🇵🇱 LABORATORIUM BADANIA ŚRODOWISKA PRACY PL
Environment
LABORATORIUM BADANIA ŚRODOWISKA PRACY is a laboratory accredited by PCA under number AB 870 (Radom, Poland). Its accreditation scope covers 22 test methods in the following areas: Environment. Test objects include: Workplace environment − air, Workplace environment - hearing protectors, Workplace environment – cold microclimate, Workplace environment – hot microclimate. Most frequently used techniques: Direct measurement method, Gravimetric method, Electrochemical method.
At a glance
- Accreditation number: PCA AB 870
- Methods in scope: 22
- Types of test objects: 9
- Techniques used: 4
- City: Radom, Poland
- Accreditation number
- AB 870
- Accreditation body
- PCA
- Address
- Tomasz Śpilski, ul. Biznesowa 2 lok. 3, 26-600 Radom
- City
- Radom, Poland
What this laboratory tests (9)
- Workplace environment − air — 6 methods
- Workplace environment - hearing protectors — 2 methods
- Workplace environment – cold microclimate — 2 methods
- Workplace environment – hot microclimate — 2 methods
- Workplace environment – moderate microclimate — 2 methods
- Workplace environment − hand-arm vibration — 2 methods
- Workplace environment − indoor electric lighting — 2 methods
- Workplace environment − noise — 2 methods
- Workplace environment − whole-body vibration — 2 methods
Analytical techniques used (4)
- Direct measurement method — 7 methods
- Gravimetric method — 2 methods
- Electrochemical method — 1 method
- Personal dosimetry method — 1 method
Accreditation scope — test methods (22)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment − air | Sampling for occupational exposure assessment to: − dust agents inhalable fraction respirable fraction − metals and their compounds, including: inhalable fraction respirable fraction − organic substances, including: inhalable fraction − inorganic substances, including: respirable fraction | Personal dosimetry method | PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 | |
| 2 | Workplace environment − air | Exposure index (calculated) | PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 | ||
| 3 | Workplace environment − air | Concentration of harmful dust agents – inhalable fraction Range (0,18 - 17,36) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 4 | Workplace environment − air | Concentration of harmful dust agents – respirable fraction Range (0,16 - 7,31) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 5 | Workplace environment − air | Gas concentration – carbon monoxide Range (2,24 - 174) mg/m3 |
Electrochemical method | Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r. | |
| 6 | Workplace environment − air | Exposure indices (calculated) | Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r. | ||
| 7 | Workplace environment − indoor electric lighting | Illuminance Range (0,5 - 10000) lx |
Direct measurement method | PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r. | |
| 8 | Workplace environment − indoor electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r. | ||
| 9 | Workplace environment – hot microclimate | Air temperature Range (15 - 60) °C Natural wet bulb temperature Range (15 - 50) °C Black globe temperature Range (15 - 60) °C |
Direct measurement method | PN-EN ISO 7243: 2018-01 | |
| 10 | Workplace environment – hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243: 2018-01 | ||
| 11 | Workplace environment – moderate microclimate | Air temperature Range (10 - 30) °C Black globe temperature Range (10 - 40) °C Air humidity Range (25 - 75) % Air velocity Range (0,15 - 1,0) m/s |
Direct measurement method | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | |
| 12 | Workplace environment – moderate microclimate | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | ||
| 13 | Workplace environment – cold microclimate | Air temperature Range (-20 - 10) °C Black globe temperature Range (-20 - 15) °C Air humidity Range (25 - 75) % Air velocity Range (0,4 - 1,0) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 14 | Workplace environment – cold microclimate | IREQmin index, IREQneutr index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 15 | Workplace environment − noise | A-weighted equivalent sound level Maximum A-weighted sound level C-weighted peak sound level Range (35 - 135) dB |
Direct measurement method | PN-EN 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11 | |
| 16 | Workplace environment − noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-EN 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11 | ||
| 17 | Workplace environment - hearing protectors | Equivalent sound pressure level in octave frequency bands: Range (63 - 8000) Hz Range (35 - 135) dB A-weighted equivalent sound pressure level C-weighted equivalent sound pressure level |
Direct measurement method | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2002 | PN-EN ISO 4869-2:2018-12 | |
| 18 | Workplace environment - hearing protectors | A-weighted sound level under hearing protectors (calculated) | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2002 | PN-EN ISO 4869-2:2018-12 | ||
| 19 | Workplace environment − whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,02 - 50) ms-2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 20 | Workplace environment − whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 21 | Workplace environment − hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,2 - 50) ms-2 Direct measurement method |
PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-1:2004+A1:2015-11 | ||
| 22 | Workplace environment − hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-1:2004+A1:2015-11 | ||
Reference standards (21)
PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r.
PN-EN 01307:1994
PN-EN 14253+A1:2011
PN-EN 458:2016-06
PN-EN ISO 11079:2008
PN-EN ISO 4869-2:2002
PN-EN ISO 4869-2:2018-12
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-1:2004+A1:2015-11
PN-EN ISO 5349-2:2004
PN-EN ISO 7243: 2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11
PN-Z-04008-7:2002
PN-Z-04008-7:2002/Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r.