🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI W SUWAŁKACH PL

PCA AB 938 • Suwałki, Poland • 29 methods

Water & wastewaterEnvironment

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI W SUWAŁKACH is a laboratory accredited by PCA under number AB 938 (Suwałki, Poland). Its accreditation scope covers 29 test methods in the following areas: Water & wastewater, Environment. Test objects include: Wastewater, water, Wastewater, Sewage sludge, Waste O): code 19 08 05, Water. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 938
  • Methods in scope: 29
  • Types of test objects: 6
  • Techniques used: 7
  • City: Suwałki, Poland
Accreditation number
AB 938
Accreditation body
PCA
Address
SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ, ul. Gen. W. Sikorskiego 14, 16-400 Suwałki, LABORATORIUM, ul. Sejneńska 86
City
Suwałki, Poland

What this laboratory tests (6)

Analytical techniques used (7)

Laboratory locations

Accreditation scope — test methods (29)

No. Test object Methodology / Parameters Technique Reference document
Laboratory
1 Wastewater, rainwater, snowmelt water Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
2 Wastewater Temperature of wastewater / collected wastewater sample
Range (0,5 – 50,0) °C
PN-77/C-04584
3 Wastewater Chemical oxygen demand − COD-Cr
Range (30 – 10000) mg/l O2
Titrimetric method PN-ISO 6060:2006
4 Wastewater Ammonium nitrogen concentration
Range (0,50 – 200) mg/l
Titrimetric method PN-ISO 5664:2002
5 Wastewater Orthophosphate concentration
range (0,100 – 200) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4
6 Wastewater Concentration of substances extractable with petroleum ether
Range (10 – 1000) mg/l
Gravimetric method PB-24 wyd. 2 z dnia 06.03.2017 r.
7 Wastewater Formaldehyde concentration
Range (0,050 – 20,0) mg/l
Spectrophotometric method „Fizyczno-chemiczne badanie wody i ścieków” W. Hermanowicz i inni, wydanie 2, Warszawa 1999, punkt 3.4.25.2
8 Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5. i 7.6. | PN-ISO 5667-5:2017-10
9 Water Temperature of water / of the collected water sample
Range (0,5 – 50,0) °C
PN-77/C-04584
10 Wastewater, water Chloride concentration
Range (5,0 – 2000) mg/l
Titrimetric method PN-ISO 9297:1994
11 Wastewater, water Sulfate concentration
Range (10 – 5000) mg/l
Gravimetric method PN-ISO 9280:2002
12 Wastewater, water pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
13 Wastewater, water Chemical oxygen demand − COD-Cr
Range (6,0 – 2000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
14 Wastewater, water Ammonium nitrogen concentration
Range (0,050 – 15,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
15 Wastewater, water Nitrate nitrogen concentration
Range (0,050 – 100) mg/l
Spectrophotometric method PN-82/C-04576.08
16 Wastewater, water Nitrite nitrogen concentration
Range (0,002 – 6,0) mg/l
Spectrophotometric method PN-EN 26777:1999
17 Wastewater, water Total nitrogen concentration (calculated) PN-73/C-04576.14
18 Wastewater, water Total phosphorus concentration
Range (0,040 – 100) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8
19 Wastewater, water Biochemical oxygen demand − BOD5
Range (1 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
20 Wastewater, water Biochemical oxygen demand − BOD5
Range (0,50 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
21 Wastewater, water Biochemical oxygen demand − BOD5
Range (1 – 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
22 Wastewater, water Biochemical oxygen demand − BOD5
Range (0,50 – 6,0) mg/l O2
Optical method PN-EN 1899-2:2002 | IB-03 wyd. 1 z dn. 9.02.2026 r.
23 Wastewater, water Kjeldahl nitrogen concentration
Range (0,50 – 500) mg/l
Titrimetric method PN-EN 25663:2001
24 Wastewater, water Phenol index
Range (0,004 – 20,0) mg/l
Spectrophotometric method PN-ISO 6439:1994. Metoda B
25 Water, wastewater, rainwater, snowmelt water Total suspended solids (TSS)
Range (2,0 – 5000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
26 Sewage sludge, Waste O): code 19 08 05 Sampling for chemical and physical testing
Regulated area: O) kod odpadu podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3., 6.3.7.
27 Sewage sludge, Waste O): code 19 08 05 pH - in H20
Range 4,0 – 12,0
Regulated area: O) kod odpadu podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Potentiometric method PN-EN ISO 10390:2022-09
28 Sewage sludge, Waste O): code 19 08 05 Dry matter content
Range (0,6 – 95,0) %
Regulated area: O) kod odpadu podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Gravimetric method PN-EN 15934:2013-02
29 Sewage sludge, Waste O): code 19 08 05 Straty przy prażeniu suchej masy (LOl) / Pozostałość po prażeniu
Range (10,0 – 90,0) %
Regulated area: O) kod odpadu podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Gravimetric method PN-EN 15935:2022-01 z wyłączeniem pkt 7.4., 8.2.

Reference standards (28)

IB-03 wyd. 1 z dn. 9.02.2026 r.
PB-24 wyd. 2 z dnia 06.03.2017 r.
PN-73/C-04576.14
PN-77/C-04584
PN-82/C-04576.08
PN-EN 15934:2013-02
PN-EN 15935:2022-01 z wyłączeniem pkt 7.4., 8.2.
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3., 6.3.7.
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5. i 7.6.
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6060:2006
PN-ISO 6439:1994. Metoda B
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
„Fizyczno-chemiczne badanie wody i ścieków” W. Hermanowicz i inni, wydanie 2, Warszawa 1999, punkt 3.4.25.2