🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI W SUWAŁKACH PL
Water & wastewaterEnvironment
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI W SUWAŁKACH is a laboratory accredited by PCA under number AB 938 (Suwałki, Poland). Its accreditation scope covers 29 test methods in the following areas: Water & wastewater, Environment. Test objects include: Wastewater, water, Wastewater, Sewage sludge, Waste O): code 19 08 05, Water. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 938
- Methods in scope: 29
- Types of test objects: 6
- Techniques used: 7
- City: Suwałki, Poland
- Accreditation number
- AB 938
- Accreditation body
- PCA
- Address
- SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ, ul. Gen. W. Sikorskiego 14, 16-400 Suwałki, LABORATORIUM, ul. Sejneńska 86
- City
- Suwałki, Poland
What this laboratory tests (6)
- Wastewater, water — 15 methods
- Wastewater — 6 methods
- Sewage sludge, Waste O): code 19 08 05 — 4 methods
- Water — 2 methods
- Wastewater, rainwater, snowmelt water — 1 method
- Water, wastewater, rainwater, snowmelt water — 1 method
Analytical techniques used (7)
- Spectrophotometric method — 8 methods
- Gravimetric method — 5 methods
- Titrimetric method — 4 methods
- Electrochemical method — 2 methods
- Optical method — 2 methods
- Potentiometric method — 2 methods
- Manual method; Automatic method — 1 method
Laboratory locations
- Laboratorium — ul. Sejneńska 86, 16-400 Suwałki
Accreditation scope — test methods (29)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory | |||||
| 1 | Wastewater, rainwater, snowmelt water | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 2 | Wastewater | Temperature of wastewater / collected wastewater sample Range (0,5 – 50,0) °C |
PN-77/C-04584 | ||
| 3 | Wastewater | Chemical oxygen demand − COD-Cr Range (30 – 10000) mg/l O2 |
Titrimetric method | PN-ISO 6060:2006 | |
| 4 | Wastewater | Ammonium nitrogen concentration Range (0,50 – 200) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 5 | Wastewater | Orthophosphate concentration range (0,100 – 200) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4 | |
| 6 | Wastewater | Concentration of substances extractable with petroleum ether Range (10 – 1000) mg/l |
Gravimetric method | PB-24 wyd. 2 z dnia 06.03.2017 r. | |
| 7 | Wastewater | Formaldehyde concentration Range (0,050 – 20,0) mg/l |
Spectrophotometric method | „Fizyczno-chemiczne badanie wody i ścieków” W. Hermanowicz i inni, wydanie 2, Warszawa 1999, punkt 3.4.25.2 | |
| 8 | Water | Sampling for chemical and physical testing | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5. i 7.6. | PN-ISO 5667-5:2017-10 | ||
| 9 | Water | Temperature of water / of the collected water sample Range (0,5 – 50,0) °C |
PN-77/C-04584 | ||
| 10 | Wastewater, water | Chloride concentration Range (5,0 – 2000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 11 | Wastewater, water | Sulfate concentration Range (10 – 5000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 12 | Wastewater, water | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 13 | Wastewater, water | Chemical oxygen demand − COD-Cr Range (6,0 – 2000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 14 | Wastewater, water | Ammonium nitrogen concentration Range (0,050 – 15,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 15 | Wastewater, water | Nitrate nitrogen concentration Range (0,050 – 100) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 16 | Wastewater, water | Nitrite nitrogen concentration Range (0,002 – 6,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 17 | Wastewater, water | Total nitrogen concentration (calculated) | PN-73/C-04576.14 | ||
| 18 | Wastewater, water | Total phosphorus concentration Range (0,040 – 100) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8 | |
| 19 | Wastewater, water | Biochemical oxygen demand − BOD5 Range (1 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 20 | Wastewater, water | Biochemical oxygen demand − BOD5 Range (0,50 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 21 | Wastewater, water | Biochemical oxygen demand − BOD5 Range (1 – 6000) mg/l O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 22 | Wastewater, water | Biochemical oxygen demand − BOD5 Range (0,50 – 6,0) mg/l O2 |
Optical method | PN-EN 1899-2:2002 | IB-03 wyd. 1 z dn. 9.02.2026 r. | |
| 23 | Wastewater, water | Kjeldahl nitrogen concentration Range (0,50 – 500) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 24 | Wastewater, water | Phenol index Range (0,004 – 20,0) mg/l |
Spectrophotometric method | PN-ISO 6439:1994. Metoda B | |
| 25 | Water, wastewater, rainwater, snowmelt water | Total suspended solids (TSS) Range (2,0 – 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 26 | Sewage sludge, Waste O): code 19 08 05 | Sampling for chemical and physical testing Regulated area: O) kod odpadu podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3., 6.3.7. | ||
| 27 | Sewage sludge, Waste O): code 19 08 05 | pH - in H20 Range 4,0 – 12,0 Regulated area: O) kod odpadu podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 28 | Sewage sludge, Waste O): code 19 08 05 | Dry matter content Range (0,6 – 95,0) % Regulated area: O) kod odpadu podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-EN 15934:2013-02 | |
| 29 | Sewage sludge, Waste O): code 19 08 05 | Straty przy prażeniu suchej masy (LOl) / Pozostałość po prażeniu Range (10,0 – 90,0) % Regulated area: O) kod odpadu podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-EN 15935:2022-01 z wyłączeniem pkt 7.4., 8.2. | |
Reference standards (28)
IB-03 wyd. 1 z dn. 9.02.2026 r.
PB-24 wyd. 2 z dnia 06.03.2017 r.
PN-73/C-04576.14
PN-77/C-04584
PN-82/C-04576.08
PN-EN 15934:2013-02
PN-EN 15935:2022-01 z wyłączeniem pkt 7.4., 8.2.
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3., 6.3.7.
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5. i 7.6.
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6060:2006
PN-ISO 6439:1994. Metoda B
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
„Fizyczno-chemiczne badanie wody i ścieków” W. Hermanowicz i inni, wydanie 2, Warszawa 1999, punkt 3.4.25.2