🇵🇱 WODOCIĄGI MIEJSKIE W RADOMIU Sp. z o.o. PL
Water & wastewaterMicrobiology
WODOCIĄGI MIEJSKIE W RADOMIU Sp. z o.o. is a laboratory accredited by PCA under number AB 990 (Radom, Poland). Its accreditation scope covers 30 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Wastewater, Water, Water, Water intended for human consumption, Water intended for human consumption, Wastewater. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Electrochemical method.
At a glance
- Accreditation number: PCA AB 990
- Methods in scope: 30
- Types of test objects: 4
- Techniques used: 10
- City: Radom, Poland
- Accreditation number
- AB 990
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZE, ul. Filtrowa 4, 26-600 Radom
- City
- Radom, Poland
What this laboratory tests (4)
- Wastewater, Water — 13 methods
- Water, Water intended for human consumption — 9 methods
- Water intended for human consumption — 6 methods
- Wastewater — 2 methods
Analytical techniques used (10)
- Spectrophotometric method — 13 methods
- Membrane filtration method — 3 methods
- Electrochemical method — 2 methods
- Gravimetric method — 2 methods
- Plate method (pour plate) — 2 methods
- Potentiometric method — 2 methods
- Titrimetric method — 2 methods
- Conductometric method — 1 method
- Manual and automatic method — 1 method
- Nephelometric method — 1 method
Accreditation scope — test methods (30)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Wastewater | Sampling for chemical and physical testing Temperature of the collected wastewater sample Range (1,0 – 50,0) oC |
Manual and automatic method | PN-ISO 5667-10:2021-11 PO-08.03 wydanie: 7 obowiązuje od: 22.04.2024 r. | |
| 2 | Wastewater | Anionic surfactant concentration Range (0,20 – 500) mg/l |
Spectrophotometric method | PN-EN 903:2002 | |
| 3 | Wastewater, Water | Chemical oxygen demand-COD-Cr Range (10,0 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 4 | Wastewater, Water | Total nitrogen concentration Range (1,0 – 300) mg/l |
Spectrophotometric method | PO-08.04 wydanie: 9 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 138, LCK 338 w oparciu o test HACH LANGE LCK 138, LCK 338 | |
| 5 | Wastewater, Water | Total phosphorus concentration Range (0,10 – 20) mg/l |
Spectrophotometric method | PO-08.01 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 349, LCK 350 w oparciu o test HACH LANGE LCK 349, LCK 350 | |
| 6 | Wastewater, Water | Total suspended solids (TSS) Range (10 – 12000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 7 | Wastewater, Water | Ammonium nitrogen concentration Range (0,10 – 70) mg/l |
Spectrophotometric method | PO-08.05 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 303, LCK 304 w oparciu o test HACH LANGE LCK 303, LCK 304 | |
| 8 | Wastewater, Water | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 9 | Wastewater, Water | Concentration of substances extractable with petroleum ether Range (10 – 3000) mg/l |
Gravimetric method | PO-08.15 wydanie: 8 obowiązuje od: 22.04.2024 r. | |
| 10 | Wastewater, Water | Biochemical oxygen demand – BOD5 Range (0,50 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 11 | Wastewater, Water | Total phosphorus concentration Range (0,10 – 58) mg/l |
Spectrophotometric method | PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010 | PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010 | |
| 12 | Wastewater, Water | Ammonium nitrogen concentration Range (0,10 – 80) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 13 | Wastewater, Water | Biochemical oxygen demand – BOD5 Range (3 – 6 000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 14 | Wastewater, Water | Chloride concentration Range (5 – 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 15 | Wastewater, Water | Nitrite concentration Range (0,10 – 8,2) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 16 | Water, Water intended for human consumption | Manganese concentration Range (0,020 − 0,25) mg/l |
Spectrophotometric method | PN-92/C-04590/02 | |
| 17 | Water, Water intended for human consumption | Turbidity Range (0,20 − 25) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 18 | Water, Water intended for human consumption | Nitrite concentration Range (0,010 − 0,50) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 19 | Water, Water intended for human consumption | Nitrate concentration Range (1,0 − 50) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 20 | Water, Water intended for human consumption | Electrical conductivity Range (84 − 2500) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 21 | Water, Water intended for human consumption | Total iron concentration Range (0,010 – 5,0) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 22 | Water, Water intended for human consumption | Ammonium ion concentration Range (0,10 – 0,80) mg/l |
Spectrophotometric method | PN-C-04576-4:1994 | |
| 23 | Water, Water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (12 – 980) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 24 | Water, Water intended for human consumption | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 25 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 26 | Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014+A1:2017-04 | |
| 27 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014+A1:2017-04 | |
| 28 | Water intended for human consumption | Enterococci (faecal streptococci) count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 29 | Water intended for human consumption | Total viable count at 36 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 30 | Water intended for human consumption | Total viable count at 22 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
Reference standards (26)
PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010
PN-82/C-04576.08
PN-92/C-04590/02
PN-C-04576-4:1994
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014+A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11 PO-08.03 wydanie: 7 obowiązuje od: 22.04.2024 r.
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994
PO-08.01 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 349, LCK 350 w oparciu o test HACH LANGE LCK 349, LCK 350
PO-08.04 wydanie: 9 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 138, LCK 338 w oparciu o test HACH LANGE LCK 138, LCK 338
PO-08.05 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 303, LCK 304 w oparciu o test HACH LANGE LCK 303, LCK 304
PO-08.15 wydanie: 8 obowiązuje od: 22.04.2024 r.