🇵🇱 CENTRALNY WODOCIĄG ŻUŁAWSKI Sp. z o.o. PL

PCA AB 925 • Nowy Dwór Gdański, Poland • 30 methods

Water & wastewaterMicrobiology

CENTRALNY WODOCIĄG ŻUŁAWSKI Sp. z o.o. is a laboratory accredited by PCA under number AB 925 (Nowy Dwór Gdański, Poland). Its accreditation scope covers 30 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Wastewater. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 925
  • Methods in scope: 30
  • Types of test objects: 2
  • Techniques used: 10
  • City: Nowy Dwór Gdański, Poland
Accreditation number
AB 925
Accreditation body
PCA
Address
W NOWYM DWORZE GDAŃSKIM, ul. Warszawska 28 A, 82-100 Nowy Dwór Gdański, LABORATORIUM BADANIA WODY I ŚCIEKÓW W ZĄBROWIE
City
Nowy Dwór Gdański, Poland

What this laboratory tests (2)

Analytical techniques used (10)

Accreditation scope — test methods (30)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Turbidity
Range (0,02 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
2 Water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Spectrophotometric method PB/Ch-07 wydanie 2 z dnia 30.04.2021 r.
3 Water intended for human consumption pH
Range 2,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
4 Water intended for human consumption Total iron concentration
Range (10 – 10000) μg/l
Spectrophotometric method PN-ISO 6332:2001+ Ap1:2016-06
5 Water intended for human consumption Ammonia concentration
Range (0,10 – 5,00) mg/l
Spectrophotometric method PB/Ch-10 wydanie 2 z dnia 30.04.2021 r. na podstawie testu Merck nr 1.14752.0001
6 Water intended for human consumption Nitrite concentration
Range (0,008 – 0,25) mg/l
Spectrophotometric method PN-EN 26777:1999
7 Water intended for human consumption Nitrate concentration
Range (0,07 – 50) mg/l
Spectrophotometric method PN-82/C-04576.08
8 Water intended for human consumption Manganese concentration
Range (5 – 2800) μg/l
Spectrophotometric method PB/Ch-01 wydanie 5 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange nr 8149
9 Water intended for human consumption Chloride concentration
Range (5,00 – 300) mg/l
Titrimetric method PN-ISO 9297:1994
10 Water intended for human consumption Electrical conductivity
Range 50 μS /cm – 3000 μS /cm
Conductometric method PN-EN 27888:1999
11 Water intended for human consumption Calcium concentration
Range (2,0 – 150) mg/l
Titrimetric method PN-ISO 6058:1999
12 Water intended for human consumption Total hardness
Range (5 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
13 Water intended for human consumption Fluoride concentration
Range (0,10 – 2,00) mg/l
Spectrophotometric method PB/Ch-09 wydanie 2 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange nr 8029
14 Water intended for human consumption Biochemical oxygen demand – BOD5
Range (1 – 6) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
15 Water intended for human consumption Chemical oxygen demand − COD-Cr
Range (5,00 – 50) mg/l O2
Spectrophotometric method P N - ISO 15705:2005
16 Water intended for human consumption Total suspended solids (TSS)
Range (2,0 – 50) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
17 Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11
18 Wastewater Chemical oxygen demand − COD-Cr
Range (5,00 – 2000) mg/l O2
Spectrophotometric method P N - ISO 15705:2005
19 Wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
20 Wastewater Biochemical oxygen demand – BOD5
Range (1 – 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
21 Wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
22 Wastewater Chloride concentration
Range (5,00 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
23 Wastewater Total iron concentration
Range (0,500 – 10) mg/l
Spectrophotometric method PN-ISO 6332:2001 + Ap1:2016-06
24 Wastewater Total nitrogen concentration
Range (5,00 – 100) mg/l
Spectrophotometric method PB/Ch-05 wydanie 2 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange LCK 238, 338
25 Wastewater Total phosphorus concentration
Range (0,050 – 40,0) mg/l
Spectrophotometric method PB/Ch-03 wydanie 3 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange LCK 348, 349, 350
26 Water intended for human consumption Sampling for physical and chemical testing PN-ISO 5667-5:2017-10
27 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
28 Water intended for human consumption Total count of microorganisms at 22 °C and 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
29 Water intended for human consumption Escherichia coli and coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04
30 Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004

Reference standards (30)

P N - ISO 15705:2005
PB/Ch-01 wydanie 5 z dnia 30.04.2021 r.
PB/Ch-03 wydanie 3 z dnia 30.04.2021 r.
PB/Ch-05 wydanie 2 z dnia 30.04.2021 r.
PB/Ch-07 wydanie 2 z dnia 30.04.2021 r.
PB/Ch-09 wydanie 2 z dnia 30.04.2021 r.
PB/Ch-10 wydanie 2 z dnia 30.04.2021 r. na podstawie testu Merck nr 1.14752.0001
PN-82/C-04576.08
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/ A1:2017-04
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001 + Ap1:2016-06
PN-ISO 6332:2001+ Ap1:2016-06
PN-ISO 9297:1994
na podstawie testu kuwetowego Hach Lange LCK 238, 338
na podstawie testu kuwetowego Hach Lange LCK 348, 349, 350
na podstawie testu kuwetowego Hach Lange nr 8029
na podstawie testu kuwetowego Hach Lange nr 8149