{"lab":{"_id":"69ad52a3de79e566650fb4ee","accr_number":"AB 980","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. Wincentego Pola 22, 33-300 Nowy Sącz","categories":["water","microbiology"],"city":"Nowy Sącz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":54,"name":"SĄDECKIE WODOCIĄGI Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_980.pdf"],"scope_summary":"","search_text":"sądeckie wodociągi sp. z o.o. laboratorium badania wody i ścieków, ul. wincentego pola 22, 33-300 nowy sącz water other microbiology pharma electronics automotive","status":"active","updated_at":"2026-03-08T14:51:52.158Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:52.158Z","email_confidence":"high","email_mx":true,"email_source":"https://swns.pl/Dane-kontaktowe","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"Q/28","pl":"Badania sensoryczne wody do spożycia przez ludzi","en":"Sensory tests of drinking water"},{"codes":"Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody","en":"Sensory tests and sampling of water"}],"issue":{"no":"19","date":"06.02.2026"},"parse_date":"2026-07-20T07:09:56.300Z","parse_source":"script-pdfplumber","map_coord":[49.616751,20.688896],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":54,"microbiology":5},"category_scores":{"water":49.42,"microbiology":0.42},"has_zh":true},"methods":[{"_id":"6a5dc9c4f1c10c8ce826003c","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a5dc9c4f1c10c8ce826003d","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Temperatura","methodology_en":"Temperature","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) °C"}],"parameters_en":[{"name":"Range","range":"(1,0 – 40,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura\nZakres (1,0 – 40,0) °C","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Temperatura\nZakres (1,0 – 40,0) °C PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Temperatura\nZakres (1,0 – 40,0) °C PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) °C"}],"search_zh":"污水 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a5dc9c4f1c10c8ce826003e","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","test_object_en":"Rainwater, snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rainwater, snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","search_zh":"雨水、融雪水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"雨水、融雪水","technique_zh":"手工法"},{"_id":"6a5dc9c4f1c10c8ce826003f","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","test_object_en":"Rainwater, snowmelt water","methodology":"Temperatura","methodology_en":"Temperature","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) °C"}],"parameters_en":[{"name":"Range","range":"(1,0 – 40,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura\nZakres (1,0 – 40,0) °C","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe, wody roztopowe Temperatura\nZakres (1,0 – 40,0) °C PN-ISO 5667-10:2021-11 | PN-77/C-04584 Wody opadowe, wody roztopowe Temperatura\nZakres (1,0 – 40,0) °C PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rainwater, snowmelt water Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) °C"}],"search_zh":"雨水、融雪水 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"雨水、融雪水","methodology_zh":"温度"},{"_id":"6a5dc9c4f1c10c8ce8260040","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260041","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04 | PN-EN ISO 9308-1:2014-12","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04","PN-EN ISO 9308-1:2014-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli PN-EN ISO 9308-1:2014-12 +A1:2017-04 | PN-EN ISO 9308-1:2014-12 Woda do spozycia przez ludzi Liczba bakterii grupy coli PN-EN ISO 9308-1:2014-12 +A1:2017-04 | PN-EN ISO 9308-1:2014-12","categories":["water","microbiology"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Coliform bacteria count PN-EN ISO 9308-1:2014-12 +A1:2017-04 | PN-EN ISO 9308-1:2014-12","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 PN-EN ISO 9308-1:2014-12 +A1:2017-04 | PN-EN ISO 9308-1:2014-12","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260042","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"","methodology_en":null,"parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"\nMetoda filtracji membranowej","reference":"+A1:2017-04","norm_bases":["+A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi \nMetoda filtracji membranowej +A1:2017-04 Woda do spozycia przez ludzi \nMetoda filtracji membranowej +A1:2017-04","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Membrane filtration method +A1:2017-04","search_zh":"生活饮用水 膜过滤法 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260043","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"+A1:2017-04","norm_bases":["+A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej +A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej +A1:2017-04","categories":["water","microbiology"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260044","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań","methodology_en":"Sampling for testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań","reference":"PN-EN ISO 19458:2007 z wył. pkt.","norm_bases":["PN-EN ISO 19458:2007 z wył. pkt."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań PN-EN ISO 19458:2007 z wył. pkt. Woda Pobieranie probek do badan PN-EN ISO 19458:2007 z wyl. pkt.","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for testing PN-EN ISO 19458:2007 z wył. pkt.","search_zh":"水 检测采样 PN-EN ISO 19458:2007 z wył. pkt.","test_object_zh":"水","methodology_zh":"检测采样"},{"_id":"6a5dc9c4f1c10c8ce8260045","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"mikrobiologicznych","methodology_en":"microbiological","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"mikrobiologicznych","reference":"4.4.3, 4.4.5, 4.4.6.","norm_bases":["4.4.3, 4.4.5, 4.4.6."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi mikrobiologicznych 4.4.3, 4.4.5, 4.4.6. Woda do spozycia przez ludzi mikrobiologicznych 4.4.3, 4.4.5, 4.4.6.","categories":["water","microbiology"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption microbiological 4.4.3, 4.4.5, 4.4.6.","search_zh":"生活饮用水 微生物学的 4.4.3, 4.4.5, 4.4.6.","test_object_zh":"生活饮用水","methodology_zh":"微生物学的"},{"_id":"6a5dc9c4f1c10c8ce8260046","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda powierzchniowa","test_object_en":"Surface water","methodology":"Pobieranie próbek do badań","methodology_en":"Sampling for testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, 9.4 | PN-77/C-04584 | PN-EN ISO 5667-6:2016-12","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, 9.4","PN-77/C-04584","PN-EN ISO 5667-6:2016-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa Pobieranie próbek do badań PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, 9.4 | PN-77/C-04584 | PN-EN ISO 5667-6:2016-12 Woda powierzchniowa Pobieranie probek do badan PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.2, 7.3, 7.5, 7.6, 9.4 | PN-77/C-04584 | PN-EN ISO 5667-6:2016-12","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface water Sampling for testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, 9.4 | PN-77/C-04584 | PN-EN ISO 5667-6:2016-12","search_zh":"地表水 检测采样 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, 9.4 | PN-77/C-04584 | PN-EN ISO 5667-6:2016-12","test_object_zh":"地表水","methodology_zh":"检测采样"},{"_id":"6a5dc9c4f1c10c8ce8260047","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda powierzchniowa","test_object_en":"Surface water","methodology":"chemicznych i fizycznych (w tym","methodology_en":"chemical and physical (including","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"chemicznych i fizycznych (w tym","reference":"z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6,","norm_bases":["z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6,"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa chemicznych i fizycznych (w tym z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, Woda powierzchniowa chemicznych i fizycznych (w tym z wylaczeniem pkt. 7.2, 7.3, 7.5, 7.6,","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface water chemical and physical (including z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6,","search_zh":"地表水 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6,","test_object_zh":"地表水"},{"_id":"6a5dc9c4f1c10c8ce8260048","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda powierzchniowa","test_object_en":"Surface water","methodology":"sensorycznych)","methodology_en":"sensory)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"sensorycznych)","reference":"9.4","norm_bases":["9.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa sensorycznych) 9.4 Woda powierzchniowa sensorycznych) 9.4","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface water sensory) 9.4","search_zh":"地表水 9.4","test_object_zh":"地表水"},{"_id":"6a5dc9c4f1c10c8ce8260049","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda powierzchniowa","test_object_en":"Surface water","methodology":"Temperatura","methodology_en":"Temperature","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) °C"}],"parameters_en":[{"name":"Range","range":"(1,0 – 40,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura\nZakres (1,0 – 40,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa Temperatura\nZakres (1,0 – 40,0) °C PN-77/C-04584 Woda powierzchniowa Temperatura\nZakres (1,0 – 40,0) °C PN-77/C-04584","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface water Temperature Range PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) °C"}],"search_zh":"地表水 温度 范围 PN-77/C-04584","methodology_zh":"温度","test_object_zh":"地表水"},{"_id":"6a5dc9c4f1c10c8ce826004a","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(1 – 200) mg/I"}],"parameters_en":[{"name":"Range","range":"(1 – 200) mg/I"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (1 – 200) mg/I\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (1 – 200) mg/I\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (1 – 200) mg/I\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1 – 200) mg/I"}],"search_zh":"污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9c4f1c10c8ce826004b","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(2,0 – 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,0 – 500) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (2,0 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (2,0 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 500) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9c4f1c10c8ce826004c","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT"},{"name":"Zakres","range":"(30 – 6000) mg/l O2"}],"parameters_en":[{"name":"COD"},{"name":"Range","range":"(30 – 6000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (30 – 6000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (30 – 6000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (30 – 6000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand Titrimetric method COD Range PN-ISO 6060:2006","parameters_zh":[{"name":"化学需氧量（COD）"},{"name":"范围","range":"(30 – 6000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD） 滴定法 化学需氧量（COD） 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9c4f1c10c8ce826004d","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 2000) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 2000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 2000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 2000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 2000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 2000) mg/l O2"}],"search_zh":"污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a5dc9c4f1c10c8ce826004e","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"污水"},{"_id":"6a5dc9c4f1c10c8ce826004f","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(100 – 3900) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100 – 3900) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 3900) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Przewodność elektryczna właściwa\nZakres (100 – 3900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Scieki Przewodnosc elektryczna wlasciwa\nZakres (100 – 3900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 3900) μS/cm"}],"search_zh":"污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"污水"},{"_id":"6a5dc9c4f1c10c8ce8260050","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 1899-2:2002","norm_bases":["PN-EN ISO 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 1899-2:2002 Woda Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 1899-2:2002","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Biochemical oxygen demand – BOD5 Electrochemical method Range PN-EN ISO 1899-2:2002","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c4f1c10c8ce8260051","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","methodology_en":"Chemical oxygen demand - COD","parameters":[{"name":"Zakres","range":"(2,0 – 40) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(2,0 – 40) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (2,0 – 40) mg/l O2\nMetoda spektrofotometryczna","reference":"PN ISO15705:2005","norm_bases":["PN ISO15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (2,0 – 40) mg/l O2\nMetoda spektrofotometryczna PN ISO15705:2005 Woda Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (2,0 – 40) mg/l O2\nMetoda spektrofotometryczna PN ISO15705:2005","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chemical oxygen demand - COD Spectrophotometric method Range PN ISO15705:2005","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(2,0 – 40) mg/l O2"}],"search_zh":"水 化学需氧量 ChZT（COD） 分光光度法 范围 PN ISO15705:2005","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9c4f1c10c8ce8260052","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,005 – 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,005 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,005 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 metoda B","norm_bases":["PN-ISO 6439:1994 metoda B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,005 – 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B Woda, Scieki Indeks fenolowy\nZakres (0,005 – 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994 metoda B","parameters_zh":[{"name":"范围","range":"(0,005 – 1,0) mg/l"}],"search_zh":"水、污水 酚指数 分光光度法 范围 PN-ISO 6439:1994 metoda B","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"酚指数"},{"_id":"6a5dc9c4f1c10c8ce8260053","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Substancje ekstrahujące się eterem naftowym","methodology_en":"Substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(2,0 – 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 200) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Substancje ekstrahujące się eterem naftowym\nZakres (2,0 – 200) mg/l\nMetoda wagowa","reference":"PB/PBW/02/2025 Edycja I z dnia 05.05.2025 PB/PBW/02/2025 Edycja I z dnia 05.05.2025","norm_bases":["PB/PBW/02/2025 Edycja I z dnia 05.05.2025 PB/PBW/02/2025 Edycja I z dnia 05.05.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Substancje ekstrahujące się eterem naftowym\nZakres (2,0 – 200) mg/l\nMetoda wagowa PB/PBW/02/2025 Edycja I z dnia 05.05.2025 PB/PBW/02/2025 Edycja I z dnia 05.05.2025 Woda, Scieki Substancje ekstrahujace sie eterem naftowym\nZakres (2,0 – 200) mg/l\nMetoda wagowa PB/PBW/02/2025 Edycja I z dnia 05.05.2025 PB/PBW/02/2025 Edycja I z dnia 05.05.2025","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Substances extractable with petroleum ether Gravimetric method Range PB/PBW/02/2025 Edycja I z dnia 05.05.2025 PB/PBW/02/2025 Edycja I z dnia 05.05.2025","parameters_zh":[{"name":"范围","range":"(2,0 – 200) mg/l"}],"search_zh":"水、污水 石油醚可萃取物 重量法 范围 PB/PBW/02/2025 Edycja I z dnia 05.05.2025 PB/PBW/02/2025 Edycja I z dnia 05.05.2025","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"石油醚可萃取物"},{"_id":"6a5dc9c4f1c10c8ce8260054","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"( 5,0-200) mg/l"}],"parameters_en":[{"name":"Range","range":"( 5,0-200) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"technique_en":"Turbidimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres ( 5,0-200) mg/l\nMetoda turbidymetryczna","reference":"PN-79/C-04566/10","norm_bases":["PN-79/C-04566/10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres ( 5,0-200) mg/l\nMetoda turbidymetryczna PN-79/C-04566/10 Woda, Scieki Stezenie siarczanow\nZakres ( 5,0-200) mg/l\nMetoda turbidymetryczna PN-79/C-04566/10","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sulfate concentration Turbidimetric method Range PN-79/C-04566/10","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"( 5,0-200) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 浊度法 范围 PN-79/C-04566/10","test_object_zh":"水、污水","technique_zh":"浊度法"},{"_id":"6a5dc9c4f1c10c8ce8260055","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,2 – 50,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,2 – 50,0) mg/l"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,2 – 50,0) mg/l","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotanowego\nZakres (0,2 – 50,0) mg/l PN-82/C-04576/08 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu azotanowego\nZakres (0,2 – 50,0) mg/l PN-82/C-04576/08","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Nitrate nitrogen concentration Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,2 – 50,0) mg/l"}],"search_zh":"水、生活饮用水、废水 硝态氮浓度 范围 PN-82/C-04576/08","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9c4f1c10c8ce8260056","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,88 – 220,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,88 – 220,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,88 – 220,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotanów\nZakres (0,88 – 220,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotanow\nZakres (0,88 – 220,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Nitrate concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,88 – 220,0) mg/l"}],"search_zh":"水、生活饮用水、废水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9c4f1c10c8ce8260057","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,01 – 0,20) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,01 – 0,20) mg/l"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,01 – 0,20) mg/l","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotynowego\nZakres (0,01 – 0,20) mg/l PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu azotynowego\nZakres (0,01 – 0,20) mg/l PN-EN 26777:1999","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Nitrite nitrogen concentration Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 0,20) mg/l"}],"search_zh":"水、生活饮用水、废水 亚硝态氮浓度 范围 PN-EN 26777:1999","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9c4f1c10c8ce8260058","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,04 – 0,80) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 0,80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,04 – 0,80) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotynów\nZakres (0,04 – 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotynow\nZakres (0,04 – 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 0,80) mg/l"}],"search_zh":"水、生活饮用水、废水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9c4f1c10c8ce8260059","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 – 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 – 300) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie chlorków\nZakres (5,0 – 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi, Scieki Stezenie chlorkow\nZakres (5,0 – 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 300) mg/l"}],"search_zh":"水、生活饮用水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9c4f1c10c8ce826005a","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów","reference":"PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.4","norm_bases":["PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","PN-EN ISO 6878:2006 pkt.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie ortofosforanów PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.4 Woda, Woda do spozycia przez ludzi, Scieki Stezenie ortofosforanow PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.4","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Orthophosphate concentration PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.4","search_zh":"水、生活饮用水、废水 正磷酸盐浓度 PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.4","test_object_zh":"水、生活饮用水、废水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9c4f1c10c8ce826005b","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"","methodology_en":null,"parameters":[{"name":"Zakres","range":"(0,04 – 0,2) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 0,2) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"\nZakres (0,04 – 0,2) mg/l\nMetoda spektrofotometryczna","reference":"+Ap1:2010+Ap2:2010","norm_bases":["+Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki \nZakres (0,04 – 0,2) mg/l\nMetoda spektrofotometryczna +Ap1:2010+Ap2:2010 Woda, Woda do spozycia przez ludzi, Scieki \nZakres (0,04 – 0,2) mg/l\nMetoda spektrofotometryczna +Ap1:2010+Ap2:2010","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Spectrophotometric method Range +Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,04 – 0,2) mg/l"}],"search_zh":"水、生活饮用水、废水 分光光度法 范围 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9c4f1c10c8ce826005c","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego","reference":"PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.7","norm_bases":["PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010","PN-EN ISO 6878:2006 pkt.7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie fosforu ogólnego PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.7 Woda, Woda do spozycia przez ludzi, Scieki Stezenie fosforu ogolnego PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.7","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Total phosphorus concentration PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.7","methodology_zh":"总磷浓度","search_zh":"水、生活饮用水、废水 总磷浓度 PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010 | PN-EN ISO 6878:2006 pkt.7","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9c4f1c10c8ce826005d","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"","methodology_en":null,"parameters":[{"name":"Zakres","range":"(0,04 – 18,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 18,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"\nZakres (0,04 – 18,0) mg/l\nMetoda spektrofotometryczna","reference":"+Ap1:2010+Ap2:2010","norm_bases":["+Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki \nZakres (0,04 – 18,0) mg/l\nMetoda spektrofotometryczna +Ap1:2010+Ap2:2010 Woda, Woda do spozycia przez ludzi, Scieki \nZakres (0,04 – 18,0) mg/l\nMetoda spektrofotometryczna +Ap1:2010+Ap2:2010","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Spectrophotometric method Range +Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,04 – 18,0) mg/l"}],"search_zh":"水、生活饮用水、废水 分光光度法 范围 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9c4f1c10c8ce826005e","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9c4f1c10c8ce826005f","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Woda do spozycia przez ludzi, Scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"水、生活饮用水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9c4f1c10c8ce8260060","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(84 – 3900) μS/cm"}],"parameters_en":[{"name":"Range","range":"(84 – 3900) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (84 – 3900) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (84 – 3900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (84 – 3900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(84 – 3900) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260061","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(2 – 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(2 – 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (2 – 300) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wapnia\nZakres (2 – 300) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, Woda do spozycia przez ludzi Stezenie wapnia\nZakres (2 – 300) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(2 – 300) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a5dc9c4f1c10c8ce8260062","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Twardość ogólna (sumaryczne stężenie wapnia i magnezu)","methodology_en":"Total hardness (total calcium and magnesium concentration)","parameters":[{"name":"Zakres","range":"(10 – 700) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(10 – 700) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Twardość ogólna (sumaryczne stężenie wapnia i magnezu)\nZakres (10 – 700) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Twardość ogólna (sumaryczne stężenie wapnia i magnezu)\nZakres (10 – 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Twardosc ogolna (sumaryczne stezenie wapnia i magnezu)\nZakres (10 – 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total hardness (total calcium and magnesium concentration) Titrimetric method Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(10 – 700) mg/l CaCO3"}],"search_zh":"水、生活饮用水 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260063","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,050 – 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,050 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,050 – 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,050 – 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260064","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 22 ± 2°C po 72 h","methodology_en":"Total count of microorganisms at 22 ± 2°C after 72 h","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22 ± 2°C po 72 h\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN 6222:2004","norm_bases":["PN-EN 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22 ± 2°C po 72 h\nMetoda płytkowa (posiew wgłębny) PN-EN 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22 ± 2°C po 72 h\nMetoda plytkowa (posiew wglebny) PN-EN 6222:2004","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total count of microorganisms at 22 ± 2°C after 72 h Plate method (pour plate) PN-EN 6222:2004","search_zh":"水、生活饮用水 平板法（倾注培养） PN-EN 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260065","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 36 ± 2°C po 48 h","methodology_en":"Total count of microorganisms at 36 ± 2°C after 48 h","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36 ± 2°C po 48 h\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN 6222:2004","norm_bases":["PN-EN 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 36 ± 2°C po 48 h\nMetoda płytkowa (posiew wgłębny) PN-EN 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 36 ± 2°C po 48 h\nMetoda plytkowa (posiew wglebny) PN-EN 6222:2004","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total count of microorganisms at 36 ± 2°C after 48 h Plate method (pour plate) PN-EN 6222:2004","search_zh":"水、生活饮用水 平板法（倾注培养） PN-EN 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260066","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba paciorkowców kałowych (Enterokoki)","methodology_en":"Count of faecal streptococci (Enterococci)","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba paciorkowców kałowych (Enterokoki)\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba paciorkowców kałowych (Enterokoki)\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba paciorkowcow kalowych (Enterokoki)\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Count of faecal streptococci (Enterococci) Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水、生活饮用水 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260067","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 – 30) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 – 30) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 – 30) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 p. D +Ap1:2015","norm_bases":["PN-EN ISO 7887:2012 p. D +Ap1:2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5 – 30) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 p. D +Ap1:2015 Woda, Woda do spozycia przez ludzi Barwa\nZakres (5 – 30) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 p. D +Ap1:2015","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Colour Visual method Range PN-EN ISO 7887:2012 p. D +Ap1:2015","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 30) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 范围 PN-EN ISO 7887:2012 p. D +Ap1:2015","technique_zh":"目视法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260068","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,1 – 400) NTU"}],"parameters_en":[{"name":"Range","range":"(0,1 – 400) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,1 – 400) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,1 – 400) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,1 – 400) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,1 – 400) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260069","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie chloru wolnego","methodology_en":"Free chlorine concentration","parameters":[{"name":"Zakres","range":"(0,02 – 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 – 1,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego\nZakres (0,02 – 1,0) mg/l\nMetoda kolorymetryczna","reference":"PB/PBW/01/2025 Edycja I z dnia 05.05.2025 na podstawie metodyki producenta testu","norm_bases":["PB/PBW/01/2025 Edycja I z dnia 05.05.2025 na podstawie metodyki producenta testu"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,02 – 1,0) mg/l\nMetoda kolorymetryczna PB/PBW/01/2025 Edycja I z dnia 05.05.2025 na podstawie metodyki producenta testu Woda, Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,02 – 1,0) mg/l\nMetoda kolorymetryczna PB/PBW/01/2025 Edycja I z dnia 05.05.2025 na podstawie metodyki producenta testu","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Free chlorine concentration Colorimetric method Range PB/PBW/01/2025 Edycja I z dnia 05.05.2025 na podstawie metodyki producenta testu","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 游离氯浓度 比色法 范围 PB/PBW/01/2025 Edycja I z dnia 05.05.2025 na podstawie metodyki producenta testu","technique_zh":"比色法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce826006a","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie glinu","methodology_en":"Aluminium concentration","parameters":[{"name":"Zakres","range":"(20 – 400) μg/l"}],"parameters_en":[{"name":"Range","range":"(20 – 400) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie glinu\nZakres (20 – 400) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie glinu\nZakres (20 – 400) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Woda do spozycia przez ludzi Stezenie glinu\nZakres (20 – 400) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Aluminium concentration Electrothermal atomization atomic absorption spectrometry (ETAAS) Range PN-EN ISO 15586:2005","parameters_zh":[{"name":"范围","range":"(20 – 400) μg/l"}],"search_zh":"水、生活饮用水 铝浓度 电热原子化原子吸收光谱法（ETAAS） 范围 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"铝浓度"},{"_id":"6a5dc9c4f1c10c8ce826006b","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Obecność obcego zapachu","methodology_en":"Presence of foreign odour","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa","techniques":["Metoda jakościowa"],"technique_en":"Qualitative method","computed":[],"computed_en":[],"activity":"Obecność obcego zapachu\nMetoda jakościowa","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Obecność obcego zapachu\nMetoda jakościowa PN-EN 1622:2006 Woda, Woda do spozycia przez ludzi Obecnosc obcego zapachu\nMetoda jakosciowa PN-EN 1622:2006","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Presence of foreign odour Qualitative method PN-EN 1622:2006","search_zh":"水、生活饮用水 异味的检出 定性法 PN-EN 1622:2006","test_object_zh":"水、生活饮用水","technique_zh":"定性法","methodology_zh":"异味的检出"},{"_id":"6a5dc9c4f1c10c8ce826006c","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba progowa zapachu TON","methodology_en":"Odour threshold number TON","parameters":[{"name":"Zakres","range":"1"}],"parameters_en":[{"name":"Range","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"technique_en":"Simplified method, paired, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda, Woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Odour threshold number TON Simplified method, paired, non-forced choice Range PN-EN 1622:2006","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"水、生活饮用水 嗅阈值 TON 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"水、生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"嗅阈值 TON"},{"_id":"6a5dc9c4f1c10c8ce826006d","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Obecność obcego smaku","methodology_en":"Presence of foreign taste","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa","techniques":["Metoda jakościowa"],"technique_en":"Qualitative method","computed":[],"computed_en":[],"activity":"Obecność obcego smaku\nMetoda jakościowa","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Obecność obcego smaku\nMetoda jakościowa PN-EN 1622:2006 Woda, Woda do spozycia przez ludzi Obecnosc obcego smaku\nMetoda jakosciowa PN-EN 1622:2006","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Presence of foreign taste Qualitative method PN-EN 1622:2006","search_zh":"水、生活饮用水 异味（口感）的检出 定性法 PN-EN 1622:2006","test_object_zh":"水、生活饮用水","technique_zh":"定性法","methodology_zh":"异味（口感）的检出"},{"_id":"6a5dc9c4f1c10c8ce826006e","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba progowa smaku TFN","methodology_en":"Taste threshold number TFN","parameters":[{"name":"Zakres","range":"1"}],"parameters_en":[{"name":"Range","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"technique_en":"Simplified method, paired, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda, Woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Taste threshold number TFN Simplified method, paired, non-forced choice Range PN-EN 1622:2006","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"水、生活饮用水 味阈值 TFN 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"水、生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"味阈值 TFN"},{"_id":"6a5dc9c4f1c10c8ce826006f","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii Clostridium perfringens łącznie z przetrwalnikami","methodology_en":"Clostridium perfringens bacteria count including spores","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia przez ludzi Liczba bakterii Clostridium perfringens lacznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water","microbiology"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Clostridium perfringens bacteria count including spores Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水、生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a5dc9c4f1c10c8ce8260070","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce8260071","lab_id":"69ad52a3de79e566650fb4ee","country":"PL","accr_number":"AB 980","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A Procedura 5 (pożywka BCYE), Procedura 7 (pożywka GVPC) Matryca B Procedura 7 (pożywka GVPC)"}],"parameters_en":[{"name":"Matrix A Procedure 5 (medium BCYE), Procedure 7 (medium GVPC) Matrix B Procedure 7 (medium GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka BCYE), Procedura 7 (pożywka GVPC) Matryca B Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08+Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08+Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka BCYE), Procedura 7 (pożywka GVPC) Matryca B Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08+Ap1:2019-12 Woda, Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pozywka BCYE), Procedura 7 (pozywka GVPC) Matryca B Procedura 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08+Ap1:2019-12","categories":["microbiology","water"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium BCYE), Procedure 7 (medium GVPC) Matrix B Procedure 7 (medium GVPC) PN-EN ISO 11731:2017-08+Ap1:2019-12","search_zh":"水、生活饮用水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08+Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"军团菌属细菌计数"}],"has_pdf":true}