🇵🇱 ”POLCARGO-MEDYKA” PL

PCA AB 914 • Medyka 161, Poland • 53 methods

Petrochemistry & fuelsWater & wastewater

”POLCARGO-MEDYKA” is a laboratory accredited by PCA under number AB 914 (Medyka 161, Poland). Its accreditation scope covers 53 test methods in the following areas: Petrochemistry & fuels, Water & wastewater. Test objects include: Solid fuels: hard coal, Water, wastewater, Solid fuels: coke, Wastewater. Most frequently used techniques: Gravimetric method, Spectrophotometric method, High-temperature combustion with IR detection.

At a glance

  • Accreditation number: PCA AB 914
  • Methods in scope: 53
  • Types of test objects: 7
  • Techniques used: 13
  • City: Medyka 161, Poland
Accreditation number
AB 914
Accreditation body
PCA
Address
RZECZOZNAWSTWO I KONTROLA TOWARÓW, W OBROCIE MIĘDZYNARODOWYM Sp. z o.o., 37-732 Medyka 161
City
Medyka 161, Poland

What this laboratory tests (7)

Analytical techniques used (13)

Laboratory sections (2)

Laboratory locations

Accreditation scope — test methods (53)

No. Test object Methodology / Parameters Technique Reference document
Laboratorium Chemiczne i Ochrony Środowiska w Medyce
1 Water, wastewater Chemical oxygen demand COD – Cr
Range (30 – 10000) mg/l O2
Titrimetric method PN-ISO 6060:2006
2 Water, wastewater Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
3 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007 + Ap1:2007
4 Water, wastewater Temperature of the collected water, wastewater sample
Range (5,0 – 35) ºC
Regulated area: Badania wykonywane poza siedzibą Laboratorium
Direct measurement method PN-77/C-04584
5 Water, wastewater Ammonium nitrogen concentration
Range (0,040 – 100) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
6 Water, wastewater Nitrate nitrogen concentration
Range (0,10 – 50) mg/l
Spectrophotometric method PN-82/C-04576/08
7 Water, wastewater Nitrite nitrogen concentration
Range (0,010 – 5) mg/l
Spectrophotometric method PN-EN 26777:1999
8 Water, wastewater Iron concentration
Range (0,040 – 15) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap.1:2016-06
9 Water, wastewater Electrical conductivity
Range (100 – 10000) μS/cm
Regulated area: Badania wykonywane w siedzibie Laboratorium i poza nią
Conductometric method PN-EN 27888:1999
10 Water, wastewater Biochemical oxygen demand - BOD5
Range (1 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
11 Water, wastewater Biochemical oxygen demand - BOD5
Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
12 Water, wastewater pH
Range 2,0 – 10,0
Regulated area: Badania wykonywane w siedzibie Laboratorium i poza nią
Potentiometric method PN-EN ISO 10523:2012
13 Water Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 Metoda D +Ap1:2015
14 Water Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
15 Water Manganese concentration
Range (0,020 – 1,0) mg/l
Spectrophotometric method PN-92/C-04590.03
16 Wastewater Total phosphorus concentration
Range (0,050 – 40) mg/l
Spectrophotometric method PN-EN ISO 6878:2006, pkt. 8 + Ap1:2010 + Ap2:2010
17 Wastewater Sulfate concentration
Range (10 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
18 Wastewater Kjeldahl nitrogen concentration
Range (1,0 – 300) mg/l
Titrimetric method PN-EN 25663:2001
19 Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
20 Iron ore Total iron content
Range (40 – 72) %
Titrimetric method ISO 2597-2:2015
21 Water, Water intended for human consumption Sulfate concentration
Range (10 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
22 Water, Water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06
23 Water, Water intended for human consumption Free chlorine concentration
Range (0,1 – 1,0) mg/l
Regulated area: Badania wykonywane poza siedzibą Laboratorium
Spectrophotometric method PN-EN ISO 7393-2:2018-04
Laboratorium Chemiczne w Sławkowie
24 Solid fuels: hard coal Free moisture content
Range (3,00 – 30,00) %
Gravimetric method PN-80/G-04511 pkt. 2.1
25 Solid fuels: hard coal Moisture content in the analytical sample
Range (0,50 – 20,00) %
Gravimetric method PN-80/G-04511 pkt. 2.4.1.7.a
26 Solid fuels: hard coal Moisture content in air-dried coal
Range (0,50 – 20,00) %
Gravimetric method PN-80/G-04511 pkt. 2.2.1
27 Solid fuels: hard coal Total moisture content (calculated) PN-80/G-04511 pkt. 2.3.1
28 Solid fuels: hard coal Ash content
Range (2,00 – 50,00) %
Gravimetric method PN-80/G-04512 + Az1:2002 pkt. 2.4.1
29 Solid fuels: hard coal Volatile matter content
Range (0,90 – 40,00) %
Gravimetric method PN-G-04516:1998
30 Solid fuels: hard coal Gross calorific value
Range (9000 – 40000) kJ/kg
Calorimetric method PN-81/G-04513
31 Solid fuels: hard coal Net calorific value (calculated) PN-81/G-04513
32 Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006 metoda A1
33 Solid fuels: hard coal First-stage moisture content (free moisture)
Range (3,00 – 30,00) %
Gravimetric method PN-ISO 589:2006
34 Solid fuels: hard coal Second-stage moisture content (moisture in air-dried coal)
Range (0,50 – 20,00) %
Gravimetric method PN-ISO 589:2006 metoda A1
35 Solid fuels: hard coal Moisture content in the analytical sample
Range (0,50 – 14,00) %
Gravimetric method PN-ISO 11722:2009
36 Solid fuels: hard coal Ash content
Range (2,00 – 50,00) %
Gravimetric method PN-ISO 1171:2002
37 Solid fuels: hard coal Volatile matter content
Range (0,90 – 40,00) %
Gravimetric method ISO 562:2010
38 Solid fuels: hard coal Gross calorific value
Range (9000 – 36000) kJ/kg
Calorimetric method PN-ISO 1928:2020-05
39 Solid fuels: hard coal Net calorific value (calculated) PN-ISO 1928:2020-05
40 Solid fuels: hard coal Total carbon, hydrogen content
C (40,00 – 90,00) % H (0,20 – 10,00) %
High-temperature combustion with IR detection PN-G-04571:1998
41 Solid fuels: hard coal Nitrogen content
Range (0,70 – 3,00) %
High-temperature combustion with TC detection PN-G-04571:1998
42 Solid fuels: hard coal Total sulfur content
Range (0,10 – 3,00) %
High-temperature combustion with IR detection PN-G-04584:2001
43 Solid fuels: hard coal Total sulfur content
Range (0,10 – 3,50)%
High-temperature combustion with IR detection ISO 19579:2006
44 Solid fuels: hard coal Caking power RI
Range 0 – 90
Roga method PN-G-04508:2020-05
45 Solid fuels: coke Gross calorific value
Range (9000 – 36000) kJ/kg
Calorimetric method PN-ISO 1928:2020-05
46 Solid fuels: coke Net calorific value (calculated) PN-ISO 1928:2020-05
47 Solid fuels: coke Ash content
Range (0,10 – 20,00) %
Gravimetric method PN-ISO 1171:2002
48 Solid fuels: coke Volatile matter content
Range (0,10 – 10,00) %
Gravimetric method ISO 562:2010
49 Solid fuels: coke Total moisture content
Range (0,10 – 20,00) %
Gravimetric method PN-ISO 579:2002
50 Solid fuels: coke Moisture content in the analytical sample
Range (0,10 – 3,00) %
Gravimetric method PN-80/G-04511 pkt. 2.4.2
51 Solid fuels: coke Moisture content in the analytical sample
Range (0,10 – 5,00) %
Gravimetric method PN-ISO 687:2005
52 Solid fuels: coke Total sulfur content
Range (0,10 – 5,00) %
High-temperature combustion with IR detection PN-G-04584:2001
53 Solid fuels: coke Total sulfur content
Range (0,10 – 2,00)%
High-temperature combustion with IR detection ISO 19579:2006

Reference standards (42)

ISO 19579:2006
ISO 2597-2:2015
ISO 562:2010
PN-73/C-04576/14
PN-77/C-04584
PN-80/G-04511 pkt. 2.1
PN-80/G-04511 pkt. 2.2.1
PN-80/G-04511 pkt. 2.3.1
PN-80/G-04511 pkt. 2.4.1.7.a
PN-80/G-04511 pkt. 2.4.2
PN-80/G-04512 + Az1:2002 pkt. 2.4.1
PN-81/G-04513
PN-82/C-04576/08
PN-92/C-04590.03
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006, pkt. 8 + Ap1:2010 + Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06
PN-EN ISO 7887:2012 Metoda D +Ap1:2015
PN-G-04508:2020-05
PN-G-04516:1998
PN-G-04571:1998
PN-G-04584:2001
PN-ISO 1171:2002
PN-ISO 11722:2009
PN-ISO 1928:2020-05
PN-ISO 579:2002
PN-ISO 589:2006
PN-ISO 589:2006 metoda A1
PN-ISO 6060:2006
PN-ISO 6332:2001+Ap.1:2016-06
PN-ISO 687:2005
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994