{"lab":{"_id":"69ad52a3de79e566650fb4fc","accr_number":"AB 990","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE, ul. Filtrowa 4, 26-600 Radom","categories":["water","microbiology"],"city":"Radom","imported_at":"2026-03-08T10:42:43.265Z","methods_count":30,"name":"WODOCIĄGI MIEJSKIE W RADOMIU Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_990.pdf"],"scope_summary":"","search_text":"wodociągi miejskie w radomiu sp. z o.o. laboratorium badawcze, ul. filtrowa 4, 26-600 radom water other pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:51:52.647Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:52.647Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20990,podmiot.html","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"N/29P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"K/29","pl":"Badania mikrobiologiczne wody do spożycia przez ludzi","en":"Microbiological tests of drinking water"}],"issue":{"no":"18","date":"30.10.2025"},"parse_date":"2026-07-20T07:09:56.496Z","parse_source":"script-pdfplumber","map_coord":[51.406266,21.16604],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":30,"microbiology":2},"category_scores":{"water":28.13,"microbiology":0.13},"has_zh":true},"methods":[{"_id":"6a5dc9c4f1c10c8ce826010a","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(1,0 – 50,0) oC"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(1,0 – 50,0) oC"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"technique_en":"Manual and automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (1,0 – 50,0) oC\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 PO-08.03 wydanie: 7 obowiązuje od: 22.04.2024 r.","norm_bases":["PN-ISO 5667-10:2021-11 PO-08.03 wydanie: 7 obowiązuje od: 22.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (1,0 – 50,0) oC\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 PO-08.03 wydanie: 7 obowiązuje od: 22.04.2024 r. Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (1,0 – 50,0) oC\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 PO-08.03 wydanie: 7 obowiazuje od: 22.04.2024 r.","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 PO-08.03 wydanie: 7 obowiązuje od: 22.04.2024 r.","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(1,0 – 50,0) oC"}],"search_zh":"污水 化学与物理检测用样品采集 手工与自动法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 PO-08.03 wydanie: 7 obowiązuje od: 22.04.2024 r.","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a5dc9c4f1c10c8ce826010b","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie surfaktantów anionowych","methodology_en":"Anionic surfactant concentration","parameters":[{"name":"Zakres","range":"(0,20 – 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 – 500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie surfaktantów anionowych\nZakres (0,20 – 500) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie surfaktantów anionowych\nZakres (0,20 – 500) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Scieki Stezenie surfaktantow anionowych\nZakres (0,20 – 500) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Anionic surfactant concentration Spectrophotometric method Range PN-EN 903:2002","parameters_zh":[{"name":"范围","range":"(0,20 – 500) mg/l"}],"search_zh":"污水 阴离子表面活性剂浓度 分光光度法 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"阴离子表面活性剂浓度"},{"_id":"6a5dc9c4f1c10c8ce826010c","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Chemiczne zapotrzebowanie tlenu-ChZT-Cr","methodology_en":"Chemical oxygen demand-COD-Cr","parameters":[{"name":"Zakres","range":"(10,0 – 10000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(10,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu-ChZT-Cr\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Chemiczne zapotrzebowanie tlenu-ChZT-Cr\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, Woda Chemiczne zapotrzebowanie tlenu-ChZT-Cr\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Chemical oxygen demand-COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(10,0 – 10000) mg/l O2"}],"search_zh":"废水、水 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce826010d","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 300) mg/l\nMetoda spektrofotometryczna","reference":"PO-08.04 wydanie: 9 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 138, LCK 338 w oparciu o test HACH LANGE LCK 138, LCK 338","norm_bases":["PO-08.04 wydanie: 9 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 138, LCK 338 w oparciu o test HACH LANGE LCK 138, LCK 338"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie azotu ogólnego\nZakres (1,0 – 300) mg/l\nMetoda spektrofotometryczna PO-08.04 wydanie: 9 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 138, LCK 338 w oparciu o test HACH LANGE LCK 138, LCK 338 Scieki, Woda Stezenie azotu ogolnego\nZakres (1,0 – 300) mg/l\nMetoda spektrofotometryczna PO-08.04 wydanie: 9 obowiazuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 138, LCK 338 w oparciu o test HACH LANGE LCK 138, LCK 338","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Total nitrogen concentration Spectrophotometric method Range PO-08.04 wydanie: 9 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 138, LCK 338 w oparciu o test HACH LANGE LCK 138, LCK 338","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 300) mg/l"}],"search_zh":"废水、水 总氮浓度 分光光度法 范围 PO-08.04 wydanie: 9 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 138, LCK 338 w oparciu o test HACH LANGE LCK 138, LCK 338","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce826010e","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PO-08.01 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 349, LCK 350 w oparciu o test HACH LANGE LCK 349, LCK 350","norm_bases":["PO-08.01 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 349, LCK 350 w oparciu o test HACH LANGE LCK 349, LCK 350"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie fosforu ogólnego\nZakres (0,10 – 20) mg/l\nMetoda spektrofotometryczna PO-08.01 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 349, LCK 350 w oparciu o test HACH LANGE LCK 349, LCK 350 Scieki, Woda Stezenie fosforu ogolnego\nZakres (0,10 – 20) mg/l\nMetoda spektrofotometryczna PO-08.01 wydanie: 7 obowiazuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 349, LCK 350 w oparciu o test HACH LANGE LCK 349, LCK 350","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Total phosphorus concentration Spectrophotometric method Range PO-08.01 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 349, LCK 350 w oparciu o test HACH LANGE LCK 349, LCK 350","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/l"}],"search_zh":"废水、水 总磷浓度 分光光度法 范围 PO-08.01 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 349, LCK 350 w oparciu o test HACH LANGE LCK 349, LCK 350","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce826010f","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(10 – 12000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 12000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (10 – 12000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Zawiesiny ogólne\nZakres (10 – 12000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, Woda Zawiesiny ogolne\nZakres (10 – 12000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(10 – 12000) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce8260110","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,10 – 70) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 70) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,10 – 70) mg/l\nMetoda spektrofotometryczna","reference":"PO-08.05 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 303, LCK 304 w oparciu o test HACH LANGE LCK 303, LCK 304","norm_bases":["PO-08.05 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 303, LCK 304 w oparciu o test HACH LANGE LCK 303, LCK 304"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie azotu amonowego\nZakres (0,10 – 70) mg/l\nMetoda spektrofotometryczna PO-08.05 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 303, LCK 304 w oparciu o test HACH LANGE LCK 303, LCK 304 Scieki, Woda Stezenie azotu amonowego\nZakres (0,10 – 70) mg/l\nMetoda spektrofotometryczna PO-08.05 wydanie: 7 obowiazuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 303, LCK 304 w oparciu o test HACH LANGE LCK 303, LCK 304","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Ammonium nitrogen concentration Spectrophotometric method Range PO-08.05 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 303, LCK 304 w oparciu o test HACH LANGE LCK 303, LCK 304","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 70) mg/l"}],"search_zh":"废水、水 氨氮浓度 分光光度法 范围 PO-08.05 wydanie: 7 obowiązuje od: 22.04.2024 r. w oparciu o test HACH LANGE LCK 303, LCK 304 w oparciu o test HACH LANGE LCK 303, LCK 304","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce8260111","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, Woda pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"废水、水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce8260112","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","methodology_en":"Concentration of substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(10 – 3000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 – 3000) mg/l\nMetoda wagowa","reference":"PO-08.15 wydanie: 8 obowiązuje od: 22.04.2024 r.","norm_bases":["PO-08.15 wydanie: 8 obowiązuje od: 22.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 – 3000) mg/l\nMetoda wagowa PO-08.15 wydanie: 8 obowiązuje od: 22.04.2024 r. Scieki, Woda Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (10 – 3000) mg/l\nMetoda wagowa PO-08.15 wydanie: 8 obowiazuje od: 22.04.2024 r.","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Concentration of substances extractable with petroleum ether Gravimetric method Range PO-08.15 wydanie: 8 obowiązuje od: 22.04.2024 r.","parameters_zh":[{"name":"范围","range":"(10 – 3000) mg/l"}],"search_zh":"废水、水 石油醚可萃取物浓度 重量法 范围 PO-08.15 wydanie: 8 obowiązuje od: 22.04.2024 r.","technique_zh":"重量法","test_object_zh":"废水、水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a5dc9c4f1c10c8ce8260113","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki, Woda Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Biochemical oxygen demand – BOD5 Electrochemical method Range PN-EN 1899-2:2002","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"废水、水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"废水、水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c4f1c10c8ce8260114","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,10 – 58) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 58) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 – 58) mg/l\nMetoda spektrofotometryczna","reference":"PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010 | PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010","norm_bases":["PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010","PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie fosforu ogólnego\nZakres (0,10 – 58) mg/l\nMetoda spektrofotometryczna PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010 | PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010 Scieki, Woda Stezenie fosforu ogolnego\nZakres (0,10 – 58) mg/l\nMetoda spektrofotometryczna PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010 | PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Total phosphorus concentration Spectrophotometric method Range PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010 | PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 58) mg/l"}],"search_zh":"废水、水 总磷浓度 分光光度法 范围 PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010 | PN EN-ISO 6878:2006 p.8 + Ap1:2010+ Ap2:2010","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce8260115","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,10 – 80) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,10 – 80) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie azotu amonowego\nZakres (0,10 – 80) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki, Woda Stezenie azotu amonowego\nZakres (0,10 – 80) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 80) mg/l"}],"search_zh":"废水、水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce8260116","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(3 – 6 000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3 – 6 000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6 000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6 000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki, Woda Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6 000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Biochemical oxygen demand – BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3 – 6 000) mg/l O2"}],"search_zh":"废水、水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"废水、水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c4f1c10c8ce8260117","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 – 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie chlorków\nZakres (5 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, Woda Stezenie chlorkow\nZakres (5 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 400) mg/l"}],"search_zh":"废水、水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce8260118","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,10 – 8,2) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 8,2) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,10 – 8,2) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie azotynów\nZakres (0,10 – 8,2) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki, Woda Stezenie azotynow\nZakres (0,10 – 8,2) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 8,2) mg/l"}],"search_zh":"废水、水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce8260119","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(0,020 − 0,25) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,020 − 0,25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (0,020 − 0,25) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/02","norm_bases":["PN-92/C-04590/02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,020 − 0,25) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/02 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,020 − 0,25) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/02","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590/02","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,020 − 0,25) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590/02","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce826011a","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20 − 25) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20 − 25) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20 − 25) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,20 − 25) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,20 − 25) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 − 25) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce826011b","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,010 − 0,50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 − 0,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,010 − 0,50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,010 − 0,50) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,010 − 0,50) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,010 − 0,50) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce826011c","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(1,0 − 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 − 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (1,0 − 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów\nZakres (1,0 − 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Woda do spozycia przez ludzi Stezenie azotanow\nZakres (1,0 − 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,0 − 50) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce826011d","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(84 − 2500) μS/cm"}],"parameters_en":[{"name":"Range","range":"(84 − 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (84 − 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (84 − 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (84 − 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(84 − 2500) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce826011e","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,010 – 5,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 5,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce826011f","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,10 – 0,80) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 0,80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,10 – 0,80) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,10 – 0,80) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,10 – 0,80) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-C-04576-4:1994","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 0,80) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260120","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(12 – 980) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(12 – 980) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (12 – 980) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (12 – 980) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (12 – 980) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(12 – 980) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260121","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260122","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260123","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014+A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014+A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014+A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014+A1:2017-04","categories":["water","microbiology"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014+A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014+A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260124","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014+A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014+A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014+A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014+A1:2017-04","categories":["water","microbiology"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014+A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014+A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260125","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba enterokoków (paciorkowców kałowych)","methodology_en":"Enterococci (faecal streptococci) count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków (paciorkowców kałowych)\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków (paciorkowców kałowych)\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow (paciorkowcow kalowych)\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Enterococci (faecal streptococci) count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"生活饮用水 肠球菌（粪链球菌）数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"肠球菌（粪链球菌）数"},{"_id":"6a5dc9c4f1c10c8ce8260126","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36 °C","methodology_en":"Total viable count at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","methodology_zh":"36 °C 微生物总数"},{"_id":"6a5dc9c4f1c10c8ce8260127","lab_id":"69ad52a3de79e566650fb4fc","country":"PL","accr_number":"AB 990","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22 °C","methodology_en":"Total viable count at 22 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","methodology_zh":"22 °C 微生物总数"}],"has_pdf":true}