🇵🇱 Instytut Energetyki - Państwowy Instytut Badawczy PL
Metrology & calibration
Instytut Energetyki - Państwowy Instytut Badawczy is a calibration laboratory accredited by PCA under number AP 013 (Warszawa, Poland). Its accreditation scope covers 55 calibration items in the following areas: Metrology & calibration. Calibrated items include: Calibrators, Multimeters, Bourdon tube pressure gauges, Electronic pressure gauges. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S), Internal procedure; Direct method; Outside of permanent location (P), Direct and indirect method; At permanent location (S).
At a glance
- Accreditation number: PCA AP 013
- Calibration items in scope: 55
- Types of calibrated items: 50
- Calibration principles used: 12
- City: Warszawa, Poland
- Valid until: 02-09-2027
- Accreditation number
- AP 013
- Accreditation body
- PCA
- Address
- ul. Augustówka 36, 02-981 Warszawa
- City
- Warszawa, Poland
- Division
- Measuring Equipment Laboratory
- Valid until
- 02-09-2027
What this laboratory calibrates (50)
- Calibrators — 10 calibration items
- Multimeters — 8 calibration items
- Bourdon tube pressure gauges — 6 calibration items
- Electronic pressure gauges — 6 calibration items
- Pressure transmitters — 6 calibration items
- Power supplies — 4 calibration items
- Temperature transmitters — 4 calibration items
- Analogue ammeters — 3 calibration items
- Analogue voltmeters — 3 calibration items
- Digital ammeters — 3 calibration items
- Digital voltmeters — 3 calibration items
- Hygrometers — 3 calibration items
- - absolute pressure (gas medium) — 2 calibration items
- - gauge pressure: negative and positive pressure (gas medium) — 2 calibration items
- - gauge pressure: positive pressure (oil) — 2 calibration items
- and 35 more
Calibration principles (12)
- Internal procedure; Direct method; At permanent location (S) — 15 calibration items
- Internal procedure; Direct method; Outside of permanent location (P) — 10 calibration items
- Direct and indirect method; At permanent location (S) — 7 calibration items
- Internal procedure; At permanent location (S) — 6 calibration items
- Direct method; Outside of permanent location (P) — 5 calibration items
- Internal procedure; Outside of permanent location (P) — 4 calibration items
- Internal procedure; Direct method; At permanent location (S) and outside of it (P) — 3 calibration items
- Indirect electrical method; At permanent location (S) — 1 calibration item
- Indirect electrical method; Outside of permanent location (P) — 1 calibration item
- Internal procedure; At permanent location (S) and outside of it (P) — 1 calibration item
- Internal procedure; Direct and indirect method; At permanent location (S) — 1 calibration item
- Internal procedure; PF = 1; At permanent location (S) — 1 calibration item
Certificate information
- Issue date
- 17.07.2026
- Issue no.
- 23
- Certificate date
- 09.01.2024
- Accreditation cycle
- 03.08.2023 — 02.09.2027
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (55)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Analogue voltmeters | Calibration — DC voltage 0 µV to 100 mV · CMC 5 · 10⁻⁶ · U + 0,5 µV 100 mV to 1 V · CMC 4 · 10⁻⁶ · U + 0,5 µV 1 V to 10 V · CMC 4 · 10⁻⁶ · U + 5 µV 10 V to 100 V · CMC 7 · 10⁻⁶ · U + 30 µV 100 V to 1000 V · CMC 8 · 10⁻⁶ · U + 0,1 mV DC voltage |
Internal procedure; Direct method; At permanent location (S) | E /I 1/ MAP | |
| 2 | Digital voltmeters Multimeters Calibrators Power supplies |
Calibration — DC voltage 0 µV to 100 mV · CMC 5 · 10⁻⁶ · U + 0,5 µV 100 mV to 1 V · CMC 4 · 10⁻⁶ · U + 0,5 µV 1 V to 10 V · CMC 4 · 10⁻⁶ · U + 5 µV 10 V to 100 V · CMC 7 · 10⁻⁶ · U + 30 µV 100 V to 1000 V · CMC 8 · 10⁻⁶ · U + 0,1 mV DC voltage |
Direct and indirect method; At permanent location (S) | EURAMET cg-15 v.3.0 | |
| 3 | Analogue voltmeters | Calibration — DC voltage 0 µV to 100 mV · CMC 42 · 10⁻⁶ · U + 1,1 µV 100 mV to 1 V · CMC 29 · 10⁻⁶ · U + 2 µV 1 V to 10 V · CMC 28 · 10⁻⁶ · U + 40 µV 10 V to 100 V · CMC 40 · 10⁻⁶ · U + 0,6 mV 100 V to 1000 V · CMC 47 · 10⁻⁶ · U + 7 mV DC voltage |
Internal procedure; Direct method; Outside of permanent location (P) | E /I 1/ MAP P4 / MAP | |
| 4 | Digital voltmeters Multimeters Calibrators Power supplies |
Calibration — DC voltage 0 µV to 100 mV · CMC 42 · 10⁻⁶ · U + 1,1 µV 100 mV to 1 V · CMC 29 · 10⁻⁶ · U + 2 µV 1 V to 10 V · CMC 28 · 10⁻⁶ · U + 40 µV 10 V to 100 V · CMC 40 · 10⁻⁶ · U + 0,6 mV 100 V to 1000 V · CMC 47 · 10⁻⁶ · U + 7 mV DC voltage |
Direct method; Outside of permanent location (P) | EURAMET cg-15 v.3.0 | |
| 5 | Analogue ammeters | Calibration — DC current 0 µA to 100 µA · CMC 13 · 10⁻⁶ · I + 40 pA 100 µA to 1 mA · CMC 13 · 10⁻⁶ · I + 0,2 nA 1 mA to 10 mA · CMC 12 · 10⁻⁶ · I + 30 nA 10 mA to 100 mA · CMC 13 · 10⁻⁶ · I + 0,01 µA 0,1 A to 1 A · CMC 13 · 10⁻⁶ · I + 0,1 µA 1 A to 3 A · CMC 11 · 10⁻⁶ · I + 32 µA 3 A to 11 A · CMC 7 · 10⁻⁶ · I + 0,35 mA DC current |
Internal procedure; Direct method; At permanent location (S) | E /I 1/ MAP | |
| 6 | Digital ammeters Multimeters |
Calibration — DC current 0 µA to 100 µA · CMC 13 · 10⁻⁶ · I + 40 pA 100 µA to 1 mA · CMC 13 · 10⁻⁶ · I + 0,2 nA 1 mA to 10 mA · CMC 12 · 10⁻⁶ · I + 30 nA 10 mA to 100 mA · CMC 13 · 10⁻⁶ · I + 0,01 µA 0,1 A to 1 A · CMC 13 · 10⁻⁶ · I + 0,1 µA 1 A to 3 A · CMC 11 · 10⁻⁶ · I + 32 µA 3 A to 11 A · CMC 7 · 10⁻⁶ · I + 0,35 mA DC current |
Direct and indirect method; At permanent location (S) | EURAMET cg-15 v.3.0 | |
| 7 | Clamp meters | Calibration — DC current 10 A to 16,5 A · CMC 2 · 10⁻³ · I + 2 mA 16,5 A to 149,999 A · CMC 2 · 10⁻³ · I + 12 mA 150 A to 550 A · CMC 2 · 10⁻³ · I + 40 mA DC current |
Internal procedure; Direct method; At permanent location (S) | E /I 2/ MAP | |
| 8 | Calibrators Power supplies |
Calibration — DC current 0 µA to 100 µA · CMC 13 · 10⁻⁶ · I + 40 pA 100 µA to 1 mA · CMC 13 · 10⁻⁶ · I + 0,2 nA 1 mA to 10 mA · CMC 12 · 10⁻⁶ · I + 30 nA 10 mA to 100 mA · CMC 13 · 10⁻⁶ · I + 0,01 µA 0,1 A to 1 A · CMC 13 · 10⁻⁶ · I + 0,1 µA 1 A to 3 A · CMC 11 · 10⁻⁶ · I + 32 µA 3 A to 10 A · CMC 7 · 10⁻⁶ · I + 0,35 mA 10 A to 30 A · CMC 10 · 10⁻⁶ · I + 3,4 mA 30 A to 100 A · CMC 120 · 10⁻⁶ · I + 0,1 mA DC current |
Direct and indirect method; At permanent location (S) | EURAMET cg-15 v.3.0 | |
| 9 | Analogue ammeters | Calibration — DC current 0,1 mA to 1 mA · CMC 31 · 10⁻⁶ · I + 2,3 nA 1 mA to 10 mA · CMC 43 · 10⁻⁶ · I + 0,11 µA 10 mA to 100 mA · CMC 31 · 10⁻⁶ · I + 0,22 µA 0,1 A to 1 A · CMC 31 · 10⁻⁶ · I + 2,2 µA 1 A to 3 A · CMC 40 · 10⁻⁶ · I + 0,11 mA 3 A to 10 A · CMC 43 · 10⁻⁶ · I + 1,1 mA 10 A to 30 A · CMC 50 · 10⁻⁶ · I + 11 mA 30 A to 100 A · CMC 100 · 10⁻⁶ · I + 9 mA DC current |
Internal procedure; Direct method; Outside of permanent location (P) | E /I 1/ MAP P4 / MAP | |
| 10 | Digital ammeters Multimeters Calibrators Power supplies |
Calibration — DC current 0,1 mA to 1 mA · CMC 31 · 10⁻⁶ · I + 2,3 nA 1 mA to 10 mA · CMC 43 · 10⁻⁶ · I + 0,11 µA 10 mA to 100 mA · CMC 31 · 10⁻⁶ · I + 0,22 µA 0,1 A to 1 A · CMC 31 · 10⁻⁶ · I + 2,2 µA 1 A to 3 A · CMC 40 · 10⁻⁶ · I + 0,11 mA 3 A to 10 A · CMC 43 · 10⁻⁶ · I + 1,1 mA 10 A to 30 A · CMC 50 · 10⁻⁶ · I + 11 mA 30 A to 100 A · CMC 100 · 10⁻⁶ · I + 9 mA DC current |
Direct method; Outside of permanent location (P) | EURAMET cg-15 v.3.0 | |
| 11 | Analogue voltmeters | Calibration — AC voltage f = 10 Hz to 40 Hz — 0,2 mV to 10 mV · CMC 34 · 10⁻⁵ · U + 3,5 µV f = 10 Hz to 40 Hz — 0,01 V to 0,1 V · CMC 8 · 10⁻⁵ · U + 4,5 µV f = 10 Hz to 40 Hz — 0,1 V to 1 V · CMC 8 · 10⁻⁵ · U + 45 µV f = 10 Hz to 40 Hz — 1 V to 10 V · CMC 8 · 10⁻⁵ · U + 0,4 mV f = 10 Hz to 40 Hz — 10 V to 100 V · CMC 23 · 10⁻⁵ · U + 4,7 mV f = 10 Hz to 40 Hz — 100 V to 1000 V · CMC 46 · 10⁻⁵ · U + 46 mV f = 40 Hz to 1 kHz — 0,2 mV to 10 mV · CMC 23 · 10⁻⁵ · U + 1,3 µV f = 40 Hz to 1 kHz — 0,01 V to 0,1 V · CMC 8 · 10⁻⁵ · U + 2,3 µV f = 40 Hz to 1 kHz — 0,1 V to 1 V · CMC 8 · 10⁻⁵ · U + 23 µV f = 40 Hz to 1 kHz — 1 V to 10 V · CMC 8 · 10⁻⁵ · U + 0,2 mV f = 40 Hz to 1 kHz — 10 V to 100 V · CMC 23 · 10⁻⁵ · U + 2,3 mV f = 40 Hz to 1 kHz — 100 V to 1000 V · CMC 46 · 10⁻⁵ · U + 23 mV f = 1 kHz to 20 kHz — 0,2 mV to 10 mV · CMC 34 · 10⁻⁵ · U + 1,3 µV f = 1 kHz to 20 kHz — 0,01 V to 0,1 V · CMC 16 · 10⁻⁵ · U + 2,3 µV f = 1 kHz to 20 kHz — 0,1 V to 1 V · CMC 16 · 10⁻⁵ · U + 23 µV f = 1 kHz to 20 kHz — 1 V to 10 V · CMC 16 · 10⁻⁵ · U + 0,4 mV f = 1 kHz to 20 kHz — 10 V to 100 V · CMC 23 · 10⁻⁵ · U + 2,3 mV f = 1 kHz to 20 kHz — 100 V to 1000 V · CMC 69 · 10⁻⁵ · U + 23 mV f = 50 kHz to 100 kHz — 0,2 mV to 10 mV · CMC 58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV f = 50 kHz to 100 kHz — 0,01 V to 0,1 V · CMC 9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV f = 50 kHz to 100 kHz — 0,1 V to 1 V · CMC 9 · 10⁻⁴ 10⁻⁵ · U + 28 µV f = 50 kHz to 100 kHz — 1 V to 10 V · CMC 9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV f = 50 kHz to 100 kHz — 10 V to 33 V · CMC 15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV f = 100 kHz to 300 kHz — 0,2 mV to 10 mV · CMC 460 · 10⁻⁴ · U + 2,2 µV f = 100 kHz to 300 kHz — 0,01 V to 0,1 V · CMC 35 · 10⁻⁴ · U + 15 µV f = 100 kHz to 300 kHz — 0,1 V to 1 V · CMC 35 · 10⁻⁴ · U + 0,1 mV f = 100 kHz to 300 kHz — 1 V to 10 V · CMC 35 · 10⁻⁴ · U + 1,1 mV f = 100 kHz to 300 kHz — 10 V to 33 V · CMC 44 · 10⁻⁴ · U + 14 mV AC voltage |
Internal procedure; Direct method; At permanent location (S) | E /I 1/ MAP | |
| 12 | Digital voltmeters Multimeters Calibrators |
Calibration — AC voltage f = 10 Hz to 40 Hz — 0,2 mV to 10 mV · CMC 34 · 10⁻⁵ · U + 3,5 µV f = 10 Hz to 40 Hz — 0,01 V to 0,1 V · CMC 8 · 10⁻⁵ · U + 4,5 µV f = 10 Hz to 40 Hz — 0,1 V to 1 V · CMC 8 · 10⁻⁵ · U + 45 µV f = 10 Hz to 40 Hz — 1 V to 10 V · CMC 8 · 10⁻⁵ · U + 0,4 mV f = 10 Hz to 40 Hz — 10 V to 100 V · CMC 23 · 10⁻⁵ · U + 4,7 mV f = 10 Hz to 40 Hz — 100 V to 1000 V · CMC 46 · 10⁻⁵ · U + 46 mV f = 40 Hz to 1 kHz — 0,2 mV to 10 mV · CMC 23 · 10⁻⁵ · U + 1,3 µV f = 40 Hz to 1 kHz — 0,01 V to 0,1 V · CMC 8 · 10⁻⁵ · U + 2,3 µV f = 40 Hz to 1 kHz — 0,1 V to 1 V · CMC 8 · 10⁻⁵ · U + 23 µV f = 40 Hz to 1 kHz — 1 V to 10 V · CMC 8 · 10⁻⁵ · U + 0,2 mV f = 40 Hz to 1 kHz — 10 V to 100 V · CMC 23 · 10⁻⁵ · U + 2,3 mV f = 40 Hz to 1 kHz — 100 V to 1000 V · CMC 46 · 10⁻⁵ · U + 23 mV f = 1 kHz to 20 kHz — 0,2 mV to 10 mV · CMC 34 · 10⁻⁵ · U + 1,3 µV f = 1 kHz to 20 kHz — 0,01 V to 0,1 V · CMC 16 · 10⁻⁵ · U + 2,3 µV f = 1 kHz to 20 kHz — 0,1 V to 1 V · CMC 16 · 10⁻⁵ · U + 23 µV f = 1 kHz to 20 kHz — 1 V to 10 V · CMC 16 · 10⁻⁵ · U + 0,4 mV f = 1 kHz to 20 kHz — 10 V to 100 V · CMC 23 · 10⁻⁵ · U + 2,3 mV f = 1 kHz to 20 kHz — 100 V to 1000 V · CMC 69 · 10⁻⁵ · U + 23 mV f = 50 kHz to 100 kHz — 0,2 mV to 10 mV · CMC 58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV f = 50 kHz to 100 kHz — 0,01 V to 0,1 V · CMC 9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV f = 50 kHz to 100 kHz — 0,1 V to 1 V · CMC 9 · 10⁻⁴ 10⁻⁵ · U + 28 µV f = 50 kHz to 100 kHz — 1 V to 10 V · CMC 9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV f = 50 kHz to 100 kHz — 10 V to 33 V · CMC 15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV f = 100 kHz to 300 kHz — 0,2 mV to 10 mV · CMC 460 · 10⁻⁴ · U + 2,2 µV f = 100 kHz to 300 kHz — 0,01 V to 0,1 V · CMC 35 · 10⁻⁴ · U + 15 µV f = 100 kHz to 300 kHz — 0,1 V to 1 V · CMC 35 · 10⁻⁴ · U + 0,1 mV f = 100 kHz to 300 kHz — 1 V to 10 V · CMC 35 · 10⁻⁴ · U + 1,1 mV f = 100 kHz to 300 kHz — 10 V to 33 V · CMC 44 · 10⁻⁴ · U + 14 mV AC voltage |
Direct and indirect method; At permanent location (S) | EURAMET cg-15 v.3.0 | |
| 13 | Calibrators | Calibration — AC voltage f = 10 Hz to 20 kHz — 0,2 mV to 100 mV · CMC 69 · 10⁻⁵ · U + 35 µV f = 10 Hz to 20 kHz — 0,1 V to 1 V · CMC 69 · 10⁻⁵ · U + 0,35 mV f = 10 Hz to 20 kHz — 1 V to 10 V · CMC 69 · 10⁻⁵ · U + 3,5 mV f = 10 Hz to 20 kHz — 10 V to 100 V · CMC 69 · 10⁻⁵ · U + 35 mV f = 10 Hz to 20 kHz — 100 V to 750 V · CMC 69 · 10⁻⁵ · U + 0,26 V f = 20 kHz to 50 kHz — 0,2 mV to 100 mV · CMC 14 · 10⁻⁴ · U + 58 µV f = 20 kHz to 50 kHz — 0,1 V to 1 V · CMC 14 · 10⁻⁴ · U + 0,58 mV f = 20 kHz to 50 kHz — 1 V to 10 V · CMC 14 · 10⁻⁴ · U + 5,8 mV f = 20 kHz to 50 kHz — 10 V to 100 V · CMC 14 · 10⁻⁴ · U + 58 mV f = 20 kHz to 50 kHz — 100 V to 750 V · CMC 14 · 10⁻⁴ · U + 0,43 V f = 50 kHz to 100 kHz — 0,2 mV to 100 mV · CMC 69· 10⁻⁴ · U + 93 µV f = 50 kHz to 100 kHz — 0,1 V to 1 V · CMC 69 · 10⁻⁴ · U + 0,93 mV f = 50 kHz to 100 kHz — 1 V to 10 V · CMC 69 · 10⁻⁴ · U + 9,3 mV f = 50 kHz to 100 kHz — 10 V to 33 V · CMC 69 · 10⁻⁴ · U + 93 mV f = 100 kHz to 300 kHz — 0,2 mV to 100 mV · CMC 46 · 10⁻³ · U + 0,58 mV f = 100 kHz to 300 kHz — 0,1 V to 1 V · CMC 46 · 10⁻³ · U + 5,8 mV f = 100 kHz to 300 kHz — 1 V to 10 V · CMC 46 · 10⁻³ · U + 58 mV f = 100 kHz to 300 kHz — 10 V to 33 V · CMC 46 · 10⁻³ · U + 0,58 V AC voltage |
Direct method; Outside of permanent location (P) | EURAMET cg-15 v.3.0 | |
| 14 | Analogue ammeters | Calibration — AC current f = 20 Hz to 45 Hz — 0,029 mA to 0,33 mA · CMC 97 · 10⁻⁵ · I + 0,12 µA f = 20 Hz to 45 Hz — 0,33 mA to 3,3 mA · CMC 78 · 10⁻⁵ · I + 0,23 µA f = 20 Hz to 45 Hz — 3,3 mA to 33 mA · CMC 78 · 10⁻⁵ · I + 2,3 µA f = 20 Hz to 45 Hz — 33 mA to 330 mA · CMC 78 · 10⁻⁵ · I + 23 µA f = 20 Hz to 45 Hz — 0,33 A to 2,2 A · CMC 15 · 10⁻⁴ · I + 0,24 mA f = 45 Hz to 65 Hz — 0,029 mA to 0,33 mA · CMC 97 · 10⁻⁵ · I + 0,19 µA f = 45 Hz to 65 Hz — 0,33 mA to 3,3 mA · CMC 78 · 10⁻⁵ · I + 0,23 µA f = 45 Hz to 65 Hz — 3,3 mA to 33 mA · CMC 69 · 10⁻⁵ · I + 2,3 µA f = 45 Hz to 65 Hz — 33 mA to 330 mA · CMC 69 · 10⁻⁵ · I + 23 µA f = 45 Hz to 65 Hz — 0,33 A to 2,2 A · CMC 75 · 10⁻⁵ · I + 0,24 mA f = 45 Hz to 65 Hz — 2,2 A to 11 A · CMC 47 · 10⁻⁵ · I + 1,6 mA f = 65 Hz to 500 Hz — 0,029 mA to 0,33 mA · CMC 97 · 10⁻⁵ · I + 0,19 µA f = 65 Hz to 500 Hz — 0,33 mA to 3,3 mA · CMC 78 · 10⁻⁵ · I + 0,23 µA f = 65 Hz to 500 Hz — 3,3 mA to 33 mA · CMC 69 · 10⁻⁵ · I + 2,3 µA f = 65 Hz to 500 Hz — 33 mA to 330 mA · CMC 69 · 10⁻⁵ · I + 23 µA f = 65 Hz to 500 Hz — 0,33 A to 2,2 A · CMC 75 · 10⁻⁵ · I + 0,24 mA f = 65 Hz to 500 Hz — 2,2 A to 11 A · CMC 76 · 10⁻⁵ · I + 1,6 mA f = 500 Hz to 1 kHz — 0,029 mA to 0,33 mA · CMC 97 · 10⁻⁵ · I + 0,19 µA f = 500 Hz to 1 kHz — 0,33 mA to 3,3 mA · CMC 78 · 10⁻⁵ · I + 0,23 µA f = 500 Hz to 1 kHz — 3,3 mA to 33 mA · CMC 69 · 10⁻⁵ · I + 2,3 µA f = 500 Hz to 1 kHz — 33 mA to 330 mA · CMC 69 · 10⁻⁵ · I + 23 µA f = 500 Hz to 1 kHz — 0,33 A to 2,2 A · CMC 75 · 10⁻⁵ · I + 0,24 mA f = 500 Hz to 1 kHz — 2,2 A to 11 A · CMC 26 · 10⁻⁴ · I + 1,5 mA f = 1 kHz to 5 kHz — 0,029 mA to 0,33 mA · CMC 30 · 10⁻⁴ · I + 0,12 µA f = 1 kHz to 5 kHz — 0,33 mA to 3,3 mA · CMC 15 · 10⁻⁴ · I + 0,23 µA f = 1 kHz to 5 kHz — 3,3 mA to 33 mA · CMC 15 · 10⁻⁴ · I + 2,3 µA f = 1 kHz to 5 kHz — 33 mA to 330 mA · CMC 15 · 10⁻⁴ · I + 23 µA f = 1 kHz to 5 kHz — 0,33 A to 2,2 A · CMC 58 · 10⁻⁴ · I + 0,29 mA f = 5 kHz to 10 kHz — 0,029 mA to 0,33 mA · CMC 96 · 10⁻⁴ · I + 0,12 µA f = 5 kHz to 10 kHz — 0,33 mA to 3,3 mA · CMC 47 · 10⁻⁴ · I + 0,44 µA f = 5 kHz to 10 kHz — 3,3 mA to 33 mA · CMC 48 · 10⁻⁴ · I + 2,2 µA f = 5 kHz to 10 kHz — 33 mA to 330 mA · CMC 48 · 10⁻⁴ · I + 22 µA AC current |
Internal procedure; Direct method; At permanent location (S) | E /I 1/ MAP | |
| 15 | Digital ammeters Multimeters |
Calibration — AC current f = 20 Hz to 45 Hz — 0,029 mA to 0,33 mA · CMC 97 · 10⁻⁵ · I + 0,12 µA f = 20 Hz to 45 Hz — 0,33 mA to 3,3 mA · CMC 78 · 10⁻⁵ · I + 0,23 µA f = 20 Hz to 45 Hz — 3,3 mA to 33 mA · CMC 78 · 10⁻⁵ · I + 2,3 µA f = 20 Hz to 45 Hz — 33 mA to 330 mA · CMC 78 · 10⁻⁵ · I + 23 µA f = 20 Hz to 45 Hz — 0,33 A to 2,2 A · CMC 15 · 10⁻⁴ · I + 0,24 mA f = 45 Hz to 65 Hz — 0,029 mA to 0,33 mA · CMC 97 · 10⁻⁵ · I + 0,19 µA f = 45 Hz to 65 Hz — 0,33 mA to 3,3 mA · CMC 78 · 10⁻⁵ · I + 0,23 µA f = 45 Hz to 65 Hz — 3,3 mA to 33 mA · CMC 69 · 10⁻⁵ · I + 2,3 µA f = 45 Hz to 65 Hz — 33 mA to 330 mA · CMC 69 · 10⁻⁵ · I + 23 µA f = 45 Hz to 65 Hz — 0,33 A to 2,2 A · CMC 75 · 10⁻⁵ · I + 0,24 mA f = 45 Hz to 65 Hz — 2,2 A to 11 A · CMC 47 · 10⁻⁵ · I + 1,6 mA f = 65 Hz to 500 Hz — 0,029 mA to 0,33 mA · CMC 97 · 10⁻⁵ · I + 0,19 µA f = 65 Hz to 500 Hz — 0,33 mA to 3,3 mA · CMC 78 · 10⁻⁵ · I + 0,23 µA f = 65 Hz to 500 Hz — 3,3 mA to 33 mA · CMC 69 · 10⁻⁵ · I + 2,3 µA f = 65 Hz to 500 Hz — 33 mA to 330 mA · CMC 69 · 10⁻⁵ · I + 23 µA f = 65 Hz to 500 Hz — 0,33 A to 2,2 A · CMC 75 · 10⁻⁵ · I + 0,24 mA f = 65 Hz to 500 Hz — 2,2 A to 11 A · CMC 76 · 10⁻⁵ · I + 1,6 mA f = 500 Hz to 1 kHz — 0,029 mA to 0,33 mA · CMC 97 · 10⁻⁵ · I + 0,19 µA f = 500 Hz to 1 kHz — 0,33 mA to 3,3 mA · CMC 78 · 10⁻⁵ · I + 0,23 µA f = 500 Hz to 1 kHz — 3,3 mA to 33 mA · CMC 69 · 10⁻⁵ · I + 2,3 µA f = 500 Hz to 1 kHz — 33 mA to 330 mA · CMC 69 · 10⁻⁵ · I + 23 µA f = 500 Hz to 1 kHz — 0,33 A to 2,2 A · CMC 75 · 10⁻⁵ · I + 0,24 mA f = 500 Hz to 1 kHz — 2,2 A to 11 A · CMC 26 · 10⁻⁴ · I + 1,5 mA f = 1 kHz to 5 kHz — 0,029 mA to 0,33 mA · CMC 30 · 10⁻⁴ · I + 0,12 µA f = 1 kHz to 5 kHz — 0,33 mA to 3,3 mA · CMC 15 · 10⁻⁴ · I + 0,23 µA f = 1 kHz to 5 kHz — 3,3 mA to 33 mA · CMC 15 · 10⁻⁴ · I + 2,3 µA f = 1 kHz to 5 kHz — 33 mA to 330 mA · CMC 15 · 10⁻⁴ · I + 23 µA f = 1 kHz to 5 kHz — 0,33 A to 2,2 A · CMC 58 · 10⁻⁴ · I + 0,29 mA f = 5 kHz to 10 kHz — 0,029 mA to 0,33 mA · CMC 96 · 10⁻⁴ · I + 0,12 µA f = 5 kHz to 10 kHz — 0,33 mA to 3,3 mA · CMC 47 · 10⁻⁴ · I + 0,44 µA f = 5 kHz to 10 kHz — 3,3 mA to 33 mA · CMC 48 · 10⁻⁴ · I + 2,2 µA f = 5 kHz to 10 kHz — 33 mA to 330 mA · CMC 48 · 10⁻⁴ · I + 22 µA AC current |
Direct and indirect method; At permanent location (S) | EURAMET cg-15 v.3.0 | |
| 16 | Clamp meters | Calibration — AC current f = 46 Hz to 65 Hz — 10 A to 16,5 A · CMC 23 · 10⁻⁴ · I + 3 mA f = 46 Hz to 65 Hz — 16,5 A to 150 A · CMC 24 · 10⁻⁴ · I + 22 mA f = 46 Hz to 65 Hz — 150 A to 550 A · CMC 22 · 10⁻⁴ · I + 90 mA f = 65 Hz to 440 Hz — 10 A to 16,5 A · CMC 54 · 10⁻⁴ · I + 11 mA f = 65 Hz to 440 Hz — 16,5 A to 150 A · CMC 65 · 10⁻⁴ · I + 22 mA f = 65 Hz to 440 Hz — 150 A to 550 A · CMC 62 · 10⁻⁴ · I + 62 mA AC current |
Internal procedure; Direct method; At permanent location (S) | E /I 2/ MAP | |
| 17 | Calibrators | Calibration — AC current f = 20 Hz to 45 Hz — 0,029 mA to 0,1 mA · CMC 18 · 10⁻⁴ · I + 34 nA f = 20 Hz to 45 Hz — 0,1 mA to 1 mA · CMC 18 · 10⁻⁴ · I + 0,22 µA f = 20 Hz to 45 Hz — 1 mA to 10 mA · CMC 18 · 10⁻⁴ · I + 2,2 µA f = 20 Hz to 45 Hz — 10 mA to 100 mA · CMC 18 · 10⁻⁴ · I + 22 µA f = 20 Hz to 45 Hz — 0,1 A to 1 A · CMC 19 · 10⁻⁴ · I + 0,23 mA f = 45 Hz to 100 Hz — 0,029 mA to 0,1 mA · CMC 64 · 10⁻⁵ · I + 36 nA f = 45 Hz to 100 Hz — 0,1 mA to 1 mA · CMC 69 · 10⁻⁵ · I + 0,23 µA f = 45 Hz to 100 Hz — 1 mA to 10 mA · CMC 69 · 10⁻⁵ · I + 2,3 µA f = 45 Hz to 100 Hz — 10 mA to 100 mA · CMC 69 · 10⁻⁵ · I + 23 µA f = 45 Hz to 100 Hz — 0,1 A to 1 A · CMC 98 · 10⁻⁵ · I + 0,22 mA f = 100 Hz to 5 kHz — 0,029 mA to 0,1 mA · CMC 64 · 10⁻⁵ · I + 36 nA f = 100 Hz to 5 kHz — 0,1 mA to 1 mA · CMC 34 · 10⁻⁵ · I + 0,24 µA f = 100 Hz to 5 kHz — 1 mA to 10 mA · CMC 34 · 10⁻⁵ · I + 2,4 µA f = 100 Hz to 5 kHz — 10 mA to 100 mA · CMC 34 · 10⁻⁵ · I + 24 µA f = 100 Hz to 5 kHz — 0,1 A to 1 A · CMC 12 · 10⁻⁴ · I + 0,23 mA f = 5 kHz to 10 kHz — 0,1 mA to 1 mA · CMC 69 · 10⁻⁵ · I + 0,23 µA f = 5 kHz to 10 kHz — 1 mA to 10 mA · CMC 69 · 10⁻⁵ · I + 2,3 µA f = 5 kHz to 10 kHz — 10 mA to 100 mA · CMC 69 · 10⁻⁵ · I + 23 µA f = 5 kHz to 10 kHz — 0,1 A to 1 A · CMC 35 · 10⁻⁴ · I + 0,23 mA AC current |
Direct and indirect method; At permanent location (S) | EURAMET cg-15 v.3.0 | |
| 18 | Calibrators | Calibration — AC current f = 45 Hz to 5 kHz — 5 mA to 1 A · CMC 12 · 10⁻⁴ · I + 0,4 mA f = 45 Hz to 5 kHz — 1 A to 2.2 A · CMC 95 · 10⁻⁵ · I + 3,2 mA f = 45 Hz to 5 kHz — 2.2 A to 3 A · CMC 63 · 10⁻⁴ · I + 2,1 mA AC current |
Direct method; Outside of permanent location (P) | EURAMET cg-15 v.3.0 | |
| 19 | Fixed resistors Variable resistors Shunts |
Calibration — DC resistance 10 µΩ to 100 µΩ · CMC 32 nΩ 100 µΩ to 1 mΩ · CMC 26· 10⁻⁵ · R + 30 nΩ 1 mΩ to 10 mΩ · CMC 20 · 10⁻⁵ · R 10 mΩ to 100 mΩ · CMC 20 · 10⁻⁶ · R 0,1 Ω to 1 Ω · CMC 5 · 10⁻⁶ · R 1 Ω to 10 kΩ · CMC 1 · 10⁻⁶ · R 10 kΩ to 100 kΩ · CMC 12 · 10⁻⁶ · R + 56 mΩ 0,1 MΩ to 1 MΩ · CMC 18 · 10⁻⁶ · R + 2,2 Ω 1 MΩ to 10 MΩ · CMC 59 · 10⁻⁶ · R + 0,11 kΩ 10 MΩ to 100 MΩ · CMC 58 · 10⁻⁵ · R + 1,2 kΩ 0,1 GΩ to 1 GΩ · CMC 58 · 10⁻⁴ · R + 10 MΩ DC resistance |
Internal procedure; Direct and indirect method; At permanent location (S) | E /I 3/ MAP | |
| 20 | Digital ohmmeters Multimeters Calibrators |
Calibration — DC resistance 10 µΩ to 100 µΩ · CMC 32 nΩ 100 µΩ to 1 mΩ · CMC 26· 10⁻⁵ · R + 30 nΩ 1 mΩ to 10 mΩ · CMC 20 · 10⁻⁵ · R 10 mΩ to 100 mΩ · CMC 20 · 10⁻⁶ · R 0,1 Ω to 1 Ω · CMC 5 · 10⁻⁶ · R 1 Ω to 10 kΩ · CMC 1 · 10⁻⁶ · R 10 kΩ to 100 kΩ · CMC 12 · 10⁻⁶ · R + 56 mΩ 0,1 MΩ to 1 MΩ · CMC 18 · 10⁻⁶ · R + 2,2 Ω 1 MΩ to 10 MΩ · CMC 59 · 10⁻⁶ · R + 0,11 kΩ 10 MΩ to 100 MΩ · CMC 58 · 10⁻⁵ · R + 1,2 kΩ 0,1 GΩ to 1 GΩ · CMC 58 · 10⁻⁴ · R + 10 MΩ DC resistance |
Direct and indirect method; At permanent location (S) | EURAMET cg-15 v.3.0 | |
| 21 | Analogue ohmmeters | Calibration — DC resistance 10 µΩ to 100 µΩ · CMC 32 nΩ 100 µΩ to 1 mΩ · CMC 26· 10⁻⁵ · R + 30 nΩ 1 mΩ to 10 mΩ · CMC 20 · 10⁻⁵ · R 10 mΩ to 100 mΩ · CMC 20 · 10⁻⁶ · R 0,1 Ω to 1 Ω · CMC 5 · 10⁻⁶ · R 1 Ω to 10 kΩ · CMC 1 · 10⁻⁶ · R 10 kΩ to 100 kΩ · CMC 12 · 10⁻⁶ · R + 56 mΩ 0,1 MΩ to 1 MΩ · CMC 18 · 10⁻⁶ · R + 2,2 Ω 1 MΩ to 10 MΩ · CMC 59 · 10⁻⁶ · R + 0,11 kΩ 10 MΩ to 100 MΩ · CMC 58 · 10⁻⁵ · R + 1,2 kΩ 0,1 GΩ to 1 GΩ · CMC 58 · 10⁻⁴ · R + 10 MΩ DC resistance |
Internal procedure; Direct method; At permanent location (S) | E /I 1/ MAP | |
| 22 | Fixed resistors Variable resistors |
Calibration — DC resistance 1 mΩ to 10 Ω · CMC 70 · 10⁻⁶ · R + 0,1 mΩ 10 Ω to 100 Ω · CMC 60 · 10⁻⁶ · R + 1,0 mΩ 100 Ω to 1 kΩ · CMC 58 · 10⁻⁶ · R + 2,3 mΩ 1 kΩ to 10 kΩ · CMC 58 · 10⁻⁶ · R + 23 mΩ 10 kΩ to 100 kΩ · CMC 80 · 10⁻⁶ · R + 0,47 Ω 100 kΩ to 1 MΩ · CMC 80 · 10⁻⁶ · R + 5,0 Ω 1 MΩ to 10 MΩ · CMC 46 · 10⁻⁵ · R + 48 Ω 10 MΩ to 100 MΩ · CMC 17 · 10⁻⁴ · R + 0,61 kΩ DC resistance |
Internal procedure; Direct method; Outside of permanent location (P) | E /I 3/ MAP P4 / MAP | |
| 23 | Calibrators Digital ohmmeters Multimeters |
Calibration — DC resistance 1 mΩ to 10 Ω · CMC 70 · 10⁻⁶ · R + 0,1 mΩ 10 Ω to 100 Ω · CMC 60 · 10⁻⁶ · R + 1,0 mΩ 100 Ω to 1 kΩ · CMC 58 · 10⁻⁶ · R + 2,3 mΩ 1 kΩ to 10 kΩ · CMC 58 · 10⁻⁶ · R + 23 mΩ 10 kΩ to 100 kΩ · CMC 80 · 10⁻⁶ · R + 0,47 Ω 100 kΩ to 1 MΩ · CMC 80 · 10⁻⁶ · R + 5,0 Ω 1 MΩ to 10 MΩ · CMC 46 · 10⁻⁵ · R + 48 Ω 10 MΩ to 100 MΩ · CMC 17 · 10⁻⁴ · R + 0,61 kΩ DC resistance |
Direct method; Outside of permanent location (P) | EURAMET cg-15 v.3.0 | |
| 24 | Analogue ohmmeters | Calibration — DC resistance 1 mΩ to 10 Ω · CMC 70 · 10⁻⁶ · R + 0,1 mΩ 10 Ω to 100 Ω · CMC 60 · 10⁻⁶ · R + 1,0 mΩ 100 Ω to 1 kΩ · CMC 58 · 10⁻⁶ · R + 2,3 mΩ 1 kΩ to 10 kΩ · CMC 58 · 10⁻⁶ · R + 23 mΩ 10 kΩ to 100 kΩ · CMC 80 · 10⁻⁶ · R + 0,47 Ω 100 kΩ to 1 MΩ · CMC 80 · 10⁻⁶ · R + 5,0 Ω 1 MΩ to 10 MΩ · CMC 46 · 10⁻⁵ · R + 48 Ω 10 MΩ to 100 MΩ · CMC 17 · 10⁻⁴ · R + 0,61 kΩ DC resistance |
Internal procedure; Direct method; Outside of permanent location (P) | E /I 1/ MAP P4 / MAP | |
| 25 | Digital active power meters | Calibration — DC power 0,33 V to 1000 V, 3,3 mA to 9 mA — 3 W to 9 W · CMC 0,046 · 10⁻² · w 0,33 V to 1000 V, 9 mA to 33 mA — 3 W to 33 W · CMC 0,034 · 10⁻² · w 0,33 V to 1000 V, 33 mA to 90 mA — 3 W to 90 W · CMC 0,047 · 10⁻² · w 0,33 V to 1000 V, 90 mA to 330 mA — 3 W to 330 W · CMC 0,034 · 10⁻² · w 0,33 V to 1000 V, 0,33 A to 0,9 A — 3 W to 900 W · CMC 0,092 · 10⁻² · w 0,33 V to 1000 V, 0,9 A to 2,2 A — 3 W to 2.2 kW · CMC 0,069 · 10⁻² · w 0,33 V to 1000 V, 2,2 A to 4,5 A — 3 W to 4,5 kW · CMC 0,14 · 10⁻² · w 0,33 V to 1000 V, 4,5 A to 11 A — 3 W to 11 kW · CMC 0,10 · 10⁻² · w DC power |
Internal procedure; At permanent location (S) | E /I 2/ MAP | |
| 26 | Digital active power meters single-phase |
Calibration — AC power f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 3,3 mA to 9 mA — 3 W to 9 W · CMC 0,29 · 10⁻² · w f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 9 mA to 33 mA — 3 W to 33 W · CMC 0,17 · 10⁻² · w f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 33 mA to 90 mA — 3 W to 90 W · CMC 0,29 · 10⁻² · w f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 90 mA to 330 mA — 3 W to 330 W · CMC 0,17 · 10⁻² · w f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 0,33 A to 0,9 A — 3 W to 900 W · CMC 0,29 · 10⁻² · w f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 0,9 A to 2,2 A — 3 W to 2.2 kW · CMC 0,17 · 10⁻² · w f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 2,2 A to 4,5 A — 3 W to 4,5 kW · CMC 0,23 · 10⁻² · w f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 4,5 A to 11 A — 3 W to 11 kW · CMC 0,17 · 10⁻² · w AC power |
Internal procedure; PF = 1; At permanent location (S) | E /I 2/ MAP | |
| 27 | Temperature indicators (meters) including temperature controllers Temperature transmitters Temperature recorders Temperature simulators |
Calibration — Electrical simulation of quantities -270 °C to 1820 °C · CMC 0,02 °C -200°C to 0 °C · CMC 0,002 °C 0°C to 850 °C · CMC 7 · 10⁻⁶ · t + 0,002 °C Electrical simulation of quantities |
Indirect electrical method; At permanent location (S) | EURAMET cg-11 v.2.0 | |
| 28 | Temperature indicators (meters) including temperature controllers Temperature transmitters Temperature recorders Temperature simulators |
Calibration — Electrical simulation of quantities -270°C to 1820 °C · CMC 0,2 °C -200°C to 850 °C · CMC 0,015 °C Electrical simulation of quantities |
Indirect electrical method; Outside of permanent location (P) | EURAMET cg-11 v.2.0 | |
| 29 | Time interval meters | Calibration — Time (time interval) 0 h to 24 h · CMC 0,35 s + 1 · 10⁻⁵ · τ Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | E /I 5/ MAP | |
| 30 | Time interval meters | Calibration — Time (time interval) 0 h to 24 h · CMC 0,35 s + 1 · 10⁻⁵ · τ Time (time interval) |
Internal procedure; Direct method; Outside of permanent location (P) | P4 / MAP E /I 5/ MAP | |
| 31 | Hygrometers | Calibration — Dew point temperature -20 °C dp to 20 °C dp · CMC 0,2 °C dp Dew point temperature |
Internal procedure; At permanent location (S) | W2/ MAP | |
| 32 | Hygrometers Thermohygrometers Psychrometers Transmitters |
Calibration — Relative humidity 37 %rh to 85 %rh — 37 %rh · CMC 1,0 %rh 37 %rh to 85 %rh — 85 %rh · CMC 1,7 %rh temperature — -20 °C to -5 °C · CMC 0,15 °C 20 %rh to 90 %rh — 20 %rh · CMC 1,0 %rh 20 %rh to 90 %rh — 90 %rh · CMC 1,7 %rh temperature — -5 °C to 0 °C · CMC 0,15 °C 10 %rh to 98 %rh · CMC 0,6 %rh temperature — 0 °C to 80 °C · CMC 0,15 °C 10 %rh to 98 %rh — 10 %rh · CMC 1,0 %rh 10 %rh to 98 %rh — 98 %rh · CMC 2,0 %rh temperature — 80 °C to 90 °C · CMC 0,15 °C Relative humidity |
Internal procedure; At permanent location (S) | W1/ MAP | |
| 33 | Climatic chambers | Calibration — Relative humidity 20 %rh to 98 %rh · CMC 2,0 %rh 1) temperature — 0 °C to 10 °C · CMC 0,20 °C 1) 10 %rh to 98 %rh · CMC 2,0 %rh 1) temperature — 10 °C to 80 °C · CMC 0,20 °C 1) 10 %rh to 98 %rh · CMC 2,5 %rh 1) temperature — 80 °C to 90 °C · CMC 0,20 °C 1) Relative humidity |
Internal procedure; At permanent location (S) and outside of it (P) | T /I 11/ MAP P4 / MAP | |
| 34 | Hygrometers Thermohygrometers Psychrometers Transmitters |
Calibration — Relative humidity 10 %rh to 98 %rh · CMC 2,0 %rh temperature — 10 °C to 80 °C · CMC 0,20 °C 20 %rh to 98 %rh · CMC 2,0 %rh temperature — 0 °C to 10 °C · CMC 0,20 °C Relative humidity |
Internal procedure; Outside of permanent location (P) | W1/ MAP P4 / MAP | |
| 35 | Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters - gauge pressure: negative and positive pressure (gas medium) |
Calibration — Pressure -0,1 MPa to -0,09 MPa · CMC 3 · 10⁻⁴ · p + 255 Pa -0,09 MPa to -0,015 MPa · CMC 16 Pa -0,015 MPa to -0,009 MPa · CMC 1 · 10⁻⁴ · p + 0,01 Pa -0,009 MPa to 0,009 MPa · CMC 0,9 Pa 0,009 MPa to 0,015 MPa · CMC 1 · 10⁻⁴ · p + 0,01 Pa 0,015 MPa to 0,1 MPa · CMC 16 Pa 0,1 MPa to 0,6 MPa · CMC 60,3 Pa 0,6 MPa to 2 MPa · CMC 1 · 10⁻⁴ · p + 1 Pa Pressure |
Internal procedure; At permanent location (S) | C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP based on EURAMET cg-17 v.4.1 | |
| 36 | Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters - absolute pressure (gas medium) |
Calibration — Pressure 25 hPa to 100 hPa · CMC 3 · 10⁻⁴ · p + 270 Pa 100 hPa to 600 hPa · CMC 17,3 Pa 600 hPa to 2000 hPa · CMC 6 · 10⁻⁵ · p + 14 Pa 2000 hPa to 6000 hPa · CMC 63,5 Pa 6000 hPa to 20000 hPa · CMC 1 · 10⁻⁴ · p + 4 Pa 20000 hPa to 21000 hPa · CMC 3 · 10⁻⁴ · p + 270 Pa Pressure |
Internal procedure; At permanent location (S) | C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP based on EURAMET cg-17 v.4.1 | |
| 37 | Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters - gauge pressure: negative and positive pressure (gas medium) |
Calibration — Pressure -0,1 MPa to -0,04 MPa · CMC 3 · 10⁻⁴ · p + 255 Pa -0,04 MPa to 0,04 MPa · CMC 4 · 10⁻⁴ · p + 22,4 Pa 0,04 MPa to 2 MPa · CMC 3 · 10⁻⁴ · p + 255 Pa -2500 Pa to 2500 Pa · CMC 1,3 Pa Pressure |
Internal procedure; Outside of permanent location (P) | C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP | |
| 38 | Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters - absolute pressure (gas medium) |
Calibration — Pressure 25 hPa to 600 hPa · CMC 3 · 10⁻⁴ · p + 270 Pa 600 hPa to 800 hPa · CMC 70 Pa 800 hPa to 1200 hPa · CMC 60 Pa 1200 hPa to 1400 hPa · CMC 70 Pa 1400 hPa to 21000 hPa · CMC 3 · 10⁻⁴ · p + 270 Pa Pressure |
Internal procedure; Outside of permanent location (P) | C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP | |
| 39 | Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters - gauge pressure: positive pressure (oil) |
Calibration — Pressure 0,02 MPa do 0,06 MPa · CMC 25 Pa 0,06 MPa do 0,6 MPa · CMC 4 · 10⁻⁴ · p + 46 Pa 0,6 MPa to 6 MPa · CMC 18 · 10⁻⁵ · p + 550 Pa 6 MPa to 25 MPa · CMC 4 · 10⁻⁴ · p + 4500 Pa 25 MPa do 60 MPa · CMC 4 · 10⁻⁴ · p + 7000 Pa Pressure |
Internal procedure; At permanent location (S) | C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP | |
| 40 | Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters - gauge pressure: positive pressure (oil) |
Calibration — Pressure 0 MPa to 6 MPa · CMC 7000 Pa 6 MPa to 20 MPa · CMC 4 · 10⁻⁴ · p + 7000 Pa Pressure |
Internal procedure; Outside of permanent location (P) | C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP | |
| 41 | Noble metal thermocouples Base metal thermocouples |
Calibration — Temperature (electrical thermometry) -80 °C do 250 °C · CMC 0,35 °C 250 °C do 1085 °C · CMC 0,6 °C 1085 °C to 1200 °C · CMC 0,8 °C 1200 °C to 1300 °C · CMC 1,3 °C 1300 °C do 1450 °C · CMC 1,8 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) | T /I 1/ MAP based on EURAMET cg-8 v. 3.1 | |
| 42 | Noble metal thermocouples Base metal thermocouples |
Calibration — Temperature (electrical thermometry) -30 °C to 110 °C · CMC 0,5 °C 110 °C to 660 °C · CMC 1,0 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; Outside of permanent location (P) | T /I 1/ MAP P4 / MAP | |
| 43 | Resistance thermometer sensors | Calibration — Temperature (electrical thermometry) -80 °C to -40 °C · CMC 0,02 °C -40 °C to 250 °C · CMC 0,01 °C 250 °C to 660 °C · CMC 0,12 °C 0,01 °C · CMC 0,005 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) | T /I 2/ MAP | |
| 44 | Resistance thermometer sensors | Calibration — Temperature (electrical thermometry) -30 °C to 110 °C · CMC 0,03 °C 110 °C to 660 °C · CMC 0,15 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; Outside of permanent location (P) | T /I 2/ MAP P4 / MAP | |
| 45 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Temperature transmitters (containing temperature sensors) |
Calibration — Temperature (electrical thermometry) -80 °C do -40 °C · CMC 0,02 °C -40 °C do 250 °C · CMC 0,01 °C 250 °C do 660 °C · CMC 0,12 °C 660 °C do 1085 °C · CMC 0,5 °C 1085 °C to 1200 °C · CMC 0,8 °C 1200 °C to 1300 °C · CMC 1,3 °C 1300 °C do 1450 °C · CMC 1,8 °C 0,01 °C · CMC 0,005 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) | T /I 9/ MAP | |
| 46 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Temperature transmitters (containing temperature sensors) |
Calibration — Temperature (electrical thermometry) -30 °C to 110 °C · CMC 0,03 °C 110 °C to 650 °C · CMC 0,15 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; Outside of permanent location (P) | T /I 9/ MAP P4 / MAP | |
| 47 | Liquid baths | Calibration — Temperature (electrical thermometry) -80 °C to 250 °C · CMC 0,02 °C 1) Temperature (electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) | T /I 10/ MAP T /I 14/ MAP | |
| 48 | Liquid baths | Calibration — Temperature (electrical thermometry) -80 °C to 250 °C · CMC 0,03 °C 1) Temperature (electrical thermometry) |
Internal procedure; Direct method; Outside of permanent location (P) | T /I 10/ MAP T /I 14/ MAP P4 / MAP | |
| 49 | Temperature calibrators | Calibration — Temperature (electrical thermometry) -50 °C to 660 °C · CMC 0,12 °C 1) 660 °C to 1200 °C · CMC 0,6 °C 1) Temperature (electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | T /I 12/ MAP P4 / MAP based on EURAMET cg-13 v. 4.0 | |
| 50 | Furnaces | Calibration — Temperature (electrical thermometry) 100 °C to 420 °C · CMC 0,6 °C 1) 420 °C to 950 °C · CMC 1,5 °C 1) 950 °C to 1200 °C · CMC 2,0 °C 1) 1200 °C to 1450 °C · CMC 3,0 °C 1) Temperature (electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | T /I 10/ MAP P4 / MAP | |
| 51 | Climatic chambers Thermostatic chambers |
Calibration — Temperature (electrical thermometry) -80 °C to 250 °C · CMC 0,20 °C 1) 250 °C to 420 °C · CMC 0,6 °C 1) Temperature (electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | T /I 11/ MAP P4 / MAP based on EURAMET cg-20 v. 5.0 | |
| 52 | Steam sterilization chambers (including autoclaves) |
Calibration — Temperature (electrical thermometry) 100 °C to 150 °C · CMC 0,3 °C 1) Temperature (electrical thermometry) |
Internal procedure; Direct method; Outside of permanent location (P) | T /I 10/ MAP P4 / MAP | |
| 53 | Dial thermometers (pressure-spring, expansion and bimetallic) |
Calibration — Temperature (non-electrical thermometry) -30 °C to 420 °C · CMC 0,10 °C 420 °C to 650 °C · CMC 0,5 °C Temperature (non-electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) | T /I 9/ MAP | |
| 54 | Liquid-in-glass thermometers | Calibration — Temperature (non-electrical thermometry) -80 °C to 100 °C · CMC 0,03 °C 100 °C to 250 °C · CMC 0,04 °C Temperature (non-electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) | T /I 8/ MAP | |
| 55 | Radiation pyrometers Photoelectric pyrometers Thermal imaging cameras |
Calibration — Temperature (radiation thermometry) -15 °C do 0 °C · CMC 1,6 °C 0 °C do 50 °C · CMC 1,4 °C 50 °C do 100 °C · CMC 1,8 °C 100 °C to 200 °C · CMC 2,3 °C 200 °C do 350 °C · CMC 3,0 °C 350 °C do 500 °C · CMC 3,9 °C Temperature (radiation thermometry) |
Internal procedure; Direct method; At permanent location (S) | T /I 13/ MAP | |
Reference standards (25)
C /I 1/ MAP
C /I 2/ MAP
C /I 3/ MAP
E /I 1/ MAP
E /I 2/ MAP
E /I 3/ MAP
E /I 5/ MAP
EURAMET cg-11 v.2.0
EURAMET cg-13 v. 4.0
EURAMET cg-15 v.3.0
EURAMET cg-17 v.4.1
EURAMET cg-20 v. 5.0
EURAMET cg-8 v. 3.1
P4 / MAP
T /I 1/ MAP
T /I 10/ MAP
T /I 11/ MAP
T /I 12/ MAP
T /I 13/ MAP
T /I 14/ MAP
T /I 2/ MAP
T /I 8/ MAP
T /I 9/ MAP
W1/ MAP
W2/ MAP