🇵🇱 UNIWERSYTET MORSKI W GDYNI PL

PCA AB 848 • Gdynia, Poland • 34 methods

EnvironmentAutomotiveElectronics & EMC

UNIWERSYTET MORSKI W GDYNI is a laboratory accredited by PCA under number AB 848 (Gdynia, Poland). Its accreditation scope covers 34 test methods in the following areas: Environment, Automotive, Electronics & EMC. Test objects include: Environment – electromagnetic field in the vicinity of radar instal…, Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment − electromagnetic field from equipment used i…, Workplace environment − electromagnetic field originating from indu…. Most frequently used techniques: Direct measurement method.

At a glance

  • Accreditation number: PCA AB 848
  • Methods in scope: 34
  • Types of test objects: 10
  • Techniques used: 1
  • City: Gdynia, Poland
Accreditation number
AB 848
Accreditation body
PCA
Address
INSTYTUT MORSKI, ul. Morska 81-87, 81-225 Gdynia, LABORATORIUM ELEKTRONIKI MORSKIEJ, ul. Roberta de Plelo 20
City
Gdynia, Poland

What this laboratory tests (10)

Analytical techniques used (1)

Laboratory locations

Certificate information

Issue date
27.07.2026
Issue no.
26

Accreditation scope — test methods (34)

No. Test object Methodology / Parameters Technique Reference document
Laboratorium Elektroniki Morskiej
1 Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Electric field strength:
in the frequency range from 10 Hz do 400 kHz Range (0,1 – 50000) V/m in the frequency range from 0,1 MHz do 18000 MHz Range (0,5 – 1000) V/m in the frequency range from 18 GHz do 90 GHz Range (2 – 1000) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01
2 Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Magnetic field strength:
in the frequency range from 100 kHz do 35 MHz Range (0,01 – 16) A/m in the frequency range from 300 kHz do 60 MHz Range (0,01 – 20) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 1) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01
3 Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Magnetic flux density:
in the frequency range 0 Hz Range (0,050 – 1200) mT in the frequency range from 10 Hz do 400 kHz Range 30 nT – 19 mT
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01
4 Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Magnetic field strength:
in the frequency range from 10 Hz do 400 kHz from 1 GHz do 3 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01
5 Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems Electric field strength:
in the frequency range from 10 Hz do 400 kHz Range (0,1 – 50000) V/m in the frequency range from 0,1 MHz do 18000 MHz Range (0,5 – 1000) V/m in the frequency range from 18 GHz do 90 GHz Range (2 – 1000) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01
6 Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range from 100 kHz do 35 MHz Range (0,01 – 16) A/m in the frequency range from 300 kHz do 60 MHz Range (0,01 – 20) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 1) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01
7 Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems Magnetic flux density:
in the frequency range 0 Hz Range (0,050 – 1200) mT in the frequency range from 10 Hz do 400 kHz Range 30 nT – 19 mT
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01
8 Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems Magnetic field strength:
in the frequency range from 10 Hz do 400 kHz from 1 GHz do 3 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01
9 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Electric field strength:
in the frequency range from 10 Hz do 400 kHz Range (0,1 – 50000) V/m in the frequency range from 0,1 MHz do 18000 MHz Range (0,5 – 1000) V/m in the frequency range from 18 GHz do 90 GHz Range (2 – 1000) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01
10 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic field strength:
in the frequency range from 100 kHz do 35 MHz Range (0,01 – 16) A/m in the frequency range from 300 kHz do 60 MHz Range (0,01 – 20) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 1) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01
11 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic flux density:
in the frequency range 0 Hz Range (0,050 – 1200) mT in the frequency range from 10 Hz do 400 kHz Range 30 nT – 19 mT
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01
12 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic field strength:
in the frequency range from 10 Hz do 400 kHz from 1 GHz do 3 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01
13 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Electric field strength:
in the frequency range from 45 Hz do 55 Hz Range (1 – 50000) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
14 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic field strength:
in the frequency range from 45 Hz do 55 Hz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
15 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic flux density:
in the frequency range from 45 Hz do 55 Hz Range 30 nT – 19 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
16 Workplace environment - electromagnetic field in the work space during the use of magnetotherapy devices (simplified method) Magnetic field strength:
in the frequency range from 20 Hz do 55 Hz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
17 Workplace environment - electromagnetic field in the work space during the use of magnetotherapy devices (simplified method) Magnetic flux density:
in the frequency range from 20 Hz do 55 Hz Range 30 nT – 19 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
18 Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Electric field strength:
in the frequency range from 0,1 MHz do 18000 MHz Range (0,5 – 1000) V/m in the frequency range from 18 GHz do 90 GHz Range (2 – 1000) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
19 Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 100 kHz do 35 MHz Range (0,01 – 16) A/m in the frequency range from 300 kHz do 60 MHz Range (0,01 – 20) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 1) A/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
20 Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength:
in the frequency range from 0,8 GHz do 90 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
21 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength:
in the frequency range 50 Hz Range (1 – 50000) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
22 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density:
in the frequency range 50 Hz Range 30 nT – 19 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
23 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength:
in the frequency range 50 Hz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
24 Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines Electric field strength:
in the frequency range from 10 Hz do 400 kHz Range (1 – 50000) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
25 Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines Magnetic flux density:
in the frequency range 0 Hz Range (0,050 – 1200) mT in the frequency range from 10 Hz do 400 kHz Range 30 nT – 19 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
26 Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines Magnetic field strength:
in the frequency range from 10 Hz do 400 kHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
27 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Electric field strength:
in the frequency range from 0,1 MHz do 18000 MHz Range (0,5 –1000) V/m in the frequency range from 18 GHz do 90 GHz Range (2 – 1000) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
28 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Magnetic field strength:
in the frequency range from 100 kHz do 35 MHz Range (0,01 – 16) A/m in the frequency range from 300 kHz do 60 MHz Range (0,01 – 20) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 1) A/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
29 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Magnetic field strength:
in the frequency range from 10 MHz do 90 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
30 Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Power density:
in the frequency range from 300 MHz do 90 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
31 Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) Electric field strength:
in the frequency range from 0,1 MHz do 18000 MHz Range (0,5 –1000) V/m in the frequency range from 18 GHz do 90 GHz Range (2 – 1000) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
32 Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) Magnetic field strength:
in the frequency range from 100 kHz do 35 MHz Range (0,01 – 16) A/m in the frequency range from 300 kHz do 60 MHz Range (0,01 – 20) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 1) A/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
33 Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) Magnetic field strength:
in the frequency range from 10 MHz do 90 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
34 Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) Power density:
in the frequency range from 300 MHz do 90 GHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)

Reference standards (9)

IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01
IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01
IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20848