🇵🇱 SĄDECKIE WODOCIĄGI Sp. z o.o. PL

PCA AB 980 • Nowy Sącz, Poland • 54 methods

Water & wastewaterMicrobiology

SĄDECKIE WODOCIĄGI Sp. z o.o. is a laboratory accredited by PCA under number AB 980 (Nowy Sącz, Poland). Its accreditation scope covers 54 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Water, Water intended for human consumption, Wastewater, Wastewater, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 980
  • Methods in scope: 54
  • Types of test objects: 8
  • Techniques used: 17
  • City: Nowy Sącz, Poland
Accreditation number
AB 980
Accreditation body
PCA
Address
LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. Wincentego Pola 22, 33-300 Nowy Sącz
City
Nowy Sącz, Poland

What this laboratory tests (8)

Analytical techniques used (17)

Accreditation scope — test methods (54)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
2 Wastewater Temperature
Range (1,0 – 40,0) °C
PN-ISO 5667-10:2021-11 | PN-77/C-04584
3 Rainwater, snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11 | PN-77/C-04584
4 Rainwater, snowmelt water Temperature
Range (1,0 – 40,0) °C
PN-ISO 5667-10:2021-11 | PN-77/C-04584
5 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
6 Water intended for human consumption Coliform bacteria count PN-EN ISO 9308-1:2014-12 +A1:2017-04 | PN-EN ISO 9308-1:2014-12
7 Water intended for human consumption Membrane filtration method +A1:2017-04
8 Water intended for human consumption Escherichia coli count Membrane filtration method +A1:2017-04
9 Water Sampling for testing PN-EN ISO 19458:2007 z wył. pkt.
10 Water intended for human consumption microbiological 4.4.3, 4.4.5, 4.4.6.
11 Surface water Sampling for testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, 9.4 | PN-77/C-04584 | PN-EN ISO 5667-6:2016-12
12 Surface water chemical and physical (including z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6,
13 Surface water sensory) 9.4
14 Surface water Temperature
Range (1,0 – 40,0) °C
PN-77/C-04584
15 Wastewater Ammonium nitrogen concentration
Range (1 – 200) mg/I
Titrimetric method PN-ISO 5664:2002
16 Wastewater Kjeldahl nitrogen concentration
Range (2,0 – 500) mg/l
Titrimetric method PN-EN 25663:2001
17 Wastewater Chemical oxygen demand
COD Range (30 – 6000) mg/l O2
Titrimetric method PN-ISO 6060:2006
18 Wastewater Biochemical oxygen demand
BOD5 Range (3 – 2000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
19 Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
20 Wastewater Electrical conductivity
Range (100 – 3900) μS/cm
Conductometric method PN-EN 27888:1999
21 Water Biochemical oxygen demand – BOD5
Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN ISO 1899-2:2002
22 Water Chemical oxygen demand - COD
Range (2,0 – 40) mg/l O2
Spectrophotometric method PN ISO15705:2005
23 Water, Wastewater Phenol index
Range (0,005 – 1,0) mg/l
Spectrophotometric method PN-ISO 6439:1994 metoda B
24 Water, Wastewater Substances extractable with petroleum ether
Range (2,0 – 200) mg/l
Gravimetric method PB/PBW/02/2025 Edycja I z dnia 05.05.2025 PB/PBW/02/2025 Edycja I z dnia 05.05.2025
25 Water, Wastewater Sulfate concentration
Range ( 5,0-200) mg/l
Turbidimetric method PN-79/C-04566/10
26 Water, Water intended for human consumption, Wastewater Nitrate nitrogen concentration
Range (0,2 – 50,0) mg/l
PN-82/C-04576/08
27 Water, Water intended for human consumption, Wastewater Nitrate concentration
Range (0,88 – 220,0) mg/l
Spectrophotometric method PN-82/C-04576/08
28 Water, Water intended for human consumption, Wastewater Nitrite nitrogen concentration
Range (0,01 – 0,20) mg/l
PN-EN 26777:1999
29 Water, Water intended for human consumption, Wastewater Nitrite concentration
Range (0,04 – 0,80) mg/l
Spectrophotometric method PN-EN 26777:1999
30 Water, Water intended for human consumption, Wastewater Chloride concentration
Range (5,0 – 300) mg/l
Titrimetric method PN-ISO 9297:1994
31 Water, Water intended for human consumption, Wastewater Orthophosphate concentration PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.4
32 Water, Water intended for human consumption, Wastewater
Range (0,04 – 0,2) mg/l
Spectrophotometric method +Ap1:2010+Ap2:2010
33 Water, Water intended for human consumption, Wastewater Total phosphorus concentration PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.7
34 Water, Water intended for human consumption, Wastewater
Range (0,04 – 18,0) mg/l
Spectrophotometric method +Ap1:2010+Ap2:2010
35 Water, Water intended for human consumption, Wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
36 Water, Water intended for human consumption, Wastewater Total suspended solids (TSS)
Range (2,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
37 Water, Water intended for human consumption Electrical conductivity
Range (84 – 3900) μS/cm
Conductometric method PN-EN 27888:1999
38 Water, Water intended for human consumption Calcium concentration
Range (2 – 300) mg/l
Titrimetric method PN-ISO 6058:1999
39 Water, Water intended for human consumption Total hardness (total calcium and magnesium concentration)
Range (10 – 700) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
40 Water, Water intended for human consumption Total iron concentration
Range (0,050 – 1,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
41 Water, Water intended for human consumption Total count of microorganisms at 22 ± 2°C after 72 h Plate method (pour plate) PN-EN 6222:2004
42 Water, Water intended for human consumption Total count of microorganisms at 36 ± 2°C after 48 h Plate method (pour plate) PN-EN 6222:2004
43 Water, Water intended for human consumption Count of faecal streptococci (Enterococci) Membrane filtration method PN-EN ISO 7899-2:2004
44 Water, Water intended for human consumption Colour
Range (5 – 30) mg/l Pt
Visual method PN-EN ISO 7887:2012 p. D +Ap1:2015
45 Water, Water intended for human consumption Turbidity
Range (0,1 – 400) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
46 Water, Water intended for human consumption Free chlorine concentration
Range (0,02 – 1,0) mg/l
Colorimetric method PB/PBW/01/2025 Edycja I z dnia 05.05.2025 na podstawie metodyki producenta testu
47 Water, Water intended for human consumption Aluminium concentration
Range (20 – 400) μg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
48 Water, Water intended for human consumption Presence of foreign odour Qualitative method PN-EN 1622:2006
49 Water, Water intended for human consumption Odour threshold number TON
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
50 Water, Water intended for human consumption Presence of foreign taste Qualitative method PN-EN 1622:2006
51 Water, Water intended for human consumption Taste threshold number TFN
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
52 Water, Water intended for human consumption Clostridium perfringens bacteria count including spores Membrane filtration method PN-EN ISO 14189:2016-10
53 Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
54 Water, Water intended for human consumption Count of bacteria of the genus Legionella
Matrix A Procedure 5 (medium BCYE), Procedure 7 (medium GVPC) Matrix B Procedure 7 (medium GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08+Ap1:2019-12

Reference standards (46)

+A1:2017-04
+Ap1:2010+Ap2:2010
4.4.3, 4.4.5, 4.4.6.
9.4
PB/PBW/01/2025 Edycja I z dnia 05.05.2025 na podstawie metodyki producenta testu
PB/PBW/02/2025 Edycja I z dnia 05.05.2025 PB/PBW/02/2025 Edycja I z dnia 05.05.2025
PN ISO15705:2005
PN-73/C-04576/14
PN-77/C-04584
PN-79/C-04566/10
PN-82/C-04576/08
PN-EN 1622:2006
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 6222:2004
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08+Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 15586:2005
PN-EN ISO 16266:2009
PN-EN ISO 1899-2:2002
PN-EN ISO 19458:2007 z wył. pkt.
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, 9.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 pkt.4
PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt.7
PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p. D +Ap1:2015
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 6439:1994 metoda B
PN-ISO 9297:1994
z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6,