{"lab":{"_id":"69ad52a3de79e566650fb4a4","accr_number":"AB 925","country":"PL","accr_body":"PCA","address":"W NOWYM DWORZE GDAŃSKIM, ul. Warszawska 28 A, 82-100 Nowy Dwór Gdański, LABORATORIUM BADANIA WODY I ŚCIEKÓW W ZĄBROWIE","categories":["water","microbiology"],"city":"Nowy Dwór Gdański","imported_at":"2026-03-08T10:42:43.265Z","methods_count":30,"name":"CENTRALNY WODOCIĄG ŻUŁAWSKI Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_925.pdf"],"scope_summary":"","search_text":"centralny wodociąg żuławski sp. z o.o. w nowym dworze gdańskim, ul. warszawska 28 a, 82-100 nowy dwór gdański, laboratorium badania wody i ścieków w ząbrowie water other pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:51:49.057Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:49.057Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20925,podmiot.html","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties of drinking water, sewage"}],"issue":{"no":"19","date":"27.06.2024"},"parse_date":"2026-07-20T07:09:58.798Z","parse_source":"script-pdfplumber","map_coord":[54.206698,19.12218],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":30,"microbiology":2},"category_scores":{"water":28.13,"microbiology":0.13},"has_zh":true},"methods":[{"_id":"6a5dc9c6f1c10c8ce826069c","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,02 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,02 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,02 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,02 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,02 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,02 – 100) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce826069d","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PB/Ch-07 wydanie 2 z dnia 30.04.2021 r.","norm_bases":["PB/Ch-07 wydanie 2 z dnia 30.04.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna PB/Ch-07 wydanie 2 z dnia 30.04.2021 r. Woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna PB/Ch-07 wydanie 2 z dnia 30.04.2021 r.","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Colour Spectrophotometric method Range PB/Ch-07 wydanie 2 z dnia 30.04.2021 r.","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PB/Ch-07 wydanie 2 z dnia 30.04.2021 r.","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce826069e","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce826069f","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(10 – 10000) μg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 10000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (10 – 10000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+ Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+ Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (10 – 10000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+ Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (10 – 10000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+ Ap1:2016-06","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+ Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(10 – 10000) μg/l"}],"search_zh":"生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+ Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce82606a0","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie amoniaku","methodology_en":"Ammonia concentration","parameters":[{"name":"Zakres","range":"(0,10 – 5,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie amoniaku\nZakres (0,10 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PB/Ch-10 wydanie 2 z dnia 30.04.2021 r. na podstawie testu Merck nr 1.14752.0001","norm_bases":["PB/Ch-10 wydanie 2 z dnia 30.04.2021 r. na podstawie testu Merck nr 1.14752.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie amoniaku\nZakres (0,10 – 5,00) mg/l\nMetoda spektrofotometryczna PB/Ch-10 wydanie 2 z dnia 30.04.2021 r. na podstawie testu Merck nr 1.14752.0001 Woda do spozycia przez ludzi Stezenie amoniaku\nZakres (0,10 – 5,00) mg/l\nMetoda spektrofotometryczna PB/Ch-10 wydanie 2 z dnia 30.04.2021 r. na podstawie testu Merck nr 1.14752.0001","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Ammonia concentration Spectrophotometric method Range PB/Ch-10 wydanie 2 z dnia 30.04.2021 r. na podstawie testu Merck nr 1.14752.0001","parameters_zh":[{"name":"范围","range":"(0,10 – 5,00) mg/l"}],"search_zh":"生活饮用水 氨浓度 分光光度法 范围 PB/Ch-10 wydanie 2 z dnia 30.04.2021 r. na podstawie testu Merck nr 1.14752.0001","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"氨浓度"},{"_id":"6a5dc9c6f1c10c8ce82606a1","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,008 – 0,25) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,008 – 0,25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,008 – 0,25) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,008 – 0,25) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,008 – 0,25) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,008 – 0,25) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce82606a2","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,07 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,07 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,07 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,07 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,07 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,07 – 50) mg/l"}],"search_zh":"生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce82606a3","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(5 – 2800) μg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 2800) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (5 – 2800) μg/l\nMetoda spektrofotometryczna","reference":"PB/Ch-01 wydanie 5 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange nr 8149","norm_bases":["PB/Ch-01 wydanie 5 z dnia 30.04.2021 r.","na podstawie testu kuwetowego Hach Lange nr 8149"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (5 – 2800) μg/l\nMetoda spektrofotometryczna PB/Ch-01 wydanie 5 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange nr 8149 Woda do spozycia przez ludzi Stezenie manganu\nZakres (5 – 2800) μg/l\nMetoda spektrofotometryczna PB/Ch-01 wydanie 5 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange nr 8149","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Range PB/Ch-01 wydanie 5 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange nr 8149","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(5 – 2800) μg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 范围 PB/Ch-01 wydanie 5 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange nr 8149","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce82606a4","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,00 – 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,00 – 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,00 – 300) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,00 – 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,00 – 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 300) mg/l"}],"search_zh":"生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce82606a5","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"50 μS /cm – 3000 μS /cm"}],"parameters_en":[{"name":"Range","range":"50 μS /cm – 3000 μS /cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres 50 μS /cm – 3000 μS /cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres 50 μS /cm – 3000 μS /cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres 50 μS /cm – 3000 μS /cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"50 μS /cm – 3000 μS /cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce82606a6","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(2,0 – 150) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (2,0 – 150) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie wapnia\nZakres (2,0 – 150) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda do spozycia przez ludzi Stezenie wapnia\nZakres (2,0 – 150) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(2,0 – 150) mg/l"}],"search_zh":"生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a5dc9c6f1c10c8ce82606a7","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Twardość ogólna","methodology_en":"Total hardness","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(5 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Twardość ogólna\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Twardość ogólna\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Twardosc ogolna\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total hardness Titrimetric method Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(5 – 500) mg/l CaCO3"}],"search_zh":"生活饮用水 总硬度 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水","methodology_zh":"总硬度"},{"_id":"6a5dc9c6f1c10c8ce82606a8","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie fluorków","methodology_en":"Fluoride concentration","parameters":[{"name":"Zakres","range":"(0,10 – 2,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fluorków\nZakres (0,10 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PB/Ch-09 wydanie 2 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange nr 8029","norm_bases":["PB/Ch-09 wydanie 2 z dnia 30.04.2021 r.","na podstawie testu kuwetowego Hach Lange nr 8029"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie fluorków\nZakres (0,10 – 2,00) mg/l\nMetoda spektrofotometryczna PB/Ch-09 wydanie 2 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange nr 8029 Woda do spozycia przez ludzi Stezenie fluorkow\nZakres (0,10 – 2,00) mg/l\nMetoda spektrofotometryczna PB/Ch-09 wydanie 2 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange nr 8029","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Fluoride concentration Spectrophotometric method Range PB/Ch-09 wydanie 2 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange nr 8029","parameters_zh":[{"name":"范围","range":"(0,10 – 2,00) mg/l"}],"search_zh":"生活饮用水 氟化物浓度 分光光度法 范围 PB/Ch-09 wydanie 2 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange nr 8029","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"氟化物浓度"},{"_id":"6a5dc9c6f1c10c8ce82606a9","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(1 – 6) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1 – 6) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 6) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 6) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda do spozycia przez ludzi Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 6) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Biochemical oxygen demand – BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(1 – 6) mg/l O2"}],"search_zh":"生活饮用水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"生活饮用水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c6f1c10c8ce82606aa","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","methodology_en":"Chemical oxygen demand − COD-Cr","parameters":[{"name":"Zakres","range":"(5,00 – 50) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(5,00 – 50) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (5,00 – 50) mg/l O2\nMetoda spektrofotometryczna","reference":"P N - ISO 15705:2005","norm_bases":["P N - ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (5,00 – 50) mg/l O2\nMetoda spektrofotometryczna P N - ISO 15705:2005 Woda do spozycia przez ludzi Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (5,00 – 50) mg/l O2\nMetoda spektrofotometryczna P N - ISO 15705:2005","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Chemical oxygen demand − COD-Cr Spectrophotometric method Range P N - ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(5,00 – 50) mg/l O2"}],"search_zh":"生活饮用水 化学需氧量 － COD-Cr 分光光度法 范围 P N - ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a5dc9c6f1c10c8ce82606ab","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 50) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 50) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Zawiesiny ogólne\nZakres (2,0 – 50) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda do spozycia przez ludzi Zawiesiny ogolne\nZakres (2,0 – 50) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 50) mg/l"}],"search_zh":"生活饮用水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce82606ac","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"technique_en":"Manual and automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工与自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a5dc9c6f1c10c8ce82606ad","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","methodology_en":"Chemical oxygen demand − COD-Cr","parameters":[{"name":"Zakres","range":"(5,00 – 2000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(5,00 – 2000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (5,00 – 2000) mg/l O2\nMetoda spektrofotometryczna","reference":"P N - ISO 15705:2005","norm_bases":["P N - ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (5,00 – 2000) mg/l O2\nMetoda spektrofotometryczna P N - ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (5,00 – 2000) mg/l O2\nMetoda spektrofotometryczna P N - ISO 15705:2005","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand − COD-Cr Spectrophotometric method Range P N - ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(5,00 – 2000) mg/l O2"}],"search_zh":"污水 化学需氧量 － COD-Cr 分光光度法 范围 P N - ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a5dc9c6f1c10c8ce82606ae","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9c6f1c10c8ce82606af","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand – BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c6f1c10c8ce82606b0","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a5dc9c6f1c10c8ce82606b1","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,00 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,00 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 1000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9c6f1c10c8ce82606b2","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,500 – 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,500 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,500 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 + Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 + Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (0,500 – 10) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06 Scieki Stezenie zelaza ogolnego\nZakres (0,500 – 10) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 + Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,500 – 10) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 + Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c6f1c10c8ce82606b3","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(5,00 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,00 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (5,00 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PB/Ch-05 wydanie 2 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange LCK 238, 338","norm_bases":["PB/Ch-05 wydanie 2 z dnia 30.04.2021 r.","na podstawie testu kuwetowego Hach Lange LCK 238, 338"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (5,00 – 100) mg/l\nMetoda spektrofotometryczna PB/Ch-05 wydanie 2 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange LCK 238, 338 Scieki Stezenie azotu ogolnego\nZakres (5,00 – 100) mg/l\nMetoda spektrofotometryczna PB/Ch-05 wydanie 2 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange LCK 238, 338","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Range PB/Ch-05 wydanie 2 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange LCK 238, 338","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 100) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 范围 PB/Ch-05 wydanie 2 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange LCK 238, 338","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c6f1c10c8ce82606b4","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,050 – 40,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/Ch-03 wydanie 3 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange LCK 348, 349, 350","norm_bases":["PB/Ch-03 wydanie 3 z dnia 30.04.2021 r.","na podstawie testu kuwetowego Hach Lange LCK 348, 349, 350"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,050 – 40,0) mg/l\nMetoda spektrofotometryczna PB/Ch-03 wydanie 3 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange LCK 348, 349, 350 Scieki Stezenie fosforu ogolnego\nZakres (0,050 – 40,0) mg/l\nMetoda spektrofotometryczna PB/Ch-03 wydanie 3 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange LCK 348, 349, 350","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PB/Ch-03 wydanie 3 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange LCK 348, 349, 350","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 40,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PB/Ch-03 wydanie 3 z dnia 30.04.2021 r. | na podstawie testu kuwetowego Hach Lange LCK 348, 349, 350","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c6f1c10c8ce82606b5","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","methodology_en":"Sampling for physical and chemical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań fizycznych i chemicznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan fizycznych i chemicznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for physical and chemical testing PN-ISO 5667-5:2017-10","methodology_zh":"物理与化学检测用样品采集","search_zh":"生活饮用水 物理与化学检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce82606b6","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce82606b7","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22 °C i 36 °C","methodology_en":"Total count of microorganisms at 22 °C and 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C i 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C i 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C i 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total count of microorganisms at 22 °C and 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c6f1c10c8ce82606b8","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba Escherichia coli i bakterii grupy coli","methodology_en":"Escherichia coli and coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli i bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/ A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli i bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli i bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","categories":["microbiology","water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Escherichia coli and coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","search_zh":"生活饮用水 大肠埃希氏菌与大肠菌群数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"大肠埃希氏菌与大肠菌群数"},{"_id":"6a5dc9c6f1c10c8ce82606b9","lab_id":"69ad52a3de79e566650fb4a4","country":"PL","accr_number":"AB 925","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba enterokoków","methodology_en":"Enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"肠球菌计数","search_zh":"生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"}],"has_pdf":true}