{"lab":{"_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","address":"OCHRONY ŚRODOWISKA I BIOTECHNOLOGII, „OIKOS” SP. Z O.O., LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Powstańców Śląskich 8","categories":["environment","water","materials"],"city":"Święta Katarzyna","imported_at":"2026-03-08T10:42:43.265Z","methods_count":233,"name":"OŚRODEK BADAŃ PODSTAWOWYCH PROJEKTÓW I WDROŻEŃ","parse_status":"parsed","parse_version":3,"pdf_files":["AB_934.pdf"],"scope_summary":"","search_text":"ośrodek badań podstawowych projektów i wdrożeń ochrony środowiska i biotechnologii, „oikos” sp. z o.o., laboratorium badań środowiskowych, ul. powstańców śląskich 8 environment other automotive food petro construction electronics materials water microbiology pharma metrology","status":"active","updated_at":"2026-03-08T14:51:49.747Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:39:34.666Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20934,podmiot.html","fields_of_testing":[{"codes":"– A/13","pl":"Badania akustyczne i drgań – maszyny","en":"Acoustic and vibration tests of machinery"},{"codes":"– C/9","pl":"Badania chemiczne powietrza","en":"Chemical tests of air"},{"codes":"– C/28/P, C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków,","en":"Chemical tests and sampling of water, drinking water, sewage, waste gases"},{"codes":"– C/33/P, C/35/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze), pomieszczenia (warunki środowiskowe – powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air), facilities (environmental conditions – air)"},{"codes":"– C/36","pl":"Badania chemiczne próbek gazów odlotowych","en":"Chemical tests of samples of waste gases"},{"codes":"– G/33, G/34, G/35","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy ( czynniki szkodliwe i uciążliwe - drgania, oświetlenie, mikroklimat, hałas, hałas ultradźwiękowy), środowisko ogólne (czynniki fizyczne – hałas), pomieszczenia (warunki środowiskowe – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – vibration, lighting, microclimate, noise, ultrasonic noise), general environment (physical factors – noise), facilities (environmental conditions – noise)"},{"codes":"– N/28/P, N/29/P, N/30/P, N/31/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleby","en":"Tests of physical properties and sampling of air, water, drinking water, sewage, soil"},{"codes":"– N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"– P/29, P/31","pl":"Pobieranie próbek wody do spożycia przez ludzi, gleby","en":"Sampling of drinking water, soil"}],"issue":{"no":"32","date":"03.07.2026"},"parse_date":"2026-08-18T01:39:34.666Z","parse_source":"agent-claude-code","map_coord":[51.024633,17.114736],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAŃ ŚRODOWISKOWYCH","address":"ul. Powstańców Śląskich 8","city":null,"postal":null},{"name":"Pracownia Ogólnochemiczna","address":"ul. Powstańców Śląskich 8, 55-010 Święta Katarzyna","city":"Święta Katarzyna","postal":"55-010"},{"name":"Pracownia Chromatografii Gazowej","address":"ul. Powstańców Śląskich 8, 55-010 Święta Katarzyna","city":"Święta Katarzyna","postal":"55-010"},{"name":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","address":"ul. Powstańców Śląskich 8, 55-010 Święta Katarzyna","city":"Święta Katarzyna","postal":"55-010"},{"name":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/a683ee6f14628d095958eb5e3597b0f9/AB%20934.pdf","has_en":true,"category_counts":{"environment":222,"water":11,"materials":7,"petro":3,"construction":2,"metrology":2,"automotive":1,"microbiology":1},"category_scores":{"environment":197.93,"water":0.49,"materials":0.2,"petro":0.04,"construction":0.02,"metrology":0.02,"automotive":0,"microbiology":0},"has_zh":true},"methods":[{"_id":"6a83b7d6af14b9c0e7b20fe0","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"}]},{"_id":"6a83b7d6af14b9c0e7b20fe1","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na: – metale i ich związki, w tym","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna – substancje organiczne, w tym"},{"name":"frakcja wdychalna – substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"frakcja torakalna"}],"technique":"Metoda dozymetrii indywidualnej – substancje organiczne – substancje nieorganiczne; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej – substancje organiczne – substancje nieorganiczne","Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na: – metale i ich związki, w tym\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna – substancje organiczne, w tym\nfrakcja wdychalna – substancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej – substancje organiczne – substancje nieorganiczne; Metoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na: – metale i ich związki, w tym\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna – substancje organiczne, w tym\nfrakcja wdychalna – substancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej – substancje organiczne – substancje nieorganiczne; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na: – metale i ich zwiazki, w tym\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna – substancje organiczne, w tym\nfrakcja wdychalna – substancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej – substancje organiczne – substancje nieorganiczne; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction"},{"name":"frakcja respirabilna – substancje organiczne, w tym"},{"name":"inhalable fraction – inorganic substances, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"thoracic fraction"}],"search_en":"Workplace environment – air inhalable fraction inhalable fraction – inorganic substances, including inhalable fraction respirable fraction thoracic fraction PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"可吸入组分"},{"name":"frakcja respirabilna – substancje organiczne, w tym"},{"name":"frakcja wdychalna – substancje nieorganiczne, w tym"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"胸腔组分"}],"search_zh":"工作场所环境 — 空气 可吸入组分 可吸入组分 呼吸性组分 胸腔组分 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b7d6af14b9c0e7b20fe2","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b7d6af14b9c0e7b20fe3","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na: – azbest","parameters":[{"name":"włókna respirabilne – ogniotrwałe włókna ceramiczne – ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi – sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"włókna respirabilne – węglik krzemu, włóknisty"},{"name":"włókna respirabilne"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na: – azbest\nZakres:\nwłókna respirabilne – ogniotrwałe włókna ceramiczne – ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi – sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nwłókna respirabilne – węglik krzemu, włóknisty\nwłókna respirabilne\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04202-02:1988","norm_bases":["PN-Z-04008-7:2002","PN-Z-04202-02:1988"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na: – azbest\nZakres:\nwłókna respirabilne – ogniotrwałe włókna ceramiczne – ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi – sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nwłókna respirabilne – węglik krzemu, włóknisty\nwłókna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04202-02:1988 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na: – azbest\nZakres:\nwlokna respirabilne – ogniotrwale wlokna ceramiczne – ogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi – sztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych\nwlokna respirabilne – weglik krzemu, wloknisty\nwlokna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04202-02:1988","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"włókna respirabilne – ogniotrwałe włókna ceramiczne – ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi – sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"włókna respirabilne – węglik krzemu, włóknisty"},{"name":"respirable fibres"}],"search_en":"Workplace environment – air Personal dosimetry method respirable fibres PN-Z-04008-7:2002 | PN-Z-04202-02:1988","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 个体剂量测定法 呼吸性纤维 PN-Z-04008-7:2002 | PN-Z-04202-02:1988","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"włókna respirabilne – ogniotrwałe włókna ceramiczne – ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi – sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"włókna respirabilne – węglik krzemu, włóknisty"},{"name":"呼吸性纤维"}]},{"_id":"6a83b7d6af14b9c0e7b20fe4","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04202-02:1988","norm_bases":["PN-Z-04008-7:2002","PN-Z-04202-02:1988"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04202-02:1988 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04202-02:1988","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04202-02:1988","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002 | PN-Z-04202-02:1988","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b7d6af14b9c0e7b20fe5","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia frakcja wdychalna – asfalt naftowy – ditlenek tytanu – apatyty i fosforyty – cement portlandzki – grafit naturalny – grafit syntetyczny – kaolin – krzemionka bezpostaciowa i syntetyczna – pyły drewna – pyły mąki – pyły niesklasyfikowane ze względu na toksyczność – pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki – siarczan(VI) wapnia (gips) – sadza techniczna – sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien","parameters":[{"name":"ceramicznych – talk – węgiel (kamienny, brunatny) – węglan magnezu wapnia (dolomit) – węglik krzemu, niewłóknisty – węglik krzemu, włóknisty"},{"name":"Zakres","range":"(0,15 – 20,8) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia frakcja wdychalna – asfalt naftowy – ditlenek tytanu – apatyty i fosforyty – cement portlandzki – grafit naturalny – grafit syntetyczny – kaolin – krzemionka bezpostaciowa i syntetyczna – pyły drewna – pyły mąki – pyły niesklasyfikowane ze względu na toksyczność – pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki – siarczan(VI) wapnia (gips) – sadza techniczna – sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien\nZakres:\nceramicznych – talk – węgiel (kamienny, brunatny) – węglan magnezu wapnia (dolomit) – węglik krzemu, niewłóknisty – węglik krzemu, włóknisty\nZakres (0,15 – 20,8) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia frakcja wdychalna – asfalt naftowy – ditlenek tytanu – apatyty i fosforyty – cement portlandzki – grafit naturalny – grafit syntetyczny – kaolin – krzemionka bezpostaciowa i syntetyczna – pyły drewna – pyły mąki – pyły niesklasyfikowane ze względu na toksyczność – pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki – siarczan(VI) wapnia (gips) – sadza techniczna – sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien\nZakres:\nceramicznych – talk – węgiel (kamienny, brunatny) – węglan magnezu wapnia (dolomit) – węglik krzemu, niewłóknisty – węglik krzemu, włóknisty\nZakres (0,15 – 20,8) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia frakcja wdychalna – asfalt naftowy – ditlenek tytanu – apatyty i fosforyty – cement portlandzki – grafit naturalny – grafit syntetyczny – kaolin – krzemionka bezpostaciowa i syntetyczna – pyly drewna – pyly maki – pyly niesklasyfikowane ze wzgledu na toksycznosc – pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki – siarczan(VI) wapnia (gips) – sadza techniczna – sztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien\nZakres:\nceramicznych – talk – wegiel (kamienny, brunatny) – weglan magnezu wapnia (dolomit) – weglik krzemu, niewloknisty – weglik krzemu, wloknisty\nZakres (0,15 – 20,8) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"ceramicznych – talk – węgiel (kamienny, brunatny) – węglan magnezu wapnia (dolomit) – węglik krzemu, niewłóknisty – węglik krzemu, włóknisty"},{"name":"Range","range":"(0,15 – 20,8) mg/m3"}],"search_en":"Workplace environment – air Gravimetric method Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"ceramicznych – talk – węgiel (kamienny, brunatny) – węglan magnezu wapnia (dolomit) – węglik krzemu, niewłóknisty – węglik krzemu, włóknisty"},{"name":"范围","range":"(0,15 – 20,8) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b7d6af14b9c0e7b20fe6","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia","parameters":[{"name":"frakcja respirabilna – apatyty i fosforyty – cement portlandzki – grafit naturalny – krzemionka bezpostaciowa i syntetyczna – pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki – talk – węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,09 – 6,31) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia\nZakres:\nfrakcja respirabilna – apatyty i fosforyty – cement portlandzki – grafit naturalny – krzemionka bezpostaciowa i syntetyczna – pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki – talk – węgiel (kamienny, brunatny)\nZakres (0,09 – 6,31) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia\nZakres:\nfrakcja respirabilna – apatyty i fosforyty – cement portlandzki – grafit naturalny – krzemionka bezpostaciowa i syntetyczna – pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki – talk – węgiel (kamienny, brunatny)\nZakres (0,09 – 6,31) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia\nZakres:\nfrakcja respirabilna – apatyty i fosforyty – cement portlandzki – grafit naturalny – krzemionka bezpostaciowa i syntetyczna – pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki – talk – wegiel (kamienny, brunatny)\nZakres (0,09 – 6,31) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents","parameters_en":[{"name":"respirable fraction – apatites and phosphorites – Portland cement – natural graphite – amorphous and synthetic silica – organic dusts of animal and plant origin excluding wood and flour dusts – talc – coal (hard, brown)"},{"name":"Range","range":"(0,09 – 6,31) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents Gravimetric method respirable fraction – apatites and phosphorites – Portland cement – natural graphite – amorphous and synthetic silica – organic dusts of animal and plant origin excluding wood and flour dusts – talc – coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"frakcja respirabilna – apatyty i fosforyty – cement portlandzki – grafit naturalny – krzemionka bezpostaciowa i syntetyczna – pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki – talk – węgiel (kamienny, brunatny)"},{"name":"范围","range":"(0,09 – 6,31) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害健康的粉尘因子浓度 重量法 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害健康的粉尘因子浓度"},{"_id":"6a83b7d6af14b9c0e7b20fe7","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość związków chromu (VI) - w przeliczeniu na Cr(VI)","parameters":[{"name":"Zakres","range":"(0,000417 – 0,05) mg/m3"},{"name":"Zakres","range":"(0,0003 - 0,036) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość związków chromu (VI) - w przeliczeniu na Cr(VI)\nZakres:\nZakres (0,000417 – 0,05) mg/m3\nZakres (0,0003 - 0,036) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-87/Z-04126/03 | IB-140 wydanie nr 1 z dnia 25.11.2024 r.","norm_bases":["PN-87/Z-04126/03","IB-140 wydanie nr 1 z dnia 25.11.2024 r."],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia – próbki powietrza pobrane na filtry Stężenie / zawartość związków chromu (VI) - w przeliczeniu na Cr(VI)\nZakres:\nZakres (0,000417 – 0,05) mg/m3\nZakres (0,0003 - 0,036) mg w próbce\nMetoda spektrofotometryczna PN-87/Z-04126/03 | IB-140 wydanie nr 1 z dnia 25.11.2024 r. Srodowisko pracy – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia – probki powietrza pobrane na filtry Stezenie / zawartosc zwiazkow chromu (VI) - w przeliczeniu na Cr(VI)\nZakres:\nZakres (0,000417 – 0,05) mg/m3\nZakres (0,0003 - 0,036) mg w probce\nMetoda spektrofotometryczna PN-87/Z-04126/03 | IB-140 wydanie nr 1 z dnia 25.11.2024 r.","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,000417 – 0,05) mg/m3"},{"name":"Range","range":"(0,0003 - 0,036) mg w próbce"}],"search_en":"Spectrophotometric method Range Range PN-87/Z-04126/03 | IB-140 wydanie nr 1 z dnia 25.11.2024 r.","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,000417 – 0,05) mg/m3"},{"name":"范围","range":"(0,0003 - 0,036) mg w próbce"}],"search_zh":"分光光度法 范围 范围 PN-87/Z-04126/03 | IB-140 wydanie nr 1 z dnia 25.11.2024 r.","technique_zh":"分光光度法"},{"_id":"6a83b7d6af14b9c0e7b20fe8","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,28 – 22,2) mg/m3"},{"name":"Zakres","range":"(0,2 – 8) mg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Stężenie / zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych\nZakres:\nfrakcja wdychalna\nZakres (0,28 – 22,2) mg/m3\nZakres (0,2 – 8) mg w próbce\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-Z-04108-5:2006","norm_bases":["PN-Z-04108-5:2006"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia – próbki powietrza pobrane na filtry Stężenie / zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych\nZakres:\nfrakcja wdychalna\nZakres (0,28 – 22,2) mg/m3\nZakres (0,2 – 8) mg w próbce\nMetoda spektrometrii w podczerwieni (IR) PN-Z-04108-5:2006 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia – probki powietrza pobrane na filtry Stezenie / zawartosc olejow mineralnych wysokorafinowanych z wylaczeniem cieczy obrobkowych\nZakres:\nfrakcja wdychalna\nZakres (0,28 – 22,2) mg/m3\nZakres (0,2 – 8) mg w probce\nMetoda spektrometrii w podczerwieni (IR) PN-Z-04108-5:2006","categories":["environment","petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of highly refined mineral oils excluding metalworking fluids","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,28 – 22,2) mg/m3"},{"name":"Range","range":"(0,2 – 8) mg w próbce"}],"search_en":"Concentration / content of highly refined mineral oils excluding metalworking fluids Infrared spectrometry method (IR) inhalable fraction Range Range PN-Z-04108-5:2006","technique_en":"Infrared spectrometry method (IR)","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,28 – 22,2) mg/m3"},{"name":"范围","range":"(0,2 – 8) mg w próbce"}],"search_zh":"红外光谱法（IR） 可吸入组分 范围 范围 PN-Z-04108-5:2006","technique_zh":"红外光谱法（IR）"},{"_id":"6a83b7d6af14b9c0e7b20fe9","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość nadtlenku wodoru","parameters":[{"name":"Zakres","range":"(0,034 – 9,6) mg/m3"},{"name":"Zakres","range":"(0,0120 – 0,288) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość nadtlenku wodoru\nZakres:\nZakres (0,034 – 9,6) mg/m3\nZakres (0,0120 – 0,288) mg w próbce\nMetoda spektrofotometryczna","reference":"OSHA Method 1019","norm_bases":["OSHA Method 1019"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość nadtlenku wodoru\nZakres:\nZakres (0,034 – 9,6) mg/m3\nZakres (0,0120 – 0,288) mg w próbce\nMetoda spektrofotometryczna OSHA Method 1019 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc nadtlenku wodoru\nZakres:\nZakres (0,034 – 9,6) mg/m3\nZakres (0,0120 – 0,288) mg w probce\nMetoda spektrofotometryczna OSHA Method 1019","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of hydrogen peroxide","parameters_en":[{"name":"Range","range":"(0,034 – 9,6) mg/m3"},{"name":"Range","range":"(0,0120 – 0,288) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Concentration / content of hydrogen peroxide Spectrophotometric method Range Range OSHA Method 1019","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,034 – 9,6) mg/m3"},{"name":"范围","range":"(0,0120 – 0,288) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 过氧化氢的浓度/含量 分光光度法 范围 范围 OSHA Method 1019","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","methodology_zh":"过氧化氢的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b20fea","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość krystalicznej krzemionki (kwarc, krystobalit)","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0056 – 0,88) mg/m3"},{"name":"Zakres","range":"(0,005 – 0,6) mg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie / zawartość krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,0056 – 0,88) mg/m3\nZakres (0,005 – 0,6) mg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,0056 – 0,88) mg/m3\nZakres (0,005 – 0,6) mg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,0056 – 0,88) mg/m3\nZakres (0,005 – 0,6) mg w probce\nMetoda spektrometrii w podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4(74) s. 117-130","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of crystalline silica (quartz, cristobalite)","parameters_en":[{"name":"respirable fraction"},{"name":"Range","range":"(0,0056 – 0,88) mg/m3"},{"name":"Range","range":"(0,005 – 0,6) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Concentration / content of crystalline silica (quartz, cristobalite) Fourier transform infrared spectrometry (FT-IR) respirable fraction Range Range Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(0,0056 – 0,88) mg/m3"},{"name":"范围","range":"(0,005 – 0,6) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 结晶二氧化硅（石英、方石英）的浓度/含量 傅里叶变换红外光谱法（FT-IR） 呼吸性组分 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","technique_zh":"傅里叶变换红外光谱法（FT-IR）","methodology_zh":"结晶二氧化硅（石英、方石英）的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b20feb","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry i na rurki z sorbentem","methodology":"Wskaźnik narażenia jako suma iloczynów stężeń i współczynników rakotwórczości 9 rakotwórczych WWA (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia jako suma iloczynów stężeń i współczynników rakotwórczości 9 rakotwórczych WWA (z obliczeń)","reference":"PN-Z-04240-5:2006 z wyłączeniem pkt. 1, 5.6, 5.7, 5.8 | IB-76 wydanie nr 4 z dnia 02.02.2026 r.","norm_bases":["PN-Z-04240-5:2006 z wyłączeniem pkt. 1, 5.6, 5.7, 5.8","IB-76 wydanie nr 4 z dnia 02.02.2026 r."],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry i na rurki z sorbentem Wskaźnik narażenia jako suma iloczynów stężeń i współczynników rakotwórczości 9 rakotwórczych WWA (z obliczeń) PN-Z-04240-5:2006 z wyłączeniem pkt. 1, 5.6, 5.7, 5.8 | IB-76 wydanie nr 4 z dnia 02.02.2026 r. Srodowisko pracy – powietrze – probki powietrza pobrane na filtry i na rurki z sorbentem Wskaznik narazenia jako suma iloczynow stezen i wspolczynnikow rakotworczosci 9 rakotworczych WWA (z obliczen) PN-Z-04240-5:2006 z wylaczeniem pkt. 1, 5.6, 5.7, 5.8 | IB-76 wydanie nr 4 z dnia 02.02.2026 r.","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index as the sum of the products of concentrations and carcinogenicity factors of 9 carcinogenic PAHs (calculated)","search_en":"Workplace environment – air – air samples collected on filters and on sorbent tubes Exposure index as the sum of the products of concentrations and carcinogenicity factors of 9 carcinogenic PAHs (calculated) PN-Z-04240-5:2006 z wyłączeniem pkt. 1, 5.6, 5.7, 5.8 | IB-76 wydanie nr 4 z dnia 02.02.2026 r.","test_object_en":"Workplace environment – air – air samples collected on filters and on sorbent tubes"},{"_id":"6a83b7d6af14b9c0e7b20fec","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość chloru","parameters":[{"name":"Zakres","range":"(0,033 – 6,67) mg/m3"},{"name":"Zakres","range":"(0,0005 – 0,05) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość chloru\nZakres:\nZakres (0,033 – 6,67) mg/m3\nZakres (0,0005 – 0,05) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04037-03:1975","norm_bases":["PN-Z-04037-03:1975"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość chloru\nZakres:\nZakres (0,033 – 6,67) mg/m3\nZakres (0,0005 – 0,05) mg w próbce\nMetoda spektrofotometryczna PN-Z-04037-03:1975 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc chloru\nZakres:\nZakres (0,033 – 6,67) mg/m3\nZakres (0,0005 – 0,05) mg w probce\nMetoda spektrofotometryczna PN-Z-04037-03:1975","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine concentration / content","parameters_en":[{"name":"Range","range":"(0,033 – 6,67) mg/m3"},{"name":"Range","range":"(0,0005 – 0,05) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Chlorine concentration / content Spectrophotometric method Range Range PN-Z-04037-03:1975","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,033 – 6,67) mg/m3"},{"name":"范围","range":"(0,0005 – 0,05) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 氯的浓度/含量 分光光度法 范围 范围 PN-Z-04037-03:1975","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"氯的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b20fed","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość kwasu chlorowego (VII)","parameters":[{"name":"Zakres","range":"(0,31 – 100) mg/m3"},{"name":"Zakres","range":"(0,0125 – 1,25) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość kwasu chlorowego (VII)\nZakres:\nZakres (0,31 – 100) mg/m3\nZakres (0,0125 – 1,25) mg w próbce\nMetoda spektrofotometryczna","reference":"Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, str. 88 - 91","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, str. 88 - 91"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość kwasu chlorowego (VII)\nZakres:\nZakres (0,31 – 100) mg/m3\nZakres (0,0125 – 1,25) mg w próbce\nMetoda spektrofotometryczna Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, str. 88 - 91 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc kwasu chlorowego (VII)\nZakres:\nZakres (0,31 – 100) mg/m3\nZakres (0,0125 – 1,25) mg w probce\nMetoda spektrofotometryczna Podstawy i Metody Oceny Srodowiska Pracy 1997, nr 17, str. 88 - 91","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of chloric (VII) acid","parameters_en":[{"name":"Range","range":"(0,31 – 100) mg/m3"},{"name":"Range","range":"(0,0125 – 1,25) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Concentration / content of chloric (VII) acid Spectrophotometric method Range Range Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, str. 88 - 91","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,31 – 100) mg/m3"},{"name":"范围","range":"(0,0125 – 1,25) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 分光光度法 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, str. 88 - 91","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a83b7d6af14b9c0e7b20fee","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do worków","methodology":"Stężenie / zawartość:","parameters":[{"name":"propan","range":"(150 – 3600) mg/m3"},{"name":"butan","range":"(150 – 5950) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość:\nZakres:\npropan (150 – 3600) mg/m3\nbutan (150 – 5950) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"IB-101 wydanie nr 2 z dnia 14.04.2021 r.","norm_bases":["IB-101 wydanie nr 2 z dnia 14.04.2021 r."],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do worków Stężenie / zawartość:\nZakres:\npropan (150 – 3600) mg/m3\nbutan (150 – 5950) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) IB-101 wydanie nr 2 z dnia 14.04.2021 r. Srodowisko pracy – powietrze – probki powietrza pobrane do workow Stezenie / zawartosc:\nZakres:\npropan (150 – 3600) mg/m3\nbutan (150 – 5950) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) IB-101 wydanie nr 2 z dnia 14.04.2021 r.","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content:","parameters_en":[{"name":"propane","range":"(150 – 3600) mg/m3"},{"name":"butane","range":"(150 – 5950) mg/m3"}],"search_en":"Concentration / content: Gas chromatography with flame ionization detection (GC-FID) propane butane IB-101 wydanie nr 2 z dnia 14.04.2021 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","search_zh":"浓度/含量： 气相色谱-氢火焰离子化检测法（GC-FID） 丙烷 IB-101 wydanie nr 2 z dnia 14.04.2021 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"浓度/含量：","parameters_zh":[{"name":"丙烷","range":"(150 – 3600) mg/m3"},{"name":"butan","range":"(150 – 5950) mg/m3"}]},{"_id":"6a83b7d6af14b9c0e7b20fef","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Pomieszczenia – powietrze","methodology":"Pobieranie próbek w celu oznaczania stężenia:","parameters":[{"name":"substancji organicznych"},{"name":"substancji nieorganicznych"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek w celu oznaczania stężenia:\nZakres:\nsubstancji organicznych\nsubstancji nieorganicznych","reference":"PN-EN ISO 16000-1:2006 | PN-EN ISO 16000-2:2008 | IB-143 wydanie nr 1 z dnia 27.03.2025 r.","norm_bases":["PN-EN ISO 16000-1:2006","PN-EN ISO 16000-2:2008","IB-143 wydanie nr 1 z dnia 27.03.2025 r."],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia – powietrze Pobieranie próbek w celu oznaczania stężenia:\nZakres:\nsubstancji organicznych\nsubstancji nieorganicznych PN-EN ISO 16000-1:2006 | PN-EN ISO 16000-2:2008 | IB-143 wydanie nr 1 z dnia 27.03.2025 r. Pomieszczenia – powietrze Pobieranie probek w celu oznaczania stezenia:\nZakres:\nsubstancji organicznych\nsubstancji nieorganicznych PN-EN ISO 16000-1:2006 | PN-EN ISO 16000-2:2008 | IB-143 wydanie nr 1 z dnia 27.03.2025 r.","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of the concentration of:","parameters_en":[{"name":"organic substances"},{"name":"inorganic substances"}],"search_en":"Indoor spaces – air Sampling for the determination of the concentration of: organic substances inorganic substances PN-EN ISO 16000-1:2006 | PN-EN ISO 16000-2:2008 | IB-143 wydanie nr 1 z dnia 27.03.2025 r.","test_object_en":"Indoor spaces – air","parameters_zh":[{"name":"有机物质"},{"name":"无机物质"}],"search_zh":"室内 － 空气 用于测定下列浓度的采样： 有机物质 无机物质 PN-EN ISO 16000-1:2006 | PN-EN ISO 16000-2:2008 | IB-143 wydanie nr 1 z dnia 27.03.2025 r.","methodology_zh":"用于测定下列浓度的采样：","test_object_zh":"室内 － 空气"},{"_id":"6a83b7d6af14b9c0e7b20ff0","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Pomieszczenia – powietrze – próbki powietrza pobrane na rurki z sorbentem","methodology":"Stężenie / zawartość","parameters":[{"name":"formaldehydu"},{"name":"Zakres","range":"(0,0167 – 3,33) mg/m3"},{"name":"Zakres","range":"(0,0001 – 0,100) mg w próbce"},{"name":"acetaldehydu"},{"name":"Zakres","range":"(0,0167 – 3,33) mg/m3"},{"name":"Zakres","range":"(0,0001 – 0,100) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość\nZakres:\nformaldehydu\nZakres (0,0167 – 3,33) mg/m3\nZakres (0,0001 – 0,100) mg w próbce\nacetaldehydu\nZakres (0,0167 – 3,33) mg/m3\nZakres (0,0001 – 0,100) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"ISO 16000-3:2022 | IB-81 wydanie nr 8 z dnia 12.02.2026 r.","norm_bases":["ISO 16000-3:2022","IB-81 wydanie nr 8 z dnia 12.02.2026 r."],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia – powietrze – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość\nZakres:\nformaldehydu\nZakres (0,0167 – 3,33) mg/m3\nZakres (0,0001 – 0,100) mg w próbce\nacetaldehydu\nZakres (0,0167 – 3,33) mg/m3\nZakres (0,0001 – 0,100) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) ISO 16000-3:2022 | IB-81 wydanie nr 8 z dnia 12.02.2026 r. Pomieszczenia – powietrze – probki powietrza pobrane na rurki z sorbentem Stezenie / zawartosc\nZakres:\nformaldehydu\nZakres (0,0167 – 3,33) mg/m3\nZakres (0,0001 – 0,100) mg w probce\nacetaldehydu\nZakres (0,0167 – 3,33) mg/m3\nZakres (0,0001 – 0,100) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) ISO 16000-3:2022 | IB-81 wydanie nr 8 z dnia 12.02.2026 r.","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content","parameters_en":[{"name":"formaldehyde"},{"name":"Range","range":"(0,0167 – 3,33) mg/m3"},{"name":"Range","range":"(0,0001 – 0,100) mg w próbce"},{"name":"acetaldehyde"},{"name":"Range","range":"(0,0167 – 3,33) mg/m3"},{"name":"Range","range":"(0,0001 – 0,100) mg w próbce"}],"search_en":"Concentration / content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) formaldehyde Range Range acetaldehyde Range Range ISO 16000-3:2022 | IB-81 wydanie nr 8 z dnia 12.02.2026 r.","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","parameters_zh":[{"name":"甲醛"},{"name":"范围","range":"(0,0167 – 3,33) mg/m3"},{"name":"范围","range":"(0,0001 – 0,100) mg w próbce"},{"name":"acetaldehydu"},{"name":"范围","range":"(0,0167 – 3,33) mg/m3"},{"name":"范围","range":"(0,0001 – 0,100) mg w próbce"}],"search_zh":"浓度/含量 高效液相色谱-分光光度检测法（HPLC-UV） 甲醛 范围 范围 范围 范围 ISO 16000-3:2022 | IB-81 wydanie nr 8 z dnia 12.02.2026 r.","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","methodology_zh":"浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b20ff1","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – próbki powietrza pobrane na rurki z sorbentem","methodology":"Pobieranie próbek do oznaczenia stężenia formaldehydu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężenia formaldehydu","reference":"IB-81 wydanie nr 8 z dnia 12.02.2026 r.","norm_bases":["IB-81 wydanie nr 8 z dnia 12.02.2026 r."],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – próbki powietrza pobrane na rurki z sorbentem Pobieranie próbek do oznaczenia stężenia formaldehydu IB-81 wydanie nr 8 z dnia 12.02.2026 r. Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – probki powietrza pobrane na rurki z sorbentem Pobieranie probek do oznaczenia stezenia formaldehydu IB-81 wydanie nr 8 z dnia 12.02.2026 r.","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of formaldehyde concentration","search_en":"Rooms intended for human occupancy: – air – air samples collected on sorbent tubes Sampling for determination of formaldehyde concentration IB-81 wydanie nr 8 z dnia 12.02.2026 r.","test_object_en":"Rooms intended for human occupancy: – air – air samples collected on sorbent tubes","search_zh":"供人员停留的房间：－ 空气 － 采集于吸附管中的空气样品 IB-81 wydanie nr 8 z dnia 12.02.2026 r.","test_object_zh":"供人员停留的房间：－ 空气 － 采集于吸附管中的空气样品"},{"_id":"6a83b7d6af14b9c0e7b20ff2","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – próbki powietrza pobrane na rurki z sorbentem","methodology":"Stężenie / zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,2 – 200) μg/m3"},{"name":"Zakres","range":"(0,1 – 100) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość formaldehydu\nZakres:\nZakres (0,2 – 200) μg/m3\nZakres (0,1 – 100) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"IB-81 wydanie nr 8 z dnia 12.02.2026 r.","norm_bases":["IB-81 wydanie nr 8 z dnia 12.02.2026 r."],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość formaldehydu\nZakres:\nZakres (0,2 – 200) μg/m3\nZakres (0,1 – 100) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) IB-81 wydanie nr 8 z dnia 12.02.2026 r. Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – probki powietrza pobrane na rurki z sorbentem Stezenie / zawartosc formaldehydu\nZakres:\nZakres (0,2 – 200) μg/m3\nZakres (0,1 – 100) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) IB-81 wydanie nr 8 z dnia 12.02.2026 r.","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration / content","parameters_en":[{"name":"Range","range":"(0,2 – 200) μg/m3"},{"name":"Range","range":"(0,1 – 100) μg w próbce"}],"search_en":"Rooms intended for human occupancy: – air – air samples collected on sorbent tubes Formaldehyde concentration / content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Range Range IB-81 wydanie nr 8 z dnia 12.02.2026 r.","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","test_object_en":"Rooms intended for human occupancy: – air – air samples collected on sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,2 – 200) μg/m3"},{"name":"范围","range":"(0,1 – 100) μg w próbce"}],"search_zh":"供人员停留的房间：－ 空气 － 采集于吸附管中的空气样品 甲醛的浓度/含量 高效液相色谱-分光光度检测法（HPLC-UV） 范围 范围 IB-81 wydanie nr 8 z dnia 12.02.2026 r.","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","methodology_zh":"甲醛的浓度/含量","test_object_zh":"供人员停留的房间：－ 空气 － 采集于吸附管中的空气样品"},{"_id":"6a83b7d6af14b9c0e7b20ff3","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – próbki powietrza pobrane na rurki z sorbentem","methodology":"Pobieranie próbek do oznaczenia stężenia związków organicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężenia związków organicznych","reference":"IB-109 wydanie nr 4 z dnia 15.03.2024 r.","norm_bases":["IB-109 wydanie nr 4 z dnia 15.03.2024 r."],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – próbki powietrza pobrane na rurki z sorbentem Pobieranie próbek do oznaczenia stężenia związków organicznych IB-109 wydanie nr 4 z dnia 15.03.2024 r. Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – probki powietrza pobrane na rurki z sorbentem Pobieranie probek do oznaczenia stezenia zwiazkow organicznych IB-109 wydanie nr 4 z dnia 15.03.2024 r.","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of organic compound concentration","search_en":"Rooms intended for human occupancy: – air – air samples collected on sorbent tubes Sampling for the determination of organic compound concentration IB-109 wydanie nr 4 z dnia 15.03.2024 r.","test_object_en":"Rooms intended for human occupancy: – air – air samples collected on sorbent tubes","search_zh":"供人员停留的房间：－ 空气 － 采集于吸附管中的空气样品 用于测定有机化合物浓度的采样 IB-109 wydanie nr 4 z dnia 15.03.2024 r.","test_object_zh":"供人员停留的房间：－ 空气 － 采集于吸附管中的空气样品","methodology_zh":"用于测定有机化合物浓度的采样"},{"_id":"6a83b7d6af14b9c0e7b20ff4","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – próbki powietrza pobrane na rurki z sorbentem","methodology":"Stężenie / zawartość: Zakres","parameters":[{"name":"benzen","range":"(1,0 – 4000) μg/m3"},{"name":"(0,5 – 2000) μg w próbce"},{"name":"toluen","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg w próbce"},{"name":"ksylen","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg w próbce"},{"name":"etylobenzen","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg w próbce"},{"name":"octan etylu","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg w próbce"},{"name":"octan butylu","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg w próbce"},{"name":"cykloheksanon","range":"(4,0 – 4000) μg/m3"},{"name":"(2,0 – 2000) μg w próbce"},{"name":"butan-1-ol","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg w próbce"},{"name":"styren","range":"(2,0 – 4000) μg/m3"},{"name":"(1,0 – 2000) μg w próbce"},{"name":"glikol etylenowy","range":"(100,0 – 2300,0) μg/m3"},{"name":"(50,0 – 1150) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość: Zakres\nZakres:\nbenzen (1,0 – 4000) μg/m3\n(0,5 – 2000) μg w próbce\ntoluen (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w próbce\nksylen (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w próbce\netylobenzen (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w próbce\noctan etylu (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w próbce\noctan butylu (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w próbce\ncykloheksanon (4,0 – 4000) μg/m3\n(2,0 – 2000) μg w próbce\nbutan-1-ol (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w próbce\nstyren (2,0 – 4000) μg/m3\n(1,0 – 2000) μg w próbce\nglikol etylenowy (100,0 – 2300,0) μg/m3\n(50,0 – 1150) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"IB-109 wydanie nr 4 z dnia 15.03.2024 r.","norm_bases":["IB-109 wydanie nr 4 z dnia 15.03.2024 r."],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość: Zakres\nZakres:\nbenzen (1,0 – 4000) μg/m3\n(0,5 – 2000) μg w próbce\ntoluen (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w próbce\nksylen (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w próbce\netylobenzen (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w próbce\noctan etylu (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w próbce\noctan butylu (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w próbce\ncykloheksanon (4,0 – 4000) μg/m3\n(2,0 – 2000) μg w próbce\nbutan-1-ol (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w próbce\nstyren (2,0 – 4000) μg/m3\n(1,0 – 2000) μg w próbce\nglikol etylenowy (100,0 – 2300,0) μg/m3\n(50,0 – 1150) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) IB-109 wydanie nr 4 z dnia 15.03.2024 r. Pomieszczenia przeznaczone na pobyt ludzi: – powietrze – probki powietrza pobrane na rurki z sorbentem Stezenie / zawartosc: Zakres\nZakres:\nbenzen (1,0 – 4000) μg/m3\n(0,5 – 2000) μg w probce\ntoluen (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w probce\nksylen (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w probce\netylobenzen (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w probce\noctan etylu (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w probce\noctan butylu (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w probce\ncykloheksanon (4,0 – 4000) μg/m3\n(2,0 – 2000) μg w probce\nbutan-1-ol (10,0 – 4000) μg/m3\n(5,0 – 2000) μg w probce\nstyren (2,0 – 4000) μg/m3\n(1,0 – 2000) μg w probce\nglikol etylenowy (100,0 – 2300,0) μg/m3\n(50,0 – 1150) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) IB-109 wydanie nr 4 z dnia 15.03.2024 r.","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content: Range","parameters_en":[{"name":"benzene","range":"(1,0 – 4000) μg/m3"},{"name":"(0,5 – 2000) μg in the sample"},{"name":"toluene","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg in the sample"},{"name":"xylene","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg in the sample"},{"name":"ethylbenzene","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg in the sample"},{"name":"ethyl acetate","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg in the sample"},{"name":"butyl acetate","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg in the sample"},{"name":"cyclohexanone","range":"(4,0 – 4000) μg/m3"},{"name":"(2,0 – 2000) μg in the sample"},{"name":"butan-1-ol","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg in the sample"},{"name":"styrene","range":"(2,0 – 4000) μg/m3"},{"name":"(1,0 – 2000) μg in the sample"},{"name":"ethylene glycol","range":"(100,0 – 2300,0) μg/m3"},{"name":"(50,0 – 1150) μg in the sample"}],"search_en":"Rooms intended for human occupancy: – air – air samples collected on sorbent tubes Concentration / content: Range Gas chromatography with flame ionization detection (GC-FID) benzene (0,5 – 2000) μg in the sample toluene (5,0 – 2000) μg in the sample xylene (5,0 – 2000) μg in the sample ethylbenzene (5,0 – 2000) μg in the sample ethyl acetate (5,0 – 2000) μg in the sample butyl acetate (5,0 – 2000) μg in the sample cyclohexanone (2,0 – 2000) μg in the sample butan-1-ol (5,0 – 2000) μg in the sample styrene (1,0 – 2000) μg in the sample ethylene glycol (50,0 – 1150) μg in the sample IB-109 wydanie nr 4 z dnia 15.03.2024 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Rooms intended for human occupancy: – air – air samples collected on sorbent tubes","search_zh":"供人员停留的房间：－ 空气 － 采集于吸附管中的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 苯 甲苯 (5,0 – 2000) μg/样品 (5,0 – 2000) μg/样品 乙苯 (5,0 – 2000) μg/样品 乙酸乙酯 (5,0 – 2000) μg/样品 乙酸丁酯 (5,0 – 2000) μg/样品 环己酮 正丁醇 (5,0 – 2000) μg/样品 苯乙烯 IB-109 wydanie nr 4 z dnia 15.03.2024 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","parameters_zh":[{"name":"苯","range":"(1,0 – 4000) μg/m3"},{"name":"(0,5 – 2000) μg w próbce"},{"name":"甲苯","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg/样品"},{"name":"ksylen","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg/样品"},{"name":"乙苯","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg/样品"},{"name":"乙酸乙酯","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg/样品"},{"name":"乙酸丁酯","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg/样品"},{"name":"环己酮","range":"(4,0 – 4000) μg/m3"},{"name":"(2,0 – 2000) μg w próbce"},{"name":"正丁醇","range":"(10,0 – 4000) μg/m3"},{"name":"(5,0 – 2000) μg/样品"},{"name":"苯乙烯","range":"(2,0 – 4000) μg/m3"},{"name":"(1,0 – 2000) μg w próbce"},{"name":"glikol etylenowy","range":"(100,0 – 2300,0) μg/m3"},{"name":"(50,0 – 1150) μg w próbce"}],"test_object_zh":"供人员停留的房间：－ 空气 － 采集于吸附管中的空气样品"},{"_id":"6a83b7d6af14b9c0e7b20ff5","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Wody podziemne","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 60,0) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (1,0 – 60,0) oC","reference":"PN-ISO 5667-11:2017-10 | IB-34 wydanie nr 3 z dnia 02.02.2026 r.","norm_bases":["PN-ISO 5667-11:2017-10","IB-34 wydanie nr 3 z dnia 02.02.2026 r."],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody podziemne Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (1,0 – 60,0) oC PN-ISO 5667-11:2017-10 | IB-34 wydanie nr 3 z dnia 02.02.2026 r. Wody podziemne Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (1,0 – 60,0) oC PN-ISO 5667-11:2017-10 | IB-34 wydanie nr 3 z dnia 02.02.2026 r.","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 60,0) oC"}],"search_en":"Groundwater Sampling for chemical and physical testing Temperature Range PN-ISO 5667-11:2017-10 | IB-34 wydanie nr 3 z dnia 02.02.2026 r.","test_object_en":"Groundwater","parameters_zh":[{"name":"范围","range":"(1,0 – 60,0) oC"}],"search_zh":"地下水 化学和物理检测采样 温度 范围 PN-ISO 5667-11:2017-10 | IB-34 wydanie nr 3 z dnia 02.02.2026 r.","methodology_zh":"化学和物理检测采样 温度","test_object_zh":"地下水"},{"_id":"6a83b7d6af14b9c0e7b20ff6","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(1,0 – 60,0) oC"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (1,0 – 60,0) oC\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 | IB-122 wydanie nr 1 z dnia 26.01.2018 r. | IB-34 wydanie nr 3 z dnia 02.02.2026 r.","norm_bases":["PN-ISO 5667-10:2021-11","IB-122 wydanie nr 1 z dnia 26.01.2018 r.","IB-34 wydanie nr 3 z dnia 02.02.2026 r."],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (1,0 – 60,0) oC\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | IB-122 wydanie nr 1 z dnia 26.01.2018 r. | IB-34 wydanie nr 3 z dnia 02.02.2026 r. Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (1,0 – 60,0) oC\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | IB-122 wydanie nr 1 z dnia 26.01.2018 r. | IB-34 wydanie nr 3 z dnia 02.02.2026 r.","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(1,0 – 60,0) oC"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature Range PN-ISO 5667-10:2021-11 | IB-122 wydanie nr 1 z dnia 26.01.2018 r. | IB-34 wydanie nr 3 z dnia 02.02.2026 r.","technique_en":"Manual and automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(1,0 – 60,0) oC"}],"search_zh":"污水 化学与物理检测用样品采集 手工与自动法 温度 范围 PN-ISO 5667-10:2021-11 | IB-122 wydanie nr 1 z dnia 26.01.2018 r. | IB-34 wydanie nr 3 z dnia 02.02.2026 r.","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a83b7d6af14b9c0e7b20ff7","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 60,0) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (1,0 – 60,0) oC","reference":"PN-ISO 5667-5:2017-10 | IB-34 wydanie nr 3 z dnia 02.02.2026 r.","norm_bases":["PN-ISO 5667-5:2017-10","IB-34 wydanie nr 3 z dnia 02.02.2026 r."],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (1,0 – 60,0) oC PN-ISO 5667-5:2017-10 | IB-34 wydanie nr 3 z dnia 02.02.2026 r. Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (1,0 – 60,0) oC PN-ISO 5667-5:2017-10 | IB-34 wydanie nr 3 z dnia 02.02.2026 r.","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 60,0) oC"}],"search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature Range PN-ISO 5667-5:2017-10 | IB-34 wydanie nr 3 z dnia 02.02.2026 r.","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1,0 – 60,0) oC"}],"search_zh":"生活饮用水 化学和物理检测采样 温度 范围 PN-ISO 5667-5:2017-10 | IB-34 wydanie nr 3 z dnia 02.02.2026 r.","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a83b7d6af14b9c0e7b20ff8","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a83b7d6af14b9c0e7b20ff9","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Wody opadowe i wody roztopowe","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i wody roztopowe Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna PN-ISO 5667-10:2021-11 Wody opadowe i wody roztopowe Pobieranie probek do badan fizycznych i chemicznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Rainwater and snowmelt water Sampling for physical and chemical testing Manual method PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Rainwater and snowmelt water","methodology_zh":"物理与化学检测用样品采集","search_zh":"物理与化学检测用样品采集 手工法 PN-ISO 5667-10:2021-11","technique_zh":"手工法"},{"_id":"6a83b7d6af14b9c0e7b20ffa","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN ISO 10381-4:2007","norm_bases":["PN ISO 10381-4:2007"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN ISO 10381-4:2007 Gleba Pobieranie probek do badan chemicznych i fizycznych PN ISO 10381-4:2007","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing PN ISO 10381-4:2007","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN ISO 10381-4:2007","test_object_zh":"土壤"},{"_id":"6a83b7d6af14b9c0e7b20ffb","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a83b7d6af14b9c0e7b20ffc","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 11,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 11,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 2,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 11,0"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 11,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a83b7d6af14b9c0e7b20ffd","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chloru wolnego, chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego, chloru ogólnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chloru wolnego, chloru ogólnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda, scieki Stezenie chloru wolnego, chloru ogolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine, total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Water, wastewater Free chlorine, total chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"水、废水 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a83b7d6af14b9c0e7b20ffe","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,15 – 30) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,15 – 30) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks oleju mineralnego\nZakres (0,15 – 30) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego\nZakres (0,15 – 30) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,15 – 30) mg/l"}],"search_en":"Water, wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,15 – 30) mg/l"}],"search_zh":"水、废水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","methodology_zh":"矿物油指数"},{"_id":"6a83b7d6af14b9c0e7b20fff","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 3000) μS/cm"}],"search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 3000) μS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a83b7d6af14b9c0e7b21000","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Water intended for human consumption Free chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"生活饮用水 游离氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a83b7d6af14b9c0e7b21001","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Gleba","methodology":"pH - w H2O, pH - w KCl","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H2O, pH - w KCl\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH - w H2O, pH - w KCl\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH - w H2O, pH - w KCl\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H2O, pH - in KCl","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Soil pH - in H2O, pH - in KCl Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"土壤 pH － 于 H2O 中，pH － 于 KCl 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤","methodology_zh":"pH － 于 H2O 中，pH － 于 KCl 中"},{"_id":"6a83b7d6af14b9c0e7b21002","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,3 – 187) mg/m3"},{"name":"Zakres","range":"(2,0 –161) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 187) mg/m3\nZakres (2,0 –161) ppm\nMetoda elektrochemiczna","reference":"IB-129 wydanie nr 2 z dnia 14.02.2024 r.","norm_bases":["IB-129 wydanie nr 2 z dnia 14.02.2024 r."],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 187) mg/m3\nZakres (2,0 –161) ppm\nMetoda elektrochemiczna IB-129 wydanie nr 2 z dnia 14.02.2024 r. Srodowisko pracy – powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,3 – 187) mg/m3\nZakres (2,0 –161) ppm\nMetoda elektrochemiczna IB-129 wydanie nr 2 z dnia 14.02.2024 r.","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,3 – 187) mg/m3"},{"name":"Range","range":"(2,0 –161) ppm"}],"search_en":"Workplace environment – air Carbon monoxide concentration Electrochemical method Range Range IB-129 wydanie nr 2 z dnia 14.02.2024 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(2,3 – 187) mg/m3"},{"name":"范围","range":"(2,0 –161) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 范围 范围 IB-129 wydanie nr 2 z dnia 14.02.2024 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a83b7d6af14b9c0e7b21003","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie ditlenku węgla","parameters":[{"name":"Zakres","range":"(695 – 73290) mg/m3"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie ditlenku węgla\nZakres (695 – 73290) mg/m3\nMetoda elektrochemiczna","reference":"IB-129 wydanie nr 2 z dnia 14.02.2024 r.","norm_bases":["IB-129 wydanie nr 2 z dnia 14.02.2024 r."],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie ditlenku węgla\nZakres (695 – 73290) mg/m3\nMetoda elektrochemiczna IB-129 wydanie nr 2 z dnia 14.02.2024 r. Srodowisko pracy – powietrze Stezenie ditlenku wegla\nZakres (695 – 73290) mg/m3\nMetoda elektrochemiczna IB-129 wydanie nr 2 z dnia 14.02.2024 r.","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon dioxide concentration","parameters_en":[{"name":"Range","range":"(695 – 73290) mg/m3"}],"search_en":"Workplace environment – air Carbon dioxide concentration Electrochemical method Range IB-129 wydanie nr 2 z dnia 14.02.2024 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(695 – 73290) mg/m3"}],"search_zh":"工作场所环境 — 空气 二氧化碳浓度 电化学法 范围 IB-129 wydanie nr 2 z dnia 14.02.2024 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"二氧化碳浓度"},{"_id":"6a83b7d6af14b9c0e7b21004","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"IB-129 wydanie nr 2 z dnia 14.02.2024 r.","norm_bases":["IB-129 wydanie nr 2 z dnia 14.02.2024 r."],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) IB-129 wydanie nr 2 z dnia 14.02.2024 r. Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) IB-129 wydanie nr 2 z dnia 14.02.2024 r.","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) IB-129 wydanie nr 2 z dnia 14.02.2024 r.","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） IB-129 wydanie nr 2 z dnia 14.02.2024 r.","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b7d6af14b9c0e7b21005","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 – 15) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(15 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 15) °C\nWilgotność powietrza\nZakres (15 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 15) °C\nWilgotność powietrza\nZakres (15 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 15) °C\nWilgotnosc powietrza\nZakres (15 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30 – 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30 – 15) °C"},{"name":"Air humidity"},{"name":"Range","range":"(15 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5) m/s"}],"search_en":"Workplace environment – cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment – cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 – 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 – 15) °C"},{"name":"空气湿度"},{"name":"范围","range":"(15 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a83b7d6af14b9c0e7b21006","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Wskaźnik tWC, Wskaźnik IREQmin, Wskaźnik IREQneutral (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik tWC, Wskaźnik IREQmin, Wskaźnik IREQneutral (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik tWC, Wskaźnik IREQmin, Wskaźnik IREQneutral (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Wskaznik tWC, Wskaznik IREQmin, Wskaznik IREQneutral (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"tWC index, IREQmin index, IREQneutral index (calculated)","search_en":"Workplace environment – cold microclimate tWC index, IREQmin index, IREQneutral index (calculated) PN-EN ISO 11079:2008","test_object_en":"Workplace environment – cold microclimate","search_zh":"工作场所环境 — 低温微气候 tWC 指数、IREQmin 指数、IREQneutral 指数（由计算得出） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"tWC 指数、IREQmin 指数、IREQneutral 指数（由计算得出）"},{"_id":"6a83b7d6af14b9c0e7b21007","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(15 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nWilgotność powietrza\nZakres (15 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nWilgotność powietrza\nZakres (15 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nWilgotnosc powietrza\nZakres (15 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 50) °C"},{"name":"Air humidity"},{"name":"Range","range":"(15 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5) m/s"}],"search_en":"Workplace environment – moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 50) °C"},{"name":"空气湿度"},{"name":"范围","range":"(15 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83b7d6af14b9c0e7b21008","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83b7d6af14b9c0e7b21009","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 90) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 90) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 90) °C\nTemperatura wilgotna naturalna\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (10 – 90) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01","PN-EN ISO 7243:2018-01/Ap2:2020-04"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 – 90) °C\nTemperatura wilgotna naturalna\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (10 – 90) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 Srodowisko pracy – mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 – 90) °C\nTemperatura wilgotna naturalna\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (10 – 90) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 90) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 – 50) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 90) °C"}],"search_en":"Workplace environment – hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 90) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 – 50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 90) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83b7d6af14b9c0e7b2100a","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01","PN-EN ISO 7243:2018-01/Ap2:2020-04"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 Srodowisko pracy – mikroklimat goracy Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGTeff index (calculated)","search_en":"Workplace environment – hot microclimate WBGTeff index (calculated) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","test_object_en":"Workplace environment – hot microclimate","search_zh":"工作场所环境 — 高温微气候 WBGTeff 指数（由计算得出） PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","test_object_zh":"工作场所环境 — 高温微气候","methodology_zh":"WBGTeff 指数（由计算得出）"},{"_id":"6a83b7d6af14b9c0e7b2100b","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"IB-62 wydanie nr 3 z dnia 16.03.2026 r.","norm_bases":["IB-62 wydanie nr 3 z dnia 16.03.2026 r."],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 10000) lx\nMetoda pomiarowa bezpośrednia IB-62 wydanie nr 3 z dnia 16.03.2026 r. Srodowisko pracy – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 10000) lx\nMetoda pomiarowa bezposrednia IB-62 wydanie nr 3 z dnia 16.03.2026 r.","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 10000) lx"}],"search_en":"Workplace environment – indoor electric lighting Illuminance Direct measurement method Range IB-62 wydanie nr 3 z dnia 16.03.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 10000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 IB-62 wydanie nr 3 z dnia 16.03.2026 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b7d6af14b9c0e7b2100c","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"IB-62 wydanie nr 3 z dnia 16.03.2026 r.","norm_bases":["IB-62 wydanie nr 3 z dnia 16.03.2026 r."],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) IB-62 wydanie nr 3 z dnia 16.03.2026 r. Srodowisko pracy – oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) IB-62 wydanie nr 3 z dnia 16.03.2026 r.","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment – indoor electric lighting Illuminance uniformity (calculated) IB-62 wydanie nr 3 z dnia 16.03.2026 r.","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） IB-62 wydanie nr 3 z dnia 16.03.2026 r.","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b7d6af14b9c0e7b2100d","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,2 – 500) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,2 – 500) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,2 – 500) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,2 – 500) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,2 – 500) m/s2"}],"search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,2 – 500) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a83b7d6af14b9c0e7b2100e","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）"},{"_id":"6a83b7d6af14b9c0e7b2100f","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,03 – 120) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 120) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 120) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,03 – 120) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,03 – 120) m/s2"}],"search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,03 – 120) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a83b7d6af14b9c0e7b21010","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）"},{"_id":"6a83b7d6af14b9c0e7b21011","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22,0 – 136,0) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(50,0 – 139,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (22,0 – 136,0) dB\nSzczytowy poziom dźwięku C\nZakres (50,0 – 139,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (22,0 – 136,0) dB\nSzczytowy poziom dźwięku C\nZakres (50,0 – 139,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (22,0 – 136,0) dB\nSzczytowy poziom dzwieku C\nZakres (50,0 – 139,0) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkty 10 i 11","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(22,0 – 136,0) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(50,0 – 139,0) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(22,0 – 136,0) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(50,0 – 139,0) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b7d6af14b9c0e7b21012","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkty 10 i 11","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkty 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b7d6af14b9c0e7b21013","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(55 - 138) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(55 - 143) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (55 - 138) dB\nSzczytowy poziom dźwięku C\nZakres (55 - 143) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 strategia nr 3","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 strategia nr 3"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (55 - 138) dB\nSzczytowy poziom dźwięku C\nZakres (55 - 143) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 strategia nr 3 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (55 - 138) dB\nSzczytowy poziom dzwieku C\nZakres (55 - 143) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 strategia nr 3","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(55 - 138) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(55 - 143) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 strategia nr 3","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(55 - 138) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(55 - 143) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 strategia nr 3","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b7d6af14b9c0e7b21014","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 strategia nr 3","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 strategia nr 3"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 strategia nr 3 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 strategia nr 3","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 strategia nr 3","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2025-11 strategia nr 3","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b7d6af14b9c0e7b21015","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz","parameters":[{"name":"Zakres","range":"(49 – 161) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (49 – 161) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (49 – 161) dB\nMetoda pomiarowa bezpośrednia PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Maksymalne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz\nZakres (49 – 161) dB\nMetoda pomiarowa bezposrednia PN-Z-01339:2020-12","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz","parameters_en":[{"name":"Range","range":"(49 – 161) dB"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Direct measurement method Range PN-Z-01339:2020-12","technique_en":"Direct measurement method","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"范围","range":"(49 – 161) dB"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级 直接测量法 范围 PN-Z-01339:2020-12","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级"},{"_id":"6a83b7d6af14b9c0e7b21016","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:","parameters":[{"name":"8 - godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-Z-01339:2020-12","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to: an 8-hour daily working time the average weekly working time (calculated) PN-Z-01339:2020-12","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"每日 8 小时工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照下列条件： 每日 8 小时工作时间 平均每周工作时间（计算值） PN-Z-01339:2020-12","test_object_zh":"工作场所环境 — 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照下列条件："},{"_id":"6a83b7d6af14b9c0e7b21017","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3","PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Równoważny poziom dźwięku A\nZakres (24 – 136) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia – halas Rownowazny poziom dzwieku A\nZakres (24 – 136) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3744:2011 z wylaczeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wylaczeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 – 136) dB"}],"search_en":"Machinery and equipment – noise A-weighted equivalent sound pressure level Direct measurement method Range PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment – noise","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 136) dB"}],"search_zh":"机器与设备 – 噪声 A 计权等效声级 直接测量法 范围 PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_zh":"直接测量法","test_object_zh":"机器与设备 – 噪声"},{"_id":"6a83b7d6af14b9c0e7b21018","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Poziom mocy akustycznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom mocy akustycznej (z obliczeń)","reference":"PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3","PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Poziom mocy akustycznej (z obliczeń) PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia – halas Poziom mocy akustycznej (z obliczen) PN-EN ISO 3744:2011 z wylaczeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wylaczeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound power level (calculated)","search_en":"Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","test_object_en":"Machinery and equipment – noise","search_zh":"机器与设备 – 噪声 声功率级（计算值） PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声功率级（计算值）"},{"_id":"6a83b7d6af14b9c0e7b21019","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22,0 – 136,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (22,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (22,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (22,0 – 136,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(22,0 – 136,0) dB"}],"search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment – noise from roads, railway lines, tram lines","parameters_zh":[{"name":"范围","range":"(22,0 – 136,0) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"A 计权等效声级 A 计权声暴露级"},{"_id":"6a83b7d6af14b9c0e7b2101a","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 nr 140 poz. 824) (Dz.U. 2011 nr 288, poz. 1697) z wyłączeniem punktu H","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a83b7d6af14b9c0e7b2101b","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 – 136) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 – 136) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 – 136) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 136) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a83b7d6af14b9c0e7b2101c","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a83b7d6af14b9c0e7b2101d","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A\nZakres (24 – 136) dB\nMetoda pomiarowa bezpośrednia PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A\nZakres (24 – 136) dB\nMetoda pomiarowa bezposrednia PN-87/B-02156","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 – 136) dB"}],"search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound pressure level Direct measurement method Range PN-87/B-02156","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 136) dB"}],"search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 A 计权等效声级 直接测量法 范围 PN-87/B-02156","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a83b7d6af14b9c0e7b2101e","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen) PN-87/B-02156","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level for reference time T (calculated)","search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated) PN-87/B-02156","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 参考时间 T 内的 A 计权等效声级（计算得出） PN-87/B-02156","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a83b7d6af14b9c0e7b2101f","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń","methodology":"Równoważny poziom dźwięku A, C Maksymalny poziom dźwięku A, C","parameters":[{"name":"Zakres","range":"(24 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A, C Maksymalny poziom dźwięku A, C\nZakres (24 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12","norm_bases":["PN-EN ISO 10052:2007","PN-EN ISO 10052:2007/Ap1:2010","PN-EN ISO 10052:2021-12"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń Równoważny poziom dźwięku A, C Maksymalny poziom dźwięku A, C\nZakres (24 – 136) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas pochodzacy od urzadzen wyposazenia technicznego przenikajacy do pomieszczen Rownowazny poziom dzwieku A, C Maksymalny poziom dzwieku A, C\nZakres (24 – 136) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-, C-weighted equivalent sound level A-, C-weighted maximum sound level","parameters_en":[{"name":"Range","range":"(24 – 136) dB"}],"search_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms A-, C-weighted equivalent sound level A-, C-weighted maximum sound level Direct measurement method Range PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms","parameters_zh":[{"name":"范围","range":"(24 – 136) dB"}],"search_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声 直接测量法 范围 PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声"},{"_id":"6a83b7d6af14b9c0e7b21020","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń","methodology":"Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy (z obliczeń)","reference":"PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12","norm_bases":["PN-EN ISO 10052:2007","PN-EN ISO 10052:2007/Ap1:2010","PN-EN ISO 10052:2021-12"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy (z obliczeń) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas pochodzacy od urzadzen wyposazenia technicznego przenikajacy do pomieszczen Wzorcowy rownowazny poziom dzwieku A, C dla cyklu pracy (z obliczen) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12","categories":["environment","metrology"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reference equivalent A, C sound level for the operating cycle (calculated)","search_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms Reference equivalent A, C sound level for the operating cycle (calculated) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms","search_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声 PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声"},{"_id":"6a83b7d6af14b9c0e7b21021","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń","methodology":"Wzorcowy maksymalny poziom dźwięku A, C dla cyklu pracy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wzorcowy maksymalny poziom dźwięku A, C dla cyklu pracy (z obliczeń)","reference":"PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12","norm_bases":["PN-EN ISO 10052:2007","PN-EN ISO 10052:2007/Ap1:2010","PN-EN ISO 10052:2021-12"],"lab_section":"Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń Wzorcowy maksymalny poziom dźwięku A, C dla cyklu pracy (z obliczeń) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas pochodzacy od urzadzen wyposazenia technicznego przenikajacy do pomieszczen Wzorcowy maksymalny poziom dzwieku A, C dla cyklu pracy (z obliczen) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12","categories":["environment","metrology"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reference maximum A, C sound level for the operating cycle (calculated)","search_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms Reference maximum A, C sound level for the operating cycle (calculated) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms","search_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声 PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/Ap1:2010 | PN-EN ISO 10052:2021-12","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声"},{"_id":"6a83b7d6af14b9c0e7b21022","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry – próbki powietrza pobrane na filtry i na rurki z sorbentem, Środowisko ogólne E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na filtry i na rurki z sorbentem, Pomieszczenia E – próbki powietrza – próbki powietrza pobrane na filtry i na rurki z sorbentem","methodology":"Stężenie / zawartość substancji organicznych","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość substancji organicznych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry – próbki powietrza pobrane na filtry i na rurki z sorbentem, Środowisko ogólne E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na filtry i na rurki z sorbentem, Pomieszczenia E – próbki powietrza – próbki powietrza pobrane na filtry i na rurki z sorbentem Stężenie / zawartość substancji organicznych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry – probki powietrza pobrane na filtry i na rurki z sorbentem, Srodowisko ogolne E – probki powietrza pobrane na filtry – probki powietrza pobrane na filtry i na rurki z sorbentem, Pomieszczenia E – probki powietrza – probki powietrza pobrane na filtry i na rurki z sorbentem Stezenie / zawartosc substancji organicznych\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Normy, Procedury badawcze","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of organic substances","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of organic substances High-performance liquid chromatography with fluorescence detection (HPLC-FLD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-荧光检测法（HPLC-FLD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）"},{"_id":"6a83b7d6af14b9c0e7b21023","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E – próbki gazów odlotowych pobrane na filtry","methodology":"Stężenie / zawartość substancji organicznych","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość substancji organicznych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E – próbki gazów odlotowych pobrane na filtry Stężenie / zawartość substancji organicznych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Procedury badawcze Srodowisko ogolne E – probki gazow odlotowych pobrane na filtry Stezenie / zawartosc substancji organicznych\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Procedury badawcze","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of organic substances","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of organic substances High-performance liquid chromatography with fluorescence detection (HPLC-FLD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Procedury badawcze","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-荧光检测法（HPLC-FLD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Procedury badawcze","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）"},{"_id":"6a83b7d6af14b9c0e7b21024","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem – próbki powietrza pobrane do roztworu pochłaniającego, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem","methodology":"Stężenie / zawartość substancji organicznych","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość substancji organicznych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem – próbki powietrza pobrane do roztworu pochłaniającego, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość substancji organicznych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry – probki powietrza pobrane na rurki z sorbentem – probki powietrza pobrane do roztworu pochlaniajacego, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na rurki z sorbentem – probki gazow odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – probki powietrza pobrane na rurki z sorbentem Stezenie / zawartosc substancji organicznych\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of organic substances","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of organic substances High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b21025","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem","methodology":"Stężenie / zawartość substancji organicznych","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość substancji organicznych\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość substancji organicznych\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry – probki powietrza pobrane na rurki z sorbentem, Srodowisko ogolne E – probki powietrza pobrane na filtry – probki powietrza pobrane na rurki z sorbentem, Pomieszczenia E – probki powietrza pobrane na filtry – probki powietrza pobrane na rurki z sorbentem Stezenie / zawartosc substancji organicznych\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of organic substances","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of organic substances Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21026","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E – próbki gazów odlotowych pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na filtry","methodology":"Stężenie / zawartość substancji organicznych","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość substancji organicznych\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E – próbki gazów odlotowych pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na filtry Stężenie / zawartość substancji organicznych\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Procedury badawcze Srodowisko ogolne E – probki gazow odlotowych pobrane na rurki z sorbentem – probki gazow odlotowych pobrane na filtry Stezenie / zawartosc substancji organicznych\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Procedury badawcze","categories":["environment"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of organic substances","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of organic substances Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21027","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem","methodology":"Stężenie / zawartość substancji nieorganicznych","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość substancji nieorganicznych\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na filtry – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość substancji nieorganicznych\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry – probki powietrza pobrane na rurki z sorbentem, Srodowisko ogolne E – probki powietrza pobrane na filtry – probki powietrza pobrane na rurki z sorbentem, Pomieszczenia E – probki powietrza pobrane na filtry – probki powietrza pobrane na rurki z sorbentem Stezenie / zawartosc substancji nieorganicznych\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21028","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E – próbki gazów odlotowych pobrane na filtry","methodology":"Stężenie / zawartość substancji nieorganicznych","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość substancji nieorganicznych\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E – próbki gazów odlotowych pobrane na filtry Stężenie / zawartość substancji nieorganicznych\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Procedury badawcze Srodowisko ogolne E – probki gazow odlotowych pobrane na filtry Stezenie / zawartosc substancji nieorganicznych\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Procedury badawcze","categories":["environment"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21029","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry i na rurki z sorbentem – próbki powietrza pobrane na rurki z sorbentem – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem","methodology":"Stężenie / zawartość substancji organicznych","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość substancji organicznych\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry i na rurki z sorbentem – próbki powietrza pobrane na rurki z sorbentem – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość substancji organicznych\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry i na rurki z sorbentem – probki powietrza pobrane na rurki z sorbentem – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na rurki z sorbentem – probki gazow odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – probki powietrza pobrane na rurki z sorbentem Stezenie / zawartosc substancji organicznych\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy","categories":["environment"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of organic substances","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of organic substances Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2102a","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość metali i ich związków","parameters":[],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość metali i ich związków\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość metali i ich związków\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc metali i ich zwiazkow\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) Procedury badawcze","categories":["materials","environment"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of metals and their compounds","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Workplace environment E – air – air samples collected on filters Concentration / content of metals and their compounds Microwave plasma atomic emission spectrometry (MP-AES) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Procedury badawcze","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment E – air – air samples collected on filters","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"工作环境 E － 空气 － 采集在滤膜上的空气样品 微波等离子体原子发射光谱法（MP-AES） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Procedury badawcze","technique_zh":"微波等离子体原子发射光谱法（MP-AES）","test_object_zh":"工作环境 E － 空气 － 采集在滤膜上的空气样品"},{"_id":"6a83b7d6af14b9c0e7b2102b","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze","methodology":"Stężenie: – cyny i jej związków nieorganicznych, z wyjątkiem stannanu - w przeliczeniu na Sn - frakcja wdychalna – kobaltu i jego związków nieorganicznych – w przeliczeniu na Co – tritlenku glinu - w przeliczeniu na Al","parameters":[{"name":"frakcja wdychalna,"},{"name":"frakcja respirabilna; – wodorotlenku glinu - w przeliczeniu na"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie: – cyny i jej związków nieorganicznych, z wyjątkiem stannanu - w przeliczeniu na Sn - frakcja wdychalna – kobaltu i jego związków nieorganicznych – w przeliczeniu na Co – tritlenku glinu - w przeliczeniu na Al\nZakres:\nfrakcja wdychalna,\nfrakcja respirabilna; – wodorotlenku glinu - w przeliczeniu na","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze Stężenie: – cyny i jej związków nieorganicznych, z wyjątkiem stannanu - w przeliczeniu na Sn - frakcja wdychalna – kobaltu i jego związków nieorganicznych – w przeliczeniu na Co – tritlenku glinu - w przeliczeniu na Al\nZakres:\nfrakcja wdychalna,\nfrakcja respirabilna; – wodorotlenku glinu - w przeliczeniu na Procedury badawcze Srodowisko pracy E – powietrze Stezenie: – cyny i jej zwiazkow nieorganicznych, z wyjatkiem stannanu - w przeliczeniu na Sn - frakcja wdychalna – kobaltu i jego zwiazkow nieorganicznych – w przeliczeniu na Co – tritlenku glinu - w przeliczeniu na Al\nZakres:\nfrakcja wdychalna,\nfrakcja respirabilna; – wodorotlenku glinu - w przeliczeniu na Procedury badawcze","categories":["environment"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction,"},{"name":"frakcja respirabilna; – wodorotlenku glinu - w przeliczeniu na"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Workplace environment E – air E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. inhalable fraction, Procedury badawcze","test_object_en":"Workplace environment E – air","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 可吸入性粉尘， Procedury badawcze","parameters_zh":[{"name":"可吸入性粉尘，"},{"name":"frakcja respirabilna; – wodorotlenku glinu - w przeliczeniu na"}]},{"_id":"6a83b7d6af14b9c0e7b2102c","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze","methodology":"Al","parameters":[{"name":"frakcja wdychalna,"},{"name":"frakcja respirabilna; – glinu metalicznego, glinu proszku (niestabilizowanego)"},{"name":"frakcja wdychalna,"},{"name":"frakcja respirabilna; – kadmu i jego związków nieorganicznych - w przeliczeniu na Cd"},{"name":"frakcja wdychalna – tlenków żelaza – w przeliczeniu na Fe, tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza"},{"name":"frakcja respirabilna,"},{"name":"frakcja wdychalna – manganu i jego związków nieorganicznych - w przeliczeniu na Mn"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna, – miedzi i jej związków nieorganicznych"},{"name":"w przeliczeniu na Cu – tlenku cynku - w przeliczeniu na Zn"},{"name":"frakcja wdychalna – srebra – frakcja wdychalna – ołowiu i jego związków nieorganicznych w przeliczeniu na Pb"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna, – chromu metalicznego i jego związków (chrom (II), chrom (III), chrom (VI))"},{"name":"w przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Al\nZakres:\nfrakcja wdychalna,\nfrakcja respirabilna; – glinu metalicznego, glinu proszku (niestabilizowanego)\nfrakcja wdychalna,\nfrakcja respirabilna; – kadmu i jego związków nieorganicznych - w przeliczeniu na Cd\nfrakcja wdychalna – tlenków żelaza – w przeliczeniu na Fe, tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza\nfrakcja respirabilna,\nfrakcja wdychalna – manganu i jego związków nieorganicznych - w przeliczeniu na Mn\nfrakcja wdychalna\nfrakcja respirabilna, – miedzi i jej związków nieorganicznych\nw przeliczeniu na Cu – tlenku cynku - w przeliczeniu na Zn\nfrakcja wdychalna – srebra – frakcja wdychalna – ołowiu i jego związków nieorganicznych w przeliczeniu na Pb\nfrakcja wdychalna\nfrakcja respirabilna, – chromu metalicznego i jego związków (chrom (II), chrom (III), chrom (VI))\nw przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze Al\nZakres:\nfrakcja wdychalna,\nfrakcja respirabilna; – glinu metalicznego, glinu proszku (niestabilizowanego)\nfrakcja wdychalna,\nfrakcja respirabilna; – kadmu i jego związków nieorganicznych - w przeliczeniu na Cd\nfrakcja wdychalna – tlenków żelaza – w przeliczeniu na Fe, tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza\nfrakcja respirabilna,\nfrakcja wdychalna – manganu i jego związków nieorganicznych - w przeliczeniu na Mn\nfrakcja wdychalna\nfrakcja respirabilna, – miedzi i jej związków nieorganicznych\nw przeliczeniu na Cu – tlenku cynku - w przeliczeniu na Zn\nfrakcja wdychalna – srebra – frakcja wdychalna – ołowiu i jego związków nieorganicznych w przeliczeniu na Pb\nfrakcja wdychalna\nfrakcja respirabilna, – chromu metalicznego i jego związków (chrom (II), chrom (III), chrom (VI))\nw przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) Procedury badawcze Srodowisko pracy E – powietrze Al\nZakres:\nfrakcja wdychalna,\nfrakcja respirabilna; – glinu metalicznego, glinu proszku (niestabilizowanego)\nfrakcja wdychalna,\nfrakcja respirabilna; – kadmu i jego zwiazkow nieorganicznych - w przeliczeniu na Cd\nfrakcja wdychalna – tlenkow zelaza – w przeliczeniu na Fe, tlenek zelaza (III), tlenek zelaza (II), tetratlenek trizelaza\nfrakcja respirabilna,\nfrakcja wdychalna – manganu i jego zwiazkow nieorganicznych - w przeliczeniu na Mn\nfrakcja wdychalna\nfrakcja respirabilna, – miedzi i jej zwiazkow nieorganicznych\nw przeliczeniu na Cu – tlenku cynku - w przeliczeniu na Zn\nfrakcja wdychalna – srebra – frakcja wdychalna – olowiu i jego zwiazkow nieorganicznych w przeliczeniu na Pb\nfrakcja wdychalna\nfrakcja respirabilna, – chromu metalicznego i jego zwiazkow (chrom (II), chrom (III), chrom (VI))\nw przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) Procedury badawcze","categories":["materials","environment"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Al","parameters_en":[{"name":"inhalable fraction,"},{"name":"frakcja respirabilna; – glinu metalicznego, glinu proszku (niestabilizowanego)"},{"name":"inhalable fraction,"},{"name":"frakcja respirabilna; – kadmu i jego związków nieorganicznych - w przeliczeniu na Cd"},{"name":"frakcja wdychalna – tlenków żelaza – w przeliczeniu na Fe, tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza"},{"name":"respirable fraction,"},{"name":"frakcja wdychalna – manganu i jego związków nieorganicznych - w przeliczeniu na Mn"},{"name":"inhalable fraction"},{"name":"frakcja respirabilna, – miedzi i jej związków nieorganicznych"},{"name":"w przeliczeniu na Cu – tlenku cynku - w przeliczeniu na Zn"},{"name":"frakcja wdychalna – srebra – frakcja wdychalna – ołowiu i jego związków nieorganicznych w przeliczeniu na Pb"},{"name":"inhalable fraction"},{"name":"frakcja respirabilna, – chromu metalicznego i jego związków (chrom (II), chrom (III), chrom (VI))"},{"name":"w przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Workplace environment E – air Al Microwave plasma atomic emission spectrometry (MP-AES) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. inhalable fraction, inhalable fraction, respirable fraction, inhalable fraction inhalable fraction Procedury badawcze","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment E – air","parameters_zh":[{"name":"可吸入性粉尘，"},{"name":"frakcja respirabilna; – glinu metalicznego, glinu proszku (niestabilizowanego)"},{"name":"可吸入性粉尘，"},{"name":"frakcja respirabilna; – kadmu i jego związków nieorganicznych - w przeliczeniu na Cd"},{"name":"frakcja wdychalna – tlenków żelaza – w przeliczeniu na Fe, tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza"},{"name":"呼吸性粉尘，"},{"name":"frakcja wdychalna – manganu i jego związków nieorganicznych - w przeliczeniu na Mn"},{"name":"可吸入组分"},{"name":"frakcja respirabilna, – miedzi i jej związków nieorganicznych"},{"name":"w przeliczeniu na Cu – tlenku cynku - w przeliczeniu na Zn"},{"name":"frakcja wdychalna – srebra – frakcja wdychalna – ołowiu i jego związków nieorganicznych w przeliczeniu na Pb"},{"name":"可吸入组分"},{"name":"frakcja respirabilna, – chromu metalicznego i jego związków (chrom (II), chrom (III), chrom (VI))"},{"name":"w przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu"}],"regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"Al 微波等离子体原子发射光谱法（MP-AES） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 可吸入性粉尘， 可吸入性粉尘， 呼吸性粉尘， 可吸入组分 可吸入组分 Procedury badawcze","methodology_zh":"Al","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83b7d6af14b9c0e7b2102d","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze","methodology":"Stężenie: – tlenku wapnia","parameters":[{"name":"frakcja wdychalna,"},{"name":"frakcja respirabilna – wodorotlenku wapnia"},{"name":"frakcja wdychalna,"},{"name":"frakcja respirabilna – węglanu wapnia − frakcja wdychalna – tlenku magnezu − frakcja wdychalna – dichlorku cynku - frakcja wdychalna – cyrkonu i jego związków"},{"name":"w przeliczeniu na Zr – tytanu i jego związków – w przeliczeniu na Ti – molibdenu i jego związków w przeliczeniu na Mo – antymonu i jego związków nieorganicznych z wyjątkiem stibanu"},{"name":"w przeliczeniu na Sb – wolframu – frakcja wdychalna – wolframu związki nierozpuszczalne - w przeliczeniu na W – srebra związki rozpuszczalne"},{"name":"w przeliczeniu na Ag – baru i jego związków rozpuszczalnych"},{"name":"w przeliczeniu na Ba – związków niklu, w przeliczeniu na Ni"},{"name":"frakcja wdychalna,"},{"name":"frakcja respirabilna – niklu metalicznego – wodorku litu - frakcja wdychalna – platyny metalicznej"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie: – tlenku wapnia\nZakres:\nfrakcja wdychalna,\nfrakcja respirabilna – wodorotlenku wapnia\nfrakcja wdychalna,\nfrakcja respirabilna – węglanu wapnia − frakcja wdychalna – tlenku magnezu − frakcja wdychalna – dichlorku cynku - frakcja wdychalna – cyrkonu i jego związków\nw przeliczeniu na Zr – tytanu i jego związków – w przeliczeniu na Ti – molibdenu i jego związków w przeliczeniu na Mo – antymonu i jego związków nieorganicznych z wyjątkiem stibanu\nw przeliczeniu na Sb – wolframu – frakcja wdychalna – wolframu związki nierozpuszczalne - w przeliczeniu na W – srebra związki rozpuszczalne\nw przeliczeniu na Ag – baru i jego związków rozpuszczalnych\nw przeliczeniu na Ba – związków niklu, w przeliczeniu na Ni\nfrakcja wdychalna,\nfrakcja respirabilna – niklu metalicznego – wodorku litu - frakcja wdychalna – platyny metalicznej\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze Stężenie: – tlenku wapnia\nZakres:\nfrakcja wdychalna,\nfrakcja respirabilna – wodorotlenku wapnia\nfrakcja wdychalna,\nfrakcja respirabilna – węglanu wapnia − frakcja wdychalna – tlenku magnezu − frakcja wdychalna – dichlorku cynku - frakcja wdychalna – cyrkonu i jego związków\nw przeliczeniu na Zr – tytanu i jego związków – w przeliczeniu na Ti – molibdenu i jego związków w przeliczeniu na Mo – antymonu i jego związków nieorganicznych z wyjątkiem stibanu\nw przeliczeniu na Sb – wolframu – frakcja wdychalna – wolframu związki nierozpuszczalne - w przeliczeniu na W – srebra związki rozpuszczalne\nw przeliczeniu na Ag – baru i jego związków rozpuszczalnych\nw przeliczeniu na Ba – związków niklu, w przeliczeniu na Ni\nfrakcja wdychalna,\nfrakcja respirabilna – niklu metalicznego – wodorku litu - frakcja wdychalna – platyny metalicznej\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) Procedury badawcze Srodowisko pracy E – powietrze Stezenie: – tlenku wapnia\nZakres:\nfrakcja wdychalna,\nfrakcja respirabilna – wodorotlenku wapnia\nfrakcja wdychalna,\nfrakcja respirabilna – weglanu wapnia − frakcja wdychalna – tlenku magnezu − frakcja wdychalna – dichlorku cynku - frakcja wdychalna – cyrkonu i jego zwiazkow\nw przeliczeniu na Zr – tytanu i jego zwiazkow – w przeliczeniu na Ti – molibdenu i jego zwiazkow w przeliczeniu na Mo – antymonu i jego zwiazkow nieorganicznych z wyjatkiem stibanu\nw przeliczeniu na Sb – wolframu – frakcja wdychalna – wolframu zwiazki nierozpuszczalne - w przeliczeniu na W – srebra zwiazki rozpuszczalne\nw przeliczeniu na Ag – baru i jego zwiazkow rozpuszczalnych\nw przeliczeniu na Ba – zwiazkow niklu, w przeliczeniu na Ni\nfrakcja wdychalna,\nfrakcja respirabilna – niklu metalicznego – wodorku litu - frakcja wdychalna – platyny metalicznej\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) Procedury badawcze","categories":["materials","environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction,"},{"name":"frakcja respirabilna – wodorotlenku wapnia"},{"name":"inhalable fraction,"},{"name":"frakcja respirabilna – węglanu wapnia − frakcja wdychalna – tlenku magnezu − frakcja wdychalna – dichlorku cynku - frakcja wdychalna – cyrkonu i jego związków"},{"name":"w przeliczeniu na Zr – tytanu i jego związków – w przeliczeniu na Ti – molibdenu i jego związków w przeliczeniu na Mo – antymonu i jego związków nieorganicznych z wyjątkiem stibanu"},{"name":"w przeliczeniu na Sb – wolframu – frakcja wdychalna – wolframu związki nierozpuszczalne - w przeliczeniu na W – srebra związki rozpuszczalne"},{"name":"w przeliczeniu na Ag – baru i jego związków rozpuszczalnych"},{"name":"w przeliczeniu na Ba – związków niklu, w przeliczeniu na Ni"},{"name":"inhalable fraction,"},{"name":"frakcja respirabilna – niklu metalicznego – wodorku litu - frakcja wdychalna – platyny metalicznej"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Workplace environment E – air Microwave plasma atomic emission spectrometry (MP-AES) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. inhalable fraction, inhalable fraction, inhalable fraction, Procedury badawcze","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment E – air","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"微波等离子体原子发射光谱法（MP-AES） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 可吸入性粉尘， 可吸入性粉尘， 可吸入性粉尘， Procedury badawcze","technique_zh":"微波等离子体原子发射光谱法（MP-AES）","parameters_zh":[{"name":"可吸入性粉尘，"},{"name":"frakcja respirabilna – wodorotlenku wapnia"},{"name":"可吸入性粉尘，"},{"name":"frakcja respirabilna – węglanu wapnia − frakcja wdychalna – tlenku magnezu − frakcja wdychalna – dichlorku cynku - frakcja wdychalna – cyrkonu i jego związków"},{"name":"w przeliczeniu na Zr – tytanu i jego związków – w przeliczeniu na Ti – molibdenu i jego związków w przeliczeniu na Mo – antymonu i jego związków nieorganicznych z wyjątkiem stibanu"},{"name":"w przeliczeniu na Sb – wolframu – frakcja wdychalna – wolframu związki nierozpuszczalne - w przeliczeniu na W – srebra związki rozpuszczalne"},{"name":"w przeliczeniu na Ag – baru i jego związków rozpuszczalnych"},{"name":"w przeliczeniu na Ba – związków niklu, w przeliczeniu na Ni"},{"name":"可吸入性粉尘，"},{"name":"frakcja respirabilna – niklu metalicznego – wodorku litu - frakcja wdychalna – platyny metalicznej"}]},{"_id":"6a83b7d6af14b9c0e7b2102e","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry","methodology":"Chrom metaliczny, Związki chromu (II) – w przeliczeniu na Cr(II), Związki chromu (III) - w przeliczeniu na Cr(III) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Chrom metaliczny, Związki chromu (II) – w przeliczeniu na Cr(II), Związki chromu (III) - w przeliczeniu na Cr(III) (z obliczeń)","reference":"Procedura badawcza","norm_bases":["Procedura badawcza"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry Chrom metaliczny, Związki chromu (II) – w przeliczeniu na Cr(II), Związki chromu (III) - w przeliczeniu na Cr(III) (z obliczeń) Procedura badawcza Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry Chrom metaliczny, Zwiazki chromu (II) – w przeliczeniu na Cr(II), Zwiazki chromu (III) - w przeliczeniu na Cr(III) (z obliczen) Procedura badawcza","categories":["materials","environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Workplace environment E – air – air samples collected on filters E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Procedura badawcza","test_object_en":"Workplace environment E – air – air samples collected on filters","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"工作环境 E － 空气 － 采集在滤膜上的空气样品 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Procedura badawcza","test_object_zh":"工作环境 E － 空气 － 采集在滤膜上的空气样品"},{"_id":"6a83b7d6af14b9c0e7b2102f","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – próbki powietrza pobrane na filtry","methodology":"Zawartość: – cyny i jej związków nieorganicznych, z wyjątkiem stannanu - w przeliczeniu na Sn; – tritlenku glinu - w przeliczeniu na Al, – wodorotlenku glinu - w przeliczeniu na","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość: – cyny i jej związków nieorganicznych, z wyjątkiem stannanu - w przeliczeniu na Sn; – tritlenku glinu - w przeliczeniu na Al, – wodorotlenku glinu - w przeliczeniu na","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – próbki powietrza pobrane na filtry Zawartość: – cyny i jej związków nieorganicznych, z wyjątkiem stannanu - w przeliczeniu na Sn; – tritlenku glinu - w przeliczeniu na Al, – wodorotlenku glinu - w przeliczeniu na Procedury badawcze Srodowisko pracy E – probki powietrza pobrane na filtry Zawartosc: – cyny i jej zwiazkow nieorganicznych, z wyjatkiem stannanu - w przeliczeniu na Sn; – tritlenku glinu - w przeliczeniu na Al, – wodorotlenku glinu - w przeliczeniu na Procedury badawcze","categories":["environment"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Procedury badawcze","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Procedury badawcze"},{"_id":"6a83b7d6af14b9c0e7b21030","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – próbki powietrza pobrane na filtry","methodology":"Al, – glinu metalicznego, glinu proszku (niestabilizowanego) – kadmu i jego związków nieorganicznych- w przeliczeniu na Cd – tlenków żelaza – w przeliczeniu na Fe, tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza – manganu i jego związków nieorganicznych - w przeliczeniu na Mn – miedzi i jej związków nieorganicznych - w przeliczeniu na Cu, – tlenku cynku - w przeliczeniu na Zn – srebra – ołowiu i jego związków nieorganicznych","parameters":[{"name":"w przeliczeniu na Pb – chromu metalicznego i jego związków (chrom (II), chrom (III), chrom (VI))"},{"name":"w przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu – tlenku wapnia – wodorotlenku wapnia – węglanu wapnia – tlenku magnezu – dichlorku cynku – kobaltu i jego związków nieorganicznych – w przeliczeniu na Co – cyrkonu i jego związków"},{"name":"w przeliczeniu na Zr – tytanu i jego związków – w przeliczeniu na Ti – molibdenu i jego związków w przeliczeniu na Mo – antymonu i jego związków nieorganicznych z wyjątkiem stibanu"},{"name":"w przeliczeniu na Sb"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Al, – glinu metalicznego, glinu proszku (niestabilizowanego) – kadmu i jego związków nieorganicznych- w przeliczeniu na Cd – tlenków żelaza – w przeliczeniu na Fe, tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza – manganu i jego związków nieorganicznych - w przeliczeniu na Mn – miedzi i jej związków nieorganicznych - w przeliczeniu na Cu, – tlenku cynku - w przeliczeniu na Zn – srebra – ołowiu i jego związków nieorganicznych\nZakres:\nw przeliczeniu na Pb – chromu metalicznego i jego związków (chrom (II), chrom (III), chrom (VI))\nw przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu – tlenku wapnia – wodorotlenku wapnia – węglanu wapnia – tlenku magnezu – dichlorku cynku – kobaltu i jego związków nieorganicznych – w przeliczeniu na Co – cyrkonu i jego związków\nw przeliczeniu na Zr – tytanu i jego związków – w przeliczeniu na Ti – molibdenu i jego związków w przeliczeniu na Mo – antymonu i jego związków nieorganicznych z wyjątkiem stibanu\nw przeliczeniu na Sb\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – próbki powietrza pobrane na filtry Al, – glinu metalicznego, glinu proszku (niestabilizowanego) – kadmu i jego związków nieorganicznych- w przeliczeniu na Cd – tlenków żelaza – w przeliczeniu na Fe, tlenek żelaza (III), tlenek żelaza (II), tetratlenek triżelaza – manganu i jego związków nieorganicznych - w przeliczeniu na Mn – miedzi i jej związków nieorganicznych - w przeliczeniu na Cu, – tlenku cynku - w przeliczeniu na Zn – srebra – ołowiu i jego związków nieorganicznych\nZakres:\nw przeliczeniu na Pb – chromu metalicznego i jego związków (chrom (II), chrom (III), chrom (VI))\nw przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu – tlenku wapnia – wodorotlenku wapnia – węglanu wapnia – tlenku magnezu – dichlorku cynku – kobaltu i jego związków nieorganicznych – w przeliczeniu na Co – cyrkonu i jego związków\nw przeliczeniu na Zr – tytanu i jego związków – w przeliczeniu na Ti – molibdenu i jego związków w przeliczeniu na Mo – antymonu i jego związków nieorganicznych z wyjątkiem stibanu\nw przeliczeniu na Sb\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) Procedury badawcze Srodowisko pracy E – probki powietrza pobrane na filtry Al, – glinu metalicznego, glinu proszku (niestabilizowanego) – kadmu i jego zwiazkow nieorganicznych- w przeliczeniu na Cd – tlenkow zelaza – w przeliczeniu na Fe, tlenek zelaza (III), tlenek zelaza (II), tetratlenek trizelaza – manganu i jego zwiazkow nieorganicznych - w przeliczeniu na Mn – miedzi i jej zwiazkow nieorganicznych - w przeliczeniu na Cu, – tlenku cynku - w przeliczeniu na Zn – srebra – olowiu i jego zwiazkow nieorganicznych\nZakres:\nw przeliczeniu na Pb – chromu metalicznego i jego zwiazkow (chrom (II), chrom (III), chrom (VI))\nw przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu – tlenku wapnia – wodorotlenku wapnia – weglanu wapnia – tlenku magnezu – dichlorku cynku – kobaltu i jego zwiazkow nieorganicznych – w przeliczeniu na Co – cyrkonu i jego zwiazkow\nw przeliczeniu na Zr – tytanu i jego zwiazkow – w przeliczeniu na Ti – molibdenu i jego zwiazkow w przeliczeniu na Mo – antymonu i jego zwiazkow nieorganicznych z wyjatkiem stibanu\nw przeliczeniu na Sb\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) Procedury badawcze","categories":["materials","environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"w przeliczeniu na Pb – chromu metalicznego i jego związków (chrom (II), chrom (III), chrom (VI))"},{"name":"w przeliczeniu na Cr – wodorotlenku sodu – wodorotlenku potasu – tlenku wapnia – wodorotlenku wapnia – węglanu wapnia – tlenku magnezu – dichlorku cynku – kobaltu i jego związków nieorganicznych – w przeliczeniu na Co – cyrkonu i jego związków"},{"name":"w przeliczeniu na Zr – tytanu i jego związków – w przeliczeniu na Ti – molibdenu i jego związków w przeliczeniu na Mo – antymonu i jego związków nieorganicznych z wyjątkiem stibanu"},{"name":"calculated as Sb"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Microwave plasma atomic emission spectrometry (MP-AES) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. calculated as Sb Procedury badawcze","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"微波等离子体原子发射光谱法（MP-AES） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Procedury badawcze","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83b7d6af14b9c0e7b21031","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – próbki powietrza pobrane na filtry","methodology":"Zawartość: – wolframu – wolframu związki nierozpuszczalne","parameters":[{"name":"w przeliczeniu na W – srebra związki rozpuszczalne"},{"name":"w przeliczeniu na Ag – baru i jego związków rozpuszczalnych"},{"name":"w przeliczeniu na Ba – związków niklu, w przeliczeniu na Ni – niklu metalicznego – wodorku litu – platyny metalicznej"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Zawartość: – wolframu – wolframu związki nierozpuszczalne\nZakres:\nw przeliczeniu na W – srebra związki rozpuszczalne\nw przeliczeniu na Ag – baru i jego związków rozpuszczalnych\nw przeliczeniu na Ba – związków niklu, w przeliczeniu na Ni – niklu metalicznego – wodorku litu – platyny metalicznej\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – próbki powietrza pobrane na filtry Zawartość: – wolframu – wolframu związki nierozpuszczalne\nZakres:\nw przeliczeniu na W – srebra związki rozpuszczalne\nw przeliczeniu na Ag – baru i jego związków rozpuszczalnych\nw przeliczeniu na Ba – związków niklu, w przeliczeniu na Ni – niklu metalicznego – wodorku litu – platyny metalicznej\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) Procedury badawcze Srodowisko pracy E – probki powietrza pobrane na filtry Zawartosc: – wolframu – wolframu zwiazki nierozpuszczalne\nZakres:\nw przeliczeniu na W – srebra zwiazki rozpuszczalne\nw przeliczeniu na Ag – baru i jego zwiazkow rozpuszczalnych\nw przeliczeniu na Ba – zwiazkow niklu, w przeliczeniu na Ni – niklu metalicznego – wodorku litu – platyny metalicznej\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) Procedury badawcze","categories":["materials","environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Microwave plasma atomic emission spectrometry (MP-AES) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Procedury badawcze","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"微波等离子体原子发射光谱法（MP-AES） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Procedury badawcze","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83b7d6af14b9c0e7b21032","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość fluorowodoru","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość fluorowodoru\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość fluorowodoru\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc fluorowodoru\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of hydrogen fluoride","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of hydrogen fluoride Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21033","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość fluorków w przeliczeniu na F","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość fluorków w przeliczeniu na F\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość fluorków w przeliczeniu na F\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc fluorkow w przeliczeniu na F\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of fluorides expressed as F","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of fluorides expressed as F Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21034","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość chlorowodoru","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość chlorowodoru\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość chlorowodoru\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc chlorowodoru\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration / content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Hydrogen chloride concentration / content Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"氯化氢的浓度/含量 离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b21035","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość kwasu azotowego (V)","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie/zawartość kwasu azotowego (V)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie/zawartość kwasu azotowego (V)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie/zawartosc kwasu azotowego (V)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of nitric (V) acid","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration/content of nitric (V) acid Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"硝酸(V)的浓度/含量 离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）","methodology_zh":"硝酸(V)的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b21036","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość bromowodoru","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość bromowodoru\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość bromowodoru\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc bromowodoru\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of hydrogen bromide","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of hydrogen bromide Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21037","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość kwasu fosforowego","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość kwasu fosforowego\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość kwasu fosforowego\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc kwasu fosforowego\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of phosphoric acid","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of phosphoric acid Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21038","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość kwasu siarkowego (VI) – frakcja torakalna","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość kwasu siarkowego (VI) – frakcja torakalna\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość kwasu siarkowego (VI) – frakcja torakalna\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc kwasu siarkowego (VI) – frakcja torakalna\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of sulphuric (VI) acid – thoracic fraction","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of sulphuric (VI) acid – thoracic fraction Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"硫酸(VI)的浓度/含量 － 胸腔性粉尘 离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）","methodology_zh":"硫酸(VI)的浓度/含量 － 胸腔性粉尘"},{"_id":"6a83b7d6af14b9c0e7b21039","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość ozonu","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość ozonu\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość ozonu\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc ozonu\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ozone","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of ozone Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"臭氧的浓度/含量 离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）","methodology_zh":"臭氧的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b2103a","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość ditlenku siarki","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość ditlenku siarki\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość ditlenku siarki\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc ditlenku siarki\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of sulphur dioxide","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of sulphur dioxide Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"二氧化硫的浓度/含量 离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）","methodology_zh":"二氧化硫的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b2103b","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość tlenku azotu","parameters":[{"name":"Stężenie / zawartość ditlenku azotu Stężenie / zawartość siarkowodoru"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość tlenku azotu\nStężenie / zawartość ditlenku azotu Stężenie / zawartość siarkowodoru\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość tlenku azotu\nStężenie / zawartość ditlenku azotu Stężenie / zawartość siarkowodoru\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc tlenku azotu\nStezenie / zawartosc ditlenku azotu Stezenie / zawartosc siarkowodoru\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen oxide concentration / content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Nitrogen oxide concentration / content E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"一氧化氮的浓度/含量 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","methodology_zh":"一氧化氮的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b2103c","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość kwasu mrówkowego","parameters":[{"name":"Stężenie / zawartość kwasu octowego Stężenie / zawartość kwasu propionowego"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość kwasu mrówkowego\nStężenie / zawartość kwasu octowego Stężenie / zawartość kwasu propionowego\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość kwasu mrówkowego\nStężenie / zawartość kwasu octowego Stężenie / zawartość kwasu propionowego\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc kwasu mrowkowego\nStezenie / zawartosc kwasu octowego Stezenie / zawartosc kwasu propionowego\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of formic acid","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of formic acid E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze"},{"_id":"6a83b7d6af14b9c0e7b2103d","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość trietyloaminy","parameters":[{"name":"Stężenie / zawartość trimetyloaminy Stężenie / zawartość dietyloaminy Stężenie/zawartość dimetyloaminy Stężenie / zawartość butyloaminy Stężenie / zawartość izopropyloaminy Stężenie / zawartość etyloaminy Stężenie / zawartość metyloaminy"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość trietyloaminy\nStężenie / zawartość trimetyloaminy Stężenie / zawartość dietyloaminy Stężenie/zawartość dimetyloaminy Stężenie / zawartość butyloaminy Stężenie / zawartość izopropyloaminy Stężenie / zawartość etyloaminy Stężenie / zawartość metyloaminy\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość trietyloaminy\nStężenie / zawartość trimetyloaminy Stężenie / zawartość dietyloaminy Stężenie/zawartość dimetyloaminy Stężenie / zawartość butyloaminy Stężenie / zawartość izopropyloaminy Stężenie / zawartość etyloaminy Stężenie / zawartość metyloaminy\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc trietyloaminy\nStezenie / zawartosc trimetyloaminy Stezenie / zawartosc dietyloaminy Stezenie/zawartosc dimetyloaminy Stezenie / zawartosc butyloaminy Stezenie / zawartosc izopropyloaminy Stezenie / zawartosc etyloaminy Stezenie / zawartosc metyloaminy\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of triethylamine","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of triethylamine E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze"},{"_id":"6a83b7d6af14b9c0e7b2103e","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość amoniaku","parameters":[{"name":"Stężenie / zawartość jodu Stężenie / zawartość cyjanowodoru w przeliczeniu na CN"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją amperometryczną (IC-AD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","Metoda chromatografii jonowej z detekcją amperometryczną (IC-AD)"],"computed":[],"activity":"Stężenie / zawartość amoniaku\nStężenie / zawartość jodu Stężenie / zawartość cyjanowodoru w przeliczeniu na CN\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją amperometryczną (IC-AD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość amoniaku\nStężenie / zawartość jodu Stężenie / zawartość cyjanowodoru w przeliczeniu na CN\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD); Metoda chromatografii jonowej z detekcją amperometryczną (IC-AD) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc amoniaku\nStezenie / zawartosc jodu Stezenie / zawartosc cyjanowodoru w przeliczeniu na CN\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD); Metoda chromatografii jonowej z detekcja amperometryczna (IC-AD) Normy, Procedury badawcze","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration / content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Ammonia concentration / content E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"氨的浓度/含量 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","methodology_zh":"氨的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b2103f","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość amidosiarczanu (VI) amonu – frakcja wdychalna","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość amidosiarczanu (VI) amonu – frakcja wdychalna\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość amidosiarczanu (VI) amonu – frakcja wdychalna\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc amidosiarczanu (VI) amonu – frakcja wdychalna\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ammonium sulfamate (VI) – inhalable fraction","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of ammonium sulfamate (VI) – inhalable fraction Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21040","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość chlorku amonu – par i frakcji wdychalnej","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość chlorku amonu – par i frakcji wdychalnej\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość chlorku amonu – par i frakcji wdychalnej\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc chlorku amonu – par i frakcji wdychalnej\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ammonium chloride – vapours and inhalable fraction","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of ammonium chloride – vapours and inhalable fraction Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21041","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość bromianu (V) potasu – frakcja wdychalna","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość bromianu (V) potasu – frakcja wdychalna\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość bromianu (V) potasu – frakcja wdychalna\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc bromianu (V) potasu – frakcja wdychalna\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of potassium bromate (V) – inhalable fraction","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of potassium bromate (V) – inhalable fraction Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21042","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem","methodology":"Stężenie / zawartość kwasu chlorooctowego","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość kwasu chlorooctowego\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość kwasu chlorooctowego\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na rurki z sorbentem, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na rurki z sorbentem – probki gazow odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – probki powietrza pobrane na rurki z sorbentem Stezenie / zawartosc kwasu chlorooctowego\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of chloroacetic acid","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of chloroacetic acid Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21043","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość kwasu szczawiowego","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość kwasu szczawiowego\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość kwasu szczawiowego\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc kwasu szczawiowego\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21044","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość tritlenku siarki","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość tritlenku siarki\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – próbki powietrza pobrane na filtry Stężenie / zawartość tritlenku siarki\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na filtry, Pomieszczenia E – probki powietrza pobrane na filtry Stezenie / zawartosc tritlenku siarki\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21045","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość kwasu adypinowego – frakcja wdychalna","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość kwasu adypinowego – frakcja wdychalna\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość kwasu adypinowego – frakcja wdychalna\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc kwasu adypinowego – frakcja wdychalna\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy, Procedury badawcze","categories":["environment"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Workplace environment E – air – air samples collected on filters Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment E – air – air samples collected on filters","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"工作环境 E － 空气 － 采集在滤膜上的空气样品 离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作环境 E － 空气 － 采集在滤膜上的空气样品"},{"_id":"6a83b7d6af14b9c0e7b21046","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Zawartość kwasu siarkowego","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość kwasu siarkowego\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Zawartość kwasu siarkowego\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Procedury badawcze Srodowisko ogolne E Zawartosc kwasu siarkowego\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Procedury badawcze","categories":["environment"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfuric acid content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Sulfuric acid content Ion chromatography with conductometric detection (IC-CD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Procedury badawcze","technique_en":"Ion chromatography with conductometric detection (IC-CD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"离子色谱-电导检测法（IC-CD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Procedury badawcze","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a83b7d6af14b9c0e7b21047","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość związków organicznych:","parameters":[{"name":"– 4,4’-metylenobis(fenyloizocyjanian) w przeliczeniu na grupę NCO – diizocyjanian tolueno-2,4-diylu w przeliczeniu na grupę NCO – diizocyjanian tolueno-2,6-diylu w przeliczeniu na grupę NCO – diizocyjanian heksano-1,6-diylu (sześciometylenodwuizocyjanianu) w przeliczeniu na grupę NCO – diizocyjanian 2,2`-metylenodifenylu w przeliczeniu na grupę NCO – diizocyjanian 2,4`-metylenodifenylu w przeliczeniu na grupę NCO – izocyjanian 3-izocyjanianometylo-3,5,5- trimetylocykloheksylu w przeliczeniu na grupę NCO – 4,4’-diizocyjaniandicykloheksylometanu w przeliczeniu na grupę NCO – 1,5-diizocyjanianu naftalenu w przeliczeniu na grupę NCO"},{"name":"Diizocyjaniany – w przeliczeniu na grupę"},{"name":"NCO (suma stężeń izocyjanianowych grup funkcyjnych związków diizocyjanianów)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość związków organicznych:\nZakres:\n– 4,4’-metylenobis(fenyloizocyjanian) w przeliczeniu na grupę NCO – diizocyjanian tolueno-2,4-diylu w przeliczeniu na grupę NCO – diizocyjanian tolueno-2,6-diylu w przeliczeniu na grupę NCO – diizocyjanian heksano-1,6-diylu (sześciometylenodwuizocyjanianu) w przeliczeniu na grupę NCO – diizocyjanian 2,2`-metylenodifenylu w przeliczeniu na grupę NCO – diizocyjanian 2,4`-metylenodifenylu w przeliczeniu na grupę NCO – izocyjanian 3-izocyjanianometylo-3,5,5- trimetylocykloheksylu w przeliczeniu na grupę NCO – 4,4’-diizocyjaniandicykloheksylometanu w przeliczeniu na grupę NCO – 1,5-diizocyjanianu naftalenu w przeliczeniu na grupę NCO\nDiizocyjaniany – w przeliczeniu na grupę\nNCO (suma stężeń izocyjanianowych grup funkcyjnych związków diizocyjanianów)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość związków organicznych:\nZakres:\n– 4,4’-metylenobis(fenyloizocyjanian) w przeliczeniu na grupę NCO – diizocyjanian tolueno-2,4-diylu w przeliczeniu na grupę NCO – diizocyjanian tolueno-2,6-diylu w przeliczeniu na grupę NCO – diizocyjanian heksano-1,6-diylu (sześciometylenodwuizocyjanianu) w przeliczeniu na grupę NCO – diizocyjanian 2,2`-metylenodifenylu w przeliczeniu na grupę NCO – diizocyjanian 2,4`-metylenodifenylu w przeliczeniu na grupę NCO – izocyjanian 3-izocyjanianometylo-3,5,5- trimetylocykloheksylu w przeliczeniu na grupę NCO – 4,4’-diizocyjaniandicykloheksylometanu w przeliczeniu na grupę NCO – 1,5-diizocyjanianu naftalenu w przeliczeniu na grupę NCO\nDiizocyjaniany – w przeliczeniu na grupę\nNCO (suma stężeń izocyjanianowych grup funkcyjnych związków diizocyjanianów)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc zwiazkow organicznych:\nZakres:\n– 4,4’-metylenobis(fenyloizocyjanian) w przeliczeniu na grupe NCO – diizocyjanian tolueno-2,4-diylu w przeliczeniu na grupe NCO – diizocyjanian tolueno-2,6-diylu w przeliczeniu na grupe NCO – diizocyjanian heksano-1,6-diylu (szesciometylenodwuizocyjanianu) w przeliczeniu na grupe NCO – diizocyjanian 2,2`-metylenodifenylu w przeliczeniu na grupe NCO – diizocyjanian 2,4`-metylenodifenylu w przeliczeniu na grupe NCO – izocyjanian 3-izocyjanianometylo-3,5,5- trimetylocykloheksylu w przeliczeniu na grupe NCO – 4,4’-diizocyjaniandicykloheksylometanu w przeliczeniu na grupe NCO – 1,5-diizocyjanianu naftalenu w przeliczeniu na grupe NCO\nDiizocyjaniany – w przeliczeniu na grupe\nNCO (suma stezen izocyjanianowych grup funkcyjnych zwiazkow diizocyjanianow)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Normy, Procedury badawcze","categories":["environment"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of organic compounds:","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Workplace environment E – air – air samples collected on filters Concentration / content of organic compounds: High-performance liquid chromatography with fluorescence detection (HPLC-FLD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment E – air – air samples collected on filters","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"工作环境 E － 空气 － 采集在滤膜上的空气样品 有机化合物的浓度/含量： 高效液相色谱-荧光检测法（HPLC-FLD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","methodology_zh":"有机化合物的浓度/含量：","test_object_zh":"工作环境 E － 空气 － 采集在滤膜上的空气样品"},{"_id":"6a83b7d6af14b9c0e7b21048","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość wielopierścieniowych węglowodorów aromatycznych:","parameters":[{"name":"antracen"},{"name":"benzo(a)antracen"},{"name":"chryzen"},{"name":"benzo(b)fluoranten"},{"name":"benzo(k)fluoranten"},{"name":"benzo(a)piren"},{"name":"dibenzo(a,h)antracen"},{"name":"benzo(g,h,i) perylen"},{"name":"indeno","range":"(1,2,3, -c, d) piren"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość wielopierścieniowych węglowodorów aromatycznych:\nZakres:\nantracen\nbenzo(a)antracen\nchryzen\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a)piren\ndibenzo(a,h)antracen\nbenzo(g,h,i) perylen\nindeno (1,2,3, -c, d) piren\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość wielopierścieniowych węglowodorów aromatycznych:\nZakres:\nantracen\nbenzo(a)antracen\nchryzen\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a)piren\ndibenzo(a,h)antracen\nbenzo(g,h,i) perylen\nindeno (1,2,3, -c, d) piren\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc wielopierscieniowych weglowodorow aromatycznych:\nZakres:\nantracen\nbenzo(a)antracen\nchryzen\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a)piren\ndibenzo(a,h)antracen\nbenzo(g,h,i) perylen\nindeno (1,2,3, -c, d) piren\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Normy, Procedury badawcze","categories":["environment"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of polycyclic aromatic hydrocarbons:","parameters_en":[{"name":"anthracene"},{"name":"benzo(a)anthracene"},{"name":"chrysene"},{"name":"benzo(b)fluoranthene"},{"name":"benzo(k)fluoranthene"},{"name":"benzo(a)pyrene"},{"name":"dibenzo(a,h)anthracene"},{"name":"benzo(g,h,i) perylene"},{"name":"indeno","range":"(1,2,3, -c, d) piren"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of polycyclic aromatic hydrocarbons: High-performance liquid chromatography with fluorescence detection (HPLC-FLD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. anthracene benzo(a)anthracene chrysene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene dibenzo(a,h)anthracene benzo(g,h,i) perylene indeno Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-荧光检测法（HPLC-FLD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 蒽 苯并（a）蒽 䓛 苯并（b）荧蒽 苯并（k）荧蒽 苯并（a）芘 二苯并（a,h）蒽 茚 Normy, Procedury badawcze","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","parameters_zh":[{"name":"蒽"},{"name":"苯并（a）蒽"},{"name":"䓛"},{"name":"苯并（b）荧蒽"},{"name":"苯并（k）荧蒽"},{"name":"苯并（a）芘"},{"name":"二苯并（a,h）蒽"},{"name":"benzo(g,h,i) perylen"},{"name":"茚","range":"(1,2,3, -c, d) piren"}]},{"_id":"6a83b7d6af14b9c0e7b21049","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość izocyjanianu cykloheksylu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość izocyjanianu cykloheksylu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość izocyjanianu cykloheksylu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc izocyjanianu cykloheksylu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Normy, Procedury badawcze","categories":["environment"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-荧光检测法（HPLC-FLD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）"},{"_id":"6a83b7d6af14b9c0e7b2104a","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem","methodology":"Stężenie / zawartość kwasu trichlorooctowego","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość kwasu trichlorooctowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość kwasu trichlorooctowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E – powietrze – probki powietrza pobrane na rurki z sorbentem, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na rurki z sorbentem – probki gazow odlotowych, Pomieszczenia E – probki powietrza pobrane na rurki z sorbentem Stezenie / zawartosc kwasu trichlorooctowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b2104b","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość czerwieni zasadowej 9","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość czerwieni zasadowej 9\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość czerwieni zasadowej 9\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc czerwieni zasadowej 9\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b2104c","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość:","parameters":[{"name":"formamidu"},{"name":"N-metyloformamidu"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość:\nZakres:\nformamidu\nN-metyloformamidu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość:\nZakres:\nformamidu\nN-metyloformamidu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc:\nZakres:\nformamidu\nN-metyloformamidu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content:","parameters_en":[{"name":"formamide"},{"name":"N-methylformamide"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content: High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. formamide N-methylformamide Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"浓度/含量： 高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","methodology_zh":"浓度/含量："},{"_id":"6a83b7d6af14b9c0e7b2104d","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość akrylamidu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość akrylamidu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, procedury badawcze","norm_bases":["Normy, procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość akrylamidu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, procedury badawcze Srodowisko pracy E Stezenie / zawartosc akrylamidu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, procedury badawcze","categories":["environment"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of acrylamide","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of acrylamide High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b2104e","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość tiuramu – disulfidu tetrametylotiuramu","parameters":[{"name":"frakcja wdychalna"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość tiuramu – disulfidu tetrametylotiuramu\nfrakcja wdychalna\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość tiuramu – disulfidu tetrametylotiuramu\nfrakcja wdychalna\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc tiuramu – disulfidu tetrametylotiuramu\nfrakcja wdychalna\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of thiram – tetramethylthiuram disulfide","parameters_en":[{"name":"inhalable fraction"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of thiram – tetramethylthiuram disulfide High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. inhalable fraction Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","parameters_zh":[{"name":"可吸入组分"}],"regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 可吸入组分 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b2104f","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 2,2-bis(4-hydroksyfenylo)-propanu (bisfenolu-A)","parameters":[{"name":"frakcja wdychalna"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość 2,2-bis(4-hydroksyfenylo)-propanu (bisfenolu-A)\nfrakcja wdychalna\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 2,2-bis(4-hydroksyfenylo)-propanu (bisfenolu-A)\nfrakcja wdychalna\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 2,2-bis(4-hydroksyfenylo)-propanu (bisfenolu-A)\nfrakcja wdychalna\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. inhalable fraction Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","parameters_zh":[{"name":"可吸入组分"}],"regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 可吸入组分 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b21050","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość fenoloftaleiny-frakcji wdychalnej","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość fenoloftaleiny-frakcji wdychalnej\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość fenoloftaleiny-frakcji wdychalnej\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc fenoloftaleiny-frakcji wdychalnej\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b21051","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość hydrazyny","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość hydrazyny\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość hydrazyny\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc hydrazyny\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of hydrazine","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of hydrazine High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b21052","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość kwasu benzoesowego","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość kwasu benzoesowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość kwasu benzoesowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc kwasu benzoesowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of benzoic acid","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of benzoic acid High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b21053","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość rezorcynolu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość rezorcynolu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość rezorcynolu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc rezorcynolu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of resorcinol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of resorcinol High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b21054","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość kwasu akrylowego","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość kwasu akrylowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość kwasu akrylowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc kwasu akrylowego\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of acrylic acid","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of acrylic acid High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b21055","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Stężenie/zawartość 2-aminoetanolu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie/zawartość 2-aminoetanolu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Stężenie/zawartość 2-aminoetanolu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko ogolne E Stezenie/zawartosc 2-aminoetanolu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of 2-aminoethanol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration/content of 2-aminoethanol High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b21056","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 2,2’-iminodietanolu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość 2,2’-iminodietanolu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 2,2’-iminodietanolu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 2,2’-iminodietanolu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2,2’-iminodiethanol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 2,2’-iminodiethanol High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b21057","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość:","parameters":[{"name":"etylenodiamina"},{"name":"2,2’-iminobis(etyloamina)"},{"name":"N,N’-bis","range":"(2 aminoetylo)etylenodiamina"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość:\nZakres:\netylenodiamina\n2,2’-iminobis(etyloamina)\nN,N’-bis (2 aminoetylo)etylenodiamina\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość:\nZakres:\netylenodiamina\n2,2’-iminobis(etyloamina)\nN,N’-bis (2 aminoetylo)etylenodiamina\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc:\nZakres:\netylenodiamina\n2,2’-iminobis(etyloamina)\nN,N’-bis (2 aminoetylo)etylenodiamina\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content:","parameters_en":[{"name":"ethylenediamine"},{"name":"2,2’-iminobis(ethylamine)"},{"name":"N,N’-bis","range":"(2 aminoetylo)etylenodiamina"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content: High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. ethylenediamine 2,2’-iminobis(ethylamine) N,N’-bis Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"浓度/含量： 高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","methodology_zh":"浓度/含量："},{"_id":"6a83b7d6af14b9c0e7b21058","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość: 2-cyjanoakrylanu etylu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość: 2-cyjanoakrylanu etylu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość: 2-cyjanoakrylanu etylu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc: 2-cyjanoakrylanu etylu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b21059","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość formaldehydu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość formaldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość formaldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc formaldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration / content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Formaldehyde concentration / content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"甲醛的浓度/含量 高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","methodology_zh":"甲醛的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b2105a","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Stężenie / zawartość acetaldehydu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość acetaldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Stężenie / zawartość acetaldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko ogolne E Stezenie / zawartosc acetaldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of acetaldehyde","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of acetaldehyde High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b2105b","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość glutaraldehydu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość glutaraldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość glutaraldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc glutaraldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of glutaraldehyde","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of glutaraldehyde High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b2105c","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość akrylaldehydu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość akrylaldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość akrylaldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc akrylaldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of acrylaldehyde","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of acrylaldehyde High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b2105d","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość: hydrochinonu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość: hydrochinonu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość: hydrochinonu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc: hydrochinonu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content: hydroquinone","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content: hydroquinone High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）"},{"_id":"6a83b7d6af14b9c0e7b2105e","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość propano-1,2-diolu","parameters":[{"name":"pary i frakcja wdychalna"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość propano-1,2-diolu\npary i frakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość propano-1,2-diolu\npary i frakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc propano-1,2-diolu\npary i frakcja wdychalna\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2105f","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 2-fenoksyetanolu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 2-fenoksyetanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 2-fenoksyetanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 2-fenoksyetanolu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2-phenoxyethanol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 2-phenoxyethanol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21060","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość ftalanu diizobutylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość ftalanu diizobutylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość ftalanu diizobutylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc ftalanu diizobutylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of diisobutyl phthalate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of diisobutyl phthalate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21061","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość parafiny stałej","parameters":[{"name":"frakcja wdychalna"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość parafiny stałej\nfrakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość parafiny stałej\nfrakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc parafiny stalej\nfrakcja wdychalna\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of solid paraffin","parameters_en":[{"name":"inhalable fraction"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of solid paraffin Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. inhalable fraction Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","parameters_zh":[{"name":"可吸入组分"}],"regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 可吸入组分 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21062","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość ftalanu dimetylu – frakcja wdychalna","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość ftalanu dimetylu – frakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość ftalanu dimetylu – frakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc ftalanu dimetylu – frakcja wdychalna\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of dimethyl phthalate – inhalable fraction","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of dimethyl phthalate – inhalable fraction Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21063","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość ftalanu dietylu – frakcja wdychalna","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość ftalanu dietylu – frakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość ftalanu dietylu – frakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc ftalanu dietylu – frakcja wdychalna\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of diethyl phthalate – inhalable fraction","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of diethyl phthalate – inhalable fraction Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21064","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość ftalanu dibutylu – frakcja wdychalna","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość ftalanu dibutylu – frakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość ftalanu dibutylu – frakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc ftalanu dibutylu – frakcja wdychalna\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of dibutyl phthalate – inhalable fraction","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of dibutyl phthalate – inhalable fraction Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21065","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość eteru tert-butylometylowego","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość eteru tert-butylometylowego\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość eteru tert-butylometylowego\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc eteru tert-butylometylowego\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21066","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 1,1-dichloroetanu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 1,1-dichloroetanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 1,1-dichloroetanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 1,1-dichloroetanu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 1,1-dichloroethane","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 1,1-dichloroethane Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21067","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 1,2-dichloroetanu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 1,2-dichloroetanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 1,2-dichloroetanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 1,2-dichloroetanu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 1,2-dichloroethane","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 1,2-dichloroethane Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21068","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość propano-1,3-sultonu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość propano-1,3-sultonu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość propano-1,3-sultonu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc propano-1,3-sultonu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of propane-1,3-sultone","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of propane-1,3-sultone Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21069","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość eteru tert-butyloetylowego","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość eteru tert-butyloetylowego\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość eteru tert-butyloetylowego\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc eteru tert-butyloetylowego\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2106a","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 2-metoksyetanolu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 2-metoksyetanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 2-metoksyetanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 2-metoksyetanolu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2-methoxyethanol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 2-methoxyethanol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2106b","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie /z awartość 1-etylo-2-pirolidonu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie /z awartość 1-etylo-2-pirolidonu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie /z awartość 1-etylo-2-pirolidonu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie /z awartosc 1-etylo-2-pirolidonu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2106c","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość glicerolu – frakcja wdychalna","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość glicerolu – frakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość glicerolu – frakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc glicerolu – frakcja wdychalna\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of glycerol – inhalable fraction","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of glycerol – inhalable fraction Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2106d","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 2,2'- oksydietanolu (glikolu dwuetylenowego) – frakcja wdychalna","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 2,2'- oksydietanolu (glikolu dwuetylenowego) – frakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 2,2'- oksydietanolu (glikolu dwuetylenowego) – frakcja wdychalna\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 2,2'- oksydietanolu (glikolu dwuetylenowego) – frakcja wdychalna\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2,2'- oxydiethanol (diethylene glycol) – inhalable fraction","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 2,2'- oxydiethanol (diethylene glycol) – inhalable fraction Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2106e","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość trimetylobenzenu","parameters":[{"name":"mieszaniny izomerów","range":"(1,2,3-, 1,2,4- i 1,3,5-)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość trimetylobenzenu\nmieszaniny izomerów (1,2,3-, 1,2,4- i 1,3,5-)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość trimetylobenzenu\nmieszaniny izomerów (1,2,3-, 1,2,4- i 1,3,5-)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc trimetylobenzenu\nmieszaniny izomerow (1,2,3-, 1,2,4- i 1,3,5-)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of trimethylbenzene","parameters_en":[{"name":"mixture of isomers","range":"(1,2,3-, 1,2,4- i 1,3,5-)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of trimethylbenzene Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. mixture of isomers Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 异构体混合物 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","parameters_zh":[{"name":"异构体混合物","range":"(1,2,3-, 1,2,4- i 1,3,5-)"}]},{"_id":"6a83b7d6af14b9c0e7b2106f","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość octanu 2-metoksypropylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu 2-metoksypropylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość octanu 2-metoksypropylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc octanu 2-metoksypropylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21070","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość etylotoluenu (mieszanina izomerów)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość etylotoluenu (mieszanina izomerów)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość etylotoluenu (mieszanina izomerów)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc etylotoluenu (mieszanina izomerow)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ethyltoluene (mixture of isomers)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of ethyltoluene (mixture of isomers) Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21071","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość kumenu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość kumenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość kumenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc kumenu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of cumene","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of cumene Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21072","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość propan-2-olu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość propan-2-olu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość propan-2-olu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc propan-2-olu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of propan-2-ol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of propan-2-ol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21073","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość butan-2-onu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość butan-2-onu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość butan-2-onu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc butan-2-onu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of butan-2-one","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of butan-2-one Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21074","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 4-metylopentan-2-onu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 4-metylopentan-2-onu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 4-metylopentan-2-onu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 4-metylopentan-2-onu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 4-methylpentan-2-one","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 4-methylpentan-2-one Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21075","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość octanu 2-butoksyetylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu 2-butoksyetylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość octanu 2-butoksyetylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc octanu 2-butoksyetylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2-butoxyethyl acetate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 2-butoxyethyl acetate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"乙二醇丁醚醋酸酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"乙二醇丁醚醋酸酯的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b21076","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość dichlorometanu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość dichlorometanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość dichlorometanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc dichlorometanu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of dichloromethane","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of dichloromethane Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21077","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 2-(2-butoksyetoksy)etanolu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 2-(2-butoksyetoksy)etanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 2-(2-butoksyetoksy)etanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 2-(2-butoksyetoksy)etanolu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2-(2-butoxyethoxy)ethanol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 2-(2-butoxyethoxy)ethanol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21078","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość fenylometanolu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość fenylometanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość fenylometanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc fenylometanolu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of phenylmethanol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of phenylmethanol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21079","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość glikolu etylenowego","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość glikolu etylenowego\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość glikolu etylenowego\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc glikolu etylenowego\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ethylene glycol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of ethylene glycol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2107a","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość acetonitrylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość acetonitrylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość acetonitrylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc acetonitrylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of acetonitrile","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of acetonitrile Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2107b","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość ftalanu bis(2-etyloheksylu)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość ftalanu bis(2-etyloheksylu)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość ftalanu bis(2-etyloheksylu)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc ftalanu bis(2-etyloheksylu)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of bis(2-ethylhexyl) phthalate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of bis(2-ethylhexyl) phthalate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2107c","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość cykloheksanonu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość cykloheksanonu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość cykloheksanonu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc cykloheksanonu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of cyclohexanone","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of cyclohexanone Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"环己酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"环己酮的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b2107d","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość winylotoluenu (mieszanina izomerów)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość winylotoluenu (mieszanina izomerów)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość winylotoluenu (mieszanina izomerów)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc winylotoluenu (mieszanina izomerow)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of vinyltoluene (mixture of isomers)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of vinyltoluene (mixture of isomers) Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2107e","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 1-metoksypropan-2-olu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 1-metoksypropan-2-olu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 1-metoksypropan-2-olu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 1-metoksypropan-2-olu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 1-methoxypropan-2-ol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 1-methoxypropan-2-ol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"1-甲氧基-2-丙醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"1-甲氧基-2-丙醇的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b2107f","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość styrenu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość styrenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość styrenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc styrenu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Styrene concentration / content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Styrene concentration / content Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"苯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"苯乙烯的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b21080","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość eteru dietylowego","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość eteru dietylowego\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość eteru dietylowego\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc eteru dietylowego\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of diethyl ether","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of diethyl ether Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21081","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość chloroformu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość chloroformu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość chloroformu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc chloroformu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of chloroform","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of chloroform Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"三氯甲烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"三氯甲烷的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b21082","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość octanu propylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu propylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość octanu propylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc octanu propylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of propyl acetate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of propyl acetate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21083","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość etylobenzenu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość etylobenzenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość etylobenzenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc etylobenzenu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ethylbenzene","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of ethylbenzene Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21084","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie/zawartość trichloroetenu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość trichloroetenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie/zawartość trichloroetenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie/zawartosc trichloroetenu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Trichloroethene concentration/content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Trichloroethene concentration/content Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"三氯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"三氯乙烯的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b21085","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie/zawartość tetrachloroetenu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość tetrachloroetenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie/zawartość tetrachloroetenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie/zawartosc tetrachloroetenu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tetrachloroethene concentration/content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Tetrachloroethene concentration/content Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"四氯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"四氯乙烯的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b21086","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie/zawartość tetrahydrofuranu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość tetrahydrofuranu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie/zawartość tetrahydrofuranu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie/zawartosc tetrahydrofuranu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of tetrahydrofuran","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration/content of tetrahydrofuran Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21087","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie/zawartość fenolu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość fenolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie/zawartość fenolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie/zawartosc fenolu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol concentration/content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Phenol concentration/content Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"苯酚的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"苯酚的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b21088","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie/zawartość terpentyny","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość terpentyny\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie/zawartość terpentyny\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie/zawartosc terpentyny\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turpentine concentration/content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Turpentine concentration/content Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21089","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 1-metylo-2-pirolidonu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 1-metylo-2-pirolidonu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 1-metylo-2-pirolidonu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 1-metylo-2-pirolidonu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 1-methyl-2-pyrrolidone","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 1-methyl-2-pyrrolidone Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2108a","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość pentanu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość pentanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość pentanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc pentanu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pentane concentration / content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Pentane concentration / content Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"戊烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"戊烷的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b2108b","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Stężenie / zawartość heksanu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość heksanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Stężenie / zawartość heksanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko ogolne E Stezenie / zawartosc heksanu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of hexane","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of hexane Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2108c","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość heptanu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość heptanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość heptanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc heptanu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of heptane","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of heptane Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"正庚烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"正庚烷的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b2108d","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość cykloheksanolu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość cykloheksanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość cykloheksanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc cykloheksanolu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of cyclohexanol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of cyclohexanol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2108e","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 2-furylometanolu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 2-furylometanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 2-furylometanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 2-furylometanolu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2-furylmethanol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 2-furylmethanol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2108f","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość octanu 2-metoksy-1-metyloetylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu 2-metoksy-1-metyloetylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość octanu 2-metoksy-1-metyloetylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc octanu 2-metoksy-1-metyloetylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2-methoxy-1-methylethyl acetate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 2-methoxy-1-methylethyl acetate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"丙二醇甲醚醋酸酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"丙二醇甲醚醋酸酯的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b21090","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość metylocykloheksanu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość metylocykloheksanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość metylocykloheksanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc metylocykloheksanu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of methylcyclohexane","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of methylcyclohexane Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21091","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość cykloheksanu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość cykloheksanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość cykloheksanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc cykloheksanu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of cyclohexane","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of cyclohexane Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21092","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość octanu winylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu winylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość octanu winylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc octanu winylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of vinyl acetate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of vinyl acetate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21093","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość propan-1-olu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość propan-1-olu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość propan-1-olu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc propan-1-olu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of propan-1-ol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of propan-1-ol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21094","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość chloroetenu (chlorku winylu)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość chloroetenu (chlorku winylu)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość chloroetenu (chlorku winylu)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc chloroetenu (chlorku winylu)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of chloroethene (vinyl chloride)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of chloroethene (vinyl chloride) Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21095","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość epoksyetanu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość epoksyetanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość epoksyetanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc epoksyetanu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of epoxyethane","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of epoxyethane Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21096","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość buta-1,3-dienu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość buta-1,3-dienu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość buta-1,3-dienu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc buta-1,3-dienu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of buta-1,3-diene","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of buta-1,3-diene Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21097","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 1-chloro-2,3-epoksypropanu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 1-chloro-2,3-epoksypropanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 1-chloro-2,3-epoksypropanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 1-chloro-2,3-epoksypropanu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 1-chloro-2,3-epoxypropane","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 1-chloro-2,3-epoxypropane Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b21098","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość akrylonitrylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość akrylonitrylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość akrylonitrylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc akrylonitrylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of acrylonitrile","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of acrylonitrile Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"丙烯腈的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"丙烯腈的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b21099","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 4-hydroksy-4-metylopentan-2-onu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 4-hydroksy-4-metylopentan-2-onu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 4-hydroksy-4-metylopentan-2-onu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 4-hydroksy-4-metylopentan-2-onu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 4-hydroxy-4-methylpentan-2-one","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 4-hydroxy-4-methylpentan-2-one Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2109a","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość benzyny do lakierów","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość benzyny do lakierów\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość benzyny do lakierów\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc benzyny do lakierow\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment","automotive"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of white spirit","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of white spirit Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2109b","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość nafty","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość nafty\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość nafty\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc nafty\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of kerosene","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of kerosene Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2109c","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość benzyny ekstrakcyjnej","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość benzyny ekstrakcyjnej\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość benzyny ekstrakcyjnej\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc benzyny ekstrakcyjnej\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of extraction naphtha","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of extraction naphtha Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b2109d","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość benzenu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość benzenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość benzenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc benzenu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzene concentration / content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Benzene concentration / content Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"苯的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b2109e","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość związków organicznych:","parameters":[{"name":"etanol"},{"name":"butan-1-ol"},{"name":"2-metylopropan-1-ol"},{"name":"2-etoksyetanol"},{"name":"2-butoksyetanol"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość związków organicznych:\nZakres:\netanol\nbutan-1-ol\n2-metylopropan-1-ol\n2-etoksyetanol\n2-butoksyetanol\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość związków organicznych:\nZakres:\netanol\nbutan-1-ol\n2-metylopropan-1-ol\n2-etoksyetanol\n2-butoksyetanol\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc zwiazkow organicznych:\nZakres:\netanol\nbutan-1-ol\n2-metylopropan-1-ol\n2-etoksyetanol\n2-butoksyetanol\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of organic compounds:","parameters_en":[{"name":"ethanol"},{"name":"butan-1-ol"},{"name":"2-methylpropan-1-ol"},{"name":"2-ethoxyethanol"},{"name":"2-butoxyethanol"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of organic compounds: Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. ethanol butan-1-ol 2-methylpropan-1-ol 2-ethoxyethanol 2-butoxyethanol Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"有机化合物的浓度/含量： 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 乙醇 正丁醇 异丁醇 2-乙氧基乙醇 2-丁氧基乙醇 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","parameters_zh":[{"name":"乙醇"},{"name":"正丁醇"},{"name":"异丁醇"},{"name":"2-乙氧基乙醇"},{"name":"2-丁氧基乙醇"}],"methodology_zh":"有机化合物的浓度/含量："},{"_id":"6a83b7d6af14b9c0e7b2109f","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość: (2-metoksymetyloetoksy)-propanolu","parameters":[{"name":"mieszaniny izomerów: 1","range":"(2-metoksy-1-metyloetoksy)propan-2-"},{"name":"ol, 1","range":"(2-metoksy-2-metyloetoksy)propan-2-"},{"name":"ol, 2","range":"(2-metoksy-1-metyloetoksy)propan-1-ol"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość: (2-metoksymetyloetoksy)-propanolu\nZakres:\nmieszaniny izomerów: 1 (2-metoksy-1-metyloetoksy)propan-2-\nol, 1 (2-metoksy-2-metyloetoksy)propan-2-\nol, 2 (2-metoksy-1-metyloetoksy)propan-1-ol\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość: (2-metoksymetyloetoksy)-propanolu\nZakres:\nmieszaniny izomerów: 1 (2-metoksy-1-metyloetoksy)propan-2-\nol, 1 (2-metoksy-2-metyloetoksy)propan-2-\nol, 2 (2-metoksy-1-metyloetoksy)propan-1-ol\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc: (2-metoksymetyloetoksy)-propanolu\nZakres:\nmieszaniny izomerow: 1 (2-metoksy-1-metyloetoksy)propan-2-\nol, 1 (2-metoksy-2-metyloetoksy)propan-2-\nol, 2 (2-metoksy-1-metyloetoksy)propan-1-ol\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210a0","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość związków organicznych:","parameters":[{"name":"toluen"},{"name":"ksylen - mieszanina izomerów:"},{"name":"Zakres","range":"1,2-; 1,3-; 1,4-"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość związków organicznych:\nZakres:\ntoluen\nksylen - mieszanina izomerów:\nZakres 1,2-; 1,3-; 1,4-\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość związków organicznych:\nZakres:\ntoluen\nksylen - mieszanina izomerów:\nZakres 1,2-; 1,3-; 1,4-\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc zwiazkow organicznych:\nZakres:\ntoluen\nksylen - mieszanina izomerow:\nZakres 1,2-; 1,3-; 1,4-\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of organic compounds:","parameters_en":[{"name":"toluene"},{"name":"ksylen - mieszanina izomerów:"},{"name":"Range","range":"1,2-; 1,3-; 1,4-"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of organic compounds: Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. toluene Range Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","parameters_zh":[{"name":"甲苯"},{"name":"ksylen - mieszanina izomerów:"},{"name":"范围","range":"1,2-; 1,3-; 1,4-"}],"regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"有机化合物的浓度/含量： 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 甲苯 范围 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"有机化合物的浓度/含量："},{"_id":"6a83b7d6af14b9c0e7b210a1","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość związków organicznych:","parameters":[{"name":"octan n-butylu"},{"name":"octan 2-etoksyetylu"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość związków organicznych:\nZakres:\noctan n-butylu\noctan 2-etoksyetylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość związków organicznych:\nZakres:\noctan n-butylu\noctan 2-etoksyetylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc zwiazkow organicznych:\nZakres:\noctan n-butylu\noctan 2-etoksyetylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of organic compounds:","parameters_en":[{"name":"n-butyl acetate"},{"name":"2-ethoxyethyl acetate"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of organic compounds: Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. n-butyl acetate 2-ethoxyethyl acetate Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"有机化合物的浓度/含量： 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 乙酸正丁酯 乙二醇乙醚醋酸酯 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","parameters_zh":[{"name":"乙酸正丁酯"},{"name":"乙二醇乙醚醋酸酯"}],"methodology_zh":"有机化合物的浓度/含量："},{"_id":"6a83b7d6af14b9c0e7b210a2","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość związków organicznych:","parameters":[{"name":"octan etylu"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość związków organicznych:\noctan etylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość związków organicznych:\noctan etylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc zwiazkow organicznych:\noctan etylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of organic compounds:","parameters_en":[{"name":"ethyl acetate"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of organic compounds: Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. ethyl acetate Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"有机化合物的浓度/含量： 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 乙酸乙酯 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","parameters_zh":[{"name":"乙酸乙酯"}],"methodology_zh":"有机化合物的浓度/含量："},{"_id":"6a83b7d6af14b9c0e7b210a3","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość związków organicznych:","parameters":[{"name":"aceton"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość związków organicznych:\naceton\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość związków organicznych:\naceton\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc zwiazkow organicznych:\naceton\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of organic compounds:","parameters_en":[{"name":"acetone"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of organic compounds: Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. acetone Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"有机化合物的浓度/含量： 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 丙酮 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","parameters_zh":[{"name":"丙酮"}],"methodology_zh":"有机化合物的浓度/含量："},{"_id":"6a83b7d6af14b9c0e7b210a4","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość eteru difenylowego","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość eteru difenylowego\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość eteru difenylowego\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc eteru difenylowego\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of diphenyl ether","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of diphenyl ether Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210a5","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość naftalenu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość naftalenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość naftalenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc naftalenu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Naphthalene concentration / content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Naphthalene concentration / content Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"萘的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"萘的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b210a6","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość aniliny","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość aniliny\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość aniliny\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc aniliny\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of aniline","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of aniline Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210a7","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość metanolu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość metanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość metanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc metanolu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of methanol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of methanol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210a8","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość n-oktanu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość n-oktanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość n-oktanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc n-oktanu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of n-octane","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of n-octane Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210a9","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość chlorobenzenu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość chlorobenzenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość chlorobenzenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc chlorobenzenu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorobenzene concentration / content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Chlorobenzene concentration / content Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"氯苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"氯苯的浓度/含量"},{"_id":"6a83b7d6af14b9c0e7b210aa","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość N,N-dimetyloformamidu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość N,N-dimetyloformamidu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość N,N-dimetyloformamidu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc N,N-dimetyloformamidu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210ab","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość dimetoksymetanu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość dimetoksymetanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość dimetoksymetanu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc dimetoksymetanu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210ac","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość izoprenu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość izoprenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość izoprenu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc izoprenu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210ad","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość cykloheksyloaminy","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość cykloheksyloaminy\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość cykloheksyloaminy\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc cykloheksyloaminy\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210ae","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość akrylanu metylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość akrylanu metylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość akrylanu metylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc akrylanu metylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of methyl acrylate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of methyl acrylate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210af","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość akrylanu etylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość akrylanu etylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość akrylanu etylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc akrylanu etylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ethyl acrylate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of ethyl acrylate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210b0","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość akrylanu butylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość akrylanu butylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość akrylanu butylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc akrylanu butylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of butyl acrylate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of butyl acrylate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210b1","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość akrylanu 2-etyloheksylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość akrylanu 2-etyloheksylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość akrylanu 2-etyloheksylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc akrylanu 2-etyloheksylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210b2","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość metakrylanu metylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość metakrylanu metylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość metakrylanu metylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc metakrylanu metylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of methyl methacrylate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of methyl methacrylate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210b3","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość metakrylanu butylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość metakrylanu butylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość metakrylanu butylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc metakrylanu butylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of butyl methacrylate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of butyl methacrylate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210b4","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość octanu metylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu metylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość octanu metylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc octanu metylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of methyl acetate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of methyl acetate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210b5","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość octanu izobutylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu izobutylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość octanu izobutylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc octanu izobutylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of isobutyl acetate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of isobutyl acetate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210b6","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość octanu izopropylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu izopropylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość octanu izopropylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc octanu izopropylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of isopropyl acetate","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of isopropyl acetate Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210b7","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość heptan-2-onu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość heptan-2-onu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość heptan-2-onu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc heptan-2-onu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of heptan-2-one","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of heptan-2-one Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210b8","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Stężenie / zawartość 2- metylopropan-2-olu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 2- metylopropan-2-olu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Stężenie / zawartość 2- metylopropan-2-olu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko ogolne E Stezenie / zawartosc 2- metylopropan-2-olu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2- methylpropan-2-ol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of 2- methylpropan-2-ol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210b9","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość 3a, 4, 7, 7a-tetrahydro-4,7-metanoindenu (dicyklopentadienu)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 3a, 4, 7, 7a-tetrahydro-4,7-metanoindenu (dicyklopentadienu)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość 3a, 4, 7, 7a-tetrahydro-4,7-metanoindenu (dicyklopentadienu)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc 3a, 4, 7, 7a-tetrahydro-4,7-metanoindenu (dicyklopentadienu)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210ba","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość octanu izopentylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu izopentylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość octanu izopentylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc octanu izopentylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210bb","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E – powietrze – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem","methodology":"Stężenie / zawartość 2-(Dietyloamino)etanolu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 2-(Dietyloamino)etanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E – powietrze – próbki powietrza pobrane na rurki z sorbentem, Środowisko ogólne E – próbki powietrza atmosferycznego pobrane na rurki z sorbentem – próbki gazów odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – próbki powietrza pobrane na rurki z sorbentem Stężenie / zawartość 2-(Dietyloamino)etanolu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy Srodowisko pracy E – powietrze – probki powietrza pobrane na rurki z sorbentem, Srodowisko ogolne E – probki powietrza atmosferycznego pobrane na rurki z sorbentem – probki gazow odlotowych pobrane na rurki z sorbentem, Pomieszczenia E – probki powietrza pobrane na rurki z sorbentem Stezenie / zawartosc 2-(Dietyloamino)etanolu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy","categories":["environment"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210bc","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko pracy E","methodology":"Stężenie / zawartość butan-2-olu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość butan-2-olu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko pracy E Stężenie / zawartość butan-2-olu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko pracy E Stezenie / zawartosc butan-2-olu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of butan-2-ol","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Concentration / content of butan-2-ol Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210bd","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E – próbki gazów odlotowych pobranych na rurki z sorbentem","methodology":"Zawartość związków organicznych:","parameters":[{"name":"fenol"},{"name":"2-furylometanolu"},{"name":"ftalan dimetylu"},{"name":"ftalan dietylu"},{"name":"ftalan dibutylu"},{"name":"ftalan bis","range":"(2-etyloheksylu)"},{"name":"fenylometanol"},{"name":"cykloheksyloamina"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość związków organicznych:\nZakres:\nfenol\n2-furylometanolu\nftalan dimetylu\nftalan dietylu\nftalan dibutylu\nftalan bis (2-etyloheksylu)\nfenylometanol\ncykloheksyloamina\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E – próbki gazów odlotowych pobranych na rurki z sorbentem Zawartość związków organicznych:\nZakres:\nfenol\n2-furylometanolu\nftalan dimetylu\nftalan dietylu\nftalan dibutylu\nftalan bis (2-etyloheksylu)\nfenylometanol\ncykloheksyloamina\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko ogolne E – probki gazow odlotowych pobranych na rurki z sorbentem Zawartosc zwiazkow organicznych:\nZakres:\nfenol\n2-furylometanolu\nftalan dimetylu\nftalan dietylu\nftalan dibutylu\nftalan bis (2-etyloheksylu)\nfenylometanol\ncykloheksyloamina\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic compound content:","parameters_en":[{"name":"phenol"},{"name":"2-furylmethanol"},{"name":"dimethyl phthalate"},{"name":"diethyl phthalate"},{"name":"dibutyl phthalate"},{"name":"bis phthalate","range":"(2-etyloheksylu)"},{"name":"fenylometanol"},{"name":"cykloheksyloamina"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Organic compound content: Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. phenol 2-furylmethanol dimethyl phthalate diethyl phthalate dibutyl phthalate bis phthalate Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"有机化合物含量： 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 苯酚 邻苯二甲酸二甲酯 邻苯二甲酸二乙酯 邻苯二甲酸二丁酯 邻苯二甲酸二酯 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","parameters_zh":[{"name":"苯酚"},{"name":"2-furylometanolu"},{"name":"邻苯二甲酸二甲酯"},{"name":"邻苯二甲酸二乙酯"},{"name":"邻苯二甲酸二丁酯"},{"name":"邻苯二甲酸二酯","range":"(2-etyloheksylu)"},{"name":"fenylometanol"},{"name":"cykloheksyloamina"}],"methodology_zh":"有机化合物含量："},{"_id":"6a83b7d6af14b9c0e7b210be","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Zawartość węglowodorów aromatycznych:","parameters":[{"name":"trimetylobenzen"},{"name":"etylotoluen"},{"name":"winylotoluen"},{"name":"benzen"},{"name":"toluen"},{"name":"kumen"},{"name":"ksylen"},{"name":"etylobenzen"},{"name":"styren"},{"name":"propylobenzen"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość węglowodorów aromatycznych:\nZakres:\ntrimetylobenzen\netylotoluen\nwinylotoluen\nbenzen\ntoluen\nkumen\nksylen\netylobenzen\nstyren\npropylobenzen\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Zawartość węglowodorów aromatycznych:\nZakres:\ntrimetylobenzen\netylotoluen\nwinylotoluen\nbenzen\ntoluen\nkumen\nksylen\netylobenzen\nstyren\npropylobenzen\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko ogolne E Zawartosc weglowodorow aromatycznych:\nZakres:\ntrimetylobenzen\netylotoluen\nwinylotoluen\nbenzen\ntoluen\nkumen\nksylen\netylobenzen\nstyren\npropylobenzen\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of aromatic hydrocarbons:","parameters_en":[{"name":"trimethylbenzene"},{"name":"etylotoluen"},{"name":"winylotoluen"},{"name":"benzene"},{"name":"toluene"},{"name":"cumene"},{"name":"xylene"},{"name":"ethylbenzene"},{"name":"styrene"},{"name":"propylbenzene"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Content of aromatic hydrocarbons: Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. trimethylbenzene benzene toluene cumene xylene ethylbenzene styrene propylbenzene Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 苯 甲苯 异丙苯 乙苯 苯乙烯 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","parameters_zh":[{"name":"trimetylobenzen"},{"name":"etylotoluen"},{"name":"winylotoluen"},{"name":"苯"},{"name":"甲苯"},{"name":"异丙苯"},{"name":"ksylen"},{"name":"乙苯"},{"name":"苯乙烯"},{"name":"propylobenzen"}]},{"_id":"6a83b7d6af14b9c0e7b210bf","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Zawartość związków organicznych:","parameters":[{"name":"aceton"},{"name":"butan-2-on"},{"name":"metyloizobutyloketon"},{"name":"octan etylu"},{"name":"octan butylu"},{"name":"etanol"},{"name":"butanol"},{"name":"metylopropanol"},{"name":"octan etoksyetylu"},{"name":"octan metoksypropylu","range":"(octan 2-metoksy-1-metyloetylu)"},{"name":"etoksyetanol"},{"name":"butoksyetanol"},{"name":"metoksypropanol"},{"name":"epoksyetan"},{"name":"dichlorometan"},{"name":"trichloroetylen"},{"name":"tetrachloroetylen"},{"name":"cykloheksanol"},{"name":"(benzyna ekstrakcyjna) węglowodory alifatyczne od C5 do C12"},{"name":"octan n-propylu"},{"name":"izopropanol"},{"name":"octan 2-butoksyetylu"},{"name":"n-metylopirolidon"},{"name":"kwas octowy"},{"name":"1-chloro-2,3-epoksypropan"},{"name":"alkohol diacetonowy"},{"name":"cykloheksanon"},{"name":"glikol etylenowy"},{"name":"akrylonitryl"},{"name":"tetrahydrofuran"},{"name":"metanol"},{"name":"metakrylan metylu"},{"name":"metakrylan butylu"},{"name":"terpentyna","range":"(węglowodory alifatyczne do C12)"},{"name":"cykloheksan"},{"name":"octan metylu"},{"name":"octan winylu"},{"name":"chlorobenzen"},{"name":"dimetyloformamid"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość związków organicznych:\nZakres:\naceton\nbutan-2-on\nmetyloizobutyloketon\noctan etylu\noctan butylu\netanol\nbutanol\nmetylopropanol\noctan etoksyetylu\noctan metoksypropylu (octan 2-metoksy-1-metyloetylu)\netoksyetanol\nbutoksyetanol\nmetoksypropanol\nepoksyetan\ndichlorometan\ntrichloroetylen\ntetrachloroetylen\ncykloheksanol\n(benzyna ekstrakcyjna) węglowodory alifatyczne od C5 do C12\noctan n-propylu\nizopropanol\noctan 2-butoksyetylu\nn-metylopirolidon\nkwas octowy\n1-chloro-2,3-epoksypropan\nalkohol diacetonowy\ncykloheksanon\nglikol etylenowy\nakrylonitryl\ntetrahydrofuran\nmetanol\nmetakrylan metylu\nmetakrylan butylu\nterpentyna (węglowodory alifatyczne do C12)\ncykloheksan\noctan metylu\noctan winylu\nchlorobenzen\ndimetyloformamid\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Zawartość związków organicznych:\nZakres:\naceton\nbutan-2-on\nmetyloizobutyloketon\noctan etylu\noctan butylu\netanol\nbutanol\nmetylopropanol\noctan etoksyetylu\noctan metoksypropylu (octan 2-metoksy-1-metyloetylu)\netoksyetanol\nbutoksyetanol\nmetoksypropanol\nepoksyetan\ndichlorometan\ntrichloroetylen\ntetrachloroetylen\ncykloheksanol\n(benzyna ekstrakcyjna) węglowodory alifatyczne od C5 do C12\noctan n-propylu\nizopropanol\noctan 2-butoksyetylu\nn-metylopirolidon\nkwas octowy\n1-chloro-2,3-epoksypropan\nalkohol diacetonowy\ncykloheksanon\nglikol etylenowy\nakrylonitryl\ntetrahydrofuran\nmetanol\nmetakrylan metylu\nmetakrylan butylu\nterpentyna (węglowodory alifatyczne do C12)\ncykloheksan\noctan metylu\noctan winylu\nchlorobenzen\ndimetyloformamid\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko ogolne E Zawartosc zwiazkow organicznych:\nZakres:\naceton\nbutan-2-on\nmetyloizobutyloketon\noctan etylu\noctan butylu\netanol\nbutanol\nmetylopropanol\noctan etoksyetylu\noctan metoksypropylu (octan 2-metoksy-1-metyloetylu)\netoksyetanol\nbutoksyetanol\nmetoksypropanol\nepoksyetan\ndichlorometan\ntrichloroetylen\ntetrachloroetylen\ncykloheksanol\n(benzyna ekstrakcyjna) weglowodory alifatyczne od C5 do C12\noctan n-propylu\nizopropanol\noctan 2-butoksyetylu\nn-metylopirolidon\nkwas octowy\n1-chloro-2,3-epoksypropan\nalkohol diacetonowy\ncykloheksanon\nglikol etylenowy\nakrylonitryl\ntetrahydrofuran\nmetanol\nmetakrylan metylu\nmetakrylan butylu\nterpentyna (weglowodory alifatyczne do C12)\ncykloheksan\noctan metylu\noctan winylu\nchlorobenzen\ndimetyloformamid\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment","petro"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic compound content:","parameters_en":[{"name":"acetone"},{"name":"butan-2-one"},{"name":"methyl isobutyl ketone"},{"name":"ethyl acetate"},{"name":"butyl acetate"},{"name":"ethanol"},{"name":"butanol"},{"name":"methylpropanol"},{"name":"ethoxyethyl acetate"},{"name":"methoxypropyl acetate","range":"(octan 2-metoksy-1-metyloetylu)"},{"name":"etoksyetanol"},{"name":"butoksyetanol"},{"name":"metoksypropanol"},{"name":"epoksyetan"},{"name":"dichloromethane"},{"name":"trichloroethylene"},{"name":"tetrachloroethylene"},{"name":"cyclohexanol"},{"name":"(benzyna ekstrakcyjna) węglowodory alifatyczne od C5 do C12"},{"name":"octan n-propylu"},{"name":"isopropanol"},{"name":"2-butoxyethyl acetate"},{"name":"n-metylopirolidon"},{"name":"acetic acid"},{"name":"1-chloro-2,3-epoksypropan"},{"name":"alkohol diacetonowy"},{"name":"cyclohexanone"},{"name":"ethylene glycol"},{"name":"acrylonitrile"},{"name":"tetrahydrofuran"},{"name":"methanol"},{"name":"methyl methacrylate"},{"name":"butyl methacrylate"},{"name":"turpentine","range":"(węglowodory alifatyczne do C12)"},{"name":"cyclohexane"},{"name":"methyl acetate"},{"name":"vinyl acetate"},{"name":"chlorobenzene"},{"name":"dimetyloformamid"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Organic compound content: Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. acetone butan-2-one methyl isobutyl ketone ethyl acetate butyl acetate ethanol methylpropanol ethoxyethyl acetate methoxypropyl acetate dichloromethane trichloroethylene tetrachloroethylene cyclohexanol isopropanol 2-butoxyethyl acetate acetic acid cyclohexanone ethylene glycol acrylonitrile tetrahydrofuran methanol methyl methacrylate butyl methacrylate turpentine cyclohexane methyl acetate vinyl acetate chlorobenzene Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"有机化合物含量： 气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 丙酮 丁酮 乙酸乙酯 乙酸丁酯 乙醇 二氯甲烷 三氯乙烯 四氯乙烯 乙二醇丁醚醋酸酯 乙酸 环己酮 甲醇 甲基丙烯酸甲酯 甲基丙烯酸丁酯 环己烷 乙酸甲酯 乙酸乙烯酯 氯苯 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","parameters_zh":[{"name":"丙酮"},{"name":"丁酮"},{"name":"metyloizobutyloketon"},{"name":"乙酸乙酯"},{"name":"乙酸丁酯"},{"name":"乙醇"},{"name":"butanol"},{"name":"metylopropanol"},{"name":"octan etoksyetylu"},{"name":"octan metoksypropylu","range":"(octan 2-metoksy-1-metyloetylu)"},{"name":"etoksyetanol"},{"name":"butoksyetanol"},{"name":"metoksypropanol"},{"name":"epoksyetan"},{"name":"二氯甲烷"},{"name":"三氯乙烯"},{"name":"四氯乙烯"},{"name":"cykloheksanol"},{"name":"(benzyna ekstrakcyjna) węglowodory alifatyczne od C5 do C12"},{"name":"octan n-propylu"},{"name":"izopropanol"},{"name":"乙二醇丁醚醋酸酯"},{"name":"n-metylopirolidon"},{"name":"乙酸"},{"name":"1-chloro-2,3-epoksypropan"},{"name":"alkohol diacetonowy"},{"name":"环己酮"},{"name":"glikol etylenowy"},{"name":"akrylonitryl"},{"name":"tetrahydrofuran"},{"name":"甲醇"},{"name":"甲基丙烯酸甲酯"},{"name":"甲基丙烯酸丁酯"},{"name":"terpentyna","range":"(węglowodory alifatyczne do C12)"},{"name":"环己烷"},{"name":"乙酸甲酯"},{"name":"乙酸乙烯酯"},{"name":"氯苯"},{"name":"dimetyloformamid"}],"methodology_zh":"有机化合物含量："},{"_id":"6a83b7d6af14b9c0e7b210c0","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Zawartość octanu 2-metoksypropylu (octanu metoksypropylu)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość octanu 2-metoksypropylu (octanu metoksypropylu)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Zawartość octanu 2-metoksypropylu (octanu metoksypropylu)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko ogolne E Zawartosc octanu 2-metoksypropylu (octanu metoksypropylu)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"2-methoxypropyl acetate (methoxypropyl acetate) content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"2-methoxypropyl acetate (methoxypropyl acetate) content Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210c1","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Zawartość cyjanowodoru","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją amperometryczną (IC-AD)","techniques":["Metoda chromatografii jonowej z detekcją amperometryczną (IC-AD)"],"computed":[],"activity":"Zawartość cyjanowodoru\nMetoda chromatografii jonowej z detekcją amperometryczną (IC-AD)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Zawartość cyjanowodoru\nMetoda chromatografii jonowej z detekcją amperometryczną (IC-AD) Normy, Procedury badawcze Srodowisko ogolne E Zawartosc cyjanowodoru\nMetoda chromatografii jonowej z detekcja amperometryczna (IC-AD) Normy, Procedury badawcze","categories":["environment"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen cyanide content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Hydrogen cyanide content Ion chromatography with amperometric detection (IC-AD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Ion chromatography with amperometric detection (IC-AD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"氰化氢含量 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","methodology_zh":"氰化氢含量"},{"_id":"6a83b7d6af14b9c0e7b210c2","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Zawartość chromu (VI)","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość chromu (VI)\nMetoda spektrofotometryczna","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Zawartość chromu (VI)\nMetoda spektrofotometryczna Normy, Procedury badawcze Srodowisko ogolne E Zawartosc chromu (VI)\nMetoda spektrofotometryczna Normy, Procedury badawcze","categories":["environment"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Chromium(VI) content Spectrophotometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Spectrophotometric method","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"铬(VI)含量 分光光度法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"分光光度法","methodology_zh":"铬(VI)含量"},{"_id":"6a83b7d6af14b9c0e7b210c3","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Zawartość związków organicznych:","parameters":[{"name":"4,4’-metylenobis(fenyloizocyjanianu)"},{"name":"diizocyjanianu tolueno-2,4-diylu"},{"name":"diizocyjanianu tolueno-2,6-diylu"},{"name":"diizocyjanianu heksano-1,6-diylu (sześciometylenodwuizocyjanianu)"},{"name":"diizocyjanianu 2,2`-metylenodifenylu"},{"name":"diizocyjanianu 2,4`-metylenodifenylu"},{"name":"1,5-diizocyjanianu naftalenu"},{"name":"izocyjanianu 3-izocyjanianometylo-3,5,5 trimetylocykloheksylu"},{"name":"4,4’-diizocyjanianu dicykloheksylometanu"},{"name":"izocyjanianu cykloheksylu"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość związków organicznych:\nZakres:\n4,4’-metylenobis(fenyloizocyjanianu)\ndiizocyjanianu tolueno-2,4-diylu\ndiizocyjanianu tolueno-2,6-diylu\ndiizocyjanianu heksano-1,6-diylu (sześciometylenodwuizocyjanianu)\ndiizocyjanianu 2,2`-metylenodifenylu\ndiizocyjanianu 2,4`-metylenodifenylu\n1,5-diizocyjanianu naftalenu\nizocyjanianu 3-izocyjanianometylo-3,5,5 trimetylocykloheksylu\n4,4’-diizocyjanianu dicykloheksylometanu\nizocyjanianu cykloheksylu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Zawartość związków organicznych:\nZakres:\n4,4’-metylenobis(fenyloizocyjanianu)\ndiizocyjanianu tolueno-2,4-diylu\ndiizocyjanianu tolueno-2,6-diylu\ndiizocyjanianu heksano-1,6-diylu (sześciometylenodwuizocyjanianu)\ndiizocyjanianu 2,2`-metylenodifenylu\ndiizocyjanianu 2,4`-metylenodifenylu\n1,5-diizocyjanianu naftalenu\nizocyjanianu 3-izocyjanianometylo-3,5,5 trimetylocykloheksylu\n4,4’-diizocyjanianu dicykloheksylometanu\nizocyjanianu cykloheksylu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Procedury badawcze Srodowisko ogolne E Zawartosc zwiazkow organicznych:\nZakres:\n4,4’-metylenobis(fenyloizocyjanianu)\ndiizocyjanianu tolueno-2,4-diylu\ndiizocyjanianu tolueno-2,6-diylu\ndiizocyjanianu heksano-1,6-diylu (szesciometylenodwuizocyjanianu)\ndiizocyjanianu 2,2`-metylenodifenylu\ndiizocyjanianu 2,4`-metylenodifenylu\n1,5-diizocyjanianu naftalenu\nizocyjanianu 3-izocyjanianometylo-3,5,5 trimetylocykloheksylu\n4,4’-diizocyjanianu dicykloheksylometanu\nizocyjanianu cykloheksylu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Procedury badawcze","categories":["environment"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic compound content:","parameters_en":[{"name":"4,4’-metylenobis(fenyloizocyjanianu)"},{"name":"toluene-2,4-diyl diisocyanate"},{"name":"toluene-2,6-diyl diisocyanate"},{"name":"hexane-1,6-diyl diisocyanate (hexamethylene diisocyanate)"},{"name":"diizocyjanianu 2,2`-metylenodifenylu"},{"name":"diizocyjanianu 2,4`-metylenodifenylu"},{"name":"1,5-diizocyjanianu naftalenu"},{"name":"izocyjanianu 3-izocyjanianometylo-3,5,5 trimetylocykloheksylu"},{"name":"4,4’-diizocyjanianu dicykloheksylometanu"},{"name":"izocyjanianu cykloheksylu"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Organic compound content: High-performance liquid chromatography with fluorescence detection (HPLC-FLD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. toluene-2,4-diyl diisocyanate toluene-2,6-diyl diisocyanate hexane-1,6-diyl diisocyanate (hexamethylene diisocyanate) Procedury badawcze","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"有机化合物含量： 高效液相色谱-荧光检测法（HPLC-FLD） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 甲苯-2,4-二异氰酸酯 甲苯-2,6-二异氰酸酯 Procedury badawcze","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","methodology_zh":"有机化合物含量：","parameters_zh":[{"name":"4,4’-metylenobis(fenyloizocyjanianu)"},{"name":"甲苯-2,4-二异氰酸酯"},{"name":"甲苯-2,6-二异氰酸酯"},{"name":"diizocyjanianu heksano-1,6-diylu (sześciometylenodwuizocyjanianu)"},{"name":"diizocyjanianu 2,2`-metylenodifenylu"},{"name":"diizocyjanianu 2,4`-metylenodifenylu"},{"name":"1,5-diizocyjanianu naftalenu"},{"name":"izocyjanianu 3-izocyjanianometylo-3,5,5 trimetylocykloheksylu"},{"name":"4,4’-diizocyjanianu dicykloheksylometanu"},{"name":"izocyjanianu cykloheksylu"}]},{"_id":"6a83b7d6af14b9c0e7b210c4","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Zawartość aniliny","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość aniliny\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Zawartość aniliny\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy, Procedury badawcze Srodowisko ogolne E Zawartosc aniliny\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy, Procedury badawcze","categories":["environment"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aniline content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Aniline content Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, Procedury badawcze","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, Procedury badawcze","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83b7d6af14b9c0e7b210c5","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Zawartość związków organicznych:","parameters":[{"name":"acetaldehyd"},{"name":"glutaraldehyd"},{"name":"formaldehyd"},{"name":"akrylaldehyd"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Zawartość związków organicznych:\nZakres:\nacetaldehyd\nglutaraldehyd\nformaldehyd\nakrylaldehyd\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Normy, Procedury badawcze","norm_bases":["Normy, Procedury badawcze"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Zawartość związków organicznych:\nZakres:\nacetaldehyd\nglutaraldehyd\nformaldehyd\nakrylaldehyd\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Normy, Procedury badawcze Srodowisko ogolne E Zawartosc zwiazkow organicznych:\nZakres:\nacetaldehyd\nglutaraldehyd\nformaldehyd\nakrylaldehyd\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Normy, Procedury badawcze","categories":["environment"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic compound content:","parameters_en":[{"name":"acetaldehyde"},{"name":"glutaraldehyd"},{"name":"formaldehyde"},{"name":"akrylaldehyd"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Organic compound content: High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. acetaldehyde formaldehyde Normy, Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"有机化合物含量： 高效液相色谱-分光光度检测法（HPLC-UV） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 乙醛 甲醛 Normy, Procedury badawcze","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","methodology_zh":"有机化合物含量：","parameters_zh":[{"name":"乙醛"},{"name":"glutaraldehyd"},{"name":"甲醛"},{"name":"akrylaldehyd"}]},{"_id":"6a83b7d6af14b9c0e7b210c6","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Suma węglowodorów aromatycznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma węglowodorów aromatycznych (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Suma węglowodorów aromatycznych (z obliczeń) Normy Srodowisko ogolne E Suma weglowodorow aromatycznych (z obliczen) Normy","categories":["environment"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of aromatic hydrocarbons (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Sum of aromatic hydrocarbons (calculated) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"芳香烃总量（由计算得出） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","methodology_zh":"芳香烃总量（由计算得出）"},{"_id":"6a83b7d6af14b9c0e7b210c7","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Suma węglowodorów alifatycznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma węglowodorów alifatycznych (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Suma węglowodorów alifatycznych (z obliczeń) Normy Srodowisko ogolne E Suma weglowodorow alifatycznych (z obliczen) Normy","categories":["environment"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of aliphatic hydrocarbons (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Sum of aliphatic hydrocarbons (calculated) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy"},{"_id":"6a83b7d6af14b9c0e7b210c8","lab_id":"69ad52a3de79e566650fb4b0","country":"PL","accr_number":"AB 934","accr_body":"PCA","test_object":"Środowisko ogólne E","methodology":"Zawartość związków organicznych: octanu izopentylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość związków organicznych: octanu izopentylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Ogólnochemiczna; Pracownia Chromatografii Gazowej; Zespół Pomiarów Środowiskowych i Pobierania Próbek","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środowisko ogólne E Zawartość związków organicznych: octanu izopentylu\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy Srodowisko ogolne E Zawartosc zwiazkow organicznych: octanu izopentylu\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy","categories":["environment"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"}],"has_pdf":true}