{"lab":{"_id":"69ad52a3de79e566650fb462","accr_number":"AB 870","country":"PL","accr_body":"PCA","address":"Tomasz Śpilski, ul. Biznesowa 2 lok. 3, 26-600 Radom","categories":["environment"],"city":"Radom","imported_at":"2026-03-08T10:42:43.265Z","methods_count":22,"name":"LABORATORIUM BADANIA ŚRODOWISKA PRACY","parse_status":"parsed","parse_version":3,"pdf_files":["AB_870.pdf"],"scope_summary":"","search_text":"laboratorium badania środowiska pracy tomasz śpilski, ul. biznesowa 2 lok. 3, 26-600 radom environment other materials metrology pharma electronics","status":"active","updated_at":"2026-03-08T14:51:45.582Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:45.582Z","location":{"type":"Point","coordinates":[21.1471,51.4027]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20870,podmiot.html","fields_of_testing":[{"codes":"A/19","pl":"Badania akustyczne i drgań: środki ochrony osobistej (ochronniki słuchu)","en":"Acoustic and vibration tests: personal protection equipment"},{"codes":"C/33/P; G/33; N/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests and sampling - working environment (harmful factors – air), Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, mikroklimat, drgania) / Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors - noise, lighting, microclimate, vibration) Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze) / Tests of physical properties and sampling - working environment (harmful factors - air)"}],"issue":{"no":"20","date":"24.11.2025"},"parse_date":"2026-07-20T07:09:52.937Z","parse_source":"script-pdfplumber","map_coord":[51.391261,21.146385],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":22,"materials":1},"category_scores":{"environment":21.04,"materials":0.04},"has_zh":true},"methods":[{"_id":"6a5dc9c0f1c10c8ce825f38f","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na: − czynniki pyłowe frakcja wdychalna frakcja respirabilna − metale i ich związki, w tym: frakcja wdychalna frakcja respirabilna − substancje organiczne, w tym: frakcja wdychalna − substancje nieorganiczne, w tym: frakcja respirabilna","methodology_en":"Sampling for occupational exposure assessment to: − dust agents inhalable fraction respirable fraction − metals and their compounds, including: inhalable fraction respirable fraction − organic substances, including: inhalable fraction − inorganic substances, including: respirable fraction","parameters":[],"parameters_en":[],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"technique_en":"Personal dosimetry method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na: − czynniki pyłowe frakcja wdychalna frakcja respirabilna − metale i ich związki, w tym: frakcja wdychalna frakcja respirabilna − substancje organiczne, w tym: frakcja wdychalna − substancje nieorganiczne, w tym: frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na: − czynniki pyłowe frakcja wdychalna frakcja respirabilna − metale i ich związki, w tym: frakcja wdychalna frakcja respirabilna − substancje organiczne, w tym: frakcja wdychalna − substancje nieorganiczne, w tym: frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na: − czynniki pylowe frakcja wdychalna frakcja respirabilna − metale i ich zwiazki, w tym: frakcja wdychalna frakcja respirabilna − substancje organiczne, w tym: frakcja wdychalna − substancje nieorganiczne, w tym: frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Sampling for occupational exposure assessment to: − dust agents inhalable fraction respirable fraction − metals and their compounds, including: inhalable fraction respirable fraction − organic substances, including: inhalable fraction − inorganic substances, including: respirable fraction Personal dosimetry method PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","search_zh":"工作环境 − 空气 个体剂量测定法 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9c0f1c10c8ce825f390","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9c0f1c10c8ce825f391","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters":[{"name":"Zakres","range":"(0,18 - 17,36) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,18 - 17,36) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres (0,18 - 17,36) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres (0,18 - 17,36) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres (0,18 - 17,36) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of harmful dust agents – inhalable fraction Gravimetric method Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","parameters_zh":[{"name":"范围","range":"(0,18 - 17,36) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 可吸入组分 重量法 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a5dc9c0f1c10c8ce825f392","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters":[{"name":"Zakres","range":"(0,16 - 7,31) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,16 - 7,31) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres (0,16 - 7,31) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres (0,16 - 7,31) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres (0,16 - 7,31) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of harmful dust agents – respirable fraction Gravimetric method Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","parameters_zh":[{"name":"范围","range":"(0,16 - 7,31) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a5dc9c0f1c10c8ce825f393","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie gazów – tlenek węgla","methodology_en":"Gas concentration – carbon monoxide","parameters":[{"name":"Zakres","range":"(2,24 - 174) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,24 - 174) mg/m3"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie gazów – tlenek węgla\nZakres (2,24 - 174) mg/m3\nMetoda elektrochemiczna","reference":"Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r.","norm_bases":["Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie gazów – tlenek węgla\nZakres (2,24 - 174) mg/m3\nMetoda elektrochemiczna Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r. Srodowisko pracy − powietrze Stezenie gazow – tlenek wegla\nZakres (2,24 - 174) mg/m3\nMetoda elektrochemiczna Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r.","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Gas concentration – carbon monoxide Electrochemical method Range Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r.","parameters_zh":[{"name":"范围","range":"(2,24 - 174) mg/m3"}],"search_zh":"工作环境 − 空气 电化学法 范围 Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r.","technique_zh":"电化学法","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9c0f1c10c8ce825f394","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Wskaźniki narażenia (z obliczeń)","methodology_en":"Exposure indices (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r.","norm_bases":["Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Wskaźniki narażenia (z obliczeń) Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r. Srodowisko pracy − powietrze Wskazniki narazenia (z obliczen) Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r.","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Exposure indices (calculated) Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r.","search_zh":"工作环境 − 空气 暴露指数（计算值） Procedura Badawcza PB-04, wydanie 10 z dnia 03.01.2024 r.","test_object_zh":"工作环境 − 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a5dc9c0f1c10c8ce825f395","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment − indoor electric lighting","methodology":"Natężenie oświetlenia","methodology_en":"Illuminance","parameters":[{"name":"Zakres","range":"(0,5 - 10000) lx"}],"parameters_en":[{"name":"Range","range":"(0,5 - 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r.","norm_bases":["PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (0,5 - 10000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (0,5 - 10000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r.","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r.","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 10000) lx"}],"search_zh":"工作场所环境 − 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a5dc9c0f1c10c8ce825f396","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment − indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r.","norm_bases":["PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r.","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r.","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 − 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03 Procedura Badawcza PB-03, wydanie 4 z dnia 30.08.2017 r.","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a5dc9c0f1c10c8ce825f397","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","test_object_en":"Workplace environment – hot microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(15 - 60) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(15 - 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(15 - 60) °C"}],"parameters_en":[{"name":"Range","range":"(15 - 60) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(15 - 50) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(15 - 60) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15 - 60) °C\nTemperatura wilgotna naturalna\nZakres (15 - 50) °C\nTemperatura poczernionej kuli\nZakres (15 - 60) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243: 2018-01","norm_bases":["PN-EN ISO 7243: 2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (15 - 60) °C\nTemperatura wilgotna naturalna\nZakres (15 - 50) °C\nTemperatura poczernionej kuli\nZakres (15 - 60) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243: 2018-01 Srodowisko pracy – mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (15 - 60) °C\nTemperatura wilgotna naturalna\nZakres (15 - 50) °C\nTemperatura poczernionej kuli\nZakres (15 - 60) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243: 2018-01","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243: 2018-01","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(15 - 60) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(15 - 50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(15 - 60) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243: 2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a5dc9c0f1c10c8ce825f398","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","test_object_en":"Workplace environment – hot microclimate","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","methodology_en":"WBGT index, WBGTeff index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243: 2018-01","norm_bases":["PN-EN ISO 7243: 2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243: 2018-01 Srodowisko pracy – mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243: 2018-01","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243: 2018-01","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243: 2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a5dc9c0f1c10c8ce825f399","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","test_object_en":"Workplace environment – moderate microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(10 - 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 40) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 - 75) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 1,0) m/s"}],"parameters_en":[{"name":"Range","range":"(10 - 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 - 40) °C"},{"name":"Air humidity"},{"name":"Range","range":"(25 - 75) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 40) °C\nWilgotność powietrza\nZakres (25 - 75) %\nPrędkość powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 40) °C\nWilgotność powietrza\nZakres (25 - 75) %\nPrędkość powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 40) °C\nWilgotnosc powietrza\nZakres (25 - 75) %\nPredkosc powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 - 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 - 40) °C"},{"name":"空气湿度"},{"name":"范围","range":"(25 - 75) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 1,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a5dc9c0f1c10c8ce825f39a","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","test_object_en":"Workplace environment – moderate microclimate","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","methodology_en":"PMV index, PPD index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a5dc9c0f1c10c8ce825f39b","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","test_object_en":"Workplace environment – cold microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(-20 - 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-20 - 15) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 - 75) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,4 - 1,0) m/s"}],"parameters_en":[{"name":"Range","range":"(-20 - 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-20 - 15) °C"},{"name":"Air humidity"},{"name":"Range","range":"(25 - 75) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,4 - 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-20 - 10) °C\nTemperatura poczernionej kuli\nZakres (-20 - 15) °C\nWilgotność powietrza\nZakres (25 - 75) %\nPrędkość powietrza\nZakres (0,4 - 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-20 - 10) °C\nTemperatura poczernionej kuli\nZakres (-20 - 15) °C\nWilgotność powietrza\nZakres (25 - 75) %\nPrędkość powietrza\nZakres (0,4 - 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-20 - 10) °C\nTemperatura poczernionej kuli\nZakres (-20 - 15) °C\nWilgotnosc powietrza\nZakres (25 - 75) %\nPredkosc powietrza\nZakres (0,4 - 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-20 - 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-20 - 15) °C"},{"name":"空气湿度"},{"name":"范围","range":"(25 - 75) %"},{"name":"空气流速"},{"name":"范围","range":"(0,4 - 1,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a5dc9c0f1c10c8ce825f39c","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","test_object_en":"Workplace environment – cold microclimate","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutr, Wskaźnik twc (z obliczeń)","methodology_en":"IREQmin index, IREQneutr index, twc index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutr, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutr, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutr, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – cold microclimate IREQmin index, IREQneutr index, twc index (calculated) PN-EN ISO 11079:2008","search_zh":"工作场所环境 — 低温微气候 PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a5dc9c0f1c10c8ce825f39d","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level C-weighted peak sound level","parameters":[{"name":"Zakres","range":"(35 - 135) dB"}],"parameters_en":[{"name":"Range","range":"(35 - 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C\nZakres (35 - 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11","norm_bases":["PN-EN 01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C\nZakres (35 - 135) dB\nMetoda pomiarowa bezpośrednia PN-EN 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Szczytowy poziom dzwieku C\nZakres (35 - 135) dB\nMetoda pomiarowa bezposrednia PN-EN 01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metod obejmujacych Strategie 2 i 3 - pkt 10 i pkt 11","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level C-weighted peak sound level Direct measurement method Range PN-EN 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11","parameters_zh":[{"name":"范围","range":"(35 - 135) dB"}],"search_zh":"工作环境 − 噪声 A 计权等效声级 A 计权最大声级 C 计权峰值声级 直接测量法 范围 PN-EN 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声","methodology_zh":"A 计权等效声级 A 计权最大声级 C 计权峰值声级"},{"_id":"6a5dc9c0f1c10c8ce825f39e","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Poziom ekspozycji na hałas odniesiony do:","methodology_en":"Noise exposure level referred to:","parameters":[{"name":"8 godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8 godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-EN 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11","norm_bases":["PN-EN 01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8 godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-EN 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11 Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8 godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-EN 01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metod obejmujacych Strategie 2 i 3 - pkt 10 i pkt 11","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-EN 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作环境 − 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-EN 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 i 3 - pkt 10 i pkt 11","test_object_zh":"工作环境 − 噪声"},{"_id":"6a5dc9c0f1c10c8ce825f39f","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy - ochronniki słuchu","test_object_en":"Workplace environment - hearing protectors","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach częstotliwościowych oktawowych:","methodology_en":"Equivalent sound pressure level in octave frequency bands:","parameters":[{"name":"Zakres","range":"(63 - 8000) Hz"},{"name":"Zakres","range":"(35 - 135) dB"},{"name":"Równoważny poziom dźwięku A Równoważny poziom dźwięku C"}],"parameters_en":[{"name":"Range","range":"(63 - 8000) Hz"},{"name":"Range","range":"(35 - 135) dB"},{"name":"A-weighted equivalent sound pressure level C-weighted equivalent sound pressure level"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach częstotliwościowych oktawowych:\nZakres:\nZakres (63 - 8000) Hz\nZakres (35 - 135) dB\nRównoważny poziom dźwięku A Równoważny poziom dźwięku C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 458:2016-06 | PN-EN ISO 4869-2:2002 | PN-EN ISO 4869-2:2018-12","norm_bases":["PN-EN 458:2016-06","PN-EN ISO 4869-2:2002","PN-EN ISO 4869-2:2018-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - ochronniki słuchu Równoważny poziom ciśnienia akustycznego w pasmach częstotliwościowych oktawowych:\nZakres:\nZakres (63 - 8000) Hz\nZakres (35 - 135) dB\nRównoważny poziom dźwięku A Równoważny poziom dźwięku C\nMetoda pomiarowa bezpośrednia PN-EN 458:2016-06 | PN-EN ISO 4869-2:2002 | PN-EN ISO 4869-2:2018-12 Srodowisko pracy - ochronniki sluchu Rownowazny poziom cisnienia akustycznego w pasmach czestotliwosciowych oktawowych:\nZakres:\nZakres (63 - 8000) Hz\nZakres (35 - 135) dB\nRownowazny poziom dzwieku A Rownowazny poziom dzwieku C\nMetoda pomiarowa bezposrednia PN-EN 458:2016-06 | PN-EN ISO 4869-2:2002 | PN-EN ISO 4869-2:2018-12","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hearing protectors Equivalent sound pressure level in octave frequency bands: Direct measurement method Range Range A-weighted equivalent sound pressure level C-weighted equivalent sound pressure level PN-EN 458:2016-06 | PN-EN ISO 4869-2:2002 | PN-EN ISO 4869-2:2018-12","parameters_zh":[{"name":"范围","range":"(63 - 8000) Hz"},{"name":"范围","range":"(35 - 135) dB"},{"name":"A 计权等效声级 C 计权等效声级"}],"search_zh":"直接测量法 范围 范围 A 计权等效声级 C 计权等效声级 PN-EN 458:2016-06 | PN-EN ISO 4869-2:2002 | PN-EN ISO 4869-2:2018-12","technique_zh":"直接测量法"},{"_id":"6a5dc9c0f1c10c8ce825f3a0","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy - ochronniki słuchu","test_object_en":"Workplace environment - hearing protectors","methodology":"Poziom dźwięku A pod ochronnikami słuchu (z obliczeń)","methodology_en":"A-weighted sound level under hearing protectors (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom dźwięku A pod ochronnikami słuchu (z obliczeń)","reference":"PN-EN 458:2016-06 | PN-EN ISO 4869-2:2002 | PN-EN ISO 4869-2:2018-12","norm_bases":["PN-EN 458:2016-06","PN-EN ISO 4869-2:2002","PN-EN ISO 4869-2:2018-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - ochronniki słuchu Poziom dźwięku A pod ochronnikami słuchu (z obliczeń) PN-EN 458:2016-06 | PN-EN ISO 4869-2:2002 | PN-EN ISO 4869-2:2018-12 Srodowisko pracy - ochronniki sluchu Poziom dzwieku A pod ochronnikami sluchu (z obliczen) PN-EN 458:2016-06 | PN-EN ISO 4869-2:2002 | PN-EN ISO 4869-2:2018-12","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hearing protectors A-weighted sound level under hearing protectors (calculated) PN-EN 458:2016-06 | PN-EN ISO 4869-2:2002 | PN-EN ISO 4869-2:2018-12"},{"_id":"6a5dc9c0f1c10c8ce825f3a1","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment − whole-body vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters":[{"name":"Zakres","range":"(0,02 - 50) ms-2"}],"parameters_en":[{"name":"Range","range":"(0,02 - 50) ms-2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,02 - 50) ms-2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,02 - 50) ms-2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,02 - 50) ms-2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,02 - 50) ms-2"}],"search_zh":"工作场所环境 − 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 全身振动"},{"_id":"6a5dc9c0f1c10c8ce825f3a2","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment − whole-body vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011","search_zh":"工作场所环境 − 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 − 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）"},{"_id":"6a5dc9c0f1c10c8ce825f3a3","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment − hand-arm vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters":[{"name":"Zakres","range":"(0,2 - 50) ms-2"},{"name":"M e t o d a p o m i a r o w a b e z p o ś r e d n i a"}],"parameters_en":[{"name":"Range","range":"(0,2 - 50) ms-2"},{"name":"Direct measurement method"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,2 - 50) ms-2\nM e t o d a p o m i a r o w a b e z p o ś r e d n i a","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-1:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-1:2004+A1:2015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,2 - 50) ms-2\nM e t o d a p o m i a r o w a b e z p o ś r e d n i a PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-1:2004+A1:2015-11 Srodowisko pracy − drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres:\nZakres (0,2 - 50) ms-2\nM e t o d a p o m i a r o w a b e z p o s r e d n i a PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-1:2004+A1:2015-11","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Range Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-1:2004+A1:2015-11","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,2 - 50) ms-2"},{"name":"M e t o d a p o m i a r o w a b e z p o ś r e d n i a"}],"search_zh":"工作场所环境 − 手传振动 频率计权振动加速度有效值 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-1:2004+A1:2015-11","test_object_zh":"工作场所环境 − 手传振动"},{"_id":"6a5dc9c0f1c10c8ce825f3a4","lab_id":"69ad52a3de79e566650fb462","country":"PL","accr_number":"AB 870","accr_body":"PCA","test_object":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment − hand-arm vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-1:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-1:2004+A1:2015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-1:2004+A1:2015-11 Srodowisko pracy − drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-1:2004+A1:2015-11","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-1:2004+A1:2015-11","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","search_zh":"工作场所环境 − 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-1:2004+A1:2015-11","test_object_zh":"工作场所环境 − 手传振动"}],"has_pdf":true}