{"lab":{"_id":"69ad52a3de79e566650fb482","accr_number":"AB 896","country":"PL","accr_body":"PCA","address":"ul. Ptolemeusza 10, 62-800 Kalisz, LABORATORIUM BADAŃ ŚRODOWISKA PRACY, ul. Zielona 18","categories":["environment","construction","materials"],"city":"Kalisz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":82,"name":"GRUPA INTERLIS Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_896.pdf"],"scope_summary":"","search_text":"grupa interlis sp. z o.o. ul. ptolemeusza 10, 62-800 kalisz, laboratorium badań środowiska pracy, ul. zielona 18 environment materials other construction electronics automotive pharma metrology","status":"active","updated_at":"2026-03-08T14:51:47.421Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:31:38.769Z","email_confidence":"high","email_mx":true,"email_source":"https://www.interlis.pl/kontakt-laboratorium-kalisz/","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, hałas ultradźwiękowy, oświetlenie, mikroklimat, wydatek energetyczny, drgania, pole elektromagnetyczne) pole elektromagnetyczne","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, ultrasonic noise, lighting, microclimate, energy expenditure, vibration, electromagnetic field), electromagnetic field"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"}],"issue":{"no":"34","date":"26.05.2026"},"parse_date":"2026-08-18T01:31:38.769Z","parse_source":"agent-claude-code","map_coord":[51.725958,18.104702],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAŃ ŚRODOWISKA PRACY","address":"ul. Zielona 18","city":"Kalisz","postal":"62-800"},{"name":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","address":"ul. Lotnicza 1/3 lok. 3","city":"Kwidzyn","postal":"82-500"},{"name":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","address":"ul. Farbiarska 20/24 lok. 6","city":"Tomaszów Mazowiecki","postal":"97-200"},{"name":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","address":"Kobierniki 94","city":"Sandomierz","postal":"27-600"},{"name":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","address":"ul. Św. Jana 16","city":"Wodzisław Śląski","postal":"44-300"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/8c7e0dd4f13997bd5126b8fb55bd3204/AB%20896.pdf","has_en":true,"category_counts":{"environment":79,"construction":10,"materials":5,"other":3},"category_scores":{"environment":64.34,"construction":1.03,"materials":0.26,"other":0.09},"has_zh":true},"methods":[{"_id":"6a83b5faaf14b9c0e7b20ea6","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek powietrza do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna"},{"name":"azbest – włókna respirabilne"},{"name":"ogniotrwałe włókna ceramiczne"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"},{"name":"sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne"},{"name":"węglik krzemu włóknisty – włókna respirabilne"}],"technique":"Metoda dozymetrii indywidualnej - substancje nieorganiczne; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej - substancje nieorganiczne","Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek powietrza do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nazbest – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nwęglik krzemu włóknisty – włókna respirabilne\nMetoda dozymetrii indywidualnej - substancje nieorganiczne; Metoda stacjonarna","reference":"PN-Z-04008-7:2002 +Az1:2004","norm_bases":["PN-Z-04008-7:2002 +Az1:2004"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek powietrza do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nazbest – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nwęglik krzemu włóknisty – włókna respirabilne\nMetoda dozymetrii indywidualnej - substancje nieorganiczne; Metoda stacjonarna PN-Z-04008-7:2002 +Az1:2004 Srodowisko pracy - powietrze Pobieranie probek powietrza do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nazbest – wlokna respirabilne\nogniotrwale wlokna ceramiczne\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nsztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych – wlokna respirabilne\nweglik krzemu wloknisty – wlokna respirabilne\nMetoda dozymetrii indywidualnej - substancje nieorganiczne; Metoda stacjonarna PN-Z-04008-7:2002 +Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Air sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"},{"name":"inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction"},{"name":"asbestos – respirable fibres"},{"name":"refractory ceramic fibres"},{"name":"refractory ceramic fibres mixed with other man-made mineral fibres"},{"name":"man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres"},{"name":"silicon carbide fibrous – respirable fibres"}],"search_en":"Workplace environment - air Air sampling for the assessment of occupational exposure to: Workplace Environment Testing Laboratory dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction metals and their compounds, including – inhalable fraction – respirable fraction inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction asbestos – respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres silicon carbide fibrous – respirable fibres PN-Z-04008-7:2002 +Az1:2004","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 职业接触评估空气采样，针对： 工作场所环境检测实验室 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 － 胸腔性粉尘 石棉 — 呼吸性纤维 耐火陶瓷纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维 纤维状碳化硅 － 呼吸性纤维 PN-Z-04008-7:2002 +Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 － 胸腔性粉尘"},{"name":"石棉 — 呼吸性纤维"},{"name":"耐火陶瓷纤维"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"},{"name":"人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维"},{"name":"纤维状碳化硅 － 呼吸性纤维"}],"methodology_zh":"职业接触评估空气采样，针对："},{"_id":"6a83b5faaf14b9c0e7b20ea7","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 +Az1:2004","norm_bases":["PN-Z-04008-7:2002 +Az1:2004"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 +Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 +Az1:2004","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) Workplace Environment Testing Laboratory PN-Z-04008-7:2002 +Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） 工作场所环境检测实验室 PN-Z-04008-7:2002 +Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a83b5faaf14b9c0e7b20ea8","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Węglik krzemu włóknisty"},{"name":"Zakres","range":"(0,10 – 42,46) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nSztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nWęglik krzemu włóknisty\nZakres (0,10 – 42,46) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nSztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nWęglik krzemu włóknisty\nZakres (0,10 – 42,46) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nSztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nWeglik krzemu wloknisty\nZakres (0,10 – 42,46) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Man-made mineral fibres, except refractory ceramic fibres"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Fibrous silicon carbide"},{"name":"Range","range":"(0,10 – 42,46) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Workplace Environment Testing Laboratory Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Man-made mineral fibres, except refractory ceramic fibres Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Fibrous silicon carbide Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"人造矿物纤维，耐火陶瓷纤维除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"Węglik krzemu włóknisty"},{"name":"范围","range":"(0,10 – 42,46) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 工作场所环境检测实验室 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 人造矿物纤维，耐火陶瓷纤维除外 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a83b5faaf14b9c0e7b20ea9","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,16 – 15,7) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,16 – 15,7) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,16 – 15,7) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,16 – 15,7) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,16 – 15,7) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - respirable fraction: Gravimetric method Workplace Environment Testing Laboratory Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,16 – 15,7) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 工作场所环境检测实验室 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a83b5faaf14b9c0e7b20eaa","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,3 – 232) mg/m3"},{"name":"Zakres","range":"(2 – 200) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna","reference":"GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r.","norm_bases":["GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r. Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,3 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r.","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,3 – 232) mg/m3"},{"name":"Range","range":"(2 – 200) ppm"}],"search_en":"Workplace environment - air Carbon monoxide concentration Electrochemical method Workplace Environment Testing Laboratory Range Range GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(2,3 – 232) mg/m3"},{"name":"范围","range":"(2 – 200) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 工作场所环境检测实验室 范围 范围 GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"一氧化碳浓度"},{"_id":"6a83b5faaf14b9c0e7b20eab","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r.","norm_bases":["GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźniki narażenia (z obliczeń) GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r. Srodowisko pracy - powietrze Wskazniki narazenia (z obliczen) GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r.","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment - air Exposure indices (calculated) Workplace Environment Testing Laboratory GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r.","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 暴露指数（计算值） 工作场所环境检测实验室 GR-INT/PB-07 wydanie 5 z dnia 30.09.2025 r.","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"暴露指数（计算值）"},{"_id":"6a83b5faaf14b9c0e7b20eac","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(40 – 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(50 – 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 1 – punkt 9","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 strategia 1 – punkt 9"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 138) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 1 – punkt 9 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (40 – 135) dB\nSzczytowy poziom dzwieku C\nZakres (50 – 138) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 1 – punkt 9","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(40 – 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(50 – 138) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Workplace Environment Testing Laboratory Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 1 – punkt 9","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(40 – 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(50 – 138) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 工作场所环境检测实验室 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 1 – punkt 9","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a83b5faaf14b9c0e7b20ead","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 1 – punkt 9","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 strategia 1 – punkt 9"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 1 – punkt 9 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 1 – punkt 9","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: Workplace Environment Testing Laboratory an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 1 – punkt 9","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 工作场所环境检测实验室 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 1 – punkt 9","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a83b5faaf14b9c0e7b20eae","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(54 – 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(54 – 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (54 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (54 – 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 strategia 3 – punkt 11"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (54 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (54 – 138) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 3 – punkt 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (54 – 135) dB\nSzczytowy poziom dzwieku C\nZakres (54 – 138) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 3 – punkt 11","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(54 – 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(54 – 138) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Workplace Environment Testing Laboratory Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 3 – punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(54 – 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(54 – 138) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 工作场所环境检测实验室 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 3 – punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a83b5faaf14b9c0e7b20eaf","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 strategia 3 – punkt 11"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 3 – punkt 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 3 – punkt 11","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: Workplace Environment Testing Laboratory an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 3 – punkt 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 工作场所环境检测实验室 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 strategia 3 – punkt 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a83b5faaf14b9c0e7b20eb0","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz","parameters":[{"name":"Zakres","range":"(54 – 142) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (54 – 142) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (54 – 142) dB\nMetoda pomiarowa bezpośrednia PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Maksymalne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz\nZakres (54 – 142) dB\nMetoda pomiarowa bezposrednia PN-Z-01339:2020-12","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz","parameters_en":[{"name":"Range","range":"(54 – 142) dB"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Direct measurement method Workplace Environment Testing Laboratory Range PN-Z-01339:2020-12","technique_en":"Direct measurement method","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"范围","range":"(54 – 142) dB"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级 直接测量法 工作场所环境检测实验室 范围 PN-Z-01339:2020-12","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级"},{"_id":"6a83b5faaf14b9c0e7b20eb1","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:","parameters":[{"name":"8 - godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-Z-01339:2020-12","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to: Workplace Environment Testing Laboratory an 8-hour daily working time the average weekly working time (calculated) PN-Z-01339:2020-12","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"每日 8 小时工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照下列条件： 工作场所环境检测实验室 每日 8 小时工作时间 平均每周工作时间（计算值） PN-Z-01339:2020-12","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照下列条件："},{"_id":"6a83b5faaf14b9c0e7b20eb2","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(0,009 – 0,29) mg/m3"},{"name":"Zakres","range":"(0,006 – 0,2) mg w próbce"}],"technique":"Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,009 – 0,29) mg/m3\nZakres (0,006 – 0,2) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,009 – 0,29) mg/m3\nZakres (0,006 – 0,2) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Stezenie/zawartosc krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,009 – 0,29) mg/m3\nZakres (0,006 – 0,2) mg w probce\nMetoda spektrometrii w zakresie podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4 (74), str. 117-130","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Concentration/content of crystalline silica (quartz, cristobalite) – respirable fraction","parameters_en":[{"name":"Range","range":"(0,009 – 0,29) mg/m3"},{"name":"Range","range":"(0,006 – 0,2) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Concentration/content of crystalline silica (quartz, cristobalite) – respirable fraction Fourier transform infrared spectrometry (FT-IR) Workplace Environment Testing Laboratory Range Range Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,009 – 0,29) mg/m3"},{"name":"范围","range":"(0,006 – 0,2) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 傅里叶变换红外光谱法（FT-IR） 工作场所环境检测实验室 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a83b5faaf14b9c0e7b20eb3","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5 000) lx"}],"search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Workplace Environment Testing Laboratory Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5 000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 工作场所环境检测实验室 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a83b5faaf14b9c0e7b20eb4","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) Workplace Environment Testing Laboratory PN-83/E-04040.03","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） 工作场所环境检测实验室 PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a83b5faaf14b9c0e7b20eb5","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne na zewnątrz","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 10 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 10 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne na zewnątrz Natężenie oświetlenia\nZakres (0,5 – 10 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne na zewnatrz Natezenie oswietlenia\nZakres (0,5 – 10 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 10 000) lx"}],"search_en":"Workplace environment - outdoor electric lighting Illuminance Direct measurement method Workplace Environment Testing Laboratory Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - outdoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 10 000) lx"}],"search_zh":"工作场所环境 — 室外电气照明 照度 直接测量法 工作场所环境检测实验室 范围 PN-83/E-04040.03","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 室外电气照明"},{"_id":"6a83b5faaf14b9c0e7b20eb6","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne na zewnątrz","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne na zewnątrz Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne na zewnatrz Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - outdoor electric lighting Illuminance uniformity (calculated) Workplace Environment Testing Laboratory PN-83/E-04040.03","test_object_en":"Workplace environment - outdoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室外电气照明 照度均匀度（计算值） 工作场所环境检测实验室 PN-83/E-04040.03","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 室外电气照明"},{"_id":"6a83b5faaf14b9c0e7b20eb7","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne na zewnątrz","methodology":"Stosunek maksymalnego do minimalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek maksymalnego do minimalnego natężenia oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne na zewnątrz Stosunek maksymalnego do minimalnego natężenia oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne na zewnatrz Stosunek maksymalnego do minimalnego natezenia oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Ratio of maximum to minimum illuminance (calculated)","search_en":"Workplace environment - outdoor electric lighting Ratio of maximum to minimum illuminance (calculated) Workplace Environment Testing Laboratory PN-83/E-04040.03","test_object_en":"Workplace environment - outdoor electric lighting","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作场所环境 — 室外电气照明 最大照度与最小照度之比（由计算得出） 工作场所环境检测实验室 PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室外电气照明","methodology_zh":"最大照度与最小照度之比（由计算得出）"},{"_id":"6a83b5faaf14b9c0e7b20eb8","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B Srodowisko pracy - oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2025-05 z wylaczeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Zalacznik B","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 500) lx"}],"search_en":"Workplace environment - emergency lighting Illuminance Direct measurement method Workplace Environment Testing Laboratory Range PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 500) lx"}],"search_zh":"工作场所环境 — 应急照明 照度 直接测量法 工作场所环境检测实验室 范围 PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a83b5faaf14b9c0e7b20eb9","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":"Metody korekcji pomiaru (z obliczeń)","techniques":["Metody korekcji pomiaru (z obliczeń)"],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)\nMetody korekcji pomiaru (z obliczeń)","reference":"PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)\nMetody korekcji pomiaru (z obliczeń) PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B Srodowisko pracy - oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen)\nMetody korekcji pomiaru (z obliczen) PN-EN 1838:2025-05 z wylaczeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Zalacznik B","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated) Workplace Environment Testing Laboratory PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B","test_object_en":"Workplace environment - emergency lighting","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作场所环境 — 应急照明 最小与最大照度之比（计算值） 工作场所环境检测实验室 PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3 - 5.1.9, 5.2.3 - 5.2.7; 5.3.4 - 5.3.8; 5.4.2; 6; 7; + Załącznik B","methodology_zh":"最小与最大照度之比（计算值）","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a83b5faaf14b9c0e7b20eba","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5 Srodowisko pracy - oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 500) lx"}],"search_en":"Workplace environment - emergency lighting Illuminance Direct measurement method Workplace Environment Testing Laboratory Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 500) lx"}],"search_zh":"工作场所环境 — 应急照明 照度 直接测量法 工作场所环境检测实验室 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a83b5faaf14b9c0e7b20ebb","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5 Srodowisko pracy - oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated) Workplace Environment Testing Laboratory PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5","test_object_en":"Workplace environment - emergency lighting","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作场所环境 — 应急照明 最小与最大照度之比（计算值） 工作场所环境检测实验室 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5","methodology_zh":"最小与最大照度之比（计算值）","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a83b5faaf14b9c0e7b20ebc","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Równomierność natężenia oświetlenia w strefie wysokiego ryzyka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność natężenia oświetlenia w strefie wysokiego ryzyka (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Równomierność natężenia oświetlenia w strefie wysokiego ryzyka (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5 Srodowisko pracy - oswietlenie awaryjne Rownomiernosc natezenia oswietlenia w strefie wysokiego ryzyka (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Uniformity of illuminance in the high-risk area (calculated)","search_en":"Workplace environment - emergency lighting Uniformity of illuminance in the high-risk area (calculated) Workplace Environment Testing Laboratory PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5","test_object_en":"Workplace environment - emergency lighting","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作场所环境 — 应急照明 工作场所环境检测实验室 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3 – 4.2.7; 4.3.3 – 4.3.7; 4.4.3 – 4.4.7; 4.5 i 5","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a83b5faaf14b9c0e7b20ebd","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 – 15) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 15) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 15) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 15) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30 – 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30 – 15) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5) m/s"}],"search_en":"Workplace environment - cold microclimate Air temperature Direct measurement method Workplace Environment Testing Laboratory Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment - cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 – 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 – 15) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 工作场所环境检测实验室 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a83b5faaf14b9c0e7b20ebe","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment - cold microclimate IREQmin index, IREQneutral index, twc index (calculated) Workplace Environment Testing Laboratory PN-EN ISO 11079:2008","test_object_en":"Workplace environment - cold microclimate","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） 工作场所环境检测实验室 PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）"},{"_id":"6a83b5faaf14b9c0e7b20ebf","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 – 40) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 50) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 50) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 – 40) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 50) °C"}],"search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method Workplace Environment Testing Laboratory Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 50) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 – 40) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 50) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 工作场所环境检测实验室 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83b5faaf14b9c0e7b20ec0","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) Workplace Environment Testing Laboratory PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment - hot microclimate","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） 工作场所环境检测实验室 PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83b5faaf14b9c0e7b20ec1","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 40) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 40) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5) m/s"}],"search_en":"Workplace environment - moderate microclimate Air temperature Direct measurement method Workplace Environment Testing Laboratory Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 40) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 工作场所环境检测实验室 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83b5faaf14b9c0e7b20ec2","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment - moderate microclimate PMV index, PPD index (calculated) Workplace Environment Testing Laboratory PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_en":"Workplace environment - moderate microclimate","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） 工作场所环境检测实验室 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83b5faaf14b9c0e7b20ec3","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","methodology":"Przepływ powietrza","parameters":[{"name":"Zakres","range":"(10 – 60) dm3/min"},{"name":"Temperatura powietrza"},{"name":"Zakres","range":"(0 - 40) 0C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Przepływ powietrza\nZakres:\nZakres (10 – 60) dm3/min\nTemperatura powietrza\nZakres (0 - 40) 0C\nMetoda pomiarowa bezpośrednia","reference":"GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r.","norm_bases":["GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - wydatek energetyczny Przepływ powietrza\nZakres:\nZakres (10 – 60) dm3/min\nTemperatura powietrza\nZakres (0 - 40) 0C\nMetoda pomiarowa bezpośrednia GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r. Srodowisko pracy - wydatek energetyczny Przeplyw powietrza\nZakres:\nZakres (10 – 60) dm3/min\nTemperatura powietrza\nZakres (0 - 40) 0C\nMetoda pomiarowa bezposrednia GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r.","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Air flow","parameters_en":[{"name":"Range","range":"(10 – 60) dm3/min"},{"name":"Air temperature"},{"name":"Range","range":"(0 - 40) 0C"}],"search_en":"Workplace environment - energy expenditure Air flow Direct measurement method Workplace Environment Testing Laboratory Range Air temperature Range GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - energy expenditure","parameters_zh":[{"name":"范围","range":"(10 – 60) dm3/min"},{"name":"空气温度"},{"name":"范围","range":"(0 - 40) 0C"}],"search_zh":"工作场所环境 — 能量消耗 空气流量 直接测量法 工作场所环境检测实验室 范围 空气温度 范围 GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r.","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 能量消耗","methodology_zh":"空气流量"},{"_id":"6a83b5faaf14b9c0e7b20ec4","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","methodology":"Wydatek energetyczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r.","norm_bases":["GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczeń) GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r. Srodowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczen) GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r.","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Energy expenditure (calculated)","search_en":"Workplace environment - energy expenditure Energy expenditure (calculated) Workplace Environment Testing Laboratory GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r.","test_object_en":"Workplace environment - energy expenditure","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值） 工作场所环境检测实验室 GR-INT/PB-06 wydanie 3 z dnia 30.09.2025 r.","methodology_zh":"能量消耗（计算值）","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a83b5faaf14b9c0e7b20ec5","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,03 – 25) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 25) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 25) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,03 – 25) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,03 – 25) m/s2"}],"search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Workplace Environment Testing Laboratory Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,03 – 25) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 工作场所环境检测实验室 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a83b5faaf14b9c0e7b20ec6","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8 godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less, expressed as the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less, expressed as the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated) Workplace Environment Testing Laboratory PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 工作场所环境检测实验室 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a83b5faaf14b9c0e7b20ec7","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,32 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,32 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,32 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,32 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,32 – 100) m/s2"}],"search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Workplace Environment Testing Laboratory Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,32 – 100) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 工作场所环境检测实验室 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a83b5faaf14b9c0e7b20ec8","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna ,wyrażona w postaci równoważnej energetycznie dla8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx , ahwy , ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx , ahwy , ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna ,wyrażona w postaci równoważnej energetycznie dla8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx , ahwy , ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx , ahwy , ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna ,wyrażona w postaci równoważnej energetycznie dla8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx , ahwy , ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx , ahwy , ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna ,wyrazona w postaci rownowaznej energetycznie dla8 godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx , ahwy , ahwz)., Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx , ahwy , ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Daily exposure ,expressed as the 8-hour energy-equivalent vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx , ahwy , ahwz)., Exposure lasting 30 minutes and less, expressed as the vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx , ahwy , ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration Daily exposure ,expressed as the 8-hour energy-equivalent vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx , ahwy , ahwz)., Exposure lasting 30 minutes and less, expressed as the vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx , ahwy , ahwz) (calculated) Workplace Environment Testing Laboratory PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration","search_zh":"工作场所环境 — 手传振动 工作场所环境检测实验室 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a83b5faaf14b9c0e7b20ec9","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 135) dB"}],"technique":"Metoda bezpośredniego pomiaru","techniques":["Metoda bezpośredniego pomiaru"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 – 135) dB\nMetoda bezpośredniego pomiaru","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 – 135) dB\nMetoda bezpośredniego pomiaru Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 – 135) dB\nMetoda bezposredniego pomiaru Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 – 135) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Workplace Environment Testing Laboratory Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 – 135) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 工作场所环境检测实验室 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","lab_section_zh":"工作场所环境检测实验室","technique_zh":"直接测量法"},{"_id":"6a83b5faaf14b9c0e7b20eca","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Workplace Environment Testing Laboratory Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 工作场所环境检测实验室 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a83b5faaf14b9c0e7b20ecb","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 - 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25 - 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","norm_bases":["Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25 - 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) Srodowisko ogolne − halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (25 - 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(25 - 135) dB"}],"search_en":"General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level Maximum A-weighted sound level A-weighted sound exposure level Direct measurement method Workplace Environment Testing Laboratory Range Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","technique_en":"Direct measurement method","test_object_en":"General environment − impulse noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级 A 计权最大声级 A 计权暴露声级","parameters_zh":[{"name":"范围","range":"(25 - 135) dB"}],"search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 A 计权等效声级 A 计权最大声级 A 计权暴露声级 直接测量法 工作场所环境检测实验室 范围 Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a83b5faaf14b9c0e7b20ecc","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony LAeqD i LAeqN ( z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony LAeqD i LAeqN ( z obliczeń)","reference":"Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","norm_bases":["Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony LAeqD i LAeqN ( z obliczeń) Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) Srodowisko ogolne − halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony LAeqD i LAeqN ( z obliczen) Zalacznik nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"A-weighted equivalent sound level for the reference time T expressed as LAeqD and LAeqN ( calculated)","search_en":"General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level for the reference time T expressed as LAeqD and LAeqN ( calculated) Workplace Environment Testing Laboratory Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","test_object_en":"General environment − impulse noise from installations, equipment and industrial plants","lab_section_zh":"工作场所环境检测实验室","search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 工作场所环境检测实验室 Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a83b5faaf14b9c0e7b20ecd","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Pole elektromagnetyczne","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości","range":"od 10 Hz do 400 kHz"},{"name":"Zakres","range":"0,1µT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 0,1µT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.","norm_bases":["GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pole elektromagnetyczne Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 0,1µT – 19 mT\nMetoda pomiarowa bezpośrednia GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r. Pole elektromagnetyczne Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres 0,1µT – 19 mT\nMetoda pomiarowa bezposrednia GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range","range":"od 10 Hz do 400 kHz"},{"name":"Range","range":"0,1µT – 19 mT"}],"search_en":"Electromagnetic field Magnetic flux density: Direct measurement method Workplace Environment Testing Laboratory in the frequency range Range GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.","technique_en":"Direct measurement method","test_object_en":"Electromagnetic field","parameters_zh":[{"name":"频率范围","range":"od 10 Hz do 400 kHz"},{"name":"范围","range":"0,1µT – 19 mT"}],"search_zh":"电磁场 磁感应强度： 直接测量法 工作场所环境检测实验室 频率范围 范围 GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"磁感应强度：","test_object_zh":"电磁场"},{"_id":"6a83b5faaf14b9c0e7b20ece","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Pole elektromagnetyczne","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 10 Hz do 400 kHz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia","reference":"GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.","norm_bases":["GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pole elektromagnetyczne Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r. Pole elektromagnetyczne Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezposrednia GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 10 Hz do 400 kHz"},{"name":"Range","range":"1 V/m – 50 kV/m"}],"search_en":"Electromagnetic field Electric field strength: Direct measurement method Workplace Environment Testing Laboratory in the frequency range Range GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.","technique_en":"Direct measurement method","test_object_en":"Electromagnetic field","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 10 Hz do 400 kHz"},{"name":"范围","range":"1 V/m – 50 kV/m"}],"search_zh":"电磁场 电场强度： 直接测量法 工作场所环境检测实验室 频率范围 范围 GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"电磁场"},{"_id":"6a83b5faaf14b9c0e7b20ecf","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Pole elektromagnetyczne","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 10 Hz do 400 kHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\n(z obliczeń)","reference":"GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.","norm_bases":["GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pole elektromagnetyczne Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\n(z obliczeń) GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r. Pole elektromagnetyczne Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\n(z obliczen) GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 10 Hz do 400 kHz"},{"name":"(calculated)"}],"search_en":"Electromagnetic field Magnetic field strength: Workplace Environment Testing Laboratory in the frequency range (calculated) GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.","test_object_en":"Electromagnetic field","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 10 Hz do 400 kHz"},{"name":"（计算得出）"}],"search_zh":"电磁场 磁场强度： 工作场所环境检测实验室 频率范围 （计算得出） GR-INT/PB-09 wydanie 5 z dnia 27.03.2023 r.","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"电磁场"},{"_id":"6a83b5faaf14b9c0e7b20ed0","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości","range":"od 20 Hz do 50 Hz"},{"name":"Zakres","range":"(0,1 – 12 500) µT"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 20 Hz do 50 Hz\nZakres (0,1 – 12 500) µT\nMetoda pomiarowa bezpośrednia (uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 20 Hz do 50 Hz\nZakres (0,1 – 12 500) µT\nMetoda pomiarowa bezpośrednia (uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci od 20 Hz do 50 Hz\nZakres (0,1 – 12 500) µT\nMetoda pomiarowa bezposrednia (uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 – 180","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range","range":"od 20 Hz do 50 Hz"},{"name":"Range","range":"(0,1 – 12 500) µT"}],"search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density: Direct measurement method (simplified) Workplace Environment Testing Laboratory in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","technique_en":"Direct measurement method (simplified)","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices","parameters_zh":[{"name":"频率范围","range":"od 20 Hz do 50 Hz"},{"name":"范围","range":"(0,1 – 12 500) µT"}],"search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 磁感应强度： 直接测量法（简化） 工作场所环境检测实验室 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"磁感应强度：","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场","technique_zh":"直接测量法（简化）"},{"_id":"6a83b5faaf14b9c0e7b20ed1","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"20 Hz – 50 Hz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 20 Hz – 50 Hz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 20 Hz – 50 Hz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci 20 Hz – 50 Hz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 – 180","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"20 Hz – 50 Hz"},{"name":"(calculated)"}],"search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength: Workplace Environment Testing Laboratory in the frequency range (calculated) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"20 Hz – 50 Hz"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 磁场强度： 工作场所环境检测实验室 频率范围 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场"},{"_id":"6a83b5faaf14b9c0e7b20ed2","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek powietrza do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje nieorganiczne, w tym – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek powietrza do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje nieorganiczne, w tym – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7: 2002 +Az1:2004","norm_bases":["PN-Z-04008-7: 2002 +Az1:2004"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek powietrza do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje nieorganiczne, w tym – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7: 2002 +Az1:2004 Srodowisko pracy - powietrze Pobieranie probek powietrza do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje nieorganiczne, w tym – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7: 2002 +Az1:2004","categories":["materials","environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"},{"name":"inorganic substances, including – respirable fraction"}],"search_en":"Workplace environment - air Air sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction metals and their compounds, including – inhalable fraction – respirable fraction inorganic substances, including – respirable fraction PN-Z-04008-7: 2002 +Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 职业接触评估空气采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 无机物质，其中包括 － 呼吸性粉尘 PN-Z-04008-7: 2002 +Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"无机物质，其中包括 － 呼吸性粉尘"}],"methodology_zh":"职业接触评估空气采样，针对："},{"_id":"6a83b5faaf14b9c0e7b20ed3","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7: 2002 +Az1:2004","norm_bases":["PN-Z-04008-7: 2002 +Az1:2004"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7: 2002 +Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7: 2002 +Az1:2004","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7: 2002 +Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7: 2002 +Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b5faaf14b9c0e7b20ed4","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,11 – 42,46) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,11 – 42,46) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,11 – 42,46) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,11 – 42,46) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,11 – 42,46) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,11 – 42,46) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a83b5faaf14b9c0e7b20ed5","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,13 – 15,7) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,13 – 15,7) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,13 – 15,7) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nWegiel (kamienny, brunatny)\nZakres (0,13 – 15,7) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,13 – 15,7) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - respirable fraction: Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,13 – 15,7) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a83b5faaf14b9c0e7b20ed6","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(40 – 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(50 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 135) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (40 – 135) dB\nSzczytowy poziom dzwieku C\nZakres (50 – 135) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(40 – 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(50 – 135) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(40 – 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(50 – 135) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b5faaf14b9c0e7b20ed7","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b5faaf14b9c0e7b20ed8","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5 000) lx"}],"search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5 000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b5faaf14b9c0e7b20ed9","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b5faaf14b9c0e7b20eda","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek powietrza do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje nieorganiczne, w tym – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek powietrza do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje nieorganiczne, w tym – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7: 2002 +Az1:2004","norm_bases":["PN-Z-04008-7: 2002 +Az1:2004"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek powietrza do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje nieorganiczne, w tym – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7: 2002 +Az1:2004 Srodowisko pracy - powietrze Pobieranie probek powietrza do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nsubstancje nieorganiczne, w tym – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7: 2002 +Az1:2004","categories":["materials","environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"},{"name":"inorganic substances, including – respirable fraction"}],"search_en":"Workplace environment - air Air sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction metals and their compounds, including – inhalable fraction – respirable fraction inorganic substances, including – respirable fraction PN-Z-04008-7: 2002 +Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 职业接触评估空气采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 无机物质，其中包括 － 呼吸性粉尘 PN-Z-04008-7: 2002 +Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"无机物质，其中包括 － 呼吸性粉尘"}],"methodology_zh":"职业接触评估空气采样，针对："},{"_id":"6a83b5faaf14b9c0e7b20edb","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7: 2002 +Az1:2004","norm_bases":["PN-Z-04008-7: 2002 +Az1:2004"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7: 2002 +Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7: 2002 +Az1:2004","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7: 2002 +Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7: 2002 +Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b5faaf14b9c0e7b20edc","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,13 – 42,46) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,13 – 42,46) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,13 – 42,46) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,13 – 42,46) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,13 – 42,46) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,13 – 42,46) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a83b5faaf14b9c0e7b20edd","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,14 – 15,7) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,14 – 15,7) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,14 – 15,7) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nWegiel (kamienny, brunatny)\nZakres (0,14 – 15,7) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,14 – 15,7) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - respirable fraction: Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,14 – 15,7) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a83b5faaf14b9c0e7b20ede","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(40 – 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(50 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 135) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (40 – 135) dB\nSzczytowy poziom dzwieku C\nZakres (50 – 135) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(40 – 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(50 – 135) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(40 – 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(50 – 135) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b5faaf14b9c0e7b20edf","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b5faaf14b9c0e7b20ee0","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5 000) lx"}],"search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5 000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b5faaf14b9c0e7b20ee1","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b5faaf14b9c0e7b20ee2","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 – 15) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 15) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 15) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 15) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30 – 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30 – 15) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5) m/s"}],"search_en":"Workplace environment - cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment - cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 – 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 – 15) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a83b5faaf14b9c0e7b20ee3","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment - cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008","test_object_en":"Workplace environment - cold microclimate","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）"},{"_id":"6a83b5faaf14b9c0e7b20ee4","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 – 40) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 50) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 50) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 – 40) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 50) °C"}],"search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 50) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 – 40) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 50) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83b5faaf14b9c0e7b20ee5","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83b5faaf14b9c0e7b20ee6","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 40) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 40) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5) m/s"}],"search_en":"Workplace environment - moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 40) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83b5faaf14b9c0e7b20ee7","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83b5faaf14b9c0e7b20ee8","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek powietrza do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym – frakcja respirabilna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek powietrza do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7: 2002 +Az1:2004","norm_bases":["PN-Z-04008-7: 2002 +Az1:2004"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek powietrza do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7: 2002 +Az1:2004 Srodowisko pracy - powietrze Pobieranie probek powietrza do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja respirabilna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7: 2002 +Az1:2004","categories":["materials","environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"},{"name":"inorganic substances, including – respirable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"}],"search_en":"Workplace environment - air Air sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction PN-Z-04008-7: 2002 +Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 职业接触评估空气采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 无机物质，其中包括 － 呼吸性粉尘 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 PN-Z-04008-7: 2002 +Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"无机物质，其中包括 － 呼吸性粉尘"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"}],"methodology_zh":"职业接触评估空气采样，针对："},{"_id":"6a83b5faaf14b9c0e7b20ee9","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7: 2002 +Az1:2004","norm_bases":["PN-Z-04008-7: 2002 +Az1:2004"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7: 2002 +Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7: 2002 +Az1:2004","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7: 2002 +Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7: 2002 +Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b5faaf14b9c0e7b20eea","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,11 – 42,46) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,11 – 42,46) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,11 – 42,46) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,11 – 42,46) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,11 – 42,46) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,11 – 42,46) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a83b5faaf14b9c0e7b20eeb","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,22 – 15,7) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,22 – 15,7) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,22 – 15,7) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nWegiel (kamienny, brunatny)\nZakres (0,22 – 15,7) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,22 – 15,7) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - respirable fraction: Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,22 – 15,7) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a83b5faaf14b9c0e7b20eec","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C","parameters":[{"name":"Zakres","range":"(40 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C\nZakres (40 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C\nZakres (40 – 135) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Szczytowy poziom dzwieku C\nZakres (40 – 135) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level C-weighted peak sound level","parameters_en":[{"name":"Range","range":"(40 – 135) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level C-weighted peak sound level Direct measurement method Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","parameters_zh":[{"name":"范围","range":"(40 – 135) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 C 计权峰值声级 直接测量法 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","methodology_zh":"A 计权等效声级 A 计权最大声级 C 计权峰值声级"},{"_id":"6a83b5faaf14b9c0e7b20eed","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b5faaf14b9c0e7b20eee","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5 000) lx"}],"search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5 000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b5faaf14b9c0e7b20eef","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b5faaf14b9c0e7b20ef0","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek powietrza do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym – frakcja respirabilna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek powietrza do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7: 2002+Az1:2004","norm_bases":["PN-Z-04008-7: 2002+Az1:2004"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek powietrza do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7: 2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek powietrza do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja respirabilna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7: 2002+Az1:2004","categories":["materials","environment"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"},{"name":"inorganic substances, including – respirable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"}],"search_en":"Workplace environment - air Air sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction PN-Z-04008-7: 2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 职业接触评估空气采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 无机物质，其中包括 － 呼吸性粉尘 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 PN-Z-04008-7: 2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"无机物质，其中包括 － 呼吸性粉尘"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"}],"methodology_zh":"职业接触评估空气采样，针对："},{"_id":"6a83b5faaf14b9c0e7b20ef1","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7: 2002+Az1:2004","norm_bases":["PN-Z-04008-7: 2002+Az1:2004"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7: 2002+Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7: 2002+Az1:2004","categories":["environment"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7: 2002+Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7: 2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b5faaf14b9c0e7b20ef2","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,10 – 42,46) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,10 – 42,46) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,10 – 42,46) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,10 – 42,46) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,10 – 42,46) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,10 – 42,46) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a83b5faaf14b9c0e7b20ef3","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,12 – 15,7) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,12 – 15,7) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,12 – 15,7) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nWegiel (kamienny, brunatny)\nZakres (0,12 – 15,7) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,12 – 15,7) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - respirable fraction: Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,12 – 15,7) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a83b5faaf14b9c0e7b20ef4","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(40 – 134) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(40 – 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 134) dB\nSzczytowy poziom dźwięku C\nZakres (40 – 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 134) dB\nSzczytowy poziom dźwięku C\nZakres (40 – 137) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (40 – 134) dB\nSzczytowy poziom dzwieku C\nZakres (40 – 137) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(40 – 134) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(40 – 137) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(40 – 134) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(40 – 137) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b5faaf14b9c0e7b20ef5","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b5faaf14b9c0e7b20ef6","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5 000) lx"}],"search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5 000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b5faaf14b9c0e7b20ef7","lab_id":"69ad52a3de79e566650fb482","country":"PL","accr_number":"AB 896","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Pracownia Badań Środowiska Pracy - Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明"}],"has_pdf":true}