🇵🇱 ELBLĄSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI PL
Water & wastewaterMicrobiology
ELBLĄSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 941 (Elbląg, Poland). Its accreditation scope covers 23 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Wastewater, Rainwater, snowmelt water, Wastewater, rainwater, snowmelt water. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Electrochemical method.
At a glance
- Accreditation number: PCA AB 941
- Methods in scope: 23
- Types of test objects: 4
- Techniques used: 10
- City: Elbląg, Poland
- Accreditation number
- AB 941
- Accreditation body
- PCA
- Address
- Spółka z ograniczoną odpowiedzialnością, ul. Rawska 2-4, 82-300 Elbląg
- City
- Elbląg, Poland
What this laboratory tests (4)
- Water, water intended for human consumption — 12 methods
- Wastewater — 9 methods
- Rainwater, snowmelt water — 1 method
- Wastewater, rainwater, snowmelt water — 1 method
Analytical techniques used (10)
- Spectrophotometric method — 5 methods
- Membrane filtration method — 3 methods
- Electrochemical method — 2 methods
- Gravimetric method — 2 methods
- Plate method (pour plate) — 2 methods
- Potentiometric method — 2 methods
- Titrimetric method — 2 methods
- Conductometric method — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
Accreditation scope — test methods (23)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Wastewater | pH Range 4,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 2 | Wastewater | Biochemical oxygen demand BOD5 Range (4 – 3000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 3 | Wastewater | Biochemical oxygen demand BOD5 Range (0,50 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 4 | Wastewater | Chemical oxygen demand COD Range (30 – 60000) mg/l O2 |
Titrimetric method | PN-ISO 6060:2006 | |
| 5 | Wastewater | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007 + Ap1:2007 | |
| 6 | Wastewater | Total nitrogen concentration Range (0,50 – 1500) mg/l |
Spectrophotometric method | PB – 11/2012 wydanie 1 z dnia 24.05.2012 w oparciu o testy MERCK nr 1.00613.0001 i 1.14763.0001 | |
| 7 | Wastewater | Total phosphorus concentration Range (0,10 – 50) mg/l |
Spectrophotometric method | PB – 1/2020 wydanie 1 z dnia 02.01.2020 w oparciu o testy MERCK nr 1.14543.0001 i 1.14729.0001 | |
| 8 | Wastewater | Total iron concentration Range (0,50 – 10,0) mg/l |
Spectrophotometric method | PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 + Ap1:2016-06 | |
| 9 | Wastewater | Chloride concentration Range (10 – 1000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 10 | Rainwater, snowmelt water | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007 + Ap1:2007 | |
| 11 | Wastewater, rainwater, snowmelt water | Sampling for physical and chemical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 12 | Water, water intended for human consumption | Turbidity Range (0,10 – 100) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 13 | Water, water intended for human consumption | Colour Range (5 – 100) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 | |
| 14 | Water, water intended for human consumption | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 15 | Water, water intended for human consumption | Electrical conductivity Range (147 – 5000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 16 | Water, water intended for human consumption | Total iron concentration Range (20 – 20000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 +Ap1:2016-06 | |
| 17 | Water, water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 18 | Water, water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 19 | Water, water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 20 | Water, water intended for human consumption | Total viable count at 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 21 | Water, water intended for human consumption | Total viable count at 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 22 | Water, water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 23 | Water, water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6 | ||
Reference standards (19)
PB – 1/2020 wydanie 1 z dnia 02.01.2020 w oparciu o testy MERCK nr 1.14543.0001 i 1.14729.0001
PB – 11/2012 wydanie 1 z dnia 24.05.2012 w oparciu o testy MERCK nr 1.00613.0001 i 1.14763.0001
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6060:2006
PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 + Ap1:2016-06
PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 +Ap1:2016-06
PN-ISO 9297:1994