{"lab":{"_id":"69ad52a3de79e566650fb44a","accr_number":"AB 848","country":"PL","accr_body":"PCA","address":"INSTYTUT MORSKI, ul. Morska 81-87, 81-225 Gdynia, LABORATORIUM ELEKTRONIKI MORSKIEJ, ul. Roberta de Plelo 20","categories":["environment","automotive","electronics"],"city":"Gdynia","imported_at":"2026-03-08T10:42:43.265Z","methods_count":34,"name":"UNIWERSYTET MORSKI W GDYNI","parse_status":"parsed","parse_version":2,"pdf_files":["AB_848.pdf"],"scope_summary":"","search_text":"uniwersytet morski w gdyni instytut morski, ul. morska 81-87, 81-225 gdynia, laboratorium elektroniki morskiej, ul. roberta de plelo 20 environment pharma electronics other metrology materials automotive","status":"active","updated_at":"2026-03-08T14:51:44.087Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:19:07.885Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20848,podmiot.html","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful factors – electromagnetic field)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - electromagnetic field)"}],"issue":{"no":"26","date":"27.07.2026"},"parse_date":"2026-08-18T01:19:07.885Z","parse_source":"agent-claude-code","map_coord":[54.526437,18.511657],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM ELEKTRONIKI MORSKIEJ","address":"ul. Roberta de Plelo 20","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/3da6488dceaaa520b8ce662e703a3643/AB%20848.pdf","has_en":true,"category_counts":{"environment":34,"automotive":4,"electronics":4},"category_scores":{"environment":27.52,"automotive":0.38,"electronics":0.38},"has_zh":true},"methods":[{"_id":"6a83b30baf14b9c0e7b20be7","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery, demagnetyzatory, inne urządzenia wykorzystujące magnesy i elektromagnesy - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"(0,1 – 50000) V/m"},{"name":"w zakresie częstotliwości od 0,1 MHz","range":"do 18000 MHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"},{"name":"w zakresie częstotliwości od 18 GHz","range":"do 90 GHz"},{"name":"Zakres","range":"(2 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (0,1 – 50000) V/m\nw zakresie częstotliwości od 0,1 MHz do 18000 MHz\nZakres (0,5 – 1000) V/m\nw zakresie częstotliwości od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery, demagnetyzatory, inne urządzenia wykorzystujące magnesy i elektromagnesy - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (0,1 – 50000) V/m\nw zakresie częstotliwości od 0,1 MHz do 18000 MHz\nZakres (0,5 – 1000) V/m\nw zakresie częstotliwości od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 Srodowisko pracy − pole elektromagnetyczne pochodzace od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery, demagnetyzatory, inne urzadzenia wykorzystujace magnesy i elektromagnesy - instalacje elekrolityczne - spektrometry NMR - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazarki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres (0,1 – 50000) V/m\nw zakresie czestotliwosci od 0,1 MHz do 18000 MHz\nZakres (0,5 – 1000) V/m\nw zakresie czestotliwosci od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. zalacznik nr 2 do IB-01 zalacznik nr 5 do IB-01","categories":["environment","automotive"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"Range","range":"(0,1 – 50000) V/m"},{"name":"in the frequency range from 0,1 MHz","range":"do 18000 MHz"},{"name":"Range","range":"(0,5 – 1000) V/m"},{"name":"in the frequency range from 18 GHz","range":"do 90 GHz"},{"name":"Range","range":"(2 – 1000) V/m"}],"search_en":"Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Electric field strength: Direct measurement method in the frequency range from 10 Hz Range in the frequency range from 0,1 MHz Range in the frequency range from 18 GHz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"范围","range":"(0,1 – 50000) V/m"},{"name":"频率范围自 0,1 MHz 起","range":"do 18000 MHz"},{"name":"范围","range":"(0,5 – 1000) V/m"},{"name":"频率范围自 18 GHz 起","range":"do 90 GHz"},{"name":"范围","range":"(2 – 1000) V/m"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁机、退磁机及其他使用磁场的设备 电场强度： 直接测量法 频率范围自 10 Hz 起 范围 频率范围自 0,1 MHz 起 范围 频率范围自 18 GHz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","technique_zh":"直接测量法","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁机、退磁机及其他使用磁场的设备"},{"_id":"6a83b30baf14b9c0e7b20be8","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery, demagnetyzatory, inne urządzenia wykorzystujące magnesy i elektromagnesy - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 35 MHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"},{"name":"w zakresie częstotliwości od 300 kHz","range":"do 60 MHz"},{"name":"Zakres","range":"(0,01 – 20) A/m"},{"name":"w zakresie częstotliwości od 30 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 1) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie częstotliwości od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie częstotliwości od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery, demagnetyzatory, inne urządzenia wykorzystujące magnesy i elektromagnesy - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie częstotliwości od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie częstotliwości od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 Srodowisko pracy − pole elektromagnetyczne pochodzace od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery, demagnetyzatory, inne urzadzenia wykorzystujace magnesy i elektromagnesy - instalacje elekrolityczne - spektrometry NMR - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazarki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie czestotliwosci od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie czestotliwosci od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. zalacznik nr 2 do IB-01 zalacznik nr 5 do IB-01","categories":["environment","automotive"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 35 MHz"},{"name":"Range","range":"(0,01 – 16) A/m"},{"name":"in the frequency range from 300 kHz","range":"do 60 MHz"},{"name":"Range","range":"(0,01 – 20) A/m"},{"name":"in the frequency range from 30 MHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 1) A/m"}],"search_en":"Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Magnetic field strength: Direct measurement method in the frequency range from 100 kHz Range in the frequency range from 300 kHz Range in the frequency range from 30 MHz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 35 MHz"},{"name":"范围","range":"(0,01 – 16) A/m"},{"name":"频率范围自 300 kHz 起","range":"do 60 MHz"},{"name":"范围","range":"(0,01 – 20) A/m"},{"name":"频率范围自 30 MHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 1) A/m"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁机、退磁机及其他使用磁场的设备 磁场强度： 直接测量法 频率范围自 100 kHz 起 范围 频率范围自 300 kHz 起 范围 频率范围自 30 MHz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","technique_zh":"直接测量法","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁机、退磁机及其他使用磁场的设备"},{"_id":"6a83b30baf14b9c0e7b20be9","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery, demagnetyzatory, inne urządzenia wykorzystujące magnesy i elektromagnesy - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości 0 Hz"},{"name":"Zakres","range":"(0,050 – 1200) mT"},{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"30 nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres (0,050 – 1200) mT\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery, demagnetyzatory, inne urządzenia wykorzystujące magnesy i elektromagnesy - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres (0,050 – 1200) mT\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 Srodowisko pracy − pole elektromagnetyczne pochodzace od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery, demagnetyzatory, inne urzadzenia wykorzystujace magnesy i elektromagnesy - instalacje elekrolityczne - spektrometry NMR - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazarki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 0 Hz\nZakres (0,050 – 1200) mT\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. zalacznik nr 2 do IB-01 zalacznik nr 5 do IB-01","categories":["environment","automotive"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range 0 Hz"},{"name":"Range","range":"(0,050 – 1200) mT"},{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"Range","range":"30 nT – 19 mT"}],"search_en":"Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Magnetic flux density: Direct measurement method in the frequency range 0 Hz Range in the frequency range from 10 Hz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters","parameters_zh":[{"name":"频率范围 0 Hz"},{"name":"范围","range":"(0,050 – 1200) mT"},{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"范围","range":"30 nT – 19 mT"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁机、退磁机及其他使用磁场的设备 磁感应强度： 直接测量法 频率范围 0 Hz 范围 频率范围自 10 Hz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁机、退磁机及其他使用磁场的设备"},{"_id":"6a83b30baf14b9c0e7b20bea","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery, demagnetyzatory, inne urządzenia wykorzystujące magnesy i elektromagnesy - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"od 1 GHz","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nod 1 GHz do 3 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery, demagnetyzatory, inne urządzenia wykorzystujące magnesy i elektromagnesy - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nod 1 GHz do 3 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 Srodowisko pracy − pole elektromagnetyczne pochodzace od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery, demagnetyzatory, inne urzadzenia wykorzystujace magnesy i elektromagnesy - instalacje elekrolityczne - spektrometry NMR - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazarki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nod 1 GHz do 3 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. zalacznik nr 2 do IB-01 zalacznik nr 5 do IB-01","categories":["environment","automotive"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"from 1 GHz","range":"do 3 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters Magnetic field strength: in the frequency range from 10 Hz from 1 GHz (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","test_object_en":"Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers, demagnetisers, other equipment using magnets and electromagnets - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"od 1 GHz","range":"do 3 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁机、退磁机及其他使用磁场的设备 磁场强度： 频率范围自 10 Hz 起 （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁机、退磁机及其他使用磁场的设备"},{"_id":"6a83b30baf14b9c0e7b20beb","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego / niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"(0,1 – 50000) V/m"},{"name":"w zakresie częstotliwości od 0,1 MHz","range":"do 18000 MHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"},{"name":"w zakresie częstotliwości od 18 GHz","range":"do 90 GHz"},{"name":"Zakres","range":"(2 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (0,1 – 50000) V/m\nw zakresie częstotliwości od 0,1 MHz do 18000 MHz\nZakres (0,5 – 1000) V/m\nw zakresie częstotliwości od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego / niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (0,1 – 50000) V/m\nw zakresie częstotliwości od 0,1 MHz do 18000 MHz\nZakres (0,5 – 1000) V/m\nw zakresie częstotliwości od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01 Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy radarowe: pola stacjonarnego / niestacjonarnego - systemy antykradziezowe oraz elektronicznej kontroli obiektow Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres (0,1 – 50000) V/m\nw zakresie czestotliwosci od 0,1 MHz do 18000 MHz\nZakres (0,5 – 1000) V/m\nw zakresie czestotliwosci od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. zalacznik nr 2 do IB-01 zalacznik nr 3 do IB-01 zalacznik nr 4 do IB-01","categories":["environment","electronics"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"Range","range":"(0,1 – 50000) V/m"},{"name":"in the frequency range from 0,1 MHz","range":"do 18000 MHz"},{"name":"Range","range":"(0,5 – 1000) V/m"},{"name":"in the frequency range from 18 GHz","range":"do 90 GHz"},{"name":"Range","range":"(2 – 1000) V/m"}],"search_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems Electric field strength: Direct measurement method in the frequency range from 10 Hz Range in the frequency range from 0,1 MHz Range in the frequency range from 18 GHz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"范围","range":"(0,1 – 50000) V/m"},{"name":"频率范围自 0,1 MHz 起","range":"do 18000 MHz"},{"name":"范围","range":"(0,5 – 1000) V/m"},{"name":"频率范围自 18 GHz 起","range":"do 90 GHz"},{"name":"范围","range":"(2 – 1000) V/m"}],"search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身电台（对讲机） 电场强度： 直接测量法 频率范围自 10 Hz 起 范围 频率范围自 0,1 MHz 起 范围 频率范围自 18 GHz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身电台（对讲机）"},{"_id":"6a83b30baf14b9c0e7b20bec","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego / niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 35 MHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"},{"name":"w zakresie częstotliwości od 300 kHz","range":"do 60 MHz"},{"name":"Zakres","range":"(0,01 – 20) A/m"},{"name":"w zakresie częstotliwości od 30 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 1) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie częstotliwości od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie częstotliwości od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego / niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie częstotliwości od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie częstotliwości od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01 Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy radarowe: pola stacjonarnego / niestacjonarnego - systemy antykradziezowe oraz elektronicznej kontroli obiektow Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie czestotliwosci od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie czestotliwosci od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. zalacznik nr 2 do IB-01 zalacznik nr 3 do IB-01 zalacznik nr 4 do IB-01","categories":["environment","electronics"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 35 MHz"},{"name":"Range","range":"(0,01 – 16) A/m"},{"name":"in the frequency range from 300 kHz","range":"do 60 MHz"},{"name":"Range","range":"(0,01 – 20) A/m"},{"name":"in the frequency range from 30 MHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 1) A/m"}],"search_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems Magnetic field strength: Direct measurement method in the frequency range from 100 kHz Range in the frequency range from 300 kHz Range in the frequency range from 30 MHz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 35 MHz"},{"name":"范围","range":"(0,01 – 16) A/m"},{"name":"频率范围自 300 kHz 起","range":"do 60 MHz"},{"name":"范围","range":"(0,01 – 20) A/m"},{"name":"频率范围自 30 MHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 1) A/m"}],"search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身电台（对讲机） 磁场强度： 直接测量法 频率范围自 100 kHz 起 范围 频率范围自 300 kHz 起 范围 频率范围自 30 MHz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身电台（对讲机）"},{"_id":"6a83b30baf14b9c0e7b20bed","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego / niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości 0 Hz"},{"name":"Zakres","range":"(0,050 – 1200) mT"},{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"30 nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres (0,050 – 1200) mT\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego / niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres (0,050 – 1200) mT\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01 Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy radarowe: pola stacjonarnego / niestacjonarnego - systemy antykradziezowe oraz elektronicznej kontroli obiektow Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 0 Hz\nZakres (0,050 – 1200) mT\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. zalacznik nr 2 do IB-01 zalacznik nr 3 do IB-01 zalacznik nr 4 do IB-01","categories":["environment","electronics"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range 0 Hz"},{"name":"Range","range":"(0,050 – 1200) mT"},{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"Range","range":"30 nT – 19 mT"}],"search_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems Magnetic flux density: Direct measurement method in the frequency range 0 Hz Range in the frequency range from 10 Hz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems","parameters_zh":[{"name":"频率范围 0 Hz"},{"name":"范围","range":"(0,050 – 1200) mT"},{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"范围","range":"30 nT – 19 mT"}],"search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身电台（对讲机） 磁感应强度： 直接测量法 频率范围 0 Hz 范围 频率范围自 10 Hz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身电台（对讲机）"},{"_id":"6a83b30baf14b9c0e7b20bee","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego / niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"od 1 GHz","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nod 1 GHz do 3 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy radarowe: pola stacjonarnego / niestacjonarnego - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nod 1 GHz do 3 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01 Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy radarowe: pola stacjonarnego / niestacjonarnego - systemy antykradziezowe oraz elektronicznej kontroli obiektow Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nod 1 GHz do 3 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. zalacznik nr 2 do IB-01 zalacznik nr 3 do IB-01 zalacznik nr 4 do IB-01","categories":["environment","electronics"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"from 1 GHz","range":"do 3 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems Magnetic field strength: in the frequency range from 10 Hz from 1 GHz (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01","test_object_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - anti-theft and electronic article surveillance systems","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"od 1 GHz","range":"do 3 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身电台（对讲机） 磁场强度： 频率范围自 10 Hz 起 （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 2 do IB-01 załącznik nr 3 do IB-01 załącznik nr 4 do IB-01","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身电台（对讲机）"},{"_id":"6a83b30baf14b9c0e7b20bef","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"(0,1 – 50000) V/m"},{"name":"w zakresie częstotliwości od 0,1 MHz","range":"do 18000 MHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"},{"name":"w zakresie częstotliwości od 18 GHz","range":"do 90 GHz"},{"name":"Zakres","range":"(2 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (0,1 – 50000) V/m\nw zakresie częstotliwości od 0,1 MHz do 18000 MHz\nZakres (0,5 – 1000) V/m\nw zakresie częstotliwości od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (0,1 – 50000) V/m\nw zakresie częstotliwości od 0,1 MHz do 18000 MHz\nZakres (0,5 – 1000) V/m\nw zakresie częstotliwości od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres (0,1 – 50000) V/m\nw zakresie czestotliwosci od 0,1 MHz do 18000 MHz\nZakres (0,5 – 1000) V/m\nw zakresie czestotliwosci od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. zalacznik nr 1 do IB-01 zalacznik nr 2 do IB-01 zalacznik nr 5 do IB-01","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"Range","range":"(0,1 – 50000) V/m"},{"name":"in the frequency range from 0,1 MHz","range":"do 18000 MHz"},{"name":"Range","range":"(0,5 – 1000) V/m"},{"name":"in the frequency range from 18 GHz","range":"do 90 GHz"},{"name":"Range","range":"(2 – 1000) V/m"}],"search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Electric field strength: Direct measurement method in the frequency range from 10 Hz Range in the frequency range from 0,1 MHz Range in the frequency range from 18 GHz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"范围","range":"(0,1 – 50000) V/m"},{"name":"频率范围自 0,1 MHz 起","range":"do 18000 MHz"},{"name":"范围","range":"(0,5 – 1000) V/m"},{"name":"频率范围自 18 GHz 起","range":"do 90 GHz"},{"name":"范围","range":"(2 – 1000) V/m"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 电场强度： 直接测量法 频率范围自 10 Hz 起 范围 频率范围自 0,1 MHz 起 范围 频率范围自 18 GHz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a83b30baf14b9c0e7b20bf0","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 35 MHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"},{"name":"w zakresie częstotliwości od 300 kHz","range":"do 60 MHz"},{"name":"Zakres","range":"(0,01 – 20) A/m"},{"name":"w zakresie częstotliwości od 30 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 1) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie częstotliwości od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie częstotliwości od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie częstotliwości od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie częstotliwości od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie czestotliwosci od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie czestotliwosci od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. zalacznik nr 1 do IB-01 zalacznik nr 2 do IB-01 zalacznik nr 5 do IB-01","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 35 MHz"},{"name":"Range","range":"(0,01 – 16) A/m"},{"name":"in the frequency range from 300 kHz","range":"do 60 MHz"},{"name":"Range","range":"(0,01 – 20) A/m"},{"name":"in the frequency range from 30 MHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 1) A/m"}],"search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic field strength: Direct measurement method in the frequency range from 100 kHz Range in the frequency range from 300 kHz Range in the frequency range from 30 MHz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 35 MHz"},{"name":"范围","range":"(0,01 – 16) A/m"},{"name":"频率范围自 300 kHz 起","range":"do 60 MHz"},{"name":"范围","range":"(0,01 – 20) A/m"},{"name":"频率范围自 30 MHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 1) A/m"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 磁场强度： 直接测量法 频率范围自 100 kHz 起 范围 频率范围自 300 kHz 起 范围 频率范围自 30 MHz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a83b30baf14b9c0e7b20bf1","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości 0 Hz"},{"name":"Zakres","range":"(0,050 – 1200) mT"},{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"30 nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres (0,050 – 1200) mT\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres (0,050 – 1200) mT\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 0 Hz\nZakres (0,050 – 1200) mT\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. zalacznik nr 1 do IB-01 zalacznik nr 2 do IB-01 zalacznik nr 5 do IB-01","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range 0 Hz"},{"name":"Range","range":"(0,050 – 1200) mT"},{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"Range","range":"30 nT – 19 mT"}],"search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic flux density: Direct measurement method in the frequency range 0 Hz Range in the frequency range from 10 Hz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners","parameters_zh":[{"name":"频率范围 0 Hz"},{"name":"范围","range":"(0,050 – 1200) mT"},{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"范围","range":"30 nT – 19 mT"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 磁感应强度： 直接测量法 频率范围 0 Hz 范围 频率范围自 10 Hz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a83b30baf14b9c0e7b20bf2","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"od 1 GHz","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nod 1 GHz do 3 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nod 1 GHz do 3 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01 Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nod 1 GHz do 3 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. zalacznik nr 1 do IB-01 zalacznik nr 2 do IB-01 zalacznik nr 5 do IB-01","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"from 1 GHz","range":"do 3 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic field strength: in the frequency range from 10 Hz from 1 GHz (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"od 1 GHz","range":"do 3 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 磁场强度： 频率范围自 10 Hz 起 （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | IB-01 edycja 9 z dnia 25.06.2025 r. załącznik nr 1 do IB-01 załącznik nr 2 do IB-01 załącznik nr 5 do IB-01","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a83b30baf14b9c0e7b20bf3","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 45 Hz","range":"do 55 Hz"},{"name":"Zakres","range":"(1 – 50000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 45 Hz do 55 Hz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 45 Hz do 55 Hz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 45 Hz do 55 Hz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 – 150","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 45 Hz","range":"do 55 Hz"},{"name":"Range","range":"(1 – 50000) V/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Electric field strength: Direct measurement method in the frequency range from 45 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 45 Hz 起","range":"do 55 Hz"},{"name":"范围","range":"(1 – 50000) V/m"}],"search_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场 电场强度： 直接测量法 频率范围自 45 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场"},{"_id":"6a83b30baf14b9c0e7b20bf4","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 45 Hz","range":"do 55 Hz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 45 Hz do 55 Hz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 45 Hz do 55 Hz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 45 Hz do 55 Hz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 – 150","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 45 Hz","range":"do 55 Hz"},{"name":"(calculated)"}],"search_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic field strength: in the frequency range from 45 Hz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 45 Hz 起","range":"do 55 Hz"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场 磁场强度： 频率范围自 45 Hz 起 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","test_object_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场"},{"_id":"6a83b30baf14b9c0e7b20bf5","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości od 45 Hz","range":"do 55 Hz"},{"name":"Zakres","range":"30 nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 45 Hz do 55 Hz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 45 Hz do 55 Hz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci od 45 Hz do 55 Hz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 – 150","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range from 45 Hz","range":"do 55 Hz"},{"name":"Range","range":"30 nT – 19 mT"}],"search_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic flux density: Direct measurement method in the frequency range from 45 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry","parameters_zh":[{"name":"频率范围自 45 Hz 起","range":"do 55 Hz"},{"name":"范围","range":"30 nT – 19 mT"}],"search_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场 磁感应强度： 直接测量法 频率范围自 45 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场"},{"_id":"6a83b30baf14b9c0e7b20bf6","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii (metoda uproszczona)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 20 Hz","range":"do 55 Hz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 55 Hz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii (metoda uproszczona) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 55 Hz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen do magnetoterapii (metoda uproszczona) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 20 Hz do 55 Hz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 – 180","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 20 Hz","range":"do 55 Hz"},{"name":"(calculated)"}],"search_en":"Workplace environment - electromagnetic field in the work space during the use of magnetotherapy devices (simplified method) Magnetic field strength: in the frequency range from 20 Hz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","test_object_en":"Workplace environment - electromagnetic field in the work space during the use of magnetotherapy devices (simplified method)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 20 Hz 起","range":"do 55 Hz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： 频率范围自 20 Hz 起 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180"},{"_id":"6a83b30baf14b9c0e7b20bf7","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii (metoda uproszczona)","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości od 20 Hz","range":"do 55 Hz"},{"name":"Zakres","range":"30 nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 20 Hz do 55 Hz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii (metoda uproszczona) Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 20 Hz do 55 Hz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen do magnetoterapii (metoda uproszczona) Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci od 20 Hz do 55 Hz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 – 180","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range from 20 Hz","range":"do 55 Hz"},{"name":"Range","range":"30 nT – 19 mT"}],"search_en":"Workplace environment - electromagnetic field in the work space during the use of magnetotherapy devices (simplified method) Magnetic flux density: Direct measurement method in the frequency range from 20 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the work space during the use of magnetotherapy devices (simplified method)","parameters_zh":[{"name":"频率范围自 20 Hz 起","range":"do 55 Hz"},{"name":"范围","range":"30 nT – 19 mT"}],"search_zh":"磁感应强度： 直接测量法 频率范围自 20 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","technique_zh":"直接测量法","methodology_zh":"磁感应强度："},{"_id":"6a83b30baf14b9c0e7b20bf8","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 0,1 MHz","range":"do 18000 MHz"},{"name":"Zakres","range":"(0,5 – 1000) V/m"},{"name":"w zakresie częstotliwości od 18 GHz","range":"do 90 GHz"},{"name":"Zakres","range":"(2 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18000 MHz\nZakres (0,5 – 1000) V/m\nw zakresie częstotliwości od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18000 MHz\nZakres (0,5 – 1000) V/m\nw zakresie częstotliwości od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 18000 MHz\nZakres (0,5 – 1000) V/m\nw zakresie czestotliwosci od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 0,1 MHz","range":"do 18000 MHz"},{"name":"Range","range":"(0,5 – 1000) V/m"},{"name":"in the frequency range from 18 GHz","range":"do 90 GHz"},{"name":"Range","range":"(2 – 1000) V/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Electric field strength: Direct measurement method in the frequency range from 0,1 MHz Range in the frequency range from 18 GHz Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 0,1 MHz 起","range":"do 18000 MHz"},{"name":"范围","range":"(0,5 – 1000) V/m"},{"name":"频率范围自 18 GHz 起","range":"do 90 GHz"},{"name":"范围","range":"(2 – 1000) V/m"}],"search_zh":"电场强度： 直接测量法 频率范围自 0,1 MHz 起 范围 频率范围自 18 GHz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法"},{"_id":"6a83b30baf14b9c0e7b20bf9","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 35 MHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"},{"name":"w zakresie częstotliwości od 300 kHz","range":"do 60 MHz"},{"name":"Zakres","range":"(0,01 – 20) A/m"},{"name":"w zakresie częstotliwości od 30 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 1) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie częstotliwości od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie częstotliwości od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie częstotliwości od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie częstotliwości od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie czestotliwosci od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie czestotliwosci od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 35 MHz"},{"name":"Range","range":"(0,01 – 16) A/m"},{"name":"in the frequency range from 300 kHz","range":"do 60 MHz"},{"name":"Range","range":"(0,01 – 20) A/m"},{"name":"in the frequency range from 30 MHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 1) A/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength: Direct measurement method in the frequency range from 100 kHz Range in the frequency range from 300 kHz Range in the frequency range from 30 MHz Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 35 MHz"},{"name":"范围","range":"(0,01 – 16) A/m"},{"name":"频率范围自 300 kHz 起","range":"do 60 MHz"},{"name":"范围","range":"(0,01 – 20) A/m"},{"name":"频率范围自 30 MHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 1) A/m"}],"search_zh":"磁场强度： 直接测量法 频率范围自 100 kHz 起 范围 频率范围自 300 kHz 起 范围 频率范围自 30 MHz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法"},{"_id":"6a83b30baf14b9c0e7b20bfa","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 0,8 GHz","range":"do 90 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 90 GHz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,8 GHz do 90 GHz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,8 GHz do 90 GHz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 0,8 GHz","range":"do 90 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength: in the frequency range from 0,8 GHz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0,8 GHz 起","range":"do 90 GHz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： 频率范围自 0,8 GHz 起 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"},{"_id":"6a83b30baf14b9c0e7b20bfb","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"(1 – 50000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"(1 – 50000) V/m"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: Direct measurement method in the frequency range 50 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"(1 – 50000) V/m"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 电场强度： 直接测量法 频率范围 50 Hz 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a83b30baf14b9c0e7b20bfc","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"30 nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"30 nT – 19 mT"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density: Direct measurement method in the frequency range 50 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"30 nT – 19 mT"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 磁感应强度： 直接测量法 频率范围 50 Hz 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","methodology_zh":"磁感应强度："},{"_id":"6a83b30baf14b9c0e7b20bfd","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości 50 Hz (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości 50 Hz (z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego:\nw zakresie częstotliwości 50 Hz (z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego:\nw zakresie czestotliwosci 50 Hz (z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range 50 Hz (calculated)"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength: in the frequency range 50 Hz (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology_zh":"磁场强度：","search_zh":"环境 — 变电站与输电线路周围的电磁场 磁场强度： 频率 50 Hz 范围内（由计算得出） Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","parameters_zh":[{"name":"频率 50 Hz 范围内（由计算得出）"}]},{"_id":"6a83b30baf14b9c0e7b20bfe","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu przemysłowych stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"(1 – 50000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu przemysłowych stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu przemyslowych stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"Range","range":"(1 – 50000) V/m"}],"search_en":"Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines Electric field strength: Direct measurement method in the frequency range from 10 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"范围","range":"(1 – 50000) V/m"}],"search_zh":"电场强度： 直接测量法 频率范围自 10 Hz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法"},{"_id":"6a83b30baf14b9c0e7b20bff","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu przemysłowych stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości 0 Hz"},{"name":"Zakres","range":"(0,050 – 1200) mT"},{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"30 nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres (0,050 – 1200) mT\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu przemysłowych stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres (0,050 – 1200) mT\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu przemyslowych stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 0 Hz\nZakres (0,050 – 1200) mT\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres 30 nT – 19 mT\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range 0 Hz"},{"name":"Range","range":"(0,050 – 1200) mT"},{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"Range","range":"30 nT – 19 mT"}],"search_en":"Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines Magnetic flux density: Direct measurement method in the frequency range 0 Hz Range in the frequency range from 10 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines","parameters_zh":[{"name":"频率范围 0 Hz"},{"name":"范围","range":"(0,050 – 1200) mT"},{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"范围","range":"30 nT – 19 mT"}],"search_zh":"磁感应强度： 直接测量法 频率范围 0 Hz 范围 频率范围自 10 Hz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","methodology_zh":"磁感应强度："},{"_id":"6a83b30baf14b9c0e7b20c00","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu przemysłowych stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\n(z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu przemysłowych stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\n(z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu przemyslowych stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\n(z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"(calculated)"}],"search_en":"Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines Magnetic field strength: in the frequency range from 10 Hz (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of industrial electric power substations and power lines","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： 频率范围自 10 Hz 起 （计算得出） Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"},{"_id":"6a83b30baf14b9c0e7b20c01","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 0,1 MHz","range":"do 18000 MHz"},{"name":"Zakres","range":"(0,5 –1000) V/m"},{"name":"w zakresie częstotliwości od 18 GHz","range":"do 90 GHz"},{"name":"Zakres","range":"(2 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18000 MHz\nZakres (0,5 –1000) V/m\nw zakresie częstotliwości od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18000 MHz\nZakres (0,5 –1000) V/m\nw zakresie częstotliwości od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 18000 MHz\nZakres (0,5 –1000) V/m\nw zakresie czestotliwosci od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 0,1 MHz","range":"do 18000 MHz"},{"name":"Range","range":"(0,5 –1000) V/m"},{"name":"in the frequency range from 18 GHz","range":"do 90 GHz"},{"name":"Range","range":"(2 – 1000) V/m"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range from 0,1 MHz Range in the frequency range from 18 GHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 0,1 MHz 起","range":"do 18000 MHz"},{"name":"范围","range":"(0,5 –1000) V/m"},{"name":"频率范围自 18 GHz 起","range":"do 90 GHz"},{"name":"范围","range":"(2 – 1000) V/m"}],"search_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量） 电场强度： 直接测量法 频率范围自 0,1 MHz 起 范围 频率范围自 18 GHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量）"},{"_id":"6a83b30baf14b9c0e7b20c02","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 35 MHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"},{"name":"w zakresie częstotliwości od 300 kHz","range":"do 60 MHz"},{"name":"Zakres","range":"(0,01 – 20) A/m"},{"name":"w zakresie częstotliwości od 30 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 1) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie częstotliwości od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie częstotliwości od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie częstotliwości od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie częstotliwości od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie czestotliwosci od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie czestotliwosci od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 35 MHz"},{"name":"Range","range":"(0,01 – 16) A/m"},{"name":"in the frequency range from 300 kHz","range":"do 60 MHz"},{"name":"Range","range":"(0,01 – 20) A/m"},{"name":"in the frequency range from 30 MHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 1) A/m"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Magnetic field strength: Direct measurement method in the frequency range from 100 kHz Range in the frequency range from 300 kHz Range in the frequency range from 30 MHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 35 MHz"},{"name":"范围","range":"(0,01 – 16) A/m"},{"name":"频率范围自 300 kHz 起","range":"do 60 MHz"},{"name":"范围","range":"(0,01 – 20) A/m"},{"name":"频率范围自 30 MHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 1) A/m"}],"search_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量） 磁场强度： 直接测量法 频率范围自 100 kHz 起 范围 频率范围自 300 kHz 起 范围 频率范围自 30 MHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量）"},{"_id":"6a83b30baf14b9c0e7b20c03","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 MHz","range":"do 90 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 90 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 90 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 MHz do 90 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 10 MHz","range":"do 90 GHz"},{"name":"(calculated)"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Magnetic field strength: in the frequency range from 10 MHz (calculated) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 MHz 起","range":"do 90 GHz"},{"name":"（计算得出）"}],"search_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量） 磁场强度： 频率范围自 10 MHz 起 （计算得出） Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量）"},{"_id":"6a83b30baf14b9c0e7b20c04","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe)","methodology":"Gęstość mocy:","parameters":[{"name":"w zakresie częstotliwości od 300 MHz","range":"do 90 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość mocy:\nZakres:\nw zakresie częstotliwości od 300 MHz do 90 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Gęstość mocy:\nZakres:\nw zakresie częstotliwości od 300 MHz do 90 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych i radionawigacyjnych (pomiary szerokopasmowe) Gestosc mocy:\nZakres:\nw zakresie czestotliwosci od 300 MHz do 90 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Power density:","parameters_en":[{"name":"in the frequency range from 300 MHz","range":"do 90 GHz"},{"name":"(calculated)"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) Power density: in the frequency range from 300 MHz (calculated) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements)","parameters_zh":[{"name":"w zakresie częstotliwości od 300 MHz","range":"do 90 GHz"},{"name":"（计算得出）"}],"search_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量） （计算得出） Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 － 无线电通信与无线电导航设施周围的电磁场（宽带测量）"},{"_id":"6a83b30baf14b9c0e7b20c05","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 0,1 MHz","range":"do 18000 MHz"},{"name":"Zakres","range":"(0,5 –1000) V/m"},{"name":"w zakresie częstotliwości od 18 GHz","range":"do 90 GHz"},{"name":"Zakres","range":"(2 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18000 MHz\nZakres (0,5 –1000) V/m\nw zakresie częstotliwości od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 18000 MHz\nZakres (0,5 –1000) V/m\nw zakresie częstotliwości od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 18000 MHz\nZakres (0,5 –1000) V/m\nw zakresie czestotliwosci od 18 GHz do 90 GHz\nZakres (2 – 1000) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 0,1 MHz","range":"do 18000 MHz"},{"name":"Range","range":"(0,5 –1000) V/m"},{"name":"in the frequency range from 18 GHz","range":"do 90 GHz"},{"name":"Range","range":"(2 – 1000) V/m"}],"search_en":"Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range from 0,1 MHz Range in the frequency range from 18 GHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of radar installations (broadband measurements)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 0,1 MHz 起","range":"do 18000 MHz"},{"name":"范围","range":"(0,5 –1000) V/m"},{"name":"频率范围自 18 GHz 起","range":"do 90 GHz"},{"name":"范围","range":"(2 – 1000) V/m"}],"search_zh":"环境 － 雷达设施周围的电磁场（宽带测量） 电场强度： 直接测量法 频率范围自 0,1 MHz 起 范围 频率范围自 18 GHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 雷达设施周围的电磁场（宽带测量）"},{"_id":"6a83b30baf14b9c0e7b20c06","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz","range":"do 35 MHz"},{"name":"Zakres","range":"(0,01 – 16) A/m"},{"name":"w zakresie częstotliwości od 300 kHz","range":"do 60 MHz"},{"name":"Zakres","range":"(0,01 – 20) A/m"},{"name":"w zakresie częstotliwości od 30 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 1) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie częstotliwości od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie częstotliwości od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie częstotliwości od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie częstotliwości od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 35 MHz\nZakres (0,01 – 16) A/m\nw zakresie czestotliwosci od 300 kHz do 60 MHz\nZakres (0,01 – 20) A/m\nw zakresie czestotliwosci od 30 MHz do 1 GHz\nZakres (0,01 – 1) A/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 100 kHz","range":"do 35 MHz"},{"name":"Range","range":"(0,01 – 16) A/m"},{"name":"in the frequency range from 300 kHz","range":"do 60 MHz"},{"name":"Range","range":"(0,01 – 20) A/m"},{"name":"in the frequency range from 30 MHz","range":"do 1 GHz"},{"name":"Range","range":"(0,01 – 1) A/m"}],"search_en":"Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) Magnetic field strength: Direct measurement method in the frequency range from 100 kHz Range in the frequency range from 300 kHz Range in the frequency range from 30 MHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of radar installations (broadband measurements)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 100 kHz 起","range":"do 35 MHz"},{"name":"范围","range":"(0,01 – 16) A/m"},{"name":"频率范围自 300 kHz 起","range":"do 60 MHz"},{"name":"范围","range":"(0,01 – 20) A/m"},{"name":"频率范围自 30 MHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 1) A/m"}],"search_zh":"环境 － 雷达设施周围的电磁场（宽带测量） 磁场强度： 直接测量法 频率范围自 100 kHz 起 范围 频率范围自 300 kHz 起 范围 频率范围自 30 MHz 起 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 雷达设施周围的电磁场（宽带测量）"},{"_id":"6a83b30baf14b9c0e7b20c07","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 MHz","range":"do 90 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 90 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 90 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 MHz do 90 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 10 MHz","range":"do 90 GHz"},{"name":"(calculated)"}],"search_en":"Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) Magnetic field strength: in the frequency range from 10 MHz (calculated) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of radar installations (broadband measurements)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 MHz 起","range":"do 90 GHz"},{"name":"（计算得出）"}],"search_zh":"环境 － 雷达设施周围的电磁场（宽带测量） 磁场强度： 频率范围自 10 MHz 起 （计算得出） Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 － 雷达设施周围的电磁场（宽带测量）"},{"_id":"6a83b30baf14b9c0e7b20c08","lab_id":"69ad52a3de79e566650fb44a","country":"PL","accr_number":"AB 848","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych (pomiary szerokopasmowe)","methodology":"Gęstość mocy:","parameters":[{"name":"w zakresie częstotliwości od 300 MHz","range":"do 90 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość mocy:\nZakres:\nw zakresie częstotliwości od 300 MHz do 90 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Elektroniki Morskiej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych (pomiary szerokopasmowe) Gęstość mocy:\nZakres:\nw zakresie częstotliwości od 300 MHz do 90 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiolokacyjnych (pomiary szerokopasmowe) Gestosc mocy:\nZakres:\nw zakresie czestotliwosci od 300 MHz do 90 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Power density:","parameters_en":[{"name":"in the frequency range from 300 MHz","range":"do 90 GHz"},{"name":"(calculated)"}],"search_en":"Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) Power density: in the frequency range from 300 MHz (calculated) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of radar installations (broadband measurements)","parameters_zh":[{"name":"w zakresie częstotliwości od 300 MHz","range":"do 90 GHz"},{"name":"（计算得出）"}],"search_zh":"环境 － 雷达设施周围的电磁场（宽带测量） （计算得出） Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 － 雷达设施周围的电磁场（宽带测量）"}],"has_pdf":true}