{"lab":{"_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","address":"Spółka z ograniczoną odpowiedzialnością, ul. Rawska 2-4, 82-300 Elbląg","categories":["water","microbiology"],"city":"Elbląg","imported_at":"2026-03-08T10:42:43.265Z","methods_count":23,"name":"ELBLĄSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI","parse_status":"parsed","parse_version":2,"pdf_files":["AB_941.pdf"],"scope_summary":"","search_text":"elbląskie przedsiębiorstwo wodociągów i kanalizacji spółka z ograniczoną odpowiedzialnością, ul. rawska 2-4, 82-300 elbląg other water pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:51:50.416Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:50.416Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20941,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/29/P C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"}],"issue":{"no":"16","date":"19.09.2024"},"parse_date":"2026-07-20T07:09:55.529Z","parse_source":"script-pdfplumber","map_coord":[54.144966,19.442749],"map_geo":"nominatim-street","has_zh":true,"has_en":true,"category_counts":{"water":23,"microbiology":3},"category_scores":{"water":20.35,"microbiology":0.35}},"methods":[{"_id":"6a5dc9c3f1c10c8ce825fd78","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 12,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水","search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012"},{"_id":"6a5dc9c3f1c10c8ce825fd79","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu BZT5","methodology_en":"Biochemical oxygen demand BOD5","parameters":[{"name":"Zakres","range":"(4 – 3000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(4 – 3000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (4 – 3000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (4 – 3000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (4 – 3000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"生化需氧量 BZT5（BOD5）","parameters_zh":[{"name":"范围","range":"(4 – 3000) mg/l O2"}],"search_zh":"污水 生化需氧量 BZT5（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","search_en":"Wastewater Biochemical oxygen demand BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12"},{"_id":"6a5dc9c3f1c10c8ce825fd7a","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu BZT5","methodology_en":"Biochemical oxygen demand BOD5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"生化需氧量 BZT5（BOD5）","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"污水 生化需氧量 BZT5（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水","search_en":"Wastewater Biochemical oxygen demand BOD5 Electrochemical method Range PN-EN 1899-2:2002"},{"_id":"6a5dc9c3f1c10c8ce825fd7b","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu ChZT","methodology_en":"Chemical oxygen demand COD","parameters":[{"name":"Zakres","range":"(30 – 60000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(30 – 60000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT\nZakres (30 – 60000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu ChZT\nZakres (30 – 60000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu ChZT\nZakres (30 – 60000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(30 – 60000) mg/l O2"}],"search_zh":"污水 化学需氧量 ChZT（COD） 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水","search_en":"Wastewater Chemical oxygen demand COD Titrimetric method Range PN-ISO 6060:2006"},{"_id":"6a5dc9c3f1c10c8ce825fd7c","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"污水","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 + Ap1:2007"},{"_id":"6a5dc9c3f1c10c8ce825fd7d","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,50 – 1500) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,50 – 1500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (0,50 – 1500) mg/l\nMetoda spektrofotometryczna","reference":"PB – 11/2012 wydanie 1 z dnia 24.05.2012 w oparciu o testy MERCK nr 1.00613.0001 i 1.14763.0001","norm_bases":["PB – 11/2012 wydanie 1 z dnia 24.05.2012 w oparciu o testy MERCK nr 1.00613.0001 i 1.14763.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (0,50 – 1500) mg/l\nMetoda spektrofotometryczna PB – 11/2012 wydanie 1 z dnia 24.05.2012 w oparciu o testy MERCK nr 1.00613.0001 i 1.14763.0001 Scieki Stezenie azotu ogolnego\nZakres (0,50 – 1500) mg/l\nMetoda spektrofotometryczna PB – 11/2012 wydanie 1 z dnia 24.05.2012 w oparciu o testy MERCK nr 1.00613.0001 i 1.14763.0001","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 1500) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 范围 PB – 11/2012 wydanie 1 z dnia 24.05.2012 w oparciu o testy MERCK nr 1.00613.0001 i 1.14763.0001","technique_zh":"分光光度法","test_object_zh":"污水","search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Range PB – 11/2012 wydanie 1 z dnia 24.05.2012 w oparciu o testy MERCK nr 1.00613.0001 i 1.14763.0001"},{"_id":"6a5dc9c3f1c10c8ce825fd7e","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PB – 1/2020 wydanie 1 z dnia 02.01.2020 w oparciu o testy MERCK nr 1.14543.0001 i 1.14729.0001","norm_bases":["PB – 1/2020 wydanie 1 z dnia 02.01.2020 w oparciu o testy MERCK nr 1.14543.0001 i 1.14729.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,10 – 50) mg/l\nMetoda spektrofotometryczna PB – 1/2020 wydanie 1 z dnia 02.01.2020 w oparciu o testy MERCK nr 1.14543.0001 i 1.14729.0001 Scieki Stezenie fosforu ogolnego\nZakres (0,10 – 50) mg/l\nMetoda spektrofotometryczna PB – 1/2020 wydanie 1 z dnia 02.01.2020 w oparciu o testy MERCK nr 1.14543.0001 i 1.14729.0001","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PB – 1/2020 wydanie 1 z dnia 02.01.2020 w oparciu o testy MERCK nr 1.14543.0001 i 1.14729.0001","technique_zh":"分光光度法","test_object_zh":"污水","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PB – 1/2020 wydanie 1 z dnia 02.01.2020 w oparciu o testy MERCK nr 1.14543.0001 i 1.14729.0001"},{"_id":"6a5dc9c3f1c10c8ce825fd7f","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,50 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,50 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 + Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 + Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (0,50 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 + Ap1:2016-06 Scieki Stezenie zelaza ogolnego\nZakres (0,50 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 z wylaczeniem pkt 7.1.2 + Ap1:2016-06","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 + Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"污水","search_en":"Wastewater Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 + Ap1:2016-06"},{"_id":"6a5dc9c3f1c10c8ce825fd80","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (10 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków\nZakres (10 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (10 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水","search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994"},{"_id":"6a5dc9c3f1c10c8ce825fd81","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","test_object_en":"Rainwater, snowmelt water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe, wody roztopowe Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Wody opadowe, wody roztopowe Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"雨水、融雪水 总悬浮物 重量法 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"雨水、融雪水","search_en":"Rainwater, snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 + Ap1:2007"},{"_id":"6a5dc9c3f1c10c8ce825fd82","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Ścieki, wody opadowe, wody roztopowe","test_object_en":"Wastewater, rainwater, snowmelt water","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","methodology_en":"Sampling for physical and chemical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, wody opadowe, wody roztopowe Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki, wody opadowe, wody roztopowe Pobieranie probek do badan fizycznych i chemicznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"物理与化学检测用样品采集","search_zh":"污水、雨水、融雪水 物理与化学检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水、雨水、融雪水","search_en":"Wastewater, rainwater, snowmelt water Sampling for physical and chemical testing Manual method; Automatic method PN-ISO 5667-10:2021-11"},{"_id":"6a5dc9c3f1c10c8ce825fd83","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水","search_en":"Water, water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09"},{"_id":"6a5dc9c3f1c10c8ce825fd84","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 – 100) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 – 100) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 Woda, woda do spozycia przez ludzi Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 100) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","search_en":"Water, water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06"},{"_id":"6a5dc9c3f1c10c8ce825fd85","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水","search_en":"Water, water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012"},{"_id":"6a5dc9c3f1c10c8ce825fd86","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(147 – 5000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(147 – 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (147 – 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (147 – 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (147 – 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(147 – 5000) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水","search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999"},{"_id":"6a5dc9c3f1c10c8ce825fd87","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(20 – 20000) μg/l"}],"parameters_en":[{"name":"Range","range":"(20 – 20000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (20 – 20000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 +Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 +Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (20 – 20000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 +Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (20 – 20000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 z wylaczeniem pkt 7.1.2 +Ap1:2016-06","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(20 – 20000) μg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 +Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","search_en":"Water, water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 z wyłączeniem pkt 7.1.2 +Ap1:2016-06"},{"_id":"6a5dc9c3f1c10c8ce825fd88","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04"},{"_id":"6a5dc9c3f1c10c8ce825fd89","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04"},{"_id":"6a5dc9c3f1c10c8ce825fd8a","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","search_en":"Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004"},{"_id":"6a5dc9c3f1c10c8ce825fd8b","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 36°C","methodology_en":"Total viable count at 36°C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"36°C 微生物总数","search_zh":"水、生活饮用水 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","search_en":"Water, water intended for human consumption Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004"},{"_id":"6a5dc9c3f1c10c8ce825fd8c","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22°C","methodology_en":"Total viable count at 22°C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"22°C 微生物总数","search_zh":"水、生活饮用水 22°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","search_en":"Water, water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004"},{"_id":"6a5dc9c3f1c10c8ce825fd8d","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda, woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"化学与物理检测用样品采集","search_zh":"水、生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"水、生活饮用水","search_en":"Water, water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10"},{"_id":"6a5dc9c3f1c10c8ce825fd8e","lab_id":"69ad52a3de79e566650fb4bc","country":"PL","accr_number":"AB 941","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"水、生活饮用水","search_en":"Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6"}],"has_pdf":true}