🇵🇱 WODOCIĄGI MIEJSKIE W RADOMIU Sp. z o.o. PL

PCA AB 990 • Radom, Poland • 30 methods

Water & wastewaterMicrobiology

WODOCIĄGI MIEJSKIE W RADOMIU Sp. z o.o. is a laboratory accredited by PCA under number AB 990 (Radom, Poland). Its accreditation scope covers 30 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Wastewater, Water, Water, Water intended for human consumption, Water intended for human consumption, Wastewater. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Electrochemical method.

At a glance

  • Accreditation number: PCA AB 990
  • Methods in scope: 30
  • Types of test objects: 4
  • Techniques used: 10
  • City: Radom, Poland
Accreditation number
AB 990
Accreditation body
PCA
Address
LABORATORIUM BADAWCZE, ul. Filtrowa 4, 26-600 Radom
City
Radom, Poland

What this laboratory tests (4)

Analytical techniques used (10)

Accreditation scope — test methods (30)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (1,0 – 50,0) oC
Manual and automatic method PN-ISO 5667-10:2021-11 PO-08.03 wydanie: 7 obowiązuje od: 22.04.2024 r.
2 Wastewater Anionic surfactant concentration
Range (0,20 – 500) mg/l
Spectrophotometric method PN-EN 903:2002
3 Wastewater, Water Chemical oxygen demand-COD-Cr
Range (10,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
4 Wastewater, Water Total nitrogen concentration
Range (1,0 – 300) mg/l
Spectrophotometric method PO-08.04 wydanie: 9 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 138, LCK 338 w oparciu o test HACH LANGE LCK 138, LCK 338
5 Wastewater, Water Total phosphorus concentration
Range (0,10 – 20) mg/l
Spectrophotometric method PO-08.01 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 349, LCK 350 w oparciu o test HACH LANGE LCK 349, LCK 350
6 Wastewater, Water Total suspended solids (TSS)
Range (10 – 12000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
7 Wastewater, Water Ammonium nitrogen concentration
Range (0,10 – 70) mg/l
Spectrophotometric method PO-08.05 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 303, LCK 304 w oparciu o test HACH LANGE LCK 303, LCK 304
8 Wastewater, Water pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
9 Wastewater, Water Concentration of substances extractable with petroleum ether
Range (10 – 3000) mg/l
Gravimetric method PO-08.15 wydanie: 8 obowiązuje od: 22.04.2024 r.
10 Wastewater, Water Biochemical oxygen demand – BOD5
Range (0,50 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
11 Wastewater, Water Total phosphorus concentration
Range (0,10 – 58) mg/l
Spectrophotometric method PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010 | PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010
12 Wastewater, Water Ammonium nitrogen concentration
Range (0,10 – 80) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
13 Wastewater, Water Biochemical oxygen demand – BOD5
Range (3 – 6 000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
14 Wastewater, Water Chloride concentration
Range (5 – 400) mg/l
Titrimetric method PN-ISO 9297:1994
15 Wastewater, Water Nitrite concentration
Range (0,10 – 8,2) mg/l
Spectrophotometric method PN-EN 26777:1999
16 Water, Water intended for human consumption Manganese concentration
Range (0,020 − 0,25) mg/l
Spectrophotometric method PN-92/C-04590/02
17 Water, Water intended for human consumption Turbidity
Range (0,20 − 25) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
18 Water, Water intended for human consumption Nitrite concentration
Range (0,010 − 0,50) mg/l
Spectrophotometric method PN-EN 26777:1999
19 Water, Water intended for human consumption Nitrate concentration
Range (1,0 − 50) mg/l
Spectrophotometric method PN-82/C-04576.08
20 Water, Water intended for human consumption Electrical conductivity
Range (84 − 2500) μS/cm
Conductometric method PN-EN 27888:1999
21 Water, Water intended for human consumption Total iron concentration
Range (0,010 – 5,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
22 Water, Water intended for human consumption Ammonium ion concentration
Range (0,10 – 0,80) mg/l
Spectrophotometric method PN-C-04576-4:1994
23 Water, Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (12 – 980) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
24 Water, Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
25 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
26 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014+A1:2017-04
27 Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014+A1:2017-04
28 Water intended for human consumption Enterococci (faecal streptococci) count Membrane filtration method PN-EN ISO 7899-2:2004
29 Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
30 Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004

Reference standards (26)

PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010
PN-82/C-04576.08
PN-92/C-04590/02
PN-C-04576-4:1994
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014+A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11 PO-08.03 wydanie: 7 obowiązuje od: 22.04.2024 r.
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994
PO-08.01 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 349, LCK 350 w oparciu o test HACH LANGE LCK 349, LCK 350
PO-08.04 wydanie: 9 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 138, LCK 338 w oparciu o test HACH LANGE LCK 138, LCK 338
PO-08.05 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 303, LCK 304 w oparciu o test HACH LANGE LCK 303, LCK 304
PO-08.15 wydanie: 8 obowiązuje od: 22.04.2024 r.