🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI PL

PCA AB 836 • Jarosław, Poland • 33 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 836 (Jarosław, Poland). Its accreditation scope covers 33 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Wastewater, Water, Water, Water, Wastewater. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 836
  • Methods in scope: 33
  • Types of test objects: 6
  • Techniques used: 11
  • City: Jarosław, Poland
Accreditation number
AB 836
Accreditation body
PCA
Address
W JAROSŁAWIU Sp. z o. o., LABORATORIUM, ul. Hetmana J. Tarnowskiego 28, 37-500 Jarosław
City
Jarosław, Poland

What this laboratory tests (6)

Analytical techniques used (11)

Laboratory sections (3)

Laboratory locations

Accreditation scope — test methods (33)

No. Test object Methodology / Parameters Technique Reference document
Chemical Laboratory for Wastewater Testing
1 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (1,0 – 35) 0C
Manual and automatic method PN-ISO 5667-10:2021-11 z wył. p. 5.4 | PN-77/C-04584
2 Water Sampling for chemical and physical testing Temperature of the water sample taken
Range (1,0 – 35) 0C
PN-EN ISO 5667-6:2016-12 | PN-77/C-04584
3 Wastewater, Water Ammonium nitrogen concentration
Range (0,050 – 100) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
4 Wastewater, Water Nitrite nitrogen concentration
Range (0,0125 – 2,5) mg/l
Spectrophotometric method PN-EN 26777:1999
5 Wastewater, Water Nitrate nitrogen concentration
Range (0,10 – 25) mg/l
Spectrophotometric method PN-82/C-04576/08
6 Wastewater, Water Total nitrogen concentration, Calculated PN-73/C-04576.14
7 Wastewater, Water Kjeldahl nitrogen concentration
Range (1,25 – 150) mg/l
Titrimetric method PN-EN 25663:2001
8 Wastewater, Water Total phosphorus concentration
Range (0,040 – 40) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 rozdz. 8 + Ap.1:2010: + Ap.2:2010
9 Wastewater, Water Chemical oxygen demand SP-COD
Range (10 – 4000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
10 Wastewater, Water Biochemical oxygen demand
BOD5 Range (1 – 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12 IR-PCHŚ-120/PO-6 wyd. nr 1 z dnia 16.03.2020
11 Water, Wastewater Total suspended solids (TSS)
Range (5,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007 + Ap. 1:2007
12 Water, Wastewater Concentration of organic substances extractable with petroleum ether
Range (5,0 – 300) mg/l
Gravimetric method PN-86/C-04573.01
13 Water, Wastewater Chloride concentration
Range (5,0 – 1600) mg/l
Titrimetric method PN-ISO 9297:1994
14 Water, Wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
15 Water, Wastewater Sulfate concentration
Range (10 – 500) mg/l
Gravimetric method PN-ISO 9280:2002
Chemical Laboratory for Water Testing
16 Water, Water intended for human consumption Aluminium concentration
Range (0,040 – 1,0) mg/l
Spectrophotometric method PN-92/C-04605/02
17 Water, Water intended for human consumption Nitrite concentration
Range (0,040 – 0,74) mg/l
Spectrophotometric method PN-EN 26777:1999
18 Water, Water intended for human consumption Turbidity
Range (0,10 – 50) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
19 Water, Water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 + Ap1:2015-06 pkt.7
20 Water, Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
21 Water, Water intended for human consumption Electrical conductivity
Range (148 – 2500) μS/cm
Conductometric method PN-EN 27888:1999
22 Water, Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (33 – 700) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
23 Water, Water intended for human consumption Ammonium ion concentration
Range (0,030 – 2,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
24 Water, Water intended for human consumption Nitrate concentration
Range (0,40 – 60) mg/l
Spectrophotometric method PN-82/C-04576/08
25 Water, Water intended for human consumption Total iron concentration
Range (0,010 – 5,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+ Ap1:2016-06
26 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
27 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
Microbiology Laboratory for Water Testing
28 Water Total viable count at 22oC Plate method (pour plate) PN-EN ISO 6222:2004
29 Water Count of coliform bacteria, thermotolerant and presumptive coliforms, Escherichia coli Membrane filtration method PN-ISO 9308-1:1999
30 Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
31 Water Escherichia coli count Membrane filtration method PB-PMW-3 wydanie 1 z dnia 16.03.2020 r.
32 Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04
33 Water Escherichia coli count Membrane filtration method PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04

Reference standards (29)

PB-PMW-3 wydanie 1 z dnia 16.03.2020 r.
PN-73/C-04576.14
PN-77/C-04584
PN-82/C-04576/08
PN-86/C-04573.01
PN-92/C-04605/02
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007 + Ap. 1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5815-1:2019-12 IR-PCHŚ-120/PO-6 wyd. nr 1 z dnia 16.03.2020
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 rozdz. 8 + Ap.1:2010: + Ap.2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 + Ap1:2015-06 pkt.7
PN-EN ISO 7899-2:2004
PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11 z wył. p. 5.4
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+ Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9308-1:1999