{"lab":{"_id":"69ad52a3de79e566650fb466","accr_number":"AB 872","country":"PL","accr_body":"PCA","address":"ul. Adama Mickiewicza 35A, 05-816 Michałowice, LABORATORIUM, ul. Rzeczna 10, 03-794 Warszawa","categories":["environment","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":81,"name":"TESMO Sp. z o. o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_872.pdf"],"scope_summary":"","search_text":"tesmo sp. z o. o. ul. adama mickiewicza 35a, 05-816 michałowice, laboratorium, ul. rzeczna 10, 03-794 warszawa other environment materials metrology","status":"active","updated_at":"2026-03-08T14:51:45.741Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:45.741Z","email_confidence":"high","email_mx":true,"email_source":"https://tesmo.pl/kontakt/","fields_of_testing":[{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise)."},{"codes":"M/39","pl":"Badania inne urządzeń ochrony powietrza","en":"Other tests of air protection equipment"},{"codes":"M/58","pl":"Badania inne automatycznych systemów monitoringu (AMS)","en":"Other tests of automatic monitoring systems (AMS)"},{"codes":"N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases"},{"codes":"P/36","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"}],"issue":{"no":"26","date":"07.07.2025"},"parse_date":"2026-07-20T07:09:53.018Z","parse_source":"script-pdfplumber","map_coord":[52.271611,20.983486],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":51,"environment":25,"materials":5,"metrology":2},"category_scores":{"other":31.34,"environment":7.53,"materials":0.3,"metrology":0.05},"has_zh":true},"methods":[{"_id":"6a5dc9c1f1c10c8ce825f3b1","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","parameters":[],"parameters_en":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"technique_en":"Stagnation pressure method","computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nMetoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method PN-Z-04030-7:1994","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 滞止压力法 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"滞止压力法"},{"_id":"6a5dc9c1f1c10c8ce825f3b2","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu. Prędkość.","methodology_en":"Gas volume flow rate. Velocity.","parameters":[{"name":"Zakres","range":"(1,0 – 30) m/s"}],"parameters_en":[{"name":"Range","range":"(1,0 – 30) m/s"}],"technique":"Metoda anemometryczna","techniques":["Metoda anemometryczna"],"technique_en":"Anemometric method","computed":[],"computed_en":[],"activity":"Strumień objętości gazu. Prędkość.\nZakres (1,0 – 30) m/s\nMetoda anemometryczna","reference":"PN-EN 16911:2013-07","norm_bases":["PN-EN 16911:2013-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu. Prędkość.\nZakres (1,0 – 30) m/s\nMetoda anemometryczna PN-EN 16911:2013-07 Gazy odlotowe Strumien objetosci gazu. Predkosc.\nZakres (1,0 – 30) m/s\nMetoda anemometryczna PN-EN 16911:2013-07","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gas volume flow rate. Velocity. Anemometric method Range PN-EN 16911:2013-07","parameters_zh":[{"name":"范围","range":"(1,0 – 30) m/s"}],"search_zh":"废气 风速仪法 范围 PN-EN 16911:2013-07","test_object_zh":"废气","technique_zh":"风速仪法"},{"_id":"6a5dc9c1f1c10c8ce825f3b3","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek pyłu do badań stężenia pyłu","methodology_en":"Dust sampling for testing of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek pyłu do badań stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do badań stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek pylu do badan stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust sampling for testing of dust concentration PN-Z-04030-7:1994","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3b4","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-Z-04030-7:1994","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3b5","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9c1f1c10c8ce825f3b6","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek pyłu do badań stężenia pyłu","methodology_en":"Dust sampling for testing of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek pyłu do badań stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do badań stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek pylu do badan stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust sampling for testing of dust concentration PN-EN 13284-1:2018-02","search_zh":"废气 PN-EN 13284-1:2018-02","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3b7","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(1,0 – 50) g/m3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 50) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (1,0 – 50) g/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (1,0 – 50) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (1,0 – 50) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 50) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3b8","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-EN 13284-1:2018-02","search_zh":"废气 粉尘排放量（计算值） PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9c1f1c10c8ce825f3b9","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie SO2","methodology_en":"SO2 concentration","parameters":[{"name":"Zakres","range":"(4,75 – 2500) mg/m3"}],"parameters_en":[{"name":"Range","range":"(4,75 – 2500) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie SO2\nZakres (4,75 – 2500) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie SO2\nZakres (4,75 – 2500) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie SO2\nZakres (4,75 – 2500) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO2 concentration Non-dispersive infrared spectrometry (NDIR) Range PN-ISO 10396:2001","parameters_zh":[{"name":"范围","range":"(4,75 – 2500) mg/m3"}],"search_zh":"废气 SO2 浓度 非分散红外光谱法（NDIR） 范围 PN-ISO 10396:2001","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"SO2 浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3ba","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO2 (z obliczeń)","methodology_en":"SO2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja SO2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO2 emission (calculated) PN-ISO 10396:2001","search_zh":"废气 SO2 排放量（计算值） PN-ISO 10396:2001","test_object_zh":"废气","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a5dc9c1f1c10c8ce825f3bb","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie NO, NOx","methodology_en":"NO, NOx concentration","parameters":[{"name":"NO","range":"(0,84 - 654) mg/m3"},{"name":"NOx","range":"(1,29 - 1000) mg/m3"}],"parameters_en":[{"name":"NO","range":"(0,84 - 654) mg/m3"},{"name":"NOx","range":"(1,29 - 1000) mg/m3"}],"technique":"Metoda chemiluminescencyjna (CLD)","techniques":["Metoda chemiluminescencyjna (CLD)"],"technique_en":"Chemiluminescence method (CLD)","computed":[],"computed_en":[],"activity":"Stężenie NO, NOx\nZakres:\nNO (0,84 - 654) mg/m3\nNOx (1,29 - 1000) mg/m3\nMetoda chemiluminescencyjna (CLD)","reference":"PN-ISO 10396:2001 | PN-EN 14792:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie NO, NOx\nZakres:\nNO (0,84 - 654) mg/m3\nNOx (1,29 - 1000) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-ISO 10396:2001 | PN-EN 14792:2017-04 Gazy odlotowe Stezenie NO, NOx\nZakres:\nNO (0,84 - 654) mg/m3\nNOx (1,29 - 1000) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-ISO 10396:2001 | PN-EN 14792:2017-04","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases NO, NOx concentration Chemiluminescence method (CLD) NO NOx PN-ISO 10396:2001 | PN-EN 14792:2017-04","search_zh":"废气 NO、NOx 浓度 化学发光法（CLD） NO NOx PN-ISO 10396:2001 | PN-EN 14792:2017-04","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(0,84 - 654) mg/m3"},{"name":"NOx","range":"(1,29 - 1000) mg/m3"}],"technique_zh":"化学发光法（CLD）","methodology_zh":"NO、NOx 浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3bc","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NO i NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","methodology_en":"Emission of NO and NOx (NO and NO2 calculated as NO2) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NO i NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PN-ISO 10396:2001 | PN-EN 14792:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NO i NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń) PN-ISO 10396:2001 | PN-EN 14792:2017-04 Gazy odlotowe Emisja NO i NOx (NO i NO2 w przeliczeniu na NO2) (z obliczen) PN-ISO 10396:2001 | PN-EN 14792:2017-04","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of NO and NOx (NO and NO2 calculated as NO2) (calculated) PN-ISO 10396:2001 | PN-EN 14792:2017-04","search_zh":"废气 PN-ISO 10396:2001 | PN-EN 14792:2017-04","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3bd","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia SO2","methodology_en":"Sampling for determination of SO2 concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia SO2","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia SO2 PN-EN 14791:2017-04 Gazy odlotowe Pobieranie probek do oznaczania stezenia SO2 PN-EN 14791:2017-04","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of SO2 concentration PN-EN 14791:2017-04","search_zh":"废气 用于测定 SO2 浓度的采样 PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"用于测定 SO2 浓度的采样"},{"_id":"6a5dc9c1f1c10c8ce825f3be","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie SO2","methodology_en":"SO2 concentration","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Stężenie SO2\nZakres (5,0 – 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie SO2\nZakres (5,0 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Gazy odlotowe Stezenie SO2\nZakres (5,0 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO2 concentration Thoron method Range PN-EN 14791:2017-04","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/m3"}],"search_zh":"废气 SO2 浓度 钍射气法 范围 PN-EN 14791:2017-04","test_object_zh":"废气","technique_zh":"钍射气法","methodology_zh":"SO2 浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3bf","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO2 (z obliczeń)","methodology_en":"SO2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-EN 14791:2017-04 Gazy odlotowe Emisja SO2 (z obliczen) PN-EN 14791:2017-04","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO2 emission (calculated) PN-EN 14791:2017-04","search_zh":"废气 SO2 排放量（计算值） PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a5dc9c1f1c10c8ce825f3c0","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu","methodology_en":"Oxygen concentration","parameters":[{"name":"Zakres","range":"(0,2 – 21) %"}],"parameters_en":[{"name":"Range","range":"(0,2 – 21) %"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu\nZakres (0,2 – 21) %\nMetoda elektrochemiczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (0,2 – 21) %\nMetoda elektrochemiczna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu\nZakres (0,2 – 21) %\nMetoda elektrochemiczna PN-ISO 10396:2001","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Oxygen concentration Electrochemical method Range PN-ISO 10396:2001","parameters_zh":[{"name":"范围","range":"(0,2 – 21) %"}],"search_zh":"废气 氧浓度 电化学法 范围 PN-ISO 10396:2001","technique_zh":"电化学法","test_object_zh":"废气","methodology_zh":"氧浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3c1","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu","methodology_en":"Oxygen concentration","parameters":[{"name":"Zakres","range":"(1 – 21) %"}],"parameters_en":[{"name":"Range","range":"(1 – 21) %"}],"technique":"Metoda paramagnetyczna (PMD)","techniques":["Metoda paramagnetyczna (PMD)"],"technique_en":"Paramagnetic method (PMD)","computed":[],"computed_en":[],"activity":"Stężenie tlenu\nZakres (1 – 21) %\nMetoda paramagnetyczna (PMD)","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (1 – 21) %\nMetoda paramagnetyczna (PMD) PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu\nZakres (1 – 21) %\nMetoda paramagnetyczna (PMD) PN-EN 14789:2017-04","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Oxygen concentration Paramagnetic method (PMD) Range PN-EN 14789:2017-04","parameters_zh":[{"name":"范围","range":"(1 – 21) %"}],"search_zh":"废气 氧浓度 顺磁法（PMD） 范围 PN-EN 14789:2017-04","test_object_zh":"废气","methodology_zh":"氧浓度","technique_zh":"顺磁法（PMD）"},{"_id":"6a5dc9c1f1c10c8ce825f3c2","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie CO","methodology_en":"CO concentration","parameters":[{"name":"Zakres","range":"(2,40 – 740) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,40 – 740) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie CO\nZakres (2,40 – 740) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04 | PN-ISO 10396:2001","norm_bases":["PN-EN 15058:2017-04","PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie CO\nZakres (2,40 – 740) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 | PN-ISO 10396:2001 Gazy odlotowe Stezenie CO\nZakres (2,40 – 740) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 | PN-ISO 10396:2001","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases CO concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN 15058:2017-04 | PN-ISO 10396:2001","parameters_zh":[{"name":"范围","range":"(2,40 – 740) mg/m3"}],"search_zh":"废气 CO 浓度 非分散红外光谱法（NDIR） 范围 PN-EN 15058:2017-04 | PN-ISO 10396:2001","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"CO 浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3c3","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO (z obliczeń)","methodology_en":"CO emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO (z obliczeń)","reference":"PN-EN 15058:2017-04 | PN-ISO 10396:2001","norm_bases":["PN-EN 15058:2017-04","PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO (z obliczeń) PN-EN 15058:2017-04 | PN-ISO 10396:2001 Gazy odlotowe Emisja CO (z obliczen) PN-EN 15058:2017-04 | PN-ISO 10396:2001","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases CO emission (calculated) PN-EN 15058:2017-04 | PN-ISO 10396:2001","search_zh":"废气 CO 排放量（计算值） PN-EN 15058:2017-04 | PN-ISO 10396:2001","test_object_zh":"废气","methodology_zh":"CO 排放量（计算值）"},{"_id":"6a5dc9c1f1c10c8ce825f3c4","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku węgla","methodology_en":"Carbon dioxide concentration","parameters":[{"name":"Zakres","range":"(0,2 – 25) %"}],"parameters_en":[{"name":"Range","range":"(0,2 – 25) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie dwutlenku węgla\nZakres (0,2 – 25) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku węgla\nZakres (0,2 – 25) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku wegla\nZakres (0,2 – 25) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Carbon dioxide concentration Non-dispersive infrared spectrometry (NDIR) Range PN-ISO 10396:2001","parameters_zh":[{"name":"范围","range":"(0,2 – 25) %"}],"search_zh":"废气 二氧化碳浓度 非分散红外光谱法（NDIR） 范围 PN-ISO 10396:2001","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"二氧化碳浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3c5","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/m3"}],"technique":"Metoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną (FID)","techniques":["Metoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną (FID)"],"technique_en":"Continuous measurement with flame ionization detection (FID)","computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,0 – 1000) mg/m3\nMetoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,0 – 1000) mg/m3\nMetoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (1,0 – 1000) mg/m3\nMetoda ciaglego pomiaru z detekcja plomieniowo-jonizacyjna (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous measurement with flame ionization detection (FID) Range PN-EN 12619:2013-05","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/m3"}],"search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物浓度 范围 PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3c6","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN-EN 12619:2013-05 Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN-EN 12619:2013-05","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) PN-EN 12619:2013-05","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值） PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）"},{"_id":"6a5dc9c1f1c10c8ce825f3c7","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pary wodnej (H2O)","methodology_en":"Water vapour concentration (H2O)","parameters":[{"name":"Zakres","range":"(4,0 – 26) % obj."}],"parameters_en":[{"name":"Range","range":"(4,0 – 26) % obj."}],"technique":"Metoda adsorpcyjna","techniques":["Metoda adsorpcyjna"],"technique_en":"Adsorption method","computed":[],"computed_en":[],"activity":"Stężenie pary wodnej (H2O)\nZakres (4,0 – 26) % obj.\nMetoda adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O)\nZakres (4,0 – 26) % obj.\nMetoda adsorpcyjna PN-EN 14790:2017-04 Gazy odlotowe Stezenie pary wodnej (H2O)\nZakres (4,0 – 26) % obj.\nMetoda adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Water vapour concentration (H2O) Adsorption method Range PN-EN 14790:2017-04","parameters_zh":[{"name":"范围","range":"(4,0 – 26) % obj."}],"search_zh":"废气 水蒸气浓度（H2O） 范围 PN-EN 14790:2017-04","test_object_zh":"废气","methodology_zh":"水蒸气浓度（H2O）"},{"_id":"6a5dc9c1f1c10c8ce825f3c8","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia PCDD/PCDFs","methodology_en":"Sampling for determination of the concentration of PCDD/PCDFs","parameters":[],"parameters_en":[],"technique":"Metoda filtracji i kondensacji","techniques":["Metoda filtracji i kondensacji"],"technique_en":"Filtration and condensation method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia PCDD/PCDFs\nMetoda filtracji i kondensacji","reference":"PN-EN 1948-1:2006","norm_bases":["PN-EN 1948-1:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia PCDD/PCDFs\nMetoda filtracji i kondensacji PN-EN 1948-1:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia PCDD/PCDFs\nMetoda filtracji i kondensacji PN-EN 1948-1:2006","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentration of PCDD/PCDFs Filtration and condensation method PN-EN 1948-1:2006","search_zh":"废气 过滤与冷凝法 PN-EN 1948-1:2006","test_object_zh":"废气","technique_zh":"过滤与冷凝法"},{"_id":"6a5dc9c1f1c10c8ce825f3c9","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków PCDD/PCDFs (z obliczeń)","methodology_en":"Emission of PCDD/PCDFs compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków PCDD/PCDFs (z obliczeń)","reference":"PN-EN 1948-1:2006","norm_bases":["PN-EN 1948-1:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków PCDD/PCDFs (z obliczeń) PN-EN 1948-1:2006 Gazy odlotowe Emisja zwiazkow PCDD/PCDFs (z obliczen) PN-EN 1948-1:2006","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of PCDD/PCDFs compounds (calculated) PN-EN 1948-1:2006","search_zh":"废气 PN-EN 1948-1:2006","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3ca","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","norm_bases":["PN-EN 13649:2005","Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","search_zh":"废气 单项气态有机化合物浓度测定采样 PN-EN 13649:2005 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","test_object_zh":"废气","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a5dc9c1f1c10c8ce825f3cb","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","methodology_en":"Emission of individual gaseous organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","norm_bases":["PN-EN 13649:2005","Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r. Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) PN-EN 13649:2005 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","search_zh":"废气 单项气态有机化合物排放量（计算值） PN-EN 13649:2005 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a5dc9c1f1c10c8ce825f3cc","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń chlorowodoru","methodology_en":"Sampling for determination of hydrogen chloride concentrations","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"technique_en":"Aspiration method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń chlorowodoru\nMetoda aspiracyjna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń chlorowodoru\nMetoda aspiracyjna PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczania stezen chlorowodoru\nMetoda aspiracyjna PN-EN 1911:2011","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of hydrogen chloride concentrations Aspiration method PN-EN 1911:2011","search_zh":"废气 抽气法 PN-EN 1911:2011","test_object_zh":"废气","technique_zh":"抽气法"},{"_id":"6a5dc9c1f1c10c8ce825f3cd","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie HCl","methodology_en":"HCl concentration","parameters":[{"name":"Zakres","range":"(0,5 – 500) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,5 – 500) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie HCl\nZakres (0,5 – 500) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie HCl\nZakres (0,5 – 500) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 Gazy odlotowe Stezenie HCl\nZakres (0,5 – 500) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases HCl concentration Spectrophotometric method Range PN-EN 1911:2011","parameters_zh":[{"name":"范围","range":"(0,5 – 500) mg/m3"}],"search_zh":"废气 HCl 浓度 分光光度法 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"HCl 浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3ce","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja HCl (z obliczeń)","methodology_en":"HCl emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja HCl (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja HCl (z obliczeń) PN-EN 1911:2011 Gazy odlotowe Emisja HCl (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases HCl emission (calculated) PN-EN 1911:2011","search_zh":"废气 HCl 排放（由计算得出） PN-EN 1911:2011","test_object_zh":"废气","methodology_zh":"HCl 排放（由计算得出）"},{"_id":"6a5dc9c1f1c10c8ce825f3cf","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","methodology_en":"Sampling for determination of total mercury concentration","parameters":[],"parameters_en":[],"technique":"Metoda filtracyjno-aspiracyjna","techniques":["Metoda filtracyjno-aspiracyjna"],"technique_en":"Filtration-aspiration method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej\nMetoda filtracyjno-aspiracyjna","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej\nMetoda filtracyjno-aspiracyjna PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej\nMetoda filtracyjno-aspiracyjna PN-EN 13211+AC:2006","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of total mercury concentration Filtration-aspiration method PN-EN 13211+AC:2006","search_zh":"废气 总汞浓度测定采样 PN-EN 13211+AC:2006","test_object_zh":"废气","methodology_zh":"总汞浓度测定采样"},{"_id":"6a5dc9c1f1c10c8ce825f3d0","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja rtęci ogólnej (z obliczeń)","methodology_en":"Total mercury emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja rtęci ogólnej (z obliczeń) PN-EN 13211+AC:2006 Gazy odlotowe Emisja rteci ogolnej (z obliczen) PN-EN 13211+AC:2006","categories":["environment"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Total mercury emission (calculated) PN-EN 13211+AC:2006","search_zh":"废气 总汞排放量（计算值） PN-EN 13211+AC:2006","test_object_zh":"废气","methodology_zh":"总汞排放量（计算值）"},{"_id":"6a5dc9c1f1c10c8ce825f3d1","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych","methodology_en":"Sampling for determination of concentrations of organic compounds","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych","reference":"PN-Z-04008-4:1999 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","norm_bases":["PN-Z-04008-4:1999","Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych PN-Z-04008-4:1999 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r. Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych PN-Z-04008-4:1999 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of concentrations of organic compounds PN-Z-04008-4:1999 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","search_zh":"废气 有机化合物浓度测定采样 PN-Z-04008-4:1999 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","test_object_zh":"废气","methodology_zh":"有机化合物浓度测定采样"},{"_id":"6a5dc9c1f1c10c8ce825f3d2","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków organicznych (z obliczeń)","methodology_en":"Emission of organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"PN-Z-04008-4:1999 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","norm_bases":["PN-Z-04008-4:1999","Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) PN-Z-04008-4:1999 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r. Gazy odlotowe Emisja zwiazkow organicznych (z obliczen) PN-Z-04008-4:1999 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","categories":["environment"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of organic compounds (calculated) PN-Z-04008-4:1999 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","search_zh":"废气 有机化合物排放量（计算值） PN-Z-04008-4:1999 | Instrukcja robocza IR-17 wydanie 5 z dnia 06.06.2024 r.","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"},{"_id":"6a5dc9c1f1c10c8ce825f3d3","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do badań stężeń fluorowodoru","methodology_en":"Sampling for testing of hydrogen fluoride concentrations","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"technique_en":"Aspiration method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań stężeń fluorowodoru\nMetoda aspiracyjna","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do badań stężeń fluorowodoru\nMetoda aspiracyjna ISO 15713:2006 Gazy odlotowe Pobieranie probek do badan stezen fluorowodoru\nMetoda aspiracyjna ISO 15713:2006","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for testing of hydrogen fluoride concentrations Aspiration method ISO 15713:2006","search_zh":"废气 抽气法 ISO 15713:2006","test_object_zh":"废气","technique_zh":"抽气法"},{"_id":"6a5dc9c1f1c10c8ce825f3d4","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie fluorków gazowych","methodology_en":"Gaseous fluoride concentration","parameters":[{"name":"Zakres","range":"(0,1 – 200) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,1 – 200) mg/m3"}],"technique":"Metoda elektrody jonoselektywnej","techniques":["Metoda elektrody jonoselektywnej"],"technique_en":"Ion-selective electrode method","computed":[],"computed_en":[],"activity":"Stężenie fluorków gazowych\nZakres (0,1 – 200) mg/m3\nMetoda elektrody jonoselektywnej","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie fluorków gazowych\nZakres (0,1 – 200) mg/m3\nMetoda elektrody jonoselektywnej ISO 15713:2006 Gazy odlotowe Stezenie fluorkow gazowych\nZakres (0,1 – 200) mg/m3\nMetoda elektrody jonoselektywnej ISO 15713:2006","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gaseous fluoride concentration Ion-selective electrode method Range ISO 15713:2006","parameters_zh":[{"name":"范围","range":"(0,1 – 200) mg/m3"}],"search_zh":"废气 范围 ISO 15713:2006","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3d5","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja HF (z obliczeń)","methodology_en":"HF emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja HF (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) ISO 15713:2006 Gazy odlotowe Emisja HF (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases HF emission (calculated) ISO 15713:2006","search_zh":"废气 HF 排放量（计算值） ISO 15713:2006","test_object_zh":"废气","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a5dc9c1f1c10c8ce825f3d6","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczenia stężenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)","methodology_en":"Sampling for determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczenia stężenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) PN-EN 14385:2005 Gazy odlotowe Pobieranie probek do oznaczenia stezenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) PN-EN 14385:2005","categories":["materials"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) PN-EN 14385:2005","search_zh":"废气 PN-EN 14385:2005","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3d7","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","methodology_en":"Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń) PN-EN 14385:2005 Gazy odlotowe Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczen) PN-EN 14385:2005","categories":["environment"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) PN-EN 14385:2005","search_zh":"废气 As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V 排放（由计算得出） PN-EN 14385:2005","test_object_zh":"废气","methodology_zh":"As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V 排放（由计算得出）"},{"_id":"6a5dc9c1f1c10c8ce825f3d8","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie: pyłu, CO2 , substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg","methodology_en":"AMS calibration (QAL2) for: dust, CO2 , organic substances in the form of gases and vapours expressed as total gaseous organic carbon, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kalibracja AMS (QAL2) w zakresie: pyłu, CO2 , substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: pyłu, CO2 , substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: pylu, CO2 , substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg PN-EN 14181:2015-02","categories":["metrology"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) AMS calibration (QAL2) for: dust, CO2 , organic substances in the form of gases and vapours expressed as total gaseous organic carbon, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg PN-EN 14181:2015-02","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c1f1c10c8ce825f3d9","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Roczne badania kontrolne (AST) w zakresie: pyłu, CO2 , substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg","methodology_en":"Annual surveillance tests (AST) for: dust, CO2 , organic substances in the form of gases and vapours expressed as total gaseous organic carbon, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Roczne badania kontrolne (AST) w zakresie: pyłu, CO2 , substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Roczne badania kontrolne (AST) w zakresie: pyłu, CO2 , substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Roczne badania kontrolne (AST) w zakresie: pylu, CO2 , substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg PN-EN 14181:2015-02","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Annual surveillance tests (AST) for: dust, CO2 , organic substances in the form of gases and vapours expressed as total gaseous organic carbon, NO, NOx, SO2, CO, O2, H2O, HF, HCl, Hg PN-EN 14181:2015-02","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c1f1c10c8ce825f3da","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Automatyczne Systemy, Monitoringu (AMS) Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Range PN-Z-04030-7:1994","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c1f1c10c8ce825f3db","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie CO2","methodology_en":"CO2 concentration","parameters":[{"name":"Zakres","range":"(0,2 – 25) %"}],"parameters_en":[{"name":"Range","range":"(0,2 – 25) %"}],"technique":"Metoda NDIR","techniques":["Metoda NDIR"],"technique_en":"NDIR method","computed":[],"computed_en":[],"activity":"Stężenie CO2\nZakres (0,2 – 25) %\nMetoda NDIR","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie CO2\nZakres (0,2 – 25) %\nMetoda NDIR PN-ISO 10396:2001 Automatyczne Systemy, Monitoringu (AMS) Stezenie CO2\nZakres (0,2 – 25) %\nMetoda NDIR PN-ISO 10396:2001","categories":["other"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) CO2 concentration NDIR method Range PN-ISO 10396:2001","parameters_zh":[{"name":"范围","range":"(0,2 – 25) %"}],"search_zh":"自动测量系统（AMS） CO2 浓度 非分散红外法（NDIR） 范围 PN-ISO 10396:2001","test_object_zh":"自动测量系统（AMS）","methodology_zh":"CO2 浓度","technique_zh":"非分散红外法（NDIR）"},{"_id":"6a5dc9c1f1c10c8ce825f3dc","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/m3"}],"technique":"Metoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną (FID)","techniques":["Metoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną (FID)"],"technique_en":"Continuous measurement with flame ionization detection (FID)","computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,0 – 1000) mg/m3\nMetoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,0 – 1000) mg/m3\nMetoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną (FID) PN-EN 12619:2013-05 Automatyczne Systemy, Monitoringu (AMS) Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (1,0 – 1000) mg/m3\nMetoda ciaglego pomiaru z detekcja plomieniowo-jonizacyjna (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous measurement with flame ionization detection (FID) Range PN-EN 12619:2013-05","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/m3"}],"search_zh":"自动测量系统（AMS） 以总气态有机碳表示的气态与蒸气态有机物浓度 范围 PN-EN 12619:2013-05","test_object_zh":"自动测量系统（AMS）","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3dd","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie NO, NOx","methodology_en":"NO, NOx concentration","parameters":[{"name":"NO","range":"(0,84 – 654) mg/m3"},{"name":"NOX","range":"(1,29 – 1000) mg/m3"}],"parameters_en":[{"name":"NO","range":"(0,84 – 654) mg/m3"},{"name":"NOX","range":"(1,29 – 1000) mg/m3"}],"technique":"Metoda chemiluminescencyjna (CLD)","techniques":["Metoda chemiluminescencyjna (CLD)"],"technique_en":"Chemiluminescence method (CLD)","computed":[],"computed_en":[],"activity":"Stężenie NO, NOx\nZakres:\nNO (0,84 – 654) mg/m3\nNOX (1,29 – 1000) mg/m3\nMetoda chemiluminescencyjna (CLD)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie NO, NOx\nZakres:\nNO (0,84 – 654) mg/m3\nNOX (1,29 – 1000) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie NO, NOx\nZakres:\nNO (0,84 – 654) mg/m3\nNOX (1,29 – 1000) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04","categories":["other"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) NO, NOx concentration Chemiluminescence method (CLD) NO NOX PN-EN 14792:2017-04","search_zh":"自动测量系统（AMS） NO、NOx 浓度 化学发光法（CLD） NO PN-EN 14792:2017-04","test_object_zh":"自动测量系统（AMS）","parameters_zh":[{"name":"NO","range":"(0,84 – 654) mg/m3"},{"name":"NOX","range":"(1,29 – 1000) mg/m3"}],"technique_zh":"化学发光法（CLD）","methodology_zh":"NO、NOx 浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3de","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie SO2","methodology_en":"SO2 concentration","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Stężenie SO2\nZakres (5,0 – 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie SO2\nZakres (5,0 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie SO2\nZakres (5,0 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) SO2 concentration Thoron method Range PN-EN 14791:2017-04","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/m3"}],"search_zh":"自动测量系统（AMS） SO2 浓度 钍射气法 范围 PN-EN 14791:2017-04","test_object_zh":"自动测量系统（AMS）","technique_zh":"钍射气法","methodology_zh":"SO2 浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3df","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie CO","methodology_en":"CO concentration","parameters":[{"name":"Zakres","range":"(2,4 – 740) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,4 – 740) mg/m3"}],"technique":"Metoda spektrometrii niedyspersyjnej w podczerwieni (NDIR)","techniques":["Metoda spektrometrii niedyspersyjnej w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie CO\nZakres (2,4 – 740) mg/m3\nMetoda spektrometrii niedyspersyjnej w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie CO\nZakres (2,4 – 740) mg/m3\nMetoda spektrometrii niedyspersyjnej w podczerwieni (NDIR) PN-EN 15058:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie CO\nZakres (2,4 – 740) mg/m3\nMetoda spektrometrii niedyspersyjnej w podczerwieni (NDIR) PN-EN 15058:2017-04","categories":["other"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) CO concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN 15058:2017-04","parameters_zh":[{"name":"范围","range":"(2,4 – 740) mg/m3"}],"search_zh":"自动测量系统（AMS） CO 浓度 范围 PN-EN 15058:2017-04","test_object_zh":"自动测量系统（AMS）","methodology_zh":"CO 浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3e0","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie O2","methodology_en":"O2 concentration","parameters":[{"name":"Zakres","range":"(1,0 – 21) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 21) %"}],"technique":"Metoda paramagnetyczna (PMD)","techniques":["Metoda paramagnetyczna (PMD)"],"technique_en":"Paramagnetic method (PMD)","computed":[],"computed_en":[],"activity":"Stężenie O2\nZakres (1,0 – 21) %\nMetoda paramagnetyczna (PMD)","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie O2\nZakres (1,0 – 21) %\nMetoda paramagnetyczna (PMD) PN-EN 14789:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie O2\nZakres (1,0 – 21) %\nMetoda paramagnetyczna (PMD) PN-EN 14789:2017-04","categories":["other"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) O2 concentration Paramagnetic method (PMD) Range PN-EN 14789:2017-04","parameters_zh":[{"name":"范围","range":"(1,0 – 21) %"}],"search_zh":"自动测量系统（AMS） O2 浓度 顺磁法（PMD） 范围 PN-EN 14789:2017-04","test_object_zh":"自动测量系统（AMS）","methodology_zh":"O2 浓度","technique_zh":"顺磁法（PMD）"},{"_id":"6a5dc9c1f1c10c8ce825f3e1","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pary wodnej (H2O)","methodology_en":"Water vapour concentration (H2O)","parameters":[{"name":"Zakres","range":"(4,0 – 26) % obj."}],"parameters_en":[{"name":"Range","range":"(4,0 – 26) % obj."}],"technique":"Metoda adsorpcyjna","techniques":["Metoda adsorpcyjna"],"technique_en":"Adsorption method","computed":[],"computed_en":[],"activity":"Stężenie pary wodnej (H2O)\nZakres (4,0 – 26) % obj.\nMetoda adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pary wodnej (H2O)\nZakres (4,0 – 26) % obj.\nMetoda adsorpcyjna PN-EN 14790:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie pary wodnej (H2O)\nZakres (4,0 – 26) % obj.\nMetoda adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Water vapour concentration (H2O) Adsorption method Range PN-EN 14790:2017-04","parameters_zh":[{"name":"范围","range":"(4,0 – 26) % obj."}],"search_zh":"自动测量系统（AMS） 水蒸气浓度（H2O） 范围 PN-EN 14790:2017-04","test_object_zh":"自动测量系统（AMS）","methodology_zh":"水蒸气浓度（H2O）"},{"_id":"6a5dc9c1f1c10c8ce825f3e2","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Pobieranie próbek do badań stężeń chlorowodoru","methodology_en":"Sampling for testing of hydrogen chloride concentrations","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"technique_en":"Aspiration method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań stężeń chlorowodoru\nMetoda aspiracyjna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Pobieranie próbek do badań stężeń chlorowodoru\nMetoda aspiracyjna PN-EN 1911:2011 Automatyczne Systemy, Monitoringu (AMS) Pobieranie probek do badan stezen chlorowodoru\nMetoda aspiracyjna PN-EN 1911:2011","categories":["other"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Sampling for testing of hydrogen chloride concentrations Aspiration method PN-EN 1911:2011","search_zh":"自动测量系统（AMS） 抽气法 PN-EN 1911:2011","test_object_zh":"自动测量系统（AMS）","technique_zh":"抽气法"},{"_id":"6a5dc9c1f1c10c8ce825f3e3","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie HCl","methodology_en":"HCl concentration","parameters":[{"name":"Zakres","range":"(0,5 – 500) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,5 – 500) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie HCl\nZakres (0,5 – 500) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie HCl\nZakres (0,5 – 500) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 Automatyczne Systemy, Monitoringu (AMS) Stezenie HCl\nZakres (0,5 – 500) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) HCl concentration Spectrophotometric method Range PN-EN 1911:2011","parameters_zh":[{"name":"范围","range":"(0,5 – 500) mg/m3"}],"search_zh":"自动测量系统（AMS） HCl 浓度 分光光度法 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"HCl 浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3e4","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Pobieranie próbek do badań stężeń fluorowodoru","methodology_en":"Sampling for testing of hydrogen fluoride concentrations","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"technique_en":"Aspiration method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań stężeń fluorowodoru\nMetoda aspiracyjna","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Pobieranie próbek do badań stężeń fluorowodoru\nMetoda aspiracyjna ISO 15713:2006 Automatyczne Systemy, Monitoringu (AMS) Pobieranie probek do badan stezen fluorowodoru\nMetoda aspiracyjna ISO 15713:2006","categories":["other"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Sampling for testing of hydrogen fluoride concentrations Aspiration method ISO 15713:2006","search_zh":"自动测量系统（AMS） 抽气法 ISO 15713:2006","test_object_zh":"自动测量系统（AMS）","technique_zh":"抽气法"},{"_id":"6a5dc9c1f1c10c8ce825f3e5","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie fluorków gazowych","methodology_en":"Gaseous fluoride concentration","parameters":[{"name":"Zakres","range":"(0,1 – 200) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,1 – 200) mg/m3"}],"technique":"Metoda elektrody jonoselektywnej","techniques":["Metoda elektrody jonoselektywnej"],"technique_en":"Ion-selective electrode method","computed":[],"computed_en":[],"activity":"Stężenie fluorków gazowych\nZakres (0,1 – 200) mg/m3\nMetoda elektrody jonoselektywnej","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie fluorków gazowych\nZakres (0,1 – 200) mg/m3\nMetoda elektrody jonoselektywnej ISO 15713:2006 Automatyczne Systemy, Monitoringu (AMS) Stezenie fluorkow gazowych\nZakres (0,1 – 200) mg/m3\nMetoda elektrody jonoselektywnej ISO 15713:2006","categories":["other"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Gaseous fluoride concentration Ion-selective electrode method Range ISO 15713:2006","parameters_zh":[{"name":"范围","range":"(0,1 – 200) mg/m3"}],"search_zh":"自动测量系统（AMS） 范围 ISO 15713:2006","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c1f1c10c8ce825f3e6","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń: kwasu siarkowego, siarkowodoru.","methodology_en":"Sampling for determination of the concentrations of: sulfuric acid, hydrogen sulfide.","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających i filtrów membranowych","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających i filtrów membranowych"],"technique_en":"Aspiration method using absorbing solutions and membrane filters","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń: kwasu siarkowego, siarkowodoru.\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających i filtrów membranowych","reference":"Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r.","norm_bases":["Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń: kwasu siarkowego, siarkowodoru.\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających i filtrów membranowych Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r. Gazy odlotowe Pobieranie probek do oznaczania stezen: kwasu siarkowego, siarkowodoru.\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych i filtrow membranowych Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r.","categories":["other"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentrations of: sulfuric acid, hydrogen sulfide. Aspiration method using absorbing solutions and membrane filters Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r.","search_zh":"废气 Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r.","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3e7","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja: kwasu siarkowego, siarkowodoru (z obliczeń)","methodology_en":"Emission: sulphuric acid, hydrogen sulphide (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja: kwasu siarkowego, siarkowodoru (z obliczeń)","reference":"Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r.","norm_bases":["Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja: kwasu siarkowego, siarkowodoru (z obliczeń) Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r. Gazy odlotowe Emisja: kwasu siarkowego, siarkowodoru (z obliczen) Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r.","categories":["environment"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission: sulphuric acid, hydrogen sulphide (calculated) Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r.","search_zh":"废气 Instrukcja robocza IR-43 wydanie 7 z dnia 06.06.2024 r.","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3e8","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku (NH3)","methodology_en":"Sampling for the determination of ammonia (NH3) concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku (NH3)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia amoniaku (NH3) PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia amoniaku (NH3) PN-EN ISO 21877:2020-03","categories":["other"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for the determination of ammonia (NH3) concentration PN-EN ISO 21877:2020-03","search_zh":"废气 PN-EN ISO 21877:2020-03","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3e9","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie amoniaku (NH3)","methodology_en":"Ammonia (NH3) concentration","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 100) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie amoniaku (NH3)\nZakres (1,0 – 100) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie amoniaku (NH3)\nZakres (1,0 – 100) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Gazy odlotowe Stezenie amoniaku (NH3)\nZakres (1,0 – 100) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Ammonia (NH3) concentration Spectrophotometric method Range PN-EN ISO 21877:2020-03","parameters_zh":[{"name":"范围","range":"(1,0 – 100) mg/m3"}],"search_zh":"废气 分光光度法 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3ea","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja amoniaku (NH3) (z obliczeń)","methodology_en":"Ammonia (NH3) emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja amoniaku (NH3) (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja amoniaku (NH3) (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe Emisja amoniaku (NH3) (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Ammonia (NH3) emission (calculated) PN-EN ISO 21877:2020-03","search_zh":"废气 氨（NH3）排放（由计算得出） PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"氨（NH3）排放（由计算得出）"},{"_id":"6a5dc9c1f1c10c8ce825f3eb","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie podtlenku azotu (N2O)","methodology_en":"Nitrous oxide (N2O) concentration","parameters":[{"name":"Zakres","range":"(1,4 – 400) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,4 – 400) mg/m3"}],"technique":"Metoda spektrometrii niedyspersyjnej w podczerwieni (NDIR)","techniques":["Metoda spektrometrii niedyspersyjnej w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie podtlenku azotu (N2O)\nZakres (1,4 – 400) mg/m3\nMetoda spektrometrii niedyspersyjnej w podczerwieni (NDIR)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie podtlenku azotu (N2O)\nZakres (1,4 – 400) mg/m3\nMetoda spektrometrii niedyspersyjnej w podczerwieni (NDIR) PN-EN ISO 21258:2010 Gazy odlotowe Stezenie podtlenku azotu (N2O)\nZakres (1,4 – 400) mg/m3\nMetoda spektrometrii niedyspersyjnej w podczerwieni (NDIR) PN-EN ISO 21258:2010","categories":["other"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Nitrous oxide (N2O) concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN ISO 21258:2010","parameters_zh":[{"name":"范围","range":"(1,4 – 400) mg/m3"}],"search_zh":"废气 范围 PN-EN ISO 21258:2010","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3ec","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja podtlenku azotu (N2O) (z obliczeń)","methodology_en":"Emission of nitrous oxide (N2O) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja podtlenku azotu (N2O) (z obliczeń)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja podtlenku azotu (N2O) (z obliczeń) PN-EN ISO 21258:2010 Gazy odlotowe Emisja podtlenku azotu (N2O) (z obliczen) PN-EN ISO 21258:2010","categories":["environment"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of nitrous oxide (N2O) (calculated) PN-EN ISO 21258:2010","search_zh":"废气 PN-EN ISO 21258:2010","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3ed","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia metali w pyle: cynk (Zn)","methodology_en":"Sampling for determination of metal concentrations in dust: zinc (Zn)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia metali w pyle: cynk (Zn)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali w pyle: cynk (Zn) PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia metali w pyle: cynk (Zn) PN-Z-04030-7:1994","categories":["materials"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of metal concentrations in dust: zinc (Zn) PN-Z-04030-7:1994","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3ee","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metali w pyle: Zn (z obliczeń)","methodology_en":"Emission of metals in dust: Zn (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metali w pyle: Zn (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metali w pyle: Zn (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja metali w pyle: Zn (z obliczen) PN-Z-04030-7:1994","categories":["materials","environment"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of metals in dust: Zn (calculated) PN-Z-04030-7:1994","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3ef","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia metali w pyle: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","methodology_en":"Sampling for determination of metal concentrations in dust: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia metali w pyle: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali w pyle: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia metali w pyle: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2005","categories":["materials"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of metal concentrations in dust: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2005","search_zh":"废气 PN-EN 14385:2005","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3f0","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metali w pyle: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","methodology_en":"Emission of metals in dust: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metali w pyle: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metali w pyle: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń) PN-EN 14385:2005 Gazy odlotowe Emisja metali w pyle: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczen) PN-EN 14385:2005","categories":["materials","environment"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of metals in dust: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) PN-EN 14385:2005","search_zh":"废气 PN-EN 14385:2005","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3f1","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania frakcji pyłu","methodology_en":"Sampling for determination of the dust fraction","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania frakcji pyłu","reference":"PN-Z-04030-7:1994 | Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r.","norm_bases":["PN-Z-04030-7:1994","Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania frakcji pyłu PN-Z-04030-7:1994 | Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r. Gazy odlotowe Pobieranie probek do oznaczania frakcji pylu PN-Z-04030-7:1994 | Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r.","categories":["other"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the dust fraction PN-Z-04030-7:1994 | Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r.","search_zh":"废气 用于测定粉尘分级的采样 PN-Z-04030-7:1994 | Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r.","test_object_zh":"废气","methodology_zh":"用于测定粉尘分级的采样"},{"_id":"6a5dc9c1f1c10c8ce825f3f2","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja frakcji pyłu (z obliczeń)","methodology_en":"Emission of the dust fraction (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja frakcji pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994 | Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r.","norm_bases":["PN-Z-04030-7:1994","Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja frakcji pyłu (z obliczeń) PN-Z-04030-7:1994 | Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r. Gazy odlotowe Emisja frakcji pylu (z obliczen) PN-Z-04030-7:1994 | Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r.","categories":["environment"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of the dust fraction (calculated) PN-Z-04030-7:1994 | Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r.","search_zh":"废气 粉尘分级排放（由计算得出） PN-Z-04030-7:1994 | Instrukcja robocza IR-48 wydanie 1 z dnia 19.07.2018 r.","test_object_zh":"废气","methodology_zh":"粉尘分级排放（由计算得出）"},{"_id":"6a5dc9c1f1c10c8ce825f3f3","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia dioksynopodobnych PCB","methodology_en":"Sampling for determination of the concentration of dioxin-like PCB","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia dioksynopodobnych PCB","reference":"PN-EN 1948-4+A1:2014-3","norm_bases":["PN-EN 1948-4+A1:2014-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia dioksynopodobnych PCB PN-EN 1948-4+A1:2014-3 Gazy odlotowe Pobieranie probek do oznaczania stezenia dioksynopodobnych PCB PN-EN 1948-4+A1:2014-3","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentration of dioxin-like PCB PN-EN 1948-4+A1:2014-3","search_zh":"废气 PN-EN 1948-4+A1:2014-3","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3f4","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja PCB (z obliczeń)","methodology_en":"PCB emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja PCB (z obliczeń)","reference":"PN-EN 1948-4+A1:2014-3","norm_bases":["PN-EN 1948-4+A1:2014-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja PCB (z obliczeń) PN-EN 1948-4+A1:2014-3 Gazy odlotowe Emisja PCB (z obliczen) PN-EN 1948-4+A1:2014-3","categories":["environment"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases PCB emission (calculated) PN-EN 1948-4+A1:2014-3","search_zh":"废气 PCB 排放（由计算得出） PN-EN 1948-4+A1:2014-3","test_object_zh":"废气","methodology_zh":"PCB 排放（由计算得出）"},{"_id":"6a5dc9c1f1c10c8ce825f3f5","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania bromowanych związków opóźniających zapłon BFR","methodology_en":"Sampling for determination of brominated flame retardants BFR","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania bromowanych związków opóźniających zapłon BFR","reference":"PN-EN 1948-1:2006 | Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r.","norm_bases":["PN-EN 1948-1:2006","Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania bromowanych związków opóźniających zapłon BFR PN-EN 1948-1:2006 | Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r. Gazy odlotowe Pobieranie probek do oznaczania bromowanych zwiazkow opozniajacych zaplon BFR PN-EN 1948-1:2006 | Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r.","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of brominated flame retardants BFR PN-EN 1948-1:2006 | Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r.","search_zh":"废气 PN-EN 1948-1:2006 | Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r.","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3f6","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja bromowanych związków opóźniających zapłon BFR (z obliczeń)","methodology_en":"Emission of brominated flame retardants BFR (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja bromowanych związków opóźniających zapłon BFR (z obliczeń)","reference":"PN-EN 1948-1:2006 | Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r.","norm_bases":["PN-EN 1948-1:2006","Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja bromowanych związków opóźniających zapłon BFR (z obliczeń) PN-EN 1948-1:2006 | Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r. Gazy odlotowe Emisja bromowanych zwiazkow opozniajacych zaplon BFR (z obliczen) PN-EN 1948-1:2006 | Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r.","categories":["environment"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of brominated flame retardants BFR (calculated) PN-EN 1948-1:2006 | Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r.","search_zh":"废气 PN-EN 1948-1:2006 | Instrukcja robocza IR-60 wydanie 1 z dnia 27.02.2025 r.","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3f7","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania polibromowanych dibenzo-p-dioksyn i furanów PBDD/F","methodology_en":"Sampling for determination of polybrominated dibenzo-p-dioxins and furans PBDD/F","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania polibromowanych dibenzo-p-dioksyn i furanów PBDD/F","reference":"PN-EN 1948-1:2006 | Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r.","norm_bases":["PN-EN 1948-1:2006","Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania polibromowanych dibenzo-p-dioksyn i furanów PBDD/F PN-EN 1948-1:2006 | Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r. Gazy odlotowe Pobieranie probek do oznaczania polibromowanych dibenzo-p-dioksyn i furanow PBDD/F PN-EN 1948-1:2006 | Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r.","categories":["other"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of polybrominated dibenzo-p-dioxins and furans PBDD/F PN-EN 1948-1:2006 | Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r.","search_zh":"废气 PN-EN 1948-1:2006 | Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r.","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3f8","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja polibromowanych dibenzo-pdioksyn i furanów PBDD/F (z obliczeń)","methodology_en":"Emission of polybrominated dibenzo-p-dioxins and furans PBDD/F (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja polibromowanych dibenzo-pdioksyn i furanów PBDD/F (z obliczeń)","reference":"PN-EN 1948-1:2006 | Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r.","norm_bases":["PN-EN 1948-1:2006","Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja polibromowanych dibenzo-pdioksyn i furanów PBDD/F (z obliczeń) PN-EN 1948-1:2006 | Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r. Gazy odlotowe Emisja polibromowanych dibenzo-pdioksyn i furanow PBDD/F (z obliczen) PN-EN 1948-1:2006 | Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r.","categories":["environment"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of polybrominated dibenzo-p-dioxins and furans PBDD/F (calculated) PN-EN 1948-1:2006 | Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r.","search_zh":"废气 PN-EN 1948-1:2006 | Instrukcja robocza IR-61 wydanie 1 z dnia 27.02.2025 r.","test_object_zh":"废气"},{"_id":"6a5dc9c1f1c10c8ce825f3f9","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie: NH3, N2O","methodology_en":"Calibration of AMS (QAL2) for: NH3, N2O","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kalibracja AMS (QAL2) w zakresie: NH3, N2O","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: NH3, N2O PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: NH3, N2O PN-EN 14181:2015-02","categories":["metrology"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Calibration of AMS (QAL2) for: NH3, N2O PN-EN 14181:2015-02","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c1f1c10c8ce825f3fa","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Roczne badania kontrolne (AST) w zakresie: NH3, N2O","methodology_en":"Annual surveillance tests (AST) for: NH3, N2O","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Roczne badania kontrolne (AST) w zakresie: NH3, N2O","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Roczne badania kontrolne (AST) w zakresie: NH3, N2O PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Roczne badania kontrolne (AST) w zakresie: NH3, N2O PN-EN 14181:2015-02","categories":["other"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Annual surveillance tests (AST) for: NH3, N2O PN-EN 14181:2015-02","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c1f1c10c8ce825f3fb","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie amoniaku","methodology_en":"Ammonia concentration","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 100) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie amoniaku\nZakres (1,0 – 100) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie amoniaku\nZakres (1,0 – 100) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Automatyczne Systemy, Monitoringu (AMS) Stezenie amoniaku\nZakres (1,0 – 100) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Ammonia concentration Spectrophotometric method Range PN-EN ISO 21877:2020-03","parameters_zh":[{"name":"范围","range":"(1,0 – 100) mg/m3"}],"search_zh":"自动测量系统（AMS） 氨浓度 分光光度法 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氨浓度"},{"_id":"6a5dc9c1f1c10c8ce825f3fc","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie podtlenku azotu (N2O)","methodology_en":"Nitrous oxide (N2O) concentration","parameters":[{"name":"Zakres","range":"(1,4 – 400) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,4 – 400) mg/m3"}],"technique":"Metoda spektrometrii niedyspersyjnej w podczerwieni (NDIR)","techniques":["Metoda spektrometrii niedyspersyjnej w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie podtlenku azotu (N2O)\nZakres (1,4 – 400) mg/m3\nMetoda spektrometrii niedyspersyjnej w podczerwieni (NDIR)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie podtlenku azotu (N2O)\nZakres (1,4 – 400) mg/m3\nMetoda spektrometrii niedyspersyjnej w podczerwieni (NDIR) PN-EN ISO 21258:2010 Automatyczne Systemy, Monitoringu (AMS) Stezenie podtlenku azotu (N2O)\nZakres (1,4 – 400) mg/m3\nMetoda spektrometrii niedyspersyjnej w podczerwieni (NDIR) PN-EN ISO 21258:2010","categories":["other"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Nitrous oxide (N2O) concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN ISO 21258:2010","parameters_zh":[{"name":"范围","range":"(1,4 – 400) mg/m3"}],"search_zh":"自动测量系统（AMS） 范围 PN-EN ISO 21258:2010","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c1f1c10c8ce825f3fd","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","methodology_en":"Sampling for determination of total mercury concentration","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"technique_en":"Aspiration method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej\nMetoda aspiracyjna","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Pobieranie próbek do oznaczania stężenia rtęci ogólnej\nMetoda aspiracyjna PN-EN 13211+AC:2006 Automatyczne Systemy, Monitoringu (AMS) Pobieranie probek do oznaczania stezenia rteci ogolnej\nMetoda aspiracyjna PN-EN 13211+AC:2006","categories":["other"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Sampling for determination of total mercury concentration Aspiration method PN-EN 13211+AC:2006","search_zh":"自动测量系统（AMS） 总汞浓度测定采样 抽气法 PN-EN 13211+AC:2006","test_object_zh":"自动测量系统（AMS）","technique_zh":"抽气法","methodology_zh":"总汞浓度测定采样"},{"_id":"6a5dc9c1f1c10c8ce825f3fe","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","test_object_en":"Waste gas dedusting equipment","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,001 - 100) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,001 - 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,001 - 100) g/m3\nMetoda grawimetryczna","reference":"PN-87/M-34129 - metoda A | PN-Z-04030-7:1994","norm_bases":["PN-87/M-34129 - metoda A","PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia odpylające gazy odlotowe Stężenie pyłu\nZakres (0,001 - 100) g/m3\nMetoda grawimetryczna PN-87/M-34129 - metoda A | PN-Z-04030-7:1994 Urzadzenia odpylajace gazy odlotowe Stezenie pylu\nZakres (0,001 - 100) g/m3\nMetoda grawimetryczna PN-87/M-34129 - metoda A | PN-Z-04030-7:1994","categories":["other"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gas dedusting equipment Dust concentration Gravimetric method Range PN-87/M-34129 - metoda A | PN-Z-04030-7:1994","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 - 100) g/m3"}],"search_zh":"废气除尘设备 粉尘浓度 重量法 范围 PN-87/M-34129 - metoda A | PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气除尘设备"},{"_id":"6a5dc9c1f1c10c8ce825f3ff","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","test_object_en":"Waste gas dedusting equipment","methodology":"Skuteczność odpylania (z obliczeń)","methodology_en":"Dust removal efficiency (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność odpylania (z obliczeń)","reference":"PN-87/M-34129 - metoda A | PN-Z-04030-7:1994","norm_bases":["PN-87/M-34129 - metoda A","PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia odpylające gazy odlotowe Skuteczność odpylania (z obliczeń) PN-87/M-34129 - metoda A | PN-Z-04030-7:1994 Urzadzenia odpylajace gazy odlotowe Skutecznosc odpylania (z obliczen) PN-87/M-34129 - metoda A | PN-Z-04030-7:1994","categories":["other"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gas dedusting equipment Dust removal efficiency (calculated) PN-87/M-34129 - metoda A | PN-Z-04030-7:1994","search_zh":"废气除尘设备 除尘效率（由计算得出） PN-87/M-34129 - metoda A | PN-Z-04030-7:1994","test_object_zh":"废气除尘设备","methodology_zh":"除尘效率（由计算得出）"},{"_id":"6a5dc9c1f1c10c8ce825f400","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A LAeq","methodology_en":"A-weighted equivalent sound level LAeq","parameters":[{"name":"Zakres","range":"(25 - 135) dB"}],"parameters_en":[{"name":"Range","range":"(25 - 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A LAeq\nZakres (25 - 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A LAeq\nZakres (25 - 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A LAeq\nZakres (25 - 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level LAeq Direct measurement method Range Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","parameters_zh":[{"name":"范围","range":"(25 - 135) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 直接测量法 范围 Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5dc9c1f1c10c8ce825f401","lab_id":"69ad52a3de79e566650fb466","country":"PL","accr_number":"AB 872","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia wyrażony wskaźnikami, LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound level for the reference time expressed by the indicators, LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia wyrażony wskaźnikami, LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia wyrażony wskaźnikami, LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia wyrazony wskaznikami, LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level for the reference time expressed by the indicators, LAeqD and LAeqN (calculated) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"}],"has_pdf":true}