🇵🇱 UNIWERSYTET MORSKI W GDYNI PL
EnvironmentElectronics & EMCAutomotive
UNIWERSYTET MORSKI W GDYNI is a laboratory accredited by PCA under number AB 848 (Gdynia, Poland). Its accreditation scope covers 34 test methods in the following areas: Environment, Electronics & EMC, Automotive. Test objects include: Environment – electromagnetic field in the vicinity of radar instal…, Environment – electromagnetic field in the vicinity of radiocommuni…, Workplace environment − electromagnetic field from equipment used i…, Workplace environment − electromagnetic field originating from indu…. Most frequently used techniques: Direct measurement method.
At a glance
- Accreditation number: PCA AB 848
- Methods in scope: 34
- Types of test objects: 10
- Techniques used: 1
- City: Gdynia, Poland
- Accreditation number
- AB 848
- Accreditation body
- PCA
- Address
- INSTYTUT MORSKI, ul. Morska 81-87, 81-225 Gdynia, LABORATORIUM ELEKTRONIKI MORSKIEJ, ul. Roberta de Plelo 20
- City
- Gdynia, Poland
What this laboratory tests (10)
- Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) — 4 methods
- Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) — 4 methods
- Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners — 4 methods
- Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters — 4 methods
- Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems — 4 methods
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 3 methods
- Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines — 3 methods
- Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry — 3 methods
- Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) — 3 methods
- Workplace environment - electromagnetic field in the work space during the use of magnetotherapy devices (simplified method) — 2 methods
Analytical techniques used (1)
- Direct measurement method — 22 methods
Laboratory locations
- LABORATORIUM ELEKTRONIKI MORSKIEJ — ul. Roberta de Plelo 20
Accreditation scope — test methods (34)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium Elektroniki Morskiej | |||||
| 1 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters | Electric field strength: in the frequency range from 10 Hz do 400 kHz Range (0,1 – 50000) V/m in the frequency range from 0,1 MHz do 18000 MHz Range (0,5 – 1000) V/m in the frequency range from 18 GHz do 90 GHz Range (2 – 1000) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 | |
| 2 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters | Magnetic field strength: in the frequency range from 100 kHz do 35 MHz Range (0,01 – 16) A/m in the frequency range from 300 kHz do 60 MHz Range (0,01 – 20) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 1) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 | |
| 3 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters | Magnetic flux density: in the frequency range 0 Hz Range (0,050 – 1200) mT in the frequency range from 10 Hz do 400 kHz Range 30 nT – 19 mT |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 | |
| 4 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters | Magnetic field strength: in the frequency range from 10 Hz do 400 kHz from 1 GHz do 3 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 | ||
| 5 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems | Electric field strength: in the frequency range from 10 Hz do 400 kHz Range (0,1 – 50000) V/m in the frequency range from 0,1 MHz do 18000 MHz Range (0,5 – 1000) V/m in the frequency range from 18 GHz do 90 GHz Range (2 – 1000) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01 | |
| 6 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems | Magnetic field strength: in the frequency range from 100 kHz do 35 MHz Range (0,01 – 16) A/m in the frequency range from 300 kHz do 60 MHz Range (0,01 – 20) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 1) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01 | |
| 7 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems | Magnetic flux density: in the frequency range 0 Hz Range (0,050 – 1200) mT in the frequency range from 10 Hz do 400 kHz Range 30 nT – 19 mT |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01 | |
| 8 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems | Magnetic field strength: in the frequency range from 10 Hz do 400 kHz from 1 GHz do 3 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01 | ||
| 9 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Electric field strength: in the frequency range from 10 Hz do 400 kHz Range (0,1 – 50000) V/m in the frequency range from 0,1 MHz do 18000 MHz Range (0,5 – 1000) V/m in the frequency range from 18 GHz do 90 GHz Range (2 – 1000) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 | |
| 10 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Magnetic field strength: in the frequency range from 100 kHz do 35 MHz Range (0,01 – 16) A/m in the frequency range from 300 kHz do 60 MHz Range (0,01 – 20) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 1) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 | |
| 11 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Magnetic flux density: in the frequency range 0 Hz Range (0,050 – 1200) mT in the frequency range from 10 Hz do 400 kHz Range 30 nT – 19 mT |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 | |
| 12 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Magnetic field strength: in the frequency range from 10 Hz do 400 kHz from 1 GHz do 3 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 | ||
| 13 | Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry | Electric field strength: in the frequency range from 45 Hz do 55 Hz Range (1 – 50000) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 | |
| 14 | Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry | Magnetic field strength: in the frequency range from 45 Hz do 55 Hz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331). |
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 | ||
| 15 | Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry | Magnetic flux density: in the frequency range from 45 Hz do 55 Hz Range 30 nT – 19 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 | |
| 16 | Workplace environment - electromagnetic field in the work space during the use of magnetotherapy devices (simplified method) | Magnetic field strength: in the frequency range from 20 Hz do 55 Hz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331). |
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 | ||
| 17 | Workplace environment - electromagnetic field in the work space during the use of magnetotherapy devices (simplified method) | Magnetic flux density: in the frequency range from 20 Hz do 55 Hz Range 30 nT – 19 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 | |
| 18 | Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) | Electric field strength: in the frequency range from 0,1 MHz do 18000 MHz Range (0,5 – 1000) V/m in the frequency range from 18 GHz do 90 GHz Range (2 – 1000) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 19 | Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) | Magnetic field strength: in the frequency range from 100 kHz do 35 MHz Range (0,01 – 16) A/m in the frequency range from 300 kHz do 60 MHz Range (0,01 – 20) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 1) A/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 20 | Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) | Magnetic field strength: in the frequency range from 0,8 GHz do 90 GHz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331). |
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | ||
| 21 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength: in the frequency range 50 Hz Range (1 – 50000) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 22 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic flux density: in the frequency range 50 Hz Range 30 nT – 19 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 23 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength: in the frequency range 50 Hz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 24 | Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines | Electric field strength: in the frequency range from 10 Hz do 400 kHz Range (1 – 50000) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 25 | Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines | Magnetic flux density: in the frequency range 0 Hz Range (0,050 – 1200) mT in the frequency range from 10 Hz do 400 kHz Range 30 nT – 19 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 26 | Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines | Magnetic field strength: in the frequency range from 10 Hz do 400 kHz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 27 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Electric field strength: in the frequency range from 0,1 MHz do 18000 MHz Range (0,5 –1000) V/m in the frequency range from 18 GHz do 90 GHz Range (2 – 1000) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 28 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 100 kHz do 35 MHz Range (0,01 – 16) A/m in the frequency range from 300 kHz do 60 MHz Range (0,01 – 20) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 1) A/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 29 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Magnetic field strength: in the frequency range from 10 MHz do 90 GHz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 30 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | Power density: in the frequency range from 300 MHz do 90 GHz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 31 | Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) | Electric field strength: in the frequency range from 0,1 MHz do 18000 MHz Range (0,5 –1000) V/m in the frequency range from 18 GHz do 90 GHz Range (2 – 1000) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 32 | Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) | Magnetic field strength: in the frequency range from 100 kHz do 35 MHz Range (0,01 – 16) A/m in the frequency range from 300 kHz do 60 MHz Range (0,01 – 20) A/m in the frequency range from 30 MHz do 1 GHz Range (0,01 – 1) A/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 33 | Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) | Magnetic field strength: in the frequency range from 10 MHz do 90 GHz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 34 | Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) | Power density: in the frequency range from 300 MHz do 90 GHz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
Reference standards (9)
IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01
IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01
IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)