🇵🇱 ZAKŁAD USŁUGOWY BADAŃ, POMIARÓW PL
Environment
ZAKŁAD USŁUGOWY BADAŃ, POMIARÓW is a laboratory accredited by PCA under number AB 947 (Kielce, Poland). Its accreditation scope covers 20 test methods in the following areas: Environment. Test objects include: Waste gases, General environment - noise from installations, equipment and indus…, Waste gas cleaning installations. Most frequently used techniques: Gravimetric method, Aspiration method using activated carbon, Aspiration method using activated carbon and silica gel.
At a glance
- Accreditation number: PCA AB 947
- Methods in scope: 20
- Types of test objects: 3
- Techniques used: 7
- City: Kielce, Poland
- Accreditation number
- AB 947
- Accreditation body
- PCA
- Address
- I OPRACOWAŃ OCHRONY ŚRODOWISKA, K. Borowiec, R. Mazur s.c., ul. Króla Władysława Jagiełły 9/7, 25-634 Kielce, LABORATORIUM, ul. Wesoła 26, 25-305 Kielce
- City
- Kielce, Poland
What this laboratory tests (3)
- Waste gases — 16 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
- Waste gas cleaning installations — 2 methods
Analytical techniques used (7)
- Gravimetric method — 3 methods
- Aspiration method using activated carbon — 1 method
- Aspiration method using activated carbon and silica gel — 1 method
- Continuous flame ionization detection method FID — 1 method
- Direct measurement method — 1 method
- Non-dispersive infrared spectrometry (NDIR); Electrochemical method — 1 method
- Stagnation pressure method — 1 method
Accreditation scope — test methods (20)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Waste gases | Gas volume flow rate for dynamic pressures >10 Pa | Stagnation pressure method | PN-Z-04030-7:1994 | |
| 2 | Waste gases | Sampling for determination of dust concentration | PN-Z-04030-7:1994 | ||
| 3 | Waste gases | Dust concentration Range (0,001 - 100) g/m3 |
Gravimetric method | PN-Z-04030-7:1994 | |
| 4 | Waste gases | Dust emission (calculated) | PN-Z-04030-7:1994 | ||
| 5 | Waste gases | Concentration of carbon monoxide, carbon dioxide, sulphur dioxide, nitrogen monoxide and nitrogen dioxide. CO (7,0 - 25000) mg/m3 CO2 (0,2 - 30) % SO2 (4,0 - 1400) mg/ m3 NOX (5,0 - 400) mg/m3 NO2 (2,0 - 50) mg/m3 O2 (0,9 - 21,0) % |
Non-dispersive infrared spectrometry (NDIR); Electrochemical method | PN-ISO 10396:2001 | |
| 6 | Waste gases | Emission of CO, CO2, , NOX (NO and NO2 calculated as NO2), SO2 (calculated) | PN-ISO 10396:2001 | ||
| 7 | Waste gases | Sampling for determination of concentrations of organic compounds | Aspiration method using activated carbon and silica gel | PN-Z-04008-4:1999 | |
| 8 | Waste gases | Emission of organic compounds (calculated) | PN-Z-04008-4:1999 | ||
| 9 | Waste gases | Sampling for determination of the concentrations of individual gaseous organic compounds. | Aspiration method using activated carbon | PN-EN 13649:2005 | |
| 10 | Waste gases | Emission of individual gaseous organic compounds (calculated) | PN-EN 13649:2005 | ||
| 11 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (2 - 1000) mg/m3 |
Continuous flame ionization detection method FID | PN-EN 12619:2013 | |
| 12 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) | PN-EN 12619:2013 | ||
| 13 | Waste gases | Dust sampling for particle size determination | PN-Z-04030-7:1994 | ||
| 14 | Waste gases | Sampling for the determination of PM 10, PM 2,5 dust concentration | PN-EN ISO 23210:2010 | PN-Z-04030-7:1994 | ||
| 15 | Waste gases | PM 10, PM 2,5 dust concentration PM 10 (0,8 - 40) mg/m3 PM 2,5 (0,4 - 40) mg/m3 |
Gravimetric method | PN-EN ISO 23210:2010 | PN-Z-04030-7:1994 | |
| 16 | Waste gases | Emission of PM 10, PM 2,5 dust (calculated) | PN-EN ISO 23210:2010 | PN-Z-04030-7:1994 | ||
| 17 | Waste gas cleaning installations | Dust concentration Range (0,001 - 100) g/m3 |
Gravimetric method | PN-M-34129:1987 – metoda A | PN-Z-04030-7:1994 | |
| 18 | Waste gas cleaning installations | Dust removal efficiency (calculated) | PN-M-34129:1987 – metoda A | PN-Z-04030-7:1994 | ||
| 19 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25 - 130) dB |
Direct measurement method | Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem pkt. E.I.1 oraz pkt. F | |
| 20 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem pkt. E.I.1 oraz pkt. F | ||
Reference standards (8)
PN-EN 12619:2013
PN-EN 13649:2005
PN-EN ISO 23210:2010
PN-ISO 10396:2001
PN-M-34129:1987 – metoda A
PN-Z-04008-4:1999
PN-Z-04030-7:1994
Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem pkt. E.I.1 oraz pkt. F