🇵🇱 ZAKŁADY CHEMICZNE „Siarkopol” TARNOBRZEG sp. z o.o. PL

PCA AB 933 • Tarnobrzeg, Poland • 16 methods

Water & wastewaterMaterials & polymers

ZAKŁADY CHEMICZNE „Siarkopol” TARNOBRZEG sp. z o.o. is a laboratory accredited by PCA under number AB 933 (Tarnobrzeg, Poland). Its accreditation scope covers 16 test methods in the following areas: Water & wastewater, Materials & polymers. Test objects include: Water, wastewater, Surface water, Wastewater, Water. Most frequently used techniques: Titrimetric method, Gravimetric method, Potentiometric method.

At a glance

  • Accreditation number: PCA AB 933
  • Methods in scope: 16
  • Types of test objects: 4
  • Techniques used: 7
  • City: Tarnobrzeg, Poland
Accreditation number
AB 933
Accreditation body
PCA
Address
LABORATORIUM KONTROLI JAKOŚCI I OCHRONY ŚRODOWISKA, ul. Chemiczna 3, 39-400 Tarnobrzeg
City
Tarnobrzeg, Poland

What this laboratory tests (4)

Analytical techniques used (7)

Laboratory locations

Accreditation scope — test methods (16)

No. Test object Methodology / Parameters Technique Reference document
Quality Control and Environmental Protection Laboratory
1 Wastewater Sampling for chemical and physical testing
Temperature Range (0,0– 40,0) °C
Manual method PN-ISO 5667-10:2021-11 | PN-77/C-04584
2 Surface water Sampling for chemical and physical testing Temperature
Range (0,0 – 40,0) °C
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6 | PN-77/C-04584
3 Water Sampling for chemical and physical testing Temperature
Range (0,0 – 40,0) °C
IB/20/ZJO/ZJ wyd. 5 z dnia 02.01.2026 r. | PN-77/C-04584
4 Water, wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
5 Water, wastewater Sulfate concentration
Range (10 − 5000) mg/l
Gravimetric method P N - I S O 9 2 8 0 : 2 0 0 2
6 Water, wastewater Chloride concentration
Range (5,0 − 400) mg/l
Titrimetric method P N - I S O 9 2 9 7 : 1 9 9 4
7 Water, wastewater Chemical oxygen demand − COD-Cr
Range (10,0 − 700) mg/l O2
Titrimetric method P N -74/C-04578.03
8 Water, wastewater Chemical oxygen demand − COD-Cr
Range (30,0 − 1000) mg/l O2
Titrimetric method P N -ISO 6060:2006
9 Water, wastewater Nitrate nitrogen concentration
Range (0,1 − 25) mg/l
Spectrophotometric method P N - 8 2 / C - 0 4 5 7 6 - 0 8
10 Water, wastewater Total phosphorus concentration
Range (0,01 − 20,0) mg/l
Spectrophotometric method P N - E N I S O 6878:2006 p. 7 +Ap1:2010+Ap2:2010
11 Water, wastewater Total suspended solids (TSS)
Range (2,0 − 6000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
12 Water, wastewater Fluoride concentration
Range (0,1 − 1000) mg/l
Potentiometric method PN-78/C-04588.03
13 Water, wastewater Biochemical oxygen demand − BOD5
Range (0,5 − 6,0) mg/l O2
Titrimetric method P N -EN 1899-2:2002
14 Water, wastewater Biochemical oxygen demand − BOD5
Range (1,0 − 600,0) mg/l O2
Titrimetric method P N -EN ISO 5815-1:2019-12
15 Water, wastewater Anion concentrations
chlorides (5 – 4000) mg/l nitrates (0,5 – 200,0) mg/l nitrate nitrogen (0,12 – 45,2) mg/l sulfates (10 – 4000) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
16 Water, wastewater Metal concentrations
arsenic (0,033 – 3,3) mg/l boron (0,05 – 8,3) mg/l cadmium (0,0033 – 0,83) mg/l chromium (0,007 – 1,67) mg/l copper (0,007 – 1,67) mg/l iron (0,10 – 16,6) mg/l potassium (0,33 – 83) mg/l manganese (0,033 – 8,3) mg/l molybdenum (0,0033 – 2,0) mg/l nickel (0,007 – 1,67) mg/l phosphorus (0,067 – 16,6) mg/l lead (0,01 – 1,67) mg/l tin (0,007 – 4,0) mg/l vanadium (0,007 – 4,0) mg/l zinc (0,007 – 4,0) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009

Reference standards (17)

IB/20/ZJO/ZJ wyd. 5 z dnia 02.01.2026 r.
P N - 8 2 / C - 0 4 5 7 6 - 0 8
P N - E N I S O 6878:2006 p. 7 +Ap1:2010+Ap2:2010
P N - I S O 9 2 8 0 : 2 0 0 2
P N - I S O 9 2 9 7 : 1 9 9 4
P N -74/C-04578.03
P N -EN 1899-2:2002
P N -EN ISO 5815-1:2019-12
P N -ISO 6060:2006
PN-77/C-04584
PN-78/C-04588.03
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6
PN-ISO 5667-10:2021-11