🇵🇱 OŚRODEK BADAŃ PODSTAWOWYCH PROJEKTÓW I WDROŻEŃ PL

PCA AB 934 • Święta Katarzyna, Poland • 233 methods

EnvironmentWater & wastewater

OŚRODEK BADAŃ PODSTAWOWYCH PROJEKTÓW I WDROŻEŃ is a laboratory accredited by PCA under number AB 934 (Święta Katarzyna, Poland). Its accreditation scope covers 233 test methods in the following areas: Environment, Water & wastewater. Test objects include: Środowisko pracy E, Środowisko ogólne E, Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry…, Workplace environment – air. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), High-performance liquid chromatography with spectrophotometric dete…, Ion chromatography with conductometric detection (IC-CD).

At a glance

  • Accreditation number: PCA AB 934
  • Methods in scope: 233
  • Types of test objects: 44
  • Techniques used: 21
  • City: Święta Katarzyna, Poland
Accreditation number
AB 934
Accreditation body
PCA
Address
OCHRONY ŚRODOWISKA I BIOTECHNOLOGII, „OIKOS” SP. Z O.O., LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Powstańców Śląskich 8
City
Święta Katarzyna, Poland

What this laboratory tests (44)

Analytical techniques used (21)

Laboratory sections (2)

Laboratory locations

Accreditation scope — test methods (233)

No. Test object Methodology / Parameters Technique Reference document
Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek
1 Workplace environment – air Sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
2 Workplace environment – air Pobieranie próbek do oceny narażenia zawodowego na: – metale i ich związki, w tym
inhalable fraction frakcja respirabilna – substancje organiczne, w tym inhalable fraction – inorganic substances, including inhalable fraction respirable fraction thoracic fraction
Metoda dozymetrii indywidualnej – substancje organiczne – substancje nieorganiczne; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004
3 Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
4 Workplace environment – air Pobieranie próbek do oceny narażenia zawodowego na: – azbest
włókna respirabilne – ogniotrwałe włókna ceramiczne – ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi – sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych włókna respirabilne – węglik krzemu, włóknisty respirable fibres
Personal dosimetry method PN-Z-04008-7:2002 | PN-Z-04202-02:1988
5 Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04202-02:1988
6 Workplace environment – air Stężenie pyłowych czynników szkodliwych dla zdrowia frakcja wdychalna – asfalt naftowy – ditlenek tytanu – apatyty i fosforyty – cement portlandzki – grafit naturalny – grafit syntetyczny – kaolin – krzemionka bezpostaciowa i syntetyczna – pyły drewna – pyły mąki – pyły niesklasyfikowane ze względu na toksyczność – pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki – siarczan(VI) wapnia (gips) – sadza techniczna – sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien
ceramicznych – talk – węgiel (kamienny, brunatny) – węglan magnezu wapnia (dolomit) – węglik krzemu, niewłóknisty – węglik krzemu, włóknisty Range (0,15 – 20,8) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
7 Workplace environment – air Concentration of harmful dust agents
respirable fraction – apatites and phosphorites – Portland cement – natural graphite – amorphous and synthetic silica – organic dusts of animal and plant origin excluding wood and flour dusts – talc – coal (hard, brown) Range (0,09 – 6,31) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
8 Środowisko pracy – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia – próbki powietrza pobrane na filtry Stężenie / zawartość związków chromu (VI) - w przeliczeniu na Cr(VI)
Range (0,000417 – 0,05) mg/m3 Range (0,0003 - 0,036) mg w próbce
Spectrophotometric method PN-87/Z-04126/03 | IB-140 wydanie nr 1 z dnia 25.11.2024 r.
9 Środowisko pracy – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia – próbki powietrza pobrane na filtry Concentration / content of highly refined mineral oils excluding metalworking fluids
inhalable fraction Range (0,28 – 22,2) mg/m3 Range (0,2 – 8) mg w próbce
Infrared spectrometry method (IR) PN-Z-04108-5:2006
10 Workplace environment – air – air samples collected on filters Concentration / content of hydrogen peroxide
Range (0,034 – 9,6) mg/m3 Range (0,0120 – 0,288) mg w próbce
Spectrophotometric method OSHA Method 1019
11 Workplace environment – air – air samples collected on filters Concentration / content of crystalline silica (quartz, cristobalite)
respirable fraction Range (0,0056 – 0,88) mg/m3 Range (0,005 – 0,6) mg w próbce
Fourier transform infrared spectrometry (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130
12 Workplace environment – air – air samples collected on filters and on sorbent tubes Exposure index as the sum of the products of concentrations and carcinogenicity factors of 9 carcinogenic PAHs (calculated) PN-Z-04240-5:2006 z wyłączeniem pkt. 1, 5.6, 5.7, 5.8 | IB-76 wydanie nr 4 z dnia 02.02.2026 r.
13 Workplace environment – air – air samples collected into absorbing solution Chlorine concentration / content
Range (0,033 – 6,67) mg/m3 Range (0,0005 – 0,05) mg w próbce
Spectrophotometric method PN-Z-04037-03:1975
14 Workplace environment – air – air samples collected into absorbing solution Concentration / content of chloric (VII) acid
Range (0,31 – 100) mg/m3 Range (0,0125 – 1,25) mg w próbce
Spectrophotometric method Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, str. 88 - 91
15 Środowisko pracy – powietrze – próbki powietrza pobrane do worków Concentration / content:
propane (150 – 3600) mg/m3 butane (150 – 5950) mg/m3
Gas chromatography with flame ionization detection (GC-FID) IB-101 wydanie nr 2 z dnia 14.04.2021 r.
16 Indoor spaces – air Sampling for the determination of the concentration of:
organic substances inorganic substances
PN-EN ISO 16000-1:2006 | PN-EN ISO 16000-2:2008 | IB-143 wydanie nr 1 z dnia 27.03.2025 r.
17 Pomieszczenia – powietrze – próbki powietrza pobrane na rurki z sorbentem Concentration / content
formaldehyde Range (0,0167 – 3,33) mg/m3 Range (0,0001 – 0,100) mg w próbce acetaldehyde Range (0,0167 – 3,33) mg/m3 Range (0,0001 – 0,100) mg w próbce
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) ISO 16000-3:2022 | IB-81 wydanie nr 8 z dnia 12.02.2026 r.
18 Rooms intended for human occupancy: – air – air samples collected on sorbent tubes Sampling for determination of formaldehyde concentration IB-81 wydanie nr 8 z dnia 12.02.2026 r.
19 Rooms intended for human occupancy: – air – air samples collected on sorbent tubes Formaldehyde concentration / content
Range (0,2 – 200) μg/m3 Range (0,1 – 100) μg w próbce
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) IB-81 wydanie nr 8 z dnia 12.02.2026 r.
20 Rooms intended for human occupancy: – air – air samples collected on sorbent tubes Sampling for the determination of organic compound concentration IB-109 wydanie nr 4 z dnia 15.03.2024 r.
21 Rooms intended for human occupancy: – air – air samples collected on sorbent tubes Concentration / content: Range
benzene (1,0 – 4000) μg/m3 (0,5 – 2000) μg in the sample toluene (10,0 – 4000) μg/m3 (5,0 – 2000) μg in the sample xylene (10,0 – 4000) μg/m3 (5,0 – 2000) μg in the sample ethylbenzene (10,0 – 4000) μg/m3 (5,0 – 2000) μg in the sample ethyl acetate (10,0 – 4000) μg/m3 (5,0 – 2000) μg in the sample butyl acetate (10,0 – 4000) μg/m3 (5,0 – 2000) μg in the sample cyclohexanone (4,0 – 4000) μg/m3 (2,0 – 2000) μg in the sample butan-1-ol (10,0 – 4000) μg/m3 (5,0 – 2000) μg in the sample styrene (2,0 – 4000) μg/m3 (1,0 – 2000) μg in the sample ethylene glycol (100,0 – 2300,0) μg/m3 (50,0 – 1150) μg in the sample
Gas chromatography with flame ionization detection (GC-FID) IB-109 wydanie nr 4 z dnia 15.03.2024 r.
22 Groundwater Sampling for chemical and physical testing Temperature
Range (1,0 – 60,0) oC
PN-ISO 5667-11:2017-10 | IB-34 wydanie nr 3 z dnia 02.02.2026 r.
23 Wastewater Sampling for chemical and physical testing
Temperature Range (1,0 – 60,0) oC
Manual and automatic method PN-ISO 5667-10:2021-11 | IB-122 wydanie nr 1 z dnia 26.01.2018 r. | IB-34 wydanie nr 3 z dnia 02.02.2026 r.
24 Water intended for human consumption Sampling for chemical and physical testing Temperature
Range (1,0 – 60,0) oC
PN-ISO 5667-5:2017-10 | IB-34 wydanie nr 3 z dnia 02.02.2026 r.
25 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
26 Rainwater and snowmelt water Sampling for physical and chemical testing Manual method PN-ISO 5667-10:2021-11
27 Soil Sampling for chemical and physical testing PN ISO 10381-4:2007
28 Water, wastewater Total suspended solids (TSS)
Range (5,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
29 Water, wastewater pH
Range 2,0 – 11,0
Potentiometric method PN-EN ISO 10523:2012
30 Water, wastewater Free chlorine, total chlorine concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
31 Water, wastewater Mineral oil index
Range (0,15 – 30) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
32 Water Electrical conductivity
Range (10 – 3000) μS/cm
Conductometric method PN-EN 27888:1999
33 Water intended for human consumption Free chlorine concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
34 Soil pH - in H2O, pH - in KCl
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10390:2022-09
35 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry – próbki powietrza pobrane na filtry i na rurki z sorbentem, Środowisko ogólne E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na filtry i na rurki z sorbentem, Pomieszczenia E – próbki powietrza – próbki powietrza pobrane na filtry i na rurki z sorbentem Concentration / content of organic substances
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Normy, Procedury badawcze
36 Środowisko ogólne E – próbki gazów odlotowych pobrane na filtry Concentration / content of organic substances
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Procedury badawcze
37 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem – próbki powietrza pobrane do roztworu pochłaniającego, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem Concentration / content of organic substances
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
38 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem Concentration / content of organic substances
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
39 Środowisko ogólne E – próbki gazów odlotowych pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na filtry Concentration / content of organic substances
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Procedury badawcze
40 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość substancji nieorganicznych
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
41 Środowisko ogólne E – próbki gazów odlotowych pobrane na filtry Stężenie / zawartość substancji nieorganicznych
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Procedury badawcze
42 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry i na rurki z sorbentem – próbki powietrza pobrane na rurki z sorbentem – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem Concentration / content of organic substances
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy
43 Workplace environment E – air – air samples collected on filters Concentration / content of metals and their compounds
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Microwave plasma atomic emission spectrometry (MP-AES) Procedury badawcze
44 Workplace environment E – air Stężenie: – cyny i jej związków nieorganicznych, z wyjątkiem stannanu - w przeliczeniu na Sn - frakcja wdychalna – kobaltu i jego związków nieorganicznych – w przeliczeniu na Co – tritlenku glinu - w przeliczeniu na Al
inhalable fraction, frakcja respirabilna; – wodorotlenku glinu - w przeliczeniu na
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Procedury badawcze
45 Workplace environment E – air Al
inhalable fraction, frakcja respirabilna; – glinu metalicznego, glinu proszku (niestabilizowanego) inhalable fraction, frakcja respirabilna; – kadmu i jego związków nieorganicznych - w przeliczeniu na Cd frakcja wdychalna – tlenków żelaza – w przeliczeniu na Fe, tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza respirable fraction, frakcja wdychalna – manganu i jego związków nieorganicznych - w przeliczeniu na Mn inhalable fraction frakcja respirabilna, – miedzi i jej związków nieorganicznych w przeliczeniu na Cu – tlenku cynku - w przeliczeniu na Zn frakcja wdychalna – srebra – frakcja wdychalna – ołowiu i jego związków nieorganicznych w przeliczeniu na Pb inhalable fraction frakcja respirabilna, – chromu metalicznego i jego związków (chrom (II), chrom (III), chrom (VI)) w przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Microwave plasma atomic emission spectrometry (MP-AES) Procedury badawcze
46 Workplace environment E – air Stężenie: – tlenku wapnia
inhalable fraction, frakcja respirabilna – wodorotlenku wapnia inhalable fraction, frakcja respirabilna – węglanu wapnia − frakcja wdychalna – tlenku magnezu − frakcja wdychalna – dichlorku cynku - frakcja wdychalna – cyrkonu i jego związków w przeliczeniu na Zr – tytanu i jego związków – w przeliczeniu na Ti – molibdenu i jego związków w przeliczeniu na Mo – antymonu i jego związków nieorganicznych z wyjątkiem stibanu w przeliczeniu na Sb – wolframu – frakcja wdychalna – wolframu związki nierozpuszczalne - w przeliczeniu na W – srebra związki rozpuszczalne w przeliczeniu na Ag – baru i jego związków rozpuszczalnych w przeliczeniu na Ba – związków niklu, w przeliczeniu na Ni inhalable fraction, frakcja respirabilna – niklu metalicznego – wodorku litu - frakcja wdychalna – platyny metalicznej
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Microwave plasma atomic emission spectrometry (MP-AES) Procedury badawcze
47 Workplace environment E – air – air samples collected on filters Chrom metaliczny, Związki chromu (II) – w przeliczeniu na Cr(II), Związki chromu (III) - w przeliczeniu na Cr(III) (z obliczeń)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Procedura badawcza
48 Środowisko pracy E – próbki powietrza pobrane na filtry Zawartość: – cyny i jej związków nieorganicznych, z wyjątkiem stannanu - w przeliczeniu na Sn; – tritlenku glinu - w przeliczeniu na Al, – wodorotlenku glinu - w przeliczeniu na
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Procedury badawcze
49 Środowisko pracy E – próbki powietrza pobrane na filtry Al, – glinu metalicznego, glinu proszku (niestabilizowanego) – kadmu i jego związków nieorganicznych- w przeliczeniu na Cd – tlenków żelaza – w przeliczeniu na Fe, tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza – manganu i jego związków nieorganicznych - w przeliczeniu na Mn – miedzi i jej związków nieorganicznych - w przeliczeniu na Cu, – tlenku cynku - w przeliczeniu na Zn – srebra – ołowiu i jego związków nieorganicznych
w przeliczeniu na Pb – chromu metalicznego i jego związków (chrom (II), chrom (III), chrom (VI)) w przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu – tlenku wapnia – wodorotlenku wapnia – węglanu wapnia – tlenku magnezu – dichlorku cynku – kobaltu i jego związków nieorganicznych – w przeliczeniu na Co – cyrkonu i jego związków w przeliczeniu na Zr – tytanu i jego związków – w przeliczeniu na Ti – molibdenu i jego związków w przeliczeniu na Mo – antymonu i jego związków nieorganicznych z wyjątkiem stibanu calculated as Sb
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Microwave plasma atomic emission spectrometry (MP-AES) Procedury badawcze
50 Środowisko pracy E – próbki powietrza pobrane na filtry Zawartość: – wolframu – wolframu związki nierozpuszczalne
w przeliczeniu na W – srebra związki rozpuszczalne w przeliczeniu na Ag – baru i jego związków rozpuszczalnych w przeliczeniu na Ba – związków niklu, w przeliczeniu na Ni – niklu metalicznego – wodorku litu – platyny metalicznej
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Microwave plasma atomic emission spectrometry (MP-AES) Procedury badawcze
51 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Concentration / content of hydrogen fluoride
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
52 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Concentration / content of fluorides expressed as F
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
53 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Hydrogen chloride concentration / content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
54 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Concentration/content of nitric (V) acid
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
55 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Concentration / content of hydrogen bromide
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
56 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Concentration / content of phosphoric acid
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
57 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Concentration / content of sulphuric (VI) acid – thoracic fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
58 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Concentration / content of ozone
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
59 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Concentration / content of sulphur dioxide
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
60 Środowisko pracy E Nitrogen oxide concentration / content
Stężenie / zawartość ditlenku azotu Stężenie / zawartość siarkowodoru
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze
61 Środowisko pracy E Concentration / content of formic acid
Stężenie / zawartość kwasu octowego Stężenie / zawartość kwasu propionowego
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze
62 Środowisko pracy E Concentration / content of triethylamine
Stężenie / zawartość trimetyloaminy Stężenie / zawartość dietyloaminy Stężenie/zawartość dimetyloaminy Stężenie / zawartość butyloaminy Stężenie / zawartość izopropyloaminy Stężenie / zawartość etyloaminy Stężenie / zawartość metyloaminy
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze
63 Środowisko pracy E Ammonia concentration / content
Stężenie / zawartość jodu Stężenie / zawartość cyjanowodoru w przeliczeniu na CN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją amperometryczną (IC-AD) Normy, Procedury badawcze
64 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Concentration / content of ammonium sulfamate (VI) – inhalable fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
65 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Concentration / content of ammonium chloride – vapours and inhalable fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
66 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Concentration / content of potassium bromate (V) – inhalable fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
67 Środowisko pracy E – powietrze – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem Concentration / content of chloroacetic acid
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
68 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość kwasu szczawiowego
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
69 Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość tritlenku siarki
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
70 Workplace environment E – air – air samples collected on filters Stężenie / zawartość kwasu adypinowego – frakcja wdychalna
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Normy, Procedury badawcze
71 Środowisko ogólne E Sulfuric acid content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with conductometric detection (IC-CD) Procedury badawcze
72 Workplace environment E – air – air samples collected on filters Concentration / content of organic compounds:
– 4,4’-metylenobis(fenyloizocyjanian) w przeliczeniu na grupę NCO – diizocyjanian tolueno-2,4-diylu w przeliczeniu na grupę NCO – diizocyjanian tolueno-2,6-diylu w przeliczeniu na grupę NCO – diizocyjanian heksano-1,6-diylu (sześciometylenodwuizocyjanianu) w przeliczeniu na grupę NCO – diizocyjanian 2,2`-metylenodifenylu w przeliczeniu na grupę NCO – diizocyjanian 2,4`-metylenodifenylu w przeliczeniu na grupę NCO – izocyjanian 3-izocyjanianometylo-3,5,5- trimetylocykloheksylu w przeliczeniu na grupę NCO – 4,4’-diizocyjaniandicykloheksylometanu w przeliczeniu na grupę NCO – 1,5-diizocyjanianu naftalenu w przeliczeniu na grupę NCO Diizocyjaniany – w przeliczeniu na grupę NCO (suma stężeń izocyjanianowych grup funkcyjnych związków diizocyjanianów)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Normy, Procedury badawcze
73 Środowisko pracy E Concentration / content of polycyclic aromatic hydrocarbons:
anthracene benzo(a)anthracene chrysene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene dibenzo(a,h)anthracene benzo(g,h,i) perylene indeno (1,2,3, -c, d) piren
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Normy, Procedury badawcze
74 Środowisko pracy E Stężenie / zawartość izocyjanianu cykloheksylu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Normy, Procedury badawcze
75 Środowisko pracy E – powietrze – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość kwasu trichlorooctowego
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
76 Środowisko pracy E Stężenie / zawartość czerwieni zasadowej 9
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
77 Środowisko pracy E Concentration / content:
formamide N-methylformamide
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
78 Środowisko pracy E Concentration / content of acrylamide
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, procedury badawcze
79 Środowisko pracy E Concentration / content of thiram – tetramethylthiuram disulfide
inhalable fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
80 Środowisko pracy E Stężenie / zawartość 2,2-bis(4-hydroksyfenylo)-propanu (bisfenolu-A)
inhalable fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
81 Środowisko pracy E Stężenie / zawartość fenoloftaleiny-frakcji wdychalnej
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
82 Środowisko pracy E Concentration / content of hydrazine
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
83 Środowisko pracy E Concentration / content of benzoic acid
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
84 Środowisko pracy E Concentration / content of resorcinol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
85 Środowisko pracy E Concentration / content of acrylic acid
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
86 Środowisko ogólne E Concentration/content of 2-aminoethanol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
87 Środowisko pracy E Concentration / content of 2,2’-iminodiethanol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
88 Środowisko pracy E Concentration / content:
ethylenediamine 2,2’-iminobis(ethylamine) N,N’-bis (2 aminoetylo)etylenodiamina
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
89 Środowisko pracy E Stężenie / zawartość: 2-cyjanoakrylanu etylu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
90 Środowisko pracy E Formaldehyde concentration / content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
91 Środowisko ogólne E Concentration / content of acetaldehyde
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
92 Środowisko pracy E Concentration / content of glutaraldehyde
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
93 Środowisko pracy E Concentration / content of acrylaldehyde
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
94 Środowisko pracy E Concentration / content: hydroquinone
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
95 Środowisko pracy E Stężenie / zawartość propano-1,2-diolu
pary i frakcja wdychalna
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
96 Środowisko pracy E Concentration / content of 2-phenoxyethanol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
97 Środowisko pracy E Concentration / content of diisobutyl phthalate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
98 Środowisko pracy E Concentration / content of solid paraffin
inhalable fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
99 Środowisko pracy E Concentration / content of dimethyl phthalate – inhalable fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
100 Środowisko pracy E Concentration / content of diethyl phthalate – inhalable fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
101 Środowisko pracy E Concentration / content of dibutyl phthalate – inhalable fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
102 Środowisko pracy E Stężenie / zawartość eteru tert-butylometylowego
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
103 Środowisko pracy E Concentration / content of 1,1-dichloroethane
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
104 Środowisko pracy E Concentration / content of 1,2-dichloroethane
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
105 Środowisko pracy E Concentration / content of propane-1,3-sultone
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
106 Środowisko pracy E Stężenie / zawartość eteru tert-butyloetylowego
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
107 Środowisko pracy E Concentration / content of 2-methoxyethanol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
108 Środowisko pracy E Stężenie /z awartość 1-etylo-2-pirolidonu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
109 Środowisko pracy E Concentration / content of glycerol – inhalable fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
110 Środowisko pracy E Concentration / content of 2,2'- oxydiethanol (diethylene glycol) – inhalable fraction
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
111 Środowisko pracy E Concentration / content of trimethylbenzene
mixture of isomers (1,2,3-, 1,2,4- i 1,3,5-)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
112 Środowisko pracy E Stężenie / zawartość octanu 2-metoksypropylu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
113 Środowisko pracy E Concentration / content of ethyltoluene (mixture of isomers)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
114 Środowisko pracy E Concentration / content of cumene
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
115 Środowisko pracy E Concentration / content of propan-2-ol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
116 Środowisko pracy E Concentration / content of butan-2-one
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
117 Środowisko pracy E Concentration / content of 4-methylpentan-2-one
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
118 Środowisko pracy E Concentration / content of 2-butoxyethyl acetate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
119 Środowisko pracy E Concentration / content of dichloromethane
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
120 Środowisko pracy E Concentration / content of 2-(2-butoxyethoxy)ethanol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
121 Środowisko pracy E Concentration / content of phenylmethanol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
122 Środowisko pracy E Concentration / content of ethylene glycol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
123 Środowisko pracy E Concentration / content of acetonitrile
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
124 Środowisko pracy E Concentration / content of bis(2-ethylhexyl) phthalate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
125 Środowisko pracy E Concentration / content of cyclohexanone
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
126 Środowisko pracy E Concentration / content of vinyltoluene (mixture of isomers)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
127 Środowisko pracy E Concentration / content of 1-methoxypropan-2-ol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
128 Środowisko pracy E Styrene concentration / content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
129 Środowisko pracy E Concentration / content of diethyl ether
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
130 Środowisko pracy E Concentration / content of chloroform
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
131 Środowisko pracy E Concentration / content of propyl acetate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
132 Środowisko pracy E Concentration / content of ethylbenzene
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
133 Środowisko pracy E Trichloroethene concentration/content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
134 Środowisko pracy E Tetrachloroethene concentration/content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
135 Środowisko pracy E Concentration/content of tetrahydrofuran
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
136 Środowisko pracy E Phenol concentration/content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
137 Środowisko pracy E Turpentine concentration/content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
138 Środowisko pracy E Concentration / content of 1-methyl-2-pyrrolidone
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
139 Środowisko pracy E Pentane concentration / content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
140 Środowisko ogólne E Concentration / content of hexane
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
141 Środowisko pracy E Concentration / content of heptane
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
142 Środowisko pracy E Concentration / content of cyclohexanol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
143 Środowisko pracy E Concentration / content of 2-furylmethanol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
144 Środowisko pracy E Concentration / content of 2-methoxy-1-methylethyl acetate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
145 Środowisko pracy E Concentration / content of methylcyclohexane
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
146 Środowisko pracy E Concentration / content of cyclohexane
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
147 Środowisko pracy E Concentration / content of vinyl acetate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
148 Środowisko pracy E Concentration / content of propan-1-ol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
149 Środowisko pracy E Concentration / content of chloroethene (vinyl chloride)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
150 Środowisko pracy E Concentration / content of epoxyethane
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
151 Środowisko pracy E Concentration / content of buta-1,3-diene
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
152 Środowisko pracy E Concentration / content of 1-chloro-2,3-epoxypropane
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
153 Środowisko pracy E Concentration / content of acrylonitrile
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
154 Środowisko pracy E Concentration / content of 4-hydroxy-4-methylpentan-2-one
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
155 Środowisko pracy E Concentration / content of white spirit
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
156 Środowisko pracy E Concentration / content of kerosene
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
157 Środowisko pracy E Concentration / content of extraction naphtha
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
158 Środowisko pracy E Benzene concentration / content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
159 Środowisko pracy E Concentration / content of organic compounds:
ethanol butan-1-ol 2-methylpropan-1-ol 2-ethoxyethanol 2-butoxyethanol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
160 Środowisko pracy E Stężenie / zawartość: (2-metoksymetyloetoksy)-propanolu
mieszaniny izomerów: 1 (2-metoksy-1-metyloetoksy)propan-2- ol, 1 (2-metoksy-2-metyloetoksy)propan-2- ol, 2 (2-metoksy-1-metyloetoksy)propan-1-ol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
161 Środowisko pracy E Concentration / content of organic compounds:
toluene ksylen - mieszanina izomerów: Range 1,2-; 1,3-; 1,4-
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
162 Środowisko pracy E Concentration / content of organic compounds:
n-butyl acetate 2-ethoxyethyl acetate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
163 Środowisko pracy E Concentration / content of organic compounds:
ethyl acetate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
164 Środowisko pracy E Concentration / content of organic compounds:
acetone
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
165 Środowisko pracy E Concentration / content of diphenyl ether
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
166 Środowisko pracy E Naphthalene concentration / content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
167 Środowisko pracy E Concentration / content of aniline
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
168 Środowisko pracy E Concentration / content of methanol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
169 Środowisko pracy E Concentration / content of n-octane
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
170 Środowisko pracy E Chlorobenzene concentration / content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
171 Środowisko pracy E Stężenie / zawartość N,N-dimetyloformamidu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
172 Środowisko pracy E Stężenie / zawartość dimetoksymetanu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
173 Środowisko pracy E Stężenie / zawartość izoprenu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
174 Środowisko pracy E Stężenie / zawartość cykloheksyloaminy
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
175 Środowisko pracy E Concentration / content of methyl acrylate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
176 Środowisko pracy E Concentration / content of ethyl acrylate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
177 Środowisko pracy E Concentration / content of butyl acrylate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
178 Środowisko pracy E Stężenie / zawartość akrylanu 2-etyloheksylu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
179 Środowisko pracy E Concentration / content of methyl methacrylate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
180 Środowisko pracy E Concentration / content of butyl methacrylate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
181 Środowisko pracy E Concentration / content of methyl acetate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
182 Środowisko pracy E Concentration / content of isobutyl acetate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
183 Środowisko pracy E Concentration / content of isopropyl acetate
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
184 Środowisko pracy E Concentration / content of heptan-2-one
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
185 Środowisko ogólne E Concentration / content of 2- methylpropan-2-ol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
186 Środowisko pracy E Stężenie / zawartość 3a, 4, 7, 7a-tetrahydro-4,7-metanoindenu (dicyklopentadienu)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
187 Środowisko pracy E Stężenie / zawartość octanu izopentylu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
188 Środowisko pracy E – powietrze – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość 2-(Dietyloamino)etanolu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy
189 Środowisko pracy E Concentration / content of butan-2-ol
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
190 Środowisko ogólne E – próbki gazów odlotowych pobranych na rurki z sorbentem Organic compound content:
phenol 2-furylmethanol dimethyl phthalate diethyl phthalate dibutyl phthalate bis phthalate (2-etyloheksylu) fenylometanol cykloheksyloamina
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
191 Środowisko ogólne E Content of aromatic hydrocarbons:
trimethylbenzene etylotoluen winylotoluen benzene toluene cumene xylene ethylbenzene styrene propylbenzene
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
192 Środowisko ogólne E Organic compound content:
acetone butan-2-one methyl isobutyl ketone ethyl acetate butyl acetate ethanol butanol methylpropanol ethoxyethyl acetate methoxypropyl acetate (octan 2-metoksy-1-metyloetylu) etoksyetanol butoksyetanol metoksypropanol epoksyetan dichloromethane trichloroethylene tetrachloroethylene cyclohexanol (benzyna ekstrakcyjna) węglowodory alifatyczne od C5 do C12 octan n-propylu isopropanol 2-butoxyethyl acetate n-metylopirolidon acetic acid 1-chloro-2,3-epoksypropan alkohol diacetonowy cyclohexanone ethylene glycol acrylonitrile tetrahydrofuran methanol methyl methacrylate butyl methacrylate turpentine (węglowodory alifatyczne do C12) cyclohexane methyl acetate vinyl acetate chlorobenzene dimetyloformamid
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
193 Środowisko ogólne E 2-methoxypropyl acetate (methoxypropyl acetate) content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
194 Środowisko ogólne E Hydrogen cyanide content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Ion chromatography with amperometric detection (IC-AD) Normy, Procedury badawcze
195 Środowisko ogólne E Chromium(VI) content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Spectrophotometric method Normy, Procedury badawcze
196 Środowisko ogólne E Organic compound content:
4,4’-metylenobis(fenyloizocyjanianu) toluene-2,4-diyl diisocyanate toluene-2,6-diyl diisocyanate hexane-1,6-diyl diisocyanate (hexamethylene diisocyanate) diizocyjanianu 2,2`-metylenodifenylu diizocyjanianu 2,4`-metylenodifenylu 1,5-diizocyjanianu naftalenu izocyjanianu 3-izocyjanianometylo-3,5,5 trimetylocykloheksylu 4,4’-diizocyjanianu dicykloheksylometanu izocyjanianu cykloheksylu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Procedury badawcze
197 Środowisko ogólne E Aniline content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy, Procedury badawcze
198 Środowisko ogólne E Organic compound content:
acetaldehyde glutaraldehyd formaldehyde akrylaldehyd
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Normy, Procedury badawcze
199 Środowisko ogólne E Sum of aromatic hydrocarbons (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Normy
200 Środowisko ogólne E Sum of aliphatic hydrocarbons (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Normy
201 Środowisko ogólne E Zawartość związków organicznych: octanu izopentylu
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) Normy
Zespół Pomiarów Środowiskowych i Pobierania Próbek
202 Workplace environment – air Carbon monoxide concentration
Range (2,3 – 187) mg/m3 Range (2,0 –161) ppm
Electrochemical method IB-129 wydanie nr 2 z dnia 14.02.2024 r.
203 Workplace environment – air Carbon dioxide concentration
Range (695 – 73290) mg/m3
Electrochemical method IB-129 wydanie nr 2 z dnia 14.02.2024 r.
204 Workplace environment – air Exposure index (calculated) IB-129 wydanie nr 2 z dnia 14.02.2024 r.
205 Workplace environment – cold microclimate Air temperature
Range (-30 – 10) °C Black globe temperature Range (-30 – 15) °C Air humidity Range (15 – 90) % Air velocity Range (0,15 – 5) m/s
Direct measurement method PN-EN ISO 11079:2008
206 Workplace environment – cold microclimate tWC index, IREQmin index, IREQneutral index (calculated) PN-EN ISO 11079:2008
207 Workplace environment – moderate microclimate Air temperature
Range (10 – 30) °C Black globe temperature Range (10 – 50) °C Air humidity Range (15 – 90) % Air velocity Range (0,15 – 5) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
208 Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
209 Workplace environment – hot microclimate Air temperature
Range (10 – 90) °C Natural wet bulb temperature Range (10 – 50) °C Black globe temperature Range (10 – 90) °C
Direct measurement method PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04
210 Workplace environment – hot microclimate WBGTeff index (calculated) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04
211 Workplace environment – indoor electric lighting Illuminance
Range (5 – 10000) lx
Direct measurement method IB-62 wydanie nr 3 z dnia 16.03.2026 r.
212 Workplace environment – indoor electric lighting Illuminance uniformity (calculated) IB-62 wydanie nr 3 z dnia 16.03.2026 r.
213 Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,2 – 500) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
214 Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
215 Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,03 – 120) m/s2
Direct measurement method PN-EN 14253+A1:2011
216 Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
217 Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (22,0 – 136,0) dB C-weighted peak sound pressure level Range (50,0 – 139,0) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11
218 Workplace environment – noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11
219 Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (55 - 138) dB C-weighted peak sound pressure level Range (55 - 143) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2025-11 strategia nr 3
220 Workplace environment – noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2025-11 strategia nr 3
221 Workplace environment – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz
Range (49 – 161) dB
Direct measurement method PN-Z-01339:2020-12
222 Workplace environment – ultrasonic noise Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-Z-01339:2020-12
223 Machinery and equipment – noise A-weighted equivalent sound pressure level
Range (24 – 136) dB
Direct measurement method PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09
224 Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09
225 General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level
Range (22,0 – 136,0) dB
Direct measurement method Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H
226 General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H
227 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (24 – 136) dB
Direct measurement method Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
228 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
229 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound pressure level
Range (24 – 136) dB
Direct measurement method PN-87/B-02156
230 Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated) PN-87/B-02156
231 Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms A-, C-weighted equivalent sound level A-, C-weighted maximum sound level
Range (24 – 136) dB
Direct measurement method PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12
232 Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms Reference equivalent A, C sound level for the operating cycle (calculated) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12
233 Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms Reference maximum A, C sound level for the operating cycle (calculated) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12

Reference standards (65)

IB-101 wydanie nr 2 z dnia 14.04.2021 r.
IB-109 wydanie nr 4 z dnia 15.03.2024 r.
IB-122 wydanie nr 1 z dnia 26.01.2018 r.
IB-129 wydanie nr 2 z dnia 14.02.2024 r.
IB-140 wydanie nr 1 z dnia 25.11.2024 r.
IB-143 wydanie nr 1 z dnia 27.03.2025 r.
IB-34 wydanie nr 3 z dnia 02.02.2026 r.
IB-62 wydanie nr 3 z dnia 16.03.2026 r.
IB-76 wydanie nr 4 z dnia 02.02.2026 r.
IB-81 wydanie nr 8 z dnia 12.02.2026 r.
ISO 16000-3:2022
Normy
Normy, Procedury badawcze
Normy, procedury badawcze
OSHA Method 1019
PN ISO 10381-4:2007
PN-87/B-02156
PN-87/Z-04126/03
PN-EN 14253+A1:2011
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10052:2007
PN-EN ISO 10052:2007/Ap1:2010
PN-EN ISO 10052:2021-12
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11079:2008
PN-EN ISO 16000-1:2006
PN-EN ISO 16000-2:2008
PN-EN ISO 19458:2007
PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3
PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4
PN-EN ISO 3746:2011/Ap1:2017-09
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7243:2018-01/Ap2:2020-04
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9377-2:2003
PN-EN ISO 9612:2025-11 strategia nr 3
PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10
PN-ISO 5667-5:2017-10
PN-N-01307:1994
PN-Z-01339:2020-12
PN-Z-04008-7:2002
PN-Z-04008-7:2002+Az1:2004
PN-Z-04037-03:1975
PN-Z-04108-5:2006
PN-Z-04202-02:1988
PN-Z-04240-5:2006 z wyłączeniem pkt. 1, 5.6, 5.7, 5.8
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, str. 88 - 91
Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130
Procedura badawcza
Procedury badawcze
Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H