{"lab":{"_id":"6afad8068989a133b76447bf","accr_number":"AP 013","country":"PL","imported_at":"2026-11-16T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Augustówka 36, 02-981 Warszawa","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"09.01.2024","city":"Warszawa","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. The value of the uncertainty covered by the CMC expressed as a percentage is the relative measurement uncertainty and refers to the percentage share of the value of the measurand.","cycle_from":"03.08.2023","cycle_to":"02.09.2027","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"7.01","pl":"napięcie DC","en":"DC voltage","de":"Gleichspannung","zh":"直流电压","cs":"stejnosměrné napětí (DC)"},{"codes":"7.02","pl":"prąd DC","en":"DC current","de":"DC-Strom","zh":"直流电流","cs":"proud DC"},{"codes":"7.03","pl":"napięcie AC","en":"AC voltage","de":"AC-Spannung","zh":"交流电压","cs":"napětí AC"},{"codes":"7.04","pl":"prąd AC","en":"AC current","de":"AC-Strom","zh":"交流电流","cs":"proud AC"},{"codes":"7.05","pl":"rezystancja DC","en":"DC resistance","de":"DC-Widerstand","zh":"直流电阻","cs":"odpor DC"},{"codes":"7.12","pl":"moc DC","en":"DC power","de":"DC-Leistung","zh":"直流功率","cs":"stejnosměrný výkon"},{"codes":"7.13","pl":"moc AC","en":"AC power","de":"AC-Leistung","zh":"交流功率","cs":"výkon AC"},{"codes":"7.15","pl":"elektryczna symulacja wielkości","en":"electrical simulation of quantities","de":"elektrische Simulation von Größen","zh":"量值的电模拟","cs":"elektrická simulace veličin"},{"codes":"10.01","pl":"czas (przedział czasu)","en":"time (time interval)","de":"Zeit (Zeitintervall)","zh":"时间（时间间隔）","cs":"čas (časový interval)"},{"codes":"14.01","pl":"temperatura punktu rosy","en":"dew point temperature","de":"Taupunkttemperatur","zh":"露点温度","cs":"teplota rosného bodu"},{"codes":"14.02","pl":"wilgotność względna","en":"relative humidity","de":"relative Feuchte","zh":"相对湿度","cs":"relativní vlhkost"},{"codes":"17.01","pl":"ciśnienie","en":"pressure","de":"Druck","zh":"压力","cs":"tlak"},{"codes":"19.01","pl":"temperatura (termometria elektryczna)","en":"temperature (electrical thermometry)","de":"Temperatur (elektrische Thermometrie)","zh":"温度（电测温）","cs":"teplota (elektrická termometrie)"},{"codes":"19.02","pl":"temperatura (termometria nieelektryczna)","en":"temperature (non-electrical thermometry)","de":"Temperatur (nichtelektrische Thermometrie)","zh":"温度（非电测温）","cs":"teplota (neelektrická termometrie)"},{"codes":"19.03","pl":"temperatura (termometria radiacyjna)","en":"temperature (radiation thermometry)","de":"Temperatur (Strahlungsthermometrie)","zh":"温度（辐射测温）","cs":"teplota (radiační termometrie)"}],"has_en":true,"has_zh":true,"issue":{"no":"23","date":"17.07.2026"},"issue_date":"17.07.2026","issue_number":"23","lab_division":"Laboratorium Aparatury Pomiarowej","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[21.0861208,52.1936384]},"map_coord":[52.1936384,21.0861208],"map_geo":"nominatim-street","methods_count":55,"name":"Instytut Energetyki - Państwowy Instytut Badawczy","parse_date":"2026-11-16T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-16T12:00:00.000Z","pdf_files":["AP_013.pdf"],"scope_notes":[{"pl":"1) Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni obiektu wzorcowania.","en":"1) The value of the uncertainty covered by the CMC refers to a single measuring point in the space of the calibrated object."}],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: napięcie DC, prąd DC, napięcie AC, prąd AC, rezystancja DC, moc DC, moc AC, elektryczna symulacja wielkości, czas (przedział czasu), temperatura punktu rosy, wilgotność względna, ciśnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna), temperatura (termometria radiacyjna). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"instytut energetyki - państwowy instytut badawczy laboratorium aparatury pomiarowej ul. augustówka 36, 02-981 warszawa laboratorium wzorcujące. wielkości mierzone: napięcie dc, prąd dc, napięcie ac, prąd ac, rezystancja dc, moc dc, moc ac, elektryczna symulacja wielkości, czas (przedział czasu), temperatura punktu rosy, wilgotność względna, ciśnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna), temperatura (termometria radiacyjna). w stałej lokalizacji (s) i/lub poza nią (p). ap 013 ap013 laboratorium wzorcujące wzorcowanie kalibracja dc voltage dc current ac voltage ac current dc resistance dc power ac power electrical simulation of quantities time (time interval) dew point temperature relative humidity pressure temperature (electrical thermometry) temperature (non-electrical thermometry) temperature (radiation thermometry) instytut energetyki - panstwowy instytut badawczy laboratorium aparatury pomiarowej ul. augustowka 36, 02-981 warszawa laboratorium wzorcujace. wielkosci mierzone: napiecie dc, prad dc, napiecie ac, prad ac, rezystancja dc, moc dc, moc ac, elektryczna symulacja wielkosci, czas (przedzial czasu), temperatura punktu rosy, wilgotnosc wzgledna, cisnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna), temperatura (termometria radiacyjna). w stalej lokalizacji (s) i/lub poza nia (p). ap 013 ap013 laboratorium wzorcujace wzorcowanie kalibracja dc voltage dc current ac voltage ac current dc resistance dc power ac power electrical simulation of quantities time (time interval) dew point temperature relative humidity pressure temperature (electrical thermometry) temperature (non-electrical thermometry) temperature (radiation thermometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20013,podmiot.html","source_pdf_sha256":"ace6bf56597737b146c2703cf0f2b3353c40af8cac39871980e1bc9a7dd52c6e","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/16/bf042e6dbda45fceea1bfbfdf51c6d31/AP%20013.pdf","status":"active","updated_at":"2026-11-16T12:00:00.000Z","valid_from":"03-09-1999","valid_until":"02-09-2027","website":"www.ien.com.pl","lab_division_en":"Measuring Equipment Laboratory","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"lab_division_de":"Labor für Messgeräte","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","lab_division_zh":"测量仪器实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"lab_division_cs":"Laboratoř měřicích přístrojů","pelny_cs":true},"methods":[{"_id":"310d94c43b8b57e6e16fddf4","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki napięcia analogowe","test_object_en":"Analogue voltmeters","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0 µV do 100 mV","cmc":"5 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"100 mV do 1 V","cmc":"4 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"1 V do 10 V","cmc":"4 · 10⁻⁶ · U + 5 µV"},{"name":"","range":"10 V do 100 V","cmc":"7 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V do 1000 V","cmc":"8 · 10⁻⁶ · U + 0,1 mV"}],"parameters_en":[{"name":"","range":"0 µV to 100 mV","cmc":"5 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"100 mV to 1 V","cmc":"4 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"1 V to 10 V","cmc":"4 · 10⁻⁶ · U + 5 µV"},{"name":"","range":"10 V to 100 V","cmc":"7 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"8 · 10⁻⁶ · U + 0,1 mV"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0 µV do 100 mV CMC 5 · 10⁻⁶ · U + 0,5 µV\n100 mV do 1 V CMC 4 · 10⁻⁶ · U + 0,5 µV\n1 V do 10 V CMC 4 · 10⁻⁶ · U + 5 µV\n10 V do 100 V CMC 7 · 10⁻⁶ · U + 30 µV\n100 V do 1000 V CMC 8 · 10⁻⁶ · U + 0,1 mV\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"E /I 1/ MAP","norm_bases":["E /I 1/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":"U – wielkość mierzona (V)","note_en":"U – measured value (V)","search_text":"Mierniki napięcia analogowe Wzorcowanie — Napięcie DC\nZakres:\n0 µV do 100 mV CMC 5 · 10⁻⁶ · U + 0,5 µV\n100 mV do 1 V CMC 4 · 10⁻⁶ · U + 0,5 µV\n1 V do 10 V CMC 4 · 10⁻⁶ · U + 5 µV\n10 V do 100 V CMC 7 · 10⁻⁶ · U + 30 µV\n100 V do 1000 V CMC 8 · 10⁻⁶ · U + 0,1 mV\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) E /I 1/ MAP Mierniki napiecia analogowe Wzorcowanie — Napiecie DC\nZakres:\n0 µV do 100 mV CMC 5 · 10⁻⁶ · U + 0,5 µV\n100 mV do 1 V CMC 4 · 10⁻⁶ · U + 0,5 µV\n1 V do 10 V CMC 4 · 10⁻⁶ · U + 5 µV\n10 V do 100 V CMC 7 · 10⁻⁶ · U + 30 µV\n100 V do 1000 V CMC 8 · 10⁻⁶ · U + 0,1 mV\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) E /I 1/ MAP","search_en":"Analogue voltmeters Calibration — DC voltage Internal procedure; Direct method; At permanent location (S) DC voltage Internal procedure Direct method At permanent location (S) E /I 1/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0 µV to 100 mV","cmc":"5 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"100 mV to 1 V","cmc":"4 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"1 V to 10 V","cmc":"4 · 10⁻⁶ · U + 5 µV"},{"name":"","range":"10 V to 100 V","cmc":"7 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"8 · 10⁻⁶ · U + 0,1 mV"}],"regulatory_area_de":"DC-Spannung","search_de":"Analoge Spannungsmessgeräte Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) E /I 1/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Spannungsmessgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0 µV to 100 mV","cmc":"5 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"100 mV to 1 V","cmc":"4 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"1 V to 10 V","cmc":"4 · 10⁻⁶ · U + 5 µV"},{"name":"","range":"10 V to 100 V","cmc":"7 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"8 · 10⁻⁶ · U + 0,1 mV"}],"regulatory_area_zh":"直流电压","search_zh":"模拟电压表 校准 — 直流电压 内部程序；直接法；在固定地点 (S) 直流电压 内部程序 直接法 在固定地点 (S) E /I 1/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"模拟电压表","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0 µV to 100 mV","cmc":"5 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"100 mV to 1 V","cmc":"4 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"1 V to 10 V","cmc":"4 · 10⁻⁶ · U + 5 µV"},{"name":"","range":"10 V to 100 V","cmc":"7 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"8 · 10⁻⁶ · U + 0,1 mV"}],"regulatory_area_cs":"Napětí DC","search_cs":"Analogové měřiče napětí Kalibrace — Napětí DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Napětí DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) E /I 1/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče napětí"},{"_id":"9e18f089949f7e0f6288b6c5","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki napięcia cyfrowe\nMultimetry\nKalibratory\nZasilacze","test_object_en":"Digital voltmeters\nMultimeters\nCalibrators\nPower supplies","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0 µV do 100 mV","cmc":"5 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"100 mV do 1 V","cmc":"4 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"1 V do 10 V","cmc":"4 · 10⁻⁶ · U + 5 µV"},{"name":"","range":"10 V do 100 V","cmc":"7 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V do 1000 V","cmc":"8 · 10⁻⁶ · U + 0,1 mV"}],"parameters_en":[{"name":"","range":"0 µV to 100 mV","cmc":"5 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"100 mV to 1 V","cmc":"4 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"1 V to 10 V","cmc":"4 · 10⁻⁶ · U + 5 µV"},{"name":"","range":"10 V to 100 V","cmc":"7 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"8 · 10⁻⁶ · U + 0,1 mV"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","technique_en":"Direct and indirect method; At permanent location (S)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Direct and indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0 µV do 100 mV CMC 5 · 10⁻⁶ · U + 0,5 µV\n100 mV do 1 V CMC 4 · 10⁻⁶ · U + 0,5 µV\n1 V do 10 V CMC 4 · 10⁻⁶ · U + 5 µV\n10 V do 100 V CMC 7 · 10⁻⁶ · U + 30 µV\n100 V do 1000 V CMC 8 · 10⁻⁶ · U + 0,1 mV\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":"U – wielkość mierzona (V)","note_en":"U – measured value (V)","search_text":"Mierniki napięcia cyfrowe\nMultimetry\nKalibratory\nZasilacze Wzorcowanie — Napięcie DC\nZakres:\n0 µV do 100 mV CMC 5 · 10⁻⁶ · U + 0,5 µV\n100 mV do 1 V CMC 4 · 10⁻⁶ · U + 0,5 µV\n1 V do 10 V CMC 4 · 10⁻⁶ · U + 5 µV\n10 V do 100 V CMC 7 · 10⁻⁶ · U + 30 µV\n100 V do 1000 V CMC 8 · 10⁻⁶ · U + 0,1 mV\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) EURAMET cg-15 v.3.0 Mierniki napiecia cyfrowe\nMultimetry\nKalibratory\nZasilacze Wzorcowanie — Napiecie DC\nZakres:\n0 µV do 100 mV CMC 5 · 10⁻⁶ · U + 0,5 µV\n100 mV do 1 V CMC 4 · 10⁻⁶ · U + 0,5 µV\n1 V do 10 V CMC 4 · 10⁻⁶ · U + 5 µV\n10 V do 100 V CMC 7 · 10⁻⁶ · U + 30 µV\n100 V do 1000 V CMC 8 · 10⁻⁶ · U + 0,1 mV\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) EURAMET cg-15 v.3.0","search_en":"Digital voltmeters Multimeters Calibrators Power supplies Calibration — DC voltage Direct and indirect method; At permanent location (S) DC voltage Direct and indirect method At permanent location (S) EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0 µV to 100 mV","cmc":"5 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"100 mV to 1 V","cmc":"4 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"1 V to 10 V","cmc":"4 · 10⁻⁶ · U + 5 µV"},{"name":"","range":"10 V to 100 V","cmc":"7 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"8 · 10⁻⁶ · U + 0,1 mV"}],"regulatory_area_de":"DC-Spannung","search_de":"Digitale Spannungsmessgeräte Multimeter Kalibratoren Netzgeräte Kalibrierung — DC-Spannung Direktes und indirektes Verfahren; Am festen Standort (S) DC-Spannung Direktes und indirektes Verfahren Am festen Standort (S) EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Spannungsmessgeräte\nMultimeter\nKalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0 µV to 100 mV","cmc":"5 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"100 mV to 1 V","cmc":"4 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"1 V to 10 V","cmc":"4 · 10⁻⁶ · U + 5 µV"},{"name":"","range":"10 V to 100 V","cmc":"7 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"8 · 10⁻⁶ · U + 0,1 mV"}],"regulatory_area_zh":"直流电压","search_zh":"数字电压表 万用表 校准器 电源 校准 — 直流电压 直接法和间接法; 在固定地点 (S) 直流电压 直接法和间接法 在固定地点 (S) EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法; 在固定地点 (S)","techniques_zh":["直接法和间接法","在固定地点 (S)"],"test_object_zh":"数字电压表\n万用表\n校准器\n电源","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0 µV to 100 mV","cmc":"5 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"100 mV to 1 V","cmc":"4 · 10⁻⁶ · U + 0,5 µV"},{"name":"","range":"1 V to 10 V","cmc":"4 · 10⁻⁶ · U + 5 µV"},{"name":"","range":"10 V to 100 V","cmc":"7 · 10⁻⁶ · U + 30 µV"},{"name":"","range":"100 V to 1000 V","cmc":"8 · 10⁻⁶ · U + 0,1 mV"}],"regulatory_area_cs":"Napětí DC","search_cs":"Digitální měřiče napětí Multimetry Kalibrátory Napájecí zdroje Kalibrace — Napětí DC Přímá a nepřímá metoda; Ve stálé lokalitě (S) Napětí DC Přímá a nepřímá metoda Ve stálé lokalitě (S) EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Přímá a nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální měřiče napětí\nMultimetry\nKalibrátory\nNapájecí zdroje"},{"_id":"d1d7ebde0c07edc0c1236100","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki napięcia analogowe","test_object_en":"Analogue voltmeters","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0 µV do 100 mV","cmc":"42 · 10⁻⁶ · U + 1,1 µV"},{"name":"","range":"100 mV do 1 V","cmc":"29 · 10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V do 10 V","cmc":"28 · 10⁻⁶ · U + 40 µV"},{"name":"","range":"10 V do 100 V","cmc":"40 · 10⁻⁶ · U + 0,6 mV"},{"name":"","range":"100 V do 1000 V","cmc":"47 · 10⁻⁶ · U + 7 mV"}],"parameters_en":[{"name":"","range":"0 µV to 100 mV","cmc":"42 · 10⁻⁶ · U + 1,1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"29 · 10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"28 · 10⁻⁶ · U + 40 µV"},{"name":"","range":"10 V to 100 V","cmc":"40 · 10⁻⁶ · U + 0,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"47 · 10⁻⁶ · U + 7 mV"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0 µV do 100 mV CMC 42 · 10⁻⁶ · U + 1,1 µV\n100 mV do 1 V CMC 29 · 10⁻⁶ · U + 2 µV\n1 V do 10 V CMC 28 · 10⁻⁶ · U + 40 µV\n10 V do 100 V CMC 40 · 10⁻⁶ · U + 0,6 mV\n100 V do 1000 V CMC 47 · 10⁻⁶ · U + 7 mV\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"E /I 1/ MAP\nP4 / MAP","norm_bases":["E /I 1/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"P","note":"U – wielkość mierzona (V)","note_en":"U – measured value (V)","search_text":"Mierniki napięcia analogowe Wzorcowanie — Napięcie DC\nZakres:\n0 µV do 100 mV CMC 42 · 10⁻⁶ · U + 1,1 µV\n100 mV do 1 V CMC 29 · 10⁻⁶ · U + 2 µV\n1 V do 10 V CMC 28 · 10⁻⁶ · U + 40 µV\n10 V do 100 V CMC 40 · 10⁻⁶ · U + 0,6 mV\n100 V do 1000 V CMC 47 · 10⁻⁶ · U + 7 mV\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) E /I 1/ MAP\nP4 / MAP Mierniki napiecia analogowe Wzorcowanie — Napiecie DC\nZakres:\n0 µV do 100 mV CMC 42 · 10⁻⁶ · U + 1,1 µV\n100 mV do 1 V CMC 29 · 10⁻⁶ · U + 2 µV\n1 V do 10 V CMC 28 · 10⁻⁶ · U + 40 µV\n10 V do 100 V CMC 40 · 10⁻⁶ · U + 0,6 mV\n100 V do 1000 V CMC 47 · 10⁻⁶ · U + 7 mV\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) E /I 1/ MAP\nP4 / MAP","search_en":"Analogue voltmeters Calibration — DC voltage Internal procedure; Direct method; Outside of permanent location (P) DC voltage Internal procedure Direct method Outside of permanent location (P) E /I 1/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0 µV to 100 mV","cmc":"42 · 10⁻⁶ · U + 1,1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"29 · 10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"28 · 10⁻⁶ · U + 40 µV"},{"name":"","range":"10 V to 100 V","cmc":"40 · 10⁻⁶ · U + 0,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"47 · 10⁻⁶ · U + 7 mV"}],"regulatory_area_de":"DC-Spannung","search_de":"Analoge Spannungsmessgeräte Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) DC-Spannung Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) E /I 1/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Analoge Spannungsmessgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0 µV to 100 mV","cmc":"42 · 10⁻⁶ · U + 1,1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"29 · 10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"28 · 10⁻⁶ · U + 40 µV"},{"name":"","range":"10 V to 100 V","cmc":"40 · 10⁻⁶ · U + 0,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"47 · 10⁻⁶ · U + 7 mV"}],"regulatory_area_zh":"直流电压","search_zh":"模拟电压表 校准 — 直流电压 内部程序；直接法；固定地点以外 (P) 直流电压 内部程序 直接法 固定地点以外 (P) E /I 1/ MAP P4 / MAP","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"模拟电压表","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0 µV to 100 mV","cmc":"42 · 10⁻⁶ · U + 1,1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"29 · 10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"28 · 10⁻⁶ · U + 40 µV"},{"name":"","range":"10 V to 100 V","cmc":"40 · 10⁻⁶ · U + 0,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"47 · 10⁻⁶ · U + 7 mV"}],"regulatory_area_cs":"Napětí DC","search_cs":"Analogové měřiče napětí Kalibrace — Napětí DC Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Napětí DC Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) E /I 1/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Analogové měřiče napětí"},{"_id":"21dc8f07fe664005332bd4a3","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki napięcia cyfrowe\nMultimetry\nKalibratory\nZasilacze","test_object_en":"Digital voltmeters\nMultimeters\nCalibrators\nPower supplies","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0 µV do 100 mV","cmc":"42 · 10⁻⁶ · U + 1,1 µV"},{"name":"","range":"100 mV do 1 V","cmc":"29 · 10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V do 10 V","cmc":"28 · 10⁻⁶ · U + 40 µV"},{"name":"","range":"10 V do 100 V","cmc":"40 · 10⁻⁶ · U + 0,6 mV"},{"name":"","range":"100 V do 1000 V","cmc":"47 · 10⁻⁶ · U + 7 mV"}],"parameters_en":[{"name":"","range":"0 µV to 100 mV","cmc":"42 · 10⁻⁶ · U + 1,1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"29 · 10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"28 · 10⁻⁶ · U + 40 µV"},{"name":"","range":"10 V to 100 V","cmc":"40 · 10⁻⁶ · U + 0,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"47 · 10⁻⁶ · U + 7 mV"}],"technique":"Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Direct method; Outside of permanent location (P)","techniques":["Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0 µV do 100 mV CMC 42 · 10⁻⁶ · U + 1,1 µV\n100 mV do 1 V CMC 29 · 10⁻⁶ · U + 2 µV\n1 V do 10 V CMC 28 · 10⁻⁶ · U + 40 µV\n10 V do 100 V CMC 40 · 10⁻⁶ · U + 0,6 mV\n100 V do 1000 V CMC 47 · 10⁻⁶ · U + 7 mV\nMetoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"P","note":"U – wielkość mierzona (V)","note_en":"U – measured value (V)","search_text":"Mierniki napięcia cyfrowe\nMultimetry\nKalibratory\nZasilacze Wzorcowanie — Napięcie DC\nZakres:\n0 µV do 100 mV CMC 42 · 10⁻⁶ · U + 1,1 µV\n100 mV do 1 V CMC 29 · 10⁻⁶ · U + 2 µV\n1 V do 10 V CMC 28 · 10⁻⁶ · U + 40 µV\n10 V do 100 V CMC 40 · 10⁻⁶ · U + 0,6 mV\n100 V do 1000 V CMC 47 · 10⁻⁶ · U + 7 mV\nMetoda bezpośrednia; Poza stałą lokalizacją (P) EURAMET cg-15 v.3.0 Mierniki napiecia cyfrowe\nMultimetry\nKalibratory\nZasilacze Wzorcowanie — Napiecie DC\nZakres:\n0 µV do 100 mV CMC 42 · 10⁻⁶ · U + 1,1 µV\n100 mV do 1 V CMC 29 · 10⁻⁶ · U + 2 µV\n1 V do 10 V CMC 28 · 10⁻⁶ · U + 40 µV\n10 V do 100 V CMC 40 · 10⁻⁶ · U + 0,6 mV\n100 V do 1000 V CMC 47 · 10⁻⁶ · U + 7 mV\nMetoda bezposrednia; Poza stala lokalizacja (P) EURAMET cg-15 v.3.0","search_en":"Digital voltmeters Multimeters Calibrators Power supplies Calibration — DC voltage Direct method; Outside of permanent location (P) DC voltage Direct method Outside of permanent location (P) EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0 µV to 100 mV","cmc":"42 · 10⁻⁶ · U + 1,1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"29 · 10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"28 · 10⁻⁶ · U + 40 µV"},{"name":"","range":"10 V to 100 V","cmc":"40 · 10⁻⁶ · U + 0,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"47 · 10⁻⁶ · U + 7 mV"}],"regulatory_area_de":"DC-Spannung","search_de":"Digitale Spannungsmessgeräte Multimeter Kalibratoren Netzgeräte Kalibrierung — DC-Spannung Direktes Verfahren; Außerhalb des festen Standorts (P) DC-Spannung Direktes Verfahren Außerhalb des festen Standorts (P) EURAMET cg-15 v.3.0","technique_de":"Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Digitale Spannungsmessgeräte\nMultimeter\nKalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0 µV to 100 mV","cmc":"42 · 10⁻⁶ · U + 1,1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"29 · 10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"28 · 10⁻⁶ · U + 40 µV"},{"name":"","range":"10 V to 100 V","cmc":"40 · 10⁻⁶ · U + 0,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"47 · 10⁻⁶ · U + 7 mV"}],"regulatory_area_zh":"直流电压","search_zh":"数字电压表 万用表 校准器 电源 校准 — 直流电压 直接法；固定地点以外 (P) 直流电压 直接法 固定地点以外 (P) EURAMET cg-15 v.3.0","technique_zh":"直接法；固定地点以外 (P)","techniques_zh":["直接法","固定地点以外 (P)"],"test_object_zh":"数字电压表\n万用表\n校准器\n电源","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0 µV to 100 mV","cmc":"42 · 10⁻⁶ · U + 1,1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"29 · 10⁻⁶ · U + 2 µV"},{"name":"","range":"1 V to 10 V","cmc":"28 · 10⁻⁶ · U + 40 µV"},{"name":"","range":"10 V to 100 V","cmc":"40 · 10⁻⁶ · U + 0,6 mV"},{"name":"","range":"100 V to 1000 V","cmc":"47 · 10⁻⁶ · U + 7 mV"}],"regulatory_area_cs":"Napětí DC","search_cs":"Digitální měřiče napětí Multimetry Kalibrátory Napájecí zdroje Kalibrace — Napětí DC Přímá metoda; Mimo stálou lokalitu (P) Napětí DC Přímá metoda Mimo stálou lokalitu (P) EURAMET cg-15 v.3.0","technique_cs":"Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Digitální měřiče napětí\nMultimetry\nKalibrátory\nNapájecí zdroje"},{"_id":"c09ff621b35a4e550e137996","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki prądu analogowe","test_object_en":"Analogue ammeters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0 µA do 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA do 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA do 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA do 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A do 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A do 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A do 11 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"}],"parameters_en":[{"name":"","range":"0 µA to 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA to 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA to 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A to 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A to 11 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0 µA do 100 µA CMC 13 · 10⁻⁶ · I + 40 pA\n100 µA do 1 mA CMC 13 · 10⁻⁶ · I + 0,2 nA\n1 mA do 10 mA CMC 12 · 10⁻⁶ · I + 30 nA\n10 mA do 100 mA CMC 13 · 10⁻⁶ · I + 0,01 µA\n0,1 A do 1 A CMC 13 · 10⁻⁶ · I + 0,1 µA\n1 A do 3 A CMC 11 · 10⁻⁶ · I + 32 µA\n3 A do 11 A CMC 7 · 10⁻⁶ · I + 0,35 mA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"E /I 1/ MAP","norm_bases":["E /I 1/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Mierniki prądu analogowe Wzorcowanie — Prąd DC\nZakres:\n0 µA do 100 µA CMC 13 · 10⁻⁶ · I + 40 pA\n100 µA do 1 mA CMC 13 · 10⁻⁶ · I + 0,2 nA\n1 mA do 10 mA CMC 12 · 10⁻⁶ · I + 30 nA\n10 mA do 100 mA CMC 13 · 10⁻⁶ · I + 0,01 µA\n0,1 A do 1 A CMC 13 · 10⁻⁶ · I + 0,1 µA\n1 A do 3 A CMC 11 · 10⁻⁶ · I + 32 µA\n3 A do 11 A CMC 7 · 10⁻⁶ · I + 0,35 mA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) E /I 1/ MAP Mierniki pradu analogowe Wzorcowanie — Prad DC\nZakres:\n0 µA do 100 µA CMC 13 · 10⁻⁶ · I + 40 pA\n100 µA do 1 mA CMC 13 · 10⁻⁶ · I + 0,2 nA\n1 mA do 10 mA CMC 12 · 10⁻⁶ · I + 30 nA\n10 mA do 100 mA CMC 13 · 10⁻⁶ · I + 0,01 µA\n0,1 A do 1 A CMC 13 · 10⁻⁶ · I + 0,1 µA\n1 A do 3 A CMC 11 · 10⁻⁶ · I + 32 µA\n3 A do 11 A CMC 7 · 10⁻⁶ · I + 0,35 mA\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) E /I 1/ MAP","search_en":"Analogue ammeters Calibration — DC current Internal procedure; Direct method; At permanent location (S) DC current Internal procedure Direct method At permanent location (S) E /I 1/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0 µA to 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA to 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA bis 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A to 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A to 11 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"}],"regulatory_area_de":"DC-Strom","search_de":"Analoge Strommessgeräte Kalibrierung — DC-Strom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) E /I 1/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Strommessgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0 µA to 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA to 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA to 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A to 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A to 11 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"}],"regulatory_area_zh":"直流电流","search_zh":"模拟电流表 校准 — 直流电流 内部程序；直接法；在固定地点 (S) 直流电流 内部程序 直接法 在固定地点 (S) E /I 1/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"模拟电流表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0 µA to 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA to 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA to 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A to 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A to 11 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"}],"regulatory_area_cs":"Proud DC","search_cs":"Analogové měřiče proudu Kalibrace — Proud DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) E /I 1/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče proudu"},{"_id":"af25f0c2af751e4a04b6a04b","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki prądu cyfrowe\nMultimetry","test_object_en":"Digital ammeters\nMultimeters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0 µA do 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA do 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA do 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA do 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A do 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A do 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A do 11 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"}],"parameters_en":[{"name":"","range":"0 µA to 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA to 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA to 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A to 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A to 11 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","technique_en":"Direct and indirect method; At permanent location (S)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Direct and indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0 µA do 100 µA CMC 13 · 10⁻⁶ · I + 40 pA\n100 µA do 1 mA CMC 13 · 10⁻⁶ · I + 0,2 nA\n1 mA do 10 mA CMC 12 · 10⁻⁶ · I + 30 nA\n10 mA do 100 mA CMC 13 · 10⁻⁶ · I + 0,01 µA\n0,1 A do 1 A CMC 13 · 10⁻⁶ · I + 0,1 µA\n1 A do 3 A CMC 11 · 10⁻⁶ · I + 32 µA\n3 A do 11 A CMC 7 · 10⁻⁶ · I + 0,35 mA\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Mierniki prądu cyfrowe\nMultimetry Wzorcowanie — Prąd DC\nZakres:\n0 µA do 100 µA CMC 13 · 10⁻⁶ · I + 40 pA\n100 µA do 1 mA CMC 13 · 10⁻⁶ · I + 0,2 nA\n1 mA do 10 mA CMC 12 · 10⁻⁶ · I + 30 nA\n10 mA do 100 mA CMC 13 · 10⁻⁶ · I + 0,01 µA\n0,1 A do 1 A CMC 13 · 10⁻⁶ · I + 0,1 µA\n1 A do 3 A CMC 11 · 10⁻⁶ · I + 32 µA\n3 A do 11 A CMC 7 · 10⁻⁶ · I + 0,35 mA\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) EURAMET cg-15 v.3.0 Mierniki pradu cyfrowe\nMultimetry Wzorcowanie — Prad DC\nZakres:\n0 µA do 100 µA CMC 13 · 10⁻⁶ · I + 40 pA\n100 µA do 1 mA CMC 13 · 10⁻⁶ · I + 0,2 nA\n1 mA do 10 mA CMC 12 · 10⁻⁶ · I + 30 nA\n10 mA do 100 mA CMC 13 · 10⁻⁶ · I + 0,01 µA\n0,1 A do 1 A CMC 13 · 10⁻⁶ · I + 0,1 µA\n1 A do 3 A CMC 11 · 10⁻⁶ · I + 32 µA\n3 A do 11 A CMC 7 · 10⁻⁶ · I + 0,35 mA\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) EURAMET cg-15 v.3.0","search_en":"Digital ammeters Multimeters Calibration — DC current Direct and indirect method; At permanent location (S) DC current Direct and indirect method At permanent location (S) EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0 µA to 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA to 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA bis 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A to 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A to 11 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"}],"regulatory_area_de":"DC-Strom","search_de":"Digitale Strommessgeräte Multimeter Kalibrierung — DC-Strom Direktes und indirektes Verfahren; Am festen Standort (S) DC-Strom Direktes und indirektes Verfahren Am festen Standort (S) EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Strommessgeräte\nMultimeter","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0 µA to 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA to 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA to 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A to 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A to 11 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"}],"regulatory_area_zh":"直流电流","search_zh":"数字电流表 万用表 校准 — 直流电流 直接法和间接法; 在固定地点 (S) 直流电流 直接法和间接法 在固定地点 (S) EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法; 在固定地点 (S)","techniques_zh":["直接法和间接法","在固定地点 (S)"],"test_object_zh":"数字电流表\n万用表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0 µA to 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA to 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA to 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A to 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A to 11 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"}],"regulatory_area_cs":"Proud DC","search_cs":"Digitální měřiče proudu Multimetry Kalibrace — Proud DC Přímá a nepřímá metoda; Ve stálé lokalitě (S) Proud DC Přímá a nepřímá metoda Ve stálé lokalitě (S) EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Přímá a nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální měřiče proudu\nMultimetry"},{"_id":"884fb1e6ae4cc167949bde37","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"10 A do 16,5 A","cmc":"2 · 10⁻³ · I + 2 mA"},{"name":"","range":"16,5 A do 149,999 A","cmc":"2 · 10⁻³ · I + 12 mA"},{"name":"","range":"150 A do 550 A","cmc":"2 · 10⁻³ · I + 40 mA"}],"parameters_en":[{"name":"","range":"10 A to 16,5 A","cmc":"2 · 10⁻³ · I + 2 mA"},{"name":"","range":"16,5 A to 149,999 A","cmc":"2 · 10⁻³ · I + 12 mA"},{"name":"","range":"150 A to 550 A","cmc":"2 · 10⁻³ · I + 40 mA"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n10 A do 16,5 A CMC 2 · 10⁻³ · I + 2 mA\n16,5 A do 149,999 A CMC 2 · 10⁻³ · I + 12 mA\n150 A do 550 A CMC 2 · 10⁻³ · I + 40 mA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"E /I 2/ MAP","norm_bases":["E /I 2/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Mierniki cęgowe Wzorcowanie — Prąd DC\nZakres:\n10 A do 16,5 A CMC 2 · 10⁻³ · I + 2 mA\n16,5 A do 149,999 A CMC 2 · 10⁻³ · I + 12 mA\n150 A do 550 A CMC 2 · 10⁻³ · I + 40 mA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) E /I 2/ MAP Mierniki cegowe Wzorcowanie — Prad DC\nZakres:\n10 A do 16,5 A CMC 2 · 10⁻³ · I + 2 mA\n16,5 A do 149,999 A CMC 2 · 10⁻³ · I + 12 mA\n150 A do 550 A CMC 2 · 10⁻³ · I + 40 mA\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) E /I 2/ MAP","search_en":"Clamp meters Calibration — DC current Internal procedure; Direct method; At permanent location (S) DC current Internal procedure Direct method At permanent location (S) E /I 2/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"10 A to 16,5 A","cmc":"2 · 10⁻³ · I + 2 mA"},{"name":"","range":"16,5 A to 149,999 A","cmc":"2 · 10⁻³ · I + 12 mA"},{"name":"","range":"150 A to 550 A","cmc":"2 · 10⁻³ · I + 40 mA"}],"regulatory_area_de":"DC-Strom","search_de":"Zangenmessgeräte Kalibrierung — DC-Strom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) E /I 2/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"10 A to 16,5 A","cmc":"2 · 10⁻³ · I + 2 mA"},{"name":"","range":"16,5 A to 149,999 A","cmc":"2 · 10⁻³ · I + 12 mA"},{"name":"","range":"150 A to 550 A","cmc":"2 · 10⁻³ · I + 40 mA"}],"regulatory_area_zh":"直流电流","search_zh":"钳形表 校准 — 直流电流 内部程序；直接法；在固定地点 (S) 直流电流 内部程序 直接法 在固定地点 (S) E /I 2/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"10 A to 16,5 A","cmc":"2 · 10⁻³ · I + 2 mA"},{"name":"","range":"16,5 A to 149,999 A","cmc":"2 · 10⁻³ · I + 12 mA"},{"name":"","range":"150 A to 550 A","cmc":"2 · 10⁻³ · I + 40 mA"}],"regulatory_area_cs":"Proud DC","search_cs":"Klešťové měřiče Kalibrace — Proud DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) E /I 2/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Klešťové měřiče"},{"_id":"81d05ec5401de681f33691c6","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Kalibratory\nZasilacze","test_object_en":"Calibrators\nPower supplies","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0 µA do 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA do 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA do 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA do 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A do 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A do 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A do 10 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"},{"name":"","range":"10 A do 30 A","cmc":"10 · 10⁻⁶ · I + 3,4 mA"},{"name":"","range":"30 A do 100 A","cmc":"120 · 10⁻⁶ · I + 0,1 mA"}],"parameters_en":[{"name":"","range":"0 µA to 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA to 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA to 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A to 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A to 10 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"},{"name":"","range":"10 A to 30 A","cmc":"10 · 10⁻⁶ · I + 3,4 mA"},{"name":"","range":"30 A to 100 A","cmc":"120 · 10⁻⁶ · I + 0,1 mA"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","technique_en":"Direct and indirect method; At permanent location (S)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Direct and indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0 µA do 100 µA CMC 13 · 10⁻⁶ · I + 40 pA\n100 µA do 1 mA CMC 13 · 10⁻⁶ · I + 0,2 nA\n1 mA do 10 mA CMC 12 · 10⁻⁶ · I + 30 nA\n10 mA do 100 mA CMC 13 · 10⁻⁶ · I + 0,01 µA\n0,1 A do 1 A CMC 13 · 10⁻⁶ · I + 0,1 µA\n1 A do 3 A CMC 11 · 10⁻⁶ · I + 32 µA\n3 A do 10 A CMC 7 · 10⁻⁶ · I + 0,35 mA\n10 A do 30 A CMC 10 · 10⁻⁶ · I + 3,4 mA\n30 A do 100 A CMC 120 · 10⁻⁶ · I + 0,1 mA\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Kalibratory\nZasilacze Wzorcowanie — Prąd DC\nZakres:\n0 µA do 100 µA CMC 13 · 10⁻⁶ · I + 40 pA\n100 µA do 1 mA CMC 13 · 10⁻⁶ · I + 0,2 nA\n1 mA do 10 mA CMC 12 · 10⁻⁶ · I + 30 nA\n10 mA do 100 mA CMC 13 · 10⁻⁶ · I + 0,01 µA\n0,1 A do 1 A CMC 13 · 10⁻⁶ · I + 0,1 µA\n1 A do 3 A CMC 11 · 10⁻⁶ · I + 32 µA\n3 A do 10 A CMC 7 · 10⁻⁶ · I + 0,35 mA\n10 A do 30 A CMC 10 · 10⁻⁶ · I + 3,4 mA\n30 A do 100 A CMC 120 · 10⁻⁶ · I + 0,1 mA\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) EURAMET cg-15 v.3.0 Kalibratory\nZasilacze Wzorcowanie — Prad DC\nZakres:\n0 µA do 100 µA CMC 13 · 10⁻⁶ · I + 40 pA\n100 µA do 1 mA CMC 13 · 10⁻⁶ · I + 0,2 nA\n1 mA do 10 mA CMC 12 · 10⁻⁶ · I + 30 nA\n10 mA do 100 mA CMC 13 · 10⁻⁶ · I + 0,01 µA\n0,1 A do 1 A CMC 13 · 10⁻⁶ · I + 0,1 µA\n1 A do 3 A CMC 11 · 10⁻⁶ · I + 32 µA\n3 A do 10 A CMC 7 · 10⁻⁶ · I + 0,35 mA\n10 A do 30 A CMC 10 · 10⁻⁶ · I + 3,4 mA\n30 A do 100 A CMC 120 · 10⁻⁶ · I + 0,1 mA\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) EURAMET cg-15 v.3.0","search_en":"Calibrators Power supplies Calibration — DC current Direct and indirect method; At permanent location (S) DC current Direct and indirect method At permanent location (S) EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0 µA to 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA to 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA bis 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A to 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A to 10 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"},{"name":"","range":"10 A bis 30 A","cmc":"10 · 10⁻⁶ · I + 3,4 mA"},{"name":"","range":"30 A to 100 A","cmc":"120 · 10⁻⁶ · I + 0,1 mA"}],"regulatory_area_de":"DC-Strom","search_de":"Kalibratoren Netzgeräte Kalibrierung — DC-Strom Direktes und indirektes Verfahren; Am festen Standort (S) DC-Strom Direktes und indirektes Verfahren Am festen Standort (S) EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0 µA to 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA to 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA to 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A to 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A to 10 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"},{"name":"","range":"10 A to 30 A","cmc":"10 · 10⁻⁶ · I + 3,4 mA"},{"name":"","range":"30 A to 100 A","cmc":"120 · 10⁻⁶ · I + 0,1 mA"}],"regulatory_area_zh":"直流电流","search_zh":"校准器 电源 校准 — 直流电流 直接法和间接法; 在固定地点 (S) 直流电流 直接法和间接法 在固定地点 (S) EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法; 在固定地点 (S)","techniques_zh":["直接法和间接法","在固定地点 (S)"],"test_object_zh":"校准器\n电源","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0 µA to 100 µA","cmc":"13 · 10⁻⁶ · I + 40 pA"},{"name":"","range":"100 µA to 1 mA","cmc":"13 · 10⁻⁶ · I + 0,2 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"12 · 10⁻⁶ · I + 30 nA"},{"name":"","range":"10 mA to 100 mA","cmc":"13 · 10⁻⁶ · I + 0,01 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"13 · 10⁻⁶ · I + 0,1 µA"},{"name":"","range":"1 A to 3 A","cmc":"11 · 10⁻⁶ · I + 32 µA"},{"name":"","range":"3 A to 10 A","cmc":"7 · 10⁻⁶ · I + 0,35 mA"},{"name":"","range":"10 A to 30 A","cmc":"10 · 10⁻⁶ · I + 3,4 mA"},{"name":"","range":"30 A to 100 A","cmc":"120 · 10⁻⁶ · I + 0,1 mA"}],"regulatory_area_cs":"Proud DC","search_cs":"Kalibrátory Napájecí zdroje Kalibrace — Proud DC Přímá a nepřímá metoda; Ve stálé lokalitě (S) Proud DC Přímá a nepřímá metoda Ve stálé lokalitě (S) EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Přímá a nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nNapájecí zdroje"},{"_id":"81cb7dc7c31dd4cba1e600b9","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki prądu analogowe","test_object_en":"Analogue ammeters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,1 mA do 1 mA","cmc":"31 · 10⁻⁶ · I + 2,3 nA"},{"name":"","range":"1 mA do 10 mA","cmc":"43 · 10⁻⁶ · I + 0,11 µA"},{"name":"","range":"10 mA do 100 mA","cmc":"31 · 10⁻⁶ · I + 0,22 µA"},{"name":"","range":"0,1 A do 1 A","cmc":"31 · 10⁻⁶ · I + 2,2 µA"},{"name":"","range":"1 A do 3 A","cmc":"40 · 10⁻⁶ · I + 0,11 mA"},{"name":"","range":"3 A do 10 A","cmc":"43 · 10⁻⁶ · I + 1,1 mA"},{"name":"","range":"10 A do 30 A","cmc":"50 · 10⁻⁶ · I + 11 mA"},{"name":"","range":"30 A do 100 A","cmc":"100 · 10⁻⁶ · I + 9 mA"}],"parameters_en":[{"name":"","range":"0,1 mA to 1 mA","cmc":"31 · 10⁻⁶ · I + 2,3 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"43 · 10⁻⁶ · I + 0,11 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"31 · 10⁻⁶ · I + 0,22 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"31 · 10⁻⁶ · I + 2,2 µA"},{"name":"","range":"1 A to 3 A","cmc":"40 · 10⁻⁶ · I + 0,11 mA"},{"name":"","range":"3 A to 10 A","cmc":"43 · 10⁻⁶ · I + 1,1 mA"},{"name":"","range":"10 A to 30 A","cmc":"50 · 10⁻⁶ · I + 11 mA"},{"name":"","range":"30 A to 100 A","cmc":"100 · 10⁻⁶ · I + 9 mA"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,1 mA do 1 mA CMC 31 · 10⁻⁶ · I + 2,3 nA\n1 mA do 10 mA CMC 43 · 10⁻⁶ · I + 0,11 µA\n10 mA do 100 mA CMC 31 · 10⁻⁶ · I + 0,22 µA\n0,1 A do 1 A CMC 31 · 10⁻⁶ · I + 2,2 µA\n1 A do 3 A CMC 40 · 10⁻⁶ · I + 0,11 mA\n3 A do 10 A CMC 43 · 10⁻⁶ · I + 1,1 mA\n10 A do 30 A CMC 50 · 10⁻⁶ · I + 11 mA\n30 A do 100 A CMC 100 · 10⁻⁶ · I + 9 mA\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"E /I 1/ MAP\nP4 / MAP","norm_bases":["E /I 1/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":true,"location_of_activity":"P","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Mierniki prądu analogowe Wzorcowanie — Prąd DC\nZakres:\n0,1 mA do 1 mA CMC 31 · 10⁻⁶ · I + 2,3 nA\n1 mA do 10 mA CMC 43 · 10⁻⁶ · I + 0,11 µA\n10 mA do 100 mA CMC 31 · 10⁻⁶ · I + 0,22 µA\n0,1 A do 1 A CMC 31 · 10⁻⁶ · I + 2,2 µA\n1 A do 3 A CMC 40 · 10⁻⁶ · I + 0,11 mA\n3 A do 10 A CMC 43 · 10⁻⁶ · I + 1,1 mA\n10 A do 30 A CMC 50 · 10⁻⁶ · I + 11 mA\n30 A do 100 A CMC 100 · 10⁻⁶ · I + 9 mA\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) E /I 1/ MAP\nP4 / MAP Mierniki pradu analogowe Wzorcowanie — Prad DC\nZakres:\n0,1 mA do 1 mA CMC 31 · 10⁻⁶ · I + 2,3 nA\n1 mA do 10 mA CMC 43 · 10⁻⁶ · I + 0,11 µA\n10 mA do 100 mA CMC 31 · 10⁻⁶ · I + 0,22 µA\n0,1 A do 1 A CMC 31 · 10⁻⁶ · I + 2,2 µA\n1 A do 3 A CMC 40 · 10⁻⁶ · I + 0,11 mA\n3 A do 10 A CMC 43 · 10⁻⁶ · I + 1,1 mA\n10 A do 30 A CMC 50 · 10⁻⁶ · I + 11 mA\n30 A do 100 A CMC 100 · 10⁻⁶ · I + 9 mA\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) E /I 1/ MAP\nP4 / MAP","search_en":"Analogue ammeters Calibration — DC current Internal procedure; Direct method; Outside of permanent location (P) DC current Internal procedure Direct method Outside of permanent location (P) E /I 1/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,1 mA to 1 mA","cmc":"31 · 10⁻⁶ · I + 2,3 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"43 · 10⁻⁶ · I + 0,11 µA"},{"name":"","range":"10 mA bis 100 mA","cmc":"31 · 10⁻⁶ · I + 0,22 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"31 · 10⁻⁶ · I + 2,2 µA"},{"name":"","range":"1 A to 3 A","cmc":"40 · 10⁻⁶ · I + 0,11 mA"},{"name":"","range":"3 A to 10 A","cmc":"43 · 10⁻⁶ · I + 1,1 mA"},{"name":"","range":"10 A bis 30 A","cmc":"50 · 10⁻⁶ · I + 11 mA"},{"name":"","range":"30 A to 100 A","cmc":"100 · 10⁻⁶ · I + 9 mA"}],"regulatory_area_de":"DC-Strom","search_de":"Analoge Strommessgeräte Kalibrierung — DC-Strom Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) DC-Strom Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) E /I 1/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Analoge Strommessgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,1 mA to 1 mA","cmc":"31 · 10⁻⁶ · I + 2,3 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"43 · 10⁻⁶ · I + 0,11 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"31 · 10⁻⁶ · I + 0,22 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"31 · 10⁻⁶ · I + 2,2 µA"},{"name":"","range":"1 A to 3 A","cmc":"40 · 10⁻⁶ · I + 0,11 mA"},{"name":"","range":"3 A to 10 A","cmc":"43 · 10⁻⁶ · I + 1,1 mA"},{"name":"","range":"10 A to 30 A","cmc":"50 · 10⁻⁶ · I + 11 mA"},{"name":"","range":"30 A to 100 A","cmc":"100 · 10⁻⁶ · I + 9 mA"}],"regulatory_area_zh":"直流电流","search_zh":"模拟电流表 校准 — 直流电流 内部程序；直接法；固定地点以外 (P) 直流电流 内部程序 直接法 固定地点以外 (P) E /I 1/ MAP P4 / MAP","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"模拟电流表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,1 mA to 1 mA","cmc":"31 · 10⁻⁶ · I + 2,3 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"43 · 10⁻⁶ · I + 0,11 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"31 · 10⁻⁶ · I + 0,22 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"31 · 10⁻⁶ · I + 2,2 µA"},{"name":"","range":"1 A to 3 A","cmc":"40 · 10⁻⁶ · I + 0,11 mA"},{"name":"","range":"3 A to 10 A","cmc":"43 · 10⁻⁶ · I + 1,1 mA"},{"name":"","range":"10 A to 30 A","cmc":"50 · 10⁻⁶ · I + 11 mA"},{"name":"","range":"30 A to 100 A","cmc":"100 · 10⁻⁶ · I + 9 mA"}],"regulatory_area_cs":"Proud DC","search_cs":"Analogové měřiče proudu Kalibrace — Proud DC Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Proud DC Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) E /I 1/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Analogové měřiče proudu"},{"_id":"4f97fe724203f81fa666e1ea","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki prądu cyfrowe\nMultimetry\nKalibratory\nZasilacze","test_object_en":"Digital ammeters\nMultimeters\nCalibrators\nPower supplies","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,1 mA do 1 mA","cmc":"31 · 10⁻⁶ · I + 2,3 nA"},{"name":"","range":"1 mA do 10 mA","cmc":"43 · 10⁻⁶ · I + 0,11 µA"},{"name":"","range":"10 mA do 100 mA","cmc":"31 · 10⁻⁶ · I + 0,22 µA"},{"name":"","range":"0,1 A do 1 A","cmc":"31 · 10⁻⁶ · I + 2,2 µA"},{"name":"","range":"1 A do 3 A","cmc":"40 · 10⁻⁶ · I + 0,11 mA"},{"name":"","range":"3 A do 10 A","cmc":"43 · 10⁻⁶ · I + 1,1 mA"},{"name":"","range":"10 A do 30 A","cmc":"50 · 10⁻⁶ · I + 11 mA"},{"name":"","range":"30 A do 100 A","cmc":"100 · 10⁻⁶ · I + 9 mA"}],"parameters_en":[{"name":"","range":"0,1 mA to 1 mA","cmc":"31 · 10⁻⁶ · I + 2,3 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"43 · 10⁻⁶ · I + 0,11 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"31 · 10⁻⁶ · I + 0,22 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"31 · 10⁻⁶ · I + 2,2 µA"},{"name":"","range":"1 A to 3 A","cmc":"40 · 10⁻⁶ · I + 0,11 mA"},{"name":"","range":"3 A to 10 A","cmc":"43 · 10⁻⁶ · I + 1,1 mA"},{"name":"","range":"10 A to 30 A","cmc":"50 · 10⁻⁶ · I + 11 mA"},{"name":"","range":"30 A to 100 A","cmc":"100 · 10⁻⁶ · I + 9 mA"}],"technique":"Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Direct method; Outside of permanent location (P)","techniques":["Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,1 mA do 1 mA CMC 31 · 10⁻⁶ · I + 2,3 nA\n1 mA do 10 mA CMC 43 · 10⁻⁶ · I + 0,11 µA\n10 mA do 100 mA CMC 31 · 10⁻⁶ · I + 0,22 µA\n0,1 A do 1 A CMC 31 · 10⁻⁶ · I + 2,2 µA\n1 A do 3 A CMC 40 · 10⁻⁶ · I + 0,11 mA\n3 A do 10 A CMC 43 · 10⁻⁶ · I + 1,1 mA\n10 A do 30 A CMC 50 · 10⁻⁶ · I + 11 mA\n30 A do 100 A CMC 100 · 10⁻⁶ · I + 9 mA\nMetoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":true,"location_of_activity":"P","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Mierniki prądu cyfrowe\nMultimetry\nKalibratory\nZasilacze Wzorcowanie — Prąd DC\nZakres:\n0,1 mA do 1 mA CMC 31 · 10⁻⁶ · I + 2,3 nA\n1 mA do 10 mA CMC 43 · 10⁻⁶ · I + 0,11 µA\n10 mA do 100 mA CMC 31 · 10⁻⁶ · I + 0,22 µA\n0,1 A do 1 A CMC 31 · 10⁻⁶ · I + 2,2 µA\n1 A do 3 A CMC 40 · 10⁻⁶ · I + 0,11 mA\n3 A do 10 A CMC 43 · 10⁻⁶ · I + 1,1 mA\n10 A do 30 A CMC 50 · 10⁻⁶ · I + 11 mA\n30 A do 100 A CMC 100 · 10⁻⁶ · I + 9 mA\nMetoda bezpośrednia; Poza stałą lokalizacją (P) EURAMET cg-15 v.3.0 Mierniki pradu cyfrowe\nMultimetry\nKalibratory\nZasilacze Wzorcowanie — Prad DC\nZakres:\n0,1 mA do 1 mA CMC 31 · 10⁻⁶ · I + 2,3 nA\n1 mA do 10 mA CMC 43 · 10⁻⁶ · I + 0,11 µA\n10 mA do 100 mA CMC 31 · 10⁻⁶ · I + 0,22 µA\n0,1 A do 1 A CMC 31 · 10⁻⁶ · I + 2,2 µA\n1 A do 3 A CMC 40 · 10⁻⁶ · I + 0,11 mA\n3 A do 10 A CMC 43 · 10⁻⁶ · I + 1,1 mA\n10 A do 30 A CMC 50 · 10⁻⁶ · I + 11 mA\n30 A do 100 A CMC 100 · 10⁻⁶ · I + 9 mA\nMetoda bezposrednia; Poza stala lokalizacja (P) EURAMET cg-15 v.3.0","search_en":"Digital ammeters Multimeters Calibrators Power supplies Calibration — DC current Direct method; Outside of permanent location (P) DC current Direct method Outside of permanent location (P) EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,1 mA to 1 mA","cmc":"31 · 10⁻⁶ · I + 2,3 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"43 · 10⁻⁶ · I + 0,11 µA"},{"name":"","range":"10 mA bis 100 mA","cmc":"31 · 10⁻⁶ · I + 0,22 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"31 · 10⁻⁶ · I + 2,2 µA"},{"name":"","range":"1 A to 3 A","cmc":"40 · 10⁻⁶ · I + 0,11 mA"},{"name":"","range":"3 A to 10 A","cmc":"43 · 10⁻⁶ · I + 1,1 mA"},{"name":"","range":"10 A bis 30 A","cmc":"50 · 10⁻⁶ · I + 11 mA"},{"name":"","range":"30 A to 100 A","cmc":"100 · 10⁻⁶ · I + 9 mA"}],"regulatory_area_de":"DC-Strom","search_de":"Digitale Strommessgeräte Multimeter Kalibratoren Netzgeräte Kalibrierung — DC-Strom Direktes Verfahren; Außerhalb des festen Standorts (P) DC-Strom Direktes Verfahren Außerhalb des festen Standorts (P) EURAMET cg-15 v.3.0","technique_de":"Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Digitale Strommessgeräte\nMultimeter\nKalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,1 mA to 1 mA","cmc":"31 · 10⁻⁶ · I + 2,3 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"43 · 10⁻⁶ · I + 0,11 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"31 · 10⁻⁶ · I + 0,22 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"31 · 10⁻⁶ · I + 2,2 µA"},{"name":"","range":"1 A to 3 A","cmc":"40 · 10⁻⁶ · I + 0,11 mA"},{"name":"","range":"3 A to 10 A","cmc":"43 · 10⁻⁶ · I + 1,1 mA"},{"name":"","range":"10 A to 30 A","cmc":"50 · 10⁻⁶ · I + 11 mA"},{"name":"","range":"30 A to 100 A","cmc":"100 · 10⁻⁶ · I + 9 mA"}],"regulatory_area_zh":"直流电流","search_zh":"数字电流表 万用表 校准器 电源 校准 — 直流电流 直接法；固定地点以外 (P) 直流电流 直接法 固定地点以外 (P) EURAMET cg-15 v.3.0","technique_zh":"直接法；固定地点以外 (P)","techniques_zh":["直接法","固定地点以外 (P)"],"test_object_zh":"数字电流表\n万用表\n校准器\n电源","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,1 mA to 1 mA","cmc":"31 · 10⁻⁶ · I + 2,3 nA"},{"name":"","range":"1 mA to 10 mA","cmc":"43 · 10⁻⁶ · I + 0,11 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"31 · 10⁻⁶ · I + 0,22 µA"},{"name":"","range":"0,1 A to 1 A","cmc":"31 · 10⁻⁶ · I + 2,2 µA"},{"name":"","range":"1 A to 3 A","cmc":"40 · 10⁻⁶ · I + 0,11 mA"},{"name":"","range":"3 A to 10 A","cmc":"43 · 10⁻⁶ · I + 1,1 mA"},{"name":"","range":"10 A to 30 A","cmc":"50 · 10⁻⁶ · I + 11 mA"},{"name":"","range":"30 A to 100 A","cmc":"100 · 10⁻⁶ · I + 9 mA"}],"regulatory_area_cs":"Proud DC","search_cs":"Digitální měřiče proudu Multimetry Kalibrátory Napájecí zdroje Kalibrace — Proud DC Přímá metoda; Mimo stálou lokalitu (P) Proud DC Přímá metoda Mimo stálou lokalitu (P) EURAMET cg-15 v.3.0","technique_cs":"Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Digitální měřiče proudu\nMultimetry\nKalibrátory\nNapájecí zdroje"},{"_id":"94bb64408c705ff01a94be39","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki napięcia analogowe","test_object_en":"Analogue voltmeters","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"f = 10 Hz do 40 Hz","range":"0,2 mV do 10 mV","cmc":"34 · 10⁻⁵ · U + 3,5 µV"},{"name":"f = 10 Hz do 40 Hz","range":"0,01 V do 0,1 V","cmc":"8 · 10⁻⁵ · U + 4,5 µV"},{"name":"f = 10 Hz do 40 Hz","range":"0,1 V do 1 V","cmc":"8 · 10⁻⁵ · U + 45 µV"},{"name":"f = 10 Hz do 40 Hz","range":"1 V do 10 V","cmc":"8 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 10 Hz do 40 Hz","range":"10 V do 100 V","cmc":"23 · 10⁻⁵ · U + 4,7 mV"},{"name":"f = 10 Hz do 40 Hz","range":"100 V do 1000 V","cmc":"46 · 10⁻⁵ · U + 46 mV"},{"name":"f = 40 Hz do 1 kHz","range":"0,2 mV do 10 mV","cmc":"23 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 40 Hz do 1 kHz","range":"0,01 V do 0,1 V","cmc":"8 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 40 Hz do 1 kHz","range":"0,1 V do 1 V","cmc":"8 · 10⁻⁵ · U + 23 µV"},{"name":"f = 40 Hz do 1 kHz","range":"1 V do 10 V","cmc":"8 · 10⁻⁵ · U + 0,2 mV"},{"name":"f = 40 Hz do 1 kHz","range":"10 V do 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 40 Hz do 1 kHz","range":"100 V do 1000 V","cmc":"46 · 10⁻⁵ · U + 23 mV"},{"name":"f = 1 kHz do 20 kHz","range":"0,2 mV do 10 mV","cmc":"34 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 1 kHz do 20 kHz","range":"0,01 V do 0,1 V","cmc":"16 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 1 kHz do 20 kHz","range":"0,1 V do 1 V","cmc":"16 · 10⁻⁵ · U + 23 µV"},{"name":"f = 1 kHz do 20 kHz","range":"1 V do 10 V","cmc":"16 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 1 kHz do 20 kHz","range":"10 V do 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 1 kHz do 20 kHz","range":"100 V do 1000 V","cmc":"69 · 10⁻⁵ · U + 23 mV"},{"name":"f = 50 kHz do 100 kHz","range":"0,2 mV do 10 mV","cmc":"58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV"},{"name":"f = 50 kHz do 100 kHz","range":"0,01 V do 0,1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV"},{"name":"f = 50 kHz do 100 kHz","range":"0,1 V do 1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 28 µV"},{"name":"f = 50 kHz do 100 kHz","range":"1 V do 10 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV"},{"name":"f = 50 kHz do 100 kHz","range":"10 V do 33 V","cmc":"15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV"},{"name":"f = 100 kHz do 300 kHz","range":"0,2 mV do 10 mV","cmc":"460 · 10⁻⁴ · U + 2,2 µV"},{"name":"f = 100 kHz do 300 kHz","range":"0,01 V do 0,1 V","cmc":"35 · 10⁻⁴ · U + 15 µV"},{"name":"f = 100 kHz do 300 kHz","range":"0,1 V do 1 V","cmc":"35 · 10⁻⁴ · U + 0,1 mV"},{"name":"f = 100 kHz do 300 kHz","range":"1 V do 10 V","cmc":"35 · 10⁻⁴ · U + 1,1 mV"},{"name":"f = 100 kHz do 300 kHz","range":"10 V do 33 V","cmc":"44 · 10⁻⁴ · U + 14 mV"}],"parameters_en":[{"name":"f = 10 Hz to 40 Hz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 3,5 µV"},{"name":"f = 10 Hz to 40 Hz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 4,5 µV"},{"name":"f = 10 Hz to 40 Hz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 45 µV"},{"name":"f = 10 Hz to 40 Hz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 10 Hz to 40 Hz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 4,7 mV"},{"name":"f = 10 Hz to 40 Hz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 46 mV"},{"name":"f = 40 Hz to 1 kHz","range":"0,2 mV to 10 mV","cmc":"23 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 40 Hz to 1 kHz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 40 Hz to 1 kHz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 23 µV"},{"name":"f = 40 Hz to 1 kHz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,2 mV"},{"name":"f = 40 Hz to 1 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 40 Hz to 1 kHz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 23 mV"},{"name":"f = 1 kHz to 20 kHz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 1 kHz to 20 kHz","range":"0,01 V to 0,1 V","cmc":"16 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 1 kHz to 20 kHz","range":"0,1 V to 1 V","cmc":"16 · 10⁻⁵ · U + 23 µV"},{"name":"f = 1 kHz to 20 kHz","range":"1 V to 10 V","cmc":"16 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 1 kHz to 20 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 1 kHz to 20 kHz","range":"100 V to 1000 V","cmc":"69 · 10⁻⁵ · U + 23 mV"},{"name":"f = 50 kHz to 100 kHz","range":"0,2 mV to 10 mV","cmc":"58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV"},{"name":"f = 50 kHz to 100 kHz","range":"0,01 V to 0,1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV"},{"name":"f = 50 kHz to 100 kHz","range":"0,1 V to 1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 28 µV"},{"name":"f = 50 kHz to 100 kHz","range":"1 V to 10 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV"},{"name":"f = 50 kHz to 100 kHz","range":"10 V to 33 V","cmc":"15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV"},{"name":"f = 100 kHz to 300 kHz","range":"0,2 mV to 10 mV","cmc":"460 · 10⁻⁴ · U + 2,2 µV"},{"name":"f = 100 kHz to 300 kHz","range":"0,01 V to 0,1 V","cmc":"35 · 10⁻⁴ · U + 15 µV"},{"name":"f = 100 kHz to 300 kHz","range":"0,1 V to 1 V","cmc":"35 · 10⁻⁴ · U + 0,1 mV"},{"name":"f = 100 kHz to 300 kHz","range":"1 V to 10 V","cmc":"35 · 10⁻⁴ · U + 1,1 mV"},{"name":"f = 100 kHz to 300 kHz","range":"10 V to 33 V","cmc":"44 · 10⁻⁴ · U + 14 mV"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\nf = 10 Hz do 40 Hz 0,2 mV do 10 mV CMC 34 · 10⁻⁵ · U + 3,5 µV\nf = 10 Hz do 40 Hz 0,01 V do 0,1 V CMC 8 · 10⁻⁵ · U + 4,5 µV\nf = 10 Hz do 40 Hz 0,1 V do 1 V CMC 8 · 10⁻⁵ · U + 45 µV\nf = 10 Hz do 40 Hz 1 V do 10 V CMC 8 · 10⁻⁵ · U + 0,4 mV\nf = 10 Hz do 40 Hz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 4,7 mV\nf = 10 Hz do 40 Hz 100 V do 1000 V CMC 46 · 10⁻⁵ · U + 46 mV\nf = 40 Hz do 1 kHz 0,2 mV do 10 mV CMC 23 · 10⁻⁵ · U + 1,3 µV\nf = 40 Hz do 1 kHz 0,01 V do 0,1 V CMC 8 · 10⁻⁵ · U + 2,3 µV\nf = 40 Hz do 1 kHz 0,1 V do 1 V CMC 8 · 10⁻⁵ · U + 23 µV\nf = 40 Hz do 1 kHz 1 V do 10 V CMC 8 · 10⁻⁵ · U + 0,2 mV\nf = 40 Hz do 1 kHz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 2,3 mV\nf = 40 Hz do 1 kHz 100 V do 1000 V CMC 46 · 10⁻⁵ · U + 23 mV\nf = 1 kHz do 20 kHz 0,2 mV do 10 mV CMC 34 · 10⁻⁵ · U + 1,3 µV\nf = 1 kHz do 20 kHz 0,01 V do 0,1 V CMC 16 · 10⁻⁵ · U + 2,3 µV\nf = 1 kHz do 20 kHz 0,1 V do 1 V CMC 16 · 10⁻⁵ · U + 23 µV\nf = 1 kHz do 20 kHz 1 V do 10 V CMC 16 · 10⁻⁵ · U + 0,4 mV\nf = 1 kHz do 20 kHz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 2,3 mV\nf = 1 kHz do 20 kHz 100 V do 1000 V CMC 69 · 10⁻⁵ · U + 23 mV\nf = 50 kHz do 100 kHz 0,2 mV do 10 mV CMC 58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV\nf = 50 kHz do 100 kHz 0,01 V do 0,1 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV\nf = 50 kHz do 100 kHz 0,1 V do 1 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 28 µV\nf = 50 kHz do 100 kHz 1 V do 10 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV\nf = 50 kHz do 100 kHz 10 V do 33 V CMC 15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV\nf = 100 kHz do 300 kHz 0,2 mV do 10 mV CMC 460 · 10⁻⁴ · U + 2,2 µV\nf = 100 kHz do 300 kHz 0,01 V do 0,1 V CMC 35 · 10⁻⁴ · U + 15 µV\nf = 100 kHz do 300 kHz 0,1 V do 1 V CMC 35 · 10⁻⁴ · U + 0,1 mV\nf = 100 kHz do 300 kHz 1 V do 10 V CMC 35 · 10⁻⁴ · U + 1,1 mV\nf = 100 kHz do 300 kHz 10 V do 33 V CMC 44 · 10⁻⁴ · U + 14 mV\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"E /I 1/ MAP","norm_bases":["E /I 1/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":"U – wielkość mierzona (V)","note_en":"U – measured value (V)","search_text":"Mierniki napięcia analogowe Wzorcowanie — Napięcie AC\nZakres:\nf = 10 Hz do 40 Hz 0,2 mV do 10 mV CMC 34 · 10⁻⁵ · U + 3,5 µV\nf = 10 Hz do 40 Hz 0,01 V do 0,1 V CMC 8 · 10⁻⁵ · U + 4,5 µV\nf = 10 Hz do 40 Hz 0,1 V do 1 V CMC 8 · 10⁻⁵ · U + 45 µV\nf = 10 Hz do 40 Hz 1 V do 10 V CMC 8 · 10⁻⁵ · U + 0,4 mV\nf = 10 Hz do 40 Hz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 4,7 mV\nf = 10 Hz do 40 Hz 100 V do 1000 V CMC 46 · 10⁻⁵ · U + 46 mV\nf = 40 Hz do 1 kHz 0,2 mV do 10 mV CMC 23 · 10⁻⁵ · U + 1,3 µV\nf = 40 Hz do 1 kHz 0,01 V do 0,1 V CMC 8 · 10⁻⁵ · U + 2,3 µV\nf = 40 Hz do 1 kHz 0,1 V do 1 V CMC 8 · 10⁻⁵ · U + 23 µV\nf = 40 Hz do 1 kHz 1 V do 10 V CMC 8 · 10⁻⁵ · U + 0,2 mV\nf = 40 Hz do 1 kHz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 2,3 mV\nf = 40 Hz do 1 kHz 100 V do 1000 V CMC 46 · 10⁻⁵ · U + 23 mV\nf = 1 kHz do 20 kHz 0,2 mV do 10 mV CMC 34 · 10⁻⁵ · U + 1,3 µV\nf = 1 kHz do 20 kHz 0,01 V do 0,1 V CMC 16 · 10⁻⁵ · U + 2,3 µV\nf = 1 kHz do 20 kHz 0,1 V do 1 V CMC 16 · 10⁻⁵ · U + 23 µV\nf = 1 kHz do 20 kHz 1 V do 10 V CMC 16 · 10⁻⁵ · U + 0,4 mV\nf = 1 kHz do 20 kHz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 2,3 mV\nf = 1 kHz do 20 kHz 100 V do 1000 V CMC 69 · 10⁻⁵ · U + 23 mV\nf = 50 kHz do 100 kHz 0,2 mV do 10 mV CMC 58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV\nf = 50 kHz do 100 kHz 0,01 V do 0,1 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV\nf = 50 kHz do 100 kHz 0,1 V do 1 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 28 µV\nf = 50 kHz do 100 kHz 1 V do 10 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV\nf = 50 kHz do 100 kHz 10 V do 33 V CMC 15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV\nf = 100 kHz do 300 kHz 0,2 mV do 10 mV CMC 460 · 10⁻⁴ · U + 2,2 µV\nf = 100 kHz do 300 kHz 0,01 V do 0,1 V CMC 35 · 10⁻⁴ · U + 15 µV\nf = 100 kHz do 300 kHz 0,1 V do 1 V CMC 35 · 10⁻⁴ · U + 0,1 mV\nf = 100 kHz do 300 kHz 1 V do 10 V CMC 35 · 10⁻⁴ · U + 1,1 mV\nf = 100 kHz do 300 kHz 10 V do 33 V CMC 44 · 10⁻⁴ · U + 14 mV\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) E /I 1/ MAP Mierniki napiecia analogowe Wzorcowanie — Napiecie AC\nZakres:\nf = 10 Hz do 40 Hz 0,2 mV do 10 mV CMC 34 · 10⁻⁵ · U + 3,5 µV\nf = 10 Hz do 40 Hz 0,01 V do 0,1 V CMC 8 · 10⁻⁵ · U + 4,5 µV\nf = 10 Hz do 40 Hz 0,1 V do 1 V CMC 8 · 10⁻⁵ · U + 45 µV\nf = 10 Hz do 40 Hz 1 V do 10 V CMC 8 · 10⁻⁵ · U + 0,4 mV\nf = 10 Hz do 40 Hz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 4,7 mV\nf = 10 Hz do 40 Hz 100 V do 1000 V CMC 46 · 10⁻⁵ · U + 46 mV\nf = 40 Hz do 1 kHz 0,2 mV do 10 mV CMC 23 · 10⁻⁵ · U + 1,3 µV\nf = 40 Hz do 1 kHz 0,01 V do 0,1 V CMC 8 · 10⁻⁵ · U + 2,3 µV\nf = 40 Hz do 1 kHz 0,1 V do 1 V CMC 8 · 10⁻⁵ · U + 23 µV\nf = 40 Hz do 1 kHz 1 V do 10 V CMC 8 · 10⁻⁵ · U + 0,2 mV\nf = 40 Hz do 1 kHz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 2,3 mV\nf = 40 Hz do 1 kHz 100 V do 1000 V CMC 46 · 10⁻⁵ · U + 23 mV\nf = 1 kHz do 20 kHz 0,2 mV do 10 mV CMC 34 · 10⁻⁵ · U + 1,3 µV\nf = 1 kHz do 20 kHz 0,01 V do 0,1 V CMC 16 · 10⁻⁵ · U + 2,3 µV\nf = 1 kHz do 20 kHz 0,1 V do 1 V CMC 16 · 10⁻⁵ · U + 23 µV\nf = 1 kHz do 20 kHz 1 V do 10 V CMC 16 · 10⁻⁵ · U + 0,4 mV\nf = 1 kHz do 20 kHz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 2,3 mV\nf = 1 kHz do 20 kHz 100 V do 1000 V CMC 69 · 10⁻⁵ · U + 23 mV\nf = 50 kHz do 100 kHz 0,2 mV do 10 mV CMC 58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV\nf = 50 kHz do 100 kHz 0,01 V do 0,1 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV\nf = 50 kHz do 100 kHz 0,1 V do 1 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 28 µV\nf = 50 kHz do 100 kHz 1 V do 10 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV\nf = 50 kHz do 100 kHz 10 V do 33 V CMC 15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV\nf = 100 kHz do 300 kHz 0,2 mV do 10 mV CMC 460 · 10⁻⁴ · U + 2,2 µV\nf = 100 kHz do 300 kHz 0,01 V do 0,1 V CMC 35 · 10⁻⁴ · U + 15 µV\nf = 100 kHz do 300 kHz 0,1 V do 1 V CMC 35 · 10⁻⁴ · U + 0,1 mV\nf = 100 kHz do 300 kHz 1 V do 10 V CMC 35 · 10⁻⁴ · U + 1,1 mV\nf = 100 kHz do 300 kHz 10 V do 33 V CMC 44 · 10⁻⁴ · U + 14 mV\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) E /I 1/ MAP","search_en":"Analogue voltmeters Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) AC voltage Internal procedure Direct method At permanent location (S) f = 10 Hz to 40 Hz f = 10 Hz to 40 Hz f = 10 Hz to 40 Hz f = 10 Hz to 40 Hz f = 10 Hz to 40 Hz f = 10 Hz to 40 Hz f = 40 Hz to 1 kHz f = 40 Hz to 1 kHz f = 40 Hz to 1 kHz f = 40 Hz to 1 kHz f = 40 Hz to 1 kHz f = 40 Hz to 1 kHz f = 1 kHz to 20 kHz f = 1 kHz to 20 kHz f = 1 kHz to 20 kHz f = 1 kHz to 20 kHz f = 1 kHz to 20 kHz f = 1 kHz to 20 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 100 kHz to 300 kHz f = 100 kHz to 300 kHz f = 100 kHz to 300 kHz f = 100 kHz to 300 kHz f = 100 kHz to 300 kHz E /I 1/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"f = 10 Hz bis 40 Hz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 3,5 µV"},{"name":"f = 10 Hz bis 40 Hz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 4,5 µV"},{"name":"f = 10 Hz bis 40 Hz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 45 µV"},{"name":"f = 10 Hz bis 40 Hz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 10 Hz bis 40 Hz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 4,7 mV"},{"name":"f = 10 Hz bis 40 Hz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 46 mV"},{"name":"f = 40 Hz bis 1 kHz","range":"0,2 mV to 10 mV","cmc":"23 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 40 Hz bis 1 kHz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 40 Hz bis 1 kHz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 23 µV"},{"name":"f = 40 Hz bis 1 kHz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,2 mV"},{"name":"f = 40 Hz bis 1 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 40 Hz bis 1 kHz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 23 mV"},{"name":"f = 1 kHz bis 20 kHz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 1 kHz bis 20 kHz","range":"0,01 V to 0,1 V","cmc":"16 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 1 kHz bis 20 kHz","range":"0,1 V to 1 V","cmc":"16 · 10⁻⁵ · U + 23 µV"},{"name":"f = 1 kHz bis 20 kHz","range":"1 V to 10 V","cmc":"16 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 1 kHz bis 20 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 1 kHz bis 20 kHz","range":"100 V to 1000 V","cmc":"69 · 10⁻⁵ · U + 23 mV"},{"name":"f = 50 kHz bis 100 kHz","range":"0,2 mV to 10 mV","cmc":"58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV"},{"name":"f = 50 kHz bis 100 kHz","range":"0,01 V to 0,1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV"},{"name":"f = 50 kHz bis 100 kHz","range":"0,1 V to 1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 28 µV"},{"name":"f = 50 kHz bis 100 kHz","range":"1 V to 10 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV"},{"name":"f = 50 kHz bis 100 kHz","range":"10 V to 33 V","cmc":"15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV"},{"name":"f = 100 kHz bis 300 kHz","range":"0,2 mV to 10 mV","cmc":"460 · 10⁻⁴ · U + 2,2 µV"},{"name":"f = 100 kHz bis 300 kHz","range":"0,01 V to 0,1 V","cmc":"35 · 10⁻⁴ · U + 15 µV"},{"name":"f = 100 kHz bis 300 kHz","range":"0,1 V to 1 V","cmc":"35 · 10⁻⁴ · U + 0,1 mV"},{"name":"f = 100 kHz bis 300 kHz","range":"1 V to 10 V","cmc":"35 · 10⁻⁴ · U + 1,1 mV"},{"name":"f = 100 kHz bis 300 kHz","range":"10 V to 33 V","cmc":"44 · 10⁻⁴ · U + 14 mV"}],"regulatory_area_de":"AC-Spannung","search_de":"Analoge Spannungsmessgeräte Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) f = 10 Hz bis 40 Hz f = 10 Hz bis 40 Hz f = 10 Hz bis 40 Hz f = 10 Hz bis 40 Hz f = 10 Hz bis 40 Hz f = 10 Hz bis 40 Hz f = 40 Hz bis 1 kHz f = 40 Hz bis 1 kHz f = 40 Hz bis 1 kHz f = 40 Hz bis 1 kHz f = 40 Hz bis 1 kHz f = 40 Hz bis 1 kHz f = 1 kHz bis 20 kHz f = 1 kHz bis 20 kHz f = 1 kHz bis 20 kHz f = 1 kHz bis 20 kHz f = 1 kHz bis 20 kHz f = 1 kHz bis 20 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 100 kHz bis 300 kHz f = 100 kHz bis 300 kHz f = 100 kHz bis 300 kHz f = 100 kHz bis 300 kHz f = 100 kHz bis 300 kHz E /I 1/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Spannungsmessgeräte","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"f = 10 Hz 至 40 Hz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 3,5 µV"},{"name":"f = 10 Hz 至 40 Hz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 4,5 µV"},{"name":"f = 10 Hz 至 40 Hz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 45 µV"},{"name":"f = 10 Hz 至 40 Hz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 10 Hz 至 40 Hz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 4,7 mV"},{"name":"f = 10 Hz 至 40 Hz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 46 mV"},{"name":"f = 40 Hz 至 1 kHz","range":"0,2 mV to 10 mV","cmc":"23 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 40 Hz 至 1 kHz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 40 Hz 至 1 kHz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 23 µV"},{"name":"f = 40 Hz 至 1 kHz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,2 mV"},{"name":"f = 40 Hz 至 1 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 40 Hz 至 1 kHz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 23 mV"},{"name":"f = 1 kHz 至 20 kHz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 1 kHz 至 20 kHz","range":"0,01 V to 0,1 V","cmc":"16 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 1 kHz 至 20 kHz","range":"0,1 V to 1 V","cmc":"16 · 10⁻⁵ · U + 23 µV"},{"name":"f = 1 kHz 至 20 kHz","range":"1 V to 10 V","cmc":"16 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 1 kHz 至 20 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 1 kHz 至 20 kHz","range":"100 V to 1000 V","cmc":"69 · 10⁻⁵ · U + 23 mV"},{"name":"f = 50 kHz 至 100 kHz","range":"0,2 mV to 10 mV","cmc":"58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV"},{"name":"f = 50 kHz 至 100 kHz","range":"0,01 V to 0,1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV"},{"name":"f = 50 kHz 至 100 kHz","range":"0,1 V to 1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 28 µV"},{"name":"f = 50 kHz 至 100 kHz","range":"1 V to 10 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV"},{"name":"f = 50 kHz 至 100 kHz","range":"10 V to 33 V","cmc":"15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV"},{"name":"f = 100 kHz 至 300 kHz","range":"0,2 mV to 10 mV","cmc":"460 · 10⁻⁴ · U + 2,2 µV"},{"name":"f = 100 kHz 至 300 kHz","range":"0,01 V to 0,1 V","cmc":"35 · 10⁻⁴ · U + 15 µV"},{"name":"f = 100 kHz 至 300 kHz","range":"0,1 V to 1 V","cmc":"35 · 10⁻⁴ · U + 0,1 mV"},{"name":"f = 100 kHz 至 300 kHz","range":"1 V to 10 V","cmc":"35 · 10⁻⁴ · U + 1,1 mV"},{"name":"f = 100 kHz 至 300 kHz","range":"10 V to 33 V","cmc":"44 · 10⁻⁴ · U + 14 mV"}],"regulatory_area_zh":"交流电压","search_zh":"模拟电压表 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 交流电压 内部程序 直接法 在固定地点 (S) f = 10 Hz 至 40 Hz f = 10 Hz 至 40 Hz f = 10 Hz 至 40 Hz f = 10 Hz 至 40 Hz f = 10 Hz 至 40 Hz f = 10 Hz 至 40 Hz f = 40 Hz 至 1 kHz f = 40 Hz 至 1 kHz f = 40 Hz 至 1 kHz f = 40 Hz 至 1 kHz f = 40 Hz 至 1 kHz f = 40 Hz 至 1 kHz f = 1 kHz 至 20 kHz f = 1 kHz 至 20 kHz f = 1 kHz 至 20 kHz f = 1 kHz 至 20 kHz f = 1 kHz 至 20 kHz f = 1 kHz 至 20 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 100 kHz 至 300 kHz f = 100 kHz 至 300 kHz f = 100 kHz 至 300 kHz f = 100 kHz 至 300 kHz f = 100 kHz 至 300 kHz E /I 1/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"模拟电压表","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"f = 10 Hz až 40 Hz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 3,5 µV"},{"name":"f = 10 Hz až 40 Hz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 4,5 µV"},{"name":"f = 10 Hz až 40 Hz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 45 µV"},{"name":"f = 10 Hz až 40 Hz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 10 Hz až 40 Hz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 4,7 mV"},{"name":"f = 10 Hz až 40 Hz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 46 mV"},{"name":"f = 40 Hz až 1 kHz","range":"0,2 mV to 10 mV","cmc":"23 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 40 Hz až 1 kHz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 40 Hz až 1 kHz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 23 µV"},{"name":"f = 40 Hz až 1 kHz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,2 mV"},{"name":"f = 40 Hz až 1 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 40 Hz až 1 kHz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 23 mV"},{"name":"f = 1 kHz až 20 kHz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 1 kHz až 20 kHz","range":"0,01 V to 0,1 V","cmc":"16 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 1 kHz až 20 kHz","range":"0,1 V to 1 V","cmc":"16 · 10⁻⁵ · U + 23 µV"},{"name":"f = 1 kHz až 20 kHz","range":"1 V to 10 V","cmc":"16 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 1 kHz až 20 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 1 kHz až 20 kHz","range":"100 V to 1000 V","cmc":"69 · 10⁻⁵ · U + 23 mV"},{"name":"f = 50 kHz až 100 kHz","range":"0,2 mV to 10 mV","cmc":"58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV"},{"name":"f = 50 kHz až 100 kHz","range":"0,01 V to 0,1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV"},{"name":"f = 50 kHz až 100 kHz","range":"0,1 V to 1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 28 µV"},{"name":"f = 50 kHz až 100 kHz","range":"1 V to 10 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV"},{"name":"f = 50 kHz až 100 kHz","range":"10 V to 33 V","cmc":"15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV"},{"name":"f = 100 kHz až 300 kHz","range":"0,2 mV to 10 mV","cmc":"460 · 10⁻⁴ · U + 2,2 µV"},{"name":"f = 100 kHz až 300 kHz","range":"0,01 V to 0,1 V","cmc":"35 · 10⁻⁴ · U + 15 µV"},{"name":"f = 100 kHz až 300 kHz","range":"0,1 V to 1 V","cmc":"35 · 10⁻⁴ · U + 0,1 mV"},{"name":"f = 100 kHz až 300 kHz","range":"1 V to 10 V","cmc":"35 · 10⁻⁴ · U + 1,1 mV"},{"name":"f = 100 kHz až 300 kHz","range":"10 V to 33 V","cmc":"44 · 10⁻⁴ · U + 14 mV"}],"regulatory_area_cs":"Napětí AC","search_cs":"Analogové měřiče napětí Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Napětí AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) f = 10 Hz až 40 Hz f = 10 Hz až 40 Hz f = 10 Hz až 40 Hz f = 10 Hz až 40 Hz f = 10 Hz až 40 Hz f = 10 Hz až 40 Hz f = 40 Hz až 1 kHz f = 40 Hz až 1 kHz f = 40 Hz až 1 kHz f = 40 Hz až 1 kHz f = 40 Hz až 1 kHz f = 40 Hz až 1 kHz f = 1 kHz až 20 kHz f = 1 kHz až 20 kHz f = 1 kHz až 20 kHz f = 1 kHz až 20 kHz f = 1 kHz až 20 kHz f = 1 kHz až 20 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 100 kHz až 300 kHz f = 100 kHz až 300 kHz f = 100 kHz až 300 kHz f = 100 kHz až 300 kHz f = 100 kHz až 300 kHz E /I 1/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče napětí"},{"_id":"1ea51ba6e76db559c6442b77","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki napięcia cyfrowe\nMultimetry\nKalibratory","test_object_en":"Digital voltmeters\nMultimeters\nCalibrators","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"f = 10 Hz do 40 Hz","range":"0,2 mV do 10 mV","cmc":"34 · 10⁻⁵ · U + 3,5 µV"},{"name":"f = 10 Hz do 40 Hz","range":"0,01 V do 0,1 V","cmc":"8 · 10⁻⁵ · U + 4,5 µV"},{"name":"f = 10 Hz do 40 Hz","range":"0,1 V do 1 V","cmc":"8 · 10⁻⁵ · U + 45 µV"},{"name":"f = 10 Hz do 40 Hz","range":"1 V do 10 V","cmc":"8 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 10 Hz do 40 Hz","range":"10 V do 100 V","cmc":"23 · 10⁻⁵ · U + 4,7 mV"},{"name":"f = 10 Hz do 40 Hz","range":"100 V do 1000 V","cmc":"46 · 10⁻⁵ · U + 46 mV"},{"name":"f = 40 Hz do 1 kHz","range":"0,2 mV do 10 mV","cmc":"23 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 40 Hz do 1 kHz","range":"0,01 V do 0,1 V","cmc":"8 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 40 Hz do 1 kHz","range":"0,1 V do 1 V","cmc":"8 · 10⁻⁵ · U + 23 µV"},{"name":"f = 40 Hz do 1 kHz","range":"1 V do 10 V","cmc":"8 · 10⁻⁵ · U + 0,2 mV"},{"name":"f = 40 Hz do 1 kHz","range":"10 V do 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 40 Hz do 1 kHz","range":"100 V do 1000 V","cmc":"46 · 10⁻⁵ · U + 23 mV"},{"name":"f = 1 kHz do 20 kHz","range":"0,2 mV do 10 mV","cmc":"34 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 1 kHz do 20 kHz","range":"0,01 V do 0,1 V","cmc":"16 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 1 kHz do 20 kHz","range":"0,1 V do 1 V","cmc":"16 · 10⁻⁵ · U + 23 µV"},{"name":"f = 1 kHz do 20 kHz","range":"1 V do 10 V","cmc":"16 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 1 kHz do 20 kHz","range":"10 V do 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 1 kHz do 20 kHz","range":"100 V do 1000 V","cmc":"69 · 10⁻⁵ · U + 23 mV"},{"name":"f = 50 kHz do 100 kHz","range":"0,2 mV do 10 mV","cmc":"58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV"},{"name":"f = 50 kHz do 100 kHz","range":"0,01 V do 0,1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV"},{"name":"f = 50 kHz do 100 kHz","range":"0,1 V do 1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 28 µV"},{"name":"f = 50 kHz do 100 kHz","range":"1 V do 10 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV"},{"name":"f = 50 kHz do 100 kHz","range":"10 V do 33 V","cmc":"15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV"},{"name":"f = 100 kHz do 300 kHz","range":"0,2 mV do 10 mV","cmc":"460 · 10⁻⁴ · U + 2,2 µV"},{"name":"f = 100 kHz do 300 kHz","range":"0,01 V do 0,1 V","cmc":"35 · 10⁻⁴ · U + 15 µV"},{"name":"f = 100 kHz do 300 kHz","range":"0,1 V do 1 V","cmc":"35 · 10⁻⁴ · U + 0,1 mV"},{"name":"f = 100 kHz do 300 kHz","range":"1 V do 10 V","cmc":"35 · 10⁻⁴ · U + 1,1 mV"},{"name":"f = 100 kHz do 300 kHz","range":"10 V do 33 V","cmc":"44 · 10⁻⁴ · U + 14 mV"}],"parameters_en":[{"name":"f = 10 Hz to 40 Hz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 3,5 µV"},{"name":"f = 10 Hz to 40 Hz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 4,5 µV"},{"name":"f = 10 Hz to 40 Hz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 45 µV"},{"name":"f = 10 Hz to 40 Hz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 10 Hz to 40 Hz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 4,7 mV"},{"name":"f = 10 Hz to 40 Hz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 46 mV"},{"name":"f = 40 Hz to 1 kHz","range":"0,2 mV to 10 mV","cmc":"23 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 40 Hz to 1 kHz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 40 Hz to 1 kHz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 23 µV"},{"name":"f = 40 Hz to 1 kHz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,2 mV"},{"name":"f = 40 Hz to 1 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 40 Hz to 1 kHz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 23 mV"},{"name":"f = 1 kHz to 20 kHz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 1 kHz to 20 kHz","range":"0,01 V to 0,1 V","cmc":"16 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 1 kHz to 20 kHz","range":"0,1 V to 1 V","cmc":"16 · 10⁻⁵ · U + 23 µV"},{"name":"f = 1 kHz to 20 kHz","range":"1 V to 10 V","cmc":"16 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 1 kHz to 20 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 1 kHz to 20 kHz","range":"100 V to 1000 V","cmc":"69 · 10⁻⁵ · U + 23 mV"},{"name":"f = 50 kHz to 100 kHz","range":"0,2 mV to 10 mV","cmc":"58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV"},{"name":"f = 50 kHz to 100 kHz","range":"0,01 V to 0,1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV"},{"name":"f = 50 kHz to 100 kHz","range":"0,1 V to 1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 28 µV"},{"name":"f = 50 kHz to 100 kHz","range":"1 V to 10 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV"},{"name":"f = 50 kHz to 100 kHz","range":"10 V to 33 V","cmc":"15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV"},{"name":"f = 100 kHz to 300 kHz","range":"0,2 mV to 10 mV","cmc":"460 · 10⁻⁴ · U + 2,2 µV"},{"name":"f = 100 kHz to 300 kHz","range":"0,01 V to 0,1 V","cmc":"35 · 10⁻⁴ · U + 15 µV"},{"name":"f = 100 kHz to 300 kHz","range":"0,1 V to 1 V","cmc":"35 · 10⁻⁴ · U + 0,1 mV"},{"name":"f = 100 kHz to 300 kHz","range":"1 V to 10 V","cmc":"35 · 10⁻⁴ · U + 1,1 mV"},{"name":"f = 100 kHz to 300 kHz","range":"10 V to 33 V","cmc":"44 · 10⁻⁴ · U + 14 mV"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","technique_en":"Direct and indirect method; At permanent location (S)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Direct and indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\nf = 10 Hz do 40 Hz 0,2 mV do 10 mV CMC 34 · 10⁻⁵ · U + 3,5 µV\nf = 10 Hz do 40 Hz 0,01 V do 0,1 V CMC 8 · 10⁻⁵ · U + 4,5 µV\nf = 10 Hz do 40 Hz 0,1 V do 1 V CMC 8 · 10⁻⁵ · U + 45 µV\nf = 10 Hz do 40 Hz 1 V do 10 V CMC 8 · 10⁻⁵ · U + 0,4 mV\nf = 10 Hz do 40 Hz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 4,7 mV\nf = 10 Hz do 40 Hz 100 V do 1000 V CMC 46 · 10⁻⁵ · U + 46 mV\nf = 40 Hz do 1 kHz 0,2 mV do 10 mV CMC 23 · 10⁻⁵ · U + 1,3 µV\nf = 40 Hz do 1 kHz 0,01 V do 0,1 V CMC 8 · 10⁻⁵ · U + 2,3 µV\nf = 40 Hz do 1 kHz 0,1 V do 1 V CMC 8 · 10⁻⁵ · U + 23 µV\nf = 40 Hz do 1 kHz 1 V do 10 V CMC 8 · 10⁻⁵ · U + 0,2 mV\nf = 40 Hz do 1 kHz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 2,3 mV\nf = 40 Hz do 1 kHz 100 V do 1000 V CMC 46 · 10⁻⁵ · U + 23 mV\nf = 1 kHz do 20 kHz 0,2 mV do 10 mV CMC 34 · 10⁻⁵ · U + 1,3 µV\nf = 1 kHz do 20 kHz 0,01 V do 0,1 V CMC 16 · 10⁻⁵ · U + 2,3 µV\nf = 1 kHz do 20 kHz 0,1 V do 1 V CMC 16 · 10⁻⁵ · U + 23 µV\nf = 1 kHz do 20 kHz 1 V do 10 V CMC 16 · 10⁻⁵ · U + 0,4 mV\nf = 1 kHz do 20 kHz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 2,3 mV\nf = 1 kHz do 20 kHz 100 V do 1000 V CMC 69 · 10⁻⁵ · U + 23 mV\nf = 50 kHz do 100 kHz 0,2 mV do 10 mV CMC 58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV\nf = 50 kHz do 100 kHz 0,01 V do 0,1 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV\nf = 50 kHz do 100 kHz 0,1 V do 1 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 28 µV\nf = 50 kHz do 100 kHz 1 V do 10 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV\nf = 50 kHz do 100 kHz 10 V do 33 V CMC 15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV\nf = 100 kHz do 300 kHz 0,2 mV do 10 mV CMC 460 · 10⁻⁴ · U + 2,2 µV\nf = 100 kHz do 300 kHz 0,01 V do 0,1 V CMC 35 · 10⁻⁴ · U + 15 µV\nf = 100 kHz do 300 kHz 0,1 V do 1 V CMC 35 · 10⁻⁴ · U + 0,1 mV\nf = 100 kHz do 300 kHz 1 V do 10 V CMC 35 · 10⁻⁴ · U + 1,1 mV\nf = 100 kHz do 300 kHz 10 V do 33 V CMC 44 · 10⁻⁴ · U + 14 mV\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":"U – wielkość mierzona (V)","note_en":"U – measured value (V)","search_text":"Mierniki napięcia cyfrowe\nMultimetry\nKalibratory Wzorcowanie — Napięcie AC\nZakres:\nf = 10 Hz do 40 Hz 0,2 mV do 10 mV CMC 34 · 10⁻⁵ · U + 3,5 µV\nf = 10 Hz do 40 Hz 0,01 V do 0,1 V CMC 8 · 10⁻⁵ · U + 4,5 µV\nf = 10 Hz do 40 Hz 0,1 V do 1 V CMC 8 · 10⁻⁵ · U + 45 µV\nf = 10 Hz do 40 Hz 1 V do 10 V CMC 8 · 10⁻⁵ · U + 0,4 mV\nf = 10 Hz do 40 Hz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 4,7 mV\nf = 10 Hz do 40 Hz 100 V do 1000 V CMC 46 · 10⁻⁵ · U + 46 mV\nf = 40 Hz do 1 kHz 0,2 mV do 10 mV CMC 23 · 10⁻⁵ · U + 1,3 µV\nf = 40 Hz do 1 kHz 0,01 V do 0,1 V CMC 8 · 10⁻⁵ · U + 2,3 µV\nf = 40 Hz do 1 kHz 0,1 V do 1 V CMC 8 · 10⁻⁵ · U + 23 µV\nf = 40 Hz do 1 kHz 1 V do 10 V CMC 8 · 10⁻⁵ · U + 0,2 mV\nf = 40 Hz do 1 kHz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 2,3 mV\nf = 40 Hz do 1 kHz 100 V do 1000 V CMC 46 · 10⁻⁵ · U + 23 mV\nf = 1 kHz do 20 kHz 0,2 mV do 10 mV CMC 34 · 10⁻⁵ · U + 1,3 µV\nf = 1 kHz do 20 kHz 0,01 V do 0,1 V CMC 16 · 10⁻⁵ · U + 2,3 µV\nf = 1 kHz do 20 kHz 0,1 V do 1 V CMC 16 · 10⁻⁵ · U + 23 µV\nf = 1 kHz do 20 kHz 1 V do 10 V CMC 16 · 10⁻⁵ · U + 0,4 mV\nf = 1 kHz do 20 kHz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 2,3 mV\nf = 1 kHz do 20 kHz 100 V do 1000 V CMC 69 · 10⁻⁵ · U + 23 mV\nf = 50 kHz do 100 kHz 0,2 mV do 10 mV CMC 58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV\nf = 50 kHz do 100 kHz 0,01 V do 0,1 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV\nf = 50 kHz do 100 kHz 0,1 V do 1 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 28 µV\nf = 50 kHz do 100 kHz 1 V do 10 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV\nf = 50 kHz do 100 kHz 10 V do 33 V CMC 15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV\nf = 100 kHz do 300 kHz 0,2 mV do 10 mV CMC 460 · 10⁻⁴ · U + 2,2 µV\nf = 100 kHz do 300 kHz 0,01 V do 0,1 V CMC 35 · 10⁻⁴ · U + 15 µV\nf = 100 kHz do 300 kHz 0,1 V do 1 V CMC 35 · 10⁻⁴ · U + 0,1 mV\nf = 100 kHz do 300 kHz 1 V do 10 V CMC 35 · 10⁻⁴ · U + 1,1 mV\nf = 100 kHz do 300 kHz 10 V do 33 V CMC 44 · 10⁻⁴ · U + 14 mV\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) EURAMET cg-15 v.3.0 Mierniki napiecia cyfrowe\nMultimetry\nKalibratory Wzorcowanie — Napiecie AC\nZakres:\nf = 10 Hz do 40 Hz 0,2 mV do 10 mV CMC 34 · 10⁻⁵ · U + 3,5 µV\nf = 10 Hz do 40 Hz 0,01 V do 0,1 V CMC 8 · 10⁻⁵ · U + 4,5 µV\nf = 10 Hz do 40 Hz 0,1 V do 1 V CMC 8 · 10⁻⁵ · U + 45 µV\nf = 10 Hz do 40 Hz 1 V do 10 V CMC 8 · 10⁻⁵ · U + 0,4 mV\nf = 10 Hz do 40 Hz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 4,7 mV\nf = 10 Hz do 40 Hz 100 V do 1000 V CMC 46 · 10⁻⁵ · U + 46 mV\nf = 40 Hz do 1 kHz 0,2 mV do 10 mV CMC 23 · 10⁻⁵ · U + 1,3 µV\nf = 40 Hz do 1 kHz 0,01 V do 0,1 V CMC 8 · 10⁻⁵ · U + 2,3 µV\nf = 40 Hz do 1 kHz 0,1 V do 1 V CMC 8 · 10⁻⁵ · U + 23 µV\nf = 40 Hz do 1 kHz 1 V do 10 V CMC 8 · 10⁻⁵ · U + 0,2 mV\nf = 40 Hz do 1 kHz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 2,3 mV\nf = 40 Hz do 1 kHz 100 V do 1000 V CMC 46 · 10⁻⁵ · U + 23 mV\nf = 1 kHz do 20 kHz 0,2 mV do 10 mV CMC 34 · 10⁻⁵ · U + 1,3 µV\nf = 1 kHz do 20 kHz 0,01 V do 0,1 V CMC 16 · 10⁻⁵ · U + 2,3 µV\nf = 1 kHz do 20 kHz 0,1 V do 1 V CMC 16 · 10⁻⁵ · U + 23 µV\nf = 1 kHz do 20 kHz 1 V do 10 V CMC 16 · 10⁻⁵ · U + 0,4 mV\nf = 1 kHz do 20 kHz 10 V do 100 V CMC 23 · 10⁻⁵ · U + 2,3 mV\nf = 1 kHz do 20 kHz 100 V do 1000 V CMC 69 · 10⁻⁵ · U + 23 mV\nf = 50 kHz do 100 kHz 0,2 mV do 10 mV CMC 58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV\nf = 50 kHz do 100 kHz 0,01 V do 0,1 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV\nf = 50 kHz do 100 kHz 0,1 V do 1 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 28 µV\nf = 50 kHz do 100 kHz 1 V do 10 V CMC 9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV\nf = 50 kHz do 100 kHz 10 V do 33 V CMC 15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV\nf = 100 kHz do 300 kHz 0,2 mV do 10 mV CMC 460 · 10⁻⁴ · U + 2,2 µV\nf = 100 kHz do 300 kHz 0,01 V do 0,1 V CMC 35 · 10⁻⁴ · U + 15 µV\nf = 100 kHz do 300 kHz 0,1 V do 1 V CMC 35 · 10⁻⁴ · U + 0,1 mV\nf = 100 kHz do 300 kHz 1 V do 10 V CMC 35 · 10⁻⁴ · U + 1,1 mV\nf = 100 kHz do 300 kHz 10 V do 33 V CMC 44 · 10⁻⁴ · U + 14 mV\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) EURAMET cg-15 v.3.0","search_en":"Digital voltmeters Multimeters Calibrators Calibration — AC voltage Direct and indirect method; At permanent location (S) AC voltage Direct and indirect method At permanent location (S) f = 10 Hz to 40 Hz f = 10 Hz to 40 Hz f = 10 Hz to 40 Hz f = 10 Hz to 40 Hz f = 10 Hz to 40 Hz f = 10 Hz to 40 Hz f = 40 Hz to 1 kHz f = 40 Hz to 1 kHz f = 40 Hz to 1 kHz f = 40 Hz to 1 kHz f = 40 Hz to 1 kHz f = 40 Hz to 1 kHz f = 1 kHz to 20 kHz f = 1 kHz to 20 kHz f = 1 kHz to 20 kHz f = 1 kHz to 20 kHz f = 1 kHz to 20 kHz f = 1 kHz to 20 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 100 kHz to 300 kHz f = 100 kHz to 300 kHz f = 100 kHz to 300 kHz f = 100 kHz to 300 kHz f = 100 kHz to 300 kHz EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"f = 10 Hz bis 40 Hz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 3,5 µV"},{"name":"f = 10 Hz bis 40 Hz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 4,5 µV"},{"name":"f = 10 Hz bis 40 Hz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 45 µV"},{"name":"f = 10 Hz bis 40 Hz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 10 Hz bis 40 Hz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 4,7 mV"},{"name":"f = 10 Hz bis 40 Hz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 46 mV"},{"name":"f = 40 Hz bis 1 kHz","range":"0,2 mV to 10 mV","cmc":"23 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 40 Hz bis 1 kHz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 40 Hz bis 1 kHz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 23 µV"},{"name":"f = 40 Hz bis 1 kHz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,2 mV"},{"name":"f = 40 Hz bis 1 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 40 Hz bis 1 kHz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 23 mV"},{"name":"f = 1 kHz bis 20 kHz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 1 kHz bis 20 kHz","range":"0,01 V to 0,1 V","cmc":"16 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 1 kHz bis 20 kHz","range":"0,1 V to 1 V","cmc":"16 · 10⁻⁵ · U + 23 µV"},{"name":"f = 1 kHz bis 20 kHz","range":"1 V to 10 V","cmc":"16 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 1 kHz bis 20 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 1 kHz bis 20 kHz","range":"100 V to 1000 V","cmc":"69 · 10⁻⁵ · U + 23 mV"},{"name":"f = 50 kHz bis 100 kHz","range":"0,2 mV to 10 mV","cmc":"58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV"},{"name":"f = 50 kHz bis 100 kHz","range":"0,01 V to 0,1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV"},{"name":"f = 50 kHz bis 100 kHz","range":"0,1 V to 1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 28 µV"},{"name":"f = 50 kHz bis 100 kHz","range":"1 V to 10 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV"},{"name":"f = 50 kHz bis 100 kHz","range":"10 V to 33 V","cmc":"15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV"},{"name":"f = 100 kHz bis 300 kHz","range":"0,2 mV to 10 mV","cmc":"460 · 10⁻⁴ · U + 2,2 µV"},{"name":"f = 100 kHz bis 300 kHz","range":"0,01 V to 0,1 V","cmc":"35 · 10⁻⁴ · U + 15 µV"},{"name":"f = 100 kHz bis 300 kHz","range":"0,1 V to 1 V","cmc":"35 · 10⁻⁴ · U + 0,1 mV"},{"name":"f = 100 kHz bis 300 kHz","range":"1 V to 10 V","cmc":"35 · 10⁻⁴ · U + 1,1 mV"},{"name":"f = 100 kHz bis 300 kHz","range":"10 V to 33 V","cmc":"44 · 10⁻⁴ · U + 14 mV"}],"regulatory_area_de":"AC-Spannung","search_de":"Digitale Spannungsmessgeräte Multimeter Kalibratoren Kalibrierung — Wechselspannung Direktes und indirektes Verfahren; Am festen Standort (S) AC-Spannung Direktes und indirektes Verfahren Am festen Standort (S) f = 10 Hz bis 40 Hz f = 10 Hz bis 40 Hz f = 10 Hz bis 40 Hz f = 10 Hz bis 40 Hz f = 10 Hz bis 40 Hz f = 10 Hz bis 40 Hz f = 40 Hz bis 1 kHz f = 40 Hz bis 1 kHz f = 40 Hz bis 1 kHz f = 40 Hz bis 1 kHz f = 40 Hz bis 1 kHz f = 40 Hz bis 1 kHz f = 1 kHz bis 20 kHz f = 1 kHz bis 20 kHz f = 1 kHz bis 20 kHz f = 1 kHz bis 20 kHz f = 1 kHz bis 20 kHz f = 1 kHz bis 20 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 100 kHz bis 300 kHz f = 100 kHz bis 300 kHz f = 100 kHz bis 300 kHz f = 100 kHz bis 300 kHz f = 100 kHz bis 300 kHz EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Spannungsmessgeräte\nMultimeter\nKalibratoren","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"f = 10 Hz 至 40 Hz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 3,5 µV"},{"name":"f = 10 Hz 至 40 Hz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 4,5 µV"},{"name":"f = 10 Hz 至 40 Hz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 45 µV"},{"name":"f = 10 Hz 至 40 Hz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 10 Hz 至 40 Hz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 4,7 mV"},{"name":"f = 10 Hz 至 40 Hz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 46 mV"},{"name":"f = 40 Hz 至 1 kHz","range":"0,2 mV to 10 mV","cmc":"23 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 40 Hz 至 1 kHz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 40 Hz 至 1 kHz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 23 µV"},{"name":"f = 40 Hz 至 1 kHz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,2 mV"},{"name":"f = 40 Hz 至 1 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 40 Hz 至 1 kHz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 23 mV"},{"name":"f = 1 kHz 至 20 kHz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 1 kHz 至 20 kHz","range":"0,01 V to 0,1 V","cmc":"16 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 1 kHz 至 20 kHz","range":"0,1 V to 1 V","cmc":"16 · 10⁻⁵ · U + 23 µV"},{"name":"f = 1 kHz 至 20 kHz","range":"1 V to 10 V","cmc":"16 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 1 kHz 至 20 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 1 kHz 至 20 kHz","range":"100 V to 1000 V","cmc":"69 · 10⁻⁵ · U + 23 mV"},{"name":"f = 50 kHz 至 100 kHz","range":"0,2 mV to 10 mV","cmc":"58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV"},{"name":"f = 50 kHz 至 100 kHz","range":"0,01 V to 0,1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV"},{"name":"f = 50 kHz 至 100 kHz","range":"0,1 V to 1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 28 µV"},{"name":"f = 50 kHz 至 100 kHz","range":"1 V to 10 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV"},{"name":"f = 50 kHz 至 100 kHz","range":"10 V to 33 V","cmc":"15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV"},{"name":"f = 100 kHz 至 300 kHz","range":"0,2 mV to 10 mV","cmc":"460 · 10⁻⁴ · U + 2,2 µV"},{"name":"f = 100 kHz 至 300 kHz","range":"0,01 V to 0,1 V","cmc":"35 · 10⁻⁴ · U + 15 µV"},{"name":"f = 100 kHz 至 300 kHz","range":"0,1 V to 1 V","cmc":"35 · 10⁻⁴ · U + 0,1 mV"},{"name":"f = 100 kHz 至 300 kHz","range":"1 V to 10 V","cmc":"35 · 10⁻⁴ · U + 1,1 mV"},{"name":"f = 100 kHz 至 300 kHz","range":"10 V to 33 V","cmc":"44 · 10⁻⁴ · U + 14 mV"}],"regulatory_area_zh":"交流电压","search_zh":"数字电压表 万用表 校准器 校准 — 交流电压 直接法和间接法; 在固定地点 (S) 交流电压 直接法和间接法 在固定地点 (S) f = 10 Hz 至 40 Hz f = 10 Hz 至 40 Hz f = 10 Hz 至 40 Hz f = 10 Hz 至 40 Hz f = 10 Hz 至 40 Hz f = 10 Hz 至 40 Hz f = 40 Hz 至 1 kHz f = 40 Hz 至 1 kHz f = 40 Hz 至 1 kHz f = 40 Hz 至 1 kHz f = 40 Hz 至 1 kHz f = 40 Hz 至 1 kHz f = 1 kHz 至 20 kHz f = 1 kHz 至 20 kHz f = 1 kHz 至 20 kHz f = 1 kHz 至 20 kHz f = 1 kHz 至 20 kHz f = 1 kHz 至 20 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 100 kHz 至 300 kHz f = 100 kHz 至 300 kHz f = 100 kHz 至 300 kHz f = 100 kHz 至 300 kHz f = 100 kHz 至 300 kHz EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法; 在固定地点 (S)","techniques_zh":["直接法和间接法","在固定地点 (S)"],"test_object_zh":"数字电压表\n万用表\n校准器","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"f = 10 Hz až 40 Hz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 3,5 µV"},{"name":"f = 10 Hz až 40 Hz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 4,5 µV"},{"name":"f = 10 Hz až 40 Hz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 45 µV"},{"name":"f = 10 Hz až 40 Hz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 10 Hz až 40 Hz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 4,7 mV"},{"name":"f = 10 Hz až 40 Hz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 46 mV"},{"name":"f = 40 Hz až 1 kHz","range":"0,2 mV to 10 mV","cmc":"23 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 40 Hz až 1 kHz","range":"0,01 V to 0,1 V","cmc":"8 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 40 Hz až 1 kHz","range":"0,1 V to 1 V","cmc":"8 · 10⁻⁵ · U + 23 µV"},{"name":"f = 40 Hz až 1 kHz","range":"1 V to 10 V","cmc":"8 · 10⁻⁵ · U + 0,2 mV"},{"name":"f = 40 Hz až 1 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 40 Hz až 1 kHz","range":"100 V to 1000 V","cmc":"46 · 10⁻⁵ · U + 23 mV"},{"name":"f = 1 kHz až 20 kHz","range":"0,2 mV to 10 mV","cmc":"34 · 10⁻⁵ · U + 1,3 µV"},{"name":"f = 1 kHz až 20 kHz","range":"0,01 V to 0,1 V","cmc":"16 · 10⁻⁵ · U + 2,3 µV"},{"name":"f = 1 kHz až 20 kHz","range":"0,1 V to 1 V","cmc":"16 · 10⁻⁵ · U + 23 µV"},{"name":"f = 1 kHz až 20 kHz","range":"1 V to 10 V","cmc":"16 · 10⁻⁵ · U + 0,4 mV"},{"name":"f = 1 kHz až 20 kHz","range":"10 V to 100 V","cmc":"23 · 10⁻⁵ · U + 2,3 mV"},{"name":"f = 1 kHz až 20 kHz","range":"100 V to 1000 V","cmc":"69 · 10⁻⁵ · U + 23 mV"},{"name":"f = 50 kHz až 100 kHz","range":"0,2 mV to 10 mV","cmc":"58 · 10⁻⁴ 10⁻⁵ · U + 1,2 µV"},{"name":"f = 50 kHz až 100 kHz","range":"0,01 V to 0,1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 2,8 µV"},{"name":"f = 50 kHz až 100 kHz","range":"0,1 V to 1 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 28 µV"},{"name":"f = 50 kHz až 100 kHz","range":"1 V to 10 V","cmc":"9 · 10⁻⁴ 10⁻⁵ · U + 0,3 mV"},{"name":"f = 50 kHz až 100 kHz","range":"10 V to 33 V","cmc":"15 · 10⁻⁴ 10⁻⁵ · U + 1,2 mV"},{"name":"f = 100 kHz až 300 kHz","range":"0,2 mV to 10 mV","cmc":"460 · 10⁻⁴ · U + 2,2 µV"},{"name":"f = 100 kHz až 300 kHz","range":"0,01 V to 0,1 V","cmc":"35 · 10⁻⁴ · U + 15 µV"},{"name":"f = 100 kHz až 300 kHz","range":"0,1 V to 1 V","cmc":"35 · 10⁻⁴ · U + 0,1 mV"},{"name":"f = 100 kHz až 300 kHz","range":"1 V to 10 V","cmc":"35 · 10⁻⁴ · U + 1,1 mV"},{"name":"f = 100 kHz až 300 kHz","range":"10 V to 33 V","cmc":"44 · 10⁻⁴ · U + 14 mV"}],"regulatory_area_cs":"Napětí AC","search_cs":"Digitální měřiče napětí Multimetry Kalibrátory Kalibrace — Napětí AC Přímá a nepřímá metoda; Ve stálé lokalitě (S) Napětí AC Přímá a nepřímá metoda Ve stálé lokalitě (S) f = 10 Hz až 40 Hz f = 10 Hz až 40 Hz f = 10 Hz až 40 Hz f = 10 Hz až 40 Hz f = 10 Hz až 40 Hz f = 10 Hz až 40 Hz f = 40 Hz až 1 kHz f = 40 Hz až 1 kHz f = 40 Hz až 1 kHz f = 40 Hz až 1 kHz f = 40 Hz až 1 kHz f = 40 Hz až 1 kHz f = 1 kHz až 20 kHz f = 1 kHz až 20 kHz f = 1 kHz až 20 kHz f = 1 kHz až 20 kHz f = 1 kHz až 20 kHz f = 1 kHz až 20 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 100 kHz až 300 kHz f = 100 kHz až 300 kHz f = 100 kHz až 300 kHz f = 100 kHz až 300 kHz f = 100 kHz až 300 kHz EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Přímá a nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální měřiče napětí\nMultimetry\nKalibrátory"},{"_id":"83856f29e2b30ca80a8a140a","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Kalibratory","test_object_en":"Calibrators","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"f = 10 Hz do 20 kHz","range":"0,2 mV do 100 mV","cmc":"69 · 10⁻⁵ · U + 35 µV"},{"name":"f = 10 Hz do 20 kHz","range":"0,1 V do 1 V","cmc":"69 · 10⁻⁵ · U + 0,35 mV"},{"name":"f = 10 Hz do 20 kHz","range":"1 V do 10 V","cmc":"69 · 10⁻⁵ · U + 3,5 mV"},{"name":"f = 10 Hz do 20 kHz","range":"10 V do 100 V","cmc":"69 · 10⁻⁵ · U + 35 mV"},{"name":"f = 10 Hz do 20 kHz","range":"100 V do 750 V","cmc":"69 · 10⁻⁵ · U + 0,26 V"},{"name":"f = 20 kHz do 50 kHz","range":"0,2 mV do 100 mV","cmc":"14 · 10⁻⁴ · U + 58 µV"},{"name":"f = 20 kHz do 50 kHz","range":"0,1 V do 1 V","cmc":"14 · 10⁻⁴ · U + 0,58 mV"},{"name":"f = 20 kHz do 50 kHz","range":"1 V do 10 V","cmc":"14 · 10⁻⁴ · U + 5,8 mV"},{"name":"f = 20 kHz do 50 kHz","range":"10 V do 100 V","cmc":"14 · 10⁻⁴ · U + 58 mV"},{"name":"f = 20 kHz do 50 kHz","range":"100 V do 750 V","cmc":"14 · 10⁻⁴ · U + 0,43 V"},{"name":"f = 50 kHz do 100 kHz","range":"0,2 mV do 100 mV","cmc":"69· 10⁻⁴ · U + 93 µV"},{"name":"f = 50 kHz do 100 kHz","range":"0,1 V do 1 V","cmc":"69 · 10⁻⁴ · U + 0,93 mV"},{"name":"f = 50 kHz do 100 kHz","range":"1 V do 10 V","cmc":"69 · 10⁻⁴ · U + 9,3 mV"},{"name":"f = 50 kHz do 100 kHz","range":"10 V do 33 V","cmc":"69 · 10⁻⁴ · U + 93 mV"},{"name":"f = 100 kHz do 300 kHz","range":"0,2 mV do 100 mV","cmc":"46 · 10⁻³ · U + 0,58 mV"},{"name":"f = 100 kHz do 300 kHz","range":"0,1 V do 1 V","cmc":"46 · 10⁻³ · U + 5,8 mV"},{"name":"f = 100 kHz do 300 kHz","range":"1 V do 10 V","cmc":"46 · 10⁻³ · U + 58 mV"},{"name":"f = 100 kHz do 300 kHz","range":"10 V do 33 V","cmc":"46 · 10⁻³ · U + 0,58 V"}],"parameters_en":[{"name":"f = 10 Hz to 20 kHz","range":"0,2 mV to 100 mV","cmc":"69 · 10⁻⁵ · U + 35 µV"},{"name":"f = 10 Hz to 20 kHz","range":"0,1 V to 1 V","cmc":"69 · 10⁻⁵ · U + 0,35 mV"},{"name":"f = 10 Hz to 20 kHz","range":"1 V to 10 V","cmc":"69 · 10⁻⁵ · U + 3,5 mV"},{"name":"f = 10 Hz to 20 kHz","range":"10 V to 100 V","cmc":"69 · 10⁻⁵ · U + 35 mV"},{"name":"f = 10 Hz to 20 kHz","range":"100 V to 750 V","cmc":"69 · 10⁻⁵ · U + 0,26 V"},{"name":"f = 20 kHz to 50 kHz","range":"0,2 mV to 100 mV","cmc":"14 · 10⁻⁴ · U + 58 µV"},{"name":"f = 20 kHz to 50 kHz","range":"0,1 V to 1 V","cmc":"14 · 10⁻⁴ · U + 0,58 mV"},{"name":"f = 20 kHz to 50 kHz","range":"1 V to 10 V","cmc":"14 · 10⁻⁴ · U + 5,8 mV"},{"name":"f = 20 kHz to 50 kHz","range":"10 V to 100 V","cmc":"14 · 10⁻⁴ · U + 58 mV"},{"name":"f = 20 kHz to 50 kHz","range":"100 V to 750 V","cmc":"14 · 10⁻⁴ · U + 0,43 V"},{"name":"f = 50 kHz to 100 kHz","range":"0,2 mV to 100 mV","cmc":"69· 10⁻⁴ · U + 93 µV"},{"name":"f = 50 kHz to 100 kHz","range":"0,1 V to 1 V","cmc":"69 · 10⁻⁴ · U + 0,93 mV"},{"name":"f = 50 kHz to 100 kHz","range":"1 V to 10 V","cmc":"69 · 10⁻⁴ · U + 9,3 mV"},{"name":"f = 50 kHz to 100 kHz","range":"10 V to 33 V","cmc":"69 · 10⁻⁴ · U + 93 mV"},{"name":"f = 100 kHz to 300 kHz","range":"0,2 mV to 100 mV","cmc":"46 · 10⁻³ · U + 0,58 mV"},{"name":"f = 100 kHz to 300 kHz","range":"0,1 V to 1 V","cmc":"46 · 10⁻³ · U + 5,8 mV"},{"name":"f = 100 kHz to 300 kHz","range":"1 V to 10 V","cmc":"46 · 10⁻³ · U + 58 mV"},{"name":"f = 100 kHz to 300 kHz","range":"10 V to 33 V","cmc":"46 · 10⁻³ · U + 0,58 V"}],"technique":"Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Direct method; Outside of permanent location (P)","techniques":["Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\nf = 10 Hz do 20 kHz 0,2 mV do 100 mV CMC 69 · 10⁻⁵ · U + 35 µV\nf = 10 Hz do 20 kHz 0,1 V do 1 V CMC 69 · 10⁻⁵ · U + 0,35 mV\nf = 10 Hz do 20 kHz 1 V do 10 V CMC 69 · 10⁻⁵ · U + 3,5 mV\nf = 10 Hz do 20 kHz 10 V do 100 V CMC 69 · 10⁻⁵ · U + 35 mV\nf = 10 Hz do 20 kHz 100 V do 750 V CMC 69 · 10⁻⁵ · U + 0,26 V\nf = 20 kHz do 50 kHz 0,2 mV do 100 mV CMC 14 · 10⁻⁴ · U + 58 µV\nf = 20 kHz do 50 kHz 0,1 V do 1 V CMC 14 · 10⁻⁴ · U + 0,58 mV\nf = 20 kHz do 50 kHz 1 V do 10 V CMC 14 · 10⁻⁴ · U + 5,8 mV\nf = 20 kHz do 50 kHz 10 V do 100 V CMC 14 · 10⁻⁴ · U + 58 mV\nf = 20 kHz do 50 kHz 100 V do 750 V CMC 14 · 10⁻⁴ · U + 0,43 V\nf = 50 kHz do 100 kHz 0,2 mV do 100 mV CMC 69· 10⁻⁴ · U + 93 µV\nf = 50 kHz do 100 kHz 0,1 V do 1 V CMC 69 · 10⁻⁴ · U + 0,93 mV\nf = 50 kHz do 100 kHz 1 V do 10 V CMC 69 · 10⁻⁴ · U + 9,3 mV\nf = 50 kHz do 100 kHz 10 V do 33 V CMC 69 · 10⁻⁴ · U + 93 mV\nf = 100 kHz do 300 kHz 0,2 mV do 100 mV CMC 46 · 10⁻³ · U + 0,58 mV\nf = 100 kHz do 300 kHz 0,1 V do 1 V CMC 46 · 10⁻³ · U + 5,8 mV\nf = 100 kHz do 300 kHz 1 V do 10 V CMC 46 · 10⁻³ · U + 58 mV\nf = 100 kHz do 300 kHz 10 V do 33 V CMC 46 · 10⁻³ · U + 0,58 V\nMetoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"P","note":"U – wielkość mierzona (V)","note_en":"U – measured value (V)","search_text":"Kalibratory Wzorcowanie — Napięcie AC\nZakres:\nf = 10 Hz do 20 kHz 0,2 mV do 100 mV CMC 69 · 10⁻⁵ · U + 35 µV\nf = 10 Hz do 20 kHz 0,1 V do 1 V CMC 69 · 10⁻⁵ · U + 0,35 mV\nf = 10 Hz do 20 kHz 1 V do 10 V CMC 69 · 10⁻⁵ · U + 3,5 mV\nf = 10 Hz do 20 kHz 10 V do 100 V CMC 69 · 10⁻⁵ · U + 35 mV\nf = 10 Hz do 20 kHz 100 V do 750 V CMC 69 · 10⁻⁵ · U + 0,26 V\nf = 20 kHz do 50 kHz 0,2 mV do 100 mV CMC 14 · 10⁻⁴ · U + 58 µV\nf = 20 kHz do 50 kHz 0,1 V do 1 V CMC 14 · 10⁻⁴ · U + 0,58 mV\nf = 20 kHz do 50 kHz 1 V do 10 V CMC 14 · 10⁻⁴ · U + 5,8 mV\nf = 20 kHz do 50 kHz 10 V do 100 V CMC 14 · 10⁻⁴ · U + 58 mV\nf = 20 kHz do 50 kHz 100 V do 750 V CMC 14 · 10⁻⁴ · U + 0,43 V\nf = 50 kHz do 100 kHz 0,2 mV do 100 mV CMC 69· 10⁻⁴ · U + 93 µV\nf = 50 kHz do 100 kHz 0,1 V do 1 V CMC 69 · 10⁻⁴ · U + 0,93 mV\nf = 50 kHz do 100 kHz 1 V do 10 V CMC 69 · 10⁻⁴ · U + 9,3 mV\nf = 50 kHz do 100 kHz 10 V do 33 V CMC 69 · 10⁻⁴ · U + 93 mV\nf = 100 kHz do 300 kHz 0,2 mV do 100 mV CMC 46 · 10⁻³ · U + 0,58 mV\nf = 100 kHz do 300 kHz 0,1 V do 1 V CMC 46 · 10⁻³ · U + 5,8 mV\nf = 100 kHz do 300 kHz 1 V do 10 V CMC 46 · 10⁻³ · U + 58 mV\nf = 100 kHz do 300 kHz 10 V do 33 V CMC 46 · 10⁻³ · U + 0,58 V\nMetoda bezpośrednia; Poza stałą lokalizacją (P) EURAMET cg-15 v.3.0 Kalibratory Wzorcowanie — Napiecie AC\nZakres:\nf = 10 Hz do 20 kHz 0,2 mV do 100 mV CMC 69 · 10⁻⁵ · U + 35 µV\nf = 10 Hz do 20 kHz 0,1 V do 1 V CMC 69 · 10⁻⁵ · U + 0,35 mV\nf = 10 Hz do 20 kHz 1 V do 10 V CMC 69 · 10⁻⁵ · U + 3,5 mV\nf = 10 Hz do 20 kHz 10 V do 100 V CMC 69 · 10⁻⁵ · U + 35 mV\nf = 10 Hz do 20 kHz 100 V do 750 V CMC 69 · 10⁻⁵ · U + 0,26 V\nf = 20 kHz do 50 kHz 0,2 mV do 100 mV CMC 14 · 10⁻⁴ · U + 58 µV\nf = 20 kHz do 50 kHz 0,1 V do 1 V CMC 14 · 10⁻⁴ · U + 0,58 mV\nf = 20 kHz do 50 kHz 1 V do 10 V CMC 14 · 10⁻⁴ · U + 5,8 mV\nf = 20 kHz do 50 kHz 10 V do 100 V CMC 14 · 10⁻⁴ · U + 58 mV\nf = 20 kHz do 50 kHz 100 V do 750 V CMC 14 · 10⁻⁴ · U + 0,43 V\nf = 50 kHz do 100 kHz 0,2 mV do 100 mV CMC 69· 10⁻⁴ · U + 93 µV\nf = 50 kHz do 100 kHz 0,1 V do 1 V CMC 69 · 10⁻⁴ · U + 0,93 mV\nf = 50 kHz do 100 kHz 1 V do 10 V CMC 69 · 10⁻⁴ · U + 9,3 mV\nf = 50 kHz do 100 kHz 10 V do 33 V CMC 69 · 10⁻⁴ · U + 93 mV\nf = 100 kHz do 300 kHz 0,2 mV do 100 mV CMC 46 · 10⁻³ · U + 0,58 mV\nf = 100 kHz do 300 kHz 0,1 V do 1 V CMC 46 · 10⁻³ · U + 5,8 mV\nf = 100 kHz do 300 kHz 1 V do 10 V CMC 46 · 10⁻³ · U + 58 mV\nf = 100 kHz do 300 kHz 10 V do 33 V CMC 46 · 10⁻³ · U + 0,58 V\nMetoda bezposrednia; Poza stala lokalizacja (P) EURAMET cg-15 v.3.0","search_en":"Calibrators Calibration — AC voltage Direct method; Outside of permanent location (P) AC voltage Direct method Outside of permanent location (P) f = 10 Hz to 20 kHz f = 10 Hz to 20 kHz f = 10 Hz to 20 kHz f = 10 Hz to 20 kHz f = 10 Hz to 20 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 20 kHz to 50 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 50 kHz to 100 kHz f = 100 kHz to 300 kHz f = 100 kHz to 300 kHz f = 100 kHz to 300 kHz f = 100 kHz to 300 kHz EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"f = 10 Hz bis 20 kHz","range":"0,2 mV to 100 mV","cmc":"69 · 10⁻⁵ · U + 35 µV"},{"name":"f = 10 Hz bis 20 kHz","range":"0,1 V to 1 V","cmc":"69 · 10⁻⁵ · U + 0,35 mV"},{"name":"f = 10 Hz bis 20 kHz","range":"1 V to 10 V","cmc":"69 · 10⁻⁵ · U + 3,5 mV"},{"name":"f = 10 Hz bis 20 kHz","range":"10 V to 100 V","cmc":"69 · 10⁻⁵ · U + 35 mV"},{"name":"f = 10 Hz bis 20 kHz","range":"100 V to 750 V","cmc":"69 · 10⁻⁵ · U + 0,26 V"},{"name":"f = 20 kHz bis 50 kHz","range":"0,2 mV to 100 mV","cmc":"14 · 10⁻⁴ · U + 58 µV"},{"name":"f = 20 kHz bis 50 kHz","range":"0,1 V to 1 V","cmc":"14 · 10⁻⁴ · U + 0,58 mV"},{"name":"f = 20 kHz bis 50 kHz","range":"1 V to 10 V","cmc":"14 · 10⁻⁴ · U + 5,8 mV"},{"name":"f = 20 kHz bis 50 kHz","range":"10 V to 100 V","cmc":"14 · 10⁻⁴ · U + 58 mV"},{"name":"f = 20 kHz bis 50 kHz","range":"100 V to 750 V","cmc":"14 · 10⁻⁴ · U + 0,43 V"},{"name":"f = 50 kHz bis 100 kHz","range":"0,2 mV to 100 mV","cmc":"69· 10⁻⁴ · U + 93 µV"},{"name":"f = 50 kHz bis 100 kHz","range":"0,1 V to 1 V","cmc":"69 · 10⁻⁴ · U + 0,93 mV"},{"name":"f = 50 kHz bis 100 kHz","range":"1 V to 10 V","cmc":"69 · 10⁻⁴ · U + 9,3 mV"},{"name":"f = 50 kHz bis 100 kHz","range":"10 V to 33 V","cmc":"69 · 10⁻⁴ · U + 93 mV"},{"name":"f = 100 kHz bis 300 kHz","range":"0,2 mV to 100 mV","cmc":"46 · 10⁻³ · U + 0,58 mV"},{"name":"f = 100 kHz bis 300 kHz","range":"0,1 V to 1 V","cmc":"46 · 10⁻³ · U + 5,8 mV"},{"name":"f = 100 kHz bis 300 kHz","range":"1 V to 10 V","cmc":"46 · 10⁻³ · U + 58 mV"},{"name":"f = 100 kHz bis 300 kHz","range":"10 V to 33 V","cmc":"46 · 10⁻³ · U + 0,58 V"}],"regulatory_area_de":"AC-Spannung","search_de":"Kalibratoren Kalibrierung — Wechselspannung Direktes Verfahren; Außerhalb des festen Standorts (P) AC-Spannung Direktes Verfahren Außerhalb des festen Standorts (P) f = 10 Hz bis 20 kHz f = 10 Hz bis 20 kHz f = 10 Hz bis 20 kHz f = 10 Hz bis 20 kHz f = 10 Hz bis 20 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 20 kHz bis 50 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 50 kHz bis 100 kHz f = 100 kHz bis 300 kHz f = 100 kHz bis 300 kHz f = 100 kHz bis 300 kHz f = 100 kHz bis 300 kHz EURAMET cg-15 v.3.0","technique_de":"Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Kalibratoren","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"f = 10 Hz 至 20 kHz","range":"0,2 mV to 100 mV","cmc":"69 · 10⁻⁵ · U + 35 µV"},{"name":"f = 10 Hz 至 20 kHz","range":"0,1 V to 1 V","cmc":"69 · 10⁻⁵ · U + 0,35 mV"},{"name":"f = 10 Hz 至 20 kHz","range":"1 V to 10 V","cmc":"69 · 10⁻⁵ · U + 3,5 mV"},{"name":"f = 10 Hz 至 20 kHz","range":"10 V to 100 V","cmc":"69 · 10⁻⁵ · U + 35 mV"},{"name":"f = 10 Hz 至 20 kHz","range":"100 V to 750 V","cmc":"69 · 10⁻⁵ · U + 0,26 V"},{"name":"f = 20 kHz 至 50 kHz","range":"0,2 mV to 100 mV","cmc":"14 · 10⁻⁴ · U + 58 µV"},{"name":"f = 20 kHz 至 50 kHz","range":"0,1 V to 1 V","cmc":"14 · 10⁻⁴ · U + 0,58 mV"},{"name":"f = 20 kHz 至 50 kHz","range":"1 V to 10 V","cmc":"14 · 10⁻⁴ · U + 5,8 mV"},{"name":"f = 20 kHz 至 50 kHz","range":"10 V to 100 V","cmc":"14 · 10⁻⁴ · U + 58 mV"},{"name":"f = 20 kHz 至 50 kHz","range":"100 V to 750 V","cmc":"14 · 10⁻⁴ · U + 0,43 V"},{"name":"f = 50 kHz 至 100 kHz","range":"0,2 mV to 100 mV","cmc":"69· 10⁻⁴ · U + 93 µV"},{"name":"f = 50 kHz 至 100 kHz","range":"0,1 V to 1 V","cmc":"69 · 10⁻⁴ · U + 0,93 mV"},{"name":"f = 50 kHz 至 100 kHz","range":"1 V to 10 V","cmc":"69 · 10⁻⁴ · U + 9,3 mV"},{"name":"f = 50 kHz 至 100 kHz","range":"10 V to 33 V","cmc":"69 · 10⁻⁴ · U + 93 mV"},{"name":"f = 100 kHz 至 300 kHz","range":"0,2 mV to 100 mV","cmc":"46 · 10⁻³ · U + 0,58 mV"},{"name":"f = 100 kHz 至 300 kHz","range":"0,1 V to 1 V","cmc":"46 · 10⁻³ · U + 5,8 mV"},{"name":"f = 100 kHz 至 300 kHz","range":"1 V to 10 V","cmc":"46 · 10⁻³ · U + 58 mV"},{"name":"f = 100 kHz 至 300 kHz","range":"10 V to 33 V","cmc":"46 · 10⁻³ · U + 0,58 V"}],"regulatory_area_zh":"交流电压","search_zh":"校准器 校准 — 交流电压 直接法；固定地点以外 (P) 交流电压 直接法 固定地点以外 (P) f = 10 Hz 至 20 kHz f = 10 Hz 至 20 kHz f = 10 Hz 至 20 kHz f = 10 Hz 至 20 kHz f = 10 Hz 至 20 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 20 kHz 至 50 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 50 kHz 至 100 kHz f = 100 kHz 至 300 kHz f = 100 kHz 至 300 kHz f = 100 kHz 至 300 kHz f = 100 kHz 至 300 kHz EURAMET cg-15 v.3.0","technique_zh":"直接法；固定地点以外 (P)","techniques_zh":["直接法","固定地点以外 (P)"],"test_object_zh":"校准器","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"f = 10 Hz až 20 kHz","range":"0,2 mV to 100 mV","cmc":"69 · 10⁻⁵ · U + 35 µV"},{"name":"f = 10 Hz až 20 kHz","range":"0,1 V to 1 V","cmc":"69 · 10⁻⁵ · U + 0,35 mV"},{"name":"f = 10 Hz až 20 kHz","range":"1 V to 10 V","cmc":"69 · 10⁻⁵ · U + 3,5 mV"},{"name":"f = 10 Hz až 20 kHz","range":"10 V to 100 V","cmc":"69 · 10⁻⁵ · U + 35 mV"},{"name":"f = 10 Hz až 20 kHz","range":"100 V to 750 V","cmc":"69 · 10⁻⁵ · U + 0,26 V"},{"name":"f = 20 kHz až 50 kHz","range":"0,2 mV to 100 mV","cmc":"14 · 10⁻⁴ · U + 58 µV"},{"name":"f = 20 kHz až 50 kHz","range":"0,1 V to 1 V","cmc":"14 · 10⁻⁴ · U + 0,58 mV"},{"name":"f = 20 kHz až 50 kHz","range":"1 V to 10 V","cmc":"14 · 10⁻⁴ · U + 5,8 mV"},{"name":"f = 20 kHz až 50 kHz","range":"10 V to 100 V","cmc":"14 · 10⁻⁴ · U + 58 mV"},{"name":"f = 20 kHz až 50 kHz","range":"100 V to 750 V","cmc":"14 · 10⁻⁴ · U + 0,43 V"},{"name":"f = 50 kHz až 100 kHz","range":"0,2 mV to 100 mV","cmc":"69· 10⁻⁴ · U + 93 µV"},{"name":"f = 50 kHz až 100 kHz","range":"0,1 V to 1 V","cmc":"69 · 10⁻⁴ · U + 0,93 mV"},{"name":"f = 50 kHz až 100 kHz","range":"1 V to 10 V","cmc":"69 · 10⁻⁴ · U + 9,3 mV"},{"name":"f = 50 kHz až 100 kHz","range":"10 V to 33 V","cmc":"69 · 10⁻⁴ · U + 93 mV"},{"name":"f = 100 kHz až 300 kHz","range":"0,2 mV to 100 mV","cmc":"46 · 10⁻³ · U + 0,58 mV"},{"name":"f = 100 kHz až 300 kHz","range":"0,1 V to 1 V","cmc":"46 · 10⁻³ · U + 5,8 mV"},{"name":"f = 100 kHz až 300 kHz","range":"1 V to 10 V","cmc":"46 · 10⁻³ · U + 58 mV"},{"name":"f = 100 kHz až 300 kHz","range":"10 V to 33 V","cmc":"46 · 10⁻³ · U + 0,58 V"}],"regulatory_area_cs":"Napětí AC","search_cs":"Kalibrátory Kalibrace — Napětí AC Přímá metoda; Mimo stálou lokalitu (P) Napětí AC Přímá metoda Mimo stálou lokalitu (P) f = 10 Hz až 20 kHz f = 10 Hz až 20 kHz f = 10 Hz až 20 kHz f = 10 Hz až 20 kHz f = 10 Hz až 20 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 20 kHz až 50 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 50 kHz až 100 kHz f = 100 kHz až 300 kHz f = 100 kHz až 300 kHz f = 100 kHz až 300 kHz f = 100 kHz až 300 kHz EURAMET cg-15 v.3.0","technique_cs":"Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Kalibrátory"},{"_id":"67799d4fbeb5e606cf96d8be","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki prądu analogowe","test_object_en":"Analogue ammeters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"f = 20 Hz do 45 Hz","range":"0,029 mA do 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,12 µA"},{"name":"f = 20 Hz do 45 Hz","range":"0,33 mA do 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 20 Hz do 45 Hz","range":"3,3 mA do 33 mA","cmc":"78 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 20 Hz do 45 Hz","range":"33 mA do 330 mA","cmc":"78 · 10⁻⁵ · I + 23 µA"},{"name":"f = 20 Hz do 45 Hz","range":"0,33 A do 2,2 A","cmc":"15 · 10⁻⁴ · I + 0,24 mA"},{"name":"f = 45 Hz do 65 Hz","range":"0,029 mA do 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 45 Hz do 65 Hz","range":"0,33 mA do 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz do 65 Hz","range":"3,3 mA do 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz do 65 Hz","range":"33 mA do 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz do 65 Hz","range":"0,33 A do 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 45 Hz do 65 Hz","range":"2,2 A do 11 A","cmc":"47 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 65 Hz do 500 Hz","range":"0,029 mA do 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 65 Hz do 500 Hz","range":"0,33 mA do 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 65 Hz do 500 Hz","range":"3,3 mA do 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 65 Hz do 500 Hz","range":"33 mA do 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 65 Hz do 500 Hz","range":"0,33 A do 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 65 Hz do 500 Hz","range":"2,2 A do 11 A","cmc":"76 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 500 Hz do 1 kHz","range":"0,029 mA do 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 500 Hz do 1 kHz","range":"0,33 mA do 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 500 Hz do 1 kHz","range":"3,3 mA do 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 500 Hz do 1 kHz","range":"33 mA do 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 500 Hz do 1 kHz","range":"0,33 A do 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 500 Hz do 1 kHz","range":"2,2 A do 11 A","cmc":"26 · 10⁻⁴ · I + 1,5 mA"},{"name":"f = 1 kHz do 5 kHz","range":"0,029 mA do 0,33 mA","cmc":"30 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 1 kHz do 5 kHz","range":"0,33 mA do 3,3 mA","cmc":"15 · 10⁻⁴ · I + 0,23 µA"},{"name":"f = 1 kHz do 5 kHz","range":"3,3 mA do 33 mA","cmc":"15 · 10⁻⁴ · I + 2,3 µA"},{"name":"f = 1 kHz do 5 kHz","range":"33 mA do 330 mA","cmc":"15 · 10⁻⁴ · I + 23 µA"},{"name":"f = 1 kHz do 5 kHz","range":"0,33 A do 2,2 A","cmc":"58 · 10⁻⁴ · I + 0,29 mA"},{"name":"f = 5 kHz do 10 kHz","range":"0,029 mA do 0,33 mA","cmc":"96 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 5 kHz do 10 kHz","range":"0,33 mA do 3,3 mA","cmc":"47 · 10⁻⁴ · I + 0,44 µA"},{"name":"f = 5 kHz do 10 kHz","range":"3,3 mA do 33 mA","cmc":"48 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 5 kHz do 10 kHz","range":"33 mA do 330 mA","cmc":"48 · 10⁻⁴ · I + 22 µA"}],"parameters_en":[{"name":"f = 20 Hz to 45 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,12 µA"},{"name":"f = 20 Hz to 45 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 20 Hz to 45 Hz","range":"3,3 mA to 33 mA","cmc":"78 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 20 Hz to 45 Hz","range":"33 mA to 330 mA","cmc":"78 · 10⁻⁵ · I + 23 µA"},{"name":"f = 20 Hz to 45 Hz","range":"0,33 A to 2,2 A","cmc":"15 · 10⁻⁴ · I + 0,24 mA"},{"name":"f = 45 Hz to 65 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 45 Hz to 65 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz to 65 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz to 65 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz to 65 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 45 Hz to 65 Hz","range":"2,2 A to 11 A","cmc":"47 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 65 Hz to 500 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 65 Hz to 500 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 65 Hz to 500 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 65 Hz to 500 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 65 Hz to 500 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 65 Hz to 500 Hz","range":"2,2 A to 11 A","cmc":"76 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 500 Hz to 1 kHz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 500 Hz to 1 kHz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 500 Hz to 1 kHz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 500 Hz to 1 kHz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 500 Hz to 1 kHz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 500 Hz to 1 kHz","range":"2,2 A to 11 A","cmc":"26 · 10⁻⁴ · I + 1,5 mA"},{"name":"f = 1 kHz to 5 kHz","range":"0,029 mA to 0,33 mA","cmc":"30 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 1 kHz to 5 kHz","range":"0,33 mA to 3,3 mA","cmc":"15 · 10⁻⁴ · I + 0,23 µA"},{"name":"f = 1 kHz to 5 kHz","range":"3,3 mA to 33 mA","cmc":"15 · 10⁻⁴ · I + 2,3 µA"},{"name":"f = 1 kHz to 5 kHz","range":"33 mA to 330 mA","cmc":"15 · 10⁻⁴ · I + 23 µA"},{"name":"f = 1 kHz to 5 kHz","range":"0,33 A to 2,2 A","cmc":"58 · 10⁻⁴ · I + 0,29 mA"},{"name":"f = 5 kHz to 10 kHz","range":"0,029 mA to 0,33 mA","cmc":"96 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 5 kHz to 10 kHz","range":"0,33 mA to 3,3 mA","cmc":"47 · 10⁻⁴ · I + 0,44 µA"},{"name":"f = 5 kHz to 10 kHz","range":"3,3 mA to 33 mA","cmc":"48 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 5 kHz to 10 kHz","range":"33 mA to 330 mA","cmc":"48 · 10⁻⁴ · I + 22 µA"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\nf = 20 Hz do 45 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,12 µA\nf = 20 Hz do 45 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 20 Hz do 45 Hz 3,3 mA do 33 mA CMC 78 · 10⁻⁵ · I + 2,3 µA\nf = 20 Hz do 45 Hz 33 mA do 330 mA CMC 78 · 10⁻⁵ · I + 23 µA\nf = 20 Hz do 45 Hz 0,33 A do 2,2 A CMC 15 · 10⁻⁴ · I + 0,24 mA\nf = 45 Hz do 65 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 45 Hz do 65 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 45 Hz do 65 Hz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 45 Hz do 65 Hz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 45 Hz do 65 Hz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 45 Hz do 65 Hz 2,2 A do 11 A CMC 47 · 10⁻⁵ · I + 1,6 mA\nf = 65 Hz do 500 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 65 Hz do 500 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 65 Hz do 500 Hz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 65 Hz do 500 Hz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 65 Hz do 500 Hz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 65 Hz do 500 Hz 2,2 A do 11 A CMC 76 · 10⁻⁵ · I + 1,6 mA\nf = 500 Hz do 1 kHz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 500 Hz do 1 kHz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 500 Hz do 1 kHz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 500 Hz do 1 kHz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 500 Hz do 1 kHz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 500 Hz do 1 kHz 2,2 A do 11 A CMC 26 · 10⁻⁴ · I + 1,5 mA\nf = 1 kHz do 5 kHz 0,029 mA do 0,33 mA CMC 30 · 10⁻⁴ · I + 0,12 µA\nf = 1 kHz do 5 kHz 0,33 mA do 3,3 mA CMC 15 · 10⁻⁴ · I + 0,23 µA\nf = 1 kHz do 5 kHz 3,3 mA do 33 mA CMC 15 · 10⁻⁴ · I + 2,3 µA\nf = 1 kHz do 5 kHz 33 mA do 330 mA CMC 15 · 10⁻⁴ · I + 23 µA\nf = 1 kHz do 5 kHz 0,33 A do 2,2 A CMC 58 · 10⁻⁴ · I + 0,29 mA\nf = 5 kHz do 10 kHz 0,029 mA do 0,33 mA CMC 96 · 10⁻⁴ · I + 0,12 µA\nf = 5 kHz do 10 kHz 0,33 mA do 3,3 mA CMC 47 · 10⁻⁴ · I + 0,44 µA\nf = 5 kHz do 10 kHz 3,3 mA do 33 mA CMC 48 · 10⁻⁴ · I + 2,2 µA\nf = 5 kHz do 10 kHz 33 mA do 330 mA CMC 48 · 10⁻⁴ · I + 22 µA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"E /I 1/ MAP","norm_bases":["E /I 1/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Mierniki prądu analogowe Wzorcowanie — Prąd AC\nZakres:\nf = 20 Hz do 45 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,12 µA\nf = 20 Hz do 45 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 20 Hz do 45 Hz 3,3 mA do 33 mA CMC 78 · 10⁻⁵ · I + 2,3 µA\nf = 20 Hz do 45 Hz 33 mA do 330 mA CMC 78 · 10⁻⁵ · I + 23 µA\nf = 20 Hz do 45 Hz 0,33 A do 2,2 A CMC 15 · 10⁻⁴ · I + 0,24 mA\nf = 45 Hz do 65 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 45 Hz do 65 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 45 Hz do 65 Hz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 45 Hz do 65 Hz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 45 Hz do 65 Hz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 45 Hz do 65 Hz 2,2 A do 11 A CMC 47 · 10⁻⁵ · I + 1,6 mA\nf = 65 Hz do 500 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 65 Hz do 500 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 65 Hz do 500 Hz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 65 Hz do 500 Hz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 65 Hz do 500 Hz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 65 Hz do 500 Hz 2,2 A do 11 A CMC 76 · 10⁻⁵ · I + 1,6 mA\nf = 500 Hz do 1 kHz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 500 Hz do 1 kHz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 500 Hz do 1 kHz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 500 Hz do 1 kHz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 500 Hz do 1 kHz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 500 Hz do 1 kHz 2,2 A do 11 A CMC 26 · 10⁻⁴ · I + 1,5 mA\nf = 1 kHz do 5 kHz 0,029 mA do 0,33 mA CMC 30 · 10⁻⁴ · I + 0,12 µA\nf = 1 kHz do 5 kHz 0,33 mA do 3,3 mA CMC 15 · 10⁻⁴ · I + 0,23 µA\nf = 1 kHz do 5 kHz 3,3 mA do 33 mA CMC 15 · 10⁻⁴ · I + 2,3 µA\nf = 1 kHz do 5 kHz 33 mA do 330 mA CMC 15 · 10⁻⁴ · I + 23 µA\nf = 1 kHz do 5 kHz 0,33 A do 2,2 A CMC 58 · 10⁻⁴ · I + 0,29 mA\nf = 5 kHz do 10 kHz 0,029 mA do 0,33 mA CMC 96 · 10⁻⁴ · I + 0,12 µA\nf = 5 kHz do 10 kHz 0,33 mA do 3,3 mA CMC 47 · 10⁻⁴ · I + 0,44 µA\nf = 5 kHz do 10 kHz 3,3 mA do 33 mA CMC 48 · 10⁻⁴ · I + 2,2 µA\nf = 5 kHz do 10 kHz 33 mA do 330 mA CMC 48 · 10⁻⁴ · I + 22 µA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) E /I 1/ MAP Mierniki pradu analogowe Wzorcowanie — Prad AC\nZakres:\nf = 20 Hz do 45 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,12 µA\nf = 20 Hz do 45 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 20 Hz do 45 Hz 3,3 mA do 33 mA CMC 78 · 10⁻⁵ · I + 2,3 µA\nf = 20 Hz do 45 Hz 33 mA do 330 mA CMC 78 · 10⁻⁵ · I + 23 µA\nf = 20 Hz do 45 Hz 0,33 A do 2,2 A CMC 15 · 10⁻⁴ · I + 0,24 mA\nf = 45 Hz do 65 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 45 Hz do 65 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 45 Hz do 65 Hz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 45 Hz do 65 Hz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 45 Hz do 65 Hz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 45 Hz do 65 Hz 2,2 A do 11 A CMC 47 · 10⁻⁵ · I + 1,6 mA\nf = 65 Hz do 500 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 65 Hz do 500 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 65 Hz do 500 Hz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 65 Hz do 500 Hz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 65 Hz do 500 Hz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 65 Hz do 500 Hz 2,2 A do 11 A CMC 76 · 10⁻⁵ · I + 1,6 mA\nf = 500 Hz do 1 kHz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 500 Hz do 1 kHz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 500 Hz do 1 kHz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 500 Hz do 1 kHz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 500 Hz do 1 kHz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 500 Hz do 1 kHz 2,2 A do 11 A CMC 26 · 10⁻⁴ · I + 1,5 mA\nf = 1 kHz do 5 kHz 0,029 mA do 0,33 mA CMC 30 · 10⁻⁴ · I + 0,12 µA\nf = 1 kHz do 5 kHz 0,33 mA do 3,3 mA CMC 15 · 10⁻⁴ · I + 0,23 µA\nf = 1 kHz do 5 kHz 3,3 mA do 33 mA CMC 15 · 10⁻⁴ · I + 2,3 µA\nf = 1 kHz do 5 kHz 33 mA do 330 mA CMC 15 · 10⁻⁴ · I + 23 µA\nf = 1 kHz do 5 kHz 0,33 A do 2,2 A CMC 58 · 10⁻⁴ · I + 0,29 mA\nf = 5 kHz do 10 kHz 0,029 mA do 0,33 mA CMC 96 · 10⁻⁴ · I + 0,12 µA\nf = 5 kHz do 10 kHz 0,33 mA do 3,3 mA CMC 47 · 10⁻⁴ · I + 0,44 µA\nf = 5 kHz do 10 kHz 3,3 mA do 33 mA CMC 48 · 10⁻⁴ · I + 2,2 µA\nf = 5 kHz do 10 kHz 33 mA do 330 mA CMC 48 · 10⁻⁴ · I + 22 µA\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) E /I 1/ MAP","search_en":"Analogue ammeters Calibration — AC current Internal procedure; Direct method; At permanent location (S) AC current Internal procedure Direct method At permanent location (S) f = 20 Hz to 45 Hz f = 20 Hz to 45 Hz f = 20 Hz to 45 Hz f = 20 Hz to 45 Hz f = 20 Hz to 45 Hz f = 45 Hz to 65 Hz f = 45 Hz to 65 Hz f = 45 Hz to 65 Hz f = 45 Hz to 65 Hz f = 45 Hz to 65 Hz f = 45 Hz to 65 Hz f = 65 Hz to 500 Hz f = 65 Hz to 500 Hz f = 65 Hz to 500 Hz f = 65 Hz to 500 Hz f = 65 Hz to 500 Hz f = 65 Hz to 500 Hz f = 500 Hz to 1 kHz f = 500 Hz to 1 kHz f = 500 Hz to 1 kHz f = 500 Hz to 1 kHz f = 500 Hz to 1 kHz f = 500 Hz to 1 kHz f = 1 kHz to 5 kHz f = 1 kHz to 5 kHz f = 1 kHz to 5 kHz f = 1 kHz to 5 kHz f = 1 kHz to 5 kHz f = 5 kHz to 10 kHz f = 5 kHz to 10 kHz f = 5 kHz to 10 kHz f = 5 kHz to 10 kHz E /I 1/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"f = 20 Hz bis 45 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,12 µA"},{"name":"f = 20 Hz bis 45 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 20 Hz bis 45 Hz","range":"3,3 mA to 33 mA","cmc":"78 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 20 Hz bis 45 Hz","range":"33 mA to 330 mA","cmc":"78 · 10⁻⁵ · I + 23 µA"},{"name":"f = 20 Hz bis 45 Hz","range":"0,33 A to 2,2 A","cmc":"15 · 10⁻⁴ · I + 0,24 mA"},{"name":"f = 45 Hz bis 65 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 45 Hz bis 65 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz bis 65 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz bis 65 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz bis 65 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 45 Hz bis 65 Hz","range":"2,2 A to 11 A","cmc":"47 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 65 Hz bis 500 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 65 Hz bis 500 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 65 Hz bis 500 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 65 Hz bis 500 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 65 Hz bis 500 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 65 Hz bis 500 Hz","range":"2,2 A to 11 A","cmc":"76 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 500 Hz bis 1 kHz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 500 Hz bis 1 kHz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 500 Hz bis 1 kHz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 500 Hz bis 1 kHz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 500 Hz bis 1 kHz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 500 Hz bis 1 kHz","range":"2,2 A to 11 A","cmc":"26 · 10⁻⁴ · I + 1,5 mA"},{"name":"f = 1 kHz bis 5 kHz","range":"0,029 mA to 0,33 mA","cmc":"30 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 1 kHz bis 5 kHz","range":"0,33 mA to 3,3 mA","cmc":"15 · 10⁻⁴ · I + 0,23 µA"},{"name":"f = 1 kHz bis 5 kHz","range":"3,3 mA to 33 mA","cmc":"15 · 10⁻⁴ · I + 2,3 µA"},{"name":"f = 1 kHz bis 5 kHz","range":"33 mA to 330 mA","cmc":"15 · 10⁻⁴ · I + 23 µA"},{"name":"f = 1 kHz bis 5 kHz","range":"0,33 A to 2,2 A","cmc":"58 · 10⁻⁴ · I + 0,29 mA"},{"name":"f = 5 kHz bis 10 kHz","range":"0,029 mA to 0,33 mA","cmc":"96 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 5 kHz bis 10 kHz","range":"0,33 mA to 3,3 mA","cmc":"47 · 10⁻⁴ · I + 0,44 µA"},{"name":"f = 5 kHz bis 10 kHz","range":"3,3 mA to 33 mA","cmc":"48 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 5 kHz bis 10 kHz","range":"33 mA to 330 mA","cmc":"48 · 10⁻⁴ · I + 22 µA"}],"regulatory_area_de":"AC-Strom","search_de":"Analoge Strommessgeräte Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) f = 20 Hz bis 45 Hz f = 20 Hz bis 45 Hz f = 20 Hz bis 45 Hz f = 20 Hz bis 45 Hz f = 20 Hz bis 45 Hz f = 45 Hz bis 65 Hz f = 45 Hz bis 65 Hz f = 45 Hz bis 65 Hz f = 45 Hz bis 65 Hz f = 45 Hz bis 65 Hz f = 45 Hz bis 65 Hz f = 65 Hz bis 500 Hz f = 65 Hz bis 500 Hz f = 65 Hz bis 500 Hz f = 65 Hz bis 500 Hz f = 65 Hz bis 500 Hz f = 65 Hz bis 500 Hz f = 500 Hz bis 1 kHz f = 500 Hz bis 1 kHz f = 500 Hz bis 1 kHz f = 500 Hz bis 1 kHz f = 500 Hz bis 1 kHz f = 500 Hz bis 1 kHz f = 1 kHz bis 5 kHz f = 1 kHz bis 5 kHz f = 1 kHz bis 5 kHz f = 1 kHz bis 5 kHz f = 1 kHz bis 5 kHz f = 5 kHz bis 10 kHz f = 5 kHz bis 10 kHz f = 5 kHz bis 10 kHz f = 5 kHz bis 10 kHz E /I 1/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Strommessgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"f = 20 Hz 至 45 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,12 µA"},{"name":"f = 20 Hz 至 45 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 20 Hz 至 45 Hz","range":"3,3 mA to 33 mA","cmc":"78 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 20 Hz 至 45 Hz","range":"33 mA to 330 mA","cmc":"78 · 10⁻⁵ · I + 23 µA"},{"name":"f = 20 Hz 至 45 Hz","range":"0,33 A to 2,2 A","cmc":"15 · 10⁻⁴ · I + 0,24 mA"},{"name":"f = 45 Hz 至 65 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 45 Hz 至 65 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz 至 65 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz 至 65 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz 至 65 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 45 Hz 至 65 Hz","range":"2,2 A to 11 A","cmc":"47 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 65 Hz 至 500 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 65 Hz 至 500 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 65 Hz 至 500 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 65 Hz 至 500 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 65 Hz 至 500 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 65 Hz 至 500 Hz","range":"2,2 A to 11 A","cmc":"76 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 500 Hz 至 1 kHz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 500 Hz 至 1 kHz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 500 Hz 至 1 kHz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 500 Hz 至 1 kHz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 500 Hz 至 1 kHz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 500 Hz 至 1 kHz","range":"2,2 A to 11 A","cmc":"26 · 10⁻⁴ · I + 1,5 mA"},{"name":"f = 1 kHz 至 5 kHz","range":"0,029 mA to 0,33 mA","cmc":"30 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 1 kHz 至 5 kHz","range":"0,33 mA to 3,3 mA","cmc":"15 · 10⁻⁴ · I + 0,23 µA"},{"name":"f = 1 kHz 至 5 kHz","range":"3,3 mA to 33 mA","cmc":"15 · 10⁻⁴ · I + 2,3 µA"},{"name":"f = 1 kHz 至 5 kHz","range":"33 mA to 330 mA","cmc":"15 · 10⁻⁴ · I + 23 µA"},{"name":"f = 1 kHz 至 5 kHz","range":"0,33 A to 2,2 A","cmc":"58 · 10⁻⁴ · I + 0,29 mA"},{"name":"f = 5 kHz 至 10 kHz","range":"0,029 mA to 0,33 mA","cmc":"96 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 5 kHz 至 10 kHz","range":"0,33 mA to 3,3 mA","cmc":"47 · 10⁻⁴ · I + 0,44 µA"},{"name":"f = 5 kHz 至 10 kHz","range":"3,3 mA to 33 mA","cmc":"48 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 5 kHz 至 10 kHz","range":"33 mA to 330 mA","cmc":"48 · 10⁻⁴ · I + 22 µA"}],"regulatory_area_zh":"交流电流","search_zh":"模拟电流表 校准 — 交流电流 内部程序；直接法；在固定地点 (S) 交流电流 内部程序 直接法 在固定地点 (S) f = 20 Hz 至 45 Hz f = 20 Hz 至 45 Hz f = 20 Hz 至 45 Hz f = 20 Hz 至 45 Hz f = 20 Hz 至 45 Hz f = 45 Hz 至 65 Hz f = 45 Hz 至 65 Hz f = 45 Hz 至 65 Hz f = 45 Hz 至 65 Hz f = 45 Hz 至 65 Hz f = 45 Hz 至 65 Hz f = 65 Hz 至 500 Hz f = 65 Hz 至 500 Hz f = 65 Hz 至 500 Hz f = 65 Hz 至 500 Hz f = 65 Hz 至 500 Hz f = 65 Hz 至 500 Hz f = 500 Hz 至 1 kHz f = 500 Hz 至 1 kHz f = 500 Hz 至 1 kHz f = 500 Hz 至 1 kHz f = 500 Hz 至 1 kHz f = 500 Hz 至 1 kHz f = 1 kHz 至 5 kHz f = 1 kHz 至 5 kHz f = 1 kHz 至 5 kHz f = 1 kHz 至 5 kHz f = 1 kHz 至 5 kHz f = 5 kHz 至 10 kHz f = 5 kHz 至 10 kHz f = 5 kHz 至 10 kHz f = 5 kHz 至 10 kHz E /I 1/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"模拟电流表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"f = 20 Hz až 45 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,12 µA"},{"name":"f = 20 Hz až 45 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 20 Hz až 45 Hz","range":"3,3 mA to 33 mA","cmc":"78 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 20 Hz až 45 Hz","range":"33 mA to 330 mA","cmc":"78 · 10⁻⁵ · I + 23 µA"},{"name":"f = 20 Hz až 45 Hz","range":"0,33 A to 2,2 A","cmc":"15 · 10⁻⁴ · I + 0,24 mA"},{"name":"f = 45 Hz až 65 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 45 Hz až 65 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz až 65 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz až 65 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz až 65 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 45 Hz až 65 Hz","range":"2,2 A to 11 A","cmc":"47 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 65 Hz až 500 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 65 Hz až 500 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 65 Hz až 500 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 65 Hz až 500 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 65 Hz až 500 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 65 Hz až 500 Hz","range":"2,2 A to 11 A","cmc":"76 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 500 Hz až 1 kHz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 500 Hz až 1 kHz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 500 Hz až 1 kHz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 500 Hz až 1 kHz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 500 Hz až 1 kHz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 500 Hz až 1 kHz","range":"2,2 A to 11 A","cmc":"26 · 10⁻⁴ · I + 1,5 mA"},{"name":"f = 1 kHz až 5 kHz","range":"0,029 mA to 0,33 mA","cmc":"30 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 1 kHz až 5 kHz","range":"0,33 mA to 3,3 mA","cmc":"15 · 10⁻⁴ · I + 0,23 µA"},{"name":"f = 1 kHz až 5 kHz","range":"3,3 mA to 33 mA","cmc":"15 · 10⁻⁴ · I + 2,3 µA"},{"name":"f = 1 kHz až 5 kHz","range":"33 mA to 330 mA","cmc":"15 · 10⁻⁴ · I + 23 µA"},{"name":"f = 1 kHz až 5 kHz","range":"0,33 A to 2,2 A","cmc":"58 · 10⁻⁴ · I + 0,29 mA"},{"name":"f = 5 kHz až 10 kHz","range":"0,029 mA to 0,33 mA","cmc":"96 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 5 kHz až 10 kHz","range":"0,33 mA to 3,3 mA","cmc":"47 · 10⁻⁴ · I + 0,44 µA"},{"name":"f = 5 kHz až 10 kHz","range":"3,3 mA to 33 mA","cmc":"48 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 5 kHz až 10 kHz","range":"33 mA to 330 mA","cmc":"48 · 10⁻⁴ · I + 22 µA"}],"regulatory_area_cs":"Proud AC","search_cs":"Analogové měřiče proudu Kalibrace — Proud AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) f = 20 Hz až 45 Hz f = 20 Hz až 45 Hz f = 20 Hz až 45 Hz f = 20 Hz až 45 Hz f = 20 Hz až 45 Hz f = 45 Hz až 65 Hz f = 45 Hz až 65 Hz f = 45 Hz až 65 Hz f = 45 Hz až 65 Hz f = 45 Hz až 65 Hz f = 45 Hz až 65 Hz f = 65 Hz až 500 Hz f = 65 Hz až 500 Hz f = 65 Hz až 500 Hz f = 65 Hz až 500 Hz f = 65 Hz až 500 Hz f = 65 Hz až 500 Hz f = 500 Hz až 1 kHz f = 500 Hz až 1 kHz f = 500 Hz až 1 kHz f = 500 Hz až 1 kHz f = 500 Hz až 1 kHz f = 500 Hz až 1 kHz f = 1 kHz až 5 kHz f = 1 kHz až 5 kHz f = 1 kHz až 5 kHz f = 1 kHz až 5 kHz f = 1 kHz až 5 kHz f = 5 kHz až 10 kHz f = 5 kHz až 10 kHz f = 5 kHz až 10 kHz f = 5 kHz až 10 kHz E /I 1/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče proudu"},{"_id":"4fb6d63b90076e5382fc6c32","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki prądu cyfrowe\nMultimetry","test_object_en":"Digital ammeters\nMultimeters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"f = 20 Hz do 45 Hz","range":"0,029 mA do 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,12 µA"},{"name":"f = 20 Hz do 45 Hz","range":"0,33 mA do 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 20 Hz do 45 Hz","range":"3,3 mA do 33 mA","cmc":"78 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 20 Hz do 45 Hz","range":"33 mA do 330 mA","cmc":"78 · 10⁻⁵ · I + 23 µA"},{"name":"f = 20 Hz do 45 Hz","range":"0,33 A do 2,2 A","cmc":"15 · 10⁻⁴ · I + 0,24 mA"},{"name":"f = 45 Hz do 65 Hz","range":"0,029 mA do 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 45 Hz do 65 Hz","range":"0,33 mA do 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz do 65 Hz","range":"3,3 mA do 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz do 65 Hz","range":"33 mA do 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz do 65 Hz","range":"0,33 A do 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 45 Hz do 65 Hz","range":"2,2 A do 11 A","cmc":"47 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 65 Hz do 500 Hz","range":"0,029 mA do 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 65 Hz do 500 Hz","range":"0,33 mA do 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 65 Hz do 500 Hz","range":"3,3 mA do 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 65 Hz do 500 Hz","range":"33 mA do 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 65 Hz do 500 Hz","range":"0,33 A do 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 65 Hz do 500 Hz","range":"2,2 A do 11 A","cmc":"76 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 500 Hz do 1 kHz","range":"0,029 mA do 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 500 Hz do 1 kHz","range":"0,33 mA do 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 500 Hz do 1 kHz","range":"3,3 mA do 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 500 Hz do 1 kHz","range":"33 mA do 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 500 Hz do 1 kHz","range":"0,33 A do 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 500 Hz do 1 kHz","range":"2,2 A do 11 A","cmc":"26 · 10⁻⁴ · I + 1,5 mA"},{"name":"f = 1 kHz do 5 kHz","range":"0,029 mA do 0,33 mA","cmc":"30 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 1 kHz do 5 kHz","range":"0,33 mA do 3,3 mA","cmc":"15 · 10⁻⁴ · I + 0,23 µA"},{"name":"f = 1 kHz do 5 kHz","range":"3,3 mA do 33 mA","cmc":"15 · 10⁻⁴ · I + 2,3 µA"},{"name":"f = 1 kHz do 5 kHz","range":"33 mA do 330 mA","cmc":"15 · 10⁻⁴ · I + 23 µA"},{"name":"f = 1 kHz do 5 kHz","range":"0,33 A do 2,2 A","cmc":"58 · 10⁻⁴ · I + 0,29 mA"},{"name":"f = 5 kHz do 10 kHz","range":"0,029 mA do 0,33 mA","cmc":"96 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 5 kHz do 10 kHz","range":"0,33 mA do 3,3 mA","cmc":"47 · 10⁻⁴ · I + 0,44 µA"},{"name":"f = 5 kHz do 10 kHz","range":"3,3 mA do 33 mA","cmc":"48 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 5 kHz do 10 kHz","range":"33 mA do 330 mA","cmc":"48 · 10⁻⁴ · I + 22 µA"}],"parameters_en":[{"name":"f = 20 Hz to 45 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,12 µA"},{"name":"f = 20 Hz to 45 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 20 Hz to 45 Hz","range":"3,3 mA to 33 mA","cmc":"78 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 20 Hz to 45 Hz","range":"33 mA to 330 mA","cmc":"78 · 10⁻⁵ · I + 23 µA"},{"name":"f = 20 Hz to 45 Hz","range":"0,33 A to 2,2 A","cmc":"15 · 10⁻⁴ · I + 0,24 mA"},{"name":"f = 45 Hz to 65 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 45 Hz to 65 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz to 65 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz to 65 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz to 65 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 45 Hz to 65 Hz","range":"2,2 A to 11 A","cmc":"47 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 65 Hz to 500 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 65 Hz to 500 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 65 Hz to 500 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 65 Hz to 500 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 65 Hz to 500 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 65 Hz to 500 Hz","range":"2,2 A to 11 A","cmc":"76 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 500 Hz to 1 kHz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 500 Hz to 1 kHz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 500 Hz to 1 kHz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 500 Hz to 1 kHz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 500 Hz to 1 kHz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 500 Hz to 1 kHz","range":"2,2 A to 11 A","cmc":"26 · 10⁻⁴ · I + 1,5 mA"},{"name":"f = 1 kHz to 5 kHz","range":"0,029 mA to 0,33 mA","cmc":"30 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 1 kHz to 5 kHz","range":"0,33 mA to 3,3 mA","cmc":"15 · 10⁻⁴ · I + 0,23 µA"},{"name":"f = 1 kHz to 5 kHz","range":"3,3 mA to 33 mA","cmc":"15 · 10⁻⁴ · I + 2,3 µA"},{"name":"f = 1 kHz to 5 kHz","range":"33 mA to 330 mA","cmc":"15 · 10⁻⁴ · I + 23 µA"},{"name":"f = 1 kHz to 5 kHz","range":"0,33 A to 2,2 A","cmc":"58 · 10⁻⁴ · I + 0,29 mA"},{"name":"f = 5 kHz to 10 kHz","range":"0,029 mA to 0,33 mA","cmc":"96 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 5 kHz to 10 kHz","range":"0,33 mA to 3,3 mA","cmc":"47 · 10⁻⁴ · I + 0,44 µA"},{"name":"f = 5 kHz to 10 kHz","range":"3,3 mA to 33 mA","cmc":"48 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 5 kHz to 10 kHz","range":"33 mA to 330 mA","cmc":"48 · 10⁻⁴ · I + 22 µA"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","technique_en":"Direct and indirect method; At permanent location (S)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Direct and indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\nf = 20 Hz do 45 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,12 µA\nf = 20 Hz do 45 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 20 Hz do 45 Hz 3,3 mA do 33 mA CMC 78 · 10⁻⁵ · I + 2,3 µA\nf = 20 Hz do 45 Hz 33 mA do 330 mA CMC 78 · 10⁻⁵ · I + 23 µA\nf = 20 Hz do 45 Hz 0,33 A do 2,2 A CMC 15 · 10⁻⁴ · I + 0,24 mA\nf = 45 Hz do 65 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 45 Hz do 65 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 45 Hz do 65 Hz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 45 Hz do 65 Hz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 45 Hz do 65 Hz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 45 Hz do 65 Hz 2,2 A do 11 A CMC 47 · 10⁻⁵ · I + 1,6 mA\nf = 65 Hz do 500 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 65 Hz do 500 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 65 Hz do 500 Hz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 65 Hz do 500 Hz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 65 Hz do 500 Hz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 65 Hz do 500 Hz 2,2 A do 11 A CMC 76 · 10⁻⁵ · I + 1,6 mA\nf = 500 Hz do 1 kHz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 500 Hz do 1 kHz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 500 Hz do 1 kHz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 500 Hz do 1 kHz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 500 Hz do 1 kHz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 500 Hz do 1 kHz 2,2 A do 11 A CMC 26 · 10⁻⁴ · I + 1,5 mA\nf = 1 kHz do 5 kHz 0,029 mA do 0,33 mA CMC 30 · 10⁻⁴ · I + 0,12 µA\nf = 1 kHz do 5 kHz 0,33 mA do 3,3 mA CMC 15 · 10⁻⁴ · I + 0,23 µA\nf = 1 kHz do 5 kHz 3,3 mA do 33 mA CMC 15 · 10⁻⁴ · I + 2,3 µA\nf = 1 kHz do 5 kHz 33 mA do 330 mA CMC 15 · 10⁻⁴ · I + 23 µA\nf = 1 kHz do 5 kHz 0,33 A do 2,2 A CMC 58 · 10⁻⁴ · I + 0,29 mA\nf = 5 kHz do 10 kHz 0,029 mA do 0,33 mA CMC 96 · 10⁻⁴ · I + 0,12 µA\nf = 5 kHz do 10 kHz 0,33 mA do 3,3 mA CMC 47 · 10⁻⁴ · I + 0,44 µA\nf = 5 kHz do 10 kHz 3,3 mA do 33 mA CMC 48 · 10⁻⁴ · I + 2,2 µA\nf = 5 kHz do 10 kHz 33 mA do 330 mA CMC 48 · 10⁻⁴ · I + 22 µA\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Mierniki prądu cyfrowe\nMultimetry Wzorcowanie — Prąd AC\nZakres:\nf = 20 Hz do 45 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,12 µA\nf = 20 Hz do 45 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 20 Hz do 45 Hz 3,3 mA do 33 mA CMC 78 · 10⁻⁵ · I + 2,3 µA\nf = 20 Hz do 45 Hz 33 mA do 330 mA CMC 78 · 10⁻⁵ · I + 23 µA\nf = 20 Hz do 45 Hz 0,33 A do 2,2 A CMC 15 · 10⁻⁴ · I + 0,24 mA\nf = 45 Hz do 65 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 45 Hz do 65 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 45 Hz do 65 Hz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 45 Hz do 65 Hz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 45 Hz do 65 Hz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 45 Hz do 65 Hz 2,2 A do 11 A CMC 47 · 10⁻⁵ · I + 1,6 mA\nf = 65 Hz do 500 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 65 Hz do 500 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 65 Hz do 500 Hz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 65 Hz do 500 Hz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 65 Hz do 500 Hz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 65 Hz do 500 Hz 2,2 A do 11 A CMC 76 · 10⁻⁵ · I + 1,6 mA\nf = 500 Hz do 1 kHz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 500 Hz do 1 kHz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 500 Hz do 1 kHz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 500 Hz do 1 kHz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 500 Hz do 1 kHz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 500 Hz do 1 kHz 2,2 A do 11 A CMC 26 · 10⁻⁴ · I + 1,5 mA\nf = 1 kHz do 5 kHz 0,029 mA do 0,33 mA CMC 30 · 10⁻⁴ · I + 0,12 µA\nf = 1 kHz do 5 kHz 0,33 mA do 3,3 mA CMC 15 · 10⁻⁴ · I + 0,23 µA\nf = 1 kHz do 5 kHz 3,3 mA do 33 mA CMC 15 · 10⁻⁴ · I + 2,3 µA\nf = 1 kHz do 5 kHz 33 mA do 330 mA CMC 15 · 10⁻⁴ · I + 23 µA\nf = 1 kHz do 5 kHz 0,33 A do 2,2 A CMC 58 · 10⁻⁴ · I + 0,29 mA\nf = 5 kHz do 10 kHz 0,029 mA do 0,33 mA CMC 96 · 10⁻⁴ · I + 0,12 µA\nf = 5 kHz do 10 kHz 0,33 mA do 3,3 mA CMC 47 · 10⁻⁴ · I + 0,44 µA\nf = 5 kHz do 10 kHz 3,3 mA do 33 mA CMC 48 · 10⁻⁴ · I + 2,2 µA\nf = 5 kHz do 10 kHz 33 mA do 330 mA CMC 48 · 10⁻⁴ · I + 22 µA\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) EURAMET cg-15 v.3.0 Mierniki pradu cyfrowe\nMultimetry Wzorcowanie — Prad AC\nZakres:\nf = 20 Hz do 45 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,12 µA\nf = 20 Hz do 45 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 20 Hz do 45 Hz 3,3 mA do 33 mA CMC 78 · 10⁻⁵ · I + 2,3 µA\nf = 20 Hz do 45 Hz 33 mA do 330 mA CMC 78 · 10⁻⁵ · I + 23 µA\nf = 20 Hz do 45 Hz 0,33 A do 2,2 A CMC 15 · 10⁻⁴ · I + 0,24 mA\nf = 45 Hz do 65 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 45 Hz do 65 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 45 Hz do 65 Hz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 45 Hz do 65 Hz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 45 Hz do 65 Hz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 45 Hz do 65 Hz 2,2 A do 11 A CMC 47 · 10⁻⁵ · I + 1,6 mA\nf = 65 Hz do 500 Hz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 65 Hz do 500 Hz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 65 Hz do 500 Hz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 65 Hz do 500 Hz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 65 Hz do 500 Hz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 65 Hz do 500 Hz 2,2 A do 11 A CMC 76 · 10⁻⁵ · I + 1,6 mA\nf = 500 Hz do 1 kHz 0,029 mA do 0,33 mA CMC 97 · 10⁻⁵ · I + 0,19 µA\nf = 500 Hz do 1 kHz 0,33 mA do 3,3 mA CMC 78 · 10⁻⁵ · I + 0,23 µA\nf = 500 Hz do 1 kHz 3,3 mA do 33 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 500 Hz do 1 kHz 33 mA do 330 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 500 Hz do 1 kHz 0,33 A do 2,2 A CMC 75 · 10⁻⁵ · I + 0,24 mA\nf = 500 Hz do 1 kHz 2,2 A do 11 A CMC 26 · 10⁻⁴ · I + 1,5 mA\nf = 1 kHz do 5 kHz 0,029 mA do 0,33 mA CMC 30 · 10⁻⁴ · I + 0,12 µA\nf = 1 kHz do 5 kHz 0,33 mA do 3,3 mA CMC 15 · 10⁻⁴ · I + 0,23 µA\nf = 1 kHz do 5 kHz 3,3 mA do 33 mA CMC 15 · 10⁻⁴ · I + 2,3 µA\nf = 1 kHz do 5 kHz 33 mA do 330 mA CMC 15 · 10⁻⁴ · I + 23 µA\nf = 1 kHz do 5 kHz 0,33 A do 2,2 A CMC 58 · 10⁻⁴ · I + 0,29 mA\nf = 5 kHz do 10 kHz 0,029 mA do 0,33 mA CMC 96 · 10⁻⁴ · I + 0,12 µA\nf = 5 kHz do 10 kHz 0,33 mA do 3,3 mA CMC 47 · 10⁻⁴ · I + 0,44 µA\nf = 5 kHz do 10 kHz 3,3 mA do 33 mA CMC 48 · 10⁻⁴ · I + 2,2 µA\nf = 5 kHz do 10 kHz 33 mA do 330 mA CMC 48 · 10⁻⁴ · I + 22 µA\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) EURAMET cg-15 v.3.0","search_en":"Digital ammeters Multimeters Calibration — AC current Direct and indirect method; At permanent location (S) AC current Direct and indirect method At permanent location (S) f = 20 Hz to 45 Hz f = 20 Hz to 45 Hz f = 20 Hz to 45 Hz f = 20 Hz to 45 Hz f = 20 Hz to 45 Hz f = 45 Hz to 65 Hz f = 45 Hz to 65 Hz f = 45 Hz to 65 Hz f = 45 Hz to 65 Hz f = 45 Hz to 65 Hz f = 45 Hz to 65 Hz f = 65 Hz to 500 Hz f = 65 Hz to 500 Hz f = 65 Hz to 500 Hz f = 65 Hz to 500 Hz f = 65 Hz to 500 Hz f = 65 Hz to 500 Hz f = 500 Hz to 1 kHz f = 500 Hz to 1 kHz f = 500 Hz to 1 kHz f = 500 Hz to 1 kHz f = 500 Hz to 1 kHz f = 500 Hz to 1 kHz f = 1 kHz to 5 kHz f = 1 kHz to 5 kHz f = 1 kHz to 5 kHz f = 1 kHz to 5 kHz f = 1 kHz to 5 kHz f = 5 kHz to 10 kHz f = 5 kHz to 10 kHz f = 5 kHz to 10 kHz f = 5 kHz to 10 kHz EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"f = 20 Hz bis 45 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,12 µA"},{"name":"f = 20 Hz bis 45 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 20 Hz bis 45 Hz","range":"3,3 mA to 33 mA","cmc":"78 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 20 Hz bis 45 Hz","range":"33 mA to 330 mA","cmc":"78 · 10⁻⁵ · I + 23 µA"},{"name":"f = 20 Hz bis 45 Hz","range":"0,33 A to 2,2 A","cmc":"15 · 10⁻⁴ · I + 0,24 mA"},{"name":"f = 45 Hz bis 65 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 45 Hz bis 65 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz bis 65 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz bis 65 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz bis 65 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 45 Hz bis 65 Hz","range":"2,2 A to 11 A","cmc":"47 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 65 Hz bis 500 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 65 Hz bis 500 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 65 Hz bis 500 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 65 Hz bis 500 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 65 Hz bis 500 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 65 Hz bis 500 Hz","range":"2,2 A to 11 A","cmc":"76 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 500 Hz bis 1 kHz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 500 Hz bis 1 kHz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 500 Hz bis 1 kHz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 500 Hz bis 1 kHz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 500 Hz bis 1 kHz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 500 Hz bis 1 kHz","range":"2,2 A to 11 A","cmc":"26 · 10⁻⁴ · I + 1,5 mA"},{"name":"f = 1 kHz bis 5 kHz","range":"0,029 mA to 0,33 mA","cmc":"30 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 1 kHz bis 5 kHz","range":"0,33 mA to 3,3 mA","cmc":"15 · 10⁻⁴ · I + 0,23 µA"},{"name":"f = 1 kHz bis 5 kHz","range":"3,3 mA to 33 mA","cmc":"15 · 10⁻⁴ · I + 2,3 µA"},{"name":"f = 1 kHz bis 5 kHz","range":"33 mA to 330 mA","cmc":"15 · 10⁻⁴ · I + 23 µA"},{"name":"f = 1 kHz bis 5 kHz","range":"0,33 A to 2,2 A","cmc":"58 · 10⁻⁴ · I + 0,29 mA"},{"name":"f = 5 kHz bis 10 kHz","range":"0,029 mA to 0,33 mA","cmc":"96 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 5 kHz bis 10 kHz","range":"0,33 mA to 3,3 mA","cmc":"47 · 10⁻⁴ · I + 0,44 µA"},{"name":"f = 5 kHz bis 10 kHz","range":"3,3 mA to 33 mA","cmc":"48 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 5 kHz bis 10 kHz","range":"33 mA to 330 mA","cmc":"48 · 10⁻⁴ · I + 22 µA"}],"regulatory_area_de":"AC-Strom","search_de":"Digitale Strommessgeräte Multimeter Kalibrierung — Wechselstrom Direktes und indirektes Verfahren; Am festen Standort (S) AC-Strom Direktes und indirektes Verfahren Am festen Standort (S) f = 20 Hz bis 45 Hz f = 20 Hz bis 45 Hz f = 20 Hz bis 45 Hz f = 20 Hz bis 45 Hz f = 20 Hz bis 45 Hz f = 45 Hz bis 65 Hz f = 45 Hz bis 65 Hz f = 45 Hz bis 65 Hz f = 45 Hz bis 65 Hz f = 45 Hz bis 65 Hz f = 45 Hz bis 65 Hz f = 65 Hz bis 500 Hz f = 65 Hz bis 500 Hz f = 65 Hz bis 500 Hz f = 65 Hz bis 500 Hz f = 65 Hz bis 500 Hz f = 65 Hz bis 500 Hz f = 500 Hz bis 1 kHz f = 500 Hz bis 1 kHz f = 500 Hz bis 1 kHz f = 500 Hz bis 1 kHz f = 500 Hz bis 1 kHz f = 500 Hz bis 1 kHz f = 1 kHz bis 5 kHz f = 1 kHz bis 5 kHz f = 1 kHz bis 5 kHz f = 1 kHz bis 5 kHz f = 1 kHz bis 5 kHz f = 5 kHz bis 10 kHz f = 5 kHz bis 10 kHz f = 5 kHz bis 10 kHz f = 5 kHz bis 10 kHz EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Strommessgeräte\nMultimeter","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"f = 20 Hz 至 45 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,12 µA"},{"name":"f = 20 Hz 至 45 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 20 Hz 至 45 Hz","range":"3,3 mA to 33 mA","cmc":"78 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 20 Hz 至 45 Hz","range":"33 mA to 330 mA","cmc":"78 · 10⁻⁵ · I + 23 µA"},{"name":"f = 20 Hz 至 45 Hz","range":"0,33 A to 2,2 A","cmc":"15 · 10⁻⁴ · I + 0,24 mA"},{"name":"f = 45 Hz 至 65 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 45 Hz 至 65 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz 至 65 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz 至 65 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz 至 65 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 45 Hz 至 65 Hz","range":"2,2 A to 11 A","cmc":"47 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 65 Hz 至 500 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 65 Hz 至 500 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 65 Hz 至 500 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 65 Hz 至 500 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 65 Hz 至 500 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 65 Hz 至 500 Hz","range":"2,2 A to 11 A","cmc":"76 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 500 Hz 至 1 kHz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 500 Hz 至 1 kHz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 500 Hz 至 1 kHz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 500 Hz 至 1 kHz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 500 Hz 至 1 kHz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 500 Hz 至 1 kHz","range":"2,2 A to 11 A","cmc":"26 · 10⁻⁴ · I + 1,5 mA"},{"name":"f = 1 kHz 至 5 kHz","range":"0,029 mA to 0,33 mA","cmc":"30 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 1 kHz 至 5 kHz","range":"0,33 mA to 3,3 mA","cmc":"15 · 10⁻⁴ · I + 0,23 µA"},{"name":"f = 1 kHz 至 5 kHz","range":"3,3 mA to 33 mA","cmc":"15 · 10⁻⁴ · I + 2,3 µA"},{"name":"f = 1 kHz 至 5 kHz","range":"33 mA to 330 mA","cmc":"15 · 10⁻⁴ · I + 23 µA"},{"name":"f = 1 kHz 至 5 kHz","range":"0,33 A to 2,2 A","cmc":"58 · 10⁻⁴ · I + 0,29 mA"},{"name":"f = 5 kHz 至 10 kHz","range":"0,029 mA to 0,33 mA","cmc":"96 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 5 kHz 至 10 kHz","range":"0,33 mA to 3,3 mA","cmc":"47 · 10⁻⁴ · I + 0,44 µA"},{"name":"f = 5 kHz 至 10 kHz","range":"3,3 mA to 33 mA","cmc":"48 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 5 kHz 至 10 kHz","range":"33 mA to 330 mA","cmc":"48 · 10⁻⁴ · I + 22 µA"}],"regulatory_area_zh":"交流电流","search_zh":"数字电流表 万用表 校准 — 交流电流 直接法和间接法; 在固定地点 (S) 交流电流 直接法和间接法 在固定地点 (S) f = 20 Hz 至 45 Hz f = 20 Hz 至 45 Hz f = 20 Hz 至 45 Hz f = 20 Hz 至 45 Hz f = 20 Hz 至 45 Hz f = 45 Hz 至 65 Hz f = 45 Hz 至 65 Hz f = 45 Hz 至 65 Hz f = 45 Hz 至 65 Hz f = 45 Hz 至 65 Hz f = 45 Hz 至 65 Hz f = 65 Hz 至 500 Hz f = 65 Hz 至 500 Hz f = 65 Hz 至 500 Hz f = 65 Hz 至 500 Hz f = 65 Hz 至 500 Hz f = 65 Hz 至 500 Hz f = 500 Hz 至 1 kHz f = 500 Hz 至 1 kHz f = 500 Hz 至 1 kHz f = 500 Hz 至 1 kHz f = 500 Hz 至 1 kHz f = 500 Hz 至 1 kHz f = 1 kHz 至 5 kHz f = 1 kHz 至 5 kHz f = 1 kHz 至 5 kHz f = 1 kHz 至 5 kHz f = 1 kHz 至 5 kHz f = 5 kHz 至 10 kHz f = 5 kHz 至 10 kHz f = 5 kHz 至 10 kHz f = 5 kHz 至 10 kHz EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法; 在固定地点 (S)","techniques_zh":["直接法和间接法","在固定地点 (S)"],"test_object_zh":"数字电流表\n万用表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"f = 20 Hz až 45 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,12 µA"},{"name":"f = 20 Hz až 45 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 20 Hz až 45 Hz","range":"3,3 mA to 33 mA","cmc":"78 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 20 Hz až 45 Hz","range":"33 mA to 330 mA","cmc":"78 · 10⁻⁵ · I + 23 µA"},{"name":"f = 20 Hz až 45 Hz","range":"0,33 A to 2,2 A","cmc":"15 · 10⁻⁴ · I + 0,24 mA"},{"name":"f = 45 Hz až 65 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 45 Hz až 65 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz až 65 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz až 65 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz až 65 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 45 Hz až 65 Hz","range":"2,2 A to 11 A","cmc":"47 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 65 Hz až 500 Hz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 65 Hz až 500 Hz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 65 Hz až 500 Hz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 65 Hz až 500 Hz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 65 Hz až 500 Hz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 65 Hz až 500 Hz","range":"2,2 A to 11 A","cmc":"76 · 10⁻⁵ · I + 1,6 mA"},{"name":"f = 500 Hz až 1 kHz","range":"0,029 mA to 0,33 mA","cmc":"97 · 10⁻⁵ · I + 0,19 µA"},{"name":"f = 500 Hz až 1 kHz","range":"0,33 mA to 3,3 mA","cmc":"78 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 500 Hz až 1 kHz","range":"3,3 mA to 33 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 500 Hz až 1 kHz","range":"33 mA to 330 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 500 Hz až 1 kHz","range":"0,33 A to 2,2 A","cmc":"75 · 10⁻⁵ · I + 0,24 mA"},{"name":"f = 500 Hz až 1 kHz","range":"2,2 A to 11 A","cmc":"26 · 10⁻⁴ · I + 1,5 mA"},{"name":"f = 1 kHz až 5 kHz","range":"0,029 mA to 0,33 mA","cmc":"30 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 1 kHz až 5 kHz","range":"0,33 mA to 3,3 mA","cmc":"15 · 10⁻⁴ · I + 0,23 µA"},{"name":"f = 1 kHz až 5 kHz","range":"3,3 mA to 33 mA","cmc":"15 · 10⁻⁴ · I + 2,3 µA"},{"name":"f = 1 kHz až 5 kHz","range":"33 mA to 330 mA","cmc":"15 · 10⁻⁴ · I + 23 µA"},{"name":"f = 1 kHz až 5 kHz","range":"0,33 A to 2,2 A","cmc":"58 · 10⁻⁴ · I + 0,29 mA"},{"name":"f = 5 kHz až 10 kHz","range":"0,029 mA to 0,33 mA","cmc":"96 · 10⁻⁴ · I + 0,12 µA"},{"name":"f = 5 kHz až 10 kHz","range":"0,33 mA to 3,3 mA","cmc":"47 · 10⁻⁴ · I + 0,44 µA"},{"name":"f = 5 kHz až 10 kHz","range":"3,3 mA to 33 mA","cmc":"48 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 5 kHz až 10 kHz","range":"33 mA to 330 mA","cmc":"48 · 10⁻⁴ · I + 22 µA"}],"regulatory_area_cs":"Proud AC","search_cs":"Digitální měřiče proudu Multimetry Kalibrace — Proud AC Přímá a nepřímá metoda; Ve stálé lokalitě (S) Proud AC Přímá a nepřímá metoda Ve stálé lokalitě (S) f = 20 Hz až 45 Hz f = 20 Hz až 45 Hz f = 20 Hz až 45 Hz f = 20 Hz až 45 Hz f = 20 Hz až 45 Hz f = 45 Hz až 65 Hz f = 45 Hz až 65 Hz f = 45 Hz až 65 Hz f = 45 Hz až 65 Hz f = 45 Hz až 65 Hz f = 45 Hz až 65 Hz f = 65 Hz až 500 Hz f = 65 Hz až 500 Hz f = 65 Hz až 500 Hz f = 65 Hz až 500 Hz f = 65 Hz až 500 Hz f = 65 Hz až 500 Hz f = 500 Hz až 1 kHz f = 500 Hz až 1 kHz f = 500 Hz až 1 kHz f = 500 Hz až 1 kHz f = 500 Hz až 1 kHz f = 500 Hz až 1 kHz f = 1 kHz až 5 kHz f = 1 kHz až 5 kHz f = 1 kHz až 5 kHz f = 1 kHz až 5 kHz f = 1 kHz až 5 kHz f = 5 kHz až 10 kHz f = 5 kHz až 10 kHz f = 5 kHz až 10 kHz f = 5 kHz až 10 kHz EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Přímá a nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální měřiče proudu\nMultimetry"},{"_id":"4af98a5dac545567c1c5717c","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"f = 46 Hz do 65 Hz","range":"10 A do 16,5 A","cmc":"23 · 10⁻⁴ · I + 3 mA"},{"name":"f = 46 Hz do 65 Hz","range":"16,5 A do 150 A","cmc":"24 · 10⁻⁴ · I + 22 mA"},{"name":"f = 46 Hz do 65 Hz","range":"150 A do 550 A","cmc":"22 · 10⁻⁴ · I + 90 mA"},{"name":"f = 65 Hz do 440 Hz","range":"10 A do 16,5 A","cmc":"54 · 10⁻⁴ · I + 11 mA"},{"name":"f = 65 Hz do 440 Hz","range":"16,5 A do 150 A","cmc":"65 · 10⁻⁴ · I + 22 mA"},{"name":"f = 65 Hz do 440 Hz","range":"150 A do 550 A","cmc":"62 · 10⁻⁴ · I + 62 mA"}],"parameters_en":[{"name":"f = 46 Hz to 65 Hz","range":"10 A to 16,5 A","cmc":"23 · 10⁻⁴ · I + 3 mA"},{"name":"f = 46 Hz to 65 Hz","range":"16,5 A to 150 A","cmc":"24 · 10⁻⁴ · I + 22 mA"},{"name":"f = 46 Hz to 65 Hz","range":"150 A to 550 A","cmc":"22 · 10⁻⁴ · I + 90 mA"},{"name":"f = 65 Hz to 440 Hz","range":"10 A to 16,5 A","cmc":"54 · 10⁻⁴ · I + 11 mA"},{"name":"f = 65 Hz to 440 Hz","range":"16,5 A to 150 A","cmc":"65 · 10⁻⁴ · I + 22 mA"},{"name":"f = 65 Hz to 440 Hz","range":"150 A to 550 A","cmc":"62 · 10⁻⁴ · I + 62 mA"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\nf = 46 Hz do 65 Hz 10 A do 16,5 A CMC 23 · 10⁻⁴ · I + 3 mA\nf = 46 Hz do 65 Hz 16,5 A do 150 A CMC 24 · 10⁻⁴ · I + 22 mA\nf = 46 Hz do 65 Hz 150 A do 550 A CMC 22 · 10⁻⁴ · I + 90 mA\nf = 65 Hz do 440 Hz 10 A do 16,5 A CMC 54 · 10⁻⁴ · I + 11 mA\nf = 65 Hz do 440 Hz 16,5 A do 150 A CMC 65 · 10⁻⁴ · I + 22 mA\nf = 65 Hz do 440 Hz 150 A do 550 A CMC 62 · 10⁻⁴ · I + 62 mA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"E /I 2/ MAP","norm_bases":["E /I 2/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Mierniki cęgowe Wzorcowanie — Prąd AC\nZakres:\nf = 46 Hz do 65 Hz 10 A do 16,5 A CMC 23 · 10⁻⁴ · I + 3 mA\nf = 46 Hz do 65 Hz 16,5 A do 150 A CMC 24 · 10⁻⁴ · I + 22 mA\nf = 46 Hz do 65 Hz 150 A do 550 A CMC 22 · 10⁻⁴ · I + 90 mA\nf = 65 Hz do 440 Hz 10 A do 16,5 A CMC 54 · 10⁻⁴ · I + 11 mA\nf = 65 Hz do 440 Hz 16,5 A do 150 A CMC 65 · 10⁻⁴ · I + 22 mA\nf = 65 Hz do 440 Hz 150 A do 550 A CMC 62 · 10⁻⁴ · I + 62 mA\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) E /I 2/ MAP Mierniki cegowe Wzorcowanie — Prad AC\nZakres:\nf = 46 Hz do 65 Hz 10 A do 16,5 A CMC 23 · 10⁻⁴ · I + 3 mA\nf = 46 Hz do 65 Hz 16,5 A do 150 A CMC 24 · 10⁻⁴ · I + 22 mA\nf = 46 Hz do 65 Hz 150 A do 550 A CMC 22 · 10⁻⁴ · I + 90 mA\nf = 65 Hz do 440 Hz 10 A do 16,5 A CMC 54 · 10⁻⁴ · I + 11 mA\nf = 65 Hz do 440 Hz 16,5 A do 150 A CMC 65 · 10⁻⁴ · I + 22 mA\nf = 65 Hz do 440 Hz 150 A do 550 A CMC 62 · 10⁻⁴ · I + 62 mA\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) E /I 2/ MAP","search_en":"Clamp meters Calibration — AC current Internal procedure; Direct method; At permanent location (S) AC current Internal procedure Direct method At permanent location (S) f = 46 Hz to 65 Hz f = 46 Hz to 65 Hz f = 46 Hz to 65 Hz f = 65 Hz to 440 Hz f = 65 Hz to 440 Hz f = 65 Hz to 440 Hz E /I 2/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"f = 46 Hz bis 65 Hz","range":"10 A to 16,5 A","cmc":"23 · 10⁻⁴ · I + 3 mA"},{"name":"f = 46 Hz bis 65 Hz","range":"16,5 A to 150 A","cmc":"24 · 10⁻⁴ · I + 22 mA"},{"name":"f = 46 Hz bis 65 Hz","range":"150 A to 550 A","cmc":"22 · 10⁻⁴ · I + 90 mA"},{"name":"f = 65 Hz bis 440 Hz","range":"10 A to 16,5 A","cmc":"54 · 10⁻⁴ · I + 11 mA"},{"name":"f = 65 Hz bis 440 Hz","range":"16,5 A to 150 A","cmc":"65 · 10⁻⁴ · I + 22 mA"},{"name":"f = 65 Hz bis 440 Hz","range":"150 A to 550 A","cmc":"62 · 10⁻⁴ · I + 62 mA"}],"regulatory_area_de":"AC-Strom","search_de":"Zangenmessgeräte Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) f = 46 Hz bis 65 Hz f = 46 Hz bis 65 Hz f = 46 Hz bis 65 Hz f = 65 Hz bis 440 Hz f = 65 Hz bis 440 Hz f = 65 Hz bis 440 Hz E /I 2/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"f = 46 Hz 至 65 Hz","range":"10 A to 16,5 A","cmc":"23 · 10⁻⁴ · I + 3 mA"},{"name":"f = 46 Hz 至 65 Hz","range":"16,5 A to 150 A","cmc":"24 · 10⁻⁴ · I + 22 mA"},{"name":"f = 46 Hz 至 65 Hz","range":"150 A to 550 A","cmc":"22 · 10⁻⁴ · I + 90 mA"},{"name":"f = 65 Hz 至 440 Hz","range":"10 A to 16,5 A","cmc":"54 · 10⁻⁴ · I + 11 mA"},{"name":"f = 65 Hz 至 440 Hz","range":"16,5 A to 150 A","cmc":"65 · 10⁻⁴ · I + 22 mA"},{"name":"f = 65 Hz 至 440 Hz","range":"150 A to 550 A","cmc":"62 · 10⁻⁴ · I + 62 mA"}],"regulatory_area_zh":"交流电流","search_zh":"钳形表 校准 — 交流电流 内部程序；直接法；在固定地点 (S) 交流电流 内部程序 直接法 在固定地点 (S) f = 46 Hz 至 65 Hz f = 46 Hz 至 65 Hz f = 46 Hz 至 65 Hz f = 65 Hz 至 440 Hz f = 65 Hz 至 440 Hz f = 65 Hz 至 440 Hz E /I 2/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"f = 46 Hz až 65 Hz","range":"10 A to 16,5 A","cmc":"23 · 10⁻⁴ · I + 3 mA"},{"name":"f = 46 Hz až 65 Hz","range":"16,5 A to 150 A","cmc":"24 · 10⁻⁴ · I + 22 mA"},{"name":"f = 46 Hz až 65 Hz","range":"150 A to 550 A","cmc":"22 · 10⁻⁴ · I + 90 mA"},{"name":"f = 65 Hz až 440 Hz","range":"10 A to 16,5 A","cmc":"54 · 10⁻⁴ · I + 11 mA"},{"name":"f = 65 Hz až 440 Hz","range":"16,5 A to 150 A","cmc":"65 · 10⁻⁴ · I + 22 mA"},{"name":"f = 65 Hz až 440 Hz","range":"150 A to 550 A","cmc":"62 · 10⁻⁴ · I + 62 mA"}],"regulatory_area_cs":"Proud AC","search_cs":"Klešťové měřiče Kalibrace — Proud AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) f = 46 Hz až 65 Hz f = 46 Hz až 65 Hz f = 46 Hz až 65 Hz f = 65 Hz až 440 Hz f = 65 Hz až 440 Hz f = 65 Hz až 440 Hz E /I 2/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Klešťové měřiče"},{"_id":"f9c4257ba82298edb1c21ca3","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Kalibratory","test_object_en":"Calibrators","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"f = 20 Hz do 45 Hz","range":"0,029 mA do 0,1 mA","cmc":"18 · 10⁻⁴ · I + 34 nA"},{"name":"f = 20 Hz do 45 Hz","range":"0,1 mA do 1 mA","cmc":"18 · 10⁻⁴ · I + 0,22 µA"},{"name":"f = 20 Hz do 45 Hz","range":"1 mA do 10 mA","cmc":"18 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 20 Hz do 45 Hz","range":"10 mA do 100 mA","cmc":"18 · 10⁻⁴ · I + 22 µA"},{"name":"f = 20 Hz do 45 Hz","range":"0,1 A do 1 A","cmc":"19 · 10⁻⁴ · I + 0,23 mA"},{"name":"f = 45 Hz do 100 Hz","range":"0,029 mA do 0,1 mA","cmc":"64 · 10⁻⁵ · I + 36 nA"},{"name":"f = 45 Hz do 100 Hz","range":"0,1 mA do 1 mA","cmc":"69 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz do 100 Hz","range":"1 mA do 10 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz do 100 Hz","range":"10 mA do 100 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz do 100 Hz","range":"0,1 A do 1 A","cmc":"98 · 10⁻⁵ · I + 0,22 mA"},{"name":"f = 100 Hz do 5 kHz","range":"0,029 mA do 0,1 mA","cmc":"64 · 10⁻⁵ · I + 36 nA"},{"name":"f = 100 Hz do 5 kHz","range":"0,1 mA do 1 mA","cmc":"34 · 10⁻⁵ · I + 0,24 µA"},{"name":"f = 100 Hz do 5 kHz","range":"1 mA do 10 mA","cmc":"34 · 10⁻⁵ · I + 2,4 µA"},{"name":"f = 100 Hz do 5 kHz","range":"10 mA do 100 mA","cmc":"34 · 10⁻⁵ · I + 24 µA"},{"name":"f = 100 Hz do 5 kHz","range":"0,1 A do 1 A","cmc":"12 · 10⁻⁴ · I + 0,23 mA"},{"name":"f = 5 kHz do 10 kHz","range":"0,1 mA do 1 mA","cmc":"69 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 5 kHz do 10 kHz","range":"1 mA do 10 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 5 kHz do 10 kHz","range":"10 mA do 100 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 5 kHz do 10 kHz","range":"0,1 A do 1 A","cmc":"35 · 10⁻⁴ · I + 0,23 mA"}],"parameters_en":[{"name":"f = 20 Hz to 45 Hz","range":"0,029 mA to 0,1 mA","cmc":"18 · 10⁻⁴ · I + 34 nA"},{"name":"f = 20 Hz to 45 Hz","range":"0,1 mA to 1 mA","cmc":"18 · 10⁻⁴ · I + 0,22 µA"},{"name":"f = 20 Hz to 45 Hz","range":"1 mA to 10 mA","cmc":"18 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 20 Hz to 45 Hz","range":"10 mA to 100 mA","cmc":"18 · 10⁻⁴ · I + 22 µA"},{"name":"f = 20 Hz to 45 Hz","range":"0,1 A to 1 A","cmc":"19 · 10⁻⁴ · I + 0,23 mA"},{"name":"f = 45 Hz to 100 Hz","range":"0,029 mA to 0,1 mA","cmc":"64 · 10⁻⁵ · I + 36 nA"},{"name":"f = 45 Hz to 100 Hz","range":"0,1 mA to 1 mA","cmc":"69 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz to 100 Hz","range":"1 mA to 10 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz to 100 Hz","range":"10 mA to 100 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz to 100 Hz","range":"0,1 A to 1 A","cmc":"98 · 10⁻⁵ · I + 0,22 mA"},{"name":"f = 100 Hz to 5 kHz","range":"0,029 mA to 0,1 mA","cmc":"64 · 10⁻⁵ · I + 36 nA"},{"name":"f = 100 Hz to 5 kHz","range":"0,1 mA to 1 mA","cmc":"34 · 10⁻⁵ · I + 0,24 µA"},{"name":"f = 100 Hz to 5 kHz","range":"1 mA to 10 mA","cmc":"34 · 10⁻⁵ · I + 2,4 µA"},{"name":"f = 100 Hz to 5 kHz","range":"10 mA to 100 mA","cmc":"34 · 10⁻⁵ · I + 24 µA"},{"name":"f = 100 Hz to 5 kHz","range":"0,1 A to 1 A","cmc":"12 · 10⁻⁴ · I + 0,23 mA"},{"name":"f = 5 kHz to 10 kHz","range":"0,1 mA to 1 mA","cmc":"69 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 5 kHz to 10 kHz","range":"1 mA to 10 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 5 kHz to 10 kHz","range":"10 mA to 100 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 5 kHz to 10 kHz","range":"0,1 A to 1 A","cmc":"35 · 10⁻⁴ · I + 0,23 mA"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","technique_en":"Direct and indirect method; At permanent location (S)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Direct and indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\nf = 20 Hz do 45 Hz 0,029 mA do 0,1 mA CMC 18 · 10⁻⁴ · I + 34 nA\nf = 20 Hz do 45 Hz 0,1 mA do 1 mA CMC 18 · 10⁻⁴ · I + 0,22 µA\nf = 20 Hz do 45 Hz 1 mA do 10 mA CMC 18 · 10⁻⁴ · I + 2,2 µA\nf = 20 Hz do 45 Hz 10 mA do 100 mA CMC 18 · 10⁻⁴ · I + 22 µA\nf = 20 Hz do 45 Hz 0,1 A do 1 A CMC 19 · 10⁻⁴ · I + 0,23 mA\nf = 45 Hz do 100 Hz 0,029 mA do 0,1 mA CMC 64 · 10⁻⁵ · I + 36 nA\nf = 45 Hz do 100 Hz 0,1 mA do 1 mA CMC 69 · 10⁻⁵ · I + 0,23 µA\nf = 45 Hz do 100 Hz 1 mA do 10 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 45 Hz do 100 Hz 10 mA do 100 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 45 Hz do 100 Hz 0,1 A do 1 A CMC 98 · 10⁻⁵ · I + 0,22 mA\nf = 100 Hz do 5 kHz 0,029 mA do 0,1 mA CMC 64 · 10⁻⁵ · I + 36 nA\nf = 100 Hz do 5 kHz 0,1 mA do 1 mA CMC 34 · 10⁻⁵ · I + 0,24 µA\nf = 100 Hz do 5 kHz 1 mA do 10 mA CMC 34 · 10⁻⁵ · I + 2,4 µA\nf = 100 Hz do 5 kHz 10 mA do 100 mA CMC 34 · 10⁻⁵ · I + 24 µA\nf = 100 Hz do 5 kHz 0,1 A do 1 A CMC 12 · 10⁻⁴ · I + 0,23 mA\nf = 5 kHz do 10 kHz 0,1 mA do 1 mA CMC 69 · 10⁻⁵ · I + 0,23 µA\nf = 5 kHz do 10 kHz 1 mA do 10 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 5 kHz do 10 kHz 10 mA do 100 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 5 kHz do 10 kHz 0,1 A do 1 A CMC 35 · 10⁻⁴ · I + 0,23 mA\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Kalibratory Wzorcowanie — Prąd AC\nZakres:\nf = 20 Hz do 45 Hz 0,029 mA do 0,1 mA CMC 18 · 10⁻⁴ · I + 34 nA\nf = 20 Hz do 45 Hz 0,1 mA do 1 mA CMC 18 · 10⁻⁴ · I + 0,22 µA\nf = 20 Hz do 45 Hz 1 mA do 10 mA CMC 18 · 10⁻⁴ · I + 2,2 µA\nf = 20 Hz do 45 Hz 10 mA do 100 mA CMC 18 · 10⁻⁴ · I + 22 µA\nf = 20 Hz do 45 Hz 0,1 A do 1 A CMC 19 · 10⁻⁴ · I + 0,23 mA\nf = 45 Hz do 100 Hz 0,029 mA do 0,1 mA CMC 64 · 10⁻⁵ · I + 36 nA\nf = 45 Hz do 100 Hz 0,1 mA do 1 mA CMC 69 · 10⁻⁵ · I + 0,23 µA\nf = 45 Hz do 100 Hz 1 mA do 10 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 45 Hz do 100 Hz 10 mA do 100 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 45 Hz do 100 Hz 0,1 A do 1 A CMC 98 · 10⁻⁵ · I + 0,22 mA\nf = 100 Hz do 5 kHz 0,029 mA do 0,1 mA CMC 64 · 10⁻⁵ · I + 36 nA\nf = 100 Hz do 5 kHz 0,1 mA do 1 mA CMC 34 · 10⁻⁵ · I + 0,24 µA\nf = 100 Hz do 5 kHz 1 mA do 10 mA CMC 34 · 10⁻⁵ · I + 2,4 µA\nf = 100 Hz do 5 kHz 10 mA do 100 mA CMC 34 · 10⁻⁵ · I + 24 µA\nf = 100 Hz do 5 kHz 0,1 A do 1 A CMC 12 · 10⁻⁴ · I + 0,23 mA\nf = 5 kHz do 10 kHz 0,1 mA do 1 mA CMC 69 · 10⁻⁵ · I + 0,23 µA\nf = 5 kHz do 10 kHz 1 mA do 10 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 5 kHz do 10 kHz 10 mA do 100 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 5 kHz do 10 kHz 0,1 A do 1 A CMC 35 · 10⁻⁴ · I + 0,23 mA\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) EURAMET cg-15 v.3.0 Kalibratory Wzorcowanie — Prad AC\nZakres:\nf = 20 Hz do 45 Hz 0,029 mA do 0,1 mA CMC 18 · 10⁻⁴ · I + 34 nA\nf = 20 Hz do 45 Hz 0,1 mA do 1 mA CMC 18 · 10⁻⁴ · I + 0,22 µA\nf = 20 Hz do 45 Hz 1 mA do 10 mA CMC 18 · 10⁻⁴ · I + 2,2 µA\nf = 20 Hz do 45 Hz 10 mA do 100 mA CMC 18 · 10⁻⁴ · I + 22 µA\nf = 20 Hz do 45 Hz 0,1 A do 1 A CMC 19 · 10⁻⁴ · I + 0,23 mA\nf = 45 Hz do 100 Hz 0,029 mA do 0,1 mA CMC 64 · 10⁻⁵ · I + 36 nA\nf = 45 Hz do 100 Hz 0,1 mA do 1 mA CMC 69 · 10⁻⁵ · I + 0,23 µA\nf = 45 Hz do 100 Hz 1 mA do 10 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 45 Hz do 100 Hz 10 mA do 100 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 45 Hz do 100 Hz 0,1 A do 1 A CMC 98 · 10⁻⁵ · I + 0,22 mA\nf = 100 Hz do 5 kHz 0,029 mA do 0,1 mA CMC 64 · 10⁻⁵ · I + 36 nA\nf = 100 Hz do 5 kHz 0,1 mA do 1 mA CMC 34 · 10⁻⁵ · I + 0,24 µA\nf = 100 Hz do 5 kHz 1 mA do 10 mA CMC 34 · 10⁻⁵ · I + 2,4 µA\nf = 100 Hz do 5 kHz 10 mA do 100 mA CMC 34 · 10⁻⁵ · I + 24 µA\nf = 100 Hz do 5 kHz 0,1 A do 1 A CMC 12 · 10⁻⁴ · I + 0,23 mA\nf = 5 kHz do 10 kHz 0,1 mA do 1 mA CMC 69 · 10⁻⁵ · I + 0,23 µA\nf = 5 kHz do 10 kHz 1 mA do 10 mA CMC 69 · 10⁻⁵ · I + 2,3 µA\nf = 5 kHz do 10 kHz 10 mA do 100 mA CMC 69 · 10⁻⁵ · I + 23 µA\nf = 5 kHz do 10 kHz 0,1 A do 1 A CMC 35 · 10⁻⁴ · I + 0,23 mA\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) EURAMET cg-15 v.3.0","search_en":"Calibrators Calibration — AC current Direct and indirect method; At permanent location (S) AC current Direct and indirect method At permanent location (S) f = 20 Hz to 45 Hz f = 20 Hz to 45 Hz f = 20 Hz to 45 Hz f = 20 Hz to 45 Hz f = 20 Hz to 45 Hz f = 45 Hz to 100 Hz f = 45 Hz to 100 Hz f = 45 Hz to 100 Hz f = 45 Hz to 100 Hz f = 45 Hz to 100 Hz f = 100 Hz to 5 kHz f = 100 Hz to 5 kHz f = 100 Hz to 5 kHz f = 100 Hz to 5 kHz f = 100 Hz to 5 kHz f = 5 kHz to 10 kHz f = 5 kHz to 10 kHz f = 5 kHz to 10 kHz f = 5 kHz to 10 kHz EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"f = 20 Hz bis 45 Hz","range":"0,029 mA to 0,1 mA","cmc":"18 · 10⁻⁴ · I + 34 nA"},{"name":"f = 20 Hz bis 45 Hz","range":"0,1 mA to 1 mA","cmc":"18 · 10⁻⁴ · I + 0,22 µA"},{"name":"f = 20 Hz bis 45 Hz","range":"1 mA to 10 mA","cmc":"18 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 20 Hz bis 45 Hz","range":"10 mA bis 100 mA","cmc":"18 · 10⁻⁴ · I + 22 µA"},{"name":"f = 20 Hz bis 45 Hz","range":"0,1 A to 1 A","cmc":"19 · 10⁻⁴ · I + 0,23 mA"},{"name":"f = 45 Hz bis 100 Hz","range":"0,029 mA to 0,1 mA","cmc":"64 · 10⁻⁵ · I + 36 nA"},{"name":"f = 45 Hz bis 100 Hz","range":"0,1 mA to 1 mA","cmc":"69 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz bis 100 Hz","range":"1 mA to 10 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz bis 100 Hz","range":"10 mA bis 100 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz bis 100 Hz","range":"0,1 A to 1 A","cmc":"98 · 10⁻⁵ · I + 0,22 mA"},{"name":"f = 100 Hz bis 5 kHz","range":"0,029 mA to 0,1 mA","cmc":"64 · 10⁻⁵ · I + 36 nA"},{"name":"f = 100 Hz bis 5 kHz","range":"0,1 mA to 1 mA","cmc":"34 · 10⁻⁵ · I + 0,24 µA"},{"name":"f = 100 Hz bis 5 kHz","range":"1 mA to 10 mA","cmc":"34 · 10⁻⁵ · I + 2,4 µA"},{"name":"f = 100 Hz bis 5 kHz","range":"10 mA bis 100 mA","cmc":"34 · 10⁻⁵ · I + 24 µA"},{"name":"f = 100 Hz bis 5 kHz","range":"0,1 A to 1 A","cmc":"12 · 10⁻⁴ · I + 0,23 mA"},{"name":"f = 5 kHz bis 10 kHz","range":"0,1 mA to 1 mA","cmc":"69 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 5 kHz bis 10 kHz","range":"1 mA to 10 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 5 kHz bis 10 kHz","range":"10 mA bis 100 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 5 kHz bis 10 kHz","range":"0,1 A to 1 A","cmc":"35 · 10⁻⁴ · I + 0,23 mA"}],"regulatory_area_de":"AC-Strom","search_de":"Kalibratoren Kalibrierung — Wechselstrom Direktes und indirektes Verfahren; Am festen Standort (S) AC-Strom Direktes und indirektes Verfahren Am festen Standort (S) f = 20 Hz bis 45 Hz f = 20 Hz bis 45 Hz f = 20 Hz bis 45 Hz f = 20 Hz bis 45 Hz f = 20 Hz bis 45 Hz f = 45 Hz bis 100 Hz f = 45 Hz bis 100 Hz f = 45 Hz bis 100 Hz f = 45 Hz bis 100 Hz f = 45 Hz bis 100 Hz f = 100 Hz bis 5 kHz f = 100 Hz bis 5 kHz f = 100 Hz bis 5 kHz f = 100 Hz bis 5 kHz f = 100 Hz bis 5 kHz f = 5 kHz bis 10 kHz f = 5 kHz bis 10 kHz f = 5 kHz bis 10 kHz f = 5 kHz bis 10 kHz EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"f = 20 Hz 至 45 Hz","range":"0,029 mA to 0,1 mA","cmc":"18 · 10⁻⁴ · I + 34 nA"},{"name":"f = 20 Hz 至 45 Hz","range":"0,1 mA to 1 mA","cmc":"18 · 10⁻⁴ · I + 0,22 µA"},{"name":"f = 20 Hz 至 45 Hz","range":"1 mA to 10 mA","cmc":"18 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 20 Hz 至 45 Hz","range":"10 mA to 100 mA","cmc":"18 · 10⁻⁴ · I + 22 µA"},{"name":"f = 20 Hz 至 45 Hz","range":"0,1 A to 1 A","cmc":"19 · 10⁻⁴ · I + 0,23 mA"},{"name":"f = 45 Hz 至 100 Hz","range":"0,029 mA to 0,1 mA","cmc":"64 · 10⁻⁵ · I + 36 nA"},{"name":"f = 45 Hz 至 100 Hz","range":"0,1 mA to 1 mA","cmc":"69 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz 至 100 Hz","range":"1 mA to 10 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz 至 100 Hz","range":"10 mA to 100 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz 至 100 Hz","range":"0,1 A to 1 A","cmc":"98 · 10⁻⁵ · I + 0,22 mA"},{"name":"f = 100 Hz 至 5 kHz","range":"0,029 mA to 0,1 mA","cmc":"64 · 10⁻⁵ · I + 36 nA"},{"name":"f = 100 Hz 至 5 kHz","range":"0,1 mA to 1 mA","cmc":"34 · 10⁻⁵ · I + 0,24 µA"},{"name":"f = 100 Hz 至 5 kHz","range":"1 mA to 10 mA","cmc":"34 · 10⁻⁵ · I + 2,4 µA"},{"name":"f = 100 Hz 至 5 kHz","range":"10 mA to 100 mA","cmc":"34 · 10⁻⁵ · I + 24 µA"},{"name":"f = 100 Hz 至 5 kHz","range":"0,1 A to 1 A","cmc":"12 · 10⁻⁴ · I + 0,23 mA"},{"name":"f = 5 kHz 至 10 kHz","range":"0,1 mA to 1 mA","cmc":"69 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 5 kHz 至 10 kHz","range":"1 mA to 10 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 5 kHz 至 10 kHz","range":"10 mA to 100 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 5 kHz 至 10 kHz","range":"0,1 A to 1 A","cmc":"35 · 10⁻⁴ · I + 0,23 mA"}],"regulatory_area_zh":"交流电流","search_zh":"校准器 校准 — 交流电流 直接法和间接法; 在固定地点 (S) 交流电流 直接法和间接法 在固定地点 (S) f = 20 Hz 至 45 Hz f = 20 Hz 至 45 Hz f = 20 Hz 至 45 Hz f = 20 Hz 至 45 Hz f = 20 Hz 至 45 Hz f = 45 Hz 至 100 Hz f = 45 Hz 至 100 Hz f = 45 Hz 至 100 Hz f = 45 Hz 至 100 Hz f = 45 Hz 至 100 Hz f = 100 Hz 至 5 kHz f = 100 Hz 至 5 kHz f = 100 Hz 至 5 kHz f = 100 Hz 至 5 kHz f = 100 Hz 至 5 kHz f = 5 kHz 至 10 kHz f = 5 kHz 至 10 kHz f = 5 kHz 至 10 kHz f = 5 kHz 至 10 kHz EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法; 在固定地点 (S)","techniques_zh":["直接法和间接法","在固定地点 (S)"],"test_object_zh":"校准器","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"f = 20 Hz až 45 Hz","range":"0,029 mA to 0,1 mA","cmc":"18 · 10⁻⁴ · I + 34 nA"},{"name":"f = 20 Hz až 45 Hz","range":"0,1 mA to 1 mA","cmc":"18 · 10⁻⁴ · I + 0,22 µA"},{"name":"f = 20 Hz až 45 Hz","range":"1 mA to 10 mA","cmc":"18 · 10⁻⁴ · I + 2,2 µA"},{"name":"f = 20 Hz až 45 Hz","range":"10 mA to 100 mA","cmc":"18 · 10⁻⁴ · I + 22 µA"},{"name":"f = 20 Hz až 45 Hz","range":"0,1 A to 1 A","cmc":"19 · 10⁻⁴ · I + 0,23 mA"},{"name":"f = 45 Hz až 100 Hz","range":"0,029 mA to 0,1 mA","cmc":"64 · 10⁻⁵ · I + 36 nA"},{"name":"f = 45 Hz až 100 Hz","range":"0,1 mA to 1 mA","cmc":"69 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 45 Hz až 100 Hz","range":"1 mA to 10 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 45 Hz až 100 Hz","range":"10 mA to 100 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 45 Hz až 100 Hz","range":"0,1 A to 1 A","cmc":"98 · 10⁻⁵ · I + 0,22 mA"},{"name":"f = 100 Hz až 5 kHz","range":"0,029 mA to 0,1 mA","cmc":"64 · 10⁻⁵ · I + 36 nA"},{"name":"f = 100 Hz až 5 kHz","range":"0,1 mA to 1 mA","cmc":"34 · 10⁻⁵ · I + 0,24 µA"},{"name":"f = 100 Hz až 5 kHz","range":"1 mA to 10 mA","cmc":"34 · 10⁻⁵ · I + 2,4 µA"},{"name":"f = 100 Hz až 5 kHz","range":"10 mA to 100 mA","cmc":"34 · 10⁻⁵ · I + 24 µA"},{"name":"f = 100 Hz až 5 kHz","range":"0,1 A to 1 A","cmc":"12 · 10⁻⁴ · I + 0,23 mA"},{"name":"f = 5 kHz až 10 kHz","range":"0,1 mA to 1 mA","cmc":"69 · 10⁻⁵ · I + 0,23 µA"},{"name":"f = 5 kHz až 10 kHz","range":"1 mA to 10 mA","cmc":"69 · 10⁻⁵ · I + 2,3 µA"},{"name":"f = 5 kHz až 10 kHz","range":"10 mA to 100 mA","cmc":"69 · 10⁻⁵ · I + 23 µA"},{"name":"f = 5 kHz až 10 kHz","range":"0,1 A to 1 A","cmc":"35 · 10⁻⁴ · I + 0,23 mA"}],"regulatory_area_cs":"Proud AC","search_cs":"Kalibrátory Kalibrace — Proud AC Přímá a nepřímá metoda; Ve stálé lokalitě (S) Proud AC Přímá a nepřímá metoda Ve stálé lokalitě (S) f = 20 Hz až 45 Hz f = 20 Hz až 45 Hz f = 20 Hz až 45 Hz f = 20 Hz až 45 Hz f = 20 Hz až 45 Hz f = 45 Hz až 100 Hz f = 45 Hz až 100 Hz f = 45 Hz až 100 Hz f = 45 Hz až 100 Hz f = 45 Hz až 100 Hz f = 100 Hz až 5 kHz f = 100 Hz až 5 kHz f = 100 Hz až 5 kHz f = 100 Hz až 5 kHz f = 100 Hz až 5 kHz f = 5 kHz až 10 kHz f = 5 kHz až 10 kHz f = 5 kHz až 10 kHz f = 5 kHz až 10 kHz EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Přímá a nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory"},{"_id":"f2860b165b40d17a3dafc44e","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Kalibratory","test_object_en":"Calibrators","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"f = 45 Hz do 5 kHz","range":"5 mA do 1 A","cmc":"12 · 10⁻⁴ · I + 0,4 mA"},{"name":"f = 45 Hz do 5 kHz","range":"1 A do 2.2 A","cmc":"95 · 10⁻⁵ · I + 3,2 mA"},{"name":"f = 45 Hz do 5 kHz","range":"2.2 A do 3 A","cmc":"63 · 10⁻⁴ · I + 2,1 mA"}],"parameters_en":[{"name":"f = 45 Hz to 5 kHz","range":"5 mA to 1 A","cmc":"12 · 10⁻⁴ · I + 0,4 mA"},{"name":"f = 45 Hz to 5 kHz","range":"1 A to 2.2 A","cmc":"95 · 10⁻⁵ · I + 3,2 mA"},{"name":"f = 45 Hz to 5 kHz","range":"2.2 A to 3 A","cmc":"63 · 10⁻⁴ · I + 2,1 mA"}],"technique":"Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Direct method; Outside of permanent location (P)","techniques":["Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\nf = 45 Hz do 5 kHz 5 mA do 1 A CMC 12 · 10⁻⁴ · I + 0,4 mA\nf = 45 Hz do 5 kHz 1 A do 2.2 A CMC 95 · 10⁻⁵ · I + 3,2 mA\nf = 45 Hz do 5 kHz 2.2 A do 3 A CMC 63 · 10⁻⁴ · I + 2,1 mA\nMetoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"P","note":"I – wielkość mierzona (A)","note_en":"I – measured value (A)","search_text":"Kalibratory Wzorcowanie — Prąd AC\nZakres:\nf = 45 Hz do 5 kHz 5 mA do 1 A CMC 12 · 10⁻⁴ · I + 0,4 mA\nf = 45 Hz do 5 kHz 1 A do 2.2 A CMC 95 · 10⁻⁵ · I + 3,2 mA\nf = 45 Hz do 5 kHz 2.2 A do 3 A CMC 63 · 10⁻⁴ · I + 2,1 mA\nMetoda bezpośrednia; Poza stałą lokalizacją (P) EURAMET cg-15 v.3.0 Kalibratory Wzorcowanie — Prad AC\nZakres:\nf = 45 Hz do 5 kHz 5 mA do 1 A CMC 12 · 10⁻⁴ · I + 0,4 mA\nf = 45 Hz do 5 kHz 1 A do 2.2 A CMC 95 · 10⁻⁵ · I + 3,2 mA\nf = 45 Hz do 5 kHz 2.2 A do 3 A CMC 63 · 10⁻⁴ · I + 2,1 mA\nMetoda bezposrednia; Poza stala lokalizacja (P) EURAMET cg-15 v.3.0","search_en":"Calibrators Calibration — AC current Direct method; Outside of permanent location (P) AC current Direct method Outside of permanent location (P) f = 45 Hz to 5 kHz f = 45 Hz to 5 kHz f = 45 Hz to 5 kHz EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"f = 45 Hz bis 5 kHz","range":"5 mA to 1 A","cmc":"12 · 10⁻⁴ · I + 0,4 mA"},{"name":"f = 45 Hz bis 5 kHz","range":"1 A to 2.2 A","cmc":"95 · 10⁻⁵ · I + 3,2 mA"},{"name":"f = 45 Hz bis 5 kHz","range":"2.2 A to 3 A","cmc":"63 · 10⁻⁴ · I + 2,1 mA"}],"regulatory_area_de":"AC-Strom","search_de":"Kalibratoren Kalibrierung — Wechselstrom Direktes Verfahren; Außerhalb des festen Standorts (P) AC-Strom Direktes Verfahren Außerhalb des festen Standorts (P) f = 45 Hz bis 5 kHz f = 45 Hz bis 5 kHz f = 45 Hz bis 5 kHz EURAMET cg-15 v.3.0","technique_de":"Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Kalibratoren","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"f = 45 Hz 至 5 kHz","range":"5 mA to 1 A","cmc":"12 · 10⁻⁴ · I + 0,4 mA"},{"name":"f = 45 Hz 至 5 kHz","range":"1 A to 2.2 A","cmc":"95 · 10⁻⁵ · I + 3,2 mA"},{"name":"f = 45 Hz 至 5 kHz","range":"2.2 A to 3 A","cmc":"63 · 10⁻⁴ · I + 2,1 mA"}],"regulatory_area_zh":"交流电流","search_zh":"校准器 校准 — 交流电流 直接法；固定地点以外 (P) 交流电流 直接法 固定地点以外 (P) f = 45 Hz 至 5 kHz f = 45 Hz 至 5 kHz f = 45 Hz 至 5 kHz EURAMET cg-15 v.3.0","technique_zh":"直接法；固定地点以外 (P)","techniques_zh":["直接法","固定地点以外 (P)"],"test_object_zh":"校准器","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"f = 45 Hz až 5 kHz","range":"5 mA to 1 A","cmc":"12 · 10⁻⁴ · I + 0,4 mA"},{"name":"f = 45 Hz až 5 kHz","range":"1 A to 2.2 A","cmc":"95 · 10⁻⁵ · I + 3,2 mA"},{"name":"f = 45 Hz až 5 kHz","range":"2.2 A to 3 A","cmc":"63 · 10⁻⁴ · I + 2,1 mA"}],"regulatory_area_cs":"Proud AC","search_cs":"Kalibrátory Kalibrace — Proud AC Přímá metoda; Mimo stálou lokalitu (P) Proud AC Přímá metoda Mimo stálou lokalitu (P) f = 45 Hz až 5 kHz f = 45 Hz až 5 kHz f = 45 Hz až 5 kHz EURAMET cg-15 v.3.0","technique_cs":"Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Kalibrátory"},{"_id":"0c61e52d609d7cd99cad0c5e","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Rezystory stałe\nRezystory regulowane\nBoczniki","test_object_en":"Fixed resistors\nVariable resistors\nShunts","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"10 µΩ do 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ do 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ do 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ do 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω do 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω do 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ do 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ do 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"parameters_en":[{"name":"","range":"10 µΩ to 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω to 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ to 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct and indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct and indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n10 µΩ do 100 µΩ CMC 32 nΩ\n100 µΩ do 1 mΩ CMC 26· 10⁻⁵ · R + 30 nΩ\n1 mΩ do 10 mΩ CMC 20 · 10⁻⁵ · R\n10 mΩ do 100 mΩ CMC 20 · 10⁻⁶ · R\n0,1 Ω do 1 Ω CMC 5 · 10⁻⁶ · R\n1 Ω do 10 kΩ CMC 1 · 10⁻⁶ · R\n10 kΩ do 100 kΩ CMC 12 · 10⁻⁶ · R + 56 mΩ\n0,1 MΩ do 1 MΩ CMC 18 · 10⁻⁶ · R + 2,2 Ω\n1 MΩ do 10 MΩ CMC 59 · 10⁻⁶ · R + 0,11 kΩ\n10 MΩ do 100 MΩ CMC 58 · 10⁻⁵ · R + 1,2 kΩ\n0,1 GΩ do 1 GΩ CMC 58 · 10⁻⁴ · R + 10 MΩ\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","reference":"E /I 3/ MAP","norm_bases":["E /I 3/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":"R – wielkość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Rezystory stałe\nRezystory regulowane\nBoczniki Wzorcowanie — Rezystancja DC\nZakres:\n10 µΩ do 100 µΩ CMC 32 nΩ\n100 µΩ do 1 mΩ CMC 26· 10⁻⁵ · R + 30 nΩ\n1 mΩ do 10 mΩ CMC 20 · 10⁻⁵ · R\n10 mΩ do 100 mΩ CMC 20 · 10⁻⁶ · R\n0,1 Ω do 1 Ω CMC 5 · 10⁻⁶ · R\n1 Ω do 10 kΩ CMC 1 · 10⁻⁶ · R\n10 kΩ do 100 kΩ CMC 12 · 10⁻⁶ · R + 56 mΩ\n0,1 MΩ do 1 MΩ CMC 18 · 10⁻⁶ · R + 2,2 Ω\n1 MΩ do 10 MΩ CMC 59 · 10⁻⁶ · R + 0,11 kΩ\n10 MΩ do 100 MΩ CMC 58 · 10⁻⁵ · R + 1,2 kΩ\n0,1 GΩ do 1 GΩ CMC 58 · 10⁻⁴ · R + 10 MΩ\nProcedura wewnętrzna; Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) E /I 3/ MAP Rezystory stale\nRezystory regulowane\nBoczniki Wzorcowanie — Rezystancja DC\nZakres:\n10 µΩ do 100 µΩ CMC 32 nΩ\n100 µΩ do 1 mΩ CMC 26· 10⁻⁵ · R + 30 nΩ\n1 mΩ do 10 mΩ CMC 20 · 10⁻⁵ · R\n10 mΩ do 100 mΩ CMC 20 · 10⁻⁶ · R\n0,1 Ω do 1 Ω CMC 5 · 10⁻⁶ · R\n1 Ω do 10 kΩ CMC 1 · 10⁻⁶ · R\n10 kΩ do 100 kΩ CMC 12 · 10⁻⁶ · R + 56 mΩ\n0,1 MΩ do 1 MΩ CMC 18 · 10⁻⁶ · R + 2,2 Ω\n1 MΩ do 10 MΩ CMC 59 · 10⁻⁶ · R + 0,11 kΩ\n10 MΩ do 100 MΩ CMC 58 · 10⁻⁵ · R + 1,2 kΩ\n0,1 GΩ do 1 GΩ CMC 58 · 10⁻⁴ · R + 10 MΩ\nProcedura wewnetrzna; Metoda bezposrednia i posrednia; W stalej lokalizacji (S) E /I 3/ MAP","search_en":"Fixed resistors Variable resistors Shunts Calibration — DC resistance Internal procedure; Direct and indirect method; At permanent location (S) DC resistance Internal procedure Direct and indirect method At permanent location (S) E /I 3/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"10 µΩ to 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω to 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ to 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"regulatory_area_de":"DC-Widerstand","search_de":"Festwiderstände Einstellbare Widerstände Shunts Kalibrierung — DC-Widerstand Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Direktes und indirektes Verfahren Am festen Standort (S) E /I 3/ MAP","technique_de":"Internes Verfahren; Direktes und indirektes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes und indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Festwiderstände\nEinstellbare Widerstände\nShunts","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"10 µΩ to 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω to 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ to 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"regulatory_area_zh":"直流电阻","search_zh":"固定电阻器 可调电阻器 分流器 校准 — 直流电阻 内部程序；直接法和间接法；在固定地点 (S) 直流电阻 内部程序 直接法和间接法 在固定地点 (S) E /I 3/ MAP","technique_zh":"内部程序；直接法和间接法；在固定地点 (S)","techniques_zh":["内部程序","直接法和间接法","在固定地点 (S)"],"test_object_zh":"固定电阻器\n可调电阻器\n分流器","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"10 µΩ to 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω to 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ to 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"regulatory_area_cs":"Odpor DC","search_cs":"Pevné rezistory Nastavitelné rezistory Bočníky Kalibrace — Odpor DC Vnitřní postup; Přímá a nepřímá metoda; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Přímá a nepřímá metoda Ve stálé lokalitě (S) E /I 3/ MAP","technique_cs":"Vnitřní postup; Přímá a nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá a nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Pevné rezistory\nNastavitelné rezistory\nBočníky"},{"_id":"29ed554ceab13f9ff604702c","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki rezystancji cyfrowe\nMultimetry\nKalibratory","test_object_en":"Digital ohmmeters\nMultimeters\nCalibrators","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"10 µΩ do 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ do 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ do 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ do 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω do 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω do 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ do 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ do 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"parameters_en":[{"name":"","range":"10 µΩ to 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω to 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ to 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","technique_en":"Direct and indirect method; At permanent location (S)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Direct and indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n10 µΩ do 100 µΩ CMC 32 nΩ\n100 µΩ do 1 mΩ CMC 26· 10⁻⁵ · R + 30 nΩ\n1 mΩ do 10 mΩ CMC 20 · 10⁻⁵ · R\n10 mΩ do 100 mΩ CMC 20 · 10⁻⁶ · R\n0,1 Ω do 1 Ω CMC 5 · 10⁻⁶ · R\n1 Ω do 10 kΩ CMC 1 · 10⁻⁶ · R\n10 kΩ do 100 kΩ CMC 12 · 10⁻⁶ · R + 56 mΩ\n0,1 MΩ do 1 MΩ CMC 18 · 10⁻⁶ · R + 2,2 Ω\n1 MΩ do 10 MΩ CMC 59 · 10⁻⁶ · R + 0,11 kΩ\n10 MΩ do 100 MΩ CMC 58 · 10⁻⁵ · R + 1,2 kΩ\n0,1 GΩ do 1 GΩ CMC 58 · 10⁻⁴ · R + 10 MΩ\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":"R – wielkość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Mierniki rezystancji cyfrowe\nMultimetry\nKalibratory Wzorcowanie — Rezystancja DC\nZakres:\n10 µΩ do 100 µΩ CMC 32 nΩ\n100 µΩ do 1 mΩ CMC 26· 10⁻⁵ · R + 30 nΩ\n1 mΩ do 10 mΩ CMC 20 · 10⁻⁵ · R\n10 mΩ do 100 mΩ CMC 20 · 10⁻⁶ · R\n0,1 Ω do 1 Ω CMC 5 · 10⁻⁶ · R\n1 Ω do 10 kΩ CMC 1 · 10⁻⁶ · R\n10 kΩ do 100 kΩ CMC 12 · 10⁻⁶ · R + 56 mΩ\n0,1 MΩ do 1 MΩ CMC 18 · 10⁻⁶ · R + 2,2 Ω\n1 MΩ do 10 MΩ CMC 59 · 10⁻⁶ · R + 0,11 kΩ\n10 MΩ do 100 MΩ CMC 58 · 10⁻⁵ · R + 1,2 kΩ\n0,1 GΩ do 1 GΩ CMC 58 · 10⁻⁴ · R + 10 MΩ\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) EURAMET cg-15 v.3.0 Mierniki rezystancji cyfrowe\nMultimetry\nKalibratory Wzorcowanie — Rezystancja DC\nZakres:\n10 µΩ do 100 µΩ CMC 32 nΩ\n100 µΩ do 1 mΩ CMC 26· 10⁻⁵ · R + 30 nΩ\n1 mΩ do 10 mΩ CMC 20 · 10⁻⁵ · R\n10 mΩ do 100 mΩ CMC 20 · 10⁻⁶ · R\n0,1 Ω do 1 Ω CMC 5 · 10⁻⁶ · R\n1 Ω do 10 kΩ CMC 1 · 10⁻⁶ · R\n10 kΩ do 100 kΩ CMC 12 · 10⁻⁶ · R + 56 mΩ\n0,1 MΩ do 1 MΩ CMC 18 · 10⁻⁶ · R + 2,2 Ω\n1 MΩ do 10 MΩ CMC 59 · 10⁻⁶ · R + 0,11 kΩ\n10 MΩ do 100 MΩ CMC 58 · 10⁻⁵ · R + 1,2 kΩ\n0,1 GΩ do 1 GΩ CMC 58 · 10⁻⁴ · R + 10 MΩ\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) EURAMET cg-15 v.3.0","search_en":"Digital ohmmeters Multimeters Calibrators Calibration — DC resistance Direct and indirect method; At permanent location (S) DC resistance Direct and indirect method At permanent location (S) EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":19,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"10 µΩ to 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω to 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ to 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"regulatory_area_de":"DC-Widerstand","search_de":"Digitale Widerstandsmessgeräte Multimeter Kalibratoren Kalibrierung — DC-Widerstand Direktes und indirektes Verfahren; Am festen Standort (S) DC-Widerstand Direktes und indirektes Verfahren Am festen Standort (S) EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Widerstandsmessgeräte\nMultimeter\nKalibratoren","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"10 µΩ to 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω to 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ to 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"regulatory_area_zh":"直流电阻","search_zh":"数字电阻测量仪 万用表 校准器 校准 — 直流电阻 直接法和间接法; 在固定地点 (S) 直流电阻 直接法和间接法 在固定地点 (S) EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法; 在固定地点 (S)","techniques_zh":["直接法和间接法","在固定地点 (S)"],"test_object_zh":"数字电阻测量仪\n万用表\n校准器","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"10 µΩ to 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω to 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ to 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"regulatory_area_cs":"Odpor DC","search_cs":"Digitální měřiče odporu Multimetry Kalibrátory Kalibrace — Odpor DC Přímá a nepřímá metoda; Ve stálé lokalitě (S) Odpor DC Přímá a nepřímá metoda Ve stálé lokalitě (S) EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Přímá a nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální měřiče odporu\nMultimetry\nKalibrátory"},{"_id":"89465883d4574bc1a8881c4e","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki rezystancji analogowe","test_object_en":"Analogue ohmmeters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"10 µΩ do 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ do 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ do 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ do 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω do 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω do 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ do 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ do 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"parameters_en":[{"name":"","range":"10 µΩ to 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω to 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ to 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n10 µΩ do 100 µΩ CMC 32 nΩ\n100 µΩ do 1 mΩ CMC 26· 10⁻⁵ · R + 30 nΩ\n1 mΩ do 10 mΩ CMC 20 · 10⁻⁵ · R\n10 mΩ do 100 mΩ CMC 20 · 10⁻⁶ · R\n0,1 Ω do 1 Ω CMC 5 · 10⁻⁶ · R\n1 Ω do 10 kΩ CMC 1 · 10⁻⁶ · R\n10 kΩ do 100 kΩ CMC 12 · 10⁻⁶ · R + 56 mΩ\n0,1 MΩ do 1 MΩ CMC 18 · 10⁻⁶ · R + 2,2 Ω\n1 MΩ do 10 MΩ CMC 59 · 10⁻⁶ · R + 0,11 kΩ\n10 MΩ do 100 MΩ CMC 58 · 10⁻⁵ · R + 1,2 kΩ\n0,1 GΩ do 1 GΩ CMC 58 · 10⁻⁴ · R + 10 MΩ\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"E /I 1/ MAP","norm_bases":["E /I 1/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":"R – wielkość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Mierniki rezystancji analogowe Wzorcowanie — Rezystancja DC\nZakres:\n10 µΩ do 100 µΩ CMC 32 nΩ\n100 µΩ do 1 mΩ CMC 26· 10⁻⁵ · R + 30 nΩ\n1 mΩ do 10 mΩ CMC 20 · 10⁻⁵ · R\n10 mΩ do 100 mΩ CMC 20 · 10⁻⁶ · R\n0,1 Ω do 1 Ω CMC 5 · 10⁻⁶ · R\n1 Ω do 10 kΩ CMC 1 · 10⁻⁶ · R\n10 kΩ do 100 kΩ CMC 12 · 10⁻⁶ · R + 56 mΩ\n0,1 MΩ do 1 MΩ CMC 18 · 10⁻⁶ · R + 2,2 Ω\n1 MΩ do 10 MΩ CMC 59 · 10⁻⁶ · R + 0,11 kΩ\n10 MΩ do 100 MΩ CMC 58 · 10⁻⁵ · R + 1,2 kΩ\n0,1 GΩ do 1 GΩ CMC 58 · 10⁻⁴ · R + 10 MΩ\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) E /I 1/ MAP Mierniki rezystancji analogowe Wzorcowanie — Rezystancja DC\nZakres:\n10 µΩ do 100 µΩ CMC 32 nΩ\n100 µΩ do 1 mΩ CMC 26· 10⁻⁵ · R + 30 nΩ\n1 mΩ do 10 mΩ CMC 20 · 10⁻⁵ · R\n10 mΩ do 100 mΩ CMC 20 · 10⁻⁶ · R\n0,1 Ω do 1 Ω CMC 5 · 10⁻⁶ · R\n1 Ω do 10 kΩ CMC 1 · 10⁻⁶ · R\n10 kΩ do 100 kΩ CMC 12 · 10⁻⁶ · R + 56 mΩ\n0,1 MΩ do 1 MΩ CMC 18 · 10⁻⁶ · R + 2,2 Ω\n1 MΩ do 10 MΩ CMC 59 · 10⁻⁶ · R + 0,11 kΩ\n10 MΩ do 100 MΩ CMC 58 · 10⁻⁵ · R + 1,2 kΩ\n0,1 GΩ do 1 GΩ CMC 58 · 10⁻⁴ · R + 10 MΩ\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) E /I 1/ MAP","search_en":"Analogue ohmmeters Calibration — DC resistance Internal procedure; Direct method; At permanent location (S) DC resistance Internal procedure Direct method At permanent location (S) E /I 1/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":20,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"10 µΩ to 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω to 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ to 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"regulatory_area_de":"DC-Widerstand","search_de":"Analoge Widerstandsmessgeräte Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Direktes Verfahren Am festen Standort (S) E /I 1/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Widerstandsmessgeräte","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"10 µΩ to 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω to 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ to 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"regulatory_area_zh":"直流电阻","search_zh":"模拟式电阻表 校准 — 直流电阻 内部程序；直接法；在固定地点 (S) 直流电阻 内部程序 直接法 在固定地点 (S) E /I 1/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"模拟式电阻表","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"10 µΩ to 100 µΩ","cmc":"32 nΩ"},{"name":"","range":"100 µΩ to 1 mΩ","cmc":"26· 10⁻⁵ · R + 30 nΩ"},{"name":"","range":"1 mΩ to 10 mΩ","cmc":"20 · 10⁻⁵ · R"},{"name":"","range":"10 mΩ to 100 mΩ","cmc":"20 · 10⁻⁶ · R"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"5 · 10⁻⁶ · R"},{"name":"","range":"1 Ω to 10 kΩ","cmc":"1 · 10⁻⁶ · R"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"12 · 10⁻⁶ · R + 56 mΩ"},{"name":"","range":"0,1 MΩ to 1 MΩ","cmc":"18 · 10⁻⁶ · R + 2,2 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"59 · 10⁻⁶ · R + 0,11 kΩ"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"58 · 10⁻⁵ · R + 1,2 kΩ"},{"name":"","range":"0,1 GΩ to 1 GΩ","cmc":"58 · 10⁻⁴ · R + 10 MΩ"}],"regulatory_area_cs":"Odpor DC","search_cs":"Analogové měřiče odporu Kalibrace — Odpor DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) E /I 1/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče odporu"},{"_id":"923809d3372fe2a4decaf3f0","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Rezystory stałe\nRezystory regulowane","test_object_en":"Fixed resistors\nVariable resistors","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"1 mΩ do 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω do 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω do 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ do 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"parameters_en":[{"name":"","range":"1 mΩ to 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n1 mΩ do 10 Ω CMC 70 · 10⁻⁶ · R + 0,1 mΩ\n10 Ω do 100 Ω CMC 60 · 10⁻⁶ · R + 1,0 mΩ\n100 Ω do 1 kΩ CMC 58 · 10⁻⁶ · R + 2,3 mΩ\n1 kΩ do 10 kΩ CMC 58 · 10⁻⁶ · R + 23 mΩ\n10 kΩ do 100 kΩ CMC 80 · 10⁻⁶ · R + 0,47 Ω\n100 kΩ do 1 MΩ CMC 80 · 10⁻⁶ · R + 5,0 Ω\n1 MΩ do 10 MΩ CMC 46 · 10⁻⁵ · R + 48 Ω\n10 MΩ do 100 MΩ CMC 17 · 10⁻⁴ · R + 0,61 kΩ\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"E /I 3/ MAP\nP4 / MAP","norm_bases":["E /I 3/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"P","note":"R – wielkość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Rezystory stałe\nRezystory regulowane Wzorcowanie — Rezystancja DC\nZakres:\n1 mΩ do 10 Ω CMC 70 · 10⁻⁶ · R + 0,1 mΩ\n10 Ω do 100 Ω CMC 60 · 10⁻⁶ · R + 1,0 mΩ\n100 Ω do 1 kΩ CMC 58 · 10⁻⁶ · R + 2,3 mΩ\n1 kΩ do 10 kΩ CMC 58 · 10⁻⁶ · R + 23 mΩ\n10 kΩ do 100 kΩ CMC 80 · 10⁻⁶ · R + 0,47 Ω\n100 kΩ do 1 MΩ CMC 80 · 10⁻⁶ · R + 5,0 Ω\n1 MΩ do 10 MΩ CMC 46 · 10⁻⁵ · R + 48 Ω\n10 MΩ do 100 MΩ CMC 17 · 10⁻⁴ · R + 0,61 kΩ\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) E /I 3/ MAP\nP4 / MAP Rezystory stale\nRezystory regulowane Wzorcowanie — Rezystancja DC\nZakres:\n1 mΩ do 10 Ω CMC 70 · 10⁻⁶ · R + 0,1 mΩ\n10 Ω do 100 Ω CMC 60 · 10⁻⁶ · R + 1,0 mΩ\n100 Ω do 1 kΩ CMC 58 · 10⁻⁶ · R + 2,3 mΩ\n1 kΩ do 10 kΩ CMC 58 · 10⁻⁶ · R + 23 mΩ\n10 kΩ do 100 kΩ CMC 80 · 10⁻⁶ · R + 0,47 Ω\n100 kΩ do 1 MΩ CMC 80 · 10⁻⁶ · R + 5,0 Ω\n1 MΩ do 10 MΩ CMC 46 · 10⁻⁵ · R + 48 Ω\n10 MΩ do 100 MΩ CMC 17 · 10⁻⁴ · R + 0,61 kΩ\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) E /I 3/ MAP\nP4 / MAP","search_en":"Fixed resistors Variable resistors Calibration — DC resistance Internal procedure; Direct method; Outside of permanent location (P) DC resistance Internal procedure Direct method Outside of permanent location (P) E /I 3/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":21,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"1 mΩ to 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"regulatory_area_de":"DC-Widerstand","search_de":"Festwiderstände Einstellbare Widerstände Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) DC-Widerstand Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) E /I 3/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Festwiderstände\nEinstellbare Widerstände","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"1 mΩ to 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"regulatory_area_zh":"直流电阻","search_zh":"固定电阻器 可调电阻器 校准 — 直流电阻 内部程序；直接法；固定地点以外 (P) 直流电阻 内部程序 直接法 固定地点以外 (P) E /I 3/ MAP P4 / MAP","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"固定电阻器\n可调电阻器","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"1 mΩ to 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"regulatory_area_cs":"Odpor DC","search_cs":"Pevné rezistory Nastavitelné rezistory Kalibrace — Odpor DC Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Odpor DC Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) E /I 3/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Pevné rezistory\nNastavitelné rezistory"},{"_id":"893aac8b9d5df34d110f7dd5","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Kalibratory\nMierniki rezystancji cyfrowe\nMultimetry","test_object_en":"Calibrators\nDigital ohmmeters\nMultimeters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"1 mΩ do 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω do 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω do 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ do 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"parameters_en":[{"name":"","range":"1 mΩ to 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"technique":"Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Direct method; Outside of permanent location (P)","techniques":["Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n1 mΩ do 10 Ω CMC 70 · 10⁻⁶ · R + 0,1 mΩ\n10 Ω do 100 Ω CMC 60 · 10⁻⁶ · R + 1,0 mΩ\n100 Ω do 1 kΩ CMC 58 · 10⁻⁶ · R + 2,3 mΩ\n1 kΩ do 10 kΩ CMC 58 · 10⁻⁶ · R + 23 mΩ\n10 kΩ do 100 kΩ CMC 80 · 10⁻⁶ · R + 0,47 Ω\n100 kΩ do 1 MΩ CMC 80 · 10⁻⁶ · R + 5,0 Ω\n1 MΩ do 10 MΩ CMC 46 · 10⁻⁵ · R + 48 Ω\n10 MΩ do 100 MΩ CMC 17 · 10⁻⁴ · R + 0,61 kΩ\nMetoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"P","note":"R – wielkość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Kalibratory\nMierniki rezystancji cyfrowe\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n1 mΩ do 10 Ω CMC 70 · 10⁻⁶ · R + 0,1 mΩ\n10 Ω do 100 Ω CMC 60 · 10⁻⁶ · R + 1,0 mΩ\n100 Ω do 1 kΩ CMC 58 · 10⁻⁶ · R + 2,3 mΩ\n1 kΩ do 10 kΩ CMC 58 · 10⁻⁶ · R + 23 mΩ\n10 kΩ do 100 kΩ CMC 80 · 10⁻⁶ · R + 0,47 Ω\n100 kΩ do 1 MΩ CMC 80 · 10⁻⁶ · R + 5,0 Ω\n1 MΩ do 10 MΩ CMC 46 · 10⁻⁵ · R + 48 Ω\n10 MΩ do 100 MΩ CMC 17 · 10⁻⁴ · R + 0,61 kΩ\nMetoda bezpośrednia; Poza stałą lokalizacją (P) EURAMET cg-15 v.3.0 Kalibratory\nMierniki rezystancji cyfrowe\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n1 mΩ do 10 Ω CMC 70 · 10⁻⁶ · R + 0,1 mΩ\n10 Ω do 100 Ω CMC 60 · 10⁻⁶ · R + 1,0 mΩ\n100 Ω do 1 kΩ CMC 58 · 10⁻⁶ · R + 2,3 mΩ\n1 kΩ do 10 kΩ CMC 58 · 10⁻⁶ · R + 23 mΩ\n10 kΩ do 100 kΩ CMC 80 · 10⁻⁶ · R + 0,47 Ω\n100 kΩ do 1 MΩ CMC 80 · 10⁻⁶ · R + 5,0 Ω\n1 MΩ do 10 MΩ CMC 46 · 10⁻⁵ · R + 48 Ω\n10 MΩ do 100 MΩ CMC 17 · 10⁻⁴ · R + 0,61 kΩ\nMetoda bezposrednia; Poza stala lokalizacja (P) EURAMET cg-15 v.3.0","search_en":"Calibrators Digital ohmmeters Multimeters Calibration — DC resistance Direct method; Outside of permanent location (P) DC resistance Direct method Outside of permanent location (P) EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":22,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"1 mΩ to 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"regulatory_area_de":"DC-Widerstand","search_de":"Kalibratoren Digitale Widerstandsmessgeräte Multimeter Kalibrierung — DC-Widerstand Direktes Verfahren; Außerhalb des festen Standorts (P) DC-Widerstand Direktes Verfahren Außerhalb des festen Standorts (P) EURAMET cg-15 v.3.0","technique_de":"Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Kalibratoren\nDigitale Widerstandsmessgeräte\nMultimeter","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"1 mΩ to 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"regulatory_area_zh":"直流电阻","search_zh":"校准器 数字电阻测量仪 万用表 校准 — 直流电阻 直接法；固定地点以外 (P) 直流电阻 直接法 固定地点以外 (P) EURAMET cg-15 v.3.0","technique_zh":"直接法；固定地点以外 (P)","techniques_zh":["直接法","固定地点以外 (P)"],"test_object_zh":"校准器\n数字电阻测量仪\n万用表","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"1 mΩ to 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"regulatory_area_cs":"Odpor DC","search_cs":"Kalibrátory Digitální měřiče odporu Multimetry Kalibrace — Odpor DC Přímá metoda; Mimo stálou lokalitu (P) Odpor DC Přímá metoda Mimo stálou lokalitu (P) EURAMET cg-15 v.3.0","technique_cs":"Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Kalibrátory\nDigitální měřiče odporu\nMultimetry"},{"_id":"d39408a0bd55b77c0f2a4280","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki rezystancji analogowe","test_object_en":"Analogue ohmmeters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"1 mΩ do 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω do 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω do 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ do 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"parameters_en":[{"name":"","range":"1 mΩ to 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n1 mΩ do 10 Ω CMC 70 · 10⁻⁶ · R + 0,1 mΩ\n10 Ω do 100 Ω CMC 60 · 10⁻⁶ · R + 1,0 mΩ\n100 Ω do 1 kΩ CMC 58 · 10⁻⁶ · R + 2,3 mΩ\n1 kΩ do 10 kΩ CMC 58 · 10⁻⁶ · R + 23 mΩ\n10 kΩ do 100 kΩ CMC 80 · 10⁻⁶ · R + 0,47 Ω\n100 kΩ do 1 MΩ CMC 80 · 10⁻⁶ · R + 5,0 Ω\n1 MΩ do 10 MΩ CMC 46 · 10⁻⁵ · R + 48 Ω\n10 MΩ do 100 MΩ CMC 17 · 10⁻⁴ · R + 0,61 kΩ\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"E /I 1/ MAP\nP4 / MAP","norm_bases":["E /I 1/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"P","note":"R – wielkość mierzona (Ω)","note_en":"R – measured value (Ω)","search_text":"Mierniki rezystancji analogowe Wzorcowanie — Rezystancja DC\nZakres:\n1 mΩ do 10 Ω CMC 70 · 10⁻⁶ · R + 0,1 mΩ\n10 Ω do 100 Ω CMC 60 · 10⁻⁶ · R + 1,0 mΩ\n100 Ω do 1 kΩ CMC 58 · 10⁻⁶ · R + 2,3 mΩ\n1 kΩ do 10 kΩ CMC 58 · 10⁻⁶ · R + 23 mΩ\n10 kΩ do 100 kΩ CMC 80 · 10⁻⁶ · R + 0,47 Ω\n100 kΩ do 1 MΩ CMC 80 · 10⁻⁶ · R + 5,0 Ω\n1 MΩ do 10 MΩ CMC 46 · 10⁻⁵ · R + 48 Ω\n10 MΩ do 100 MΩ CMC 17 · 10⁻⁴ · R + 0,61 kΩ\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) E /I 1/ MAP\nP4 / MAP Mierniki rezystancji analogowe Wzorcowanie — Rezystancja DC\nZakres:\n1 mΩ do 10 Ω CMC 70 · 10⁻⁶ · R + 0,1 mΩ\n10 Ω do 100 Ω CMC 60 · 10⁻⁶ · R + 1,0 mΩ\n100 Ω do 1 kΩ CMC 58 · 10⁻⁶ · R + 2,3 mΩ\n1 kΩ do 10 kΩ CMC 58 · 10⁻⁶ · R + 23 mΩ\n10 kΩ do 100 kΩ CMC 80 · 10⁻⁶ · R + 0,47 Ω\n100 kΩ do 1 MΩ CMC 80 · 10⁻⁶ · R + 5,0 Ω\n1 MΩ do 10 MΩ CMC 46 · 10⁻⁵ · R + 48 Ω\n10 MΩ do 100 MΩ CMC 17 · 10⁻⁴ · R + 0,61 kΩ\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) E /I 1/ MAP\nP4 / MAP","search_en":"Analogue ohmmeters Calibration — DC resistance Internal procedure; Direct method; Outside of permanent location (P) DC resistance Internal procedure Direct method Outside of permanent location (P) E /I 1/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":23,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"1 mΩ to 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"regulatory_area_de":"DC-Widerstand","search_de":"Analoge Widerstandsmessgeräte Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) DC-Widerstand Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) E /I 1/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Analoge Widerstandsmessgeräte","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"1 mΩ to 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"regulatory_area_zh":"直流电阻","search_zh":"模拟式电阻表 校准 — 直流电阻 内部程序；直接法；固定地点以外 (P) 直流电阻 内部程序 直接法 固定地点以外 (P) E /I 1/ MAP P4 / MAP","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"模拟式电阻表","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"1 mΩ to 10 Ω","cmc":"70 · 10⁻⁶ · R + 0,1 mΩ"},{"name":"","range":"10 Ω to 100 Ω","cmc":"60 · 10⁻⁶ · R + 1,0 mΩ"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"58 · 10⁻⁶ · R + 2,3 mΩ"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"58 · 10⁻⁶ · R + 23 mΩ"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"80 · 10⁻⁶ · R + 0,47 Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"80 · 10⁻⁶ · R + 5,0 Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"46 · 10⁻⁵ · R + 48 Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"17 · 10⁻⁴ · R + 0,61 kΩ"}],"regulatory_area_cs":"Odpor DC","search_cs":"Analogové měřiče odporu Kalibrace — Odpor DC Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Odpor DC Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) E /I 1/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Analogové měřiče odporu"},{"_id":"5f3f8bad3398a3d23a5064a6","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki mocy czynnej cyfrowe","test_object_en":"Digital active power meters","methodology":"Wzorcowanie — Moc DC","methodology_en":"Calibration — DC power","parameters":[{"name":"0,33 V do 1000 V, 3,3 mA do 9 mA","range":"3 W do 9 W","cmc":"0,046 · 10⁻² · w"},{"name":"0,33 V do 1000 V, 9 mA do 33 mA","range":"3 W do 33 W","cmc":"0,034 · 10⁻² · w"},{"name":"0,33 V do 1000 V, 33 mA do 90 mA","range":"3 W do 90 W","cmc":"0,047 · 10⁻² · w"},{"name":"0,33 V do 1000 V, 90 mA do 330 mA","range":"3 W do 330 W","cmc":"0,034 · 10⁻² · w"},{"name":"0,33 V do 1000 V, 0,33 A do 0,9 A","range":"3 W do 900 W","cmc":"0,092 · 10⁻² · w"},{"name":"0,33 V do 1000 V, 0,9 A do 2,2 A","range":"3 W do 2.2 kW","cmc":"0,069 · 10⁻² · w"},{"name":"0,33 V do 1000 V, 2,2 A do 4,5 A","range":"3 W do 4,5 kW","cmc":"0,14 · 10⁻² · w"},{"name":"0,33 V do 1000 V, 4,5 A do 11 A","range":"3 W do 11 kW","cmc":"0,10 · 10⁻² · w"}],"parameters_en":[{"name":"0,33 V to 1000 V, 3,3 mA to 9 mA","range":"3 W to 9 W","cmc":"0,046 · 10⁻² · w"},{"name":"0,33 V to 1000 V, 9 mA to 33 mA","range":"3 W to 33 W","cmc":"0,034 · 10⁻² · w"},{"name":"0,33 V to 1000 V, 33 mA to 90 mA","range":"3 W to 90 W","cmc":"0,047 · 10⁻² · w"},{"name":"0,33 V to 1000 V, 90 mA to 330 mA","range":"3 W to 330 W","cmc":"0,034 · 10⁻² · w"},{"name":"0,33 V to 1000 V, 0,33 A to 0,9 A","range":"3 W to 900 W","cmc":"0,092 · 10⁻² · w"},{"name":"0,33 V to 1000 V, 0,9 A to 2,2 A","range":"3 W to 2.2 kW","cmc":"0,069 · 10⁻² · w"},{"name":"0,33 V to 1000 V, 2,2 A to 4,5 A","range":"3 W to 4,5 kW","cmc":"0,14 · 10⁻² · w"},{"name":"0,33 V to 1000 V, 4,5 A to 11 A","range":"3 W to 11 kW","cmc":"0,10 · 10⁻² · w"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moc DC\nZakres:\n0,33 V do 1000 V, 3,3 mA do 9 mA 3 W do 9 W CMC 0,046 · 10⁻² · w\n0,33 V do 1000 V, 9 mA do 33 mA 3 W do 33 W CMC 0,034 · 10⁻² · w\n0,33 V do 1000 V, 33 mA do 90 mA 3 W do 90 W CMC 0,047 · 10⁻² · w\n0,33 V do 1000 V, 90 mA do 330 mA 3 W do 330 W CMC 0,034 · 10⁻² · w\n0,33 V do 1000 V, 0,33 A do 0,9 A 3 W do 900 W CMC 0,092 · 10⁻² · w\n0,33 V do 1000 V, 0,9 A do 2,2 A 3 W do 2.2 kW CMC 0,069 · 10⁻² · w\n0,33 V do 1000 V, 2,2 A do 4,5 A 3 W do 4,5 kW CMC 0,14 · 10⁻² · w\n0,33 V do 1000 V, 4,5 A do 11 A 3 W do 11 kW CMC 0,10 · 10⁻² · w\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"E /I 2/ MAP","norm_bases":["E /I 2/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moc DC","regulatory_area_en":"DC power","outside_premises":false,"location_of_activity":"S","note":"w – wielkość mierzona (W)","note_en":"w – measured value (W)","search_text":"Mierniki mocy czynnej cyfrowe Wzorcowanie — Moc DC\nZakres:\n0,33 V do 1000 V, 3,3 mA do 9 mA 3 W do 9 W CMC 0,046 · 10⁻² · w\n0,33 V do 1000 V, 9 mA do 33 mA 3 W do 33 W CMC 0,034 · 10⁻² · w\n0,33 V do 1000 V, 33 mA do 90 mA 3 W do 90 W CMC 0,047 · 10⁻² · w\n0,33 V do 1000 V, 90 mA do 330 mA 3 W do 330 W CMC 0,034 · 10⁻² · w\n0,33 V do 1000 V, 0,33 A do 0,9 A 3 W do 900 W CMC 0,092 · 10⁻² · w\n0,33 V do 1000 V, 0,9 A do 2,2 A 3 W do 2.2 kW CMC 0,069 · 10⁻² · w\n0,33 V do 1000 V, 2,2 A do 4,5 A 3 W do 4,5 kW CMC 0,14 · 10⁻² · w\n0,33 V do 1000 V, 4,5 A do 11 A 3 W do 11 kW CMC 0,10 · 10⁻² · w\nProcedura wewnętrzna; W stałej lokalizacji (S) E /I 2/ MAP Mierniki mocy czynnej cyfrowe Wzorcowanie — Moc DC\nZakres:\n0,33 V do 1000 V, 3,3 mA do 9 mA 3 W do 9 W CMC 0,046 · 10⁻² · w\n0,33 V do 1000 V, 9 mA do 33 mA 3 W do 33 W CMC 0,034 · 10⁻² · w\n0,33 V do 1000 V, 33 mA do 90 mA 3 W do 90 W CMC 0,047 · 10⁻² · w\n0,33 V do 1000 V, 90 mA do 330 mA 3 W do 330 W CMC 0,034 · 10⁻² · w\n0,33 V do 1000 V, 0,33 A do 0,9 A 3 W do 900 W CMC 0,092 · 10⁻² · w\n0,33 V do 1000 V, 0,9 A do 2,2 A 3 W do 2.2 kW CMC 0,069 · 10⁻² · w\n0,33 V do 1000 V, 2,2 A do 4,5 A 3 W do 4,5 kW CMC 0,14 · 10⁻² · w\n0,33 V do 1000 V, 4,5 A do 11 A 3 W do 11 kW CMC 0,10 · 10⁻² · w\nProcedura wewnetrzna; W stalej lokalizacji (S) E /I 2/ MAP","search_en":"Digital active power meters Calibration — DC power Internal procedure; At permanent location (S) DC power Internal procedure At permanent location (S) 0,33 V to 1000 V, 3,3 mA to 9 mA 0,33 V to 1000 V, 9 mA to 33 mA 0,33 V to 1000 V, 33 mA to 90 mA 0,33 V to 1000 V, 90 mA to 330 mA 0,33 V to 1000 V, 0,33 A to 0,9 A 0,33 V to 1000 V, 0,9 A to 2,2 A 0,33 V to 1000 V, 2,2 A to 4,5 A 0,33 V to 1000 V, 4,5 A to 11 A E /I 2/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":24,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Leistung","parameters_de":[{"name":"0,33 V bis 1000 V, 3,3 mA bis 9 mA","range":"3 W to 9 W","cmc":"0,046 · 10⁻² · w"},{"name":"0,33 V bis 1000 V, 9 mA bis 33 mA","range":"3 W to 33 W","cmc":"0,034 · 10⁻² · w"},{"name":"0,33 V bis 1000 V, 33 mA bis 90 mA","range":"3 W to 90 W","cmc":"0,047 · 10⁻² · w"},{"name":"0,33 V bis 1000 V, 90 mA bis 330 mA","range":"3 W to 330 W","cmc":"0,034 · 10⁻² · w"},{"name":"0,33 V bis 1000 V, 0,33 A bis 0,9 A","range":"3 W to 900 W","cmc":"0,092 · 10⁻² · w"},{"name":"0,33 V bis 1000 V, 0,9 A bis 2,2 A","range":"3 W to 2.2 kW","cmc":"0,069 · 10⁻² · w"},{"name":"0,33 V bis 1000 V, 2,2 A bis 4,5 A","range":"3 W to 4,5 kW","cmc":"0,14 · 10⁻² · w"},{"name":"0,33 V bis 1000 V, 4,5 A bis 11 A","range":"3 W to 11 kW","cmc":"0,10 · 10⁻² · w"}],"regulatory_area_de":"DC-Leistung","search_de":"Digitale Wirkleistungsmesser Kalibrierung — DC-Leistung Internes Verfahren; Am festen Standort (S) DC-Leistung Internes Verfahren Am festen Standort (S) 0,33 V bis 1000 V, 3,3 mA bis 9 mA 0,33 V bis 1000 V, 9 mA bis 33 mA 0,33 V bis 1000 V, 33 mA bis 90 mA 0,33 V bis 1000 V, 90 mA bis 330 mA 0,33 V bis 1000 V, 0,33 A bis 0,9 A 0,33 V bis 1000 V, 0,9 A bis 2,2 A 0,33 V bis 1000 V, 2,2 A bis 4,5 A 0,33 V bis 1000 V, 4,5 A bis 11 A E /I 2/ MAP","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Digitale Wirkleistungsmesser","methodology_zh":"校准 — 直流功率","parameters_zh":[{"name":"0,33 V 至 1000 V, 3,3 mA 至 9 mA","range":"3 W to 9 W","cmc":"0,046 · 10⁻² · w"},{"name":"0,33 V 至 1000 V, 9 mA 至 33 mA","range":"3 W to 33 W","cmc":"0,034 · 10⁻² · w"},{"name":"0,33 V 至 1000 V, 33 mA 至 90 mA","range":"3 W to 90 W","cmc":"0,047 · 10⁻² · w"},{"name":"0,33 V 至 1000 V, 90 mA 至 330 mA","range":"3 W to 330 W","cmc":"0,034 · 10⁻² · w"},{"name":"0,33 V 至 1000 V, 0,33 A 至 0,9 A","range":"3 W to 900 W","cmc":"0,092 · 10⁻² · w"},{"name":"0,33 V 至 1000 V, 0,9 A 至 2,2 A","range":"3 W to 2.2 kW","cmc":"0,069 · 10⁻² · w"},{"name":"0,33 V 至 1000 V, 2,2 A 至 4,5 A","range":"3 W to 4,5 kW","cmc":"0,14 · 10⁻² · w"},{"name":"0,33 V 至 1000 V, 4,5 A 至 11 A","range":"3 W to 11 kW","cmc":"0,10 · 10⁻² · w"}],"regulatory_area_zh":"直流功率","search_zh":"数字有功功率计 校准 — 直流功率 内部程序；在固定地点 (S) 直流功率 内部程序 在固定地点 (S) 0,33 V 至 1000 V, 3,3 mA 至 9 mA 0,33 V 至 1000 V, 9 mA 至 33 mA 0,33 V 至 1000 V, 33 mA 至 90 mA 0,33 V 至 1000 V, 90 mA 至 330 mA 0,33 V 至 1000 V, 0,33 A 至 0,9 A 0,33 V 至 1000 V, 0,9 A 至 2,2 A 0,33 V 至 1000 V, 2,2 A 至 4,5 A 0,33 V 至 1000 V, 4,5 A 至 11 A E /I 2/ MAP","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"数字有功功率计","methodology_cs":"Kalibrace — Stejnosměrný výkon","parameters_cs":[{"name":"0,33 V až 1000 V, 3,3 mA až 9 mA","range":"3 W to 9 W","cmc":"0,046 · 10⁻² · w"},{"name":"0,33 V až 1000 V, 9 mA až 33 mA","range":"3 W to 33 W","cmc":"0,034 · 10⁻² · w"},{"name":"0,33 V až 1000 V, 33 mA až 90 mA","range":"3 W to 90 W","cmc":"0,047 · 10⁻² · w"},{"name":"0,33 V až 1000 V, 90 mA až 330 mA","range":"3 W to 330 W","cmc":"0,034 · 10⁻² · w"},{"name":"0,33 V až 1000 V, 0,33 A až 0,9 A","range":"3 W to 900 W","cmc":"0,092 · 10⁻² · w"},{"name":"0,33 V až 1000 V, 0,9 A až 2,2 A","range":"3 W to 2.2 kW","cmc":"0,069 · 10⁻² · w"},{"name":"0,33 V až 1000 V, 2,2 A až 4,5 A","range":"3 W to 4,5 kW","cmc":"0,14 · 10⁻² · w"},{"name":"0,33 V až 1000 V, 4,5 A až 11 A","range":"3 W to 11 kW","cmc":"0,10 · 10⁻² · w"}],"regulatory_area_cs":"Stejnosměrný výkon","search_cs":"Digitální měřiče činného výkonu Kalibrace — Stejnosměrný výkon Vnitřní postup; Ve stálé lokalitě (S) Stejnosměrný výkon Vnitřní postup Ve stálé lokalitě (S) 0,33 V až 1000 V, 3,3 mA až 9 mA 0,33 V až 1000 V, 9 mA až 33 mA 0,33 V až 1000 V, 33 mA až 90 mA 0,33 V až 1000 V, 90 mA až 330 mA 0,33 V až 1000 V, 0,33 A až 0,9 A 0,33 V až 1000 V, 0,9 A až 2,2 A 0,33 V až 1000 V, 2,2 A až 4,5 A 0,33 V až 1000 V, 4,5 A až 11 A E /I 2/ MAP","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální měřiče činného výkonu"},{"_id":"4758e54e67426d3d7c864974","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki mocy czynnej cyfrowe\njednofazowe","test_object_en":"Digital active power meters\nsingle-phase","methodology":"Wzorcowanie — Moc AC","methodology_en":"Calibration — AC power","parameters":[{"name":"f = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 3,3 mA do 9 mA","range":"3 W do 9 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 9 mA do 33 mA","range":"3 W do 33 W","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 33 mA do 90 mA","range":"3 W do 90 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 90 mA do 330 mA","range":"3 W do 330 W","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 0,33 A do 0,9 A","range":"3 W do 900 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 0,9 A do 2,2 A","range":"3 W do 2.2 kW","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 2,2 A do 4,5 A","range":"3 W do 4,5 kW","cmc":"0,23 · 10⁻² · w"},{"name":"f = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 4,5 A do 11 A","range":"3 W do 11 kW","cmc":"0,17 · 10⁻² · w"}],"parameters_en":[{"name":"f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 3,3 mA to 9 mA","range":"3 W to 9 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 9 mA to 33 mA","range":"3 W to 33 W","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 33 mA to 90 mA","range":"3 W to 90 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 90 mA to 330 mA","range":"3 W to 330 W","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 0,33 A to 0,9 A","range":"3 W to 900 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 0,9 A to 2,2 A","range":"3 W to 2.2 kW","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 2,2 A to 4,5 A","range":"3 W to 4,5 kW","cmc":"0,23 · 10⁻² · w"},{"name":"f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 4,5 A to 11 A","range":"3 W to 11 kW","cmc":"0,17 · 10⁻² · w"}],"technique":"Procedura wewnętrzna; PF = 1; W stałej lokalizacji (S)","technique_en":"Internal procedure; PF = 1; At permanent location (S)","techniques":["Procedura wewnętrzna","PF = 1","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","PF = 1","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moc AC\nZakres:\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 3,3 mA do 9 mA 3 W do 9 W CMC 0,29 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 9 mA do 33 mA 3 W do 33 W CMC 0,17 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 33 mA do 90 mA 3 W do 90 W CMC 0,29 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 90 mA do 330 mA 3 W do 330 W CMC 0,17 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 0,33 A do 0,9 A 3 W do 900 W CMC 0,29 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 0,9 A do 2,2 A 3 W do 2.2 kW CMC 0,17 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 2,2 A do 4,5 A 3 W do 4,5 kW CMC 0,23 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 4,5 A do 11 A 3 W do 11 kW CMC 0,17 · 10⁻² · w\nProcedura wewnętrzna; PF = 1; W stałej lokalizacji (S)","reference":"E /I 2/ MAP","norm_bases":["E /I 2/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moc AC","regulatory_area_en":"AC power","outside_premises":false,"location_of_activity":"S","note":"w – wielkość mierzona (W)","note_en":"w – measured value (W)","search_text":"Mierniki mocy czynnej cyfrowe\njednofazowe Wzorcowanie — Moc AC\nZakres:\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 3,3 mA do 9 mA 3 W do 9 W CMC 0,29 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 9 mA do 33 mA 3 W do 33 W CMC 0,17 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 33 mA do 90 mA 3 W do 90 W CMC 0,29 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 90 mA do 330 mA 3 W do 330 W CMC 0,17 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 0,33 A do 0,9 A 3 W do 900 W CMC 0,29 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 0,9 A do 2,2 A 3 W do 2.2 kW CMC 0,17 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 2,2 A do 4,5 A 3 W do 4,5 kW CMC 0,23 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 4,5 A do 11 A 3 W do 11 kW CMC 0,17 · 10⁻² · w\nProcedura wewnętrzna; PF = 1; W stałej lokalizacji (S) E /I 2/ MAP Mierniki mocy czynnej cyfrowe\njednofazowe Wzorcowanie — Moc AC\nZakres:\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 3,3 mA do 9 mA 3 W do 9 W CMC 0,29 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 9 mA do 33 mA 3 W do 33 W CMC 0,17 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 33 mA do 90 mA 3 W do 90 W CMC 0,29 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 90 mA do 330 mA 3 W do 330 W CMC 0,17 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 0,33 A do 0,9 A 3 W do 900 W CMC 0,29 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 0,9 A do 2,2 A 3 W do 2.2 kW CMC 0,17 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 2,2 A do 4,5 A 3 W do 4,5 kW CMC 0,23 · 10⁻² · w\nf = 45 Hz do 65 Hz, |cosφ| = 1, 0,33 V do 1000 V, 4,5 A do 11 A 3 W do 11 kW CMC 0,17 · 10⁻² · w\nProcedura wewnetrzna; PF = 1; W stalej lokalizacji (S) E /I 2/ MAP","search_en":"Digital active power meters single-phase Calibration — AC power Internal procedure; PF = 1; At permanent location (S) AC power Internal procedure PF = 1 At permanent location (S) f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 3,3 mA to 9 mA f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 9 mA to 33 mA f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 33 mA to 90 mA f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 90 mA to 330 mA f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 0,33 A to 0,9 A f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 0,9 A to 2,2 A f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 2,2 A to 4,5 A f = 45 Hz to 65 Hz, |cosφ| = 1, 0,33 V to 1000 V, 4,5 A to 11 A E /I 2/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":25,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — AC-Leistung","parameters_de":[{"name":"f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 3,3 mA bis 9 mA","range":"3 W to 9 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 9 mA bis 33 mA","range":"3 W to 33 W","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 33 mA bis 90 mA","range":"3 W to 90 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 90 mA bis 330 mA","range":"3 W to 330 W","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 0,33 A bis 0,9 A","range":"3 W to 900 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 0,9 A bis 2,2 A","range":"3 W to 2.2 kW","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 2,2 A bis 4,5 A","range":"3 W to 4,5 kW","cmc":"0,23 · 10⁻² · w"},{"name":"f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 4,5 A bis 11 A","range":"3 W to 11 kW","cmc":"0,17 · 10⁻² · w"}],"regulatory_area_de":"AC-Leistung","search_de":"Digitale Wirkleistungsmesser einphasig Kalibrierung — AC-Leistung Internes Verfahren; PF = 1; Am festen Standort (S) AC-Leistung Internes Verfahren PF = 1 Am festen Standort (S) f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 3,3 mA bis 9 mA f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 9 mA bis 33 mA f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 33 mA bis 90 mA f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 90 mA bis 330 mA f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 0,33 A bis 0,9 A f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 0,9 A bis 2,2 A f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 2,2 A bis 4,5 A f = 45 Hz bis 65 Hz, |cosφ| = 1, 0,33 V bis 1000 V, 4,5 A bis 11 A E /I 2/ MAP","technique_de":"Internes Verfahren; PF = 1; Am festen Standort (S)","techniques_de":["Internes Verfahren","PF = 1","Am festen Standort (S)"],"test_object_de":"Digitale Wirkleistungsmesser\neinphasig","methodology_zh":"校准 — 交流功率","parameters_zh":[{"name":"f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 3,3 mA 至 9 mA","range":"3 W to 9 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 9 mA 至 33 mA","range":"3 W to 33 W","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 33 mA 至 90 mA","range":"3 W to 90 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 90 mA 至 330 mA","range":"3 W to 330 W","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 0,33 A 至 0,9 A","range":"3 W to 900 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 0,9 A 至 2,2 A","range":"3 W to 2.2 kW","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 2,2 A 至 4,5 A","range":"3 W to 4,5 kW","cmc":"0,23 · 10⁻² · w"},{"name":"f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 4,5 A 至 11 A","range":"3 W to 11 kW","cmc":"0,17 · 10⁻² · w"}],"regulatory_area_zh":"交流功率","search_zh":"数字有功功率计 单相 校准 — 交流功率 内部程序; PF = 1; 在固定地点 (S) 交流功率 内部程序 PF = 1 在固定地点 (S) f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 3,3 mA 至 9 mA f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 9 mA 至 33 mA f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 33 mA 至 90 mA f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 90 mA 至 330 mA f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 0,33 A 至 0,9 A f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 0,9 A 至 2,2 A f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 2,2 A 至 4,5 A f = 45 Hz 至 65 Hz, |cosφ| = 1, 0,33 V 至 1000 V, 4,5 A 至 11 A E /I 2/ MAP","technique_zh":"内部程序; PF = 1; 在固定地点 (S)","techniques_zh":["内部程序","PF = 1","在固定地点 (S)"],"test_object_zh":"数字有功功率计\n单相","methodology_cs":"Kalibrace — Výkon AC","parameters_cs":[{"name":"f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 3,3 mA až 9 mA","range":"3 W to 9 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 9 mA až 33 mA","range":"3 W to 33 W","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 33 mA až 90 mA","range":"3 W to 90 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 90 mA až 330 mA","range":"3 W to 330 W","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 0,33 A až 0,9 A","range":"3 W to 900 W","cmc":"0,29 · 10⁻² · w"},{"name":"f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 0,9 A až 2,2 A","range":"3 W to 2.2 kW","cmc":"0,17 · 10⁻² · w"},{"name":"f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 2,2 A až 4,5 A","range":"3 W to 4,5 kW","cmc":"0,23 · 10⁻² · w"},{"name":"f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 4,5 A až 11 A","range":"3 W to 11 kW","cmc":"0,17 · 10⁻² · w"}],"regulatory_area_cs":"Výkon AC","search_cs":"Digitální měřiče činného výkonu jednofázové Kalibrace — Výkon AC Vnitřní postup; PF = 1; Ve stálé lokalitě (S) Výkon AC Vnitřní postup PF = 1 Ve stálé lokalitě (S) f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 3,3 mA až 9 mA f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 9 mA až 33 mA f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 33 mA až 90 mA f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 90 mA až 330 mA f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 0,33 A až 0,9 A f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 0,9 A až 2,2 A f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 2,2 A až 4,5 A f = 45 Hz až 65 Hz, |cosφ| = 1, 0,33 V až 1000 V, 4,5 A až 11 A E /I 2/ MAP","technique_cs":"Vnitřní postup; PF = 1; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","PF = 1","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální měřiče činného výkonu\njednofázové"},{"_id":"3f673dd8c1c451e0eddb3e78","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Wskaźniki (mierniki) temperatury w tym regulatory temperatury\nPrzetworniki temperatury\nRejestratory temperatury\nSymulatory temperatury","test_object_en":"Temperature indicators (meters) including temperature controllers\nTemperature transmitters\nTemperature recorders\nTemperature simulators","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electrical simulation of quantities","parameters":[{"name":"","range":"-270 °C do 1820 °C","cmc":"0,02 °C"},{"name":"","range":"-200°C do 0 °C","cmc":"0,002 °C"},{"name":"","range":"0°C do 850 °C","cmc":"7 · 10⁻⁶ · t + 0,002 °C"}],"parameters_en":[{"name":"","range":"-270 °C to 1820 °C","cmc":"0,02 °C"},{"name":"","range":"-200°C to 0 °C","cmc":"0,002 °C"},{"name":"","range":"0°C to 850 °C","cmc":"7 · 10⁻⁶ · t + 0,002 °C"}],"technique":"Metoda pośrednia elektryczna; W stałej lokalizacji (S)","technique_en":"Indirect electrical method; At permanent location (S)","techniques":["Metoda pośrednia elektryczna","W stałej lokalizacji (S)"],"techniques_en":["Indirect electrical method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-270 °C do 1820 °C CMC 0,02 °C\n-200°C do 0 °C CMC 0,002 °C\n0°C do 850 °C CMC 7 · 10⁻⁶ · t + 0,002 °C\nMetoda pośrednia elektryczna; W stałej lokalizacji (S)","reference":"EURAMET cg-11 v.2.0","norm_bases":["EURAMET cg-11 v.2.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electrical simulation of quantities","outside_premises":false,"location_of_activity":"S","note":"t – wielkość mierzona (°C)","note_en":"t – measured value (°C)","search_text":"Wskaźniki (mierniki) temperatury w tym regulatory temperatury\nPrzetworniki temperatury\nRejestratory temperatury\nSymulatory temperatury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-270 °C do 1820 °C CMC 0,02 °C\n-200°C do 0 °C CMC 0,002 °C\n0°C do 850 °C CMC 7 · 10⁻⁶ · t + 0,002 °C\nMetoda pośrednia elektryczna; W stałej lokalizacji (S) EURAMET cg-11 v.2.0 Wskazniki (mierniki) temperatury w tym regulatory temperatury\nPrzetworniki temperatury\nRejestratory temperatury\nSymulatory temperatury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\n-270 °C do 1820 °C CMC 0,02 °C\n-200°C do 0 °C CMC 0,002 °C\n0°C do 850 °C CMC 7 · 10⁻⁶ · t + 0,002 °C\nMetoda posrednia elektryczna; W stalej lokalizacji (S) EURAMET cg-11 v.2.0","search_en":"Temperature indicators (meters) including temperature controllers Temperature transmitters Temperature recorders Temperature simulators Calibration — Electrical simulation of quantities Indirect electrical method; At permanent location (S) Electrical simulation of quantities Indirect electrical method At permanent location (S) EURAMET cg-11 v.2.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":26,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-270 °C to 1820 °C","cmc":"0,02 °C"},{"name":"","range":"-200°C to 0 °C","cmc":"0,002 °C"},{"name":"","range":"0°C to 850 °C","cmc":"7 · 10⁻⁶ · t + 0,002 °C"}],"regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturanzeiger (-messgeräte) einschließlich Temperaturregler Temperaturmessumformer Temperaturschreiber Temperatursimulatoren Kalibrierung — Elektrische Simulation von Größen Elektrisches indirektes Verfahren; Am festen Standort (S) Elektrische Simulation von Größen Elektrisches indirektes Verfahren Am festen Standort (S) EURAMET cg-11 v.2.0","technique_de":"Elektrisches indirektes Verfahren; Am festen Standort (S)","techniques_de":["Elektrisches indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Temperaturanzeiger (-messgeräte) einschließlich Temperaturregler\nTemperaturmessumformer\nTemperaturschreiber\nTemperatursimulatoren","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-270 °C to 1820 °C","cmc":"0,02 °C"},{"name":"","range":"-200°C to 0 °C","cmc":"0,002 °C"},{"name":"","range":"0°C to 850 °C","cmc":"7 · 10⁻⁶ · t + 0,002 °C"}],"regulatory_area_zh":"量值的电模拟","search_zh":"温度指示仪（测量仪），包括温度调节器 温度变送器 温度记录仪 温度模拟器 校准 — 物理量的电模拟 电气间接法; 在固定地点 (S) 量值的电模拟 电气间接法 在固定地点 (S) EURAMET cg-11 v.2.0","technique_zh":"电气间接法; 在固定地点 (S)","techniques_zh":["电气间接法","在固定地点 (S)"],"test_object_zh":"温度指示仪（测量仪），包括温度调节器\n温度变送器\n温度记录仪\n温度模拟器","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-270 °C to 1820 °C","cmc":"0,02 °C"},{"name":"","range":"-200°C to 0 °C","cmc":"0,002 °C"},{"name":"","range":"0°C to 850 °C","cmc":"7 · 10⁻⁶ · t + 0,002 °C"}],"regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Ukazatele (měřiče) teploty včetně regulátorů teploty Převodníky teploty Záznamníky teploty Simulátory teploty Kalibrace — Elektrická simulace veličin Elektrická nepřímá metoda; Ve stálé lokalitě (S) Elektrická simulace veličin Elektrická nepřímá metoda Ve stálé lokalitě (S) EURAMET cg-11 v.2.0","technique_cs":"Elektrická nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Elektrická nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Ukazatele (měřiče) teploty včetně regulátorů teploty\nPřevodníky teploty\nZáznamníky teploty\nSimulátory teploty"},{"_id":"d9a4668382d4819e1b0d9752","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Wskaźniki (mierniki) temperatury w tym regulatory temperatury\nPrzetworniki temperatury\nRejestratory temperatury\nSymulatory temperatury","test_object_en":"Temperature indicators (meters) including temperature controllers\nTemperature transmitters\nTemperature recorders\nTemperature simulators","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electrical simulation of quantities","parameters":[{"name":"","range":"-270°C do 1820 °C","cmc":"0,2 °C"},{"name":"","range":"-200°C do 850 °C","cmc":"0,015 °C"}],"parameters_en":[{"name":"","range":"-270°C to 1820 °C","cmc":"0,2 °C"},{"name":"","range":"-200°C to 850 °C","cmc":"0,015 °C"}],"technique":"Metoda pośrednia elektryczna; Poza stałą lokalizacją (P)","technique_en":"Indirect electrical method; Outside of permanent location (P)","techniques":["Metoda pośrednia elektryczna","Poza stałą lokalizacją (P)"],"techniques_en":["Indirect electrical method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-270°C do 1820 °C CMC 0,2 °C\n-200°C do 850 °C CMC 0,015 °C\nMetoda pośrednia elektryczna; Poza stałą lokalizacją (P)","reference":"EURAMET cg-11 v.2.0","norm_bases":["EURAMET cg-11 v.2.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electrical simulation of quantities","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Wskaźniki (mierniki) temperatury w tym regulatory temperatury\nPrzetworniki temperatury\nRejestratory temperatury\nSymulatory temperatury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-270°C do 1820 °C CMC 0,2 °C\n-200°C do 850 °C CMC 0,015 °C\nMetoda pośrednia elektryczna; Poza stałą lokalizacją (P) EURAMET cg-11 v.2.0 Wskazniki (mierniki) temperatury w tym regulatory temperatury\nPrzetworniki temperatury\nRejestratory temperatury\nSymulatory temperatury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\n-270°C do 1820 °C CMC 0,2 °C\n-200°C do 850 °C CMC 0,015 °C\nMetoda posrednia elektryczna; Poza stala lokalizacja (P) EURAMET cg-11 v.2.0","search_en":"Temperature indicators (meters) including temperature controllers Temperature transmitters Temperature recorders Temperature simulators Calibration — Electrical simulation of quantities Indirect electrical method; Outside of permanent location (P) Electrical simulation of quantities Indirect electrical method Outside of permanent location (P) EURAMET cg-11 v.2.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":27,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-270°C to 1820 °C","cmc":"0,2 °C"},{"name":"","range":"-200°C to 850 °C","cmc":"0,015 °C"}],"regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturanzeiger (-messgeräte) einschließlich Temperaturregler Temperaturmessumformer Temperaturschreiber Temperatursimulatoren Kalibrierung — Elektrische Simulation von Größen Elektrisches indirektes Verfahren; Außerhalb des festen Standorts (P) Elektrische Simulation von Größen Elektrisches indirektes Verfahren Außerhalb des festen Standorts (P) EURAMET cg-11 v.2.0","technique_de":"Elektrisches indirektes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Elektrisches indirektes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Temperaturanzeiger (-messgeräte) einschließlich Temperaturregler\nTemperaturmessumformer\nTemperaturschreiber\nTemperatursimulatoren","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-270°C to 1820 °C","cmc":"0,2 °C"},{"name":"","range":"-200°C to 850 °C","cmc":"0,015 °C"}],"regulatory_area_zh":"量值的电模拟","search_zh":"温度指示仪（测量仪），包括温度调节器 温度变送器 温度记录仪 温度模拟器 校准 — 物理量的电模拟 电气间接法; 固定地点以外 (P) 量值的电模拟 电气间接法 固定地点以外 (P) EURAMET cg-11 v.2.0","technique_zh":"电气间接法; 固定地点以外 (P)","techniques_zh":["电气间接法","固定地点以外 (P)"],"test_object_zh":"温度指示仪（测量仪），包括温度调节器\n温度变送器\n温度记录仪\n温度模拟器","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-270°C to 1820 °C","cmc":"0,2 °C"},{"name":"","range":"-200°C to 850 °C","cmc":"0,015 °C"}],"regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Ukazatele (měřiče) teploty včetně regulátorů teploty Převodníky teploty Záznamníky teploty Simulátory teploty Kalibrace — Elektrická simulace veličin Elektrická nepřímá metoda; Mimo stálou lokalitu (P) Elektrická simulace veličin Elektrická nepřímá metoda Mimo stálou lokalitu (P) EURAMET cg-11 v.2.0","technique_cs":"Elektrická nepřímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Elektrická nepřímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Ukazatele (měřiče) teploty včetně regulátorů teploty\nPřevodníky teploty\nZáznamníky teploty\nSimulátory teploty"},{"_id":"994e55c040fe398f0f753654","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki przedziału czasu","test_object_en":"Time interval meters","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"0 h do 24 h","cmc":"0,35 s + 1 · 10⁻⁵ · τ"}],"parameters_en":[{"name":"","range":"0 h to 24 h","cmc":"0,35 s + 1 · 10⁻⁵ · τ"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\n0 h do 24 h CMC 0,35 s + 1 · 10⁻⁵ · τ\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"E /I 5/ MAP","norm_bases":["E /I 5/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":"τ – wartość mierzonego przedziału czasu (s)","note_en":"τ – value of the measured time interval (s)","search_text":"Mierniki przedziału czasu Wzorcowanie — Czas (przedział czasu)\n0 h do 24 h CMC 0,35 s + 1 · 10⁻⁵ · τ\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) E /I 5/ MAP Mierniki przedzialu czasu Wzorcowanie — Czas (przedzial czasu)\n0 h do 24 h CMC 0,35 s + 1 · 10⁻⁵ · τ\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) E /I 5/ MAP","search_en":"Time interval meters Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) E /I 5/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":28,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"0 h to 24 h","cmc":"0,35 s + 1 · 10⁻⁵ · τ"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Zeitintervallmessgeräte Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) E /I 5/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Zeitintervallmessgeräte","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"0 h to 24 h","cmc":"0,35 s + 1 · 10⁻⁵ · τ"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"时间间隔测量仪 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) E /I 5/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"时间间隔测量仪","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"0 h to 24 h","cmc":"0,35 s + 1 · 10⁻⁵ · τ"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Měřiče časového intervalu Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) E /I 5/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče časového intervalu"},{"_id":"dbb9311f33c21629c7db5ebd","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Mierniki przedziału czasu","test_object_en":"Time interval meters","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"0 h do 24 h","cmc":"0,35 s + 1 · 10⁻⁵ · τ"}],"parameters_en":[{"name":"","range":"0 h to 24 h","cmc":"0,35 s + 1 · 10⁻⁵ · τ"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\n0 h do 24 h CMC 0,35 s + 1 · 10⁻⁵ · τ\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"P4 / MAP\nE /I 5/ MAP","norm_bases":["P4 / MAP","E /I 5/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":true,"location_of_activity":"P","note":"τ – wartość mierzonego przedziału czasu (s)","note_en":"τ – value of the measured time interval (s)","search_text":"Mierniki przedziału czasu Wzorcowanie — Czas (przedział czasu)\n0 h do 24 h CMC 0,35 s + 1 · 10⁻⁵ · τ\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) P4 / MAP\nE /I 5/ MAP Mierniki przedzialu czasu Wzorcowanie — Czas (przedzial czasu)\n0 h do 24 h CMC 0,35 s + 1 · 10⁻⁵ · τ\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) P4 / MAP\nE /I 5/ MAP","search_en":"Time interval meters Calibration — Time (time interval) Internal procedure; Direct method; Outside of permanent location (P) Time (time interval) Internal procedure Direct method Outside of permanent location (P) P4 / MAP E /I 5/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":29,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"0 h to 24 h","cmc":"0,35 s + 1 · 10⁻⁵ · τ"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Zeitintervallmessgeräte Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) P4 / MAP E /I 5/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Zeitintervallmessgeräte","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"0 h to 24 h","cmc":"0,35 s + 1 · 10⁻⁵ · τ"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"时间间隔测量仪 校准 — 时间（时间间隔） 内部程序；直接法；固定地点以外 (P) 时间（时间间隔） 内部程序 直接法 固定地点以外 (P) P4 / MAP E /I 5/ MAP","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"时间间隔测量仪","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"0 h to 24 h","cmc":"0,35 s + 1 · 10⁻⁵ · τ"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Měřiče časového intervalu Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Čas (časový interval) Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) P4 / MAP E /I 5/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Měřiče časového intervalu"},{"_id":"6a51932f9f4d59e055497653","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Higrometry","test_object_en":"Hygrometers","methodology":"Wzorcowanie — Temperatura punktu rosy","methodology_en":"Calibration — Dew point temperature","parameters":[{"name":"","range":"-20 °C dp do 20 °C dp","cmc":"0,2 °C dp"}],"parameters_en":[{"name":"","range":"-20 °C dp to 20 °C dp","cmc":"0,2 °C dp"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura punktu rosy\n-20 °C dp do 20 °C dp CMC 0,2 °C dp\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"W2/ MAP","norm_bases":["W2/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura punktu rosy","regulatory_area_en":"Dew point temperature","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Higrometry Wzorcowanie — Temperatura punktu rosy\n-20 °C dp do 20 °C dp CMC 0,2 °C dp\nProcedura wewnętrzna; W stałej lokalizacji (S) W2/ MAP Higrometry Wzorcowanie — Temperatura punktu rosy\n-20 °C dp do 20 °C dp CMC 0,2 °C dp\nProcedura wewnetrzna; W stalej lokalizacji (S) W2/ MAP","search_en":"Hygrometers Calibration — Dew point temperature Internal procedure; At permanent location (S) Dew point temperature Internal procedure At permanent location (S) W2/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":30,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Taupunkttemperatur","parameters_de":[{"name":"","range":"-20 °C dp to 20 °C dp","cmc":"0,2 °C dp"}],"regulatory_area_de":"Taupunkttemperatur","search_de":"Hygrometer Kalibrierung — Taupunkttemperatur Internes Verfahren; Am festen Standort (S) Taupunkttemperatur Internes Verfahren Am festen Standort (S) W2/ MAP","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Hygrometer","methodology_zh":"校准 — 露点温度","parameters_zh":[{"name":"","range":"-20 °C dp to 20 °C dp","cmc":"0,2 °C dp"}],"regulatory_area_zh":"露点温度","search_zh":"湿度计 校准 — 露点温度 内部程序；在固定地点 (S) 露点温度 内部程序 在固定地点 (S) W2/ MAP","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"湿度计","methodology_cs":"Kalibrace — Teplota rosného bodu","parameters_cs":[{"name":"","range":"-20 °C dp to 20 °C dp","cmc":"0,2 °C dp"}],"regulatory_area_cs":"Teplota rosného bodu","search_cs":"Vlhkoměry Kalibrace — Teplota rosného bodu Vnitřní postup; Ve stálé lokalitě (S) Teplota rosného bodu Vnitřní postup Ve stálé lokalitě (S) W2/ MAP","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Vlhkoměry"},{"_id":"31b8fb988403f4fddd091ed8","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Higrometry\nTermohigrometry\nPsychrometry\nPrzetworniki","test_object_en":"Hygrometers\nThermohygrometers\nPsychrometers\nTransmitters","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"37 %rh do 85 %rh","range":"37 %rh","cmc":"1,0 %rh"},{"name":"37 %rh do 85 %rh","range":"85 %rh","cmc":"1,7 %rh"},{"name":"temperatura","range":"-20 °C do -5 °C","cmc":"0,15 °C"},{"name":"20 %rh do 90 %rh","range":"20 %rh","cmc":"1,0 %rh"},{"name":"20 %rh do 90 %rh","range":"90 %rh","cmc":"1,7 %rh"},{"name":"temperatura","range":"-5 °C do 0 °C","cmc":"0,15 °C"},{"name":"","range":"10 %rh do 98 %rh","cmc":"0,6 %rh"},{"name":"temperatura","range":"0 °C do 80 °C","cmc":"0,15 °C"},{"name":"10 %rh do 98 %rh","range":"10 %rh","cmc":"1,0 %rh"},{"name":"10 %rh do 98 %rh","range":"98 %rh","cmc":"2,0 %rh"},{"name":"temperatura","range":"80 °C do 90 °C","cmc":"0,15 °C"}],"parameters_en":[{"name":"37 %rh to 85 %rh","range":"37 %rh","cmc":"1,0 %rh"},{"name":"37 %rh to 85 %rh","range":"85 %rh","cmc":"1,7 %rh"},{"name":"temperature","range":"-20 °C to -5 °C","cmc":"0,15 °C"},{"name":"20 %rh to 90 %rh","range":"20 %rh","cmc":"1,0 %rh"},{"name":"20 %rh to 90 %rh","range":"90 %rh","cmc":"1,7 %rh"},{"name":"temperature","range":"-5 °C to 0 °C","cmc":"0,15 °C"},{"name":"","range":"10 %rh to 98 %rh","cmc":"0,6 %rh"},{"name":"temperature","range":"0 °C to 80 °C","cmc":"0,15 °C"},{"name":"10 %rh to 98 %rh","range":"10 %rh","cmc":"1,0 %rh"},{"name":"10 %rh to 98 %rh","range":"98 %rh","cmc":"2,0 %rh"},{"name":"temperature","range":"80 °C to 90 °C","cmc":"0,15 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nZakres:\n37 %rh do 85 %rh 37 %rh CMC 1,0 %rh\n37 %rh do 85 %rh 85 %rh CMC 1,7 %rh\ntemperatura -20 °C do -5 °C CMC 0,15 °C\n20 %rh do 90 %rh 20 %rh CMC 1,0 %rh\n20 %rh do 90 %rh 90 %rh CMC 1,7 %rh\ntemperatura -5 °C do 0 °C CMC 0,15 °C\n10 %rh do 98 %rh CMC 0,6 %rh\ntemperatura 0 °C do 80 °C CMC 0,15 °C\n10 %rh do 98 %rh 10 %rh CMC 1,0 %rh\n10 %rh do 98 %rh 98 %rh CMC 2,0 %rh\ntemperatura 80 °C do 90 °C CMC 0,15 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"W1/ MAP","norm_bases":["W1/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Higrometry\nTermohigrometry\nPsychrometry\nPrzetworniki Wzorcowanie — Wilgotność względna\nZakres:\n37 %rh do 85 %rh 37 %rh CMC 1,0 %rh\n37 %rh do 85 %rh 85 %rh CMC 1,7 %rh\ntemperatura -20 °C do -5 °C CMC 0,15 °C\n20 %rh do 90 %rh 20 %rh CMC 1,0 %rh\n20 %rh do 90 %rh 90 %rh CMC 1,7 %rh\ntemperatura -5 °C do 0 °C CMC 0,15 °C\n10 %rh do 98 %rh CMC 0,6 %rh\ntemperatura 0 °C do 80 °C CMC 0,15 °C\n10 %rh do 98 %rh 10 %rh CMC 1,0 %rh\n10 %rh do 98 %rh 98 %rh CMC 2,0 %rh\ntemperatura 80 °C do 90 °C CMC 0,15 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) W1/ MAP Higrometry\nTermohigrometry\nPsychrometry\nPrzetworniki Wzorcowanie — Wilgotnosc wzgledna\nZakres:\n37 %rh do 85 %rh 37 %rh CMC 1,0 %rh\n37 %rh do 85 %rh 85 %rh CMC 1,7 %rh\ntemperatura -20 °C do -5 °C CMC 0,15 °C\n20 %rh do 90 %rh 20 %rh CMC 1,0 %rh\n20 %rh do 90 %rh 90 %rh CMC 1,7 %rh\ntemperatura -5 °C do 0 °C CMC 0,15 °C\n10 %rh do 98 %rh CMC 0,6 %rh\ntemperatura 0 °C do 80 °C CMC 0,15 °C\n10 %rh do 98 %rh 10 %rh CMC 1,0 %rh\n10 %rh do 98 %rh 98 %rh CMC 2,0 %rh\ntemperatura 80 °C do 90 °C CMC 0,15 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) W1/ MAP","search_en":"Hygrometers Thermohygrometers Psychrometers Transmitters Calibration — Relative humidity Internal procedure; At permanent location (S) Relative humidity Internal procedure At permanent location (S) 37 %rh to 85 %rh 37 %rh to 85 %rh temperature 20 %rh to 90 %rh 20 %rh to 90 %rh temperature temperature 10 %rh to 98 %rh 10 %rh to 98 %rh temperature W1/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":31,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"37 %rh bis 85 %rh","range":"37 %rh","cmc":"1,0 %rh"},{"name":"37 %rh bis 85 %rh","range":"85 %rh","cmc":"1,7 %rh"},{"name":"Temperatur","range":"-20 °C to -5 °C","cmc":"0,15 °C"},{"name":"20 %rh bis 90 %rh","range":"20 %rh","cmc":"1,0 %rh"},{"name":"20 %rh bis 90 %rh","range":"90 %rh","cmc":"1,7 %rh"},{"name":"Temperatur","range":"-5 °C to 0 °C","cmc":"0,15 °C"},{"name":"","range":"10 %rh bis 98 %rh","cmc":"0,6 %rh"},{"name":"Temperatur","range":"0 °C to 80 °C","cmc":"0,15 °C"},{"name":"10 %rh bis 98 %rh","range":"10 %rh","cmc":"1,0 %rh"},{"name":"10 %rh bis 98 %rh","range":"98 %rh","cmc":"2,0 %rh"},{"name":"Temperatur","range":"80 °C to 90 °C","cmc":"0,15 °C"}],"regulatory_area_de":"Relative Feuchte","search_de":"Hygrometer Thermohygrometer Psychrometer Messumformer Kalibrierung — Relative Feuchte Internes Verfahren; Am festen Standort (S) Relative Feuchte Internes Verfahren Am festen Standort (S) 37 %rh bis 85 %rh 37 %rh bis 85 %rh Temperatur 20 %rh bis 90 %rh 20 %rh bis 90 %rh Temperatur Temperatur 10 %rh bis 98 %rh 10 %rh bis 98 %rh Temperatur W1/ MAP","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Hygrometer\nThermohygrometer\nPsychrometer\nMessumformer","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"37 %rh 至 85 %rh","range":"37 %rh","cmc":"1,0 %rh"},{"name":"37 %rh 至 85 %rh","range":"85 %rh","cmc":"1,7 %rh"},{"name":"温度","range":"-20 °C to -5 °C","cmc":"0,15 °C"},{"name":"20 %rh 至 90 %rh","range":"20 %rh","cmc":"1,0 %rh"},{"name":"20 %rh 至 90 %rh","range":"90 %rh","cmc":"1,7 %rh"},{"name":"温度","range":"-5 °C to 0 °C","cmc":"0,15 °C"},{"name":"","range":"10 %rh 至 98 %rh","cmc":"0,6 %rh"},{"name":"温度","range":"0 °C to 80 °C","cmc":"0,15 °C"},{"name":"10 %rh 至 98 %rh","range":"10 %rh","cmc":"1,0 %rh"},{"name":"10 %rh 至 98 %rh","range":"98 %rh","cmc":"2,0 %rh"},{"name":"温度","range":"80 °C to 90 °C","cmc":"0,15 °C"}],"regulatory_area_zh":"相对湿度","search_zh":"湿度计 温湿度计 干湿表 变送器 校准 — 相对湿度 内部程序；在固定地点 (S) 相对湿度 内部程序 在固定地点 (S) 37 %rh 至 85 %rh 37 %rh 至 85 %rh 温度 20 %rh 至 90 %rh 20 %rh 至 90 %rh 温度 温度 10 %rh 至 98 %rh 10 %rh 至 98 %rh 温度 W1/ MAP","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"湿度计\n温湿度计\n干湿表\n变送器","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"37 %rh až 85 %rh","range":"37 %rh","cmc":"1,0 %rh"},{"name":"37 %rh až 85 %rh","range":"85 %rh","cmc":"1,7 %rh"},{"name":"teplota","range":"-20 °C to -5 °C","cmc":"0,15 °C"},{"name":"20 %rh do 90 %rh","range":"20 %rh","cmc":"1,0 %rh"},{"name":"20 %rh do 90 %rh","range":"90 %rh","cmc":"1,7 %rh"},{"name":"teplota","range":"-5 °C to 0 °C","cmc":"0,15 °C"},{"name":"","range":"10 %rh až 98 %rh","cmc":"0,6 %rh"},{"name":"teplota","range":"0 °C to 80 °C","cmc":"0,15 °C"},{"name":"10 %rh až 98 %rh","range":"10 %rh","cmc":"1,0 %rh"},{"name":"10 %rh až 98 %rh","range":"98 %rh","cmc":"2,0 %rh"},{"name":"teplota","range":"80 °C to 90 °C","cmc":"0,15 °C"}],"regulatory_area_cs":"Relativní vlhkost","search_cs":"Vlhkoměry Termohygrometry Psychrometry Snímače Kalibrace — Relativní vlhkost Vnitřní postup; Ve stálé lokalitě (S) Relativní vlhkost Vnitřní postup Ve stálé lokalitě (S) 37 %rh až 85 %rh 37 %rh až 85 %rh teplota 20 %rh do 90 %rh 20 %rh do 90 %rh teplota teplota 10 %rh až 98 %rh 10 %rh až 98 %rh teplota W1/ MAP","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Vlhkoměry\nTermohygrometry\nPsychrometry\nSnímače"},{"_id":"39caabe245583ddec27ec639","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Komory klimatyczne","test_object_en":"Climatic chambers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"","range":"20 %rh do 98 %rh","cmc":"2,0 %rh 1)"},{"name":"temperatura","range":"0 °C do 10 °C","cmc":"0,20 °C 1)"},{"name":"","range":"10 %rh do 98 %rh","cmc":"2,0 %rh 1)"},{"name":"temperatura","range":"10 °C do 80 °C","cmc":"0,20 °C 1)"},{"name":"","range":"10 %rh do 98 %rh","cmc":"2,5 %rh 1)"},{"name":"temperatura","range":"80 °C do 90 °C","cmc":"0,20 °C 1)"}],"parameters_en":[{"name":"","range":"20 %rh to 98 %rh","cmc":"2,0 %rh 1)"},{"name":"temperature","range":"0 °C to 10 °C","cmc":"0,20 °C 1)"},{"name":"","range":"10 %rh to 98 %rh","cmc":"2,0 %rh 1)"},{"name":"temperature","range":"10 °C to 80 °C","cmc":"0,20 °C 1)"},{"name":"","range":"10 %rh to 98 %rh","cmc":"2,5 %rh 1)"},{"name":"temperature","range":"80 °C to 90 °C","cmc":"0,20 °C 1)"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nZakres:\n20 %rh do 98 %rh CMC 2,0 %rh 1)\ntemperatura 0 °C do 10 °C CMC 0,20 °C 1)\n10 %rh do 98 %rh CMC 2,0 %rh 1)\ntemperatura 10 °C do 80 °C CMC 0,20 °C 1)\n10 %rh do 98 %rh CMC 2,5 %rh 1)\ntemperatura 80 °C do 90 °C CMC 0,20 °C 1)\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"T /I 11/ MAP\nP4 / MAP","norm_bases":["T /I 11/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Komory klimatyczne Wzorcowanie — Wilgotność względna\nZakres:\n20 %rh do 98 %rh CMC 2,0 %rh 1)\ntemperatura 0 °C do 10 °C CMC 0,20 °C 1)\n10 %rh do 98 %rh CMC 2,0 %rh 1)\ntemperatura 10 °C do 80 °C CMC 0,20 °C 1)\n10 %rh do 98 %rh CMC 2,5 %rh 1)\ntemperatura 80 °C do 90 °C CMC 0,20 °C 1)\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) T /I 11/ MAP\nP4 / MAP Komory klimatyczne Wzorcowanie — Wilgotnosc wzgledna\nZakres:\n20 %rh do 98 %rh CMC 2,0 %rh 1)\ntemperatura 0 °C do 10 °C CMC 0,20 °C 1)\n10 %rh do 98 %rh CMC 2,0 %rh 1)\ntemperatura 10 °C do 80 °C CMC 0,20 °C 1)\n10 %rh do 98 %rh CMC 2,5 %rh 1)\ntemperatura 80 °C do 90 °C CMC 0,20 °C 1)\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) T /I 11/ MAP\nP4 / MAP","search_en":"Climatic chambers Calibration — Relative humidity Internal procedure; At permanent location (S) and outside of it (P) Relative humidity Internal procedure At permanent location (S) and outside of it (P) temperature temperature temperature T /I 11/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":32,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"","range":"20 %rh bis 98 %rh","cmc":"2,0 %rh 1)"},{"name":"Temperatur","range":"0 °C to 10 °C","cmc":"0,20 °C 1)"},{"name":"","range":"10 %rh bis 98 %rh","cmc":"2,0 %rh 1)"},{"name":"Temperatur","range":"10 °C bis 80 °C","cmc":"0,20 °C 1)"},{"name":"","range":"10 %rh bis 98 %rh","cmc":"2,5 %rh 1)"},{"name":"Temperatur","range":"80 °C to 90 °C","cmc":"0,20 °C 1)"}],"regulatory_area_de":"Relative Feuchte","search_de":"Klimakammern Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Relative Feuchte Internes Verfahren Am festen Standort (S) und außerhalb (P) Temperatur Temperatur Temperatur T /I 11/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Klimakammern","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"","range":"20 %rh 至 98 %rh","cmc":"2,0 %rh 1)"},{"name":"温度","range":"0 °C to 10 °C","cmc":"0,20 °C 1)"},{"name":"","range":"10 %rh 至 98 %rh","cmc":"2,0 %rh 1)"},{"name":"温度","range":"10 °C to 80 °C","cmc":"0,20 °C 1)"},{"name":"","range":"10 %rh 至 98 %rh","cmc":"2,5 %rh 1)"},{"name":"温度","range":"80 °C to 90 °C","cmc":"0,20 °C 1)"}],"regulatory_area_zh":"相对湿度","search_zh":"气候箱 校准 — 相对湿度 内部程序；在固定地点 (S) 及固定地点以外 (P) 相对湿度 内部程序 在固定地点 (S) 及固定地点以外 (P) 温度 温度 温度 T /I 11/ MAP P4 / MAP","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"气候箱","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"","range":"20 %rh do 98 %rh","cmc":"2,0 %rh 1)"},{"name":"teplota","range":"0 °C to 10 °C","cmc":"0,20 °C 1)"},{"name":"","range":"10 %rh až 98 %rh","cmc":"2,0 %rh 1)"},{"name":"teplota","range":"10 °C to 80 °C","cmc":"0,20 °C 1)"},{"name":"","range":"10 %rh až 98 %rh","cmc":"2,5 %rh 1)"},{"name":"teplota","range":"80 °C to 90 °C","cmc":"0,20 °C 1)"}],"regulatory_area_cs":"Relativní vlhkost","search_cs":"Klimatické komory Kalibrace — Relativní vlhkost Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Relativní vlhkost Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) teplota teplota teplota T /I 11/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Klimatické komory"},{"_id":"8c19fc87a98493755bac52a5","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Higrometry\nTermohigrometry\nPsychrometry\nPrzetworniki","test_object_en":"Hygrometers\nThermohygrometers\nPsychrometers\nTransmitters","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"","range":"10 %rh do 98 %rh","cmc":"2,0 %rh"},{"name":"temperatura","range":"10 °C do 80 °C","cmc":"0,20 °C"},{"name":"","range":"20 %rh do 98 %rh","cmc":"2,0 %rh"},{"name":"temperatura","range":"0 °C do 10 °C","cmc":"0,20 °C"}],"parameters_en":[{"name":"","range":"10 %rh to 98 %rh","cmc":"2,0 %rh"},{"name":"temperature","range":"10 °C to 80 °C","cmc":"0,20 °C"},{"name":"","range":"20 %rh to 98 %rh","cmc":"2,0 %rh"},{"name":"temperature","range":"0 °C to 10 °C","cmc":"0,20 °C"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nZakres:\n10 %rh do 98 %rh CMC 2,0 %rh\ntemperatura 10 °C do 80 °C CMC 0,20 °C\n20 %rh do 98 %rh CMC 2,0 %rh\ntemperatura 0 °C do 10 °C CMC 0,20 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"W1/ MAP\nP4 / MAP","norm_bases":["W1/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Higrometry\nTermohigrometry\nPsychrometry\nPrzetworniki Wzorcowanie — Wilgotność względna\nZakres:\n10 %rh do 98 %rh CMC 2,0 %rh\ntemperatura 10 °C do 80 °C CMC 0,20 °C\n20 %rh do 98 %rh CMC 2,0 %rh\ntemperatura 0 °C do 10 °C CMC 0,20 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P) W1/ MAP\nP4 / MAP Higrometry\nTermohigrometry\nPsychrometry\nPrzetworniki Wzorcowanie — Wilgotnosc wzgledna\nZakres:\n10 %rh do 98 %rh CMC 2,0 %rh\ntemperatura 10 °C do 80 °C CMC 0,20 °C\n20 %rh do 98 %rh CMC 2,0 %rh\ntemperatura 0 °C do 10 °C CMC 0,20 °C\nProcedura wewnetrzna; Poza stala lokalizacja (P) W1/ MAP\nP4 / MAP","search_en":"Hygrometers Thermohygrometers Psychrometers Transmitters Calibration — Relative humidity Internal procedure; Outside of permanent location (P) Relative humidity Internal procedure Outside of permanent location (P) temperature temperature W1/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":33,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"","range":"10 %rh bis 98 %rh","cmc":"2,0 %rh"},{"name":"Temperatur","range":"10 °C bis 80 °C","cmc":"0,20 °C"},{"name":"","range":"20 %rh bis 98 %rh","cmc":"2,0 %rh"},{"name":"Temperatur","range":"0 °C to 10 °C","cmc":"0,20 °C"}],"regulatory_area_de":"Relative Feuchte","search_de":"Hygrometer Thermohygrometer Psychrometer Messumformer Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Relative Feuchte Internes Verfahren Außerhalb des festen Standorts (P) Temperatur Temperatur W1/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Hygrometer\nThermohygrometer\nPsychrometer\nMessumformer","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"","range":"10 %rh 至 98 %rh","cmc":"2,0 %rh"},{"name":"温度","range":"10 °C to 80 °C","cmc":"0,20 °C"},{"name":"","range":"20 %rh 至 98 %rh","cmc":"2,0 %rh"},{"name":"温度","range":"0 °C to 10 °C","cmc":"0,20 °C"}],"regulatory_area_zh":"相对湿度","search_zh":"湿度计 温湿度计 干湿表 变送器 校准 — 相对湿度 内部程序；固定地点以外 (P) 相对湿度 内部程序 固定地点以外 (P) 温度 温度 W1/ MAP P4 / MAP","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"湿度计\n温湿度计\n干湿表\n变送器","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"","range":"10 %rh až 98 %rh","cmc":"2,0 %rh"},{"name":"teplota","range":"10 °C to 80 °C","cmc":"0,20 °C"},{"name":"","range":"20 %rh do 98 %rh","cmc":"2,0 %rh"},{"name":"teplota","range":"0 °C to 10 °C","cmc":"0,20 °C"}],"regulatory_area_cs":"Relativní vlhkost","search_cs":"Vlhkoměry Termohygrometry Psychrometry Snímače Kalibrace — Relativní vlhkost Vnitřní postup; Mimo stálé pracoviště (P) Relativní vlhkost Vnitřní postup Mimo stálou lokalitu (P) teplota teplota W1/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Vlhkoměry\nTermohygrometry\nPsychrometry\nSnímače"},{"_id":"165c755b4c647b61b806938c","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia\n- ciśnienie względne: podciśnienie i nadciśnienie (czynnik gaz)","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\nPressure transmitters\n- gauge pressure: negative and positive pressure (gas medium)","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"-0,1 MPa do -0,09 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-0,09 MPa do -0,015 MPa","cmc":"16 Pa"},{"name":"","range":"-0,015 MPa do -0,009 MPa","cmc":"1 · 10⁻⁴ · p + 0,01 Pa"},{"name":"","range":"-0,009 MPa do 0,009 MPa","cmc":"0,9 Pa"},{"name":"","range":"0,009 MPa do 0,015 MPa","cmc":"1 · 10⁻⁴ · p + 0,01 Pa"},{"name":"","range":"0,015 MPa do 0,1 MPa","cmc":"16 Pa"},{"name":"","range":"0,1 MPa do 0,6 MPa","cmc":"60,3 Pa"},{"name":"","range":"0,6 MPa do 2 MPa","cmc":"1 · 10⁻⁴ · p + 1 Pa"}],"parameters_en":[{"name":"","range":"-0,1 MPa to -0,09 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-0,09 MPa to -0,015 MPa","cmc":"16 Pa"},{"name":"","range":"-0,015 MPa to -0,009 MPa","cmc":"1 · 10⁻⁴ · p + 0,01 Pa"},{"name":"","range":"-0,009 MPa to 0,009 MPa","cmc":"0,9 Pa"},{"name":"","range":"0,009 MPa to 0,015 MPa","cmc":"1 · 10⁻⁴ · p + 0,01 Pa"},{"name":"","range":"0,015 MPa to 0,1 MPa","cmc":"16 Pa"},{"name":"","range":"0,1 MPa to 0,6 MPa","cmc":"60,3 Pa"},{"name":"","range":"0,6 MPa to 2 MPa","cmc":"1 · 10⁻⁴ · p + 1 Pa"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n-0,1 MPa do -0,09 MPa CMC 3 · 10⁻⁴ · p + 255 Pa\n-0,09 MPa do -0,015 MPa CMC 16 Pa\n-0,015 MPa do -0,009 MPa CMC 1 · 10⁻⁴ · p + 0,01 Pa\n-0,009 MPa do 0,009 MPa CMC 0,9 Pa\n0,009 MPa do 0,015 MPa CMC 1 · 10⁻⁴ · p + 0,01 Pa\n0,015 MPa do 0,1 MPa CMC 16 Pa\n0,1 MPa do 0,6 MPa CMC 60,3 Pa\n0,6 MPa do 2 MPa CMC 1 · 10⁻⁴ · p + 1 Pa\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP w oparciu o EURAMET cg-17 v.4.1","norm_bases":["C /I 1/ MAP","C /I 2/ MAP","C /I 3/ MAP","EURAMET cg-17 v.4.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":"p – wielkość mierzona (Pa)","note_en":"p – measured value (Pa)","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia\n- ciśnienie względne: podciśnienie i nadciśnienie (czynnik gaz) Wzorcowanie — Ciśnienie\nZakres:\n-0,1 MPa do -0,09 MPa CMC 3 · 10⁻⁴ · p + 255 Pa\n-0,09 MPa do -0,015 MPa CMC 16 Pa\n-0,015 MPa do -0,009 MPa CMC 1 · 10⁻⁴ · p + 0,01 Pa\n-0,009 MPa do 0,009 MPa CMC 0,9 Pa\n0,009 MPa do 0,015 MPa CMC 1 · 10⁻⁴ · p + 0,01 Pa\n0,015 MPa do 0,1 MPa CMC 16 Pa\n0,1 MPa do 0,6 MPa CMC 60,3 Pa\n0,6 MPa do 2 MPa CMC 1 · 10⁻⁴ · p + 1 Pa\nProcedura wewnętrzna; W stałej lokalizacji (S) C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP w oparciu o EURAMET cg-17 v.4.1 Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\nPrzetworniki cisnienia\n- cisnienie wzgledne: podcisnienie i nadcisnienie (czynnik gaz) Wzorcowanie — Cisnienie\nZakres:\n-0,1 MPa do -0,09 MPa CMC 3 · 10⁻⁴ · p + 255 Pa\n-0,09 MPa do -0,015 MPa CMC 16 Pa\n-0,015 MPa do -0,009 MPa CMC 1 · 10⁻⁴ · p + 0,01 Pa\n-0,009 MPa do 0,009 MPa CMC 0,9 Pa\n0,009 MPa do 0,015 MPa CMC 1 · 10⁻⁴ · p + 0,01 Pa\n0,015 MPa do 0,1 MPa CMC 16 Pa\n0,1 MPa do 0,6 MPa CMC 60,3 Pa\n0,6 MPa do 2 MPa CMC 1 · 10⁻⁴ · p + 1 Pa\nProcedura wewnetrzna; W stalej lokalizacji (S) C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP w oparciu o EURAMET cg-17 v.4.1","search_en":"Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters - gauge pressure: negative and positive pressure (gas medium) Calibration — Pressure Internal procedure; At permanent location (S) Pressure Internal procedure At permanent location (S) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP based on EURAMET cg-17 v.4.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":34,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP based on EURAMET cg-17 v.4.1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"-0,1 MPa to -0,09 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-0,09 MPa to -0,015 MPa","cmc":"16 Pa"},{"name":"","range":"-0,015 MPa to -0,009 MPa","cmc":"1 · 10⁻⁴ · p + 0,01 Pa"},{"name":"","range":"-0,009 MPa to 0,009 MPa","cmc":"0,9 Pa"},{"name":"","range":"0,009 MPa to 0,015 MPa","cmc":"1 · 10⁻⁴ · p + 0,01 Pa"},{"name":"","range":"0,015 MPa to 0,1 MPa","cmc":"16 Pa"},{"name":"","range":"0,1 MPa to 0,6 MPa","cmc":"60,3 Pa"},{"name":"","range":"0,6 MPa to 2 MPa","cmc":"1 · 10⁻⁴ · p + 1 Pa"}],"reference_de":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP auf Grundlage von EURAMET cg-17 v.4.1","regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte Druckmessumformer - Relativdruck: Unter- und Überdruck (Medium Gas) Kalibrierung — Druck Internes Verfahren; Am festen Standort (S) Druck Internes Verfahren Am festen Standort (S) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP auf Grundlage von EURAMET cg-17 v.4.1","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\nDruckmessumformer\n- Relativdruck: Unter- und Überdruck (Medium Gas)","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"-0,1 MPa to -0,09 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-0,09 MPa to -0,015 MPa","cmc":"16 Pa"},{"name":"","range":"-0,015 MPa to -0,009 MPa","cmc":"1 · 10⁻⁴ · p + 0,01 Pa"},{"name":"","range":"-0,009 MPa to 0,009 MPa","cmc":"0,9 Pa"},{"name":"","range":"0,009 MPa to 0,015 MPa","cmc":"1 · 10⁻⁴ · p + 0,01 Pa"},{"name":"","range":"0,015 MPa to 0,1 MPa","cmc":"16 Pa"},{"name":"","range":"0,1 MPa to 0,6 MPa","cmc":"60,3 Pa"},{"name":"","range":"0,6 MPa to 2 MPa","cmc":"1 · 10⁻⁴ · p + 1 Pa"}],"reference_zh":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP 依据EURAMET cg-17 v.4.1","regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 压力变送器 - 表压：负压和正压（介质为气体） 校准 — 压力 内部程序；在固定地点 (S) 压力 内部程序 在固定地点 (S) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP 依据EURAMET cg-17 v.4.1","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"弹簧管压力表\n电子压力计\n压力变送器\n- 表压：负压和正压（介质为气体）","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"-0,1 MPa to -0,09 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-0,09 MPa to -0,015 MPa","cmc":"16 Pa"},{"name":"","range":"-0,015 MPa to -0,009 MPa","cmc":"1 · 10⁻⁴ · p + 0,01 Pa"},{"name":"","range":"-0,009 MPa to 0,009 MPa","cmc":"0,9 Pa"},{"name":"","range":"0,009 MPa to 0,015 MPa","cmc":"1 · 10⁻⁴ · p + 0,01 Pa"},{"name":"","range":"0,015 MPa to 0,1 MPa","cmc":"16 Pa"},{"name":"","range":"0,1 MPa to 0,6 MPa","cmc":"60,3 Pa"},{"name":"","range":"0,6 MPa to 2 MPa","cmc":"1 · 10⁻⁴ · p + 1 Pa"}],"reference_cs":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP na základě EURAMET cg-17 v.4.1","regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry Převodníky tlaku - relativní tlak: podtlak a přetlak (médium plyn) Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) Tlak Vnitřní postup Ve stálé lokalitě (S) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP na základě EURAMET cg-17 v.4.1","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\nPřevodníky tlaku\n- relativní tlak: podtlak a přetlak (médium plyn)"},{"_id":"a257495b86289b2906f3de7c","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia\n- ciśnienie absolutne (czynnik gaz)","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\nPressure transmitters\n- absolute pressure (gas medium)","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"25 hPa do 100 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"},{"name":"","range":"100 hPa do 600 hPa","cmc":"17,3 Pa"},{"name":"","range":"600 hPa do 2000 hPa","cmc":"6 · 10⁻⁵ · p + 14 Pa"},{"name":"","range":"2000 hPa do 6000 hPa","cmc":"63,5 Pa"},{"name":"","range":"6000 hPa do 20000 hPa","cmc":"1 · 10⁻⁴ · p + 4 Pa"},{"name":"","range":"20000 hPa do 21000 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"}],"parameters_en":[{"name":"","range":"25 hPa to 100 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"},{"name":"","range":"100 hPa to 600 hPa","cmc":"17,3 Pa"},{"name":"","range":"600 hPa to 2000 hPa","cmc":"6 · 10⁻⁵ · p + 14 Pa"},{"name":"","range":"2000 hPa to 6000 hPa","cmc":"63,5 Pa"},{"name":"","range":"6000 hPa to 20000 hPa","cmc":"1 · 10⁻⁴ · p + 4 Pa"},{"name":"","range":"20000 hPa to 21000 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n25 hPa do 100 hPa CMC 3 · 10⁻⁴ · p + 270 Pa\n100 hPa do 600 hPa CMC 17,3 Pa\n600 hPa do 2000 hPa CMC 6 · 10⁻⁵ · p + 14 Pa\n2000 hPa do 6000 hPa CMC 63,5 Pa\n6000 hPa do 20000 hPa CMC 1 · 10⁻⁴ · p + 4 Pa\n20000 hPa do 21000 hPa CMC 3 · 10⁻⁴ · p + 270 Pa\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP w oparciu o EURAMET cg-17 v.4.1","norm_bases":["C /I 1/ MAP","C /I 2/ MAP","C /I 3/ MAP","EURAMET cg-17 v.4.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":"p – wielkość mierzona (Pa)","note_en":"p – measured value (Pa)","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia\n- ciśnienie absolutne (czynnik gaz) Wzorcowanie — Ciśnienie\nZakres:\n25 hPa do 100 hPa CMC 3 · 10⁻⁴ · p + 270 Pa\n100 hPa do 600 hPa CMC 17,3 Pa\n600 hPa do 2000 hPa CMC 6 · 10⁻⁵ · p + 14 Pa\n2000 hPa do 6000 hPa CMC 63,5 Pa\n6000 hPa do 20000 hPa CMC 1 · 10⁻⁴ · p + 4 Pa\n20000 hPa do 21000 hPa CMC 3 · 10⁻⁴ · p + 270 Pa\nProcedura wewnętrzna; W stałej lokalizacji (S) C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP w oparciu o EURAMET cg-17 v.4.1 Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\nPrzetworniki cisnienia\n- cisnienie absolutne (czynnik gaz) Wzorcowanie — Cisnienie\nZakres:\n25 hPa do 100 hPa CMC 3 · 10⁻⁴ · p + 270 Pa\n100 hPa do 600 hPa CMC 17,3 Pa\n600 hPa do 2000 hPa CMC 6 · 10⁻⁵ · p + 14 Pa\n2000 hPa do 6000 hPa CMC 63,5 Pa\n6000 hPa do 20000 hPa CMC 1 · 10⁻⁴ · p + 4 Pa\n20000 hPa do 21000 hPa CMC 3 · 10⁻⁴ · p + 270 Pa\nProcedura wewnetrzna; W stalej lokalizacji (S) C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP w oparciu o EURAMET cg-17 v.4.1","search_en":"Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters - absolute pressure (gas medium) Calibration — Pressure Internal procedure; At permanent location (S) Pressure Internal procedure At permanent location (S) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP based on EURAMET cg-17 v.4.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":35,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP based on EURAMET cg-17 v.4.1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"25 hPa to 100 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"},{"name":"","range":"100 hPa to 600 hPa","cmc":"17,3 Pa"},{"name":"","range":"600 hPa to 2000 hPa","cmc":"6 · 10⁻⁵ · p + 14 Pa"},{"name":"","range":"2000 hPa to 6000 hPa","cmc":"63,5 Pa"},{"name":"","range":"6000 hPa to 20000 hPa","cmc":"1 · 10⁻⁴ · p + 4 Pa"},{"name":"","range":"20000 hPa to 21000 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"}],"reference_de":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP auf Grundlage von EURAMET cg-17 v.4.1","regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte Druckmessumformer - Absolutdruck (Medium Gas) Kalibrierung — Druck Internes Verfahren; Am festen Standort (S) Druck Internes Verfahren Am festen Standort (S) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP auf Grundlage von EURAMET cg-17 v.4.1","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\nDruckmessumformer\n- Absolutdruck (Medium Gas)","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"25 hPa to 100 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"},{"name":"","range":"100 hPa to 600 hPa","cmc":"17,3 Pa"},{"name":"","range":"600 hPa to 2000 hPa","cmc":"6 · 10⁻⁵ · p + 14 Pa"},{"name":"","range":"2000 hPa to 6000 hPa","cmc":"63,5 Pa"},{"name":"","range":"6000 hPa to 20000 hPa","cmc":"1 · 10⁻⁴ · p + 4 Pa"},{"name":"","range":"20000 hPa to 21000 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"}],"reference_zh":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP 依据EURAMET cg-17 v.4.1","regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 压力变送器 - 绝对压力（介质为气体） 校准 — 压力 内部程序；在固定地点 (S) 压力 内部程序 在固定地点 (S) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP 依据EURAMET cg-17 v.4.1","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"弹簧管压力表\n电子压力计\n压力变送器\n- 绝对压力（介质为气体）","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"25 hPa to 100 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"},{"name":"","range":"100 hPa to 600 hPa","cmc":"17,3 Pa"},{"name":"","range":"600 hPa to 2000 hPa","cmc":"6 · 10⁻⁵ · p + 14 Pa"},{"name":"","range":"2000 hPa to 6000 hPa","cmc":"63,5 Pa"},{"name":"","range":"6000 hPa to 20000 hPa","cmc":"1 · 10⁻⁴ · p + 4 Pa"},{"name":"","range":"20000 hPa to 21000 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"}],"reference_cs":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP na základě EURAMET cg-17 v.4.1","regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry Převodníky tlaku - absolutní tlak (médium plyn) Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) Tlak Vnitřní postup Ve stálé lokalitě (S) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP na základě EURAMET cg-17 v.4.1","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\nPřevodníky tlaku\n- absolutní tlak (médium plyn)"},{"_id":"4d34c273ea130924afd76391","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia\n- ciśnienie względne: podciśnienie i nad ciśnienie (czynnik gaz)","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\nPressure transmitters\n- gauge pressure: negative and positive pressure (gas medium)","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"-0,1 MPa do -0,04 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-0,04 MPa do 0,04 MPa","cmc":"4 · 10⁻⁴ · p + 22,4 Pa"},{"name":"","range":"0,04 MPa do 2 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-2500 Pa do 2500 Pa","cmc":"1,3 Pa"}],"parameters_en":[{"name":"","range":"-0,1 MPa to -0,04 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-0,04 MPa to 0,04 MPa","cmc":"4 · 10⁻⁴ · p + 22,4 Pa"},{"name":"","range":"0,04 MPa to 2 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-2500 Pa to 2500 Pa","cmc":"1,3 Pa"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n-0,1 MPa do -0,04 MPa CMC 3 · 10⁻⁴ · p + 255 Pa\n-0,04 MPa do 0,04 MPa CMC 4 · 10⁻⁴ · p + 22,4 Pa\n0,04 MPa do 2 MPa CMC 3 · 10⁻⁴ · p + 255 Pa\n-2500 Pa do 2500 Pa CMC 1,3 Pa\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP\nP4 / MAP","norm_bases":["C /I 1/ MAP","C /I 2/ MAP","C /I 3/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"P","note":"p – wielkość mierzona (Pa)","note_en":"p – measured value (Pa)","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia\n- ciśnienie względne: podciśnienie i nad ciśnienie (czynnik gaz) Wzorcowanie — Ciśnienie\nZakres:\n-0,1 MPa do -0,04 MPa CMC 3 · 10⁻⁴ · p + 255 Pa\n-0,04 MPa do 0,04 MPa CMC 4 · 10⁻⁴ · p + 22,4 Pa\n0,04 MPa do 2 MPa CMC 3 · 10⁻⁴ · p + 255 Pa\n-2500 Pa do 2500 Pa CMC 1,3 Pa\nProcedura wewnętrzna; Poza stałą lokalizacją (P) C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP\nP4 / MAP Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\nPrzetworniki cisnienia\n- cisnienie wzgledne: podcisnienie i nad cisnienie (czynnik gaz) Wzorcowanie — Cisnienie\nZakres:\n-0,1 MPa do -0,04 MPa CMC 3 · 10⁻⁴ · p + 255 Pa\n-0,04 MPa do 0,04 MPa CMC 4 · 10⁻⁴ · p + 22,4 Pa\n0,04 MPa do 2 MPa CMC 3 · 10⁻⁴ · p + 255 Pa\n-2500 Pa do 2500 Pa CMC 1,3 Pa\nProcedura wewnetrzna; Poza stala lokalizacja (P) C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP\nP4 / MAP","search_en":"Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters - gauge pressure: negative and positive pressure (gas medium) Calibration — Pressure Internal procedure; Outside of permanent location (P) Pressure Internal procedure Outside of permanent location (P) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":36,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"-0,1 MPa to -0,04 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-0,04 MPa to 0,04 MPa","cmc":"4 · 10⁻⁴ · p + 22,4 Pa"},{"name":"","range":"0,04 MPa to 2 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-2500 Pa to 2500 Pa","cmc":"1,3 Pa"}],"regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte Druckmessumformer - Relativdruck: Unter- und Überdruck (Medium Gas) Kalibrierung — Druck Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Druck Internes Verfahren Außerhalb des festen Standorts (P) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\nDruckmessumformer\n- Relativdruck: Unter- und Überdruck (Medium Gas)","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"-0,1 MPa to -0,04 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-0,04 MPa to 0,04 MPa","cmc":"4 · 10⁻⁴ · p + 22,4 Pa"},{"name":"","range":"0,04 MPa to 2 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-2500 Pa to 2500 Pa","cmc":"1,3 Pa"}],"regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 压力变送器 - 表压：负压和正压（介质为气体） 校准 — 压力 内部程序；固定地点以外 (P) 压力 内部程序 固定地点以外 (P) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"弹簧管压力表\n电子压力计\n压力变送器\n- 表压：负压和正压（介质为气体）","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"-0,1 MPa to -0,04 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-0,04 MPa to 0,04 MPa","cmc":"4 · 10⁻⁴ · p + 22,4 Pa"},{"name":"","range":"0,04 MPa to 2 MPa","cmc":"3 · 10⁻⁴ · p + 255 Pa"},{"name":"","range":"-2500 Pa to 2500 Pa","cmc":"1,3 Pa"}],"regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry Převodníky tlaku - relativní tlak: podtlak a přetlak (médium plyn) Kalibrace — Tlak Vnitřní postup; Mimo stálé pracoviště (P) Tlak Vnitřní postup Mimo stálou lokalitu (P) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\nPřevodníky tlaku\n- relativní tlak: podtlak a přetlak (médium plyn)"},{"_id":"005a8f32bc32a5194e03f06e","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia\n- ciśnienie absolutne (czynnik gaz)","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\nPressure transmitters\n- absolute pressure (gas medium)","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"25 hPa do 600 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"},{"name":"","range":"600 hPa do 800 hPa","cmc":"70 Pa"},{"name":"","range":"800 hPa do 1200 hPa","cmc":"60 Pa"},{"name":"","range":"1200 hPa do 1400 hPa","cmc":"70 Pa"},{"name":"","range":"1400 hPa do 21000 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"}],"parameters_en":[{"name":"","range":"25 hPa to 600 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"},{"name":"","range":"600 hPa to 800 hPa","cmc":"70 Pa"},{"name":"","range":"800 hPa to 1200 hPa","cmc":"60 Pa"},{"name":"","range":"1200 hPa to 1400 hPa","cmc":"70 Pa"},{"name":"","range":"1400 hPa to 21000 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n25 hPa do 600 hPa CMC 3 · 10⁻⁴ · p + 270 Pa\n600 hPa do 800 hPa CMC 70 Pa\n800 hPa do 1200 hPa CMC 60 Pa\n1200 hPa do 1400 hPa CMC 70 Pa\n1400 hPa do 21000 hPa CMC 3 · 10⁻⁴ · p + 270 Pa\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP\nP4 / MAP","norm_bases":["C /I 1/ MAP","C /I 2/ MAP","C /I 3/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"P","note":"p – wielkość mierzona (Pa)","note_en":"p – measured value (Pa)","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia\n- ciśnienie absolutne (czynnik gaz) Wzorcowanie — Ciśnienie\nZakres:\n25 hPa do 600 hPa CMC 3 · 10⁻⁴ · p + 270 Pa\n600 hPa do 800 hPa CMC 70 Pa\n800 hPa do 1200 hPa CMC 60 Pa\n1200 hPa do 1400 hPa CMC 70 Pa\n1400 hPa do 21000 hPa CMC 3 · 10⁻⁴ · p + 270 Pa\nProcedura wewnętrzna; Poza stałą lokalizacją (P) C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP\nP4 / MAP Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\nPrzetworniki cisnienia\n- cisnienie absolutne (czynnik gaz) Wzorcowanie — Cisnienie\nZakres:\n25 hPa do 600 hPa CMC 3 · 10⁻⁴ · p + 270 Pa\n600 hPa do 800 hPa CMC 70 Pa\n800 hPa do 1200 hPa CMC 60 Pa\n1200 hPa do 1400 hPa CMC 70 Pa\n1400 hPa do 21000 hPa CMC 3 · 10⁻⁴ · p + 270 Pa\nProcedura wewnetrzna; Poza stala lokalizacja (P) C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP\nP4 / MAP","search_en":"Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters - absolute pressure (gas medium) Calibration — Pressure Internal procedure; Outside of permanent location (P) Pressure Internal procedure Outside of permanent location (P) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":37,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"25 hPa to 600 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"},{"name":"","range":"600 hPa to 800 hPa","cmc":"70 Pa"},{"name":"","range":"800 hPa to 1200 hPa","cmc":"60 Pa"},{"name":"","range":"1200 hPa to 1400 hPa","cmc":"70 Pa"},{"name":"","range":"1400 hPa to 21000 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"}],"regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte Druckmessumformer - Absolutdruck (Medium Gas) Kalibrierung — Druck Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Druck Internes Verfahren Außerhalb des festen Standorts (P) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\nDruckmessumformer\n- Absolutdruck (Medium Gas)","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"25 hPa to 600 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"},{"name":"","range":"600 hPa to 800 hPa","cmc":"70 Pa"},{"name":"","range":"800 hPa to 1200 hPa","cmc":"60 Pa"},{"name":"","range":"1200 hPa to 1400 hPa","cmc":"70 Pa"},{"name":"","range":"1400 hPa to 21000 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"}],"regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 压力变送器 - 绝对压力（介质为气体） 校准 — 压力 内部程序；固定地点以外 (P) 压力 内部程序 固定地点以外 (P) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"弹簧管压力表\n电子压力计\n压力变送器\n- 绝对压力（介质为气体）","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"25 hPa to 600 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"},{"name":"","range":"600 hPa to 800 hPa","cmc":"70 Pa"},{"name":"","range":"800 hPa to 1200 hPa","cmc":"60 Pa"},{"name":"","range":"1200 hPa to 1400 hPa","cmc":"70 Pa"},{"name":"","range":"1400 hPa to 21000 hPa","cmc":"3 · 10⁻⁴ · p + 270 Pa"}],"regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry Převodníky tlaku - absolutní tlak (médium plyn) Kalibrace — Tlak Vnitřní postup; Mimo stálé pracoviště (P) Tlak Vnitřní postup Mimo stálou lokalitu (P) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\nPřevodníky tlaku\n- absolutní tlak (médium plyn)"},{"_id":"9931cb0e2c110b23b7b241ca","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia\n- ciśnienie względne: nadciśnienie (olej)","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\nPressure transmitters\n- gauge pressure: positive pressure (oil)","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"0,02 MPa do 0,06 MPa","cmc":"25 Pa"},{"name":"","range":"0,06 MPa do 0,6 MPa","cmc":"4 · 10⁻⁴ · p + 46 Pa"},{"name":"","range":"0,6 MPa do 6 MPa","cmc":"18 · 10⁻⁵ · p + 550 Pa"},{"name":"","range":"6 MPa do 25 MPa","cmc":"4 · 10⁻⁴ · p + 4500 Pa"},{"name":"","range":"25 MPa do 60 MPa","cmc":"4 · 10⁻⁴ · p + 7000 Pa"}],"parameters_en":[{"name":"","range":"0,02 MPa do 0,06 MPa","cmc":"25 Pa"},{"name":"","range":"0,06 MPa do 0,6 MPa","cmc":"4 · 10⁻⁴ · p + 46 Pa"},{"name":"","range":"0,6 MPa to 6 MPa","cmc":"18 · 10⁻⁵ · p + 550 Pa"},{"name":"","range":"6 MPa to 25 MPa","cmc":"4 · 10⁻⁴ · p + 4500 Pa"},{"name":"","range":"25 MPa do 60 MPa","cmc":"4 · 10⁻⁴ · p + 7000 Pa"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n0,02 MPa do 0,06 MPa CMC 25 Pa\n0,06 MPa do 0,6 MPa CMC 4 · 10⁻⁴ · p + 46 Pa\n0,6 MPa do 6 MPa CMC 18 · 10⁻⁵ · p + 550 Pa\n6 MPa do 25 MPa CMC 4 · 10⁻⁴ · p + 4500 Pa\n25 MPa do 60 MPa CMC 4 · 10⁻⁴ · p + 7000 Pa\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP","norm_bases":["C /I 1/ MAP","C /I 2/ MAP","C /I 3/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":"p – wielkość mierzona (Pa)","note_en":"p – measured value (Pa)","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia\n- ciśnienie względne: nadciśnienie (olej) Wzorcowanie — Ciśnienie\nZakres:\n0,02 MPa do 0,06 MPa CMC 25 Pa\n0,06 MPa do 0,6 MPa CMC 4 · 10⁻⁴ · p + 46 Pa\n0,6 MPa do 6 MPa CMC 18 · 10⁻⁵ · p + 550 Pa\n6 MPa do 25 MPa CMC 4 · 10⁻⁴ · p + 4500 Pa\n25 MPa do 60 MPa CMC 4 · 10⁻⁴ · p + 7000 Pa\nProcedura wewnętrzna; W stałej lokalizacji (S) C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\nPrzetworniki cisnienia\n- cisnienie wzgledne: nadcisnienie (olej) Wzorcowanie — Cisnienie\nZakres:\n0,02 MPa do 0,06 MPa CMC 25 Pa\n0,06 MPa do 0,6 MPa CMC 4 · 10⁻⁴ · p + 46 Pa\n0,6 MPa do 6 MPa CMC 18 · 10⁻⁵ · p + 550 Pa\n6 MPa do 25 MPa CMC 4 · 10⁻⁴ · p + 4500 Pa\n25 MPa do 60 MPa CMC 4 · 10⁻⁴ · p + 7000 Pa\nProcedura wewnetrzna; W stalej lokalizacji (S) C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP","search_en":"Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters - gauge pressure: positive pressure (oil) Calibration — Pressure Internal procedure; At permanent location (S) Pressure Internal procedure At permanent location (S) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":38,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"0,02 MPa do 0,06 MPa","cmc":"25 Pa"},{"name":"","range":"0,06 MPa do 0,6 MPa","cmc":"4 · 10⁻⁴ · p + 46 Pa"},{"name":"","range":"0,6 MPa bis 6 MPa","cmc":"18 · 10⁻⁵ · p + 550 Pa"},{"name":"","range":"6 MPa bis 25 MPa","cmc":"4 · 10⁻⁴ · p + 4500 Pa"},{"name":"","range":"25 MPa do 60 MPa","cmc":"4 · 10⁻⁴ · p + 7000 Pa"}],"regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte Druckmessumformer - Relativdruck: Überdruck (Öl) Kalibrierung — Druck Internes Verfahren; Am festen Standort (S) Druck Internes Verfahren Am festen Standort (S) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\nDruckmessumformer\n- Relativdruck: Überdruck (Öl)","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"0,02 MPa do 0,06 MPa","cmc":"25 Pa"},{"name":"","range":"0,06 MPa do 0,6 MPa","cmc":"4 · 10⁻⁴ · p + 46 Pa"},{"name":"","range":"0,6 MPa 至 6 MPa","cmc":"18 · 10⁻⁵ · p + 550 Pa"},{"name":"","range":"6 MPa 至 25 MPa","cmc":"4 · 10⁻⁴ · p + 4500 Pa"},{"name":"","range":"25 MPa do 60 MPa","cmc":"4 · 10⁻⁴ · p + 7000 Pa"}],"regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 压力变送器 - 表压：正压（油） 校准 — 压力 内部程序；在固定地点 (S) 压力 内部程序 在固定地点 (S) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"弹簧管压力表\n电子压力计\n压力变送器\n- 表压：正压（油）","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"0,02 MPa do 0,06 MPa","cmc":"25 Pa"},{"name":"","range":"0,06 MPa do 0,6 MPa","cmc":"4 · 10⁻⁴ · p + 46 Pa"},{"name":"","range":"0,6 MPa do 6 MPa","cmc":"18 · 10⁻⁵ · p + 550 Pa"},{"name":"","range":"6 MPa do 25 MPa","cmc":"4 · 10⁻⁴ · p + 4500 Pa"},{"name":"","range":"25 MPa do 60 MPa","cmc":"4 · 10⁻⁴ · p + 7000 Pa"}],"regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry Převodníky tlaku - relativní tlak: přetlak (olej) Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) Tlak Vnitřní postup Ve stálé lokalitě (S) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\nPřevodníky tlaku\n- relativní tlak: přetlak (olej)"},{"_id":"30d3a5286bc1c6bce1a492f9","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia\n- ciśnienie względne: nadciśnienie (olej)","test_object_en":"Bourdon tube pressure gauges\nElectronic pressure gauges\nPressure transmitters\n- gauge pressure: positive pressure (oil)","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"0 MPa do 6 MPa","cmc":"7000 Pa"},{"name":"","range":"6 MPa do 20 MPa","cmc":"4 · 10⁻⁴ · p + 7000 Pa"}],"parameters_en":[{"name":"","range":"0 MPa to 6 MPa","cmc":"7000 Pa"},{"name":"","range":"6 MPa to 20 MPa","cmc":"4 · 10⁻⁴ · p + 7000 Pa"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n0 MPa do 6 MPa CMC 7000 Pa\n6 MPa do 20 MPa CMC 4 · 10⁻⁴ · p + 7000 Pa\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP\nP4 / MAP","norm_bases":["C /I 1/ MAP","C /I 2/ MAP","C /I 3/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"P","note":"p – wielkość mierzona (Pa)","note_en":"p – measured value (Pa)","search_text":"Ciśnieniomierze sprężynowe\nCiśnieniomierze elektroniczne\nPrzetworniki ciśnienia\n- ciśnienie względne: nadciśnienie (olej) Wzorcowanie — Ciśnienie\nZakres:\n0 MPa do 6 MPa CMC 7000 Pa\n6 MPa do 20 MPa CMC 4 · 10⁻⁴ · p + 7000 Pa\nProcedura wewnętrzna; Poza stałą lokalizacją (P) C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP\nP4 / MAP Cisnieniomierze sprezynowe\nCisnieniomierze elektroniczne\nPrzetworniki cisnienia\n- cisnienie wzgledne: nadcisnienie (olej) Wzorcowanie — Cisnienie\nZakres:\n0 MPa do 6 MPa CMC 7000 Pa\n6 MPa do 20 MPa CMC 4 · 10⁻⁴ · p + 7000 Pa\nProcedura wewnetrzna; Poza stala lokalizacja (P) C /I 1/ MAP\nC /I 2/ MAP\nC /I 3/ MAP\nP4 / MAP","search_en":"Bourdon tube pressure gauges Electronic pressure gauges Pressure transmitters - gauge pressure: positive pressure (oil) Calibration — Pressure Internal procedure; Outside of permanent location (P) Pressure Internal procedure Outside of permanent location (P) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":39,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"0 MPa to 6 MPa","cmc":"7000 Pa"},{"name":"","range":"6 MPa to 20 MPa","cmc":"4 · 10⁻⁴ · p + 7000 Pa"}],"regulatory_area_de":"Druck","search_de":"Federmanometer Elektronische Druckmessgeräte Druckmessumformer - Relativdruck: Überdruck (Öl) Kalibrierung — Druck Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Druck Internes Verfahren Außerhalb des festen Standorts (P) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Federmanometer\nElektronische Druckmessgeräte\nDruckmessumformer\n- Relativdruck: Überdruck (Öl)","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"0 MPa to 6 MPa","cmc":"7000 Pa"},{"name":"","range":"6 MPa to 20 MPa","cmc":"4 · 10⁻⁴ · p + 7000 Pa"}],"regulatory_area_zh":"压力","search_zh":"弹簧管压力表 电子压力计 压力变送器 - 表压：正压（油） 校准 — 压力 内部程序；固定地点以外 (P) 压力 内部程序 固定地点以外 (P) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"弹簧管压力表\n电子压力计\n压力变送器\n- 表压：正压（油）","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"0 MPa to 6 MPa","cmc":"7000 Pa"},{"name":"","range":"6 MPa to 20 MPa","cmc":"4 · 10⁻⁴ · p + 7000 Pa"}],"regulatory_area_cs":"Tlak","search_cs":"Deformační tlakoměry Elektronické tlakoměry Převodníky tlaku - relativní tlak: přetlak (olej) Kalibrace — Tlak Vnitřní postup; Mimo stálé pracoviště (P) Tlak Vnitřní postup Mimo stálou lokalitu (P) C /I 1/ MAP C /I 2/ MAP C /I 3/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Deformační tlakoměry\nElektronické tlakoměry\nPřevodníky tlaku\n- relativní tlak: přetlak (olej)"},{"_id":"2b49284695726e0aa0ace89a","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych","test_object_en":"Noble metal thermocouples\nBase metal thermocouples","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do 250 °C","cmc":"0,35 °C"},{"name":"","range":"250 °C do 1085 °C","cmc":"0,6 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"0,8 °C"},{"name":"","range":"1200 °C do 1300 °C","cmc":"1,3 °C"},{"name":"","range":"1300 °C do 1450 °C","cmc":"1,8 °C"}],"parameters_en":[{"name":"","range":"-80 °C do 250 °C","cmc":"0,35 °C"},{"name":"","range":"250 °C do 1085 °C","cmc":"0,6 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"0,8 °C"},{"name":"","range":"1200 °C to 1300 °C","cmc":"1,3 °C"},{"name":"","range":"1300 °C do 1450 °C","cmc":"1,8 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do 250 °C CMC 0,35 °C\n250 °C do 1085 °C CMC 0,6 °C\n1085 °C do 1200 °C CMC 0,8 °C\n1200 °C do 1300 °C CMC 1,3 °C\n1300 °C do 1450 °C CMC 1,8 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"T /I 1/ MAP w oparciu o EURAMET cg-8 v. 3.1","norm_bases":["T /I 1/ MAP","EURAMET cg-8 v. 3.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do 250 °C CMC 0,35 °C\n250 °C do 1085 °C CMC 0,6 °C\n1085 °C do 1200 °C CMC 0,8 °C\n1200 °C do 1300 °C CMC 1,3 °C\n1300 °C do 1450 °C CMC 1,8 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) T /I 1/ MAP w oparciu o EURAMET cg-8 v. 3.1 Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do 250 °C CMC 0,35 °C\n250 °C do 1085 °C CMC 0,6 °C\n1085 °C do 1200 °C CMC 0,8 °C\n1200 °C do 1300 °C CMC 1,3 °C\n1300 °C do 1450 °C CMC 1,8 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) T /I 1/ MAP w oparciu o EURAMET cg-8 v. 3.1","search_en":"Noble metal thermocouples Base metal thermocouples Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) T /I 1/ MAP based on EURAMET cg-8 v. 3.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":40,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"T /I 1/ MAP based on EURAMET cg-8 v. 3.1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C do 250 °C","cmc":"0,35 °C"},{"name":"","range":"250 °C do 1085 °C","cmc":"0,6 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"0,8 °C"},{"name":"","range":"1200 °C bis 1300 °C","cmc":"1,3 °C"},{"name":"","range":"1300 °C do 1450 °C","cmc":"1,8 °C"}],"reference_de":"T /I 1/ MAP auf Grundlage von EURAMET cg-8 v. 3.1","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Edelmetall-Thermoelemente Thermoelemente aus unedlen Metallen Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) T /I 1/ MAP auf Grundlage von EURAMET cg-8 v. 3.1","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Edelmetall-Thermoelemente\nThermoelemente aus unedlen Metallen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C do 250 °C","cmc":"0,35 °C"},{"name":"","range":"250 °C do 1085 °C","cmc":"0,6 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"0,8 °C"},{"name":"","range":"1200 °C 至 1300 °C","cmc":"1,3 °C"},{"name":"","range":"1300 °C do 1450 °C","cmc":"1,8 °C"}],"reference_zh":"T /I 1/ MAP 依据EURAMET cg-8 v. 3.1","regulatory_area_zh":"温度（电测温）","search_zh":"贵金属热电偶 贱金属热电偶传感器 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 温度（电测温） 内部程序 直接法 在固定地点 (S) T /I 1/ MAP 依据EURAMET cg-8 v. 3.1","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"贵金属热电偶\n贱金属热电偶传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C do 250 °C","cmc":"0,35 °C"},{"name":"","range":"250 °C do 1085 °C","cmc":"0,6 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"0,8 °C"},{"name":"","range":"1200 °C do 1300 °C","cmc":"1,3 °C"},{"name":"","range":"1300 °C do 1450 °C","cmc":"1,8 °C"}],"reference_cs":"T /I 1/ MAP na základě EURAMET cg-8 v. 3.1","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Termoelektrické snímače z drahých kovů Termoelektrické snímače z obecných kovů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) T /I 1/ MAP na základě EURAMET cg-8 v. 3.1","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Termoelektrické snímače z drahých kovů\nTermoelektrické snímače z obecných kovů"},{"_id":"afd19c0d5d17da0d43ca8246","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych","test_object_en":"Noble metal thermocouples\nBase metal thermocouples","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-30 °C do 110 °C","cmc":"0,5 °C"},{"name":"","range":"110 °C do 660 °C","cmc":"1,0 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 110 °C","cmc":"0,5 °C"},{"name":"","range":"110 °C to 660 °C","cmc":"1,0 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 110 °C CMC 0,5 °C\n110 °C do 660 °C CMC 1,0 °C\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"T /I 1/ MAP\nP4 / MAP","norm_bases":["T /I 1/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 110 °C CMC 0,5 °C\n110 °C do 660 °C CMC 1,0 °C\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) T /I 1/ MAP\nP4 / MAP Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 110 °C CMC 0,5 °C\n110 °C do 660 °C CMC 1,0 °C\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) T /I 1/ MAP\nP4 / MAP","search_en":"Noble metal thermocouples Base metal thermocouples Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Direct method Outside of permanent location (P) T /I 1/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":41,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-30 °C to 110 °C","cmc":"0,5 °C"},{"name":"","range":"110 °C to 660 °C","cmc":"1,0 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Edelmetall-Thermoelemente Thermoelemente aus unedlen Metallen Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) T /I 1/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Edelmetall-Thermoelemente\nThermoelemente aus unedlen Metallen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-30 °C to 110 °C","cmc":"0,5 °C"},{"name":"","range":"110 °C to 660 °C","cmc":"1,0 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"贵金属热电偶 贱金属热电偶传感器 校准 — 温度（电测温） 内部程序；直接法；固定地点以外 (P) 温度（电测温） 内部程序 直接法 固定地点以外 (P) T /I 1/ MAP P4 / MAP","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"贵金属热电偶\n贱金属热电偶传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-30 °C to 110 °C","cmc":"0,5 °C"},{"name":"","range":"110 °C to 660 °C","cmc":"1,0 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Termoelektrické snímače z drahých kovů Termoelektrické snímače z obecných kovů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) T /I 1/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Termoelektrické snímače z drahých kovů\nTermoelektrické snímače z obecných kovů"},{"_id":"c0a562b5003c441884224f07","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Czujniki termometrów rezystancyjnych","test_object_en":"Resistance thermometer sensors","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do -40 °C","cmc":"0,02 °C"},{"name":"","range":"-40 °C do 250 °C","cmc":"0,01 °C"},{"name":"","range":"250 °C do 660 °C","cmc":"0,12 °C"},{"name":"","range":"0,01 °C","cmc":"0,005 °C"}],"parameters_en":[{"name":"","range":"-80 °C to -40 °C","cmc":"0,02 °C"},{"name":"","range":"-40 °C to 250 °C","cmc":"0,01 °C"},{"name":"","range":"250 °C to 660 °C","cmc":"0,12 °C"},{"name":"","range":"0,01 °C","cmc":"0,005 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -40 °C CMC 0,02 °C\n-40 °C do 250 °C CMC 0,01 °C\n250 °C do 660 °C CMC 0,12 °C\n0,01 °C CMC 0,005 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"T /I 2/ MAP","norm_bases":["T /I 2/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki termometrów rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -40 °C CMC 0,02 °C\n-40 °C do 250 °C CMC 0,01 °C\n250 °C do 660 °C CMC 0,12 °C\n0,01 °C CMC 0,005 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) T /I 2/ MAP Czujniki termometrow rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -40 °C CMC 0,02 °C\n-40 °C do 250 °C CMC 0,01 °C\n250 °C do 660 °C CMC 0,12 °C\n0,01 °C CMC 0,005 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) T /I 2/ MAP","search_en":"Resistance thermometer sensors Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) T /I 2/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":42,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to -40 °C","cmc":"0,02 °C"},{"name":"","range":"-40 °C to 250 °C","cmc":"0,01 °C"},{"name":"","range":"250 °C to 660 °C","cmc":"0,12 °C"},{"name":"","range":"0,01 °C","cmc":"0,005 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Fühler von Widerstandsthermometern Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) T /I 2/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Fühler von Widerstandsthermometern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C to -40 °C","cmc":"0,02 °C"},{"name":"","range":"-40 °C to 250 °C","cmc":"0,01 °C"},{"name":"","range":"250 °C to 660 °C","cmc":"0,12 °C"},{"name":"","range":"0,01 °C","cmc":"0,005 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电阻温度计传感器 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 温度（电测温） 内部程序 直接法 在固定地点 (S) T /I 2/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"电阻温度计传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to -40 °C","cmc":"0,02 °C"},{"name":"","range":"-40 °C to 250 °C","cmc":"0,01 °C"},{"name":"","range":"250 °C to 660 °C","cmc":"0,12 °C"},{"name":"","range":"0,01 °C","cmc":"0,005 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Čidla odporových teploměrů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) T /I 2/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Čidla odporových teploměrů"},{"_id":"20c6ed296a54a9a616d53c63","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Czujniki termometrów rezystancyjnych","test_object_en":"Resistance thermometer sensors","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-30 °C do 110 °C","cmc":"0,03 °C"},{"name":"","range":"110 °C do 660 °C","cmc":"0,15 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 110 °C","cmc":"0,03 °C"},{"name":"","range":"110 °C to 660 °C","cmc":"0,15 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 110 °C CMC 0,03 °C\n110 °C do 660 °C CMC 0,15 °C\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"T /I 2/ MAP\nP4 / MAP","norm_bases":["T /I 2/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Czujniki termometrów rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 110 °C CMC 0,03 °C\n110 °C do 660 °C CMC 0,15 °C\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) T /I 2/ MAP\nP4 / MAP Czujniki termometrow rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 110 °C CMC 0,03 °C\n110 °C do 660 °C CMC 0,15 °C\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) T /I 2/ MAP\nP4 / MAP","search_en":"Resistance thermometer sensors Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Direct method Outside of permanent location (P) T /I 2/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":43,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-30 °C to 110 °C","cmc":"0,03 °C"},{"name":"","range":"110 °C to 660 °C","cmc":"0,15 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Fühler von Widerstandsthermometern Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) T /I 2/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Fühler von Widerstandsthermometern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-30 °C to 110 °C","cmc":"0,03 °C"},{"name":"","range":"110 °C to 660 °C","cmc":"0,15 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电阻温度计传感器 校准 — 温度（电测温） 内部程序；直接法；固定地点以外 (P) 温度（电测温） 内部程序 直接法 固定地点以外 (P) T /I 2/ MAP P4 / MAP","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"电阻温度计传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-30 °C to 110 °C","cmc":"0,03 °C"},{"name":"","range":"110 °C to 660 °C","cmc":"0,15 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Čidla odporových teploměrů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) T /I 2/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Čidla odporových teploměrů"},{"_id":"beb2a15578e0add6230682a8","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne\n(z rejestracją temperatury)\nPrzetworniki temperatury\n(zawierające czujniki temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers\n(with temperature recording)\nTemperature transmitters\n(containing temperature sensors)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do -40 °C","cmc":"0,02 °C"},{"name":"","range":"-40 °C do 250 °C","cmc":"0,01 °C"},{"name":"","range":"250 °C do 660 °C","cmc":"0,12 °C"},{"name":"","range":"660 °C do 1085 °C","cmc":"0,5 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"0,8 °C"},{"name":"","range":"1200 °C do 1300 °C","cmc":"1,3 °C"},{"name":"","range":"1300 °C do 1450 °C","cmc":"1,8 °C"},{"name":"","range":"0,01 °C","cmc":"0,005 °C"}],"parameters_en":[{"name":"","range":"-80 °C do -40 °C","cmc":"0,02 °C"},{"name":"","range":"-40 °C do 250 °C","cmc":"0,01 °C"},{"name":"","range":"250 °C do 660 °C","cmc":"0,12 °C"},{"name":"","range":"660 °C do 1085 °C","cmc":"0,5 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"0,8 °C"},{"name":"","range":"1200 °C to 1300 °C","cmc":"1,3 °C"},{"name":"","range":"1300 °C do 1450 °C","cmc":"1,8 °C"},{"name":"","range":"0,01 °C","cmc":"0,005 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -40 °C CMC 0,02 °C\n-40 °C do 250 °C CMC 0,01 °C\n250 °C do 660 °C CMC 0,12 °C\n660 °C do 1085 °C CMC 0,5 °C\n1085 °C do 1200 °C CMC 0,8 °C\n1200 °C do 1300 °C CMC 1,3 °C\n1300 °C do 1450 °C CMC 1,8 °C\n0,01 °C CMC 0,005 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"T /I 9/ MAP","norm_bases":["T /I 9/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne\n(z rejestracją temperatury)\nPrzetworniki temperatury\n(zawierające czujniki temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -40 °C CMC 0,02 °C\n-40 °C do 250 °C CMC 0,01 °C\n250 °C do 660 °C CMC 0,12 °C\n660 °C do 1085 °C CMC 0,5 °C\n1085 °C do 1200 °C CMC 0,8 °C\n1200 °C do 1300 °C CMC 1,3 °C\n1300 °C do 1450 °C CMC 1,8 °C\n0,01 °C CMC 0,005 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) T /I 9/ MAP Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne\n(z rejestracja temperatury)\nPrzetworniki temperatury\n(zawierajace czujniki temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -40 °C CMC 0,02 °C\n-40 °C do 250 °C CMC 0,01 °C\n250 °C do 660 °C CMC 0,12 °C\n660 °C do 1085 °C CMC 0,5 °C\n1085 °C do 1200 °C CMC 0,8 °C\n1200 °C do 1300 °C CMC 1,3 °C\n1300 °C do 1450 °C CMC 1,8 °C\n0,01 °C CMC 0,005 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) T /I 9/ MAP","search_en":"Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Temperature transmitters (containing temperature sensors) Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) T /I 9/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":44,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C do -40 °C","cmc":"0,02 °C"},{"name":"","range":"-40 °C do 250 °C","cmc":"0,01 °C"},{"name":"","range":"250 °C do 660 °C","cmc":"0,12 °C"},{"name":"","range":"660 °C do 1085 °C","cmc":"0,5 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"0,8 °C"},{"name":"","range":"1200 °C bis 1300 °C","cmc":"1,3 °C"},{"name":"","range":"1300 °C do 1450 °C","cmc":"1,8 °C"},{"name":"","range":"0,01 °C","cmc":"0,005 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Temperaturmessumformer (mit Temperaturfühlern) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) T /I 9/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer\n(mit Temperaturaufzeichnung)\nTemperaturmessumformer\n(mit Temperaturfühlern)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C do -40 °C","cmc":"0,02 °C"},{"name":"","range":"-40 °C do 250 °C","cmc":"0,01 °C"},{"name":"","range":"250 °C do 660 °C","cmc":"0,12 °C"},{"name":"","range":"660 °C do 1085 °C","cmc":"0,5 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"0,8 °C"},{"name":"","range":"1200 °C 至 1300 °C","cmc":"1,3 °C"},{"name":"","range":"1300 °C do 1450 °C","cmc":"1,8 °C"},{"name":"","range":"0,01 °C","cmc":"0,005 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计 （带温度记录） 温度变送器 （含温度传感器） 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 温度（电测温） 内部程序 直接法 在固定地点 (S) T /I 9/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计\n（带温度记录）\n温度变送器\n（含温度传感器）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C do -40 °C","cmc":"0,02 °C"},{"name":"","range":"-40 °C do 250 °C","cmc":"0,01 °C"},{"name":"","range":"250 °C do 660 °C","cmc":"0,12 °C"},{"name":"","range":"660 °C do 1085 °C","cmc":"0,5 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"0,8 °C"},{"name":"","range":"1200 °C do 1300 °C","cmc":"1,3 °C"},{"name":"","range":"1300 °C do 1450 °C","cmc":"1,8 °C"},{"name":"","range":"0,01 °C","cmc":"0,005 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Převodníky teploty (obsahující teplotní čidla) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) T /I 9/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry\n(se záznamem teploty)\nPřevodníky teploty\n(obsahující teplotní čidla)"},{"_id":"03e45606616a83ac8854014e","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne\n(z rejestracją temperatury)\nPrzetworniki temperatury\n(zawierające czujniki temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers\n(with temperature recording)\nTemperature transmitters\n(containing temperature sensors)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-30 °C do 110 °C","cmc":"0,03 °C"},{"name":"","range":"110 °C do 650 °C","cmc":"0,15 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 110 °C","cmc":"0,03 °C"},{"name":"","range":"110 °C to 650 °C","cmc":"0,15 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 110 °C CMC 0,03 °C\n110 °C do 650 °C CMC 0,15 °C\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"T /I 9/ MAP\nP4 / MAP","norm_bases":["T /I 9/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne\n(z rejestracją temperatury)\nPrzetworniki temperatury\n(zawierające czujniki temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 110 °C CMC 0,03 °C\n110 °C do 650 °C CMC 0,15 °C\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) T /I 9/ MAP\nP4 / MAP Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne\n(z rejestracja temperatury)\nPrzetworniki temperatury\n(zawierajace czujniki temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 110 °C CMC 0,03 °C\n110 °C do 650 °C CMC 0,15 °C\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) T /I 9/ MAP\nP4 / MAP","search_en":"Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Temperature transmitters (containing temperature sensors) Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Direct method Outside of permanent location (P) T /I 9/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":45,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-30 °C to 110 °C","cmc":"0,03 °C"},{"name":"","range":"110 °C to 650 °C","cmc":"0,15 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Temperaturmessumformer (mit Temperaturfühlern) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) T /I 9/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer\n(mit Temperaturaufzeichnung)\nTemperaturmessumformer\n(mit Temperaturfühlern)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-30 °C to 110 °C","cmc":"0,03 °C"},{"name":"","range":"110 °C to 650 °C","cmc":"0,15 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计 （带温度记录） 温度变送器 （含温度传感器） 校准 — 温度（电测温） 内部程序；直接法；固定地点以外 (P) 温度（电测温） 内部程序 直接法 固定地点以外 (P) T /I 9/ MAP P4 / MAP","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计\n（带温度记录）\n温度变送器\n（含温度传感器）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-30 °C to 110 °C","cmc":"0,03 °C"},{"name":"","range":"110 °C to 650 °C","cmc":"0,15 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Převodníky teploty (obsahující teplotní čidla) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) T /I 9/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry\n(se záznamem teploty)\nPřevodníky teploty\n(obsahující teplotní čidla)"},{"_id":"766dfd9df2a59784b0d9b70b","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Termostaty cieczowe","test_object_en":"Liquid baths","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do 250 °C","cmc":"0,02 °C 1)"}],"parameters_en":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,02 °C 1)"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 250 °C CMC 0,02 °C 1)\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"T /I 10/ MAP\nT /I 14/ MAP","norm_bases":["T /I 10/ MAP","T /I 14/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 250 °C CMC 0,02 °C 1)\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) T /I 10/ MAP\nT /I 14/ MAP Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 250 °C CMC 0,02 °C 1)\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) T /I 10/ MAP\nT /I 14/ MAP","search_en":"Liquid baths Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) T /I 10/ MAP T /I 14/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":46,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,02 °C 1)"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Flüssigkeitsthermostate Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) T /I 10/ MAP T /I 14/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Flüssigkeitsthermostate","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,02 °C 1)"}],"regulatory_area_zh":"温度（电测温）","search_zh":"液体恒温槽 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 温度（电测温） 内部程序 直接法 在固定地点 (S) T /I 10/ MAP T /I 14/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"液体恒温槽","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,02 °C 1)"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Kapalinové termostaty Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) T /I 10/ MAP T /I 14/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Kapalinové termostaty"},{"_id":"e128e827206f8254ba4e30f2","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Termostaty cieczowe","test_object_en":"Liquid baths","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do 250 °C","cmc":"0,03 °C 1)"}],"parameters_en":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,03 °C 1)"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 250 °C CMC 0,03 °C 1)\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"T /I 10/ MAP\nT /I 14/ MAP\nP4 / MAP","norm_bases":["T /I 10/ MAP","T /I 14/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 250 °C CMC 0,03 °C 1)\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) T /I 10/ MAP\nT /I 14/ MAP\nP4 / MAP Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 250 °C CMC 0,03 °C 1)\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) T /I 10/ MAP\nT /I 14/ MAP\nP4 / MAP","search_en":"Liquid baths Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Direct method Outside of permanent location (P) T /I 10/ MAP T /I 14/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":47,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,03 °C 1)"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Flüssigkeitsthermostate Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) T /I 10/ MAP T /I 14/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Flüssigkeitsthermostate","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,03 °C 1)"}],"regulatory_area_zh":"温度（电测温）","search_zh":"液体恒温槽 校准 — 温度（电测温） 内部程序；直接法；固定地点以外 (P) 温度（电测温） 内部程序 直接法 固定地点以外 (P) T /I 10/ MAP T /I 14/ MAP P4 / MAP","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"液体恒温槽","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,03 °C 1)"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Kapalinové termostaty Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) T /I 10/ MAP T /I 14/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Kapalinové termostaty"},{"_id":"1e2eba66b71d05db1dac6ba2","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Kalibratory temperatury","test_object_en":"Temperature calibrators","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-50 °C do 660 °C","cmc":"0,12 °C 1)"},{"name":"","range":"660 °C do 1200 °C","cmc":"0,6 °C 1)"}],"parameters_en":[{"name":"","range":"-50 °C to 660 °C","cmc":"0,12 °C 1)"},{"name":"","range":"660 °C to 1200 °C","cmc":"0,6 °C 1)"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 660 °C CMC 0,12 °C 1)\n660 °C do 1200 °C CMC 0,6 °C 1)\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"T /I 12/ MAP\nP4 / MAP w oparciu o EURAMET cg-13 v. 4.0","norm_bases":["T /I 12/ MAP","P4 / MAP","EURAMET cg-13 v. 4.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Kalibratory temperatury Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 660 °C CMC 0,12 °C 1)\n660 °C do 1200 °C CMC 0,6 °C 1)\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) T /I 12/ MAP\nP4 / MAP w oparciu o EURAMET cg-13 v. 4.0 Kalibratory temperatury Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 660 °C CMC 0,12 °C 1)\n660 °C do 1200 °C CMC 0,6 °C 1)\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) T /I 12/ MAP\nP4 / MAP w oparciu o EURAMET cg-13 v. 4.0","search_en":"Temperature calibrators Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) and outside of it (P) T /I 12/ MAP P4 / MAP based on EURAMET cg-13 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":48,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"T /I 12/ MAP\nP4 / MAP based on EURAMET cg-13 v. 4.0","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-50 °C to 660 °C","cmc":"0,12 °C 1)"},{"name":"","range":"660 °C to 1200 °C","cmc":"0,6 °C 1)"}],"reference_de":"T /I 12/ MAP\nP4 / MAP auf Grundlage von EURAMET cg-13 v. 4.0","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Temperaturkalibratoren Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) T /I 12/ MAP P4 / MAP auf Grundlage von EURAMET cg-13 v. 4.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Temperaturkalibratoren","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-50 °C to 660 °C","cmc":"0,12 °C 1)"},{"name":"","range":"660 °C to 1200 °C","cmc":"0,6 °C 1)"}],"reference_zh":"T /I 12/ MAP\nP4 / MAP 依据EURAMET cg-13 v. 4.0","regulatory_area_zh":"温度（电测温）","search_zh":"温度校准器 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) T /I 12/ MAP P4 / MAP 依据EURAMET cg-13 v. 4.0","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"温度校准器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-50 °C to 660 °C","cmc":"0,12 °C 1)"},{"name":"","range":"660 °C to 1200 °C","cmc":"0,6 °C 1)"}],"reference_cs":"T /I 12/ MAP\nP4 / MAP na základě EURAMET cg-13 v. 4.0","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Kalibrátory teploty Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) T /I 12/ MAP P4 / MAP na základě EURAMET cg-13 v. 4.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory teploty"},{"_id":"82b557101513b9ffce6ea95e","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Piece","test_object_en":"Furnaces","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"100 °C do 420 °C","cmc":"0,6 °C 1)"},{"name":"","range":"420 °C do 950 °C","cmc":"1,5 °C 1)"},{"name":"","range":"950 °C do 1200 °C","cmc":"2,0 °C 1)"},{"name":"","range":"1200 °C do 1450 °C","cmc":"3,0 °C 1)"}],"parameters_en":[{"name":"","range":"100 °C to 420 °C","cmc":"0,6 °C 1)"},{"name":"","range":"420 °C to 950 °C","cmc":"1,5 °C 1)"},{"name":"","range":"950 °C to 1200 °C","cmc":"2,0 °C 1)"},{"name":"","range":"1200 °C to 1450 °C","cmc":"3,0 °C 1)"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n100 °C do 420 °C CMC 0,6 °C 1)\n420 °C do 950 °C CMC 1,5 °C 1)\n950 °C do 1200 °C CMC 2,0 °C 1)\n1200 °C do 1450 °C CMC 3,0 °C 1)\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"T /I 10/ MAP\nP4 / MAP","norm_bases":["T /I 10/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Piece Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n100 °C do 420 °C CMC 0,6 °C 1)\n420 °C do 950 °C CMC 1,5 °C 1)\n950 °C do 1200 °C CMC 2,0 °C 1)\n1200 °C do 1450 °C CMC 3,0 °C 1)\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) T /I 10/ MAP\nP4 / MAP Piece Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n100 °C do 420 °C CMC 0,6 °C 1)\n420 °C do 950 °C CMC 1,5 °C 1)\n950 °C do 1200 °C CMC 2,0 °C 1)\n1200 °C do 1450 °C CMC 3,0 °C 1)\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) T /I 10/ MAP\nP4 / MAP","search_en":"Furnaces Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) and outside of it (P) T /I 10/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":49,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"100 °C to 420 °C","cmc":"0,6 °C 1)"},{"name":"","range":"420 °C to 950 °C","cmc":"1,5 °C 1)"},{"name":"","range":"950 °C to 1200 °C","cmc":"2,0 °C 1)"},{"name":"","range":"1200 °C to 1450 °C","cmc":"3,0 °C 1)"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Öfen Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) T /I 10/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Öfen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"100 °C to 420 °C","cmc":"0,6 °C 1)"},{"name":"","range":"420 °C to 950 °C","cmc":"1,5 °C 1)"},{"name":"","range":"950 °C to 1200 °C","cmc":"2,0 °C 1)"},{"name":"","range":"1200 °C to 1450 °C","cmc":"3,0 °C 1)"}],"regulatory_area_zh":"温度（电测温）","search_zh":"炉具 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) T /I 10/ MAP P4 / MAP","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"炉具","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"100 °C to 420 °C","cmc":"0,6 °C 1)"},{"name":"","range":"420 °C to 950 °C","cmc":"1,5 °C 1)"},{"name":"","range":"950 °C to 1200 °C","cmc":"2,0 °C 1)"},{"name":"","range":"1200 °C to 1450 °C","cmc":"3,0 °C 1)"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Pece Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) T /I 10/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Pece"},{"_id":"b33be5cedf8a167f67d13542","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Komory klimatyczne\nKomory termostatyczne","test_object_en":"Climatic chambers\nThermostatic chambers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do 250 °C","cmc":"0,20 °C 1)"},{"name":"","range":"250 °C do 420 °C","cmc":"0,6 °C 1)"}],"parameters_en":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,20 °C 1)"},{"name":"","range":"250 °C to 420 °C","cmc":"0,6 °C 1)"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do 250 °C CMC 0,20 °C 1)\n250 °C do 420 °C CMC 0,6 °C 1)\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"T /I 11/ MAP\nP4 / MAP w oparciu o EURAMET cg-20 v. 5.0","norm_bases":["T /I 11/ MAP","P4 / MAP","EURAMET cg-20 v. 5.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Komory klimatyczne\nKomory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do 250 °C CMC 0,20 °C 1)\n250 °C do 420 °C CMC 0,6 °C 1)\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) T /I 11/ MAP\nP4 / MAP w oparciu o EURAMET cg-20 v. 5.0 Komory klimatyczne\nKomory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do 250 °C CMC 0,20 °C 1)\n250 °C do 420 °C CMC 0,6 °C 1)\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) T /I 11/ MAP\nP4 / MAP w oparciu o EURAMET cg-20 v. 5.0","search_en":"Climatic chambers Thermostatic chambers Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure Direct method At permanent location (S) and outside of it (P) T /I 11/ MAP P4 / MAP based on EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":50,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"T /I 11/ MAP\nP4 / MAP based on EURAMET cg-20 v. 5.0","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,20 °C 1)"},{"name":"","range":"250 °C to 420 °C","cmc":"0,6 °C 1)"}],"reference_de":"T /I 11/ MAP\nP4 / MAP auf Grundlage von EURAMET cg-20 v. 5.0","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Klimakammern Thermostatkammern Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) T /I 11/ MAP P4 / MAP auf Grundlage von EURAMET cg-20 v. 5.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Klimakammern\nThermostatkammern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,20 °C 1)"},{"name":"","range":"250 °C to 420 °C","cmc":"0,6 °C 1)"}],"reference_zh":"T /I 11/ MAP\nP4 / MAP 依据EURAMET cg-20 v. 5.0","regulatory_area_zh":"温度（电测温）","search_zh":"气候箱 恒温箱 校准 — 温度（电测温） 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) T /I 11/ MAP P4 / MAP 依据EURAMET cg-20 v. 5.0","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"气候箱\n恒温箱","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to 250 °C","cmc":"0,20 °C 1)"},{"name":"","range":"250 °C to 420 °C","cmc":"0,6 °C 1)"}],"reference_cs":"T /I 11/ MAP\nP4 / MAP na základě EURAMET cg-20 v. 5.0","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Klimatické komory Termostatické komory Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) T /I 11/ MAP P4 / MAP na základě EURAMET cg-20 v. 5.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Klimatické komory\nTermostatické komory"},{"_id":"79f6cea4531e2e77b8828c93","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Komory do sterylizacji parowej\n(w tym autoklawy)","test_object_en":"Steam sterilization chambers\n(including autoclaves)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"100 °C do 150 °C","cmc":"0,3 °C 1)"}],"parameters_en":[{"name":"","range":"100 °C to 150 °C","cmc":"0,3 °C 1)"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n100 °C do 150 °C CMC 0,3 °C 1)\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P)","reference":"T /I 10/ MAP\nP4 / MAP","norm_bases":["T /I 10/ MAP","P4 / MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Komory do sterylizacji parowej\n(w tym autoklawy) Wzorcowanie — Temperatura (termometria elektryczna)\n100 °C do 150 °C CMC 0,3 °C 1)\nProcedura wewnętrzna; Metoda bezpośrednia; Poza stałą lokalizacją (P) T /I 10/ MAP\nP4 / MAP Komory do sterylizacji parowej\n(w tym autoklawy) Wzorcowanie — Temperatura (termometria elektryczna)\n100 °C do 150 °C CMC 0,3 °C 1)\nProcedura wewnetrzna; Metoda bezposrednia; Poza stala lokalizacja (P) T /I 10/ MAP\nP4 / MAP","search_en":"Steam sterilization chambers (including autoclaves) Calibration — Temperature (electrical thermometry) Internal procedure; Direct method; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Direct method Outside of permanent location (P) T /I 10/ MAP P4 / MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":51,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"100 °C to 150 °C","cmc":"0,3 °C 1)"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Dampfsterilisationskammern (einschließlich Autoklaven) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Direktes Verfahren Außerhalb des festen Standorts (P) T /I 10/ MAP P4 / MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Dampfsterilisationskammern\n(einschließlich Autoklaven)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"100 °C to 150 °C","cmc":"0,3 °C 1)"}],"regulatory_area_zh":"温度（电测温）","search_zh":"蒸汽灭菌室 （包括高压灭菌器） 校准 — 温度（电测温） 内部程序；直接法；固定地点以外 (P) 温度（电测温） 内部程序 直接法 固定地点以外 (P) T /I 10/ MAP P4 / MAP","technique_zh":"内部程序；直接法；固定地点以外 (P)","techniques_zh":["内部程序","直接法","固定地点以外 (P)"],"test_object_zh":"蒸汽灭菌室\n（包括高压灭菌器）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"100 °C to 150 °C","cmc":"0,3 °C 1)"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Komory pro parní sterilizaci (včetně autoklávů) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P) Teplota (elektrická termometrie) Vnitřní postup Přímá metoda Mimo stálou lokalitu (P) T /I 10/ MAP P4 / MAP","technique_cs":"Vnitřní postup; Přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Komory pro parní sterilizaci\n(včetně autoklávů)"},{"_id":"c572c1a9147172dc1a9f3c4d","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Termometry wskazówkowe\n(manometryczne, dylatacyjne i bimetalowe)","test_object_en":"Dial thermometers\n(pressure-spring, expansion and bimetallic)","methodology":"Wzorcowanie — Temperatura (termometria nieelektryczna)","methodology_en":"Calibration — Temperature (non-electrical thermometry)","parameters":[{"name":"","range":"-30 °C do 420 °C","cmc":"0,10 °C"},{"name":"","range":"420 °C do 650 °C","cmc":"0,5 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 420 °C","cmc":"0,10 °C"},{"name":"","range":"420 °C to 650 °C","cmc":"0,5 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-30 °C do 420 °C CMC 0,10 °C\n420 °C do 650 °C CMC 0,5 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"T /I 9/ MAP","norm_bases":["T /I 9/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria nieelektryczna)","regulatory_area_en":"Temperature (non-electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry wskazówkowe\n(manometryczne, dylatacyjne i bimetalowe) Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-30 °C do 420 °C CMC 0,10 °C\n420 °C do 650 °C CMC 0,5 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) T /I 9/ MAP Termometry wskazowkowe\n(manometryczne, dylatacyjne i bimetalowe) Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-30 °C do 420 °C CMC 0,10 °C\n420 °C do 650 °C CMC 0,5 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) T /I 9/ MAP","search_en":"Dial thermometers (pressure-spring, expansion and bimetallic) Calibration — Temperature (non-electrical thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (non-electrical thermometry) Internal procedure Direct method At permanent location (S) T /I 9/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":52,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (nichtelektrische Thermometrie)","parameters_de":[{"name":"","range":"-30 °C to 420 °C","cmc":"0,10 °C"},{"name":"","range":"420 °C to 650 °C","cmc":"0,5 °C"}],"regulatory_area_de":"Temperatur (nichtelektrische Thermometrie)","search_de":"Zeigerthermometer (manometrische, Ausdehnungs- und Bimetallthermometer) Kalibrierung — Temperatur (nichtelektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (nichtelektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) T /I 9/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Zeigerthermometer\n(manometrische, Ausdehnungs- und Bimetallthermometer)","methodology_zh":"校准 — 温度（非电测温）","parameters_zh":[{"name":"","range":"-30 °C to 420 °C","cmc":"0,10 °C"},{"name":"","range":"420 °C to 650 °C","cmc":"0,5 °C"}],"regulatory_area_zh":"温度（非电测温）","search_zh":"指针式温度计 （压力式、膨胀式和双金属式） 校准 — 温度（非电测温） 内部程序；直接法；在固定地点 (S) 温度（非电测温） 内部程序 直接法 在固定地点 (S) T /I 9/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"指针式温度计\n（压力式、膨胀式和双金属式）","methodology_cs":"Kalibrace — Teplota (neelektrická termometrie)","parameters_cs":[{"name":"","range":"-30 °C to 420 °C","cmc":"0,10 °C"},{"name":"","range":"420 °C to 650 °C","cmc":"0,5 °C"}],"regulatory_area_cs":"Teplota (neelektrická termometrie)","search_cs":"Ručkové teploměry (manometrické, dilatační a bimetalové) Kalibrace — Teplota (neelektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (neelektrická termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) T /I 9/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Ručkové teploměry\n(manometrické, dilatační a bimetalové)"},{"_id":"68b493c55a906b5ee0878c52","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Termometry szklane cieczowe","test_object_en":"Liquid-in-glass thermometers","methodology":"Wzorcowanie — Temperatura (termometria nieelektryczna)","methodology_en":"Calibration — Temperature (non-electrical thermometry)","parameters":[{"name":"","range":"-80 °C do 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C do 250 °C","cmc":"0,04 °C"}],"parameters_en":[{"name":"","range":"-80 °C to 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C to 250 °C","cmc":"0,04 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-80 °C do 100 °C CMC 0,03 °C\n100 °C do 250 °C CMC 0,04 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"T /I 8/ MAP","norm_bases":["T /I 8/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria nieelektryczna)","regulatory_area_en":"Temperature (non-electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry szklane cieczowe Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-80 °C do 100 °C CMC 0,03 °C\n100 °C do 250 °C CMC 0,04 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) T /I 8/ MAP Termometry szklane cieczowe Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-80 °C do 100 °C CMC 0,03 °C\n100 °C do 250 °C CMC 0,04 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) T /I 8/ MAP","search_en":"Liquid-in-glass thermometers Calibration — Temperature (non-electrical thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (non-electrical thermometry) Internal procedure Direct method At permanent location (S) T /I 8/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":53,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (nichtelektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C to 250 °C","cmc":"0,04 °C"}],"regulatory_area_de":"Temperatur (nichtelektrische Thermometrie)","search_de":"Flüssigkeits-Glasthermometer Kalibrierung — Temperatur (nichtelektrische Thermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (nichtelektrische Thermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) T /I 8/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Flüssigkeits-Glasthermometer","methodology_zh":"校准 — 温度（非电测温）","parameters_zh":[{"name":"","range":"-80 °C to 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C to 250 °C","cmc":"0,04 °C"}],"regulatory_area_zh":"温度（非电测温）","search_zh":"玻璃液体温度计 校准 — 温度（非电测温） 内部程序；直接法；在固定地点 (S) 温度（非电测温） 内部程序 直接法 在固定地点 (S) T /I 8/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"玻璃液体温度计","methodology_cs":"Kalibrace — Teplota (neelektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to 100 °C","cmc":"0,03 °C"},{"name":"","range":"100 °C to 250 °C","cmc":"0,04 °C"}],"regulatory_area_cs":"Teplota (neelektrická termometrie)","search_cs":"Skleněné kapalinové teploměry Kalibrace — Teplota (neelektrická termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (neelektrická termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) T /I 8/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Skleněné kapalinové teploměry"},{"_id":"efe16e152e7bad24328707a8","lab_id":"6afad8068989a133b76447bf","country":"PL","accr_number":"AP 013","accr_body":"PCA","test_object":"Pirometry radiacyjne\nPirometry fotoelektryczne\nKamery termowizyjne","test_object_en":"Radiation pyrometers\nPhotoelectric pyrometers\nThermal imaging cameras","methodology":"Wzorcowanie — Temperatura (termometria radiacyjna)","methodology_en":"Calibration — Temperature (radiation thermometry)","parameters":[{"name":"","range":"-15 °C do 0 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C do 50 °C","cmc":"1,4 °C"},{"name":"","range":"50 °C do 100 °C","cmc":"1,8 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"2,3 °C"},{"name":"","range":"200 °C do 350 °C","cmc":"3,0 °C"},{"name":"","range":"350 °C do 500 °C","cmc":"3,9 °C"}],"parameters_en":[{"name":"","range":"-15 °C do 0 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C do 50 °C","cmc":"1,4 °C"},{"name":"","range":"50 °C do 100 °C","cmc":"1,8 °C"},{"name":"","range":"100 °C to 200 °C","cmc":"2,3 °C"},{"name":"","range":"200 °C do 350 °C","cmc":"3,0 °C"},{"name":"","range":"350 °C do 500 °C","cmc":"3,9 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-15 °C do 0 °C CMC 1,6 °C\n0 °C do 50 °C CMC 1,4 °C\n50 °C do 100 °C CMC 1,8 °C\n100 °C do 200 °C CMC 2,3 °C\n200 °C do 350 °C CMC 3,0 °C\n350 °C do 500 °C CMC 3,9 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"T /I 13/ MAP","norm_bases":["T /I 13/ MAP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria radiacyjna)","regulatory_area_en":"Temperature (radiation thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pirometry radiacyjne\nPirometry fotoelektryczne\nKamery termowizyjne Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-15 °C do 0 °C CMC 1,6 °C\n0 °C do 50 °C CMC 1,4 °C\n50 °C do 100 °C CMC 1,8 °C\n100 °C do 200 °C CMC 2,3 °C\n200 °C do 350 °C CMC 3,0 °C\n350 °C do 500 °C CMC 3,9 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) T /I 13/ MAP Pirometry radiacyjne\nPirometry fotoelektryczne\nKamery termowizyjne Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-15 °C do 0 °C CMC 1,6 °C\n0 °C do 50 °C CMC 1,4 °C\n50 °C do 100 °C CMC 1,8 °C\n100 °C do 200 °C CMC 2,3 °C\n200 °C do 350 °C CMC 3,0 °C\n350 °C do 500 °C CMC 3,9 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) T /I 13/ MAP","search_en":"Radiation pyrometers Photoelectric pyrometers Thermal imaging cameras Calibration — Temperature (radiation thermometry) Internal procedure; Direct method; At permanent location (S) Temperature (radiation thermometry) Internal procedure Direct method At permanent location (S) T /I 13/ MAP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":54,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (Strahlungsthermometrie)","parameters_de":[{"name":"","range":"-15 °C do 0 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C do 50 °C","cmc":"1,4 °C"},{"name":"","range":"50 °C do 100 °C","cmc":"1,8 °C"},{"name":"","range":"100 °C bis 200 °C","cmc":"2,3 °C"},{"name":"","range":"200 °C do 350 °C","cmc":"3,0 °C"},{"name":"","range":"350 °C do 500 °C","cmc":"3,9 °C"}],"regulatory_area_de":"Temperatur (Strahlungsthermometrie)","search_de":"Strahlungspyrometer Fotoelektrische Pyrometer Wärmebildkameras Kalibrierung — Temperatur (Strahlungsthermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Temperatur (Strahlungsthermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) T /I 13/ MAP","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Strahlungspyrometer\nFotoelektrische Pyrometer\nWärmebildkameras","methodology_zh":"校准 — 温度（辐射测温）","parameters_zh":[{"name":"","range":"-15 °C do 0 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C do 50 °C","cmc":"1,4 °C"},{"name":"","range":"50 °C do 100 °C","cmc":"1,8 °C"},{"name":"","range":"100 °C 至 200 °C","cmc":"2,3 °C"},{"name":"","range":"200 °C do 350 °C","cmc":"3,0 °C"},{"name":"","range":"350 °C do 500 °C","cmc":"3,9 °C"}],"regulatory_area_zh":"温度（辐射测温）","search_zh":"辐射高温计 光电高温计 热像仪 校准 — 温度（辐射测温） 内部程序；直接法；在固定地点 (S) 温度（辐射测温） 内部程序 直接法 在固定地点 (S) T /I 13/ MAP","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"辐射高温计\n光电高温计\n热像仪","methodology_cs":"Kalibrace — Teplota (radiační termometrie)","parameters_cs":[{"name":"","range":"-15 °C do 0 °C","cmc":"1,6 °C"},{"name":"","range":"0 °C do 50 °C","cmc":"1,4 °C"},{"name":"","range":"50 °C do 100 °C","cmc":"1,8 °C"},{"name":"","range":"100 °C do 200 °C","cmc":"2,3 °C"},{"name":"","range":"200 °C do 350 °C","cmc":"3,0 °C"},{"name":"","range":"350 °C do 500 °C","cmc":"3,9 °C"}],"regulatory_area_cs":"Teplota (radiační termometrie)","search_cs":"Radiační pyrometry Fotoelektrické pyrometry Termovizní kamery Kalibrace — Teplota (radiační termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Teplota (radiační termometrie) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) T /I 13/ MAP","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Radiační pyrometry\nFotoelektrické pyrometry\nTermovizní kamery"}],"has_pdf":true}