🇵🇱 GRUPA INTERLIS Sp. z o.o. PL

PCA AB 896 • Kalisz, Poland • 82 methods

EnvironmentElectronics & EMC

GRUPA INTERLIS Sp. z o.o. is a laboratory accredited by PCA under number AB 896 (Kalisz, Poland). Its accreditation scope covers 82 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Workplace environment - air, Workplace environment - noise, Workplace environment - indoor electric lighting, Workplace environment - emergency lighting. Most frequently used techniques: Direct measurement method, Gravimetric method, Personal dosimetry method.

At a glance

  • Accreditation number: PCA AB 896
  • Methods in scope: 82
  • Types of test objects: 17
  • Techniques used: 8
  • City: Kalisz, Poland
Accreditation number
AB 896
Accreditation body
PCA
Address
ul. Ptolemeusza 10, 62-800 Kalisz, LABORATORIUM BADAŃ ŚRODOWISKA PRACY, ul. Zielona 18
City
Kalisz, Poland

What this laboratory tests (17)

Analytical techniques used (8)

Laboratory sections (2)

Laboratory locations

Accreditation scope — test methods (82)

No. Test object Methodology / Parameters Technique Reference document
Workplace Environment Testing Laboratory
1 Workplace environment - air Air sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction metals and their compounds, including – inhalable fraction – respirable fraction inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction asbestos – respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres silicon carbide fibrous – respirable fibres
Metoda dozymetrii indywidualnej - substancje nieorganiczne; Metoda stacjonarna PN-Z-04008-7:2002 +Az1:2004
2 Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002 +Az1:2004
3 Workplace environment - air Concentration of harmful dust agents - inhalable fraction:
Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Man-made mineral fibres, except refractory ceramic fibres Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Fibrous silicon carbide Range (0,10 – 42,46) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
4 Workplace environment - air Concentration of harmful dust agents - respirable fraction:
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,16 – 15,7) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
5 Workplace environment - air Carbon monoxide concentration
Range (2,3 – 232) mg/m3 Range (2 – 200) ppm
Electrochemical method GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r.
6 Workplace environment - air Exposure indices (calculated) GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r.
7 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (40 – 135) dB C-weighted peak sound pressure level Range (50 – 138) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 1 – punkt 9
8 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 1 – punkt 9
9 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (54 – 135) dB C-weighted peak sound pressure level Range (54 – 138) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 3 – punkt 11
10 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 3 – punkt 11
11 Workplace environment – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz
Range (54 – 142) dB
Direct measurement method PN-Z-01339:2020-12
12 Workplace environment – ultrasonic noise Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-Z-01339:2020-12
13 Workplace environment – air – air samples collected on filters Concentration/content of crystalline silica (quartz, cristobalite) – respirable fraction
Range (0,009 – 0,29) mg/m3 Range (0,006 – 0,2) mg w próbce
Fourier transform infrared spectrometry (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130
14 Workplace environment - indoor electric lighting Illuminance
Range (5 – 5 000) lx
Direct measurement method PN-83/E-04040.03
15 Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
16 Workplace environment - outdoor electric lighting Illuminance
Range (0,5 – 10 000) lx
Direct measurement method PN-83/E-04040.03
17 Workplace environment - outdoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
18 Workplace environment - outdoor electric lighting Ratio of maximum to minimum illuminance (calculated) PN-83/E-04040.03
19 Workplace environment - emergency lighting Illuminance
Range (0,5 – 500) lx
Direct measurement method PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B
20 Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated) Metody korekcji pomiaru (z obliczeń) PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B
21 Workplace environment - emergency lighting Illuminance
Range (0,5 – 500) lx
Direct measurement method PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5
22 Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5
23 Workplace environment - emergency lighting Uniformity of illuminance in the high-risk area (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5
24 Workplace environment - cold microclimate Air temperature
Range (-30 – 10) °C Black globe temperature Range (-30 – 15) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 5) m/s
Direct measurement method PN-EN ISO 11079:2008
25 Workplace environment - cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
26 Workplace environment - hot microclimate Air temperature
Range (10 – 50) °C Natural wet bulb temperature Range (10 – 40) °C Black globe temperature Range (10 – 50) °C
Direct measurement method PN-EN ISO 7243:2018-01
27 Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01
28 Workplace environment - moderate microclimate Air temperature
Range (10 – 30) °C Black globe temperature Range (10 – 40) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 5) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
29 Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
30 Workplace environment - energy expenditure Air flow
Range (10 – 60) dm3/min Air temperature Range (0 - 40) 0C
Direct measurement method GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r.
31 Workplace environment - energy expenditure Energy expenditure (calculated) GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r.
32 Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,03 – 25) m/s2
Direct measurement method PN-EN 14253+A1:2011
33 Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less, expressed as the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated) PN-EN 14253+A1:2011
34 Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,32 – 100) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
35 Workplace environment – hand-arm vibration Daily exposure ,expressed as the 8-hour energy-equivalent vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx , ahwy , ahwz)., Exposure lasting 30 minutes and less, expressed as the vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx , ahwy , ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
36 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 – 135) dB
Direct measurement method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
37 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
38 General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level Maximum A-weighted sound level A-weighted sound exposure level
Range (25 - 135) dB
Direct measurement method Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)
39 General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level for the reference time T expressed as LAeqD and LAeqN ( calculated) Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)
40 Electromagnetic field Magnetic flux density:
in the frequency range od 10 Hz do 400 kHz Range 0,1µT – 19 mT
Direct measurement method GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.
41 Electromagnetic field Electric field strength:
in the frequency range od 10 Hz do 400 kHz Range 1 V/m – 50 kV/m
Direct measurement method GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.
42 Electromagnetic field Magnetic field strength:
in the frequency range od 10 Hz do 400 kHz (calculated)
GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.
43 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density:
in the frequency range od 20 Hz do 50 Hz Range (0,1 – 12 500) µT
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)
Direct measurement method (simplified) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
44 Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength:
in the frequency range 20 Hz – 50 Hz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
Pracownia Badań Środowiska Pracy - Pracownia Terenowa
45 Workplace environment - air Air sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction metals and their compounds, including – inhalable fraction – respirable fraction inorganic substances, including – respirable fraction
Personal dosimetry method PN-Z-04008-7: 2002 +Az1:2004
46 Workplace environment - air Exposure index (calculated) PN-Z-04008-7: 2002 +Az1:2004
47 Workplace environment - air Concentration of harmful dust agents - inhalable fraction:
Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,11 – 42,46) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
48 Workplace environment - air Concentration of harmful dust agents - respirable fraction:
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,13 – 15,7) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
49 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (40 – 135) dB C-weighted peak sound pressure level Range (50 – 135) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
50 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
51 Workplace environment - indoor electric lighting Illuminance
Range (5 – 5 000) lx
Direct measurement method PN-83/E-04040.03
52 Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
53 Workplace environment - air Air sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction metals and their compounds, including – inhalable fraction – respirable fraction inorganic substances, including – respirable fraction
Personal dosimetry method PN-Z-04008-7: 2002 +Az1:2004
54 Workplace environment - air Exposure index (calculated) PN-Z-04008-7: 2002 +Az1:2004
55 Workplace environment - air Concentration of harmful dust agents - inhalable fraction:
Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,13 – 42,46) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
56 Workplace environment - air Concentration of harmful dust agents - respirable fraction:
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,14 – 15,7) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
57 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (40 – 135) dB C-weighted peak sound pressure level Range (50 – 135) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
58 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
59 Workplace environment - indoor electric lighting Illuminance
Range (5 – 5 000) lx
Direct measurement method PN-83/E-04040.03
60 Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
61 Workplace environment - cold microclimate Air temperature
Range (-30 – 10) °C Black globe temperature Range (-30 – 15) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 5) m/s
Direct measurement method PN-EN ISO 11079:2008
62 Workplace environment - cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
63 Workplace environment - hot microclimate Air temperature
Range (10 – 50) °C Natural wet bulb temperature Range (10 – 40) °C Black globe temperature Range (10 – 50) °C
Direct measurement method PN-EN ISO 7243:2018-01
64 Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01
65 Workplace environment - moderate microclimate Air temperature
Range (10 – 30) °C Black globe temperature Range (10 – 40) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 5) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
66 Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
67 Workplace environment - air Air sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction
Personal dosimetry method PN-Z-04008-7: 2002 +Az1:2004
68 Workplace environment - air Exposure index (calculated) PN-Z-04008-7: 2002 +Az1:2004
69 Workplace environment - air Concentration of harmful dust agents - inhalable fraction:
Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,11 – 42,46) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
70 Workplace environment - air Concentration of harmful dust agents - respirable fraction:
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,22 – 15,7) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
71 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level C-weighted peak sound level
Range (40 – 135) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
72 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
73 Workplace environment - indoor electric lighting Illuminance
Range (5 – 5 000) lx
Direct measurement method PN-83/E-04040.03
74 Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
75 Workplace environment - air Air sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction
Personal dosimetry method PN-Z-04008-7: 2002+Az1:2004
76 Workplace environment - air Exposure index (calculated) PN-Z-04008-7: 2002+Az1:2004
77 Workplace environment - air Concentration of harmful dust agents - inhalable fraction:
Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,10 – 42,46) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
78 Workplace environment - air Concentration of harmful dust agents - respirable fraction:
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,12 – 15,7) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
79 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (40 – 134) dB C-weighted peak sound pressure level Range (40 – 137) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
80 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
81 Workplace environment - indoor electric lighting Illuminance
Range (5 – 5 000) lx
Direct measurement method PN-83/E-04040.03
82 Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03

Reference standards (30)

GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r.
GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r.
GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5
PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2011 strategia 1 – punkt 9
PN-EN ISO 9612:2011 strategia 3 – punkt 11
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
PN-N-01307:1994
PN-Z-01339:2020-12
PN-Z-04008-7: 2002 +Az1:2004
PN-Z-04008-7: 2002+Az1:2004
PN-Z-04008-7:2002 +Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)