{"lab":{"_id":"69ad52a3de79e566650fb4b6","accr_number":"AB 938","country":"PL","accr_body":"PCA","address":"SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ, ul. Gen. W. Sikorskiego 14, 16-400 Suwałki, LABORATORIUM, ul. Sejneńska 86","categories":["water","environment"],"city":"Suwałki","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI W SUWAŁKACH","parse_status":"parsed","parse_version":3,"pdf_files":["AB_938.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji w suwałkach spółka z ograniczoną odpowiedzialnością, ul. gen. w. sikorskiego 14, 16-400 suwałki, laboratorium, ul. sejneńska 86 water other","status":"active","updated_at":"2026-03-08T14:51:50.098Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:37:47.871Z","location":{"type":"Point","coordinates":[22.9307,54.1118]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20938,podmiot.html","fields_of_testing":[{"codes":"C/28/P, C/29/P, C/30/P, C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów, odpadów","en":"Chemical tests and sampling of water, drinking water, sewage, sediments, waste"},{"codes":"N/28/P, N/29/P, N/30/P, N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów, odpadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, sediments, waste"}],"issue":{"no":"20","date":"11.06.2026"},"parse_date":"2026-08-18T01:37:47.871Z","parse_source":"agent-claude-code","map_coord":[54.099064,22.927936],"map_geo":"nominatim-city","lab_locations":[{"name":"Laboratorium","address":"ul. Sejneńska 86, 16-400 Suwałki","city":"Suwałki","postal":"16-400"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/aeb4b45095660ad498ce6e41dbef1afb/AB%20938.pdf","has_en":true,"category_counts":{"water":29,"environment":4},"category_scores":{"water":25.48,"environment":0.48},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":"ul. Sejneńska 86, 16-400 Suwałki","city":"Suwałki","postal":"16-400"}]},"methods":[{"_id":"6a83b76baf14b9c0e7b20f5c","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda opadowa, woda roztopowa","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda opadowa, woda roztopowa Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki, woda opadowa, woda roztopowa Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater, rainwater, snowmelt water Sampling for chemical and physical testing Manual method; Automatic method Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater, rainwater, snowmelt water","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 手动法；自动法 实验室 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法"},{"_id":"6a83b76baf14b9c0e7b20f5d","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura ścieków / pobranej próbki ścieków","parameters":[{"name":"Zakres","range":"(0,5 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura ścieków / pobranej próbki ścieków\nZakres (0,5 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura ścieków / pobranej próbki ścieków\nZakres (0,5 – 50,0) °C PN-77/C-04584 Scieki Temperatura sciekow / pobranej probki sciekow\nZakres (0,5 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature of wastewater / collected wastewater sample","parameters_en":[{"name":"Range","range":"(0,5 – 50,0) °C"}],"search_en":"Wastewater Temperature of wastewater / collected wastewater sample Laboratory Range PN-77/C-04584","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 50,0) °C"}],"search_zh":"污水 废水/所采废水样品的温度 实验室 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"废水/所采废水样品的温度"},{"_id":"6a83b76baf14b9c0e7b20f5e","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","parameters":[{"name":"Zakres","range":"(30 – 10000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (30 – 10000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (30 – 10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (30 – 10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand − COD-Cr","parameters_en":[{"name":"Range","range":"(30 – 10000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand − COD-Cr Titrimetric method Laboratory Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(30 – 10000) mg/l O2"}],"search_zh":"污水 化学需氧量 － COD-Cr 滴定法 实验室 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a83b76baf14b9c0e7b20f5f","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,50 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,50 – 200) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,50 – 200) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (0,50 – 200) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 200) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Laboratory Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 200) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 实验室 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a83b76baf14b9c0e7b20f60","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"zakres","range":"(0,100 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nzakres (0,100 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie ortofosforanów\nzakres (0,100 – 200) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4 Scieki Stezenie ortofosforanow\nzakres (0,100 – 200) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"range","range":"(0,100 – 200) mg/l"}],"search_en":"Wastewater Orthophosphate concentration Spectrophotometric method Laboratory range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","search_zh":"污水 正磷酸盐浓度 分光光度法 实验室 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"正磷酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,100 – 200) mg/l"}]},{"_id":"6a83b76baf14b9c0e7b20f61","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PB-24 wyd. 2 z dnia 06.03.2017 r.","norm_bases":["PB-24 wyd. 2 z dnia 06.03.2017 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa PB-24 wyd. 2 z dnia 06.03.2017 r. Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa PB-24 wyd. 2 z dnia 06.03.2017 r.","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Laboratory Range PB-24 wyd. 2 z dnia 06.03.2017 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 实验室 范围 PB-24 wyd. 2 z dnia 06.03.2017 r.","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a83b76baf14b9c0e7b20f62","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie formaldehydu","parameters":[{"name":"Zakres","range":"(0,050 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie formaldehydu\nZakres (0,050 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"„Fizyczno-chemiczne badanie wody i ścieków” W. Hermanowicz i inni, wydanie 2, Warszawa 1999, punkt 3.4.25.2","norm_bases":["„Fizyczno-chemiczne badanie wody i ścieków” W. Hermanowicz i inni, wydanie 2, Warszawa 1999, punkt 3.4.25.2"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie formaldehydu\nZakres (0,050 – 20,0) mg/l\nMetoda spektrofotometryczna „Fizyczno-chemiczne badanie wody i ścieków” W. Hermanowicz i inni, wydanie 2, Warszawa 1999, punkt 3.4.25.2 Scieki Stezenie formaldehydu\nZakres (0,050 – 20,0) mg/l\nMetoda spektrofotometryczna „Fizyczno-chemiczne badanie wody i sciekow” W. Hermanowicz i inni, wydanie 2, Warszawa 1999, punkt 3.4.25.2","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Formaldehyde concentration","parameters_en":[{"name":"Range","range":"(0,050 – 20,0) mg/l"}],"search_en":"Wastewater Formaldehyde concentration Spectrophotometric method Laboratory Range „Fizyczno-chemiczne badanie wody i ścieków” W. Hermanowicz i inni, wydanie 2, Warszawa 1999, punkt 3.4.25.2","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,050 – 20,0) mg/l"}],"search_zh":"污水 甲醛浓度 分光光度法 实验室 范围 „Fizyczno-chemiczne badanie wody i ścieków” W. Hermanowicz i inni, wydanie 2, Warszawa 1999, punkt 3.4.25.2","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"甲醛浓度"},{"_id":"6a83b76baf14b9c0e7b20f63","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5. i 7.6. | PN-ISO 5667-5:2017-10","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5. i 7.6.","PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5. i 7.6. | PN-ISO 5667-5:2017-10 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt 7.5. i 7.6. | PN-ISO 5667-5:2017-10","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing Laboratory PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5. i 7.6. | PN-ISO 5667-5:2017-10","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 实验室 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5. i 7.6. | PN-ISO 5667-5:2017-10","test_object_zh":"水"},{"_id":"6a83b76baf14b9c0e7b20f64","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura wody / pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,5 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura wody / pobranej próbki wody\nZakres (0,5 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura wody / pobranej próbki wody\nZakres (0,5 – 50,0) °C PN-77/C-04584 Woda Temperatura wody / pobranej probki wody\nZakres (0,5 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature of water / of the collected water sample","parameters_en":[{"name":"Range","range":"(0,5 – 50,0) °C"}],"search_en":"Water Temperature of water / of the collected water sample Laboratory Range PN-77/C-04584","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 50,0) °C"}],"search_zh":"水 水/所采水样的温度 实验室 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"水/所采水样的温度"},{"_id":"6a83b76baf14b9c0e7b20f65","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 2000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie chlorków\nZakres (5,0 – 2000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, woda Stezenie chlorkow\nZakres (5,0 – 2000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/l"}],"search_en":"Wastewater, water Chloride concentration Titrimetric method Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/l"}],"search_zh":"废水、水 氯化物浓度 滴定法 实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a83b76baf14b9c0e7b20f66","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki, woda Stezenie siarczanow\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 5000) mg/l"}],"search_en":"Wastewater, water Sulfate concentration Gravimetric method Laboratory Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"}],"search_zh":"废水、水 硫酸盐浓度 重量法 实验室 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a83b76baf14b9c0e7b20f67","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater, water pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"废水、水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、水"},{"_id":"6a83b76baf14b9c0e7b20f68","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","parameters":[{"name":"Zakres","range":"(6,0 – 2000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (6,0 – 2000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (6,0 – 2000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, woda Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (6,0 – 2000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand − COD-Cr","parameters_en":[{"name":"Range","range":"(6,0 – 2000) mg/l O2"}],"search_en":"Wastewater, water Chemical oxygen demand − COD-Cr Spectrophotometric method Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(6,0 – 2000) mg/l O2"}],"search_zh":"废水、水 化学需氧量 － COD-Cr 分光光度法 实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a83b76baf14b9c0e7b20f69","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu amonowego\nZakres (0,050 – 15,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki, woda Stezenie azotu amonowego\nZakres (0,050 – 15,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 15,0) mg/l"}],"search_en":"Wastewater, water Ammonium nitrogen concentration Spectrophotometric method Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 15,0) mg/l"}],"search_zh":"废水、水 氨氮浓度 分光光度法 实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a83b76baf14b9c0e7b20f6a","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,050 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu azotanowego\nZakres (0,050 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki, woda Stezenie azotu azotanowego\nZakres (0,050 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 100) mg/l"}],"search_en":"Wastewater, water Nitrate nitrogen concentration Spectrophotometric method Laboratory Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 100) mg/l"}],"search_zh":"废水、水 硝态氮浓度 分光光度法 实验室 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a83b76baf14b9c0e7b20f6b","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,002 – 6,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,002 – 6,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu azotynowego\nZakres (0,002 – 6,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki, woda Stezenie azotu azotynowego\nZakres (0,002 – 6,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,002 – 6,0) mg/l"}],"search_en":"Wastewater, water Nitrite nitrogen concentration Spectrophotometric method Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,002 – 6,0) mg/l"}],"search_zh":"废水、水 亚硝态氮浓度 分光光度法 实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a83b76baf14b9c0e7b20f6c","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576.14","norm_bases":["PN-73/C-04576.14"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576.14 Scieki, woda Stezenie azotu ogolnego (z obliczen) PN-73/C-04576.14","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater, water Total nitrogen concentration (calculated) Laboratory PN-73/C-04576.14","test_object_en":"Wastewater, water","lab_section_zh":"实验室","methodology_zh":"总氮浓度（计算值）","search_zh":"废水、水 总氮浓度（计算值） 实验室 PN-73/C-04576.14","test_object_zh":"废水、水"},{"_id":"6a83b76baf14b9c0e7b20f6d","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,040 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,040 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie fosforu ogólnego\nZakres (0,040 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8 Scieki, woda Stezenie fosforu ogolnego\nZakres (0,040 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,040 – 100) mg/l"}],"search_en":"Wastewater, water Total phosphorus concentration Spectrophotometric method Laboratory Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 100) mg/l"}],"search_zh":"废水、水 总磷浓度 分光光度法 实验室 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a83b76baf14b9c0e7b20f6e","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki, woda Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand − BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Wastewater, water Biochemical oxygen demand − BOD5 Electrochemical method Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"废水、水 五日生化需氧量（BOD5） 电化学法 实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"废水、水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a83b76baf14b9c0e7b20f6f","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki, woda Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand − BOD5","parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Wastewater, water Biochemical oxygen demand − BOD5 Electrochemical method Laboratory Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"废水、水 五日生化需氧量（BOD5） 电化学法 实验室 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"废水、水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a83b76baf14b9c0e7b20f70","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki, woda Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand − BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Wastewater, water Biochemical oxygen demand − BOD5 Optical method Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"废水、水 五日生化需氧量（BOD5） 光学法 实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"废水、水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a83b76baf14b9c0e7b20f71","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 | IB-03 wyd. 1 z dn. 9.02.2026 r.","norm_bases":["PN-EN 1899-2:2002","IB-03 wyd. 1 z dn. 9.02.2026 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 | IB-03 wyd. 1 z dn. 9.02.2026 r. Scieki, woda Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 | IB-03 wyd. 1 z dn. 9.02.2026 r.","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand − BOD5","parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Wastewater, water Biochemical oxygen demand − BOD5 Optical method Laboratory Range PN-EN 1899-2:2002 | IB-03 wyd. 1 z dn. 9.02.2026 r.","technique_en":"Optical method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"废水、水 五日生化需氧量（BOD5） 光学法 实验室 范围 PN-EN 1899-2:2002 | IB-03 wyd. 1 z dn. 9.02.2026 r.","technique_zh":"光学法","test_object_zh":"废水、水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a83b76baf14b9c0e7b20f72","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,50 – 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,50 – 500) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu Kjeldahla\nZakres (0,50 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki, woda Stezenie azotu Kjeldahla\nZakres (0,50 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 500) mg/l"}],"search_en":"Wastewater, water Kjeldahl nitrogen concentration Titrimetric method Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 500) mg/l"}],"search_zh":"废水、水 凯氏氮浓度 滴定法 实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a83b76baf14b9c0e7b20f73","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,004 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,004 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994. Metoda B","norm_bases":["PN-ISO 6439:1994. Metoda B"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Indeks fenolowy\nZakres (0,004 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994. Metoda B Scieki, woda Indeks fenolowy\nZakres (0,004 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994. Metoda B","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,004 – 20,0) mg/l"}],"search_en":"Wastewater, water Phenol index Spectrophotometric method Laboratory Range PN-ISO 6439:1994. Metoda B","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,004 – 20,0) mg/l"}],"search_zh":"废水、水 酚指数 分光光度法 实验室 范围 PN-ISO 6439:1994. Metoda B","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"酚指数"},{"_id":"6a83b76baf14b9c0e7b20f74","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Woda, ścieki, woda opadowa, woda roztopowa","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, woda opadowa, woda roztopowa Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki, woda opadowa, woda roztopowa Zawiesiny ogolne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 5000) mg/l"}],"search_en":"Water, wastewater, rainwater, snowmelt water Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater, rainwater, snowmelt water","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 5000) mg/l"}],"search_zh":"总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a83b76baf14b9c0e7b20f75","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3., 6.3.7.","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3., 6.3.7."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) kod odpadu podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05 Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3., 6.3.7. Osady sciekowe, Odpady O): kod 19 08 05 Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wylaczeniem pkt 6.3.3., 6.3.7.","categories":["water","environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Sewage sludge, Waste O): code 19 08 05 Sampling for chemical and physical testing Laboratory PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3., 6.3.7.","test_object_en":"Sewage sludge, Waste O): code 19 08 05","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 实验室 PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3., 6.3.7."},{"_id":"6a83b76baf14b9c0e7b20f76","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05","methodology":"pH - w H20","parameters":[{"name":"Zakres","range":"4,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H20\nZakres 4,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) kod odpadu podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05 pH - w H20\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe, Odpady O): kod 19 08 05 pH - w H20\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water","environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH - in H20","parameters_en":[{"name":"Range","range":"4,0 – 12,0"}],"search_en":"Sewage sludge, Waste O): code 19 08 05 pH - in H20 Potentiometric method Laboratory Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge, Waste O): code 19 08 05","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"4,0 – 12,0"}],"search_zh":"电位法 实验室 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法"},{"_id":"6a83b76baf14b9c0e7b20f77","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05","methodology":"Zawartość suchej masy","parameters":[{"name":"Zakres","range":"(0,6 – 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy\nZakres (0,6 – 95,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) kod odpadu podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05 Zawartość suchej masy\nZakres (0,6 – 95,0) %\nMetoda wagowa PN-EN 15934:2013-02 Osady sciekowe, Odpady O): kod 19 08 05 Zawartosc suchej masy\nZakres (0,6 – 95,0) %\nMetoda wagowa PN-EN 15934:2013-02","categories":["water","environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Dry matter content","parameters_en":[{"name":"Range","range":"(0,6 – 95,0) %"}],"search_en":"Sewage sludge, Waste O): code 19 08 05 Dry matter content Gravimetric method Laboratory Range PN-EN 15934:2013-02","technique_en":"Gravimetric method","test_object_en":"Sewage sludge, Waste O): code 19 08 05","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,6 – 95,0) %"}],"search_zh":"干物质含量 重量法 实验室 范围 PN-EN 15934:2013-02","technique_zh":"重量法","methodology_zh":"干物质含量"},{"_id":"6a83b76baf14b9c0e7b20f78","lab_id":"69ad52a3de79e566650fb4b6","country":"PL","accr_number":"AB 938","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05","methodology":"Straty przy prażeniu suchej masy (LOl) / Pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(10,0 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOl) / Pozostałość po prażeniu\nZakres (10,0 – 90,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01 z wyłączeniem pkt 7.4., 8.2.","norm_bases":["PN-EN 15935:2022-01 z wyłączeniem pkt 7.4., 8.2."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) kod odpadu podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05 Straty przy prażeniu suchej masy (LOl) / Pozostałość po prażeniu\nZakres (10,0 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01 z wyłączeniem pkt 7.4., 8.2. Osady sciekowe, Odpady O): kod 19 08 05 Straty przy prazeniu suchej masy (LOl) / Pozostalosc po prazeniu\nZakres (10,0 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01 z wylaczeniem pkt 7.4., 8.2.","categories":["water","environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(10,0 – 90,0) %"}],"search_en":"Sewage sludge, Waste O): code 19 08 05 Gravimetric method Laboratory Range PN-EN 15935:2022-01 z wyłączeniem pkt 7.4., 8.2.","technique_en":"Gravimetric method","test_object_en":"Sewage sludge, Waste O): code 19 08 05","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(10,0 – 90,0) %"}],"search_zh":"重量法 实验室 范围 PN-EN 15935:2022-01 z wyłączeniem pkt 7.4., 8.2.","technique_zh":"重量法"}],"has_pdf":true}