🇵🇱 SOSNOWIECKIE WODOCIĄGI S.A. PL

PCA AB 844 • Sosnowiec, Poland • 27 methods

Water & wastewaterMaterials & polymers

SOSNOWIECKIE WODOCIĄGI S.A. is a laboratory accredited by PCA under number AB 844 (Sosnowiec, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater, Materials & polymers. Test objects include: Water, Wastewater, Sewage sludge, Wastewater, Water intended for human consumption. Most frequently used techniques: Gravimetric method, Spectrophotometric method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 844
  • Methods in scope: 27
  • Types of test objects: 4
  • Techniques used: 9
  • City: Sosnowiec, Poland
Accreditation number
AB 844
Accreditation body
PCA
Address
LABORATORIUM, ul. Ostrogórska 43, 41-200 Sosnowiec
City
Sosnowiec, Poland

What this laboratory tests (4)

Analytical techniques used (9)

Accreditation scope — test methods (27)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, Wastewater Nitrate nitrogen concentration
Range (0,070 – 60) mg/l
Spectrophotometric method PN-82/C-04576/08
2 Water, Wastewater Nitrite nitrogen concentration
Range (0,005 – 1,52) mg/l
Spectrophotometric method PN-EN 26777:1999
3 Water, Wastewater Orthophosphate concentration
Range (0,12 – 92) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010
4 Water, Wastewater Total phosphorus concentration
Range (0,040 - 30) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010
5 Water, Wastewater Kjeldahl nitrogen concentration
Range (0,50 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
6 Water, Wastewater Chemical oxygen demand
COD Range (17 – 20000) mg/l O2
Titrimetric method PN-ISO 6060:2006
7 Water, Wastewater Chloride concentration
Range (2,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
8 Water, Wastewater Biochemical oxygen demand
BOD5 Range (2 – 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12.
9 Water, Wastewater Total suspended solids (TSS)
Range (4,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
10 Water, Wastewater Ammonium nitrogen concentration
Range (0,66 – 1000) mg/l
Titrimetric method PN-ISO 5664:2002
11 Water, Wastewater Total nitrogen concentration (calculated) PB-02 wydanie 3 z dnia 28.02.2017 r.
12 Water, Wastewater Sulfate concentration
Range (8,0 – 1650) mg/l
Turbidimetric method PB-03 wydanie 3 z dnia 28.02.2017 r. | na podstawie testu kuwetowego HACH nr 8051
13 Water, Wastewater Sulfate concentration
Range (10 – 5000) mg/l
Gravimetric method PN-ISO 9280:2002
14 Water, Wastewater Iron concentration
Range (0,040 – 100) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
15 Water, Wastewater Metal content
copper (0,02 – 10) mg/L zinc (0,02 – 100) mg/L lead (0,11 – 5) mg/L cadmium (0,02 – 1) mg/L nickel (0,06 – 10) mg/L
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002
16 Water, Wastewater Mineral oil index
Range (0,25 – 50) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
17 Water, Wastewater Phenol index (phenols)
Range (0,002 – 1,0) mg/l
Spectrophotometric method PN-ISO 6439:1994 pkt. 5
18 Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (5,0 – 1000) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
19 Water intended for human consumption Iron concentration
Range (0,040 – 100) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
20 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (5,0 – 30,0) °C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PB-08 wydanie 1 z dnia 03.10.2024 r.
21 Wastewater Concentration of substances extractable with petroleum ether
Range (10 – 2000) mg/l
Gravimetric method PB-04 wydanie C z dnia 27.10.2017 r.
22 Wastewater pH
Range (4,0 – 10,0)
Potentiometric method PN-EN ISO 10523:2012
23 Sewage sludge Dry residue (dry matter)
Range (0,17 – 98,3) % Range (1,7 – 998,3) g/kg
Gravimetric method PN-EN 12880:2004
24 Sewage sludge Water content
Range (0,17 – 98,3) % Range (1,7 – 998,3) g/kg
Gravimetric method PN-EN 12880:2004
25 Sewage sludge Residue on ignition of the dry matter of sludge (mineral substances)
Range (0,14 – 98,6) %
Gravimetric method PN-EN 12879:2004
26 Sewage sludge Loss on ignition of sludge dry matter (organic matter)
Range (0,14 – 98,6) %
Gravimetric method PN-EN 12879:2004
27 Sewage sludge Metal content
copper (4,0 – 1000) mg/kg zinc (4,0 – 10000) mg/kg lead (10 – 1000) mg/kg cadmium (3,0 – 200) mg/kg nickel (6,0 – 1000) mg/kg
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 Ib-12 wydanie 1 z dnia 11.03.2019 r.

Reference standards (26)

PB-02 wydanie 3 z dnia 28.02.2017 r.
PB-03 wydanie 3 z dnia 28.02.2017 r.
PB-04 wydanie C z dnia 27.10.2017 r.
PB-08 wydanie 1 z dnia 03.10.2024 r.
PN-82/C-04576/08
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019-12.
PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010
PN-EN ISO 9377-2:2003
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 6439:1994 pkt. 5
PN-ISO 8288:2002
PN-ISO 8288:2002 Ib-12 wydanie 1 z dnia 11.03.2019 r.
PN-ISO 9280:2002
PN-ISO 9297:1994
na podstawie testu kuwetowego HACH nr 8051