{"lab":{"_id":"69ad52a3de79e566650fb49e","accr_number":"AB 920","country":"PL","accr_body":"PCA","address":"ul. Suwalska 64, 19-300 Ełk, LABORATORIUM WODY I ŚCIEKÓW, ul. Ełcka 30","categories":["water","microbiology"],"city":"Ełk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":60,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_920.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji sp. z o.o. ul. suwalska 64, 19-300 ełk, laboratorium wody i ścieków, ul. ełcka 30 water other pharma electronics microbiology","status":"active","updated_at":"2026-03-08T14:51:48.761Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:48.761Z","email_confidence":"high","email_mx":true,"email_source":"https://pwikelk.pl/kontakt/","fields_of_testing":[{"codes":"C/28/P, C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"K/28/P, K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/28/P, N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water , drinking water, sewage"}],"issue":{"no":"16","date":"05.06.2024"},"parse_date":"2026-07-20T07:09:54.513Z","parse_source":"script-pdfplumber","map_coord":[53.830946,22.381317],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":60,"microbiology":8},"category_scores":{"water":52.94,"microbiology":0.94},"has_zh":true},"methods":[{"_id":"6a5dc9c2f1c10c8ce825f9b5","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 − 1000) mg/l"},{"name":"Zakres","range":"(1,29 – 1290) mg/l NH4+"}],"parameters_en":[{"name":"Range","range":"(1,0 − 1000) mg/l"},{"name":"Range","range":"(1,29 – 1290) mg/l NH4+"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (1,0 − 1000) mg/l\nZakres (1,29 – 1290) mg/l NH4+\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres:\nZakres (1,0 − 1000) mg/l\nZakres (1,29 – 1290) mg/l NH4+\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres:\nZakres (1,0 − 1000) mg/l\nZakres (1,29 – 1290) mg/l NH4+\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 − 1000) mg/l"},{"name":"范围","range":"(1,29 – 1290) mg/l NH4+"}],"search_zh":"污水 氨氮浓度 滴定法 范围 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9b6","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(5,00 − 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,00 − 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (5,00 − 1000) mg/l\nMetoda miareczkowa","reference":"PB-02 wydanie III z dnia 25.11.2015 r.","norm_bases":["PB-02 wydanie III z dnia 25.11.2015 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (5,00 − 1000) mg/l\nMetoda miareczkowa PB-02 wydanie III z dnia 25.11.2015 r. Scieki Stezenie azotu Kjeldahla\nZakres (5,00 − 1000) mg/l\nMetoda miareczkowa PB-02 wydanie III z dnia 25.11.2015 r.","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PB-02 wydanie III z dnia 25.11.2015 r.","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(5,00 − 1000) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PB-02 wydanie III z dnia 25.11.2015 r.","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9b7","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,20 – 50,0) mg/l"},{"name":"Zakres","range":"(0,89 – 221) mg/l NO3 -"}],"parameters_en":[{"name":"Range","range":"(0,20 – 50,0) mg/l"},{"name":"Range","range":"(0,89 – 221) mg/l NO3 -"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 50,0) mg/l"},{"name":"范围","range":"(0,89 – 221) mg/l NO3 -"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9b8","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,07 − 48,9) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,07 − 48,9) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,07 − 48,9) mg/l\nMetoda spektrofotometryczna","reference":"PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26","norm_bases":["PB-03 wydanie III z dnia 25.11.2015 r.","na podstawie testu kuwetowego Hach-Lange nr 26"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,07 − 48,9) mg/l\nMetoda spektrofotometryczna PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26 Scieki Stezenie fosforu ogolnego\nZakres (0,07 − 48,9) mg/l\nMetoda spektrofotometryczna PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,07 − 48,9) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9b9","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3,0 − 6000) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3,0 − 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 − 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 − 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 − 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3,0 − 6000) mg/l O2"}],"search_zh":"污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9ba","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 – 6,0) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 – 6,0) mg/l O2"}],"search_zh":"污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9bb","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 − 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 − 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 − 2000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9bc","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 − 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 − 1000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 − 1000) mg/l\nMetoda spektrofotometryczna","reference":"PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.","norm_bases":["PB-07 wydanie I z dnia 04.09.2023 r.","na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1,0 − 1000) mg/l\nMetoda spektrofotometryczna PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338. Scieki Stezenie azotu ogolnego\nZakres (1,0 − 1000) mg/l\nMetoda spektrofotometryczna PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Range PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 − 1000) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 范围 PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9bd","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawartość azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu ogólnego (z obliczeń)","reference":"PB-10 wydanie III z dnia 16.03.2023 r.","norm_bases":["PB-10 wydanie III z dnia 16.03.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawartość azotu ogólnego (z obliczeń) PB-10 wydanie III z dnia 16.03.2023 r. Scieki Zawartosc azotu ogolnego (z obliczen) PB-10 wydanie III z dnia 16.03.2023 r.","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen content (calculated) PB-10 wydanie III z dnia 16.03.2023 r.","search_zh":"污水 PB-10 wydanie III z dnia 16.03.2023 r.","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9be","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9bf","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi, woda","test_object_en":"Wastewater, water intended for human consumption, water","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 − 2,0) mg/l"},{"name":"Zakres","range":"(0,064 – 2,60) mg/l NH4+"}],"parameters_en":[{"name":"Range","range":"(0,05 − 2,0) mg/l"},{"name":"Range","range":"(0,064 – 2,60) mg/l NH4+"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,05 − 2,0) mg/l\nZakres (0,064 – 2,60) mg/l NH4+\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda do spożycia przez ludzi, woda Stężenie azotu amonowego\nZakres:\nZakres (0,05 − 2,0) mg/l\nZakres (0,064 – 2,60) mg/l NH4+\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki, woda do spozycia przez ludzi, woda Stezenie azotu amonowego\nZakres:\nZakres (0,05 − 2,0) mg/l\nZakres (0,064 – 2,60) mg/l NH4+\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water intended for human consumption, water Ammonium nitrogen concentration Spectrophotometric method Range Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 − 2,0) mg/l"},{"name":"范围","range":"(0,064 – 2,60) mg/l NH4+"}],"search_zh":"废水、生活饮用水、水 氨氮浓度 分光光度法 范围 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"废水、生活饮用水、水"},{"_id":"6a5dc9c2f1c10c8ce825f9c0","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi, woda","test_object_en":"Wastewater, water intended for human consumption, water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,00 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,00 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda do spożycia przez ludzi, woda Stężenie chlorków\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, woda do spozycia przez ludzi, woda Stezenie chlorkow\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water intended for human consumption, water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 1000) mg/l"}],"search_zh":"废水、生活饮用水、水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"废水、生活饮用水、水"},{"_id":"6a5dc9c2f1c10c8ce825f9c1","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi, woda","test_object_en":"Wastewater, water intended for human consumption, water","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT"},{"name":"Zakres","range":"(10,0 – 20 000) mg/l O2"}],"parameters_en":[{"name":"COD"},{"name":"Range","range":"(10,0 – 20 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (10,0 – 20 000) mg/l O2\nMetoda spektrofotometryczna","reference":"P N-ISO15705:2005","norm_bases":["P N-ISO15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda do spożycia przez ludzi, woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (10,0 – 20 000) mg/l O2\nMetoda spektrofotometryczna P N-ISO15705:2005 Scieki, woda do spozycia przez ludzi, woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (10,0 – 20 000) mg/l O2\nMetoda spektrofotometryczna P N-ISO15705:2005","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water intended for human consumption, water Chemical oxygen demand Spectrophotometric method COD Range P N-ISO15705:2005","parameters_zh":[{"name":"化学需氧量（COD）"},{"name":"范围","range":"(10,0 – 20 000) mg/l O2"}],"search_zh":"废水、生活饮用水、水 化学需氧量（COD） 分光光度法 化学需氧量（COD） 范围 P N-ISO15705:2005","technique_zh":"分光光度法","methodology_zh":"化学需氧量（COD）","test_object_zh":"废水、生活饮用水、水"},{"_id":"6a5dc9c2f1c10c8ce825f9c2","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi, woda","test_object_en":"Wastewater, water intended for human consumption, water","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(20,0 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(20,0 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (20,0 – 250) mg/l\nMetoda spektrofotometryczna","reference":"PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99","norm_bases":["PB-08 wydanie II z dnia 25.11 2015 r.","na podstawie testu Hach nr 12065-99"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda do spożycia przez ludzi, woda Stężenie siarczanów\nZakres (20,0 – 250) mg/l\nMetoda spektrofotometryczna PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99 Scieki, woda do spozycia przez ludzi, woda Stezenie siarczanow\nZakres (20,0 – 250) mg/l\nMetoda spektrofotometryczna PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water intended for human consumption, water Sulfate concentration Spectrophotometric method Range PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(20,0 – 250) mg/l"}],"search_zh":"废水、生活饮用水、水 硫酸盐浓度 分光光度法 范围 PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99","technique_zh":"分光光度法","test_object_zh":"废水、生活饮用水、水"},{"_id":"6a5dc9c2f1c10c8ce825f9c3","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi, woda","test_object_en":"Wastewater, water intended for human consumption, water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda do spożycia przez ludzi, woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, woda do spozycia przez ludzi, woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water intended for human consumption, water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"废水、生活饮用水、水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、生活饮用水、水"},{"_id":"6a5dc9c2f1c10c8ce825f9c4","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi, woda","test_object_en":"Wastewater, water intended for human consumption, water","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,020 – 4,0) mg/l"},{"name":"Zakres","range":"(0,066 – 13,2) mg/l NO2 -"}],"parameters_en":[{"name":"Range","range":"(0,020 – 4,0) mg/l"},{"name":"Range","range":"(0,066 – 13,2) mg/l NO2 -"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nZakres (0,066 – 13,2) mg/l NO2 -\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda do spożycia przez ludzi, woda Stężenie azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nZakres (0,066 – 13,2) mg/l NO2 -\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki, woda do spozycia przez ludzi, woda Stezenie azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nZakres (0,066 – 13,2) mg/l NO2 -\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water intended for human consumption, water Nitrite nitrogen concentration Spectrophotometric method Range Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 4,0) mg/l"},{"name":"范围","range":"(0,066 – 13,2) mg/l NO2 -"}],"search_zh":"废水、生活饮用水、水 亚硝态氮浓度 分光光度法 范围 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"废水、生活饮用水、水"},{"_id":"6a5dc9c2f1c10c8ce825f9c5","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","methodology_en":"Sampling for physical and chemical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań fizycznych i chemicznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan fizycznych i chemicznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for physical and chemical testing PN-ISO 5667-5:2017-10","methodology_zh":"物理与化学检测用样品采集","search_zh":"生活饮用水 物理与化学检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9c6","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(20 – 4000) μg/l"}],"parameters_en":[{"name":"Range","range":"(20 – 4000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (20 – 4000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza\nZakres (20 – 4000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza\nZakres (20 – 4000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20 – 4000) μg/l"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9c7","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(15 – 4000) μg/l"}],"parameters_en":[{"name":"Range","range":"(15 – 4000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (15 – 4000) μg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590.03","norm_bases":["PN-92/C-04590.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (15 – 4000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590.03 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (15 – 4000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590.03","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590.03","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 4000) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590.03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9c8","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,20 – 50,0) mg/l"},{"name":"Zakres","range":"(0,89 – 221) mg/l NO3 -"}],"parameters_en":[{"name":"Range","range":"(0,20 – 50,0) mg/l"},{"name":"Range","range":"(0,89 – 221) mg/l NO3 -"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, woda do spozycia przez ludzi Stezenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Nitrate nitrogen concentration Spectrophotometric method Range Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 50,0) mg/l"},{"name":"范围","range":"(0,89 – 221) mg/l NO3 -"}],"search_zh":"水、生活饮用水 硝态氮浓度 分光光度法 范围 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9c9","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(10 – 3900) μS/cm"}],"parameters_en":[{"name":"Range","range":"(10 – 3900) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 3900) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (10 – 3900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (10 – 3900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 3900) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9ca","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(3 – 125) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(3 – 125) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (3 – 125) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (3 – 125) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 Woda, woda do spozycia przez ludzi Barwa\nZakres (3 – 125) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(3 – 125) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9cb","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9cc","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Twardość ogólna","methodology_en":"Total hardness","parameters":[{"name":"Zakres","range":"(5,00 – 600) mg/l CaCO3"},{"name":"Zakres","range":"(0,28 – 33,7) °DH"}],"parameters_en":[{"name":"Range","range":"(5,00 – 600) mg/l CaCO3"},{"name":"Range","range":"(0,28 – 33,7) °DH"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Twardość ogólna\nZakres:\nZakres (5,00 – 600) mg/l CaCO3\nZakres (0,28 – 33,7) °DH\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Twardość ogólna\nZakres:\nZakres (5,00 – 600) mg/l CaCO3\nZakres (0,28 – 33,7) °DH\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Twardosc ogolna\nZakres:\nZakres (5,00 – 600) mg/l CaCO3\nZakres (0,28 – 33,7) °DH\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total hardness Titrimetric method Range Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(5,00 – 600) mg/l CaCO3"},{"name":"范围","range":"(0,28 – 33,7) °DH"}],"search_zh":"水、生活饮用水 总硬度 滴定法 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"总硬度"},{"_id":"6a5dc9c2f1c10c8ce825f9cd","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9ce","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9cf","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9d0","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii enterokoków","methodology_en":"Count of enterococci bacteria","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba bakterii enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water","microbiology"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Count of enterococci bacteria Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水、生活饮用水 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9d1","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 36 oC","methodology_en":"Total viable count at 36 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004 Scope of accreditation No. AB 920","norm_bases":["PN-EN ISO 6222:2004 Scope of accreditation No. AB 920"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Scope of accreditation No. AB 920 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004 Scope of accreditation No. AB 920","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total viable count at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004 Scope of accreditation No. AB 920","methodology_zh":"36 °C 微生物总数","search_zh":"水、生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004 Scope of accreditation No. AB 920","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9d2","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22 oC","methodology_en":"Total viable count at 22 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004 Scope of accreditation No. AB 920","norm_bases":["PN-EN ISO 6222:2004 Scope of accreditation No. AB 920"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Scope of accreditation No. AB 920 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004 Scope of accreditation No. AB 920","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total viable count at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004 Scope of accreditation No. AB 920","methodology_zh":"22 °C 微生物总数","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004 Scope of accreditation No. AB 920","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9d3","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 − 1000) mg/l"},{"name":"Zakres","range":"(1,29 – 1290) mg/l NH4+"}],"parameters_en":[{"name":"Range","range":"(1,0 − 1000) mg/l"},{"name":"Range","range":"(1,29 – 1290) mg/l NH4+"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (1,0 − 1000) mg/l\nZakres (1,29 – 1290) mg/l NH4+\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres:\nZakres (1,0 − 1000) mg/l\nZakres (1,29 – 1290) mg/l NH4+\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres:\nZakres (1,0 − 1000) mg/l\nZakres (1,29 – 1290) mg/l NH4+\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 − 1000) mg/l"},{"name":"范围","range":"(1,29 – 1290) mg/l NH4+"}],"search_zh":"污水 氨氮浓度 滴定法 范围 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9d4","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(5,00 − 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,00 − 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (5,00 − 1000) mg/l\nMetoda miareczkowa","reference":"PB-02 wydanie III z dnia 25.11.2015 r.","norm_bases":["PB-02 wydanie III z dnia 25.11.2015 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (5,00 − 1000) mg/l\nMetoda miareczkowa PB-02 wydanie III z dnia 25.11.2015 r. Scieki Stezenie azotu Kjeldahla\nZakres (5,00 − 1000) mg/l\nMetoda miareczkowa PB-02 wydanie III z dnia 25.11.2015 r.","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PB-02 wydanie III z dnia 25.11.2015 r.","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(5,00 − 1000) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PB-02 wydanie III z dnia 25.11.2015 r.","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9d5","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,20 – 50,0) mg/l"},{"name":"Zakres","range":"(0,89 – 221) mg/l NO3 -"}],"parameters_en":[{"name":"Range","range":"(0,20 – 50,0) mg/l"},{"name":"Range","range":"(0,89 – 221) mg/l NO3 -"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 50,0) mg/l"},{"name":"范围","range":"(0,89 – 221) mg/l NO3 -"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9d6","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,07 − 48,9) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,07 − 48,9) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,07 − 48,9) mg/l\nMetoda spektrofotometryczna","reference":"PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26","norm_bases":["PB-03 wydanie III z dnia 25.11.2015 r.","na podstawie testu kuwetowego Hach-Lange nr 26"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,07 − 48,9) mg/l\nMetoda spektrofotometryczna PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26 Scieki Stezenie fosforu ogolnego\nZakres (0,07 − 48,9) mg/l\nMetoda spektrofotometryczna PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,07 − 48,9) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9d7","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3,0 − 6000) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3,0 − 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 − 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 − 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 − 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3,0 − 6000) mg/l O2"}],"search_zh":"污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9d8","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 – 6,0) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 – 6,0) mg/l O2"}],"search_zh":"污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9d9","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 − 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 − 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 − 2000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9da","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 − 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 − 1000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 − 1000) mg/l\nMetoda spektrofotometryczna","reference":"PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.","norm_bases":["PB-07 wydanie I z dnia 04.09.2023 r.","na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1,0 − 1000) mg/l\nMetoda spektrofotometryczna PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338. Scieki Stezenie azotu ogolnego\nZakres (1,0 − 1000) mg/l\nMetoda spektrofotometryczna PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Range PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 − 1000) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 范围 PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9db","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawartość azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu ogólnego (z obliczeń)","reference":"PB-10 wydanie III z dnia 16.03.2023 r.","norm_bases":["PB-10 wydanie III z dnia 16.03.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawartość azotu ogólnego (z obliczeń) PB-10 wydanie III z dnia 16.03.2023 r. Scieki Zawartosc azotu ogolnego (z obliczen) PB-10 wydanie III z dnia 16.03.2023 r.","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen content (calculated) PB-10 wydanie III z dnia 16.03.2023 r.","search_zh":"污水 PB-10 wydanie III z dnia 16.03.2023 r.","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9dc","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f9dd","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi, woda","test_object_en":"Wastewater, water intended for human consumption, water","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 − 2,0) mg/l"},{"name":"Zakres","range":"(0,064 – 2,60) mg/l NH4+"}],"parameters_en":[{"name":"Range","range":"(0,05 − 2,0) mg/l"},{"name":"Range","range":"(0,064 – 2,60) mg/l NH4+"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,05 − 2,0) mg/l\nZakres (0,064 – 2,60) mg/l NH4+\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda do spożycia przez ludzi, woda Stężenie azotu amonowego\nZakres:\nZakres (0,05 − 2,0) mg/l\nZakres (0,064 – 2,60) mg/l NH4+\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki, woda do spozycia przez ludzi, woda Stezenie azotu amonowego\nZakres:\nZakres (0,05 − 2,0) mg/l\nZakres (0,064 – 2,60) mg/l NH4+\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water intended for human consumption, water Ammonium nitrogen concentration Spectrophotometric method Range Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 − 2,0) mg/l"},{"name":"范围","range":"(0,064 – 2,60) mg/l NH4+"}],"search_zh":"废水、生活饮用水、水 氨氮浓度 分光光度法 范围 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"废水、生活饮用水、水"},{"_id":"6a5dc9c2f1c10c8ce825f9de","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi, woda","test_object_en":"Wastewater, water intended for human consumption, water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,00 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,00 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda do spożycia przez ludzi, woda Stężenie chlorków\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, woda do spozycia przez ludzi, woda Stezenie chlorkow\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water intended for human consumption, water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 1000) mg/l"}],"search_zh":"废水、生活饮用水、水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"废水、生活饮用水、水"},{"_id":"6a5dc9c2f1c10c8ce825f9df","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi, woda","test_object_en":"Wastewater, water intended for human consumption, water","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT"},{"name":"Zakres","range":"(10,0 – 20 000) mg/l O2"}],"parameters_en":[{"name":"COD"},{"name":"Range","range":"(10,0 – 20 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (10,0 – 20 000) mg/l O2\nMetoda spektrofotometryczna","reference":"P N-ISO15705:2005","norm_bases":["P N-ISO15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda do spożycia przez ludzi, woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (10,0 – 20 000) mg/l O2\nMetoda spektrofotometryczna P N-ISO15705:2005 Scieki, woda do spozycia przez ludzi, woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (10,0 – 20 000) mg/l O2\nMetoda spektrofotometryczna P N-ISO15705:2005","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water intended for human consumption, water Chemical oxygen demand Spectrophotometric method COD Range P N-ISO15705:2005","parameters_zh":[{"name":"化学需氧量（COD）"},{"name":"范围","range":"(10,0 – 20 000) mg/l O2"}],"search_zh":"废水、生活饮用水、水 化学需氧量（COD） 分光光度法 化学需氧量（COD） 范围 P N-ISO15705:2005","technique_zh":"分光光度法","methodology_zh":"化学需氧量（COD）","test_object_zh":"废水、生活饮用水、水"},{"_id":"6a5dc9c2f1c10c8ce825f9e0","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi, woda","test_object_en":"Wastewater, water intended for human consumption, water","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(20,0 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(20,0 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (20,0 – 250) mg/l\nMetoda spektrofotometryczna","reference":"PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99","norm_bases":["PB-08 wydanie II z dnia 25.11 2015 r.","na podstawie testu Hach nr 12065-99"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda do spożycia przez ludzi, woda Stężenie siarczanów\nZakres (20,0 – 250) mg/l\nMetoda spektrofotometryczna PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99 Scieki, woda do spozycia przez ludzi, woda Stezenie siarczanow\nZakres (20,0 – 250) mg/l\nMetoda spektrofotometryczna PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water intended for human consumption, water Sulfate concentration Spectrophotometric method Range PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(20,0 – 250) mg/l"}],"search_zh":"废水、生活饮用水、水 硫酸盐浓度 分光光度法 范围 PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99","technique_zh":"分光光度法","test_object_zh":"废水、生活饮用水、水"},{"_id":"6a5dc9c2f1c10c8ce825f9e1","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi, woda","test_object_en":"Wastewater, water intended for human consumption, water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda do spożycia przez ludzi, woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, woda do spozycia przez ludzi, woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water intended for human consumption, water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"废水、生活饮用水、水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、生活饮用水、水"},{"_id":"6a5dc9c2f1c10c8ce825f9e2","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi, woda","test_object_en":"Wastewater, water intended for human consumption, water","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,020 – 4,0) mg/l"},{"name":"Zakres","range":"(0,066 – 13,2) mg/l NO2 -"}],"parameters_en":[{"name":"Range","range":"(0,020 – 4,0) mg/l"},{"name":"Range","range":"(0,066 – 13,2) mg/l NO2 -"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nZakres (0,066 – 13,2) mg/l NO2 -\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda do spożycia przez ludzi, woda Stężenie azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nZakres (0,066 – 13,2) mg/l NO2 -\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki, woda do spozycia przez ludzi, woda Stezenie azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nZakres (0,066 – 13,2) mg/l NO2 -\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water intended for human consumption, water Nitrite nitrogen concentration Spectrophotometric method Range Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 4,0) mg/l"},{"name":"范围","range":"(0,066 – 13,2) mg/l NO2 -"}],"search_zh":"废水、生活饮用水、水 亚硝态氮浓度 分光光度法 范围 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"废水、生活饮用水、水"},{"_id":"6a5dc9c2f1c10c8ce825f9e3","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","methodology_en":"Sampling for physical and chemical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań fizycznych i chemicznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan fizycznych i chemicznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for physical and chemical testing PN-ISO 5667-5:2017-10","methodology_zh":"物理与化学检测用样品采集","search_zh":"生活饮用水 物理与化学检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9e4","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(20 – 4000) μg/l"}],"parameters_en":[{"name":"Range","range":"(20 – 4000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (20 – 4000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza\nZakres (20 – 4000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza\nZakres (20 – 4000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20 – 4000) μg/l"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9e5","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(15 – 4000) μg/l"}],"parameters_en":[{"name":"Range","range":"(15 – 4000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (15 – 4000) μg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590.03","norm_bases":["PN-92/C-04590.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (15 – 4000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590.03 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (15 – 4000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590.03","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590.03","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 4000) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590.03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9e6","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,20 – 50,0) mg/l"},{"name":"Zakres","range":"(0,89 – 221) mg/l NO3 -"}],"parameters_en":[{"name":"Range","range":"(0,20 – 50,0) mg/l"},{"name":"Range","range":"(0,89 – 221) mg/l NO3 -"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, woda do spozycia przez ludzi Stezenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Nitrate nitrogen concentration Spectrophotometric method Range Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 50,0) mg/l"},{"name":"范围","range":"(0,89 – 221) mg/l NO3 -"}],"search_zh":"水、生活饮用水 硝态氮浓度 分光光度法 范围 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9e7","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(10 – 3900) μS/cm"}],"parameters_en":[{"name":"Range","range":"(10 – 3900) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 3900) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (10 – 3900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (10 – 3900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 3900) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9e8","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(3 – 125) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(3 – 125) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (3 – 125) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (3 – 125) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 Woda, woda do spozycia przez ludzi Barwa\nZakres (3 – 125) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(3 – 125) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9e9","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9ea","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Twardość ogólna","methodology_en":"Total hardness","parameters":[{"name":"Zakres","range":"(5,00 – 600) mg/l CaCO3"},{"name":"Zakres","range":"(0,28 – 33,7) °DH"}],"parameters_en":[{"name":"Range","range":"(5,00 – 600) mg/l CaCO3"},{"name":"Range","range":"(0,28 – 33,7) °DH"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Twardość ogólna\nZakres:\nZakres (5,00 – 600) mg/l CaCO3\nZakres (0,28 – 33,7) °DH\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Twardość ogólna\nZakres:\nZakres (5,00 – 600) mg/l CaCO3\nZakres (0,28 – 33,7) °DH\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Twardosc ogolna\nZakres:\nZakres (5,00 – 600) mg/l CaCO3\nZakres (0,28 – 33,7) °DH\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total hardness Titrimetric method Range Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(5,00 – 600) mg/l CaCO3"},{"name":"范围","range":"(0,28 – 33,7) °DH"}],"search_zh":"水、生活饮用水 总硬度 滴定法 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"总硬度"},{"_id":"6a5dc9c2f1c10c8ce825f9eb","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9ec","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9ed","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9ee","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii enterokoków","methodology_en":"Count of enterococci bacteria","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba bakterii enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water","microbiology"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Count of enterococci bacteria Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水、生活饮用水 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9ef","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 36 oC","methodology_en":"Total viable count at 36 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total viable count at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"36 °C 微生物总数","search_zh":"水、生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f9f0","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22 oC","methodology_en":"Total viable count at 22 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total viable count at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"22 °C 微生物总数","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"}],"has_pdf":true}