{"lab":{"_id":"69ad52a3de79e566650fb49a","accr_number":"AB 914","country":"PL","accr_body":"PCA","address":"RZECZOZNAWSTWO I KONTROLA TOWARÓW, W OBROCIE MIĘDZYNARODOWYM Sp. z o.o., 37-732 Medyka 161","categories":["petro","water"],"city":"Medyka 161","imported_at":"2026-03-08T10:42:43.265Z","methods_count":53,"name":"”POLCARGO-MEDYKA”","parse_status":"parsed","parse_version":3,"pdf_files":["AB_914.pdf"],"scope_summary":"","search_text":"”polcargo-medyka” rzeczoznawstwo i kontrola towarów, w obrocie międzynarodowym sp. z o.o., 37-732 medyka 161 water other pharma electronics petro materials","status":"active","updated_at":"2026-03-08T14:51:48.588Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:33:50.391Z","email_confidence":"high","email_mx":true,"email_source":"https://polcargo-medyka.pl/index.php/kontakt/","fields_of_testing":[{"codes":"C/8; C/10; C/28; C/29; C/30","pl":"Badania chemiczne wyrobów i materiałów konstrukcyjnych, paliw stałych, wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests of construction products and materials, solid fuels, water, drinking water, sewage"},{"codes":"N/10; N/28; N/29; N/30","pl":"Badania właściwości fizycznych paliw stałych, wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties of solid fuels, water, drinking water, sewage"}],"issue":{"no":"21","date":"16.03.2026"},"parse_date":"2026-08-18T01:33:50.391Z","parse_source":"agent-claude-code","lab_locations":[{"name":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","address":"37-732 Medyka 161","city":"Medyka","postal":"37-732"},{"name":"Laboratorium Chemiczne w Sławkowie","address":"ul. Słowackiego 2A, 41-260 Sławków","city":"Sławków","postal":"41-260"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/0d06da05fe0ea412759c5b66ab030857/AB%20914.pdf","has_en":true,"category_counts":{"petro":30,"water":22,"other":1},"category_scores":{"petro":16.98,"water":9.13,"other":0.02},"has_zh":true},"methods":[{"_id":"6a83b67eaf14b9c0e7b20f05","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu ChZT – Cr","parameters":[{"name":"Zakres","range":"(30 – 10000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT – Cr\nZakres (30 – 10000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu ChZT – Cr\nZakres (30 – 10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, scieki Chemiczne zapotrzebowanie tlenu ChZT – Cr\nZakres (30 – 10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand COD – Cr","parameters_en":[{"name":"Range","range":"(30 – 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand COD – Cr Titrimetric method Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(30 – 10000) mg/l O2"}],"search_zh":"水、废水 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a83b67eaf14b9c0e7b20f06","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a83b67eaf14b9c0e7b20f07","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 + Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a83b67eaf14b9c0e7b20f08","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Temperatura pobranej próbki wody, ścieków","parameters":[{"name":"Zakres","range":"(5,0 – 35) ºC"}],"technique":"Metoda pomiaru bezpośredniego","techniques":["Metoda pomiaru bezpośredniego"],"computed":[],"activity":"Temperatura pobranej próbki wody, ścieków\nZakres (5,0 – 35) ºC\nMetoda pomiaru bezpośredniego","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, ścieki Temperatura pobranej próbki wody, ścieków\nZakres (5,0 – 35) ºC\nMetoda pomiaru bezpośredniego PN-77/C-04584 Woda, scieki Temperatura pobranej probki wody, sciekow\nZakres (5,0 – 35) ºC\nMetoda pomiaru bezposredniego PN-77/C-04584","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected water, wastewater sample","parameters_en":[{"name":"Range","range":"(5,0 – 35) ºC"}],"search_en":"Water, wastewater Temperature of the collected water, wastewater sample Direct measurement method Range PN-77/C-04584","technique_en":"Direct measurement method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(5,0 – 35) ºC"}],"search_zh":"水、废水 直接测量法 范围 PN-77/C-04584","test_object_zh":"水、废水","technique_zh":"直接测量法"},{"_id":"6a83b67eaf14b9c0e7b20f09","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,040 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,040 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,040 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,040 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,040 – 100) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 100) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a83b67eaf14b9c0e7b20f0a","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,10 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,10 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a83b67eaf14b9c0e7b20f0b","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,010 – 5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,010 – 5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 5) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 5) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a83b67eaf14b9c0e7b20f0c","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,040 – 15) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,040 – 15) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap.1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap.1:2016-06"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie żelaza\nZakres (0,040 – 15) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap.1:2016-06 Woda, scieki Stezenie zelaza\nZakres (0,040 – 15) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap.1:2016-06","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,040 – 15) mg/l"}],"search_en":"Water, wastewater Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap.1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 15) mg/l"}],"search_zh":"水、废水 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap.1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a83b67eaf14b9c0e7b20f0d","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 10000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 10000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":"Badania wykonywane w siedzibie Laboratorium i poza nią","flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (100 – 10000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (100 – 10000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 10000) μS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 10000) μS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a83b67eaf14b9c0e7b20f0e","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a83b67eaf14b9c0e7b20f0f","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a83b67eaf14b9c0e7b20f10","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":"Badania wykonywane w siedzibie Laboratorium i poza nią","flexible":false,"search_text":"Woda, ścieki pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a83b67eaf14b9c0e7b20f11","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 Metoda D +Ap1:2015","norm_bases":["PN-EN ISO 7887:2012 Metoda D +Ap1:2015"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 Metoda D +Ap1:2015 Woda Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 Metoda D +Ap1:2015","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"search_en":"Water Colour Visual method Range PN-EN ISO 7887:2012 Metoda D +Ap1:2015","technique_en":"Visual method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"水 色度 目视法 范围 PN-EN ISO 7887:2012 Metoda D +Ap1:2015","technique_zh":"目视法","test_object_zh":"水"},{"_id":"6a83b67eaf14b9c0e7b20f12","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"search_en":"Water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水"},{"_id":"6a83b67eaf14b9c0e7b20f13","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,020 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,020 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590.03","norm_bases":["PN-92/C-04590.03"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie manganu\nZakres (0,020 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590.03 Woda Stezenie manganu\nZakres (0,020 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590.03","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,020 – 1,0) mg/l"}],"search_en":"Water Manganese concentration Spectrophotometric method Range PN-92/C-04590.03","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 1,0) mg/l"}],"search_zh":"水 锰浓度 分光光度法 范围 PN-92/C-04590.03","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a83b67eaf14b9c0e7b20f14","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,050 – 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050 – 40) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006, pkt. 8 + Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006, pkt. 8 + Ap1:2010 + Ap2:2010"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,050 – 40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006, pkt. 8 + Ap1:2010 + Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,050 – 40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006, pkt. 8 + Ap1:2010 + Ap2:2010","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,050 – 40) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006, pkt. 8 + Ap1:2010 + Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 40) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006, pkt. 8 + Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83b67eaf14b9c0e7b20f15","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie siarczanów\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"search_en":"Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a83b67eaf14b9c0e7b20f16","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 300) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 300) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 300) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 300) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 300) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a83b67eaf14b9c0e7b20f17","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","test_object_en":"Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"污水"},{"_id":"6a83b67eaf14b9c0e7b20f18","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Ruda żelaza","methodology":"Zawartość żelaza całkowitego","parameters":[{"name":"Zakres","range":"(40 – 72) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość żelaza całkowitego\nZakres (40 – 72) %\nMetoda miareczkowa","reference":"ISO 2597-2:2015","norm_bases":["ISO 2597-2:2015"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ruda żelaza Zawartość żelaza całkowitego\nZakres (40 – 72) %\nMetoda miareczkowa ISO 2597-2:2015 Ruda zelaza Zawartosc zelaza calkowitego\nZakres (40 – 72) %\nMetoda miareczkowa ISO 2597-2:2015","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron content","parameters_en":[{"name":"Range","range":"(40 – 72) %"}],"search_en":"Iron ore Total iron content Titrimetric method Range ISO 2597-2:2015","technique_en":"Titrimetric method","test_object_en":"Iron ore","parameters_zh":[{"name":"范围","range":"(40 – 72) %"}],"search_zh":"滴定法 范围 ISO 2597-2:2015","technique_zh":"滴定法"},{"_id":"6a83b67eaf14b9c0e7b20f19","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"search_en":"Water, Water intended for human consumption Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"水、生活饮用水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b67eaf14b9c0e7b20f1a","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06 Woda, Woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b67eaf14b9c0e7b20f1b","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,1 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,1 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium Chemiczne i Ochrony Środowiska w Medyce","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,1 – 1,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda, Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,1 – 1,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,1 – 1,0) mg/l"}],"search_en":"Water, Water intended for human consumption Free chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 游离氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b67eaf14b9c0e7b20f1c","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci przemijającej","parameters":[{"name":"Zakres","range":"(3,00 – 30,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci przemijającej\nZakres (3,00 – 30,00) %\nMetoda wagowa","reference":"PN-80/G-04511 pkt. 2.1","norm_bases":["PN-80/G-04511 pkt. 2.1"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci przemijającej\nZakres (3,00 – 30,00) %\nMetoda wagowa PN-80/G-04511 pkt. 2.1 Paliwa stale: wegiel kamienny Zawartosc wilgoci przemijajacej\nZakres (3,00 – 30,00) %\nMetoda wagowa PN-80/G-04511 pkt. 2.1","categories":["petro"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free moisture content","parameters_en":[{"name":"Range","range":"(3,00 – 30,00) %"}],"search_en":"Solid fuels: hard coal Free moisture content Gravimetric method Range PN-80/G-04511 pkt. 2.1","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(3,00 – 30,00) %"}],"search_zh":"固体燃料：烟煤 外在水分含量 重量法 范围 PN-80/G-04511 pkt. 2.1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"外在水分含量"},{"_id":"6a83b67eaf14b9c0e7b20f1d","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,50 – 20,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 20,00) %\nMetoda wagowa","reference":"PN-80/G-04511 pkt. 2.4.1.7.a","norm_bases":["PN-80/G-04511 pkt. 2.4.1.7.a"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 20,00) %\nMetoda wagowa PN-80/G-04511 pkt. 2.4.1.7.a Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,50 – 20,00) %\nMetoda wagowa PN-80/G-04511 pkt. 2.4.1.7.a","categories":["petro"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,50 – 20,00) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-80/G-04511 pkt. 2.4.1.7.a","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,50 – 20,00) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-80/G-04511 pkt. 2.4.1.7.a","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b67eaf14b9c0e7b20f1e","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w węglu powietrznosuchym","parameters":[{"name":"Zakres","range":"(0,50 – 20,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w węglu powietrznosuchym\nZakres (0,50 – 20,00) %\nMetoda wagowa","reference":"PN-80/G-04511 pkt. 2.2.1","norm_bases":["PN-80/G-04511 pkt. 2.2.1"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w węglu powietrznosuchym\nZakres (0,50 – 20,00) %\nMetoda wagowa PN-80/G-04511 pkt. 2.2.1 Paliwa stale: wegiel kamienny Zawartosc wilgoci w weglu powietrznosuchym\nZakres (0,50 – 20,00) %\nMetoda wagowa PN-80/G-04511 pkt. 2.2.1","categories":["petro"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in air-dried coal","parameters_en":[{"name":"Range","range":"(0,50 – 20,00) %"}],"search_en":"Solid fuels: hard coal Moisture content in air-dried coal Gravimetric method Range PN-80/G-04511 pkt. 2.2.1","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,50 – 20,00) %"}],"search_zh":"固体燃料：烟煤 重量法 范围 PN-80/G-04511 pkt. 2.2.1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b67eaf14b9c0e7b20f1f","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-80/G-04511 pkt. 2.3.1","norm_bases":["PN-80/G-04511 pkt. 2.3.1"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-80/G-04511 pkt. 2.3.1 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-80/G-04511 pkt. 2.3.1","categories":["petro"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-80/G-04511 pkt. 2.3.1","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-80/G-04511 pkt. 2.3.1","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a83b67eaf14b9c0e7b20f20","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(2,00 – 50,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (2,00 – 50,00) %\nMetoda wagowa","reference":"PN-80/G-04512 + Az1:2002 pkt. 2.4.1","norm_bases":["PN-80/G-04512 + Az1:2002 pkt. 2.4.1"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (2,00 – 50,00) %\nMetoda wagowa PN-80/G-04512 + Az1:2002 pkt. 2.4.1 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (2,00 – 50,00) %\nMetoda wagowa PN-80/G-04512 + Az1:2002 pkt. 2.4.1","categories":["petro"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(2,00 – 50,00) %"}],"search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-80/G-04512 + Az1:2002 pkt. 2.4.1","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(2,00 – 50,00) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-80/G-04512 + Az1:2002 pkt. 2.4.1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b67eaf14b9c0e7b20f21","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(0,90 – 40,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (0,90 – 40,00) %\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (0,90 – 40,00) %\nMetoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (0,90 – 40,00) %\nMetoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(0,90 – 40,00) %"}],"search_en":"Solid fuels: hard coal Volatile matter content Gravimetric method Range PN-G-04516:1998","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,90 – 40,00) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 重量法 范围 PN-G-04516:1998","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"挥发分含量"},{"_id":"6a83b67eaf14b9c0e7b20f22","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(9000 – 40000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (9000 – 40000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-81/G-04513","norm_bases":["PN-81/G-04513"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres (9000 – 40000) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres (9000 – 40000) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513","categories":["petro"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(9000 – 40000) kJ/kg"}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range PN-81/G-04513","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(9000 – 40000) kJ/kg"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 PN-81/G-04513","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b67eaf14b9c0e7b20f23","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-81/G-04513","norm_bases":["PN-81/G-04513"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Wartość opałowa (z obliczeń) PN-81/G-04513 Paliwa stale: wegiel kamienny Wartosc opalowa (z obliczen) PN-81/G-04513","categories":["petro"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: hard coal Net calorific value (calculated) PN-81/G-04513","test_object_en":"Solid fuels: hard coal","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：烟煤 低位发热量（计算值） PN-81/G-04513","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b67eaf14b9c0e7b20f24","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006 metoda A1","norm_bases":["PN-ISO 589:2006 metoda A1"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006 metoda A1 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006 metoda A1","categories":["petro"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006 metoda A1","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-ISO 589:2006 metoda A1","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a83b67eaf14b9c0e7b20f25","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)","parameters":[{"name":"Zakres","range":"(3,00 – 30,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nZakres (3,00 – 30,00) %\nMetoda wagowa","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nZakres (3,00 – 30,00) %\nMetoda wagowa PN-ISO 589:2006 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (wilgoci przemijajacej)\nZakres (3,00 – 30,00) %\nMetoda wagowa PN-ISO 589:2006","categories":["petro"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"First-stage moisture content (free moisture)","parameters_en":[{"name":"Range","range":"(3,00 – 30,00) %"}],"search_en":"Solid fuels: hard coal First-stage moisture content (free moisture) Gravimetric method Range PN-ISO 589:2006","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(3,00 – 30,00) %"}],"search_zh":"固体燃料：烟煤 第一阶段水分（外在水分）含量 重量法 范围 PN-ISO 589:2006","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a83b67eaf14b9c0e7b20f26","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci drugiego stopnia (wilgoci w węglu powietrznosuchym)","parameters":[{"name":"Zakres","range":"(0,50 – 20,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoci w węglu powietrznosuchym)\nZakres (0,50 – 20,00) %\nMetoda wagowa","reference":"PN-ISO 589:2006 metoda A1","norm_bases":["PN-ISO 589:2006 metoda A1"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoci w węglu powietrznosuchym)\nZakres (0,50 – 20,00) %\nMetoda wagowa PN-ISO 589:2006 metoda A1 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoci w weglu powietrznosuchym)\nZakres (0,50 – 20,00) %\nMetoda wagowa PN-ISO 589:2006 metoda A1","categories":["petro"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Second-stage moisture content (moisture in air-dried coal)","parameters_en":[{"name":"Range","range":"(0,50 – 20,00) %"}],"search_en":"Solid fuels: hard coal Second-stage moisture content (moisture in air-dried coal) Gravimetric method Range PN-ISO 589:2006 metoda A1","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,50 – 20,00) %"}],"search_zh":"固体燃料：烟煤 重量法 范围 PN-ISO 589:2006 metoda A1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b67eaf14b9c0e7b20f27","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,50 – 14,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 14,00) %\nMetoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 14,00) %\nMetoda wagowa PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,50 – 14,00) %\nMetoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,50 – 14,00) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-ISO 11722:2009","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,50 – 14,00) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-ISO 11722:2009","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b67eaf14b9c0e7b20f28","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(2,00 – 50,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (2,00 – 50,00) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (2,00 – 50,00) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (2,00 – 50,00) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(2,00 – 50,00) %"}],"search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(2,00 – 50,00) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b67eaf14b9c0e7b20f29","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(0,90 – 40,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (0,90 – 40,00) %\nMetoda wagowa","reference":"ISO 562:2010","norm_bases":["ISO 562:2010"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (0,90 – 40,00) %\nMetoda wagowa ISO 562:2010 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (0,90 – 40,00) %\nMetoda wagowa ISO 562:2010","categories":["petro"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(0,90 – 40,00) %"}],"search_en":"Solid fuels: hard coal Volatile matter content Gravimetric method Range ISO 562:2010","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,90 – 40,00) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 重量法 范围 ISO 562:2010","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"挥发分含量"},{"_id":"6a83b67eaf14b9c0e7b20f2a","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(9000 – 36000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (9000 – 36000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres (9000 – 36000) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres (9000 – 36000) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(9000 – 36000) kJ/kg"}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range PN-ISO 1928:2020-05","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(9000 – 36000) kJ/kg"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b67eaf14b9c0e7b20f2b","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Wartość opałowa (z obliczeń) PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Wartosc opalowa (z obliczen) PN-ISO 1928:2020-05","categories":["petro"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: hard coal Net calorific value (calculated) PN-ISO 1928:2020-05","test_object_en":"Solid fuels: hard coal","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：烟煤 低位发热量（计算值） PN-ISO 1928:2020-05","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b67eaf14b9c0e7b20f2c","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość węgla całkowitego, wodoru","parameters":[{"name":"C","range":"(40,00 – 90,00) %"},{"name":"H","range":"(0,20 – 10,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego, wodoru\nZakres:\nC (40,00 – 90,00) %\nH (0,20 – 10,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego, wodoru\nZakres:\nC (40,00 – 90,00) %\nH (0,20 – 10,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego, wodoru\nZakres:\nC (40,00 – 90,00) %\nH (0,20 – 10,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon, hydrogen content","parameters_en":[{"name":"C","range":"(40,00 – 90,00) %"},{"name":"H","range":"(0,20 – 10,00) %"}],"search_en":"Solid fuels: hard coal Total carbon, hydrogen content High-temperature combustion with IR detection C H PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 全碳与氢含量 高温燃烧红外检测法 C PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","parameters_zh":[{"name":"C","range":"(40,00 – 90,00) %"},{"name":"H","range":"(0,20 – 10,00) %"}],"methodology_zh":"全碳与氢含量"},{"_id":"6a83b67eaf14b9c0e7b20f2d","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,70 – 3,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu\nZakres (0,70 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość azotu\nZakres (0,70 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc azotu\nZakres (0,70 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-G-04571:1998","categories":["petro"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,70 – 3,00) %"}],"search_en":"Solid fuels: hard coal Nitrogen content High-temperature combustion with TC detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,70 – 3,00) %"}],"search_zh":"固体燃料：烟煤 氮含量 高温燃烧总碳检测法 范围 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a83b67eaf14b9c0e7b20f2e","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 3,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 3,00) %"}],"search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 3,00) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b67eaf14b9c0e7b20f2f","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 3,50)%"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 3,50)%\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 19579:2006","norm_bases":["ISO 19579:2006"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,10 – 3,50)%\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 19579:2006 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,10 – 3,50)%\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 19579:2006","categories":["petro"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 3,50)%"}],"search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 3,50)%"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b67eaf14b9c0e7b20f30","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zdolność spiekania RI","parameters":[{"name":"Zakres","range":"0 – 90"}],"technique":"Metoda Rogi","techniques":["Metoda Rogi"],"computed":[],"activity":"Zdolność spiekania RI\nZakres 0 – 90\nMetoda Rogi","reference":"PN-G-04508:2020-05","norm_bases":["PN-G-04508:2020-05"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zdolność spiekania RI\nZakres 0 – 90\nMetoda Rogi PN-G-04508:2020-05 Paliwa stale: wegiel kamienny Zdolnosc spiekania RI\nZakres 0 – 90\nMetoda Rogi PN-G-04508:2020-05","categories":["petro"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Caking power RI","parameters_en":[{"name":"Range","range":"0 – 90"}],"search_en":"Solid fuels: hard coal Caking power RI Roga method Range PN-G-04508:2020-05","technique_en":"Roga method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"0 – 90"}],"search_zh":"固体燃料：烟煤 罗加法（Roga） 范围 PN-G-04508:2020-05","test_object_zh":"固体燃料：烟煤","technique_zh":"罗加法（Roga）"},{"_id":"6a83b67eaf14b9c0e7b20f31","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: koks","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(9000 – 36000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (9000 – 36000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks Ciepło spalania\nZakres (9000 – 36000) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale: koks Cieplo spalania\nZakres (9000 – 36000) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(9000 – 36000) kJ/kg"}],"search_en":"Solid fuels: coke Gross calorific value Calorimetric method Range PN-ISO 1928:2020-05","technique_en":"Calorimetric method","test_object_en":"Solid fuels: coke","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(9000 – 36000) kJ/kg"}],"search_zh":"固体燃料：焦炭 高位发热量 量热法 范围 PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：焦炭"},{"_id":"6a83b67eaf14b9c0e7b20f32","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: koks","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks Wartość opałowa (z obliczeń) PN-ISO 1928:2020-05 Paliwa stale: koks Wartosc opalowa (z obliczen) PN-ISO 1928:2020-05","categories":["petro"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: coke Net calorific value (calculated) PN-ISO 1928:2020-05","test_object_en":"Solid fuels: coke","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：焦炭 低位发热量（计算值） PN-ISO 1928:2020-05","test_object_zh":"固体燃料：焦炭"},{"_id":"6a83b67eaf14b9c0e7b20f33","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: koks","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,10 – 20,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,10 – 20,00) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks Zawartość popiołu\nZakres (0,10 – 20,00) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: koks Zawartosc popiolu\nZakres (0,10 – 20,00) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,10 – 20,00) %"}],"search_en":"Solid fuels: coke Ash content Gravimetric method Range PN-ISO 1171:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: coke","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 20,00) %"}],"search_zh":"固体燃料：焦炭 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：焦炭"},{"_id":"6a83b67eaf14b9c0e7b20f34","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: koks","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(0,10 – 10,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (0,10 – 10,00) %\nMetoda wagowa","reference":"ISO 562:2010","norm_bases":["ISO 562:2010"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks Zawartość części lotnych\nZakres (0,10 – 10,00) %\nMetoda wagowa ISO 562:2010 Paliwa stale: koks Zawartosc czesci lotnych\nZakres (0,10 – 10,00) %\nMetoda wagowa ISO 562:2010","categories":["petro"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(0,10 – 10,00) %"}],"search_en":"Solid fuels: coke Volatile matter content Gravimetric method Range ISO 562:2010","technique_en":"Gravimetric method","test_object_en":"Solid fuels: coke","parameters_zh":[{"name":"范围","range":"(0,10 – 10,00) %"}],"search_zh":"固体燃料：焦炭 挥发分含量 重量法 范围 ISO 562:2010","technique_zh":"重量法","methodology_zh":"挥发分含量","test_object_zh":"固体燃料：焦炭"},{"_id":"6a83b67eaf14b9c0e7b20f35","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: koks","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 20,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (0,10 – 20,00) %\nMetoda wagowa","reference":"PN-ISO 579:2002","norm_bases":["PN-ISO 579:2002"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks Zawartość wilgoci całkowitej\nZakres (0,10 – 20,00) %\nMetoda wagowa PN-ISO 579:2002 Paliwa stale: koks Zawartosc wilgoci calkowitej\nZakres (0,10 – 20,00) %\nMetoda wagowa PN-ISO 579:2002","categories":["petro"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(0,10 – 20,00) %"}],"search_en":"Solid fuels: coke Total moisture content Gravimetric method Range PN-ISO 579:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: coke","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 20,00) %"}],"search_zh":"固体燃料：焦炭 全水分含量 重量法 范围 PN-ISO 579:2002","technique_zh":"重量法","test_object_zh":"固体燃料：焦炭"},{"_id":"6a83b67eaf14b9c0e7b20f36","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: koks","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,10 – 3,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 3,00) %\nMetoda wagowa","reference":"PN-80/G-04511 pkt. 2.4.2","norm_bases":["PN-80/G-04511 pkt. 2.4.2"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 3,00) %\nMetoda wagowa PN-80/G-04511 pkt. 2.4.2 Paliwa stale: koks Zawartosc wilgoci w probce analitycznej\nZakres (0,10 – 3,00) %\nMetoda wagowa PN-80/G-04511 pkt. 2.4.2","categories":["petro"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,10 – 3,00) %"}],"search_en":"Solid fuels: coke Moisture content in the analytical sample Gravimetric method Range PN-80/G-04511 pkt. 2.4.2","technique_en":"Gravimetric method","test_object_en":"Solid fuels: coke","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 3,00) %"}],"search_zh":"固体燃料：焦炭 分析样品水分含量 重量法 范围 PN-80/G-04511 pkt. 2.4.2","technique_zh":"重量法","test_object_zh":"固体燃料：焦炭"},{"_id":"6a83b67eaf14b9c0e7b20f37","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: koks","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,10 – 5,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 5,00) %\nMetoda wagowa","reference":"PN-ISO 687:2005","norm_bases":["PN-ISO 687:2005"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 5,00) %\nMetoda wagowa PN-ISO 687:2005 Paliwa stale: koks Zawartosc wilgoci w probce analitycznej\nZakres (0,10 – 5,00) %\nMetoda wagowa PN-ISO 687:2005","categories":["petro"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,10 – 5,00) %"}],"search_en":"Solid fuels: coke Moisture content in the analytical sample Gravimetric method Range PN-ISO 687:2005","technique_en":"Gravimetric method","test_object_en":"Solid fuels: coke","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 5,00) %"}],"search_zh":"固体燃料：焦炭 分析样品水分含量 重量法 范围 PN-ISO 687:2005","technique_zh":"重量法","test_object_zh":"固体燃料：焦炭"},{"_id":"6a83b67eaf14b9c0e7b20f38","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: koks","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 5,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 5,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks Zawartość siarki całkowitej\nZakres (0,10 – 5,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: koks Zawartosc siarki calkowitej\nZakres (0,10 – 5,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 5,00) %"}],"search_en":"Solid fuels: coke Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: coke","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 5,00) %"}],"search_zh":"固体燃料：焦炭 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：焦炭"},{"_id":"6a83b67eaf14b9c0e7b20f39","lab_id":"69ad52a3de79e566650fb49a","country":"PL","accr_number":"AB 914","accr_body":"PCA","test_object":"Paliwa stałe: koks","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 2,00)%"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 2,00)%\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 19579:2006","norm_bases":["ISO 19579:2006"],"lab_section":"Laboratorium Chemiczne w Sławkowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks Zawartość siarki całkowitej\nZakres (0,10 – 2,00)%\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 19579:2006 Paliwa stale: koks Zawartosc siarki calkowitej\nZakres (0,10 – 2,00)%\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 19579:2006","categories":["petro"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 2,00)%"}],"search_en":"Solid fuels: coke Total sulfur content High-temperature combustion with IR detection Range ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: coke","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 2,00)%"}],"search_zh":"固体燃料：焦炭 全硫含量 高温燃烧红外检测法 范围 ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：焦炭"}],"has_pdf":true}