyzátory Analyzátory anténních a kabelových systémů Měřicí přijímače Radiokomunikační testery - relativní úroveň měřeného výkonu Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 9 kHz až 100 kHz f = 9 kHz až 100 kHz f = 9 kHz až 100 kHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 100 kHz až 10 MHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 10 MHz až 3,05 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 3,05 GHz až 6,6 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 6,6 GHz až 13,2 GHz f = 13,2 GHz až 19,2 GHz f = 13,2 GHz až 19,2 GHz f = 13,2 GHz až 19,2 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 19,2 GHz až 26,5 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz f = 26,5 GHz až 40 GHz LMEEiO/32 LMEEiO/33 LMEEiO/34 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/44 LMEEiO/48","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Útlumové články\nVazební členy\nZesilovače\n- skalární přenos\nGenerátory\nObvodové analyzátory\nRadiokomunikační testery\n- relativní úroveň výstupního výkonu\nObvodové analyzátory\nSpektrální analyzátory\nAnalyzátory anténních a kabelových systémů\nMěřicí přijímače\nRadiokomunikační testery\n- relativní úroveň měřeného výkonu"},{"_id":"4153c96cd7146895b6913d7f","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory\nTestery radiokomunikacyjne\n- głębokość generowanej modulacji AM\nAnalizatory modulacji analogowych\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\n- głębokość mierzonej modulacji AM","test_object_en":"Generators\nRadio communication testers\n- generated AM modulation depth\nAnalogue modulation analysers\nRadio communication testers\nMeasuring receivers\n- measured AM modulation depth","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"f = 50 kHz do 10 MHz; częstotliwość modulacji 20 Hz do 50 kHz; głębokość modulacji","range":"0 % do 99 %","cmc":"0,75 %"},{"name":"f = 10 MHz do 3 GHz; częstotliwość modulacji 30 Hz do 200 kHz; głębokość modulacji","range":"0 % do 99 %","cmc":"0,5 %"},{"name":"f = 3 GHz do 5,2 GHz; częstotliwość modulacji 30 Hz do 200 kHz; głębokość modulacji","range":"0 % do 99 %","cmc":"0,8 %"},{"name":"f = 5,2 GHz do 26,5 GHz; częstotliwość modulacji 50 Hz do 100 kHz; głębokość modulacji","range":"5 % do 99 %","cmc":"1,5 %"}],"parameters_en":[{"name":"f = 50 kHz to 10 MHz; modulation frequency 20 Hz to 50 kHz; modulation depth","range":"0 % to 99 %","cmc":"0,75 %"},{"name":"f = 10 MHz to 3 GHz; modulation frequency 30 Hz to 200 kHz; modulation depth","range":"0 % to 99 %","cmc":"0,5 %"},{"name":"f = 3 GHz to 5,2 GHz; modulation frequency 30 Hz to 200 kHz; modulation depth","range":"0 % to 99 %","cmc":"0,8 %"},{"name":"f = 5,2 GHz to 26,5 GHz; modulation frequency 50 Hz to 100 kHz; modulation depth","range":"5 % to 99 %","cmc":"1,5 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 50 kHz do 10 MHz; częstotliwość modulacji 20 Hz do 50 kHz; głębokość modulacji 0 % do 99 % CMC 0,75 %\nf = 10 MHz do 3 GHz; częstotliwość modulacji 30 Hz do 200 kHz; głębokość modulacji 0 % do 99 % CMC 0,5 %\nf = 3 GHz do 5,2 GHz; częstotliwość modulacji 30 Hz do 200 kHz; głębokość modulacji 0 % do 99 % CMC 0,8 %\nf = 5,2 GHz do 26,5 GHz; częstotliwość modulacji 50 Hz do 100 kHz; głębokość modulacji 5 % do 99 % CMC 1,5 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/32\nLMEEiO/44","norm_bases":["LMEEiO/32","LMEEiO/44"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Generatory\nTestery radiokomunikacyjne\n- głębokość generowanej modulacji AM\nAnalizatory modulacji analogowych\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\n- głębokość mierzonej modulacji AM Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 50 kHz do 10 MHz; częstotliwość modulacji 20 Hz do 50 kHz; głębokość modulacji 0 % do 99 % CMC 0,75 %\nf = 10 MHz do 3 GHz; częstotliwość modulacji 30 Hz do 200 kHz; głębokość modulacji 0 % do 99 % CMC 0,5 %\nf = 3 GHz do 5,2 GHz; częstotliwość modulacji 30 Hz do 200 kHz; głębokość modulacji 0 % do 99 % CMC 0,8 %\nf = 5,2 GHz do 26,5 GHz; częstotliwość modulacji 50 Hz do 100 kHz; głębokość modulacji 5 % do 99 % CMC 1,5 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/32\nLMEEiO/44 Generatory\nTestery radiokomunikacyjne\n- glebokosc generowanej modulacji AM\nAnalizatory modulacji analogowych\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\n- glebokosc mierzonej modulacji AM Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\nf = 50 kHz do 10 MHz; czestotliwosc modulacji 20 Hz do 50 kHz; glebokosc modulacji 0 % do 99 % CMC 0,75 %\nf = 10 MHz do 3 GHz; czestotliwosc modulacji 30 Hz do 200 kHz; glebokosc modulacji 0 % do 99 % CMC 0,5 %\nf = 3 GHz do 5,2 GHz; czestotliwosc modulacji 30 Hz do 200 kHz; glebokosc modulacji 0 % do 99 % CMC 0,8 %\nf = 5,2 GHz do 26,5 GHz; czestotliwosc modulacji 50 Hz do 100 kHz; glebokosc modulacji 5 % do 99 % CMC 1,5 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/32\nLMEEiO/44","search_en":"Generators Radio communication testers - generated AM modulation depth Analogue modulation analysers Radio communication testers Measuring receivers - measured AM modulation depth Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 kHz to 10 MHz; modulation frequency 20 Hz to 50 kHz; modulation depth f = 10 MHz to 3 GHz; modulation frequency 30 Hz to 200 kHz; modulation depth f = 3 GHz to 5,2 GHz; modulation frequency 30 Hz to 200 kHz; modulation depth f = 5,2 GHz to 26,5 GHz; modulation frequency 50 Hz to 100 kHz; modulation depth LMEEiO/32 LMEEiO/44","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":45,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"f = 50 kHz bis 10 MHz; Modulationsfrequenz 20 Hz bis 50 kHz; Modulationsgrad","range":"0 % to 99 %","cmc":"0,75 %"},{"name":"f = 10 MHz bis 3 GHz; Modulationsfrequenz 30 Hz bis 200 kHz; Modulationsgrad","range":"0 % to 99 %","cmc":"0,5 %"},{"name":"f = 3 GHz bis 5,2 GHz; Modulationsfrequenz 30 Hz bis 200 kHz; Modulationsgrad","range":"0 % to 99 %","cmc":"0,8 %"},{"name":"f = 5,2 GHz bis 26,5 GHz; Modulationsfrequenz 50 Hz bis 100 kHz; Modulationsgrad","range":"5 % to 99 %","cmc":"1,5 %"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Generatoren Funkkommunikationstester - Modulationsgrad der erzeugten AM-Modulation Analysatoren für analoge Modulation Funkkommunikationstester Messempfänger - Modulationsgrad der gemessenen AM-Modulation Kalibrierung — elektrische HF-Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 kHz bis 10 MHz; Modulationsfrequenz 20 Hz bis 50 kHz; Modulationsgrad f = 10 MHz bis 3 GHz; Modulationsfrequenz 30 Hz bis 200 kHz; Modulationsgrad f = 3 GHz bis 5,2 GHz; Modulationsfrequenz 30 Hz bis 200 kHz; Modulationsgrad f = 5,2 GHz bis 26,5 GHz; Modulationsfrequenz 50 Hz bis 100 kHz; Modulationsgrad LMEEiO/32 LMEEiO/44","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Generatoren\nFunkkommunikationstester\n- Modulationsgrad der erzeugten AM-Modulation\nAnalysatoren für analoge Modulation\nFunkkommunikationstester\nMessempfänger\n- Modulationsgrad der gemessenen AM-Modulation","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"f = 50 kHz 至 10 MHz; 调制频率 20 Hz 至 50 kHz; 调制深度","range":"0 % to 99 %","cmc":"0,75 %"},{"name":"f = 10 MHz 至 3 GHz; 调制频率 30 Hz 至 200 kHz; 调制深度","range":"0 % to 99 %","cmc":"0,5 %"},{"name":"f = 3 GHz 至 5,2 GHz; 调制频率 30 Hz 至 200 kHz; 调制深度","range":"0 % to 99 %","cmc":"0,8 %"},{"name":"f = 5,2 GHz 至 26,5 GHz; 调制频率 50 Hz 至 100 kHz; 调制深度","range":"5 % to 99 %","cmc":"1,5 %"}],"regulatory_area_zh":"射频电学量","search_zh":"发生器 无线电通信测试仪 - 生成的调幅（AM）深度 模拟调制分析仪 无线电通信测试仪 测量接收机 - 测量的调幅（AM）深度 校准 — 射频电学量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 kHz 至 10 MHz; 调制频率 20 Hz 至 50 kHz; 调制深度 f = 10 MHz 至 3 GHz; 调制频率 30 Hz 至 200 kHz; 调制深度 f = 3 GHz 至 5,2 GHz; 调制频率 30 Hz 至 200 kHz; 调制深度 f = 5,2 GHz 至 26,5 GHz; 调制频率 50 Hz 至 100 kHz; 调制深度 LMEEiO/32 LMEEiO/44","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"发生器\n无线电通信测试仪\n- 生成的调幅（AM）深度\n模拟调制分析仪\n无线电通信测试仪\n测量接收机\n- 测量的调幅（AM）深度","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"f = 50 kHz až 10 MHz; modulační kmitočet 20 Hz až 50 kHz; hloubka modulace","range":"0 % to 99 %","cmc":"0,75 %"},{"name":"f = 10 MHz až 3 GHz; modulační kmitočet 30 Hz až 200 kHz; hloubka modulace","range":"0 % to 99 %","cmc":"0,5 %"},{"name":"f = 3 GHz až 5,2 GHz; modulační kmitočet 30 Hz až 200 kHz; hloubka modulace","range":"0 % to 99 %","cmc":"0,8 %"},{"name":"f = 5,2 GHz až 26,5 GHz; modulační kmitočet 50 Hz až 100 kHz; hloubka modulace","range":"5 % to 99 %","cmc":"1,5 %"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Generátory Radiokomunikační testery - hloubka generované modulace AM Analyzátory analogové modulace Radiokomunikační testery Měřicí přijímače - hloubka měřené modulace AM Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 kHz až 10 MHz; modulační kmitočet 20 Hz až 50 kHz; hloubka modulace f = 10 MHz až 3 GHz; modulační kmitočet 30 Hz až 200 kHz; hloubka modulace f = 3 GHz až 5,2 GHz; modulační kmitočet 30 Hz až 200 kHz; hloubka modulace f = 5,2 GHz až 26,5 GHz; modulační kmitočet 50 Hz až 100 kHz; hloubka modulace LMEEiO/32 LMEEiO/44","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Generátory\nRadiokomunikační testery\n- hloubka generované modulace AM\nAnalyzátory analogové modulace\nRadiokomunikační testery\nMěřicí přijímače\n- hloubka měřené modulace AM"},{"_id":"6e6536f57e0a0778c5b1bd27","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory\nTestery radiokomunikacyjne\n- dewiacja częstotliwości generowanej modulacji FM\nAnalizatory modulacji analogowych\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\n- dewiacja częstotliwości mierzonej modulacji FM","test_object_en":"Generators\nRadio communication testers\n- generated FM frequency deviation\nAnalogue modulation analysers\nRadio communication testers\nMeasuring receivers\n- measured FM frequency deviation","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"f = 50 kHz do 10 MHz; częstotliwość modulacji 10 Hz do 50 kHz; dewiacja częstotliwości","range":"100 Hz do 150 kHz","cmc":"0,5 %"},{"name":"f = 10 MHz do 5,2 GHz; częstotliwość modulacji 10 Hz do 200 kHz; dewiacja częstotliwości","range":"100 Hz do 700 kHz","cmc":"0,5 %"},{"name":"f = 5,2 GHz do 26,5 GHz; częstotliwość modulacji 50 Hz do 200 kHz; dewiacja częstotliwości","range":"250 kHz do 400 kHz","cmc":"1,0 %"}],"parameters_en":[{"name":"f = 50 kHz to 10 MHz; modulation frequency 10 Hz to 50 kHz; frequency deviation","range":"100 Hz to 150 kHz","cmc":"0,5 %"},{"name":"f = 10 MHz to 5,2 GHz; modulation frequency 10 Hz to 200 kHz; frequency deviation","range":"100 Hz to 700 kHz","cmc":"0,5 %"},{"name":"f = 5,2 GHz to 26,5 GHz; modulation frequency 50 Hz to 200 kHz; frequency deviation","range":"250 kHz to 400 kHz","cmc":"1,0 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 50 kHz do 10 MHz; częstotliwość modulacji 10 Hz do 50 kHz; dewiacja częstotliwości 100 Hz do 150 kHz CMC 0,5 %\nf = 10 MHz do 5,2 GHz; częstotliwość modulacji 10 Hz do 200 kHz; dewiacja częstotliwości 100 Hz do 700 kHz CMC 0,5 %\nf = 5,2 GHz do 26,5 GHz; częstotliwość modulacji 50 Hz do 200 kHz; dewiacja częstotliwości 250 kHz do 400 kHz CMC 1,0 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/32\nLMEEiO/44","norm_bases":["LMEEiO/32","LMEEiO/44"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Generatory\nTestery radiokomunikacyjne\n- dewiacja częstotliwości generowanej modulacji FM\nAnalizatory modulacji analogowych\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\n- dewiacja częstotliwości mierzonej modulacji FM Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 50 kHz do 10 MHz; częstotliwość modulacji 10 Hz do 50 kHz; dewiacja częstotliwości 100 Hz do 150 kHz CMC 0,5 %\nf = 10 MHz do 5,2 GHz; częstotliwość modulacji 10 Hz do 200 kHz; dewiacja częstotliwości 100 Hz do 700 kHz CMC 0,5 %\nf = 5,2 GHz do 26,5 GHz; częstotliwość modulacji 50 Hz do 200 kHz; dewiacja częstotliwości 250 kHz do 400 kHz CMC 1,0 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/32\nLMEEiO/44 Generatory\nTestery radiokomunikacyjne\n- dewiacja czestotliwosci generowanej modulacji FM\nAnalizatory modulacji analogowych\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\n- dewiacja czestotliwosci mierzonej modulacji FM Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\nf = 50 kHz do 10 MHz; czestotliwosc modulacji 10 Hz do 50 kHz; dewiacja czestotliwosci 100 Hz do 150 kHz CMC 0,5 %\nf = 10 MHz do 5,2 GHz; czestotliwosc modulacji 10 Hz do 200 kHz; dewiacja czestotliwosci 100 Hz do 700 kHz CMC 0,5 %\nf = 5,2 GHz do 26,5 GHz; czestotliwosc modulacji 50 Hz do 200 kHz; dewiacja czestotliwosci 250 kHz do 400 kHz CMC 1,0 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/32\nLMEEiO/44","search_en":"Generators Radio communication testers - generated FM frequency deviation Analogue modulation analysers Radio communication testers Measuring receivers - measured FM frequency deviation Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 kHz to 10 MHz; modulation frequency 10 Hz to 50 kHz; frequency deviation f = 10 MHz to 5,2 GHz; modulation frequency 10 Hz to 200 kHz; frequency deviation f = 5,2 GHz to 26,5 GHz; modulation frequency 50 Hz to 200 kHz; frequency deviation LMEEiO/32 LMEEiO/44","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":46,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"f = 50 kHz bis 10 MHz; Modulationsfrequenz 10 Hz bis 50 kHz; Frequenzhub","range":"100 Hz to 150 kHz","cmc":"0,5 %"},{"name":"f = 10 MHz bis 5,2 GHz; Modulationsfrequenz 10 Hz bis 200 kHz; Frequenzhub","range":"100 Hz to 700 kHz","cmc":"0,5 %"},{"name":"f = 5,2 GHz bis 26,5 GHz; Modulationsfrequenz 50 Hz bis 200 kHz; Frequenzhub","range":"250 kHz to 400 kHz","cmc":"1,0 %"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Generatoren Funkkommunikationstester - Frequenzhub der erzeugten FM-Modulation Analysatoren für analoge Modulation Funkkommunikationstester Messempfänger - Frequenzhub der gemessenen FM-Modulation Kalibrierung — elektrische HF-Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 kHz bis 10 MHz; Modulationsfrequenz 10 Hz bis 50 kHz; Frequenzhub f = 10 MHz bis 5,2 GHz; Modulationsfrequenz 10 Hz bis 200 kHz; Frequenzhub f = 5,2 GHz bis 26,5 GHz; Modulationsfrequenz 50 Hz bis 200 kHz; Frequenzhub LMEEiO/32 LMEEiO/44","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Generatoren\nFunkkommunikationstester\n- Frequenzhub der erzeugten FM-Modulation\nAnalysatoren für analoge Modulation\nFunkkommunikationstester\nMessempfänger\n- Frequenzhub der gemessenen FM-Modulation","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"f = 50 kHz 至 10 MHz; 调制频率 10 Hz 至 50 kHz; 频偏","range":"100 Hz to 150 kHz","cmc":"0,5 %"},{"name":"f = 10 MHz 至 5,2 GHz; 调制频率 10 Hz 至 200 kHz; 频偏","range":"100 Hz to 700 kHz","cmc":"0,5 %"},{"name":"f = 5,2 GHz 至 26,5 GHz; 调制频率 50 Hz 至 200 kHz; 频偏","range":"250 kHz to 400 kHz","cmc":"1,0 %"}],"regulatory_area_zh":"射频电学量","search_zh":"发生器 无线电通信测试仪 - 生成的调频（FM）频偏 模拟调制分析仪 无线电通信测试仪 测量接收机 - 测量的调频（FM）频偏 校准 — 射频电学量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 kHz 至 10 MHz; 调制频率 10 Hz 至 50 kHz; 频偏 f = 10 MHz 至 5,2 GHz; 调制频率 10 Hz 至 200 kHz; 频偏 f = 5,2 GHz 至 26,5 GHz; 调制频率 50 Hz 至 200 kHz; 频偏 LMEEiO/32 LMEEiO/44","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"发生器\n无线电通信测试仪\n- 生成的调频（FM）频偏\n模拟调制分析仪\n无线电通信测试仪\n测量接收机\n- 测量的调频（FM）频偏","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"f = 50 kHz až 10 MHz; modulační kmitočet 10 Hz až 50 kHz; kmitočtový zdvih","range":"100 Hz to 150 kHz","cmc":"0,5 %"},{"name":"f = 10 MHz až 5,2 GHz; modulační kmitočet 10 Hz až 200 kHz; kmitočtový zdvih","range":"100 Hz to 700 kHz","cmc":"0,5 %"},{"name":"f = 5,2 GHz až 26,5 GHz; modulační kmitočet 50 Hz až 200 kHz; kmitočtový zdvih","range":"250 kHz to 400 kHz","cmc":"1,0 %"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Generátory Radiokomunikační testery - kmitočtový zdvih generované modulace FM Analyzátory analogové modulace Radiokomunikační testery Měřicí přijímače - kmitočtový zdvih měřené modulace FM Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 kHz až 10 MHz; modulační kmitočet 10 Hz až 50 kHz; kmitočtový zdvih f = 10 MHz až 5,2 GHz; modulační kmitočet 10 Hz až 200 kHz; kmitočtový zdvih f = 5,2 GHz až 26,5 GHz; modulační kmitočet 50 Hz až 200 kHz; kmitočtový zdvih LMEEiO/32 LMEEiO/44","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Generátory\nRadiokomunikační testery\n- kmitočtový zdvih generované modulace FM\nAnalyzátory analogové modulace\nRadiokomunikační testery\nMěřicí přijímače\n- kmitočtový zdvih měřené modulace FM"},{"_id":"0d53acc60c528590a9e2eecf","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory\nTestery radiokomunikacyjne\n- dewiacja fazy generowanej modulacji FM\nAnalizatory modulacji analogowych\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\n- dewiacja fazy mierzonej modulacji FM","test_object_en":"Generators\nRadio communication testers\n- generated FM phase deviation\nAnalogue modulation analysers\nRadio communication testers\nMeasuring receivers\n- measured FM phase deviation","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"f = 50 kHz do 10 MHz; częstotliwość modulacji 10 Hz do 20 kHz; dewiacja fazy","range":"0,01 rad do 450 rad","cmc":"1,0 %"},{"name":"f = 10 MHz do 5,2 GHz; częstotliwość modulacji 10 Hz do 100 kHz; dewiacja fazy","range":"0,01 rad do 24999 rad","cmc":"1,0 %"},{"name":"f = 5,2 GHz do 26,5 GHz; częstotliwość modulacji 200 Hz do 20 kHz; dewiacja fazy","range":"0,3 rad do 24999 rad","cmc":"1,0 %"}],"parameters_en":[{"name":"f = 50 kHz to 10 MHz; modulation frequency 10 Hz to 20 kHz; phase deviation","range":"0,01 rad to 450 rad","cmc":"1,0 %"},{"name":"f = 10 MHz to 5,2 GHz; modulation frequency 10 Hz to 100 kHz; phase deviation","range":"0,01 rad to 24999 rad","cmc":"1,0 %"},{"name":"f = 5,2 GHz to 26,5 GHz; modulation frequency 200 Hz to 20 kHz; phase deviation","range":"0,3 rad to 24999 rad","cmc":"1,0 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 50 kHz do 10 MHz; częstotliwość modulacji 10 Hz do 20 kHz; dewiacja fazy 0,01 rad do 450 rad CMC 1,0 %\nf = 10 MHz do 5,2 GHz; częstotliwość modulacji 10 Hz do 100 kHz; dewiacja fazy 0,01 rad do 24999 rad CMC 1,0 %\nf = 5,2 GHz do 26,5 GHz; częstotliwość modulacji 200 Hz do 20 kHz; dewiacja fazy 0,3 rad do 24999 rad CMC 1,0 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/32\nLMEEiO/44","norm_bases":["LMEEiO/32","LMEEiO/44"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Generatory\nTestery radiokomunikacyjne\n- dewiacja fazy generowanej modulacji FM\nAnalizatory modulacji analogowych\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\n- dewiacja fazy mierzonej modulacji FM Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nf = 50 kHz do 10 MHz; częstotliwość modulacji 10 Hz do 20 kHz; dewiacja fazy 0,01 rad do 450 rad CMC 1,0 %\nf = 10 MHz do 5,2 GHz; częstotliwość modulacji 10 Hz do 100 kHz; dewiacja fazy 0,01 rad do 24999 rad CMC 1,0 %\nf = 5,2 GHz do 26,5 GHz; częstotliwość modulacji 200 Hz do 20 kHz; dewiacja fazy 0,3 rad do 24999 rad CMC 1,0 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/32\nLMEEiO/44 Generatory\nTestery radiokomunikacyjne\n- dewiacja fazy generowanej modulacji FM\nAnalizatory modulacji analogowych\nTestery radiokomunikacyjne\nOdbiorniki pomiarowe\n- dewiacja fazy mierzonej modulacji FM Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\nf = 50 kHz do 10 MHz; czestotliwosc modulacji 10 Hz do 20 kHz; dewiacja fazy 0,01 rad do 450 rad CMC 1,0 %\nf = 10 MHz do 5,2 GHz; czestotliwosc modulacji 10 Hz do 100 kHz; dewiacja fazy 0,01 rad do 24999 rad CMC 1,0 %\nf = 5,2 GHz do 26,5 GHz; czestotliwosc modulacji 200 Hz do 20 kHz; dewiacja fazy 0,3 rad do 24999 rad CMC 1,0 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/32\nLMEEiO/44","search_en":"Generators Radio communication testers - generated FM phase deviation Analogue modulation analysers Radio communication testers Measuring receivers - measured FM phase deviation Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) f = 50 kHz to 10 MHz; modulation frequency 10 Hz to 20 kHz; phase deviation f = 10 MHz to 5,2 GHz; modulation frequency 10 Hz to 100 kHz; phase deviation f = 5,2 GHz to 26,5 GHz; modulation frequency 200 Hz to 20 kHz; phase deviation LMEEiO/32 LMEEiO/44","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":47,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"f = 50 kHz bis 10 MHz; Modulationsfrequenz 10 Hz bis 20 kHz; Phasenhub","range":"0,01 rad to 450 rad","cmc":"1,0 %"},{"name":"f = 10 MHz bis 5,2 GHz; Modulationsfrequenz 10 Hz bis 100 kHz; Phasenhub","range":"0,01 rad to 24999 rad","cmc":"1,0 %"},{"name":"f = 5,2 GHz bis 26,5 GHz; Modulationsfrequenz 200 Hz bis 20 kHz; Phasenhub","range":"0,3 rad to 24999 rad","cmc":"1,0 %"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Generatoren Funkkommunikationstester - Phasenhub der erzeugten FM-Modulation Analysatoren für analoge Modulation Funkkommunikationstester Messempfänger - Phasenhub der gemessenen FM-Modulation Kalibrierung — elektrische HF-Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) f = 50 kHz bis 10 MHz; Modulationsfrequenz 10 Hz bis 20 kHz; Phasenhub f = 10 MHz bis 5,2 GHz; Modulationsfrequenz 10 Hz bis 100 kHz; Phasenhub f = 5,2 GHz bis 26,5 GHz; Modulationsfrequenz 200 Hz bis 20 kHz; Phasenhub LMEEiO/32 LMEEiO/44","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Generatoren\nFunkkommunikationstester\n- Phasenhub der erzeugten FM-Modulation\nAnalysatoren für analoge Modulation\nFunkkommunikationstester\nMessempfänger\n- Phasenhub der gemessenen FM-Modulation","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"f = 50 kHz 至 10 MHz; 调制频率 10 Hz 至 20 kHz; 相偏","range":"0,01 rad to 450 rad","cmc":"1,0 %"},{"name":"f = 10 MHz 至 5,2 GHz; 调制频率 10 Hz 至 100 kHz; 相偏","range":"0,01 rad to 24999 rad","cmc":"1,0 %"},{"name":"f = 5,2 GHz 至 26,5 GHz; 调制频率 200 Hz 至 20 kHz; 相偏","range":"0,3 rad to 24999 rad","cmc":"1,0 %"}],"regulatory_area_zh":"射频电学量","search_zh":"发生器 无线电通信测试仪 - 生成的调频（FM）相偏 模拟调制分析仪 无线电通信测试仪 测量接收机 - 测量的调频（FM）相偏 校准 — 射频电学量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) f = 50 kHz 至 10 MHz; 调制频率 10 Hz 至 20 kHz; 相偏 f = 10 MHz 至 5,2 GHz; 调制频率 10 Hz 至 100 kHz; 相偏 f = 5,2 GHz 至 26,5 GHz; 调制频率 200 Hz 至 20 kHz; 相偏 LMEEiO/32 LMEEiO/44","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"发生器\n无线电通信测试仪\n- 生成的调频（FM）相偏\n模拟调制分析仪\n无线电通信测试仪\n测量接收机\n- 测量的调频（FM）相偏","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"f = 50 kHz až 10 MHz; modulační kmitočet 10 Hz až 20 kHz; fázový zdvih","range":"0,01 rad to 450 rad","cmc":"1,0 %"},{"name":"f = 10 MHz až 5,2 GHz; modulační kmitočet 10 Hz až 100 kHz; fázový zdvih","range":"0,01 rad to 24999 rad","cmc":"1,0 %"},{"name":"f = 5,2 GHz až 26,5 GHz; modulační kmitočet 200 Hz až 20 kHz; fázový zdvih","range":"0,3 rad to 24999 rad","cmc":"1,0 %"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Generátory Radiokomunikační testery - fázový zdvih generované modulace FM Analyzátory analogové modulace Radiokomunikační testery Měřicí přijímače - fázový zdvih měřené modulace FM Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) f = 50 kHz až 10 MHz; modulační kmitočet 10 Hz až 20 kHz; fázový zdvih f = 10 MHz až 5,2 GHz; modulační kmitočet 10 Hz až 100 kHz; fázový zdvih f = 5,2 GHz až 26,5 GHz; modulační kmitočet 200 Hz až 20 kHz; fázový zdvih LMEEiO/32 LMEEiO/44","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Generátory\nRadiokomunikační testery\n- fázový zdvih generované modulace FM\nAnalyzátory analogové modulace\nRadiokomunikační testery\nMěřicí přijímače\n- fázový zdvih měřené modulace FM"},{"_id":"62f990047e159ef085621894","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory\nTestery radiokomunikacyjne\n- generatory zniekształceń sygnału","test_object_en":"Generators\nRadio communication testers\n- signal distortion generators","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"","range":"-80 dB do 0 dB","cmc":"1 dB"}],"parameters_en":[{"name":"","range":"-80 dB to 0 dB","cmc":"1 dB"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\n-80 dB do 0 dB CMC 1 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/32\nLMEEiO/44","norm_bases":["LMEEiO/32","LMEEiO/44"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Generatory\nTestery radiokomunikacyjne\n- generatory zniekształceń sygnału Wzorcowanie — Wielkości elektryczne w.cz.\n-80 dB do 0 dB CMC 1 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/32\nLMEEiO/44 Generatory\nTestery radiokomunikacyjne\n- generatory znieksztalcen sygnalu Wzorcowanie — Wielkosci elektryczne w.cz.\n-80 dB do 0 dB CMC 1 dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/32\nLMEEiO/44","search_en":"Generators Radio communication testers - signal distortion generators Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/32 LMEEiO/44","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":48,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"","range":"-80 dB to 0 dB","cmc":"1 dB"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Generatoren Funkkommunikationstester - Signalverzerrungsgeneratoren Kalibrierung — elektrische HF-Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/32 LMEEiO/44","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Generatoren\nFunkkommunikationstester\n- Signalverzerrungsgeneratoren","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"","range":"-80 dB to 0 dB","cmc":"1 dB"}],"regulatory_area_zh":"射频电学量","search_zh":"发生器 无线电通信测试仪 - 信号失真发生器 校准 — 射频电学量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/32 LMEEiO/44","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"发生器\n无线电通信测试仪\n- 信号失真发生器","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"","range":"-80 dB to 0 dB","cmc":"1 dB"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Generátory Radiokomunikační testery - generátory zkreslení signálu Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/32 LMEEiO/44","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Generátory\nRadiokomunikační testery\n- generátory zkreslení signálu"},{"_id":"8271bec487a8e884d854395c","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Testery radiokomunikacyjne\n- częstotliwość modulacji (AM, FM, PM)","test_object_en":"Radio communication testers\n- modulation frequency (AM, FM, PM)","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"","range":"20 Hz do 200 kHz","cmc":"0,06 Hz"}],"parameters_en":[{"name":"","range":"20 Hz to 200 kHz","cmc":"0,06 Hz"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\n20 Hz do 200 kHz CMC 0,06 Hz\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/32\nLMEEiO/44","norm_bases":["LMEEiO/32","LMEEiO/44"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Testery radiokomunikacyjne\n- częstotliwość modulacji (AM, FM, PM) Wzorcowanie — Wielkości elektryczne w.cz.\n20 Hz do 200 kHz CMC 0,06 Hz\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/32\nLMEEiO/44 Testery radiokomunikacyjne\n- czestotliwosc modulacji (AM, FM, PM) Wzorcowanie — Wielkosci elektryczne w.cz.\n20 Hz do 200 kHz CMC 0,06 Hz\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/32\nLMEEiO/44","search_en":"Radio communication testers - modulation frequency (AM, FM, PM) Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/32 LMEEiO/44","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":49,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"","range":"20 Hz to 200 kHz","cmc":"0,06 Hz"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Funkkommunikationstester - Modulationsfrequenz (AM, FM, PM) Kalibrierung — elektrische HF-Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/32 LMEEiO/44","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Funkkommunikationstester\n- Modulationsfrequenz (AM, FM, PM)","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"","range":"20 Hz to 200 kHz","cmc":"0,06 Hz"}],"regulatory_area_zh":"射频电学量","search_zh":"无线电通信测试仪 - 调制频率（AM、FM、PM） 校准 — 射频电学量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/32 LMEEiO/44","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"无线电通信测试仪\n- 调制频率（AM、FM、PM）","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"","range":"20 Hz to 200 kHz","cmc":"0,06 Hz"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Radiokomunikační testery - modulační kmitočet (AM, FM, PM) Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/32 LMEEiO/44","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Radiokomunikační testery\n- modulační kmitočet (AM, FM, PM)"},{"_id":"7e1ea5b7a535cfe7ed989702","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory zniekształceń\nAnalizatory modulacji\nTestery radiokomunikacyjne\n- mierzone zniekształcenia sygnału","test_object_en":"Distortion analysers\nModulation analysers\nRadio communication testers\n- measured signal distortion","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"","range":"< 50 kHz","cmc":"0,5 dB"},{"name":"","range":"50 kHz do 100 kHz","cmc":"0,7 dB"},{"name":"","range":"100 kHz do 300 kHz","cmc":"1,5 dB"}],"parameters_en":[{"name":"","range":"< 50 kHz","cmc":"0,5 dB"},{"name":"","range":"50 kHz to 100 kHz","cmc":"0,7 dB"},{"name":"","range":"100 kHz to 300 kHz","cmc":"1,5 dB"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\n< 50 kHz CMC 0,5 dB\n50 kHz do 100 kHz CMC 0,7 dB\n100 kHz do 300 kHz CMC 1,5 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/44","norm_bases":["LMEEiO/44"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Analizatory zniekształceń\nAnalizatory modulacji\nTestery radiokomunikacyjne\n- mierzone zniekształcenia sygnału Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\n< 50 kHz CMC 0,5 dB\n50 kHz do 100 kHz CMC 0,7 dB\n100 kHz do 300 kHz CMC 1,5 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/44 Analizatory znieksztalcen\nAnalizatory modulacji\nTestery radiokomunikacyjne\n- mierzone znieksztalcenia sygnalu Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\n< 50 kHz CMC 0,5 dB\n50 kHz do 100 kHz CMC 0,7 dB\n100 kHz do 300 kHz CMC 1,5 dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/44","search_en":"Distortion analysers Modulation analysers Radio communication testers - measured signal distortion Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/44","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":50,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"","range":"< 50 kHz","cmc":"0,5 dB"},{"name":"","range":"50 kHz bis 100 kHz","cmc":"0,7 dB"},{"name":"","range":"100 kHz bis 300 kHz","cmc":"1,5 dB"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Verzerrungsanalysatoren Modulationsanalysatoren Funkkommunikationstester - gemessene Signalverzerrungen Kalibrierung — elektrische HF-Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/44","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Verzerrungsanalysatoren\nModulationsanalysatoren\nFunkkommunikationstester\n- gemessene Signalverzerrungen","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"","range":"< 50 kHz","cmc":"0,5 dB"},{"name":"","range":"50 kHz 至 100 kHz","cmc":"0,7 dB"},{"name":"","range":"100 kHz 至 300 kHz","cmc":"1,5 dB"}],"regulatory_area_zh":"射频电学量","search_zh":"失真分析仪 调制分析仪 无线电通信测试仪 - 测量的信号失真 校准 — 射频电学量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/44","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"失真分析仪\n调制分析仪\n无线电通信测试仪\n- 测量的信号失真","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"","range":"< 50 kHz","cmc":"0,5 dB"},{"name":"","range":"50 kHz až 100 kHz","cmc":"0,7 dB"},{"name":"","range":"100 kHz až 300 kHz","cmc":"1,5 dB"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Analyzátory zkreslení Analyzátory modulace Radiokomunikační testery - měřené zkreslení signálu Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/44","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analyzátory zkreslení\nAnalyzátory modulace\nRadiokomunikační testery\n- měřené zkreslení signálu"},{"_id":"c6d81e280a4434ee6a893a90","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Czujniki mocy\n- współczynnik kalibracji","test_object_en":"Power sensors\n- calibration factor","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"10 % do 150 %","range":"9 kHz do 300 MHz","cmc":"0,56 %"},{"name":"10 % do 150 %","range":"300 MHz do 8,5 GHz","cmc":"0,71 %"},{"name":"10 % do 150 %","range":"8,5 GHz do 12,5 GHz","cmc":"0,85 %"},{"name":"10 % do 150 %","range":"12,5 GHz do 18,0 GHz","cmc":"0,91 %"},{"name":"10 % do 150 %","range":"18,0 GHz do 26,5 GHz","cmc":"1,7 %"},{"name":"10 % do 150 %","range":"26,5 GHz do 40 GHz","cmc":"2,5 %"},{"name":"10 % do 150 %","range":"40 GHz do 50 GHz","cmc":"3,3 %"}],"parameters_en":[{"name":"10 % to 150 %","range":"9 kHz to 300 MHz","cmc":"0,56 %"},{"name":"10 % to 150 %","range":"300 MHz to 8,5 GHz","cmc":"0,71 %"},{"name":"10 % to 150 %","range":"8,5 GHz to 12,5 GHz","cmc":"0,85 %"},{"name":"10 % to 150 %","range":"12,5 GHz to 18,0 GHz","cmc":"0,91 %"},{"name":"10 % to 150 %","range":"18,0 GHz to 26,5 GHz","cmc":"1,7 %"},{"name":"10 % to 150 %","range":"26,5 GHz to 40 GHz","cmc":"2,5 %"},{"name":"10 % to 150 %","range":"40 GHz to 50 GHz","cmc":"3,3 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\n10 % do 150 % 9 kHz do 300 MHz CMC 0,56 %\n10 % do 150 % 300 MHz do 8,5 GHz CMC 0,71 %\n10 % do 150 % 8,5 GHz do 12,5 GHz CMC 0,85 %\n10 % do 150 % 12,5 GHz do 18,0 GHz CMC 0,91 %\n10 % do 150 % 18,0 GHz do 26,5 GHz CMC 1,7 %\n10 % do 150 % 26,5 GHz do 40 GHz CMC 2,5 %\n10 % do 150 % 40 GHz do 50 GHz CMC 3,3 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/33","norm_bases":["LMEEiO/33"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Czujniki mocy\n- współczynnik kalibracji Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\n10 % do 150 % 9 kHz do 300 MHz CMC 0,56 %\n10 % do 150 % 300 MHz do 8,5 GHz CMC 0,71 %\n10 % do 150 % 8,5 GHz do 12,5 GHz CMC 0,85 %\n10 % do 150 % 12,5 GHz do 18,0 GHz CMC 0,91 %\n10 % do 150 % 18,0 GHz do 26,5 GHz CMC 1,7 %\n10 % do 150 % 26,5 GHz do 40 GHz CMC 2,5 %\n10 % do 150 % 40 GHz do 50 GHz CMC 3,3 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/33 Czujniki mocy\n- wspolczynnik kalibracji Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\n10 % do 150 % 9 kHz do 300 MHz CMC 0,56 %\n10 % do 150 % 300 MHz do 8,5 GHz CMC 0,71 %\n10 % do 150 % 8,5 GHz do 12,5 GHz CMC 0,85 %\n10 % do 150 % 12,5 GHz do 18,0 GHz CMC 0,91 %\n10 % do 150 % 18,0 GHz do 26,5 GHz CMC 1,7 %\n10 % do 150 % 26,5 GHz do 40 GHz CMC 2,5 %\n10 % do 150 % 40 GHz do 50 GHz CMC 3,3 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/33","search_en":"Power sensors - calibration factor Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) 10 % to 150 % 10 % to 150 % 10 % to 150 % 10 % to 150 % 10 % to 150 % 10 % to 150 % 10 % to 150 % LMEEiO/33","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":51,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"10 % bis 150 %","range":"9 kHz to 300 MHz","cmc":"0,56 %"},{"name":"10 % bis 150 %","range":"300 MHz to 8,5 GHz","cmc":"0,71 %"},{"name":"10 % bis 150 %","range":"8,5 GHz to 12,5 GHz","cmc":"0,85 %"},{"name":"10 % bis 150 %","range":"12,5 GHz to 18,0 GHz","cmc":"0,91 %"},{"name":"10 % bis 150 %","range":"18,0 GHz to 26,5 GHz","cmc":"1,7 %"},{"name":"10 % bis 150 %","range":"26,5 GHz to 40 GHz","cmc":"2,5 %"},{"name":"10 % bis 150 %","range":"40 GHz to 50 GHz","cmc":"3,3 %"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Leistungssensoren - Kalibrierfaktor Kalibrierung — elektrische HF-Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 10 % bis 150 % 10 % bis 150 % 10 % bis 150 % 10 % bis 150 % 10 % bis 150 % 10 % bis 150 % 10 % bis 150 % LMEEiO/33","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Leistungssensoren\n- Kalibrierfaktor","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"10 % 至 150 %","range":"9 kHz to 300 MHz","cmc":"0,56 %"},{"name":"10 % 至 150 %","range":"300 MHz to 8,5 GHz","cmc":"0,71 %"},{"name":"10 % 至 150 %","range":"8,5 GHz to 12,5 GHz","cmc":"0,85 %"},{"name":"10 % 至 150 %","range":"12,5 GHz to 18,0 GHz","cmc":"0,91 %"},{"name":"10 % 至 150 %","range":"18,0 GHz to 26,5 GHz","cmc":"1,7 %"},{"name":"10 % 至 150 %","range":"26,5 GHz to 40 GHz","cmc":"2,5 %"},{"name":"10 % 至 150 %","range":"40 GHz to 50 GHz","cmc":"3,3 %"}],"regulatory_area_zh":"射频电学量","search_zh":"功率传感器 - 校准因子 校准 — 射频电学量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 10 % 至 150 % 10 % 至 150 % 10 % 至 150 % 10 % 至 150 % 10 % 至 150 % 10 % 至 150 % 10 % 至 150 % LMEEiO/33","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"功率传感器\n- 校准因子","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"10 % až 150 %","range":"9 kHz to 300 MHz","cmc":"0,56 %"},{"name":"10 % až 150 %","range":"300 MHz to 8,5 GHz","cmc":"0,71 %"},{"name":"10 % až 150 %","range":"8,5 GHz to 12,5 GHz","cmc":"0,85 %"},{"name":"10 % až 150 %","range":"12,5 GHz to 18,0 GHz","cmc":"0,91 %"},{"name":"10 % až 150 %","range":"18,0 GHz to 26,5 GHz","cmc":"1,7 %"},{"name":"10 % až 150 %","range":"26,5 GHz to 40 GHz","cmc":"2,5 %"},{"name":"10 % až 150 %","range":"40 GHz to 50 GHz","cmc":"3,3 %"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Čidla výkonu - kalibrační činitel Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 10 % až 150 % 10 % až 150 % 10 % až 150 % 10 % až 150 % 10 % až 150 % 10 % až 150 % 10 % až 150 % LMEEiO/33","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Čidla výkonu\n- kalibrační činitel"},{"_id":"c1b3d38b330b9aaa36764924","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki częstotliwości\nCzujniki mocy\nObciążenia stałe (terminatory, oporniki)\nTłumiki stałe\nTłumiki regulowane\nFiltry\nSprzęgacze kierunkowe\nPrzełączniki\nAnalizatory systemów antenowych i kablowych\nOdbiorniki pomiarowe\nWzmacniacze\n- współczynnik odbicia S11 / S22","test_object_en":"Frequency meters\nPower sensors\nFixed loads (terminations, resistors)\nFixed attenuators\nVariable attenuators\nFilters\nDirectional couplers\nSwitches\nAntenna and cable system analysers\nMeasuring receivers\nAmplifiers\n- reflection coefficient S11 / S22","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"9 kHz do 50 GHz","range":"0,0 do 1,0","cmc":"Matryca CMC na nast. str."},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0","range":"9 kHz do 300 kHz","cmc":"0,0047"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0","range":"300 kHz do 10 MHz","cmc":"0,0053"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0","range":"10 MHz do 500 MHz","cmc":"0,0073"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0","range":"500 MHz do 2 GHz","cmc":"0,0058"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0","range":"2 GHz do 10 GHz","cmc":"0,0075"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0","range":"10 GHz do 18 GHz","cmc":"0,012"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2","range":"9 kHz do 300 kHz","cmc":"0,0062"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2","range":"300 kHz do 10 MHz","cmc":"0,0072"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2","range":"10 MHz do 500 MHz","cmc":"0,0089"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2","range":"500 MHz do 2 GHz","cmc":"0,0075"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2","range":"2 GHz do 10 GHz","cmc":"0,0094"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2","range":"10 GHz do 18 GHz","cmc":"0,015"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6","range":"9 kHz do 300 kHz","cmc":"0,0096"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6","range":"300 kHz do 10 MHz","cmc":"0,014"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6","range":"10 MHz do 500 MHz","cmc":"0,015"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6","range":"500 MHz do 2 GHz","cmc":"0,013"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6","range":"2 GHz do 10 GHz","cmc":"0,016"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6","range":"10 GHz do 18 GHz","cmc":"0,026"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0","range":"9 kHz do 300 kHz","cmc":"0,015"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0","range":"300 kHz do 10 MHz","cmc":"0,024"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0","range":"10 MHz do 500 MHz","cmc":"0,026"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0","range":"500 MHz do 2 GHz","cmc":"0,021"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0","range":"2 GHz do 10 GHz","cmc":"0,027"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0","range":"10 GHz do 18 GHz","cmc":"0,045"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0","range":"9 kHz do 300 kHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0","range":"300 kHz do 10 MHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0","range":"10 MHz do 500 MHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0","range":"500 MHz do 2 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0","range":"2 GHz do 10 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0","range":"10 GHz do 18 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2","range":"9 kHz do 300 kHz","cmc":"1,8°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2","range":"300 kHz do 10 MHz","cmc":"2,1°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2","range":"10 MHz do 500 MHz","cmc":"2,6°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2","range":"500 MHz do 2 GHz","cmc":"2,2°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2","range":"2 GHz do 10 GHz","cmc":"2,5°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2","range":"10 GHz do 18 GHz","cmc":"4,2°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6","range":"9 kHz do 300 kHz","cmc":"0,91°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6","range":"300 kHz do 10 MHz","cmc":"1,3°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6","range":"10 MHz do 500 MHz","cmc":"1,5°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6","range":"500 MHz do 2 GHz","cmc":"1,2°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6","range":"2 GHz do 10 GHz","cmc":"1,5°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6","range":"10 GHz do 18 GHz","cmc":"2,4°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0","range":"9 kHz do 300 kHz","cmc":"0,82°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0","range":"300 kHz do 10 MHz","cmc":"1,4°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0","range":"10 MHz do 500 MHz","cmc":"1,5°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0","range":"500 MHz do 2 GHz","cmc":"1,2°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0","range":"2 GHz do 10 GHz","cmc":"1,5°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0","range":"10 GHz do 18 GHz","cmc":"2,6°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,0","range":"9 kHz do 30 kHz","cmc":"0,0063"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,0","range":"30 kHz do 1,3 GHz","cmc":"0,0063"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,0","range":"1,3 GHz do 3 GHz","cmc":"0,011"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,2","range":"9 kHz do 30 kHz","cmc":"0,0079"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,2","range":"30 kHz do 1,3 GHz","cmc":"0,0078"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,2","range":"1,3 GHz do 3 GHz","cmc":"0,014"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,6","range":"9 kHz do 30 kHz","cmc":"0,013"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,6","range":"30 kHz do 1,3 GHz","cmc":"0,012"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,6","range":"1,3 GHz do 3 GHz","cmc":"0,025"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 1,0","range":"9 kHz do 30 kHz","cmc":"0,019"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 1,0","range":"30 kHz do 1,3 GHz","cmc":"0,018"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 1,0","range":"1,3 GHz do 3 GHz","cmc":"0,043"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,0","range":"9 kHz do 30 kHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,0","range":"30 kHz do 1,3 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,0","range":"1,3 GHz do 3 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,2","range":"9 kHz do 30 kHz","cmc":"2,3°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,2","range":"30 kHz do 1,3 GHz","cmc":"2,3°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,2","range":"1,3 GHz do 3 GHz","cmc":"3,9°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,6","range":"9 kHz do 30 kHz","cmc":"1,2°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,6","range":"30 kHz do 1,3 GHz","cmc":"1,2°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,6","range":"1,3 GHz do 3 GHz","cmc":"2,4°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 1,0","range":"9 kHz do 30 kHz","cmc":"1,1°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 1,0","range":"30 kHz do 1,3 GHz","cmc":"1,1°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 1,0","range":"1,3 GHz do 3 GHz","cmc":"2,5°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0","range":"9 kHz do 10 MHz","cmc":"0,012"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0","range":"10 MHz do 45 MHz","cmc":"0,0073"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0","range":"45 MHz do 500 MHz","cmc":"0,0073"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0","range":"500 MHz do 2 GHz","cmc":"0,0025"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0","range":"2 GHz do 10 GHz","cmc":"0,0033"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0","range":"10 GHz do 20 GHz","cmc":"0,0061"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0","range":"20 GHz do 26,5 GHz","cmc":"0,0096"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2","range":"9 kHz do 10 MHz","cmc":"0,014"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2","range":"10 MHz do 45 MHz","cmc":"0,011"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2","range":"45 MHz do 500 MHz","cmc":"0,0096"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2","range":"500 MHz do 2 GHz","cmc":"0,0037"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2","range":"2 GHz do 10 GHz","cmc":"0,0049"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2","range":"10 GHz do 20 GHz","cmc":"0,0081"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2","range":"20 GHz do 26,5 GHz","cmc":"0,013"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6","range":"9 kHz do 10 MHz","cmc":"0,022"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6","range":"10 MHz do 45 MHz","cmc":"0,022"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6","range":"45 MHz do 500 MHz","cmc":"0,017"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6","range":"500 MHz do 2 GHz","cmc":"0,0073"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6","range":"2 GHz do 10 GHz","cmc":"0,0099"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6","range":"10 GHz do 20 GHz","cmc":"0,014"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6","range":"20 GHz do 26,5 GHz","cmc":"0,021"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0","range":"9 kHz do 10 MHz","cmc":"0,036"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0","range":"10 MHz do 45 MHz","cmc":"0,036"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0","range":"45 MHz do 500 MHz","cmc":"0,028"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0","range":"500 MHz do 2 GHz","cmc":"0,013"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0","range":"2 GHz do 10 GHz","cmc":"0,017"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0","range":"10 GHz do 20 GHz","cmc":"0,023"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0","range":"20 GHz do 26,5 GHz","cmc":"0,033"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0","range":"9 kHz do 10 MHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0","range":"10 MHz do 45 MHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0","range":"45 MHz do 500 MHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0","range":"500 MHz do 2 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0","range":"2 GHz do 10 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0","range":"10 GHz do 20 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0","range":"20 GHz do 26,5 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2","range":"9 kHz do 10 MHz","cmc":"4,0°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2","range":"10 MHz do 45 MHz","cmc":"3,1°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2","range":"45 MHz do 500 MHz","cmc":"2,8°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2","range":"500 MHz do 2 GHz","cmc":"1,1°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2","range":"2 GHz do 10 GHz","cmc":"1,5°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2","range":"10 GHz do 20 GHz","cmc":"2,3°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2","range":"20 GHz do 26,5 GHz","cmc":"3,5°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6","range":"9 kHz do 10 MHz","cmc":"2,1°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6","range":"10 MHz do 45 MHz","cmc":"2,1°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6","range":"45 MHz do 500 MHz","cmc":"1,6°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6","range":"500 MHz do 2 GHz","cmc":"0,70°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6","range":"2 GHz do 10 GHz","cmc":"0,95°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6","range":"10 GHz do 20 GHz","cmc":"1,4°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6","range":"20 GHz do 26,5 GHz","cmc":"2,0°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0","range":"9 kHz do 10 MHz","cmc":"2,1°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0","range":"10 MHz do 45 MHz","cmc":"2,1°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0","range":"45 MHz do 500 MHz","cmc":"1,6°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0","range":"500 MHz do 2 GHz","cmc":"0,73°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0","range":"2 GHz do 10 GHz","cmc":"0,98°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0","range":"10 GHz do 20 GHz","cmc":"1,3°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0","range":"20 GHz do 26,5 GHz","cmc":"1,9°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0","range":"9 kHz do 45 MHz","cmc":"0,015"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0","range":"45 MHz do 2 GHz","cmc":"0,0042"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0","range":"2 GHz do 10 GHz","cmc":"0,0055"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0","range":"10 GHz do 20 GHz","cmc":"0,0084"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0","range":"20 GHz do 40 GHz","cmc":"0,014"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0","range":"40 GHz do 50 GHz","cmc":"0,013"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2","range":"9 kHz do 45 MHz","cmc":"0,017"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2","range":"45 MHz do 2 GHz","cmc":"0,0058"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2","range":"2 GHz do 10 GHz","cmc":"0,0076"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2","range":"10 GHz do 20 GHz","cmc":"0,012"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2","range":"20 GHz do 40 GHz","cmc":"0,017"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2","range":"40 GHz do 50 GHz","cmc":"0,017"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6","range":"9 kHz do 45 MHz","cmc":"0,025"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6","range":"45 MHz do 2 GHz","cmc":"0,011"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6","range":"2 GHz do 10 GHz","cmc":"0,015"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6","range":"10 GHz do 20 GHz","cmc":"0,021"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6","range":"20 GHz do 40 GHz","cmc":"0,029"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6","range":"40 GHz do 50 GHz","cmc":"0,030"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0","range":"9 kHz do 45 MHz","cmc":"0,037"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0","range":"45 MHz do 2 GHz","cmc":"0,017"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0","range":"2 GHz do 10 GHz","cmc":"0,024"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0","range":"10 GHz do 20 GHz","cmc":"0,037"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0","range":"20 GHz do 40 GHz","cmc":"0,049"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0","range":"40 GHz do 50 GHz","cmc":"0,051"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0","range":"9 kHz do 45 MHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0","range":"45 MHz do 2 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0","range":"2 GHz do 10 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0","range":"10 GHz do 20 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0","range":"20 GHz do 40 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0","range":"40 GHz do 50 GHz","cmc":"180°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2","range":"9 kHz do 45 MHz","cmc":"4,8°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2","range":"45 MHz do 2 GHz","cmc":"1,7°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2","range":"2 GHz do 10 GHz","cmc":"2,2°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2","range":"10 GHz do 20 GHz","cmc":"3,2°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2","range":"20 GHz do 40 GHz","cmc":"4,8°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2","range":"40 GHz do 50 GHz","cmc":"8,0°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6","range":"9 kHz do 45 MHz","cmc":"2,4°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6","range":"45 MHz do 2 GHz","cmc":"0,97°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6","range":"2 GHz do 10 GHz","cmc":"1,4°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6","range":"10 GHz do 20 GHz","cmc":"2,1°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6","range":"20 GHz do 40 GHz","cmc":"2,8°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6","range":"40 GHz do 50 GHz","cmc":"4,3°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0","range":"9 kHz do 45 MHz","cmc":"2,1°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0","range":"45 MHz do 2 GHz","cmc":"0,96°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0","range":"2 GHz do 10 GHz","cmc":"1,4°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0","range":"10 GHz do 20 GHz","cmc":"2,2°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0","range":"20 GHz do 40 GHz","cmc":"2,9°"},{"name":"Matryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0","range":"40 GHz do 50 GHz","cmc":"4,3°"}],"parameters_en":[{"name":"9 kHz to 50 GHz","range":"0,0 to 1,0","cmc":"CMC matrix on the following pages"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0","range":"9 kHz to 300 kHz","cmc":"0,0047"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0","range":"300 kHz to 10 MHz","cmc":"0,0053"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0","range":"10 MHz to 500 MHz","cmc":"0,0073"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"0,0058"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"0,0075"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0","range":"10 GHz to 18 GHz","cmc":"0,012"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2","range":"9 kHz to 300 kHz","cmc":"0,0062"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2","range":"300 kHz to 10 MHz","cmc":"0,0072"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2","range":"10 MHz to 500 MHz","cmc":"0,0089"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"0,0075"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"0,0094"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2","range":"10 GHz to 18 GHz","cmc":"0,015"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6","range":"9 kHz to 300 kHz","cmc":"0,0096"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6","range":"300 kHz to 10 MHz","cmc":"0,014"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6","range":"10 MHz to 500 MHz","cmc":"0,015"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"0,013"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,016"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6","range":"10 GHz to 18 GHz","cmc":"0,026"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0","range":"9 kHz to 300 kHz","cmc":"0,015"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0","range":"300 kHz to 10 MHz","cmc":"0,024"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0","range":"10 MHz to 500 MHz","cmc":"0,026"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"0,021"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,027"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0","range":"10 GHz to 18 GHz","cmc":"0,045"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0","range":"9 kHz to 300 kHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0","range":"300 kHz to 10 MHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0","range":"10 MHz to 500 MHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0","range":"10 GHz to 18 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2","range":"9 kHz to 300 kHz","cmc":"1,8°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2","range":"300 kHz to 10 MHz","cmc":"2,1°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2","range":"10 MHz to 500 MHz","cmc":"2,6°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"2,2°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"2,5°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2","range":"10 GHz to 18 GHz","cmc":"4,2°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6","range":"9 kHz to 300 kHz","cmc":"0,91°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6","range":"300 kHz to 10 MHz","cmc":"1,3°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6","range":"10 MHz to 500 MHz","cmc":"1,5°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"1,2°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"1,5°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6","range":"10 GHz to 18 GHz","cmc":"2,4°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0","range":"9 kHz to 300 kHz","cmc":"0,82°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0","range":"300 kHz to 10 MHz","cmc":"1,4°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0","range":"10 MHz to 500 MHz","cmc":"1,5°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"1,2°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"1,5°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0","range":"10 GHz to 18 GHz","cmc":"2,6°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,0","range":"9 kHz to 30 kHz","cmc":"0,0063"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,0","range":"30 kHz to 1,3 GHz","cmc":"0,0063"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,0","range":"1,3 GHz to 3 GHz","cmc":"0,011"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,2","range":"9 kHz to 30 kHz","cmc":"0,0079"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,2","range":"30 kHz to 1,3 GHz","cmc":"0,0078"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,2","range":"1,3 GHz to 3 GHz","cmc":"0,014"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,6","range":"9 kHz to 30 kHz","cmc":"0,013"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,6","range":"30 kHz to 1,3 GHz","cmc":"0,012"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,6","range":"1,3 GHz to 3 GHz","cmc":"0,025"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 1,0","range":"9 kHz to 30 kHz","cmc":"0,019"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 1,0","range":"30 kHz to 1,3 GHz","cmc":"0,018"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 1,0","range":"1,3 GHz to 3 GHz","cmc":"0,043"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,0","range":"9 kHz to 30 kHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,0","range":"30 kHz to 1,3 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,0","range":"1,3 GHz to 3 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,2","range":"9 kHz to 30 kHz","cmc":"2,3°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,2","range":"30 kHz to 1,3 GHz","cmc":"2,3°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,2","range":"1,3 GHz to 3 GHz","cmc":"3,9°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,6","range":"9 kHz to 30 kHz","cmc":"1,2°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,6","range":"30 kHz to 1,3 GHz","cmc":"1,2°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,6","range":"1,3 GHz to 3 GHz","cmc":"2,4°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 1,0","range":"9 kHz to 30 kHz","cmc":"1,1°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 1,0","range":"30 kHz to 1,3 GHz","cmc":"1,1°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 1,0","range":"1,3 GHz to 3 GHz","cmc":"2,5°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0","range":"9 kHz to 10 MHz","cmc":"0,012"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0","range":"10 MHz to 45 MHz","cmc":"0,0073"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0","range":"45 MHz to 500 MHz","cmc":"0,0073"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"0,0025"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"0,0033"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0","range":"10 GHz to 20 GHz","cmc":"0,0061"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0","range":"20 GHz to 26,5 GHz","cmc":"0,0096"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2","range":"9 kHz to 10 MHz","cmc":"0,014"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2","range":"10 MHz to 45 MHz","cmc":"0,011"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2","range":"45 MHz to 500 MHz","cmc":"0,0096"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"0,0037"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"0,0049"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2","range":"10 GHz to 20 GHz","cmc":"0,0081"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2","range":"20 GHz to 26,5 GHz","cmc":"0,013"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6","range":"9 kHz to 10 MHz","cmc":"0,022"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6","range":"10 MHz to 45 MHz","cmc":"0,022"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6","range":"45 MHz to 500 MHz","cmc":"0,017"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"0,0073"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,0099"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6","range":"10 GHz to 20 GHz","cmc":"0,014"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6","range":"20 GHz to 26,5 GHz","cmc":"0,021"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0","range":"9 kHz to 10 MHz","cmc":"0,036"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0","range":"10 MHz to 45 MHz","cmc":"0,036"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0","range":"45 MHz to 500 MHz","cmc":"0,028"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"0,013"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,017"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0","range":"10 GHz to 20 GHz","cmc":"0,023"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0","range":"20 GHz to 26,5 GHz","cmc":"0,033"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0","range":"9 kHz to 10 MHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0","range":"10 MHz to 45 MHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0","range":"45 MHz to 500 MHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0","range":"10 GHz to 20 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0","range":"20 GHz to 26,5 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2","range":"9 kHz to 10 MHz","cmc":"4,0°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2","range":"10 MHz to 45 MHz","cmc":"3,1°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2","range":"45 MHz to 500 MHz","cmc":"2,8°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"1,1°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"1,5°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2","range":"10 GHz to 20 GHz","cmc":"2,3°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2","range":"20 GHz to 26,5 GHz","cmc":"3,5°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6","range":"9 kHz to 10 MHz","cmc":"2,1°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6","range":"10 MHz to 45 MHz","cmc":"2,1°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6","range":"45 MHz to 500 MHz","cmc":"1,6°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"0,70°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,95°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6","range":"10 GHz to 20 GHz","cmc":"1,4°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6","range":"20 GHz to 26,5 GHz","cmc":"2,0°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0","range":"9 kHz to 10 MHz","cmc":"2,1°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0","range":"10 MHz to 45 MHz","cmc":"2,1°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0","range":"45 MHz to 500 MHz","cmc":"1,6°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"0,73°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,98°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0","range":"10 GHz to 20 GHz","cmc":"1,3°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0","range":"20 GHz to 26,5 GHz","cmc":"1,9°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0","range":"9 kHz to 45 MHz","cmc":"0,015"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0","range":"45 MHz to 2 GHz","cmc":"0,0042"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"0,0055"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0","range":"10 GHz to 20 GHz","cmc":"0,0084"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0","range":"20 GHz to 40 GHz","cmc":"0,014"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0","range":"40 GHz to 50 GHz","cmc":"0,013"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2","range":"9 kHz to 45 MHz","cmc":"0,017"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2","range":"45 MHz to 2 GHz","cmc":"0,0058"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"0,0076"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2","range":"10 GHz to 20 GHz","cmc":"0,012"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2","range":"20 GHz to 40 GHz","cmc":"0,017"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2","range":"40 GHz to 50 GHz","cmc":"0,017"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6","range":"9 kHz to 45 MHz","cmc":"0,025"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6","range":"45 MHz to 2 GHz","cmc":"0,011"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,015"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6","range":"10 GHz to 20 GHz","cmc":"0,021"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6","range":"20 GHz to 40 GHz","cmc":"0,029"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6","range":"40 GHz to 50 GHz","cmc":"0,030"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0","range":"9 kHz to 45 MHz","cmc":"0,037"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0","range":"45 MHz to 2 GHz","cmc":"0,017"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,024"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0","range":"10 GHz to 20 GHz","cmc":"0,037"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0","range":"20 GHz to 40 GHz","cmc":"0,049"},{"name":"CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0","range":"40 GHz to 50 GHz","cmc":"0,051"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0","range":"9 kHz to 45 MHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0","range":"45 MHz to 2 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0","range":"10 GHz to 20 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0","range":"20 GHz to 40 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0","range":"40 GHz to 50 GHz","cmc":"180°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2","range":"9 kHz to 45 MHz","cmc":"4,8°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2","range":"45 MHz to 2 GHz","cmc":"1,7°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"2,2°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2","range":"10 GHz to 20 GHz","cmc":"3,2°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2","range":"20 GHz to 40 GHz","cmc":"4,8°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2","range":"40 GHz to 50 GHz","cmc":"8,0°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6","range":"9 kHz to 45 MHz","cmc":"2,4°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6","range":"45 MHz to 2 GHz","cmc":"0,97°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"1,4°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6","range":"10 GHz to 20 GHz","cmc":"2,1°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6","range":"20 GHz to 40 GHz","cmc":"2,8°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6","range":"40 GHz to 50 GHz","cmc":"4,3°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0","range":"9 kHz to 45 MHz","cmc":"2,1°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0","range":"45 MHz to 2 GHz","cmc":"0,96°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"1,4°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0","range":"10 GHz to 20 GHz","cmc":"2,2°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0","range":"20 GHz to 40 GHz","cmc":"2,9°"},{"name":"CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0","range":"40 GHz to 50 GHz","cmc":"4,3°"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\n9 kHz do 50 GHz 0,0 do 1,0 CMC Matryca CMC na nast. str.\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0 9 kHz do 300 kHz CMC 0,0047\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0 300 kHz do 10 MHz CMC 0,0053\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0 10 MHz do 500 MHz CMC 0,0073\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0 500 MHz do 2 GHz CMC 0,0058\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 0,0075\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0 10 GHz do 18 GHz CMC 0,012\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2 9 kHz do 300 kHz CMC 0,0062\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2 300 kHz do 10 MHz CMC 0,0072\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2 10 MHz do 500 MHz CMC 0,0089\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2 500 MHz do 2 GHz CMC 0,0075\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 0,0094\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2 10 GHz do 18 GHz CMC 0,015\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6 9 kHz do 300 kHz CMC 0,0096\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6 300 kHz do 10 MHz CMC 0,014\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6 10 MHz do 500 MHz CMC 0,015\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6 500 MHz do 2 GHz CMC 0,013\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 0,016\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6 10 GHz do 18 GHz CMC 0,026\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0 9 kHz do 300 kHz CMC 0,015\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0 300 kHz do 10 MHz CMC 0,024\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0 10 MHz do 500 MHz CMC 0,026\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0 500 MHz do 2 GHz CMC 0,021\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 0,027\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0 10 GHz do 18 GHz CMC 0,045\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0 9 kHz do 300 kHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0 300 kHz do 10 MHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0 10 MHz do 500 MHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0 500 MHz do 2 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0 10 GHz do 18 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2 9 kHz do 300 kHz CMC 1,8°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2 300 kHz do 10 MHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2 10 MHz do 500 MHz CMC 2,6°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2 500 MHz do 2 GHz CMC 2,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 2,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2 10 GHz do 18 GHz CMC 4,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6 9 kHz do 300 kHz CMC 0,91°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6 300 kHz do 10 MHz CMC 1,3°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6 10 MHz do 500 MHz CMC 1,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6 500 MHz do 2 GHz CMC 1,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 1,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6 10 GHz do 18 GHz CMC 2,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0 9 kHz do 300 kHz CMC 0,82°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0 300 kHz do 10 MHz CMC 1,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0 10 MHz do 500 MHz CMC 1,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0 500 MHz do 2 GHz CMC 1,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 1,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0 10 GHz do 18 GHz CMC 2,6°\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,0 9 kHz do 30 kHz CMC 0,0063\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,0 30 kHz do 1,3 GHz CMC 0,0063\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,0 1,3 GHz do 3 GHz CMC 0,011\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,2 9 kHz do 30 kHz CMC 0,0079\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,2 30 kHz do 1,3 GHz CMC 0,0078\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,2 1,3 GHz do 3 GHz CMC 0,014\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,6 9 kHz do 30 kHz CMC 0,013\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,6 30 kHz do 1,3 GHz CMC 0,012\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,6 1,3 GHz do 3 GHz CMC 0,025\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 1,0 9 kHz do 30 kHz CMC 0,019\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 1,0 30 kHz do 1,3 GHz CMC 0,018\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 1,0 1,3 GHz do 3 GHz CMC 0,043\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,0 9 kHz do 30 kHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,0 30 kHz do 1,3 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,0 1,3 GHz do 3 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,2 9 kHz do 30 kHz CMC 2,3°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,2 30 kHz do 1,3 GHz CMC 2,3°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,2 1,3 GHz do 3 GHz CMC 3,9°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,6 9 kHz do 30 kHz CMC 1,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,6 30 kHz do 1,3 GHz CMC 1,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,6 1,3 GHz do 3 GHz CMC 2,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 1,0 9 kHz do 30 kHz CMC 1,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 1,0 30 kHz do 1,3 GHz CMC 1,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 1,0 1,3 GHz do 3 GHz CMC 2,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 9 kHz do 10 MHz CMC 0,012\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 10 MHz do 45 MHz CMC 0,0073\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 45 MHz do 500 MHz CMC 0,0073\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 500 MHz do 2 GHz CMC 0,0025\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 0,0033\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 10 GHz do 20 GHz CMC 0,0061\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 20 GHz do 26,5 GHz CMC 0,0096\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 9 kHz do 10 MHz CMC 0,014\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 10 MHz do 45 MHz CMC 0,011\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 45 MHz do 500 MHz CMC 0,0096\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 500 MHz do 2 GHz CMC 0,0037\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 0,0049\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 10 GHz do 20 GHz CMC 0,0081\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 20 GHz do 26,5 GHz CMC 0,013\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 9 kHz do 10 MHz CMC 0,022\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 10 MHz do 45 MHz CMC 0,022\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 45 MHz do 500 MHz CMC 0,017\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 500 MHz do 2 GHz CMC 0,0073\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 0,0099\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 10 GHz do 20 GHz CMC 0,014\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 20 GHz do 26,5 GHz CMC 0,021\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 9 kHz do 10 MHz CMC 0,036\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 10 MHz do 45 MHz CMC 0,036\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 45 MHz do 500 MHz CMC 0,028\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 500 MHz do 2 GHz CMC 0,013\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 0,017\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 10 GHz do 20 GHz CMC 0,023\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 20 GHz do 26,5 GHz CMC 0,033\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 9 kHz do 10 MHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 10 MHz do 45 MHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 45 MHz do 500 MHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 500 MHz do 2 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 10 GHz do 20 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 20 GHz do 26,5 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 9 kHz do 10 MHz CMC 4,0°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 10 MHz do 45 MHz CMC 3,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 45 MHz do 500 MHz CMC 2,8°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 500 MHz do 2 GHz CMC 1,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 1,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 10 GHz do 20 GHz CMC 2,3°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 20 GHz do 26,5 GHz CMC 3,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 9 kHz do 10 MHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 10 MHz do 45 MHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 45 MHz do 500 MHz CMC 1,6°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 500 MHz do 2 GHz CMC 0,70°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 0,95°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 10 GHz do 20 GHz CMC 1,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 20 GHz do 26,5 GHz CMC 2,0°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 9 kHz do 10 MHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 10 MHz do 45 MHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 45 MHz do 500 MHz CMC 1,6°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 500 MHz do 2 GHz CMC 0,73°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 0,98°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 10 GHz do 20 GHz CMC 1,3°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 20 GHz do 26,5 GHz CMC 1,9°\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0 9 kHz do 45 MHz CMC 0,015\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0 45 MHz do 2 GHz CMC 0,0042\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 0,0055\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0 10 GHz do 20 GHz CMC 0,0084\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0 20 GHz do 40 GHz CMC 0,014\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0 40 GHz do 50 GHz CMC 0,013\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2 9 kHz do 45 MHz CMC 0,017\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2 45 MHz do 2 GHz CMC 0,0058\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 0,0076\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2 10 GHz do 20 GHz CMC 0,012\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2 20 GHz do 40 GHz CMC 0,017\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2 40 GHz do 50 GHz CMC 0,017\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6 9 kHz do 45 MHz CMC 0,025\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6 45 MHz do 2 GHz CMC 0,011\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 0,015\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6 10 GHz do 20 GHz CMC 0,021\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6 20 GHz do 40 GHz CMC 0,029\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6 40 GHz do 50 GHz CMC 0,030\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0 9 kHz do 45 MHz CMC 0,037\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0 45 MHz do 2 GHz CMC 0,017\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 0,024\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0 10 GHz do 20 GHz CMC 0,037\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0 20 GHz do 40 GHz CMC 0,049\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0 40 GHz do 50 GHz CMC 0,051\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0 9 kHz do 45 MHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0 45 MHz do 2 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0 10 GHz do 20 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0 20 GHz do 40 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0 40 GHz do 50 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2 9 kHz do 45 MHz CMC 4,8°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2 45 MHz do 2 GHz CMC 1,7°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 2,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2 10 GHz do 20 GHz CMC 3,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2 20 GHz do 40 GHz CMC 4,8°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2 40 GHz do 50 GHz CMC 8,0°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6 9 kHz do 45 MHz CMC 2,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6 45 MHz do 2 GHz CMC 0,97°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 1,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6 10 GHz do 20 GHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6 20 GHz do 40 GHz CMC 2,8°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6 40 GHz do 50 GHz CMC 4,3°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0 9 kHz do 45 MHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0 45 MHz do 2 GHz CMC 0,96°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 1,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0 10 GHz do 20 GHz CMC 2,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0 20 GHz do 40 GHz CMC 2,9°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0 40 GHz do 50 GHz CMC 4,3°\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/34\nLMEEiO/48","norm_bases":["LMEEiO/34","LMEEiO/48"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki częstotliwości\nCzujniki mocy\nObciążenia stałe (terminatory, oporniki)\nTłumiki stałe\nTłumiki regulowane\nFiltry\nSprzęgacze kierunkowe\nPrzełączniki\nAnalizatory systemów antenowych i kablowych\nOdbiorniki pomiarowe\nWzmacniacze\n- współczynnik odbicia S11 / S22 Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\n9 kHz do 50 GHz 0,0 do 1,0 CMC Matryca CMC na nast. str.\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0 9 kHz do 300 kHz CMC 0,0047\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0 300 kHz do 10 MHz CMC 0,0053\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0 10 MHz do 500 MHz CMC 0,0073\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0 500 MHz do 2 GHz CMC 0,0058\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 0,0075\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,0 10 GHz do 18 GHz CMC 0,012\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2 9 kHz do 300 kHz CMC 0,0062\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2 300 kHz do 10 MHz CMC 0,0072\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2 10 MHz do 500 MHz CMC 0,0089\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2 500 MHz do 2 GHz CMC 0,0075\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 0,0094\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,2 10 GHz do 18 GHz CMC 0,015\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6 9 kHz do 300 kHz CMC 0,0096\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6 300 kHz do 10 MHz CMC 0,014\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6 10 MHz do 500 MHz CMC 0,015\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6 500 MHz do 2 GHz CMC 0,013\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 0,016\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 0,6 10 GHz do 18 GHz CMC 0,026\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0 9 kHz do 300 kHz CMC 0,015\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0 300 kHz do 10 MHz CMC 0,024\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0 10 MHz do 500 MHz CMC 0,026\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0 500 MHz do 2 GHz CMC 0,021\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 0,027\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 50 Ω); S11 / S22 = 1,0 10 GHz do 18 GHz CMC 0,045\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0 9 kHz do 300 kHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0 300 kHz do 10 MHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0 10 MHz do 500 MHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0 500 MHz do 2 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,0 10 GHz do 18 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2 9 kHz do 300 kHz CMC 1,8°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2 300 kHz do 10 MHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2 10 MHz do 500 MHz CMC 2,6°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2 500 MHz do 2 GHz CMC 2,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 2,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,2 10 GHz do 18 GHz CMC 4,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6 9 kHz do 300 kHz CMC 0,91°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6 300 kHz do 10 MHz CMC 1,3°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6 10 MHz do 500 MHz CMC 1,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6 500 MHz do 2 GHz CMC 1,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 1,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 0,6 10 GHz do 18 GHz CMC 2,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0 9 kHz do 300 kHz CMC 0,82°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0 300 kHz do 10 MHz CMC 1,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0 10 MHz do 500 MHz CMC 1,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0 500 MHz do 2 GHz CMC 1,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 1,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 50 Ω); S11 / S22 = 1,0 10 GHz do 18 GHz CMC 2,6°\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,0 9 kHz do 30 kHz CMC 0,0063\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,0 30 kHz do 1,3 GHz CMC 0,0063\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,0 1,3 GHz do 3 GHz CMC 0,011\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,2 9 kHz do 30 kHz CMC 0,0079\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,2 30 kHz do 1,3 GHz CMC 0,0078\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,2 1,3 GHz do 3 GHz CMC 0,014\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,6 9 kHz do 30 kHz CMC 0,013\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,6 30 kHz do 1,3 GHz CMC 0,012\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 0,6 1,3 GHz do 3 GHz CMC 0,025\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 1,0 9 kHz do 30 kHz CMC 0,019\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 1,0 30 kHz do 1,3 GHz CMC 0,018\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze N 75 Ω); S11 / S22 = 1,0 1,3 GHz do 3 GHz CMC 0,043\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,0 9 kHz do 30 kHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,0 30 kHz do 1,3 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,0 1,3 GHz do 3 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,2 9 kHz do 30 kHz CMC 2,3°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,2 30 kHz do 1,3 GHz CMC 2,3°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,2 1,3 GHz do 3 GHz CMC 3,9°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,6 9 kHz do 30 kHz CMC 1,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,6 30 kHz do 1,3 GHz CMC 1,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 0,6 1,3 GHz do 3 GHz CMC 2,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 1,0 9 kHz do 30 kHz CMC 1,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 1,0 30 kHz do 1,3 GHz CMC 1,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze N 75 Ω); S11 / S22 = 1,0 1,3 GHz do 3 GHz CMC 2,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 9 kHz do 10 MHz CMC 0,012\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 10 MHz do 45 MHz CMC 0,0073\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 45 MHz do 500 MHz CMC 0,0073\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 500 MHz do 2 GHz CMC 0,0025\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 0,0033\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 10 GHz do 20 GHz CMC 0,0061\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,0 20 GHz do 26,5 GHz CMC 0,0096\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 9 kHz do 10 MHz CMC 0,014\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 10 MHz do 45 MHz CMC 0,011\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 45 MHz do 500 MHz CMC 0,0096\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 500 MHz do 2 GHz CMC 0,0037\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 0,0049\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 10 GHz do 20 GHz CMC 0,0081\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,2 20 GHz do 26,5 GHz CMC 0,013\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 9 kHz do 10 MHz CMC 0,022\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 10 MHz do 45 MHz CMC 0,022\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 45 MHz do 500 MHz CMC 0,017\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 500 MHz do 2 GHz CMC 0,0073\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 0,0099\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 10 GHz do 20 GHz CMC 0,014\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 0,6 20 GHz do 26,5 GHz CMC 0,021\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 9 kHz do 10 MHz CMC 0,036\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 10 MHz do 45 MHz CMC 0,036\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 45 MHz do 500 MHz CMC 0,028\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 500 MHz do 2 GHz CMC 0,013\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 0,017\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 10 GHz do 20 GHz CMC 0,023\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 3,5 mm); S11 / S22 = 1,0 20 GHz do 26,5 GHz CMC 0,033\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 9 kHz do 10 MHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 10 MHz do 45 MHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 45 MHz do 500 MHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 500 MHz do 2 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 10 GHz do 20 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,0 20 GHz do 26,5 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 9 kHz do 10 MHz CMC 4,0°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 10 MHz do 45 MHz CMC 3,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 45 MHz do 500 MHz CMC 2,8°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 500 MHz do 2 GHz CMC 1,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 1,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 10 GHz do 20 GHz CMC 2,3°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,2 20 GHz do 26,5 GHz CMC 3,5°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 9 kHz do 10 MHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 10 MHz do 45 MHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 45 MHz do 500 MHz CMC 1,6°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 500 MHz do 2 GHz CMC 0,70°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 0,95°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 10 GHz do 20 GHz CMC 1,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 0,6 20 GHz do 26,5 GHz CMC 2,0°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 9 kHz do 10 MHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 10 MHz do 45 MHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 45 MHz do 500 MHz CMC 1,6°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 500 MHz do 2 GHz CMC 0,73°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 0,98°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 10 GHz do 20 GHz CMC 1,3°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 3,5 mm); S11 / S22 = 1,0 20 GHz do 26,5 GHz CMC 1,9°\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0 9 kHz do 45 MHz CMC 0,015\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0 45 MHz do 2 GHz CMC 0,0042\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 0,0055\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0 10 GHz do 20 GHz CMC 0,0084\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0 20 GHz do 40 GHz CMC 0,014\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,0 40 GHz do 50 GHz CMC 0,013\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2 9 kHz do 45 MHz CMC 0,017\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2 45 MHz do 2 GHz CMC 0,0058\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 0,0076\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2 10 GHz do 20 GHz CMC 0,012\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2 20 GHz do 40 GHz CMC 0,017\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,2 40 GHz do 50 GHz CMC 0,017\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6 9 kHz do 45 MHz CMC 0,025\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6 45 MHz do 2 GHz CMC 0,011\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 0,015\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6 10 GHz do 20 GHz CMC 0,021\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6 20 GHz do 40 GHz CMC 0,029\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 0,6 40 GHz do 50 GHz CMC 0,030\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0 9 kHz do 45 MHz CMC 0,037\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0 45 MHz do 2 GHz CMC 0,017\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 0,024\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0 10 GHz do 20 GHz CMC 0,037\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0 20 GHz do 40 GHz CMC 0,049\nMatryca CMC – współczynnik odbicia S11 / S22 – moduł (złącze 2,4 mm); S11 / S22 = 1,0 40 GHz do 50 GHz CMC 0,051\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0 9 kHz do 45 MHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0 45 MHz do 2 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0 10 GHz do 20 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0 20 GHz do 40 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,0 40 GHz do 50 GHz CMC 180°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2 9 kHz do 45 MHz CMC 4,8°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2 45 MHz do 2 GHz CMC 1,7°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 2,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2 10 GHz do 20 GHz CMC 3,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2 20 GHz do 40 GHz CMC 4,8°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,2 40 GHz do 50 GHz CMC 8,0°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6 9 kHz do 45 MHz CMC 2,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6 45 MHz do 2 GHz CMC 0,97°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 1,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6 10 GHz do 20 GHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6 20 GHz do 40 GHz CMC 2,8°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 0,6 40 GHz do 50 GHz CMC 4,3°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0 9 kHz do 45 MHz CMC 2,1°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0 45 MHz do 2 GHz CMC 0,96°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 1,4°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0 10 GHz do 20 GHz CMC 2,2°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0 20 GHz do 40 GHz CMC 2,9°\nMatryca CMC – współczynnik odbicia S11 / S22 – faza (złącze 2,4 mm); S11 / S22 = 1,0 40 GHz do 50 GHz CMC 4,3°\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/34\nLMEEiO/48 Mierniki czestotliwosci\nCzujniki mocy\nObciazenia stale (terminatory, oporniki)\nTlumiki stale\nTlumiki regulowane\nFiltry\nSprzegacze kierunkowe\nPrzelaczniki\nAnalizatory systemow antenowych i kablowych\nOdbiorniki pomiarowe\nWzmacniacze\n- wspolczynnik odbicia S11 / S22 Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\n9 kHz do 50 GHz 0,0 do 1,0 CMC Matryca CMC na nast. str.\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,0 9 kHz do 300 kHz CMC 0,0047\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,0 300 kHz do 10 MHz CMC 0,0053\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,0 10 MHz do 500 MHz CMC 0,0073\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,0 500 MHz do 2 GHz CMC 0,0058\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 0,0075\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,0 10 GHz do 18 GHz CMC 0,012\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,2 9 kHz do 300 kHz CMC 0,0062\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,2 300 kHz do 10 MHz CMC 0,0072\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,2 10 MHz do 500 MHz CMC 0,0089\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,2 500 MHz do 2 GHz CMC 0,0075\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 0,0094\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,2 10 GHz do 18 GHz CMC 0,015\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,6 9 kHz do 300 kHz CMC 0,0096\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,6 300 kHz do 10 MHz CMC 0,014\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,6 10 MHz do 500 MHz CMC 0,015\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,6 500 MHz do 2 GHz CMC 0,013\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 0,016\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 0,6 10 GHz do 18 GHz CMC 0,026\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 1,0 9 kHz do 300 kHz CMC 0,015\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 1,0 300 kHz do 10 MHz CMC 0,024\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 1,0 10 MHz do 500 MHz CMC 0,026\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 1,0 500 MHz do 2 GHz CMC 0,021\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 0,027\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 50 Ω); S11 / S22 = 1,0 10 GHz do 18 GHz CMC 0,045\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,0 9 kHz do 300 kHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,0 300 kHz do 10 MHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,0 10 MHz do 500 MHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,0 500 MHz do 2 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,0 10 GHz do 18 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,2 9 kHz do 300 kHz CMC 1,8°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,2 300 kHz do 10 MHz CMC 2,1°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,2 10 MHz do 500 MHz CMC 2,6°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,2 500 MHz do 2 GHz CMC 2,2°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 2,5°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,2 10 GHz do 18 GHz CMC 4,2°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,6 9 kHz do 300 kHz CMC 0,91°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,6 300 kHz do 10 MHz CMC 1,3°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,6 10 MHz do 500 MHz CMC 1,5°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,6 500 MHz do 2 GHz CMC 1,2°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 1,5°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 0,6 10 GHz do 18 GHz CMC 2,4°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 1,0 9 kHz do 300 kHz CMC 0,82°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 1,0 300 kHz do 10 MHz CMC 1,4°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 1,0 10 MHz do 500 MHz CMC 1,5°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 1,0 500 MHz do 2 GHz CMC 1,2°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 1,5°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 50 Ω); S11 / S22 = 1,0 10 GHz do 18 GHz CMC 2,6°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 75 Ω); S11 / S22 = 0,0 9 kHz do 30 kHz CMC 0,0063\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 75 Ω); S11 / S22 = 0,0 30 kHz do 1,3 GHz CMC 0,0063\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 75 Ω); S11 / S22 = 0,0 1,3 GHz do 3 GHz CMC 0,011\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 75 Ω); S11 / S22 = 0,2 9 kHz do 30 kHz CMC 0,0079\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 75 Ω); S11 / S22 = 0,2 30 kHz do 1,3 GHz CMC 0,0078\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 75 Ω); S11 / S22 = 0,2 1,3 GHz do 3 GHz CMC 0,014\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 75 Ω); S11 / S22 = 0,6 9 kHz do 30 kHz CMC 0,013\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 75 Ω); S11 / S22 = 0,6 30 kHz do 1,3 GHz CMC 0,012\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 75 Ω); S11 / S22 = 0,6 1,3 GHz do 3 GHz CMC 0,025\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 75 Ω); S11 / S22 = 1,0 9 kHz do 30 kHz CMC 0,019\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 75 Ω); S11 / S22 = 1,0 30 kHz do 1,3 GHz CMC 0,018\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze N 75 Ω); S11 / S22 = 1,0 1,3 GHz do 3 GHz CMC 0,043\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 75 Ω); S11 / S22 = 0,0 9 kHz do 30 kHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 75 Ω); S11 / S22 = 0,0 30 kHz do 1,3 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 75 Ω); S11 / S22 = 0,0 1,3 GHz do 3 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 75 Ω); S11 / S22 = 0,2 9 kHz do 30 kHz CMC 2,3°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 75 Ω); S11 / S22 = 0,2 30 kHz do 1,3 GHz CMC 2,3°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 75 Ω); S11 / S22 = 0,2 1,3 GHz do 3 GHz CMC 3,9°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 75 Ω); S11 / S22 = 0,6 9 kHz do 30 kHz CMC 1,2°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 75 Ω); S11 / S22 = 0,6 30 kHz do 1,3 GHz CMC 1,2°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 75 Ω); S11 / S22 = 0,6 1,3 GHz do 3 GHz CMC 2,4°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 75 Ω); S11 / S22 = 1,0 9 kHz do 30 kHz CMC 1,1°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 75 Ω); S11 / S22 = 1,0 30 kHz do 1,3 GHz CMC 1,1°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze N 75 Ω); S11 / S22 = 1,0 1,3 GHz do 3 GHz CMC 2,5°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,0 9 kHz do 10 MHz CMC 0,012\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,0 10 MHz do 45 MHz CMC 0,0073\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,0 45 MHz do 500 MHz CMC 0,0073\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,0 500 MHz do 2 GHz CMC 0,0025\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 0,0033\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,0 10 GHz do 20 GHz CMC 0,0061\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,0 20 GHz do 26,5 GHz CMC 0,0096\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,2 9 kHz do 10 MHz CMC 0,014\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,2 10 MHz do 45 MHz CMC 0,011\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,2 45 MHz do 500 MHz CMC 0,0096\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,2 500 MHz do 2 GHz CMC 0,0037\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 0,0049\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,2 10 GHz do 20 GHz CMC 0,0081\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,2 20 GHz do 26,5 GHz CMC 0,013\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,6 9 kHz do 10 MHz CMC 0,022\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,6 10 MHz do 45 MHz CMC 0,022\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,6 45 MHz do 500 MHz CMC 0,017\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,6 500 MHz do 2 GHz CMC 0,0073\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 0,0099\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,6 10 GHz do 20 GHz CMC 0,014\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 0,6 20 GHz do 26,5 GHz CMC 0,021\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 1,0 9 kHz do 10 MHz CMC 0,036\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 1,0 10 MHz do 45 MHz CMC 0,036\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 1,0 45 MHz do 500 MHz CMC 0,028\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 1,0 500 MHz do 2 GHz CMC 0,013\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 0,017\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 1,0 10 GHz do 20 GHz CMC 0,023\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 3,5 mm); S11 / S22 = 1,0 20 GHz do 26,5 GHz CMC 0,033\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,0 9 kHz do 10 MHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,0 10 MHz do 45 MHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,0 45 MHz do 500 MHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,0 500 MHz do 2 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,0 10 GHz do 20 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,0 20 GHz do 26,5 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,2 9 kHz do 10 MHz CMC 4,0°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,2 10 MHz do 45 MHz CMC 3,1°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,2 45 MHz do 500 MHz CMC 2,8°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,2 500 MHz do 2 GHz CMC 1,1°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 1,5°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,2 10 GHz do 20 GHz CMC 2,3°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,2 20 GHz do 26,5 GHz CMC 3,5°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,6 9 kHz do 10 MHz CMC 2,1°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,6 10 MHz do 45 MHz CMC 2,1°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,6 45 MHz do 500 MHz CMC 1,6°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,6 500 MHz do 2 GHz CMC 0,70°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 0,95°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,6 10 GHz do 20 GHz CMC 1,4°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 0,6 20 GHz do 26,5 GHz CMC 2,0°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 1,0 9 kHz do 10 MHz CMC 2,1°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 1,0 10 MHz do 45 MHz CMC 2,1°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 1,0 45 MHz do 500 MHz CMC 1,6°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 1,0 500 MHz do 2 GHz CMC 0,73°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 0,98°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 1,0 10 GHz do 20 GHz CMC 1,3°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 3,5 mm); S11 / S22 = 1,0 20 GHz do 26,5 GHz CMC 1,9°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,0 9 kHz do 45 MHz CMC 0,015\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,0 45 MHz do 2 GHz CMC 0,0042\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 0,0055\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,0 10 GHz do 20 GHz CMC 0,0084\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,0 20 GHz do 40 GHz CMC 0,014\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,0 40 GHz do 50 GHz CMC 0,013\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,2 9 kHz do 45 MHz CMC 0,017\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,2 45 MHz do 2 GHz CMC 0,0058\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 0,0076\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,2 10 GHz do 20 GHz CMC 0,012\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,2 20 GHz do 40 GHz CMC 0,017\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,2 40 GHz do 50 GHz CMC 0,017\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,6 9 kHz do 45 MHz CMC 0,025\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,6 45 MHz do 2 GHz CMC 0,011\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 0,015\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,6 10 GHz do 20 GHz CMC 0,021\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,6 20 GHz do 40 GHz CMC 0,029\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 0,6 40 GHz do 50 GHz CMC 0,030\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 1,0 9 kHz do 45 MHz CMC 0,037\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 1,0 45 MHz do 2 GHz CMC 0,017\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 0,024\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 1,0 10 GHz do 20 GHz CMC 0,037\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 1,0 20 GHz do 40 GHz CMC 0,049\nMatryca CMC – wspolczynnik odbicia S11 / S22 – modul (zlacze 2,4 mm); S11 / S22 = 1,0 40 GHz do 50 GHz CMC 0,051\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,0 9 kHz do 45 MHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,0 45 MHz do 2 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,0 2 GHz do 10 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,0 10 GHz do 20 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,0 20 GHz do 40 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,0 40 GHz do 50 GHz CMC 180°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,2 9 kHz do 45 MHz CMC 4,8°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,2 45 MHz do 2 GHz CMC 1,7°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,2 2 GHz do 10 GHz CMC 2,2°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,2 10 GHz do 20 GHz CMC 3,2°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,2 20 GHz do 40 GHz CMC 4,8°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,2 40 GHz do 50 GHz CMC 8,0°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,6 9 kHz do 45 MHz CMC 2,4°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,6 45 MHz do 2 GHz CMC 0,97°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,6 2 GHz do 10 GHz CMC 1,4°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,6 10 GHz do 20 GHz CMC 2,1°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,6 20 GHz do 40 GHz CMC 2,8°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 0,6 40 GHz do 50 GHz CMC 4,3°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 1,0 9 kHz do 45 MHz CMC 2,1°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 1,0 45 MHz do 2 GHz CMC 0,96°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 1,0 2 GHz do 10 GHz CMC 1,4°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 1,0 10 GHz do 20 GHz CMC 2,2°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 1,0 20 GHz do 40 GHz CMC 2,9°\nMatryca CMC – wspolczynnik odbicia S11 / S22 – faza (zlacze 2,4 mm); S11 / S22 = 1,0 40 GHz do 50 GHz CMC 4,3°\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/34\nLMEEiO/48","search_en":"Frequency meters Power sensors Fixed loads (terminations, resistors) Fixed attenuators Variable attenuators Filters Directional couplers Switches Antenna and cable system analysers Measuring receivers Amplifiers - reflection coefficient S11 / S22 Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) 9 kHz to 50 GHz CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 50 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 50 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (N 75 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (N 75 Ω connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (3,5 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – magnitude (2,4 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,0 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,2 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 0,6 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0 CMC matrix – reflection coefficient S11 / S22 – phase (2,4 mm connector); S11 / S22 = 1,0 LMEEiO/34 LMEEiO/48","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":52,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"9 kHz bis 50 GHz","range":"0,0 to 1,0","cmc":"CMC-Matrix auf den folgenden Seiten"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,0","range":"9 kHz to 300 kHz","cmc":"0,0047"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,0","range":"300 kHz to 10 MHz","cmc":"0,0053"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,0","range":"10 MHz to 500 MHz","cmc":"0,0073"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"0,0058"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"0,0075"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,0","range":"10 GHz to 18 GHz","cmc":"0,012"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,2","range":"9 kHz to 300 kHz","cmc":"0,0062"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,2","range":"300 kHz to 10 MHz","cmc":"0,0072"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,2","range":"10 MHz to 500 MHz","cmc":"0,0089"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"0,0075"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"0,0094"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,2","range":"10 GHz to 18 GHz","cmc":"0,015"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,6","range":"9 kHz to 300 kHz","cmc":"0,0096"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,6","range":"300 kHz to 10 MHz","cmc":"0,014"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,6","range":"10 MHz to 500 MHz","cmc":"0,015"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"0,013"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,016"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,6","range":"10 GHz to 18 GHz","cmc":"0,026"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 1,0","range":"9 kHz to 300 kHz","cmc":"0,015"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 1,0","range":"300 kHz to 10 MHz","cmc":"0,024"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 1,0","range":"10 MHz to 500 MHz","cmc":"0,026"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"0,021"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,027"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 1,0","range":"10 GHz to 18 GHz","cmc":"0,045"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,0","range":"9 kHz to 300 kHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,0","range":"300 kHz to 10 MHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,0","range":"10 MHz to 500 MHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,0","range":"10 GHz to 18 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,2","range":"9 kHz to 300 kHz","cmc":"1,8°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,2","range":"300 kHz to 10 MHz","cmc":"2,1°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,2","range":"10 MHz to 500 MHz","cmc":"2,6°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"2,2°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"2,5°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,2","range":"10 GHz to 18 GHz","cmc":"4,2°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,6","range":"9 kHz to 300 kHz","cmc":"0,91°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,6","range":"300 kHz to 10 MHz","cmc":"1,3°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,6","range":"10 MHz to 500 MHz","cmc":"1,5°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"1,2°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"1,5°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,6","range":"10 GHz to 18 GHz","cmc":"2,4°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 1,0","range":"9 kHz to 300 kHz","cmc":"0,82°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 1,0","range":"300 kHz to 10 MHz","cmc":"1,4°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 1,0","range":"10 MHz to 500 MHz","cmc":"1,5°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"1,2°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"1,5°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 1,0","range":"10 GHz to 18 GHz","cmc":"2,6°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,0","range":"9 kHz to 30 kHz","cmc":"0,0063"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,0","range":"30 kHz to 1,3 GHz","cmc":"0,0063"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,0","range":"1,3 GHz to 3 GHz","cmc":"0,011"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,2","range":"9 kHz to 30 kHz","cmc":"0,0079"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,2","range":"30 kHz to 1,3 GHz","cmc":"0,0078"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,2","range":"1,3 GHz to 3 GHz","cmc":"0,014"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,6","range":"9 kHz to 30 kHz","cmc":"0,013"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,6","range":"30 kHz to 1,3 GHz","cmc":"0,012"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,6","range":"1,3 GHz to 3 GHz","cmc":"0,025"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 1,0","range":"9 kHz to 30 kHz","cmc":"0,019"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 1,0","range":"30 kHz to 1,3 GHz","cmc":"0,018"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 1,0","range":"1,3 GHz to 3 GHz","cmc":"0,043"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,0","range":"9 kHz to 30 kHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,0","range":"30 kHz to 1,3 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,0","range":"1,3 GHz to 3 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,2","range":"9 kHz to 30 kHz","cmc":"2,3°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,2","range":"30 kHz to 1,3 GHz","cmc":"2,3°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,2","range":"1,3 GHz to 3 GHz","cmc":"3,9°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,6","range":"9 kHz to 30 kHz","cmc":"1,2°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,6","range":"30 kHz to 1,3 GHz","cmc":"1,2°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,6","range":"1,3 GHz to 3 GHz","cmc":"2,4°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 1,0","range":"9 kHz to 30 kHz","cmc":"1,1°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 1,0","range":"30 kHz to 1,3 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 1,0","range":"1,3 GHz to 3 GHz","cmc":"2,5°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"9 kHz to 10 MHz","cmc":"0,012"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"10 MHz to 45 MHz","cmc":"0,0073"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"45 MHz to 500 MHz","cmc":"0,0073"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"0,0025"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"0,0033"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"10 GHz bis 20 GHz","cmc":"0,0061"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"20 GHz to 26,5 GHz","cmc":"0,0096"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"9 kHz to 10 MHz","cmc":"0,014"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"10 MHz to 45 MHz","cmc":"0,011"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"45 MHz to 500 MHz","cmc":"0,0096"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"0,0037"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"0,0049"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"10 GHz bis 20 GHz","cmc":"0,0081"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"20 GHz to 26,5 GHz","cmc":"0,013"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"9 kHz to 10 MHz","cmc":"0,022"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"10 MHz to 45 MHz","cmc":"0,022"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"45 MHz to 500 MHz","cmc":"0,017"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"0,0073"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,0099"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"10 GHz bis 20 GHz","cmc":"0,014"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"20 GHz to 26,5 GHz","cmc":"0,021"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"9 kHz to 10 MHz","cmc":"0,036"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"10 MHz to 45 MHz","cmc":"0,036"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"45 MHz to 500 MHz","cmc":"0,028"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"0,013"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,017"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"10 GHz bis 20 GHz","cmc":"0,023"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"20 GHz to 26,5 GHz","cmc":"0,033"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"9 kHz to 10 MHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"10 MHz to 45 MHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"45 MHz to 500 MHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"10 GHz bis 20 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0","range":"20 GHz to 26,5 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"9 kHz to 10 MHz","cmc":"4,0°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"10 MHz to 45 MHz","cmc":"3,1°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"45 MHz to 500 MHz","cmc":"2,8°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"1,5°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"10 GHz bis 20 GHz","cmc":"2,3°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2","range":"20 GHz to 26,5 GHz","cmc":"3,5°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"9 kHz to 10 MHz","cmc":"2,1°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"10 MHz to 45 MHz","cmc":"2,1°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"45 MHz to 500 MHz","cmc":"1,6°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"0,70°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,95°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"10 GHz bis 20 GHz","cmc":"1,4°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6","range":"20 GHz to 26,5 GHz","cmc":"2,0°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"9 kHz to 10 MHz","cmc":"2,1°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"10 MHz to 45 MHz","cmc":"2,1°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"45 MHz to 500 MHz","cmc":"1,6°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"0,73°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,98°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"10 GHz bis 20 GHz","cmc":"1,3°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0","range":"20 GHz to 26,5 GHz","cmc":"1,9°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,0","range":"9 kHz to 45 MHz","cmc":"0,015"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,0","range":"45 MHz to 2 GHz","cmc":"0,0042"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"0,0055"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,0","range":"10 GHz bis 20 GHz","cmc":"0,0084"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,0","range":"20 GHz to 40 GHz","cmc":"0,014"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,0","range":"40 GHz to 50 GHz","cmc":"0,013"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,2","range":"9 kHz to 45 MHz","cmc":"0,017"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,2","range":"45 MHz to 2 GHz","cmc":"0,0058"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"0,0076"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,2","range":"10 GHz bis 20 GHz","cmc":"0,012"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,2","range":"20 GHz to 40 GHz","cmc":"0,017"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,2","range":"40 GHz to 50 GHz","cmc":"0,017"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,6","range":"9 kHz to 45 MHz","cmc":"0,025"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,6","range":"45 MHz to 2 GHz","cmc":"0,011"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,015"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,6","range":"10 GHz bis 20 GHz","cmc":"0,021"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,6","range":"20 GHz to 40 GHz","cmc":"0,029"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,6","range":"40 GHz to 50 GHz","cmc":"0,030"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 1,0","range":"9 kHz to 45 MHz","cmc":"0,037"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 1,0","range":"45 MHz to 2 GHz","cmc":"0,017"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,024"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 1,0","range":"10 GHz bis 20 GHz","cmc":"0,037"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 1,0","range":"20 GHz to 40 GHz","cmc":"0,049"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 1,0","range":"40 GHz to 50 GHz","cmc":"0,051"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,0","range":"9 kHz to 45 MHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,0","range":"45 MHz to 2 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,0","range":"10 GHz bis 20 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,0","range":"20 GHz to 40 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,0","range":"40 GHz to 50 GHz","cmc":"180°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,2","range":"9 kHz to 45 MHz","cmc":"4,8°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,2","range":"45 MHz to 2 GHz","cmc":"1,7°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"2,2°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,2","range":"10 GHz bis 20 GHz","cmc":"3,2°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,2","range":"20 GHz to 40 GHz","cmc":"4,8°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,2","range":"40 GHz to 50 GHz","cmc":"8,0°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,6","range":"9 kHz to 45 MHz","cmc":"2,4°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,6","range":"45 MHz to 2 GHz","cmc":"0,97°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"1,4°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,6","range":"10 GHz bis 20 GHz","cmc":"2,1°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,6","range":"20 GHz to 40 GHz","cmc":"2,8°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,6","range":"40 GHz to 50 GHz","cmc":"4,3°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 1,0","range":"9 kHz to 45 MHz","cmc":"2,1°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 1,0","range":"45 MHz to 2 GHz","cmc":"0,96°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"1,4°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 1,0","range":"10 GHz bis 20 GHz","cmc":"2,2°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 1,0","range":"20 GHz to 40 GHz","cmc":"2,9°"},{"name":"CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 1,0","range":"40 GHz to 50 GHz","cmc":"4,3°"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Frequenzmesser Leistungssensoren Festlasten (Abschlüsse, Widerstände) Feste Dämpfungsglieder Einstellbare Dämpfungsglieder Filter Richtkoppler Schalter Analysatoren für Antennen- und Kabelsysteme Messempfänger Verstärker - Reflexionsfaktor S11 / S22 Kalibrierung — elektrische HF-Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 9 kHz bis 50 GHz CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 50 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 50 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder N 75 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder N 75 Ω); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 3,5 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Betrag (Steckverbinder 2,4 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,2 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 0,6 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 1,0 CMC-Matrix – Reflexionsfaktor S11 / S22 – Phase (Steckverbinder 2,4 mm); S11 / S22 = 1,0 LMEEiO/34 LMEEiO/48","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Frequenzmesser\nLeistungssensoren\nFestlasten (Abschlüsse, Widerstände)\nFeste Dämpfungsglieder\nEinstellbare Dämpfungsglieder\nFilter\nRichtkoppler\nSchalter\nAnalysatoren für Antennen- und Kabelsysteme\nMessempfänger\nVerstärker\n- Reflexionsfaktor S11 / S22","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"9 kHz 至 50 GHz","range":"0,0 to 1,0","cmc":"CMC 矩阵见后页"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,0","range":"9 kHz to 300 kHz","cmc":"0,0047"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,0","range":"300 kHz to 10 MHz","cmc":"0,0053"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,0","range":"10 MHz to 500 MHz","cmc":"0,0073"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"0,0058"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"0,0075"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,0","range":"10 GHz to 18 GHz","cmc":"0,012"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,2","range":"9 kHz to 300 kHz","cmc":"0,0062"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,2","range":"300 kHz to 10 MHz","cmc":"0,0072"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,2","range":"10 MHz to 500 MHz","cmc":"0,0089"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"0,0075"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"0,0094"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,2","range":"10 GHz to 18 GHz","cmc":"0,015"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,6","range":"9 kHz to 300 kHz","cmc":"0,0096"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,6","range":"300 kHz to 10 MHz","cmc":"0,014"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,6","range":"10 MHz to 500 MHz","cmc":"0,015"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"0,013"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,016"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,6","range":"10 GHz to 18 GHz","cmc":"0,026"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 1,0","range":"9 kHz to 300 kHz","cmc":"0,015"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 1,0","range":"300 kHz to 10 MHz","cmc":"0,024"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 1,0","range":"10 MHz to 500 MHz","cmc":"0,026"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"0,021"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,027"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 1,0","range":"10 GHz to 18 GHz","cmc":"0,045"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,0","range":"9 kHz to 300 kHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,0","range":"300 kHz to 10 MHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,0","range":"10 MHz to 500 MHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,0","range":"10 GHz to 18 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,2","range":"9 kHz to 300 kHz","cmc":"1,8°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,2","range":"300 kHz to 10 MHz","cmc":"2,1°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,2","range":"10 MHz to 500 MHz","cmc":"2,6°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"2,2°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"2,5°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,2","range":"10 GHz to 18 GHz","cmc":"4,2°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,6","range":"9 kHz to 300 kHz","cmc":"0,91°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,6","range":"300 kHz to 10 MHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,6","range":"10 MHz to 500 MHz","cmc":"1,5°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"1,2°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"1,5°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,6","range":"10 GHz to 18 GHz","cmc":"2,4°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 1,0","range":"9 kHz to 300 kHz","cmc":"0,82°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 1,0","range":"300 kHz to 10 MHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 1,0","range":"10 MHz to 500 MHz","cmc":"1,5°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"1,2°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"1,5°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 1,0","range":"10 GHz to 18 GHz","cmc":"2,6°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,0","range":"9 kHz to 30 kHz","cmc":"0,0063"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,0","range":"30 kHz to 1,3 GHz","cmc":"0,0063"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,0","range":"1,3 GHz to 3 GHz","cmc":"0,011"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,2","range":"9 kHz to 30 kHz","cmc":"0,0079"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,2","range":"30 kHz to 1,3 GHz","cmc":"0,0078"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,2","range":"1,3 GHz to 3 GHz","cmc":"0,014"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,6","range":"9 kHz to 30 kHz","cmc":"0,013"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,6","range":"30 kHz to 1,3 GHz","cmc":"0,012"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,6","range":"1,3 GHz to 3 GHz","cmc":"0,025"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 1,0","range":"9 kHz to 30 kHz","cmc":"0,019"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 1,0","range":"30 kHz to 1,3 GHz","cmc":"0,018"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 1,0","range":"1,3 GHz to 3 GHz","cmc":"0,043"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,0","range":"9 kHz to 30 kHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,0","range":"30 kHz to 1,3 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,0","range":"1,3 GHz to 3 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,2","range":"9 kHz to 30 kHz","cmc":"2,3°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,2","range":"30 kHz to 1,3 GHz","cmc":"2,3°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,2","range":"1,3 GHz to 3 GHz","cmc":"3,9°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,6","range":"9 kHz to 30 kHz","cmc":"1,2°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,6","range":"30 kHz to 1,3 GHz","cmc":"1,2°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,6","range":"1,3 GHz to 3 GHz","cmc":"2,4°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 1,0","range":"9 kHz to 30 kHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 1,0","range":"30 kHz to 1,3 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 1,0","range":"1,3 GHz to 3 GHz","cmc":"2,5°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0","range":"9 kHz to 10 MHz","cmc":"0,012"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0","range":"10 MHz to 45 MHz","cmc":"0,0073"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0","range":"45 MHz to 500 MHz","cmc":"0,0073"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"0,0025"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"0,0033"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0","range":"10 GHz 至 20 GHz","cmc":"0,0061"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0","range":"20 GHz to 26,5 GHz","cmc":"0,0096"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2","range":"9 kHz to 10 MHz","cmc":"0,014"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2","range":"10 MHz to 45 MHz","cmc":"0,011"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2","range":"45 MHz to 500 MHz","cmc":"0,0096"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"0,0037"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"0,0049"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2","range":"10 GHz 至 20 GHz","cmc":"0,0081"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2","range":"20 GHz to 26,5 GHz","cmc":"0,013"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6","range":"9 kHz to 10 MHz","cmc":"0,022"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6","range":"10 MHz to 45 MHz","cmc":"0,022"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6","range":"45 MHz to 500 MHz","cmc":"0,017"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"0,0073"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,0099"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6","range":"10 GHz 至 20 GHz","cmc":"0,014"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6","range":"20 GHz to 26,5 GHz","cmc":"0,021"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0","range":"9 kHz to 10 MHz","cmc":"0,036"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0","range":"10 MHz to 45 MHz","cmc":"0,036"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0","range":"45 MHz to 500 MHz","cmc":"0,028"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"0,013"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,017"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0","range":"10 GHz 至 20 GHz","cmc":"0,023"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0","range":"20 GHz to 26,5 GHz","cmc":"0,033"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0","range":"9 kHz to 10 MHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0","range":"10 MHz to 45 MHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0","range":"45 MHz to 500 MHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0","range":"10 GHz 至 20 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0","range":"20 GHz to 26,5 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2","range":"9 kHz to 10 MHz","cmc":"4,0°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2","range":"10 MHz to 45 MHz","cmc":"3,1°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2","range":"45 MHz to 500 MHz","cmc":"2,8°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"1,5°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2","range":"10 GHz 至 20 GHz","cmc":"2,3°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2","range":"20 GHz to 26,5 GHz","cmc":"3,5°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6","range":"9 kHz to 10 MHz","cmc":"2,1°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6","range":"10 MHz to 45 MHz","cmc":"2,1°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6","range":"45 MHz to 500 MHz","cmc":"1,6°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"0,70°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,95°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6","range":"10 GHz 至 20 GHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6","range":"20 GHz to 26,5 GHz","cmc":"2,0°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0","range":"9 kHz to 10 MHz","cmc":"2,1°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0","range":"10 MHz to 45 MHz","cmc":"2,1°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0","range":"45 MHz to 500 MHz","cmc":"1,6°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"0,73°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,98°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0","range":"10 GHz 至 20 GHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0","range":"20 GHz to 26,5 GHz","cmc":"1,9°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,0","range":"9 kHz to 45 MHz","cmc":"0,015"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,0","range":"45 MHz to 2 GHz","cmc":"0,0042"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"0,0055"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,0","range":"10 GHz 至 20 GHz","cmc":"0,0084"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,0","range":"20 GHz to 40 GHz","cmc":"0,014"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,0","range":"40 GHz to 50 GHz","cmc":"0,013"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,2","range":"9 kHz to 45 MHz","cmc":"0,017"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,2","range":"45 MHz to 2 GHz","cmc":"0,0058"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"0,0076"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,2","range":"10 GHz 至 20 GHz","cmc":"0,012"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,2","range":"20 GHz to 40 GHz","cmc":"0,017"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,2","range":"40 GHz to 50 GHz","cmc":"0,017"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,6","range":"9 kHz to 45 MHz","cmc":"0,025"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,6","range":"45 MHz to 2 GHz","cmc":"0,011"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,015"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,6","range":"10 GHz 至 20 GHz","cmc":"0,021"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,6","range":"20 GHz to 40 GHz","cmc":"0,029"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,6","range":"40 GHz to 50 GHz","cmc":"0,030"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 1,0","range":"9 kHz to 45 MHz","cmc":"0,037"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 1,0","range":"45 MHz to 2 GHz","cmc":"0,017"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,024"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 1,0","range":"10 GHz 至 20 GHz","cmc":"0,037"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 1,0","range":"20 GHz to 40 GHz","cmc":"0,049"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 1,0","range":"40 GHz to 50 GHz","cmc":"0,051"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,0","range":"9 kHz to 45 MHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,0","range":"45 MHz to 2 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,0","range":"10 GHz 至 20 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,0","range":"20 GHz to 40 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,0","range":"40 GHz to 50 GHz","cmc":"180°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,2","range":"9 kHz to 45 MHz","cmc":"4,8°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,2","range":"45 MHz to 2 GHz","cmc":"1,7°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"2,2°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,2","range":"10 GHz 至 20 GHz","cmc":"3,2°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,2","range":"20 GHz to 40 GHz","cmc":"4,8°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,2","range":"40 GHz to 50 GHz","cmc":"8,0°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,6","range":"9 kHz to 45 MHz","cmc":"2,4°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,6","range":"45 MHz to 2 GHz","cmc":"0,97°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,6","range":"10 GHz 至 20 GHz","cmc":"2,1°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,6","range":"20 GHz to 40 GHz","cmc":"2,8°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,6","range":"40 GHz to 50 GHz","cmc":"4,3°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 1,0","range":"9 kHz to 45 MHz","cmc":"2,1°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 1,0","range":"45 MHz to 2 GHz","cmc":"0,96°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 1,0","range":"10 GHz 至 20 GHz","cmc":"2,2°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 1,0","range":"20 GHz to 40 GHz","cmc":"2,9°"},{"name":"CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 1,0","range":"40 GHz to 50 GHz","cmc":"4,3°"}],"regulatory_area_zh":"射频电学量","search_zh":"频率计 功率传感器 固定负载（终端负载、电阻） 固定衰减器 可调衰减器 过滤器 定向耦合器 开关 天线与电缆系统分析仪 测量接收机 放大器 - 反射系数 S11 / S22 校准 — 射频电学量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 9 kHz 至 50 GHz CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 50 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 50 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (N 75 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (N 75 Ω 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (3,5 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 幅值 (2,4 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,2 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 0,6 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 1,0 CMC 矩阵 – 反射系数 S11 / S22 – 相位 (2,4 mm 连接器); S11 / S22 = 1,0 LMEEiO/34 LMEEiO/48","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"频率计\n功率传感器\n固定负载（终端负载、电阻）\n固定衰减器\n可调衰减器\n过滤器\n定向耦合器\n开关\n天线与电缆系统分析仪\n测量接收机\n放大器\n- 反射系数 S11 / S22","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"9 kHz až 50 GHz","range":"0,0 to 1,0","cmc":"Matice CMC na dalších stranách"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,0","range":"9 kHz to 300 kHz","cmc":"0,0047"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,0","range":"300 kHz to 10 MHz","cmc":"0,0053"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,0","range":"10 MHz to 500 MHz","cmc":"0,0073"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"0,0058"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"0,0075"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,0","range":"10 GHz to 18 GHz","cmc":"0,012"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,2","range":"9 kHz to 300 kHz","cmc":"0,0062"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,2","range":"300 kHz to 10 MHz","cmc":"0,0072"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,2","range":"10 MHz to 500 MHz","cmc":"0,0089"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"0,0075"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"0,0094"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,2","range":"10 GHz to 18 GHz","cmc":"0,015"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,6","range":"9 kHz to 300 kHz","cmc":"0,0096"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,6","range":"300 kHz to 10 MHz","cmc":"0,014"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,6","range":"10 MHz to 500 MHz","cmc":"0,015"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"0,013"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,016"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,6","range":"10 GHz to 18 GHz","cmc":"0,026"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 1,0","range":"9 kHz to 300 kHz","cmc":"0,015"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 1,0","range":"300 kHz to 10 MHz","cmc":"0,024"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 1,0","range":"10 MHz to 500 MHz","cmc":"0,026"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"0,021"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,027"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 1,0","range":"10 GHz to 18 GHz","cmc":"0,045"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,0","range":"9 kHz to 300 kHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,0","range":"300 kHz to 10 MHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,0","range":"10 MHz to 500 MHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,0","range":"10 GHz to 18 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,2","range":"9 kHz to 300 kHz","cmc":"1,8°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,2","range":"300 kHz to 10 MHz","cmc":"2,1°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,2","range":"10 MHz to 500 MHz","cmc":"2,6°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"2,2°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"2,5°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,2","range":"10 GHz to 18 GHz","cmc":"4,2°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,6","range":"9 kHz to 300 kHz","cmc":"0,91°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,6","range":"300 kHz to 10 MHz","cmc":"1,3°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,6","range":"10 MHz to 500 MHz","cmc":"1,5°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"1,2°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"1,5°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,6","range":"10 GHz to 18 GHz","cmc":"2,4°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 1,0","range":"9 kHz to 300 kHz","cmc":"0,82°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 1,0","range":"300 kHz to 10 MHz","cmc":"1,4°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 1,0","range":"10 MHz to 500 MHz","cmc":"1,5°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"1,2°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"1,5°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 1,0","range":"10 GHz to 18 GHz","cmc":"2,6°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,0","range":"9 kHz to 30 kHz","cmc":"0,0063"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,0","range":"30 kHz to 1,3 GHz","cmc":"0,0063"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,0","range":"1,3 GHz to 3 GHz","cmc":"0,011"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,2","range":"9 kHz to 30 kHz","cmc":"0,0079"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,2","range":"30 kHz to 1,3 GHz","cmc":"0,0078"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,2","range":"1,3 GHz to 3 GHz","cmc":"0,014"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,6","range":"9 kHz to 30 kHz","cmc":"0,013"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,6","range":"30 kHz to 1,3 GHz","cmc":"0,012"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,6","range":"1,3 GHz to 3 GHz","cmc":"0,025"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 1,0","range":"9 kHz to 30 kHz","cmc":"0,019"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 1,0","range":"30 kHz to 1,3 GHz","cmc":"0,018"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 1,0","range":"1,3 GHz to 3 GHz","cmc":"0,043"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,0","range":"9 kHz to 30 kHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,0","range":"30 kHz to 1,3 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,0","range":"1,3 GHz to 3 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,2","range":"9 kHz to 30 kHz","cmc":"2,3°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,2","range":"30 kHz to 1,3 GHz","cmc":"2,3°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,2","range":"1,3 GHz to 3 GHz","cmc":"3,9°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,6","range":"9 kHz to 30 kHz","cmc":"1,2°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,6","range":"30 kHz to 1,3 GHz","cmc":"1,2°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,6","range":"1,3 GHz to 3 GHz","cmc":"2,4°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 1,0","range":"9 kHz to 30 kHz","cmc":"1,1°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 1,0","range":"30 kHz to 1,3 GHz","cmc":"1,1°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 1,0","range":"1,3 GHz to 3 GHz","cmc":"2,5°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0","range":"9 kHz to 10 MHz","cmc":"0,012"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0","range":"10 MHz to 45 MHz","cmc":"0,0073"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0","range":"45 MHz to 500 MHz","cmc":"0,0073"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"0,0025"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"0,0033"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0","range":"10 GHz až 20 GHz","cmc":"0,0061"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0","range":"20 GHz to 26,5 GHz","cmc":"0,0096"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2","range":"9 kHz to 10 MHz","cmc":"0,014"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2","range":"10 MHz to 45 MHz","cmc":"0,011"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2","range":"45 MHz to 500 MHz","cmc":"0,0096"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"0,0037"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"0,0049"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2","range":"10 GHz až 20 GHz","cmc":"0,0081"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2","range":"20 GHz to 26,5 GHz","cmc":"0,013"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6","range":"9 kHz to 10 MHz","cmc":"0,022"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6","range":"10 MHz to 45 MHz","cmc":"0,022"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6","range":"45 MHz to 500 MHz","cmc":"0,017"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"0,0073"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,0099"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6","range":"10 GHz až 20 GHz","cmc":"0,014"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6","range":"20 GHz to 26,5 GHz","cmc":"0,021"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0","range":"9 kHz to 10 MHz","cmc":"0,036"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0","range":"10 MHz to 45 MHz","cmc":"0,036"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0","range":"45 MHz to 500 MHz","cmc":"0,028"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"0,013"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,017"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0","range":"10 GHz až 20 GHz","cmc":"0,023"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0","range":"20 GHz to 26,5 GHz","cmc":"0,033"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0","range":"9 kHz to 10 MHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0","range":"10 MHz to 45 MHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0","range":"45 MHz to 500 MHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0","range":"500 MHz to 2 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0","range":"10 GHz až 20 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0","range":"20 GHz to 26,5 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2","range":"9 kHz to 10 MHz","cmc":"4,0°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2","range":"10 MHz to 45 MHz","cmc":"3,1°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2","range":"45 MHz to 500 MHz","cmc":"2,8°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2","range":"500 MHz to 2 GHz","cmc":"1,1°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"1,5°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2","range":"10 GHz až 20 GHz","cmc":"2,3°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2","range":"20 GHz to 26,5 GHz","cmc":"3,5°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6","range":"9 kHz to 10 MHz","cmc":"2,1°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6","range":"10 MHz to 45 MHz","cmc":"2,1°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6","range":"45 MHz to 500 MHz","cmc":"1,6°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6","range":"500 MHz to 2 GHz","cmc":"0,70°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,95°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6","range":"10 GHz až 20 GHz","cmc":"1,4°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6","range":"20 GHz to 26,5 GHz","cmc":"2,0°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0","range":"9 kHz to 10 MHz","cmc":"2,1°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0","range":"10 MHz to 45 MHz","cmc":"2,1°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0","range":"45 MHz to 500 MHz","cmc":"1,6°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0","range":"500 MHz to 2 GHz","cmc":"0,73°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,98°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0","range":"10 GHz až 20 GHz","cmc":"1,3°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0","range":"20 GHz to 26,5 GHz","cmc":"1,9°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,0","range":"9 kHz to 45 MHz","cmc":"0,015"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,0","range":"45 MHz to 2 GHz","cmc":"0,0042"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"0,0055"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,0","range":"10 GHz až 20 GHz","cmc":"0,0084"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,0","range":"20 GHz to 40 GHz","cmc":"0,014"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,0","range":"40 GHz to 50 GHz","cmc":"0,013"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,2","range":"9 kHz to 45 MHz","cmc":"0,017"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,2","range":"45 MHz to 2 GHz","cmc":"0,0058"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"0,0076"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,2","range":"10 GHz až 20 GHz","cmc":"0,012"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,2","range":"20 GHz to 40 GHz","cmc":"0,017"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,2","range":"40 GHz to 50 GHz","cmc":"0,017"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,6","range":"9 kHz to 45 MHz","cmc":"0,025"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,6","range":"45 MHz to 2 GHz","cmc":"0,011"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"0,015"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,6","range":"10 GHz až 20 GHz","cmc":"0,021"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,6","range":"20 GHz to 40 GHz","cmc":"0,029"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,6","range":"40 GHz to 50 GHz","cmc":"0,030"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 1,0","range":"9 kHz to 45 MHz","cmc":"0,037"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 1,0","range":"45 MHz to 2 GHz","cmc":"0,017"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"0,024"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 1,0","range":"10 GHz až 20 GHz","cmc":"0,037"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 1,0","range":"20 GHz to 40 GHz","cmc":"0,049"},{"name":"Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 1,0","range":"40 GHz to 50 GHz","cmc":"0,051"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,0","range":"9 kHz to 45 MHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,0","range":"45 MHz to 2 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,0","range":"2 GHz to 10 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,0","range":"10 GHz až 20 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,0","range":"20 GHz to 40 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,0","range":"40 GHz to 50 GHz","cmc":"180°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,2","range":"9 kHz to 45 MHz","cmc":"4,8°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,2","range":"45 MHz to 2 GHz","cmc":"1,7°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,2","range":"2 GHz to 10 GHz","cmc":"2,2°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,2","range":"10 GHz až 20 GHz","cmc":"3,2°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,2","range":"20 GHz to 40 GHz","cmc":"4,8°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,2","range":"40 GHz to 50 GHz","cmc":"8,0°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,6","range":"9 kHz to 45 MHz","cmc":"2,4°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,6","range":"45 MHz to 2 GHz","cmc":"0,97°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,6","range":"2 GHz to 10 GHz","cmc":"1,4°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,6","range":"10 GHz až 20 GHz","cmc":"2,1°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,6","range":"20 GHz to 40 GHz","cmc":"2,8°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,6","range":"40 GHz to 50 GHz","cmc":"4,3°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 1,0","range":"9 kHz to 45 MHz","cmc":"2,1°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 1,0","range":"45 MHz to 2 GHz","cmc":"0,96°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 1,0","range":"2 GHz to 10 GHz","cmc":"1,4°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 1,0","range":"10 GHz až 20 GHz","cmc":"2,2°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 1,0","range":"20 GHz to 40 GHz","cmc":"2,9°"},{"name":"Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 1,0","range":"40 GHz to 50 GHz","cmc":"4,3°"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Měřiče kmitočtu Čidla výkonu Pevné zátěže (zakončení, rezistory) Pevné útlumové články Nastavitelné útlumové články Filtry Směrové vazební členy Spínače Analyzátory anténních a kabelových systémů Měřicí přijímače Zesilovače - činitel odrazu S11 / S22 Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 9 kHz až 50 GHz Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 50 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 50 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor N 75 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor N 75 Ω); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 3,5 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – modul (konektor 2,4 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,2 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 0,6 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 1,0 Matice CMC – činitel odrazu S11 / S22 – fáze (konektor 2,4 mm); S11 / S22 = 1,0 LMEEiO/34 LMEEiO/48","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče kmitočtu\nČidla výkonu\nPevné zátěže (zakončení, rezistory)\nPevné útlumové články\nNastavitelné útlumové články\nFiltry\nSměrové vazební členy\nSpínače\nAnalyzátory anténních a kabelových systémů\nMěřicí přijímače\nZesilovače\n- činitel odrazu S11 / S22"},{"_id":"bd802232276af404f3b9aecb","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Tłumiki stałe\nTłumiki regulowane\nFiltry\nSprzęgacze kierunkowe\nPrzełączniki\nAnalizatory systemów antenowych i kablowych\nWzmacniacze\n- transmisja S21 / S12","test_object_en":"Fixed attenuators\nVariable attenuators\nFilters\nDirectional couplers\nSwitches\nAntenna and cable system analysers\nAmplifiers\n- transmission S21 / S12","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — RF electrical quantities","parameters":[{"name":"9 kHz do 50 GHz","range":"-80 dB do 60 dB","cmc":"Matryca CMC na nast. str."},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB","range":"9 kHz do 300 kHz","cmc":"1,4"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB","range":"300 kHz do 10 MHz","cmc":"0,74"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB","range":"10 MHz do 500 MHz","cmc":"0,53"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB","range":"500 MHz do 2 GHz","cmc":"0,38"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB","range":"2 GHz do 10 GHz","cmc":"0,45"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB","range":"10 GHz do 18 GHz","cmc":"0,51"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB","range":"9 kHz do 300 kHz","cmc":"0,28"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB","range":"300 kHz do 10 MHz","cmc":"0,22"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB","range":"10 MHz do 500 MHz","cmc":"0,20"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB","range":"500 MHz do 2 GHz","cmc":"0,090"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB","range":"2 GHz do 10 GHz","cmc":"0,16"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB","range":"10 GHz do 18 GHz","cmc":"0,22"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB","range":"9 kHz do 300 kHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB","range":"300 kHz do 10 MHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB","range":"10 MHz do 500 MHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB","range":"500 MHz do 2 GHz","cmc":"0,050"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB","range":"2 GHz do 10 GHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB","range":"10 GHz do 18 GHz","cmc":"0,18"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB","range":"9 kHz do 300 kHz","cmc":"0,079"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB","range":"300 kHz do 10 MHz","cmc":"0,079"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB","range":"10 MHz do 500 MHz","cmc":"0,078"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB","range":"500 MHz do 2 GHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB","range":"2 GHz do 10 GHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB","range":"10 GHz do 18 GHz","cmc":"0,17"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB","range":"9 kHz do 300 kHz","cmc":"0,047"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB","range":"300 kHz do 10 MHz","cmc":"0,047"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB","range":"10 MHz do 500 MHz","cmc":"0,047"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB","range":"500 MHz do 2 GHz","cmc":"0,024"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB","range":"2 GHz do 10 GHz","cmc":"0,092"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB","range":"10 GHz do 18 GHz","cmc":"0,16"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB","range":"9 kHz do 300 kHz","cmc":"0,071"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB","range":"300 kHz do 10 MHz","cmc":"0,071"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB","range":"10 MHz do 500 MHz","cmc":"0,071"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB","range":"500 MHz do 2 GHz","cmc":"0,034"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB","range":"2 GHz do 10 GHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB","range":"10 GHz do 18 GHz","cmc":"0,16"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB","range":"9 kHz do 300 kHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB","range":"300 kHz do 10 MHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB","range":"10 MHz do 500 MHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB","range":"500 MHz do 2 GHz","cmc":"0,069"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB","range":"2 GHz do 10 GHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB","range":"10 GHz do 18 GHz","cmc":"0,20"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB","range":"9 kHz do 300 kHz","cmc":"0,20"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB","range":"300 kHz do 10 MHz","cmc":"0,20"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB","range":"10 MHz do 500 MHz","cmc":"0,20"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB","range":"500 MHz do 2 GHz","cmc":"0,079"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB","range":"2 GHz do 10 GHz","cmc":"0,15"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB","range":"10 GHz do 18 GHz","cmc":"0,21"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB","range":"9 kHz do 300 kHz","cmc":"9,6°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB","range":"300 kHz do 10 MHz","cmc":"5,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB","range":"10 MHz do 500 MHz","cmc":"3,7°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB","range":"500 MHz do 2 GHz","cmc":"2,6°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB","range":"2 GHz do 10 GHz","cmc":"3,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB","range":"10 GHz do 18 GHz","cmc":"3,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB","range":"9 kHz do 300 kHz","cmc":"1,9°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB","range":"300 kHz do 10 MHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB","range":"10 MHz do 500 MHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB","range":"500 MHz do 2 GHz","cmc":"0,60°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB","range":"2 GHz do 10 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB","range":"10 GHz do 18 GHz","cmc":"1,5°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB","range":"9 kHz do 300 kHz","cmc":"0,86°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB","range":"300 kHz do 10 MHz","cmc":"0,81°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB","range":"10 MHz do 500 MHz","cmc":"0,80°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB","range":"500 MHz do 2 GHz","cmc":"0,34°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB","range":"2 GHz do 10 GHz","cmc":"0,80°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB","range":"10 GHz do 18 GHz","cmc":"1,2°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB","range":"9 kHz do 300 kHz","cmc":"0,55°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB","range":"300 kHz do 10 MHz","cmc":"0,55°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB","range":"10 MHz do 500 MHz","cmc":"0,55°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB","range":"500 MHz do 2 GHz","cmc":"0,24°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB","range":"2 GHz do 10 GHz","cmc":"0,71°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB","range":"10 GHz do 18 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB","range":"9 kHz do 300 kHz","cmc":"0,31°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB","range":"300 kHz do 10 MHz","cmc":"0,31°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB","range":"10 MHz do 500 MHz","cmc":"0,31°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB","range":"500 MHz do 2 GHz","cmc":"0,16°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB","range":"2 GHz do 10 GHz","cmc":"0,59°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB","range":"10 GHz do 18 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB","range":"9 kHz do 300 kHz","cmc":"0,47°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB","range":"300 kHz do 10 MHz","cmc":"0,47°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB","range":"10 MHz do 500 MHz","cmc":"0,47°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB","range":"500 MHz do 2 GHz","cmc":"0,23°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB","range":"2 GHz do 10 GHz","cmc":"0,67°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB","range":"10 GHz do 18 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB","range":"9 kHz do 300 kHz","cmc":"0,75°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB","range":"300 kHz do 10 MHz","cmc":"0,75°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB","range":"10 MHz do 500 MHz","cmc":"0,75°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB","range":"500 MHz do 2 GHz","cmc":"0,49°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB","range":"2 GHz do 10 GHz","cmc":"0,95°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB","range":"10 GHz do 18 GHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB","range":"9 kHz do 300 kHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB","range":"300 kHz do 10 MHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB","range":"10 MHz do 500 MHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB","range":"500 MHz do 2 GHz","cmc":"0,57°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB","range":"2 GHz do 10 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB","range":"10 GHz do 18 GHz","cmc":"1,5°"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -80,0 dB","range":"9 kHz do 30 kHz","cmc":"0,54"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -80,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,37"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -80,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,40"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -60,0 dB","range":"9 kHz do 30 kHz","cmc":"0,20"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -60,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,15"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -60,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,17"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -40,0 dB","range":"9 kHz do 30 kHz","cmc":"0,13"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -40,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,10"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -40,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -20,0 dB","range":"9 kHz do 30 kHz","cmc":"0,081"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -20,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,073"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -20,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,093"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 0,0 dB","range":"9 kHz do 30 kHz","cmc":"0,057"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 0,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,050"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 0,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,070"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 20,0 dB","range":"9 kHz do 30 kHz","cmc":"0,081"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 20,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,074"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 20,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,093"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 40,0 dB","range":"9 kHz do 30 kHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 40,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 40,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,13"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 60,0 dB","range":"9 kHz do 30 kHz","cmc":"0,21"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 60,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,15"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 60,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,18"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -80,0 dB","range":"9 kHz do 30 kHz","cmc":"3,7°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -80,0 dB","range":"30 kHz do 1,3 GHz","cmc":"2,7°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -80,0 dB","range":"1,3 GHz do 3 GHz","cmc":"2,9°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -60,0 dB","range":"9 kHz do 30 kHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -60,0 dB","range":"30 kHz do 1,3 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -60,0 dB","range":"1,3 GHz do 3 GHz","cmc":"1,2°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -40,0 dB","range":"9 kHz do 30 kHz","cmc":"0,83°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -40,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,68°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -40,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,81°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -20,0 dB","range":"9 kHz do 30 kHz","cmc":"0,54°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -20,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,49°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -20,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,62°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 0,0 dB","range":"9 kHz do 30 kHz","cmc":"0,38°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 0,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,33°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 0,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,47°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 20,0 dB","range":"9 kHz do 30 kHz","cmc":"0,54°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 20,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,50°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 20,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,63°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 40,0 dB","range":"9 kHz do 30 kHz","cmc":"0,80°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 40,0 dB","range":"30 kHz do 1,3 GHz","cmc":"0,69°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 40,0 dB","range":"1,3 GHz do 3 GHz","cmc":"0,84°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 60,0 dB","range":"9 kHz do 30 kHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 60,0 dB","range":"30 kHz do 1,3 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 60,0 dB","range":"1,3 GHz do 3 GHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"9 kHz do 10 MHz","cmc":"0,75"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"10 MHz do 45 MHz","cmc":"0,55"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"45 MHz do 500 MHz","cmc":"0,55"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"500 MHz do 2 GHz","cmc":"0,43"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"2 GHz do 10 GHz","cmc":"0,46"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"10 GHz do 20 GHz","cmc":"0,49"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"20 GHz do 26,5 GHz","cmc":"0,52"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"9 kHz do 10 MHz","cmc":"0,24"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"10 MHz do 45 MHz","cmc":"0,22"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"45 MHz do 500 MHz","cmc":"0,22"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"500 MHz do 2 GHz","cmc":"0,15"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"2 GHz do 10 GHz","cmc":"0,17"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"10 GHz do 20 GHz","cmc":"0,20"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"20 GHz do 26,5 GHz","cmc":"0,23"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"9 kHz do 10 MHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"10 MHz do 45 MHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"45 MHz do 500 MHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"500 MHz do 2 GHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"2 GHz do 10 GHz","cmc":"0,13"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"10 GHz do 20 GHz","cmc":"0,17"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"20 GHz do 26,5 GHz","cmc":"0,20"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"9 kHz do 10 MHz","cmc":"0,098"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"10 MHz do 45 MHz","cmc":"0,098"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"45 MHz do 500 MHz","cmc":"0,098"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"500 MHz do 2 GHz","cmc":"0,079"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"2 GHz do 10 GHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"10 GHz do 20 GHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"20 GHz do 26,5 GHz","cmc":"0,17"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"9 kHz do 10 MHz","cmc":"0,066"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"10 MHz do 45 MHz","cmc":"0,066"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"45 MHz do 500 MHz","cmc":"0,066"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"500 MHz do 2 GHz","cmc":"0,066"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"2 GHz do 10 GHz","cmc":"0,092"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"10 GHz do 20 GHz","cmc":"0,13"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"20 GHz do 26,5 GHz","cmc":"0,16"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"9 kHz do 10 MHz","cmc":"0,099"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"10 MHz do 45 MHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"45 MHz do 500 MHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"500 MHz do 2 GHz","cmc":"0,097"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"2 GHz do 10 GHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"10 GHz do 20 GHz","cmc":"0,15"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"20 GHz do 26,5 GHz","cmc":"0,19"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"9 kHz do 10 MHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"10 MHz do 45 MHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"45 MHz do 500 MHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"500 MHz do 2 GHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"2 GHz do 10 GHz","cmc":"0,13"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"10 GHz do 20 GHz","cmc":"0,17"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"20 GHz do 26,5 GHz","cmc":"0,20"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"9 kHz do 10 MHz","cmc":"0,19"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"10 MHz do 45 MHz","cmc":"0,13"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"45 MHz do 500 MHz","cmc":"0,13"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"500 MHz do 2 GHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"2 GHz do 10 GHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"10 GHz do 20 GHz","cmc":"0,18"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"20 GHz do 26,5 GHz","cmc":"0,21"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"9 kHz do 10 MHz","cmc":"5,2°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"10 MHz do 45 MHz","cmc":"3,8°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"45 MHz do 500 MHz","cmc":"3,8°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"500 MHz do 2 GHz","cmc":"3,0°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"2 GHz do 10 GHz","cmc":"3,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"10 GHz do 20 GHz","cmc":"3,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB","range":"20 GHz do 26,5 GHz","cmc":"3,5°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"9 kHz do 10 MHz","cmc":"1,6°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"10 MHz do 45 MHz","cmc":"11,5°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"45 MHz do 500 MHz","cmc":"1,5°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"500 MHz do 2 GHz","cmc":"0,96°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"2 GHz do 10 GHz","cmc":"1,2°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"10 GHz do 20 GHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB","range":"20 GHz do 26,5 GHz","cmc":"1,6°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"9 kHz do 10 MHz","cmc":"0,94°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"10 MHz do 45 MHz","cmc":"0,93°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"45 MHz do 500 MHz","cmc":"0,93°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"500 MHz do 2 GHz","cmc":"0,71°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"2 GHz do 10 GHz","cmc":"0,86°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"10 GHz do 20 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB","range":"20 GHz do 26,5 GHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"9 kHz do 10 MHz","cmc":"0,68°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"10 MHz do 45 MHz","cmc":"0,68°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"45 MHz do 500 MHz","cmc":"0,68°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"500 MHz do 2 GHz","cmc":"0,53°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"2 GHz do 10 GHz","cmc":"0,71°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"10 GHz do 20 GHz","cmc":"0,94°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB","range":"20 GHz do 26,5 GHz","cmc":"1,2°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"9 kHz do 10 MHz","cmc":"0,44°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"10 MHz do 45 MHz","cmc":"0,44°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"45 MHz do 500 MHz","cmc":"0,44°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"500 MHz do 2 GHz","cmc":"0,44°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"2 GHz do 10 GHz","cmc":"0,61°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"10 GHz do 20 GHz","cmc":"0,84°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB","range":"20 GHz do 26,5 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"9 kHz do 10 MHz","cmc":"0,68°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"10 MHz do 45 MHz","cmc":"0,67°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"45 MHz do 500 MHz","cmc":"0,69°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"500 MHz do 2 GHz","cmc":"0,69°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"2 GHz do 10 GHz","cmc":"0,80°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"10 GHz do 20 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB","range":"20 GHz do 26,5 GHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"9 kHz do 10 MHz","cmc":"0,93°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"10 MHz do 45 MHz","cmc":"0,74°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"45 MHz do 500 MHz","cmc":"0,76°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"500 MHz do 2 GHz","cmc":"0,76°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"2 GHz do 10 GHz","cmc":"0,87°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"10 GHz do 20 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB","range":"20 GHz do 26,5 GHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"9 kHz do 10 MHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"10 MHz do 45 MHz","cmc":"0,82°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"45 MHz do 500 MHz","cmc":"0,83°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"500 MHz do 2 GHz","cmc":"0,83°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"2 GHz do 10 GHz","cmc":"0,95°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"10 GHz do 20 GHz","cmc":"1,2°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB","range":"20 GHz do 26,5 GHz","cmc":"1,5°"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"9 kHz do 10 MHz","cmc":"0,75"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"10 MHz do 45 MHz","cmc":"0,55"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"45 MHz do 500 MHz","cmc":"0,55"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"500 MHz do 2 GHz","cmc":"0,41"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"2 GHz do 10 GHz","cmc":"0,42"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"10 GHz do 20 GHz","cmc":"0,45"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"20 GHz do 35 GHz","cmc":"0,48"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"35 GHz do 44 GHz","cmc":"0,71"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"44 GHz do 50 GHz","cmc":"1,9"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"9 kHz do 10 MHz","cmc":"0,24"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"10 MHz do 45 MHz","cmc":"0,22"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"45 MHz do 500 MHz","cmc":"0,19"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"500 MHz do 2 GHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"2 GHz do 10 GHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"10 GHz do 20 GHz","cmc":"0,16"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"20 GHz do 35 GHz","cmc":"0,19"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"35 GHz do 44 GHz","cmc":"0,22"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"44 GHz do 50 GHz","cmc":"0,39"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"9 kHz do 10 MHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"10 MHz do 45 MHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"45 MHz do 500 MHz","cmc":"0,086"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"500 MHz do 2 GHz","cmc":"0,079"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"2 GHz do 10 GHz","cmc":"0,093"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"10 GHz do 20 GHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"20 GHz do 35 GHz","cmc":"0,15"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"35 GHz do 44 GHz","cmc":"0,16"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"44 GHz do 50 GHz","cmc":"0,23"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"9 kHz do 10 MHz","cmc":"0,098"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"10 MHz do 45 MHz","cmc":"0,098"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"45 MHz do 500 MHz","cmc":"0,065"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"500 MHz do 2 GHz","cmc":"0,066"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"2 GHz do 10 GHz","cmc":"0,080"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"10 GHz do 20 GHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"20 GHz do 35 GHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"35 GHz do 44 GHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"44 GHz do 50 GHz","cmc":"0,20"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"9 kHz do 10 MHz","cmc":"0,066"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"10 MHz do 45 MHz","cmc":"0,066"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"45 MHz do 500 MHz","cmc":"0,056"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"500 MHz do 2 GHz","cmc":"0,052"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"2 GHz do 10 GHz","cmc":"0,066"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"10 GHz do 20 GHz","cmc":"0,089"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"20 GHz do 35 GHz","cmc":"0,13"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"35 GHz do 44 GHz","cmc":"0,13"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"44 GHz do 50 GHz","cmc":"0,19"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"9 kHz do 10 MHz","cmc":"0,17"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"10 MHz do 45 MHz","cmc":"0,17"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"45 MHz do 500 MHz","cmc":"0,064"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"500 MHz do 2 GHz","cmc":"0,083"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"2 GHz do 10 GHz","cmc":"0,92"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"10 GHz do 20 GHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"20 GHz do 35 GHz","cmc":"0,16"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"35 GHz do 44 GHz","cmc":"0,17"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"44 GHz do 50 GHz","cmc":"0,23"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"9 kHz do 10 MHz","cmc":"0,20"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"10 MHz do 45 MHz","cmc":"0,20"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"45 MHz do 500 MHz","cmc":"0,075"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"500 MHz do 2 GHz","cmc":"0,095"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"2 GHz do 10 GHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"10 GHz do 20 GHz","cmc":"0,13"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"20 GHz do 35 GHz","cmc":"0,17"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"35 GHz do 44 GHz","cmc":"0,18"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"44 GHz do 50 GHz","cmc":"0,24"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"9 kHz do 10 MHz","cmc":"0,21"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"10 MHz do 45 MHz","cmc":"0,21"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"45 MHz do 500 MHz","cmc":"0,086"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"500 MHz do 2 GHz","cmc":"0,11"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"2 GHz do 10 GHz","cmc":"0,12"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"10 GHz do 20 GHz","cmc":"0,14"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"20 GHz do 35 GHz","cmc":"0,18"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"35 GHz do 44 GHz","cmc":"0,19"},{"name":"Matryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"44 GHz do 50 GHz","cmc":"0,25"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"9 kHz do 10 MHz","cmc":"5,2°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"10 MHz do 45 MHz","cmc":"3,8°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"45 MHz do 500 MHz","cmc":"3,8°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"500 MHz do 2 GHz","cmc":"2,8°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"2 GHz do 10 GHz","cmc":"2,9°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"10 GHz do 20 GHz","cmc":"3,0°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"20 GHz do 35 GHz","cmc":"3,2°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"35 GHz do 44 GHz","cmc":"4,9°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB","range":"44 GHz do 50 GHz","cmc":"14°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"9 kHz do 10 MHz","cmc":"1,6°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"10 MHz do 45 MHz","cmc":"1,5°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"45 MHz do 500 MHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"500 MHz do 2 GHz","cmc":"0,79°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"2 GHz do 10 GHz","cmc":"0,88°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"10 GHz do 20 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"20 GHz do 35 GHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"35 GHz do 44 GHz","cmc":"1,5°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB","range":"44 GHz do 50 GHz","cmc":"2,7°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"9 kHz do 10 MHz","cmc":"0,94°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"10 MHz do 45 MHz","cmc":"0,93°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"45 MHz do 500 MHz","cmc":"0,57°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"500 MHz do 2 GHz","cmc":"0,53°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"2 GHz do 10 GHz","cmc":"0,62°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"10 GHz do 20 GHz","cmc":"0,77°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"20 GHz do 35 GHz","cmc":"0,97°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"35 GHz do 44 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB","range":"44 GHz do 50 GHz","cmc":"1,5°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"9 kHz do 10 MHz","cmc":"0,68°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"10 MHz do 45 MHz","cmc":"0,68°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"45 MHz do 500 MHz","cmc":"0,43°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"500 MHz do 2 GHz","cmc":"0,44°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"2 GHz do 10 GHz","cmc":"0,53°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"10 GHz do 20 GHz","cmc":"0,68°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"20 GHz do 35 GHz","cmc":"0,88°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"35 GHz do 44 GHz","cmc":"0,90°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB","range":"44 GHz do 50 GHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"9 kHz do 10 MHz","cmc":"0,44°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"10 MHz do 45 MHz","cmc":"0,44°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"45 MHz do 500 MHz","cmc":"0,37°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"500 MHz do 2 GHz","cmc":"0,35°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"2 GHz do 10 GHz","cmc":"0,44°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"10 GHz do 20 GHz","cmc":"0,59°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"20 GHz do 35 GHz","cmc":"0,81°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"35 GHz do 44 GHz","cmc":"0,82°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB","range":"44 GHz do 50 GHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"9 kHz do 10 MHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"10 MHz do 45 MHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"45 MHz do 500 MHz","cmc":"0,42°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"500 MHz do 2 GHz","cmc":"0,59°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"2 GHz do 10 GHz","cmc":"0,63°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"10 GHz do 20 GHz","cmc":"0,77°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"20 GHz do 35 GHz","cmc":"1,1°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"35 GHz do 44 GHz","cmc":"1,2°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB","range":"44 GHz do 50 GHz","cmc":"1,6°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"9 kHz do 10 MHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"10 MHz do 45 MHz","cmc":"1,4°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"45 MHz do 500 MHz","cmc":"0,50°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"500 MHz do 2 GHz","cmc":"0,67°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"2 GHz do 10 GHz","cmc":"0,70°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"10 GHz do 20 GHz","cmc":"0,84°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"20 GHz do 35 GHz","cmc":"1,2°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"35 GHz do 44 GHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB","range":"44 GHz do 50 GHz","cmc":"1,7°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"9 kHz do 10 MHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"10 MHz do 45 MHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"45 MHz do 500 MHz","cmc":"0,57°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"500 MHz do 2 GHz","cmc":"0,74°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"2 GHz do 10 GHz","cmc":"0.77°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"10 GHz do 20 GHz","cmc":"0,92°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"20 GHz do 35 GHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"35 GHz do 44 GHz","cmc":"1,3°"},{"name":"Matryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB","range":"44 GHz do 50 GHz","cmc":"1,7°"}],"parameters_en":[{"name":"9 kHz to 50 GHz","range":"-80 dB to 60 dB","cmc":"CMC matrix on the following pages"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB","range":"9 kHz to 300 kHz","cmc":"1,4"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB","range":"300 kHz to 10 MHz","cmc":"0,74"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB","range":"10 MHz to 500 MHz","cmc":"0,53"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"0,38"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"0,45"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB","range":"10 GHz to 18 GHz","cmc":"0,51"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB","range":"9 kHz to 300 kHz","cmc":"0,28"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB","range":"300 kHz to 10 MHz","cmc":"0,22"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB","range":"10 MHz to 500 MHz","cmc":"0,20"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,090"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,16"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB","range":"10 GHz to 18 GHz","cmc":"0,22"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,050"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB","range":"10 GHz to 18 GHz","cmc":"0,18"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,079"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,079"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,078"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB","range":"10 GHz to 18 GHz","cmc":"0,17"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB","range":"9 kHz to 300 kHz","cmc":"0,047"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB","range":"300 kHz to 10 MHz","cmc":"0,047"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB","range":"10 MHz to 500 MHz","cmc":"0,047"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,024"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,092"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB","range":"10 GHz to 18 GHz","cmc":"0,16"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,071"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,071"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,071"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,034"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB","range":"10 GHz to 18 GHz","cmc":"0,16"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,069"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB","range":"10 GHz to 18 GHz","cmc":"0,20"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB","range":"9 kHz to 300 kHz","cmc":"0,20"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB","range":"300 kHz to 10 MHz","cmc":"0,20"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB","range":"10 MHz to 500 MHz","cmc":"0,20"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,079"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,15"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB","range":"10 GHz to 18 GHz","cmc":"0,21"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB","range":"9 kHz to 300 kHz","cmc":"9,6°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB","range":"300 kHz to 10 MHz","cmc":"5,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB","range":"10 MHz to 500 MHz","cmc":"3,7°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"2,6°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"3,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB","range":"10 GHz to 18 GHz","cmc":"3,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB","range":"9 kHz to 300 kHz","cmc":"1,9°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB","range":"300 kHz to 10 MHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB","range":"10 MHz to 500 MHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,60°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB","range":"10 GHz to 18 GHz","cmc":"1,5°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,86°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,81°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,80°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,34°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,80°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB","range":"10 GHz to 18 GHz","cmc":"1,2°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,55°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,55°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,55°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,24°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,71°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB","range":"10 GHz to 18 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB","range":"9 kHz to 300 kHz","cmc":"0,31°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB","range":"300 kHz to 10 MHz","cmc":"0,31°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB","range":"10 MHz to 500 MHz","cmc":"0,31°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,16°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,59°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB","range":"10 GHz to 18 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,47°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,47°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,47°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,23°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,67°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB","range":"10 GHz to 18 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,75°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,75°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,75°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,49°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,95°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB","range":"10 GHz to 18 GHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB","range":"9 kHz to 300 kHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB","range":"300 kHz to 10 MHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB","range":"10 MHz to 500 MHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,57°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB","range":"10 GHz to 18 GHz","cmc":"1,5°"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -80,0 dB","range":"9 kHz to 30 kHz","cmc":"0,54"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -80,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,37"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -80,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,40"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -60,0 dB","range":"9 kHz to 30 kHz","cmc":"0,20"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,15"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,17"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,13"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,10"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,081"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,073"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,093"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 0,0 dB","range":"9 kHz to 30 kHz","cmc":"0,057"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 0,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,050"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 0,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,070"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,081"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,074"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,093"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,13"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 60,0 dB","range":"9 kHz to 30 kHz","cmc":"0,21"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,15"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,18"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -80,0 dB","range":"9 kHz to 30 kHz","cmc":"3,7°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -80,0 dB","range":"30 kHz to 1,3 GHz","cmc":"2,7°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -80,0 dB","range":"1,3 GHz to 3 GHz","cmc":"2,9°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -60,0 dB","range":"9 kHz to 30 kHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"1,2°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,83°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,68°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,81°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,54°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,49°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,62°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 0,0 dB","range":"9 kHz to 30 kHz","cmc":"0,38°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 0,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,33°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 0,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,47°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,54°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,50°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,63°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,80°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,69°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,84°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 60,0 dB","range":"9 kHz to 30 kHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"0,75"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"0,55"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"0,55"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"0,43"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"0,46"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB","range":"10 GHz to 20 GHz","cmc":"0,49"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,52"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,24"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,22"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,22"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,15"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,17"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB","range":"10 GHz to 20 GHz","cmc":"0,20"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,23"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,13"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB","range":"10 GHz to 20 GHz","cmc":"0,17"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,20"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,098"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,098"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,098"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,079"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB","range":"10 GHz to 20 GHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,17"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,066"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,066"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,066"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,066"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,092"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB","range":"10 GHz to 20 GHz","cmc":"0,13"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,16"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,099"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,097"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB","range":"10 GHz to 20 GHz","cmc":"0,15"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,19"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,13"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB","range":"10 GHz to 20 GHz","cmc":"0,17"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,20"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,19"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,13"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,13"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB","range":"10 GHz to 20 GHz","cmc":"0,18"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,21"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"5,2°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"3,8°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"3,8°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"3,0°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"3,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB","range":"10 GHz to 20 GHz","cmc":"3,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB","range":"20 GHz to 26,5 GHz","cmc":"3,5°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,6°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"11,5°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"1,5°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,96°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"1,2°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB","range":"10 GHz to 20 GHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,6°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,94°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,93°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,93°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,71°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,86°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB","range":"10 GHz to 20 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,68°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,68°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,68°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,53°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,71°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB","range":"10 GHz to 20 GHz","cmc":"0,94°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,2°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,44°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,44°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,44°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,44°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,61°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB","range":"10 GHz to 20 GHz","cmc":"0,84°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,68°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,67°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,69°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,69°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,80°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB","range":"10 GHz to 20 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,93°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,74°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,76°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,76°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,87°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB","range":"10 GHz to 20 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,82°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,83°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,83°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,95°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB","range":"10 GHz to 20 GHz","cmc":"1,2°"},{"name":"CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,5°"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"0,75"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"0,55"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"0,55"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"0,41"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"0,42"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB","range":"10 GHz to 20 GHz","cmc":"0,45"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB","range":"20 GHz to 35 GHz","cmc":"0,48"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB","range":"35 GHz to 44 GHz","cmc":"0,71"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB","range":"44 GHz to 50 GHz","cmc":"1,9"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,24"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,22"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,19"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB","range":"10 GHz to 20 GHz","cmc":"0,16"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB","range":"20 GHz to 35 GHz","cmc":"0,19"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB","range":"35 GHz to 44 GHz","cmc":"0,22"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB","range":"44 GHz to 50 GHz","cmc":"0,39"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,086"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,079"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,093"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB","range":"10 GHz to 20 GHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB","range":"20 GHz to 35 GHz","cmc":"0,15"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB","range":"35 GHz to 44 GHz","cmc":"0,16"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB","range":"44 GHz to 50 GHz","cmc":"0,23"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,098"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,098"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,065"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,066"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,080"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB","range":"10 GHz to 20 GHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB","range":"20 GHz to 35 GHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB","range":"35 GHz to 44 GHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB","range":"44 GHz to 50 GHz","cmc":"0,20"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,066"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,066"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,056"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,052"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,066"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB","range":"10 GHz to 20 GHz","cmc":"0,089"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB","range":"20 GHz to 35 GHz","cmc":"0,13"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB","range":"35 GHz to 44 GHz","cmc":"0,13"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB","range":"44 GHz to 50 GHz","cmc":"0,19"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,17"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,17"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,064"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,083"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,92"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB","range":"10 GHz to 20 GHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB","range":"20 GHz to 35 GHz","cmc":"0,16"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB","range":"35 GHz to 44 GHz","cmc":"0,17"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB","range":"44 GHz to 50 GHz","cmc":"0,23"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,20"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,20"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,075"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,095"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB","range":"10 GHz to 20 GHz","cmc":"0,13"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB","range":"20 GHz to 35 GHz","cmc":"0,17"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB","range":"35 GHz to 44 GHz","cmc":"0,18"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB","range":"44 GHz to 50 GHz","cmc":"0,24"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,21"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,21"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,086"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,12"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB","range":"10 GHz to 20 GHz","cmc":"0,14"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB","range":"20 GHz to 35 GHz","cmc":"0,18"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB","range":"35 GHz to 44 GHz","cmc":"0,19"},{"name":"CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB","range":"44 GHz to 50 GHz","cmc":"0,25"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"5,2°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"3,8°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"3,8°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"2,8°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"2,9°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB","range":"10 GHz to 20 GHz","cmc":"3,0°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB","range":"20 GHz to 35 GHz","cmc":"3,2°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB","range":"35 GHz to 44 GHz","cmc":"4,9°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB","range":"44 GHz to 50 GHz","cmc":"14°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,6°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"1,5°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,79°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,88°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB","range":"10 GHz to 20 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB","range":"20 GHz to 35 GHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB","range":"35 GHz to 44 GHz","cmc":"1,5°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB","range":"44 GHz to 50 GHz","cmc":"2,7°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,94°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,93°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,57°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,53°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,62°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB","range":"10 GHz to 20 GHz","cmc":"0,77°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB","range":"20 GHz to 35 GHz","cmc":"0,97°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB","range":"35 GHz to 44 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB","range":"44 GHz to 50 GHz","cmc":"1,5°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,68°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,68°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,43°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,44°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,53°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB","range":"10 GHz to 20 GHz","cmc":"0,68°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB","range":"20 GHz to 35 GHz","cmc":"0,88°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB","range":"35 GHz to 44 GHz","cmc":"0,90°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB","range":"44 GHz to 50 GHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,44°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,44°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,37°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,35°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,44°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB","range":"10 GHz to 20 GHz","cmc":"0,59°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB","range":"20 GHz to 35 GHz","cmc":"0,81°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB","range":"35 GHz to 44 GHz","cmc":"0,82°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB","range":"44 GHz to 50 GHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,42°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,59°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,63°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB","range":"10 GHz to 20 GHz","cmc":"0,77°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB","range":"20 GHz to 35 GHz","cmc":"1,1°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB","range":"35 GHz to 44 GHz","cmc":"1,2°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB","range":"44 GHz to 50 GHz","cmc":"1,6°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"1,4°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,50°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,67°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,70°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB","range":"10 GHz to 20 GHz","cmc":"0,84°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB","range":"20 GHz to 35 GHz","cmc":"1,2°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB","range":"35 GHz to 44 GHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB","range":"44 GHz to 50 GHz","cmc":"1,7°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,57°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,74°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0.77°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB","range":"10 GHz to 20 GHz","cmc":"0,92°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB","range":"20 GHz to 35 GHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB","range":"35 GHz to 44 GHz","cmc":"1,3°"},{"name":"CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB","range":"44 GHz to 50 GHz","cmc":"1,7°"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\n9 kHz do 50 GHz -80 dB do 60 dB CMC Matryca CMC na nast. str.\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB 9 kHz do 300 kHz CMC 1,4\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB 300 kHz do 10 MHz CMC 0,74\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB 10 MHz do 500 MHz CMC 0,53\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 0,38\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 0,45\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB 10 GHz do 18 GHz CMC 0,51\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB 9 kHz do 300 kHz CMC 0,28\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB 300 kHz do 10 MHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB 10 MHz do 500 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,090\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB 10 GHz do 18 GHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB 9 kHz do 300 kHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB 300 kHz do 10 MHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB 10 MHz do 500 MHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,050\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB 10 GHz do 18 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB 9 kHz do 300 kHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB 300 kHz do 10 MHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB 10 MHz do 500 MHz CMC 0,078\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB 10 GHz do 18 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB 9 kHz do 300 kHz CMC 0,047\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB 300 kHz do 10 MHz CMC 0,047\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB 10 MHz do 500 MHz CMC 0,047\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,024\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,092\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB 10 GHz do 18 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB 9 kHz do 300 kHz CMC 0,071\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB 300 kHz do 10 MHz CMC 0,071\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB 10 MHz do 500 MHz CMC 0,071\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,034\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB 10 GHz do 18 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB 9 kHz do 300 kHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB 300 kHz do 10 MHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB 10 MHz do 500 MHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,069\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB 10 GHz do 18 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB 9 kHz do 300 kHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB 300 kHz do 10 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB 10 MHz do 500 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB 10 GHz do 18 GHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB 9 kHz do 300 kHz CMC 9,6°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB 300 kHz do 10 MHz CMC 5,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB 10 MHz do 500 MHz CMC 3,7°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 2,6°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 3,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB 10 GHz do 18 GHz CMC 3,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB 9 kHz do 300 kHz CMC 1,9°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB 300 kHz do 10 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB 10 MHz do 500 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,60°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB 10 GHz do 18 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB 9 kHz do 300 kHz CMC 0,86°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB 300 kHz do 10 MHz CMC 0,81°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB 10 MHz do 500 MHz CMC 0,80°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,34°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,80°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB 10 GHz do 18 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB 9 kHz do 300 kHz CMC 0,55°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB 300 kHz do 10 MHz CMC 0,55°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB 10 MHz do 500 MHz CMC 0,55°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,24°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,71°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB 10 GHz do 18 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB 9 kHz do 300 kHz CMC 0,31°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB 300 kHz do 10 MHz CMC 0,31°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB 10 MHz do 500 MHz CMC 0,31°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,16°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,59°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB 10 GHz do 18 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB 9 kHz do 300 kHz CMC 0,47°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB 300 kHz do 10 MHz CMC 0,47°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB 10 MHz do 500 MHz CMC 0,47°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,23°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,67°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB 10 GHz do 18 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB 9 kHz do 300 kHz CMC 0,75°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB 300 kHz do 10 MHz CMC 0,75°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB 10 MHz do 500 MHz CMC 0,75°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,49°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,95°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB 10 GHz do 18 GHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB 9 kHz do 300 kHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB 300 kHz do 10 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB 10 MHz do 500 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,57°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB 10 GHz do 18 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -80,0 dB 9 kHz do 30 kHz CMC 0,54\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -80,0 dB 30 kHz do 1,3 GHz CMC 0,37\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -80,0 dB 1,3 GHz do 3 GHz CMC 0,40\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -60,0 dB 9 kHz do 30 kHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -60,0 dB 30 kHz do 1,3 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -60,0 dB 1,3 GHz do 3 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -40,0 dB 9 kHz do 30 kHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -40,0 dB 30 kHz do 1,3 GHz CMC 0,10\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -40,0 dB 1,3 GHz do 3 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -20,0 dB 9 kHz do 30 kHz CMC 0,081\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -20,0 dB 30 kHz do 1,3 GHz CMC 0,073\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -20,0 dB 1,3 GHz do 3 GHz CMC 0,093\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 0,0 dB 9 kHz do 30 kHz CMC 0,057\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 0,0 dB 30 kHz do 1,3 GHz CMC 0,050\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 0,0 dB 1,3 GHz do 3 GHz CMC 0,070\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 20,0 dB 9 kHz do 30 kHz CMC 0,081\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 20,0 dB 30 kHz do 1,3 GHz CMC 0,074\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 20,0 dB 1,3 GHz do 3 GHz CMC 0,093\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 40,0 dB 9 kHz do 30 kHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 40,0 dB 30 kHz do 1,3 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 40,0 dB 1,3 GHz do 3 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 60,0 dB 9 kHz do 30 kHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 60,0 dB 30 kHz do 1,3 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 60,0 dB 1,3 GHz do 3 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -80,0 dB 9 kHz do 30 kHz CMC 3,7°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -80,0 dB 30 kHz do 1,3 GHz CMC 2,7°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -80,0 dB 1,3 GHz do 3 GHz CMC 2,9°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -60,0 dB 9 kHz do 30 kHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -60,0 dB 30 kHz do 1,3 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -60,0 dB 1,3 GHz do 3 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -40,0 dB 9 kHz do 30 kHz CMC 0,83°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -40,0 dB 30 kHz do 1,3 GHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -40,0 dB 1,3 GHz do 3 GHz CMC 0,81°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -20,0 dB 9 kHz do 30 kHz CMC 0,54°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -20,0 dB 30 kHz do 1,3 GHz CMC 0,49°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -20,0 dB 1,3 GHz do 3 GHz CMC 0,62°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 0,0 dB 9 kHz do 30 kHz CMC 0,38°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 0,0 dB 30 kHz do 1,3 GHz CMC 0,33°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 0,0 dB 1,3 GHz do 3 GHz CMC 0,47°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 20,0 dB 9 kHz do 30 kHz CMC 0,54°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 20,0 dB 30 kHz do 1,3 GHz CMC 0,50°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 20,0 dB 1,3 GHz do 3 GHz CMC 0,63°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 40,0 dB 9 kHz do 30 kHz CMC 0,80°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 40,0 dB 30 kHz do 1,3 GHz CMC 0,69°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 40,0 dB 1,3 GHz do 3 GHz CMC 0,84°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 60,0 dB 9 kHz do 30 kHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 60,0 dB 30 kHz do 1,3 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 60,0 dB 1,3 GHz do 3 GHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 9 kHz do 10 MHz CMC 0,75\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 10 MHz do 45 MHz CMC 0,55\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 45 MHz do 500 MHz CMC 0,55\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 0,43\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 0,46\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 10 GHz do 20 GHz CMC 0,49\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 20 GHz do 26,5 GHz CMC 0,52\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 9 kHz do 10 MHz CMC 0,24\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 10 MHz do 45 MHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 45 MHz do 500 MHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 10 GHz do 20 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 20 GHz do 26,5 GHz CMC 0,23\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 9 kHz do 10 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 10 MHz do 45 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 45 MHz do 500 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 10 GHz do 20 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 20 GHz do 26,5 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 9 kHz do 10 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 10 MHz do 45 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 45 MHz do 500 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 10 GHz do 20 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 20 GHz do 26,5 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 9 kHz do 10 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 10 MHz do 45 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 45 MHz do 500 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,092\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 10 GHz do 20 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 20 GHz do 26,5 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 9 kHz do 10 MHz CMC 0,099\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 10 MHz do 45 MHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 45 MHz do 500 MHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,097\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 10 GHz do 20 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 20 GHz do 26,5 GHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 9 kHz do 10 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 10 MHz do 45 MHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 45 MHz do 500 MHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 10 GHz do 20 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 20 GHz do 26,5 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 9 kHz do 10 MHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 10 MHz do 45 MHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 45 MHz do 500 MHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 10 GHz do 20 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 20 GHz do 26,5 GHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 9 kHz do 10 MHz CMC 5,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 10 MHz do 45 MHz CMC 3,8°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 45 MHz do 500 MHz CMC 3,8°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 3,0°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 3,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 10 GHz do 20 GHz CMC 3,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 20 GHz do 26,5 GHz CMC 3,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 9 kHz do 10 MHz CMC 1,6°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 10 MHz do 45 MHz CMC 11,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 45 MHz do 500 MHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,96°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 10 GHz do 20 GHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 20 GHz do 26,5 GHz CMC 1,6°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 9 kHz do 10 MHz CMC 0,94°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 10 MHz do 45 MHz CMC 0,93°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 45 MHz do 500 MHz CMC 0,93°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,71°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,86°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 10 GHz do 20 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 20 GHz do 26,5 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 9 kHz do 10 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 10 MHz do 45 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 45 MHz do 500 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,53°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,71°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 10 GHz do 20 GHz CMC 0,94°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 20 GHz do 26,5 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 9 kHz do 10 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 10 MHz do 45 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 45 MHz do 500 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,61°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 10 GHz do 20 GHz CMC 0,84°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 20 GHz do 26,5 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 9 kHz do 10 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 10 MHz do 45 MHz CMC 0,67°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 45 MHz do 500 MHz CMC 0,69°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,69°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,80°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 10 GHz do 20 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 20 GHz do 26,5 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 9 kHz do 10 MHz CMC 0,93°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 10 MHz do 45 MHz CMC 0,74°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 45 MHz do 500 MHz CMC 0,76°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,76°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,87°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 10 GHz do 20 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 20 GHz do 26,5 GHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 9 kHz do 10 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 10 MHz do 45 MHz CMC 0,82°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 45 MHz do 500 MHz CMC 0,83°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,83°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0,95°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 10 GHz do 20 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 20 GHz do 26,5 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 9 kHz do 10 MHz CMC 0,75\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 10 MHz do 45 MHz CMC 0,55\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 45 MHz do 500 MHz CMC 0,55\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 0,41\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 0,42\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 10 GHz do 20 GHz CMC 0,45\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 20 GHz do 35 GHz CMC 0,48\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 35 GHz do 44 GHz CMC 0,71\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 44 GHz do 50 GHz CMC 1,9\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 9 kHz do 10 MHz CMC 0,24\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 10 MHz do 45 MHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 45 MHz do 500 MHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 10 GHz do 20 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 20 GHz do 35 GHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 35 GHz do 44 GHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 44 GHz do 50 GHz CMC 0,39\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 9 kHz do 10 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 10 MHz do 45 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 45 MHz do 500 MHz CMC 0,086\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,093\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 10 GHz do 20 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 20 GHz do 35 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 35 GHz do 44 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 44 GHz do 50 GHz CMC 0,23\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 9 kHz do 10 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 10 MHz do 45 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 45 MHz do 500 MHz CMC 0,065\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,080\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 10 GHz do 20 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 20 GHz do 35 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 35 GHz do 44 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 44 GHz do 50 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 9 kHz do 10 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 10 MHz do 45 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 45 MHz do 500 MHz CMC 0,056\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,052\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 10 GHz do 20 GHz CMC 0,089\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 20 GHz do 35 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 35 GHz do 44 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 44 GHz do 50 GHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 9 kHz do 10 MHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 10 MHz do 45 MHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 45 MHz do 500 MHz CMC 0,064\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,083\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,92\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 10 GHz do 20 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 20 GHz do 35 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 35 GHz do 44 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 44 GHz do 50 GHz CMC 0,23\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 9 kHz do 10 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 10 MHz do 45 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 45 MHz do 500 MHz CMC 0,075\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,095\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 10 GHz do 20 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 20 GHz do 35 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 35 GHz do 44 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 44 GHz do 50 GHz CMC 0,24\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 9 kHz do 10 MHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 10 MHz do 45 MHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 45 MHz do 500 MHz CMC 0,086\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 10 GHz do 20 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 20 GHz do 35 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 35 GHz do 44 GHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 44 GHz do 50 GHz CMC 0,25\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 9 kHz do 10 MHz CMC 5,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 10 MHz do 45 MHz CMC 3,8°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 45 MHz do 500 MHz CMC 3,8°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 2,8°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 2,9°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 10 GHz do 20 GHz CMC 3,0°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 20 GHz do 35 GHz CMC 3,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 35 GHz do 44 GHz CMC 4,9°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 44 GHz do 50 GHz CMC 14°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 9 kHz do 10 MHz CMC 1,6°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 10 MHz do 45 MHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 45 MHz do 500 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,79°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 0,88°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 10 GHz do 20 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 20 GHz do 35 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 35 GHz do 44 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 44 GHz do 50 GHz CMC 2,7°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 9 kHz do 10 MHz CMC 0,94°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 10 MHz do 45 MHz CMC 0,93°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 45 MHz do 500 MHz CMC 0,57°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,53°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,62°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 10 GHz do 20 GHz CMC 0,77°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 20 GHz do 35 GHz CMC 0,97°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 35 GHz do 44 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 44 GHz do 50 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 9 kHz do 10 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 10 MHz do 45 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 45 MHz do 500 MHz CMC 0,43°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,53°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 10 GHz do 20 GHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 20 GHz do 35 GHz CMC 0,88°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 35 GHz do 44 GHz CMC 0,90°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 44 GHz do 50 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 9 kHz do 10 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 10 MHz do 45 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 45 MHz do 500 MHz CMC 0,37°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,35°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 10 GHz do 20 GHz CMC 0,59°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 20 GHz do 35 GHz CMC 0,81°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 35 GHz do 44 GHz CMC 0,82°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 44 GHz do 50 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 9 kHz do 10 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 10 MHz do 45 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 45 MHz do 500 MHz CMC 0,42°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,59°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,63°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 10 GHz do 20 GHz CMC 0,77°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 20 GHz do 35 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 35 GHz do 44 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 44 GHz do 50 GHz CMC 1,6°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 9 kHz do 10 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 10 MHz do 45 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 45 MHz do 500 MHz CMC 0,50°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,67°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,70°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 10 GHz do 20 GHz CMC 0,84°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 20 GHz do 35 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 35 GHz do 44 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 44 GHz do 50 GHz CMC 1,7°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 9 kHz do 10 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 10 MHz do 45 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 45 MHz do 500 MHz CMC 0,57°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,74°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0.77°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 10 GHz do 20 GHz CMC 0,92°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 20 GHz do 35 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 35 GHz do 44 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 44 GHz do 50 GHz CMC 1,7°\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/34\nLMEEiO/48","norm_bases":["LMEEiO/34","LMEEiO/48"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"RF electrical quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Tłumiki stałe\nTłumiki regulowane\nFiltry\nSprzęgacze kierunkowe\nPrzełączniki\nAnalizatory systemów antenowych i kablowych\nWzmacniacze\n- transmisja S21 / S12 Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\n9 kHz do 50 GHz -80 dB do 60 dB CMC Matryca CMC na nast. str.\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB 9 kHz do 300 kHz CMC 1,4\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB 300 kHz do 10 MHz CMC 0,74\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB 10 MHz do 500 MHz CMC 0,53\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 0,38\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 0,45\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -80,0 dB 10 GHz do 18 GHz CMC 0,51\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB 9 kHz do 300 kHz CMC 0,28\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB 300 kHz do 10 MHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB 10 MHz do 500 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,090\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -60,0 dB 10 GHz do 18 GHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB 9 kHz do 300 kHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB 300 kHz do 10 MHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB 10 MHz do 500 MHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,050\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -40,0 dB 10 GHz do 18 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB 9 kHz do 300 kHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB 300 kHz do 10 MHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB 10 MHz do 500 MHz CMC 0,078\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = -20,0 dB 10 GHz do 18 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB 9 kHz do 300 kHz CMC 0,047\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB 300 kHz do 10 MHz CMC 0,047\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB 10 MHz do 500 MHz CMC 0,047\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,024\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,092\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 0,0 dB 10 GHz do 18 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB 9 kHz do 300 kHz CMC 0,071\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB 300 kHz do 10 MHz CMC 0,071\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB 10 MHz do 500 MHz CMC 0,071\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,034\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 20,0 dB 10 GHz do 18 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB 9 kHz do 300 kHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB 300 kHz do 10 MHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB 10 MHz do 500 MHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,069\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 40,0 dB 10 GHz do 18 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB 9 kHz do 300 kHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB 300 kHz do 10 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB 10 MHz do 500 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 50 Ω); S21 / S12 = 60,0 dB 10 GHz do 18 GHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB 9 kHz do 300 kHz CMC 9,6°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB 300 kHz do 10 MHz CMC 5,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB 10 MHz do 500 MHz CMC 3,7°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 2,6°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 3,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -80,0 dB 10 GHz do 18 GHz CMC 3,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB 9 kHz do 300 kHz CMC 1,9°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB 300 kHz do 10 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB 10 MHz do 500 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,60°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -60,0 dB 10 GHz do 18 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB 9 kHz do 300 kHz CMC 0,86°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB 300 kHz do 10 MHz CMC 0,81°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB 10 MHz do 500 MHz CMC 0,80°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,34°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,80°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -40,0 dB 10 GHz do 18 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB 9 kHz do 300 kHz CMC 0,55°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB 300 kHz do 10 MHz CMC 0,55°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB 10 MHz do 500 MHz CMC 0,55°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,24°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,71°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = -20,0 dB 10 GHz do 18 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB 9 kHz do 300 kHz CMC 0,31°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB 300 kHz do 10 MHz CMC 0,31°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB 10 MHz do 500 MHz CMC 0,31°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,16°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,59°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 0,0 dB 10 GHz do 18 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB 9 kHz do 300 kHz CMC 0,47°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB 300 kHz do 10 MHz CMC 0,47°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB 10 MHz do 500 MHz CMC 0,47°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,23°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,67°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 20,0 dB 10 GHz do 18 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB 9 kHz do 300 kHz CMC 0,75°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB 300 kHz do 10 MHz CMC 0,75°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB 10 MHz do 500 MHz CMC 0,75°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,49°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,95°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 40,0 dB 10 GHz do 18 GHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB 9 kHz do 300 kHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB 300 kHz do 10 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB 10 MHz do 500 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,57°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 50 Ω); S21 / S12 = 60,0 dB 10 GHz do 18 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -80,0 dB 9 kHz do 30 kHz CMC 0,54\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -80,0 dB 30 kHz do 1,3 GHz CMC 0,37\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -80,0 dB 1,3 GHz do 3 GHz CMC 0,40\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -60,0 dB 9 kHz do 30 kHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -60,0 dB 30 kHz do 1,3 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -60,0 dB 1,3 GHz do 3 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -40,0 dB 9 kHz do 30 kHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -40,0 dB 30 kHz do 1,3 GHz CMC 0,10\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -40,0 dB 1,3 GHz do 3 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -20,0 dB 9 kHz do 30 kHz CMC 0,081\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -20,0 dB 30 kHz do 1,3 GHz CMC 0,073\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = -20,0 dB 1,3 GHz do 3 GHz CMC 0,093\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 0,0 dB 9 kHz do 30 kHz CMC 0,057\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 0,0 dB 30 kHz do 1,3 GHz CMC 0,050\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 0,0 dB 1,3 GHz do 3 GHz CMC 0,070\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 20,0 dB 9 kHz do 30 kHz CMC 0,081\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 20,0 dB 30 kHz do 1,3 GHz CMC 0,074\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 20,0 dB 1,3 GHz do 3 GHz CMC 0,093\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 40,0 dB 9 kHz do 30 kHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 40,0 dB 30 kHz do 1,3 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 40,0 dB 1,3 GHz do 3 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 60,0 dB 9 kHz do 30 kHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 60,0 dB 30 kHz do 1,3 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – moduł (złącze N 75 Ω); S21 / S12 = 60,0 dB 1,3 GHz do 3 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -80,0 dB 9 kHz do 30 kHz CMC 3,7°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -80,0 dB 30 kHz do 1,3 GHz CMC 2,7°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -80,0 dB 1,3 GHz do 3 GHz CMC 2,9°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -60,0 dB 9 kHz do 30 kHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -60,0 dB 30 kHz do 1,3 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -60,0 dB 1,3 GHz do 3 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -40,0 dB 9 kHz do 30 kHz CMC 0,83°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -40,0 dB 30 kHz do 1,3 GHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -40,0 dB 1,3 GHz do 3 GHz CMC 0,81°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -20,0 dB 9 kHz do 30 kHz CMC 0,54°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -20,0 dB 30 kHz do 1,3 GHz CMC 0,49°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = -20,0 dB 1,3 GHz do 3 GHz CMC 0,62°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 0,0 dB 9 kHz do 30 kHz CMC 0,38°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 0,0 dB 30 kHz do 1,3 GHz CMC 0,33°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 0,0 dB 1,3 GHz do 3 GHz CMC 0,47°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 20,0 dB 9 kHz do 30 kHz CMC 0,54°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 20,0 dB 30 kHz do 1,3 GHz CMC 0,50°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 20,0 dB 1,3 GHz do 3 GHz CMC 0,63°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 40,0 dB 9 kHz do 30 kHz CMC 0,80°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 40,0 dB 30 kHz do 1,3 GHz CMC 0,69°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 40,0 dB 1,3 GHz do 3 GHz CMC 0,84°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 60,0 dB 9 kHz do 30 kHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 60,0 dB 30 kHz do 1,3 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze N 75 Ω); S21 / S12 = 60,0 dB 1,3 GHz do 3 GHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 9 kHz do 10 MHz CMC 0,75\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 10 MHz do 45 MHz CMC 0,55\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 45 MHz do 500 MHz CMC 0,55\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 0,43\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 0,46\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 10 GHz do 20 GHz CMC 0,49\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -80,0 dB 20 GHz do 26,5 GHz CMC 0,52\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 9 kHz do 10 MHz CMC 0,24\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 10 MHz do 45 MHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 45 MHz do 500 MHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 10 GHz do 20 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -60,0 dB 20 GHz do 26,5 GHz CMC 0,23\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 9 kHz do 10 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 10 MHz do 45 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 45 MHz do 500 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 10 GHz do 20 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -40,0 dB 20 GHz do 26,5 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 9 kHz do 10 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 10 MHz do 45 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 45 MHz do 500 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 10 GHz do 20 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = -20,0 dB 20 GHz do 26,5 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 9 kHz do 10 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 10 MHz do 45 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 45 MHz do 500 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,092\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 10 GHz do 20 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 0,0 dB 20 GHz do 26,5 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 9 kHz do 10 MHz CMC 0,099\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 10 MHz do 45 MHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 45 MHz do 500 MHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,097\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 10 GHz do 20 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 20,0 dB 20 GHz do 26,5 GHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 9 kHz do 10 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 10 MHz do 45 MHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 45 MHz do 500 MHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 10 GHz do 20 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 40,0 dB 20 GHz do 26,5 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 9 kHz do 10 MHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 10 MHz do 45 MHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 45 MHz do 500 MHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 10 GHz do 20 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 3,5 mm); S21 / S12 = 60,0 dB 20 GHz do 26,5 GHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 9 kHz do 10 MHz CMC 5,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 10 MHz do 45 MHz CMC 3,8°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 45 MHz do 500 MHz CMC 3,8°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 3,0°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 3,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 10 GHz do 20 GHz CMC 3,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -80,0 dB 20 GHz do 26,5 GHz CMC 3,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 9 kHz do 10 MHz CMC 1,6°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 10 MHz do 45 MHz CMC 11,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 45 MHz do 500 MHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,96°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 10 GHz do 20 GHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -60,0 dB 20 GHz do 26,5 GHz CMC 1,6°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 9 kHz do 10 MHz CMC 0,94°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 10 MHz do 45 MHz CMC 0,93°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 45 MHz do 500 MHz CMC 0,93°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,71°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,86°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 10 GHz do 20 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -40,0 dB 20 GHz do 26,5 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 9 kHz do 10 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 10 MHz do 45 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 45 MHz do 500 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,53°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,71°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 10 GHz do 20 GHz CMC 0,94°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = -20,0 dB 20 GHz do 26,5 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 9 kHz do 10 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 10 MHz do 45 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 45 MHz do 500 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,61°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 10 GHz do 20 GHz CMC 0,84°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 0,0 dB 20 GHz do 26,5 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 9 kHz do 10 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 10 MHz do 45 MHz CMC 0,67°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 45 MHz do 500 MHz CMC 0,69°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,69°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,80°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 10 GHz do 20 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 20,0 dB 20 GHz do 26,5 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 9 kHz do 10 MHz CMC 0,93°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 10 MHz do 45 MHz CMC 0,74°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 45 MHz do 500 MHz CMC 0,76°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,76°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,87°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 10 GHz do 20 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 40,0 dB 20 GHz do 26,5 GHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 9 kHz do 10 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 10 MHz do 45 MHz CMC 0,82°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 45 MHz do 500 MHz CMC 0,83°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,83°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0,95°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 10 GHz do 20 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 3,5 mm); S21 / S12 = 60,0 dB 20 GHz do 26,5 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 9 kHz do 10 MHz CMC 0,75\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 10 MHz do 45 MHz CMC 0,55\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 45 MHz do 500 MHz CMC 0,55\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 0,41\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 0,42\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 10 GHz do 20 GHz CMC 0,45\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 20 GHz do 35 GHz CMC 0,48\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 35 GHz do 44 GHz CMC 0,71\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -80,0 dB 44 GHz do 50 GHz CMC 1,9\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 9 kHz do 10 MHz CMC 0,24\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 10 MHz do 45 MHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 45 MHz do 500 MHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 10 GHz do 20 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 20 GHz do 35 GHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 35 GHz do 44 GHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -60,0 dB 44 GHz do 50 GHz CMC 0,39\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 9 kHz do 10 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 10 MHz do 45 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 45 MHz do 500 MHz CMC 0,086\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,093\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 10 GHz do 20 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 20 GHz do 35 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 35 GHz do 44 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -40,0 dB 44 GHz do 50 GHz CMC 0,23\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 9 kHz do 10 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 10 MHz do 45 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 45 MHz do 500 MHz CMC 0,065\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,080\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 10 GHz do 20 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 20 GHz do 35 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 35 GHz do 44 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = -20,0 dB 44 GHz do 50 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 9 kHz do 10 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 10 MHz do 45 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 45 MHz do 500 MHz CMC 0,056\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,052\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 10 GHz do 20 GHz CMC 0,089\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 20 GHz do 35 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 35 GHz do 44 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 0,0 dB 44 GHz do 50 GHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 9 kHz do 10 MHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 10 MHz do 45 MHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 45 MHz do 500 MHz CMC 0,064\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,083\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,92\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 10 GHz do 20 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 20 GHz do 35 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 35 GHz do 44 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 20,0 dB 44 GHz do 50 GHz CMC 0,23\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 9 kHz do 10 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 10 MHz do 45 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 45 MHz do 500 MHz CMC 0,075\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,095\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 10 GHz do 20 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 20 GHz do 35 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 35 GHz do 44 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 40,0 dB 44 GHz do 50 GHz CMC 0,24\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 9 kHz do 10 MHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 10 MHz do 45 MHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 45 MHz do 500 MHz CMC 0,086\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 10 GHz do 20 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 20 GHz do 35 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 35 GHz do 44 GHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – moduł (złącze 2,4 mm); S21 / S12 = 60,0 dB 44 GHz do 50 GHz CMC 0,25\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 9 kHz do 10 MHz CMC 5,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 10 MHz do 45 MHz CMC 3,8°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 45 MHz do 500 MHz CMC 3,8°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 2,8°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 2,9°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 10 GHz do 20 GHz CMC 3,0°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 20 GHz do 35 GHz CMC 3,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 35 GHz do 44 GHz CMC 4,9°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -80,0 dB 44 GHz do 50 GHz CMC 14°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 9 kHz do 10 MHz CMC 1,6°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 10 MHz do 45 MHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 45 MHz do 500 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,79°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 0,88°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 10 GHz do 20 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 20 GHz do 35 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 35 GHz do 44 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -60,0 dB 44 GHz do 50 GHz CMC 2,7°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 9 kHz do 10 MHz CMC 0,94°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 10 MHz do 45 MHz CMC 0,93°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 45 MHz do 500 MHz CMC 0,57°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,53°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,62°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 10 GHz do 20 GHz CMC 0,77°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 20 GHz do 35 GHz CMC 0,97°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 35 GHz do 44 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -40,0 dB 44 GHz do 50 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 9 kHz do 10 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 10 MHz do 45 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 45 MHz do 500 MHz CMC 0,43°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,53°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 10 GHz do 20 GHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 20 GHz do 35 GHz CMC 0,88°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 35 GHz do 44 GHz CMC 0,90°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = -20,0 dB 44 GHz do 50 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 9 kHz do 10 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 10 MHz do 45 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 45 MHz do 500 MHz CMC 0,37°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,35°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 10 GHz do 20 GHz CMC 0,59°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 20 GHz do 35 GHz CMC 0,81°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 35 GHz do 44 GHz CMC 0,82°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 0,0 dB 44 GHz do 50 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 9 kHz do 10 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 10 MHz do 45 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 45 MHz do 500 MHz CMC 0,42°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,59°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,63°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 10 GHz do 20 GHz CMC 0,77°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 20 GHz do 35 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 35 GHz do 44 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 20,0 dB 44 GHz do 50 GHz CMC 1,6°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 9 kHz do 10 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 10 MHz do 45 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 45 MHz do 500 MHz CMC 0,50°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,67°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,70°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 10 GHz do 20 GHz CMC 0,84°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 20 GHz do 35 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 35 GHz do 44 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 40,0 dB 44 GHz do 50 GHz CMC 1,7°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 9 kHz do 10 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 10 MHz do 45 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 45 MHz do 500 MHz CMC 0,57°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,74°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0.77°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 10 GHz do 20 GHz CMC 0,92°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 20 GHz do 35 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 35 GHz do 44 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (złącze 2,4 mm); S21 / S12 = 60,0 dB 44 GHz do 50 GHz CMC 1,7°\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/34\nLMEEiO/48 Tlumiki stale\nTlumiki regulowane\nFiltry\nSprzegacze kierunkowe\nPrzelaczniki\nAnalizatory systemow antenowych i kablowych\nWzmacniacze\n- transmisja S21 / S12 Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\n9 kHz do 50 GHz -80 dB do 60 dB CMC Matryca CMC na nast. str.\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -80,0 dB 9 kHz do 300 kHz CMC 1,4\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -80,0 dB 300 kHz do 10 MHz CMC 0,74\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -80,0 dB 10 MHz do 500 MHz CMC 0,53\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 0,38\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 0,45\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -80,0 dB 10 GHz do 18 GHz CMC 0,51\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -60,0 dB 9 kHz do 300 kHz CMC 0,28\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -60,0 dB 300 kHz do 10 MHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -60,0 dB 10 MHz do 500 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,090\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -60,0 dB 10 GHz do 18 GHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -40,0 dB 9 kHz do 300 kHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -40,0 dB 300 kHz do 10 MHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -40,0 dB 10 MHz do 500 MHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,050\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -40,0 dB 10 GHz do 18 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -20,0 dB 9 kHz do 300 kHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -20,0 dB 300 kHz do 10 MHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -20,0 dB 10 MHz do 500 MHz CMC 0,078\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = -20,0 dB 10 GHz do 18 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 0,0 dB 9 kHz do 300 kHz CMC 0,047\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 0,0 dB 300 kHz do 10 MHz CMC 0,047\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 0,0 dB 10 MHz do 500 MHz CMC 0,047\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,024\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,092\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 0,0 dB 10 GHz do 18 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 20,0 dB 9 kHz do 300 kHz CMC 0,071\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 20,0 dB 300 kHz do 10 MHz CMC 0,071\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 20,0 dB 10 MHz do 500 MHz CMC 0,071\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,034\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 20,0 dB 10 GHz do 18 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 40,0 dB 9 kHz do 300 kHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 40,0 dB 300 kHz do 10 MHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 40,0 dB 10 MHz do 500 MHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,069\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 40,0 dB 10 GHz do 18 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 60,0 dB 9 kHz do 300 kHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 60,0 dB 300 kHz do 10 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 60,0 dB 10 MHz do 500 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 50 Ω); S21 / S12 = 60,0 dB 10 GHz do 18 GHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -80,0 dB 9 kHz do 300 kHz CMC 9,6°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -80,0 dB 300 kHz do 10 MHz CMC 5,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -80,0 dB 10 MHz do 500 MHz CMC 3,7°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 2,6°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 3,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -80,0 dB 10 GHz do 18 GHz CMC 3,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -60,0 dB 9 kHz do 300 kHz CMC 1,9°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -60,0 dB 300 kHz do 10 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -60,0 dB 10 MHz do 500 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,60°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -60,0 dB 10 GHz do 18 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -40,0 dB 9 kHz do 300 kHz CMC 0,86°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -40,0 dB 300 kHz do 10 MHz CMC 0,81°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -40,0 dB 10 MHz do 500 MHz CMC 0,80°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,34°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,80°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -40,0 dB 10 GHz do 18 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -20,0 dB 9 kHz do 300 kHz CMC 0,55°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -20,0 dB 300 kHz do 10 MHz CMC 0,55°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -20,0 dB 10 MHz do 500 MHz CMC 0,55°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,24°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,71°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = -20,0 dB 10 GHz do 18 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 0,0 dB 9 kHz do 300 kHz CMC 0,31°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 0,0 dB 300 kHz do 10 MHz CMC 0,31°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 0,0 dB 10 MHz do 500 MHz CMC 0,31°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,16°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,59°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 0,0 dB 10 GHz do 18 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 20,0 dB 9 kHz do 300 kHz CMC 0,47°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 20,0 dB 300 kHz do 10 MHz CMC 0,47°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 20,0 dB 10 MHz do 500 MHz CMC 0,47°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,23°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,67°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 20,0 dB 10 GHz do 18 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 40,0 dB 9 kHz do 300 kHz CMC 0,75°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 40,0 dB 300 kHz do 10 MHz CMC 0,75°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 40,0 dB 10 MHz do 500 MHz CMC 0,75°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,49°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,95°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 40,0 dB 10 GHz do 18 GHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 60,0 dB 9 kHz do 300 kHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 60,0 dB 300 kHz do 10 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 60,0 dB 10 MHz do 500 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,57°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 50 Ω); S21 / S12 = 60,0 dB 10 GHz do 18 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = -80,0 dB 9 kHz do 30 kHz CMC 0,54\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = -80,0 dB 30 kHz do 1,3 GHz CMC 0,37\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = -80,0 dB 1,3 GHz do 3 GHz CMC 0,40\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = -60,0 dB 9 kHz do 30 kHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = -60,0 dB 30 kHz do 1,3 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = -60,0 dB 1,3 GHz do 3 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = -40,0 dB 9 kHz do 30 kHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = -40,0 dB 30 kHz do 1,3 GHz CMC 0,10\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = -40,0 dB 1,3 GHz do 3 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = -20,0 dB 9 kHz do 30 kHz CMC 0,081\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = -20,0 dB 30 kHz do 1,3 GHz CMC 0,073\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = -20,0 dB 1,3 GHz do 3 GHz CMC 0,093\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = 0,0 dB 9 kHz do 30 kHz CMC 0,057\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = 0,0 dB 30 kHz do 1,3 GHz CMC 0,050\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = 0,0 dB 1,3 GHz do 3 GHz CMC 0,070\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = 20,0 dB 9 kHz do 30 kHz CMC 0,081\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = 20,0 dB 30 kHz do 1,3 GHz CMC 0,074\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = 20,0 dB 1,3 GHz do 3 GHz CMC 0,093\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = 40,0 dB 9 kHz do 30 kHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = 40,0 dB 30 kHz do 1,3 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = 40,0 dB 1,3 GHz do 3 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = 60,0 dB 9 kHz do 30 kHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = 60,0 dB 30 kHz do 1,3 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – modul (zlacze N 75 Ω); S21 / S12 = 60,0 dB 1,3 GHz do 3 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = -80,0 dB 9 kHz do 30 kHz CMC 3,7°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = -80,0 dB 30 kHz do 1,3 GHz CMC 2,7°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = -80,0 dB 1,3 GHz do 3 GHz CMC 2,9°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = -60,0 dB 9 kHz do 30 kHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = -60,0 dB 30 kHz do 1,3 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = -60,0 dB 1,3 GHz do 3 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = -40,0 dB 9 kHz do 30 kHz CMC 0,83°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = -40,0 dB 30 kHz do 1,3 GHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = -40,0 dB 1,3 GHz do 3 GHz CMC 0,81°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = -20,0 dB 9 kHz do 30 kHz CMC 0,54°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = -20,0 dB 30 kHz do 1,3 GHz CMC 0,49°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = -20,0 dB 1,3 GHz do 3 GHz CMC 0,62°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = 0,0 dB 9 kHz do 30 kHz CMC 0,38°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = 0,0 dB 30 kHz do 1,3 GHz CMC 0,33°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = 0,0 dB 1,3 GHz do 3 GHz CMC 0,47°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = 20,0 dB 9 kHz do 30 kHz CMC 0,54°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = 20,0 dB 30 kHz do 1,3 GHz CMC 0,50°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = 20,0 dB 1,3 GHz do 3 GHz CMC 0,63°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = 40,0 dB 9 kHz do 30 kHz CMC 0,80°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = 40,0 dB 30 kHz do 1,3 GHz CMC 0,69°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = 40,0 dB 1,3 GHz do 3 GHz CMC 0,84°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = 60,0 dB 9 kHz do 30 kHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = 60,0 dB 30 kHz do 1,3 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze N 75 Ω); S21 / S12 = 60,0 dB 1,3 GHz do 3 GHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -80,0 dB 9 kHz do 10 MHz CMC 0,75\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -80,0 dB 10 MHz do 45 MHz CMC 0,55\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -80,0 dB 45 MHz do 500 MHz CMC 0,55\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 0,43\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 0,46\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -80,0 dB 10 GHz do 20 GHz CMC 0,49\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -80,0 dB 20 GHz do 26,5 GHz CMC 0,52\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -60,0 dB 9 kHz do 10 MHz CMC 0,24\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -60,0 dB 10 MHz do 45 MHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -60,0 dB 45 MHz do 500 MHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -60,0 dB 10 GHz do 20 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -60,0 dB 20 GHz do 26,5 GHz CMC 0,23\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -40,0 dB 9 kHz do 10 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -40,0 dB 10 MHz do 45 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -40,0 dB 45 MHz do 500 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -40,0 dB 10 GHz do 20 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -40,0 dB 20 GHz do 26,5 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -20,0 dB 9 kHz do 10 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -20,0 dB 10 MHz do 45 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -20,0 dB 45 MHz do 500 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -20,0 dB 10 GHz do 20 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = -20,0 dB 20 GHz do 26,5 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 0,0 dB 9 kHz do 10 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 0,0 dB 10 MHz do 45 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 0,0 dB 45 MHz do 500 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,092\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 0,0 dB 10 GHz do 20 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 0,0 dB 20 GHz do 26,5 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 20,0 dB 9 kHz do 10 MHz CMC 0,099\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 20,0 dB 10 MHz do 45 MHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 20,0 dB 45 MHz do 500 MHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,097\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 20,0 dB 10 GHz do 20 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 20,0 dB 20 GHz do 26,5 GHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 40,0 dB 9 kHz do 10 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 40,0 dB 10 MHz do 45 MHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 40,0 dB 45 MHz do 500 MHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 40,0 dB 10 GHz do 20 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 40,0 dB 20 GHz do 26,5 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 60,0 dB 9 kHz do 10 MHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 60,0 dB 10 MHz do 45 MHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 60,0 dB 45 MHz do 500 MHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 60,0 dB 10 GHz do 20 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 3,5 mm); S21 / S12 = 60,0 dB 20 GHz do 26,5 GHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -80,0 dB 9 kHz do 10 MHz CMC 5,2°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -80,0 dB 10 MHz do 45 MHz CMC 3,8°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -80,0 dB 45 MHz do 500 MHz CMC 3,8°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 3,0°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 3,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -80,0 dB 10 GHz do 20 GHz CMC 3,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -80,0 dB 20 GHz do 26,5 GHz CMC 3,5°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -60,0 dB 9 kHz do 10 MHz CMC 1,6°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -60,0 dB 10 MHz do 45 MHz CMC 11,5°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -60,0 dB 45 MHz do 500 MHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,96°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -60,0 dB 10 GHz do 20 GHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -60,0 dB 20 GHz do 26,5 GHz CMC 1,6°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -40,0 dB 9 kHz do 10 MHz CMC 0,94°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -40,0 dB 10 MHz do 45 MHz CMC 0,93°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -40,0 dB 45 MHz do 500 MHz CMC 0,93°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,71°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,86°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -40,0 dB 10 GHz do 20 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -40,0 dB 20 GHz do 26,5 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -20,0 dB 9 kHz do 10 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -20,0 dB 10 MHz do 45 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -20,0 dB 45 MHz do 500 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,53°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,71°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -20,0 dB 10 GHz do 20 GHz CMC 0,94°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = -20,0 dB 20 GHz do 26,5 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 0,0 dB 9 kHz do 10 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 0,0 dB 10 MHz do 45 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 0,0 dB 45 MHz do 500 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,61°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 0,0 dB 10 GHz do 20 GHz CMC 0,84°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 0,0 dB 20 GHz do 26,5 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 20,0 dB 9 kHz do 10 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 20,0 dB 10 MHz do 45 MHz CMC 0,67°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 20,0 dB 45 MHz do 500 MHz CMC 0,69°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,69°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,80°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 20,0 dB 10 GHz do 20 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 20,0 dB 20 GHz do 26,5 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 40,0 dB 9 kHz do 10 MHz CMC 0,93°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 40,0 dB 10 MHz do 45 MHz CMC 0,74°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 40,0 dB 45 MHz do 500 MHz CMC 0,76°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,76°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,87°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 40,0 dB 10 GHz do 20 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 40,0 dB 20 GHz do 26,5 GHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 60,0 dB 9 kHz do 10 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 60,0 dB 10 MHz do 45 MHz CMC 0,82°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 60,0 dB 45 MHz do 500 MHz CMC 0,83°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,83°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0,95°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 60,0 dB 10 GHz do 20 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 3,5 mm); S21 / S12 = 60,0 dB 20 GHz do 26,5 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -80,0 dB 9 kHz do 10 MHz CMC 0,75\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -80,0 dB 10 MHz do 45 MHz CMC 0,55\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -80,0 dB 45 MHz do 500 MHz CMC 0,55\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 0,41\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 0,42\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -80,0 dB 10 GHz do 20 GHz CMC 0,45\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -80,0 dB 20 GHz do 35 GHz CMC 0,48\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -80,0 dB 35 GHz do 44 GHz CMC 0,71\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -80,0 dB 44 GHz do 50 GHz CMC 1,9\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -60,0 dB 9 kHz do 10 MHz CMC 0,24\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -60,0 dB 10 MHz do 45 MHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -60,0 dB 45 MHz do 500 MHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -60,0 dB 10 GHz do 20 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -60,0 dB 20 GHz do 35 GHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -60,0 dB 35 GHz do 44 GHz CMC 0,22\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -60,0 dB 44 GHz do 50 GHz CMC 0,39\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -40,0 dB 9 kHz do 10 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -40,0 dB 10 MHz do 45 MHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -40,0 dB 45 MHz do 500 MHz CMC 0,086\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,079\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,093\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -40,0 dB 10 GHz do 20 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -40,0 dB 20 GHz do 35 GHz CMC 0,15\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -40,0 dB 35 GHz do 44 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -40,0 dB 44 GHz do 50 GHz CMC 0,23\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -20,0 dB 9 kHz do 10 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -20,0 dB 10 MHz do 45 MHz CMC 0,098\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -20,0 dB 45 MHz do 500 MHz CMC 0,065\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,080\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -20,0 dB 10 GHz do 20 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -20,0 dB 20 GHz do 35 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -20,0 dB 35 GHz do 44 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = -20,0 dB 44 GHz do 50 GHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 0,0 dB 9 kHz do 10 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 0,0 dB 10 MHz do 45 MHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 0,0 dB 45 MHz do 500 MHz CMC 0,056\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,052\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,066\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 0,0 dB 10 GHz do 20 GHz CMC 0,089\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 0,0 dB 20 GHz do 35 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 0,0 dB 35 GHz do 44 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 0,0 dB 44 GHz do 50 GHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 20,0 dB 9 kHz do 10 MHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 20,0 dB 10 MHz do 45 MHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 20,0 dB 45 MHz do 500 MHz CMC 0,064\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,083\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,92\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 20,0 dB 10 GHz do 20 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 20,0 dB 20 GHz do 35 GHz CMC 0,16\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 20,0 dB 35 GHz do 44 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 20,0 dB 44 GHz do 50 GHz CMC 0,23\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 40,0 dB 9 kHz do 10 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 40,0 dB 10 MHz do 45 MHz CMC 0,20\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 40,0 dB 45 MHz do 500 MHz CMC 0,075\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,095\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 40,0 dB 10 GHz do 20 GHz CMC 0,13\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 40,0 dB 20 GHz do 35 GHz CMC 0,17\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 40,0 dB 35 GHz do 44 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 40,0 dB 44 GHz do 50 GHz CMC 0,24\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 60,0 dB 9 kHz do 10 MHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 60,0 dB 10 MHz do 45 MHz CMC 0,21\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 60,0 dB 45 MHz do 500 MHz CMC 0,086\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,11\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0,12\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 60,0 dB 10 GHz do 20 GHz CMC 0,14\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 60,0 dB 20 GHz do 35 GHz CMC 0,18\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 60,0 dB 35 GHz do 44 GHz CMC 0,19\nMatryca CMC – transmisja S21 / S12 – modul (zlacze 2,4 mm); S21 / S12 = 60,0 dB 44 GHz do 50 GHz CMC 0,25\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -80,0 dB 9 kHz do 10 MHz CMC 5,2°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -80,0 dB 10 MHz do 45 MHz CMC 3,8°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -80,0 dB 45 MHz do 500 MHz CMC 3,8°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -80,0 dB 500 MHz do 2 GHz CMC 2,8°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -80,0 dB 2 GHz do 10 GHz CMC 2,9°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -80,0 dB 10 GHz do 20 GHz CMC 3,0°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -80,0 dB 20 GHz do 35 GHz CMC 3,2°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -80,0 dB 35 GHz do 44 GHz CMC 4,9°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -80,0 dB 44 GHz do 50 GHz CMC 14°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -60,0 dB 9 kHz do 10 MHz CMC 1,6°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -60,0 dB 10 MHz do 45 MHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -60,0 dB 45 MHz do 500 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -60,0 dB 500 MHz do 2 GHz CMC 0,79°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -60,0 dB 2 GHz do 10 GHz CMC 0,88°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -60,0 dB 10 GHz do 20 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -60,0 dB 20 GHz do 35 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -60,0 dB 35 GHz do 44 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -60,0 dB 44 GHz do 50 GHz CMC 2,7°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -40,0 dB 9 kHz do 10 MHz CMC 0,94°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -40,0 dB 10 MHz do 45 MHz CMC 0,93°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -40,0 dB 45 MHz do 500 MHz CMC 0,57°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -40,0 dB 500 MHz do 2 GHz CMC 0,53°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -40,0 dB 2 GHz do 10 GHz CMC 0,62°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -40,0 dB 10 GHz do 20 GHz CMC 0,77°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -40,0 dB 20 GHz do 35 GHz CMC 0,97°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -40,0 dB 35 GHz do 44 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -40,0 dB 44 GHz do 50 GHz CMC 1,5°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -20,0 dB 9 kHz do 10 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -20,0 dB 10 MHz do 45 MHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -20,0 dB 45 MHz do 500 MHz CMC 0,43°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -20,0 dB 500 MHz do 2 GHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -20,0 dB 2 GHz do 10 GHz CMC 0,53°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -20,0 dB 10 GHz do 20 GHz CMC 0,68°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -20,0 dB 20 GHz do 35 GHz CMC 0,88°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -20,0 dB 35 GHz do 44 GHz CMC 0,90°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = -20,0 dB 44 GHz do 50 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 0,0 dB 9 kHz do 10 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 0,0 dB 10 MHz do 45 MHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 0,0 dB 45 MHz do 500 MHz CMC 0,37°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 0,0 dB 500 MHz do 2 GHz CMC 0,35°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 0,0 dB 2 GHz do 10 GHz CMC 0,44°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 0,0 dB 10 GHz do 20 GHz CMC 0,59°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 0,0 dB 20 GHz do 35 GHz CMC 0,81°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 0,0 dB 35 GHz do 44 GHz CMC 0,82°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 0,0 dB 44 GHz do 50 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 20,0 dB 9 kHz do 10 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 20,0 dB 10 MHz do 45 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 20,0 dB 45 MHz do 500 MHz CMC 0,42°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 20,0 dB 500 MHz do 2 GHz CMC 0,59°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 20,0 dB 2 GHz do 10 GHz CMC 0,63°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 20,0 dB 10 GHz do 20 GHz CMC 0,77°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 20,0 dB 20 GHz do 35 GHz CMC 1,1°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 20,0 dB 35 GHz do 44 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 20,0 dB 44 GHz do 50 GHz CMC 1,6°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 40,0 dB 9 kHz do 10 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 40,0 dB 10 MHz do 45 MHz CMC 1,4°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 40,0 dB 45 MHz do 500 MHz CMC 0,50°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 40,0 dB 500 MHz do 2 GHz CMC 0,67°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 40,0 dB 2 GHz do 10 GHz CMC 0,70°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 40,0 dB 10 GHz do 20 GHz CMC 0,84°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 40,0 dB 20 GHz do 35 GHz CMC 1,2°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 40,0 dB 35 GHz do 44 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 40,0 dB 44 GHz do 50 GHz CMC 1,7°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 60,0 dB 9 kHz do 10 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 60,0 dB 10 MHz do 45 MHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 60,0 dB 45 MHz do 500 MHz CMC 0,57°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 60,0 dB 500 MHz do 2 GHz CMC 0,74°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 60,0 dB 2 GHz do 10 GHz CMC 0.77°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 60,0 dB 10 GHz do 20 GHz CMC 0,92°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 60,0 dB 20 GHz do 35 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 60,0 dB 35 GHz do 44 GHz CMC 1,3°\nMatryca CMC – transmisja S21 / S12 – faza (zlacze 2,4 mm); S21 / S12 = 60,0 dB 44 GHz do 50 GHz CMC 1,7°\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/34\nLMEEiO/48","search_en":"Fixed attenuators Variable attenuators Filters Directional couplers Switches Antenna and cable system analysers Amplifiers - transmission S21 / S12 Calibration — RF electrical quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) RF electrical quantities Internal procedure Direct method At permanent location (S) and outside of it (P) 9 kHz to 50 GHz CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 50 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (N 50 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (N 75 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (N 75 Ω connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (3,5 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – magnitude (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -80,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = -20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 0,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 20,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 40,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB CMC matrix – transmission S21 / S12 – phase (2,4 mm connector); S21 / S12 = 60,0 dB LMEEiO/34 LMEEiO/48","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":53,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — elektrische HF-Größen","parameters_de":[{"name":"9 kHz bis 50 GHz","range":"-80 dB to 60 dB","cmc":"CMC-Matrix auf den folgenden Seiten"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB","range":"9 kHz to 300 kHz","cmc":"1,4"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB","range":"300 kHz to 10 MHz","cmc":"0,74"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB","range":"10 MHz to 500 MHz","cmc":"0,53"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"0,38"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"0,45"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB","range":"10 GHz to 18 GHz","cmc":"0,51"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB","range":"9 kHz to 300 kHz","cmc":"0,28"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB","range":"300 kHz to 10 MHz","cmc":"0,22"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB","range":"10 MHz to 500 MHz","cmc":"0,20"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,090"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,16"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB","range":"10 GHz to 18 GHz","cmc":"0,22"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,050"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB","range":"10 GHz to 18 GHz","cmc":"0,18"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,079"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,079"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,078"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB","range":"10 GHz to 18 GHz","cmc":"0,17"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB","range":"9 kHz to 300 kHz","cmc":"0,047"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB","range":"300 kHz to 10 MHz","cmc":"0,047"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB","range":"10 MHz to 500 MHz","cmc":"0,047"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,024"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,092"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB","range":"10 GHz to 18 GHz","cmc":"0,16"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,071"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,071"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,071"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,034"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB","range":"10 GHz to 18 GHz","cmc":"0,16"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,069"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB","range":"10 GHz to 18 GHz","cmc":"0,20"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB","range":"9 kHz to 300 kHz","cmc":"0,20"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB","range":"300 kHz to 10 MHz","cmc":"0,20"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB","range":"10 MHz to 500 MHz","cmc":"0,20"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,079"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,15"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB","range":"10 GHz to 18 GHz","cmc":"0,21"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB","range":"9 kHz to 300 kHz","cmc":"9,6°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB","range":"300 kHz to 10 MHz","cmc":"5,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB","range":"10 MHz to 500 MHz","cmc":"3,7°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"2,6°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"3,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB","range":"10 GHz to 18 GHz","cmc":"3,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB","range":"9 kHz to 300 kHz","cmc":"1,9°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB","range":"300 kHz to 10 MHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB","range":"10 MHz to 500 MHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,60°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB","range":"10 GHz to 18 GHz","cmc":"1,5°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,86°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,81°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,80°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,34°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,80°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB","range":"10 GHz to 18 GHz","cmc":"1,2°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,55°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,55°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,55°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,24°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,71°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB","range":"10 GHz to 18 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB","range":"9 kHz to 300 kHz","cmc":"0,31°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB","range":"300 kHz to 10 MHz","cmc":"0,31°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB","range":"10 MHz to 500 MHz","cmc":"0,31°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,16°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,59°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB","range":"10 GHz to 18 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,47°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,47°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,47°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,23°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,67°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB","range":"10 GHz to 18 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,75°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,75°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,75°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,49°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,95°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB","range":"10 GHz to 18 GHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB","range":"9 kHz to 300 kHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB","range":"300 kHz to 10 MHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB","range":"10 MHz to 500 MHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,57°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB","range":"10 GHz to 18 GHz","cmc":"1,5°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -80,0 dB","range":"9 kHz to 30 kHz","cmc":"0,54"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -80,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,37"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -80,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,40"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -60,0 dB","range":"9 kHz to 30 kHz","cmc":"0,20"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,15"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,17"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,13"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,10"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,081"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,073"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,093"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 0,0 dB","range":"9 kHz to 30 kHz","cmc":"0,057"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 0,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,050"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 0,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,070"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,081"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,074"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,093"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,13"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 60,0 dB","range":"9 kHz to 30 kHz","cmc":"0,21"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,15"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,18"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -80,0 dB","range":"9 kHz to 30 kHz","cmc":"3,7°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -80,0 dB","range":"30 kHz to 1,3 GHz","cmc":"2,7°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -80,0 dB","range":"1,3 GHz to 3 GHz","cmc":"2,9°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -60,0 dB","range":"9 kHz to 30 kHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"1,2°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,83°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,68°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,81°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,54°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,49°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,62°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 0,0 dB","range":"9 kHz to 30 kHz","cmc":"0,38°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 0,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,33°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 0,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,47°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,54°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,50°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,63°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,80°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,69°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,84°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 60,0 dB","range":"9 kHz to 30 kHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"0,75"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"0,55"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"0,55"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"0,43"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"0,46"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,49"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,52"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,24"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,22"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,22"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,15"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,17"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,20"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,23"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,13"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,17"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,20"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,098"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,098"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,098"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,079"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,17"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,066"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,066"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,066"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,066"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,092"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,13"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,16"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,099"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,097"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,15"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,19"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,13"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,17"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,20"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,19"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,13"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,13"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,18"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,21"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"5,2°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"3,8°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"3,8°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"3,0°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"3,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"10 GHz bis 20 GHz","cmc":"3,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB","range":"20 GHz to 26,5 GHz","cmc":"3,5°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,6°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"11,5°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"1,5°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,96°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"1,2°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"10 GHz bis 20 GHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,6°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,94°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,93°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,93°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,71°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,86°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"10 GHz bis 20 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,68°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,68°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,68°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,53°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,71°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,94°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,2°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,44°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,44°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,44°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,44°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,61°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,84°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,68°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,67°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,69°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,69°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,80°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"10 GHz bis 20 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,93°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,74°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,76°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,76°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,87°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"10 GHz bis 20 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,82°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,83°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,83°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,95°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"10 GHz bis 20 GHz","cmc":"1,2°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,5°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"0,75"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"0,55"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"0,55"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"0,41"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"0,42"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,45"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"20 GHz to 35 GHz","cmc":"0,48"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"35 GHz to 44 GHz","cmc":"0,71"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"44 GHz to 50 GHz","cmc":"1,9"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,24"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,22"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,19"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,16"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"20 GHz to 35 GHz","cmc":"0,19"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"35 GHz to 44 GHz","cmc":"0,22"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"44 GHz to 50 GHz","cmc":"0,39"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,086"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,079"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,093"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"20 GHz to 35 GHz","cmc":"0,15"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"35 GHz to 44 GHz","cmc":"0,16"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"44 GHz to 50 GHz","cmc":"0,23"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,098"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,098"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,065"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,066"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,080"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"20 GHz to 35 GHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"35 GHz to 44 GHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"44 GHz to 50 GHz","cmc":"0,20"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,066"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,066"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,056"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,052"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,066"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,089"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"20 GHz to 35 GHz","cmc":"0,13"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"35 GHz to 44 GHz","cmc":"0,13"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"44 GHz to 50 GHz","cmc":"0,19"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,17"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,17"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,064"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,083"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,92"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"20 GHz to 35 GHz","cmc":"0,16"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"35 GHz to 44 GHz","cmc":"0,17"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"44 GHz to 50 GHz","cmc":"0,23"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,20"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,20"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,075"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,095"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,13"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"20 GHz to 35 GHz","cmc":"0,17"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"35 GHz to 44 GHz","cmc":"0,18"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"44 GHz to 50 GHz","cmc":"0,24"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,21"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,21"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,086"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,12"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,14"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"20 GHz to 35 GHz","cmc":"0,18"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"35 GHz to 44 GHz","cmc":"0,19"},{"name":"CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"44 GHz to 50 GHz","cmc":"0,25"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"5,2°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"3,8°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"3,8°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"2,8°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"2,9°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"10 GHz bis 20 GHz","cmc":"3,0°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"20 GHz to 35 GHz","cmc":"3,2°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"35 GHz to 44 GHz","cmc":"4,9°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB","range":"44 GHz to 50 GHz","cmc":"14°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,6°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"1,5°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,79°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,88°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"10 GHz bis 20 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"20 GHz to 35 GHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"35 GHz to 44 GHz","cmc":"1,5°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB","range":"44 GHz to 50 GHz","cmc":"2,7°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,94°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,93°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,57°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,53°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,62°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,77°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"20 GHz to 35 GHz","cmc":"0,97°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"35 GHz to 44 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB","range":"44 GHz to 50 GHz","cmc":"1,5°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,68°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,68°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,43°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,44°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,53°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,68°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"20 GHz to 35 GHz","cmc":"0,88°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"35 GHz to 44 GHz","cmc":"0,90°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB","range":"44 GHz to 50 GHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,44°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,44°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,37°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,35°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,44°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,59°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"20 GHz to 35 GHz","cmc":"0,81°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"35 GHz to 44 GHz","cmc":"0,82°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB","range":"44 GHz to 50 GHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,42°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,59°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,63°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,77°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"20 GHz to 35 GHz","cmc":"1,1°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"35 GHz to 44 GHz","cmc":"1,2°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB","range":"44 GHz to 50 GHz","cmc":"1,6°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"1,4°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,50°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,67°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,70°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,84°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"20 GHz to 35 GHz","cmc":"1,2°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"35 GHz to 44 GHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB","range":"44 GHz to 50 GHz","cmc":"1,7°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,57°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,74°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0.77°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"10 GHz bis 20 GHz","cmc":"0,92°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"20 GHz to 35 GHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"35 GHz to 44 GHz","cmc":"1,3°"},{"name":"CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB","range":"44 GHz to 50 GHz","cmc":"1,7°"}],"regulatory_area_de":"Elektrische HF-Größen","search_de":"Feste Dämpfungsglieder Einstellbare Dämpfungsglieder Filter Richtkoppler Schalter Analysatoren für Antennen- und Kabelsysteme Verstärker - Transmission S21 / S12 Kalibrierung — elektrische HF-Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische HF-Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 9 kHz bis 50 GHz CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 50 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder N 75 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder N 75 Ω); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 3,5 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Betrag (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -80,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = -20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 0,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 20,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 40,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB CMC-Matrix – Transmission S21 / S12 – Phase (Steckverbinder 2,4 mm); S21 / S12 = 60,0 dB LMEEiO/34 LMEEiO/48","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Feste Dämpfungsglieder\nEinstellbare Dämpfungsglieder\nFilter\nRichtkoppler\nSchalter\nAnalysatoren für Antennen- und Kabelsysteme\nVerstärker\n- Transmission S21 / S12","methodology_zh":"校准 — 射频电学量","parameters_zh":[{"name":"9 kHz 至 50 GHz","range":"-80 dB to 60 dB","cmc":"CMC 矩阵见后页"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -80,0 dB","range":"9 kHz to 300 kHz","cmc":"1,4"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -80,0 dB","range":"300 kHz to 10 MHz","cmc":"0,74"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -80,0 dB","range":"10 MHz to 500 MHz","cmc":"0,53"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"0,38"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"0,45"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -80,0 dB","range":"10 GHz to 18 GHz","cmc":"0,51"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -60,0 dB","range":"9 kHz to 300 kHz","cmc":"0,28"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -60,0 dB","range":"300 kHz to 10 MHz","cmc":"0,22"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -60,0 dB","range":"10 MHz to 500 MHz","cmc":"0,20"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,090"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,16"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -60,0 dB","range":"10 GHz to 18 GHz","cmc":"0,22"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,050"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -40,0 dB","range":"10 GHz to 18 GHz","cmc":"0,18"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,079"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,079"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,078"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -20,0 dB","range":"10 GHz to 18 GHz","cmc":"0,17"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 0,0 dB","range":"9 kHz to 300 kHz","cmc":"0,047"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 0,0 dB","range":"300 kHz to 10 MHz","cmc":"0,047"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 0,0 dB","range":"10 MHz to 500 MHz","cmc":"0,047"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,024"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,092"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 0,0 dB","range":"10 GHz to 18 GHz","cmc":"0,16"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,071"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,071"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,071"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,034"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 20,0 dB","range":"10 GHz to 18 GHz","cmc":"0,16"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,069"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 40,0 dB","range":"10 GHz to 18 GHz","cmc":"0,20"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 60,0 dB","range":"9 kHz to 300 kHz","cmc":"0,20"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 60,0 dB","range":"300 kHz to 10 MHz","cmc":"0,20"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 60,0 dB","range":"10 MHz to 500 MHz","cmc":"0,20"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,079"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,15"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 60,0 dB","range":"10 GHz to 18 GHz","cmc":"0,21"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -80,0 dB","range":"9 kHz to 300 kHz","cmc":"9,6°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -80,0 dB","range":"300 kHz to 10 MHz","cmc":"5,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -80,0 dB","range":"10 MHz to 500 MHz","cmc":"3,7°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"2,6°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"3,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -80,0 dB","range":"10 GHz to 18 GHz","cmc":"3,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -60,0 dB","range":"9 kHz to 300 kHz","cmc":"1,9°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -60,0 dB","range":"300 kHz to 10 MHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -60,0 dB","range":"10 MHz to 500 MHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,60°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -60,0 dB","range":"10 GHz to 18 GHz","cmc":"1,5°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,86°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,81°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,80°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,34°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,80°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -40,0 dB","range":"10 GHz to 18 GHz","cmc":"1,2°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,55°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,55°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,55°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,24°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,71°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -20,0 dB","range":"10 GHz to 18 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 0,0 dB","range":"9 kHz to 300 kHz","cmc":"0,31°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 0,0 dB","range":"300 kHz to 10 MHz","cmc":"0,31°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 0,0 dB","range":"10 MHz to 500 MHz","cmc":"0,31°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,16°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,59°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 0,0 dB","range":"10 GHz to 18 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,47°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,47°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,47°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,23°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,67°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 20,0 dB","range":"10 GHz to 18 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,75°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,75°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,75°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,49°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,95°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 40,0 dB","range":"10 GHz to 18 GHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 60,0 dB","range":"9 kHz to 300 kHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 60,0 dB","range":"300 kHz to 10 MHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 60,0 dB","range":"10 MHz to 500 MHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,57°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 60,0 dB","range":"10 GHz to 18 GHz","cmc":"1,5°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -80,0 dB","range":"9 kHz to 30 kHz","cmc":"0,54"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -80,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,37"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -80,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,40"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -60,0 dB","range":"9 kHz to 30 kHz","cmc":"0,20"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,15"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,17"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,13"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,10"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,081"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,073"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,093"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 0,0 dB","range":"9 kHz to 30 kHz","cmc":"0,057"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 0,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,050"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 0,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,070"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,081"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,074"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,093"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,13"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 60,0 dB","range":"9 kHz to 30 kHz","cmc":"0,21"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,15"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,18"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -80,0 dB","range":"9 kHz to 30 kHz","cmc":"3,7°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -80,0 dB","range":"30 kHz to 1,3 GHz","cmc":"2,7°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -80,0 dB","range":"1,3 GHz to 3 GHz","cmc":"2,9°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -60,0 dB","range":"9 kHz to 30 kHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"1,2°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,83°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,68°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,81°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,54°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,49°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,62°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 0,0 dB","range":"9 kHz to 30 kHz","cmc":"0,38°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 0,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,33°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 0,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,47°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,54°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,50°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,63°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,80°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,69°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,84°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 60,0 dB","range":"9 kHz to 30 kHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"0,75"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"0,55"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"0,55"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"0,43"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"0,46"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,49"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,52"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,24"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,22"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,22"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,15"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,17"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,20"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,23"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,13"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,17"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,20"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,098"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,098"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,098"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,079"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,17"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,066"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,066"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,066"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,066"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,092"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,13"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,16"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,099"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,097"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,15"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,19"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,13"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,17"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,20"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,19"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,13"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,13"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,18"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,21"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"5,2°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"3,8°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"3,8°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"3,0°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"3,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"10 GHz 至 20 GHz","cmc":"3,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB","range":"20 GHz to 26,5 GHz","cmc":"3,5°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,6°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"11,5°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"1,5°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,96°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"1,2°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"10 GHz 至 20 GHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,6°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,94°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,93°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,93°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,71°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,86°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"10 GHz 至 20 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,68°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,68°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,68°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,53°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,71°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,94°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,2°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,44°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,44°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,44°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,44°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,61°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,84°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,68°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,67°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,69°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,69°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,80°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"10 GHz 至 20 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,93°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,74°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,76°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,76°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,87°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"10 GHz 至 20 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,82°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,83°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,83°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,95°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"10 GHz 至 20 GHz","cmc":"1,2°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,5°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"0,75"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"0,55"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"0,55"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"0,41"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"0,42"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,45"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"20 GHz to 35 GHz","cmc":"0,48"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"35 GHz to 44 GHz","cmc":"0,71"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"44 GHz to 50 GHz","cmc":"1,9"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,24"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,22"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,19"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,16"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"20 GHz to 35 GHz","cmc":"0,19"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"35 GHz to 44 GHz","cmc":"0,22"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"44 GHz to 50 GHz","cmc":"0,39"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,086"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,079"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,093"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"20 GHz to 35 GHz","cmc":"0,15"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"35 GHz to 44 GHz","cmc":"0,16"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"44 GHz to 50 GHz","cmc":"0,23"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,098"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,098"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,065"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,066"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,080"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"20 GHz to 35 GHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"35 GHz to 44 GHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"44 GHz to 50 GHz","cmc":"0,20"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,066"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,066"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,056"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,052"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,066"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,089"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"20 GHz to 35 GHz","cmc":"0,13"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"35 GHz to 44 GHz","cmc":"0,13"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"44 GHz to 50 GHz","cmc":"0,19"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,17"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,17"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,064"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,083"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,92"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"20 GHz to 35 GHz","cmc":"0,16"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"35 GHz to 44 GHz","cmc":"0,17"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"44 GHz to 50 GHz","cmc":"0,23"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,20"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,20"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,075"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,095"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,13"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"20 GHz to 35 GHz","cmc":"0,17"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"35 GHz to 44 GHz","cmc":"0,18"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"44 GHz to 50 GHz","cmc":"0,24"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,21"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,21"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,086"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,12"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,14"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"20 GHz to 35 GHz","cmc":"0,18"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"35 GHz to 44 GHz","cmc":"0,19"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"44 GHz to 50 GHz","cmc":"0,25"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"5,2°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"3,8°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"3,8°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"2,8°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"2,9°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"10 GHz 至 20 GHz","cmc":"3,0°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"20 GHz to 35 GHz","cmc":"3,2°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"35 GHz to 44 GHz","cmc":"4,9°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB","range":"44 GHz to 50 GHz","cmc":"14°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,6°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"1,5°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,79°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,88°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"10 GHz 至 20 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"20 GHz to 35 GHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"35 GHz to 44 GHz","cmc":"1,5°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB","range":"44 GHz to 50 GHz","cmc":"2,7°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,94°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,93°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,57°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,53°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,62°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,77°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"20 GHz to 35 GHz","cmc":"0,97°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"35 GHz to 44 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB","range":"44 GHz to 50 GHz","cmc":"1,5°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,68°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,68°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,43°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,44°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,53°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,68°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"20 GHz to 35 GHz","cmc":"0,88°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"35 GHz to 44 GHz","cmc":"0,90°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB","range":"44 GHz to 50 GHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,44°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,44°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,37°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,35°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,44°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,59°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"20 GHz to 35 GHz","cmc":"0,81°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"35 GHz to 44 GHz","cmc":"0,82°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB","range":"44 GHz to 50 GHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,42°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,59°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,63°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,77°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"20 GHz to 35 GHz","cmc":"1,1°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"35 GHz to 44 GHz","cmc":"1,2°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB","range":"44 GHz to 50 GHz","cmc":"1,6°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"1,4°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,50°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,67°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,70°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,84°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"20 GHz to 35 GHz","cmc":"1,2°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"35 GHz to 44 GHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB","range":"44 GHz to 50 GHz","cmc":"1,7°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,57°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,74°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0.77°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"10 GHz 至 20 GHz","cmc":"0,92°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"20 GHz to 35 GHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"35 GHz to 44 GHz","cmc":"1,3°"},{"name":"CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB","range":"44 GHz to 50 GHz","cmc":"1,7°"}],"regulatory_area_zh":"射频电学量","search_zh":"固定衰减器 可调衰减器 过滤器 定向耦合器 开关 天线与电缆系统分析仪 放大器 - 传输 S21 / S12 校准 — 射频电学量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 射频电学量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 9 kHz 至 50 GHz CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 50 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 50 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (N 75 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (N 75 Ω 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (3,5 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 幅值 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -80,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = -20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 0,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 20,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 40,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB CMC 矩阵 – 传输 S21 / S12 – 相位 (2,4 mm 连接器); S21 / S12 = 60,0 dB LMEEiO/34 LMEEiO/48","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"固定衰减器\n可调衰减器\n过滤器\n定向耦合器\n开关\n天线与电缆系统分析仪\n放大器\n- 传输 S21 / S12","methodology_cs":"Kalibrace — Vysokofrekvenční elektrické veličiny","parameters_cs":[{"name":"9 kHz až 50 GHz","range":"-80 dB to 60 dB","cmc":"Matice CMC na dalších stranách"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -80,0 dB","range":"9 kHz to 300 kHz","cmc":"1,4"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -80,0 dB","range":"300 kHz to 10 MHz","cmc":"0,74"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -80,0 dB","range":"10 MHz to 500 MHz","cmc":"0,53"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"0,38"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"0,45"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -80,0 dB","range":"10 GHz to 18 GHz","cmc":"0,51"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -60,0 dB","range":"9 kHz to 300 kHz","cmc":"0,28"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -60,0 dB","range":"300 kHz to 10 MHz","cmc":"0,22"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -60,0 dB","range":"10 MHz to 500 MHz","cmc":"0,20"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,090"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,16"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -60,0 dB","range":"10 GHz to 18 GHz","cmc":"0,22"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,050"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -40,0 dB","range":"10 GHz to 18 GHz","cmc":"0,18"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,079"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,079"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,078"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -20,0 dB","range":"10 GHz to 18 GHz","cmc":"0,17"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 0,0 dB","range":"9 kHz to 300 kHz","cmc":"0,047"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 0,0 dB","range":"300 kHz to 10 MHz","cmc":"0,047"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 0,0 dB","range":"10 MHz to 500 MHz","cmc":"0,047"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,024"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,092"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 0,0 dB","range":"10 GHz to 18 GHz","cmc":"0,16"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,071"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,071"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,071"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,034"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 20,0 dB","range":"10 GHz to 18 GHz","cmc":"0,16"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,069"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 40,0 dB","range":"10 GHz to 18 GHz","cmc":"0,20"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 60,0 dB","range":"9 kHz to 300 kHz","cmc":"0,20"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 60,0 dB","range":"300 kHz to 10 MHz","cmc":"0,20"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 60,0 dB","range":"10 MHz to 500 MHz","cmc":"0,20"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,079"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,15"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 60,0 dB","range":"10 GHz to 18 GHz","cmc":"0,21"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -80,0 dB","range":"9 kHz to 300 kHz","cmc":"9,6°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -80,0 dB","range":"300 kHz to 10 MHz","cmc":"5,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -80,0 dB","range":"10 MHz to 500 MHz","cmc":"3,7°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"2,6°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"3,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -80,0 dB","range":"10 GHz to 18 GHz","cmc":"3,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -60,0 dB","range":"9 kHz to 300 kHz","cmc":"1,9°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -60,0 dB","range":"300 kHz to 10 MHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -60,0 dB","range":"10 MHz to 500 MHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,60°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -60,0 dB","range":"10 GHz to 18 GHz","cmc":"1,5°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,86°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,81°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,80°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,34°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,80°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -40,0 dB","range":"10 GHz to 18 GHz","cmc":"1,2°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,55°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,55°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,55°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,24°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,71°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -20,0 dB","range":"10 GHz to 18 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 0,0 dB","range":"9 kHz to 300 kHz","cmc":"0,31°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 0,0 dB","range":"300 kHz to 10 MHz","cmc":"0,31°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 0,0 dB","range":"10 MHz to 500 MHz","cmc":"0,31°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,16°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,59°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 0,0 dB","range":"10 GHz to 18 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 20,0 dB","range":"9 kHz to 300 kHz","cmc":"0,47°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 20,0 dB","range":"300 kHz to 10 MHz","cmc":"0,47°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 20,0 dB","range":"10 MHz to 500 MHz","cmc":"0,47°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,23°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,67°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 20,0 dB","range":"10 GHz to 18 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 40,0 dB","range":"9 kHz to 300 kHz","cmc":"0,75°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 40,0 dB","range":"300 kHz to 10 MHz","cmc":"0,75°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 40,0 dB","range":"10 MHz to 500 MHz","cmc":"0,75°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,49°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,95°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 40,0 dB","range":"10 GHz to 18 GHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 60,0 dB","range":"9 kHz to 300 kHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 60,0 dB","range":"300 kHz to 10 MHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 60,0 dB","range":"10 MHz to 500 MHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,57°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 60,0 dB","range":"10 GHz to 18 GHz","cmc":"1,5°"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -80,0 dB","range":"9 kHz to 30 kHz","cmc":"0,54"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -80,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,37"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -80,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,40"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -60,0 dB","range":"9 kHz to 30 kHz","cmc":"0,20"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,15"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,17"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,13"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,10"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,081"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,073"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,093"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 0,0 dB","range":"9 kHz to 30 kHz","cmc":"0,057"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 0,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,050"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 0,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,070"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,081"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,074"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,093"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,13"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 60,0 dB","range":"9 kHz to 30 kHz","cmc":"0,21"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,15"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,18"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -80,0 dB","range":"9 kHz to 30 kHz","cmc":"3,7°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -80,0 dB","range":"30 kHz to 1,3 GHz","cmc":"2,7°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -80,0 dB","range":"1,3 GHz to 3 GHz","cmc":"2,9°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -60,0 dB","range":"9 kHz to 30 kHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"1,2°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,83°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,68°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,81°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,54°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,49°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,62°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 0,0 dB","range":"9 kHz to 30 kHz","cmc":"0,38°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 0,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,33°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 0,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,47°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 20,0 dB","range":"9 kHz to 30 kHz","cmc":"0,54°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 20,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,50°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 20,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,63°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 40,0 dB","range":"9 kHz to 30 kHz","cmc":"0,80°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 40,0 dB","range":"30 kHz to 1,3 GHz","cmc":"0,69°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 40,0 dB","range":"1,3 GHz to 3 GHz","cmc":"0,84°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 60,0 dB","range":"9 kHz to 30 kHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 60,0 dB","range":"30 kHz to 1,3 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 60,0 dB","range":"1,3 GHz to 3 GHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"0,75"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"0,55"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"0,55"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"0,43"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"0,46"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"10 GHz až 20 GHz","cmc":"0,49"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,52"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,24"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,22"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,22"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,15"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,17"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"10 GHz až 20 GHz","cmc":"0,20"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,23"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,13"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"10 GHz až 20 GHz","cmc":"0,17"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,20"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,098"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,098"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,098"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,079"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"10 GHz až 20 GHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,17"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,066"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,066"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,066"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,066"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,092"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"10 GHz až 20 GHz","cmc":"0,13"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,16"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,099"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,097"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"10 GHz až 20 GHz","cmc":"0,15"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,19"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,13"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"10 GHz až 20 GHz","cmc":"0,17"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,20"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,19"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,13"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,13"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"10 GHz až 20 GHz","cmc":"0,18"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"0,21"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"5,2°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"3,8°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"3,8°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"3,0°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"3,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"10 GHz až 20 GHz","cmc":"3,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB","range":"20 GHz to 26,5 GHz","cmc":"3,5°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,6°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"11,5°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"1,5°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,96°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"1,2°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"10 GHz až 20 GHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,6°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,94°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,93°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,93°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,71°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,86°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"10 GHz až 20 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,68°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,68°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,68°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,53°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,71°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"10 GHz až 20 GHz","cmc":"0,94°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,2°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,44°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,44°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,44°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,44°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,61°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"10 GHz až 20 GHz","cmc":"0,84°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,68°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,67°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,69°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,69°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,80°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"10 GHz až 20 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,93°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,74°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,76°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,76°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,87°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"10 GHz až 20 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,82°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,83°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,83°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,95°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"10 GHz až 20 GHz","cmc":"1,2°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB","range":"20 GHz to 26,5 GHz","cmc":"1,5°"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"0,75"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"0,55"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"0,55"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"0,41"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"0,42"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"10 GHz až 20 GHz","cmc":"0,45"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"20 GHz to 35 GHz","cmc":"0,48"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"35 GHz to 44 GHz","cmc":"0,71"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"44 GHz to 50 GHz","cmc":"1,9"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,24"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,22"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,19"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"10 GHz až 20 GHz","cmc":"0,16"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"20 GHz to 35 GHz","cmc":"0,19"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"35 GHz to 44 GHz","cmc":"0,22"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"44 GHz to 50 GHz","cmc":"0,39"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,086"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,079"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,093"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"10 GHz až 20 GHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"20 GHz to 35 GHz","cmc":"0,15"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"35 GHz to 44 GHz","cmc":"0,16"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"44 GHz to 50 GHz","cmc":"0,23"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,098"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,098"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,065"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,066"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,080"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"10 GHz až 20 GHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"20 GHz to 35 GHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"35 GHz to 44 GHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"44 GHz to 50 GHz","cmc":"0,20"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,066"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,066"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,056"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,052"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,066"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"10 GHz až 20 GHz","cmc":"0,089"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"20 GHz to 35 GHz","cmc":"0,13"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"35 GHz to 44 GHz","cmc":"0,13"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"44 GHz to 50 GHz","cmc":"0,19"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,17"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,17"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,064"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,083"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,92"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"10 GHz až 20 GHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"20 GHz to 35 GHz","cmc":"0,16"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"35 GHz to 44 GHz","cmc":"0,17"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"44 GHz to 50 GHz","cmc":"0,23"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,20"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,20"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,075"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,095"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"10 GHz až 20 GHz","cmc":"0,13"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"20 GHz to 35 GHz","cmc":"0,17"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"35 GHz to 44 GHz","cmc":"0,18"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"44 GHz to 50 GHz","cmc":"0,24"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"0,21"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"0,21"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,086"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,11"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,12"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"10 GHz až 20 GHz","cmc":"0,14"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"20 GHz to 35 GHz","cmc":"0,18"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"35 GHz to 44 GHz","cmc":"0,19"},{"name":"Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"44 GHz to 50 GHz","cmc":"0,25"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"9 kHz to 10 MHz","cmc":"5,2°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"10 MHz to 45 MHz","cmc":"3,8°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"45 MHz to 500 MHz","cmc":"3,8°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"500 MHz to 2 GHz","cmc":"2,8°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"2 GHz to 10 GHz","cmc":"2,9°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"10 GHz až 20 GHz","cmc":"3,0°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"20 GHz to 35 GHz","cmc":"3,2°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"35 GHz to 44 GHz","cmc":"4,9°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB","range":"44 GHz to 50 GHz","cmc":"14°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,6°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"10 MHz to 45 MHz","cmc":"1,5°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"45 MHz to 500 MHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,79°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"2 GHz to 10 GHz","cmc":"0,88°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"10 GHz až 20 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"20 GHz to 35 GHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"35 GHz to 44 GHz","cmc":"1,5°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB","range":"44 GHz to 50 GHz","cmc":"2,7°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"9 kHz to 10 MHz","cmc":"0,94°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"10 MHz to 45 MHz","cmc":"0,93°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,57°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,53°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,62°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"10 GHz až 20 GHz","cmc":"0,77°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"20 GHz to 35 GHz","cmc":"0,97°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"35 GHz to 44 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB","range":"44 GHz to 50 GHz","cmc":"1,5°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"9 kHz to 10 MHz","cmc":"0,68°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"10 MHz to 45 MHz","cmc":"0,68°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,43°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,44°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,53°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"10 GHz až 20 GHz","cmc":"0,68°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"20 GHz to 35 GHz","cmc":"0,88°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"35 GHz to 44 GHz","cmc":"0,90°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB","range":"44 GHz to 50 GHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"9 kHz to 10 MHz","cmc":"0,44°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"10 MHz to 45 MHz","cmc":"0,44°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"45 MHz to 500 MHz","cmc":"0,37°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"500 MHz to 2 GHz","cmc":"0,35°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"2 GHz to 10 GHz","cmc":"0,44°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"10 GHz až 20 GHz","cmc":"0,59°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"20 GHz to 35 GHz","cmc":"0,81°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"35 GHz to 44 GHz","cmc":"0,82°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB","range":"44 GHz to 50 GHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"9 kHz to 10 MHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"10 MHz to 45 MHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"45 MHz to 500 MHz","cmc":"0,42°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"500 MHz to 2 GHz","cmc":"0,59°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"2 GHz to 10 GHz","cmc":"0,63°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"10 GHz až 20 GHz","cmc":"0,77°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"20 GHz to 35 GHz","cmc":"1,1°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"35 GHz to 44 GHz","cmc":"1,2°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB","range":"44 GHz to 50 GHz","cmc":"1,6°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"9 kHz to 10 MHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"10 MHz to 45 MHz","cmc":"1,4°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"45 MHz to 500 MHz","cmc":"0,50°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"500 MHz to 2 GHz","cmc":"0,67°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"2 GHz to 10 GHz","cmc":"0,70°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"10 GHz až 20 GHz","cmc":"0,84°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"20 GHz to 35 GHz","cmc":"1,2°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"35 GHz to 44 GHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB","range":"44 GHz to 50 GHz","cmc":"1,7°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"9 kHz to 10 MHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"10 MHz to 45 MHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"45 MHz to 500 MHz","cmc":"0,57°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"500 MHz to 2 GHz","cmc":"0,74°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"2 GHz to 10 GHz","cmc":"0.77°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"10 GHz až 20 GHz","cmc":"0,92°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"20 GHz to 35 GHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"35 GHz to 44 GHz","cmc":"1,3°"},{"name":"Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB","range":"44 GHz to 50 GHz","cmc":"1,7°"}],"regulatory_area_cs":"Vysokofrekvenční elektrické veličiny","search_cs":"Pevné útlumové články Nastavitelné útlumové články Filtry Směrové vazební členy Spínače Analyzátory anténních a kabelových systémů Zesilovače - přenos S21 / S12 Kalibrace — Vysokofrekvenční elektrické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Vysokofrekvenční elektrické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 9 kHz až 50 GHz Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 50 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 50 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor N 75 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor N 75 Ω); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 3,5 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – modul (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -80,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = -20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 0,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 20,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 40,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB Matice CMC – přenos S21 / S12 – fáze (konektor 2,4 mm); S21 / S12 = 60,0 dB LMEEiO/34 LMEEiO/48","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Pevné útlumové články\nNastavitelné útlumové články\nFiltry\nSměrové vazební členy\nSpínače\nAnalyzátory anténních a kabelových systémů\nZesilovače\n- přenos S21 / S12"},{"_id":"4465bdfd7fe1debaf630c5a4","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory przedziałów czasu","test_object_en":"Time interval generators","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"100 ps do 200 s","cmc":"20 ps + 1 · 10⁻¹¹ · t"},{"name":"","range":"200 s do 10⁵ s","cmc":"1 ns + 7 · 10⁻¹⁴ · t"},{"name":"liczba uśrednianych okresów nie mniejsza niż 10","range":"pomiary okresu średniego","cmc":"1 · 10⁻¹¹ · t"}],"parameters_en":[{"name":"","range":"100 ps to 200 s","cmc":"20 ps + 1 · 10⁻¹¹ · t"},{"name":"","range":"200 s to 10⁵ s","cmc":"1 ns + 7 · 10⁻¹⁴ · t"},{"name":"number of averaged periods not less than 10","range":"average period measurements","cmc":"1 · 10⁻¹¹ · t"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\n100 ps do 200 s CMC 20 ps + 1 · 10⁻¹¹ · t\n200 s do 10⁵ s CMC 1 ns + 7 · 10⁻¹⁴ · t\nliczba uśrednianych okresów nie mniejsza niż 10 pomiary okresu średniego CMC 1 · 10⁻¹¹ · t\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LMEEiO/7\nLMEEiO/9","norm_bases":["LMEEiO/7","LMEEiO/9"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":"t – wielkość mierzona (s)","note_en":"t – measured value (s)","search_text":"Generatory przedziałów czasu Wzorcowanie — Czas (przedział czasu)\nZakres:\n100 ps do 200 s CMC 20 ps + 1 · 10⁻¹¹ · t\n200 s do 10⁵ s CMC 1 ns + 7 · 10⁻¹⁴ · t\nliczba uśrednianych okresów nie mniejsza niż 10 pomiary okresu średniego CMC 1 · 10⁻¹¹ · t\nProcedura wewnętrzna; W stałej lokalizacji (S) LMEEiO/7\nLMEEiO/9 Generatory przedzialow czasu Wzorcowanie — Czas (przedzial czasu)\nZakres:\n100 ps do 200 s CMC 20 ps + 1 · 10⁻¹¹ · t\n200 s do 10⁵ s CMC 1 ns + 7 · 10⁻¹⁴ · t\nliczba usrednianych okresow nie mniejsza niz 10 pomiary okresu sredniego CMC 1 · 10⁻¹¹ · t\nProcedura wewnetrzna; W stalej lokalizacji (S) LMEEiO/7\nLMEEiO/9","search_en":"Time interval generators Calibration — Time (time interval) Internal procedure; At permanent location (S) Time (time interval) Internal procedure At permanent location (S) number of averaged periods not less than 10 LMEEiO/7 LMEEiO/9","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":54,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"100 ps to 200 s","cmc":"20 ps + 1 · 10⁻¹¹ · t"},{"name":"","range":"200 s to 10⁵ s","cmc":"1 ns + 7 · 10⁻¹⁴ · t"},{"name":"Anzahl der gemittelten Perioden nicht kleiner als 10","range":"average period measurements","cmc":"1 · 10⁻¹¹ · t"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Zeitintervallgeneratoren Kalibrierung — Zeit (Zeitintervall) Internes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Am festen Standort (S) Anzahl der gemittelten Perioden nicht kleiner als 10 LMEEiO/7 LMEEiO/9","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Zeitintervallgeneratoren","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"100 ps to 200 s","cmc":"20 ps + 1 · 10⁻¹¹ · t"},{"name":"","range":"200 s to 10⁵ s","cmc":"1 ns + 7 · 10⁻¹⁴ · t"},{"name":"平均周期数不少于 10","range":"average period measurements","cmc":"1 · 10⁻¹¹ · t"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"时间间隔发生器 校准 — 时间（时间间隔） 内部程序；在固定地点 (S) 时间（时间间隔） 内部程序 在固定地点 (S) 平均周期数不少于 10 LMEEiO/7 LMEEiO/9","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"时间间隔发生器","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"100 ps to 200 s","cmc":"20 ps + 1 · 10⁻¹¹ · t"},{"name":"","range":"200 s to 10⁵ s","cmc":"1 ns + 7 · 10⁻¹⁴ · t"},{"name":"počet průměrovaných period nejméně 10","range":"average period measurements","cmc":"1 · 10⁻¹¹ · t"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Generátory časových intervalů Kalibrace — Čas (časový interval) Vnitřní postup; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Ve stálé lokalitě (S) počet průměrovaných period nejméně 10 LMEEiO/7 LMEEiO/9","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Generátory časových intervalů"},{"_id":"d2551ab7677e6387cdac8dae","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory przedziałów czasu","test_object_en":"Time interval generators","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"100 ps do 10⁵ s","cmc":"20 ps + 1 · 10⁻¹⁰ · t"},{"name":"liczba uśrednianych okresów nie mniejsza niż 10","range":"pomiary okresu średniego","cmc":"1 · 10⁻¹⁰ · t"}],"parameters_en":[{"name":"","range":"100 ps to 10⁵ s","cmc":"20 ps + 1 · 10⁻¹⁰ · t"},{"name":"number of averaged periods not less than 10","range":"average period measurements","cmc":"1 · 10⁻¹⁰ · t"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\n100 ps do 10⁵ s CMC 20 ps + 1 · 10⁻¹⁰ · t\nliczba uśrednianych okresów nie mniejsza niż 10 pomiary okresu średniego CMC 1 · 10⁻¹⁰ · t\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"LMEEiO/7\nLMEEiO/9","norm_bases":["LMEEiO/7","LMEEiO/9"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":true,"location_of_activity":"P","note":"t – wielkość mierzona (s)","note_en":"t – measured value (s)","search_text":"Generatory przedziałów czasu Wzorcowanie — Czas (przedział czasu)\nZakres:\n100 ps do 10⁵ s CMC 20 ps + 1 · 10⁻¹⁰ · t\nliczba uśrednianych okresów nie mniejsza niż 10 pomiary okresu średniego CMC 1 · 10⁻¹⁰ · t\nProcedura wewnętrzna; Poza stałą lokalizacją (P) LMEEiO/7\nLMEEiO/9 Generatory przedzialow czasu Wzorcowanie — Czas (przedzial czasu)\nZakres:\n100 ps do 10⁵ s CMC 20 ps + 1 · 10⁻¹⁰ · t\nliczba usrednianych okresow nie mniejsza niz 10 pomiary okresu sredniego CMC 1 · 10⁻¹⁰ · t\nProcedura wewnetrzna; Poza stala lokalizacja (P) LMEEiO/7\nLMEEiO/9","search_en":"Time interval generators Calibration — Time (time interval) Internal procedure; Outside of permanent location (P) Time (time interval) Internal procedure Outside of permanent location (P) number of averaged periods not less than 10 LMEEiO/7 LMEEiO/9","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":55,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"100 ps to 10⁵ s","cmc":"20 ps + 1 · 10⁻¹⁰ · t"},{"name":"Anzahl der gemittelten Perioden nicht kleiner als 10","range":"average period measurements","cmc":"1 · 10⁻¹⁰ · t"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Zeitintervallgeneratoren Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Zeit (Zeitintervall) Internes Verfahren Außerhalb des festen Standorts (P) Anzahl der gemittelten Perioden nicht kleiner als 10 LMEEiO/7 LMEEiO/9","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Zeitintervallgeneratoren","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"100 ps to 10⁵ s","cmc":"20 ps + 1 · 10⁻¹⁰ · t"},{"name":"平均周期数不少于 10","range":"average period measurements","cmc":"1 · 10⁻¹⁰ · t"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"时间间隔发生器 校准 — 时间（时间间隔） 内部程序；固定地点以外 (P) 时间（时间间隔） 内部程序 固定地点以外 (P) 平均周期数不少于 10 LMEEiO/7 LMEEiO/9","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"时间间隔发生器","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"100 ps to 10⁵ s","cmc":"20 ps + 1 · 10⁻¹⁰ · t"},{"name":"počet průměrovaných period nejméně 10","range":"average period measurements","cmc":"1 · 10⁻¹⁰ · t"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Generátory časových intervalů Kalibrace — Čas (časový interval) Vnitřní postup; Mimo stálé pracoviště (P) Čas (časový interval) Vnitřní postup Mimo stálou lokalitu (P) počet průměrovaných period nejméně 10 LMEEiO/7 LMEEiO/9","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Generátory časových intervalů"},{"_id":"4b3d5db9734d34682fdd9bab","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Reflektometry światłowodowe jedno i wielomodowe","test_object_en":"Single-mode and multimode optical time-domain reflectometers","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"400 ps do 100 ns","cmc":"4,6 · 10⁻⁴ ns"},{"name":"","range":"100 ns do 1 µs","cmc":"4,9 · 10⁻⁴ ns"},{"name":"","range":"1 µs do 10 µs","cmc":"7,0 · 10⁻⁴ ns"},{"name":"","range":"10 µs do 100 µs","cmc":"2,8 · 10⁻³ ns"},{"name":"","range":"100 µs do 1 ms","cmc":"2,4 · 10⁻² ns"},{"name":"","range":"1 ms do 10 ms","cmc":"2,3 · 10⁻¹ ns"},{"name":"","range":"10 ms do 100 ms","cmc":"2,3 ns"},{"name":"","range":"100 ms do 1 s","cmc":"23 ns"}],"parameters_en":[{"name":"","range":"400 ps to 100 ns","cmc":"4,6 · 10⁻⁴ ns"},{"name":"","range":"100 ns to 1 µs","cmc":"4,9 · 10⁻⁴ ns"},{"name":"","range":"1 µs to 10 µs","cmc":"7,0 · 10⁻⁴ ns"},{"name":"","range":"10 µs to 100 µs","cmc":"2,8 · 10⁻³ ns"},{"name":"","range":"100 µs to 1 ms","cmc":"2,4 · 10⁻² ns"},{"name":"","range":"1 ms to 10 ms","cmc":"2,3 · 10⁻¹ ns"},{"name":"","range":"10 ms to 100 ms","cmc":"2,3 ns"},{"name":"","range":"100 ms to 1 s","cmc":"23 ns"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\n400 ps do 100 ns CMC 4,6 · 10⁻⁴ ns\n100 ns do 1 µs CMC 4,9 · 10⁻⁴ ns\n1 µs do 10 µs CMC 7,0 · 10⁻⁴ ns\n10 µs do 100 µs CMC 2,8 · 10⁻³ ns\n100 µs do 1 ms CMC 2,4 · 10⁻² ns\n1 ms do 10 ms CMC 2,3 · 10⁻¹ ns\n10 ms do 100 ms CMC 2,3 ns\n100 ms do 1 s CMC 23 ns\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21","norm_bases":["LMEEiO/21"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Reflektometry światłowodowe jedno i wielomodowe Wzorcowanie — Czas (przedział czasu)\nZakres:\n400 ps do 100 ns CMC 4,6 · 10⁻⁴ ns\n100 ns do 1 µs CMC 4,9 · 10⁻⁴ ns\n1 µs do 10 µs CMC 7,0 · 10⁻⁴ ns\n10 µs do 100 µs CMC 2,8 · 10⁻³ ns\n100 µs do 1 ms CMC 2,4 · 10⁻² ns\n1 ms do 10 ms CMC 2,3 · 10⁻¹ ns\n10 ms do 100 ms CMC 2,3 ns\n100 ms do 1 s CMC 23 ns\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21 Reflektometry swiatlowodowe jedno i wielomodowe Wzorcowanie — Czas (przedzial czasu)\nZakres:\n400 ps do 100 ns CMC 4,6 · 10⁻⁴ ns\n100 ns do 1 µs CMC 4,9 · 10⁻⁴ ns\n1 µs do 10 µs CMC 7,0 · 10⁻⁴ ns\n10 µs do 100 µs CMC 2,8 · 10⁻³ ns\n100 µs do 1 ms CMC 2,4 · 10⁻² ns\n1 ms do 10 ms CMC 2,3 · 10⁻¹ ns\n10 ms do 100 ms CMC 2,3 ns\n100 ms do 1 s CMC 23 ns\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21","search_en":"Single-mode and multimode optical time-domain reflectometers Calibration — Time (time interval) Internal procedure; At permanent location (S) and outside of it (P) Time (time interval) Internal procedure At permanent location (S) and outside of it (P) LMEEiO/21","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":56,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"400 ps to 100 ns","cmc":"4,6 · 10⁻⁴ ns"},{"name":"","range":"100 ns to 1 µs","cmc":"4,9 · 10⁻⁴ ns"},{"name":"","range":"1 µs to 10 µs","cmc":"7,0 · 10⁻⁴ ns"},{"name":"","range":"10 µs to 100 µs","cmc":"2,8 · 10⁻³ ns"},{"name":"","range":"100 µs to 1 ms","cmc":"2,4 · 10⁻² ns"},{"name":"","range":"1 ms to 10 ms","cmc":"2,3 · 10⁻¹ ns"},{"name":"","range":"10 ms to 100 ms","cmc":"2,3 ns"},{"name":"","range":"100 ms to 1 s","cmc":"23 ns"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Singlemode- und Multimode-Lichtwellenleiter-Reflektometer Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Zeit (Zeitintervall) Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/21","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Singlemode- und Multimode-Lichtwellenleiter-Reflektometer","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"400 ps to 100 ns","cmc":"4,6 · 10⁻⁴ ns"},{"name":"","range":"100 ns to 1 µs","cmc":"4,9 · 10⁻⁴ ns"},{"name":"","range":"1 µs to 10 µs","cmc":"7,0 · 10⁻⁴ ns"},{"name":"","range":"10 µs to 100 µs","cmc":"2,8 · 10⁻³ ns"},{"name":"","range":"100 µs to 1 ms","cmc":"2,4 · 10⁻² ns"},{"name":"","range":"1 ms to 10 ms","cmc":"2,3 · 10⁻¹ ns"},{"name":"","range":"10 ms to 100 ms","cmc":"2,3 ns"},{"name":"","range":"100 ms to 1 s","cmc":"23 ns"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"单模和多模光时域反射仪 校准 — 时间（时间间隔） 内部程序；在固定地点 (S) 及固定地点以外 (P) 时间（时间间隔） 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/21","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"单模和多模光时域反射仪","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"400 ps to 100 ns","cmc":"4,6 · 10⁻⁴ ns"},{"name":"","range":"100 ns to 1 µs","cmc":"4,9 · 10⁻⁴ ns"},{"name":"","range":"1 µs to 10 µs","cmc":"7,0 · 10⁻⁴ ns"},{"name":"","range":"10 µs to 100 µs","cmc":"2,8 · 10⁻³ ns"},{"name":"","range":"100 µs to 1 ms","cmc":"2,4 · 10⁻² ns"},{"name":"","range":"1 ms to 10 ms","cmc":"2,3 · 10⁻¹ ns"},{"name":"","range":"10 ms to 100 ms","cmc":"2,3 ns"},{"name":"","range":"100 ms to 1 s","cmc":"23 ns"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Jednovidové a mnohovidové optické reflektometry Kalibrace — Čas (časový interval) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Čas (časový interval) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/21","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Jednovidové a mnohovidové optické reflektometry"},{"_id":"7beee15887acd3a2f40d1d7a","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Światłowodowe wzorce długości drogi optycznej\nOptyczne recyrkulacyjne linie opóźniające","test_object_en":"Optical fibre path length standards\nOptical recirculating delay lines","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"400 ps do 100 ns","cmc":"9,2 · 10⁻⁴ ns"},{"name":"","range":"100 ns do 1µs","cmc":"9,8 · 10⁻⁴ ns"},{"name":"","range":"1 µs do 10 µs","cmc":"14 · 10⁻⁴ ns"},{"name":"","range":"10 µs do 100 µs","cmc":"5,6 · 10⁻³ ns"},{"name":"","range":"100 µs do 1 ms","cmc":"5 · 10⁻² ns"}],"parameters_en":[{"name":"","range":"400 ps to 100 ns","cmc":"9,2 · 10⁻⁴ ns"},{"name":"","range":"100 ns to 1µs","cmc":"9,8 · 10⁻⁴ ns"},{"name":"","range":"1 µs to 10 µs","cmc":"14 · 10⁻⁴ ns"},{"name":"","range":"10 µs to 100 µs","cmc":"5,6 · 10⁻³ ns"},{"name":"","range":"100 µs to 1 ms","cmc":"5 · 10⁻² ns"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\n400 ps do 100 ns CMC 9,2 · 10⁻⁴ ns\n100 ns do 1µs CMC 9,8 · 10⁻⁴ ns\n1 µs do 10 µs CMC 14 · 10⁻⁴ ns\n10 µs do 100 µs CMC 5,6 · 10⁻³ ns\n100 µs do 1 ms CMC 5 · 10⁻² ns\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LMEEiO/47","norm_bases":["LMEEiO/47"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Światłowodowe wzorce długości drogi optycznej\nOptyczne recyrkulacyjne linie opóźniające Wzorcowanie — Czas (przedział czasu)\nZakres:\n400 ps do 100 ns CMC 9,2 · 10⁻⁴ ns\n100 ns do 1µs CMC 9,8 · 10⁻⁴ ns\n1 µs do 10 µs CMC 14 · 10⁻⁴ ns\n10 µs do 100 µs CMC 5,6 · 10⁻³ ns\n100 µs do 1 ms CMC 5 · 10⁻² ns\nProcedura wewnętrzna; W stałej lokalizacji (S) LMEEiO/47 Swiatlowodowe wzorce dlugosci drogi optycznej\nOptyczne recyrkulacyjne linie opozniajace Wzorcowanie — Czas (przedzial czasu)\nZakres:\n400 ps do 100 ns CMC 9,2 · 10⁻⁴ ns\n100 ns do 1µs CMC 9,8 · 10⁻⁴ ns\n1 µs do 10 µs CMC 14 · 10⁻⁴ ns\n10 µs do 100 µs CMC 5,6 · 10⁻³ ns\n100 µs do 1 ms CMC 5 · 10⁻² ns\nProcedura wewnetrzna; W stalej lokalizacji (S) LMEEiO/47","search_en":"Optical fibre path length standards Optical recirculating delay lines Calibration — Time (time interval) Internal procedure; At permanent location (S) Time (time interval) Internal procedure At permanent location (S) LMEEiO/47","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":57,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"400 ps to 100 ns","cmc":"9,2 · 10⁻⁴ ns"},{"name":"","range":"100 ns to 1µs","cmc":"9,8 · 10⁻⁴ ns"},{"name":"","range":"1 µs to 10 µs","cmc":"14 · 10⁻⁴ ns"},{"name":"","range":"10 µs to 100 µs","cmc":"5,6 · 10⁻³ ns"},{"name":"","range":"100 µs to 1 ms","cmc":"5 · 10⁻² ns"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Lichtwellenleiter-Normale der optischen Weglänge Optische Umlaufverzögerungsleitungen Kalibrierung — Zeit (Zeitintervall) Internes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Am festen Standort (S) LMEEiO/47","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Lichtwellenleiter-Normale der optischen Weglänge\nOptische Umlaufverzögerungsleitungen","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"400 ps to 100 ns","cmc":"9,2 · 10⁻⁴ ns"},{"name":"","range":"100 ns to 1µs","cmc":"9,8 · 10⁻⁴ ns"},{"name":"","range":"1 µs to 10 µs","cmc":"14 · 10⁻⁴ ns"},{"name":"","range":"10 µs to 100 µs","cmc":"5,6 · 10⁻³ ns"},{"name":"","range":"100 µs to 1 ms","cmc":"5 · 10⁻² ns"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"光纤光程长度标准 光学循环延迟线 校准 — 时间（时间间隔） 内部程序；在固定地点 (S) 时间（时间间隔） 内部程序 在固定地点 (S) LMEEiO/47","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"光纤光程长度标准\n光学循环延迟线","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"400 ps to 100 ns","cmc":"9,2 · 10⁻⁴ ns"},{"name":"","range":"100 ns to 1µs","cmc":"9,8 · 10⁻⁴ ns"},{"name":"","range":"1 µs to 10 µs","cmc":"14 · 10⁻⁴ ns"},{"name":"","range":"10 µs to 100 µs","cmc":"5,6 · 10⁻³ ns"},{"name":"","range":"100 µs to 1 ms","cmc":"5 · 10⁻² ns"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Vláknové etalony délky optické dráhy Optická recirkulační zpožďovací vedení Kalibrace — Čas (časový interval) Vnitřní postup; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Ve stálé lokalitě (S) LMEEiO/47","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Vláknové etalony délky optické dráhy\nOptická recirkulační zpožďovací vedení"},{"_id":"a234d1f1be7879e9e4dcc2eb","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki (testery) parametrów instalacji elektrycznej\nTestery wyłączników RCD","test_object_en":"Electrical installation parameter meters (testers)\nRCD testers","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"10 ms do 5000 ms","cmc":"0,02% + 0,25 ms"}],"parameters_en":[{"name":"","range":"10 ms to 5000 ms","cmc":"0,02% + 0,25 ms"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\n10 ms do 5000 ms CMC 0,02% + 0,25 ms\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/35","norm_bases":["LMEEiO/35"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki (testery) parametrów instalacji elektrycznej\nTestery wyłączników RCD Wzorcowanie — Czas (przedział czasu)\n10 ms do 5000 ms CMC 0,02% + 0,25 ms\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/35 Mierniki (testery) parametrow instalacji elektrycznej\nTestery wylacznikow RCD Wzorcowanie — Czas (przedzial czasu)\n10 ms do 5000 ms CMC 0,02% + 0,25 ms\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/35","search_en":"Electrical installation parameter meters (testers) RCD testers Calibration — Time (time interval) Internal procedure; At permanent location (S) and outside of it (P) Time (time interval) Internal procedure At permanent location (S) and outside of it (P) LMEEiO/35","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":58,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"10 ms to 5000 ms","cmc":"0,02% + 0,25 ms"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Messgeräte (Prüfgeräte) für Elektroinstallationsparameter RCD-Prüfgeräte Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Zeit (Zeitintervall) Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/35","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Messgeräte (Prüfgeräte) für Elektroinstallationsparameter\nRCD-Prüfgeräte","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"10 ms to 5000 ms","cmc":"0,02% + 0,25 ms"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"电气装置参数测量仪（测试仪） RCD 测试仪 校准 — 时间（时间间隔） 内部程序；在固定地点 (S) 及固定地点以外 (P) 时间（时间间隔） 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/35","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电气装置参数测量仪（测试仪）\nRCD 测试仪","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"10 ms to 5000 ms","cmc":"0,02% + 0,25 ms"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Měřiče (testery) parametrů elektrické instalace Testery proudových chráničů RCD Kalibrace — Čas (časový interval) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Čas (časový interval) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/35","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče (testery) parametrů elektrické instalace\nTestery proudových chráničů RCD"},{"_id":"3f69a5e08e7b306bfc762281","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki przedziału czasu","test_object_en":"Time interval meters","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"okres sygnału sinusoidalnego","range":"100 ps do 100 µs","cmc":"1·10⁻¹¹ · t dla czasu uśredniania ≥1s"},{"name":"okres sygnału prostokątnego; liczba uśrednianych okresów nie mniejsza niż 10","range":"10 ns do 10⁵ s","cmc":"1 · 10⁻¹¹ · t dla czasu uśredniania ≥1s"},{"name":"sygnał impulsowy lub prostokątny","range":"100 ps do 200 s","cmc":"50 ps + 1 · 10⁻¹¹ · t"},{"name":"sygnał impulsowy lub prostokątny","range":"200 s do 10⁵ s","cmc":"1 ns + 7 · 10⁻¹⁴ · t"}],"parameters_en":[{"name":"period of a sinusoidal signal","range":"100 ps to 100 µs","cmc":"1·10⁻¹¹ · t for averaging time ≥1s"},{"name":"period of a square wave signal; number of averaged periods not less than 10","range":"10 ns to 10⁵ s","cmc":"1 · 10⁻¹¹ · t for averaging time ≥1s"},{"name":"pulse or square wave signal","range":"100 ps to 200 s","cmc":"50 ps + 1 · 10⁻¹¹ · t"},{"name":"pulse or square wave signal","range":"200 s to 10⁵ s","cmc":"1 ns + 7 · 10⁻¹⁴ · t"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\nokres sygnału sinusoidalnego 100 ps do 100 µs CMC 1·10⁻¹¹ · t dla czasu uśredniania ≥1s\nokres sygnału prostokątnego; liczba uśrednianych okresów nie mniejsza niż 10 10 ns do 10⁵ s CMC 1 · 10⁻¹¹ · t dla czasu uśredniania ≥1s\nsygnał impulsowy lub prostokątny 100 ps do 200 s CMC 50 ps + 1 · 10⁻¹¹ · t\nsygnał impulsowy lub prostokątny 200 s do 10⁵ s CMC 1 ns + 7 · 10⁻¹⁴ · t\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LMEEiO/16","norm_bases":["LMEEiO/16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":"t – wielkość mierzona (s)","note_en":"t – measured value (s)","search_text":"Mierniki przedziału czasu Wzorcowanie — Czas (przedział czasu)\nZakres:\nokres sygnału sinusoidalnego 100 ps do 100 µs CMC 1·10⁻¹¹ · t dla czasu uśredniania ≥1s\nokres sygnału prostokątnego; liczba uśrednianych okresów nie mniejsza niż 10 10 ns do 10⁵ s CMC 1 · 10⁻¹¹ · t dla czasu uśredniania ≥1s\nsygnał impulsowy lub prostokątny 100 ps do 200 s CMC 50 ps + 1 · 10⁻¹¹ · t\nsygnał impulsowy lub prostokątny 200 s do 10⁵ s CMC 1 ns + 7 · 10⁻¹⁴ · t\nProcedura wewnętrzna; W stałej lokalizacji (S) LMEEiO/16 Mierniki przedzialu czasu Wzorcowanie — Czas (przedzial czasu)\nZakres:\nokres sygnalu sinusoidalnego 100 ps do 100 µs CMC 1·10⁻¹¹ · t dla czasu usredniania ≥1s\nokres sygnalu prostokatnego; liczba usrednianych okresow nie mniejsza niz 10 10 ns do 10⁵ s CMC 1 · 10⁻¹¹ · t dla czasu usredniania ≥1s\nsygnal impulsowy lub prostokatny 100 ps do 200 s CMC 50 ps + 1 · 10⁻¹¹ · t\nsygnal impulsowy lub prostokatny 200 s do 10⁵ s CMC 1 ns + 7 · 10⁻¹⁴ · t\nProcedura wewnetrzna; W stalej lokalizacji (S) LMEEiO/16","search_en":"Time interval meters Calibration — Time (time interval) Internal procedure; At permanent location (S) Time (time interval) Internal procedure At permanent location (S) period of a sinusoidal signal period of a square wave signal; number of averaged periods not less than 10 pulse or square wave signal pulse or square wave signal LMEEiO/16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":59,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"Periode eines Sinussignals","range":"100 ps to 100 µs","cmc":"1·10⁻¹¹ · t bei Mittelungszeit ≥1s"},{"name":"Periode eines Rechtecksignals; Anzahl der gemittelten Perioden nicht kleiner als 10","range":"10 ns to 10⁵ s","cmc":"1 · 10⁻¹¹ · t bei Mittelungszeit ≥1s"},{"name":"Impuls- oder Rechtecksignal","range":"100 ps to 200 s","cmc":"50 ps + 1 · 10⁻¹¹ · t"},{"name":"Impuls- oder Rechtecksignal","range":"200 s to 10⁵ s","cmc":"1 ns + 7 · 10⁻¹⁴ · t"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Zeitintervallmessgeräte Kalibrierung — Zeit (Zeitintervall) Internes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Am festen Standort (S) Periode eines Sinussignals Periode eines Rechtecksignals; Anzahl der gemittelten Perioden nicht kleiner als 10 Impuls- oder Rechtecksignal Impuls- oder Rechtecksignal LMEEiO/16","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Zeitintervallmessgeräte","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"正弦信号周期","range":"100 ps to 100 µs","cmc":"1·10⁻¹¹ · t，平均时间 ≥1s"},{"name":"方波信号周期; 平均周期数不少于 10","range":"10 ns to 10⁵ s","cmc":"1 · 10⁻¹¹ · t，平均时间 ≥1s"},{"name":"脉冲或方波信号","range":"100 ps to 200 s","cmc":"50 ps + 1 · 10⁻¹¹ · t"},{"name":"脉冲或方波信号","range":"200 s to 10⁵ s","cmc":"1 ns + 7 · 10⁻¹⁴ · t"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"时间间隔测量仪 校准 — 时间（时间间隔） 内部程序；在固定地点 (S) 时间（时间间隔） 内部程序 在固定地点 (S) 正弦信号周期 方波信号周期; 平均周期数不少于 10 脉冲或方波信号 脉冲或方波信号 LMEEiO/16","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"时间间隔测量仪","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"perioda sinusového signálu","range":"100 ps to 100 µs","cmc":"1·10⁻¹¹ · t při době průměrování ≥1s"},{"name":"perioda obdélníkového signálu; počet průměrovaných period nejméně 10","range":"10 ns to 10⁵ s","cmc":"1 · 10⁻¹¹ · t při době průměrování ≥1s"},{"name":"impulzní nebo obdélníkový signál","range":"100 ps to 200 s","cmc":"50 ps + 1 · 10⁻¹¹ · t"},{"name":"impulzní nebo obdélníkový signál","range":"200 s to 10⁵ s","cmc":"1 ns + 7 · 10⁻¹⁴ · t"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Měřiče časového intervalu Kalibrace — Čas (časový interval) Vnitřní postup; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Ve stálé lokalitě (S) perioda sinusového signálu perioda obdélníkového signálu; počet průměrovaných period nejméně 10 impulzní nebo obdélníkový signál impulzní nebo obdélníkový signál LMEEiO/16","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče časového intervalu"},{"_id":"9d3375838830945f1bf3e305","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki przedziału czasu","test_object_en":"Time interval meters","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"okres sygnału sinusoidalnego","range":"100 ps do 100 µs","cmc":"1·10⁻¹⁰ · t dla czasu uśredniania ≥1s"},{"name":"okres sygnału prostokątnego; liczba uśrednianych okresów nie mniejsza niż 10","range":"10 ns do 10⁵ s","cmc":"1 · 10⁻¹⁰ · t dla czasu uśredniania ≥1s"},{"name":"sygnał impulsowy lub prostokątny","range":"100 ps do 10⁵ s","cmc":"50 ps + 1 · 10⁻¹⁰ · t"}],"parameters_en":[{"name":"period of a sinusoidal signal","range":"100 ps to 100 µs","cmc":"1·10⁻¹⁰ · t for averaging time ≥1s"},{"name":"period of a square wave signal; number of averaged periods not less than 10","range":"10 ns to 10⁵ s","cmc":"1 · 10⁻¹⁰ · t for averaging time ≥1s"},{"name":"pulse or square wave signal","range":"100 ps to 10⁵ s","cmc":"50 ps + 1 · 10⁻¹⁰ · t"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\nokres sygnału sinusoidalnego 100 ps do 100 µs CMC 1·10⁻¹⁰ · t dla czasu uśredniania ≥1s\nokres sygnału prostokątnego; liczba uśrednianych okresów nie mniejsza niż 10 10 ns do 10⁵ s CMC 1 · 10⁻¹⁰ · t dla czasu uśredniania ≥1s\nsygnał impulsowy lub prostokątny 100 ps do 10⁵ s CMC 50 ps + 1 · 10⁻¹⁰ · t\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"LMEEiO/16","norm_bases":["LMEEiO/16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":true,"location_of_activity":"P","note":"t – wielkość mierzona (s)","note_en":"t – measured value (s)","search_text":"Mierniki przedziału czasu Wzorcowanie — Czas (przedział czasu)\nZakres:\nokres sygnału sinusoidalnego 100 ps do 100 µs CMC 1·10⁻¹⁰ · t dla czasu uśredniania ≥1s\nokres sygnału prostokątnego; liczba uśrednianych okresów nie mniejsza niż 10 10 ns do 10⁵ s CMC 1 · 10⁻¹⁰ · t dla czasu uśredniania ≥1s\nsygnał impulsowy lub prostokątny 100 ps do 10⁵ s CMC 50 ps + 1 · 10⁻¹⁰ · t\nProcedura wewnętrzna; Poza stałą lokalizacją (P) LMEEiO/16 Mierniki przedzialu czasu Wzorcowanie — Czas (przedzial czasu)\nZakres:\nokres sygnalu sinusoidalnego 100 ps do 100 µs CMC 1·10⁻¹⁰ · t dla czasu usredniania ≥1s\nokres sygnalu prostokatnego; liczba usrednianych okresow nie mniejsza niz 10 10 ns do 10⁵ s CMC 1 · 10⁻¹⁰ · t dla czasu usredniania ≥1s\nsygnal impulsowy lub prostokatny 100 ps do 10⁵ s CMC 50 ps + 1 · 10⁻¹⁰ · t\nProcedura wewnetrzna; Poza stala lokalizacja (P) LMEEiO/16","search_en":"Time interval meters Calibration — Time (time interval) Internal procedure; Outside of permanent location (P) Time (time interval) Internal procedure Outside of permanent location (P) period of a sinusoidal signal period of a square wave signal; number of averaged periods not less than 10 pulse or square wave signal LMEEiO/16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":60,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"Periode eines Sinussignals","range":"100 ps to 100 µs","cmc":"1·10⁻¹⁰ · t bei Mittelungszeit ≥1s"},{"name":"Periode eines Rechtecksignals; Anzahl der gemittelten Perioden nicht kleiner als 10","range":"10 ns to 10⁵ s","cmc":"1 · 10⁻¹⁰ · t bei Mittelungszeit ≥1s"},{"name":"Impuls- oder Rechtecksignal","range":"100 ps to 10⁵ s","cmc":"50 ps + 1 · 10⁻¹⁰ · t"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Zeitintervallmessgeräte Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Zeit (Zeitintervall) Internes Verfahren Außerhalb des festen Standorts (P) Periode eines Sinussignals Periode eines Rechtecksignals; Anzahl der gemittelten Perioden nicht kleiner als 10 Impuls- oder Rechtecksignal LMEEiO/16","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Zeitintervallmessgeräte","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"正弦信号周期","range":"100 ps to 100 µs","cmc":"1·10⁻¹⁰ · t，平均时间 ≥1s"},{"name":"方波信号周期; 平均周期数不少于 10","range":"10 ns to 10⁵ s","cmc":"1 · 10⁻¹⁰ · t，平均时间 ≥1s"},{"name":"脉冲或方波信号","range":"100 ps to 10⁵ s","cmc":"50 ps + 1 · 10⁻¹⁰ · t"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"时间间隔测量仪 校准 — 时间（时间间隔） 内部程序；固定地点以外 (P) 时间（时间间隔） 内部程序 固定地点以外 (P) 正弦信号周期 方波信号周期; 平均周期数不少于 10 脉冲或方波信号 LMEEiO/16","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"时间间隔测量仪","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"perioda sinusového signálu","range":"100 ps to 100 µs","cmc":"1·10⁻¹⁰ · t při době průměrování ≥1s"},{"name":"perioda obdélníkového signálu; počet průměrovaných period nejméně 10","range":"10 ns to 10⁵ s","cmc":"1 · 10⁻¹⁰ · t při době průměrování ≥1s"},{"name":"impulzní nebo obdélníkový signál","range":"100 ps to 10⁵ s","cmc":"50 ps + 1 · 10⁻¹⁰ · t"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Měřiče časového intervalu Kalibrace — Čas (časový interval) Vnitřní postup; Mimo stálé pracoviště (P) Čas (časový interval) Vnitřní postup Mimo stálou lokalitu (P) perioda sinusového signálu perioda obdélníkového signálu; počet průměrovaných period nejméně 10 impulzní nebo obdélníkový signál LMEEiO/16","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Měřiče časového intervalu"},{"_id":"e4a4c3eedb4cb918c3f50f09","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki przedziału czasu","test_object_en":"Time interval meters","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"okres sygnału sinusoidalnego","range":"100 ps do 100 µs","cmc":"3·10⁻¹⁰ · t dla czasu uśredniania ≥ 0,1s"},{"name":"okres sygnału sinusoidalnego","range":"100 ps do 100 µs","cmc":"0,03 ns dla czasu uśredniania < 0,1 s"},{"name":"okres sygnału sinusoidalnego","range":"100 µs do 1 ms","cmc":"1·10⁻¹⁰ · t"},{"name":"okres sygnału sinusoidalnego","range":"1 ms do 10 ms","cmc":"1·10⁻⁹ · t"},{"name":"okres sygnału sinusoidalnego","range":"10 ms do 1 s","cmc":"5·10⁻⁸ · t"},{"name":"okres sygnału sinusoidalnego","range":"1 s do 10 s","cmc":"1 · 10⁻⁷ · t"}],"parameters_en":[{"name":"period of a sinusoidal signal","range":"100 ps to 100 µs","cmc":"3·10⁻¹⁰ · t for averaging time ≥ 0,1s"},{"name":"period of a sinusoidal signal","range":"100 ps to 100 µs","cmc":"0,03 ns for averaging time < 0,1 s"},{"name":"period of a sinusoidal signal","range":"100 µs to 1 ms","cmc":"1·10⁻¹⁰ · t"},{"name":"period of a sinusoidal signal","range":"1 ms to 10 ms","cmc":"1·10⁻⁹ · t"},{"name":"period of a sinusoidal signal","range":"10 ms to 1 s","cmc":"5·10⁻⁸ · t"},{"name":"period of a sinusoidal signal","range":"1 s to 10 s","cmc":"1 · 10⁻⁷ · t"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\nokres sygnału sinusoidalnego 100 ps do 100 µs CMC 3·10⁻¹⁰ · t dla czasu uśredniania ≥ 0,1s\nokres sygnału sinusoidalnego 100 ps do 100 µs CMC 0,03 ns dla czasu uśredniania < 0,1 s\nokres sygnału sinusoidalnego 100 µs do 1 ms CMC 1·10⁻¹⁰ · t\nokres sygnału sinusoidalnego 1 ms do 10 ms CMC 1·10⁻⁹ · t\nokres sygnału sinusoidalnego 10 ms do 1 s CMC 5·10⁻⁸ · t\nokres sygnału sinusoidalnego 1 s do 10 s CMC 1 · 10⁻⁷ · t\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/16","norm_bases":["LMEEiO/16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":true,"location_of_activity":"S, P","note":"t – wielkość mierzona (s)","note_en":"t – measured value (s)","search_text":"Mierniki przedziału czasu Wzorcowanie — Czas (przedział czasu)\nZakres:\nokres sygnału sinusoidalnego 100 ps do 100 µs CMC 3·10⁻¹⁰ · t dla czasu uśredniania ≥ 0,1s\nokres sygnału sinusoidalnego 100 ps do 100 µs CMC 0,03 ns dla czasu uśredniania < 0,1 s\nokres sygnału sinusoidalnego 100 µs do 1 ms CMC 1·10⁻¹⁰ · t\nokres sygnału sinusoidalnego 1 ms do 10 ms CMC 1·10⁻⁹ · t\nokres sygnału sinusoidalnego 10 ms do 1 s CMC 5·10⁻⁸ · t\nokres sygnału sinusoidalnego 1 s do 10 s CMC 1 · 10⁻⁷ · t\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/16 Mierniki przedzialu czasu Wzorcowanie — Czas (przedzial czasu)\nZakres:\nokres sygnalu sinusoidalnego 100 ps do 100 µs CMC 3·10⁻¹⁰ · t dla czasu usredniania ≥ 0,1s\nokres sygnalu sinusoidalnego 100 ps do 100 µs CMC 0,03 ns dla czasu usredniania < 0,1 s\nokres sygnalu sinusoidalnego 100 µs do 1 ms CMC 1·10⁻¹⁰ · t\nokres sygnalu sinusoidalnego 1 ms do 10 ms CMC 1·10⁻⁹ · t\nokres sygnalu sinusoidalnego 10 ms do 1 s CMC 5·10⁻⁸ · t\nokres sygnalu sinusoidalnego 1 s do 10 s CMC 1 · 10⁻⁷ · t\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/16","search_en":"Time interval meters Calibration — Time (time interval) Internal procedure; At permanent location (S) and outside of it (P) Time (time interval) Internal procedure At permanent location (S) and outside of it (P) period of a sinusoidal signal period of a sinusoidal signal period of a sinusoidal signal period of a sinusoidal signal period of a sinusoidal signal period of a sinusoidal signal LMEEiO/16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":61,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"Periode eines Sinussignals","range":"100 ps to 100 µs","cmc":"3·10⁻¹⁰ · t bei Mittelungszeit ≥ 0,1s"},{"name":"Periode eines Sinussignals","range":"100 ps to 100 µs","cmc":"0,03 ns bei Mittelungszeit < 0,1 s"},{"name":"Periode eines Sinussignals","range":"100 µs to 1 ms","cmc":"1·10⁻¹⁰ · t"},{"name":"Periode eines Sinussignals","range":"1 ms to 10 ms","cmc":"1·10⁻⁹ · t"},{"name":"Periode eines Sinussignals","range":"10 ms to 1 s","cmc":"5·10⁻⁸ · t"},{"name":"Periode eines Sinussignals","range":"1 s to 10 s","cmc":"1 · 10⁻⁷ · t"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Zeitintervallmessgeräte Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Zeit (Zeitintervall) Internes Verfahren Am festen Standort (S) und außerhalb (P) Periode eines Sinussignals Periode eines Sinussignals Periode eines Sinussignals Periode eines Sinussignals Periode eines Sinussignals Periode eines Sinussignals LMEEiO/16","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Zeitintervallmessgeräte","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"正弦信号周期","range":"100 ps to 100 µs","cmc":"3·10⁻¹⁰ · t，平均时间 ≥ 0,1s"},{"name":"正弦信号周期","range":"100 ps to 100 µs","cmc":"0,03 ns，平均时间 < 0,1 s"},{"name":"正弦信号周期","range":"100 µs to 1 ms","cmc":"1·10⁻¹⁰ · t"},{"name":"正弦信号周期","range":"1 ms to 10 ms","cmc":"1·10⁻⁹ · t"},{"name":"正弦信号周期","range":"10 ms to 1 s","cmc":"5·10⁻⁸ · t"},{"name":"正弦信号周期","range":"1 s to 10 s","cmc":"1 · 10⁻⁷ · t"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"时间间隔测量仪 校准 — 时间（时间间隔） 内部程序；在固定地点 (S) 及固定地点以外 (P) 时间（时间间隔） 内部程序 在固定地点 (S) 及固定地点以外 (P) 正弦信号周期 正弦信号周期 正弦信号周期 正弦信号周期 正弦信号周期 正弦信号周期 LMEEiO/16","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"时间间隔测量仪","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"perioda sinusového signálu","range":"100 ps to 100 µs","cmc":"3·10⁻¹⁰ · t při době průměrování ≥ 0,1s"},{"name":"perioda sinusového signálu","range":"100 ps to 100 µs","cmc":"0,03 ns při době průměrování < 0,1 s"},{"name":"perioda sinusového signálu","range":"100 µs to 1 ms","cmc":"1·10⁻¹⁰ · t"},{"name":"perioda sinusového signálu","range":"1 ms to 10 ms","cmc":"1·10⁻⁹ · t"},{"name":"perioda sinusového signálu","range":"10 ms to 1 s","cmc":"5·10⁻⁸ · t"},{"name":"perioda sinusového signálu","range":"1 s to 10 s","cmc":"1 · 10⁻⁷ · t"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Měřiče časového intervalu Kalibrace — Čas (časový interval) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Čas (časový interval) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) perioda sinusového signálu perioda sinusového signálu perioda sinusového signálu perioda sinusového signálu perioda sinusového signálu perioda sinusového signálu LMEEiO/16","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče časového intervalu"},{"_id":"5eaf0b63e6e9f9e73412a182","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Oscyloskopy\nSkopometry","test_object_en":"Oscilloscopes\nScopemeters","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"909,1 ps do 55 s","cmc":"10 ps + 0,3 · 10⁻⁶ · t"}],"parameters_en":[{"name":"","range":"909,1 ps to 55 s","cmc":"10 ps + 0,3 · 10⁻⁶ · t"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\n909,1 ps do 55 s CMC 10 ps + 0,3 · 10⁻⁶ · t\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/13","norm_bases":["LMEEiO/13"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":true,"location_of_activity":"S, P","note":"t – wielkość mierzona (s)","note_en":"t – measured value (s)","search_text":"Oscyloskopy\nSkopometry Wzorcowanie — Czas (przedział czasu)\n909,1 ps do 55 s CMC 10 ps + 0,3 · 10⁻⁶ · t\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/13 Oscyloskopy\nSkopometry Wzorcowanie — Czas (przedzial czasu)\n909,1 ps do 55 s CMC 10 ps + 0,3 · 10⁻⁶ · t\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/13","search_en":"Oscilloscopes Scopemeters Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) and outside of it (P) Time (time interval) Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/13","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":62,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"909,1 ps to 55 s","cmc":"10 ps + 0,3 · 10⁻⁶ · t"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Oszilloskope Scopemeter Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/13","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Oszilloskope\nScopemeter","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"909,1 ps to 55 s","cmc":"10 ps + 0,3 · 10⁻⁶ · t"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"示波器 手持示波表 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/13","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"示波器\n手持示波表","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"909,1 ps to 55 s","cmc":"10 ps + 0,3 · 10⁻⁶ · t"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Osciloskopy Skopmetry Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Čas (časový interval) Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/13","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Osciloskopy\nSkopmetry"},{"_id":"c1d2a1e93f42f4684b315094","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory parametrów i uszkodzeń linii","test_object_en":"Line parameter and fault analysers","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"5 ns do 1600 ns","cmc":"10 %"}],"parameters_en":[{"name":"","range":"5 ns to 1600 ns","cmc":"10 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\n5 ns do 1600 ns CMC 10 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/42","norm_bases":["LMEEiO/42"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Analizatory parametrów i uszkodzeń linii Wzorcowanie — Czas (przedział czasu)\n5 ns do 1600 ns CMC 10 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/42 Analizatory parametrow i uszkodzen linii Wzorcowanie — Czas (przedzial czasu)\n5 ns do 1600 ns CMC 10 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/42","search_en":"Line parameter and fault analysers Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) LMEEiO/42","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":63,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"5 ns to 1600 ns","cmc":"10 %"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Leitungsparameter- und Fehleranalysatoren Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) LMEEiO/42","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Leitungsparameter- und Fehleranalysatoren","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"5 ns to 1600 ns","cmc":"10 %"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"线路参数与故障分析仪 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) LMEEiO/42","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"线路参数与故障分析仪","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"5 ns to 1600 ns","cmc":"10 %"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Analyzátory parametrů a poruch vedení Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LMEEiO/42","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analyzátory parametrů a poruch vedení"},{"_id":"9cf3aedc4642a55d8b2b49b1","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Czas fazowy\nMierniki błędu przedziału czasu (TIE)\nKomparatory czasu fazowego","test_object_en":"Phase time\nTime interval error meters (TIE)\nPhase time comparators","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"2,048 MHz","range":"1 ns do 100 ms","cmc":"0,1 ns + 5 · 10⁻¹⁰ TIE"},{"name":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","range":"1 ns do 1 s","cmc":"0,1 ns + 5 · 10⁻¹⁰ · x"},{"name":"1 Hz","range":"1 ns do 1 s","cmc":"0,5 ns"}],"parameters_en":[{"name":"2,048 MHz","range":"1 ns to 100 ms","cmc":"0,1 ns + 5 · 10⁻¹⁰ TIE"},{"name":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","range":"1 ns to 1 s","cmc":"0,1 ns + 5 · 10⁻¹⁰ · x"},{"name":"1 Hz","range":"1 ns to 1 s","cmc":"0,5 ns"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\n2,048 MHz 1 ns do 100 ms CMC 0,1 ns + 5 · 10⁻¹⁰ TIE\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz 1 ns do 1 s CMC 0,1 ns + 5 · 10⁻¹⁰ · x\n1 Hz 1 ns do 1 s CMC 0,5 ns\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LMEEiO/17","norm_bases":["LMEEiO/17"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":"x – czas fazowy","note_en":"x – phase time","search_text":"Czas fazowy\nMierniki błędu przedziału czasu (TIE)\nKomparatory czasu fazowego Wzorcowanie — Czas (przedział czasu)\nZakres:\n2,048 MHz 1 ns do 100 ms CMC 0,1 ns + 5 · 10⁻¹⁰ TIE\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz 1 ns do 1 s CMC 0,1 ns + 5 · 10⁻¹⁰ · x\n1 Hz 1 ns do 1 s CMC 0,5 ns\nProcedura wewnętrzna; W stałej lokalizacji (S) LMEEiO/17 Czas fazowy\nMierniki bledu przedzialu czasu (TIE)\nKomparatory czasu fazowego Wzorcowanie — Czas (przedzial czasu)\nZakres:\n2,048 MHz 1 ns do 100 ms CMC 0,1 ns + 5 · 10⁻¹⁰ TIE\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz 1 ns do 1 s CMC 0,1 ns + 5 · 10⁻¹⁰ · x\n1 Hz 1 ns do 1 s CMC 0,5 ns\nProcedura wewnetrzna; W stalej lokalizacji (S) LMEEiO/17","search_en":"Phase time Time interval error meters (TIE) Phase time comparators Calibration — Time (time interval) Internal procedure; At permanent location (S) Time (time interval) Internal procedure At permanent location (S) 2,048 MHz 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz 1 Hz LMEEiO/17","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":64,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"2,048 MHz","range":"1 ns to 100 ms","cmc":"0,1 ns + 5 · 10⁻¹⁰ TIE"},{"name":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","range":"1 ns to 1 s","cmc":"0,1 ns + 5 · 10⁻¹⁰ · x"},{"name":"1 Hz","range":"1 ns to 1 s","cmc":"0,5 ns"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Phasenzeit Zeitintervallfehler-Messgeräte (TIE) Phasenzeitkomparatoren Kalibrierung — Zeit (Zeitintervall) Internes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Am festen Standort (S) 2,048 MHz 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz 1 Hz LMEEiO/17","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Phasenzeit\nZeitintervallfehler-Messgeräte (TIE)\nPhasenzeitkomparatoren","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"2,048 MHz","range":"1 ns to 100 ms","cmc":"0,1 ns + 5 · 10⁻¹⁰ TIE"},{"name":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","range":"1 ns to 1 s","cmc":"0,1 ns + 5 · 10⁻¹⁰ · x"},{"name":"1 Hz","range":"1 ns to 1 s","cmc":"0,5 ns"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"相位时间 时间间隔误差测量仪（TIE） 相位时间比较器 校准 — 时间（时间间隔） 内部程序；在固定地点 (S) 时间（时间间隔） 内部程序 在固定地点 (S) 2,048 MHz 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz 1 Hz LMEEiO/17","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"相位时间\n时间间隔误差测量仪（TIE）\n相位时间比较器","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"2,048 MHz","range":"1 ns to 100 ms","cmc":"0,1 ns + 5 · 10⁻¹⁰ TIE"},{"name":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","range":"1 ns to 1 s","cmc":"0,1 ns + 5 · 10⁻¹⁰ · x"},{"name":"1 Hz","range":"1 ns to 1 s","cmc":"0,5 ns"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Fázový čas Měřiče chyby časového intervalu (TIE) Komparátory fázového času Kalibrace — Čas (časový interval) Vnitřní postup; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Ve stálé lokalitě (S) 2,048 MHz 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz 1 Hz LMEEiO/17","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Fázový čas\nMěřiče chyby časového intervalu (TIE)\nKomparátory fázového času"},{"_id":"7db0a4b5b2e7525aa27569a0","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki fluktuacji czasu fazowego zawarte w odbiornikach Analizatorów/testerów PDH/SDH (wartości międzyszczytowe sygnału)","test_object_en":"Phase time fluctuation (jitter) meters included in receivers of PDH/SDH analysers/testers (peak-to-peak signal values)","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"Dla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 2,048 Mb/s","range":"0 UI do 21,751 UI","cmc":"0,003 UI"},{"name":"Dla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 8,448 Mb/s","range":"0 UI do 21,751 UI","cmc":"0,003 UI"},{"name":"Dla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 34,648 Mb/s","range":"0 UI do 21,751 UI","cmc":"0,003 UI"},{"name":"Dla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 139,264 Mb/s","range":"0 UI do 21,751 UI","cmc":"0,003 UI"},{"name":"Dla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 155,520 Mb/s","range":"0 UI do 21,751 UI","cmc":"0,03 UI"},{"name":"Dla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 622,080 Mb/s","range":"0 UI do 256 UI","cmc":"8 % w.mierz + 0,02 UI"},{"name":"","range":"Dla wartości częstotliwości fluktuacji czasu fazowego 100 Hz, 1 kHz, 10kHz, 100 kHz zakresów j.w. przepływności Sygnałów","cmc":"0,003 UI do 0,03 UI"},{"name":"","range":"Dla wartości częstotliwości fluktuacji czasu fazowego 2 Hz do 20 MHz zakresów j.w. przepływności sygnałów","cmc":"(8 % do 15 %) w. mierz 0,02 UI"}],"parameters_en":[{"name":"For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 2,048 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 8,448 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 34,648 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 139,264 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 155,520 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,03 UI"},{"name":"For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 622,080 Mb/s","range":"0 UI to 256 UI","cmc":"8 % of measured value + 0,02 UI"},{"name":"","range":"For phase time fluctuation frequencies 100 Hz, 1 kHz, 10kHz, 100 kHz ranges and bit rates as above","cmc":"0,003 UI do 0,03 UI"},{"name":"","range":"For phase time fluctuation frequencies 2 Hz to 20 MHz, ranges and bit rates as above","cmc":"(8 % do 15 %) w. mierz 0,02 UI"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 2,048 Mb/s 0 UI do 21,751 UI CMC 0,003 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 8,448 Mb/s 0 UI do 21,751 UI CMC 0,003 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 34,648 Mb/s 0 UI do 21,751 UI CMC 0,003 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 139,264 Mb/s 0 UI do 21,751 UI CMC 0,003 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 155,520 Mb/s 0 UI do 21,751 UI CMC 0,03 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 622,080 Mb/s 0 UI do 256 UI CMC 8 % w.mierz + 0,02 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 100 Hz, 1 kHz, 10kHz, 100 kHz zakresów j.w. przepływności Sygnałów CMC 0,003 UI do 0,03 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 2 Hz do 20 MHz zakresów j.w. przepływności sygnałów CMC (8 % do 15 %) w. mierz 0,02 UI\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/30\nLMEEiO/27","norm_bases":["LMEEiO/30","LMEEiO/27"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki fluktuacji czasu fazowego zawarte w odbiornikach Analizatorów/testerów PDH/SDH (wartości międzyszczytowe sygnału) Wzorcowanie — Czas (przedział czasu)\nZakres:\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 2,048 Mb/s 0 UI do 21,751 UI CMC 0,003 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 8,448 Mb/s 0 UI do 21,751 UI CMC 0,003 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 34,648 Mb/s 0 UI do 21,751 UI CMC 0,003 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 139,264 Mb/s 0 UI do 21,751 UI CMC 0,003 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 155,520 Mb/s 0 UI do 21,751 UI CMC 0,03 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 622,080 Mb/s 0 UI do 256 UI CMC 8 % w.mierz + 0,02 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 100 Hz, 1 kHz, 10kHz, 100 kHz zakresów j.w. przepływności Sygnałów CMC 0,003 UI do 0,03 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 2 Hz do 20 MHz zakresów j.w. przepływności sygnałów CMC (8 % do 15 %) w. mierz 0,02 UI\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/30\nLMEEiO/27 Mierniki fluktuacji czasu fazowego zawarte w odbiornikach Analizatorow/testerow PDH/SDH (wartosci miedzyszczytowe sygnalu) Wzorcowanie — Czas (przedzial czasu)\nZakres:\nDla wartosci czestotliwosci fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 2,048 Mb/s 0 UI do 21,751 UI CMC 0,003 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 8,448 Mb/s 0 UI do 21,751 UI CMC 0,003 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 34,648 Mb/s 0 UI do 21,751 UI CMC 0,003 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 139,264 Mb/s 0 UI do 21,751 UI CMC 0,003 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 155,520 Mb/s 0 UI do 21,751 UI CMC 0,03 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 622,080 Mb/s 0 UI do 256 UI CMC 8 % w.mierz + 0,02 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 100 Hz, 1 kHz, 10kHz, 100 kHz zakresow j.w. przeplywnosci Sygnalow CMC 0,003 UI do 0,03 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 2 Hz do 20 MHz zakresow j.w. przeplywnosci sygnalow CMC (8 % do 15 %) w. mierz 0,02 UI\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/30\nLMEEiO/27","search_en":"Phase time fluctuation (jitter) meters included in receivers of PDH/SDH analysers/testers (peak-to-peak signal values) Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 2,048 Mb/s For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 8,448 Mb/s For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 34,648 Mb/s For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 139,264 Mb/s For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 155,520 Mb/s For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 622,080 Mb/s LMEEiO/30 LMEEiO/27","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":65,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 2,048 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 8,448 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 34,648 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 139,264 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 155,520 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,03 UI"},{"name":"Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 622,080 Mb/s","range":"0 UI to 256 UI","cmc":"8 % des Messwerts + 0,02 UI"},{"name":"","range":"For phase time fluctuation frequencies 100 Hz, 1 kHz, 10kHz, 100 kHz ranges and bit rates as above","cmc":"0,003 UI do 0,03 UI"},{"name":"","range":"For phase time fluctuation frequencies 2 Hz to 20 MHz, ranges and bit rates as above","cmc":"(8 % do 15 %) w. mierz 0,02 UI"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Messgeräte für Phasenzeitschwankungen (Jitter) in Empfängern von PDH/SDH-Analysatoren/-Testern (Spitze-Spitze-Werte des Signals) Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 2,048 Mb/s Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 8,448 Mb/s Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 34,648 Mb/s Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 139,264 Mb/s Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 155,520 Mb/s Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 622,080 Mb/s LMEEiO/30 LMEEiO/27","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Messgeräte für Phasenzeitschwankungen (Jitter) in Empfängern von PDH/SDH-Analysatoren/-Testern (Spitze-Spitze-Werte des Signals)","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 2,048 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 8,448 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 34,648 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 139,264 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 155,520 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,03 UI"},{"name":"相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 622,080 Mb/s","range":"0 UI to 256 UI","cmc":"8 % 测量值 + 0,02 UI"},{"name":"","range":"For phase time fluctuation frequencies 100 Hz, 1 kHz, 10kHz, 100 kHz ranges and bit rates as above","cmc":"0,003 UI do 0,03 UI"},{"name":"","range":"For phase time fluctuation frequencies 2 Hz to 20 MHz, ranges and bit rates as above","cmc":"(8 % do 15 %) w. mierz 0,02 UI"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"PDH/SDH 分析仪/测试仪接收机中的相位时间波动（抖动）测量仪（信号峰峰值） 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) 相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 2,048 Mb/s 相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 8,448 Mb/s 相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 34,648 Mb/s 相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 139,264 Mb/s 相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 155,520 Mb/s 相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 622,080 Mb/s LMEEiO/30 LMEEiO/27","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"PDH/SDH 分析仪/测试仪接收机中的相位时间波动（抖动）测量仪（信号峰峰值）","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 2,048 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 8,448 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 34,648 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 139,264 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,003 UI"},{"name":"Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 155,520 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,03 UI"},{"name":"Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 622,080 Mb/s","range":"0 UI to 256 UI","cmc":"8 % měř. hodnoty + 0,02 UI"},{"name":"","range":"For phase time fluctuation frequencies 100 Hz, 1 kHz, 10kHz, 100 kHz ranges and bit rates as above","cmc":"0,003 UI do 0,03 UI"},{"name":"","range":"For phase time fluctuation frequencies 2 Hz to 20 MHz, ranges and bit rates as above","cmc":"(8 % do 15 %) w. mierz 0,02 UI"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Měřiče fluktuace fázového času obsažené v přijímačích analyzátorů/testerů PDH/SDH (mezivrcholové hodnoty signálu) Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 2,048 Mb/s Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 8,448 Mb/s Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 34,648 Mb/s Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 139,264 Mb/s Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 155,520 Mb/s Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 622,080 Mb/s LMEEiO/30 LMEEiO/27","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče fluktuace fázového času obsažené v přijímačích analyzátorů/testerů PDH/SDH (mezivrcholové hodnoty signálu)"},{"_id":"2be94da4ce753f22fe0c5213","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory fluktuacji czasu fazowego zawarte w nadajnikach Analizatorów/testerów PDH/SDH (wartości międzyszczytowe sygnału)","test_object_en":"Phase time fluctuation (jitter) generators included in transmitters of PDH/SDH analysers/testers (peak-to-peak signal values)","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"Dla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 2,048 Mb/s","range":"0 UI do 21,751 UI","cmc":"0,002 UI"},{"name":"Dla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 8,448 Mb/s","range":"0 UI do 21,751 UI","cmc":"0,002 UI"},{"name":"Dla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 34,648 Mb/s","range":"0 UI do 21,751 UI","cmc":"0,002 UI"},{"name":"Dla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 139,264 Mb/s","range":"0 UI do 21,751 UI","cmc":"0,002 UI"},{"name":"Dla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 155,520 Mb/s","range":"0 UI do 21,751 UI","cmc":"0,02 UI"},{"name":"Dla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 622,080 Mb/s","range":"0 UI do 800 UI","cmc":"5 % w.mierz + 0,07 UI"},{"name":"","range":"Dla wartości częstotliwości fluktuacji czasu fazowego 100 Hz, 1 kHz, 10 kHz, 100 kHz zakresów j.w. przepływności sygnałów","cmc":"0,002 UI do 0,02 UI"},{"name":"","range":"Dla wartości częstotliwości fluktuacji czasu fazowego 2 Hz do 20 MHz, zakresów j.w. przepływności sygnałów","cmc":"(5 % do 19 %) w. mierz 0,024 UI do 0,2 UI"}],"parameters_en":[{"name":"For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 2,048 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 8,448 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 34,648 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 139,264 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 155,520 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,02 UI"},{"name":"For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 622,080 Mb/s","range":"0 UI to 800 UI","cmc":"5 % of measured value + 0,07 UI"},{"name":"","range":"For phase time fluctuation frequencies 100 Hz, 1 kHz, 10 kHz, 100 kHz ranges and bit rates as above","cmc":"0,002 UI do 0,02 UI"},{"name":"","range":"For phase time fluctuation frequencies 2 Hz to 20 MHz, ranges and bit rates as above","cmc":"(5 % do 19 %) w. mierz 0,024 UI do 0,2 UI"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 2,048 Mb/s 0 UI do 21,751 UI CMC 0,002 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 8,448 Mb/s 0 UI do 21,751 UI CMC 0,002 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 34,648 Mb/s 0 UI do 21,751 UI CMC 0,002 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 139,264 Mb/s 0 UI do 21,751 UI CMC 0,002 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 155,520 Mb/s 0 UI do 21,751 UI CMC 0,02 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 622,080 Mb/s 0 UI do 800 UI CMC 5 % w.mierz + 0,07 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 100 Hz, 1 kHz, 10 kHz, 100 kHz zakresów j.w. przepływności sygnałów CMC 0,002 UI do 0,02 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 2 Hz do 20 MHz, zakresów j.w. przepływności sygnałów CMC (5 % do 19 %) w. mierz 0,024 UI do 0,2 UI\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/30\nLMEEiO/27","norm_bases":["LMEEiO/30","LMEEiO/27"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Generatory fluktuacji czasu fazowego zawarte w nadajnikach Analizatorów/testerów PDH/SDH (wartości międzyszczytowe sygnału) Wzorcowanie — Czas (przedział czasu)\nZakres:\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 2,048 Mb/s 0 UI do 21,751 UI CMC 0,002 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 8,448 Mb/s 0 UI do 21,751 UI CMC 0,002 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 34,648 Mb/s 0 UI do 21,751 UI CMC 0,002 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 139,264 Mb/s 0 UI do 21,751 UI CMC 0,002 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 155,520 Mb/s 0 UI do 21,751 UI CMC 0,02 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 622,080 Mb/s 0 UI do 800 UI CMC 5 % w.mierz + 0,07 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 100 Hz, 1 kHz, 10 kHz, 100 kHz zakresów j.w. przepływności sygnałów CMC 0,002 UI do 0,02 UI\nDla wartości częstotliwości fluktuacji czasu fazowego 2 Hz do 20 MHz, zakresów j.w. przepływności sygnałów CMC (5 % do 19 %) w. mierz 0,024 UI do 0,2 UI\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/30\nLMEEiO/27 Generatory fluktuacji czasu fazowego zawarte w nadajnikach Analizatorow/testerow PDH/SDH (wartosci miedzyszczytowe sygnalu) Wzorcowanie — Czas (przedzial czasu)\nZakres:\nDla wartosci czestotliwosci fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 2,048 Mb/s 0 UI do 21,751 UI CMC 0,002 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 8,448 Mb/s 0 UI do 21,751 UI CMC 0,002 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 34,648 Mb/s 0 UI do 21,751 UI CMC 0,002 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 139,264 Mb/s 0 UI do 21,751 UI CMC 0,002 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 155,520 Mb/s 0 UI do 21,751 UI CMC 0,02 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 1 kHz (PDH) i 100 kHz (SDH); 622,080 Mb/s 0 UI do 800 UI CMC 5 % w.mierz + 0,07 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 100 Hz, 1 kHz, 10 kHz, 100 kHz zakresow j.w. przeplywnosci sygnalow CMC 0,002 UI do 0,02 UI\nDla wartosci czestotliwosci fluktuacji czasu fazowego 2 Hz do 20 MHz, zakresow j.w. przeplywnosci sygnalow CMC (5 % do 19 %) w. mierz 0,024 UI do 0,2 UI\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/30\nLMEEiO/27","search_en":"Phase time fluctuation (jitter) generators included in transmitters of PDH/SDH analysers/testers (peak-to-peak signal values) Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 2,048 Mb/s For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 8,448 Mb/s For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 34,648 Mb/s For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 139,264 Mb/s For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 155,520 Mb/s For phase time fluctuation frequencies 1 kHz (PDH) and 100 kHz (SDH); 622,080 Mb/s LMEEiO/30 LMEEiO/27","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":66,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 2,048 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 8,448 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 34,648 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 139,264 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 155,520 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,02 UI"},{"name":"Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 622,080 Mb/s","range":"0 UI to 800 UI","cmc":"5 % des Messwerts + 0,07 UI"},{"name":"","range":"For phase time fluctuation frequencies 100 Hz, 1 kHz, 10 kHz, 100 kHz ranges and bit rates as above","cmc":"0,002 UI do 0,02 UI"},{"name":"","range":"For phase time fluctuation frequencies 2 Hz to 20 MHz, ranges and bit rates as above","cmc":"(5 % do 19 %) w. mierz 0,024 UI do 0,2 UI"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Generatoren für Phasenzeitschwankungen (Jitter) in Sendern von PDH/SDH-Analysatoren/-Testern (Spitze-Spitze-Werte des Signals) Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 2,048 Mb/s Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 8,448 Mb/s Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 34,648 Mb/s Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 139,264 Mb/s Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 155,520 Mb/s Für Phasenzeit-Schwankungsfrequenzen 1 kHz (PDH) und 100 kHz (SDH); 622,080 Mb/s LMEEiO/30 LMEEiO/27","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Generatoren für Phasenzeitschwankungen (Jitter) in Sendern von PDH/SDH-Analysatoren/-Testern (Spitze-Spitze-Werte des Signals)","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 2,048 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 8,448 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 34,648 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 139,264 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 155,520 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,02 UI"},{"name":"相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 622,080 Mb/s","range":"0 UI to 800 UI","cmc":"5 % 测量值 + 0,07 UI"},{"name":"","range":"For phase time fluctuation frequencies 100 Hz, 1 kHz, 10 kHz, 100 kHz ranges and bit rates as above","cmc":"0,002 UI do 0,02 UI"},{"name":"","range":"For phase time fluctuation frequencies 2 Hz to 20 MHz, ranges and bit rates as above","cmc":"(5 % do 19 %) w. mierz 0,024 UI do 0,2 UI"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"PDH/SDH 分析仪/测试仪发射机中的相位时间波动（抖动）发生器（信号峰峰值） 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) 相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 2,048 Mb/s 相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 8,448 Mb/s 相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 34,648 Mb/s 相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 139,264 Mb/s 相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 155,520 Mb/s 相位时间波动频率为 1 kHz（PDH）和 100 kHz（SDH）时; 622,080 Mb/s LMEEiO/30 LMEEiO/27","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"PDH/SDH 分析仪/测试仪发射机中的相位时间波动（抖动）发生器（信号峰峰值）","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 2,048 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 8,448 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 34,648 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 139,264 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,002 UI"},{"name":"Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 155,520 Mb/s","range":"0 UI to 21,751 UI","cmc":"0,02 UI"},{"name":"Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 622,080 Mb/s","range":"0 UI to 800 UI","cmc":"5 % měř. hodnoty + 0,07 UI"},{"name":"","range":"For phase time fluctuation frequencies 100 Hz, 1 kHz, 10 kHz, 100 kHz ranges and bit rates as above","cmc":"0,002 UI do 0,02 UI"},{"name":"","range":"For phase time fluctuation frequencies 2 Hz to 20 MHz, ranges and bit rates as above","cmc":"(5 % do 19 %) w. mierz 0,024 UI do 0,2 UI"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Generátory fluktuace fázového času obsažené ve vysílačích analyzátorů/testerů PDH/SDH (mezivrcholové hodnoty signálu) Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 2,048 Mb/s Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 8,448 Mb/s Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 34,648 Mb/s Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 139,264 Mb/s Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 155,520 Mb/s Pro kmitočty fluktuace fázového času 1 kHz (PDH) a 100 kHz (SDH); 622,080 Mb/s LMEEiO/30 LMEEiO/27","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Generátory fluktuace fázového času obsažené ve vysílačích analyzátorů/testerů PDH/SDH (mezivrcholové hodnoty signálu)"},{"_id":"0c1ff76404fc144fdcc2343c","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory wysokostabilne,\nGeneratory kwarcowe i bezkwarcowe\n(wzorce lub generatory częstotliwości działające w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegów, kalibratory; lub kontrolowane sygnałem radiowym lub sygnałem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnałem telekomunikacyjnym przesyłanym przewodowo)","test_object_en":"High-stability generators,\nQuartz and non-quartz generators\n(frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire)","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"5 · 10⁻¹⁴ · f w czasie uśredniania 7d"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"5 · 10⁻¹³ · f w czasie uśredniania 1 h"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹² · f w czasie uśredniania 1000 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹¹ · f w czasie uśredniania 100 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"7 · 10⁻¹⁴ · f w czasie uśredniania 1d (pod warunkiem jednoczesnych zdalnych porównań z państwowym wzorcem pomiarowym GUM)"}],"parameters_en":[{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"5 · 10⁻¹⁴ · f at averaging time 7d"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"5 · 10⁻¹³ · f at averaging time 1 h"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹² · f at averaging time 1000 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹¹ · f at averaging time 100 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"7 · 10⁻¹⁴ · f at averaging time 1d (provided simultaneous remote comparisons with the national measurement standard of GUM)"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 5 · 10⁻¹⁴ · f w czasie uśredniania 7d\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 5 · 10⁻¹³ · f w czasie uśredniania 1 h\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹² · f w czasie uśredniania 1000 s\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹¹ · f w czasie uśredniania 100 s\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 7 · 10⁻¹⁴ · f w czasie uśredniania 1d (pod warunkiem jednoczesnych zdalnych porównań z państwowym wzorcem pomiarowym GUM)\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44","norm_bases":["LMEEiO/7","LMEEiO/9","LMEEiO/32","LMEEiO/33","LMEEiO/39","LMEEiO/40","LMEEiO/41","LMEEiO/43","LMEEiO/44"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":"f – wielkość mierzona (Hz)","note_en":"f – measured value (Hz)","search_text":"Generatory wysokostabilne,\nGeneratory kwarcowe i bezkwarcowe\n(wzorce lub generatory częstotliwości działające w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegów, kalibratory; lub kontrolowane sygnałem radiowym lub sygnałem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnałem telekomunikacyjnym przesyłanym przewodowo) Wzorcowanie — Częstotliwość\nZakres:\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 5 · 10⁻¹⁴ · f w czasie uśredniania 7d\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 5 · 10⁻¹³ · f w czasie uśredniania 1 h\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹² · f w czasie uśredniania 1000 s\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹¹ · f w czasie uśredniania 100 s\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 7 · 10⁻¹⁴ · f w czasie uśredniania 1d (pod warunkiem jednoczesnych zdalnych porównań z państwowym wzorcem pomiarowym GUM)\nProcedura wewnętrzna; W stałej lokalizacji (S) LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44 Generatory wysokostabilne,\nGeneratory kwarcowe i bezkwarcowe\n(wzorce lub generatory czestotliwosci dzialajace w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegow, kalibratory; lub kontrolowane sygnalem radiowym lub sygnalem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnalem telekomunikacyjnym przesylanym przewodowo) Wzorcowanie — Czestotliwosc\nZakres:\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 5 · 10⁻¹⁴ · f w czasie usredniania 7d\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 5 · 10⁻¹³ · f w czasie usredniania 1 h\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹² · f w czasie usredniania 1000 s\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹¹ · f w czasie usredniania 100 s\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 7 · 10⁻¹⁴ · f w czasie usredniania 1d (pod warunkiem jednoczesnych zdalnych porownan z panstwowym wzorcem pomiarowym GUM)\nProcedura wewnetrzna; W stalej lokalizacji (S) LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44","search_en":"High-stability generators, Quartz and non-quartz generators (frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire) Calibration — Frequency Internal procedure; At permanent location (S) Frequency Internal procedure At permanent location (S) LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":67,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"5 · 10⁻¹⁴ · f bei Mittelungszeit 7d"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"5 · 10⁻¹³ · f bei Mittelungszeit 1 h"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹² · f bei Mittelungszeit 1000 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹¹ · f bei Mittelungszeit 100 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"7 · 10⁻¹⁴ · f bei Mittelungszeit 1d (unter der Bedingung gleichzeitiger Fernvergleiche mit dem nationalen Messnormal des GUM)"}],"regulatory_area_de":"Frequenz","search_de":"Hochstabile Generatoren, Quarz- und quarzlose Generatoren (Frequenznormale oder -generatoren im freilaufenden Betrieb, einschließlich Quarz- und Atomnormale, Generatoren, Arbiträrgeneratoren, Funktionsgeneratoren, Signalformgeneratoren, Kalibratoren; oder gesteuert durch ein Funksignal oder ein Funknavigationssignal eines terrestrischen Systems wie LORAN oder eines Satellitensystems wie GPS oder durch ein leitungsgebundenes Telekommunikationssignal) Kalibrierung — Frequenz Internes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Am festen Standort (S) LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Hochstabile Generatoren,\nQuarz- und quarzlose Generatoren\n(Frequenznormale oder -generatoren im freilaufenden Betrieb, einschließlich Quarz- und Atomnormale, Generatoren, Arbiträrgeneratoren, Funktionsgeneratoren, Signalformgeneratoren, Kalibratoren; oder gesteuert durch ein Funksignal oder ein Funknavigationssignal eines terrestrischen Systems wie LORAN oder eines Satellitensystems wie GPS oder durch ein leitungsgebundenes Telekommunikationssignal)","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"5 · 10⁻¹⁴ · f，平均时间 7d"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"5 · 10⁻¹³ · f，平均时间 1 h"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹² · f，平均时间 1000 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹¹ · f，平均时间 100 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"7 · 10⁻¹⁴ · f，平均时间 1d（前提是同时与 GUM 国家测量标准进行远程比对）"}],"regulatory_area_zh":"频率","search_zh":"高稳定度发生器， 石英与非石英发生器 （自由运行模式下的频率标准或频率发生器，包括石英和原子频标、发生器、任意波形发生器、函数发生器、波形发生器、校准器；或由无线电信号、陆基系统（如 LORAN）或卫星系统（如 GPS）的无线电导航信号，或有线传输的电信信号控制） 校准 — 频率 内部程序；在固定地点 (S) 频率 内部程序 在固定地点 (S) LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"高稳定度发生器，\n石英与非石英发生器\n（自由运行模式下的频率标准或频率发生器，包括石英和原子频标、发生器、任意波形发生器、函数发生器、波形发生器、校准器；或由无线电信号、陆基系统（如 LORAN）或卫星系统（如 GPS）的无线电导航信号，或有线传输的电信信号控制）","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"5 · 10⁻¹⁴ · f při době průměrování 7d"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"5 · 10⁻¹³ · f při době průměrování 1 h"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹² · f při době průměrování 1000 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹¹ · f při době průměrování 100 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"7 · 10⁻¹⁴ · f při době průměrování 1d (za podmínky současných dálkových porovnání se státním etalonem GUM)"}],"regulatory_area_cs":"Frekvence","search_cs":"Vysoce stabilní generátory, Krystalové a nekrystalové generátory (etalony nebo generátory kmitočtu pracující ve volném režimu, včetně křemenných a atomových etalonů, generátorů, libovolných generátorů, funkčních generátorů, generátorů průběhů, kalibrátorů; nebo řízené rádiovým signálem nebo radionavigačním signálem pozemního systému, jako je LORAN, nebo družicového systému, jako je GPS, nebo telekomunikačním signálem přenášeným po vedení) Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) Frekvence Vnitřní postup Ve stálé lokalitě (S) LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Vysoce stabilní generátory,\nKrystalové a nekrystalové generátory\n(etalony nebo generátory kmitočtu pracující ve volném režimu, včetně křemenných a atomových etalonů, generátorů, libovolných generátorů, funkčních generátorů, generátorů průběhů, kalibrátorů; nebo řízené rádiovým signálem nebo radionavigačním signálem pozemního systému, jako je LORAN, nebo družicového systému, jako je GPS, nebo telekomunikačním signálem přenášeným po vedení)"},{"_id":"61b951de857ce0359d5120f7","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory wysokostabilne,\nGeneratory kwarcowe i bezkwarcowe\n(wzorce lub generatory częstotliwości działające w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegów, kalibratory; lub kontrolowane sygnałem radiowym lub sygnałem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnałem telekomunikacyjnym przesyłanym przewodowo)","test_object_en":"High-stability generators,\nQuartz and non-quartz generators\n(frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire)","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f w czasie uśredniania 1d"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f w czasie uśredniania 1 h"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1·10⁻¹⁰ · f w czasie uśredniania 1000 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f w czasie uśredniania 100 s"}],"parameters_en":[{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f at averaging time 1d"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f at averaging time 1 h"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1·10⁻¹⁰ · f at averaging time 1000 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f at averaging time 100 s"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania 1d\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania 1 h\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1·10⁻¹⁰ · f w czasie uśredniania 1000 s\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania 100 s\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44","norm_bases":["LMEEiO/7","LMEEiO/9","LMEEiO/32","LMEEiO/33","LMEEiO/39","LMEEiO/40","LMEEiO/41","LMEEiO/43","LMEEiO/44"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"P","note":"f – wielkość mierzona (Hz)","note_en":"f – measured value (Hz)","search_text":"Generatory wysokostabilne,\nGeneratory kwarcowe i bezkwarcowe\n(wzorce lub generatory częstotliwości działające w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegów, kalibratory; lub kontrolowane sygnałem radiowym lub sygnałem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnałem telekomunikacyjnym przesyłanym przewodowo) Wzorcowanie — Częstotliwość\nZakres:\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania 1d\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania 1 h\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1·10⁻¹⁰ · f w czasie uśredniania 1000 s\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania 100 s\nProcedura wewnętrzna; Poza stałą lokalizacją (P) LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44 Generatory wysokostabilne,\nGeneratory kwarcowe i bezkwarcowe\n(wzorce lub generatory czestotliwosci dzialajace w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegow, kalibratory; lub kontrolowane sygnalem radiowym lub sygnalem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnalem telekomunikacyjnym przesylanym przewodowo) Wzorcowanie — Czestotliwosc\nZakres:\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹⁰ · f w czasie usredniania 1d\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹⁰ · f w czasie usredniania 1 h\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1·10⁻¹⁰ · f w czasie usredniania 1000 s\n100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz CMC 1 · 10⁻¹⁰ · f w czasie usredniania 100 s\nProcedura wewnetrzna; Poza stala lokalizacja (P) LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44","search_en":"High-stability generators, Quartz and non-quartz generators (frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire) Calibration — Frequency Internal procedure; Outside of permanent location (P) Frequency Internal procedure Outside of permanent location (P) LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":68,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f bei Mittelungszeit 1d"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f bei Mittelungszeit 1 h"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1·10⁻¹⁰ · f bei Mittelungszeit 1000 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f bei Mittelungszeit 100 s"}],"regulatory_area_de":"Frequenz","search_de":"Hochstabile Generatoren, Quarz- und quarzlose Generatoren (Frequenznormale oder -generatoren im freilaufenden Betrieb, einschließlich Quarz- und Atomnormale, Generatoren, Arbiträrgeneratoren, Funktionsgeneratoren, Signalformgeneratoren, Kalibratoren; oder gesteuert durch ein Funksignal oder ein Funknavigationssignal eines terrestrischen Systems wie LORAN oder eines Satellitensystems wie GPS oder durch ein leitungsgebundenes Telekommunikationssignal) Kalibrierung — Frequenz Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Frequenz Internes Verfahren Außerhalb des festen Standorts (P) LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Hochstabile Generatoren,\nQuarz- und quarzlose Generatoren\n(Frequenznormale oder -generatoren im freilaufenden Betrieb, einschließlich Quarz- und Atomnormale, Generatoren, Arbiträrgeneratoren, Funktionsgeneratoren, Signalformgeneratoren, Kalibratoren; oder gesteuert durch ein Funksignal oder ein Funknavigationssignal eines terrestrischen Systems wie LORAN oder eines Satellitensystems wie GPS oder durch ein leitungsgebundenes Telekommunikationssignal)","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f，平均时间 1d"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f，平均时间 1 h"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1·10⁻¹⁰ · f，平均时间 1000 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f，平均时间 100 s"}],"regulatory_area_zh":"频率","search_zh":"高稳定度发生器， 石英与非石英发生器 （自由运行模式下的频率标准或频率发生器，包括石英和原子频标、发生器、任意波形发生器、函数发生器、波形发生器、校准器；或由无线电信号、陆基系统（如 LORAN）或卫星系统（如 GPS）的无线电导航信号，或有线传输的电信信号控制） 校准 — 频率 内部程序；固定地点以外 (P) 频率 内部程序 固定地点以外 (P) LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"高稳定度发生器，\n石英与非石英发生器\n（自由运行模式下的频率标准或频率发生器，包括石英和原子频标、发生器、任意波形发生器、函数发生器、波形发生器、校准器；或由无线电信号、陆基系统（如 LORAN）或卫星系统（如 GPS）的无线电导航信号，或有线传输的电信信号控制）","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f při době průměrování 1d"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f při době průměrování 1 h"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1·10⁻¹⁰ · f při době průměrování 1000 s"},{"name":"","range":"100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","cmc":"1 · 10⁻¹⁰ · f při době průměrování 100 s"}],"regulatory_area_cs":"Frekvence","search_cs":"Vysoce stabilní generátory, Krystalové a nekrystalové generátory (etalony nebo generátory kmitočtu pracující ve volném režimu, včetně křemenných a atomových etalonů, generátorů, libovolných generátorů, funkčních generátorů, generátorů průběhů, kalibrátorů; nebo řízené rádiovým signálem nebo radionavigačním signálem pozemního systému, jako je LORAN, nebo družicového systému, jako je GPS, nebo telekomunikačním signálem přenášeným po vedení) Kalibrace — Kmitočet Vnitřní postup; Mimo stálé pracoviště (P) Frekvence Vnitřní postup Mimo stálou lokalitu (P) LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Vysoce stabilní generátory,\nKrystalové a nekrystalové generátory\n(etalony nebo generátory kmitočtu pracující ve volném režimu, včetně křemenných a atomových etalonů, generátorů, libovolných generátorů, funkčních generátorů, generátorů průběhů, kalibrátorů; nebo řízené rádiovým signálem nebo radionavigačním signálem pozemního systému, jako je LORAN, nebo družicového systému, jako je GPS, nebo telekomunikačním signálem přenášeným po vedení)"},{"_id":"60967ca9c356860b7711eeea","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory wysokostabilne,\nGeneratorykwarcowe i bezkwarcowe\n(wzorce lub generatory częstotliwości działające w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegów, kalibratory; lub kontrolowane sygnałem radiowym lub sygnałem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnałem telekomunikacyjnym przesyłanym przewodowo)","test_object_en":"High-stability generators,\nQuartz and non-quartz generators\n(frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire)","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"sygnał prostokątny (w zakresie 0,001 Hz do 0,1 Hz pomiary okresu)","range":"0,001 Hz do 3 GHz","cmc":"1 · 10⁻¹¹ · f w czasie uśredniania ≥ 1 s"},{"name":"sygnał sinusoidalny","range":"10 kHz do 40 GHz","cmc":"1 · 10⁻¹¹ · f w czasie uśredniania ≥ 1 s"}],"parameters_en":[{"name":"square wave signal (period measurements in the range 0,001 Hz to 0,1 Hz)","range":"0,001 Hz to 3 GHz","cmc":"1 · 10⁻¹¹ · f at averaging time ≥ 1 s"},{"name":"sinusoidal signal","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹¹ · f at averaging time ≥ 1 s"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\nsygnał prostokątny (w zakresie 0,001 Hz do 0,1 Hz pomiary okresu) 0,001 Hz do 3 GHz CMC 1 · 10⁻¹¹ · f w czasie uśredniania ≥ 1 s\nsygnał sinusoidalny 10 kHz do 40 GHz CMC 1 · 10⁻¹¹ · f w czasie uśredniania ≥ 1 s\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44","norm_bases":["LMEEiO/7","LMEEiO/9","LMEEiO/32","LMEEiO/33","LMEEiO/39","LMEEiO/40","LMEEiO/41","LMEEiO/43","LMEEiO/44"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":"f – wielkość mierzona (Hz)","note_en":"f – measured value (Hz)","search_text":"Generatory wysokostabilne,\nGeneratorykwarcowe i bezkwarcowe\n(wzorce lub generatory częstotliwości działające w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegów, kalibratory; lub kontrolowane sygnałem radiowym lub sygnałem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnałem telekomunikacyjnym przesyłanym przewodowo) Wzorcowanie — Częstotliwość\nZakres:\nsygnał prostokątny (w zakresie 0,001 Hz do 0,1 Hz pomiary okresu) 0,001 Hz do 3 GHz CMC 1 · 10⁻¹¹ · f w czasie uśredniania ≥ 1 s\nsygnał sinusoidalny 10 kHz do 40 GHz CMC 1 · 10⁻¹¹ · f w czasie uśredniania ≥ 1 s\nProcedura wewnętrzna; W stałej lokalizacji (S) LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44 Generatory wysokostabilne,\nGeneratorykwarcowe i bezkwarcowe\n(wzorce lub generatory czestotliwosci dzialajace w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegow, kalibratory; lub kontrolowane sygnalem radiowym lub sygnalem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnalem telekomunikacyjnym przesylanym przewodowo) Wzorcowanie — Czestotliwosc\nZakres:\nsygnal prostokatny (w zakresie 0,001 Hz do 0,1 Hz pomiary okresu) 0,001 Hz do 3 GHz CMC 1 · 10⁻¹¹ · f w czasie usredniania ≥ 1 s\nsygnal sinusoidalny 10 kHz do 40 GHz CMC 1 · 10⁻¹¹ · f w czasie usredniania ≥ 1 s\nProcedura wewnetrzna; W stalej lokalizacji (S) LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44","search_en":"High-stability generators, Quartz and non-quartz generators (frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire) Calibration — Frequency Internal procedure; At permanent location (S) Frequency Internal procedure At permanent location (S) square wave signal (period measurements in the range 0,001 Hz to 0,1 Hz) sinusoidal signal LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":69,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"Rechtecksignal (im Bereich 0,001 Hz bis 0,1 Hz Periodenmessungen)","range":"0,001 Hz to 3 GHz","cmc":"1 · 10⁻¹¹ · f bei Mittelungszeit ≥ 1 s"},{"name":"Sinussignal","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹¹ · f bei Mittelungszeit ≥ 1 s"}],"regulatory_area_de":"Frequenz","search_de":"Hochstabile Generatoren, Quarz- und quarzlose Generatoren (Frequenznormale oder -generatoren im freilaufenden Betrieb, einschließlich Quarz- und Atomnormale, Generatoren, Arbiträrgeneratoren, Funktionsgeneratoren, Signalformgeneratoren, Kalibratoren; oder gesteuert durch ein Funksignal oder ein Funknavigationssignal eines terrestrischen Systems wie LORAN oder eines Satellitensystems wie GPS oder durch ein leitungsgebundenes Telekommunikationssignal) Kalibrierung — Frequenz Internes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Am festen Standort (S) Rechtecksignal (im Bereich 0,001 Hz bis 0,1 Hz Periodenmessungen) Sinussignal LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Hochstabile Generatoren,\nQuarz- und quarzlose Generatoren\n(Frequenznormale oder -generatoren im freilaufenden Betrieb, einschließlich Quarz- und Atomnormale, Generatoren, Arbiträrgeneratoren, Funktionsgeneratoren, Signalformgeneratoren, Kalibratoren; oder gesteuert durch ein Funksignal oder ein Funknavigationssignal eines terrestrischen Systems wie LORAN oder eines Satellitensystems wie GPS oder durch ein leitungsgebundenes Telekommunikationssignal)","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"方波信号（0,001 Hz 至 0,1 Hz 范围内为周期测量）","range":"0,001 Hz to 3 GHz","cmc":"1 · 10⁻¹¹ · f，平均时间 ≥ 1 s"},{"name":"正弦信号","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹¹ · f，平均时间 ≥ 1 s"}],"regulatory_area_zh":"频率","search_zh":"高稳定度发生器， 石英与非石英发生器 （自由运行模式下的频率标准或频率发生器，包括石英和原子频标、发生器、任意波形发生器、函数发生器、波形发生器、校准器；或由无线电信号、陆基系统（如 LORAN）或卫星系统（如 GPS）的无线电导航信号，或有线传输的电信信号控制） 校准 — 频率 内部程序；在固定地点 (S) 频率 内部程序 在固定地点 (S) 方波信号（0,001 Hz 至 0,1 Hz 范围内为周期测量） 正弦信号 LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"高稳定度发生器，\n石英与非石英发生器\n（自由运行模式下的频率标准或频率发生器，包括石英和原子频标、发生器、任意波形发生器、函数发生器、波形发生器、校准器；或由无线电信号、陆基系统（如 LORAN）或卫星系统（如 GPS）的无线电导航信号，或有线传输的电信信号控制）","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"obdélníkový signál (v rozsahu 0,001 Hz až 0,1 Hz měření periody)","range":"0,001 Hz to 3 GHz","cmc":"1 · 10⁻¹¹ · f při době průměrování ≥ 1 s"},{"name":"sinusový signál","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹¹ · f při době průměrování ≥ 1 s"}],"regulatory_area_cs":"Frekvence","search_cs":"Vysoce stabilní generátory, Krystalové a nekrystalové generátory (etalony nebo generátory kmitočtu pracující ve volném režimu, včetně křemenných a atomových etalonů, generátorů, libovolných generátorů, funkčních generátorů, generátorů průběhů, kalibrátorů; nebo řízené rádiovým signálem nebo radionavigačním signálem pozemního systému, jako je LORAN, nebo družicového systému, jako je GPS, nebo telekomunikačním signálem přenášeným po vedení) Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) Frekvence Vnitřní postup Ve stálé lokalitě (S) obdélníkový signál (v rozsahu 0,001 Hz až 0,1 Hz měření periody) sinusový signál LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Vysoce stabilní generátory,\nKrystalové a nekrystalové generátory\n(etalony nebo generátory kmitočtu pracující ve volném režimu, včetně křemenných a atomových etalonů, generátorů, libovolných generátorů, funkčních generátorů, generátorů průběhů, kalibrátorů; nebo řízené rádiovým signálem nebo radionavigačním signálem pozemního systému, jako je LORAN, nebo družicového systému, jako je GPS, nebo telekomunikačním signálem přenášeným po vedení)"},{"_id":"f675ce55e10cfac672f974f4","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory wysokostabilne,\nGeneratorykwarcowe i bezkwarcowe\n(wzorce lub generatory częstotliwości działające w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegów, kalibratory; lub kontrolowane sygnałem radiowym lub sygnałem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnałem telekomunikacyjnym przesyłanym przewodowo)","test_object_en":"High-stability generators,\nQuartz and non-quartz generators\n(frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire)","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"sygnał prostokątny (w zakresie 0,001 Hz do 0,1 Hz pomiary okresu)","range":"0,001 Hz do 3 GHz","cmc":"1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s"},{"name":"sygnał sinusoidalny","range":"10 kHz do 40 GHz","cmc":"1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s"}],"parameters_en":[{"name":"square wave signal (period measurements in the range 0,001 Hz to 0,1 Hz)","range":"0,001 Hz to 3 GHz","cmc":"1 · 10⁻¹⁰ · f at averaging time ≥ 1 s"},{"name":"sinusoidal signal","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹⁰ · f at averaging time ≥ 1 s"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\nsygnał prostokątny (w zakresie 0,001 Hz do 0,1 Hz pomiary okresu) 0,001 Hz do 3 GHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s\nsygnał sinusoidalny 10 kHz do 40 GHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44","norm_bases":["LMEEiO/7","LMEEiO/9","LMEEiO/32","LMEEiO/33","LMEEiO/39","LMEEiO/40","LMEEiO/41","LMEEiO/43","LMEEiO/44"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"P","note":"f – wielkość mierzona (Hz)","note_en":"f – measured value (Hz)","search_text":"Generatory wysokostabilne,\nGeneratorykwarcowe i bezkwarcowe\n(wzorce lub generatory częstotliwości działające w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegów, kalibratory; lub kontrolowane sygnałem radiowym lub sygnałem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnałem telekomunikacyjnym przesyłanym przewodowo) Wzorcowanie — Częstotliwość\nZakres:\nsygnał prostokątny (w zakresie 0,001 Hz do 0,1 Hz pomiary okresu) 0,001 Hz do 3 GHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s\nsygnał sinusoidalny 10 kHz do 40 GHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s\nProcedura wewnętrzna; Poza stałą lokalizacją (P) LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44 Generatory wysokostabilne,\nGeneratorykwarcowe i bezkwarcowe\n(wzorce lub generatory czestotliwosci dzialajace w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegow, kalibratory; lub kontrolowane sygnalem radiowym lub sygnalem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnalem telekomunikacyjnym przesylanym przewodowo) Wzorcowanie — Czestotliwosc\nZakres:\nsygnal prostokatny (w zakresie 0,001 Hz do 0,1 Hz pomiary okresu) 0,001 Hz do 3 GHz CMC 1 · 10⁻¹⁰ · f w czasie usredniania ≥ 1 s\nsygnal sinusoidalny 10 kHz do 40 GHz CMC 1 · 10⁻¹⁰ · f w czasie usredniania ≥ 1 s\nProcedura wewnetrzna; Poza stala lokalizacja (P) LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44","search_en":"High-stability generators, Quartz and non-quartz generators (frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire) Calibration — Frequency Internal procedure; Outside of permanent location (P) Frequency Internal procedure Outside of permanent location (P) square wave signal (period measurements in the range 0,001 Hz to 0,1 Hz) sinusoidal signal LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":70,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"Rechtecksignal (im Bereich 0,001 Hz bis 0,1 Hz Periodenmessungen)","range":"0,001 Hz to 3 GHz","cmc":"1 · 10⁻¹⁰ · f bei Mittelungszeit ≥ 1 s"},{"name":"Sinussignal","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹⁰ · f bei Mittelungszeit ≥ 1 s"}],"regulatory_area_de":"Frequenz","search_de":"Hochstabile Generatoren, Quarz- und quarzlose Generatoren (Frequenznormale oder -generatoren im freilaufenden Betrieb, einschließlich Quarz- und Atomnormale, Generatoren, Arbiträrgeneratoren, Funktionsgeneratoren, Signalformgeneratoren, Kalibratoren; oder gesteuert durch ein Funksignal oder ein Funknavigationssignal eines terrestrischen Systems wie LORAN oder eines Satellitensystems wie GPS oder durch ein leitungsgebundenes Telekommunikationssignal) Kalibrierung — Frequenz Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Frequenz Internes Verfahren Außerhalb des festen Standorts (P) Rechtecksignal (im Bereich 0,001 Hz bis 0,1 Hz Periodenmessungen) Sinussignal LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Hochstabile Generatoren,\nQuarz- und quarzlose Generatoren\n(Frequenznormale oder -generatoren im freilaufenden Betrieb, einschließlich Quarz- und Atomnormale, Generatoren, Arbiträrgeneratoren, Funktionsgeneratoren, Signalformgeneratoren, Kalibratoren; oder gesteuert durch ein Funksignal oder ein Funknavigationssignal eines terrestrischen Systems wie LORAN oder eines Satellitensystems wie GPS oder durch ein leitungsgebundenes Telekommunikationssignal)","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"方波信号（0,001 Hz 至 0,1 Hz 范围内为周期测量）","range":"0,001 Hz to 3 GHz","cmc":"1 · 10⁻¹⁰ · f，平均时间 ≥ 1 s"},{"name":"正弦信号","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹⁰ · f，平均时间 ≥ 1 s"}],"regulatory_area_zh":"频率","search_zh":"高稳定度发生器， 石英与非石英发生器 （自由运行模式下的频率标准或频率发生器，包括石英和原子频标、发生器、任意波形发生器、函数发生器、波形发生器、校准器；或由无线电信号、陆基系统（如 LORAN）或卫星系统（如 GPS）的无线电导航信号，或有线传输的电信信号控制） 校准 — 频率 内部程序；固定地点以外 (P) 频率 内部程序 固定地点以外 (P) 方波信号（0,001 Hz 至 0,1 Hz 范围内为周期测量） 正弦信号 LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"高稳定度发生器，\n石英与非石英发生器\n（自由运行模式下的频率标准或频率发生器，包括石英和原子频标、发生器、任意波形发生器、函数发生器、波形发生器、校准器；或由无线电信号、陆基系统（如 LORAN）或卫星系统（如 GPS）的无线电导航信号，或有线传输的电信信号控制）","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"obdélníkový signál (v rozsahu 0,001 Hz až 0,1 Hz měření periody)","range":"0,001 Hz to 3 GHz","cmc":"1 · 10⁻¹⁰ · f při době průměrování ≥ 1 s"},{"name":"sinusový signál","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹⁰ · f při době průměrování ≥ 1 s"}],"regulatory_area_cs":"Frekvence","search_cs":"Vysoce stabilní generátory, Krystalové a nekrystalové generátory (etalony nebo generátory kmitočtu pracující ve volném režimu, včetně křemenných a atomových etalonů, generátorů, libovolných generátorů, funkčních generátorů, generátorů průběhů, kalibrátorů; nebo řízené rádiovým signálem nebo radionavigačním signálem pozemního systému, jako je LORAN, nebo družicového systému, jako je GPS, nebo telekomunikačním signálem přenášeným po vedení) Kalibrace — Kmitočet Vnitřní postup; Mimo stálé pracoviště (P) Frekvence Vnitřní postup Mimo stálou lokalitu (P) obdélníkový signál (v rozsahu 0,001 Hz až 0,1 Hz měření periody) sinusový signál LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Vysoce stabilní generátory,\nKrystalové a nekrystalové generátory\n(etalony nebo generátory kmitočtu pracující ve volném režimu, včetně křemenných a atomových etalonů, generátorů, libovolných generátorů, funkčních generátorů, generátorů průběhů, kalibrátorů; nebo řízené rádiovým signálem nebo radionavigačním signálem pozemního systému, jako je LORAN, nebo družicového systému, jako je GPS, nebo telekomunikačním signálem přenášeným po vedení)"},{"_id":"c860541ea09078fb1ef426f8","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Generatory wysokostabilne,\nGeneratorykwarcowe i bezkwarcowe\n(wzorce lub generatory częstotliwości działające w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegów, kalibratory; lub kontrolowane sygnałem radiowym lub sygnałem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnałem telekomunikacyjnym przesyłanym przewodowo)","test_object_en":"High-stability generators,\nQuartz and non-quartz generators\n(frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire)","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"1 kHz do 10 kHz","cmc":"1 · 10⁻¹⁰ · f"},{"name":"","range":"100 Hz do 1 kHz","cmc":"1 · 10⁻⁹ · f"},{"name":"","range":"1 Hz do 100 Hz","cmc":"5 · 10⁻⁸ · f"},{"name":"","range":"0,1 Hz do 1 Hz","cmc":"1 · 10⁻⁷ · f"}],"parameters_en":[{"name":"","range":"1 kHz to 10 kHz","cmc":"1 · 10⁻¹⁰ · f"},{"name":"","range":"100 Hz to 1 kHz","cmc":"1 · 10⁻⁹ · f"},{"name":"","range":"1 Hz to 100 Hz","cmc":"5 · 10⁻⁸ · f"},{"name":"","range":"0,1 Hz to 1 Hz","cmc":"1 · 10⁻⁷ · f"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\n1 kHz do 10 kHz CMC 1 · 10⁻¹⁰ · f\n100 Hz do 1 kHz CMC 1 · 10⁻⁹ · f\n1 Hz do 100 Hz CMC 5 · 10⁻⁸ · f\n0,1 Hz do 1 Hz CMC 1 · 10⁻⁷ · f\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44","norm_bases":["LMEEiO/7","LMEEiO/9","LMEEiO/32","LMEEiO/33","LMEEiO/39","LMEEiO/40","LMEEiO/41","LMEEiO/43","LMEEiO/44"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"S, P","note":"f – wielkość mierzona (Hz)","note_en":"f – measured value (Hz)","search_text":"Generatory wysokostabilne,\nGeneratorykwarcowe i bezkwarcowe\n(wzorce lub generatory częstotliwości działające w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegów, kalibratory; lub kontrolowane sygnałem radiowym lub sygnałem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnałem telekomunikacyjnym przesyłanym przewodowo) Wzorcowanie — Częstotliwość\nZakres:\n1 kHz do 10 kHz CMC 1 · 10⁻¹⁰ · f\n100 Hz do 1 kHz CMC 1 · 10⁻⁹ · f\n1 Hz do 100 Hz CMC 5 · 10⁻⁸ · f\n0,1 Hz do 1 Hz CMC 1 · 10⁻⁷ · f\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44 Generatory wysokostabilne,\nGeneratorykwarcowe i bezkwarcowe\n(wzorce lub generatory czestotliwosci dzialajace w trybie swobodnym w tym wzorce kwarcowe, atomowe, generatory, generatory arbitralne, generatory funkcyjne, generatory przebiegow, kalibratory; lub kontrolowane sygnalem radiowym lub sygnalem radionawigacyjnym systemu naziemnego, jak LORAN lub satelitarnego, jak GPS lub sygnalem telekomunikacyjnym przesylanym przewodowo) Wzorcowanie — Czestotliwosc\nZakres:\n1 kHz do 10 kHz CMC 1 · 10⁻¹⁰ · f\n100 Hz do 1 kHz CMC 1 · 10⁻⁹ · f\n1 Hz do 100 Hz CMC 5 · 10⁻⁸ · f\n0,1 Hz do 1 Hz CMC 1 · 10⁻⁷ · f\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/7\nLMEEiO/9\nLMEEiO/32\nLMEEiO/33\nLMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44","search_en":"High-stability generators, Quartz and non-quartz generators (frequency standards or generators operating in free-running mode, including quartz and atomic standards, generators, arbitrary generators, function generators, waveform generators, calibrators; or controlled by a radio signal or by a radio navigation signal of a terrestrial system such as LORAN or a satellite system such as GPS, or by a telecommunication signal transmitted by wire) Calibration — Frequency Internal procedure; At permanent location (S) and outside of it (P) Frequency Internal procedure At permanent location (S) and outside of it (P) LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":71,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"1 kHz bis 10 kHz","cmc":"1 · 10⁻¹⁰ · f"},{"name":"","range":"100 Hz bis 1 kHz","cmc":"1 · 10⁻⁹ · f"},{"name":"","range":"1 Hz to 100 Hz","cmc":"5 · 10⁻⁸ · f"},{"name":"","range":"0,1 Hz bis 1 Hz","cmc":"1 · 10⁻⁷ · f"}],"regulatory_area_de":"Frequenz","search_de":"Hochstabile Generatoren, Quarz- und quarzlose Generatoren (Frequenznormale oder -generatoren im freilaufenden Betrieb, einschließlich Quarz- und Atomnormale, Generatoren, Arbiträrgeneratoren, Funktionsgeneratoren, Signalformgeneratoren, Kalibratoren; oder gesteuert durch ein Funksignal oder ein Funknavigationssignal eines terrestrischen Systems wie LORAN oder eines Satellitensystems wie GPS oder durch ein leitungsgebundenes Telekommunikationssignal) Kalibrierung — Frequenz Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Frequenz Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Hochstabile Generatoren,\nQuarz- und quarzlose Generatoren\n(Frequenznormale oder -generatoren im freilaufenden Betrieb, einschließlich Quarz- und Atomnormale, Generatoren, Arbiträrgeneratoren, Funktionsgeneratoren, Signalformgeneratoren, Kalibratoren; oder gesteuert durch ein Funksignal oder ein Funknavigationssignal eines terrestrischen Systems wie LORAN oder eines Satellitensystems wie GPS oder durch ein leitungsgebundenes Telekommunikationssignal)","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"1 kHz 至 10 kHz","cmc":"1 · 10⁻¹⁰ · f"},{"name":"","range":"100 Hz 至 1 kHz","cmc":"1 · 10⁻⁹ · f"},{"name":"","range":"1 Hz to 100 Hz","cmc":"5 · 10⁻⁸ · f"},{"name":"","range":"0,1 Hz to 1 Hz","cmc":"1 · 10⁻⁷ · f"}],"regulatory_area_zh":"频率","search_zh":"高稳定度发生器， 石英与非石英发生器 （自由运行模式下的频率标准或频率发生器，包括石英和原子频标、发生器、任意波形发生器、函数发生器、波形发生器、校准器；或由无线电信号、陆基系统（如 LORAN）或卫星系统（如 GPS）的无线电导航信号，或有线传输的电信信号控制） 校准 — 频率 内部程序；在固定地点 (S) 及固定地点以外 (P) 频率 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"高稳定度发生器，\n石英与非石英发生器\n（自由运行模式下的频率标准或频率发生器，包括石英和原子频标、发生器、任意波形发生器、函数发生器、波形发生器、校准器；或由无线电信号、陆基系统（如 LORAN）或卫星系统（如 GPS）的无线电导航信号，或有线传输的电信信号控制）","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"1 kHz až 10 kHz","cmc":"1 · 10⁻¹⁰ · f"},{"name":"","range":"100 Hz až 1 kHz","cmc":"1 · 10⁻⁹ · f"},{"name":"","range":"1 Hz to 100 Hz","cmc":"5 · 10⁻⁸ · f"},{"name":"","range":"0,1 Hz to 1 Hz","cmc":"1 · 10⁻⁷ · f"}],"regulatory_area_cs":"Frekvence","search_cs":"Vysoce stabilní generátory, Krystalové a nekrystalové generátory (etalony nebo generátory kmitočtu pracující ve volném režimu, včetně křemenných a atomových etalonů, generátorů, libovolných generátorů, funkčních generátorů, generátorů průběhů, kalibrátorů; nebo řízené rádiovým signálem nebo radionavigačním signálem pozemního systému, jako je LORAN, nebo družicového systému, jako je GPS, nebo telekomunikačním signálem přenášeným po vedení) Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Frekvence Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/7 LMEEiO/9 LMEEiO/32 LMEEiO/33 LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Vysoce stabilní generátory,\nKrystalové a nekrystalové generátory\n(etalony nebo generátory kmitočtu pracující ve volném režimu, včetně křemenných a atomových etalonů, generátorů, libovolných generátorů, funkčních generátorů, generátorů průběhů, kalibrátorů; nebo řízené rádiovým signálem nebo radionavigačním signálem pozemního systému, jako je LORAN, nebo družicového systému, jako je GPS, nebo telekomunikačním signálem přenášeným po vedení)"},{"_id":"3bd25fe5801d19e9761d4319","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Nadajniki zawarte w analizatorach transmisji cyfrowej","test_object_en":"Transmitters included in digital transmission analysers","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"8 kHz do 3 GHz","cmc":"1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s"}],"parameters_en":[{"name":"","range":"8 kHz to 3 GHz","cmc":"1 · 10⁻¹⁰ · f at averaging time ≥ 1 s"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n8 kHz do 3 GHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/7\nLMEEiO/27","norm_bases":["LMEEiO/7","LMEEiO/27"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":"f – wielkość mierzona (Hz)","note_en":"f – measured value (Hz)","search_text":"Nadajniki zawarte w analizatorach transmisji cyfrowej Wzorcowanie — Częstotliwość\n8 kHz do 3 GHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/7\nLMEEiO/27 Nadajniki zawarte w analizatorach transmisji cyfrowej Wzorcowanie — Czestotliwosc\n8 kHz do 3 GHz CMC 1 · 10⁻¹⁰ · f w czasie usredniania ≥ 1 s\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/7\nLMEEiO/27","search_en":"Transmitters included in digital transmission analysers Calibration — Frequency Internal procedure; Direct method; At permanent location (S) Frequency Internal procedure Direct method At permanent location (S) LMEEiO/7 LMEEiO/27","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":72,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"8 kHz to 3 GHz","cmc":"1 · 10⁻¹⁰ · f bei Mittelungszeit ≥ 1 s"}],"regulatory_area_de":"Frequenz","search_de":"Sender in Analysatoren für digitale Übertragung Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) LMEEiO/7 LMEEiO/27","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Sender in Analysatoren für digitale Übertragung","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"8 kHz to 3 GHz","cmc":"1 · 10⁻¹⁰ · f，平均时间 ≥ 1 s"}],"regulatory_area_zh":"频率","search_zh":"数字传输分析仪中的发射机 校准 — 频率 内部程序；直接法；在固定地点 (S) 频率 内部程序 直接法 在固定地点 (S) LMEEiO/7 LMEEiO/27","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"数字传输分析仪中的发射机","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"8 kHz to 3 GHz","cmc":"1 · 10⁻¹⁰ · f při době průměrování ≥ 1 s"}],"regulatory_area_cs":"Frekvence","search_cs":"Vysílače obsažené v analyzátorech digitálního přenosu Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Frekvence Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LMEEiO/7 LMEEiO/27","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Vysílače obsažené v analyzátorech digitálního přenosu"},{"_id":"3bf8da79d95af7c5dc6fb57e","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki częstotliwości cyfrowe (w tym mierniki częstotliwości wbudowane np. w mierniki mocy)","test_object_en":"Digital frequency meters (including frequency meters built into e.g. power meters)","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"sygnał prostokątny","range":"0,001 Hz do 100 MHz","cmc":"3 · 10⁻¹⁰ · f w czasie uśredniania ≥ 0,1 s"},{"name":"sygnał sinusoidalny","range":"10 kHz do 40 GHz","cmc":"3 · 10⁻¹⁰ · f w czasie uśredniania ≥ 0,1 s"},{"name":"sygnał sinusoidalny","range":"1 kHz do 10 kHz","cmc":"1 · 10⁻¹⁰ · f"},{"name":"sygnał sinusoidalny","range":"100 Hz do 1 kHz","cmc":"1 · 10⁻⁹ · f"},{"name":"sygnał sinusoidalny","range":"1 Hz do 100 Hz","cmc":"5 · 10⁻⁸ · f"},{"name":"sygnał sinusoidalny","range":"0,1 Hz do 1 Hz","cmc":"1 · 10⁻⁷ · f"}],"parameters_en":[{"name":"square wave signal","range":"0,001 Hz to 100 MHz","cmc":"3 · 10⁻¹⁰ · f at averaging time ≥ 0,1 s"},{"name":"sinusoidal signal","range":"10 kHz to 40 GHz","cmc":"3 · 10⁻¹⁰ · f at averaging time ≥ 0,1 s"},{"name":"sinusoidal signal","range":"1 kHz to 10 kHz","cmc":"1 · 10⁻¹⁰ · f"},{"name":"sinusoidal signal","range":"100 Hz to 1 kHz","cmc":"1 · 10⁻⁹ · f"},{"name":"sinusoidal signal","range":"1 Hz to 100 Hz","cmc":"5 · 10⁻⁸ · f"},{"name":"sinusoidal signal","range":"0,1 Hz to 1 Hz","cmc":"1 · 10⁻⁷ · f"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\nsygnał prostokątny 0,001 Hz do 100 MHz CMC 3 · 10⁻¹⁰ · f w czasie uśredniania ≥ 0,1 s\nsygnał sinusoidalny 10 kHz do 40 GHz CMC 3 · 10⁻¹⁰ · f w czasie uśredniania ≥ 0,1 s\nsygnał sinusoidalny 1 kHz do 10 kHz CMC 1 · 10⁻¹⁰ · f\nsygnał sinusoidalny 100 Hz do 1 kHz CMC 1 · 10⁻⁹ · f\nsygnał sinusoidalny 1 Hz do 100 Hz CMC 5 · 10⁻⁸ · f\nsygnał sinusoidalny 0,1 Hz do 1 Hz CMC 1 · 10⁻⁷ · f\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/16\nLMEEiO/31","norm_bases":["LMEEiO/16","LMEEiO/31"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"S, P","note":"f – wielkość mierzona (Hz). Czas uśredniania nie mniejszy niż okres sygnału, ale w zakresie 1 Hz ÷10 Hz liczba uśrednianych okresów nie mniejsza niż 10","note_en":"f – measured value (Hz). Averaging time not shorter than the signal period, but in the range 1 Hz ÷10 Hz the number of averaged periods not less than 10","search_text":"Mierniki częstotliwości cyfrowe (w tym mierniki częstotliwości wbudowane np. w mierniki mocy) Wzorcowanie — Częstotliwość\nZakres:\nsygnał prostokątny 0,001 Hz do 100 MHz CMC 3 · 10⁻¹⁰ · f w czasie uśredniania ≥ 0,1 s\nsygnał sinusoidalny 10 kHz do 40 GHz CMC 3 · 10⁻¹⁰ · f w czasie uśredniania ≥ 0,1 s\nsygnał sinusoidalny 1 kHz do 10 kHz CMC 1 · 10⁻¹⁰ · f\nsygnał sinusoidalny 100 Hz do 1 kHz CMC 1 · 10⁻⁹ · f\nsygnał sinusoidalny 1 Hz do 100 Hz CMC 5 · 10⁻⁸ · f\nsygnał sinusoidalny 0,1 Hz do 1 Hz CMC 1 · 10⁻⁷ · f\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/16\nLMEEiO/31 Mierniki czestotliwosci cyfrowe (w tym mierniki czestotliwosci wbudowane np. w mierniki mocy) Wzorcowanie — Czestotliwosc\nZakres:\nsygnal prostokatny 0,001 Hz do 100 MHz CMC 3 · 10⁻¹⁰ · f w czasie usredniania ≥ 0,1 s\nsygnal sinusoidalny 10 kHz do 40 GHz CMC 3 · 10⁻¹⁰ · f w czasie usredniania ≥ 0,1 s\nsygnal sinusoidalny 1 kHz do 10 kHz CMC 1 · 10⁻¹⁰ · f\nsygnal sinusoidalny 100 Hz do 1 kHz CMC 1 · 10⁻⁹ · f\nsygnal sinusoidalny 1 Hz do 100 Hz CMC 5 · 10⁻⁸ · f\nsygnal sinusoidalny 0,1 Hz do 1 Hz CMC 1 · 10⁻⁷ · f\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/16\nLMEEiO/31","search_en":"Digital frequency meters (including frequency meters built into e.g. power meters) Calibration — Frequency Internal procedure; At permanent location (S) and outside of it (P) Frequency Internal procedure At permanent location (S) and outside of it (P) square wave signal sinusoidal signal sinusoidal signal sinusoidal signal sinusoidal signal sinusoidal signal LMEEiO/16 LMEEiO/31","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":73,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"Rechtecksignal","range":"0,001 Hz to 100 MHz","cmc":"3 · 10⁻¹⁰ · f bei Mittelungszeit ≥ 0,1 s"},{"name":"Sinussignal","range":"10 kHz to 40 GHz","cmc":"3 · 10⁻¹⁰ · f bei Mittelungszeit ≥ 0,1 s"},{"name":"Sinussignal","range":"1 kHz bis 10 kHz","cmc":"1 · 10⁻¹⁰ · f"},{"name":"Sinussignal","range":"100 Hz bis 1 kHz","cmc":"1 · 10⁻⁹ · f"},{"name":"Sinussignal","range":"1 Hz to 100 Hz","cmc":"5 · 10⁻⁸ · f"},{"name":"Sinussignal","range":"0,1 Hz bis 1 Hz","cmc":"1 · 10⁻⁷ · f"}],"regulatory_area_de":"Frequenz","search_de":"Digitale Frequenzmesser (einschließlich z. B. in Leistungsmesser eingebauter Frequenzmesser) Kalibrierung — Frequenz Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Frequenz Internes Verfahren Am festen Standort (S) und außerhalb (P) Rechtecksignal Sinussignal Sinussignal Sinussignal Sinussignal Sinussignal LMEEiO/16 LMEEiO/31","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Digitale Frequenzmesser (einschließlich z. B. in Leistungsmesser eingebauter Frequenzmesser)","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"方波信号","range":"0,001 Hz to 100 MHz","cmc":"3 · 10⁻¹⁰ · f，平均时间 ≥ 0,1 s"},{"name":"正弦信号","range":"10 kHz to 40 GHz","cmc":"3 · 10⁻¹⁰ · f，平均时间 ≥ 0,1 s"},{"name":"正弦信号","range":"1 kHz 至 10 kHz","cmc":"1 · 10⁻¹⁰ · f"},{"name":"正弦信号","range":"100 Hz 至 1 kHz","cmc":"1 · 10⁻⁹ · f"},{"name":"正弦信号","range":"1 Hz to 100 Hz","cmc":"5 · 10⁻⁸ · f"},{"name":"正弦信号","range":"0,1 Hz to 1 Hz","cmc":"1 · 10⁻⁷ · f"}],"regulatory_area_zh":"频率","search_zh":"数字频率计（包括内置于功率计等中的频率计） 校准 — 频率 内部程序；在固定地点 (S) 及固定地点以外 (P) 频率 内部程序 在固定地点 (S) 及固定地点以外 (P) 方波信号 正弦信号 正弦信号 正弦信号 正弦信号 正弦信号 LMEEiO/16 LMEEiO/31","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"数字频率计（包括内置于功率计等中的频率计）","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"obdélníkový signál","range":"0,001 Hz to 100 MHz","cmc":"3 · 10⁻¹⁰ · f při době průměrování ≥ 0,1 s"},{"name":"sinusový signál","range":"10 kHz to 40 GHz","cmc":"3 · 10⁻¹⁰ · f při době průměrování ≥ 0,1 s"},{"name":"sinusový signál","range":"1 kHz až 10 kHz","cmc":"1 · 10⁻¹⁰ · f"},{"name":"sinusový signál","range":"100 Hz až 1 kHz","cmc":"1 · 10⁻⁹ · f"},{"name":"sinusový signál","range":"1 Hz to 100 Hz","cmc":"5 · 10⁻⁸ · f"},{"name":"sinusový signál","range":"0,1 Hz to 1 Hz","cmc":"1 · 10⁻⁷ · f"}],"regulatory_area_cs":"Frekvence","search_cs":"Digitální měřiče kmitočtu (včetně měřičů kmitočtu vestavěných např. v měřičích výkonu) Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Frekvence Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) obdélníkový signál sinusový signál sinusový signál sinusový signál sinusový signál sinusový signál LMEEiO/16 LMEEiO/31","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Digitální měřiče kmitočtu (včetně měřičů kmitočtu vestavěných např. v měřičích výkonu)"},{"_id":"9173f5fc6bd38640ad209274","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki częstotliwości cyfrowe (w tym mierniki częstotliwości wbudowane np. w mierniki mocy)","test_object_en":"Digital frequency meters (including frequency meters built into e.g. power meters)","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"sygnał prostokątny","range":"0,001 Hz do 100 MHz","cmc":"1 · 10⁻¹¹ · f w czasie uśredniania ≥ 1 s"},{"name":"sygnał sinusoidalny","range":"10 kHz do 40 GHz","cmc":"1 · 10⁻¹¹ · f w czasie uśredniania ≥ 1 s"}],"parameters_en":[{"name":"square wave signal","range":"0,001 Hz to 100 MHz","cmc":"1 · 10⁻¹¹ · f at averaging time ≥ 1 s"},{"name":"sinusoidal signal","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹¹ · f at averaging time ≥ 1 s"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\nsygnał prostokątny 0,001 Hz do 100 MHz CMC 1 · 10⁻¹¹ · f w czasie uśredniania ≥ 1 s\nsygnał sinusoidalny 10 kHz do 40 GHz CMC 1 · 10⁻¹¹ · f w czasie uśredniania ≥ 1 s\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LMEEiO/16\nLMEEiO/31","norm_bases":["LMEEiO/16","LMEEiO/31"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":"f – wielkość mierzona (Hz). Czas uśredniania nie mniejszy niż okres sygnału, ale w zakresie 1 Hz ÷10 Hz liczba uśrednianych okresów nie mniejsza niż 10","note_en":"f – measured value (Hz). Averaging time not shorter than the signal period, but in the range 1 Hz ÷10 Hz the number of averaged periods not less than 10","search_text":"Mierniki częstotliwości cyfrowe (w tym mierniki częstotliwości wbudowane np. w mierniki mocy) Wzorcowanie — Częstotliwość\nZakres:\nsygnał prostokątny 0,001 Hz do 100 MHz CMC 1 · 10⁻¹¹ · f w czasie uśredniania ≥ 1 s\nsygnał sinusoidalny 10 kHz do 40 GHz CMC 1 · 10⁻¹¹ · f w czasie uśredniania ≥ 1 s\nProcedura wewnętrzna; W stałej lokalizacji (S) LMEEiO/16\nLMEEiO/31 Mierniki czestotliwosci cyfrowe (w tym mierniki czestotliwosci wbudowane np. w mierniki mocy) Wzorcowanie — Czestotliwosc\nZakres:\nsygnal prostokatny 0,001 Hz do 100 MHz CMC 1 · 10⁻¹¹ · f w czasie usredniania ≥ 1 s\nsygnal sinusoidalny 10 kHz do 40 GHz CMC 1 · 10⁻¹¹ · f w czasie usredniania ≥ 1 s\nProcedura wewnetrzna; W stalej lokalizacji (S) LMEEiO/16\nLMEEiO/31","search_en":"Digital frequency meters (including frequency meters built into e.g. power meters) Calibration — Frequency Internal procedure; At permanent location (S) Frequency Internal procedure At permanent location (S) square wave signal sinusoidal signal LMEEiO/16 LMEEiO/31","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":74,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"Rechtecksignal","range":"0,001 Hz to 100 MHz","cmc":"1 · 10⁻¹¹ · f bei Mittelungszeit ≥ 1 s"},{"name":"Sinussignal","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹¹ · f bei Mittelungszeit ≥ 1 s"}],"regulatory_area_de":"Frequenz","search_de":"Digitale Frequenzmesser (einschließlich z. B. in Leistungsmesser eingebauter Frequenzmesser) Kalibrierung — Frequenz Internes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Am festen Standort (S) Rechtecksignal Sinussignal LMEEiO/16 LMEEiO/31","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Frequenzmesser (einschließlich z. B. in Leistungsmesser eingebauter Frequenzmesser)","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"方波信号","range":"0,001 Hz to 100 MHz","cmc":"1 · 10⁻¹¹ · f，平均时间 ≥ 1 s"},{"name":"正弦信号","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹¹ · f，平均时间 ≥ 1 s"}],"regulatory_area_zh":"频率","search_zh":"数字频率计（包括内置于功率计等中的频率计） 校准 — 频率 内部程序；在固定地点 (S) 频率 内部程序 在固定地点 (S) 方波信号 正弦信号 LMEEiO/16 LMEEiO/31","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"数字频率计（包括内置于功率计等中的频率计）","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"obdélníkový signál","range":"0,001 Hz to 100 MHz","cmc":"1 · 10⁻¹¹ · f při době průměrování ≥ 1 s"},{"name":"sinusový signál","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹¹ · f při době průměrování ≥ 1 s"}],"regulatory_area_cs":"Frekvence","search_cs":"Digitální měřiče kmitočtu (včetně měřičů kmitočtu vestavěných např. v měřičích výkonu) Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) Frekvence Vnitřní postup Ve stálé lokalitě (S) obdélníkový signál sinusový signál LMEEiO/16 LMEEiO/31","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální měřiče kmitočtu (včetně měřičů kmitočtu vestavěných např. v měřičích výkonu)"},{"_id":"69594838e34bc218d4c26c85","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki częstotliwości cyfrowe (w tym mierniki częstotliwości wbudowane np. w mierniki mocy)","test_object_en":"Digital frequency meters (including frequency meters built into e.g. power meters)","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"sygnał prostokątny","range":"0,001 Hz do 100 MHz","cmc":"1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s"},{"name":"sygnał sinusoidalny","range":"10 kHz do 40 GHz","cmc":"1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s"}],"parameters_en":[{"name":"square wave signal","range":"0,001 Hz to 100 MHz","cmc":"1 · 10⁻¹⁰ · f at averaging time ≥ 1 s"},{"name":"sinusoidal signal","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹⁰ · f at averaging time ≥ 1 s"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\nsygnał prostokątny 0,001 Hz do 100 MHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s\nsygnał sinusoidalny 10 kHz do 40 GHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"LMEEiO/16\nLMEEiO/31","norm_bases":["LMEEiO/16","LMEEiO/31"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"P","note":"f – wielkość mierzona (Hz). Czas uśredniania nie mniejszy niż okres sygnału, ale w zakresie 1 Hz ÷10 Hz liczba uśrednianych okresów nie mniejsza niż 10","note_en":"f – measured value (Hz). Averaging time not shorter than the signal period, but in the range 1 Hz ÷10 Hz the number of averaged periods not less than 10","search_text":"Mierniki częstotliwości cyfrowe (w tym mierniki częstotliwości wbudowane np. w mierniki mocy) Wzorcowanie — Częstotliwość\nZakres:\nsygnał prostokątny 0,001 Hz do 100 MHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s\nsygnał sinusoidalny 10 kHz do 40 GHz CMC 1 · 10⁻¹⁰ · f w czasie uśredniania ≥ 1 s\nProcedura wewnętrzna; Poza stałą lokalizacją (P) LMEEiO/16\nLMEEiO/31 Mierniki czestotliwosci cyfrowe (w tym mierniki czestotliwosci wbudowane np. w mierniki mocy) Wzorcowanie — Czestotliwosc\nZakres:\nsygnal prostokatny 0,001 Hz do 100 MHz CMC 1 · 10⁻¹⁰ · f w czasie usredniania ≥ 1 s\nsygnal sinusoidalny 10 kHz do 40 GHz CMC 1 · 10⁻¹⁰ · f w czasie usredniania ≥ 1 s\nProcedura wewnetrzna; Poza stala lokalizacja (P) LMEEiO/16\nLMEEiO/31","search_en":"Digital frequency meters (including frequency meters built into e.g. power meters) Calibration — Frequency Internal procedure; Outside of permanent location (P) Frequency Internal procedure Outside of permanent location (P) square wave signal sinusoidal signal LMEEiO/16 LMEEiO/31","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":75,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"Rechtecksignal","range":"0,001 Hz to 100 MHz","cmc":"1 · 10⁻¹⁰ · f bei Mittelungszeit ≥ 1 s"},{"name":"Sinussignal","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹⁰ · f bei Mittelungszeit ≥ 1 s"}],"regulatory_area_de":"Frequenz","search_de":"Digitale Frequenzmesser (einschließlich z. B. in Leistungsmesser eingebauter Frequenzmesser) Kalibrierung — Frequenz Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Frequenz Internes Verfahren Außerhalb des festen Standorts (P) Rechtecksignal Sinussignal LMEEiO/16 LMEEiO/31","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Digitale Frequenzmesser (einschließlich z. B. in Leistungsmesser eingebauter Frequenzmesser)","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"方波信号","range":"0,001 Hz to 100 MHz","cmc":"1 · 10⁻¹⁰ · f，平均时间 ≥ 1 s"},{"name":"正弦信号","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹⁰ · f，平均时间 ≥ 1 s"}],"regulatory_area_zh":"频率","search_zh":"数字频率计（包括内置于功率计等中的频率计） 校准 — 频率 内部程序；固定地点以外 (P) 频率 内部程序 固定地点以外 (P) 方波信号 正弦信号 LMEEiO/16 LMEEiO/31","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"数字频率计（包括内置于功率计等中的频率计）","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"obdélníkový signál","range":"0,001 Hz to 100 MHz","cmc":"1 · 10⁻¹⁰ · f při době průměrování ≥ 1 s"},{"name":"sinusový signál","range":"10 kHz to 40 GHz","cmc":"1 · 10⁻¹⁰ · f při době průměrování ≥ 1 s"}],"regulatory_area_cs":"Frekvence","search_cs":"Digitální měřiče kmitočtu (včetně měřičů kmitočtu vestavěných např. v měřičích výkonu) Kalibrace — Kmitočet Vnitřní postup; Mimo stálé pracoviště (P) Frekvence Vnitřní postup Mimo stálou lokalitu (P) obdélníkový signál sinusový signál LMEEiO/16 LMEEiO/31","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Digitální měřiče kmitočtu (včetně měřičů kmitočtu vestavěných např. v měřičích výkonu)"},{"_id":"f42ccb035c9963438c7a6bc6","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki częstotliwości cyfrowe stanowiące część składową innych przyrządów pomiarowych np. mierników uniwersalnych","test_object_en":"Digital frequency meters forming part of other measuring instruments, e.g. universal meters","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"0,1 Hz do 10 MHz","cmc":"0,6 · Δ₁ ale nie lepiej niż 0,001 %"}],"parameters_en":[{"name":"","range":"0,1 Hz to 10 MHz","cmc":"0,6 · Δ₁ but not better than 0,001 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n0,1 Hz do 10 MHz CMC 0,6 · Δ₁ ale nie lepiej niż 0,001 %\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/2","norm_bases":["LMEEiO/2"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"S, P","note":"Δ₁- rozdzielczość odczytu wzorcowanego przyrządu dla sygnału prostokątnego","note_en":"Δ₁ – reading resolution of the calibrated instrument for a square wave signal","search_text":"Mierniki częstotliwości cyfrowe stanowiące część składową innych przyrządów pomiarowych np. mierników uniwersalnych Wzorcowanie — Częstotliwość\n0,1 Hz do 10 MHz CMC 0,6 · Δ₁ ale nie lepiej niż 0,001 %\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/2 Mierniki czestotliwosci cyfrowe stanowiace czesc skladowa innych przyrzadow pomiarowych np. miernikow uniwersalnych Wzorcowanie — Czestotliwosc\n0,1 Hz do 10 MHz CMC 0,6 · Δ₁ ale nie lepiej niz 0,001 %\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/2","search_en":"Digital frequency meters forming part of other measuring instruments, e.g. universal meters Calibration — Frequency Internal procedure; At permanent location (S) and outside of it (P) Frequency Internal procedure At permanent location (S) and outside of it (P) LMEEiO/2","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":76,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"0,1 Hz to 10 MHz","cmc":"0,6 · Δ₁, jedoch nicht besser als 0,001 %"}],"regulatory_area_de":"Frequenz","search_de":"Digitale Frequenzmesser als Bestandteil anderer Messgeräte, z. B. von Universalmessgeräten Kalibrierung — Frequenz Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Frequenz Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/2","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Digitale Frequenzmesser als Bestandteil anderer Messgeräte, z. B. von Universalmessgeräten","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"0,1 Hz to 10 MHz","cmc":"0,6 · Δ₁，但不优于 0,001 %"}],"regulatory_area_zh":"频率","search_zh":"作为其他测量仪器（如万用表）组成部分的数字频率计 校准 — 频率 内部程序；在固定地点 (S) 及固定地点以外 (P) 频率 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/2","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"作为其他测量仪器（如万用表）组成部分的数字频率计","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"0,1 Hz to 10 MHz","cmc":"0,6 · Δ₁, avšak ne lépe než 0,001 %"}],"regulatory_area_cs":"Frekvence","search_cs":"Digitální měřiče kmitočtu tvořící součást jiných měřicích přístrojů, např. univerzálních měřičů Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Frekvence Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/2","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Digitální měřiče kmitočtu tvořící součást jiných měřicích přístrojů, např. univerzálních měřičů"},{"_id":"3022af23e222ba3628b3bb25","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Komparatory częstotliwości\n- względne odchylenie częstotliwości","test_object_en":"Frequency comparators\n- relative frequency deviation","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"f = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","range":"10⁻¹² do 10⁻⁷ Hz/Hz","cmc":"1 · 10⁻¹³ Hz/Hz w czasie uśredniania ≥ 1 d"},{"name":"f = 0,1 Hz do 1,2 GHz","range":"10⁻¹⁰ do 10⁻⁷ Hz/Hz","cmc":"2 · 10⁻¹² Hz/Hz w czasie uśredniania 1000 s"},{"name":"f = 0,1 Hz do 1,2 GHz","range":"10⁻¹⁰ do 10⁻⁷ Hz/Hz","cmc":"1 · 10⁻¹¹ Hz/Hz w czasie uśredniania 10 s"},{"name":"f = 0,1 Hz do 1,2 GHz","range":"10⁻¹⁰ do 10⁻⁷ Hz/Hz","cmc":"5 · 10⁻¹¹ Hz/Hz w czasie uśredniania 1 s"}],"parameters_en":[{"name":"f = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","range":"10⁻¹² to 10⁻⁷ Hz/Hz","cmc":"1 · 10⁻¹³ Hz/Hz at averaging time ≥ 1 d"},{"name":"f = 0,1 Hz to 1,2 GHz","range":"10⁻¹⁰ to 10⁻⁷ Hz/Hz","cmc":"2 · 10⁻¹² Hz/Hz at averaging time 1000 s"},{"name":"f = 0,1 Hz to 1,2 GHz","range":"10⁻¹⁰ to 10⁻⁷ Hz/Hz","cmc":"1 · 10⁻¹¹ Hz/Hz at averaging time 10 s"},{"name":"f = 0,1 Hz to 1,2 GHz","range":"10⁻¹⁰ to 10⁻⁷ Hz/Hz","cmc":"5 · 10⁻¹¹ Hz/Hz at averaging time 1 s"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\nf = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz 10⁻¹² do 10⁻⁷ Hz/Hz CMC 1 · 10⁻¹³ Hz/Hz w czasie uśredniania ≥ 1 d\nf = 0,1 Hz do 1,2 GHz 10⁻¹⁰ do 10⁻⁷ Hz/Hz CMC 2 · 10⁻¹² Hz/Hz w czasie uśredniania 1000 s\nf = 0,1 Hz do 1,2 GHz 10⁻¹⁰ do 10⁻⁷ Hz/Hz CMC 1 · 10⁻¹¹ Hz/Hz w czasie uśredniania 10 s\nf = 0,1 Hz do 1,2 GHz 10⁻¹⁰ do 10⁻⁷ Hz/Hz CMC 5 · 10⁻¹¹ Hz/Hz w czasie uśredniania 1 s\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LMEEiO/18","norm_bases":["LMEEiO/18"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Komparatory częstotliwości\n- względne odchylenie częstotliwości Wzorcowanie — Częstotliwość\nZakres:\nf = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz 10⁻¹² do 10⁻⁷ Hz/Hz CMC 1 · 10⁻¹³ Hz/Hz w czasie uśredniania ≥ 1 d\nf = 0,1 Hz do 1,2 GHz 10⁻¹⁰ do 10⁻⁷ Hz/Hz CMC 2 · 10⁻¹² Hz/Hz w czasie uśredniania 1000 s\nf = 0,1 Hz do 1,2 GHz 10⁻¹⁰ do 10⁻⁷ Hz/Hz CMC 1 · 10⁻¹¹ Hz/Hz w czasie uśredniania 10 s\nf = 0,1 Hz do 1,2 GHz 10⁻¹⁰ do 10⁻⁷ Hz/Hz CMC 5 · 10⁻¹¹ Hz/Hz w czasie uśredniania 1 s\nProcedura wewnętrzna; W stałej lokalizacji (S) LMEEiO/18 Komparatory czestotliwosci\n- wzgledne odchylenie czestotliwosci Wzorcowanie — Czestotliwosc\nZakres:\nf = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz 10⁻¹² do 10⁻⁷ Hz/Hz CMC 1 · 10⁻¹³ Hz/Hz w czasie usredniania ≥ 1 d\nf = 0,1 Hz do 1,2 GHz 10⁻¹⁰ do 10⁻⁷ Hz/Hz CMC 2 · 10⁻¹² Hz/Hz w czasie usredniania 1000 s\nf = 0,1 Hz do 1,2 GHz 10⁻¹⁰ do 10⁻⁷ Hz/Hz CMC 1 · 10⁻¹¹ Hz/Hz w czasie usredniania 10 s\nf = 0,1 Hz do 1,2 GHz 10⁻¹⁰ do 10⁻⁷ Hz/Hz CMC 5 · 10⁻¹¹ Hz/Hz w czasie usredniania 1 s\nProcedura wewnetrzna; W stalej lokalizacji (S) LMEEiO/18","search_en":"Frequency comparators - relative frequency deviation Calibration — Frequency Internal procedure; At permanent location (S) Frequency Internal procedure At permanent location (S) f = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz f = 0,1 Hz to 1,2 GHz f = 0,1 Hz to 1,2 GHz f = 0,1 Hz to 1,2 GHz LMEEiO/18","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":77,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"f = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","range":"10⁻¹² to 10⁻⁷ Hz/Hz","cmc":"1 · 10⁻¹³ Hz/Hz bei Mittelungszeit ≥ 1 d"},{"name":"f = 0,1 Hz bis 1,2 GHz","range":"10⁻¹⁰ to 10⁻⁷ Hz/Hz","cmc":"2 · 10⁻¹² Hz/Hz bei Mittelungszeit 1000 s"},{"name":"f = 0,1 Hz bis 1,2 GHz","range":"10⁻¹⁰ to 10⁻⁷ Hz/Hz","cmc":"1 · 10⁻¹¹ Hz/Hz bei Mittelungszeit 10 s"},{"name":"f = 0,1 Hz bis 1,2 GHz","range":"10⁻¹⁰ to 10⁻⁷ Hz/Hz","cmc":"5 · 10⁻¹¹ Hz/Hz bei Mittelungszeit 1 s"}],"regulatory_area_de":"Frequenz","search_de":"Frequenzkomparatoren - relative Frequenzabweichung Kalibrierung — Frequenz Internes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Am festen Standort (S) f = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz f = 0,1 Hz bis 1,2 GHz f = 0,1 Hz bis 1,2 GHz f = 0,1 Hz bis 1,2 GHz LMEEiO/18","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Frequenzkomparatoren\n- relative Frequenzabweichung","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"f = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","range":"10⁻¹² to 10⁻⁷ Hz/Hz","cmc":"1 · 10⁻¹³ Hz/Hz，平均时间 ≥ 1 d"},{"name":"f = 0,1 Hz 至 1,2 GHz","range":"10⁻¹⁰ to 10⁻⁷ Hz/Hz","cmc":"2 · 10⁻¹² Hz/Hz，平均时间 1000 s"},{"name":"f = 0,1 Hz 至 1,2 GHz","range":"10⁻¹⁰ to 10⁻⁷ Hz/Hz","cmc":"1 · 10⁻¹¹ Hz/Hz，平均时间 10 s"},{"name":"f = 0,1 Hz 至 1,2 GHz","range":"10⁻¹⁰ to 10⁻⁷ Hz/Hz","cmc":"5 · 10⁻¹¹ Hz/Hz，平均时间 1 s"}],"regulatory_area_zh":"频率","search_zh":"频率比较器 - 相对频率偏差 校准 — 频率 内部程序；在固定地点 (S) 频率 内部程序 在固定地点 (S) f = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz f = 0,1 Hz 至 1,2 GHz f = 0,1 Hz 至 1,2 GHz f = 0,1 Hz 至 1,2 GHz LMEEiO/18","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"频率比较器\n- 相对频率偏差","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"f = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz","range":"10⁻¹² to 10⁻⁷ Hz/Hz","cmc":"1 · 10⁻¹³ Hz/Hz při době průměrování ≥ 1 d"},{"name":"f = 0,1 Hz až 1,2 GHz","range":"10⁻¹⁰ to 10⁻⁷ Hz/Hz","cmc":"2 · 10⁻¹² Hz/Hz při době průměrování 1000 s"},{"name":"f = 0,1 Hz až 1,2 GHz","range":"10⁻¹⁰ to 10⁻⁷ Hz/Hz","cmc":"1 · 10⁻¹¹ Hz/Hz při době průměrování 10 s"},{"name":"f = 0,1 Hz až 1,2 GHz","range":"10⁻¹⁰ to 10⁻⁷ Hz/Hz","cmc":"5 · 10⁻¹¹ Hz/Hz při době průměrování 1 s"}],"regulatory_area_cs":"Frekvence","search_cs":"Komparátory kmitočtu - relativní odchylka kmitočtu Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) Frekvence Vnitřní postup Ve stálé lokalitě (S) f = 100 kHz, 1 MHz, 2,048 MHz, 5 MHz, 10 MHz f = 0,1 Hz až 1,2 GHz f = 0,1 Hz až 1,2 GHz f = 0,1 Hz až 1,2 GHz LMEEiO/18","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Komparátory kmitočtu\n- relativní odchylka kmitočtu"},{"_id":"0e66736f59a6916b20335558","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Oscyloskopy\n- wewnętrzne źródła odniesienia AC","test_object_en":"Oscilloscopes\n- internal AC reference sources","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"100 Hz do 10 kHz","cmc":"0,4 · 10⁻⁶ · f"}],"parameters_en":[{"name":"","range":"100 Hz to 10 kHz","cmc":"0,4 · 10⁻⁶ · f"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n100 Hz do 10 kHz CMC 0,4 · 10⁻⁶ · f\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/13","norm_bases":["LMEEiO/13"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"S, P","note":"f – wielkość mierzona (Hz)","note_en":"f – measured value (Hz)","search_text":"Oscyloskopy\n- wewnętrzne źródła odniesienia AC Wzorcowanie — Częstotliwość\n100 Hz do 10 kHz CMC 0,4 · 10⁻⁶ · f\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/13 Oscyloskopy\n- wewnetrzne zrodla odniesienia AC Wzorcowanie — Czestotliwosc\n100 Hz do 10 kHz CMC 0,4 · 10⁻⁶ · f\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/13","search_en":"Oscilloscopes - internal AC reference sources Calibration — Frequency Internal procedure; Direct method; At permanent location (S) and outside of it (P) Frequency Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/13","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":78,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"100 Hz bis 10 kHz","cmc":"0,4 · 10⁻⁶ · f"}],"regulatory_area_de":"Frequenz","search_de":"Oszilloskope - interne AC-Referenzquellen Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/13","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Oszilloskope\n- interne AC-Referenzquellen","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"100 Hz to 10 kHz","cmc":"0,4 · 10⁻⁶ · f"}],"regulatory_area_zh":"频率","search_zh":"示波器 - 内部交流参考源 校准 — 频率 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 频率 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/13","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"示波器\n- 内部交流参考源","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"100 Hz to 10 kHz","cmc":"0,4 · 10⁻⁶ · f"}],"regulatory_area_cs":"Frekvence","search_cs":"Osciloskopy - vnitřní referenční zdroje AC Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Frekvence Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/13","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Osciloskopy\n- vnitřní referenční zdroje AC"},{"_id":"3a07c20e46e3204c96f928b3","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Źródła sinusoidalnych sygnałów pomiarowych (generatory)\nKalibratory","test_object_en":"Sinusoidal measuring signal sources (generators)\nCalibrators","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"10 Hz do 100 Hz","cmc":"5·10⁻⁶ · f"},{"name":"","range":"100 Hz do 100 MHz","cmc":"5·10⁻⁸ · f"}],"parameters_en":[{"name":"","range":"10 Hz to 100 Hz","cmc":"5·10⁻⁶ · f"},{"name":"","range":"100 Hz to 100 MHz","cmc":"5·10⁻⁸ · f"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\n10 Hz do 100 Hz CMC 5·10⁻⁶ · f\n100 Hz do 100 MHz CMC 5·10⁻⁸ · f\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/3LMEEiO/10\nLMEEiO/42","norm_bases":["LMEEiO/3","LMEEiO/10","LMEEiO/42"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":"f – wielkość mierzona (Hz)","note_en":"f – measured value (Hz)","search_text":"Źródła sinusoidalnych sygnałów pomiarowych (generatory)\nKalibratory Wzorcowanie — Częstotliwość\nZakres:\n10 Hz do 100 Hz CMC 5·10⁻⁶ · f\n100 Hz do 100 MHz CMC 5·10⁻⁸ · f\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/3LMEEiO/10\nLMEEiO/42 Zrodla sinusoidalnych sygnalow pomiarowych (generatory)\nKalibratory Wzorcowanie — Czestotliwosc\nZakres:\n10 Hz do 100 Hz CMC 5·10⁻⁶ · f\n100 Hz do 100 MHz CMC 5·10⁻⁸ · f\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/3LMEEiO/10\nLMEEiO/42","search_en":"Sinusoidal measuring signal sources (generators) Calibrators Calibration — Frequency Internal procedure; Direct method; At permanent location (S) Frequency Internal procedure Direct method At permanent location (S) LMEEiO/3LMEEiO/10 LMEEiO/42","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":79,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"10 Hz bis 100 Hz","cmc":"5·10⁻⁶ · f"},{"name":"","range":"100 Hz to 100 MHz","cmc":"5·10⁻⁸ · f"}],"regulatory_area_de":"Frequenz","search_de":"Quellen sinusförmiger Messsignale (Generatoren) Kalibratoren Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) LMEEiO/3LMEEiO/10 LMEEiO/42","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Quellen sinusförmiger Messsignale (Generatoren)\nKalibratoren","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"10 Hz to 100 Hz","cmc":"5·10⁻⁶ · f"},{"name":"","range":"100 Hz to 100 MHz","cmc":"5·10⁻⁸ · f"}],"regulatory_area_zh":"频率","search_zh":"正弦测量信号源（发生器） 校准器 校准 — 频率 内部程序；直接法；在固定地点 (S) 频率 内部程序 直接法 在固定地点 (S) LMEEiO/3LMEEiO/10 LMEEiO/42","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"正弦测量信号源（发生器）\n校准器","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"10 Hz to 100 Hz","cmc":"5·10⁻⁶ · f"},{"name":"","range":"100 Hz to 100 MHz","cmc":"5·10⁻⁸ · f"}],"regulatory_area_cs":"Frekvence","search_cs":"Zdroje sinusových měřicích signálů (generátory) Kalibrátory Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Frekvence Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LMEEiO/3LMEEiO/10 LMEEiO/42","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Zdroje sinusových měřicích signálů (generátory)\nKalibrátory"},{"_id":"b65602d3712a34c4ed6fa804","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki sinusoidalnych sygnałów pomiarowych (mierniki)","test_object_en":"Sinusoidal measuring signal meters (meters)","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"10 Hz do 50 MHz","cmc":"0,6 · Δ₂"}],"parameters_en":[{"name":"","range":"10 Hz to 50 MHz","cmc":"0,6 · Δ₂"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n10 Hz do 50 MHz CMC 0,6 · Δ₂\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/11\nLMEEiO/42","norm_bases":["LMEEiO/11","LMEEiO/42"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":"Δ₂- rozdzielczość odczytu wzorcowanego przyrządu (wyświetlacz max 6 cyfr)","note_en":"Δ₂ – reading resolution of the calibrated instrument (display max. 6 digits)","search_text":"Mierniki sinusoidalnych sygnałów pomiarowych (mierniki) Wzorcowanie — Częstotliwość\n10 Hz do 50 MHz CMC 0,6 · Δ₂\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/11\nLMEEiO/42 Mierniki sinusoidalnych sygnalow pomiarowych (mierniki) Wzorcowanie — Czestotliwosc\n10 Hz do 50 MHz CMC 0,6 · Δ₂\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/11\nLMEEiO/42","search_en":"Sinusoidal measuring signal meters (meters) Calibration — Frequency Internal procedure; Direct method; At permanent location (S) Frequency Internal procedure Direct method At permanent location (S) LMEEiO/11 LMEEiO/42","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":80,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"10 Hz to 50 MHz","cmc":"0,6 · Δ₂"}],"regulatory_area_de":"Frequenz","search_de":"Messgeräte für sinusförmige Messsignale (Messgeräte) Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) LMEEiO/11 LMEEiO/42","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Messgeräte für sinusförmige Messsignale (Messgeräte)","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"10 Hz to 50 MHz","cmc":"0,6 · Δ₂"}],"regulatory_area_zh":"频率","search_zh":"正弦测量信号测量仪（测量仪） 校准 — 频率 内部程序；直接法；在固定地点 (S) 频率 内部程序 直接法 在固定地点 (S) LMEEiO/11 LMEEiO/42","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"正弦测量信号测量仪（测量仪）","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"10 Hz to 50 MHz","cmc":"0,6 · Δ₂"}],"regulatory_area_cs":"Frekvence","search_cs":"Měřiče sinusových měřicích signálů (měřiče) Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Frekvence Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LMEEiO/11 LMEEiO/42","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče sinusových měřicích signálů (měřiče)"},{"_id":"2f6ec91049f30c62ac5d09ac","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Kalibratory\nMierniki (mostki) RLC\nMierniki (mostki) impedancji","test_object_en":"Calibrators\nRLC meters (bridges)\nImpedance meters (bridges)","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"10 Hz do 10 MHz","cmc":"0,001 %"}],"parameters_en":[{"name":"","range":"10 Hz to 10 MHz","cmc":"0,001 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n10 Hz do 10 MHz CMC 0,001 %\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/3\nLMEEiO/5","norm_bases":["LMEEiO/3","LMEEiO/5"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Kalibratory\nMierniki (mostki) RLC\nMierniki (mostki) impedancji Wzorcowanie — Częstotliwość\n10 Hz do 10 MHz CMC 0,001 %\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/3\nLMEEiO/5 Kalibratory\nMierniki (mostki) RLC\nMierniki (mostki) impedancji Wzorcowanie — Czestotliwosc\n10 Hz do 10 MHz CMC 0,001 %\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/3\nLMEEiO/5","search_en":"Calibrators RLC meters (bridges) Impedance meters (bridges) Calibration — Frequency Internal procedure; At permanent location (S) and outside of it (P) Frequency Internal procedure At permanent location (S) and outside of it (P) LMEEiO/3 LMEEiO/5","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":81,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"10 Hz to 10 MHz","cmc":"0,001 %"}],"regulatory_area_de":"Frequenz","search_de":"Kalibratoren RLC-Messgeräte (Messbrücken) Impedanzmessgeräte (Messbrücken) Kalibrierung — Frequenz Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Frequenz Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/3 LMEEiO/5","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nRLC-Messgeräte (Messbrücken)\nImpedanzmessgeräte (Messbrücken)","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"10 Hz to 10 MHz","cmc":"0,001 %"}],"regulatory_area_zh":"频率","search_zh":"校准器 RLC 测量仪（电桥） 阻抗测量仪（电桥） 校准 — 频率 内部程序；在固定地点 (S) 及固定地点以外 (P) 频率 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/3 LMEEiO/5","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\nRLC 测量仪（电桥）\n阻抗测量仪（电桥）","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"10 Hz to 10 MHz","cmc":"0,001 %"}],"regulatory_area_cs":"Frekvence","search_cs":"Kalibrátory Měřiče (můstky) RLC Měřiče (můstky) impedance Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Frekvence Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/3 LMEEiO/5","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nMěřiče (můstky) RLC\nMěřiče (můstky) impedance"},{"_id":"8275d7fa1a45330ee5b85db5","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Źródła promieniowania optycznego (modulowane i niemodulowane)\nZestawy do pomiaru tłumienności","test_object_en":"Optical radiation sources (modulated and unmodulated)\nAttenuation measurement sets","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"1 Hz do 2,5 GHz","cmc":"3 · 10⁻³ Hz"}],"parameters_en":[{"name":"","range":"1 Hz to 2,5 GHz","cmc":"3 · 10⁻³ Hz"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n1 Hz do 2,5 GHz CMC 3 · 10⁻³ Hz\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/22","norm_bases":["LMEEiO/22"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Źródła promieniowania optycznego (modulowane i niemodulowane)\nZestawy do pomiaru tłumienności Wzorcowanie — Częstotliwość\n1 Hz do 2,5 GHz CMC 3 · 10⁻³ Hz\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/22 Zrodla promieniowania optycznego (modulowane i niemodulowane)\nZestawy do pomiaru tlumiennosci Wzorcowanie — Czestotliwosc\n1 Hz do 2,5 GHz CMC 3 · 10⁻³ Hz\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/22","search_en":"Optical radiation sources (modulated and unmodulated) Attenuation measurement sets Calibration — Frequency Internal procedure; At permanent location (S) and outside of it (P) Frequency Internal procedure At permanent location (S) and outside of it (P) LMEEiO/22","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":82,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"1 Hz to 2,5 GHz","cmc":"3 · 10⁻³ Hz"}],"regulatory_area_de":"Frequenz","search_de":"Optische Strahlungsquellen (moduliert und unmoduliert) Dämpfungsmesssätze Kalibrierung — Frequenz Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Frequenz Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/22","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Strahlungsquellen (moduliert und unmoduliert)\nDämpfungsmesssätze","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"1 Hz to 2,5 GHz","cmc":"3 · 10⁻³ Hz"}],"regulatory_area_zh":"频率","search_zh":"光辐射源（调制和未调制） 衰减测量装置 校准 — 频率 内部程序；在固定地点 (S) 及固定地点以外 (P) 频率 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/22","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光辐射源（调制和未调制）\n衰减测量装置","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"1 Hz to 2,5 GHz","cmc":"3 · 10⁻³ Hz"}],"regulatory_area_cs":"Frekvence","search_cs":"Zdroje optického záření (modulované a nemodulované) Soupravy pro měření útlumu Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Frekvence Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/22","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Zdroje optického záření (modulované a nemodulované)\nSoupravy pro měření útlumu"},{"_id":"f1348e15bd2e71ed7c166218","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki tłumienności odbicia","test_object_en":"Return loss meters","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"10 Hz do 100 Hz","cmc":"2,3 · 10⁻⁶ Hz"},{"name":"","range":"100 Hz do 1 kHz","cmc":"2,3 · 10⁻⁵ Hz"},{"name":"","range":"1 kHz do 10 kHz","cmc":"2,3 · 10⁻⁴ Hz"},{"name":"","range":"10 kHz do 100 kHz","cmc":"2,4 · 10⁻³ Hz"},{"name":"","range":"100 kHz do 10 MHz","cmc":"7,0 · 10⁻¹ Hz"},{"name":"","range":"10 MHz do 100 MHz","cmc":"49 Hz"},{"name":"","range":"100 MHz do 1 GHz","cmc":"46 · 10² Hz"},{"name":"","range":"1 GHz do 2,5 GHz","cmc":"46·10⁴ Hz"}],"parameters_en":[{"name":"","range":"10 Hz do 100 Hz","cmc":"2,3 · 10⁻⁶ Hz"},{"name":"","range":"100 Hz do 1 kHz","cmc":"2,3 · 10⁻⁵ Hz"},{"name":"","range":"1 kHz do 10 kHz","cmc":"2,3 · 10⁻⁴ Hz"},{"name":"","range":"10 kHz do 100 kHz","cmc":"2,4 · 10⁻³ Hz"},{"name":"","range":"100 kHz do 10 MHz","cmc":"7,0 · 10⁻¹ Hz"},{"name":"","range":"10 MHz to 100 MHz","cmc":"49 Hz"},{"name":"","range":"100 MHz do 1 GHz","cmc":"46 · 10² Hz"},{"name":"","range":"1 GHz do 2,5 GHz","cmc":"46·10⁴ Hz"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\n10 Hz do 100 Hz CMC 2,3 · 10⁻⁶ Hz\n100 Hz do 1 kHz CMC 2,3 · 10⁻⁵ Hz\n1 kHz do 10 kHz CMC 2,3 · 10⁻⁴ Hz\n10 kHz do 100 kHz CMC 2,4 · 10⁻³ Hz\n100 kHz do 10 MHz CMC 7,0 · 10⁻¹ Hz\n10 MHz do 100 MHz CMC 49 Hz\n100 MHz do 1 GHz CMC 46 · 10² Hz\n1 GHz do 2,5 GHz CMC 46·10⁴ Hz\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/26","norm_bases":["LMEEiO/26"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki tłumienności odbicia Wzorcowanie — Częstotliwość\nZakres:\n10 Hz do 100 Hz CMC 2,3 · 10⁻⁶ Hz\n100 Hz do 1 kHz CMC 2,3 · 10⁻⁵ Hz\n1 kHz do 10 kHz CMC 2,3 · 10⁻⁴ Hz\n10 kHz do 100 kHz CMC 2,4 · 10⁻³ Hz\n100 kHz do 10 MHz CMC 7,0 · 10⁻¹ Hz\n10 MHz do 100 MHz CMC 49 Hz\n100 MHz do 1 GHz CMC 46 · 10² Hz\n1 GHz do 2,5 GHz CMC 46·10⁴ Hz\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/26 Mierniki tlumiennosci odbicia Wzorcowanie — Czestotliwosc\nZakres:\n10 Hz do 100 Hz CMC 2,3 · 10⁻⁶ Hz\n100 Hz do 1 kHz CMC 2,3 · 10⁻⁵ Hz\n1 kHz do 10 kHz CMC 2,3 · 10⁻⁴ Hz\n10 kHz do 100 kHz CMC 2,4 · 10⁻³ Hz\n100 kHz do 10 MHz CMC 7,0 · 10⁻¹ Hz\n10 MHz do 100 MHz CMC 49 Hz\n100 MHz do 1 GHz CMC 46 · 10² Hz\n1 GHz do 2,5 GHz CMC 46·10⁴ Hz\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/26","search_en":"Return loss meters Calibration — Frequency Internal procedure; At permanent location (S) and outside of it (P) Frequency Internal procedure At permanent location (S) and outside of it (P) LMEEiO/26","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":83,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"10 Hz bis 100 Hz","cmc":"2,3 · 10⁻⁶ Hz"},{"name":"","range":"100 Hz bis 1 kHz","cmc":"2,3 · 10⁻⁵ Hz"},{"name":"","range":"1 kHz bis 10 kHz","cmc":"2,3 · 10⁻⁴ Hz"},{"name":"","range":"10 kHz bis 100 kHz","cmc":"2,4 · 10⁻³ Hz"},{"name":"","range":"100 kHz do 10 MHz","cmc":"7,0 · 10⁻¹ Hz"},{"name":"","range":"10 MHz bis 100 MHz","cmc":"49 Hz"},{"name":"","range":"100 MHz bis 1 GHz","cmc":"46 · 10² Hz"},{"name":"","range":"1 GHz do 2,5 GHz","cmc":"46·10⁴ Hz"}],"regulatory_area_de":"Frequenz","search_de":"Rückflussdämpfungsmessgeräte Kalibrierung — Frequenz Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Frequenz Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/26","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Rückflussdämpfungsmessgeräte","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"10 Hz do 100 Hz","cmc":"2,3 · 10⁻⁶ Hz"},{"name":"","range":"100 Hz 至 1 kHz","cmc":"2,3 · 10⁻⁵ Hz"},{"name":"","range":"1 kHz 至 10 kHz","cmc":"2,3 · 10⁻⁴ Hz"},{"name":"","range":"10 kHz 至 100 kHz","cmc":"2,4 · 10⁻³ Hz"},{"name":"","range":"100 kHz do 10 MHz","cmc":"7,0 · 10⁻¹ Hz"},{"name":"","range":"10 MHz 至 100 MHz","cmc":"49 Hz"},{"name":"","range":"100 MHz do 1 GHz","cmc":"46 · 10² Hz"},{"name":"","range":"1 GHz do 2,5 GHz","cmc":"46·10⁴ Hz"}],"regulatory_area_zh":"频率","search_zh":"回波损耗测量仪 校准 — 频率 内部程序；在固定地点 (S) 及固定地点以外 (P) 频率 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/26","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"回波损耗测量仪","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"10 Hz do 100 Hz","cmc":"2,3 · 10⁻⁶ Hz"},{"name":"","range":"100 Hz až 1 kHz","cmc":"2,3 · 10⁻⁵ Hz"},{"name":"","range":"1 kHz až 10 kHz","cmc":"2,3 · 10⁻⁴ Hz"},{"name":"","range":"10 kHz až 100 kHz","cmc":"2,4 · 10⁻³ Hz"},{"name":"","range":"100 kHz do 10 MHz","cmc":"7,0 · 10⁻¹ Hz"},{"name":"","range":"10 MHz až 100 MHz","cmc":"49 Hz"},{"name":"","range":"100 MHz do 1 GHz","cmc":"46 · 10² Hz"},{"name":"","range":"1 GHz do 2,5 GHz","cmc":"46·10⁴ Hz"}],"regulatory_area_cs":"Frekvence","search_cs":"Měřiče útlumu odrazu Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Frekvence Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/26","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče útlumu odrazu"},{"_id":"c4f86d777c1dd7fa7b943183","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki i generatory częstotliwości\nAnalizatorów sygnałów PCM","test_object_en":"Frequency meters and generators\nof PCM signal analysers","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"dla poziom -10 dBm","range":"20 Hz do 100 Hz","cmc":"2,5 · 10⁻⁵ · f"},{"name":"dla poziom -10 dBm","range":"100 Hz do 3403 Hz","cmc":"5 · 10⁻⁶ · f"}],"parameters_en":[{"name":"for level -10 dBm","range":"20 Hz to 100 Hz","cmc":"2,5 · 10⁻⁵ · f"},{"name":"for level -10 dBm","range":"100 Hz to 3403 Hz","cmc":"5 · 10⁻⁶ · f"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\ndla poziom -10 dBm 20 Hz do 100 Hz CMC 2,5 · 10⁻⁵ · f\ndla poziom -10 dBm 100 Hz do 3403 Hz CMC 5 · 10⁻⁶ · f\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/37","norm_bases":["LMEEiO/37"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":"f – wielkość mierzona (Hz)","note_en":"f – measured value (Hz)","search_text":"Mierniki i generatory częstotliwości\nAnalizatorów sygnałów PCM Wzorcowanie — Częstotliwość\nZakres:\ndla poziom -10 dBm 20 Hz do 100 Hz CMC 2,5 · 10⁻⁵ · f\ndla poziom -10 dBm 100 Hz do 3403 Hz CMC 5 · 10⁻⁶ · f\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/37 Mierniki i generatory czestotliwosci\nAnalizatorow sygnalow PCM Wzorcowanie — Czestotliwosc\nZakres:\ndla poziom -10 dBm 20 Hz do 100 Hz CMC 2,5 · 10⁻⁵ · f\ndla poziom -10 dBm 100 Hz do 3403 Hz CMC 5 · 10⁻⁶ · f\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/37","search_en":"Frequency meters and generators of PCM signal analysers Calibration — Frequency Internal procedure; Direct method; At permanent location (S) Frequency Internal procedure Direct method At permanent location (S) for level -10 dBm for level -10 dBm LMEEiO/37","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":84,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"für Pegel -10 dBm","range":"20 Hz bis 100 Hz","cmc":"2,5 · 10⁻⁵ · f"},{"name":"für Pegel -10 dBm","range":"100 Hz to 3403 Hz","cmc":"5 · 10⁻⁶ · f"}],"regulatory_area_de":"Frequenz","search_de":"Frequenzmesser und -generatoren von PCM-Signalanalysatoren Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) für Pegel -10 dBm für Pegel -10 dBm LMEEiO/37","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Frequenzmesser und -generatoren\nvon PCM-Signalanalysatoren","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"电平 -10 dBm 时","range":"20 Hz to 100 Hz","cmc":"2,5 · 10⁻⁵ · f"},{"name":"电平 -10 dBm 时","range":"100 Hz to 3403 Hz","cmc":"5 · 10⁻⁶ · f"}],"regulatory_area_zh":"频率","search_zh":"频率计和频率发生器 PCM 信号分析仪的 校准 — 频率 内部程序；直接法；在固定地点 (S) 频率 内部程序 直接法 在固定地点 (S) 电平 -10 dBm 时 电平 -10 dBm 时 LMEEiO/37","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"频率计和频率发生器\nPCM 信号分析仪的","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"pro úroveň -10 dBm","range":"20 Hz to 100 Hz","cmc":"2,5 · 10⁻⁵ · f"},{"name":"pro úroveň -10 dBm","range":"100 Hz to 3403 Hz","cmc":"5 · 10⁻⁶ · f"}],"regulatory_area_cs":"Frekvence","search_cs":"Měřiče a generátory kmitočtu analyzátorů signálů PCM Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Frekvence Vnitřní postup Přímá metoda Ve stálé lokalitě (S) pro úroveň -10 dBm pro úroveň -10 dBm LMEEiO/37","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče a generátory kmitočtu\nanalyzátorů signálů PCM"},{"_id":"a23b2c9d6db669e672bef989","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory transmisji cyfrowej","test_object_en":"Digital transmission analysers","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"1,544 MHz do 28,6 GHz","cmc":"1 · 10⁻⁹ · f"}],"parameters_en":[{"name":"","range":"1,544 MHz to 28,6 GHz","cmc":"1 · 10⁻⁹ · f"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n1,544 MHz do 28,6 GHz CMC 1 · 10⁻⁹ · f\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/27\nLMEEiO/37","norm_bases":["LMEEiO/27","LMEEiO/37"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"S, P","note":"f – wielkość mierzona (Hz). Pomiar częstotliwości strumieni danych transmitowanych w standardach PDH/SDH. Pomiar częstotliwości pojedynczego strumienia danych transmitowanego w standardach Ethernet i innych","note_en":"f – measured value (Hz). Frequency measurement of data streams transmitted in PDH/SDH standards. Frequency measurement of a single data stream transmitted in Ethernet and other standards","search_text":"Analizatory transmisji cyfrowej Wzorcowanie — Częstotliwość\n1,544 MHz do 28,6 GHz CMC 1 · 10⁻⁹ · f\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/27\nLMEEiO/37 Analizatory transmisji cyfrowej Wzorcowanie — Czestotliwosc\n1,544 MHz do 28,6 GHz CMC 1 · 10⁻⁹ · f\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/27\nLMEEiO/37","search_en":"Digital transmission analysers Calibration — Frequency Internal procedure; Direct method; At permanent location (S) and outside of it (P) Frequency Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/27 LMEEiO/37","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":85,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"1,544 MHz to 28,6 GHz","cmc":"1 · 10⁻⁹ · f"}],"regulatory_area_de":"Frequenz","search_de":"Analysatoren für digitale Übertragung Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/27 LMEEiO/37","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Analysatoren für digitale Übertragung","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"1,544 MHz to 28,6 GHz","cmc":"1 · 10⁻⁹ · f"}],"regulatory_area_zh":"频率","search_zh":"数字传输分析仪 校准 — 频率 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 频率 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/27 LMEEiO/37","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"数字传输分析仪","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"1,544 MHz to 28,6 GHz","cmc":"1 · 10⁻⁹ · f"}],"regulatory_area_cs":"Frekvence","search_cs":"Analyzátory digitálního přenosu Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Frekvence Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/27 LMEEiO/37","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analyzátory digitálního přenosu"},{"_id":"1b67695ac63a8b5f87629cc9","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory transmisji cyfrowej w zakresie interfejsów transmisji danych","test_object_en":"Digital transmission analysers for data transmission interfaces","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"64 kHz do 2048 kHz","cmc":"1 · 10⁻⁸ · f"}],"parameters_en":[{"name":"","range":"64 kHz to 2048 kHz","cmc":"1 · 10⁻⁸ · f"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n64 kHz do 2048 kHz CMC 1 · 10⁻⁸ · f\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/38","norm_bases":["LMEEiO/38"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"S, P","note":"f – wielkość mierzona (Hz)","note_en":"f – measured value (Hz)","search_text":"Analizatory transmisji cyfrowej w zakresie interfejsów transmisji danych Wzorcowanie — Częstotliwość\n64 kHz do 2048 kHz CMC 1 · 10⁻⁸ · f\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/38 Analizatory transmisji cyfrowej w zakresie interfejsow transmisji danych Wzorcowanie — Czestotliwosc\n64 kHz do 2048 kHz CMC 1 · 10⁻⁸ · f\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/38","search_en":"Digital transmission analysers for data transmission interfaces Calibration — Frequency Internal procedure; Direct method; At permanent location (S) and outside of it (P) Frequency Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/38","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":86,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"64 kHz to 2048 kHz","cmc":"1 · 10⁻⁸ · f"}],"regulatory_area_de":"Frequenz","search_de":"Analysatoren für digitale Übertragung im Bereich der Datenübertragungsschnittstellen Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/38","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Analysatoren für digitale Übertragung im Bereich der Datenübertragungsschnittstellen","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"64 kHz to 2048 kHz","cmc":"1 · 10⁻⁸ · f"}],"regulatory_area_zh":"频率","search_zh":"数据传输接口范围内的数字传输分析仪 校准 — 频率 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 频率 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/38","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"数据传输接口范围内的数字传输分析仪","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"64 kHz to 2048 kHz","cmc":"1 · 10⁻⁸ · f"}],"regulatory_area_cs":"Frekvence","search_cs":"Analyzátory digitálního přenosu v oblasti rozhraní datového přenosu Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Frekvence Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/38","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analyzátory digitálního přenosu v oblasti rozhraní datového přenosu"},{"_id":"d570f71efb33b7b0732eadb4","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory widma\nAnalizatory obwodów\nAnalizatory systemów antenowych i kablowych\nOdbiorniki pomiarowe","test_object_en":"Spectrum analysers\nNetwork analysers\nAntenna and cable system analysers\nMeasuring receivers","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"9 kHz do 40 GHz","cmc":"2 · 10⁻¹⁰ · f w czasie uśredniania 1 s"},{"name":"","range":"9 kHz do 40 GHz","cmc":"4 · 10⁻¹¹ · f w czasie uśredniania 0,1 s"}],"parameters_en":[{"name":"","range":"9 kHz to 40 GHz","cmc":"2 · 10⁻¹⁰ · f at averaging time 1 s"},{"name":"","range":"9 kHz to 40 GHz","cmc":"4 · 10⁻¹¹ · f at averaging time 0,1 s"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nZakres:\n9 kHz do 40 GHz CMC 2 · 10⁻¹⁰ · f w czasie uśredniania 1 s\n9 kHz do 40 GHz CMC 4 · 10⁻¹¹ · f w czasie uśredniania 0,1 s\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44","norm_bases":["LMEEiO/39","LMEEiO/40","LMEEiO/41","LMEEiO/43","LMEEiO/44"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"S, P","note":"f – wielkość mierzona (Hz)","note_en":"f – measured value (Hz)","search_text":"Analizatory widma\nAnalizatory obwodów\nAnalizatory systemów antenowych i kablowych\nOdbiorniki pomiarowe Wzorcowanie — Częstotliwość\nZakres:\n9 kHz do 40 GHz CMC 2 · 10⁻¹⁰ · f w czasie uśredniania 1 s\n9 kHz do 40 GHz CMC 4 · 10⁻¹¹ · f w czasie uśredniania 0,1 s\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44 Analizatory widma\nAnalizatory obwodow\nAnalizatory systemow antenowych i kablowych\nOdbiorniki pomiarowe Wzorcowanie — Czestotliwosc\nZakres:\n9 kHz do 40 GHz CMC 2 · 10⁻¹⁰ · f w czasie usredniania 1 s\n9 kHz do 40 GHz CMC 4 · 10⁻¹¹ · f w czasie usredniania 0,1 s\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/39\nLMEEiO/40\nLMEEiO/41\nLMEEiO/43\nLMEEiO/44","search_en":"Spectrum analysers Network analysers Antenna and cable system analysers Measuring receivers Calibration — Frequency Internal procedure; At permanent location (S) and outside of it (P) Frequency Internal procedure At permanent location (S) and outside of it (P) LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":87,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"9 kHz to 40 GHz","cmc":"2 · 10⁻¹⁰ · f bei Mittelungszeit 1 s"},{"name":"","range":"9 kHz to 40 GHz","cmc":"4 · 10⁻¹¹ · f bei Mittelungszeit 0,1 s"}],"regulatory_area_de":"Frequenz","search_de":"Spektrumanalysatoren Netzwerkanalysatoren Analysatoren für Antennen- und Kabelsysteme Messempfänger Kalibrierung — Frequenz Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Frequenz Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Spektrumanalysatoren\nNetzwerkanalysatoren\nAnalysatoren für Antennen- und Kabelsysteme\nMessempfänger","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"9 kHz to 40 GHz","cmc":"2 · 10⁻¹⁰ · f，平均时间 1 s"},{"name":"","range":"9 kHz to 40 GHz","cmc":"4 · 10⁻¹¹ · f，平均时间 0,1 s"}],"regulatory_area_zh":"频率","search_zh":"频谱分析仪 网络分析仪 天线与电缆系统分析仪 测量接收机 校准 — 频率 内部程序；在固定地点 (S) 及固定地点以外 (P) 频率 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"频谱分析仪\n网络分析仪\n天线与电缆系统分析仪\n测量接收机","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"9 kHz to 40 GHz","cmc":"2 · 10⁻¹⁰ · f při době průměrování 1 s"},{"name":"","range":"9 kHz to 40 GHz","cmc":"4 · 10⁻¹¹ · f při době průměrování 0,1 s"}],"regulatory_area_cs":"Frekvence","search_cs":"Spektrální analyzátory Obvodové analyzátory Analyzátory anténních a kabelových systémů Měřicí přijímače Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Frekvence Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/39 LMEEiO/40 LMEEiO/41 LMEEiO/43 LMEEiO/44","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Spektrální analyzátory\nObvodové analyzátory\nAnalyzátory anténních a kabelových systémů\nMěřicí přijímače"},{"_id":"d124118f9b792f7efb98d8a4","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory parametrów i uszkodzeń linii","test_object_en":"Line parameter and fault analysers","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"20 kHz do 1200 kHz","cmc":"0,001 %"}],"parameters_en":[{"name":"","range":"20 kHz to 1200 kHz","cmc":"0,001 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n20 kHz do 1200 kHz CMC 0,001 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/42","norm_bases":["LMEEiO/42"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Analizatory parametrów i uszkodzeń linii Wzorcowanie — Częstotliwość\n20 kHz do 1200 kHz CMC 0,001 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/42 Analizatory parametrow i uszkodzen linii Wzorcowanie — Czestotliwosc\n20 kHz do 1200 kHz CMC 0,001 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/42","search_en":"Line parameter and fault analysers Calibration — Frequency Internal procedure; Direct method; At permanent location (S) Frequency Internal procedure Direct method At permanent location (S) LMEEiO/42","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":88,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"20 kHz to 1200 kHz","cmc":"0,001 %"}],"regulatory_area_de":"Frequenz","search_de":"Leitungsparameter- und Fehleranalysatoren Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) LMEEiO/42","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Leitungsparameter- und Fehleranalysatoren","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"20 kHz to 1200 kHz","cmc":"0,001 %"}],"regulatory_area_zh":"频率","search_zh":"线路参数与故障分析仪 校准 — 频率 内部程序；直接法；在固定地点 (S) 频率 内部程序 直接法 在固定地点 (S) LMEEiO/42","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"线路参数与故障分析仪","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"20 kHz to 1200 kHz","cmc":"0,001 %"}],"regulatory_area_cs":"Frekvence","search_cs":"Analyzátory parametrů a poruch vedení Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Frekvence Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LMEEiO/42","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analyzátory parametrů a poruch vedení"},{"_id":"f64bc581738d16f17e29e6df","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizator jakości energii\n- wahania częstotliwości","test_object_en":"Power quality analyser\n- frequency fluctuations","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"45 Hz do 55 Hz","cmc":"0,2 %"}],"parameters_en":[{"name":"","range":"45 Hz to 55 Hz","cmc":"0,2 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n45 Hz do 55 Hz CMC 0,2 %\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/50","norm_bases":["LMEEiO/50"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Analizator jakości energii\n- wahania częstotliwości Wzorcowanie — Częstotliwość\n45 Hz do 55 Hz CMC 0,2 %\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/50 Analizator jakosci energii\n- wahania czestotliwosci Wzorcowanie — Czestotliwosc\n45 Hz do 55 Hz CMC 0,2 %\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/50","search_en":"Power quality analyser - frequency fluctuations Calibration — Frequency Internal procedure; At permanent location (S) and outside of it (P) Frequency Internal procedure At permanent location (S) and outside of it (P) LMEEiO/50","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":89,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"45 Hz bis 55 Hz","cmc":"0,2 %"}],"regulatory_area_de":"Frequenz","search_de":"Netzqualitätsanalysator - Frequenzschwankungen Kalibrierung — Frequenz Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Frequenz Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/50","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Netzqualitätsanalysator\n- Frequenzschwankungen","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"45 Hz 至 55 Hz","cmc":"0,2 %"}],"regulatory_area_zh":"频率","search_zh":"电能质量分析仪 - 频率波动 校准 — 频率 内部程序；在固定地点 (S) 及固定地点以外 (P) 频率 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/50","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电能质量分析仪\n- 频率波动","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"45 Hz až 55 Hz","cmc":"0,2 %"}],"regulatory_area_cs":"Frekvence","search_cs":"Analyzátor kvality elektrické energie - kolísání kmitočtu Kalibrace — Kmitočet Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Frekvence Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/50","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analyzátor kvality elektrické energie\n- kolísání kmitočtu"},{"_id":"b127bce97782d931a2d70f85","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Higrometry\nTermohigrometry","test_object_en":"Hygrometers\nThermohygrometers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"w zakresie temperatur 10 °C do 20 °C","range":"25 %rh do 95 %rh","cmc":"0,9 %rh"},{"name":"w zakresie temperatur 20 °C do 40 °C","range":"10 %rh do 95 %rh","cmc":"1,0 %rh"},{"name":"w zakresie temperatur 40 °C do 60 °C","range":"10 %rh do 90 %rh","cmc":"1,1 %rh"}],"parameters_en":[{"name":"temperature range 10 °C to 20 °C","range":"25 %rh to 95 %rh","cmc":"0,9 %rh"},{"name":"temperature range 20 °C to 40 °C","range":"10 %rh to 95 %rh","cmc":"1,0 %rh"},{"name":"temperature range 40 °C to 60 °C","range":"10 %rh to 90 %rh","cmc":"1,1 %rh"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nZakres:\nw zakresie temperatur 10 °C do 20 °C 25 %rh do 95 %rh CMC 0,9 %rh\nw zakresie temperatur 20 °C do 40 °C 10 %rh do 95 %rh CMC 1,0 %rh\nw zakresie temperatur 40 °C do 60 °C 10 %rh do 90 %rh CMC 1,1 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/54\nLMEEiO/55","norm_bases":["LMEEiO/54","LMEEiO/55"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Higrometry\nTermohigrometry Wzorcowanie — Wilgotność względna\nZakres:\nw zakresie temperatur 10 °C do 20 °C 25 %rh do 95 %rh CMC 0,9 %rh\nw zakresie temperatur 20 °C do 40 °C 10 %rh do 95 %rh CMC 1,0 %rh\nw zakresie temperatur 40 °C do 60 °C 10 %rh do 90 %rh CMC 1,1 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/54\nLMEEiO/55 Higrometry\nTermohigrometry Wzorcowanie — Wilgotnosc wzgledna\nZakres:\nw zakresie temperatur 10 °C do 20 °C 25 %rh do 95 %rh CMC 0,9 %rh\nw zakresie temperatur 20 °C do 40 °C 10 %rh do 95 %rh CMC 1,0 %rh\nw zakresie temperatur 40 °C do 60 °C 10 %rh do 90 %rh CMC 1,1 %rh\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/54\nLMEEiO/55","search_en":"Hygrometers Thermohygrometers Calibration — Relative humidity Internal procedure; Direct method; At permanent location (S) and outside of it (P) Relative humidity Internal procedure Direct method At permanent location (S) and outside of it (P) temperature range 10 °C to 20 °C temperature range 20 °C to 40 °C temperature range 40 °C to 60 °C LMEEiO/54 LMEEiO/55","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":90,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"im Temperaturbereich 10 °C bis 20 °C","range":"25 %rh to 95 %rh","cmc":"0,9 %rh"},{"name":"im Temperaturbereich 20 °C bis 40 °C","range":"10 %rh to 95 %rh","cmc":"1,0 %rh"},{"name":"im Temperaturbereich 40 °C bis 60 °C","range":"10 %rh to 90 %rh","cmc":"1,1 %rh"}],"regulatory_area_de":"Relative Feuchte","search_de":"Hygrometer Thermohygrometer Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Relative Feuchte Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) im Temperaturbereich 10 °C bis 20 °C im Temperaturbereich 20 °C bis 40 °C im Temperaturbereich 40 °C bis 60 °C LMEEiO/54 LMEEiO/55","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Hygrometer\nThermohygrometer","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围 10 °C 至 20 °C","range":"25 %rh to 95 %rh","cmc":"0,9 %rh"},{"name":"温度范围 20 °C 至 40 °C","range":"10 %rh to 95 %rh","cmc":"1,0 %rh"},{"name":"温度范围 40 °C 至 60 °C","range":"10 %rh to 90 %rh","cmc":"1,1 %rh"}],"regulatory_area_zh":"相对湿度","search_zh":"湿度计 温湿度计 校准 — 相对湿度 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 相对湿度 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 温度范围 10 °C 至 20 °C 温度范围 20 °C 至 40 °C 温度范围 40 °C 至 60 °C LMEEiO/54 LMEEiO/55","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"湿度计\n温湿度计","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"v rozsahu teplot 10 °C až 20 °C","range":"25 %rh to 95 %rh","cmc":"0,9 %rh"},{"name":"v rozsahu teplot 20 °C až 40 °C","range":"10 %rh to 95 %rh","cmc":"1,0 %rh"},{"name":"v rozsahu teplot 40 °C až 60 °C","range":"10 %rh to 90 %rh","cmc":"1,1 %rh"}],"regulatory_area_cs":"Relativní vlhkost","search_cs":"Vlhkoměry Termohygrometry Kalibrace — Relativní vlhkost Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Relativní vlhkost Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) v rozsahu teplot 10 °C až 20 °C v rozsahu teplot 20 °C až 40 °C v rozsahu teplot 40 °C až 60 °C LMEEiO/54 LMEEiO/55","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Vlhkoměry\nTermohygrometry"},{"_id":"2b9e36d89d0fdc316a5af918","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Higrometry\nTermohigrometry","test_object_en":"Hygrometers\nThermohygrometers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"w zakresie temperatur 60 °C do 80 °C","range":"10 %rh do 50 %rh","cmc":"1,6 %rh"}],"parameters_en":[{"name":"temperature range 60 °C to 80 °C","range":"10 %rh to 50 %rh","cmc":"1,6 %rh"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nw zakresie temperatur 60 °C do 80 °C 10 %rh do 50 %rh CMC 1,6 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/54\nLMEEiO/55","norm_bases":["LMEEiO/54","LMEEiO/55"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Higrometry\nTermohigrometry Wzorcowanie — Wilgotność względna\nw zakresie temperatur 60 °C do 80 °C 10 %rh do 50 %rh CMC 1,6 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/54\nLMEEiO/55 Higrometry\nTermohigrometry Wzorcowanie — Wilgotnosc wzgledna\nw zakresie temperatur 60 °C do 80 °C 10 %rh do 50 %rh CMC 1,6 %rh\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/54\nLMEEiO/55","search_en":"Hygrometers Thermohygrometers Calibration — Relative humidity Internal procedure; Direct method; At permanent location (S) Relative humidity Internal procedure Direct method At permanent location (S) temperature range 60 °C to 80 °C LMEEiO/54 LMEEiO/55","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":91,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"im Temperaturbereich 60 °C bis 80 °C","range":"10 %rh to 50 %rh","cmc":"1,6 %rh"}],"regulatory_area_de":"Relative Feuchte","search_de":"Hygrometer Thermohygrometer Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Relative Feuchte Internes Verfahren Direktes Verfahren Am festen Standort (S) im Temperaturbereich 60 °C bis 80 °C LMEEiO/54 LMEEiO/55","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Hygrometer\nThermohygrometer","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围 60 °C 至 80 °C","range":"10 %rh to 50 %rh","cmc":"1,6 %rh"}],"regulatory_area_zh":"相对湿度","search_zh":"湿度计 温湿度计 校准 — 相对湿度 内部程序；直接法；在固定地点 (S) 相对湿度 内部程序 直接法 在固定地点 (S) 温度范围 60 °C 至 80 °C LMEEiO/54 LMEEiO/55","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"湿度计\n温湿度计","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"v rozsahu teplot 60 °C až 80 °C","range":"10 %rh to 50 %rh","cmc":"1,6 %rh"}],"regulatory_area_cs":"Relativní vlhkost","search_cs":"Vlhkoměry Termohygrometry Kalibrace — Relativní vlhkost Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Relativní vlhkost Vnitřní postup Přímá metoda Ve stálé lokalitě (S) v rozsahu teplot 60 °C až 80 °C LMEEiO/54 LMEEiO/55","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Vlhkoměry\nTermohygrometry"},{"_id":"901131fbcb465d1d1e3ae985","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Komory klimatyczne","test_object_en":"Climatic chambers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"w zakresie temperatur 10 °C do 20 °C","range":"10 %rh do 95 %rh","cmc":"2,6 %rh"},{"name":"w zakresie temperatur 20 °C do 40 °C","range":"10 %rh do 95 %rh","cmc":"2,6 %rh"},{"name":"w zakresie temperatur 40 °C do 60 °C","range":"10 %rh do 95 %rh","cmc":"2,7 %rh"},{"name":"w zakresie temperatur 60 °C do 80 °C","range":"10 %rh do 50 %rh","cmc":"2,7 %rh"}],"parameters_en":[{"name":"temperature range 10 °C to 20 °C","range":"10 %rh to 95 %rh","cmc":"2,6 %rh"},{"name":"temperature range 20 °C to 40 °C","range":"10 %rh to 95 %rh","cmc":"2,6 %rh"},{"name":"temperature range 40 °C to 60 °C","range":"10 %rh to 95 %rh","cmc":"2,7 %rh"},{"name":"temperature range 60 °C to 80 °C","range":"10 %rh to 50 %rh","cmc":"2,7 %rh"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nZakres:\nw zakresie temperatur 10 °C do 20 °C 10 %rh do 95 %rh CMC 2,6 %rh\nw zakresie temperatur 20 °C do 40 °C 10 %rh do 95 %rh CMC 2,6 %rh\nw zakresie temperatur 40 °C do 60 °C 10 %rh do 95 %rh CMC 2,7 %rh\nw zakresie temperatur 60 °C do 80 °C 10 %rh do 50 %rh CMC 2,7 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/54\nLMEEiO/55","norm_bases":["LMEEiO/54","LMEEiO/55"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Komory klimatyczne Wzorcowanie — Wilgotność względna\nZakres:\nw zakresie temperatur 10 °C do 20 °C 10 %rh do 95 %rh CMC 2,6 %rh\nw zakresie temperatur 20 °C do 40 °C 10 %rh do 95 %rh CMC 2,6 %rh\nw zakresie temperatur 40 °C do 60 °C 10 %rh do 95 %rh CMC 2,7 %rh\nw zakresie temperatur 60 °C do 80 °C 10 %rh do 50 %rh CMC 2,7 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/54\nLMEEiO/55 Komory klimatyczne Wzorcowanie — Wilgotnosc wzgledna\nZakres:\nw zakresie temperatur 10 °C do 20 °C 10 %rh do 95 %rh CMC 2,6 %rh\nw zakresie temperatur 20 °C do 40 °C 10 %rh do 95 %rh CMC 2,6 %rh\nw zakresie temperatur 40 °C do 60 °C 10 %rh do 95 %rh CMC 2,7 %rh\nw zakresie temperatur 60 °C do 80 °C 10 %rh do 50 %rh CMC 2,7 %rh\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/54\nLMEEiO/55","search_en":"Climatic chambers Calibration — Relative humidity Internal procedure; Direct method; At permanent location (S) and outside of it (P) Relative humidity Internal procedure Direct method At permanent location (S) and outside of it (P) temperature range 10 °C to 20 °C temperature range 20 °C to 40 °C temperature range 40 °C to 60 °C temperature range 60 °C to 80 °C LMEEiO/54 LMEEiO/55","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":92,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"im Temperaturbereich 10 °C bis 20 °C","range":"10 %rh to 95 %rh","cmc":"2,6 %rh"},{"name":"im Temperaturbereich 20 °C bis 40 °C","range":"10 %rh to 95 %rh","cmc":"2,6 %rh"},{"name":"im Temperaturbereich 40 °C bis 60 °C","range":"10 %rh to 95 %rh","cmc":"2,7 %rh"},{"name":"im Temperaturbereich 60 °C bis 80 °C","range":"10 %rh to 50 %rh","cmc":"2,7 %rh"}],"regulatory_area_de":"Relative Feuchte","search_de":"Klimakammern Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Relative Feuchte Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) im Temperaturbereich 10 °C bis 20 °C im Temperaturbereich 20 °C bis 40 °C im Temperaturbereich 40 °C bis 60 °C im Temperaturbereich 60 °C bis 80 °C LMEEiO/54 LMEEiO/55","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Klimakammern","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围 10 °C 至 20 °C","range":"10 %rh to 95 %rh","cmc":"2,6 %rh"},{"name":"温度范围 20 °C 至 40 °C","range":"10 %rh to 95 %rh","cmc":"2,6 %rh"},{"name":"温度范围 40 °C 至 60 °C","range":"10 %rh to 95 %rh","cmc":"2,7 %rh"},{"name":"温度范围 60 °C 至 80 °C","range":"10 %rh to 50 %rh","cmc":"2,7 %rh"}],"regulatory_area_zh":"相对湿度","search_zh":"气候箱 校准 — 相对湿度 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 相对湿度 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 温度范围 10 °C 至 20 °C 温度范围 20 °C 至 40 °C 温度范围 40 °C 至 60 °C 温度范围 60 °C 至 80 °C LMEEiO/54 LMEEiO/55","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"气候箱","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"v rozsahu teplot 10 °C až 20 °C","range":"10 %rh to 95 %rh","cmc":"2,6 %rh"},{"name":"v rozsahu teplot 20 °C až 40 °C","range":"10 %rh to 95 %rh","cmc":"2,6 %rh"},{"name":"v rozsahu teplot 40 °C až 60 °C","range":"10 %rh to 95 %rh","cmc":"2,7 %rh"},{"name":"v rozsahu teplot 60 °C až 80 °C","range":"10 %rh to 50 %rh","cmc":"2,7 %rh"}],"regulatory_area_cs":"Relativní vlhkost","search_cs":"Klimatické komory Kalibrace — Relativní vlhkost Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Relativní vlhkost Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) v rozsahu teplot 10 °C až 20 °C v rozsahu teplot 20 °C až 40 °C v rozsahu teplot 40 °C až 60 °C v rozsahu teplot 60 °C až 80 °C LMEEiO/54 LMEEiO/55","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Klimatické komory"},{"_id":"7da12ba76798aefa301b9bdd","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki mocy (poziomu mocy) promieniowania optycznego\nZestawy do pomiaru tłumienności\nAnalizatory widma promieniowania optycznego\nMierniki długości fali\nMierniki tłumienności odbicia\n- moc (poziom mocy) promieniowania optycznego","test_object_en":"Optical power (power level) meters\nAttenuation measurement sets\nOptical spectrum analysers\nWavelength meters\nReturn loss meters\n- optical radiation power (power level)","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 850 nm, 1260 nm do 1360 nm, 1480 nm do 1680 nm","range":"100 pW do 150 µW","cmc":"1,26 %"},{"name":"długość fali 850 nm, 1260 nm do 1360 nm, 1480 nm do 1680 nm","range":"-70 dBm do -8 dBm","cmc":"0,054 dB"}],"parameters_en":[{"name":"wavelength 850 nm, 1260 nm to 1360 nm, 1480 nm to 1680 nm","range":"100 pW to 150 µW","cmc":"1,26 %"},{"name":"wavelength 850 nm, 1260 nm to 1360 nm, 1480 nm to 1680 nm","range":"-70 dBm to -8 dBm","cmc":"0,054 dB"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 850 nm, 1260 nm do 1360 nm, 1480 nm do 1680 nm 100 pW do 150 µW CMC 1,26 %\ndługość fali 850 nm, 1260 nm do 1360 nm, 1480 nm do 1680 nm -70 dBm do -8 dBm CMC 0,054 dB\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\nw oparciu o\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016","norm_bases":["LMEEiO/21","LMEEiO/22","LMEEiO/24","LMEEiO/26","LMEEiO/ 27","LMEEiO/29","LMEEiO/36","PN-EN IEC 61315:2019-10","IEC 62129-1:2016"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy (poziomu mocy) promieniowania optycznego\nZestawy do pomiaru tłumienności\nAnalizatory widma promieniowania optycznego\nMierniki długości fali\nMierniki tłumienności odbicia\n- moc (poziom mocy) promieniowania optycznego Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 850 nm, 1260 nm do 1360 nm, 1480 nm do 1680 nm 100 pW do 150 µW CMC 1,26 %\ndługość fali 850 nm, 1260 nm do 1360 nm, 1480 nm do 1680 nm -70 dBm do -8 dBm CMC 0,054 dB\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\nw oparciu o\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016 Mierniki mocy (poziomu mocy) promieniowania optycznego\nZestawy do pomiaru tlumiennosci\nAnalizatory widma promieniowania optycznego\nMierniki dlugosci fali\nMierniki tlumiennosci odbicia\n- moc (poziom mocy) promieniowania optycznego Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 850 nm, 1260 nm do 1360 nm, 1480 nm do 1680 nm 100 pW do 150 µW CMC 1,26 %\ndlugosc fali 850 nm, 1260 nm do 1360 nm, 1480 nm do 1680 nm -70 dBm do -8 dBm CMC 0,054 dB\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\nw oparciu o\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016","search_en":"Optical power (power level) meters Attenuation measurement sets Optical spectrum analysers Wavelength meters Return loss meters - optical radiation power (power level) Calibration — Optoelectronic quantities Internal procedure; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure At permanent location (S) and outside of it (P) wavelength 850 nm, 1260 nm to 1360 nm, 1480 nm to 1680 nm wavelength 850 nm, 1260 nm to 1360 nm, 1480 nm to 1680 nm LMEEiO/21, LMEEiO/22, LMEEiO/24, LMEEiO/26, LMEEiO/ 27 LMEEiO/29, LMEEiO/36 based on PN-EN IEC 61315:2019-10 IEC 62129-1:2016","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":93,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\nbased on\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 850 nm, 1260 nm bis 1360 nm, 1480 nm bis 1680 nm","range":"100 pW to 150 µW","cmc":"1,26 %"},{"name":"Wellenlänge 850 nm, 1260 nm bis 1360 nm, 1480 nm bis 1680 nm","range":"-70 dBm to -8 dBm","cmc":"0,054 dB"}],"reference_de":"LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\nauf Grundlage von\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Leistungs(pegel)messgeräte Dämpfungsmesssätze Optische Spektrumanalysatoren Wellenlängenmessgeräte Rückflussdämpfungsmessgeräte - Leistung (Leistungspegel) der optischen Strahlung Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Am festen Standort (S) und außerhalb (P) Wellenlänge 850 nm, 1260 nm bis 1360 nm, 1480 nm bis 1680 nm Wellenlänge 850 nm, 1260 nm bis 1360 nm, 1480 nm bis 1680 nm LMEEiO/21, LMEEiO/22, LMEEiO/24, LMEEiO/26, LMEEiO/ 27 LMEEiO/29, LMEEiO/36 auf Grundlage von PN-EN IEC 61315:2019-10 IEC 62129-1:2016","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Leistungs(pegel)messgeräte\nDämpfungsmesssätze\nOptische Spektrumanalysatoren\nWellenlängenmessgeräte\nRückflussdämpfungsmessgeräte\n- Leistung (Leistungspegel) der optischen Strahlung","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 850 nm, 1260 nm 至 1360 nm, 1480 nm 至 1680 nm","range":"100 pW to 150 µW","cmc":"1,26 %"},{"name":"波长 850 nm, 1260 nm 至 1360 nm, 1480 nm 至 1680 nm","range":"-70 dBm to -8 dBm","cmc":"0,054 dB"}],"reference_zh":"LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\n依据\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016","regulatory_area_zh":"光电量","search_zh":"光功率（功率电平）计 衰减测量装置 光谱分析仪 波长计 回波损耗测量仪 - 光辐射功率（功率电平） 校准 — 光电量 内部程序；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 在固定地点 (S) 及固定地点以外 (P) 波长 850 nm, 1260 nm 至 1360 nm, 1480 nm 至 1680 nm 波长 850 nm, 1260 nm 至 1360 nm, 1480 nm 至 1680 nm LMEEiO/21, LMEEiO/22, LMEEiO/24, LMEEiO/26, LMEEiO/ 27 LMEEiO/29, LMEEiO/36 依据 PN-EN IEC 61315:2019-10 IEC 62129-1:2016","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光功率（功率电平）计\n衰减测量装置\n光谱分析仪\n波长计\n回波损耗测量仪\n- 光辐射功率（功率电平）","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 850 nm, 1260 nm až 1360 nm, 1480 nm až 1680 nm","range":"100 pW to 150 µW","cmc":"1,26 %"},{"name":"vlnová délka 850 nm, 1260 nm až 1360 nm, 1480 nm až 1680 nm","range":"-70 dBm to -8 dBm","cmc":"0,054 dB"}],"reference_cs":"LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\nna základě\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Měřiče výkonu (úrovně výkonu) optického záření Soupravy pro měření útlumu Analyzátory optického spektra Měřiče vlnové délky Měřiče útlumu odrazu - výkon (úroveň výkonu) optického záření Kalibrace — Optoelektronické veličiny Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) vlnová délka 850 nm, 1260 nm až 1360 nm, 1480 nm až 1680 nm vlnová délka 850 nm, 1260 nm až 1360 nm, 1480 nm až 1680 nm LMEEiO/21, LMEEiO/22, LMEEiO/24, LMEEiO/26, LMEEiO/ 27 LMEEiO/29, LMEEiO/36 na základě PN-EN IEC 61315:2019-10 IEC 62129-1:2016","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče výkonu (úrovně výkonu) optického záření\nSoupravy pro měření útlumu\nAnalyzátory optického spektra\nMěřiče vlnové délky\nMěřiče útlumu odrazu\n- výkon (úroveň výkonu) optického záření"},{"_id":"608e7a3d54c9f3eb8176fda9","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Źródła promieniowania optycznego\nZestawy do pomiaru tłumienności\nMierniki tłumienności odbicia (reflektancji)\nReflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\nReflektometry światłowodowe wielomodowe\nNadajniki zawarte w analizatorach/testerach PDH/SDH\n- moc (poziom mocy) promieniowania optycznego","test_object_en":"Optical radiation sources\nAttenuation measurement sets\nReturn loss (reflectance) meters\nOptical time-domain reflectometers (OTDR)\nSingle-mode optical time-domain reflectometers\nMultimode optical time-domain reflectometers\nTransmitters included in PDH/SDH analysers/testers\n- optical radiation power (power level)","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 350 nm do 400 nm","range":"100 pW do 500 mW","cmc":"7%"},{"name":"długość fali 350 nm do 400 nm","range":"-70 dBm do 25 dBm","cmc":"0,3 dB"}],"parameters_en":[{"name":"wavelength 350 nm to 400 nm","range":"100 pW to 500 mW","cmc":"7%"},{"name":"wavelength 350 nm to 400 nm","range":"-70 dBm to 25 dBm","cmc":"0,3 dB"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 350 nm do 400 nm 100 pW do 500 mW CMC 7%\ndługość fali 350 nm do 400 nm -70 dBm do 25 dBm CMC 0,3 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\nw oparciu o\nPN-EN-61280-1-1:2013-10","norm_bases":["LMEEiO/21","LMEEiO/22","LMEEiO/24","LMEEiO/26","LMEEiO/27","PN-EN-61280-1-1:2013-10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Źródła promieniowania optycznego\nZestawy do pomiaru tłumienności\nMierniki tłumienności odbicia (reflektancji)\nReflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\nReflektometry światłowodowe wielomodowe\nNadajniki zawarte w analizatorach/testerach PDH/SDH\n- moc (poziom mocy) promieniowania optycznego Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 350 nm do 400 nm 100 pW do 500 mW CMC 7%\ndługość fali 350 nm do 400 nm -70 dBm do 25 dBm CMC 0,3 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\nw oparciu o\nPN-EN-61280-1-1:2013-10 Zrodla promieniowania optycznego\nZestawy do pomiaru tlumiennosci\nMierniki tlumiennosci odbicia (reflektancji)\nReflektometry optyczne (OTDR)\nReflektometry swiatlowodowe jednomodowe\nReflektometry swiatlowodowe wielomodowe\nNadajniki zawarte w analizatorach/testerach PDH/SDH\n- moc (poziom mocy) promieniowania optycznego Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 350 nm do 400 nm 100 pW do 500 mW CMC 7%\ndlugosc fali 350 nm do 400 nm -70 dBm do 25 dBm CMC 0,3 dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\nw oparciu o\nPN-EN-61280-1-1:2013-10","search_en":"Optical radiation sources Attenuation measurement sets Return loss (reflectance) meters Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers Multimode optical time-domain reflectometers Transmitters included in PDH/SDH analysers/testers - optical radiation power (power level) Calibration — Optoelectronic quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Direct method At permanent location (S) and outside of it (P) wavelength 350 nm to 400 nm wavelength 350 nm to 400 nm LMEEiO/21, LMEEiO/22 LMEEiO/24, LMEEiO/26, LMEEiO/27 based on PN-EN-61280-1-1:2013-10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":94,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\nbased on\nPN-EN-61280-1-1:2013-10","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 350 nm bis 400 nm","range":"100 pW to 500 mW","cmc":"7%"},{"name":"Wellenlänge 350 nm bis 400 nm","range":"-70 dBm to 25 dBm","cmc":"0,3 dB"}],"reference_de":"LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\nauf Grundlage von\nPN-EN-61280-1-1:2013-10","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Strahlungsquellen Dämpfungsmesssätze Rückflussdämpfungsmessgeräte (Reflexionsgrad) Optische Reflektometer (OTDR) Singlemode-Lichtwellenleiter-Reflektometer (OTDR) Multimode-Lichtwellenleiter-Reflektometer (OTDR) Sender in PDH/SDH-Analysatoren/-Testern - Leistung (Leistungspegel) der optischen Strahlung Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) Wellenlänge 350 nm bis 400 nm Wellenlänge 350 nm bis 400 nm LMEEiO/21, LMEEiO/22 LMEEiO/24, LMEEiO/26, LMEEiO/27 auf Grundlage von PN-EN-61280-1-1:2013-10","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Strahlungsquellen\nDämpfungsmesssätze\nRückflussdämpfungsmessgeräte (Reflexionsgrad)\nOptische Reflektometer (OTDR)\nSinglemode-Lichtwellenleiter-Reflektometer (OTDR)\nMultimode-Lichtwellenleiter-Reflektometer (OTDR)\nSender in PDH/SDH-Analysatoren/-Testern\n- Leistung (Leistungspegel) der optischen Strahlung","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 350 nm 至 400 nm","range":"100 pW to 500 mW","cmc":"7%"},{"name":"波长 350 nm 至 400 nm","range":"-70 dBm to 25 dBm","cmc":"0,3 dB"}],"reference_zh":"LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\n依据\nPN-EN-61280-1-1:2013-10","regulatory_area_zh":"光电量","search_zh":"光辐射源 衰减测量装置 回波损耗（反射率）测量仪 光时域反射仪（OTDR） 单模光时域反射仪 多模光时域反射仪 PDH/SDH 分析仪/测试仪中的发射机 - 光辐射功率（功率电平） 校准 — 光电量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 波长 350 nm 至 400 nm 波长 350 nm 至 400 nm LMEEiO/21, LMEEiO/22 LMEEiO/24, LMEEiO/26, LMEEiO/27 依据 PN-EN-61280-1-1:2013-10","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光辐射源\n衰减测量装置\n回波损耗（反射率）测量仪\n光时域反射仪（OTDR）\n单模光时域反射仪\n多模光时域反射仪\nPDH/SDH 分析仪/测试仪中的发射机\n- 光辐射功率（功率电平）","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 350 nm až 400 nm","range":"100 pW to 500 mW","cmc":"7%"},{"name":"vlnová délka 350 nm až 400 nm","range":"-70 dBm to 25 dBm","cmc":"0,3 dB"}],"reference_cs":"LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\nna základě\nPN-EN-61280-1-1:2013-10","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Zdroje optického záření Soupravy pro měření útlumu Měřiče útlumu odrazu (reflektance) Optické reflektometry (OTDR) Jednovidové optické reflektometry Mnohovidové optické reflektometry Vysílače obsažené v analyzátorech/testerech PDH/SDH - výkon (úroveň výkonu) optického záření Kalibrace — Optoelektronické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) vlnová délka 350 nm až 400 nm vlnová délka 350 nm až 400 nm LMEEiO/21, LMEEiO/22 LMEEiO/24, LMEEiO/26, LMEEiO/27 na základě PN-EN-61280-1-1:2013-10","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Zdroje optického záření\nSoupravy pro měření útlumu\nMěřiče útlumu odrazu (reflektance)\nOptické reflektometry (OTDR)\nJednovidové optické reflektometry\nMnohovidové optické reflektometry\nVysílače obsažené v analyzátorech/testerech PDH/SDH\n- výkon (úroveň výkonu) optického záření"},{"_id":"f1253f82504f7f69e72b1168","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Źródła promieniowania optycznego\nZestawy do pomiaru tłumienności\nMierniki tłumienności odbicia (reflektancji)\nReflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\nReflektometry światłowodowe wielomodowe\nNadajniki zawarte w analizatorach/testerach PDH/SDH\n- moc (poziom mocy) promieniowania optycznego","test_object_en":"Optical radiation sources\nAttenuation measurement sets\nReturn loss (reflectance) meters\nOptical time-domain reflectometers (OTDR)\nSingle-mode optical time-domain reflectometers\nMultimode optical time-domain reflectometers\nTransmitters included in PDH/SDH analysers/testers\n- optical radiation power (power level)","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 450 nm do 1700 nm","range":"100 pW do 500 mW","cmc":"4,0 %"},{"name":"długość fali 450 nm do 1700 nm","range":"-70 dBm do 25 dBm","cmc":"0,17 dB"}],"parameters_en":[{"name":"wavelength 450 nm to 1700 nm","range":"100 pW to 500 mW","cmc":"4,0 %"},{"name":"wavelength 450 nm to 1700 nm","range":"-70 dBm to 25 dBm","cmc":"0,17 dB"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 450 nm do 1700 nm 100 pW do 500 mW CMC 4,0 %\ndługość fali 450 nm do 1700 nm -70 dBm do 25 dBm CMC 0,17 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\nw oparciu o\nPN-EN-61280-1-1:2013-10","norm_bases":["LMEEiO/21","LMEEiO/22","LMEEiO/24","LMEEiO/26","LMEEiO/27","PN-EN-61280-1-1:2013-10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Źródła promieniowania optycznego\nZestawy do pomiaru tłumienności\nMierniki tłumienności odbicia (reflektancji)\nReflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\nReflektometry światłowodowe wielomodowe\nNadajniki zawarte w analizatorach/testerach PDH/SDH\n- moc (poziom mocy) promieniowania optycznego Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 450 nm do 1700 nm 100 pW do 500 mW CMC 4,0 %\ndługość fali 450 nm do 1700 nm -70 dBm do 25 dBm CMC 0,17 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\nw oparciu o\nPN-EN-61280-1-1:2013-10 Zrodla promieniowania optycznego\nZestawy do pomiaru tlumiennosci\nMierniki tlumiennosci odbicia (reflektancji)\nReflektometry optyczne (OTDR)\nReflektometry swiatlowodowe jednomodowe\nReflektometry swiatlowodowe wielomodowe\nNadajniki zawarte w analizatorach/testerach PDH/SDH\n- moc (poziom mocy) promieniowania optycznego Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 450 nm do 1700 nm 100 pW do 500 mW CMC 4,0 %\ndlugosc fali 450 nm do 1700 nm -70 dBm do 25 dBm CMC 0,17 dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\nw oparciu o\nPN-EN-61280-1-1:2013-10","search_en":"Optical radiation sources Attenuation measurement sets Return loss (reflectance) meters Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers Multimode optical time-domain reflectometers Transmitters included in PDH/SDH analysers/testers - optical radiation power (power level) Calibration — Optoelectronic quantities Internal procedure; Direct method; At permanent location (S) Optoelectronic quantities Internal procedure Direct method At permanent location (S) wavelength 450 nm to 1700 nm wavelength 450 nm to 1700 nm LMEEiO/21, LMEEiO/22 LMEEiO/24, LMEEiO/26, LMEEiO/27 based on PN-EN-61280-1-1:2013-10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":95,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\nbased on\nPN-EN-61280-1-1:2013-10","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 450 nm bis 1700 nm","range":"100 pW to 500 mW","cmc":"4,0 %"},{"name":"Wellenlänge 450 nm bis 1700 nm","range":"-70 dBm to 25 dBm","cmc":"0,17 dB"}],"reference_de":"LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\nauf Grundlage von\nPN-EN-61280-1-1:2013-10","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Strahlungsquellen Dämpfungsmesssätze Rückflussdämpfungsmessgeräte (Reflexionsgrad) Optische Reflektometer (OTDR) Singlemode-Lichtwellenleiter-Reflektometer (OTDR) Multimode-Lichtwellenleiter-Reflektometer (OTDR) Sender in PDH/SDH-Analysatoren/-Testern - Leistung (Leistungspegel) der optischen Strahlung Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Optoelektronische Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) Wellenlänge 450 nm bis 1700 nm Wellenlänge 450 nm bis 1700 nm LMEEiO/21, LMEEiO/22 LMEEiO/24, LMEEiO/26, LMEEiO/27 auf Grundlage von PN-EN-61280-1-1:2013-10","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Optische Strahlungsquellen\nDämpfungsmesssätze\nRückflussdämpfungsmessgeräte (Reflexionsgrad)\nOptische Reflektometer (OTDR)\nSinglemode-Lichtwellenleiter-Reflektometer (OTDR)\nMultimode-Lichtwellenleiter-Reflektometer (OTDR)\nSender in PDH/SDH-Analysatoren/-Testern\n- Leistung (Leistungspegel) der optischen Strahlung","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 450 nm 至 1700 nm","range":"100 pW to 500 mW","cmc":"4,0 %"},{"name":"波长 450 nm 至 1700 nm","range":"-70 dBm to 25 dBm","cmc":"0,17 dB"}],"reference_zh":"LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\n依据\nPN-EN-61280-1-1:2013-10","regulatory_area_zh":"光电量","search_zh":"光辐射源 衰减测量装置 回波损耗（反射率）测量仪 光时域反射仪（OTDR） 单模光时域反射仪 多模光时域反射仪 PDH/SDH 分析仪/测试仪中的发射机 - 光辐射功率（功率电平） 校准 — 光电量 内部程序；直接法；在固定地点 (S) 光电量 内部程序 直接法 在固定地点 (S) 波长 450 nm 至 1700 nm 波长 450 nm 至 1700 nm LMEEiO/21, LMEEiO/22 LMEEiO/24, LMEEiO/26, LMEEiO/27 依据 PN-EN-61280-1-1:2013-10","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"光辐射源\n衰减测量装置\n回波损耗（反射率）测量仪\n光时域反射仪（OTDR）\n单模光时域反射仪\n多模光时域反射仪\nPDH/SDH 分析仪/测试仪中的发射机\n- 光辐射功率（功率电平）","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 450 nm až 1700 nm","range":"100 pW to 500 mW","cmc":"4,0 %"},{"name":"vlnová délka 450 nm až 1700 nm","range":"-70 dBm to 25 dBm","cmc":"0,17 dB"}],"reference_cs":"LMEEiO/21, LMEEiO/22\nLMEEiO/24, LMEEiO/26,\nLMEEiO/27\nna základě\nPN-EN-61280-1-1:2013-10","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Zdroje optického záření Soupravy pro měření útlumu Měřiče útlumu odrazu (reflektance) Optické reflektometry (OTDR) Jednovidové optické reflektometry Mnohovidové optické reflektometry Vysílače obsažené v analyzátorech/testerech PDH/SDH - výkon (úroveň výkonu) optického záření Kalibrace — Optoelektronické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Optoelektronické veličiny Vnitřní postup Přímá metoda Ve stálé lokalitě (S) vlnová délka 450 nm až 1700 nm vlnová délka 450 nm až 1700 nm LMEEiO/21, LMEEiO/22 LMEEiO/24, LMEEiO/26, LMEEiO/27 na základě PN-EN-61280-1-1:2013-10","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Zdroje optického záření\nSoupravy pro měření útlumu\nMěřiče útlumu odrazu (reflektance)\nOptické reflektometry (OTDR)\nJednovidové optické reflektometry\nMnohovidové optické reflektometry\nVysílače obsažené v analyzátorech/testerech PDH/SDH\n- výkon (úroveň výkonu) optického záření"},{"_id":"d80e6f9cd873550528106dcb","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki mocy (poziomu mocy) promieniowania optycznego\nZestawy do pomiaru tłumienności\nAnalizatory widma promieniowania optycznego\nMierniki długości fali\nMierniki tłumienności odbicia\n- nieliniowość skali przy pomiarze mocy (poziomu mocy) promieniowania optycznego","test_object_en":"Optical power (power level) meters\nAttenuation measurement sets\nOptical spectrum analysers\nWavelength meters\nReturn loss meters\n- scale non-linearity in optical radiation power (power level) measurement","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 850 nm 1260 nm do 1360 nm 1480 nm do 1680 nm","range":"100 pW do 1 mW","cmc":"0,15%"},{"name":"długość fali 850 nm 1260 nm do 1360 nm 1480 nm do 1680 nm","range":"-70 dBm do 0 dBm","cmc":"0,007 dB"}],"parameters_en":[{"name":"wavelength 850 nm 1260 nm to 1360 nm 1480 nm to 1680 nm","range":"100 pW to 1 mW","cmc":"0,15%"},{"name":"wavelength 850 nm 1260 nm to 1360 nm 1480 nm to 1680 nm","range":"-70 dBm to 0 dBm","cmc":"0,007 dB"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 850 nm 1260 nm do 1360 nm 1480 nm do 1680 nm 100 pW do 1 mW CMC 0,15%\ndługość fali 850 nm 1260 nm do 1360 nm 1480 nm do 1680 nm -70 dBm do 0 dBm CMC 0,007 dB\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\nw oparciu o\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016","norm_bases":["LMEEiO/21","LMEEiO/22","LMEEiO/24","LMEEiO/26","LMEEiO/ 27","LMEEiO/29","LMEEiO/36","PN-EN IEC 61315:2019-10","IEC 62129-1:2016"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy (poziomu mocy) promieniowania optycznego\nZestawy do pomiaru tłumienności\nAnalizatory widma promieniowania optycznego\nMierniki długości fali\nMierniki tłumienności odbicia\n- nieliniowość skali przy pomiarze mocy (poziomu mocy) promieniowania optycznego Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 850 nm 1260 nm do 1360 nm 1480 nm do 1680 nm 100 pW do 1 mW CMC 0,15%\ndługość fali 850 nm 1260 nm do 1360 nm 1480 nm do 1680 nm -70 dBm do 0 dBm CMC 0,007 dB\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\nw oparciu o\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016 Mierniki mocy (poziomu mocy) promieniowania optycznego\nZestawy do pomiaru tlumiennosci\nAnalizatory widma promieniowania optycznego\nMierniki dlugosci fali\nMierniki tlumiennosci odbicia\n- nieliniowosc skali przy pomiarze mocy (poziomu mocy) promieniowania optycznego Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 850 nm 1260 nm do 1360 nm 1480 nm do 1680 nm 100 pW do 1 mW CMC 0,15%\ndlugosc fali 850 nm 1260 nm do 1360 nm 1480 nm do 1680 nm -70 dBm do 0 dBm CMC 0,007 dB\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\nw oparciu o\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016","search_en":"Optical power (power level) meters Attenuation measurement sets Optical spectrum analysers Wavelength meters Return loss meters - scale non-linearity in optical radiation power (power level) measurement Calibration — Optoelectronic quantities Internal procedure; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure At permanent location (S) and outside of it (P) wavelength 850 nm 1260 nm to 1360 nm 1480 nm to 1680 nm wavelength 850 nm 1260 nm to 1360 nm 1480 nm to 1680 nm LMEEiO/21, LMEEiO/22, LMEEiO/24, LMEEiO/26, LMEEiO/ 27 LMEEiO/29, LMEEiO/36 based on PN-EN IEC 61315:2019-10 IEC 62129-1:2016","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":96,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\nbased on\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 850 nm 1260 nm bis 1360 nm 1480 nm bis 1680 nm","range":"100 pW to 1 mW","cmc":"0,15%"},{"name":"Wellenlänge 850 nm 1260 nm bis 1360 nm 1480 nm bis 1680 nm","range":"-70 dBm to 0 dBm","cmc":"0,007 dB"}],"reference_de":"LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\nauf Grundlage von\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Leistungs(pegel)messgeräte Dämpfungsmesssätze Optische Spektrumanalysatoren Wellenlängenmessgeräte Rückflussdämpfungsmessgeräte - Skalennichtlinearität bei der Messung der Leistung (des Leistungspegels) optischer Strahlung Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Am festen Standort (S) und außerhalb (P) Wellenlänge 850 nm 1260 nm bis 1360 nm 1480 nm bis 1680 nm Wellenlänge 850 nm 1260 nm bis 1360 nm 1480 nm bis 1680 nm LMEEiO/21, LMEEiO/22, LMEEiO/24, LMEEiO/26, LMEEiO/ 27 LMEEiO/29, LMEEiO/36 auf Grundlage von PN-EN IEC 61315:2019-10 IEC 62129-1:2016","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Leistungs(pegel)messgeräte\nDämpfungsmesssätze\nOptische Spektrumanalysatoren\nWellenlängenmessgeräte\nRückflussdämpfungsmessgeräte\n- Skalennichtlinearität bei der Messung der Leistung (des Leistungspegels) optischer Strahlung","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 850 nm 1260 nm 至 1360 nm 1480 nm 至 1680 nm","range":"100 pW to 1 mW","cmc":"0,15%"},{"name":"波长 850 nm 1260 nm 至 1360 nm 1480 nm 至 1680 nm","range":"-70 dBm to 0 dBm","cmc":"0,007 dB"}],"reference_zh":"LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\n依据\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016","regulatory_area_zh":"光电量","search_zh":"光功率（功率电平）计 衰减测量装置 光谱分析仪 波长计 回波损耗测量仪 - 光辐射功率（功率电平）测量的标度非线性 校准 — 光电量 内部程序；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 在固定地点 (S) 及固定地点以外 (P) 波长 850 nm 1260 nm 至 1360 nm 1480 nm 至 1680 nm 波长 850 nm 1260 nm 至 1360 nm 1480 nm 至 1680 nm LMEEiO/21, LMEEiO/22, LMEEiO/24, LMEEiO/26, LMEEiO/ 27 LMEEiO/29, LMEEiO/36 依据 PN-EN IEC 61315:2019-10 IEC 62129-1:2016","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光功率（功率电平）计\n衰减测量装置\n光谱分析仪\n波长计\n回波损耗测量仪\n- 光辐射功率（功率电平）测量的标度非线性","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 850 nm 1260 nm až 1360 nm 1480 nm až 1680 nm","range":"100 pW to 1 mW","cmc":"0,15%"},{"name":"vlnová délka 850 nm 1260 nm až 1360 nm 1480 nm až 1680 nm","range":"-70 dBm to 0 dBm","cmc":"0,007 dB"}],"reference_cs":"LMEEiO/21, LMEEiO/22,\nLMEEiO/24, LMEEiO/26,\nLMEEiO/ 27 LMEEiO/29,\nLMEEiO/36\nna základě\nPN-EN IEC 61315:2019-10\nIEC 62129-1:2016","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Měřiče výkonu (úrovně výkonu) optického záření Soupravy pro měření útlumu Analyzátory optického spektra Měřiče vlnové délky Měřiče útlumu odrazu - nelinearita stupnice při měření výkonu (úrovně výkonu) optického záření Kalibrace — Optoelektronické veličiny Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) vlnová délka 850 nm 1260 nm až 1360 nm 1480 nm až 1680 nm vlnová délka 850 nm 1260 nm až 1360 nm 1480 nm až 1680 nm LMEEiO/21, LMEEiO/22, LMEEiO/24, LMEEiO/26, LMEEiO/ 27 LMEEiO/29, LMEEiO/36 na základě PN-EN IEC 61315:2019-10 IEC 62129-1:2016","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče výkonu (úrovně výkonu) optického záření\nSoupravy pro měření útlumu\nAnalyzátory optického spektra\nMěřiče vlnové délky\nMěřiče útlumu odrazu\n- nelinearita stupnice při měření výkonu (úrovně výkonu) optického záření"},{"_id":"c6b7aeb4cce1e620f48144f0","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Reflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\n- długość optyczna światłowodu","test_object_en":"Optical time-domain reflectometers (OTDR)\nSingle-mode optical time-domain reflectometers\n- optical fibre length","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 1310 nm","range":"do 25 km","cmc":"0,3 m"},{"name":"długość fali 1383 nm","range":"do 25 km","cmc":"0,3 m"},{"name":"długość fali 1490 nm","range":"do 25 km","cmc":"0,3 m"},{"name":"długość fali 1550 nm","range":"do 25 km","cmc":"0,3 m"},{"name":"długość fali 1625 nm","range":"do 25 km","cmc":"0,3 m"},{"name":"długość fali 1650 nm","range":"do 25 km","cmc":"0,3 m"}],"parameters_en":[{"name":"wavelength 1310 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"wavelength 1383 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"wavelength 1490 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"wavelength 1550 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"wavelength 1625 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"wavelength 1650 nm","range":"up to 25 km","cmc":"0,3 m"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1310 nm do 25 km CMC 0,3 m\ndługość fali 1383 nm do 25 km CMC 0,3 m\ndługość fali 1490 nm do 25 km CMC 0,3 m\ndługość fali 1550 nm do 25 km CMC 0,3 m\ndługość fali 1625 nm do 25 km CMC 0,3 m\ndługość fali 1650 nm do 25 km CMC 0,3 m\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21 w oparciu o PN-EN 61746-1:2011","norm_bases":["LMEEiO/21","PN-EN 61746-1:2011"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Reflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\n- długość optyczna światłowodu Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1310 nm do 25 km CMC 0,3 m\ndługość fali 1383 nm do 25 km CMC 0,3 m\ndługość fali 1490 nm do 25 km CMC 0,3 m\ndługość fali 1550 nm do 25 km CMC 0,3 m\ndługość fali 1625 nm do 25 km CMC 0,3 m\ndługość fali 1650 nm do 25 km CMC 0,3 m\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21 w oparciu o PN-EN 61746-1:2011 Reflektometry optyczne (OTDR)\nReflektometry swiatlowodowe jednomodowe\n- dlugosc optyczna swiatlowodu Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 1310 nm do 25 km CMC 0,3 m\ndlugosc fali 1383 nm do 25 km CMC 0,3 m\ndlugosc fali 1490 nm do 25 km CMC 0,3 m\ndlugosc fali 1550 nm do 25 km CMC 0,3 m\ndlugosc fali 1625 nm do 25 km CMC 0,3 m\ndlugosc fali 1650 nm do 25 km CMC 0,3 m\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21 w oparciu o PN-EN 61746-1:2011","search_en":"Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers - optical fibre length Calibration — Optoelectronic quantities Internal procedure; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure At permanent location (S) and outside of it (P) wavelength 1310 nm wavelength 1383 nm wavelength 1490 nm wavelength 1550 nm wavelength 1625 nm wavelength 1650 nm LMEEiO/21 based on PN-EN 61746-1:2011","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":97,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/21 based on PN-EN 61746-1:2011","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 1310 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"Wellenlänge 1383 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"Wellenlänge 1490 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"Wellenlänge 1550 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"Wellenlänge 1625 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"Wellenlänge 1650 nm","range":"up to 25 km","cmc":"0,3 m"}],"reference_de":"LMEEiO/21 auf Grundlage von PN-EN 61746-1:2011","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Reflektometer (OTDR) Singlemode-Lichtwellenleiter-Reflektometer (OTDR) - optische Länge des Lichtwellenleiters Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Am festen Standort (S) und außerhalb (P) Wellenlänge 1310 nm Wellenlänge 1383 nm Wellenlänge 1490 nm Wellenlänge 1550 nm Wellenlänge 1625 nm Wellenlänge 1650 nm LMEEiO/21 auf Grundlage von PN-EN 61746-1:2011","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Reflektometer (OTDR)\nSinglemode-Lichtwellenleiter-Reflektometer (OTDR)\n- optische Länge des Lichtwellenleiters","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 1310 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"波长 1383 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"波长 1490 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"波长 1550 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"波长 1625 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"波长 1650 nm","range":"up to 25 km","cmc":"0,3 m"}],"reference_zh":"LMEEiO/21 依据PN-EN 61746-1:2011","regulatory_area_zh":"光电量","search_zh":"光时域反射仪（OTDR） 单模光时域反射仪 - 光纤光学长度 校准 — 光电量 内部程序；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 在固定地点 (S) 及固定地点以外 (P) 波长 1310 nm 波长 1383 nm 波长 1490 nm 波长 1550 nm 波长 1625 nm 波长 1650 nm LMEEiO/21 依据PN-EN 61746-1:2011","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光时域反射仪（OTDR）\n单模光时域反射仪\n- 光纤光学长度","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 1310 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"vlnová délka 1383 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"vlnová délka 1490 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"vlnová délka 1550 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"vlnová délka 1625 nm","range":"up to 25 km","cmc":"0,3 m"},{"name":"vlnová délka 1650 nm","range":"up to 25 km","cmc":"0,3 m"}],"reference_cs":"LMEEiO/21 na základě PN-EN 61746-1:2011","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Optické reflektometry (OTDR) Jednovidové optické reflektometry - optická délka optického vlákna Kalibrace — Optoelektronické veličiny Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) vlnová délka 1310 nm vlnová délka 1383 nm vlnová délka 1490 nm vlnová délka 1550 nm vlnová délka 1625 nm vlnová délka 1650 nm LMEEiO/21 na základě PN-EN 61746-1:2011","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Optické reflektometry (OTDR)\nJednovidové optické reflektometry\n- optická délka optického vlákna"},{"_id":"b97fdf1aadb0efe8e73f175a","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Reflektometry światłowodowe wielomodowe\n- długość optyczna światłowodu","test_object_en":"Multimode optical time-domain reflectometers\n- optical fibre length","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 850 nm","range":"do 5 km","cmc":"1,4 m"},{"name":"długość fali 1300 nm","range":"do 5 km","cmc":"0,4 m"}],"parameters_en":[{"name":"wavelength 850 nm","range":"up to 5 km","cmc":"1,4 m"},{"name":"wavelength 1300 nm","range":"up to 5 km","cmc":"0,4 m"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 850 nm do 5 km CMC 1,4 m\ndługość fali 1300 nm do 5 km CMC 0,4 m\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21 w oparciu o PN-EN 61746-2:2011","norm_bases":["LMEEiO/21","PN-EN 61746-2:2011"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Reflektometry światłowodowe wielomodowe\n- długość optyczna światłowodu Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 850 nm do 5 km CMC 1,4 m\ndługość fali 1300 nm do 5 km CMC 0,4 m\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21 w oparciu o PN-EN 61746-2:2011 Reflektometry swiatlowodowe wielomodowe\n- dlugosc optyczna swiatlowodu Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 850 nm do 5 km CMC 1,4 m\ndlugosc fali 1300 nm do 5 km CMC 0,4 m\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21 w oparciu o PN-EN 61746-2:2011","search_en":"Multimode optical time-domain reflectometers - optical fibre length Calibration — Optoelectronic quantities Internal procedure; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure At permanent location (S) and outside of it (P) wavelength 850 nm wavelength 1300 nm LMEEiO/21 based on PN-EN 61746-2:2011","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":98,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/21 based on PN-EN 61746-2:2011","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 850 nm","range":"up to 5 km","cmc":"1,4 m"},{"name":"Wellenlänge 1300 nm","range":"up to 5 km","cmc":"0,4 m"}],"reference_de":"LMEEiO/21 auf Grundlage von PN-EN 61746-2:2011","regulatory_area_de":"Optoelektronische Größen","search_de":"Multimode-Lichtwellenleiter-Reflektometer (OTDR) - optische Länge des Lichtwellenleiters Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Am festen Standort (S) und außerhalb (P) Wellenlänge 850 nm Wellenlänge 1300 nm LMEEiO/21 auf Grundlage von PN-EN 61746-2:2011","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Multimode-Lichtwellenleiter-Reflektometer (OTDR)\n- optische Länge des Lichtwellenleiters","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 850 nm","range":"up to 5 km","cmc":"1,4 m"},{"name":"波长 1300 nm","range":"up to 5 km","cmc":"0,4 m"}],"reference_zh":"LMEEiO/21 依据PN-EN 61746-2:2011","regulatory_area_zh":"光电量","search_zh":"多模光时域反射仪 - 光纤光学长度 校准 — 光电量 内部程序；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 在固定地点 (S) 及固定地点以外 (P) 波长 850 nm 波长 1300 nm LMEEiO/21 依据PN-EN 61746-2:2011","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"多模光时域反射仪\n- 光纤光学长度","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 850 nm","range":"up to 5 km","cmc":"1,4 m"},{"name":"vlnová délka 1300 nm","range":"up to 5 km","cmc":"0,4 m"}],"reference_cs":"LMEEiO/21 na základě PN-EN 61746-2:2011","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Mnohovidové optické reflektometry - optická délka optického vlákna Kalibrace — Optoelektronické veličiny Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) vlnová délka 850 nm vlnová délka 1300 nm LMEEiO/21 na základě PN-EN 61746-2:2011","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Mnohovidové optické reflektometry\n- optická délka optického vlákna"},{"_id":"34a316d4ce0446b278030487","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Światłowodowe wzorce długości drogi optycznej\n- długość optyczna światłowodu","test_object_en":"Optical fibre path length standards\n- optical fibre length","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"","range":"0 km do 50 km","cmc":"0,15 m"}],"parameters_en":[{"name":"","range":"0 km to 50 km","cmc":"0,15 m"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\n0 km do 50 km CMC 0,15 m\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LMEEiO/47 w oparciu o PN-EN 61746-1:2011","norm_bases":["LMEEiO/47","PN-EN 61746-1:2011"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Światłowodowe wzorce długości drogi optycznej\n- długość optyczna światłowodu Wzorcowanie — Wielkości optoelektroniczne\n0 km do 50 km CMC 0,15 m\nProcedura wewnętrzna; W stałej lokalizacji (S) LMEEiO/47 w oparciu o PN-EN 61746-1:2011 Swiatlowodowe wzorce dlugosci drogi optycznej\n- dlugosc optyczna swiatlowodu Wzorcowanie — Wielkosci optoelektroniczne\n0 km do 50 km CMC 0,15 m\nProcedura wewnetrzna; W stalej lokalizacji (S) LMEEiO/47 w oparciu o PN-EN 61746-1:2011","search_en":"Optical fibre path length standards - optical fibre length Calibration — Optoelectronic quantities Internal procedure; At permanent location (S) Optoelectronic quantities Internal procedure At permanent location (S) LMEEiO/47 based on PN-EN 61746-1:2011","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":99,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/47 based on PN-EN 61746-1:2011","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"","range":"0 km to 50 km","cmc":"0,15 m"}],"reference_de":"LMEEiO/47 auf Grundlage von PN-EN 61746-1:2011","regulatory_area_de":"Optoelektronische Größen","search_de":"Lichtwellenleiter-Normale der optischen Weglänge - optische Länge des Lichtwellenleiters Kalibrierung — Optoelektronische Größen Internes Verfahren; Am festen Standort (S) Optoelektronische Größen Internes Verfahren Am festen Standort (S) LMEEiO/47 auf Grundlage von PN-EN 61746-1:2011","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Lichtwellenleiter-Normale der optischen Weglänge\n- optische Länge des Lichtwellenleiters","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"","range":"0 km to 50 km","cmc":"0,15 m"}],"reference_zh":"LMEEiO/47 依据PN-EN 61746-1:2011","regulatory_area_zh":"光电量","search_zh":"光纤光程长度标准 - 光纤光学长度 校准 — 光电量 内部程序；在固定地点 (S) 光电量 内部程序 在固定地点 (S) LMEEiO/47 依据PN-EN 61746-1:2011","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"光纤光程长度标准\n- 光纤光学长度","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"","range":"0 km to 50 km","cmc":"0,15 m"}],"reference_cs":"LMEEiO/47 na základě PN-EN 61746-1:2011","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Vláknové etalony délky optické dráhy - optická délka optického vlákna Kalibrace — Optoelektronické veličiny Vnitřní postup; Ve stálé lokalitě (S) Optoelektronické veličiny Vnitřní postup Ve stálé lokalitě (S) LMEEiO/47 na základě PN-EN 61746-1:2011","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Vláknové etalony délky optické dráhy\n- optická délka optického vlákna"},{"_id":"993af32e383580ca7b7028f2","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Tłumiki optyczne\nSprzęgacze optyczne\nPrzełączniki optyczne\nObiekty optoelektroniczne światłowodowe\n- tłumienność","test_object_en":"Optical attenuators\nOptical couplers\nOptical switches\nFibre-optic optoelectronic objects\n- attenuation","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długości fali: 850 nm; 1260 nm do 1360 nm 1480 nm do 1680 nm","range":"0 dB do 70 dB","cmc":"0,039 dB"},{"name":"długości fali: 850 nm; 1260 nm do 1360 nm 1480 nm do 1680 nm","range":"0 dB do 70 dB","cmc":"0,9 %"}],"parameters_en":[{"name":"wavelengths: 850 nm; 1260 nm to 1360 nm 1480 nm to 1680 nm","range":"0 dB to 70 dB","cmc":"0,039 dB"},{"name":"wavelengths: 850 nm; 1260 nm to 1360 nm 1480 nm to 1680 nm","range":"0 dB to 70 dB","cmc":"0,9 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługości fali: 850 nm; 1260 nm do 1360 nm 1480 nm do 1680 nm 0 dB do 70 dB CMC 0,039 dB\ndługości fali: 850 nm; 1260 nm do 1360 nm 1480 nm do 1680 nm 0 dB do 70 dB CMC 0,9 %\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/23\nw oparciu o\nPN-EN-61280-4-2:2014\nAnnex C","norm_bases":["LMEEiO/23","PN-EN-61280-4-2:2014"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Tłumiki optyczne\nSprzęgacze optyczne\nPrzełączniki optyczne\nObiekty optoelektroniczne światłowodowe\n- tłumienność Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługości fali: 850 nm; 1260 nm do 1360 nm 1480 nm do 1680 nm 0 dB do 70 dB CMC 0,039 dB\ndługości fali: 850 nm; 1260 nm do 1360 nm 1480 nm do 1680 nm 0 dB do 70 dB CMC 0,9 %\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/23\nw oparciu o\nPN-EN-61280-4-2:2014\nAnnex C Tlumiki optyczne\nSprzegacze optyczne\nPrzelaczniki optyczne\nObiekty optoelektroniczne swiatlowodowe\n- tlumiennosc Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosci fali: 850 nm; 1260 nm do 1360 nm 1480 nm do 1680 nm 0 dB do 70 dB CMC 0,039 dB\ndlugosci fali: 850 nm; 1260 nm do 1360 nm 1480 nm do 1680 nm 0 dB do 70 dB CMC 0,9 %\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/23\nw oparciu o\nPN-EN-61280-4-2:2014\nAnnex C","search_en":"Optical attenuators Optical couplers Optical switches Fibre-optic optoelectronic objects - attenuation Calibration — Optoelectronic quantities Internal procedure; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure At permanent location (S) and outside of it (P) wavelengths: 850 nm; 1260 nm to 1360 nm 1480 nm to 1680 nm wavelengths: 850 nm; 1260 nm to 1360 nm 1480 nm to 1680 nm LMEEiO/23 based on PN-EN-61280-4-2:2014 Annex C","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":100,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/23\nbased on\nPN-EN-61280-4-2:2014\nAnnex C","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlängen: 850 nm; 1260 nm bis 1360 nm 1480 nm bis 1680 nm","range":"0 dB to 70 dB","cmc":"0,039 dB"},{"name":"Wellenlängen: 850 nm; 1260 nm bis 1360 nm 1480 nm bis 1680 nm","range":"0 dB to 70 dB","cmc":"0,9 %"}],"reference_de":"LMEEiO/23\nauf Grundlage von\nPN-EN-61280-4-2:2014\nAnnex C","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Dämpfungsglieder Optische Koppler Optische Schalter Optoelektronische Lichtwellenleiterobjekte - Dämpfung Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Am festen Standort (S) und außerhalb (P) Wellenlängen: 850 nm; 1260 nm bis 1360 nm 1480 nm bis 1680 nm Wellenlängen: 850 nm; 1260 nm bis 1360 nm 1480 nm bis 1680 nm LMEEiO/23 auf Grundlage von PN-EN-61280-4-2:2014 Annex C","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Dämpfungsglieder\nOptische Koppler\nOptische Schalter\nOptoelektronische Lichtwellenleiterobjekte\n- Dämpfung","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长：850 nm; 1260 nm 至 1360 nm 1480 nm 至 1680 nm","range":"0 dB to 70 dB","cmc":"0,039 dB"},{"name":"波长：850 nm; 1260 nm 至 1360 nm 1480 nm 至 1680 nm","range":"0 dB to 70 dB","cmc":"0,9 %"}],"reference_zh":"LMEEiO/23\n依据\nPN-EN-61280-4-2:2014\nAnnex C","regulatory_area_zh":"光电量","search_zh":"光衰减器 光耦合器 光开关 光纤光电器件 - 衰减 校准 — 光电量 内部程序；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 在固定地点 (S) 及固定地点以外 (P) 波长：850 nm; 1260 nm 至 1360 nm 1480 nm 至 1680 nm 波长：850 nm; 1260 nm 至 1360 nm 1480 nm 至 1680 nm LMEEiO/23 依据 PN-EN-61280-4-2:2014 Annex C","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光衰减器\n光耦合器\n光开关\n光纤光电器件\n- 衰减","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnové délky: 850 nm; 1260 nm až 1360 nm 1480 nm až 1680 nm","range":"0 dB to 70 dB","cmc":"0,039 dB"},{"name":"vlnové délky: 850 nm; 1260 nm až 1360 nm 1480 nm až 1680 nm","range":"0 dB to 70 dB","cmc":"0,9 %"}],"reference_cs":"LMEEiO/23\nna základě\nPN-EN-61280-4-2:2014\nAnnex C","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Optické útlumové články Optické vazební členy Optické přepínače Vláknové optoelektronické objekty - útlum Kalibrace — Optoelektronické veličiny Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) vlnové délky: 850 nm; 1260 nm až 1360 nm 1480 nm až 1680 nm vlnové délky: 850 nm; 1260 nm až 1360 nm 1480 nm až 1680 nm LMEEiO/23 na základě PN-EN-61280-4-2:2014 Annex C","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Optické útlumové články\nOptické vazební členy\nOptické přepínače\nVláknové optoelektronické objekty\n- útlum"},{"_id":"c4efacfced2f2649b42314e4","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Reflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\n- tłumienność jednostkowa","test_object_en":"Optical time-domain reflectometers (OTDR)\nSingle-mode optical time-domain reflectometers\n- attenuation coefficient","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 1310 nm","range":"0,326 dB/km do 0,334 dB/km","cmc":"0,008 dB/km"},{"name":"długość fali 1550 nm","range":"0,186 dB/km do 0,194 dB/km","cmc":"0,008 dB/km"}],"parameters_en":[{"name":"wavelength 1310 nm","range":"0,326 dB/km to 0,334 dB/km","cmc":"0,008 dB/km"},{"name":"wavelength 1550 nm","range":"0,186 dB/km to 0,194 dB/km","cmc":"0,008 dB/km"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1310 nm 0,326 dB/km do 0,334 dB/km CMC 0,008 dB/km\ndługość fali 1550 nm 0,186 dB/km do 0,194 dB/km CMC 0,008 dB/km\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21","norm_bases":["LMEEiO/21"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Reflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\n- tłumienność jednostkowa Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1310 nm 0,326 dB/km do 0,334 dB/km CMC 0,008 dB/km\ndługość fali 1550 nm 0,186 dB/km do 0,194 dB/km CMC 0,008 dB/km\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21 Reflektometry optyczne (OTDR)\nReflektometry swiatlowodowe jednomodowe\n- tlumiennosc jednostkowa Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 1310 nm 0,326 dB/km do 0,334 dB/km CMC 0,008 dB/km\ndlugosc fali 1550 nm 0,186 dB/km do 0,194 dB/km CMC 0,008 dB/km\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21","search_en":"Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers - attenuation coefficient Calibration — Optoelectronic quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Direct method At permanent location (S) and outside of it (P) wavelength 1310 nm wavelength 1550 nm LMEEiO/21","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":101,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 1310 nm","range":"0,326 dB/km to 0,334 dB/km","cmc":"0,008 dB/km"},{"name":"Wellenlänge 1550 nm","range":"0,186 dB/km to 0,194 dB/km","cmc":"0,008 dB/km"}],"regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Reflektometer (OTDR) Singlemode-Lichtwellenleiter-Reflektometer (OTDR) - Dämpfungskoeffizient Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) Wellenlänge 1310 nm Wellenlänge 1550 nm LMEEiO/21","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Reflektometer (OTDR)\nSinglemode-Lichtwellenleiter-Reflektometer (OTDR)\n- Dämpfungskoeffizient","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 1310 nm","range":"0,326 dB/km to 0,334 dB/km","cmc":"0,008 dB/km"},{"name":"波长 1550 nm","range":"0,186 dB/km to 0,194 dB/km","cmc":"0,008 dB/km"}],"regulatory_area_zh":"光电量","search_zh":"光时域反射仪（OTDR） 单模光时域反射仪 - 衰减系数 校准 — 光电量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 波长 1310 nm 波长 1550 nm LMEEiO/21","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光时域反射仪（OTDR）\n单模光时域反射仪\n- 衰减系数","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 1310 nm","range":"0,326 dB/km to 0,334 dB/km","cmc":"0,008 dB/km"},{"name":"vlnová délka 1550 nm","range":"0,186 dB/km to 0,194 dB/km","cmc":"0,008 dB/km"}],"regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Optické reflektometry (OTDR) Jednovidové optické reflektometry - měrný útlum Kalibrace — Optoelektronické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) vlnová délka 1310 nm vlnová délka 1550 nm LMEEiO/21","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Optické reflektometry (OTDR)\nJednovidové optické reflektometry\n- měrný útlum"},{"_id":"98b0862cb68c26107556fec4","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Reflektometry optyczne (OTDR)\nReflektometry światłowodowe wielomodowe\n- tłumienność jednostkowa","test_object_en":"Optical time-domain reflectometers (OTDR)\nMultimode optical time-domain reflectometers\n- attenuation coefficient","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 850 nm","range":"2,566 dB/km do 2,718 dB/km","cmc":"0,053 dB/km"},{"name":"długość fali 1300 nm","range":"0,470 dB/km do 0,526 dB/km","cmc":"0,021 dB/km"}],"parameters_en":[{"name":"wavelength 850 nm","range":"2,566 dB/km to 2,718 dB/km","cmc":"0,053 dB/km"},{"name":"wavelength 1300 nm","range":"0,470 dB/km to 0,526 dB/km","cmc":"0,021 dB/km"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 850 nm 2,566 dB/km do 2,718 dB/km CMC 0,053 dB/km\ndługość fali 1300 nm 0,470 dB/km do 0,526 dB/km CMC 0,021 dB/km\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21","norm_bases":["LMEEiO/21"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Reflektometry optyczne (OTDR)\nReflektometry światłowodowe wielomodowe\n- tłumienność jednostkowa Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 850 nm 2,566 dB/km do 2,718 dB/km CMC 0,053 dB/km\ndługość fali 1300 nm 0,470 dB/km do 0,526 dB/km CMC 0,021 dB/km\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21 Reflektometry optyczne (OTDR)\nReflektometry swiatlowodowe wielomodowe\n- tlumiennosc jednostkowa Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 850 nm 2,566 dB/km do 2,718 dB/km CMC 0,053 dB/km\ndlugosc fali 1300 nm 0,470 dB/km do 0,526 dB/km CMC 0,021 dB/km\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21","search_en":"Optical time-domain reflectometers (OTDR) Multimode optical time-domain reflectometers - attenuation coefficient Calibration — Optoelectronic quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Direct method At permanent location (S) and outside of it (P) wavelength 850 nm wavelength 1300 nm LMEEiO/21","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":102,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 850 nm","range":"2,566 dB/km to 2,718 dB/km","cmc":"0,053 dB/km"},{"name":"Wellenlänge 1300 nm","range":"0,470 dB/km to 0,526 dB/km","cmc":"0,021 dB/km"}],"regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Reflektometer (OTDR) Multimode-Lichtwellenleiter-Reflektometer (OTDR) - Dämpfungskoeffizient Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) Wellenlänge 850 nm Wellenlänge 1300 nm LMEEiO/21","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Reflektometer (OTDR)\nMultimode-Lichtwellenleiter-Reflektometer (OTDR)\n- Dämpfungskoeffizient","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 850 nm","range":"2,566 dB/km to 2,718 dB/km","cmc":"0,053 dB/km"},{"name":"波长 1300 nm","range":"0,470 dB/km to 0,526 dB/km","cmc":"0,021 dB/km"}],"regulatory_area_zh":"光电量","search_zh":"光时域反射仪（OTDR） 多模光时域反射仪 - 衰减系数 校准 — 光电量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 波长 850 nm 波长 1300 nm LMEEiO/21","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光时域反射仪（OTDR）\n多模光时域反射仪\n- 衰减系数","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 850 nm","range":"2,566 dB/km to 2,718 dB/km","cmc":"0,053 dB/km"},{"name":"vlnová délka 1300 nm","range":"0,470 dB/km to 0,526 dB/km","cmc":"0,021 dB/km"}],"regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Optické reflektometry (OTDR) Mnohovidové optické reflektometry - měrný útlum Kalibrace — Optoelektronické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) vlnová délka 850 nm vlnová délka 1300 nm LMEEiO/21","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Optické reflektometry (OTDR)\nMnohovidové optické reflektometry\n- měrný útlum"},{"_id":"12ce235dc01523d7f9079148","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Reflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\n- liniowość skali tłumienności (odchylenie skali tłumienności)","test_object_en":"Optical time-domain reflectometers (OTDR)\nSingle-mode optical time-domain reflectometers\n- attenuation scale linearity (attenuation scale deviation)","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"","range":"zakres długości fali 1310 nm; zakres długości fali 1550 nm","cmc":"0,01 dB/dB"}],"parameters_en":[{"name":"","range":"wavelength range 1310 nm; wavelength range 1550 nm","cmc":"0,01 dB/dB"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nzakres długości fali 1310 nm; zakres długości fali 1550 nm CMC 0,01 dB/dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21","norm_bases":["LMEEiO/21"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Reflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\n- liniowość skali tłumienności (odchylenie skali tłumienności) Wzorcowanie — Wielkości optoelektroniczne\nzakres długości fali 1310 nm; zakres długości fali 1550 nm CMC 0,01 dB/dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21 Reflektometry optyczne (OTDR)\nReflektometry swiatlowodowe jednomodowe\n- liniowosc skali tlumiennosci (odchylenie skali tlumiennosci) Wzorcowanie — Wielkosci optoelektroniczne\nzakres dlugosci fali 1310 nm; zakres dlugosci fali 1550 nm CMC 0,01 dB/dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21","search_en":"Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers - attenuation scale linearity (attenuation scale deviation) Calibration — Optoelectronic quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/21","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":103,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"","range":"wavelength range 1310 nm; wavelength range 1550 nm","cmc":"0,01 dB/dB"}],"regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Reflektometer (OTDR) Singlemode-Lichtwellenleiter-Reflektometer (OTDR) - Linearität der Dämpfungsskala (Abweichung der Dämpfungsskala) Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/21","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Reflektometer (OTDR)\nSinglemode-Lichtwellenleiter-Reflektometer (OTDR)\n- Linearität der Dämpfungsskala (Abweichung der Dämpfungsskala)","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"","range":"wavelength range 1310 nm; wavelength range 1550 nm","cmc":"0,01 dB/dB"}],"regulatory_area_zh":"光电量","search_zh":"光时域反射仪（OTDR） 单模光时域反射仪 - 衰减标度线性度（衰减标度偏差） 校准 — 光电量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/21","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光时域反射仪（OTDR）\n单模光时域反射仪\n- 衰减标度线性度（衰减标度偏差）","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"","range":"wavelength range 1310 nm; wavelength range 1550 nm","cmc":"0,01 dB/dB"}],"regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Optické reflektometry (OTDR) Jednovidové optické reflektometry - linearita stupnice útlumu (odchylka stupnice útlumu) Kalibrace — Optoelektronické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/21","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Optické reflektometry (OTDR)\nJednovidové optické reflektometry\n- linearita stupnice útlumu (odchylka stupnice útlumu)"},{"_id":"8fa6e86ff063160581bf52cd","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Reflektometry światłowodowe wielomodowe\n- liniowość skali tłumienności (odchylenie skali tłumienności)","test_object_en":"Multimode optical time-domain reflectometers\n- attenuation scale linearity (attenuation scale deviation)","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"","range":"zakres długości fali 850 nm; zakres długości fali 1300 nm","cmc":"0,02 dB/dB"}],"parameters_en":[{"name":"","range":"wavelength range 850 nm; wavelength range 1300 nm","cmc":"0,02 dB/dB"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nzakres długości fali 850 nm; zakres długości fali 1300 nm CMC 0,02 dB/dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21","norm_bases":["LMEEiO/21"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Reflektometry światłowodowe wielomodowe\n- liniowość skali tłumienności (odchylenie skali tłumienności) Wzorcowanie — Wielkości optoelektroniczne\nzakres długości fali 850 nm; zakres długości fali 1300 nm CMC 0,02 dB/dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21 Reflektometry swiatlowodowe wielomodowe\n- liniowosc skali tlumiennosci (odchylenie skali tlumiennosci) Wzorcowanie — Wielkosci optoelektroniczne\nzakres dlugosci fali 850 nm; zakres dlugosci fali 1300 nm CMC 0,02 dB/dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21","search_en":"Multimode optical time-domain reflectometers - attenuation scale linearity (attenuation scale deviation) Calibration — Optoelectronic quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/21","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":104,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"","range":"wavelength range 850 nm; wavelength range 1300 nm","cmc":"0,02 dB/dB"}],"regulatory_area_de":"Optoelektronische Größen","search_de":"Multimode-Lichtwellenleiter-Reflektometer (OTDR) - Linearität der Dämpfungsskala (Abweichung der Dämpfungsskala) Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/21","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Multimode-Lichtwellenleiter-Reflektometer (OTDR)\n- Linearität der Dämpfungsskala (Abweichung der Dämpfungsskala)","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"","range":"wavelength range 850 nm; wavelength range 1300 nm","cmc":"0,02 dB/dB"}],"regulatory_area_zh":"光电量","search_zh":"多模光时域反射仪 - 衰减标度线性度（衰减标度偏差） 校准 — 光电量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/21","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"多模光时域反射仪\n- 衰减标度线性度（衰减标度偏差）","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"","range":"wavelength range 850 nm; wavelength range 1300 nm","cmc":"0,02 dB/dB"}],"regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Mnohovidové optické reflektometry - linearita stupnice útlumu (odchylka stupnice útlumu) Kalibrace — Optoelektronické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/21","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Mnohovidové optické reflektometry\n- linearita stupnice útlumu (odchylka stupnice útlumu)"},{"_id":"6da6ec20fe9d39782e5497bb","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki tłumienności odbicia (reflektancji)\n– tłumienność odbicia (reflektancja)","test_object_en":"Return loss (reflectance) meters\n– return loss (reflectance)","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali: 850 nm, 1300 nm, 1310 nm, 1550 nm","range":"3,5 dB do 50 dB","cmc":"0,32 dB"},{"name":"długość fali: 850 nm, 1300 nm, 1310 nm, 1550 nm","range":"50 dB do 65 dB","cmc":"0,66 dB"}],"parameters_en":[{"name":"wavelength: 850 nm, 1300 nm, 1310 nm, 1550 nm","range":"3,5 dB to 50 dB","cmc":"0,32 dB"},{"name":"wavelength: 850 nm, 1300 nm, 1310 nm, 1550 nm","range":"50 dB to 65 dB","cmc":"0,66 dB"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali: 850 nm, 1300 nm, 1310 nm, 1550 nm 3,5 dB do 50 dB CMC 0,32 dB\ndługość fali: 850 nm, 1300 nm, 1310 nm, 1550 nm 50 dB do 65 dB CMC 0,66 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/26","norm_bases":["LMEEiO/26"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki tłumienności odbicia (reflektancji)\n– tłumienność odbicia (reflektancja) Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali: 850 nm, 1300 nm, 1310 nm, 1550 nm 3,5 dB do 50 dB CMC 0,32 dB\ndługość fali: 850 nm, 1300 nm, 1310 nm, 1550 nm 50 dB do 65 dB CMC 0,66 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/26 Mierniki tlumiennosci odbicia (reflektancji)\n– tlumiennosc odbicia (reflektancja) Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali: 850 nm, 1300 nm, 1310 nm, 1550 nm 3,5 dB do 50 dB CMC 0,32 dB\ndlugosc fali: 850 nm, 1300 nm, 1310 nm, 1550 nm 50 dB do 65 dB CMC 0,66 dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/26","search_en":"Return loss (reflectance) meters – return loss (reflectance) Calibration — Optoelectronic quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Direct method At permanent location (S) and outside of it (P) wavelength: 850 nm, 1300 nm, 1310 nm, 1550 nm wavelength: 850 nm, 1300 nm, 1310 nm, 1550 nm LMEEiO/26","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":105,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge: 850 nm, 1300 nm, 1310 nm, 1550 nm","range":"3,5 dB to 50 dB","cmc":"0,32 dB"},{"name":"Wellenlänge: 850 nm, 1300 nm, 1310 nm, 1550 nm","range":"50 dB to 65 dB","cmc":"0,66 dB"}],"regulatory_area_de":"Optoelektronische Größen","search_de":"Rückflussdämpfungsmessgeräte (Reflexionsgrad) – Rückflussdämpfung (Reflexionsgrad) Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) Wellenlänge: 850 nm, 1300 nm, 1310 nm, 1550 nm Wellenlänge: 850 nm, 1300 nm, 1310 nm, 1550 nm LMEEiO/26","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Rückflussdämpfungsmessgeräte (Reflexionsgrad)\n– Rückflussdämpfung (Reflexionsgrad)","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长：850 nm, 1300 nm, 1310 nm, 1550 nm","range":"3,5 dB to 50 dB","cmc":"0,32 dB"},{"name":"波长：850 nm, 1300 nm, 1310 nm, 1550 nm","range":"50 dB to 65 dB","cmc":"0,66 dB"}],"regulatory_area_zh":"光电量","search_zh":"回波损耗（反射率）测量仪 – 回波损耗（反射率） 校准 — 光电量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 波长：850 nm, 1300 nm, 1310 nm, 1550 nm 波长：850 nm, 1300 nm, 1310 nm, 1550 nm LMEEiO/26","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"回波损耗（反射率）测量仪\n– 回波损耗（反射率）","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka: 850 nm, 1300 nm, 1310 nm, 1550 nm","range":"3,5 dB to 50 dB","cmc":"0,32 dB"},{"name":"vlnová délka: 850 nm, 1300 nm, 1310 nm, 1550 nm","range":"50 dB to 65 dB","cmc":"0,66 dB"}],"regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Měřiče útlumu odrazu (reflektance) – útlum odrazu (reflektance) Kalibrace — Optoelektronické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) vlnová délka: 850 nm, 1300 nm, 1310 nm, 1550 nm vlnová délka: 850 nm, 1300 nm, 1310 nm, 1550 nm LMEEiO/26","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče útlumu odrazu (reflektance)\n– útlum odrazu (reflektance)"},{"_id":"8e501b9cc90df64c6f5290ca","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Obiekty optoelektroniczne Światłowodowe\n- tłumienność odbicia (reflektancja)","test_object_en":"Fibre-optic optoelectronic objects\n- return loss (reflectance)","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"","range":"5 dB do 50 dB","cmc":"0,38 dB"},{"name":"","range":"50 dB do 68 dB","cmc":"0,48 dB"}],"parameters_en":[{"name":"","range":"5 dB to 50 dB","cmc":"0,38 dB"},{"name":"","range":"50 dB to 68 dB","cmc":"0,48 dB"}],"technique":"Metoda bezpośrednia. Pomiar zgodnie z metodą realizowaną przez przyrządy bazujące na technice OCWR i opisane w normie PN-EN-61280-4-2:2014-11 Annex E i Annex F; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct method. Measurement according to the method implemented by instruments based on the OCWR technique and described in PN-EN-61280-4-2:2014-11 Annex E and Annex F; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia. Pomiar zgodnie z metodą realizowaną przez przyrządy bazujące na technice OCWR i opisane w normie PN-EN-61280-4-2:2014-11 Annex E i Annex F","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct method. Measurement according to the method implemented by instruments based on the OCWR technique and described in PN-EN-61280-4-2:2014-11 Annex E and Annex F","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\n5 dB do 50 dB CMC 0,38 dB\n50 dB do 68 dB CMC 0,48 dB\nMetoda bezpośrednia. Pomiar zgodnie z metodą realizowaną przez przyrządy bazujące na technice OCWR i opisane w normie PN-EN-61280-4-2:2014-11 Annex E i Annex F; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/25","norm_bases":["LMEEiO/25"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Obiekty optoelektroniczne Światłowodowe\n- tłumienność odbicia (reflektancja) Wzorcowanie — Wielkości optoelektroniczne\nZakres:\n5 dB do 50 dB CMC 0,38 dB\n50 dB do 68 dB CMC 0,48 dB\nMetoda bezpośrednia. Pomiar zgodnie z metodą realizowaną przez przyrządy bazujące na technice OCWR i opisane w normie PN-EN-61280-4-2:2014-11 Annex E i Annex F; W stałej lokalizacji (S) i poza nią (P) LMEEiO/25 Obiekty optoelektroniczne Swiatlowodowe\n- tlumiennosc odbicia (reflektancja) Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\n5 dB do 50 dB CMC 0,38 dB\n50 dB do 68 dB CMC 0,48 dB\nMetoda bezposrednia. Pomiar zgodnie z metoda realizowana przez przyrzady bazujace na technice OCWR i opisane w normie PN-EN-61280-4-2:2014-11 Annex E i Annex F; W stalej lokalizacji (S) i poza nia (P) LMEEiO/25","search_en":"Fibre-optic optoelectronic objects - return loss (reflectance) Calibration — Optoelectronic quantities Direct method. Measurement according to the method implemented by instruments based on the OCWR technique and described in PN-EN-61280-4-2:2014-11 Annex E and Annex F; At permanent location (S) and outside of it (P) Optoelectronic quantities Direct method. Measurement according to the method implemented by instruments based on the OCWR technique and described in PN-EN-61280-4-2:2014-11 Annex E and Annex F At permanent location (S) and outside of it (P) LMEEiO/25","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":106,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"","range":"5 dB to 50 dB","cmc":"0,38 dB"},{"name":"","range":"50 dB to 68 dB","cmc":"0,48 dB"}],"regulatory_area_de":"Optoelektronische Größen","search_de":"Optoelektronische Lichtwellenleiterobjekte - Rückflussdämpfung (Reflexionsgrad) Kalibrierung — Optoelektronische Größen Direktes Verfahren. Messung nach dem Verfahren, das von Geräten auf Basis der OCWR-Technik umgesetzt wird und in der Norm PN-EN-61280-4-2:2014-11 Annex E und Annex F beschrieben ist; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Direktes Verfahren. Messung nach dem Verfahren, das von Geräten auf Basis der OCWR-Technik umgesetzt wird und in der Norm PN-EN-61280-4-2:2014-11 Annex E und Annex F beschrieben ist Am festen Standort (S) und außerhalb (P) LMEEiO/25","technique_de":"Direktes Verfahren. Messung nach dem Verfahren, das von Geräten auf Basis der OCWR-Technik umgesetzt wird und in der Norm PN-EN-61280-4-2:2014-11 Annex E und Annex F beschrieben ist; Am festen Standort (S) und außerhalb (P)","techniques_de":["Direktes Verfahren. Messung nach dem Verfahren, das von Geräten auf Basis der OCWR-Technik umgesetzt wird und in der Norm PN-EN-61280-4-2:2014-11 Annex E und Annex F beschrieben ist","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optoelektronische Lichtwellenleiterobjekte\n- Rückflussdämpfung (Reflexionsgrad)","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"","range":"5 dB to 50 dB","cmc":"0,38 dB"},{"name":"","range":"50 dB to 68 dB","cmc":"0,48 dB"}],"regulatory_area_zh":"光电量","search_zh":"光纤光电器件 - 回波损耗（反射率） 校准 — 光电量 直接法。按基于 OCWR 技术的仪器所实施、并在标准 PN-EN-61280-4-2:2014-11 附录 E 和附录 F 中描述的方法测量; 在固定地点 (S) 及固定地点以外 (P) 光电量 直接法。按基于 OCWR 技术的仪器所实施、并在标准 PN-EN-61280-4-2:2014-11 附录 E 和附录 F 中描述的方法测量 在固定地点 (S) 及固定地点以外 (P) LMEEiO/25","technique_zh":"直接法。按基于 OCWR 技术的仪器所实施、并在标准 PN-EN-61280-4-2:2014-11 附录 E 和附录 F 中描述的方法测量; 在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法。按基于 OCWR 技术的仪器所实施、并在标准 PN-EN-61280-4-2:2014-11 附录 E 和附录 F 中描述的方法测量","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光纤光电器件\n- 回波损耗（反射率）","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"","range":"5 dB to 50 dB","cmc":"0,38 dB"},{"name":"","range":"50 dB to 68 dB","cmc":"0,48 dB"}],"regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Optoelektronické objekty Vláknové - útlum odrazu (reflektance) Kalibrace — Optoelektronické veličiny Přímá metoda. Měření podle metody realizované přístroji založenými na technice OCWR a popsané v normě PN-EN-61280-4-2:2014-11 Annex E a Annex F; V trvalé lokalitě (S) i mimo ni (P) Optoelektronické veličiny Přímá metoda. Měření podle metody realizované přístroji založenými na technice OCWR a popsané v normě PN-EN-61280-4-2:2014-11 Annex E a Annex F V trvalé lokalitě (S) i mimo ni (P) LMEEiO/25","technique_cs":"Přímá metoda. Měření podle metody realizované přístroji založenými na technice OCWR a popsané v normě PN-EN-61280-4-2:2014-11 Annex E a Annex F; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá metoda. Měření podle metody realizované přístroji založenými na technice OCWR a popsané v normě PN-EN-61280-4-2:2014-11 Annex E a Annex F","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Optoelektronické objekty Vláknové\n- útlum odrazu (reflektance)"},{"_id":"062f236e6e8c64ca177d906a","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Reflektometry światłowodowe jednomodowe\n- tłumienność odbicia (reflektancja)","test_object_en":"Single-mode optical time-domain reflectometers\n- return loss (reflectance)","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"","range":"5 dB do 70 dB","cmc":"1 dB"}],"parameters_en":[{"name":"","range":"5 dB to 70 dB","cmc":"1 dB"}],"technique":"Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct method; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\n5 dB do 70 dB CMC 1 dB\nMetoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21","norm_bases":["LMEEiO/21"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Reflektometry światłowodowe jednomodowe\n- tłumienność odbicia (reflektancja) Wzorcowanie — Wielkości optoelektroniczne\n5 dB do 70 dB CMC 1 dB\nMetoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21 Reflektometry swiatlowodowe jednomodowe\n- tlumiennosc odbicia (reflektancja) Wzorcowanie — Wielkosci optoelektroniczne\n5 dB do 70 dB CMC 1 dB\nMetoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21","search_en":"Single-mode optical time-domain reflectometers - return loss (reflectance) Calibration — Optoelectronic quantities Direct method; At permanent location (S) and outside of it (P) Optoelectronic quantities Direct method At permanent location (S) and outside of it (P) LMEEiO/21","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":107,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"","range":"5 dB to 70 dB","cmc":"1 dB"}],"regulatory_area_de":"Optoelektronische Größen","search_de":"Singlemode-Lichtwellenleiter-Reflektometer (OTDR) - Rückflussdämpfung (Reflexionsgrad) Kalibrierung — Optoelektronische Größen Direktes Verfahren; Am festen Standort (S) und außerhalb davon (P) Optoelektronische Größen Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/21","technique_de":"Direktes Verfahren; Am festen Standort (S) und außerhalb davon (P)","techniques_de":["Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Singlemode-Lichtwellenleiter-Reflektometer (OTDR)\n- Rückflussdämpfung (Reflexionsgrad)","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"","range":"5 dB to 70 dB","cmc":"1 dB"}],"regulatory_area_zh":"光电量","search_zh":"单模光时域反射仪 - 回波损耗（反射率） 校准 — 光电量 直接法；在固定地点 (S) 及固定地点以外 (P) 光电量 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/21","technique_zh":"直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"单模光时域反射仪\n- 回波损耗（反射率）","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"","range":"5 dB to 70 dB","cmc":"1 dB"}],"regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Jednovidové optické reflektometry - útlum odrazu (reflektance) Kalibrace — Optoelektronické veličiny Přímá metoda; Ve stálé lokalitě (S) i mimo ni (P) Optoelektronické veličiny Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/21","technique_cs":"Přímá metoda; Ve stálé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Jednovidové optické reflektometry\n- útlum odrazu (reflektance)"},{"_id":"4466e6fff4f9ddc134b36246","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Mierniki tłumienności odbicia (reflektancji)\nAnalizatory widma promieniowania optycznego\nMierniki długości fali\nPrzełączniki optyczne\nObiekty optoelektroniczne światłowodowe\nSprzęgacze optyczne\nTłumiki optyczne\n- tłumienność zależna od polaryzacji (PDL), zależność polaryzacyjna wskazań mocy","test_object_en":"Return loss (reflectance) meters\nOptical spectrum analysers\nWavelength meters\nOptical switches\nFibre-optic optoelectronic objects\nOptical couplers\nOptical attenuators\n- polarization dependent loss (PDL), polarization dependence of power readings","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 1250 nm do 1600 nm","range":"0 dB do 62 dB","cmc":"0,23 %"},{"name":"długość fali 1250 nm do 1600 nm","range":"0 dB do 62 dB","cmc":"0,01 dB"}],"parameters_en":[{"name":"wavelength 1250 nm to 1600 nm","range":"0 dB to 62 dB","cmc":"0,23 %"},{"name":"wavelength 1250 nm to 1600 nm","range":"0 dB to 62 dB","cmc":"0,01 dB"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1250 nm do 1600 nm 0 dB do 62 dB CMC 0,23 %\ndługość fali 1250 nm do 1600 nm 0 dB do 62 dB CMC 0,01 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21, LMEEiO/26,\nLMEEiO/29, LMEEiO/36,\nw oparciu o\nPN-EN 61315:2019-10\noraz IEC 62129-1:2016","norm_bases":["LMEEiO/21","LMEEiO/26","LMEEiO/29","LMEEiO/36","PN-EN 61315:2019-10","IEC 62129-1:2016"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki tłumienności odbicia (reflektancji)\nAnalizatory widma promieniowania optycznego\nMierniki długości fali\nPrzełączniki optyczne\nObiekty optoelektroniczne światłowodowe\nSprzęgacze optyczne\nTłumiki optyczne\n- tłumienność zależna od polaryzacji (PDL), zależność polaryzacyjna wskazań mocy Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1250 nm do 1600 nm 0 dB do 62 dB CMC 0,23 %\ndługość fali 1250 nm do 1600 nm 0 dB do 62 dB CMC 0,01 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21, LMEEiO/26,\nLMEEiO/29, LMEEiO/36,\nw oparciu o\nPN-EN 61315:2019-10\noraz IEC 62129-1:2016 Mierniki tlumiennosci odbicia (reflektancji)\nAnalizatory widma promieniowania optycznego\nMierniki dlugosci fali\nPrzelaczniki optyczne\nObiekty optoelektroniczne swiatlowodowe\nSprzegacze optyczne\nTlumiki optyczne\n- tlumiennosc zalezna od polaryzacji (PDL), zaleznosc polaryzacyjna wskazan mocy Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 1250 nm do 1600 nm 0 dB do 62 dB CMC 0,23 %\ndlugosc fali 1250 nm do 1600 nm 0 dB do 62 dB CMC 0,01 dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21, LMEEiO/26,\nLMEEiO/29, LMEEiO/36,\nw oparciu o\nPN-EN 61315:2019-10\noraz IEC 62129-1:2016","search_en":"Return loss (reflectance) meters Optical spectrum analysers Wavelength meters Optical switches Fibre-optic optoelectronic objects Optical couplers Optical attenuators - polarization dependent loss (PDL), polarization dependence of power readings Calibration — Optoelectronic quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Direct method At permanent location (S) and outside of it (P) wavelength 1250 nm to 1600 nm wavelength 1250 nm to 1600 nm LMEEiO/21, LMEEiO/26, LMEEiO/29, LMEEiO/36, based on PN-EN 61315:2019-10 and IEC 62129-1:2016","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":108,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/21, LMEEiO/26,\nLMEEiO/29, LMEEiO/36,\nbased on\nPN-EN 61315:2019-10\nand IEC 62129-1:2016","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 1250 nm bis 1600 nm","range":"0 dB to 62 dB","cmc":"0,23 %"},{"name":"Wellenlänge 1250 nm bis 1600 nm","range":"0 dB to 62 dB","cmc":"0,01 dB"}],"reference_de":"LMEEiO/21, LMEEiO/26,\nLMEEiO/29, LMEEiO/36,\nauf Grundlage von\nPN-EN 61315:2019-10\nsowie IEC 62129-1:2016","regulatory_area_de":"Optoelektronische Größen","search_de":"Rückflussdämpfungsmessgeräte (Reflexionsgrad) Optische Spektrumanalysatoren Wellenlängenmessgeräte Optische Schalter Optoelektronische Lichtwellenleiterobjekte Optische Koppler Optische Dämpfungsglieder - polarisationsabhängige Dämpfung (PDL), Polarisationsabhängigkeit der Leistungsanzeige Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) Wellenlänge 1250 nm bis 1600 nm Wellenlänge 1250 nm bis 1600 nm LMEEiO/21, LMEEiO/26, LMEEiO/29, LMEEiO/36, auf Grundlage von PN-EN 61315:2019-10 sowie IEC 62129-1:2016","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Rückflussdämpfungsmessgeräte (Reflexionsgrad)\nOptische Spektrumanalysatoren\nWellenlängenmessgeräte\nOptische Schalter\nOptoelektronische Lichtwellenleiterobjekte\nOptische Koppler\nOptische Dämpfungsglieder\n- polarisationsabhängige Dämpfung (PDL), Polarisationsabhängigkeit der Leistungsanzeige","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 1250 nm 至 1600 nm","range":"0 dB to 62 dB","cmc":"0,23 %"},{"name":"波长 1250 nm 至 1600 nm","range":"0 dB to 62 dB","cmc":"0,01 dB"}],"reference_zh":"LMEEiO/21, LMEEiO/26,\nLMEEiO/29, LMEEiO/36,\n依据\nPN-EN 61315:2019-10\n以及 IEC 62129-1:2016","regulatory_area_zh":"光电量","search_zh":"回波损耗（反射率）测量仪 光谱分析仪 波长计 光开关 光纤光电器件 光耦合器 光衰减器 - 偏振相关损耗（PDL），功率示值的偏振相关性 校准 — 光电量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 波长 1250 nm 至 1600 nm 波长 1250 nm 至 1600 nm LMEEiO/21, LMEEiO/26, LMEEiO/29, LMEEiO/36, 依据 PN-EN 61315:2019-10 以及 IEC 62129-1:2016","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"回波损耗（反射率）测量仪\n光谱分析仪\n波长计\n光开关\n光纤光电器件\n光耦合器\n光衰减器\n- 偏振相关损耗（PDL），功率示值的偏振相关性","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 1250 nm až 1600 nm","range":"0 dB to 62 dB","cmc":"0,23 %"},{"name":"vlnová délka 1250 nm až 1600 nm","range":"0 dB to 62 dB","cmc":"0,01 dB"}],"reference_cs":"LMEEiO/21, LMEEiO/26,\nLMEEiO/29, LMEEiO/36,\nna základě\nPN-EN 61315:2019-10\na IEC 62129-1:2016","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Měřiče útlumu odrazu (reflektance) Analyzátory optického spektra Měřiče vlnové délky Optické přepínače Vláknové optoelektronické objekty Optické vazební členy Optické útlumové články - útlum závislý na polarizaci (PDL), polarizační závislost údajů výkonu Kalibrace — Optoelektronické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) vlnová délka 1250 nm až 1600 nm vlnová délka 1250 nm až 1600 nm LMEEiO/21, LMEEiO/26, LMEEiO/29, LMEEiO/36, na základě PN-EN 61315:2019-10 a IEC 62129-1:2016","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče útlumu odrazu (reflektance)\nAnalyzátory optického spektra\nMěřiče vlnové délky\nOptické přepínače\nVláknové optoelektronické objekty\nOptické vazební členy\nOptické útlumové články\n- útlum závislý na polarizaci (PDL), polarizační závislost údajů výkonu"},{"_id":"29568b60e60076764dd669c2","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Źródła promieniowania optycznego modulowane i niemodulowane\nReflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\nReflektometry światłowodowe wielomodowe\nMierniki tłumienności odbicia (reflektancji)\nZestawy do pomiaru tłumienności\nNadajniki optyczne zawarte w Analizatorach transmisji cyfrowej\n- długość fali promieniowania optycznego","test_object_en":"Modulated and unmodulated optical radiation sources\nOptical time-domain reflectometers (OTDR)\nSingle-mode optical time-domain reflectometers\nMultimode optical time-domain reflectometers\nReturn loss (reflectance) meters\nAttenuation measurement sets\nOptical transmitters included in digital transmission analysers\n- optical radiation wavelength","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"","range":"350 nm do 700 nm","cmc":"0,5 nm"},{"name":"","range":"700 nm do 1700 nm","cmc":"0,2 pm"},{"name":"","range":"1700 nm do 1750 nm","cmc":"0,5 nm"}],"parameters_en":[{"name":"","range":"350 nm to 700 nm","cmc":"0,5 nm"},{"name":"","range":"700 nm to 1700 nm","cmc":"0,2 pm"},{"name":"","range":"1700 nm to 1750 nm","cmc":"0,5 nm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\n350 nm do 700 nm CMC 0,5 nm\n700 nm do 1700 nm CMC 0,2 pm\n1700 nm do 1750 nm CMC 0,5 nm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\nw oparciu o\nPN-EN-61280-1-3:2022-04\nIEC-62522:2014","norm_bases":["LMEEiO/21","LMEEiO 22","LMEEiO/26","LMEEiO/27","LMEEiO/29","LMEEiO/36","PN-EN-61280-1-3:2022-04","IEC-62522:2014"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Źródła promieniowania optycznego modulowane i niemodulowane\nReflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\nReflektometry światłowodowe wielomodowe\nMierniki tłumienności odbicia (reflektancji)\nZestawy do pomiaru tłumienności\nNadajniki optyczne zawarte w Analizatorach transmisji cyfrowej\n- długość fali promieniowania optycznego Wzorcowanie — Wielkości optoelektroniczne\nZakres:\n350 nm do 700 nm CMC 0,5 nm\n700 nm do 1700 nm CMC 0,2 pm\n1700 nm do 1750 nm CMC 0,5 nm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\nw oparciu o\nPN-EN-61280-1-3:2022-04\nIEC-62522:2014 Zrodla promieniowania optycznego modulowane i niemodulowane\nReflektometry optyczne (OTDR)\nReflektometry swiatlowodowe jednomodowe\nReflektometry swiatlowodowe wielomodowe\nMierniki tlumiennosci odbicia (reflektancji)\nZestawy do pomiaru tlumiennosci\nNadajniki optyczne zawarte w Analizatorach transmisji cyfrowej\n- dlugosc fali promieniowania optycznego Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\n350 nm do 700 nm CMC 0,5 nm\n700 nm do 1700 nm CMC 0,2 pm\n1700 nm do 1750 nm CMC 0,5 nm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\nw oparciu o\nPN-EN-61280-1-3:2022-04\nIEC-62522:2014","search_en":"Modulated and unmodulated optical radiation sources Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers Multimode optical time-domain reflectometers Return loss (reflectance) meters Attenuation measurement sets Optical transmitters included in digital transmission analysers - optical radiation wavelength Calibration — Optoelectronic quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/21, LMEEiO 22, LMEEiO/26, LMEEiO/27, LMEEiO/29, LMEEiO/36 based on PN-EN-61280-1-3:2022-04 IEC-62522:2014","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":109,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\nbased on\nPN-EN-61280-1-3:2022-04\nIEC-62522:2014","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"","range":"350 nm to 700 nm","cmc":"0,5 nm"},{"name":"","range":"700 nm to 1700 nm","cmc":"0,2 pm"},{"name":"","range":"1700 nm to 1750 nm","cmc":"0,5 nm"}],"reference_de":"LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\nauf Grundlage von\nPN-EN-61280-1-3:2022-04\nIEC-62522:2014","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Strahlungsquellen, moduliert und unmoduliert Optische Reflektometer (OTDR) Singlemode-Lichtwellenleiter-Reflektometer (OTDR) Multimode-Lichtwellenleiter-Reflektometer (OTDR) Rückflussdämpfungsmessgeräte (Reflexionsgrad) Dämpfungsmesssätze Optische Sender in Analysatoren für digitale Übertragung - Wellenlänge der optischen Strahlung Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/21, LMEEiO 22, LMEEiO/26, LMEEiO/27, LMEEiO/29, LMEEiO/36 auf Grundlage von PN-EN-61280-1-3:2022-04 IEC-62522:2014","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Strahlungsquellen, moduliert und unmoduliert\nOptische Reflektometer (OTDR)\nSinglemode-Lichtwellenleiter-Reflektometer (OTDR)\nMultimode-Lichtwellenleiter-Reflektometer (OTDR)\nRückflussdämpfungsmessgeräte (Reflexionsgrad)\nDämpfungsmesssätze\nOptische Sender in Analysatoren für digitale Übertragung\n- Wellenlänge der optischen Strahlung","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"","range":"350 nm to 700 nm","cmc":"0,5 nm"},{"name":"","range":"700 nm to 1700 nm","cmc":"0,2 pm"},{"name":"","range":"1700 nm to 1750 nm","cmc":"0,5 nm"}],"reference_zh":"LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\n依据\nPN-EN-61280-1-3:2022-04\nIEC-62522:2014","regulatory_area_zh":"光电量","search_zh":"调制和未调制光辐射源 光时域反射仪（OTDR） 单模光时域反射仪 多模光时域反射仪 回波损耗（反射率）测量仪 衰减测量装置 数字传输分析仪中的光发射机 - 光辐射波长 校准 — 光电量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/21, LMEEiO 22, LMEEiO/26, LMEEiO/27, LMEEiO/29, LMEEiO/36 依据 PN-EN-61280-1-3:2022-04 IEC-62522:2014","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"调制和未调制光辐射源\n光时域反射仪（OTDR）\n单模光时域反射仪\n多模光时域反射仪\n回波损耗（反射率）测量仪\n衰减测量装置\n数字传输分析仪中的光发射机\n- 光辐射波长","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"","range":"350 nm to 700 nm","cmc":"0,5 nm"},{"name":"","range":"700 nm to 1700 nm","cmc":"0,2 pm"},{"name":"","range":"1700 nm to 1750 nm","cmc":"0,5 nm"}],"reference_cs":"LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\nna základě\nPN-EN-61280-1-3:2022-04\nIEC-62522:2014","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Zdroje optického záření modulované a nemodulované Optické reflektometry (OTDR) Jednovidové optické reflektometry Mnohovidové optické reflektometry Měřiče útlumu odrazu (reflektance) Soupravy pro měření útlumu Optické vysílače obsažené v analyzátorech digitálního přenosu - vlnová délka optického záření Kalibrace — Optoelektronické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/21, LMEEiO 22, LMEEiO/26, LMEEiO/27, LMEEiO/29, LMEEiO/36 na základě PN-EN-61280-1-3:2022-04 IEC-62522:2014","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Zdroje optického záření modulované a nemodulované\nOptické reflektometry (OTDR)\nJednovidové optické reflektometry\nMnohovidové optické reflektometry\nMěřiče útlumu odrazu (reflektance)\nSoupravy pro měření útlumu\nOptické vysílače obsažené v analyzátorech digitálního přenosu\n- vlnová délka optického záření"},{"_id":"d581bbf8e364ffff2aa3723d","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Analizatory widma promieniowania optycznego\nMierniki długości fali\n- długość fali promieniowania optycznego","test_object_en":"Optical spectrum analysers\nWavelength meters\n- optical radiation wavelength","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"","range":"1510 nm do 1540 nm","cmc":"0,3 pm"},{"name":"","range":"1255 nm do 1351 nm","cmc":"0,3 pm"},{"name":"","range":"1310 nm","cmc":"0,3 pm"},{"name":"","range":"1495 nm do 1640 nm","cmc":"0,3 pm"},{"name":"","range":"1532,8279 nm","cmc":"0,2 pm"},{"name":"","range":"1532,8329 nm","cmc":"0,2 pm"},{"name":"","range":"1532,8304 nm","cmc":"0,3 pm"}],"parameters_en":[{"name":"","range":"1510 nm to 1540 nm","cmc":"0,3 pm"},{"name":"","range":"1255 nm to 1351 nm","cmc":"0,3 pm"},{"name":"","range":"1310 nm","cmc":"0,3 pm"},{"name":"","range":"1495 nm to 1640 nm","cmc":"0,3 pm"},{"name":"","range":"1532,8279 nm","cmc":"0,2 pm"},{"name":"","range":"1532,8329 nm","cmc":"0,2 pm"},{"name":"","range":"1532,8304 nm","cmc":"0,3 pm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\n1510 nm do 1540 nm CMC 0,3 pm\n1255 nm do 1351 nm CMC 0,3 pm\n1310 nm CMC 0,3 pm\n1495 nm do 1640 nm CMC 0,3 pm\n1532,8279 nm CMC 0,2 pm\n1532,8329 nm CMC 0,2 pm\n1532,8304 nm CMC 0,3 pm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\nw oparciu o\nIEC 62129-1:2016\nPN-EN-62129-2:2012","norm_bases":["LMEEiO/21","LMEEiO 22","LMEEiO/26","LMEEiO/27","LMEEiO/29","LMEEiO/36","IEC 62129-1:2016","PN-EN-62129-2:2012"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Analizatory widma promieniowania optycznego\nMierniki długości fali\n- długość fali promieniowania optycznego Wzorcowanie — Wielkości optoelektroniczne\nZakres:\n1510 nm do 1540 nm CMC 0,3 pm\n1255 nm do 1351 nm CMC 0,3 pm\n1310 nm CMC 0,3 pm\n1495 nm do 1640 nm CMC 0,3 pm\n1532,8279 nm CMC 0,2 pm\n1532,8329 nm CMC 0,2 pm\n1532,8304 nm CMC 0,3 pm\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\nw oparciu o\nIEC 62129-1:2016\nPN-EN-62129-2:2012 Analizatory widma promieniowania optycznego\nMierniki dlugosci fali\n- dlugosc fali promieniowania optycznego Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\n1510 nm do 1540 nm CMC 0,3 pm\n1255 nm do 1351 nm CMC 0,3 pm\n1310 nm CMC 0,3 pm\n1495 nm do 1640 nm CMC 0,3 pm\n1532,8279 nm CMC 0,2 pm\n1532,8329 nm CMC 0,2 pm\n1532,8304 nm CMC 0,3 pm\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\nw oparciu o\nIEC 62129-1:2016\nPN-EN-62129-2:2012","search_en":"Optical spectrum analysers Wavelength meters - optical radiation wavelength Calibration — Optoelectronic quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Direct method At permanent location (S) and outside of it (P) LMEEiO/21, LMEEiO 22, LMEEiO/26, LMEEiO/27, LMEEiO/29, LMEEiO/36 based on IEC 62129-1:2016 PN-EN-62129-2:2012","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":110,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\nbased on\nIEC 62129-1:2016\nPN-EN-62129-2:2012","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"","range":"1510 nm to 1540 nm","cmc":"0,3 pm"},{"name":"","range":"1255 nm to 1351 nm","cmc":"0,3 pm"},{"name":"","range":"1310 nm","cmc":"0,3 pm"},{"name":"","range":"1495 nm to 1640 nm","cmc":"0,3 pm"},{"name":"","range":"1532,8279 nm","cmc":"0,2 pm"},{"name":"","range":"1532,8329 nm","cmc":"0,2 pm"},{"name":"","range":"1532,8304 nm","cmc":"0,3 pm"}],"reference_de":"LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\nauf Grundlage von\nIEC 62129-1:2016\nPN-EN-62129-2:2012","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Spektrumanalysatoren Wellenlängenmessgeräte - Wellenlänge der optischen Strahlung Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/21, LMEEiO 22, LMEEiO/26, LMEEiO/27, LMEEiO/29, LMEEiO/36 auf Grundlage von IEC 62129-1:2016 PN-EN-62129-2:2012","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Spektrumanalysatoren\nWellenlängenmessgeräte\n- Wellenlänge der optischen Strahlung","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"","range":"1510 nm to 1540 nm","cmc":"0,3 pm"},{"name":"","range":"1255 nm to 1351 nm","cmc":"0,3 pm"},{"name":"","range":"1310 nm","cmc":"0,3 pm"},{"name":"","range":"1495 nm to 1640 nm","cmc":"0,3 pm"},{"name":"","range":"1532,8279 nm","cmc":"0,2 pm"},{"name":"","range":"1532,8329 nm","cmc":"0,2 pm"},{"name":"","range":"1532,8304 nm","cmc":"0,3 pm"}],"reference_zh":"LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\n依据\nIEC 62129-1:2016\nPN-EN-62129-2:2012","regulatory_area_zh":"光电量","search_zh":"光谱分析仪 波长计 - 光辐射波长 校准 — 光电量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) LMEEiO/21, LMEEiO 22, LMEEiO/26, LMEEiO/27, LMEEiO/29, LMEEiO/36 依据 IEC 62129-1:2016 PN-EN-62129-2:2012","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光谱分析仪\n波长计\n- 光辐射波长","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"","range":"1510 nm to 1540 nm","cmc":"0,3 pm"},{"name":"","range":"1255 nm to 1351 nm","cmc":"0,3 pm"},{"name":"","range":"1310 nm","cmc":"0,3 pm"},{"name":"","range":"1495 nm to 1640 nm","cmc":"0,3 pm"},{"name":"","range":"1532,8279 nm","cmc":"0,2 pm"},{"name":"","range":"1532,8329 nm","cmc":"0,2 pm"},{"name":"","range":"1532,8304 nm","cmc":"0,3 pm"}],"reference_cs":"LMEEiO/21, LMEEiO 22,\nLMEEiO/26, LMEEiO/27,\nLMEEiO/29, LMEEiO/36\nna základě\nIEC 62129-1:2016\nPN-EN-62129-2:2012","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Analyzátory optického spektra Měřiče vlnové délky - vlnová délka optického záření Kalibrace — Optoelektronické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) LMEEiO/21, LMEEiO 22, LMEEiO/26, LMEEiO/27, LMEEiO/29, LMEEiO/36 na základě IEC 62129-1:2016 PN-EN-62129-2:2012","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analyzátory optického spektra\nMěřiče vlnové délky\n- vlnová délka optického záření"},{"_id":"7ec548aa4c5669cb6fca3032","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Źródła promieniowania optycznego modulowane i niemodulowane\nReflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\nReflektometry światłowodowe wielomodowe\nMierniki tłumienności odbicia (reflektancji)\nZestawy do pomiaru tłumienności\nNadajniki optyczne zawarte w Analizatorach /testerach PDH/SDH\n- współczynnik tłumienia prążków bocznych (SMSR)","test_object_en":"Modulated and unmodulated optical radiation sources\nOptical time-domain reflectometers (OTDR)\nSingle-mode optical time-domain reflectometers\nMultimode optical time-domain reflectometers\nReturn loss (reflectance) meters\nAttenuation measurement sets\nOptical transmitters included in PDH/SDH analysers/testers\n- side mode suppression ratio (SMSR)","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długości fali 350 nm do 1750 nm","range":"1 dB do 70 dB","cmc":"0,49 dB"}],"parameters_en":[{"name":"wavelengths 350 nm to 1750 nm","range":"1 dB to 70 dB","cmc":"0,49 dB"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\ndługości fali 350 nm do 1750 nm 1 dB do 70 dB CMC 0,49 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/21, LMEEiO/22,\nLMEEiO/26, LMEEiO/27\nw oparciu o\nPN-EN-61280-1-3:2022-04","norm_bases":["LMEEiO/21","LMEEiO/22","LMEEiO/26","LMEEiO/27","PN-EN-61280-1-3:2022-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Źródła promieniowania optycznego modulowane i niemodulowane\nReflektometry optyczne (OTDR)\nReflektometry światłowodowe jednomodowe\nReflektometry światłowodowe wielomodowe\nMierniki tłumienności odbicia (reflektancji)\nZestawy do pomiaru tłumienności\nNadajniki optyczne zawarte w Analizatorach /testerach PDH/SDH\n- współczynnik tłumienia prążków bocznych (SMSR) Wzorcowanie — Wielkości optoelektroniczne\ndługości fali 350 nm do 1750 nm 1 dB do 70 dB CMC 0,49 dB\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) LMEEiO/21, LMEEiO/22,\nLMEEiO/26, LMEEiO/27\nw oparciu o\nPN-EN-61280-1-3:2022-04 Zrodla promieniowania optycznego modulowane i niemodulowane\nReflektometry optyczne (OTDR)\nReflektometry swiatlowodowe jednomodowe\nReflektometry swiatlowodowe wielomodowe\nMierniki tlumiennosci odbicia (reflektancji)\nZestawy do pomiaru tlumiennosci\nNadajniki optyczne zawarte w Analizatorach /testerach PDH/SDH\n- wspolczynnik tlumienia prazkow bocznych (SMSR) Wzorcowanie — Wielkosci optoelektroniczne\ndlugosci fali 350 nm do 1750 nm 1 dB do 70 dB CMC 0,49 dB\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) LMEEiO/21, LMEEiO/22,\nLMEEiO/26, LMEEiO/27\nw oparciu o\nPN-EN-61280-1-3:2022-04","search_en":"Modulated and unmodulated optical radiation sources Optical time-domain reflectometers (OTDR) Single-mode optical time-domain reflectometers Multimode optical time-domain reflectometers Return loss (reflectance) meters Attenuation measurement sets Optical transmitters included in PDH/SDH analysers/testers - side mode suppression ratio (SMSR) Calibration — Optoelectronic quantities Internal procedure; Direct method; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Direct method At permanent location (S) and outside of it (P) wavelengths 350 nm to 1750 nm LMEEiO/21, LMEEiO/22, LMEEiO/26, LMEEiO/27 based on PN-EN-61280-1-3:2022-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":111,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/21, LMEEiO/22,\nLMEEiO/26, LMEEiO/27\nbased on\nPN-EN-61280-1-3:2022-04","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlängen 350 nm bis 1750 nm","range":"1 dB to 70 dB","cmc":"0,49 dB"}],"reference_de":"LMEEiO/21, LMEEiO/22,\nLMEEiO/26, LMEEiO/27\nauf Grundlage von\nPN-EN-61280-1-3:2022-04","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Strahlungsquellen, moduliert und unmoduliert Optische Reflektometer (OTDR) Singlemode-Lichtwellenleiter-Reflektometer (OTDR) Multimode-Lichtwellenleiter-Reflektometer (OTDR) Rückflussdämpfungsmessgeräte (Reflexionsgrad) Dämpfungsmesssätze Optische Sender in PDH/SDH-Analysatoren/-Testern - Seitenmodenunterdrückung (SMSR) Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) Wellenlängen 350 nm bis 1750 nm LMEEiO/21, LMEEiO/22, LMEEiO/26, LMEEiO/27 auf Grundlage von PN-EN-61280-1-3:2022-04","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Strahlungsquellen, moduliert und unmoduliert\nOptische Reflektometer (OTDR)\nSinglemode-Lichtwellenleiter-Reflektometer (OTDR)\nMultimode-Lichtwellenleiter-Reflektometer (OTDR)\nRückflussdämpfungsmessgeräte (Reflexionsgrad)\nDämpfungsmesssätze\nOptische Sender in PDH/SDH-Analysatoren/-Testern\n- Seitenmodenunterdrückung (SMSR)","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 350 nm 至 1750 nm","range":"1 dB to 70 dB","cmc":"0,49 dB"}],"reference_zh":"LMEEiO/21, LMEEiO/22,\nLMEEiO/26, LMEEiO/27\n依据\nPN-EN-61280-1-3:2022-04","regulatory_area_zh":"光电量","search_zh":"调制和未调制光辐射源 光时域反射仪（OTDR） 单模光时域反射仪 多模光时域反射仪 回波损耗（反射率）测量仪 衰减测量装置 PDH/SDH 分析仪/测试仪中的光发射机 - 边模抑制比（SMSR） 校准 — 光电量 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 波长 350 nm 至 1750 nm LMEEiO/21, LMEEiO/22, LMEEiO/26, LMEEiO/27 依据 PN-EN-61280-1-3:2022-04","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"调制和未调制光辐射源\n光时域反射仪（OTDR）\n单模光时域反射仪\n多模光时域反射仪\n回波损耗（反射率）测量仪\n衰减测量装置\nPDH/SDH 分析仪/测试仪中的光发射机\n- 边模抑制比（SMSR）","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnové délky 350 nm až 1750 nm","range":"1 dB to 70 dB","cmc":"0,49 dB"}],"reference_cs":"LMEEiO/21, LMEEiO/22,\nLMEEiO/26, LMEEiO/27\nna základě\nPN-EN-61280-1-3:2022-04","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Zdroje optického záření modulované a nemodulované Optické reflektometry (OTDR) Jednovidové optické reflektometry Mnohovidové optické reflektometry Měřiče útlumu odrazu (reflektance) Soupravy pro měření útlumu Optické vysílače obsažené v analyzátorech /testerech PDH/SDH - potlačení postranních módů (SMSR) Kalibrace — Optoelektronické veličiny Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) vlnové délky 350 nm až 1750 nm LMEEiO/21, LMEEiO/22, LMEEiO/26, LMEEiO/27 na základě PN-EN-61280-1-3:2022-04","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Zdroje optického záření modulované a nemodulované\nOptické reflektometry (OTDR)\nJednovidové optické reflektometry\nMnohovidové optické reflektometry\nMěřiče útlumu odrazu (reflektance)\nSoupravy pro měření útlumu\nOptické vysílače obsažené v analyzátorech /testerech PDH/SDH\n- potlačení postranních módů (SMSR)"},{"_id":"1f52b5677da91464b0e269aa","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"0 MPa do 0,1 MPa","cmc":"0,00009 MPa"},{"name":"","range":"0,1 MPa do 1 MPa","cmc":"0,0006 MPa"},{"name":"","range":"1 MPa do 60 MPa","cmc":"0,03 MPa"}],"parameters_en":[{"name":"","range":"0 MPa to 0,1 MPa","cmc":"0,00009 MPa"},{"name":"","range":"0,1 MPa to 1 MPa","cmc":"0,0006 MPa"},{"name":"","range":"1 MPa to 60 MPa","cmc":"0,03 MPa"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n0 MPa do 0,1 MPa CMC 0,00009 MPa\n0,1 MPa do 1 MPa CMC 0,0006 MPa\n1 MPa do 60 MPa CMC 0,03 MPa\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/56 w oparciu o EURAMET cg17v4.1","norm_bases":["LMEEiO/56","EURAMET cg17v4.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne Wzorcowanie — Ciśnienie\nZakres:\n0 MPa do 0,1 MPa CMC 0,00009 MPa\n0,1 MPa do 1 MPa CMC 0,0006 MPa\n1 MPa do 60 MPa CMC 0,03 MPa\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/56 w oparciu o EURAMET cg17v4.1 Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne Wzorcowanie — Cisnienie\nZakres:\n0 MPa do 0,1 MPa CMC 0,00009 MPa\n0,1 MPa do 1 MPa CMC 0,0006 MPa\n1 MPa do 60 MPa CMC 0,03 MPa\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/56 w oparciu o EURAMET cg17v4.1","search_en":"Bourdon tube pressure gauges Electronic pressure gauges Calibration — Pressure Internal procedure; At permanent location (S) and outside of it (P) Pressure Internal procedure At permanent location (S) and outside of it (P) LMEEiO/56 based on EURAMET cg17v4.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":112,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/56 based on EURAMET cg17v4.1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"0 MPa to 0,1 MPa","cmc":"0,00009 MPa"},{"name":"","range":"0,1 MPa to 1 MPa","cmc":"0,0006 MPa"},{"name":"","range":"1 MPa to 60 MPa","cmc":"0,03 MPa"}],"reference_de":"LMEEiO/56 auf Grundlage von EURAMET cg17v4.1","regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte Kalibrierung — Druck Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Druck Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/56 auf Grundlage von EURAMET cg17v4.1","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"0 MPa to 0,1 MPa","cmc":"0,00009 MPa"},{"name":"","range":"0,1 MPa to 1 MPa","cmc":"0,0006 MPa"},{"name":"","range":"1 MPa to 60 MPa","cmc":"0,03 MPa"}],"reference_zh":"LMEEiO/56 依据EURAMET cg17v4.1","regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 校准 — 压力 内部程序；在固定地点 (S) 及固定地点以外 (P) 压力 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/56 依据EURAMET cg17v4.1","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"弹簧管压力表\n电子压力计","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"0 MPa to 0,1 MPa","cmc":"0,00009 MPa"},{"name":"","range":"0,1 MPa to 1 MPa","cmc":"0,0006 MPa"},{"name":"","range":"1 MPa to 60 MPa","cmc":"0,03 MPa"}],"reference_cs":"LMEEiO/56 na základě EURAMET cg17v4.1","regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Tlak Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/56 na základě EURAMET cg17v4.1","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry"},{"_id":"41247f9beef07df33d6bed9f","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych","test_object_en":"Noble metal thermocouples\nBase metal thermocouples","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do 250 °C","cmc":"0,5 °C"}],"parameters_en":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,5 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 250 °C CMC 0,5 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LMEEiO/51 w oparciu o EURAMET cg-8 v. 3.1","norm_bases":["LMEEiO/51","EURAMET cg-8 v. 3.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 250 °C CMC 0,5 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) LMEEiO/51 w oparciu o EURAMET cg-8 v. 3.1 Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 250 °C CMC 0,5 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) LMEEiO/51 w oparciu o EURAMET cg-8 v. 3.1","search_en":"Noble metal thermocouples Base metal thermocouples Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) Temperature (electrical thermometry) Internal procedure At permanent location (S) LMEEiO/51 based on EURAMET cg-8 v. 3.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":113,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/51 based on EURAMET cg-8 v. 3.1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,5 °C"}],"reference_de":"LMEEiO/51 auf Grundlage von EURAMET cg-8 v. 3.1","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Edelmetall-Thermoelemente Thermoelemente aus unedlen Metallen Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) LMEEiO/51 auf Grundlage von EURAMET cg-8 v. 3.1","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Edelmetall-Thermoelemente\nThermoelemente aus unedlen Metallen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,5 °C"}],"reference_zh":"LMEEiO/51 依据EURAMET cg-8 v. 3.1","regulatory_area_zh":"温度（电测温）","search_zh":"贵金属热电偶 贱金属热电偶传感器 校准 — 温度（电测温） 内部程序；在固定地点 (S) 温度（电测温） 内部程序 在固定地点 (S) LMEEiO/51 依据EURAMET cg-8 v. 3.1","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"贵金属热电偶\n贱金属热电偶传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,5 °C"}],"reference_cs":"LMEEiO/51 na základě EURAMET cg-8 v. 3.1","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Termoelektrické snímače z drahých kovů Termoelektrické snímače z obecných kovů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) LMEEiO/51 na základě EURAMET cg-8 v. 3.1","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Termoelektrické snímače z drahých kovů\nTermoelektrické snímače z obecných kovů"},{"_id":"03033a115fa79ee53b2faf99","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Czujniki termometrów rezystancyjnych","test_object_en":"Resistance thermometer sensors","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do -50 °C","cmc":"0,09 °C"},{"name":"","range":"-50 °C do -30 °C","cmc":"0,06 °C"},{"name":"","range":"-30 °C do 50 °C","cmc":"0,02 °C"},{"name":"","range":"50 °C do 250 °C","cmc":"0,04 °C"}],"parameters_en":[{"name":"","range":"-80 °C do -50 °C","cmc":"0,09 °C"},{"name":"","range":"-50 °C do -30 °C","cmc":"0,06 °C"},{"name":"","range":"-30 °C to 50 °C","cmc":"0,02 °C"},{"name":"","range":"50 °C do 250 °C","cmc":"0,04 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -50 °C CMC 0,09 °C\n-50 °C do -30 °C CMC 0,06 °C\n-30 °C do 50 °C CMC 0,02 °C\n50 °C do 250 °C CMC 0,04 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"LMEEiO/51","norm_bases":["LMEEiO/51"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki termometrów rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -50 °C CMC 0,09 °C\n-50 °C do -30 °C CMC 0,06 °C\n-30 °C do 50 °C CMC 0,02 °C\n50 °C do 250 °C CMC 0,04 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) LMEEiO/51 Czujniki termometrow rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -50 °C CMC 0,09 °C\n-50 °C do -30 °C CMC 0,06 °C\n-30 °C do 50 °C CMC 0,02 °C\n50 °C do 250 °C CMC 0,04 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) LMEEiO/51","search_en":"Resistance thermometer sensors Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) LMEEiO/51","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":114,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C do -50 °C","cmc":"0,09 °C"},{"name":"","range":"-50 °C do -30 °C","cmc":"0,06 °C"},{"name":"","range":"-30 °C bis 50 °C","cmc":"0,02 °C"},{"name":"","range":"50 °C do 250 °C","cmc":"0,04 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Fühler von Widerstandsthermometern Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) LMEEiO/51","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Fühler von Widerstandsthermometern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C do -50 °C","cmc":"0,09 °C"},{"name":"","range":"-50 °C do -30 °C","cmc":"0,06 °C"},{"name":"","range":"-30 °C 至 50 °C","cmc":"0,02 °C"},{"name":"","range":"50 °C do 250 °C","cmc":"0,04 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电阻温度计传感器 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 温度（电测温） 内部程序 直接法 在固定地点 (S) LMEEiO/51","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"电阻温度计传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C do -50 °C","cmc":"0,09 °C"},{"name":"","range":"-50 °C do -30 °C","cmc":"0,06 °C"},{"name":"","range":"-30 °C do 50 °C","cmc":"0,02 °C"},{"name":"","range":"50 °C do 250 °C","cmc":"0,04 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Čidla odporových teploměrů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) LMEEiO/51","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Čidla odporových teploměrů"},{"_id":"0620cbfbec1f3ad3b22da6b6","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (with temperature recording)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do -50 °C","cmc":"0,15 °C"},{"name":"","range":"-50 °C do -30 °C","cmc":"0,10 °C"},{"name":"","range":"-30 °C do 140 °C","cmc":"0,10 °C"}],"parameters_en":[{"name":"","range":"-80 °C to -50 °C","cmc":"0,15 °C"},{"name":"","range":"-50 °C to -30 °C","cmc":"0,10 °C"},{"name":"","range":"-30 °C to 140 °C","cmc":"0,10 °C"}],"technique":"Procedura wewnętrzna; Realizacja w kalibratorze temperatury; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Performed in a temperature calibrator; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Realizacja w kalibratorze temperatury","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Performed in a temperature calibrator","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -50 °C CMC 0,15 °C\n-50 °C do -30 °C CMC 0,10 °C\n-30 °C do 140 °C CMC 0,10 °C\nProcedura wewnętrzna; Realizacja w kalibratorze temperatury; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/51","norm_bases":["LMEEiO/51"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -50 °C CMC 0,15 °C\n-50 °C do -30 °C CMC 0,10 °C\n-30 °C do 140 °C CMC 0,10 °C\nProcedura wewnętrzna; Realizacja w kalibratorze temperatury; W stałej lokalizacji (S) i poza nią (P) LMEEiO/51 Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -50 °C CMC 0,15 °C\n-50 °C do -30 °C CMC 0,10 °C\n-30 °C do 140 °C CMC 0,10 °C\nProcedura wewnetrzna; Realizacja w kalibratorze temperatury; W stalej lokalizacji (S) i poza nia (P) LMEEiO/51","search_en":"Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Calibration — Temperature (electrical thermometry) Internal procedure; Performed in a temperature calibrator; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure Performed in a temperature calibrator At permanent location (S) and outside of it (P) LMEEiO/51","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":115,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to -50 °C","cmc":"0,15 °C"},{"name":"","range":"-50 °C to -30 °C","cmc":"0,10 °C"},{"name":"","range":"-30 °C to 140 °C","cmc":"0,10 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Durchführung im Temperaturkalibrator; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Durchführung im Temperaturkalibrator Am festen Standort (S) und außerhalb (P) LMEEiO/51","technique_de":"Internes Verfahren; Durchführung im Temperaturkalibrator; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Durchführung im Temperaturkalibrator","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C to -50 °C","cmc":"0,15 °C"},{"name":"","range":"-50 °C to -30 °C","cmc":"0,10 °C"},{"name":"","range":"-30 °C to 140 °C","cmc":"0,10 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序; 在温度校准器中进行; 在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 在温度校准器中进行 在固定地点 (S) 及固定地点以外 (P) LMEEiO/51","technique_zh":"内部程序; 在温度校准器中进行; 在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在温度校准器中进行","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to -50 °C","cmc":"0,15 °C"},{"name":"","range":"-50 °C to -30 °C","cmc":"0,10 °C"},{"name":"","range":"-30 °C to 140 °C","cmc":"0,10 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Provedení v kalibrátoru teploty; V trvalé lokalitě (S) i mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup Provedení v kalibrátoru teploty V trvalé lokalitě (S) i mimo ni (P) LMEEiO/51","technique_cs":"Vnitřní postup; Provedení v kalibrátoru teploty; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Provedení v kalibrátoru teploty","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"},{"_id":"83541a2bcbb26e5acbd5bc23","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (with temperature recording)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-30 °C do 50 °C","cmc":"0,02 °C"},{"name":"","range":"50 °C do 250 °C","cmc":"0,04 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 50 °C","cmc":"0,02 °C"},{"name":"","range":"50 °C do 250 °C","cmc":"0,04 °C"}],"technique":"Procedura wewnętrzna; Realizacja w wannie cieczowej; W stałej lokalizacji (S)","technique_en":"Internal procedure; Performed in a liquid bath; At permanent location (S)","techniques":["Procedura wewnętrzna","Realizacja w wannie cieczowej","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Performed in a liquid bath","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 50 °C CMC 0,02 °C\n50 °C do 250 °C CMC 0,04 °C\nProcedura wewnętrzna; Realizacja w wannie cieczowej; W stałej lokalizacji (S)","reference":"LMEEiO/51","norm_bases":["LMEEiO/51"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 50 °C CMC 0,02 °C\n50 °C do 250 °C CMC 0,04 °C\nProcedura wewnętrzna; Realizacja w wannie cieczowej; W stałej lokalizacji (S) LMEEiO/51 Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 50 °C CMC 0,02 °C\n50 °C do 250 °C CMC 0,04 °C\nProcedura wewnetrzna; Realizacja w wannie cieczowej; W stalej lokalizacji (S) LMEEiO/51","search_en":"Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Calibration — Temperature (electrical thermometry) Internal procedure; Performed in a liquid bath; At permanent location (S) Temperature (electrical thermometry) Internal procedure Performed in a liquid bath At permanent location (S) LMEEiO/51","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":116,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-30 °C bis 50 °C","cmc":"0,02 °C"},{"name":"","range":"50 °C do 250 °C","cmc":"0,04 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Durchführung im Flüssigkeitsbad; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Durchführung im Flüssigkeitsbad Am festen Standort (S) LMEEiO/51","technique_de":"Internes Verfahren; Durchführung im Flüssigkeitsbad; Am festen Standort (S)","techniques_de":["Internes Verfahren","Durchführung im Flüssigkeitsbad","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-30 °C 至 50 °C","cmc":"0,02 °C"},{"name":"","range":"50 °C do 250 °C","cmc":"0,04 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序; 在液槽中进行; 在固定地点 (S) 温度（电测温） 内部程序 在液槽中进行 在固定地点 (S) LMEEiO/51","technique_zh":"内部程序; 在液槽中进行; 在固定地点 (S)","techniques_zh":["内部程序","在液槽中进行","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-30 °C do 50 °C","cmc":"0,02 °C"},{"name":"","range":"50 °C do 250 °C","cmc":"0,04 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Provedení v kapalinové lázni; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Provedení v kapalinové lázni Ve stálé lokalitě (S) LMEEiO/51","technique_cs":"Vnitřní postup; Provedení v kapalinové lázni; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Provedení v kapalinové lázni","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"},{"_id":"826a1aa1bfe6ed58c5662b5b","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Kalibratory temperatury","test_object_en":"Temperature calibrators","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do 400 °C","cmc":"0,7 °C"},{"name":"","range":"400 °C do 1084 °C","cmc":"1,0 °C"}],"parameters_en":[{"name":"","range":"-80 °C to 400 °C","cmc":"0,7 °C"},{"name":"","range":"400 °C to 1084 °C","cmc":"1,0 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do 400 °C CMC 0,7 °C\n400 °C do 1084 °C CMC 1,0 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/52 w oparciu o EURAMET cg-13 v. 4.0","norm_bases":["LMEEiO/52","EURAMET cg-13 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Kalibratory temperatury Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do 400 °C CMC 0,7 °C\n400 °C do 1084 °C CMC 1,0 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/52 w oparciu o EURAMET cg-13 v. 4.0 Kalibratory temperatury Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do 400 °C CMC 0,7 °C\n400 °C do 1084 °C CMC 1,0 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/52 w oparciu o EURAMET cg-13 v. 4.0","search_en":"Temperature calibrators Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure At permanent location (S) and outside of it (P) LMEEiO/52 based on EURAMET cg-13 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":117,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/52 based on EURAMET cg-13 v. 4.0","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to 400 °C","cmc":"0,7 °C"},{"name":"","range":"400 °C to 1084 °C","cmc":"1,0 °C"}],"reference_de":"LMEEiO/52 auf Grundlage von EURAMET cg-13 v. 4.0","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Temperaturkalibratoren Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/52 auf Grundlage von EURAMET cg-13 v. 4.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Temperaturkalibratoren","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C to 400 °C","cmc":"0,7 °C"},{"name":"","range":"400 °C to 1084 °C","cmc":"1,0 °C"}],"reference_zh":"LMEEiO/52 依据EURAMET cg-13 v. 4.0","regulatory_area_zh":"温度（电测温）","search_zh":"温度校准器 校准 — 温度（电测温） 内部程序；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/52 依据EURAMET cg-13 v. 4.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"温度校准器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to 400 °C","cmc":"0,7 °C"},{"name":"","range":"400 °C to 1084 °C","cmc":"1,0 °C"}],"reference_cs":"LMEEiO/52 na základě EURAMET cg-13 v. 4.0","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Kalibrátory teploty Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/52 na základě EURAMET cg-13 v. 4.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory teploty"},{"_id":"7ae83112a8b19ff2fdb8bef5","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Termostaty cieczowe","test_object_en":"Liquid thermostats","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-30 °C do 250 °C","cmc":"0,06 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 250 °C","cmc":"0,06 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-30 °C do 250 °C CMC 0,06 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/52","norm_bases":["LMEEiO/52"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-30 °C do 250 °C CMC 0,06 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/52 Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-30 °C do 250 °C CMC 0,06 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/52","search_en":"Liquid thermostats Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure At permanent location (S) and outside of it (P) LMEEiO/52","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":118,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-30 °C to 250 °C","cmc":"0,06 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Flüssigkeitsthermostate Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/52","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Flüssigkeitsthermostate","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-30 °C to 250 °C","cmc":"0,06 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"液体恒温槽 校准 — 温度（电测温） 内部程序；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/52","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"液体恒温槽","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-30 °C to 250 °C","cmc":"0,06 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Kapalinové termostaty Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/52","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kapalinové termostaty"},{"_id":"b288d972ca63c96417baaadf","lab_id":"6afad80b8989a133b76447c7","country":"PL","accr_number":"AP 015","accr_body":"PCA","test_object":"Komory termostatyczne\nKomory klimatyczne","test_object_en":"Thermostatic chambers\nClimatic chambers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-70 °C do -50 °C","cmc":"0,3 °C"},{"name":"","range":"-50 °C do 180 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"","range":"-70 °C to -50 °C","cmc":"0,3 °C"},{"name":"","range":"-50 °C to 180 °C","cmc":"0,2 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-70 °C do -50 °C CMC 0,3 °C\n-50 °C do 180 °C CMC 0,2 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"LMEEiO/52 w oparciu o EURAMET cg-20 v. 5.0","norm_bases":["LMEEiO/52","EURAMET cg-20 v. 5.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":"1) Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia.","note_en":"1) The CMC uncertainty value applies to a single measuring point in the space of the device.","search_text":"Komory termostatyczne\nKomory klimatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-70 °C do -50 °C CMC 0,3 °C\n-50 °C do 180 °C CMC 0,2 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) LMEEiO/52 w oparciu o EURAMET cg-20 v. 5.0 Komory termostatyczne\nKomory klimatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-70 °C do -50 °C CMC 0,3 °C\n-50 °C do 180 °C CMC 0,2 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) LMEEiO/52 w oparciu o EURAMET cg-20 v. 5.0","search_en":"Thermostatic chambers Climatic chambers Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure At permanent location (S) and outside of it (P) LMEEiO/52 based on EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":119,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"LMEEiO/52 based on EURAMET cg-20 v. 5.0","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-70 °C to -50 °C","cmc":"0,3 °C"},{"name":"","range":"-50 °C to 180 °C","cmc":"0,2 °C"}],"reference_de":"LMEEiO/52 auf Grundlage von EURAMET cg-20 v. 5.0","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Thermostatkammern Klimakammern Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) und außerhalb (P) LMEEiO/52 auf Grundlage von EURAMET cg-20 v. 5.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Thermostatkammern\nKlimakammern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-70 °C to -50 °C","cmc":"0,3 °C"},{"name":"","range":"-50 °C to 180 °C","cmc":"0,2 °C"}],"reference_zh":"LMEEiO/52 依据EURAMET cg-20 v. 5.0","regulatory_area_zh":"温度（电测温）","search_zh":"恒温箱 气候箱 校准 — 温度（电测温） 内部程序；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 在固定地点 (S) 及固定地点以外 (P) LMEEiO/52 依据EURAMET cg-20 v. 5.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"恒温箱\n气候箱","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-70 °C to -50 °C","cmc":"0,3 °C"},{"name":"","range":"-50 °C to 180 °C","cmc":"0,2 °C"}],"reference_cs":"LMEEiO/52 na základě EURAMET cg-20 v. 5.0","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Termostatické komory Klimatické komory Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) LMEEiO/52 na základě EURAMET cg-20 v. 5.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Termostatické komory\nKlimatické komory"}],"has_pdf":true}