🇵🇱 TESMO Sp. z o. o. PL
EnvironmentMaterials & polymers
TESMO Sp. z o. o. is a laboratory accredited by PCA under number AB 872 (Warszawa, Poland). Its accreditation scope covers 81 test methods in the following areas: Environment, Materials & polymers. Test objects include: Waste gases, Automated Measuring Systems (AMS), General environment – noise from installations, equipment and indus…, Waste gas dedusting equipment. Most frequently used techniques: Non-dispersive infrared spectrometry (NDIR), Aspiration method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 872
- Methods in scope: 81
- Types of test objects: 4
- Techniques used: 18
- City: Warszawa, Poland
- Accreditation number
- AB 872
- Accreditation body
- PCA
- Address
- ul. Adama Mickiewicza 35A, 05-816 Michałowice, LABORATORIUM, ul. Rzeczna 10, 03-794 Warszawa
- City
- Warszawa, Poland
What this laboratory tests (4)
- Waste gases — 58 methods
- Automated Measuring Systems (AMS) — 19 methods
- General environment – noise from installations, equipment and industrial plants — 2 methods
- Waste gas dedusting equipment — 2 methods
Analytical techniques used (18)
- Non-dispersive infrared spectrometry (NDIR) — 6 methods
- Aspiration method — 5 methods
- Gravimetric method — 4 methods
- Spectrophotometric method — 4 methods
- Adsorption method — 2 methods
- Chemiluminescence method (CLD) — 2 methods
- Continuous measurement with flame ionization detection (FID) — 2 methods
- Ion-selective electrode method — 2 methods
- Paramagnetic method (PMD) — 2 methods
- Thoron method — 2 methods
- Anemometric method — 1 method
- Aspiration method using absorbing solutions and membrane filters — 1 method
- Direct measurement method — 1 method
- Electrochemical method — 1 method
- Filtration and condensation method — 1 method
- and 3 more
Accreditation scope — test methods (81)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa | Stagnation pressure method | PN-Z-04030-7:1994 | |
| 2 | Waste gases | Gas volume flow rate. Velocity. Range (1,0 – 30) m/s |
Anemometric method | PN-EN 16911:2013-07 | |
| 3 | Waste gases | Dust sampling for testing of dust concentration | PN-Z-04030-7:1994 | ||
| 4 | Waste gases | Dust concentration Range (0,001 – 100) g/m3 |
Gravimetric method | PN-Z-04030-7:1994 | |
| 5 | Waste gases | Dust emission (calculated) | PN-Z-04030-7:1994 | ||
| 6 | Waste gases | Dust sampling for testing of dust concentration | PN-EN 13284-1:2018-02 | ||
| 7 | Waste gases | Dust concentration Range (1,0 – 50) g/m3 |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 8 | Waste gases | Dust emission (calculated) | PN-EN 13284-1:2018-02 | ||
| 9 | Waste gases | SO2 concentration Range (4,75 – 2500) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-ISO 10396:2001 | |
| 10 | Waste gases | SO2 emission (calculated) | PN-ISO 10396:2001 | ||
| 11 | Waste gases | NO, NOx concentration NO (0,84 - 654) mg/m3 NOx (1,29 - 1000) mg/m3 |
Chemiluminescence method (CLD) | PN-ISO 10396:2001 | PN-EN 14792:2017-04 | |
| 12 | Waste gases | Emission of NO and NOx (NO and NO2 calculated as NO2) (calculated) | PN-ISO 10396:2001 | PN-EN 14792:2017-04 | ||
| 13 | Waste gases | Sampling for determination of SO2 concentration | PN-EN 14791:2017-04 | ||
| 14 | Waste gases | SO2 concentration Range (5,0 – 2000) mg/m3 |
Thoron method | PN-EN 14791:2017-04 | |
| 15 | Waste gases | SO2 emission (calculated) | PN-EN 14791:2017-04 | ||
| 16 | Waste gases | Oxygen concentration Range (0,2 – 21) % |
Electrochemical method | PN-ISO 10396:2001 | |
| 17 | Waste gases | Oxygen concentration Range (1 – 21) % |
Paramagnetic method (PMD) | PN-EN 14789:2017-04 | |
| 18 | Waste gases | CO concentration Range (2,40 – 740) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017-04 | PN-ISO 10396:2001 | |
| 19 | Waste gases | CO emission (calculated) | PN-EN 15058:2017-04 | PN-ISO 10396:2001 | ||
| 20 | Waste gases | Carbon dioxide concentration Range (0,2 – 25) % |
Non-dispersive infrared spectrometry (NDIR) | PN-ISO 10396:2001 | |
| 21 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (1,0 – 1000) mg/m3 |
Continuous measurement with flame ionization detection (FID) | PN-EN 12619:2013-05 | |
| 22 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) | PN-EN 12619:2013-05 | ||
| 23 | Waste gases | Water vapour concentration (H2O) Range (4,0 – 26) % obj. |
Adsorption method | PN-EN 14790:2017-04 | |
| 24 | Waste gases | Sampling for determination of the concentration of PCDD/PCDFs | Filtration and condensation method | PN-EN 1948-1:2006 | |
| 25 | Waste gases | Emission of PCDD/PCDFs compounds (calculated) | PN-EN 1948-1:2006 | ||
| 26 | Waste gases | Sampling for determination of the concentration of individual gaseous organic compounds | PN-EN 13649:2005 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r. | ||
| 27 | Waste gases | Emission of individual gaseous organic compounds (calculated) | PN-EN 13649:2005 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r. | ||
| 28 | Waste gases | Sampling for determination of hydrogen chloride concentrations | Aspiration method | PN-EN 1911:2011 | |
| 29 | Waste gases | HCl concentration Range (0,5 – 500) mg/m3 |
Spectrophotometric method | PN-EN 1911:2011 | |
| 30 | Waste gases | HCl emission (calculated) | PN-EN 1911:2011 | ||
| 31 | Waste gases | Sampling for determination of total mercury concentration | Filtration-aspiration method | PN-EN 13211+AC:2006 | |
| 32 | Waste gases | Total mercury emission (calculated) | PN-EN 13211+AC:2006 | ||
| 33 | Waste gases | Sampling for determination of concentrations of organic compounds | PN-Z-04008-4:1999 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r. | ||
| 34 | Waste gases | Emission of organic compounds (calculated) | PN-Z-04008-4:1999 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r. | ||
| 35 | Waste gases | Sampling for testing of hydrogen fluoride concentrations | Aspiration method | ISO 15713:2006 | |
| 36 | Waste gases | Gaseous fluoride concentration Range (0,1 – 200) mg/m3 |
Ion-selective electrode method | ISO 15713:2006 | |
| 37 | Waste gases | HF emission (calculated) | ISO 15713:2006 | ||
| 38 | Waste gases | Sampling for determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) | PN-EN 14385:2005 | ||
| 39 | Waste gases | Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) | PN-EN 14385:2005 | ||
| 40 | Automated Measuring Systems (AMS) | AMS calibration (QAL2) for: dust, CO2 , organic substances in the form of gases and vapours expressed as total gaseous organic carbon, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg | PN-EN 14181:2015-02 | ||
| 41 | Automated Measuring Systems (AMS) | Annual surveillance tests (AST) for: dust, CO2 , organic substances in the form of gases and vapours expressed as total gaseous organic carbon, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg | PN-EN 14181:2015-02 | ||
| 42 | Automated Measuring Systems (AMS) | Dust concentration Range (0,001 – 100) g/m3 |
Gravimetric method | PN-Z-04030-7:1994 | |
| 43 | Automated Measuring Systems (AMS) | CO2 concentration Range (0,2 – 25) % |
NDIR method | PN-ISO 10396:2001 | |
| 44 | Automated Measuring Systems (AMS) | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (1,0 – 1000) mg/m3 |
Continuous measurement with flame ionization detection (FID) | PN-EN 12619:2013-05 | |
| 45 | Automated Measuring Systems (AMS) | NO, NOx concentration NO (0,84 – 654) mg/m3 NOX (1,29 – 1000) mg/m3 |
Chemiluminescence method (CLD) | PN-EN 14792:2017-04 | |
| 46 | Automated Measuring Systems (AMS) | SO2 concentration Range (5,0 – 2000) mg/m3 |
Thoron method | PN-EN 14791:2017-04 | |
| 47 | Automated Measuring Systems (AMS) | CO concentration Range (2,4 – 740) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2017-04 | |
| 48 | Automated Measuring Systems (AMS) | O2 concentration Range (1,0 – 21) % |
Paramagnetic method (PMD) | PN-EN 14789:2017-04 | |
| 49 | Automated Measuring Systems (AMS) | Water vapour concentration (H2O) Range (4,0 – 26) % obj. |
Adsorption method | PN-EN 14790:2017-04 | |
| 50 | Automated Measuring Systems (AMS) | Sampling for testing of hydrogen chloride concentrations | Aspiration method | PN-EN 1911:2011 | |
| 51 | Automated Measuring Systems (AMS) | HCl concentration Range (0,5 – 500) mg/m3 |
Spectrophotometric method | PN-EN 1911:2011 | |
| 52 | Automated Measuring Systems (AMS) | Sampling for testing of hydrogen fluoride concentrations | Aspiration method | ISO 15713:2006 | |
| 53 | Automated Measuring Systems (AMS) | Gaseous fluoride concentration Range (0,1 – 200) mg/m3 |
Ion-selective electrode method | ISO 15713:2006 | |
| 54 | Waste gases | Sampling for determination of the concentrations of: sulfuric acid, hydrogen sulfide. | Aspiration method using absorbing solutions and membrane filters | Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r. | |
| 55 | Waste gases | Emission: sulphuric acid, hydrogen sulphide (calculated) | Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r. | ||
| 56 | Waste gases | Sampling for the determination of ammonia (NH3) concentration | PN-EN ISO 21877:2020-03 | ||
| 57 | Waste gases | Ammonia (NH3) concentration Range (1,0 – 100) mg/m3 |
Spectrophotometric method | PN-EN ISO 21877:2020-03 | |
| 58 | Waste gases | Ammonia (NH3) emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 59 | Waste gases | Nitrous oxide (N2O) concentration Range (1,4 – 400) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN ISO 21258:2010 | |
| 60 | Waste gases | Emission of nitrous oxide (N2O) (calculated) | PN-EN ISO 21258:2010 | ||
| 61 | Waste gases | Sampling for determination of metal concentrations in dust: zinc (Zn) | PN-Z-04030-7:1994 | ||
| 62 | Waste gases | Emission of metals in dust: Zn (calculated) | PN-Z-04030-7:1994 | ||
| 63 | Waste gases | Sampling for determination of metal concentrations in dust: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V | PN-EN 14385:2005 | ||
| 64 | Waste gases | Emission of metals in dust: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) | PN-EN 14385:2005 | ||
| 65 | Waste gases | Sampling for determination of the dust fraction | PN-Z-04030-7:1994 | Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r. | ||
| 66 | Waste gases | Emission of the dust fraction (calculated) | PN-Z-04030-7:1994 | Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r. | ||
| 67 | Waste gases | Sampling for determination of the concentration of dioxin-like PCB | PN-EN 1948-4+A1:2014-3 | ||
| 68 | Waste gases | PCB emission (calculated) | PN-EN 1948-4+A1:2014-3 | ||
| 69 | Waste gases | Sampling for determination of brominated flame retardants BFR | PN-EN 1948-1:2006 | Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r. | ||
| 70 | Waste gases | Emission of brominated flame retardants BFR (calculated) | PN-EN 1948-1:2006 | Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r. | ||
| 71 | Waste gases | Sampling for determination of polybrominated dibenzo-p-dioxins and furans PBDD/F | PN-EN 1948-1:2006 | Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r. | ||
| 72 | Waste gases | Emission of polybrominated dibenzo-p-dioxins and furans PBDD/F (calculated) | PN-EN 1948-1:2006 | Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r. | ||
| 73 | Automated Measuring Systems (AMS) | Calibration of AMS (QAL2) for: NH3, N2O | PN-EN 14181:2015-02 | ||
| 74 | Automated Measuring Systems (AMS) | Annual surveillance tests (AST) for: NH3, N2O | PN-EN 14181:2015-02 | ||
| 75 | Automated Measuring Systems (AMS) | Ammonia concentration Range (1,0 – 100) mg/m3 |
Spectrophotometric method | PN-EN ISO 21877:2020-03 | |
| 76 | Automated Measuring Systems (AMS) | Nitrous oxide (N2O) concentration Range (1,4 – 400) mg/m3 |
Non-dispersive infrared spectrometry (NDIR) | PN-EN ISO 21258:2010 | |
| 77 | Automated Measuring Systems (AMS) | Sampling for determination of total mercury concentration | Aspiration method | PN-EN 13211+AC:2006 | |
| 78 | Waste gas dedusting equipment | Dust concentration Range (0,001 - 100) g/m3 |
Gravimetric method | PN-87/M-34129 - metoda A | PN-Z-04030-7:1994 | |
| 79 | Waste gas dedusting equipment | Dust removal efficiency (calculated) | PN-87/M-34129 - metoda A | PN-Z-04030-7:1994 | ||
| 80 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound level LAeq Range (25 - 135) dB |
Direct measurement method | Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F | |
| 81 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound level for the reference time expressed by the indicators, LAeqD and LAeqN (calculated) | Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F | ||
Reference standards (28)
ISO 15713:2006
Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.
Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r.
Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r.
Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r.
Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r.
PN-87/M-34129 - metoda A
PN-EN 12619:2013-05
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 13649:2005
PN-EN 14181:2015-02
PN-EN 14385:2005
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 16911:2013-07
PN-EN 1911:2011
PN-EN 1948-1:2006
PN-EN 1948-4+A1:2014-3
PN-EN ISO 21258:2010
PN-EN ISO 21877:2020-03
PN-ISO 10396:2001
PN-Z-04008-4:1999
PN-Z-04030-7:1994
Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F