{"lab":{"_id":"69ad52a3de79e566650fb49e","accr_number":"AB 920","country":"PL","accr_body":"PCA","address":"ul. Suwalska 64, 19-300 Ełk, LABORATORIUM WODY I ŚCIEKÓW, ul. Ełcka 30","categories":["water","microbiology"],"city":"Ełk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_920.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji sp. z o.o. ul. suwalska 64, 19-300 ełk, laboratorium wody i ścieków, ul. ełcka 30 water other pharma electronics microbiology","status":"active","updated_at":"2026-03-08T14:51:48.761Z","valid_from":"","valid_until":"29.06.2028","website":"","parsed_at":"2026-09-10T00:36:48.646Z","email_confidence":"high","email_mx":true,"email_source":"https://pwikelk.pl/kontakt/","fields_of_testing":[{"codes":"C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling drinking water"},{"codes":"N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"}],"issue":{"no":"17","date":"08.09.2026"},"parse_date":"2026-09-10T00:36:48.646Z","parse_source":"agent-claude-code","map_coord":[53.830946,22.381317],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":60,"microbiology":8},"category_scores":{"water":52.94,"microbiology":0.94},"has_zh":true,"lab_locations":[{"code":null,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","street":"ul. Suwalska 64","postal_code":"19-300","city":"Ełk","is_hq":true,"address":"ul. Suwalska 64, 19-300 Ełk","site":"19-300|suwalska64"},{"code":null,"name":"LABORATORIUM WODY I ŚCIEKÓW","street":"ul. Ełcka 30","postal_code":"19-300","city":"Nowa Wieś Ełcka","is_hq":false,"address":"ul. Ełcka 30, 19-300 Nowa Wieś Ełcka","site":"19-300|ełcka30"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/9/9/50c4cf3c35074c7e597c8a73e1a780fb/AB%20920.pdf"},"methods":[{"_id":"6aa1fba0700e41cc34a0ec2b","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 − 1000) mg/l"},{"name":"Zakres","range":"(1,29 – 1290) mg/l NH4+"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (1,0 − 1000) mg/l\nZakres (1,29 – 1290) mg/l NH4+\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres:\nZakres (1,0 − 1000) mg/l\nZakres (1,29 – 1290) mg/l NH4+\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres:\nZakres (1,0 − 1000) mg/l\nZakres (1,29 – 1290) mg/l NH4+\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec2c","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(5,00 − 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (5,00 − 1000) mg/l\nMetoda miareczkowa","reference":"PB-02 wydanie III z dnia 25.11.2015 r.","norm_bases":["PB-02 wydanie III z dnia 25.11.2015 r."],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (5,00 − 1000) mg/l\nMetoda miareczkowa PB-02 wydanie III z dnia 25.11.2015 r. Scieki Stezenie azotu Kjeldahla\nZakres (5,00 − 1000) mg/l\nMetoda miareczkowa PB-02 wydanie III z dnia 25.11.2015 r.","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec2d","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 – 50,0) mg/l"},{"name":"Zakres","range":"(0,89 – 221) mg/l NO3 -"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec2e","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,07 − 48,9) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,07 − 48,9) mg/l\nMetoda spektrofotometryczna","reference":"PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26","norm_bases":["PB-03 wydanie III z dnia 25.11.2015 r.","na podstawie testu kuwetowego Hach-Lange nr 26"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,07 − 48,9) mg/l\nMetoda spektrofotometryczna PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26 Scieki Stezenie fosforu ogolnego\nZakres (0,07 − 48,9) mg/l\nMetoda spektrofotometryczna PB-03 wydanie III z dnia 25.11.2015 r. | na podstawie testu kuwetowego Hach-Lange nr 26","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec2f","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(3,0 − 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 − 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 − 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 − 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec30","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 − 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec31","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 − 1000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 − 1000) mg/l\nMetoda spektrofotometryczna","reference":"PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.","norm_bases":["PB-07 wydanie I z dnia 04.09.2023 r.","na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338."],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1,0 − 1000) mg/l\nMetoda spektrofotometryczna PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338. Scieki Stezenie azotu ogolnego\nZakres (1,0 − 1000) mg/l\nMetoda spektrofotometryczna PB-07 wydanie I z dnia 04.09.2023 r. | na podstawie testu kuwetowego Hach-Lange nr LCK 138 i LCK 338.","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec32","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec33","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec34","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 − 2,0) mg/l"},{"name":"Zakres","range":"(0,064 – 2,60) mg/l NH4+"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,05 − 2,0) mg/l\nZakres (0,064 – 2,60) mg/l NH4+\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda do spożycia przez ludzi Stężenie azotu amonowego\nZakres:\nZakres (0,05 − 2,0) mg/l\nZakres (0,064 – 2,60) mg/l NH4+\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki, woda do spozycia przez ludzi Stezenie azotu amonowego\nZakres:\nZakres (0,05 − 2,0) mg/l\nZakres (0,064 – 2,60) mg/l NH4+\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec35","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec36","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","parameters":[{"name":"Zakres","range":"(10,0 – 20 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10,0 – 20 000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO15705:2005","norm_bases":["PN-ISO15705:2005"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda do spożycia przez ludzi Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10,0 – 20 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO15705:2005 Scieki, woda do spozycia przez ludzi Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10,0 – 20 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO15705:2005","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec37","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(20,0 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (20,0 – 250) mg/l\nMetoda spektrofotometryczna","reference":"PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99","norm_bases":["PB-08 wydanie II z dnia 25.11 2015 r.","na podstawie testu Hach nr 12065-99"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda do spożycia przez ludzi Stężenie siarczanów\nZakres (20,0 – 250) mg/l\nMetoda spektrofotometryczna PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99 Scieki, woda do spozycia przez ludzi Stezenie siarczanow\nZakres (20,0 – 250) mg/l\nMetoda spektrofotometryczna PB-08 wydanie II z dnia 25.11 2015 r. | na podstawie testu Hach nr 12065-99","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec38","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec39","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Ścieki, woda do spożycia przez ludzi","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,020 – 4,0) mg/l"},{"name":"Zakres","range":"(0,066 – 13,2) mg/l NO2 -"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nZakres (0,066 – 13,2) mg/l NO2 -\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda do spożycia przez ludzi Stężenie azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nZakres (0,066 – 13,2) mg/l NO2 -\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki, woda do spozycia przez ludzi Stezenie azotu azotynowego\nZakres:\nZakres (0,020 – 4,0) mg/l\nZakres (0,066 – 13,2) mg/l NO2 -\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec3a","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań fizycznych i chemicznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan fizycznych i chemicznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec3b","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(20 – 4000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (20 – 4000) µg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (20 – 4000) µg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (20 – 4000) µg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec3c","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(15 – 4000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (15 – 4000) µg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590.03","norm_bases":["PN-92/C-04590.03"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (15 – 4000) µg/l\nMetoda spektrofotometryczna PN-92/C-04590.03 Woda do spozycia przez ludzi Stezenie manganu\nZakres (15 – 4000) µg/l\nMetoda spektrofotometryczna PN-92/C-04590.03","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec3d","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 – 50,0) mg/l"},{"name":"Zakres","range":"(0,89 – 221) mg/l NO3 -"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda do spozycia przez ludzi Stezenie azotu azotanowego\nZakres:\nZakres (0,20 – 50,0) mg/l\nZakres (0,89 – 221) mg/l NO3 -\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec3e","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 3900) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 3900) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (10 – 3900) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (10 – 3900) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec3f","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(3 – 125) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (3 – 125) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (3 – 125) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 Woda do spozycia przez ludzi Barwa\nZakres (3 – 125) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec40","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec41","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Twardość ogólna","parameters":[{"name":"Zakres","range":"(5,00 – 600) mg/l CaCO3"},{"name":"Zakres","range":"(0,28 – 33,7) °DH"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Twardość ogólna\nZakres:\nZakres (5,00 – 600) mg/l CaCO3\nZakres (0,28 – 33,7) °DH\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Twardość ogólna\nZakres:\nZakres (5,00 – 600) mg/l CaCO3\nZakres (0,28 – 33,7) °DH\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Twardosc ogolna\nZakres:\nZakres (5,00 – 600) mg/l CaCO3\nZakres (0,28 – 33,7) °DH\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec42","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec43","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec44","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec45","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków jelitowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków jelitowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec46","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36 ºC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 ºC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 ºC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 ºC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa1fba0700e41cc34a0ec47","lab_id":"69ad52a3de79e566650fb49e","country":"PL","accr_number":"AB 920","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22 ºC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 ºC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 ºC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 ºC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":true}