🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 920 • Ełk, Poland • 60 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 920 (Ełk, Poland). Its accreditation scope covers 60 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Wastewater, Wastewater, water intended for human consumption, water, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.

At a glance

  • Accreditation number: PCA AB 920
  • Methods in scope: 60
  • Types of test objects: 4
  • Techniques used: 10
  • City: Ełk, Poland
Accreditation number
AB 920
Accreditation body
PCA
Address
ul. Suwalska 64, 19-300 Ełk, LABORATORIUM WODY I ŚCIEKÓW, ul. Ełcka 30
City
Ełk, Poland

What this laboratory tests (4)

Analytical techniques used (10)

Accreditation scope — test methods (60)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Wastewater Ammonium nitrogen concentration
Range (1,0 − 1000) mg/l Range (1,29 – 1290) mg/l NH4+
Titrimetric method PN-ISO 5664:2002
2 Wastewater Kjeldahl nitrogen concentration
Range (5,00 − 1000) mg/l
Titrimetric method PB-02 wydanie III z dnia 25.11.2015 r.
3 Wastewater Nitrate nitrogen concentration
Range (0,20 – 50,0) mg/l Range (0,89 – 221) mg/l NO3 -
Spectrophotometric method PN-82/C-04576/08
4 Wastewater Total phosphorus concentration
Range (0,07 − 48,9) mg/l
Spectrophotometric method PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26
5 Wastewater Biochemical oxygen demand
BOD5 Range (3,0 − 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
6 Wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
7 Wastewater Total suspended solids (TSS)
Range (2,0 − 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
8 Wastewater Total nitrogen concentration
Range (1,0 − 1000) mg/l
Spectrophotometric method PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.
9 Wastewater Total nitrogen content (calculated) PB-10 wydanie III z dnia 16.03.2023 r.
10 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
11 Wastewater, water intended for human consumption, water Ammonium nitrogen concentration
Range (0,05 − 2,0) mg/l Range (0,064 – 2,60) mg/l NH4+
Spectrophotometric method PN-ISO 7150-1:2002
12 Wastewater, water intended for human consumption, water Chloride concentration
Range (5,00 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
13 Wastewater, water intended for human consumption, water Chemical oxygen demand
COD Range (10,0 – 20 000) mg/l O2
Spectrophotometric method P N-ISO15705:2005
14 Wastewater, water intended for human consumption, water Sulfate concentration
Range (20,0 – 250) mg/l
Spectrophotometric method PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99
15 Wastewater, water intended for human consumption, water pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
16 Wastewater, water intended for human consumption, water Nitrite nitrogen concentration
Range (0,020 – 4,0) mg/l Range (0,066 – 13,2) mg/l NO2 -
Spectrophotometric method PN-EN 26777:1999
17 Water intended for human consumption Sampling for physical and chemical testing PN-ISO 5667-5:2017-10
18 Water, water intended for human consumption Iron concentration
Range (20 – 4000) μg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
19 Water, water intended for human consumption Manganese concentration
Range (15 – 4000) μg/l
Spectrophotometric method PN-92/C-04590.03
20 Water, water intended for human consumption Nitrate nitrogen concentration
Range (0,20 – 50,0) mg/l Range (0,89 – 221) mg/l NO3 -
Spectrophotometric method PN-82/C-04576/08
21 Water, water intended for human consumption Electrical conductivity
Range (10 – 3900) μS/cm
Conductometric method PN-EN 27888:1999
22 Water, water intended for human consumption Colour
Range (3 – 125) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
23 Water, water intended for human consumption Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
24 Water, water intended for human consumption Total hardness
Range (5,00 – 600) mg/l CaCO3 Range (0,28 – 33,7) °DH
Titrimetric method PN-ISO 6059:1999
25 Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6
26 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
27 Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
28 Water, water intended for human consumption Count of enterococci bacteria Membrane filtration method PN-EN ISO 7899-2:2004
29 Water, water intended for human consumption Total viable count at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004 Scope of accreditation No. AB 920
30 Water, water intended for human consumption Total viable count at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004 Scope of accreditation No. AB 920
31 Wastewater Ammonium nitrogen concentration
Range (1,0 − 1000) mg/l Range (1,29 – 1290) mg/l NH4+
Titrimetric method PN-ISO 5664:2002
32 Wastewater Kjeldahl nitrogen concentration
Range (5,00 − 1000) mg/l
Titrimetric method PB-02 wydanie III z dnia 25.11.2015 r.
33 Wastewater Nitrate nitrogen concentration
Range (0,20 – 50,0) mg/l Range (0,89 – 221) mg/l NO3 -
Spectrophotometric method PN-82/C-04576/08
34 Wastewater Total phosphorus concentration
Range (0,07 − 48,9) mg/l
Spectrophotometric method PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26
35 Wastewater Biochemical oxygen demand
BOD5 Range (3,0 − 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
36 Wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
37 Wastewater Total suspended solids (TSS)
Range (2,0 − 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
38 Wastewater Total nitrogen concentration
Range (1,0 − 1000) mg/l
Spectrophotometric method PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.
39 Wastewater Total nitrogen content (calculated) PB-10 wydanie III z dnia 16.03.2023 r.
40 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
41 Wastewater, water intended for human consumption, water Ammonium nitrogen concentration
Range (0,05 − 2,0) mg/l Range (0,064 – 2,60) mg/l NH4+
Spectrophotometric method PN-ISO 7150-1:2002
42 Wastewater, water intended for human consumption, water Chloride concentration
Range (5,00 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
43 Wastewater, water intended for human consumption, water Chemical oxygen demand
COD Range (10,0 – 20 000) mg/l O2
Spectrophotometric method P N-ISO15705:2005
44 Wastewater, water intended for human consumption, water Sulfate concentration
Range (20,0 – 250) mg/l
Spectrophotometric method PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99
45 Wastewater, water intended for human consumption, water pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
46 Wastewater, water intended for human consumption, water Nitrite nitrogen concentration
Range (0,020 – 4,0) mg/l Range (0,066 – 13,2) mg/l NO2 -
Spectrophotometric method PN-EN 26777:1999
47 Water intended for human consumption Sampling for physical and chemical testing PN-ISO 5667-5:2017-10
48 Water, water intended for human consumption Iron concentration
Range (20 – 4000) μg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
49 Water, water intended for human consumption Manganese concentration
Range (15 – 4000) μg/l
Spectrophotometric method PN-92/C-04590.03
50 Water, water intended for human consumption Nitrate nitrogen concentration
Range (0,20 – 50,0) mg/l Range (0,89 – 221) mg/l NO3 -
Spectrophotometric method PN-82/C-04576/08
51 Water, water intended for human consumption Electrical conductivity
Range (10 – 3900) μS/cm
Conductometric method PN-EN 27888:1999
52 Water, water intended for human consumption Colour
Range (3 – 125) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
53 Water, water intended for human consumption Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
54 Water, water intended for human consumption Total hardness
Range (5,00 – 600) mg/l CaCO3 Range (0,28 – 33,7) °DH
Titrimetric method PN-ISO 6059:1999
55 Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6
56 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
57 Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
58 Water, water intended for human consumption Count of enterococci bacteria Membrane filtration method PN-EN ISO 7899-2:2004
59 Water, water intended for human consumption Total viable count at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004
60 Water, water intended for human consumption Total viable count at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004

Reference standards (31)

P N-ISO15705:2005
PB-02 wydanie III z dnia 25.11.2015 r.
PB-03 wydanie III z dnia 25.11.2015 r.
PB-07 wydanie I z dnia 04.09.2023 r.
PB-08 wydanie II z dnia 25.11 2015 r.
PB-10 wydanie III z dnia 16.03.2023 r.
PN-82/C-04576/08
PN-92/C-04590.03
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6222:2004 Scope of accreditation No. AB 920
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994
na podstawie testu Hach nr 12065-99
na podstawie testu kuwetowego Hach-Lange nr 26
na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.