🇵🇱 SĄDECKIE WODOCIĄGI Sp. z o.o. PL
Water & wastewaterMicrobiology
SĄDECKIE WODOCIĄGI Sp. z o.o. is a laboratory accredited by PCA under number AB 980 (Nowy Sącz, Poland). Its accreditation scope covers 54 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Water, Water intended for human consumption, Wastewater, Wastewater, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 980
- Methods in scope: 54
- Types of test objects: 8
- Techniques used: 17
- City: Nowy Sącz, Poland
- Accreditation number
- AB 980
- Accreditation body
- PCA
- Address
- LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. Wincentego Pola 22, 33-300 Nowy Sącz
- City
- Nowy Sącz, Poland
What this laboratory tests (8)
- Water, Water intended for human consumption — 18 methods
- Water, Water intended for human consumption, Wastewater — 11 methods
- Wastewater — 8 methods
- Water intended for human consumption — 5 methods
- Surface water — 4 methods
- Water — 3 methods
- Water, Wastewater — 3 methods
- Rainwater, snowmelt water — 2 methods
Analytical techniques used (17)
- Spectrophotometric method — 7 methods
- Membrane filtration method — 6 methods
- Titrimetric method — 6 methods
- Conductometric method — 2 methods
- Electrochemical method — 2 methods
- Gravimetric method — 2 methods
- Plate method (pour plate) — 2 methods
- Qualitative method — 2 methods
- Simplified method, paired, non-forced choice — 2 methods
- Colorimetric method — 1 method
- Electrothermal atomization atomic absorption spectrometry (ETAAS) — 1 method
- Manual method — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
- Potentiometric method — 1 method
- and 2 more
Accreditation scope — test methods (54)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Wastewater | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 2 | Wastewater | Temperature Range (1,0 – 40,0) °C |
PN-ISO 5667-10:2021-11 | PN-77/C-04584 | ||
| 3 | Rainwater, snowmelt water | Sampling for chemical and physical testing | Manual method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 4 | Rainwater, snowmelt water | Temperature Range (1,0 – 40,0) °C |
PN-ISO 5667-10:2021-11 | PN-77/C-04584 | ||
| 5 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 6 | Water intended for human consumption | Coliform bacteria count | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | PN-EN ISO 9308-1:2014-12 | ||
| 7 | Water intended for human consumption | Membrane filtration method | +A1:2017-04 | ||
| 8 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | +A1:2017-04 | |
| 9 | Water | Sampling for testing | PN-EN ISO 19458:2007 z wył. pkt. | ||
| 10 | Water intended for human consumption | microbiological | 4.4.3, 4.4.5, 4.4.6. | ||
| 11 | Surface water | Sampling for testing | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, 9.4 | PN-77/C-04584 | PN-EN ISO 5667-6:2016-12 | ||
| 12 | Surface water | chemical and physical (including | z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, | ||
| 13 | Surface water | sensory) | 9.4 | ||
| 14 | Surface water | Temperature Range (1,0 – 40,0) °C |
PN-77/C-04584 | ||
| 15 | Wastewater | Ammonium nitrogen concentration Range (1 – 200) mg/I |
Titrimetric method | PN-ISO 5664:2002 | |
| 16 | Wastewater | Kjeldahl nitrogen concentration Range (2,0 – 500) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 17 | Wastewater | Chemical oxygen demand COD Range (30 – 6000) mg/l O2 |
Titrimetric method | PN-ISO 6060:2006 | |
| 18 | Wastewater | Biochemical oxygen demand BOD5 Range (3 – 2000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 19 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 20 | Wastewater | Electrical conductivity Range (100 – 3900) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 21 | Water | Biochemical oxygen demand – BOD5 Range (0,5 – 6,0) mg/l O2 |
Electrochemical method | PN-EN ISO 1899-2:2002 | |
| 22 | Water | Chemical oxygen demand - COD Range (2,0 – 40) mg/l O2 |
Spectrophotometric method | PN ISO15705:2005 | |
| 23 | Water, Wastewater | Phenol index Range (0,005 – 1,0) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 metoda B | |
| 24 | Water, Wastewater | Substances extractable with petroleum ether Range (2,0 – 200) mg/l |
Gravimetric method | PB/PBW/02/2025 Edycja I z dnia 05.05.2025 PB/PBW/02/2025 Edycja I z dnia 05.05.2025 | |
| 25 | Water, Wastewater | Sulfate concentration Range ( 5,0-200) mg/l |
Turbidimetric method | PN-79/C-04566/10 | |
| 26 | Water, Water intended for human consumption, Wastewater | Nitrate nitrogen concentration Range (0,2 – 50,0) mg/l |
PN-82/C-04576/08 | ||
| 27 | Water, Water intended for human consumption, Wastewater | Nitrate concentration Range (0,88 – 220,0) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 28 | Water, Water intended for human consumption, Wastewater | Nitrite nitrogen concentration Range (0,01 – 0,20) mg/l |
PN-EN 26777:1999 | ||
| 29 | Water, Water intended for human consumption, Wastewater | Nitrite concentration Range (0,04 – 0,80) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 30 | Water, Water intended for human consumption, Wastewater | Chloride concentration Range (5,0 – 300) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 31 | Water, Water intended for human consumption, Wastewater | Orthophosphate concentration | PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.4 | ||
| 32 | Water, Water intended for human consumption, Wastewater | Range (0,04 – 0,2) mg/l |
Spectrophotometric method | +Ap1:2010+Ap2:2010 | |
| 33 | Water, Water intended for human consumption, Wastewater | Total phosphorus concentration | PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.7 | ||
| 34 | Water, Water intended for human consumption, Wastewater | Range (0,04 – 18,0) mg/l |
Spectrophotometric method | +Ap1:2010+Ap2:2010 | |
| 35 | Water, Water intended for human consumption, Wastewater | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 36 | Water, Water intended for human consumption, Wastewater | Total suspended solids (TSS) Range (2,0 – 2000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 37 | Water, Water intended for human consumption | Electrical conductivity Range (84 – 3900) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 38 | Water, Water intended for human consumption | Calcium concentration Range (2 – 300) mg/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 39 | Water, Water intended for human consumption | Total hardness (total calcium and magnesium concentration) Range (10 – 700) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 40 | Water, Water intended for human consumption | Total iron concentration Range (0,050 – 1,0) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 41 | Water, Water intended for human consumption | Total count of microorganisms at 22 ± 2°C after 72 h | Plate method (pour plate) | PN-EN 6222:2004 | |
| 42 | Water, Water intended for human consumption | Total count of microorganisms at 36 ± 2°C after 48 h | Plate method (pour plate) | PN-EN 6222:2004 | |
| 43 | Water, Water intended for human consumption | Count of faecal streptococci (Enterococci) | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 44 | Water, Water intended for human consumption | Colour Range (5 – 30) mg/l Pt |
Visual method | PN-EN ISO 7887:2012 p. D +Ap1:2015 | |
| 45 | Water, Water intended for human consumption | Turbidity Range (0,1 – 400) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 46 | Water, Water intended for human consumption | Free chlorine concentration Range (0,02 – 1,0) mg/l |
Colorimetric method | PB/PBW/01/2025 Edycja I z dnia 05.05.2025 na podstawie metodyki producenta testu | |
| 47 | Water, Water intended for human consumption | Aluminium concentration Range (20 – 400) μg/l |
Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN ISO 15586:2005 | |
| 48 | Water, Water intended for human consumption | Presence of foreign odour | Qualitative method | PN-EN 1622:2006 | |
| 49 | Water, Water intended for human consumption | Odour threshold number TON Range 1 |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 50 | Water, Water intended for human consumption | Presence of foreign taste | Qualitative method | PN-EN 1622:2006 | |
| 51 | Water, Water intended for human consumption | Taste threshold number TFN Range 1 |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 52 | Water, Water intended for human consumption | Clostridium perfringens bacteria count including spores | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 53 | Water, Water intended for human consumption | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 54 | Water, Water intended for human consumption | Count of bacteria of the genus Legionella Matrix A Procedure 5 (medium BCYE), Procedure 7 (medium GVPC) Matrix B Procedure 7 (medium GVPC) |
Membrane filtration method | PN-EN ISO 11731:2017-08+Ap1:2019-12 | |
Reference standards (46)
+A1:2017-04
+Ap1:2010+Ap2:2010
4.4.3, 4.4.5, 4.4.6.
9.4
PB/PBW/01/2025 Edycja I z dnia 05.05.2025 na podstawie metodyki producenta testu
PB/PBW/02/2025 Edycja I z dnia 05.05.2025 PB/PBW/02/2025 Edycja I z dnia 05.05.2025
PN ISO15705:2005
PN-73/C-04576/14
PN-77/C-04584
PN-79/C-04566/10
PN-82/C-04576/08
PN-EN 1622:2006
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 6222:2004
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08+Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 15586:2005
PN-EN ISO 16266:2009
PN-EN ISO 1899-2:2002
PN-EN ISO 19458:2007 z wył. pkt.
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, 9.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 pkt.4
PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt.7
PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p. D +Ap1:2015
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 6439:1994 metoda B
PN-ISO 9297:1994
z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6,